Laserfiche WebLink
Approvals— E.T.L. and C.G.A. listed, efficiency rating verified by C,.S.A., components <br />S bonded for grounding to meet safety standards for servicing required by U.L., Standard Standard Standard <br />C.S.A. and National and Canadian Electrical Codes <br />ARI Ratings — Ratings in accordance with ARI Standard 340/360 -93 and certified to ARI Standard Standard Standard <br />• <br />Compressors — Reciprocating type <br />Compressors — Copeland® Compliant Scroll'" type for high efficiency "H" Models <br />Outdoor Coil Construction — Slab type, angled design of coil (331 inherently protects <br />it from possible hail damage <br />Refrigeration System — Consists of: compressors, condenser coils and direct drive <br />fans, evaporator coil and belt drive blowers, expansion valves, high capacity driers, <br />high pressure switches, low pressure switches, full refrigerant charge, crankcase Standard Standard Standard <br />heaters, freezestats (prevent coil freeze -up during low ambient operation or loss of <br />air), independent refrigerant circuits (allows staging) <br />Warranty — Limited five years compressors, limited one year all other components, <br />see limited warranty certificate included with unit for details <br />FEATURES <br />LGA MODELS <br />Compressors — Reciprocating type <br />Item <br />Approvals — E.T.L. /C.G.A. certified as combination heating /cooling unit for outdoor <br />installation, efficiency rating verified by C,.S.A., bonded for grounding to meet <br />safety standards for servicing required by E.T.L. /C.G.A. and National and Canadian <br />Electrical Codes <br />ARI Ratings — Ratings in accordance with ARI Standard 340/360-93 and certified to ARI Standard <br />Outdoor Coil Construction — Slab type, angled design of coil (33`•) inherently protects <br />it from possible hail damage <br />Fan and Limit Controls — Factory installer', 90 second fan "on" time delay, dual limit <br />controls (primary and secondary) with fixed temperature setting <br />Warranty — Limited ten years heat exchanger, limited five years compressors, one year <br />all other components, see limited warranty certificate Included with unit for details <br />Item <br />Approvals E.T.L. and C.G.A. listed, efficiency rating verified by C,.S.A., components <br />bonded for grounding to meet safety standards for servicing required by U.L., <br />C.S.A. and National and Canadian Electrical Codes <br />Compressors — Advanced reciprocating type for high efficiency <br />Defrost Control — Furnished on Integrated Modular Control, defrost control provides <br />a defrost cycle, if needed, every 30 or 60 or 90 minutes (adjustable) of compressor <br />"on" time at outdoor coil temperature below 32 "F (0 "C). Pressure switch mounted <br />on outdoor coil vapor line terminates defrost cycle. <br />Outdoor Coll Construction — Formed <br />Refrigeration System — Consists of: compressors, outdoor coils and direct drive fans, <br />Indoor coil and belt drive blowers, check and expansion valves (indoor and out- <br />door), high capacity driers, high pressure switches, low pressure switches, revers- <br />ing valves, defrost control, full refrigerant charge, crankcase heaters, freezestats <br />(prevent coil freeze -up during low ambient operation or loss of air), Independent <br />refrigerant circuits (allows staging) <br />Warranty — Limited five years compressors, limited one year all other components, <br />see limited warranty certificate Included with unit for details <br />"S" Models <br />Standard <br />Standard <br />LGA180 1 LGA210 1 LGA240 <br />Standard <br />"S" Models <br />Compressors — Copeland® Compliant Scroll'" type for high efficiency "1 Models <br />Standard <br />Standard <br />Standard <br />Standard <br />ARI Ratings — Ratings in accordance with ARI Standard 340/360-93 and certified to ARI Standard <br />"S" Models "S" Models <br />"H" Models "F(" Models <br />Standard Standard <br />Standard <br />Standard <br />Standard <br />LHA180 1 LHA240 <br />Standard <br />Standard <br />Standard Standard <br />Standard <br />Standard <br />Standard Standard <br />"S" Models "S" Models <br />"H" Models "H" Models <br />Standard Standard <br />Standard Standard <br />Heat Exchanger — Tubular construction, aluminized steel, life cycle tested Standard Standard Standard <br />Heating System — Aluminized steel inshot burners, direct spark ignition, <br />electronic flame sensor, redundant automatic dual gas valve with manual Standard Standard Standard <br />shut-off, induced draft blower, flame rollout switch <br />Refrigeration System — Consists of: compressors, condenser coil and direct drive <br />fans, evaporator coil and belt drive blowers, expansion valves, high capacity dri- <br />ers, high pressure switches, low pressure switches, full refrigerant charge, crank- Standard Standard Standard <br />case heaters, freozestats (prevent coil freeze -up during low ambient operation or <br />loss of air) independent refrigerant circuits (allows staging) <br />Standard <br />FEATURES <br />LMA MODELS <br />"H" Models "H" Models <br />Standard Standard <br />Standard Standard <br />Standard Standard <br />L Series 180- 210 -240 / Page 3 ► <br />