TUKWILA PUBLIC SCHOOLS AUXILIARY PROJECTS PACKAGE #1
<br />TRANSPORTATION BUILDING
<br />ABBREVIATIONS
<br />AFF
<br />APPROX
<br />ARCH
<br />BLDG
<br />BLKG
<br />BO
<br />CJ
<br />CL
<br />CLR
<br />COL
<br />CONC
<br />CONT
<br />D
<br />DEMO
<br />DTL
<br />DIA
<br />DIM
<br />DN
<br />DS
<br />DWG
<br />E
<br />(E), EXIST
<br />EJ
<br />EL
<br />ELEC
<br />EQ
<br />EQUIP
<br />FCIO
<br />FIN
<br />FO
<br />FOIC
<br />FT
<br />GA
<br />GALV
<br />GWB
<br />GYP BD
<br />H
<br />HORIZ
<br />HR
<br />HT
<br />HVAC
<br />ID
<br />INSUL
<br />L
<br />ABOVE FINISHED FLOOR
<br />APPROXIMATE
<br />ARCHITECTURAL
<br />BUILDING
<br />BLOCKING
<br />BOTTOM OF
<br />CONTROL JOINT
<br />CENTERLINE
<br />CLEAR
<br />COLUMN
<br />CONCRETE
<br />CONTINUOUS, CONTINUE
<br />DEEP, DEPTH
<br />DEMOLISH, DEMOLITION
<br />DETAIL
<br />DIAMETER
<br />DIMENSION
<br />DOWN
<br />DOWNSPOUT
<br />DRAWING
<br />EAST
<br />EXISTING
<br />EXPANSION JOINT
<br />ELEVATION
<br />ELECTRIC, ELECTRICAL
<br />EQUAL
<br />EQUIPMENT
<br />FURNISHED BY CONTRACTOR/
<br />INSTALLED BY OWNER
<br />FINISH, FINISHED
<br />FACE OF
<br />FURNISHED BY OWNER/
<br />INSTALLED BY CONTRACTOR
<br />FOOT, FEET
<br />GAGE, GAUGE
<br />GALVANIZED
<br />GYPSUM WALL BOARD
<br />GYPSUM BOARD
<br />HIGH
<br />HORIZONTAL
<br />HOUR
<br />HEIGHT
<br />HEATING, VENTILATING,
<br />AND AIR CONDITIONING
<br />INSIDE DIAMETER
<br />INSULATE, INSULATION
<br />LONG
<br />REFERENCE SYMBOLS
<br />BUILDING SECTION INDICATOR
<br />AX.xx
<br />SECTION INDICATOR
<br />AX.xx
<br />SECTION DETAIL INDICATOR
<br />ENLARGED DETAIL INDICATOR
<br />COLUMN GRIDLINE INDICATOR
<br />FLAGNOTE
<br />DRAWING REVISION INDICATOR
<br />MAX
<br />MECH
<br />MEZZ
<br />MFR
<br />MIN
<br />MISC
<br />MTL
<br />N
<br />NIC
<br />NO
<br />NTS
<br />OC
<br />OH
<br />OD
<br />OPNG
<br />OPP
<br />ORD
<br />PERP
<br />PLYWD
<br />PL
<br />PR
<br />PT
<br />R
<br />RD
<br />REINF
<br />REQD
<br />REV
<br />RM
<br />RO
<br />S
<br />SHT
<br />SHTHG
<br />SIM
<br />SPEC
<br />SQ
<br />SS
<br />STL
<br />STOR
<br />STRUCT
<br />SUSP
<br />T &G
<br />TO
<br />TYP
<br />UON
<br />VERT
<br />W/
<br />W/O
<br />WD
<br />MAXIMUM
<br />MECHANICAL
<br />MEZZANINE
<br />MANUFACTURE, MANUFACTURE
<br />MINIMUM, MINUTE
<br />MISCELLANEOUS
<br />METAL
<br />NORTH
<br />NOT IN CONTRACT
<br />NUMBER
<br />NOT TO SCALE
<br />ON CENTER
<br />OVERHEAD
<br />OUTSIDE DIAMETER
<br />OPENING
<br />OPPOSITE
<br />OVERFLOW ROOF DRAIN
<br />PERPENDICULAR
<br />PLYWOOD
<br />PROPERTY LINE
<br />PAIR
<br />PAINT, POINT, PRESSURE TREATED
<br />RADIUS, RISER
<br />ROOF DRAIN, ROAD
<br />REINFORCED, REINFORCING
<br />REQUIRED
<br />REVISED, REVISION
<br />ROOM
<br />ROUGH OPENING
<br />SOUTH
<br />SHEET
<br />SHEATHING
<br />SIMILAR
<br />SPECIFICATION
<br />SQUARE
<br />STAINLESS STEEL
<br />STEEL
<br />STORAGE
<br />STRUCTURAL
<br />SUSPENDED
<br />TONGUE AND GROOVE
<br />TOP OF
<br />TYPICAL
<br />UNLESS OTHERWISE NOTED
<br />VERTICAL
<br />WEST, WIDE
<br />WITH
<br />WITHOUT
<br />WOOD
<br />XX' -XX"
<br />XXXXXXX
<br />ELEVATION INDICATOR
<br />Q _ MATCH LINE
<br />SEE SHEET AX.XX
<br />MATCHLINE INDICATOR
<br />GENERAL NOTES
<br />1.
<br />NOTHING IN THE DRAWINGS SHALL BE CONSTRUED TO PERMIT AN
<br />INSTALLATION IN VIOLATION OF APPLICABLE CODES. ALL WORK
<br />PERFORMED UNDER THIS CONTRACT SHALL BE IN FULL
<br />ACCORDANCE WITH THE LATEST RULES, REGULATIONS,
<br />RESTRICTIONS, REQUIREMENTS, AND CODES OF THE GOVERNING
<br />JURISDICTIONS.
<br />2. THE DRAWINGS ARE INTENDED TO DESCRIBE THE OVERALL SCOPE
<br />OF WORK. CONTRACTORS SHALL FIELD VERIFY EXISTING
<br />CONDITIONS AND DIMENSIONS ON THE PROJECT AND ALERT THE
<br />ARCHITECT TO ANY CONFLICTS BEFORE BEGINNING WORK.
<br />3. DO NOT SCALE DRAWINGS. THE CONTRACTOR SHALL USE
<br />DIMENSIONS SHOWN ON THE DRAWINGS AND ACTUAL FIELD
<br />MEASUREMENTS. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES
<br />WITH DRAWINGS.
<br />4. CONTRACTOR TO VERIFY ALL DIMENSIONS, PROPERTY LINES,
<br />MEASUREMENTS AND CONDITIONS IN THE FIELD BEFORE BEGINNING
<br />WORK. ANY DISCREPANCIES, ERRORS OR OMISSIONS TO BE
<br />BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY.
<br />5. TYPICAL WALL SECTIONS, FINISHES, AND DETAILS ARE NOT
<br />INDICATED EVERYWHERE THEY OCCUR ON PLANS, ELEVATIONS, AND
<br />SECTIONS. REFER TO DETAILED DRAWINGS.
<br />6. DETAILED AND /OR LARGER SCALE DRAWINGS TAKE PRECEDENCE
<br />OVER GENERAL AND SMALLER SCALE DRAWINGS.
<br />7. GENERALLY PLAN DIMENSIONS SHOWN ARE TO FINISH OPENING,
<br />FACE OF CONCRETE, FACE OF STUD AND FINISH FACE OF WALL,
<br />UNLESS NOTED OTHERWISE.
<br />8. UNLESS OTHERWISE NOTED, ALL ANGLES TO BE RIGHT ANGLES, ALL
<br />LINES WHICH APPEAR PARALLEL ARE TO BE PARALLEL, AND ALL
<br />ITEMS WHICH APPEAR CENTERED ARE TO BE CENTERED.
<br />CONTRACTOR TO BE RESPONSIBLE FOR MAINTAINING ALL LINES
<br />TRUE, LEVEL, PLUMB, AND SQUARE.
<br />9. CONTRACTOR TO COMPLY WITH CIVIL, LANDSCAPE, STRUCTURAL,
<br />MECHANICAL AND ELECTRICAL NOTES.
<br />10. MECHANICAL AND ELECTRICAL SUBCONTRACTORS SHALL OBTAIN ALL
<br />REQUIRED PERMITS.
<br />11.
<br />THE CONTRACTOR SHALL VERIFY ALL ROUGH -IN DIMENSIONS FOR
<br />THE EQUIPMENT.
<br />12. ALL ATTACHMENTS, CONNECTIONS, AND FASTENINGS OF ANY
<br />NATURE ARE TO BE PROPERLY AND PERMANENTLY SECURED IN
<br />CONFORMANCE WITH THE BEST PRACTICES OF THE BUILDING
<br />INDUSTRY. DRAWINGS SHOW ONLY SPECIAL REQUIREMENTS TO
<br />ASSIST THE CONTRACTOR AND DO NOT SHOW EVERY DETAIL.
<br />13. CAULKING AND SEALANTS. USE PRIMERS AS REQUIRED BY
<br />MANUFACTURER. BACKING RODS OR TAPE AS RECOMMENDED BY
<br />MANUFACTURER AND PER SPECIFICATIONS.
<br />14. VAPOR BARRIERS. CONTINUOUS AND APPROVED VAPOR BARRIERS
<br />SHALL BE INSTALLED ON THE HEATED SIDE OF ALL THERMAL
<br />INSULATION INSTALLED AS INDICATED. SEAL ALL EDGES.
<br />15. CONTRACTOR AT BEGINNING OF WORK TO FLUSH ALL ROOF DRAINS
<br />TO CONFIRM IN WORKING ORDER. AT CONCLUSION OF WORK
<br />CONTRACTOR TO TEST ALL ROOF DRAINS TO CONFIRM IN WORKING
<br />ORDER AND TIGHT LINES THROUGHOUT BUILDING AND PROVIDE
<br />CONFIRMATION REPORT TO OWNER.
<br />16. CONTRACTOR SHALL VERIFY LOCATION OF ALL EXISTING UTILITIES
<br />AND PROTECT AS REQUIRED PRIOR TO COMMENCEMENT OF WORK.
<br />17. CONTRACTOR TO COORDINATE ALL OPERATIONS WITH OWNER,
<br />INCLUDING: SITE ACCESS, MATERIALS STORAGE, AND STAGING,
<br />INTERRUPTION OF ELECTRICAL AND MECHANICAL SERVICES AND
<br />TIMING OF NOISY AND DISRUPTIVE OPERATIONS. CONTRACTOR TO
<br />VERIFY SEQUENCE OF WORK WITH OWNER.
<br />18. CONTRACTOR TO PROTECT EXISTING FURNISHINGS, FIXTURES,
<br />EQUIPMENT AND LANDSCAPING FROM DAMAGE. CONTRACTOR TO
<br />REPLACE IN KIND ANY SUCH ITEMS DAMAGED.
<br />19. CONTRACTOR SHALL PROTECT ALL ROOF OPENINGS FROM WATER
<br />PENETRATION DURING CONSTRUCTION.
<br />20. CONTRACTOR SHALL MAINTAIN CURRENT RECORD DRAWINGS FOR
<br />ARCHITECT'S PERIODIC REVIEW.
<br />21. AS BUILT DRAWINGS ARE BASED ON RECORD DRAWINGS AND MAY BE
<br />INCLUDED FOR REFERENCE AS TO THE SCOPE OF WORK ONLY.
<br />CONTRACTOR SHALL VISIT SITE PRIOR TO BID, EXAMINE EXISTING
<br />CONDITIONS AND INCLUDE ALL DEMOLITION REQUIREMENTS FOR THE
<br />SCOPE OF THE PROJECT IN THE CONTRACT SUM. NO ADDITIONAL
<br />PAYMENTS WILL BE MADE FOR FAILURE TO OBTAIN ALL REQUIRED
<br />INFORMATION AND MAKE KNOWN ANY INACCURACIES.
<br />22. THROUGHOUT THE DRAWINGS ARE ABBREVIATIONS THAT ARE IN
<br />COMMON USE. THE LIST OF ABBREVIATIONS PROVIDED IS NOT
<br />INTENDED TO BE COMPLETE OR REPRESENTATIVE OF CONDITIONS
<br />OR MATERIALS USED ON THIS PROJECT. THE ARCHITECT WILL DEFINE
<br />THE INTENT OF ANY IN QUESTION.
<br />23. INTERIOR PARTITION TYPES ARE GENERALLY KEYED ON
<br />ARCHITECTURAL FLOOR PLANS. SEE PARTITION TYPE FOR
<br />DESCRIPTIONS. THE FINISH SCHEDULE AUGMENTS THE PARTITION
<br />TYPE DESCRIPTION WITH INFORMATION REGARDING MATERIALS AND
<br />FINISHES.
<br />24. GENERALLY, THE EXISTING ELEMENTS ARE SHOWN WITH LIGHT
<br />SCREENED LINES, WHILE NEW OR DEMOLISHED ELEMENTS REQUIRED
<br />BY THE PROJECT ARE SHOWN WITH DARK LINES.
<br />25. ALL DOOR NUMBERS APPEAR ON THE PLANS EXCEPT WHERE
<br />ENLARGED PLANS ARE INDICATED. RELITES ARE NOT SCHEDULED
<br />UNLESS THEY ARE ADJACENT TO A DOOR. INDEPENDENT RELITES
<br />ARE SHOWN ON INTERIOR ELEVATIONS AND DETAIL KEYS ARE
<br />INDICATED THERE. NOTE THAT HOLLOW METAL DOOR SECTIONS
<br />ALSO OCCUR AT CERTAIN EXTERIOR ELEVATIONS.
<br />26. MATERIAL FINISH CODES WHICH IDENTIFY MATERIAL AND FINISHES
<br />THROUGHOUT THE DRAWINGS ARE LISTED ON THE FINISH
<br />SCHEDULES. THE SPECIFICATIONS SECTIONS WHICH DEFINE THE
<br />MATERIALS ARE REFERENCED. FINISH SCHEDULE INDICATES THE
<br />VARIOUS FLOOR, WALL AND CEILING FINISHES IN THE INDIVIDUAL
<br />ROOMS INDICATED. REFER TO THE FINISH SCHEDULE NOTES FOR
<br />GENERAL FINISH INFORMATION AND WORK.
<br />27. DEFINITIONS OF FINISH CEILINGS ARE SHOWN ON THE REFLECTED
<br />CEILING PLAN. MATERIAL, DIMENSIONS OF ELEMENTS WITHIN CEILING,
<br />AND SPOT ELEVATIONS OF VARIOUS CEILING PLANES ARE SHOWN.
<br />LAYOUTS OF LIGHT FIXTURES, MECHANICAL DIFFUSERS, ETC. IN
<br />ROOMS WITHOUT CEILINGS ARE SHOWN FOR DESIGN CLARITY ON
<br />REFLECTED CEILING PLANS. SEE MECHANICAL AND ELECTRICAL
<br />DRAWINGS FOR RESPECTIVE LAYOUTS, COORDINATE AS REQUIRED.
<br />28. ROOFING TYPES ARE INDICATED ON THE ROOF LEVEL PLAN AT WHICH
<br />THEY OCCUR. THE MATERIAL FINISH CODE (RT) DESIGNATES ROOF
<br />TYPE DESCRIPTION. PROVIDE THERMAL ROOF INSULATION AS
<br />INDICATED BY ROOFING CODES.
<br />N
<br />LOCATION MAP
<br />SCALE: N.T.S.
<br />PROJECT DATA INFORMATION
<br />PROJECT DESCRIPTION:
<br />NEW ONE STORY TRANSPORTATION SUPPORT BUILDING
<br />LOCATED ON THE SW CORNER OF SITE AT EXISTING
<br />IMPERVIOUS SURFACE. ADJUSTMENT OF BUS PARKING AND
<br />STAFF PARKING. LANDSCAPE MODIFICATION AROUND EXISTING
<br />SITE PERIMETER.
<br />SITE ADDRESS:
<br />12801 E. MARGINAL WAY SOUTH TUKWILA, WA 98168
<br />PARKING LOT AT CORNER OF SOUTH 128TH STREET AND EAST
<br />MARGINAL WAY. A PORTION OF NE 1/4 OF THE NW 1/4 OF SEC.15,
<br />TWN. 23 N., RGE.04 E. W.M. CITY OF TUKWILA, KING COUNTY
<br />WASHINGTON.
<br />ASSESSOR'S PARCEL NO:
<br />238420 -0010
<br />LEGAL DESCRIPTION:
<br />LOT B OF CITY OF TUKWILA SHORT PLAT NO 90 -4 -SS
<br />RECORDING NO 9101140403, RECORDS OF KING
<br />COUNTY WASHINGTON.
<br />JURIDICTION: CITY OF TUKWILA
<br />APPLICABLE CODES:
<br />2015 INTERNATIONAL BUILDING CODE
<br />2015 INTERNATIONAL MECHANICAL CODE
<br />2015 INTERNATIONAL FIRE CODE
<br />2015 INTERNATIONAL PLUMBING CODE
<br />AND ALL RELATED STANDARDS AND STATE AMENDMENTS
<br />2015 WASHINGTON STATE ENERGY CODE
<br />ZONING DESIGNATION: NCC
<br />CONSTRUCTION TYPE: V -B
<br />OCCUPANCY TYPE: A -2, B, 5 -1
<br />LOT AREA: 1.41 ACRES/ 61440 SF
<br />PROPOSED TOTAL FLOOR AREA: 2,530 SF
<br />MAX BUILDING HEIGHT: 35' -0"
<br />PROJECT TEAM
<br />OWNER TUKWILA SCHOOL DISTRICT
<br />4640 S 144TH STREET
<br />TUKWILA, WA 98168
<br />CONTACT: JEFF FEENEY, PROJECT MANAGER
<br />TEL: (206) 979 - 9370
<br />FAX: N/A
<br />ARCHITECT ROLLUDA ARCHITECTS
<br />105 S MAIN ST, SUITE 323
<br />SEATTLE WA, 98104
<br />CONTACT: ALEXANDER CLARK, AIA
<br />ALEX .CLARK @ROLLUDAARCHITECTS.COM
<br />TEL: (206) 624 -4222
<br />FAX: (206) 624 -4226
<br />CIVIL AHBL, INC
<br />1200 6TH AVENUE, SUITE 1620
<br />SEATTLE WA, 98101
<br />CONTACT: CHARLIE PALMER, DOUG TAFF
<br />CPALMER @AHBL.COM
<br />TEL: (206) 267 -2425
<br />FAX: (206) 267 -2429
<br />MECHANICAL TRESWEST ENGINEERS
<br />2702 S 42ND ST #301, TACOMA, WA 98409
<br />CONTACT: REID HERRON
<br />RSH @TRESWEST.COM
<br />TEL: (253) 472 -3300
<br />FAX: (253) 363 -9402
<br />ELECTRICAL TRESWEST ENGINEERS
<br />2702 S 42ND ST #301, TACOMA, WA 98409
<br />CONTACT: SCOTT FELTON
<br />SKF @TRESWEST.COM
<br />TEL: (253) 472 -3300
<br />FAX: (253) 363 -9402
<br />STRUCTURAL REID MIDDLETON
<br />728 134TH ST SW, SUITE 200, EVERETT, WA 98204
<br />CONTACT: PAUL CROCKER
<br />PCROCKER @REIDMIDDLETON.COM
<br />TEL: (425) 741.3800
<br />FAX: (425) 741.3900
<br />LANDSCAPE AHBL, INC
<br />1200 6TH AVENUE, SUITE 1620
<br />SEATTLE WA, 98101
<br />CONTACT: MEREDITH SESSIONS
<br />MSESSIONS @AHBL.COM
<br />TEL: (206) 267 -2425
<br />FAX: (206) 267 -2429
<br />DRAWING INDEX - TRANSPORTATION BUILDING SITE
<br />GENERAL
<br />TG0.01 COVER SHEET
<br />T1 TOPOGRAPHIC SURVEY
<br />CIVIL
<br />TC3.0 CIVIL SITE PLAN
<br />ARCHITECTURAL
<br />TA1.01 SITE PLAN PROPOSED
<br />TA2.01 FLOOR PLAN
<br />TA2.02 ROOF PLAN
<br />TA3.01 EXTERIOR ELEVATIONS
<br />TA4.01 BUILDING SECTIONS
<br />LANDSCAPE
<br />TL1.0 PLANTING PLAN
<br />TL2.0
<br />TL2.1
<br />TL3.0
<br />LANDSCAPE DETAILS
<br />IRRIGATION DETAILS
<br />IRRIGATION PLAN
<br />ELECTRICAL
<br />LTG.01 SITE LIGHTING CALCULATION
<br />n
<br />2
<br />m
<br />z
<br />CUP UPDATES
<br />rolluda architects
<br />architecture '1 terior o 3 n
<br />105 S. Main Street Suite 323
<br />Seattle, WA 98104
<br />t: 206 - 624 -4222
<br />f: 206 - 624 -4226
<br />6250
<br />REGISTERED
<br />ARC IITT
<br />Alex E. Rolluda
<br />STATE OF WASHINGTON
<br />12801 EAST MARGINAL WAY SOUTH, TUKWILA, WA 98168
<br />w
<br />z
<br />0
<br />REVISION DATE
<br />Design: AC
<br />Drawn: JL, JC
<br />Checked: AC
<br />Project No. 331 -16 -01
<br />Issuance
<br />CUP UPDATES
<br />Date: 4/10/2017
<br />Drawing Title
<br />COVER SHEET
<br />Drawing Number
<br />TG0.01
<br />G0.01 COVER.DWG
<br />4/11/2017 10:14 AM
<br />COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC
<br />
|