HomeMy WebLinkAboutPermit D03-205 - GENE JUAREZ CORPORATION - TENANT IMPROVEMENTGENEJUAREZ
CORPORATION ��
JU
UO
N
W =.
10828 EAST ALL.
u
MARGINAL WAY S
u_<
N.
Z �.
O
Z �.
U �
O N;
o �.
D03 -205
W :
Z W
= 0
Z
W
F- I
O F-'
L
Cit y of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
DEVELOPMENT PERMIT
Parcel No.: 0323049164 Permit Number: D03 -205
Address: 10828 EAST MARGINAL WY S TUKW Issue Date: 08/05/2003
Suite No: Permit Expires On: 10/22/2004
Tenant:
Name: GENE JUAREZ CORPORATION
Address: 10828 EAST MARGINAL WY S, TUKWILA, WA
Owner:
Name: E MARGINAL WAY PROPS LLC
Address: 3006 NORTHUP WAY STE 101, BELLEVUE WA
Contact Person:
Name: DAVID KEHLE
Address: 12720 GATEWAY DR, SUITE 116, TUKWILA, WA
Contractor:
Name: M M I SERVICES INC
Address: 245 S SUNSET WAY, ISSAQUAH WA
Contractor License No: MMISEI *094P5
DESCRIPTION OF WORK:
REMOVE NON - BEARING, NON -RATED DEMISING WALL, AND REMOVE NON - BEARING STORAGE ROOM; INSTALL NEW
NON- BEARING OFFICE WALLS; ENCLOSE EXISTING 900 SF CABINET SHOP TO ROOF DECK
Value of Construction: $23,000.00 Fees Collected: $603.86
Type of Fire Protection: SPRINKLERS Uniform Building Code Edition: 1997
Type of Construction: VN Occupancy per UBC: 0016
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone: N
Hauling: N Start Time: End Time:
Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation: N
Moving Oversize Load: N Start Time: End Time:
Sanitary Side Sewer: N
Sewer Main Extension: N Private: N Public: N
Storm Drainage: N
Street Use: N Profit: N Non - Profit: N
Water Main Extension: N Private: N Public: N
N
Water Meter:
doe: Devperm
** Continued Next Page **
D03 -205
Phone:
Phone: 206 433 -8997
Phone: 425 369 -8655
Expiration Date:03 /04/2006
Printed: 06 -14 -2004
ia:n
Print Name:
doc: Devperm
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Permit Center Authorized Signature:
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws
regulating construction or the performance of work. I am authorized to sign and obtain this development permit.
Signature: ��/ Date: - I e
Date: // - Dy
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is
suspended or abandoned for a period of 180 days from the last inspection.
D03 -205
Printed: 06 -14 -2004
Tenant:
Name:
Address:
Owner:
Name:
Address:
Contact Person:
Name:
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Parcel No.: 0323049164
Address: 10828 EAST MARGINAL WY S TUKW
Suite No:
GENE JUAREZ CORPORATION
10828 EAST MARGINAL WY S, TUKWILA, WA
E MARGINAL WAY PROPS LLC
3006 NORTHUP WAY STE 101, BELLEVUE WA
DAVID KEHLE
Address: 12720 GATEWAY DR, SUITE 116, TUKWILA, WA
Contractor:
Name: M M I SERVICES INC
Address: 245 S SUNSET WAY, ISSAQUAH WA
Contractor License No: MMISEI*094P5
DESCRIPTION OF WORK:
REMOVE NON - BEARING, NON -RATED DEMISING WALL, AND REMOVE NON - BEARING STORAGE ROOM; INSTALL NEW
NON- BEARING OFFICE WALLS; ENCLOSE EXISTING 900 SF CABINET SHOP TO ROOF DECK
Value of Construction:
Type of Fire Protection:
Type of Construction:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant:
Flood Control Zone:
Hauling:
Land Altering:
Landscape Irrigation:
Moving Oversize Load:
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter:
doc: Devperm
$ $23,000.00
SPRINKLERS
VN
Public Works Activities:
N
N
N
N
N
N
N
N
N
N
N
N
DEVELOPMENT PERMIT
Number: 0
Start Time:
Volumes: Cut
Start Time:
Private: N
Profit: N
Private: N
D03 -205
Permit Number:
Issue Date:
Permit Expires On:
Phone:
Phone: 206 433 -8997
Phone: 425 369 -8655
Expiration Date:03 /04/2004
Fees Collected: $603.86
Uniform Building Code Edition: 1997
Occupancy per UBC: 0016
Size (Inches): 0
End Time:
0 c.y. Fill 0 c.y.
End Time:
Public: N
Non - Profit: N
Public: N
D03 -205
08/05/2003
02/01/2004
Printed: 08 -05 -2003
Print Name:
doc: Devperm
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Permit Center Authorized Signature: - /i0/ a.}1 - - `e
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws
regulating construction or the performance of work. I am authorized to sign and obtain this development permit.
Ale 3
Signature: Date:
McG7hAa
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is
suspended or abandoned for a period of 180 days from the last inspection.
D03 -205
Date: C)f h 3 (c 3
Printed: 08 -05 -2003
4.1tE?RiuTt -p7
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Parcel No.: 0323049164 Permit Number: D03 -205
Address: 10828 EAST MARGINAL WY S TUKW Status: ISSUED
Suite No: Applied Date: 07/10/2003
Tenant: GENE JUAREZ CORPORATION Issue Date: 08/05/2003
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division.
3: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical
work will be inspected by that agency (206- 835 - 1111).
4: All mechanical work shall be under separate permit issued by the City of Tukwila.
5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any
construction. These documents are to be maintained and available until final inspection approval is granted.
6: Any new ceiling grid and Tight fixture installation is required to meet lateral bracing requirements for Seismic Zone 3.
7: Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length.
8: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997
Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition).
9: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be
construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any
other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this
code shall be valid.
10: ** *FIRE DEPARTMENT CONDITIONS * **
11: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following
concerns:
12: ** *FIRE EXTINGUISHERS * ** - UFC Article 10 and NFPA 10.
13: The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000
sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to
any fire extinguisher must be 75' or Tess. (NFPA 10, 3 -1.1)
14: Maintain fire extinguisher coverage throughout.
doc: Conditions
PERMIT CONDITIONS
15: Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors
shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of
an approved type. (UFC 1207.3)
16: Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207 -1212)
17: When two or more exits from a story are required, exit signs shall be installed at the required exits and where
D03 -205
Printed: 06 -14 -2004
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
otherwise necessary to clearly indicate the direction of egress. (UBC 1003.2.8.2)
18: Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible
route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1)
19: All exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 1
1/2 hours in case of primary power Toss, the exit signs shall also be connected to an emergency electrical system
provided from storage batteries, unit equipment or an on site generator set, and the system shall be installed in
accordance with the electrical code. (UBC 1003.2.8.5)
20: Maintian sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating
and /or adding sprinkler heads.
21: Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions
and under overhangs greater than four feet wide. (NFPA 13- 4- 5.5.3.1)
22: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and
approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler
systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk
Insurers, Kemper or any other representative designated and /or recorgnized by the City of Tukwila, prior to submittal
to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance
#1901)
23: All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70)
24: Contact the Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance
#1900 and #1901)
25: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
26: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
doc: Conditions
* *continued on next page **
D03 -205
Printed: 06 -14 -2004
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any
regulating construction or the performance of work.
Print Name: � l�h Z. ft"
doc: Conditions
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
D03 -205
of law and ordinances
other work or local laws
Signature: � l Date: 4 ray O
Printed: 06 -14 -2004
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
PERMIT CONDITIONS
z
1 z
'~ W
J
UO
J =
H
W
W¢
= • a
W
Z =
F— O
Z F—
W
• W
U�
O N
CI F—
W • W
F— H
• O
w z
O —
F-
O /—
9: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be z
construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any
other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this
code shall be valid.
Parcel No.: 0323049164 Permit Number: D03 -205
Address: 10828 EAST MARGINAL WY S TUKW Status: ISSUED
Suite No: Applied Date: 07/10/2003
Tenant: GENE JUAREZ CORPORATION Issue Date: 08/05/2003
1: ***BUILDING DEPARTMENT CONDITIONS * **
2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division.
3: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical
work will be inspected by that agency (206- 835 - 1111).
4: All mechanical work shall be under separate permit issued by the City of Tukwila.
5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any
construction. These documents are to be maintained and available until final inspection approval is granted.
6: Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3.
7: Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length.
8: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997
Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition).
10: ** *FIRE DEPARTMENT CONDITIONS * **
11: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following
concerns:
12: ** *FIRE EXTINGUISHERS * ** - UFC Article 10 and NFPA 10.
13: The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000
sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to
any fire extinguisher must be 75' or Tess. (NFPA 10, 3 -1.1)
14: Maintain fire extinguisher coverage throughout.
15: Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors
shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of
an approved type. (UFC 1207.3)
16: Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207 -1212)
17: When two or more exits from a story are required, exit signs shall be installed at the required exits and where
otherwise necessary to clearly indicate the direction of egress. (UBC 1003.2.8.2)
doc: Conditions
D03 -205
Printed: 08 -05 -2003
''IOW%
18: Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible
route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1)
19: All exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 1
1/2 hours in case of primary power loss, the exit signs shall also be connected to an emergency electrical system
provided from storage batteries, unit equipment or an on site generator set, and the system shall be installed in
accordance with the electrical code. (UBC 1003.2.8.5)
20: Maintian sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating
and /or adding sprinkler heads.
21: Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions
and under overhangs greater than four feet wide. (NFPA 13 -4- 5.5.3.1)
22: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and
approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler
systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk
Insurers, Kemper or any other representative designated and /or recorgnized by the City of Tukwila, prior to submittal
to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance
#1901)
23: All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70)
24: Contact the Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance
#1900 and #1901)
25: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
26: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws
regulating construction or the performance of work.
Signature: � �^-� Date: 875763
Print Name:
doc: Conditions
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
D03 -205
Printed: 08 -05 -2003
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
Site Address:
Tenant Name:
ave
Property Owners Name: H Y CAL co. [tic.
Mailing Address: CCU /keellowe to% Stiffs IoI
Name: tzoo II X LE c 11
Mailing Address: L2i1,ic £ Pi. Sift' l a
ONTACT PERSON
•
E -Mail Address:
GENERAL CONTRACTOR INFORMATI
Company Name: RH
Mailing Address: 1.44
Contact Person: eautil
E -Mail Address:
t, G1p
Company Name: 3it 10614106 / IVOR
Mailing Address: 1 7A7 E 1./i. 1 V(g
Contact Person: 12\110 16E41,6
;ENGINEER OF- RECORD All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
\applications\permit application (3-2003)
3/2003
µ�k
Page 1
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
Cit
King Co Assessor's Tax No.:
Suite Number:
New Tenant: ❑ .... Yes
h13.
State , .. Zip
Day Telephone: ' T • 4-3:3-b41
Wb . cOneor
City State Zip
Fax Number: 'O- ttlik4M1
tg..No
State Zip
Day Telephone: •• %4 Sta:
City
Fax Number:
E -Mail Address:
Contractor Registration Number: i.e.. L 1* 0 f y Expiration Date: e$31
* *An original or notarized copy of current Washington State Contractor License must be presented at the time of pennit issuance **
.,::ARCHITECT OF RECORD. .= All: plans must be wet stamped by Arcliitect. Record
* w . agloc
City State Zip
Day Telephone: tag • Pj
Fax Number: o.'t4 Q- F57{061
State
Zip
City
Day Telephone:
Fax Number:
DING PERMIT•INFORM4, ION 206 431 -3670
Valuation of Project (contractor's bid price): $ C. Existing Building Valuation: $
Scope of Work (please provide detailed information): VC�' ast. I1O - Mitii..kt 1 ti' 149 l /
E. frfAtig
• b r... L.
Will there be new rack storage? 0 ..Yes N.. No If "yes ", see Handout No. for requirements.
Ztsic " 2 Pii4"
All Building Areas in Square Footage Below rt
�t�J�IG�Pe'
1' ;
2 Floor
3f Floor:
• Floors: • • :thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
• Detached Carport
•Covered Deck
Uncovered. Deck.
Interior
Remodel
Addition to
Existing.
Structure.
Type of
Construction
per, UBC .
Type of
Occupancy per
UBC.
h1 i t
1 0P
PLANNING DIVISION:
Single- family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? [] ....Yes /gt..No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
y gl.. Sprinklers Ei ..Automatic Fire Alarm 0..None 0.Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes .No
If "yes", attach list of materials and storage locations on a separate 8-1/2 x 11 paper indicating quantities and Material afety Data Sheets.
lapplications \permit application (3.2003)
3/2003
Page 2
Water District
❑ ...Tukwila ❑... Water District #125
❑ ...Water Availability Provided
Submitted with Application (mark boxes which apply):
❑ ...Civil Plans (Maximum Paper Size — 22" x 34 ")
❑ ...Technical Information Report (Storm Drainage)
❑ ...Bond ❑ .. Insurance ❑ .. Easement(s)
�ORKSPER .MIT�INT"��t.MATION:'�'
1-i i f1 t11 i
Proposed Activities (mark boxes that apply):
❑ ...Right -of -way Use - Nonprofit for less than 72 hours
❑ ...Right -of -way Use - No Disturbance
❑ ...Construction/Excavation/Fill - Right -of -way
Non Right -of -way
❑...Total Cut
❑ ...Total Fill
cubic yards
cubic yards
❑ ..:Sanitary Side Sewer
❑ ...Cap or Remove Utilities
❑ ...Frontage Improvements
❑ ...Traffic Control
❑ ...Backflow Prevention - Fire Protection
Irrigation
Domestic Water
\applicationslpennit application (3 -2003)
3/2003
❑ ,. Abandon Septic Tank
❑ ,. Curb Cut
❑ .. Pavement Cut
❑ .. Looped Fire Line
„
„
❑ ...Permanent Water Meter Size... 12 WO#
❑ ...Temporary Water Meter Size.. 1 1 WO#
❑ ...Water Only Meter Size WO#
❑ .,.Sewer Main Extension Public Private
❑ ...Water Main Extension Public Private
Page 3
06=:433 =01
Scope of Work (please provide detailed information):
Call before you Dig: 1- 800 - 424 -5555
Please refer to Public Works Bulletin #1 for fees and estimate sheet.
❑ .. Highline
❑ ...Renton
Sewer District
❑ ...Tukwila ❑ .,. ValVue ❑ .. Renton ❑ ...Seattle
❑ ..,Sewer Use Certificate 0... Sewer Availability Provided ❑ .. Approved Septic Plans Provided
❑ ...Septic System - For onsite septic system, provide 2 copies of a current septic design approval by King County Health Department.
❑ ., Geotechnical Report ❑...Traffic Impact Analysis
❑ .. Maintenance Agreement(s) 0... Hold Harmless
❑ .. Right -of -way Use - Profit for less than 72 hours
❑ .. Right -of -way Use — Potential Disturbance
0 .. Work in Flood Zone
❑ .. Storm Drainage
❑ .. Grease Interceptor
❑ .. Channelization
❑ .. Trench Excavation
❑ .. Utility Undergrounding
❑ ,..Deduct Water Meter Size "
FINANCE INFORMATION
Fire Line Size at Property Line Number of Public Fire Hydrant(s)
❑ ...Water
❑ ... Sewer ❑ ... Sewage Treatment
Monthly Service Billing to:
Name:
Mailing Address:
City State Zip
Day Telephone:
Water Meter Refund /Billing:
Name:
Mailing Address:
State Zip
Day Telephone:
City
Unit Type:
Qty
Unit Type:
Qty
Unit Type:
Qty
Boiler /Compressor:
Qty
Furnace <100K BTU
Air Handling Unit
>= 10,000 CFM
Other Mechanical
Equipment
0 -3 HP /100,000 BTU
Furnace>I00K BTU
Evaporator Cooler
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan
15 -30 HP /1,000,000 BTU
Suspended /Wall /Floor
Mounted Heater
Ventilation System
30 -50 HP /1,750,000 BTU
Appliance Vent
Hood
50+ HP /1,750,000 BTU
Heat/Refrig/Cooling
System
Incinerator - Domestic
Air Handling Unit
<= 10,000 CFM
Incinerator — Comm /Ind
MECHANICAL PERMIT INFORMATION `= 206 -367 •
•
MECHANICAL CONTRACTOR INFORMATION
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
* *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance **
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detailed information):
Use: Residential: New .... Replacement ....D
Commercial: New ....0 Replacement ....
Fuel Type: Electric 0 Gas ....0 Other:
Indicate type of mechanical work being installed and the quantity below:
;PERMIT. APPLICATION NOTES - Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as
defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW TI-IE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING it grolATHORIZED AGENT:
Signature:
Print Name: libvi
Mailing Address: / ZO
\applications \permit application (3- 2003)
3/2003
eR2
Page 4
Day Telephone:- 433 - E
City
State
Date: 0 1110 1,03
State
Date Application Accepted:
2 /o -3
Date Application Expires:
— D1 1
Staff Initials:
1
Zip
Zip
N '!. .1'+; "Ya',fSf ;tY^.Q:ww';54iY'.i
Parcel No.:
Address:
Suite No:
Applicant:
Receipt No.:
Initials:
User ID:
Payee:
doc: Receipt
City of Tukwila
TRANSACTION LIST:
Type Method
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
0323049164
10828 EAST MARGINAL WY S TUKW
GENE 7UAREZ CORPORATION
R03 -00822
SKS
1165
DAVID E. KEHLE ARCHITECTS
Payment Check
Description
15637
RECEIPT
ACCOUNT ITEM LIST:
Description Account Code
PLAN CHECK - NONRES 000/345.830
Permit Number:
Status:
Applied Date:
Issue Date:
Payment Amount: 236.11
Payment Date: 07/10/2003 02:16 PM
Balance: $367.75
Amount
236.11
Current Pmts
236.11
Total: 236.11
D03 -205
PENDING
07/10/2003
07;9 07t'':1 9716 TOTAL :236 . 1,i
Printed: 07 -10 -2003
Z
H
• W;
J U
O 0
W I
W O.
Receipt No.: R03 -00957 Payment Amount: 367.75 g a
c
Initials: LAW Payment Date: 08/05/2003 12:13 PM = 0
User ID: 1630 Balance: $0.00 W
Z�
I- 0
Z I-
W uj
Do
O N'
TRANSACTION LIST: W W
Type Method Description Amount H U
LL O
Payment Check 5576 367.75 Z
W
— I
0
Z
Parcel No.: 0323049164 Permit Number: D03 -205
Address: 10828 EAST MARGINAL WY S TUKW Status: APPROVED
Suite No: Applied Date: 07/10/2003
Applicant: GENE JUAREZ CORPORATION Issue Date:
Payee: MMI SERVICES INC
ACCOUNT ITEM LIST:
doc: Receipt
City of Tukwila
Description
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
BUILDING - NONRES 000/322.100
STATE BUILDING SURCHARGE 000/386.904
RECEIPT
Account Code Current Pmts
363.25
4.50
Total: 367.75
.i2:;i OB/06 9716 TOTAL 7367.75
Printed: 08 -05 -2003
COMMENTS:
Type of Inspec n
0 .... ) 7'91,5> -7I /r t7 sS) S - /C.-14
1),G0/7 Z.'" 1?ee1Pit..}� %r' / mil" / fr/✓ ..C4+
Afar A / / (9 riI G ,2 / 7.../14 5 /-Avet
l am'.
D e Wanted: a.m.
) f (p.m
1
&.")'1--I 4-1.0.
Phone N :
� 5 - 7 i'5 - 910‘e(e
I
i
y t '
Pro' t:
Type of Inspec n
A re s:,.. J
0 ( C / , n14.r5. L,'
Date Called:
,5, I I f (r)-3 --
Special Instructions:
l am'.
D e Wanted: a.m.
) f (p.m
1
Requester:
�t" P
Phone N :
� 5 - 7 i'5 - 910‘e(e
.':'iinJx {ti:,: i.''v�- jh4�.'a:k'::`.v L'�vrri.'i:s, .:. is4 ''is�'it^7,:.::.•.•,.i:i...�;:,
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
Approved per applicable codes.
I spe
INSPECTION NO.
Rec 10 No.:
INSPECTION RECORD
Retain a copy with permit
Date:
.0 D-37;05
PER
•
( 06)431 -3670
Corrections required prior to approval.
Date:
1 4 ` / / fp- -4? 3
.00 REINSPECTiON FEE REQUIRE . Prior to inspection, fee must be
4(d at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Project:
(i J Q a
Type of In pection: ( r, �
i( . I, U 7 i I (1./4C
1 dc � a
� . 1(1k
-./
Dat C
. 1 - 7/v 3
Special Instructions:
'Date Wanted:
1 aieV / j „: p.m.
Requester: /
k- 5 ta -e'LI 3.r�..t
Phone No:
1 °5iS i 8OR
INSPECTfaN NO.
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
1)03
El $47.00 REINSPECTI FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
D ate
Receipt No.:
Date:
P eject:'
Type f Inspection: •
Address' -
70 ,',2erf e7—filla; W ..5.-
Date Called:
w)i.e.:77703
Special Instructions:
Date Wanted:
;1
a,
Requester:
Phone No:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
MENTS:
Approved per applicable codes. ❑ Corrections required prior to approval.
$47.00 REINSPE N FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
4
Project:
Type of Inspection:
Address:
108,1F3
2 , O n AQ61 IJi L -
Date Called:
+& S
i ( — I L /-- t
r=�-
Special Instructions:
Date Wanted:
u —,4-
03
m,
i
Requester:
Awl
Phone No:�
c, Li 2 5
/
7 [=�
-.96°66
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Approved per applicable codes. Corrections required prior to approval.
$47.00 REINSPECTION FEE REARED. Prior to inspection, fee must be
paid at 300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt.No.:
Date:
COMMENTS:
b)/, /67 f
•=> /" C vet // . / 3
> 6e, . 7/9 1
Y! ' /
gee"' l 1 e
a
w
QQ • �
JU
U O
CO
W=
J
�
w 00
g J
u_ ?
u d
= W
F-
Z�.
Z UJ
w
U�
w
0I-
WW
0 .=
• Z
W
U =
0
2
Pr,o.�►�ct:
Type of Inspection:
Address �
Date Called: n
/
Special Instructions:
S
ti y s
r�
A e4 �
Date Wanted:
C.a.m.
Requester
t . �
Ph one / ___:\
1 IA? 5
_
3a -
/ O
1-
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMI
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
a pproved per applicable codes.
Do 3 -ac
Corrections required prior to approval.
COMMENTS:
C/7) 6 -f°,'r /
Date:
.00 REINSPECTION F:E REQUIRED. Prior 10 inspection, fee must be
aid at 6300 Southcente Blvd., Suite 100. Cal to schedule reinspection.
Receipt No.:
Date:
Prom 1
(1 --) l'faite3
Type ofjaspection:
.
Address:
iDfrUg E . Illery
Date Called:
WE r Van'ted•
010?
Special Ins/ructions:
/
I S (
1
1
1 U
Requ er: •
a Mel (
Phcalello:\
VO -" tiO 7")( ,
r 10,7,^t , -
. . . .
. „
•
t.
E2 Approved per applicable codes.
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
• CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670
.1■•••••••••
COMMENTS:
,„.
Ins ctor:
)
CA.A.kk
47.00 REINSPECT ON FEE REQUIR
aid at 6300 Southcenter Blvd., Suit
ipt No.:
Date:
) —
D. Prior to inspection, fee must be
100. Call to schedule reinspection.
Date:
El Corrections required prior to approval.
'RO5
y
-
. •
Sprinklers:
• Fire Alarm:
• Hood & Duct:
Halon:
• Monitor:
Pre-Fire:
Permits:
Authorized Signature
FINALAPP.FRM
t
City of Tukwila
Fire Department
().
Rev. 2/19/98
7;0,7;4'117:417 7. 41 " Trno '
'1;4". '4 A r • 144.7,Z(77 ; 7717::
r „
TUKWILA FIRE DEPARTMENT
FINAL APPROVAL FORM
Project Name A
•
Address • e •
:cur i.4.nspect±o schedule .
Needs shift inspection
\/. Approved without correction notice
• Approved with correction notice issued
,
Steven M. Mullet, Mayor
Thomas P Keefe, Fire Chief
Date
_
Permit No. I
Suite #
T.F.D. Form F.P. 85
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575-4439
09 -07 -2004
DAVID KEHLE
12720 GATEWAY DR, SUITE 116
TUKWILA, WA 98168
RE: Permit Application No. D03 -205
10828 EAST MARGINAL WY S TUKW
Dear Permit Holder:
In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division.
Per the International Building Code and /or the International Mechanical Code, every permit issued by the Building Division under the
provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not
commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or
abandoned at any time after the work is commenced for a period of 180 days.
Based on the above, you are hereby advised to:
Call the City of Tukwila Permit Center at 206 -431 -3670 to arrange for the next final inspection.
This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if
the project should be considered abandoned.
If such determination is made, the Building Code does allow the Building Official to approve a one - tine extension up to 180 days.
Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have
prevented action from being taken.
In the event you do not call for the above inspection and receive an extension prior to 10/22/2004, your permit will become null and
void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Stefania Spencer,
Permit Technician
xc: Permit File No. D03 -205
Bob Benedicto, Building Official
City of Tukwila
Steven M. Mullet, Mayor
Department of Community Development Steve Lancaster, Director
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
Space Heat Type
0 Electric resistance 0 All other (see over for definitions)
Glazing Area Calculation
Note: Below grade walls may be included in the
Gross Exterior Wall Area if they are insulated to
the level required for opaque walls.
Total Glazing Area Electronic version: these values are automatically taken from ENV -UA -1.
(rough opening) Gross Exterior
(vertical & overhd) divided by Wall Area times 100 equals % Glazing
T X 1 00
Concrete/Masonry Option
O yes Check here if using this option and if project meets all requirements for the ConcretelMasonry
Option. See Decision Flowchart (over) for qualifications. Enter requirements for each aua tying,,,;.,..,
O no
assembly below. I r" t t r- r nDV
Project Info
Project Address 1 0'
1.l
t ro ii J j _ i..
-=('
•
Date eZ LLJ
Q9
For Building r� *ase
i , OF TUKWIIA
J U L 1 0 2003
PERMIT CENTER
Applicant Name:
David Kehle Architect
Applicant Address:
12720 Gateway Drive su 116
Applicant Phone:
(206) 433 -8997
2001 Washington State Nonresidential Energy Code Compliance Forms
Project Description
Envelope Requirements (enter values as applicable)
Fully heated/cooled space
Minimum Insulation R- values
Roofs Over Attic
All Other Roofs
Opaque Walls
Below Grade Walls
Floors Over Unconditioned Space
Slabs -on -Grade
Radiant Floors
Opaque Doors
Vertical Glazing
Overhead Glazing
Maximum U- factors
Maximum SHGC (or SC)
Vertical/Overhead Glazing
Semi- heated space 2
Minimum Insulation R- values
Roofs Over Semi - Heated Spaces
2001 Washington State Nonresidential Energy Code Compliance Form
Envelope Summary
Climate Zone 1,
ENV -SUM
❑ New Building ❑ Addition
Compliance Option
❑ Prescriptive ❑ Component Performance
(See Decision Flowchart (over) for qualifications)
❑ ENVSTD 2.1 ❑ Systems
(4.0 not acceptable) Analysis
1. Assemblies with metal framing must comply with overall U- factors
2. Refer to Section 1310 for qualifications and requirements
Notes: No hitv Walt*
O Alteration ❑ Change of Use
Opaque Concrete/Masonry . Wall Requirements
Insulation on interior - maximum U- factor is 0.19
Insulation on exterior or integral - maximum U- factor is 0.25
If project qualifies for Concrete /Masonry Option, list walls
with HC ? 9.0 Btu/ft °F below (other walls must meet
Opaque Wail requirements). Use descriptions and values
from Table 20-5b in the Code.
Wall Description
(Including insulation R -value & position)
U- factor
caIY OF WOO
:t:kzo5!
b
First Edition, June 2001
Project Info
Project Address [(2b2.45 p , /t �� 1 t t f
Y.Q L{DL-
Date./ 1 1^
Watts/
Fixture
athE
��P
Covered Parking
(standard paint)
For Building DDeliltirIl e
OI V OF TU WIl.A
JUL 1 0 2003
PERMIT CENTER
y
Applicant Name: David Kehle Architect
Applicant Address: 12720 Gateway Drive Su
116
Applicant Phone: (306) 433 -8997
Open Parking
Location
Fixture Description
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
Covered Parking
(standard paint)
Gm t* T1
0.2 W /ft
Covered Parking
(reflective paint)
0.3 W/ft
Open Parking
� !!tt
v L 1 Zu03
0.2 W /ft
Alteration Exceptions
(check appropriate box)
.
changes are being made to the lighting
• Less than 60% of the factures are new, and installed lighting wattage is not b9inQjperpagpd
Location
(floor /room no.)
_ 11
Occupancy Description ,
Pa Y
o ` �t t
�
W atts per � � "
?r;k
�'� A ra in f C
A rea �
agnrovals are
Allowed x Area
Covered Parking
(standard paint)
Gm t* T1
0.2 W /ft
Covered Parking
(reflective paint)
0.3 W/ft
Open Parking
� !!tt
v L 1 Zu03
0.2 W /ft
" From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts
) V
Location
(floor /room no.)
Fixture Description
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
Covered Parking
(standard paint)
Gm t* T1
0.2 W /ft
Covered Parking
(reflective paint)
0.3 W/ft
Open Parking
� !!tt
v L 1 Zu03
0.2 W /ft
Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts
) V
Location
Description
Allowed Watts
per ft or per If
Area in ft
(or If for perimeter)
Allowed Watts
x ft2 (or x If)
Covered Parking
(standard paint)
Gm t* T1
0.2 W /ft
Covered Parking
(reflective paint)
0.3 W/ft
Open Parking
� !!tt
v L 1 Zu03
0.2 W /ft
Outdoor Areas
) V
0.2 W /ft
Bldg. (by facade)
0.25 W /ft
Bldg. (by Perim)
7.5 W /If
Note: for building exterior, choose either the facade area or the perimeter method, but not both) Total Allowed Watts
Lighting Summary
LTG -SUM
2001 Washington State Nonresidential Energy Code Compliance Forms
Project Description
❑ New Building ❑ Addition • Alteration El Plans Included
Refer to WSEC Section 1513 for controls and commissioning requirements.
Compliance Option
2001 Washington State Nonresidential Energy Code Compliance Form
Maximum Allowed Lighting Wattage (Interior
0 Prescriptive Q Lighting Power Allowance Q Systems Analysis
(See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.)
FILE C
June 2001 - KJM
Notes:
1. Use manufacturer's listed maximum input wattage. For hard -wired ballasts only, the
default table in the NREC Technical Reference Manual may also be used
2. Include exit lights unless Tess than 5 watts per fixture.
Proposed Lighting Wattage (Interib)st all fixtures. For exempt lighting, not exception and leave Watts/Fixture blank.
Maximum Allowed Lighting Wattage (Exterior)
wattage. hor textures wtth hara -wlrea oallasts only,
Proposed Lighting Wattage (Exterior) the default table in the NREC Technical Reference Manual may also be used.
May 18 04 03:58p p.1
MMi Services, Inc
P. 0. Box 2768
Issaquah, WA 98027
425 369 -8655
May 18, 2004
z
_
,*"w
. �
e
J
0 0
N
W I
J 1-,
N u_
u 0
u.¢
z a
1 ._W
m.
z 1-.
1- a
z 1-.
Gordon Moorman ^>'� = 0
�� 1•- v,
President q 1 - ~
,� tii z .
A
CCp_ C � � O U =
o o
City of Tukwila
6300 Southcenter BL, Suite 100
Tukwila, WA 98188
Attn: Stephania Spencer
Re: Gene Juarez
Permit # D03 -205
Dear Stephania:
Please extend the duration of the above permit due to delays in the project.
Thank you
5/Zvp
4.qr/444 180c=
1 ` . '&
Lic. # MMISEI *094P5
z
April 6, 2004
David Kehle
12720 Gateway Drive, Ste 116
Tukwila, WA 98168
RE: Permit Application No. D03 -205
10828 East Marginal Way South
Dear Permit Holder:
Cii of Tukwila
Department of Community Development Steve Lancaster, Director
In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila
Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the
Building Official under the provisions of this code shall expire by limitation and become null and void if the
building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if
the building or work authorized by such permit is suspended or abandoned at any time after the work is
commenced for a period of 180 days.
Based on the above, you are hereby advised to:
• CaII the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next or final
inspection.
This inspection is intended to determine if substantial work has been accomplished since issuance of the permit
or last inspection; or if the project should be considered abandoned.
If such determination is made, the Building Code does allow the Building Official to approve a one -time
extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why
circumstances beyond the applicants control have prevented action from being taken.
In the event you do not call for the above inspection or request and receive an extension prior to May 22, 2004,
your permit will become null and void and any further work on the project will require a new permit and
associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Stefania Spencer
Permit Technician
Xc: Permit File No. D03 -205
Bob Benedicto, Building Official
Steven M. Mullet, Mayor
6300 Southcenter Boulevard, Suite /1100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 - 431 -3665
ACTIVITY NUMBER: D03 -205 DATE: 07 -11 -03
PROJECT NAME: GENE JUAREZ CORPORATION
SITE ADDRESS: 10828 EAST MARGINAL WY S
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Is Issued
Aw G
,� A'U�� . j 16,1-0-05
Buildin' g bivision [� Fire revention
Public W � /1D3 Structural ❑
DEPARTMENTS: 1-15tS
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 07 -15 -03
Complete
PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
Incomplete ❑
apt_ itL 146
Planning Division
kr Permit Coordinator
Not Applicable ❑
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS R�TING:
Please Route Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
DUE DATE: 08 -12 -03
Approved ❑ Approved with Conditions [ Not Approved (attach comments) ❑
Notation:
APPROVALS OR CORRECTIONS:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28.02
PERMIT COORD COPY
ti liusi::.} :;:.�S:::il.=.'irlSti+j.�Y rxtCa Far..- ril s. y53:.ti4C L bYw.�' Gk.. u:« +'+:ti.irtid...XLLO.wi�2:t.:e:t+.:
Jul 10 03 07:57a p.2
F625.052.000 (R197)
JUL 10 2003
DAV1f) ? <EHLE \:?( i"FC
DEPARTMENT OF LABOR AND INDUSTRII3S
REGISTERED AS PROVIDED BY LAW AS
CONST CONT GENERAL
REGIST. # .. EXP. DATE
CC07:MMISEI *„p94P5 03/04/2004
EFFECTIVE'DATE "' 10/25/1991
M M I,SERVICES INC
245' S ' SUNSET WAY
ISSAQUAH.WA 98027'
k
RECEIV
CITY OF TUK WILA
JUL 1 0 2003
PERMIT CENTER
bO3
de
•1 1
7'
. •
,4T
1
•
• •
��s
�I, s I.
•
•
•
•
•
., •
"Wt • f • R
‘„
•
•
•
• . y • Q „,. *L . .
�rEo4- r
_ G �, j.
c_G • s f 0A
Fir, • "b
1
•
NORTH
•
.•■
w`
Ifitocx
•
no
Ma
‘6 .
VICINITY MAP
NOT TO SCALE
�
6
` ,r
C •
Jam ..
PROPERTY TAX ACCOUNT NUMBER
. 1
‘6
032304- 9164 -09
1
.l't
W P
SITE PLAN
o"
•
` r
• „1
S
��y
� �R0P
�S
W ��
•
• .
•
•
•
•
•
•
•
BUILDING Sc SITE STATISTICS
-SIZE AREA
-LOT F= APPROXIMATELY 54,870 S.F.
-LOT G= APPROXIMATELY 129,800 S.F.
-TOTAL= APPROXIMATELY 184,670 S.F.
- BUILDING AREA
-TOTAL BUILDING= 89,340 S.F.
TENANT SPACETHIS PERMIT -NO CHANGE OF USES
EXISTING OFFICE= 674 S.F.
EXISTING MANUFACTURING= 903 S.F.
EXISTING WAREHOUSE= 13,923 S.F.
TOTAL TENANT SPACE= 15,500 S.F.
- PARKING PROVIDED = 121
-ZONING: MIC /4i4
-TYPE OF CONSTRUCTION: V -N
-OCCUPANCY GROUPS: Si, F1, & B
-BUILDING CODE: 1997 UBC
•
P I
>741g �R
70 �O.
ti
o
LEGAL
TWAT PORTION OF TNI SOUTH /EST QUARTO OF SECTION 3, . TONNSIWIP
$3 NORT1, RANGE 4 EAST, W.N., IN RING COUNTY, WASHINGTON,
DESCRIBED AS FOLLOWS:
NOGINIIIIIS AT TRt INTERSBCM'IOU or THE EASTERLY MARGIN Or EAST
MARGINAL WAY Mn'N, AND !'NS SCUTS LIME OF SAID SECTION 3:
TNENCI MOWS SAID MANN= NOME 14'47 NEST 444.40 FEET TO
TMR TRIUR POINT Or $EGIMIIWIIWGI
'rwENCI CONTINUING ALONG SAID MARGIN NORTH 14'47'30 UEST
aoo.00 ram
TxEI1CS WORTS 73'12°30 FIST TO Till WESTERLY BOUNDARY OF
PUGS! SOUND POKIER AND LIGET RIGHT-O!' -NAT. rmaNE'RLT SEATTLE-
TACOMA INTERURBAN RAILWAY RIGIFt -O /-MAT s
TNENCZ SOLI NERLY ALONG SAID BOUNDARY TO A LINE MICR BEARS
WORTS 73 EAST FROM TKO TWO POINT OF BEGINNING.:
'rxmi S 60WMI 73'12°30° NEST TO TR* TRUS POUR OF BEGINNING.
• PARCEL G:
EXCEPT TWAT PORTION DESCRIBED AS FOLLOWS:
•
By
Dat
Permit No.
DESCR IPTIONS
THAT PORTION or TNS sOUi71WCST QUARTER OF SECTION 3, TOWNSHIP
23 NORTH, RANGE 4 LAST, M.N., IN RING COUNTY, WASNINGTOWI,
DESCRIBED AS FOLLOWS:
BEGINNING AT TI1R INTERSECTION OF THE EASTERLY MARGIN OF EASE
,MARGINAL WAY, RAVING A RIGHT ANGLIA WID111 OF 40 FEET, W1TR
TIM ROUTE LINE OF SAID SECTION 3, SAID POINT BEING 411.792
FEET, HOGS OR LESS, EASTERLY OF TMs SOUTHWEST CORNER OF SAID
SECTION,
THENCE SOOT, 89'47'20 EAST ALONG SAID SECTION LINE 324.788
FEET, MOOS OR LLZI, TO THS NEST SUA BOUNDARY LINE OF PUGET
SOUND POWER AND LIGET COMPANY RIGHT -OF -MAY, FORMERLY
SEATTLZ- TACOMA INTERURBAN MAMMY RIGHT-OT -MAY:
THEMES FOLLOWING SAID WESTERLY BOUNDARY OW THE ARC OF A
CURVE TO TER LEFT RAVING A RADIUS OF 2814.93 FEET AND TMR
LONG CHORD OF MICR BEARS WORT M 18"15 WEST, 3S9.985 FEET
TO A POINT OF TANGENCY:
THENCZ OOmmorma ALONG SAID BOUNDARY POSTS 21'53°50° WEST
333.SO FEET TO A POINT OF A CURVE,
•n[ i = ALONG SAID BOUNDARY 011 TIE ARC OF A CURVE TO TRR!
RIGHT WEAVING A RADIUS OF 2914.93 FEET AND THE LONG CHORD OF
wHICN BEARS NORTR 14'28'3:• %EST. AN AMC DISTANCE OF 400
PEST, MONK OR LESS, TO THZ ROUTE LINE or A TRACT DESCRIBED
IN MODIFICATION OF CONTRACT RECORDED UNDER RECORDING NO.
19463441 SAID POINT ALSO BEING THE MORTIS LINE OF AN EXISTING
PPIVATI ROADWAY:
woe= ROUTE 79"12°30 NEST ALCI G SAID SOUTI1ERLY LINN 232
mum, HORN OR LESS, TO TIM SOUTHEASTERLY CORNER Or A TRACT
CONDQOIED FOR MAD UNDER XING COUNTY SUPERIOR COURT CAM
NO. 353823:
L TWIN= MONTS 89'37'30° NEST AIMING TIR $OUTW LINE OF SAID
TRACT 31.4 FEET TO A POINT ON TEE EASTERLY MARGIN OF EAST
MARGINAL WATT
THENCE SOiT:N 14'47'30• EAST 1420 FELT MORE OR LESS, ALONG
,SAID EASTERLY RARGIW To TUN PLACE OF BEGINNING:
COIO4EMICIIIG AT A POINT OW TN! EASTERLY BOUNDARY LINE OP EAST
MARGINAL MAT SAID POUT BEARS NORTE 14'47'30 %RS? 1387.1218
FEET FROM TWE POINT WWFTS TNS SAID EAST BOUNDARY LINZ
INTERSECTS TIM SOtTIR BOI:NDART LINE Or SAID SECTION 3;
RUNNING TNENCS •OUTS 14'47'30 EAST AUM G SAID EAST MAMIGIWAL
LINE 192.529 FEET;
TWICE CE SOUIR 89'37°30 EAST 2)2.103 FEET TO A POINT 70 FEE'?
DISTANCE FROM THE CENTER LINE OF SEATTLE- TACOMA INTERURBAN
RAILWAY;
' THENCE OW TNS MC OF A cum mimeo A RADIUS Or 2934.92 FEET
ALONG THI WEST BOUNDARY LINE OF A CERTAIN LANE AND PARALLEL
TO SAID CENTER LINE, Till LONG CHORD OF WHIM ARC BEARS PORTS
13'24'13 WEST 189.402 FEET;
TIED= NOTE 89'37 NEST ALONG THIS SOUR BOUNDARY LINE or
A CERTAIN PRIVATE ROAD 243.819 FEET TO T111 PLACE OF
MIMING. 11
• i • ALSO , ..
EXCEPT TWZRZMIO N TWA? PORTIOW THEREOF LYING SOUTHERLY OF TOR
FOL.LOW/NG DESCMIBED LENSES:
**GINNING AT TAR INTERSECTION OF TN! EASTERLY MARGIN OF EAST
MARGINAL WAY SUITES AND T1 SOWN LAWS OF SAID SECTION 3,
=ONCE ALONG SAID MANGIM NORTE 16'47•30• NEST 444.40 FEE? TO
TH! TRUR POINT OF BEGINNING:
Tfl lC! PORT! 73'12'30° EAST TO THI wZSTERL1 BOUNDARY OF TN!
PUGILT SOUND POWER AND LIGHT RIGHT -OF -MAT, FORMERLY SEATlLZ-
TALOMA INTERURBAN RAILWAY RIGHT-OF-NAY, AND THZ TERHINUI or
SAID L.INZ.
FILE COPY
I understand that the Plan Check approvals are
subject to errors and omissions and approval of
plans does not authc-rite the violation of any
adopted code or ordinance. Receipt of con-
tractor's copy of approved plans acknowledged.
SEPARATE PERMIT
REQUIRED FOR:
le MECHANICAL
[ g ELECTRICAL
LPLUMBING
g„ GAS PIPING
CITY OF TUKWILA
BUILDING DIVISION
R EVISIO I4 S virmrol giop
APPROVAL OF lUICWILA BUISDiet! suo.014100,4
114E SCOPE OF WORK
1101110.0 WAX INCA016 A NIP/ PAP
Aye Wm oroLuoi fitiAM NNW/ Via
memo
COY of TUcwiu►
JUL 1 1 ap
PERMIT COTES
1)03G-
tf
•
.00. WA
4 OW
At
l<6
EXISTING DRIVE
SNIPPING
RECEIVING
1
STAGING
50'
y
REMOVE EXISTNG WALL
WAREHOUSE
Li xcuic Y
GROUP si
REMOVE EXISTING DEMISMG WALL
0
EX. Rfr
a
9
REMOVE EX. DEMISING WALL
1 10
EX. :- x. RR
REMOVE EXISTING 5II'MC 4
REPLACE W/ NEW STAINLESS
STEEL 4 GOOSE NECK FAUCET
EX. OPEN
ONCE
EXISTING PULL WEIGHT DEMISING
WALL, NO CI4ANGE
1
TOR
LOCK UP
kJ xcu.
GROUP 5t
EX. FACTORY AREA
[Pi OCCUPANCY GROUP = Fl
903 SF. NO OCCUPANCY
SEPARATION PER NOTE 5
ON TABLE 3-B 1991 UBC
w/ DUST COLLECTION
SYSTEM BY TENANT
•
FILM. CUCKOO
24 TOP FLAW
.4' GYP. eD. DOW Gar
2O • II' oc.
l FULL NEIGFlT WALL DEAD DETAIL PARALLEL TO PURt.IN
SCALE 1 v.
• 6wGtr» PD11.411 0111e
POW. =KM — .-
!)dm 2X.t:_ - :NNE.
Ralf. HEK IM.. 14E6D DETAIL FEWENDICULAR TO PURLN
SCALE 1 la°•I' •fD"
ATTACH BOTTOM PLATE
TO Cc*IC. FLOOR UV
POWER DRIVEN
Ablai01Qs AT 24' OTC.
2 V2' RU38ER
BASE • CARPET
WALL DETAIL
SCALE 1 V2'•I' -0"
tcP cP ORACKEY
5/6' GYP. O. BON SIDES
2X4.24' OTC.
WALL TYPE SCHEDULE
in EXISTING CONCRETE WALL, NO CHANGE.
co EXISTING PARTIAL HEIGHT STUD WALL, 2X4 0 16" O.0 INSTALL DIAGONAL 2X4 BRACES 0 4' -0" O.C. FROM TOP
PLATE BACK ''08 ROOF STRUCTURE. INSTALL NEW STUD WALL ON TOP OF EXISTING WALT., 5/8" GYP. 9D. 90TH
SIDES 2X4 0 16' O.C., DETAILS 1/T -1 & 2/T -I.
® EXISTING STUD WALL, NO CHANGE.
w REMOVE EXISTING V/OOD CASING FROM HEAD & JAMBS FROM OPENING, MILL OPENING w/ 5/8' GYP. B0. BOTH
SIDES 2X4 0 24' 0•C., FMASH SMOOTH & FLUSH, DETAIL 3/T -1.
O] EXISTING PARTIAL HEIGHT STUD WALL,, 2X4 0 16' O.C. W/ 5/8" GYP. BD. ONE SIDE. REMOVE TOP PLATE, INSTALL
NEVI FULL HEIGHT 2X6 STUDS TO UNDER SIDE OF ROOF STRUCTURE 016" O.0 ADJACENT TO EXISTING STUDS &
INSTALL 5/8' GYP. B0. BOTH SIDES FULL HEIGHT, FIRE TAPE, DETAILS 1/T -1 & 2/T -1.
DOOR SCHEDULE
DOOR E I : EXISTING 311 STOREFRONT DOOR
DOOR E 2 : COSTING 3'X7' INTERIOR WOOD DOOR
DOOR E 3 : EXISTING 3'X7' INTERIOR WOOD DOOR W/ PRIVACY LOCK
DOOR E 4 : EXISTING OVERHEAD DOOR
DOOR E s : EXISTING 3'X7' EXISTING HOLLOW METAL DOOR
DOUR E 6 : EXISTING PAIR 3'X7' INTERIOR WOOD DOORS W/ METAL JAMB, L.ATCHSET,
FLUSH BOLT, 2 WAIL. STOPS, ASTRAGAL 3 PAIR BUTTS, 2 SILENCERS
DOOR 1 : 3'X 7' SOLID CORE WOOD DOOR W/ WOOD JAMB, LOCKSET, 1 1/2 PAIR
BUTTS, WALL STOP, 3 S1LENCERS.
EXISTING GYP. BD. CEILING
CEILINGS, NO CND
EXISTING SUSPENDED
ACOUSTICAL CEILING
• 9I -9" AFF. (TYP.),
NO CHANGE
LEGEND
MX: IC
Ili MOM ill. 011111111,
et' l' 4'
a'
k REFLECTED CEILING PL4N RELECTED
SCALE: va • 1
EXISTING WALL
NEW STEEL SW WALL
EXISTING WALL TO BE REMOvED.
NEW DOOR
EXISTING DOOR
6CALE 1/8" • 1'40
� A
JUL 1 0 2113
PERMIT CENTER
PD2-o S
16 24' 32' 40'
V
. 07/08/2003 10:03 ari C: \CAD \0238— McCONKEY \T -1.dwg
.:�. ..�. .. =..:. �V ` :tea • • ; ..,�. !":" trill :. a.. e:... .
'4► •w7►•