City of Tukwila
My WebLink
|
Help
Search Tips
|
About
|
Sign Out
Browse
Search
PP - 2646 SOUTHCENTER MALL - ZUMIEZ - PERMITS AND PLANS
COT-City
>
City Clerk
>
Fire Marshal Records
>
Permits and Plans
>
PP - 2646 SOUTHCENTER MALL - ZUMIEZ - PERMITS AND PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/10/2023 5:41:25 PM
Creation date
1/5/2023 12:46:27 PM
Metadata
Fields
Template:
Fire Marshal Records
Record No (example Fire Permit is "16-F-108")
19-F-034, 08-F-246, 19-S-031, 08-S-220
Fire Record Type
Permits Plans and Other Records
Parcel No
9202470010
House Number
2646
Street (example *32* for 32nd)
SOUTHCENTER MALL
Business Name
ZUMIEZ
Notes (example *grandmother's hill*)
SCANNED #042-012 (INTERNAL USE ONLY)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
• Flexible sprinkler hose bends shall not exceed the maximum radius permitted by <br />the listing. <br />• Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. <br />• Extend sprinkler protection to all combustible concealed spaces. <br />• Comply with NFPA 13 obstruction tables. <br />• All valves controlling the water supply for automatic sprinkler systems and <br />waterflow switches on all sprinkler systems shall be electrically supervised. <br />• All interior control valves shall be readily accessible, labeled and located not <br />more than 6 ft. above the floor. <br />• Comply with obstructed/non-obstructed construction rules for sprinkler head <br />placement. <br />• Sprinkler heads spaced closer than 6 ft. apart must be baffled. <br />• Modifications involving 20 or more sprinkler heads require hydrostatic test and <br />system isolation if necessary. <br />• For dry pipe and double interlock preaction systems in addition to the standard <br />hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 <br />hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the <br />24 hours shall be corrected. These conditions apply to all sprinkler piping <br />exposed as necessary to accomplish the permitted scope of work. <br />• These conditions apply to all sprinkler piping exposed as necessary to <br />accomplish the permitted scope of work. <br />All code references are NFPA 13, 2016 Edition. <br />
The URL can be used to link to this page
Your browser does not support the video tag.