Laserfiche WebLink
Enter- <br />W e t <br />Wet <br />Bulb <br />Temper - <br />Total <br />Air <br />Volume <br />Outdoor Air Temperature Entering Condenser Coil <br />85°F (29 "Cl <br />95°F 135 °C) <br />105'F (41`C) <br />115°F (46 °C) <br />Total <br />Cooling <br />Capacity <br />Com• <br />pressor <br />W <br />Input <br />Sensible <br />To Total <br />Ratio (SIT) <br />Total <br />CTotal <br />Cepacity <br />Com• <br />pressor <br />Watts <br />Input <br />Sensible <br />To Total <br />R `S�TI <br />Total <br />Cooling <br />Capacity <br />Com• <br />pressor <br />Sensible <br />To Total <br />Ratio <br />Total <br />Cooling <br />Capacity <br />Com• <br />pressor <br />Watts <br />Input <br />Sensible <br />To Total <br />Ratio <br />Dry Bulb <br />BS/bTl <br />D•y <br />B Ib) <br />L/s <br />cfm <br />kW <br />Btuh <br />24 <br />27`6F 80"F <br />85°F <br />1 29`6 <br />kW <br />Btuh <br />° F <br />75 `6 <br />24 <br />8 0 °F <br />27`6 <br />85 ° F <br />29 C <br />kW <br />Btuh <br />Watts <br />Input <br />5°F <br />7 24'C <br />8OF85°F <br />Na <br />'t <br />kW <br />Btuh <br />°F <br />75°F <br />80`F85"F <br />27 C <br />29 C <br />63`F <br />117.2 °C) <br />3020 <br />6400 <br />70.7 <br />241,300 <br />15,720 <br />.70 <br />.84 <br />.98 <br />67.4 <br />229,900 <br />17,800 <br />.70 <br />.86 <br />.99 <br />63.9 <br />218,000 <br />20,130 <br />.71 <br />.87 <br />1.00 <br />60.1 <br />205,200 <br />22,820 <br />.72 <br />.90 <br />1.00 <br />3775 <br />8000 <br />73.5 <br />250,800 <br />15,840 <br />.75 <br />.92 <br />1.00 <br />70.0 <br />239,000 <br />17,910 <br />.76 <br />.94 <br />1.00 <br />66.5 <br />69.0 <br />226,800 <br />235,600 <br />20,270 <br />20,410 <br />.78 <br />.85 <br />.96 <br />1.00 <br />1.00 <br />1.00 <br />62.8 <br />65.4 <br />214,200 <br />223,300 <br />22,940 <br />23,100 <br />.80 <br />.87 <br />.98 <br />1.00 <br />1.00 <br />1.00 <br />4530 <br />9600 <br />75.9 <br />259,000 <br />15,940 <br />.81 <br />.99 <br />1.00 <br />72.5 <br />247,500 <br />18,030 <br />.83 <br />1.00 <br />1.00 <br />67 F <br />(19.4 °C) <br />3020 <br />6400 <br />75.1 <br />256,300 <br />15,910 <br />.54 <br />.67 <br />.80 <br />71.6 <br />244,300 <br />17,980 <br />.55 <br />.68 <br />.82 <br />67.9 <br />231,600 <br />20,350 <br />.55 <br />.69 <br />.84 <br />64.0 <br />218,300 <br />23,030 <br />.65 <br />.70 <br />.86 <br />3775 <br />8000 <br />77.6 <br />264,700 <br />16,010 <br />.58 <br />.73 <br />.89 <br />73.9 <br />76.6 <br />252,000 <br />257,900 <br />18,090 <br />18,160 <br />.68 <br />.62 <br />.74 <br />.80 <br />.91 <br />.98 <br />70.0 <br />71.6 <br />238,900 <br />244,400 <br />20,440 <br />20,520 <br />.58 <br />.62 <br />.75 <br />.82 <br />.93 <br />.99 <br />66.0 <br />67,5 <br />225,100 <br />230,200 <br />23,120 <br />23,230 <br />.69 <br />.63 <br />.77 <br />.85 <br />.95 <br />1.00 <br />4530 <br />9600 <br />79.4 <br />270,800 <br />16,090 <br />.61 <br />.79 <br />.96 <br />71`F <br />(21.7`C) <br />__ <br />3020 <br />6400 <br />80.2 <br />273,50`3 <br />16,120 <br />.41 <br />.53 <br />.65 <br />76.5 <br />260,900 <br />18,200 <br />.40 <br />.53 <br />.66 <br />72.6 <br />247,600 <br />20,590 <br />.40 <br />.53 <br />.66 <br />68.4 <br />233,500 <br />23,270 <br />.39 <br />.54 <br />.68 <br />3775 <br />8000 <br />82.4 <br />281,300 <br />16,240 <br />.42 <br />.56 <br />.71 <br />78,7 <br />268,400 <br />18,310 <br />.42 <br />.57 <br />.72 <br />74.5 <br />254,300 <br />20,690 <br />.41 <br />.67 <br />.73 <br />70.3 <br />239,800 <br />23,390 <br />.41 <br />.58 <br />.75 <br />4530 <br />9600 <br />84.1 <br />286,800 <br />16,300 <br />.43 <br />.60 <br />.76 <br />80.1 <br />273300 <br />18,390 <br />.43 <br />.61 <br />.78 <br />75.9 <br />259,000 <br />20,780 <br />.43 <br />.61 <br />.80 <br />71.6 <br />244,200 <br />23,470 <br />.43 <br />.62 <br />.82 <br />5 "F80 °F <br />Total 0 Total Total Outcloor Air Temperature Entering Condenser Coil <br />Enter- Total 65 °F (18 "C) 75 "F 124 "C) 85 °F 129°C) 95 °F (35 °C) <br />Wet Air Sensible Sensible Sensible Sensible <br />Volume Total Corn- To Total Total Com• To Total Total Corn- To Total Total Corn- Bulb Cooling pressor Ratio (S /TI Coolbig pressor Ra io (S /T) Cooling pressor Ratio IS /T) Cooling To Total <br />Temper- Capacity Motor -' Ca �acity Ca rucit acct <br />Ca pressor Ratio IS /T) <br />Dry Bulb Motor Dry Bulb y Motor Dry Bulb p y Motor D y Bulb <br />ature Watts Watts Watts Watts , <br />L/s cfm kW Btuh Input 75 "F 80"F 85 "F kW Btuh Input 75 "F 80 "F 85 "F kW Stull Input 75 °F 80"F 85'F kW Btuh Input 75'F 80'F 85`F <br />24'C 27`C 29 C _24`C 27'C 29 C 24`0 27'C, 9 <br />63 °F 3020 6400 39.6' 135,100 6260 .65 .80 .94 37.7 128,500 7030 .66 .81 .96 35.6 121,500 7940 .66 .82 .97 33.5 114,300 8980 .66 .83 .99 <br />(17.2 °C) 3775 8000 41.1 140,400 6310 .70 .88 1.00 39.1 133,400 7090 .71 .89 1.00 37.0 126,300 7990 .72 .91 1,00 34.8 118,900 9040 .73 .93 1,00 <br />4530 9600 42.4 144,600 6360 .76 .95 1.00 40.4 137,700 7140 .77 .97 1.00 38.2 130,500 8050 .78 .98 1.00 36.1 123,200 9100 .80 1.00 1.00 <br />67`F 3020 6400 42.1 143,500 6340 .52 .63 .76 40.0 136,500 7120 .52 .63 .77 37.8 129,100 8030 .51 .64 .78 35.6 121,600 9080 .51 .64 .79 <br />(19.4 °C) 3775 8000 43.4 148,100 6390 .55 .68 .84 41.3 140,800 7170 .55 .68 .85 39.1 133,300 8080 .54 .69 .87 36.8 125,600 9130 .54 .70 .89 <br />4530 9600 44.4 151,600 6420 .57 .74 .92 42.2 144,100 7210 .57 .75 .94 40.0 136,400 8120 .58 .76 .95 37.7 128,500 9170 .58 .77 .97 <br />71°F 3020 6400 44.8 152,700 6440 .40 .50 .61 42.6 145,400 7220 .39 .50 .61 40.4 137,800 8140 .38 .50 .61 38.1 129,900 9190 .37 .49 .62 <br />(21.7"C) 3775 8000 46.1 157,300 6490 .41 .53 .66 r 43.9 149,800 7270 .40 .53 .66 41.6 141,800 8190 .39 .53 .67 39.2 133,700 9250 .39 .53 .68 <br />4530 9600 47.0 160,400 6530 .42 .56 .71 44.8 152 700 7310 .41 .56 .72 42.4 144,700 8230 .41 .57 .73 39.9 136,200 9280 .40 .57 .75 <br />Outdoor Air Temperature Entering Condenser Coil <br />Enter- Total 85`F (29 'CI 95 "F (35 "CI 105"F (41`C) 115 "F (46 C) <br />Ina Air Total Total Total Total Sensible To Sensible To Sensible Sensible <br />Wlt Volume Cooling Com- To Total Cooling Com- To Total Cooling <br />Com- To Total Cooling Com• To Total <br />Temper- Capacity pressor RDr B S b 1 Cu mcity pressor otor D B I Capacity Motorr Re <br />Dry BSIh i Capacity pressor Ra lo Bulb) <br />Motor <br />Motor <br />ature Watts Watts Watts Watts <br />L/s cfm kW Btuh Input 75 "F "F 85`F kW Btuh Input 75 "F BO'F 85`F kW Btu Input 75`F 80"1:85"F 5 "F kW Btutr Input 75 °F 80'F 851 <br />24`6 27`C 29 C 24 27 29 C 24`0 27`029 0 24'0 27•C 29 C <br />63 F 3020 6400 70.4 240,200 18,600 .68 .82 .96 66.1 225,700 20,050 .69 .84 .98 61.7 210,500 21,600 .70 .87 1.00 57.2 195,300 23,180 .72 .90 1.00 <br />(17.2 "C) 3775 8000 73.2 249,600 18,880 .73 .90 1.00 68.8 234,600 20,390 .74 .92 1.00 64.2 219,100 22,000 .77 .95 1.00 59.7 203,700 23,660 .79 .97 1.00 <br />4530 9600 75.4 257,300 19,100 .78 .96 1.00 71.0 242,100 20,680 .80 .98 1.00 66.5 226,900 22,370 .83 1.00 1.00 62.1 211,900 24,130 .86 1.00 1.00 <br />67 °F 3020 6400 75.1 256,200 19,060 .53 .65 .78 70.5 240,500 20,620 .53 .66 .80 65.8 224,500 22,250 .54 .68 .83 61.0 208,200 23,920 .54 .69 .86 <br />(19.4 "C) 3775 8000 77.5 264,400 19,310 .56 .70 .86 72.7 248,100 20,900 .57 .72 .88 67.8 231,400 22,580 .57 .74 .91 62.9 214,600 24,280 .58 .76 .94 <br />4530 9600 79.2 270,200 19,470 .59 .76 .93 74.3 253,600 21,100 .60 .78 .95 69.3 236,500 22,820 .61 .80 .98 64.3 219,300 24,560 .62 .83 1.00 <br />71 °F 3020 6400 80.2 273,600 19,560 .40 .51 .63 75.3 257,100 21,230 .40 .52 .64 70.4 240,300 22,990 .39 .52 .65 65.5 223,400 24,770 .39 .53 .67 <br />(21.7 "C) 3775 8000 82.5 281,600 19,800 .41 .55 .68 77.5 264,600 21,500 .41 .65 .70 72.4 247,200 23,300 .41 .56 .71 67,2 229,400 25,110 .40 .57 .74 <br />4530 9600 84.1 287,100 19,940 .42 .58 .73 79.0 269,700 21,690 .42 .59 .75 73.8 251,800 23,510 .42 .60 .78 68.5_233,600 25,350 .42 .61 .81 <br />Outdoor Air Temperature Entering Condenser Coil <br />Enter- Total 65 "F (18 "C) 75"F (24 "C) 85 "F 129 "C) 95 "F 135°6) <br />We t Total <br />Air Sensible To Sensible T Sensible Tot Sensible <br />Volume Corn• To Total Com• To Total Com• To Total Com• To Total <br />Bulb Temper- Capacity pressor RDtioBiSbTI Capacity Mot D r lo SbT) Capacity pressor Ratio Bulb <br />) Capacity pressor <br />t <br />oor RD toBulbi <br />ature Watts -�--' Watts ry Bulb Watts ry Watts y <br />L/s cfm kW Btuh Input 75 24`0 2T C °F80"F85 °F kW Btuh Input ;ITN kW Btuh Input 75 24 ` C 27`6 <br />29 C 1 k Btuh Input 27`6 29 0 <br />80°F85°F <br />0 4' 6 27 C 2 9 <br />63 °F 3020 6400 38.8 132,400 7990 .67 .80 f .92 36.7 125,100 8490 .67 .81 .94 34.3 117,000 9120 .68 .83 .96 31.8 108,500 9830 .69 .84 .98 <br />(17.2 "C) 3775 8000 40.3 137,600 8060 .71 .86 .99 38.1 130,000 8600 .72 .88 1.00 35.6 121,600 9260 .73 .90 1.00 33.1 112,800 10,000 .74 .92 1.00 <br />4530 9600 41,5 141,700 8110 .76 .92 1.00 39.2 133,900 8680 .77 .94 1.00 36.8 125,400 9360 .78 .96 1.00 34.1 116,500 10,140 .80 .98 1.00 <br />67 °F 3020 6400 41.4 141,100 8110 .54 .65 .76 39.1 133,300 8670 .53 .65 .77 36.6 124,800 9350 .53 .65 .79 33.9 115,800 10,110 .53 .66 .80 <br />)19.4°C) 3775 8000 42.8 145,900 8170 .56 .69 .83 40.4 137,800 8760 .56 .69 .84 37.7 128,800 9470 .56 .70 .136 35.0 119,400 10,250 .56 .72 .89 <br />4530 9600 43.7 149,200 8210 .58 .73 .89 41.3 140,800 8820 .58 .75 .91 38.6 131,700 9550 .69 .76 .93 35.8 122,100 10,350 .59 .78 .95 <br />71'F 3020 6400 44.1 150,400 8230 .42 .52 .62 41.7 142,200 8850 .41 .52 .62 39.1 133,400 9590 .40 .51 .63 36.3 123,900 10,410 .39 .51 .64 <br />(21.7 °C) 3775 8000 45.5 155,200 8290 .42 .54 .66 43.0 146,600 8940 .41 .54 .67 40.2 137,300 9700 .41 .54 .68 37,4 127,600 10,540 .40 .55 .69 <br />4530 9600 46.5 158,500 8330 .43 .57 .71 43.8 149,600 9000 .42 .57 .72 41.1 140,100 9780 .42..57 .74 38.1 130,000 10,630 .41 .58 .75 <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />LCA /LGA240H - HIGH EFFICIENCY - TWO COMPRESSORS OPERATING <br />COOLING RATINGS <br />NOTE - For Tomperaturos and Capacities not shown in tables, soo bulletin - Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. <br />LCA /LGA240S -- STANDARD EFFICIENCY - TWO COMPRESSORS OPERATING <br />OT All valuus art, g ass Guinn: (us a id do not loch du !damn apurator coil blow motor he I deduction. <br />LCA /LGA240S - STANDARD EFFICIENCY - ALL COMPRESSORS OPERATING <br />- Alt values uu gross cap 0 (ttos and do not inc! ulu uvaporator coil bit wor motor ho 1 cluduction. <br />LCA /LGA240H - HIGH EFFICIENCY - ALL COMPRESSORS OPERATING <br />All valuus are u oss cupacitius and do not include uvapurator cul blowur motor ho 1 durhrction. <br />LCA /LGA <br />L Series 180 - 210 -240 / Page 29 ► <br />