Loading...
HomeMy WebLinkAboutPermit 0851 - McCann Construction - Project 247 - Storage and OfficeThis record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. m: McCann Construction 950 Andover Park East RECORDS DIGITAL D- ) EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION Page Code Exemption = 8rlef E plainatoty Desclriptim Statuteftle The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals' social security Personal Information — numbers are redacted to protect those Social Security Numbers individuals' privacy pursuant to 5 U.S.C. sec. 5 U.S.C. sec. 2,3 DR1 Generally — 5 U.S.C. sec. 552(a), and are also exempt from disclosure 552(a); RCW 552(a); RCW under section 42.56.070(1) of the Washington 42.56.070(1) 42.56.070(1) State Public Records Act, which exempts under the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit Personal Information — expiration dates, or bank or other financial RCW DR2 Financial Information — account numbers, which are exempt from 42.56.230(5) RCW 42.56.230(4 5) disclosure pursuant to RCW 42.56.230(5), except when disclosure is expressly required by or governed by other law. ADDRESS 8013 Perimeter Road So. Seattle, Wash. 98108 PHONE 762 -2555 NAME OF BUILDER McCann Construction STATE LICENSE TAX NO. C-178-12495 ADDRESS 8013 Perimeter Road So. Seattle, Wash. 98108 PHONE 762 -2555 INSPECTION RECORD FOOTINGS BUILDING PERMIT VOID IF WORK IS NOT COMMENCED IN 120 DAYS 1/21/76 ESTIMATED VALUE COMPLETED WORK $ 8,000. 00 FOUNDATION PERMIT FEE $ 44.00 FRAMING PLAN CHECK FEE $ 28.60 LATE PERMIT FEE $ TOTAL FEE $ 72.60 CONST. III — N GROUP OCCUPANCY F -2 DnrE ISSUED 5/21/76 ZONE "' ONE CM EXPIRATION DAZE FINAL FIRE SPRINKLERS REQUIRED MAX. OCC. LOAD MI Yes U No LOCATION OF WORK / NUMBER & STREET LOT OWNER DESCRIPTION OF WORK: CITY 0 TUKWILA BUILDING DEPARTMENT 6230 Southcenter Blvd. �,- Tukwila, Washington 98067 Phone: (206) 242 -2177 950 Andover Park East BLOCK SUBDIVISION McCann Construction CALL FOR INSPECTION BEFORE WORK IS CONCEALED OR POURING CONCRETE PHONE 242-2177 FINAL INSPECTION BEFORE OCCUPANCY LS/Z. lL R L 'i A C KX SK�Ehr Tenant Improvement - Storage Facilities for Owner (McCann) THIS PERMIT DOES NOT AUTHORIZE ANY WORK IN PUBLIC RIGHT-OF-WAY OR ON UTILITY EASEMENTS. SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, VENTILATING OR AIR CONDITIONING. I HEREBY CERTIFY THAT NO WORK IS TO BE DONE EXCEPT AS DESCRIBED ABOVE AND IN APPROVED PLANS AND SPECIFICATIONS AND THAT ALL WORK IS TO CONFORM TO TUKWILA CODES AND ORDINANCES. APPLICANT t� 'N C C41 es-s -r/f S 1,I(T/Dkl' BY SUBJECT TO COMP INFORMATION BUILDING DIRECTOR BY Proj. 247 PERMIT NUMBER No 851 ITH THE ORDINANCES OF HE CITY OF TUKWILA AND ITH, THIS PERMIT ' I j S GRA TED. -t LOCATION OF WORK / NUMBER & STREET LOT OWNER BLOCK DESCRIPTION OF WORK: �V C� /At) ££r/ /C4 - 74,4„C SUBDIVISION ADDRESS �— (� /.3 12. / E%tc s Ci�t L.Li .J, Sim 7 NAME OF BUILDER ADDR FB C CAMM ON L., r Uf 1. 40 16 A915 suo iNG Der. CITY C TUKWILA BUILDING BEPIMENT 6230 Southcenter Blvd. Tukwila, Washington 98067 Phone: (206) 242 -2177 Nature of Business: S APPLICATION FOR • APPLICANT BUILDING PERP1IT DATE ISSUED EXPIRAIION DATE PERMIT FEE TOTAL FEE FIRE ZONE oFFICg PHONE PHONE 74 z _ z,t - ✓'� ESTIMATED VALUE COMPLETED WORK 'PLAN CHECK FL d) s LATE PERMIT FEE TYPE OF CONST. 27— l u STATE LICENSE SALES TAX NO. C FIRE SPRINKL S REQUIRED U Yes ONo Name of Ten ant C i / N. s G -ifJJ� ?e)O 0 0 x7.2. OCCUPANCY GROUP USE ZONE Aet, MAX. OCC. LOAD THIS PERMIT DOES NOT AUTHORIZE ANY WORK IN PUBLIC RIGHT•OF•WAY OR ON UTILITY EASEMENTS. SEPARATE. PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, VENTILATING OR Alf? CONDITIONING. HEREBY CERTIFY THAT NO WORK IS TO BE DONE EXCEPT AS DESCRIBED ABOVE AND IN APPROVED PLANS AND SPECIFICATIONS AND THAT ALL WORK IS TO CONFORM TO TUKWILA CODES AND ORDINANCES. 1`! Ca ac T1 TL Iikero/ r trs, ;•‘• "46,1- ; • : .• • ! • '.. • hat POrtton . of the southe0, of the southeast quarter of Section -!•: 2 north, Ranae" W :AA . tiri the City of Tukwila, King County, .-WaShihOtoti..dest(libed as fottAws; • ' • • .." ' - • • 1 losegirining•a,.t 6071er:of the southeast quarter of said Section 2;: Thenc& SO 2022i2O -w al east line of said southeast quarter a distance of 131 the e ,center'ltrie of the F drainage channel, which :58131,71'3 to tei-miritis:at the westerly mat ?in of ChhtiteriSen • Roadk , • • ••,:; : ' W 41,860 -the 'Said P-17 drainage channel :centerline ••• si ;c. • • -: ; • • 'E.00 iOtt t the trlie -point of beginnirrj; tr•NA:f :29'4:59 feet;' • • p ct: ‘thence::;i\181:391.32 t Ott/ti fet to the easterly margin of Andover Park East as recorded under Nci Volume 5035, Pa - , and 66,' Records .or i:1944' 'pei9i'itS;.;; s ;- . 111 - .9V 011).4-7.! •, . . i ,.. i 1 . : e. 4 *6:6i , lz....,:g ' ry j i,r . • -•.;"...44 ; lib ..' . ;'• • t t: ', . ' Tr •• ' "'! a i!" .• s . ..!"..1 , t • ". i :s.... *' ..tv.;: 4 •■• i e i ■ .- :: 1- 5t ,t - 3: ; ,4 ',..T ' '... reVit thergin 297.59 feet; . 0. 7 e et true_ : point of beginning. -.:•••,..••••', • • purposeS 'tattseiiiint for utilities over the north • ' - 910, , :feef? - -friereof r,. tz- . - . • objitet: t04-ar41rIglt!dtrig 1ai ettlfrnexit.', for railroad 27 feet therec,f. I '•••• *. • " - • : • -:•• . —v, .• 15.00 over the east • :.;.; saz '51.1P GL-4, yil GEHEF../ - AHr' - TC711—a^ R0OF LANE L TYP, s • 151 RATTI / FOSSRTTI ASSOCIATES consulting engineers 1.411 fourth avenue building seattle. washinaton 98101 Cn>o c 4i ra PDVF 4 215 >Zoor 1..01xo : IooFik* s.O psF p1.t0o 1,6 2 .4 isT 4x16 �,9 'G-4. 2.5 MIx . 1,1 1• DU= I .,o 2I 5 1211 V I61 LATEr2A L L.D. A - 1 = 52100 -1150 - 29oo 414 -50 8 � -Ca 1. C R 2 �� zbl p F AREA (215tll`� (v20 $14$20 -29'x A 00 0 PROJECT MCC,AKW *t 2 41 CLIENT 6 E N ME-TT DESIGN p C CHECK DATE I v c1 PLAN 50' RUO1• AREA W Ait}OUT WAIL L = 510 3 4 56 rito +"4.040 + 5120 ROOF wr,,= (414s - 1210)s (1$ + 4 5 Gg + 2$2 = 50 .---- JOB NO T v SHEET L- I OF CALcu LATIOO SEISMIC CcacpF. �G r . 0.05h _ 0.05x2.2 . _ (1,10 z 15' 119y7o .0,0741 2 C= o.o6 o.os gas _ o.11a.x 1.33 = 0.15$ '' 0422 WAI.lr WT', N- DIRE~GTIUhI Ilg' 19.3' lu' W= 81.'2. [( 5.+ 2.4. tto ( +(0 + 15x4 t 24.5'i'+551 ,4,,5, 81,2 C 1241+ l3q`31tt 1$2 - 2G4..K E- t0 DIRE -GTION W = 81 18 X C ( 2 . I 461, t i8, i' ) +( x 4 )} Z 1-6)( C 214 .>s4+ t 5' _ 7-30 SCI SM'I� pokcE N -S -- V = ($50+ 2o4-)s 0.158 = (bi �-vtJ -- v= (850 +230)x0,15- l.1lK Ct4EGK Viva 514EA-R. G@ Dtapt +MM lN- l IT= IT— z1 VA. 2 tom_ t 22 010. c -tcK 00E- 42.TUQ.t &)G @ LWE M i ADM pa' LL c Woe t I?a 1144 1 2 OF $ .sA4tc l.D, AN) Lbos M r4ka 1 2oF SE.tS r-“C. L-0 , \/ 47r. a36� (@ L►uE 4 ) 0 uI 2.TutuJtN G- M = 2 x 1812 = 160 )21z515T t+JG M 5-4; :1 '34.lq+20 t 1I 1 RATTI / FOSSATTI PROJECT ASSOCIATES consulting engineers 1411 fourth avenue u building conttlo ,nchlnntnn OA1 =JA L., .. 560 < 48oV, o K 44 R &t /, < 486 lC , 0-- p4 EL LA = 4- i' x t$,'151t 81,2'`= 72,5K PC6 -4,, a vie* ���3x Q,t5 55 4 l9 ROoFPl. `f ( +6 � In- 515TI0G = z63 F ►5: 30 =3 4fc McC44-NIJ 241 CLIENT DESIGN CHECK DATE h = AuLR4&C FkGH = 18. +2.54 160 N pc <r G JOB NO t 4 L -G CONcLu S1oN • HAX RooF pt-4Loos DIAp +RA -t-fl STRESS= 390 < i- d (/11.1100ih4LE 2. GL. Bevis @ RpO F p/4061... LuJ E Act' #5 STRUTS, 6N0 rRA NSF1R. SOA5ti{tC LP TO PANE .S 3'. THE CRITICAL ooEa.TUkNiNG MONSATs OcCOR ® Lt#J M, 8UT TI E F,S,= 3.46. So tT tS ok. 4. 1=R-JM THE CpLCULATWWN A-xjD C Ar- LUSI0/1, 1T SEs 4s - 114E- . 714E GKTIttx ptii✓L5. N /vE A-0E.610A -7E CA-p#cITY TO TRANSFCg- SOAR- - FROM boo F To Fres . Tt43P -E POE TN sNTPRWR STU o si+64134. WA-WS A-R•E tor) 1-DWG Rea) D RATTI / FOSSATTI ASSOCIATES consulting engineers 1411 fourth avenue building svnttlp. wnshtnntnn 9Ain PROJECT M c CA- NN 4t 24-1 CLIENT CNNE.T DESIGN p c L CHECK DATE t �O"� JOB NO.7 SHEET L- 3 OF legal description door schedule alfred h croonquist floor plan