HomeMy WebLinkAboutPermit D03-205 - GENE JUAREZ CORPORATION - TENANT IMPROVEMENTGENEJUAREZ CORPORATION �� JU UO N W =. 10828 EAST ALL. u MARGINAL WAY S u_< N. Z �. O Z �. U � O N; o �. D03 -205 W : Z W = 0 Z W F- I O F-' L Cit y of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 DEVELOPMENT PERMIT Parcel No.: 0323049164 Permit Number: D03 -205 Address: 10828 EAST MARGINAL WY S TUKW Issue Date: 08/05/2003 Suite No: Permit Expires On: 10/22/2004 Tenant: Name: GENE JUAREZ CORPORATION Address: 10828 EAST MARGINAL WY S, TUKWILA, WA Owner: Name: E MARGINAL WAY PROPS LLC Address: 3006 NORTHUP WAY STE 101, BELLEVUE WA Contact Person: Name: DAVID KEHLE Address: 12720 GATEWAY DR, SUITE 116, TUKWILA, WA Contractor: Name: M M I SERVICES INC Address: 245 S SUNSET WAY, ISSAQUAH WA Contractor License No: MMISEI *094P5 DESCRIPTION OF WORK: REMOVE NON - BEARING, NON -RATED DEMISING WALL, AND REMOVE NON - BEARING STORAGE ROOM; INSTALL NEW NON- BEARING OFFICE WALLS; ENCLOSE EXISTING 900 SF CABINET SHOP TO ROOF DECK Value of Construction: $23,000.00 Fees Collected: $603.86 Type of Fire Protection: SPRINKLERS Uniform Building Code Edition: 1997 Type of Construction: VN Occupancy per UBC: 0016 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: N Moving Oversize Load: N Start Time: End Time: Sanitary Side Sewer: N Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Profit: N Non - Profit: N Water Main Extension: N Private: N Public: N N Water Meter: doe: Devperm ** Continued Next Page ** D03 -205 Phone: Phone: 206 433 -8997 Phone: 425 369 -8655 Expiration Date:03 /04/2006 Printed: 06 -14 -2004 ia:n Print Name: doc: Devperm City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit. Signature: ��/ Date: - I e Date: // - Dy This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D03 -205 Printed: 06 -14 -2004 Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0323049164 Address: 10828 EAST MARGINAL WY S TUKW Suite No: GENE JUAREZ CORPORATION 10828 EAST MARGINAL WY S, TUKWILA, WA E MARGINAL WAY PROPS LLC 3006 NORTHUP WAY STE 101, BELLEVUE WA DAVID KEHLE Address: 12720 GATEWAY DR, SUITE 116, TUKWILA, WA Contractor: Name: M M I SERVICES INC Address: 245 S SUNSET WAY, ISSAQUAH WA Contractor License No: MMISEI*094P5 DESCRIPTION OF WORK: REMOVE NON - BEARING, NON -RATED DEMISING WALL, AND REMOVE NON - BEARING STORAGE ROOM; INSTALL NEW NON- BEARING OFFICE WALLS; ENCLOSE EXISTING 900 SF CABINET SHOP TO ROOF DECK Value of Construction: Type of Fire Protection: Type of Construction: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: doc: Devperm $ $23,000.00 SPRINKLERS VN Public Works Activities: N N N N N N N N N N N N DEVELOPMENT PERMIT Number: 0 Start Time: Volumes: Cut Start Time: Private: N Profit: N Private: N D03 -205 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 433 -8997 Phone: 425 369 -8655 Expiration Date:03 /04/2004 Fees Collected: $603.86 Uniform Building Code Edition: 1997 Occupancy per UBC: 0016 Size (Inches): 0 End Time: 0 c.y. Fill 0 c.y. End Time: Public: N Non - Profit: N Public: N D03 -205 08/05/2003 02/01/2004 Printed: 08 -05 -2003 Print Name: doc: Devperm City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Permit Center Authorized Signature: - /i0/ a.}1 - - `e I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit. Ale 3 Signature: Date: McG7hAa This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D03 -205 Date: C)f h 3 (c 3 Printed: 08 -05 -2003 4.1tE?RiuTt -p7 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0323049164 Permit Number: D03 -205 Address: 10828 EAST MARGINAL WY S TUKW Status: ISSUED Suite No: Applied Date: 07/10/2003 Tenant: GENE JUAREZ CORPORATION Issue Date: 08/05/2003 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 4: All mechanical work shall be under separate permit issued by the City of Tukwila. 5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 6: Any new ceiling grid and Tight fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 7: Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 8: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 9: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 12: ** *FIRE EXTINGUISHERS * ** - UFC Article 10 and NFPA 10. 13: The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or Tess. (NFPA 10, 3 -1.1) 14: Maintain fire extinguisher coverage throughout. doc: Conditions PERMIT CONDITIONS 15: Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) 16: Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207 -1212) 17: When two or more exits from a story are required, exit signs shall be installed at the required exits and where D03 -205 Printed: 06 -14 -2004 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 otherwise necessary to clearly indicate the direction of egress. (UBC 1003.2.8.2) 18: Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1) 19: All exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 1 1/2 hours in case of primary power Toss, the exit signs shall also be connected to an emergency electrical system provided from storage batteries, unit equipment or an on site generator set, and the system shall be installed in accordance with the electrical code. (UBC 1003.2.8.5) 20: Maintian sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. 21: Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13- 4- 5.5.3.1) 22: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recorgnized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1901) 23: All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 24: Contact the Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1900 and #1901) 25: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 26: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Conditions * *continued on next page ** D03 -205 Printed: 06 -14 -2004 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any regulating construction or the performance of work. Print Name: � l�h Z. ft" doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 D03 -205 of law and ordinances other work or local laws Signature: � l Date: 4 ray O Printed: 06 -14 -2004 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS z 1 z '~ W J UO J = H W W¢ = • a W Z = F— O Z F— W • W U� O N CI F— W • W F— H • O w z O — F- O /— 9: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be z construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. Parcel No.: 0323049164 Permit Number: D03 -205 Address: 10828 EAST MARGINAL WY S TUKW Status: ISSUED Suite No: Applied Date: 07/10/2003 Tenant: GENE JUAREZ CORPORATION Issue Date: 08/05/2003 1: ***BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 4: All mechanical work shall be under separate permit issued by the City of Tukwila. 5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 6: Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 7: Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 8: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 12: ** *FIRE EXTINGUISHERS * ** - UFC Article 10 and NFPA 10. 13: The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or Tess. (NFPA 10, 3 -1.1) 14: Maintain fire extinguisher coverage throughout. 15: Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) 16: Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207 -1212) 17: When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate the direction of egress. (UBC 1003.2.8.2) doc: Conditions D03 -205 Printed: 08 -05 -2003 ''IOW% 18: Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1) 19: All exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 1 1/2 hours in case of primary power loss, the exit signs shall also be connected to an emergency electrical system provided from storage batteries, unit equipment or an on site generator set, and the system shall be installed in accordance with the electrical code. (UBC 1003.2.8.5) 20: Maintian sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. 21: Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13 -4- 5.5.3.1) 22: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recorgnized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1901) 23: All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 24: Contact the Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1900 and #1901) 25: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 26: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: � �^-� Date: 875763 Print Name: doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 D03 -205 Printed: 08 -05 -2003 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Site Address: Tenant Name: ave Property Owners Name: H Y CAL co. [tic. Mailing Address: CCU /keellowe to% Stiffs IoI Name: tzoo II X LE c 11 Mailing Address: L2i1,ic £ Pi. Sift' l a ONTACT PERSON • E -Mail Address: GENERAL CONTRACTOR INFORMATI Company Name: RH Mailing Address: 1.44 Contact Person: eautil E -Mail Address: t, G1p Company Name: 3it 10614106 / IVOR Mailing Address: 1 7A7 E 1./i. 1 V(g Contact Person: 12\110 16E41,6 ;ENGINEER OF- RECORD All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Contact Person: E -Mail Address: \applications\permit application (3-2003) 3/2003 µ�k Page 1 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Cit King Co Assessor's Tax No.: Suite Number: New Tenant: ❑ .... Yes h13. State , .. Zip Day Telephone: ' T • 4-3:3-b41 Wb . cOneor City State Zip Fax Number: 'O- ttlik4M1 tg..No State Zip Day Telephone: •• %4 Sta: City Fax Number: E -Mail Address: Contractor Registration Number: i.e.. L 1* 0 f y Expiration Date: e$31 * *An original or notarized copy of current Washington State Contractor License must be presented at the time of pennit issuance ** .,::ARCHITECT OF RECORD. .= All: plans must be wet stamped by Arcliitect. Record * w . agloc City State Zip Day Telephone: tag • Pj Fax Number: o.'t4 Q- F57{061 State Zip City Day Telephone: Fax Number: DING PERMIT•INFORM4, ION 206 431 -3670 Valuation of Project (contractor's bid price): $ C. Existing Building Valuation: $ Scope of Work (please provide detailed information): VC�' ast. I1O - Mitii..kt 1 ti' 149 l / E. frfAtig • b r... L. Will there be new rack storage? 0 ..Yes N.. No If "yes ", see Handout No. for requirements. Ztsic " 2 Pii4" All Building Areas in Square Footage Below rt �t�J�IG�Pe' 1' ; 2 Floor 3f Floor: • Floors: • • :thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport • Detached Carport •Covered Deck Uncovered. Deck. Interior Remodel Addition to Existing. Structure. Type of Construction per, UBC . Type of Occupancy per UBC. h1 i t 1 0P PLANNING DIVISION: Single- family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? [] ....Yes /gt..No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: y gl.. Sprinklers Ei ..Automatic Fire Alarm 0..None 0.Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes .No If "yes", attach list of materials and storage locations on a separate 8-1/2 x 11 paper indicating quantities and Material afety Data Sheets. lapplications \permit application (3.2003) 3/2003 Page 2 Water District ❑ ...Tukwila ❑... Water District #125 ❑ ...Water Availability Provided Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) �ORKSPER .MIT�INT"��t.MATION:'�' 1-i i f1 t11 i Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ..:Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water \applicationslpennit application (3 -2003) 3/2003 ❑ ,. Abandon Septic Tank ❑ ,. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line „ „ ❑ ...Permanent Water Meter Size... 12 WO# ❑ ...Temporary Water Meter Size.. 1 1 WO# ❑ ...Water Only Meter Size WO# ❑ .,.Sewer Main Extension Public Private ❑ ...Water Main Extension Public Private Page 3 06=:433 =01 Scope of Work (please provide detailed information): Call before you Dig: 1- 800 - 424 -5555 Please refer to Public Works Bulletin #1 for fees and estimate sheet. ❑ .. Highline ❑ ...Renton Sewer District ❑ ...Tukwila ❑ .,. ValVue ❑ .. Renton ❑ ...Seattle ❑ ..,Sewer Use Certificate 0... Sewer Availability Provided ❑ .. Approved Septic Plans Provided ❑ ...Septic System - For onsite septic system, provide 2 copies of a current septic design approval by King County Health Department. ❑ ., Geotechnical Report ❑...Traffic Impact Analysis ❑ .. Maintenance Agreement(s) 0... Hold Harmless ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance 0 .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ,..Deduct Water Meter Size " FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ... Sewer ❑ ... Sewage Treatment Monthly Service Billing to: Name: Mailing Address: City State Zip Day Telephone: Water Meter Refund /Billing: Name: Mailing Address: State Zip Day Telephone: City Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >= 10,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU Furnace>I00K BTU Evaporator Cooler 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan 15 -30 HP /1,000,000 BTU Suspended /Wall /Floor Mounted Heater Ventilation System 30 -50 HP /1,750,000 BTU Appliance Vent Hood 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System Incinerator - Domestic Air Handling Unit <= 10,000 CFM Incinerator — Comm /Ind MECHANICAL PERMIT INFORMATION `= 206 -367 • • MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Use: Residential: New .... Replacement ....D Commercial: New ....0 Replacement .... Fuel Type: Electric 0 Gas ....0 Other: Indicate type of mechanical work being installed and the quantity below: ;PERMIT. APPLICATION NOTES - Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW TI-IE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING it grolATHORIZED AGENT: Signature: Print Name: libvi Mailing Address: / ZO \applications \permit application (3- 2003) 3/2003 eR2 Page 4 Day Telephone:- 433 - E City State Date: 0 1110 1,03 State Date Application Accepted: 2 /o -3 Date Application Expires: — D1 1 Staff Initials: 1 Zip Zip N '!. .1'+; "Ya',fSf ;tY^.Q:ww';54iY'.i Parcel No.: Address: Suite No: Applicant: Receipt No.: Initials: User ID: Payee: doc: Receipt City of Tukwila TRANSACTION LIST: Type Method 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 0323049164 10828 EAST MARGINAL WY S TUKW GENE 7UAREZ CORPORATION R03 -00822 SKS 1165 DAVID E. KEHLE ARCHITECTS Payment Check Description 15637 RECEIPT ACCOUNT ITEM LIST: Description Account Code PLAN CHECK - NONRES 000/345.830 Permit Number: Status: Applied Date: Issue Date: Payment Amount: 236.11 Payment Date: 07/10/2003 02:16 PM Balance: $367.75 Amount 236.11 Current Pmts 236.11 Total: 236.11 D03 -205 PENDING 07/10/2003 07;9 07t'':1 9716 TOTAL :236 . 1,i Printed: 07 -10 -2003 Z H • W; J U O 0 W I W O. Receipt No.: R03 -00957 Payment Amount: 367.75 g a c Initials: LAW Payment Date: 08/05/2003 12:13 PM = 0 User ID: 1630 Balance: $0.00 W Z� I- 0 Z I- W uj Do O N' TRANSACTION LIST: W W Type Method Description Amount H U LL O Payment Check 5576 367.75 Z W — I 0 Z Parcel No.: 0323049164 Permit Number: D03 -205 Address: 10828 EAST MARGINAL WY S TUKW Status: APPROVED Suite No: Applied Date: 07/10/2003 Applicant: GENE JUAREZ CORPORATION Issue Date: Payee: MMI SERVICES INC ACCOUNT ITEM LIST: doc: Receipt City of Tukwila Description 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 BUILDING - NONRES 000/322.100 STATE BUILDING SURCHARGE 000/386.904 RECEIPT Account Code Current Pmts 363.25 4.50 Total: 367.75 .i2:;i OB/06 9716 TOTAL 7367.75 Printed: 08 -05 -2003 COMMENTS: Type of Inspec n 0 .... ) 7'91,5> -7I /r t7 sS) S - /C.-14 1),G0/7 Z.'" 1?ee1Pit..}� %r' / mil" / fr/✓ ..C4+ Afar A / / (9 riI G ,2 / 7.../14 5 /-Avet l am'. D e Wanted: a.m. ) f (p.m 1 &.")'1--I 4-1.0. Phone N : � 5 - 7 i'5 - 910‘e(e I i y t ' Pro' t: Type of Inspec n A re s:,.. J 0 ( C / , n14.r5. L,' Date Called: ,5, I I f (r)-3 -- Special Instructions: l am'. D e Wanted: a.m. ) f (p.m 1 Requester: �t" P Phone N : � 5 - 7 i'5 - 910‘e(e .':'iinJx {ti:,: i.''v�- jh4�.'a:k'::`.v L'�vrri.'i:s, .:. is4 ''is�'it^7,:.::.•.•,.i:i...�;:, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. I spe INSPECTION NO. Rec 10 No.: INSPECTION RECORD Retain a copy with permit Date: .0 D-37;05 PER • ( 06)431 -3670 Corrections required prior to approval. Date: 1 4 ` / / fp- -4? 3 .00 REINSPECTiON FEE REQUIRE . Prior to inspection, fee must be 4(d at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Project: (i J Q a Type of In pection: ( r, � i( . I, U 7 i I (1./4C 1 dc � a � . 1(1k -./ Dat C . 1 - 7/v 3 Special Instructions: 'Date Wanted: 1 aieV / j „: p.m. Requester: / k- 5 ta -e'LI 3.r�..t Phone No: 1 °5iS i 8OR INSPECTfaN NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 1)03 El $47.00 REINSPECTI FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Approved per applicable codes. Corrections required prior to approval. COMMENTS: D ate Receipt No.: Date: P eject:' Type f Inspection: • Address' - 70 ,',2erf e7—filla; W ..5.- Date Called: w)i.e.:77703 Special Instructions: Date Wanted: ;1 a, Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 MENTS: Approved per applicable codes. ❑ Corrections required prior to approval. $47.00 REINSPE N FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 4 Project: Type of Inspection: Address: 108,1F3 2 , O n AQ61 IJi L - Date Called: +& S i ( — I L /-- t r=�- Special Instructions: Date Wanted: u —,4- 03 m, i Requester: Awl Phone No:� c, Li 2 5 / 7 [=� -.96°66 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. $47.00 REINSPECTION FEE REARED. Prior to inspection, fee must be paid at 300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt.No.: Date: COMMENTS: b)/, /67 f •=> /" C vet // . / 3 > 6e, . 7/9 1 Y! ' / gee"' l 1 e a w QQ • � JU U O CO W= J � w 00 g J u_ ? u d = W F- Z�. Z UJ w U� w 0I- WW 0 .= • Z W U = 0 2 Pr,o.�►�ct: Type of Inspection: Address � Date Called: n / Special Instructions: S ti y s r� A e4 � Date Wanted: C.a.m. Requester t . � Ph one / ___:\ 1 IA? 5 _ 3a - / O 1- INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMI CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 a pproved per applicable codes. Do 3 -ac Corrections required prior to approval. COMMENTS: C/7) 6 -f°,'r / Date: .00 REINSPECTION F:E REQUIRED. Prior 10 inspection, fee must be aid at 6300 Southcente Blvd., Suite 100. Cal to schedule reinspection. Receipt No.: Date: Prom 1 (1 --) l'faite3 Type ofjaspection: . Address: iDfrUg E . Illery Date Called: WE r Van'ted• 010? Special Ins/ructions: / I S ( 1 1 1 U Requ er: • a Mel ( Phcalello:\ VO -" tiO 7")( , r 10,7,^t , - . . . . . „ • t. E2 Approved per applicable codes. INSPECTION NO. INSPECTION RECORD Retain a copy with permit • CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 .1■••••••••• COMMENTS: ,„. Ins ctor: ) CA.A.kk 47.00 REINSPECT ON FEE REQUIR aid at 6300 Southcenter Blvd., Suit ipt No.: Date: ) — D. Prior to inspection, fee must be 100. Call to schedule reinspection. Date: El Corrections required prior to approval. 'RO5 y - . • Sprinklers: • Fire Alarm: • Hood & Duct: Halon: • Monitor: Pre-Fire: Permits: Authorized Signature FINALAPP.FRM t City of Tukwila Fire Department (). Rev. 2/19/98 7;0,7;4'117:417 7. 41 " Trno ' '1;4". '4 A r • 144.7,Z(77 ; 7717:: r „ TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name A • Address • e • :cur i.4.nspect±o schedule . Needs shift inspection \/. Approved without correction notice • Approved with correction notice issued , Steven M. Mullet, Mayor Thomas P Keefe, Fire Chief Date _ Permit No. I Suite # T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575-4439 09 -07 -2004 DAVID KEHLE 12720 GATEWAY DR, SUITE 116 TUKWILA, WA 98168 RE: Permit Application No. D03 -205 10828 EAST MARGINAL WY S TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and /or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Permit Center at 206 -431 -3670 to arrange for the next final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one - tine extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 10/22/2004, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Stefania Spencer, Permit Technician xc: Permit File No. D03 -205 Bob Benedicto, Building Official City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Space Heat Type 0 Electric resistance 0 All other (see over for definitions) Glazing Area Calculation Note: Below grade walls may be included in the Gross Exterior Wall Area if they are insulated to the level required for opaque walls. Total Glazing Area Electronic version: these values are automatically taken from ENV -UA -1. (rough opening) Gross Exterior (vertical & overhd) divided by Wall Area times 100 equals % Glazing T X 1 00 Concrete/Masonry Option O yes Check here if using this option and if project meets all requirements for the ConcretelMasonry Option. See Decision Flowchart (over) for qualifications. Enter requirements for each aua tying,,,;.,.., O no assembly below. I r" t t r- r nDV Project Info Project Address 1 0' 1.l t ro ii J j _ i.. -=(' • Date eZ LLJ Q9 For Building r� *ase i , OF TUKWIIA J U L 1 0 2003 PERMIT CENTER Applicant Name: David Kehle Architect Applicant Address: 12720 Gateway Drive su 116 Applicant Phone: (206) 433 -8997 2001 Washington State Nonresidential Energy Code Compliance Forms Project Description Envelope Requirements (enter values as applicable) Fully heated/cooled space Minimum Insulation R- values Roofs Over Attic All Other Roofs Opaque Walls Below Grade Walls Floors Over Unconditioned Space Slabs -on -Grade Radiant Floors Opaque Doors Vertical Glazing Overhead Glazing Maximum U- factors Maximum SHGC (or SC) Vertical/Overhead Glazing Semi- heated space 2 Minimum Insulation R- values Roofs Over Semi - Heated Spaces 2001 Washington State Nonresidential Energy Code Compliance Form Envelope Summary Climate Zone 1, ENV -SUM ❑ New Building ❑ Addition Compliance Option ❑ Prescriptive ❑ Component Performance (See Decision Flowchart (over) for qualifications) ❑ ENVSTD 2.1 ❑ Systems (4.0 not acceptable) Analysis 1. Assemblies with metal framing must comply with overall U- factors 2. Refer to Section 1310 for qualifications and requirements Notes: No hitv Walt* O Alteration ❑ Change of Use Opaque Concrete/Masonry . Wall Requirements Insulation on interior - maximum U- factor is 0.19 Insulation on exterior or integral - maximum U- factor is 0.25 If project qualifies for Concrete /Masonry Option, list walls with HC ? 9.0 Btu/ft °F below (other walls must meet Opaque Wail requirements). Use descriptions and values from Table 20-5b in the Code. Wall Description (Including insulation R -value & position) U- factor caIY OF WOO :t:kzo5! b First Edition, June 2001 Project Info Project Address [(2b2.45 p , /t �� 1 t t f Y.Q L{DL- Date./ 1 1^ Watts/ Fixture athE ��P Covered Parking (standard paint) For Building DDeliltirIl e OI V OF TU WIl.A JUL 1 0 2003 PERMIT CENTER y Applicant Name: David Kehle Architect Applicant Address: 12720 Gateway Drive Su 116 Applicant Phone: (306) 433 -8997 Open Parking Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Covered Parking (standard paint) Gm t* T1 0.2 W /ft Covered Parking (reflective paint) 0.3 W/ft Open Parking � !!tt v L 1 Zu03 0.2 W /ft Alteration Exceptions (check appropriate box) . changes are being made to the lighting • Less than 60% of the factures are new, and installed lighting wattage is not b9inQjperpagpd Location (floor /room no.) _ 11 Occupancy Description , Pa Y o ` �t t � W atts per � � " ?r;k �'� A ra in f C A rea � agnrovals are Allowed x Area Covered Parking (standard paint) Gm t* T1 0.2 W /ft Covered Parking (reflective paint) 0.3 W/ft Open Parking � !!tt v L 1 Zu03 0.2 W /ft " From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts ) V Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Covered Parking (standard paint) Gm t* T1 0.2 W /ft Covered Parking (reflective paint) 0.3 W/ft Open Parking � !!tt v L 1 Zu03 0.2 W /ft Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts ) V Location Description Allowed Watts per ft or per If Area in ft (or If for perimeter) Allowed Watts x ft2 (or x If) Covered Parking (standard paint) Gm t* T1 0.2 W /ft Covered Parking (reflective paint) 0.3 W/ft Open Parking � !!tt v L 1 Zu03 0.2 W /ft Outdoor Areas ) V 0.2 W /ft Bldg. (by facade) 0.25 W /ft Bldg. (by Perim) 7.5 W /If Note: for building exterior, choose either the facade area or the perimeter method, but not both) Total Allowed Watts Lighting Summary LTG -SUM 2001 Washington State Nonresidential Energy Code Compliance Forms Project Description ❑ New Building ❑ Addition • Alteration El Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 2001 Washington State Nonresidential Energy Code Compliance Form Maximum Allowed Lighting Wattage (Interior 0 Prescriptive Q Lighting Power Allowance Q Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) FILE C June 2001 - KJM Notes: 1. Use manufacturer's listed maximum input wattage. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used 2. Include exit lights unless Tess than 5 watts per fixture. Proposed Lighting Wattage (Interib)st all fixtures. For exempt lighting, not exception and leave Watts/Fixture blank. Maximum Allowed Lighting Wattage (Exterior) wattage. hor textures wtth hara -wlrea oallasts only, Proposed Lighting Wattage (Exterior) the default table in the NREC Technical Reference Manual may also be used. May 18 04 03:58p p.1 MMi Services, Inc P. 0. Box 2768 Issaquah, WA 98027 425 369 -8655 May 18, 2004 z _ ,*"w . � e J 0 0 N W I J 1-, N u_ u 0 u.¢ z a 1 ._W m. z 1-. 1- a z 1-. Gordon Moorman ^>'� = 0 �� 1•- v, President q 1 - ~ ,� tii z . A CCp_ C � � O U = o o City of Tukwila 6300 Southcenter BL, Suite 100 Tukwila, WA 98188 Attn: Stephania Spencer Re: Gene Juarez Permit # D03 -205 Dear Stephania: Please extend the duration of the above permit due to delays in the project. Thank you 5/Zvp 4.qr/444 180c= 1 ` . '& Lic. # MMISEI *094P5 z April 6, 2004 David Kehle 12720 Gateway Drive, Ste 116 Tukwila, WA 98168 RE: Permit Application No. D03 -205 10828 East Marginal Way South Dear Permit Holder: Cii of Tukwila Department of Community Development Steve Lancaster, Director In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: • CaII the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to May 22, 2004, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Stefania Spencer Permit Technician Xc: Permit File No. D03 -205 Bob Benedicto, Building Official Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite /1100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: D03 -205 DATE: 07 -11 -03 PROJECT NAME: GENE JUAREZ CORPORATION SITE ADDRESS: 10828 EAST MARGINAL WY S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued Aw G ,� A'U�� . j 16,1-0-05 Buildin' g bivision [� Fire revention Public W � /1D3 Structural ❑ DEPARTMENTS: 1-15tS DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 07 -15 -03 Complete PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Incomplete ❑ apt_ itL 146 Planning Division kr Permit Coordinator Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS R�TING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 08 -12 -03 Approved ❑ Approved with Conditions [ Not Approved (attach comments) ❑ Notation: APPROVALS OR CORRECTIONS: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28.02 PERMIT COORD COPY ti liusi::.} :;:.�S:::il.=.'irlSti+j.�Y rxtCa Far..- ril s. y53:.ti4C L bYw.�' Gk.. u:« +'+:ti.irtid...XLLO.wi�2:t.:e:t+.: Jul 10 03 07:57a p.2 F625.052.000 (R197) JUL 10 2003 DAV1f) ? <EHLE \:?( i"FC DEPARTMENT OF LABOR AND INDUSTRII3S REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL REGIST. # .. EXP. DATE CC07:MMISEI *„p94P5 03/04/2004 EFFECTIVE'DATE "' 10/25/1991 M M I,SERVICES INC 245' S ' SUNSET WAY ISSAQUAH.WA 98027' k RECEIV CITY OF TUK WILA JUL 1 0 2003 PERMIT CENTER bO3 de •1 1 7' . • ,4T 1 • • • ��s �I, s I. • • • • • ., • "Wt • f • R ‘„ • • • • . y • Q „,. *L . . �rEo4- r _ G �, j. c_G • s f 0A Fir, • "b 1 • NORTH • .•■ w` Ifitocx • no Ma ‘6 . VICINITY MAP NOT TO SCALE � 6 ` ,r C • Jam .. PROPERTY TAX ACCOUNT NUMBER . 1 ‘6 032304- 9164 -09 1 .l't W P SITE PLAN o" • ` r • „1 S ��y � �R0P �S W �� • • . • • • • • • • BUILDING Sc SITE STATISTICS -SIZE AREA -LOT F= APPROXIMATELY 54,870 S.F. -LOT G= APPROXIMATELY 129,800 S.F. -TOTAL= APPROXIMATELY 184,670 S.F. - BUILDING AREA -TOTAL BUILDING= 89,340 S.F. TENANT SPACETHIS PERMIT -NO CHANGE OF USES EXISTING OFFICE= 674 S.F. EXISTING MANUFACTURING= 903 S.F. EXISTING WAREHOUSE= 13,923 S.F. TOTAL TENANT SPACE= 15,500 S.F. - PARKING PROVIDED = 121 -ZONING: MIC /4i4 -TYPE OF CONSTRUCTION: V -N -OCCUPANCY GROUPS: Si, F1, & B -BUILDING CODE: 1997 UBC • P I >741g �R 70 �O. ti o LEGAL TWAT PORTION OF TNI SOUTH /EST QUARTO OF SECTION 3, . TONNSIWIP $3 NORT1, RANGE 4 EAST, W.N., IN RING COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS: NOGINIIIIIS AT TRt INTERSBCM'IOU or THE EASTERLY MARGIN Or EAST MARGINAL WAY Mn'N, AND !'NS SCUTS LIME OF SAID SECTION 3: TNENCI MOWS SAID MANN= NOME 14'47 NEST 444.40 FEET TO TMR TRIUR POINT Or $EGIMIIWIIWGI 'rwENCI CONTINUING ALONG SAID MARGIN NORTH 14'47'30 UEST aoo.00 ram TxEI1CS WORTS 73'12°30 FIST TO Till WESTERLY BOUNDARY OF PUGS! SOUND POKIER AND LIGET RIGHT-O!' -NAT. rmaNE'RLT SEATTLE- TACOMA INTERURBAN RAILWAY RIGIFt -O /-MAT s TNENCZ SOLI NERLY ALONG SAID BOUNDARY TO A LINE MICR BEARS WORTS 73 EAST FROM TKO TWO POINT OF BEGINNING.: 'rxmi S 60WMI 73'12°30° NEST TO TR* TRUS POUR OF BEGINNING. • PARCEL G: EXCEPT TWAT PORTION DESCRIBED AS FOLLOWS: • By Dat Permit No. DESCR IPTIONS THAT PORTION or TNS sOUi71WCST QUARTER OF SECTION 3, TOWNSHIP 23 NORTH, RANGE 4 LAST, M.N., IN RING COUNTY, WASNINGTOWI, DESCRIBED AS FOLLOWS: BEGINNING AT TI1R INTERSECTION OF THE EASTERLY MARGIN OF EASE ,MARGINAL WAY, RAVING A RIGHT ANGLIA WID111 OF 40 FEET, W1TR TIM ROUTE LINE OF SAID SECTION 3, SAID POINT BEING 411.792 FEET, HOGS OR LESS, EASTERLY OF TMs SOUTHWEST CORNER OF SAID SECTION, THENCE SOOT, 89'47'20 EAST ALONG SAID SECTION LINE 324.788 FEET, MOOS OR LLZI, TO THS NEST SUA BOUNDARY LINE OF PUGET SOUND POWER AND LIGET COMPANY RIGHT -OF -MAY, FORMERLY SEATTLZ- TACOMA INTERURBAN MAMMY RIGHT-OT -MAY: THEMES FOLLOWING SAID WESTERLY BOUNDARY OW THE ARC OF A CURVE TO TER LEFT RAVING A RADIUS OF 2814.93 FEET AND TMR LONG CHORD OF MICR BEARS WORT M 18"15 WEST, 3S9.985 FEET TO A POINT OF TANGENCY: THENCZ OOmmorma ALONG SAID BOUNDARY POSTS 21'53°50° WEST 333.SO FEET TO A POINT OF A CURVE, •n[ i = ALONG SAID BOUNDARY 011 TIE ARC OF A CURVE TO TRR! RIGHT WEAVING A RADIUS OF 2914.93 FEET AND THE LONG CHORD OF wHICN BEARS NORTR 14'28'3:• %EST. AN AMC DISTANCE OF 400 PEST, MONK OR LESS, TO THZ ROUTE LINE or A TRACT DESCRIBED IN MODIFICATION OF CONTRACT RECORDED UNDER RECORDING NO. 19463441 SAID POINT ALSO BEING THE MORTIS LINE OF AN EXISTING PPIVATI ROADWAY: woe= ROUTE 79"12°30 NEST ALCI G SAID SOUTI1ERLY LINN 232 mum, HORN OR LESS, TO TIM SOUTHEASTERLY CORNER Or A TRACT CONDQOIED FOR MAD UNDER XING COUNTY SUPERIOR COURT CAM NO. 353823: L TWIN= MONTS 89'37'30° NEST AIMING TIR $OUTW LINE OF SAID TRACT 31.4 FEET TO A POINT ON TEE EASTERLY MARGIN OF EAST MARGINAL WATT THENCE SOiT:N 14'47'30• EAST 1420 FELT MORE OR LESS, ALONG ,SAID EASTERLY RARGIW To TUN PLACE OF BEGINNING: COIO4EMICIIIG AT A POINT OW TN! EASTERLY BOUNDARY LINE OP EAST MARGINAL MAT SAID POUT BEARS NORTE 14'47'30 %RS? 1387.1218 FEET FROM TWE POINT WWFTS TNS SAID EAST BOUNDARY LINZ INTERSECTS TIM SOtTIR BOI:NDART LINE Or SAID SECTION 3; RUNNING TNENCS •OUTS 14'47'30 EAST AUM G SAID EAST MAMIGIWAL LINE 192.529 FEET; TWICE CE SOUIR 89'37°30 EAST 2)2.103 FEET TO A POINT 70 FEE'? DISTANCE FROM THE CENTER LINE OF SEATTLE- TACOMA INTERURBAN RAILWAY; ' THENCE OW TNS MC OF A cum mimeo A RADIUS Or 2934.92 FEET ALONG THI WEST BOUNDARY LINE OF A CERTAIN LANE AND PARALLEL TO SAID CENTER LINE, Till LONG CHORD OF WHIM ARC BEARS PORTS 13'24'13 WEST 189.402 FEET; TIED= NOTE 89'37 NEST ALONG THIS SOUR BOUNDARY LINE or A CERTAIN PRIVATE ROAD 243.819 FEET TO T111 PLACE OF MIMING. 11 • i • ALSO , .. EXCEPT TWZRZMIO N TWA? PORTIOW THEREOF LYING SOUTHERLY OF TOR FOL.LOW/NG DESCMIBED LENSES: **GINNING AT TAR INTERSECTION OF TN! EASTERLY MARGIN OF EAST MARGINAL WAY SUITES AND T1 SOWN LAWS OF SAID SECTION 3, =ONCE ALONG SAID MANGIM NORTE 16'47•30• NEST 444.40 FEE? TO TH! TRUR POINT OF BEGINNING: Tfl lC! PORT! 73'12'30° EAST TO THI wZSTERL1 BOUNDARY OF TN! PUGILT SOUND POWER AND LIGHT RIGHT -OF -MAT, FORMERLY SEATlLZ- TALOMA INTERURBAN RAILWAY RIGHT-OF-NAY, AND THZ TERHINUI or SAID L.INZ. FILE COPY I understand that the Plan Check approvals are subject to errors and omissions and approval of plans does not authc-rite the violation of any adopted code or ordinance. Receipt of con- tractor's copy of approved plans acknowledged. SEPARATE PERMIT REQUIRED FOR: le MECHANICAL [ g ELECTRICAL LPLUMBING g„ GAS PIPING CITY OF TUKWILA BUILDING DIVISION R EVISIO I4 S virmrol giop APPROVAL OF lUICWILA BUISDiet! suo.014100,4 114E SCOPE OF WORK 1101110.0 WAX INCA016 A NIP/ PAP Aye Wm oroLuoi fitiAM NNW/ Via memo COY of TUcwiu► JUL 1 1 ap PERMIT COTES 1)03G- tf • .00. WA 4 OW At l<6 EXISTING DRIVE SNIPPING RECEIVING 1 STAGING 50' y REMOVE EXISTNG WALL WAREHOUSE Li xcuic Y GROUP si REMOVE EXISTING DEMISMG WALL 0 EX. Rfr a 9 REMOVE EX. DEMISING WALL 1 10 EX. :- x. RR REMOVE EXISTING 5II'MC 4 REPLACE W/ NEW STAINLESS STEEL 4 GOOSE NECK FAUCET EX. OPEN ONCE EXISTING PULL WEIGHT DEMISING WALL, NO CI4ANGE 1 TOR LOCK UP kJ xcu. GROUP 5t EX. FACTORY AREA [Pi OCCUPANCY GROUP = Fl 903 SF. NO OCCUPANCY SEPARATION PER NOTE 5 ON TABLE 3-B 1991 UBC w/ DUST COLLECTION SYSTEM BY TENANT • FILM. CUCKOO 24 TOP FLAW .4' GYP. eD. DOW Gar 2O • II' oc. l FULL NEIGFlT WALL DEAD DETAIL PARALLEL TO PURt.IN SCALE 1 v. • 6wGtr» PD11.411 0111e POW. =KM — .- !)dm 2X.t:_ - :NNE. Ralf. HEK IM.. 14E6D DETAIL FEWENDICULAR TO PURLN SCALE 1 la°•I' •fD" ATTACH BOTTOM PLATE TO Cc*IC. FLOOR UV POWER DRIVEN Ablai01Qs AT 24' OTC. 2 V2' RU38ER BASE • CARPET WALL DETAIL SCALE 1 V2'•I' -0" tcP cP ORACKEY 5/6' GYP. O. BON SIDES 2X4.24' OTC. WALL TYPE SCHEDULE in EXISTING CONCRETE WALL, NO CHANGE. co EXISTING PARTIAL HEIGHT STUD WALL, 2X4 0 16" O.0 INSTALL DIAGONAL 2X4 BRACES 0 4' -0" O.C. FROM TOP PLATE BACK ''08 ROOF STRUCTURE. INSTALL NEW STUD WALL ON TOP OF EXISTING WALT., 5/8" GYP. 9D. 90TH SIDES 2X4 0 16' O.C., DETAILS 1/T -1 & 2/T -I. ® EXISTING STUD WALL, NO CHANGE. w REMOVE EXISTING V/OOD CASING FROM HEAD & JAMBS FROM OPENING, MILL OPENING w/ 5/8' GYP. B0. BOTH SIDES 2X4 0 24' 0•C., FMASH SMOOTH & FLUSH, DETAIL 3/T -1. O] EXISTING PARTIAL HEIGHT STUD WALL,, 2X4 0 16' O.C. W/ 5/8" GYP. BD. ONE SIDE. REMOVE TOP PLATE, INSTALL NEVI FULL HEIGHT 2X6 STUDS TO UNDER SIDE OF ROOF STRUCTURE 016" O.0 ADJACENT TO EXISTING STUDS & INSTALL 5/8' GYP. B0. BOTH SIDES FULL HEIGHT, FIRE TAPE, DETAILS 1/T -1 & 2/T -1. DOOR SCHEDULE DOOR E I : EXISTING 311 STOREFRONT DOOR DOOR E 2 : COSTING 3'X7' INTERIOR WOOD DOOR DOOR E 3 : EXISTING 3'X7' INTERIOR WOOD DOOR W/ PRIVACY LOCK DOOR E 4 : EXISTING OVERHEAD DOOR DOOR E s : EXISTING 3'X7' EXISTING HOLLOW METAL DOOR DOUR E 6 : EXISTING PAIR 3'X7' INTERIOR WOOD DOORS W/ METAL JAMB, L.ATCHSET, FLUSH BOLT, 2 WAIL. STOPS, ASTRAGAL 3 PAIR BUTTS, 2 SILENCERS DOOR 1 : 3'X 7' SOLID CORE WOOD DOOR W/ WOOD JAMB, LOCKSET, 1 1/2 PAIR BUTTS, WALL STOP, 3 S1LENCERS. EXISTING GYP. BD. CEILING CEILINGS, NO CND EXISTING SUSPENDED ACOUSTICAL CEILING • 9I -9" AFF. (TYP.), NO CHANGE LEGEND MX: IC Ili MOM ill. 011111111, et' l' 4' a' k REFLECTED CEILING PL4N RELECTED SCALE: va • 1 EXISTING WALL NEW STEEL SW WALL EXISTING WALL TO BE REMOvED. NEW DOOR EXISTING DOOR 6CALE 1/8" • 1'40 � A JUL 1 0 2113 PERMIT CENTER PD2-o S 16 24' 32' 40' V . 07/08/2003 10:03 ari C: \CAD \0238— McCONKEY \T -1.dwg .:�. ..�. .. =..:. �V ` :tea • • ; ..,�. !":" trill :. a.. e:... . '4► •w7►•