HomeMy WebLinkAboutPermit B96-0154 - NC MACHINERY - STORAGE RACKSCity of Tukwila C.
(206) 431 -3670
Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188
RACK STORAGE PERMIT
Permit No: B96 -0154
Type: B -RACKS
Category:
Address: 17900 WEST VALLEY HY
Location:
Parcel #: 362304 -9011
Zoning: M1
Contractor License No.: NORTHS *15307
Status: ISSUED
Issued: 06/17/1996
Expires: 12/14/1996
Suite:
TENANT NC MACHINERY
17900 WEST VALLEY HY, TUKWILA WA 98188
OWNER LEIGH RABEL & STAR MACHINERY Phone: (206)328 -1600
130 LAKESIDE AVE STE 200, SEATTLE WA 981226538
CONTACT RICHARD CHAFFEE Phone: 206 575 -1671
22257 WEST VALLEY HY, KENT WA
CONTRACTOR NORTHERN STEEL Phone: 206 575 -1671
600 ANDOVER PK E, TUKWILA, WA 98188
*************“**************** Ic************* ** ** * * * * * * * *. * * * * * * * * ** * ** *k **
Permit Description:
INSTALL PALLET RACK IN EXISTING WAREHOUSE.
UBC Edition: 1994
Valuation: 6,500 :00
Total Permit Fee: 210.34
******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
-fl1._(0
Permit .Center Authorized Signature Date
I hereby, certify that I have read and examined this permit and know the
same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate
or cancel the provisions of any other state or local laws regulating
construction }p?r the ,•-r o :nce of work. I am authorized to sign for and
obtain this'buildi,'g. --
Signature:_
Date: if4F 76-
Print Name r, .2__ %/ 2;� -c-.3 - Title c77 -<: ,.,
This permit shall become null and void if the work is not commenced within
180 days from the date of issuance, or if the work is suspended or
abandoned for a period of 180 days from the last inspection.
0 0
Address: 17900 WEST VALLEY HY Permit No: 896-0154
Suite:
Tenant: NC MACHINERY. Status: ISSUED
Type: B-RACKS Applied: 05/31/1996
Parcel #: 362304-9011 Issued: 06/17/1996
*k*A************************4144****41
Permit Conditions:
1. No change s will be made to the plans unless approved by the
Architect or Engineer and_the,Tuwpa,Building Division.
2. All permits, inspectjo107e:Cordsapproved plans shall be
available at the 1Ws-ite to the'St*tt*0 anv con-
struction. The.c;edOCumentse to be maintalned and avai 1-
able until fj,n0: is granted
3. All constr,u,ctibn bc0Ded(ine approved
plans andequy'eMents Of the. Uniform Btiildingtode'11994
4 ValidiWbfRerm4. jhe issuance of a Permit'orapprO of
plan sspCiffc and COMOUtations shall notbe
strueOcbe a permit for, or an 'approval of,HanyViolatiOn
of pnk?ofthe pr,ovisi,P building code or of :any
otheyord the Iurisdiction. No permit'presUMitioA:b
giV0q06r.ity;to violate oi'::Canbelthe provisions
code hai1 be a1id
Edition)-as amended: _
CITY OF TULWILA
A.04, 'ivei,' WKIiiii. ,•�c
� 3
DER4RTMENIN T
3d?4 -"t{t fLi d.
Yf�
qtr .;
�x.��s. :��.,.,
tiri a.
�i .:Fi
PRAL..*
1'+D T-E ,.:g;
* 1 , { .. ; ..,
aAPQR.O:V,EDr
1 +
1 .., ,, i ,4 :: i ,,- ;-sr.,; <c r,.
/r � <.� ~,. ; � 1 • , �f ,.:� ii.S%..Y ; " \Nt !'��' �- '�� 1�: ^ Ac j2 ,d, yF -4.,,,,,, r
z t5 , t , l s r, .,a Yi R iREM'ENT f ry1
��� y:s,.�•,3u,E� , „Gl S; ��COMME ;S'�
.r. J.K�� t t�Yi.. +v {i. .': �4' I�JeY ,4^.tti}��+�1'�{}.�. F:17.1:7; f 'Mfif. :'l:�ii$:'i ��it��i'%.� "'9.•`.f It ��
X Plan Review
Meeting
53 J 110INIT:
BY: x /`13
(init.)
2nd NOTIFICATION
k BUILDING -
. initial review
3RD NOTIFICATION
L� v, ./c 030NSULTANT:
f (ROUTED)
Date Sent - Date Approved
FIRE
-5-.cf�
67 — �, �
FIREPROTECTION: Q Sprinklers Detectors Q WA
FIREDEPT.LETTERDATED: &— (, -5 („.. INSPECTOR: Ji S10
-
INIT: .3 At--t-.S D
O .PLANNING
SNIT:
ZONING: PAR /LANDUSECONDITIONS? °Yes Q No
REFERENCEFILENOS.:
MINIMUMSETBACKS: N- S- E- W-
\JTILITYPERMITSREQUIRED? • Yes • No .
Q PUBLIC
WORKS
PUBLIC WORKSLETTER DATED:
INIT:
BUILDING -
final review
�-J� -�1
'7
TYPEOFCONSTRUCTION:
P,4(---(-)
CERT.OFOCCUPANCY?
°Yes Q No
UBC EDITION (year):
� C c� q
t
INIT: 1/,--, frl
BUILDING
OFFICIAL
//
b j i / (a
(v /3 %
INIT: �.
AMOUNT
OWING:
-0 ^
U
CONTACTED
•
c hay a
DATE NOTIFIED
U) _ ! C(�
�(. ` (
BY: x /`13
(init.)
2nd NOTIFICATION
BY:
(init.)
3RD NOTIFICATION
BY:
(init.)
PLAN CHECK
NUMBER
REVIEW COMPLETED
CITY OF TUKWILA °L
Department of Community Development - Permit Center
6300 Southcenter Boulevard - #100, Tukwila, WA 98188
(206) 431 -3670
DEPARTMENTAL REVIEW
"X" in box indicates which departments need to review the project.
Building Permit Application Tracking
SUITE NO.
PROJECT NAME
kC modem
SITE AD RESS
1 — 7 (O O W es+ VC/ ne3
I/
INSTRUCTIONS TO STAFF
• Contacts with applicants or requests for information should be summarized in writing by staff so
that the status of the project may be ascertained at any time.
• Plan corrections shall be completed and approved prior to sending to the next department.
• Any conditions or requirements for the permit shall be noted in the Sierra system or summarized
concisely in the form of a formal letter or memo, which will be attached to the permit.
• Please fill out your section of the tracking chart completely. Where information requested is not
applicable, so note by using "N/A ", date and initial.
07/15/96
o3UU Jouwcenier Dowevaro, I UKWIIa VV/i y6I00
(206) 431 -3670
DESCRIPTION
AMOUNT RCPT # DATE
Sge"eiAllialin•,•
111011/14:1 � �
BUILDING PERMIT FEE
PLAN CHECK 80 y G
NUMBER - 1 . r lJ �.J
APPLICATION MUST BE
FILLED OUT COMPLETELY
PLAN CHECK FEE
BUILDING SURCHARGEWlidi
MEMO
r, 6 iii• '
OTHER:
1 0. 5
TOTAL •
SITE ADDRESS SUITE #
�� 0 (. gzc"--- � �z,<.) i �
VALUE OF CONSTRUCTION - $ 6 . � y;w c o
C�IJ
P �
Rd ECT NAME/T ANT (
ter. r � _
ASSESSOR _ ACCOUNT #
6622 9J/1
TYPE OF • w : uilding • Additio r • Tenant Improvement (commercial) U Demolition (building)
WORK: ack Storage 0 Reroof 0 Remodel (residential) 0 Other
DESCRIB DRK TO BE DON •
BUILDING USE (office, warehouse etc.)
66)69 e6_,-/-0e,6 - & - - ---
NATURE OF BUSINESS: J�, --- f p .2 •7 6 A-)
p �0 ! If
WILL THERE BE A CHANGE SE 0 Yes Yes, new building requirements may need to be met. Please explain:
1
^ '.' 1 '
SQUARE FOOTAGE - Buildi • : " : • . • • - _ Jr 4Lea.oLC nnetn ct ic±n P
. _
/
r I THERE BE STORAGE OR E OF FCA • Bt COMBUSTIBL R HAZARDOUS MATERIALS IN THE Egue I G.
_ No 0 Yes IF YES, EXPLAIN:
I RE PROTECTION FEATURES: Ai S•rinklers 0 Automatic Fire Alarm S stem
PROPERTY OWNER
PHONE
ADDRESS /jFer, 44 - , . r 2....0 � ,ff�i ?ri .Z i -,
1 �
CONTRACTOR , , _ ,
A do. " � . ./
ONE c -_ -,
> - i r 7^
ADDRESS �,r,25 2 etA�.S 1�"Qe 1 , ' �f
fwd
IP Y70,E-2--
WA. ST. CONTRACTOR'S LICENSE #
EXP. DATE
ARCHITECT ,-------
PHONE
ADDRESS ----'"�
ZIP
CITY OF TUKWILA
Department of Community Development - Building Division
BUILDING PERMIT
APPLICATION
I HEREBY. CERTIFY I: IfiAVE READ AND ,EXAMINED THIS APPLICATION AND KNOW THE SAME T
BE TRUE AND CORRECT, 'AN' M AUTHORIZED TC('APPLY> FOR THIS PERMIT.
BUILDING OWNER SIGNATI . p c
OR PRINT NAME �/
AUTHORIZED lC 14
AGENT ADDRESS 7
DATE
— s i c = ? e t /77%
PHONE
lF�tZIP . 7 =:
kri4 `r ti
PHONE 5 ;.;:_' 7, c1:' �G
CONTACT PERSON
APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please . e sure to fill out the
application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at
the Building counter which provide more detailed information on application and plan submittal requirements.
Application and plans must be complete in order to be accepted for plan review.
VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of
Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting
application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is
subject to possible revision by the Building Division to comply with current fee schedules.
BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor
licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this
permit application and obtain the permit will be required as part of this submittal.
EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall
expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180
days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition).
No application shall be extended more than once.
If you have any questions abor3ro&'process or plan submittal requirements, please
contact the Department of trenitiuJf/!$Wb velopment Building Division at 431 -3670.
DATE APPLICATION ACCEPTED
3 - (
I I 4
PERMIT CENTFf,
DATE APPLICATION EXPIRES
t N22JD3
COMMERCIAL
NEW COMMERCIAL BUILDINGS /ADDITIONS
Q Completed building permit application (one for each structure)
Ej Assessor Account Number
Twb sets (2) of the following:
LI Specifications
EJ Structural calculations stamped by a Washington State licensed
engineer
ra by o Washington State licensed an
Topo surYey
n Energy calculations stamped by a Washington State hcens
engineer or architect
Legal description
I I Wonting drawings, stamped by a Washington State Iicen
architect, which include
• Site plan
Architectural drawings:::
• Structural drawings
• Mechanical drawings
•
Elevations
Civil drawings ::<
• Landscape plan
Completed utility permit application (one for entire project
Six (6) sets of civil drawings
.
NOTE See utility pennlrapphcabon and checklist fir apecllk utbll
submittal. requirements
RACK STORAGE
Completed building permit application
Assessor Account Number.
wo (2) sets •of plans; which include:
Building floor plan showing
• Entire: space :where, packs will be loca
• Exit doors
Dimensions of all aisles
• Tenant space floor plan showing rack storage layou
• exits
NOTE .Include. dimensions of racks (height, width and length),'
and exit ways ,on plan
StrUcturaf calculations stamped by a Washington State,license
engineer (rack storage 8'. and over)
RESIDENTIAL
NEW SINGLE•FAMILY DWELLINGS /ADDITIONS
LI Completed building permit application (one for each structure)
n Legal description.
n Assessor Account Number
n Two sets (2) of working drawings which include;
Site plan ---► (On plan, show closest hydrant location.
Foundation plan Include access to building, stowing
• Floor plan width and length of access.)
• Roof plan
• Building elevations (all views
• Building cross-section
• Structural framing plans
Washington State Energy Code data
n Completed utility permit application
Six (6) sets of site plans showing utilities
SUBMITTAL CHECKLIb T
NOTE; Building site plan and utility site plan maybe combined See
utility permit application and checklist for specific submittal requirements.
Additional topographical and soils information may be required tf unique
site conditions.
•
COMMERCIAL TENANT IMPROVEMENTS
Completed building permit application (one for each stru cture or
tenant )
Two: (2) sets pf censtniction plans, which include
• Site pfan ; 3 • )
• Location of Tenant specs
• Existirtg and parking
• Landscape .
plan (11 applicable, i,e , cha
OveraII bulkimg pier
• location
• Use of adjeopnt (common wall) tenant .
OveraN dimensions of building or square foots
Floor plan of proposed tenant apace
• Tenant space ,plan with use of each room labelled ;`
Exit egress patterns
• . Now walls; existing wall, and walls to be demolished
Construction details •
• Cross sections showing wall' construction and method Of
attachment for floor andceifng
Structural calculations stamped by 'it Washington 'State licensed
engineer may be required if structural work be done •(2 sets)
NOTE : :ll any utrlrty work /s to be clone, submit separate utility permit
•
applicatron and plans.
REROOF
Completed building permit application (one for each structure
Assessor :Account Number:`
Narrative describing existing roof, material being removed, and
material being installed
NOTE :. A certification letter is required prior to final Inspection and sign :
1'
ANTENNA/SATELUTE DISHES
r--, Completed building permit application
Assessor Account Number
Two (2) sets of plans, which include;
Site Plan (showing building and location of antenna/satellite dish)
Details antenne/satellite dish and metho of attachment
• Structural calctilatiOnf stamped by a Washington State license
engineer may be required •
RESIDENTIAL REMODELS
Completed buildng permit application (one for each structure
Assessor Account Number.
Two (2) sets of working• drawings which inclu
• Site plan
Foundation plan
• •: Floor plan
• : Roof plan
• Building " elevations (all views
Building" cross= section
Structural framing plans
NOTE: if any uti work is to be done provide utility permit application
and plans must be submitted
REROOFS
Completed building permit application (one for each structure
ri Assessor Account Number
Narrative describing existing roof; material being removed, an
material being installed
NOTE A ;cord-Cation letter la required prior to final Inspection and signs ::
off of the permit
A*- 4k•4:4.4•k•.4kk*.4.*•A*
CITY OF TUK.WI:LA. WA
hAk * *:44t*lock4.***k:1
TRANSMIT Plumber:
Payment Method:
Permit No:
Parcel Nu:
Site Addre=ss:
This Payment
k **i *hA. *-1 *k *•A?• *A0
Account; Coda
000/322.100
000/34!!!.030 •
000/306.904
•
G
.4 .4 t * *A kk *.' < *• t.* 4- *.hk•4/• *'r **•kh.k +1••l.*A * *. *****:4*A *•.
11.Ffr!:1t:3.
L4 f r:k+4A k 4 h•k. 1 r*•: 4 *k*4 ** **k**.** *.4 *. irt \k- *•4
9600412 Cimcur.t: 210.34 Ot /31 /96 14:2'
CHECK Notation: NOUTHf::itW STEEL :trait: RJP
B9G--0154 type: I3•- RACKS RACK STORAGE PERT ^:I f
362304-9011
11300 WEST VALLEY HY
fotal Fcaea. 210.34
210.34 Total ALL Pmts: 210.34
Balance: .00
.4 * AAA* **A.4itI * **k4,4a *A * .4 — *ix *AAAk4•A *A *
L e=,cr i rat i on (amount
BUILDING - NOi4PES 1.24./5
PLAN CHECK - NON1 E'; (31..09
STATE I31J] L.DING SURCHARGE 4.50
0084 06/03 9616 TOTAL 210.34
,
- • ' '
City of Tukwila
Project Name 1 12 ?-4; 4 /07
Address /790O 0) kl,/
)1( Retain current inspection schedule
Needs shift inspection
Sprinklers:
Fire Alarm:
Hood & Duct:
Halon:
Monitor:
Pre-Fire:
Permits:
Authorized Signature
TUKWILA FIRE DEPARTMENT
FINAL APPROVAL FORM
Approved without correction notice
Approved with correction notice issued
•
John W. Rants, Mayor
Fire Department Thomas P. Keefe, Fire Chief
•
Permit No.
FINALAPP.FRM T.F.D. Form F.P. 85
Suite #
Date /0//29‘
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-44.39
Project:
t� r �. , �lA-GN I N'F1V)
Type of inspect' n: ,--
"l /-I A
Address:
/7/ V1/4 li3O1 -
Date called:
7 - is
Special instructions:
Date wanted:
a.m.
Requester: � USTr
Phone No.:
xes;crstm�ex ^.`S�'k`Y J'a`sv '
1 --------4
-+, INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 9818
Approved per applicable codes.
COMMENTS:
I
r
4v... .._<...�,.iu..n��Y.,, -._. rt. iL: �J�r :� .�.i�+s�iva��a:�i�;af:ir. at�.7n:;h'-. .
PERMIT NO.
Corrections required prior to approval.
Inspector:
Date:
7 / /al'c9
$42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection.
Receipt No.:
Date;
RZ, MALI4 iM e-12-1
Typv Fi 1\1 AL ,
n e w% 9r 04.41 1 41
Date called:
Special instructions:
(-
61-la A4
•
Date wanted 9
p.m.
Requester: sr( MARIN
Phone No.: Z 1 — 6goo
stWASOnectsricactt
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
INSPECTION RECORD
Retain a copy with permit
(206) 431-3670
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:.
1
1 e /496. /LA CtL I ki STA-LLATioi (S
Inspector:6S
Date:
1 1 if j?6
$42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must
be paid at 6300:Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
COMMENTS:
kit(
Typ� of 'n section: F ' m
Date called: Lo z 9.
Special instructions:
� -O r�
F— v'�I�)
Date wanted: _ _ i a.m.
m
p p..
Req ter•
t N AAA R 1
Phone N
z-
POSE Z/6N
r 0►CAT I
4UYIC) I. n
frit_ VeL . _
.c, 6,) CIJ rt.C.
BSc AT
1 -T SO Sa.. +14
. ItJ A
A.
• 'ect: ,
• .. m vti6g , `AL `r
i
kit(
Typ� of 'n section: F ' m
Date called: Lo z 9.
Special instructions:
� -O r�
F— v'�I�)
Date wanted: _ _ i a.m.
m
p p..
Req ter•
t N AAA R 1
Phone N
I
INSPECTION RECORD
r
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
•
: Saari !;:r.3a't:.Y'L'.x,aarsrew'^.
MIT NO.
(206) 431 -3670
Approved per applicable codes. EXLCorrections required prior to approval.
Inspector:
Date: C9(2,
° /q�
$42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
CITY OF TUKWILA
x ab x i‘
x l x /6
s x a V x lb
x
x
x
GRAND TOTAL
RACK STORAGE DIMENSIONS
LINEAR FEET X HEIGHT = TOTAL
=
MEM
RECEIVED
CITY OF TUKWILA
MAY 3 1 1996
PERMIT CENTER
1.0
.(
/11,7:
!ope /f/e-7
RECEIVED
CITY OF TUKWILA
MAN 3 1 1996
PERMIT CENTER
r
VI VIN
F.
IAA UM MA
IAA __
H 111
000
V1 0 0
-N
N
aav
(44
C4
72k1-1 5 2 •
CITY E1110
A
5 1996
��wlr u
BUI i ING DIVISION
I 33 if
Si' --Ec.. Pau er 2,rr1&5 rya. NI, e, morc -,14 ER.ki ru KUL LA
USIA C, TNg 1994- US C. G I44-' 22
vvvsoi-ks 4 9 1=02 , A sls
r (c1RFI) w Ezb.30 C e3)
) C
TrzA -,4sU D1,2 62�aCt-n F(// ► iiss)
L.orlc,ir
200 / Lerd 61 — 1=.4L 24 G.1 DCo U .
6A4Z: 1 V 13 ..1•0 y. C ...1( () L 1,133
, 1 3 3 14
+0 , 4 AlrAV r -Lese, (L
Se►,s }t/t = 24.3. 31
)
. see, - 3 = 33
el.s 2 - �• 3� k
lad R (p 3o ic
.2• y2 X 5►1L: P-:LT'r Kg-j S
TA 2k 9.fl `61 5 •a 1. 53
V A r- 2 X 1,84 x 0, %15 y 3,22 k
1- /TA ¢ vlvA
M. M is-1-$7- 4. )
3
vu t. p
T l
44- e V _ 1.
KArCe L s 2,
f3 (tM-k P = 2.76
C EXPIRES 7/14/ VC
1
v, p,$7 l 645t-.
P d. 4 13 , 40.1, ``
(1/12" eke,) r� A-sa-
- LC ap 0,2.7 tamkoir Spec /A-c.
( )40' IrCTco -1 ,
9. ok 4 I. •D
PERMIT CENTER
RECEIVED
CITY OF TUKWILA
MAY 3 1 1996
Porc s d- Gv /k St g ti'rs t .4015 e ; 4. $ 41
A - 1 . Z$ 39 144444 r* 0.4 43 4
yn k$C )6 4 4 = ° C :. 97, 63
fy ¢2,05 kc4' Fa 14. -o Ls..'
V I N V I
z ==
In In
v1or
�aa
^ a
NNN
1 74 7
3 741 S-C s
Cre s/96
D, 2a 3' x J44- . 413 s. 5,4-s- o'k
6,0, 44/0 /3,67 !c
Pow-8 p/.4f 9 "x L 0" le 3 /g k gerroK,
N
I,J LT 4 < 7 r 3 l y
ff ArT TbP
c.1.1-6-e44 O99 Cie pLATE-5 vs. N 4 A-+J Ef+&c .
p = 2 ( .0 u.'' -7 -F = o, CZ 6 L
1u D. 526 ( /•1s) z CADS k `/"
f F x 4/3 - 3 4, ,o ks2
,eaRo = 0, 364 " e k C 4e- i )k-c = 3/8
C1EGK r tsraM yJ.L AL, kJ= 0, a1r(2 ,0 - 0.81)//4-
711" Tl scod Sit = 0. Z4. 6 k ` G " oi< 4 (-our
P 'ro-^ p1M
3 lo : At = gS. e w
d, 144 ILS.► D'k < AAA-2)W rr , 3 .Pc K 413 = o , 2 c7
WI n 0. 144 ( 3.o) /a - 0.64? 144
R QRo t = o . ;2g `' o k < ,q.rroa -c. -
31
8
>> P
9631
o �
4 /2
7/
= S 4 I r ' I.... / 4 '
yd -
O. br)
I gksE g I, /z L a y Core CIA : 0.10¢ P. 5'24
0. 524 - p6a)2-4
2.0 ko Q2. s. q
rgb y (2,B•0+ r.r f 9, <)(Z -8.6 ,s+ 10)/144
7.5‘13 Fr'"
51. 7.3/3. /4. Cc afr. ,N +x
k'/
VI 1/1
W W W
000 o
•- eY a
aaa
rrr
C4 N N
Mo R-r # i'f S"rt -
LONG RrUD
P.542
p.40
CIL(4
Dta ; PR et LA- A 4 `c HID r at 2 84-4(
(
1%RkkK A/2E 144os G,CZric, .
ISM V = 6.3 x l.,o k(2,75/8) k 3 „ 4.2.0
D.1o8 k F 0,247 k r p . 32s'
14M
G ) 6:50ev1
V t
. 1b,4o
(.1)
4 a
/3Tie 5/96 I
L
Go -S
Z7.7 it
�}R.►� M-o t cm-
1 ?'*A"4 ;& 1.5c- S-o t ;c 4.4.W1 ti' Sx 1,'(a5 ""
4-- P444 t3RkC Z 561.5 PlA 20, SS " (m � ')
Sm "A " Ls 61-0 Ste, IP14 } b ! (3 k u 4 . Co nt oCis
aN , • 1 64A Pik L c y r- t 6t/2k» T1./ Lees
IL/ 14 - V z 4- .07 ( 4.2/) < 144 /b' = 1) . 22 k
g k < �1 ,
4 lvl * 3 4.78 k �bx z 19,10
1 s , 1 �o k
% S (4 20 /2..) 1444.) 0 .q 2 -
304 x 2.-%5b'o r 444-
LJiga
9431
et 7
sS
,3
\I— 5r ..
is s / 96,
Cot, tbio.n
,1,4rE72co 4 ( C. 1) 0444 r A (_44
Arlo Ar 2A- OS T L'2a l CA-L
. 3
,105 l.O Ai DD$S4 4- 5,. a •qfS «.`
P$ rv.$0 -'7 A = 7 . 33 M.
M = 1 $ t `' ' 'COsid s 1 9. 54 ks-4
Ft, ,, . ( s 3o k.s:.
5" k z k, i► A z 3" LT 2- 41 4
(Y -lr)x 7, 5/, CDAre 5
06L1r) ( . 3131 (re x : 88 , 8 3 kh:
r, ti
1151 2.0.2 s , 0 1 1 4 Cw s 3 , 20 3 frt.
�.� - 44.27 k -1
re 3).00 Fy /Z = 2S
r ry 2934-
F4 rA/ ,q2 .z i 5, 54 k...'
1, 33
943/
4= 1-1 3 00
4—
MODEL
T c
B
In
X
in
X C
X C
V� ---
1. _x
rc
Sy
Ina
rr
In
AREA
In
LM 15 .075
3
1.625
.689
.582
.388
1.156
.205
.219
.686
.411
LM20 .075
3
3
1.435
1.023
.682
1,263
.872
.557
1.165
.618
LM30 .105
3
3
1.45
1.373
.915
1.249
1.164
.752
1 .15
.859
LM20/ 15 '0 075
3
4.625
2.607
1.78
1.187
1.231
2.577
.988
1.481
1.143
LM20/20' 5
3
6
2.714
2.222
1.481
1.268
4.701
1.431
1.845
1.349
,
LM30/15' 0
3
4.625
2.789
2.126
1.417
1.23
3.0521.094
1.473
1.384
LM
3
6
2.951
2.568
1.712
1.262
5.45
1.788
1.838
1.590
LM30/30
3
6
2.707
2.98
1.9861.256
6.387
1.94
1.839
1.875
r
.23
.67
-- f--X
....I .87 `F
COLLUN SECTION
PROPERTIES
.53
Lt
LM
X
'INGEY
DATE
BAPR.'91
ND.
LM /
.110 MEN
R -2
REVISION
DATE
BY
X
GAGE
T
in
X
in
I
in
S
in
r
in
I y
in
Sy
in
r
in
AREA
in
16
.060
.4189
.0893
.1190
.6234
.0379
.0456
.4055
.2297
14
.075
.4261
.1081
.1440
.6169
.0464
.0564
.4043
.2839
12
.105
.4405
.1418
.1890
.6041
. 0621
. 0767
.3999
.3885
10
.125
.4551
.1706
.2275
.5914
. 0764
. 0960
.3956
.4878
10
9
z 8
d
O0 7
-J
<0 6
x
d N 5
u.10
d 4
o0 3
JF-
Z 2
1
BRACING SECTION
PROPERTIES
0
20 30 40 50 60
LENGTH IN INCHES
B= 1 1/4
PREPARED HY
P. TINGEY
DATE
10MAY91
NO.
:1 1111111M111111111111111111111111111111111
111110■1111111111111111111111111111 111111111111=1111111111111111111
111111111M111111111111111111111111111111111111111111 111111111111111111111111
111111111111111112.111111111111111111111 rMU111111111111111111111W
.�..1111111:1111111►!1 1 n (, 11111111111111111111111111111111111111111111111
emtmmo•maowiom • mom
- aIM1 ,' �� - Ell __ 111111��
4 Ga M.r��N UM,
ENE 1111111111111111111M11111111■1101 11 NM=
11111111111111111M11,111. 11111111111111
11111111111111111 M1111
70
DRAWING NO.
80
R -3
REVISION
DATE
13.3
14.6
10.6
9.31
7.98
6.65
5.32
3.99
2.66
1.33
0
J [J
IF
BEAM SECTION
PROPERTIES
PREPARED BY
P.S. Ting ey
DRAWING NO.
R-1
DATE
14 SEP.'93
REVISION
NO.
DATE
BY
MODEL
- C 1
_ ,C
p C
I x
in 4
SX
in 3
rx
in
Iy
in 4
S y
in
r
in
AREA
in 2
LB020
.075
2
.75
.2928
.274
.716
.6033
.4133
1.031
.5718
LB030
.075
3
.75
.7604
.4659
1.026
.8786
.6054
1.103
.7218
L8035
.075
3.5
.75
1.1854
.6313
1.223
.9475
.6712
1.093
.7922
LBC30
.075
3
.75
1.3689
.8817
.184
.9403
.6099
.9820
.975
LBC35
.075
3.5
.75
1.951
1.0473
1.363
.9705
.6159
.9614
1.050
LBC40
.075
4
1.5
2.6631
1.2769
1.538
1.105
.7096
.9921
1.125
L8C45
.075
4.5
1.5
3.5073
1.5033
1.709
1.2449
.8025
1.018
1.200
LBC50
.075
5
1.5
4.64-37
1.7655
1.908
1.3902
.9029
1.044
1.275
LBC55
.075
5.5
1.5
5.7951
2.0453
2.071
1.5269
.9975
1.238
1.350
LBC55A
.105
5.5
1.5
7.7919
2.7571
2.038
2.0719
1.3498
1.051
1.876
LBC60A
.105
6
1.5
9.587
3.1421
2.192
2.1979
1.4517
1.049
1.995
LBF356
.060
3.5
1.5
1.2039
.6277
1.274
.7576
.5097
1.011
.7414
LBF354
.075
3.5
1.5
1.4739
.7699
1.267
.9284
.6242
1.006
.9181
LBF404
.075
4
1.5
2.0512
.9481
1.437
1.0635
.7190
1.035
.9931
LBF454
.075
4.5
1.5
2.7526
1.141
1.605
1.1984
.8143
1.059
1.0681
LBF453
.090
4.5
1.5
3.2119
1.333
1.598
1.3985
.9497
1.054
1.2578
f
--- 2 3/4-
-4. 7/8
1 7/8 --
t
D
CoLu 64144 s ,1 5 GR
F.4.. k
P IV114reiti ) 5 C ( 01.0 44
1 'DtAwt-I141. 11 / ss
464% 4- .
t?O61 L.
VOL `a1-1 Pfr F1 7fr 11.40 kc-:
11 C• UM Meat US:e F 1.0 a-
Jig446 c I rvi 0115 og, LAI 2. o
z o7s"
- . P;*% Obi) x707,5 x65
‘c(1 /24 W 3 Co Li 6t
Pe T:
• i
.
,•••
rwgs
61 12- 94-
1,45 (-TS
to),:ir—Fottez--
e64-rg4)
U& Po /43 k Fo A-t;4- . czt-a;rws .
P S P - .:f7
1.6 6.7E 4 0 . 56 1K 2,7S 4- 0.07 z 17.1S
56S H4 1,4 x /3 2 23.13 kJ
reg. FT 40 —•7 4S 3 •
1,71+4
Lri Awo L1 Vo s Ite.# r. 0 (Ss = 1.4
•Is KiL 7 .2.D. 43'S k
( ( pi 2 ( C 5,s" z /. /1 k
145e P,,
Aldo 561s 23.'3
3 14.
WAS
Fire Department Review
Control #B96 -0154
(510)
Dear Sir:
City of Tukwila
Fire Department Thomas P. Keefe, Fire Chief
June 6, 1996
Re: N.C. Machinery - 17900 West Valley Highway
The attached set of building plans have been reviewed by
The Fire Prevention Bureau and are acceptable with the
following concerns:
1. In double row racks with heights of storage up to and
including 25', an average nominal 6" transverse flue space
between loads or at rack uprights shall be maintained.
(NFPA 231C 4 -3.1)
Maintain minimum 6" longitudinal flue space between
back to back racks. (NFPA 231C)
2. High -piled combustible storage is combustible
materials in closely packed piles more than 12 feet in
height or combustible materials on pallets or in racks more
than 12 feet in height. For certain special- hazard
commodities such as rubber tires, plastics, some flammable
liquids, idle pallets, etc., the critical pile height may
be as low as 6 feet. (UFC article 2, sec. 209 -H)
To use any building or portion thereof exceeding 500
square feet for the storage of high -piled combustible
stock. A floor plan showing the dimensions and
location of the stockpiles and aisles shall be
submitted with applications for such permits. (UFC
8101)
3. Where storage height exceeds 15 feet and ceiling
sprinklers only are installed, fire protection by one of
the following methods is required for steel building
columns located within racks: (a) one -hour fire proofing,
(b) sidewall sprinkler at the 15 foot elevation of the
John W Rants, Mayor
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 57.5-4439
Page number 2
City of Tukwila John W. Rants, Mayor
Fire Department Thomas P. Keefe, Fire Chief
column, (c) ceiling sprinkler density minimums as
determined by the Tukwila Fire Prevention Bureau. (NFPA
231C, 3 -2.3)
4. Storage may not be closer than 36 inches in all
directions to ceiling -hung "Space or Unit" heaters. (UFC
1109.2)
Storage of combustible materials in buildings shall be
orderly and maintained not less than two feet from the
ceiling and not less than 18 inches below sprinkler
head deflectors. (UFC 1103.3.2.2)
5. The total number of fire extinguishers required for
your establishment is calculated at one extinguisher for
each 3000 sq. ft. of area. The extinguishers) should he
of the "A11 Purpose" (2A, 1OB:C) dry chemical type. Travel
distance to any fire extinguisher must be 75' or less.
(NFPA 10, 3 -1.1)
Maintain fire extinguisher coverage throughout.
6. Sprinkler protection shall he extended to all areas
where required, including all enclosed areas, below
obstructions and under overhangs greater than four feet
wide. (NFPA 13 -4- 4.1.3.2.1)
All new sprinkler systems and all modifications to
existing sprinkler systems shall have fire department
review and approval of drawings prior to installation
or modification. New sprinkler systems and all
modifications to sprinkler systems involving more than
50 heads shall have the written approval of the
W.S.R.B., Factory Mutual, Industrial Risk Insurers,
Kemper or any other representative designated and /or
recognized by The City of Tukwila, prior to submittal
to the Tukwila Fire Prevention Bureau. No sprinkler
work shall commence without approved drawings. (City
Ordinance #1742)
7. No point in a sprinklered building may be more than
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439
Page number 3
City of Tukwila
Fire Department Thomas P. Keefe, Fire Chief
200 feet from an exit, measured along the path of travel.
(UBC 1003.4)
Exit doors shall be openable from the inside without
the use of a key or any special knowledge or effort.
Exit doors shall not be locked, chained, bolted,
barred, latched or otherwise rendered unusable. All
locking devices shall be of an approved type. (UFC
1207.3)
Dead bolts are not allowed on auxiliary exit doors
unless the dead bolt is automatically retracted when
the door handle is engaged from inside the tenant
space.
8. Obstructions, including storage, shall not be placed
in the required width of an exit, except projections as
permitted by the Building Code. Exits shall not be
obstructed in any manner and shall remain free of any
material or matter where its presence would obstruct or
render the exit hazardous. (UFC 1203)
Aisles leading to required exits shall be provided
from all portions of buildings. Aisles located within
an accessible route of travel shall also comply with
the Building Code requirements for accessibility.
(UFC 1204.1)
This review limited to speculative tenant space only -
special fire permits may be necessary depending on detailed
description of intended use.
Any overlooked hazardous condition and /or violation of the
adopted Fire or Building Codes does not imply approval of
such condition or violation.
John W. Rants, Mayor
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 575 - 4439
Page number 4
Yours truly,
City of Tukwila
Fire Department
The Tukwila Fire Prevention Bureau
cc: TFD file
ncd
John W. Rants, Mayor
Thomas P. Keefe, Fire Chief
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone (206) 575 -4404 • Fax (206) 575.4439
/ / % / / /l % / / / /lJ / / / / //% ✓ l%/ l// r//(/✓ /( /J_J ✓/' ✓j✓ % %lJ( / / / / / /I✓f' / / %I l /f / / %N /% l /J / % /l✓f ✓ //Jl! /✓ ✓ / /( /J/
✓i /iN✓iii� ✓{ iii ✓i /iiiiii J! / ✓iJ: ✓i / / / ✓,
1
4 El T� W
DEPARTMENT OF LABOR AND INDUSTRIES
TNiS_ CERTIFIES THAT THE PERSON NAMED HEREON IS REGISTERED AS PROVIDED BY LAW AS A
EN
: iL ly Yi HU
032
STATE OF WASHINGTON
F825. 052 - 000(3.82)
__ /vj //mss �If/1M/�(Y % M/ I.Yyf.W(_V�fJ(Y{/JiWNIN/lNVrlr: ✓(fNN /Nf/1 IINN /I ��A!! %h %/V %( ✓ % %f % %� %I /%j {: %( / %l %j /J � % % / /J /J /l /r / %l / %/X
YU 1g
irgi .1
sr 0,,SIA N8:i.'aS311 ,
g C.'FtVEI DATA
O ,?:2/ 6
0l!'t'aY95
/ / % / / /l % / / / /lJ / / / / //% ✓ l%/ l// r//(/✓ /( /J_J ✓/' ✓j✓ % %lJ( / / / / / /I✓f' / / %I l /f / / %N /% l /J / % /l✓f ✓ //Jl! /✓ ✓ / /( /J/
✓i /iN✓iii� ✓{ iii ✓i /iiiiii J! / ✓iJ: ✓i / / / ✓,
1
4 El T� W
DEPARTMENT OF LABOR AND INDUSTRIES
TNiS_ CERTIFIES THAT THE PERSON NAMED HEREON IS REGISTERED AS PROVIDED BY LAW AS A
EN
: iL ly Yi HU
032
STATE OF WASHINGTON
F825. 052 - 000(3.82)
__ /vj //mss �If/1M/�(Y % M/ I.Yyf.W(_V�fJ(Y{/JiWNIN/lNVrlr: ✓(fNN /Nf/1 IINN /I ��A!! %h %/V %( ✓ % %f % %� %I /%j {: %( / %l %j /J � % % / /J /J /l /r / %l / %/X
1
DYNO BUILDING
SCALE
59(9-015i
:
(TYP)
_ UPRIGHT e�
15 ,«
(TYP)
)
mod«
LEAN-TO BUILDING
SCALE. 1 «e«
(TYP)
UPRIGHT . 7 - LM30 FRAMES
1 17
NOTES:
» _« FRAMES ARE _, EXCEPT a _r__:
,__
+
crrPOTaWILA
MAY /a
PERMIT CENTER
1/8
2" TYP
AS NOTED — ' r
19/32 "0
12' -0"
SIDE FRONT
TYPICAL RACK ELEVATION
SCLAE: 1 /4" =1' -0"
.375 R
Al LM 30: UPRIGHT COLUMNS
2 HOLES --
3/16 j/
I /16[/ 7— K ra '
CNI
.075" THICK
1/2"
8 STRUT
.105" THICK
7/8" 5 1/4"
A 7„ 4
BASE: 3/8" THK A36 MILD STEEL
Dl
I9L9 -0154
.375R
OO(0)�OCO
C? C) C)1 1 :0
❑ ❑
AS NOTED
2" TYP
/8'
1 J
.531 SQUARE - 3/4"
LM 20: UPRIGHT COLUMNS
9 I/2"
075" THICK
BACKING PLATE: 3/8" THK A36 MILD STEEL
BRACKET ASSY
AS NOTED
F Y 181``
BEAM SECTION .075 THK.
ASTM A570 GR50
0
LBC 50 LOAD BEAMS
(p)FLOOR ANCHOR DETAIL
SEE NOTES FOR SPECS.
NOTES:
1. PALLET RACKS ARE MFD BY LODI METAL TECH, INC.,
OF LODI, CALIFORNIA.
2. STEEL USED IN ALL RACK ELEMENTS CONFORMS TO
ASTM A570 GR 50 WITH Fy =50 KSI, AND Fu =65 651,
3. STEEL USED IN ALL BASE PLATES CONFORMS TO ASTM
A36 WITH Fy =36 KSI, AND Fu =58 KSI.
4. MAXIMUM RACK LOADS SHALL BE 4000Ibs PER LEVEL
PER PAIR OF BEAMS.
5. CONCRETE SLAB IS GIVEN AS 5 1/2" THICK, WITH fc'= 2000psi
6. ALLOWABLE SOIL BEARING IS 1500 PSF FOR GRAVITY
LOADS, AND 2000 PSF FOR SEISMIC OR SEISMIC +
GRAVITY LOADS.
7. ALL RACK UPRIGHTS ARE AS FOLLOWS.
A) LM30- 192 -36
B) L820- 192 -36
8. ALL RACK BEAMS ARE LBC50 -144
9. BEAM -TO- COLUMN CONNECTIONS UTILIZE 4 -PIN BRACKETS
AND "A' TYPE WELDS.
10. TIE -DOWN ANCHORS SHALL BE HILTI KWIK - BOLTS,
USE 1/2 "0x5 1/2" BOLTS, ® 3 1/2" MIN. EMBEDMENT,
TWO PER BASE PLATE. SPECIAL INSPECTION IS NOT
REQUIRED.
FaPINES7p4f96
CRY ECE TU EO MMU
MAY 3 1 1996
PESMIT COWER
N •