Laserfiche WebLink
TUKWILA PUBLIC SCHOOLS AUXILIARY PROJECTS PACKAGE #1 <br />TRANSPORTATION BUILDING <br />ABBREVIATIONS <br />AFF <br />APPROX <br />ARCH <br />BLDG <br />BLKG <br />BO <br />CJ <br />CL <br />CLR <br />COL <br />CONC <br />CONT <br />D <br />DEMO <br />DTL <br />DIA <br />DIM <br />DN <br />DS <br />DWG <br />E <br />(E), EXIST <br />EJ <br />EL <br />ELEC <br />EQ <br />EQUIP <br />FCIO <br />FIN <br />FO <br />FOIC <br />FT <br />GA <br />GALV <br />GWB <br />GYP BD <br />H <br />HORIZ <br />HR <br />HT <br />HVAC <br />ID <br />INSUL <br />L <br />ABOVE FINISHED FLOOR <br />APPROXIMATE <br />ARCHITECTURAL <br />BUILDING <br />BLOCKING <br />BOTTOM OF <br />CONTROL JOINT <br />CENTERLINE <br />CLEAR <br />COLUMN <br />CONCRETE <br />CONTINUOUS, CONTINUE <br />DEEP, DEPTH <br />DEMOLISH, DEMOLITION <br />DETAIL <br />DIAMETER <br />DIMENSION <br />DOWN <br />DOWNSPOUT <br />DRAWING <br />EAST <br />EXISTING <br />EXPANSION JOINT <br />ELEVATION <br />ELECTRIC, ELECTRICAL <br />EQUAL <br />EQUIPMENT <br />FURNISHED BY CONTRACTOR/ <br />INSTALLED BY OWNER <br />FINISH, FINISHED <br />FACE OF <br />FURNISHED BY OWNER/ <br />INSTALLED BY CONTRACTOR <br />FOOT, FEET <br />GAGE, GAUGE <br />GALVANIZED <br />GYPSUM WALL BOARD <br />GYPSUM BOARD <br />HIGH <br />HORIZONTAL <br />HOUR <br />HEIGHT <br />HEATING, VENTILATING, <br />AND AIR CONDITIONING <br />INSIDE DIAMETER <br />INSULATE, INSULATION <br />LONG <br />REFERENCE SYMBOLS <br />BUILDING SECTION INDICATOR <br />AX.xx <br />SECTION INDICATOR <br />AX.xx <br />SECTION DETAIL INDICATOR <br />ENLARGED DETAIL INDICATOR <br />COLUMN GRIDLINE INDICATOR <br />FLAGNOTE <br />DRAWING REVISION INDICATOR <br />MAX <br />MECH <br />MEZZ <br />MFR <br />MIN <br />MISC <br />MTL <br />N <br />NIC <br />NO <br />NTS <br />OC <br />OH <br />OD <br />OPNG <br />OPP <br />ORD <br />PERP <br />PLYWD <br />PL <br />PR <br />PT <br />R <br />RD <br />REINF <br />REQD <br />REV <br />RM <br />RO <br />S <br />SHT <br />SHTHG <br />SIM <br />SPEC <br />SQ <br />SS <br />STL <br />STOR <br />STRUCT <br />SUSP <br />T &G <br />TO <br />TYP <br />UON <br />VERT <br />W/ <br />W/O <br />WD <br />MAXIMUM <br />MECHANICAL <br />MEZZANINE <br />MANUFACTURE, MANUFACTURE <br />MINIMUM, MINUTE <br />MISCELLANEOUS <br />METAL <br />NORTH <br />NOT IN CONTRACT <br />NUMBER <br />NOT TO SCALE <br />ON CENTER <br />OVERHEAD <br />OUTSIDE DIAMETER <br />OPENING <br />OPPOSITE <br />OVERFLOW ROOF DRAIN <br />PERPENDICULAR <br />PLYWOOD <br />PROPERTY LINE <br />PAIR <br />PAINT, POINT, PRESSURE TREATED <br />RADIUS, RISER <br />ROOF DRAIN, ROAD <br />REINFORCED, REINFORCING <br />REQUIRED <br />REVISED, REVISION <br />ROOM <br />ROUGH OPENING <br />SOUTH <br />SHEET <br />SHEATHING <br />SIMILAR <br />SPECIFICATION <br />SQUARE <br />STAINLESS STEEL <br />STEEL <br />STORAGE <br />STRUCTURAL <br />SUSPENDED <br />TONGUE AND GROOVE <br />TOP OF <br />TYPICAL <br />UNLESS OTHERWISE NOTED <br />VERTICAL <br />WEST, WIDE <br />WITH <br />WITHOUT <br />WOOD <br />XX' -XX" <br />XXXXXXX <br />ELEVATION INDICATOR <br />Q _ MATCH LINE <br />SEE SHEET AX.XX <br />MATCHLINE INDICATOR <br />GENERAL NOTES <br />1. <br />NOTHING IN THE DRAWINGS SHALL BE CONSTRUED TO PERMIT AN <br />INSTALLATION IN VIOLATION OF APPLICABLE CODES. ALL WORK <br />PERFORMED UNDER THIS CONTRACT SHALL BE IN FULL <br />ACCORDANCE WITH THE LATEST RULES, REGULATIONS, <br />RESTRICTIONS, REQUIREMENTS, AND CODES OF THE GOVERNING <br />JURISDICTIONS. <br />2. THE DRAWINGS ARE INTENDED TO DESCRIBE THE OVERALL SCOPE <br />OF WORK. CONTRACTORS SHALL FIELD VERIFY EXISTING <br />CONDITIONS AND DIMENSIONS ON THE PROJECT AND ALERT THE <br />ARCHITECT TO ANY CONFLICTS BEFORE BEGINNING WORK. <br />3. DO NOT SCALE DRAWINGS. THE CONTRACTOR SHALL USE <br />DIMENSIONS SHOWN ON THE DRAWINGS AND ACTUAL FIELD <br />MEASUREMENTS. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES <br />WITH DRAWINGS. <br />4. CONTRACTOR TO VERIFY ALL DIMENSIONS, PROPERTY LINES, <br />MEASUREMENTS AND CONDITIONS IN THE FIELD BEFORE BEGINNING <br />WORK. ANY DISCREPANCIES, ERRORS OR OMISSIONS TO BE <br />BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY. <br />5. TYPICAL WALL SECTIONS, FINISHES, AND DETAILS ARE NOT <br />INDICATED EVERYWHERE THEY OCCUR ON PLANS, ELEVATIONS, AND <br />SECTIONS. REFER TO DETAILED DRAWINGS. <br />6. DETAILED AND /OR LARGER SCALE DRAWINGS TAKE PRECEDENCE <br />OVER GENERAL AND SMALLER SCALE DRAWINGS. <br />7. GENERALLY PLAN DIMENSIONS SHOWN ARE TO FINISH OPENING, <br />FACE OF CONCRETE, FACE OF STUD AND FINISH FACE OF WALL, <br />UNLESS NOTED OTHERWISE. <br />8. UNLESS OTHERWISE NOTED, ALL ANGLES TO BE RIGHT ANGLES, ALL <br />LINES WHICH APPEAR PARALLEL ARE TO BE PARALLEL, AND ALL <br />ITEMS WHICH APPEAR CENTERED ARE TO BE CENTERED. <br />CONTRACTOR TO BE RESPONSIBLE FOR MAINTAINING ALL LINES <br />TRUE, LEVEL, PLUMB, AND SQUARE. <br />9. CONTRACTOR TO COMPLY WITH CIVIL, LANDSCAPE, STRUCTURAL, <br />MECHANICAL AND ELECTRICAL NOTES. <br />10. MECHANICAL AND ELECTRICAL SUBCONTRACTORS SHALL OBTAIN ALL <br />REQUIRED PERMITS. <br />11. <br />THE CONTRACTOR SHALL VERIFY ALL ROUGH -IN DIMENSIONS FOR <br />THE EQUIPMENT. <br />12. ALL ATTACHMENTS, CONNECTIONS, AND FASTENINGS OF ANY <br />NATURE ARE TO BE PROPERLY AND PERMANENTLY SECURED IN <br />CONFORMANCE WITH THE BEST PRACTICES OF THE BUILDING <br />INDUSTRY. DRAWINGS SHOW ONLY SPECIAL REQUIREMENTS TO <br />ASSIST THE CONTRACTOR AND DO NOT SHOW EVERY DETAIL. <br />13. CAULKING AND SEALANTS. USE PRIMERS AS REQUIRED BY <br />MANUFACTURER. BACKING RODS OR TAPE AS RECOMMENDED BY <br />MANUFACTURER AND PER SPECIFICATIONS. <br />14. VAPOR BARRIERS. CONTINUOUS AND APPROVED VAPOR BARRIERS <br />SHALL BE INSTALLED ON THE HEATED SIDE OF ALL THERMAL <br />INSULATION INSTALLED AS INDICATED. SEAL ALL EDGES. <br />15. CONTRACTOR AT BEGINNING OF WORK TO FLUSH ALL ROOF DRAINS <br />TO CONFIRM IN WORKING ORDER. AT CONCLUSION OF WORK <br />CONTRACTOR TO TEST ALL ROOF DRAINS TO CONFIRM IN WORKING <br />ORDER AND TIGHT LINES THROUGHOUT BUILDING AND PROVIDE <br />CONFIRMATION REPORT TO OWNER. <br />16. CONTRACTOR SHALL VERIFY LOCATION OF ALL EXISTING UTILITIES <br />AND PROTECT AS REQUIRED PRIOR TO COMMENCEMENT OF WORK. <br />17. CONTRACTOR TO COORDINATE ALL OPERATIONS WITH OWNER, <br />INCLUDING: SITE ACCESS, MATERIALS STORAGE, AND STAGING, <br />INTERRUPTION OF ELECTRICAL AND MECHANICAL SERVICES AND <br />TIMING OF NOISY AND DISRUPTIVE OPERATIONS. CONTRACTOR TO <br />VERIFY SEQUENCE OF WORK WITH OWNER. <br />18. CONTRACTOR TO PROTECT EXISTING FURNISHINGS, FIXTURES, <br />EQUIPMENT AND LANDSCAPING FROM DAMAGE. CONTRACTOR TO <br />REPLACE IN KIND ANY SUCH ITEMS DAMAGED. <br />19. CONTRACTOR SHALL PROTECT ALL ROOF OPENINGS FROM WATER <br />PENETRATION DURING CONSTRUCTION. <br />20. CONTRACTOR SHALL MAINTAIN CURRENT RECORD DRAWINGS FOR <br />ARCHITECT'S PERIODIC REVIEW. <br />21. AS BUILT DRAWINGS ARE BASED ON RECORD DRAWINGS AND MAY BE <br />INCLUDED FOR REFERENCE AS TO THE SCOPE OF WORK ONLY. <br />CONTRACTOR SHALL VISIT SITE PRIOR TO BID, EXAMINE EXISTING <br />CONDITIONS AND INCLUDE ALL DEMOLITION REQUIREMENTS FOR THE <br />SCOPE OF THE PROJECT IN THE CONTRACT SUM. NO ADDITIONAL <br />PAYMENTS WILL BE MADE FOR FAILURE TO OBTAIN ALL REQUIRED <br />INFORMATION AND MAKE KNOWN ANY INACCURACIES. <br />22. THROUGHOUT THE DRAWINGS ARE ABBREVIATIONS THAT ARE IN <br />COMMON USE. THE LIST OF ABBREVIATIONS PROVIDED IS NOT <br />INTENDED TO BE COMPLETE OR REPRESENTATIVE OF CONDITIONS <br />OR MATERIALS USED ON THIS PROJECT. THE ARCHITECT WILL DEFINE <br />THE INTENT OF ANY IN QUESTION. <br />23. INTERIOR PARTITION TYPES ARE GENERALLY KEYED ON <br />ARCHITECTURAL FLOOR PLANS. SEE PARTITION TYPE FOR <br />DESCRIPTIONS. THE FINISH SCHEDULE AUGMENTS THE PARTITION <br />TYPE DESCRIPTION WITH INFORMATION REGARDING MATERIALS AND <br />FINISHES. <br />24. GENERALLY, THE EXISTING ELEMENTS ARE SHOWN WITH LIGHT <br />SCREENED LINES, WHILE NEW OR DEMOLISHED ELEMENTS REQUIRED <br />BY THE PROJECT ARE SHOWN WITH DARK LINES. <br />25. ALL DOOR NUMBERS APPEAR ON THE PLANS EXCEPT WHERE <br />ENLARGED PLANS ARE INDICATED. RELITES ARE NOT SCHEDULED <br />UNLESS THEY ARE ADJACENT TO A DOOR. INDEPENDENT RELITES <br />ARE SHOWN ON INTERIOR ELEVATIONS AND DETAIL KEYS ARE <br />INDICATED THERE. NOTE THAT HOLLOW METAL DOOR SECTIONS <br />ALSO OCCUR AT CERTAIN EXTERIOR ELEVATIONS. <br />26. MATERIAL FINISH CODES WHICH IDENTIFY MATERIAL AND FINISHES <br />THROUGHOUT THE DRAWINGS ARE LISTED ON THE FINISH <br />SCHEDULES. THE SPECIFICATIONS SECTIONS WHICH DEFINE THE <br />MATERIALS ARE REFERENCED. FINISH SCHEDULE INDICATES THE <br />VARIOUS FLOOR, WALL AND CEILING FINISHES IN THE INDIVIDUAL <br />ROOMS INDICATED. REFER TO THE FINISH SCHEDULE NOTES FOR <br />GENERAL FINISH INFORMATION AND WORK. <br />27. DEFINITIONS OF FINISH CEILINGS ARE SHOWN ON THE REFLECTED <br />CEILING PLAN. MATERIAL, DIMENSIONS OF ELEMENTS WITHIN CEILING, <br />AND SPOT ELEVATIONS OF VARIOUS CEILING PLANES ARE SHOWN. <br />LAYOUTS OF LIGHT FIXTURES, MECHANICAL DIFFUSERS, ETC. IN <br />ROOMS WITHOUT CEILINGS ARE SHOWN FOR DESIGN CLARITY ON <br />REFLECTED CEILING PLANS. SEE MECHANICAL AND ELECTRICAL <br />DRAWINGS FOR RESPECTIVE LAYOUTS, COORDINATE AS REQUIRED. <br />28. ROOFING TYPES ARE INDICATED ON THE ROOF LEVEL PLAN AT WHICH <br />THEY OCCUR. THE MATERIAL FINISH CODE (RT) DESIGNATES ROOF <br />TYPE DESCRIPTION. PROVIDE THERMAL ROOF INSULATION AS <br />INDICATED BY ROOFING CODES. <br />N <br />LOCATION MAP <br />SCALE: N.T.S. <br />PROJECT DATA INFORMATION <br />PROJECT DESCRIPTION: <br />NEW ONE STORY TRANSPORTATION SUPPORT BUILDING <br />LOCATED ON THE SW CORNER OF SITE AT EXISTING <br />IMPERVIOUS SURFACE. ADJUSTMENT OF BUS PARKING AND <br />STAFF PARKING. LANDSCAPE MODIFICATION AROUND EXISTING <br />SITE PERIMETER. <br />SITE ADDRESS: <br />12801 E. MARGINAL WAY SOUTH TUKWILA, WA 98168 <br />PARKING LOT AT CORNER OF SOUTH 128TH STREET AND EAST <br />MARGINAL WAY. A PORTION OF NE 1/4 OF THE NW 1/4 OF SEC.15, <br />TWN. 23 N., RGE.04 E. W.M. CITY OF TUKWILA, KING COUNTY <br />WASHINGTON. <br />ASSESSOR'S PARCEL NO: <br />238420 -0010 <br />LEGAL DESCRIPTION: <br />LOT B OF CITY OF TUKWILA SHORT PLAT NO 90 -4 -SS <br />RECORDING NO 9101140403, RECORDS OF KING <br />COUNTY WASHINGTON. <br />JURIDICTION: CITY OF TUKWILA <br />APPLICABLE CODES: <br />2015 INTERNATIONAL BUILDING CODE <br />2015 INTERNATIONAL MECHANICAL CODE <br />2015 INTERNATIONAL FIRE CODE <br />2015 INTERNATIONAL PLUMBING CODE <br />AND ALL RELATED STANDARDS AND STATE AMENDMENTS <br />2015 WASHINGTON STATE ENERGY CODE <br />ZONING DESIGNATION: NCC <br />CONSTRUCTION TYPE: V -B <br />OCCUPANCY TYPE: A -2, B, 5 -1 <br />LOT AREA: 1.41 ACRES/ 61440 SF <br />PROPOSED TOTAL FLOOR AREA: 2,530 SF <br />MAX BUILDING HEIGHT: 35' -0" <br />PROJECT TEAM <br />OWNER TUKWILA SCHOOL DISTRICT <br />4640 S 144TH STREET <br />TUKWILA, WA 98168 <br />CONTACT: JEFF FEENEY, PROJECT MANAGER <br />TEL: (206) 979 - 9370 <br />FAX: N/A <br />ARCHITECT ROLLUDA ARCHITECTS <br />105 S MAIN ST, SUITE 323 <br />SEATTLE WA, 98104 <br />CONTACT: ALEXANDER CLARK, AIA <br />ALEX .CLARK @ROLLUDAARCHITECTS.COM <br />TEL: (206) 624 -4222 <br />FAX: (206) 624 -4226 <br />CIVIL AHBL, INC <br />1200 6TH AVENUE, SUITE 1620 <br />SEATTLE WA, 98101 <br />CONTACT: CHARLIE PALMER, DOUG TAFF <br />CPALMER @AHBL.COM <br />TEL: (206) 267 -2425 <br />FAX: (206) 267 -2429 <br />MECHANICAL TRESWEST ENGINEERS <br />2702 S 42ND ST #301, TACOMA, WA 98409 <br />CONTACT: REID HERRON <br />RSH @TRESWEST.COM <br />TEL: (253) 472 -3300 <br />FAX: (253) 363 -9402 <br />ELECTRICAL TRESWEST ENGINEERS <br />2702 S 42ND ST #301, TACOMA, WA 98409 <br />CONTACT: SCOTT FELTON <br />SKF @TRESWEST.COM <br />TEL: (253) 472 -3300 <br />FAX: (253) 363 -9402 <br />STRUCTURAL REID MIDDLETON <br />728 134TH ST SW, SUITE 200, EVERETT, WA 98204 <br />CONTACT: PAUL CROCKER <br />PCROCKER @REIDMIDDLETON.COM <br />TEL: (425) 741.3800 <br />FAX: (425) 741.3900 <br />LANDSCAPE AHBL, INC <br />1200 6TH AVENUE, SUITE 1620 <br />SEATTLE WA, 98101 <br />CONTACT: MEREDITH SESSIONS <br />MSESSIONS @AHBL.COM <br />TEL: (206) 267 -2425 <br />FAX: (206) 267 -2429 <br />DRAWING INDEX - TRANSPORTATION BUILDING SITE <br />GENERAL <br />TG0.01 COVER SHEET <br />T1 TOPOGRAPHIC SURVEY <br />CIVIL <br />TC3.0 CIVIL SITE PLAN <br />ARCHITECTURAL <br />TA1.01 SITE PLAN PROPOSED <br />TA2.01 FLOOR PLAN <br />TA2.02 ROOF PLAN <br />TA3.01 EXTERIOR ELEVATIONS <br />TA4.01 BUILDING SECTIONS <br />LANDSCAPE <br />TL1.0 PLANTING PLAN <br />TL2.0 <br />TL2.1 <br />TL3.0 <br />LANDSCAPE DETAILS <br />IRRIGATION DETAILS <br />IRRIGATION PLAN <br />ELECTRICAL <br />LTG.01 SITE LIGHTING CALCULATION <br />n <br />2 <br />m <br />z <br />CUP UPDATES <br />rolluda architects <br />architecture '1 terior o 3 n <br />105 S. Main Street Suite 323 <br />Seattle, WA 98104 <br />t: 206 - 624 -4222 <br />f: 206 - 624 -4226 <br />6250 <br />REGISTERED <br />ARC IITT <br />Alex E. Rolluda <br />STATE OF WASHINGTON <br />12801 EAST MARGINAL WAY SOUTH, TUKWILA, WA 98168 <br />w <br />z <br />0 <br />REVISION DATE <br />Design: AC <br />Drawn: JL, JC <br />Checked: AC <br />Project No. 331 -16 -01 <br />Issuance <br />CUP UPDATES <br />Date: 4/10/2017 <br />Drawing Title <br />COVER SHEET <br />Drawing Number <br />TG0.01 <br />G0.01 COVER.DWG <br />4/11/2017 10:14 AM <br />COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC <br />