Loading...
HomeMy WebLinkAboutPermit D2000-242 - BOEING EMPLOYEES CREDIT UNION (BECU) - OFFICE• BECU 12770 GATEWAY DRIVE D2000 -242 City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Parcel No: 27] 600 -0075 Address: 12770 GATEWAY DR Suite No: Location: Category: AOFF Type: DEVPERM Zoning: C /LI DEVELOPMENT PERMIT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PEPIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Corgi st Type: Occupancy: Gas/Elec.: UBC: Unit:: 001 Fire Protection: Setbacks: North: .0 South: .0 East: .0 West: Water: TLIKWILA Sewer: SEPTIC Wetlands: Slope'_: Y Streams: Contractor License No: SELLEC *372ND OCCUPANT OWNER CONTACT CONTRACTOR BOEING'EMPLOYEE'S CREDIT UNION 12770 GATEWAY DR, TLIKWILA WA 98167 BOEING EMPLOYEES CREDIT UN PO BOX 97050, SEATTLE WA 981249750 CLAIRE MADSEN .12770 GATEWAY DR, TUKWILA WA 98168 SELLEN CONSTR C0 INC PO BOX 9970, SEATTLE, WA 98109 (206) 431 -3670 Permit No: D2000 -242 Status. ISSUED Issued: 08/11/2000 Expires: 02/07/2001 OFFICE 1997 SPRINT'LERS /AFA .0 Phone: Phone: (206)439 -5961 Phone:. 206 -S12 -513] Phone: 206 -682 -7770 *kk :k *k**•.kk *4 k k: k* ***'k•k•k•k•k**4k- kk•.kk;k:k : k• . i'A•kk **kkkA!** . k• kk • kkk***:k**k** : k•*** • kk**•k*** Permit Description BUILD TWO WALLS TO CREATE PRIVATE OFFICE ON FOURTH FLOOR * kk: k: 4*• k*•* k**• k*******k**** k• k•. kkkkk*k... k A.•k k*• k•k• kk* kk• kk k•*• A* k• k• k: k* k• k* :kk :k ****•k*•k *•k Construction V a l u a t i o n : $ 5, 500.00 PUBLIC WORTS 'PERMITS: *(Water Meter Perm i is L i s t e d Separate) Eng. Appr: Curb Cut, /Ac :ce .s/ S i dewa 1 k /:'SS : N Fire.Loop Hydrant: N No: Flood Control Zone: N Hauling: N Start Time: Land Altering: N Cut: Landscape Irrigation: N Moving'Oversi:ed Load: N Start Time:- End Time Sanitary 'Side; Sewer• N No Sewer Main EXt'ension N Private: N Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N *:k•k **A* *** * *** **k * *•k****k*• k• k**** :...k ***k* * :4 :l:k•fr k. kk*****• k: k• k• k* . kk . kt . •kk•k:kk:k•A** *:k•k**k *k TOTAL DEVELOPMENT PERMIT FEES: $ 211.16 *** ** ***k*** * *•k*k****•* **k*** * **4* *** * * * .* :k'k*,*** *•k•k****.k: ** **:kk****•k ** ******•k**** *k' Permit Center Authorized Signature: - a vicK. Date: e:-1I1:kD • Si'ze(in) .00 End Time Fill: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development permit. giVieldid4e6 Signature.: Print, Name.: reOMGC.'a il Date: T h i s permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. U U 0 N D u) ICJ W O` g CO 3 w z �' : 2 j O 13 W , u O w Z co I= — 0� z NEW Address: Suite: Tenant: IFype: IJE:Vi•'ERM Parcel #: 271600 - -0075 CITY OF TUKWILA Permit No: 02000 -242 Status: ISSUED Applied: 07/24/2000 Issued: 08/11/2000 • k•k:.•`• k• k• k• A: l ••A•A•k'k•A•k•k'k'k•k•kA *4.*kA *A k• k• k• A• k•AA•k•A•k•kA : A• k• k• k' k• k• k• k: kkA AA• kL Ak•k•k•A Permit Conditions: 1. ',No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. All construction to be done ':in conformance with approved plans and ``requirements of the Uniform B u i l d i n g Code (1997 Edition) as amended Uniform Mechanical Code ( 1997 Edition) and Washington State Energy Code (1997 Edition) Va)i of Permit. The issuance of a permit or approval of plans, spe - r if icati :ons, and computation: shall : not be ;con - " to 'be .a permit for; or an approval of, any violation of any o f;j the _ , prov i s i ons of the building code or of any other ,'.ord i nance of the jurisdiction. No permit 'presuming, : to „ give e authority to'viol,ate' er cancel the provisions of ; :,thi•s- coder! sha 1 -1 be v a l i d . El ectr Ical�, ppermi ts. shall be obtained through the Washington State Division of Labor and industries and all electrical wor';k gwi l l inspected by that agency (248 6630) Ai.l, work shall be under, separate permiti ssued, by; the�eity of Tukwila:. VENT,ILATION IS'',REQUIf2EIJ•'F FOR , ALL NEW p ROOMS AND SPACES OF .C)F.'` E:XI STING F3UIL DthGs IN 'CONFORMANCE E.` WITH THE UNIFORM BUILDING CODE AND THE WASHINGTON STATE VENTILATION AND INDOOR AIR j QQUAL I T Y•, CODE, CHAPTER 51-13 WAC. re L i U ' CO ILI LL, W O t g Q N � p w z �`. m co ;0 H w w . I I O' • til O F. Z Project Name/Tenant: •G. v- Existing use: El Retail El Restaurant ❑ Multi- family Warehouse El Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel Office El School /College /University ❑ Other Value of Construction: 0 5, 500 -- Site Address: 1, /, �- ����� ` City State /Zip: "! . TUVAA t-A- cFl,? Tax Parcel Number: 2 (Co n - 004,5 Property Owner: Existing fire protection features: sprinklers Erautomatic fire alarm ❑ none ❑ other (specify) Building Square Feet: 1 4 Qi 7- 77 5 existing Area of Construction: (sq. ft.) 1 410 rir Phone: Address: City State /Zip: Fax #: Contractor: 5 ellevr Co vi,s t P hone: lo (a - cp4 Z -1 14 0 Street Address: 225 i l.� N o Seat t Cit State /Zip: elo y Fax #: lot., - 425 - 52o I. Architect: Phone: Street Address: City State /Zip: Fax #: Engineer: Phone: Street Address: City State /Zip: Fax #: Contact Person: L t ta.,C, ILA 4- t -4 Phone: 2D(o - 2)IZ • e_ Street Address: 12.910 ci Tr✓v\rs-r Pre- . Tt) tc -u..) fl.d City State /Zip: 6 11? 1(08 Fax #: ZoC. -g 12. - 2.7 . 2. Description of work to be done: - 5O /I✓ 7ZV 0 W4 '1 /b G ire kl f 1'Wx 1 y t° al�f v oil eO Irk 'IUt�I,G Existing use: El Retail El Restaurant ❑ Multi- family Warehouse El Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel Office El School /College /University ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑'6ffice ❑ School /College /University ❑ Other Will there be a change of use? ❑ yes Ern° If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? Cl yes ®no Existing fire protection features: sprinklers Erautomatic fire alarm ❑ none ❑ other (specify) Building Square Feet: 1 4 Qi 7- 77 5 existing Area of Construction: (sq. ft.) 1 410 rir Will there be storage of flammable /combustible hazardous material in the building? ❑ yes 17rno Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets D�llce Data�`lra� Apppctaj�tlllals) CITY OF TUKV1'r` :A Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 ommercial / Multi - Family Tenant Improvement / Alteration Permit Application ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk El Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension ❑ Water Meter /Exempt #• Size(s): 0 Deduct ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: El Miscellaneous CTPERMIT.DOC 1/29/97 Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT REQUEST, FOR PUBLIC' WORKS:SITE/CIVIL PLAN REVIEW :OFTHE'.FOLL'OWING :. (Additional reviews maybe determined.tiy.the•Pablic Works Department) . . • ❑ Flood Control Zone ❑ Hauling ❑ Landscape Irrigation O Private 0 Public O Private 0 Public 0 Water Only gal Schedule: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is Issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. PLEASE SIGN BACK OF APPLICATION FORM 14F{PR MgNATFaltebM Z ~ W re 2 00 W= H CO W WO CO 0 W Z = ZI- W • j U O 0— O F- W I F- H O w Z O • ~ Z I C I Alt j IOW WM BUILDING OWNER OR AUTHORIZED AGENT: SignaturCf 0 Date: /24 / a 0 4 , a ' Z 4 -', 14/A ftag4 Print nam a x s _� ; • P ho a -8l — Address /241-0 C 4TCUa_y Om.., y /$$tale p PvKI.0 /i�A ALL COMMERCIAUMULTI ' WILY TENANT IMPROVEMENT/ ERATION PERMIT APPLICATIONS IIfI� BE SUBMITTED WITH THE F• LOWING: ➢�, ,Aj`.LJDROVIN #C#SzTq.-9E STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, prTRU RAL iNGINEER OR CIVIL ENGINEER ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ 71 Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled 71 • Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. 71 • Vicinity Map showing location of site CI • Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. 71 71 Indicate proposed construction of tenant space or addition and walls being demolished ❑ ❑ Construction details 71 71 Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. 71 SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ 71 Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ CI Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER VALTY OF PERJ BY THE LAWS OF TH STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. CTPERMIT.DOC 1/29/97 2 ~ w tr 00 coo W I I- w 0 LL a D = w Z = zI- W w U D O - 0 I— W w u w z U= O ~ z j;iFM;ter >-1 k;)*1.k*A?,h1t4e:lk k*: 4 f , * Ah k" k 4AkAhk ;4Ld*** A•k,1h4.4k *•k:kk•k.` 4.1.:t:� * z f 1 1`1 C11 rutvw11..A„ �;A 1- EFfS1 1I:T z000 T t.1 - � ► kk' *tA*ititfr* **A.rk;is 4 /' *.tA :Il*A4. *Aie.t• ,'+h k: }•%..A** :1 k7 * :1 k TCtEtil�1P1I1 "itunnk,C:r,r R9aoo An1auni;o 211.16 07/24/00 16;17 Iti Vol c?. nt 14et;•ttxd; 1:111:1: It flot t : 11C:Gi.i Ire i 11. 111:tt Ptya- itii . 1)2000-242 Ct. +gar 1)(:Y PI: P. Ili I)EV11.1.1Pt1114 1 P ifr•r.• I Nor. 271600.--0075 t .f4dtit ess: 127' 1rilifil4c17 1)P, CGrt. 1 I (I?[ : 211.1'.. ►if1 E.r. €rti; 211..1 Tot - it I ALL: Ptit:se 211.:16 Ila.1 anc.e 0i) * a F A tk A A k****. i •A •i..+•• 1k 41. /• ,4 k it •?: k •?. A• k •4 A >ti A t A A• :A A A •A A , .4 i% . ?•• -* * * *' •k ?e • ?; F` :r d fi .l it /. * . I t 4 i facc:t.)11rit Ccdc 1)tl • 14 :Itott1t l• 000/322.100 E1.111..DING -• t•IGl'IRES 1' '-' `,.'1 c)00./34!..t. 030 l'1.1.11.1 r,1.11i(it; - -. NONRES 111.41 0∎'?0j3E16:9 t?4' ' S1 f1TE:.ffU) :1 DING $UF.C:(tf•1tcGE: 4.50 25 » 't r l+A'l;` _, a^ / .71 ic "ka , rw}or• ' 1rt h l Y¢rtrIvi'9, r ra �'' ++ t ; ��'� C R���`t i+ tV . r Y. �l lei F•D���T'�t`�5"�` n , "'��� � !'4�'r1X;e' i I�p".F"3"7Mnt'v°i"s't7r +..1 r.7 Ll) \ U7?n, ? Project: 1 Eirr++qq C ((Nrl �+ Unton /Type of Inspectia �if1c� 1, — u t I C-k111c Addre: 12 110 (la iewr«.t\ br Date called: 1 13 - CC) Special instructions: L ' E Itor .50,.r , Side Wo 6 Date wanted: (- I - IS- CC) .m. p.m. Requester: Phone: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, W A Approved per applicable codes. COMMENTS: Ins INSPECTION RECORD. Retain a copy with permit t I PERMIT NO. (206)431 -3670 Corrections required prior to approval. Date? Po $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: in;,. r_t rr &s.pin„�4 hG vlx:+lis4Y.Lyi nrR,F * Nfirs ti.X}1ira4n._Y .+lr,�ta?1Ufkt' ir. ,,.rtY.iuy,'r.'.�ds.ck a...:'iL,c r .ern +.,.1 L✓w� aF` ue U U g CO to w 0; qq LL <; co CJ ? } 1- 2 H', w U 0 's 0 N, ' 0 I—' I.- U. Of •Z CO , _ T 0 z INSPECTION RECO Retain a copy with permit b 2 Cap 2 al INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION i `' / W D �J 6300 Southcenter Blvd, #100, Tukwila, WA 98188 (206)431- 3670 Project: t UmOr Address: J �� 1'? 1-h (=Art-4e Special instructions: 4 1c.cv* c o h Slc`e— Type of Inspection: rvt 1 ',t ) t I r•C D to called: Date wanted: 11 -- CC) Requester: 1 C (1 Phone: El Approved per applicable codes. Corrections required prior to approval. COMMENTS: C 4 t zieletpx, i‘53,e 01/‹.(C //LC S PA" ( gd 7"a o pO&6" Fist (44._ I Insp 7 $47.00 REINSPECTION FEE REQUIRED. Prior to ins ection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 Receipt No: I Date: W Sr}nY1L14lAS.ri:L.:iu.tG�3tYSaai Wdui }._,i'i4r.lwki;•6 - .4'Yi'I:hRiu.+.Q M.v711r. I.u3 iA'ASVa..L. +..A &.• Y....,Y�: 3�1`.:t' P oject; l r∎ Em,0logee) Coria l i o w - T e of Inspection: l TO Y - r'1 Address: 1 2-i -7o (-7( -Ift, au. Dr D to called: ).a - Special instructions: J L +t F cur, SCt,i er,a Di r l c ' Date wanted: .� i �m_J p • Re9ueste : t--\(..r t 1 INSPECTION RECORD Retain a copy with permit :tM INSPECTION NO. CITY. OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 981 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: . ° ��i�iD74�1� .E0.�`�lf.`i"i�ai�ii� LWEG' .12''. M�:L�t+�a�+�Jt '� ''R':•• ; w.ti�4; o `1n'9:Ar7:.C�1'i:•YYd/�1Y.niw'� a.�t.5r•H 1, .�i.i.°.;t�rax {. a•r,...,.an..#YY.rr....:.i:.3xz a ov, r:a.ti `v. av:r.:;:.i Q U N u CO LLI 9 w 0, g a ` 0 , � w HO Z I tu 0 N' 0 H w W ? I 0 . w z N ; 2 Ciy of Tukwila Fire Department Thomas P Keefe, Fire Chief TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Retain current-inspection .schedule . Needs shift inspection Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre- Fire: Permits: Approved without correction notice 'Approved with correction notice issued Permit No. 400-'Q `/1- Steven M. Mullet, Mayor Suite. # --A- YY4 )b fi // l i 7- /. Authorized Signature Date FINALAPP.FRM Rev. 2/19/98 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax: 206.575 -4439 'ii O : z 1- V O' 0 N W W' . u.{5 wz pi O z ACTIVITY NUMBER: D2000 -242 DATE: 7 -24 -2000 PROJECT NAME: BOEING EMPLOYEES CREDIT UNION SITE ADDRESS: 12770 GATEWAY DRIVE XX Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # — After Permit Is Issued DEPAR//T..•• M ENTS: � Building D ivision Fire Pre ention 1111 Planning Division Awe 1 -2 ;-0o AUK 1-24- IV14. 1-2-C 'e Public Works IN Structural n Permit Coordinator L IM 41 -2.6-oo DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 7- 25-2000 J I Complete Comments: TUES /THURS ROUTING: Please Route APPROVALS OR CORRECTIONS: (ten days) Approved REVIEWER'S INITIALS: \PRROUTE.DOC 5/99 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Structural Review Required Approved with Conditions Incomplete Not Applicable No further Review Required DUE DATE: 8 -22 -00 is w n REVIEWER'S INITIALS: DATE: Not Approved (attach comments) DATE: CORRECTION DETERMINATION: DUE DATE Approved Ii Approved with Conditions Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: W Fire Department Review - 512 #D2000 -242 Boeing Employee Credit Union - 12770 Gateway Drive Dear Sir: City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief 7/26/00 The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Maintain fire extinguisher coverage throughout. Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) 2. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Obstructions, including storage, shall not be placed in the required width of an exit, except projections as permitted by the Building Code. Exits shall not be obstructed in any manner and shall remain free of any material or matter where its presence would obstruct or render the exit hazardous. (UFC 1203) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (UFC 1207.3) Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207 -1212) Internally illuminated exit signs shall have both bulbs working at all times. (UBC 1003.2.8.4) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 57$4404 • Fax (206) .575-4439 D w 0 Z J uj DD 0 N, D 1- W O CU z ` 0 City of Tukwila Fire Department Page number 2 John W. Rants, Mayor Thomas P. Keefe, Fire Chief Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1) Combustible material shall not be stored in exits or exit enclosures. (UFC 1103.3.2.3) 3. Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) 4. All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1900) (UFC 1001.3) Call the Tukwila Fire Department at 575 -4407 for approval of any system shut down. Have job site address, name and the Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #1900) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575 - 4404 • Fax (206) 5754439 City of Tukwila Fire Department Page number 3 John W. Rants, Mayor Thomas P. Keefe, The Chief Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) 5. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 6. Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 1111.1) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: File dm Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575 -4404 • Fax (206) 5754439 08/11/00 10:01 FAX • 1-11 MMq CiWcAL. SILLIN CONSTRUCTION DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL 227 Westlake Ave. N. PO Box 9970 Seollle, WA 98109 SELLEN ACCT. SELLEN CONSTR CO INC PO BOX 0970 SEATTLE WA 98109 Tel (206( 652.7770 fax 1206( 023.5200 www.sellen.com I certify that the above registration number is true and accurate as a sworn notary in the City of Seattle, State of Washington, County of King. By: F , 1 f At June 1, 2001 . Gary' D Hart Date GENERAL CONTRACTING CONSTRUCTION MANAGEMENT CUSTOMEI SERVICE GROUP 0001 Nu. w 0' J c a uj H Oi` Q Q'y co ;Q 1 'uJ tlll'. O f w p CEILING SYMBOL LEGEND $ IMF 3111201 f FM SEAR I $ memo swam 3 IOW IIM =NCH r MUM IOC= 91111011 DE SEIM= 0_I2.1 _ 1.----...Ienerws mama 2X4 HOME SIC =4 FIXTURE IFEw I0Gi1011 2X4 MIT D ERGBICY LIMN 12 GA. SPLAY WIRE - VERTICLE AT "T' BAR CROSSING TO STRUCTURE ABOVE al 3 I/2' X 25 GAGE STRUT ATTACH ON MAIN RUNNER a 12' -0' O.G. TO STRUCTURE ABOVE 12 GA WIRES EA IN PLANE PURUNNER AT ® 4516 ANGLE TO STRUCTURE ABOVE. 1 90 r,,,pi zs APART 9 12 0. O.G. EAGH WAY 4 WITHIN 4' -0' OF ALL WALLS. QED ACOUSTICAL TILE CEILING "T' BAR GRID NOTE: INSTALL PER 1113C STD. 4T -1812 (0) 1490 WO STANDARDS NO WALE TYR. INTERIOR WALL SECTION ■ STANDARD POOR RELITE ELEVATION rrP. DOOR ELEVATION SITE FLAN VICINITY MAP INDEX OF DRAMINOS LEON_ DESCRIPTION BEACON AVE S. A.I COVER AND DETAILS A.2 GENERAL NOTES, CONSTRUCTION AND REFLECTED CEILING PLAN FURNITURE LAYOUT - 4th FLOOR GENERAL NOTES, CONSTRUCTION AND REFLECTED CEILING PLAN FURNITURE FLOOR PLAN- 4TH FLOOR SCOFF OF WORK BUILDING CLASSIFICATION JUL. 2 7 ntu;) DMSION Address: 12T10 Gateway Drive, Tukwila, WA All that certain real property situate in the City of Tukwila, County of King, State of Washington, Being a portion of Lot 7 as shown on the plat of Gateway Corporate Center, Recorded in Volume 144 of Plats, Pages 23 -25, under recording number 8901230879, records of King County, Washington, and being more particularly described as follows. Beginning at the most Easterly corner of said Lot 7; thence from said point of beginning, along the boundry line of said Lot 7, S41' 46'16 "W 424.58 Feet; Thence from a Tangent that bears N28'15'l4 "E, along the arc of a curve to the left having a radius of 180.50 Feet and a central angle of 76'28'58 ", an Arc length of 240.94 Feet; Thence tangent to the preceding curve N48'13 44"W 250.43 Feet; Thence to the preceding course along the arc of a cuve to the left having a radius of 180.50 feet and a central angle of 46'18'05 ", an Arc length of 145.86 Feet; Thence leaving the Boundary line of said Lot 7, N04'31'49 "W 41.60 Feet; Thence N41'46'16 E Feet; Thence N48'13' 44 "W 31.00 Feet; Thence N16'58'14 "E 333.84 Feet; To the bank of the Duwamish River. at the mean high water line as shown on said plat, thence along the said Bank of the Duwamish River, Easterly and Southerly to the point of Beginning. Contains 350,666 Square Feet (8.05 Acres) of land more or less. 4th rLOOR Build one new office on South ;Nest side of the 4th Floor. With door, hardware and building standard relite assembly. Relocate light fixtures, sprinklers, HVAG and power where necessary for construction. Construction Type: Type 2, F.R. Fully Sprinkler (exist) OCCUPANCY GROUP: 5, Office (exist) APPLICATION CODE: 14.11 UBG with State of Washington Amendments and Tukwila Municiple Code Amendments Seismic: 3 Proposed Use: Office - No Change Land Use Zone: MI Light Industrial Tenant Improvement Approx. Floor Area: Fourth Floor 140 SF Building Sctuare Footage 14.1,235 sc. ft L RED'_ D GAS _. CITY or. - , BUILDING �l t, ECEIVED CITVROPTUKWIo. JUL 2 4 2000 PERMIT CENTER J2OOo 2ij2 '° • 5OE- N CREW T UN ON 1277O ATElAIA ' IVE TUKV'IL.A, IAA 4th TENANT I M1ROVEMENT WALE VARIES OE16NED BY CLAIRE MADSEN X5I31 CLAIRE MADSEN 7/21/00 A•1 J2OOo 2ij2 '° • GENERAL NOTES: KEY FLAN: Ist FOOR TUKVNILA S.E.C.U. Not to sc.ale 1 AU neanu construction mall be built in accordance with the prevailing codes adopted by the City of Tukwila, in ng ADA requirements. 2. Contractor to provide ail safety requirements of State and Gity, provide barriers. signs and warnings, and rmairritce a o safe enviroment for public and workers. 3. Materials and equipment must be kept picked up and stared out of all corridors, foyers and public areas. Ail areas not under construction must be kept free from dust, noise and/or ir.:erference. _ Contractor to verify existing building conditions, 5. All permits necessary for construction will be supplied by the City of Tukrilio. 6_ Contractor Baer erployees Credit Union (BEGG.u.) Protect Marker for clarification of questions that arise or onion that are encountered which are not covered by or are in conflict with the construction documents. i_ All construction shall occur between b:30 PM and 6:50 AM during weekdays and anytime during weekends, unless pre-approved buy the B.i=.JL.U. Project Manager. b. Sequencing and/or phasing o,' work shall be coordinated reit the B.1E.GJU_ Project Manager. comm. i rk .09 anej trade signifies acceptance of the sustrote work as satisfactory. Correct previous work if Mater found unsatisfactory for such purposes. Iretall all products n a workmanlike manner per manufact- urer" dons. Repair existing building surfaces "there dared or changed by new construction or demolition. Remove from site an debris related to the work and clean for occupancy on daily basis. lo_ Approval for parking and storage use must be pre- arranged witti B.E.G.U. Project Manager. 11 Contractor small leave project vacuumed, dusted, glass cleaned and ready for occupancy_ 12. Contractor *oil provide new ceiling tile where necessary, USG 2 %4" OHMI illusion Two/24, Auratone, White, Shadvwline Tapered_ 15. AU wood in the wall shall be of fire retardant materials. I4_ Conduit runs for electrical outlets shall be removed to Panel. IB_ Contactor to provide one marked -up set of as -built drawings prior to final pent . 16_ All work is to be performed under prevailing wage requirements. 17. All finishes to match adjacent existing finishes. Paint to clean Provide New Building Standard Y1aod Door Frame New Hardware fora 45 min. Fire Rated Assembl y. Provide Standard Recite Assembly Stain Frame, Door and Relites to Match Bulding Standard Mali 2 I/2 ", 25 &A. MTL Studs @ 24" O.G. to Bottom of CIg Grid at 8' -6" appePx. Tine "X" GM each side. Match iildg Std finish FLAN A FLOOR FLAN SCALE: I /8"=1 i °Oi' OExistit6 ng? rmain inkler Heads ® Move existing Licht Fixtures, Connect to Existing Circuit 8' -b" typical ceiling height 4 Move existing Smoke Head �l 2' -0" for light fixture FLAN 5 CEILING FLAN SCALE: I/8 'i = I 1 -0'i DRAINING LEGEND EXISTING WALLS TO BE REMOVED NEW MALLS TO 14' HEIGHT EXISTING WALLS TO REMAIN E = Approx. Exist Location R = prox. Relocated Positron N = Approx. New Location FINISHES 1. CARPET F.O.I.C. 2. PAINT - Parker 5420W Eggshell (to match) 5. 2 1/2" RUBBER COVE BASE - Roppe ELECTRICAL PLAN NOTES: ONew 1IOv Receptacle, bldg Std Location Five Locations ONew 4 Port Data Jack / Mud Ring Pull Wire FLAN G ELECTRICAL FLAN SCALE: I/8' I r -0" RECEIVED CITYOFTUKWIIA Jul. 2 4 2000 PERMIT CENTER FLAN D FURNITURE FLAN SCALE: I /8n° I I°On 2 212 -fin' 50E \S E-"F_O 'EES' J\ 0 \ 12170 GATEWAY DRIVE TUKWILA, INA FOURTH FLOOR TENANT IMPROVEMENTS VARIES DEFASNED BY CLAIRE MADSEN DRAM BY GAM 1/21/00 A•2 2/2