HomeMy WebLinkAboutPermit B92-0012 - BEST PRODUCTS - OFFICEb92-0012 best products interior demo 17500 southcenter parkway SST WONACTS TYPE OF CONST.: UBC EDIT ION (year) 1988 SETBACKS: N — S — E— W- FIRE PROTECTION: QSprinkiers 0 Detectors 0 N/A UTILITY PERMITS REQUIRED? DY es BAR /LAND USE CONDITIONS? ( public r VJorksL (2 No 4 N 0 Yes ZONING: CONDITIONS (other than those noted on or attached to permit/plans) CITY OF TUKWILA Dept. of Community Development- Building Division 6300 Southconter Boulevard, Tukwila WA 98188 (206) 431 -3670 BqQ oo 1 Q 15 :00 ' �`;` t �' �':'�L•i }. ,;f•;., , a . DATE PLAN CHECK NO.: TOTAL- 29.25 B92 -0012 BUILDING PERMIT NO. DATE ISSUED: SITE ADDRESS 17500 Southcenter Py SUITE f I VALUE OF CONSTRUCTION - $ 400.00 PROJECT NAME/TENANT j ASSESSOR ACCOUNT # Best Products l 262304- 9110 -07 TYPE OF New Building J_ Addition (x] Tenant Improvement (commercial) U Demolition (building) U Grading/Fill WORK: 0 Rack Storage [1 Reroot 0 Remodel (residential) 0 Other: DESCRIBE WORK TO BE DONE: REmove part of existing office. PROPERTY OWNER ADDRESS CONTRACTOR ADDRESS WA. ST. CONTRACTOR'S LICENSE ARCHITECT ADDRESS MPLIANC FLOOR TOTAL OCC. LOAD SQUARE FEET OCC. SQUARE OCC. LOAD FEET LOAD SQUARE FEET O::C. LOAD SQUARE FEET OCC. LOAD TOTAL SQUARE FEET TOTAL OCC. LOAD USE APPROVED FOR ISSUANCE BY: SIGNATURE: CERTIFICATE OF OCCUPANCY NO. Trammell Crow 17900 Southcenter Parkway, Tukwila, WA Owner PRINT NAME: 1---A, M I S BULDE1G PERMIT (POST WITH INSPECTION CARD AND PLANS IN A CONSPICUOUS LOCATION) DESCRIPTION BUILDING PERMIT FEE. PLAN CHECK FEE BUILDING.SURCHARGE: OTHER :: BUILDING OFFICIAL DATE: COMPANY: DATE ISSUED: PHONE PHONE EXP. DATE PHONE ZIP ZIP 98188 ZIP DATE: 0-76 I hereby certify that I have read ,and examined this permit and know the same to be true and correct. All provisions of lay and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume • give authority to violate or cancel the provisions of any other state or local laws regulating construction or the /perfor nce :of work. I am authorized to sign for and obtain this building permit. SAi„s z� tell 2-- This, permit shall be null and void:if the works not commenced within 180 days from the.date of< issuance, or if the :work is. suspended or abandoned for a period of �'.180`days from the last; inspection PERMIT NO. CONTACTED r DATE NOTIFIED J .'' 1 / BY: i nit. •1,13 DATE READY PERMIT EXPIRES 2nd NOTIFICATION BY: (init.) AMOUNT OWING G `"I t J 3RD NOTIFICATION BY: (init.) ( BUILDING S PERMIT APPLICATION TRACKING PLAN CHECK NUMBER y PROJECT NAME SITE ADDRESS INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". BUILDING SQUARE FOOTAGE/OCCUPANCY INFORMATION (to be filled out by Plan Checker) FL( SQUARE OCC. FEET LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD TOTAL SQUARE FEET DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. J BUILDING - initial review (FIRE O PLANNING O PUBLIC WORKS O OTHER BUILDING - final review 111-ct 1 15 RO FIRE PROTECTION: FIRE DEPT. LETTER DATED: UTILITY PERMITS REQUIRED? Yes PUBLIC WORKS LETTER DATED: - TYPE OF CONSTRUCTION: Twcte. tw it k) S•rinklers ■ Detectors -� INSPECTOR: UBC EDITION (year): REVIEW COMPLETED INIT: N 1A INIT: ,V/'4 INIT: INIT: TED ?rxc± ................ ............................... CONSULTANT: Date Sent - Date Approved - MINIMUM SETBACKS: N- S- TOTAL OCC. LOAD ZONING: mBAR/LAND USE CONDITIONS? ( )Yes (l No REFERENCE FILE NOS.: OB/17l9 SITE ADDRESS / SUITE # v s' 0 0 4a U0 - r 14t. tr -i- - \ '�-- S'h14- VYA-4A 1 u r. ilk 1 k-Ik /A ih I b t - ' VALUE OF CONSTRUCTION - $ ,�}i_Or1� -- v PROJECT NAM - NAN _,) FA-' t- rI T ed f ASSESSOR ACCOUNT # CO7304 - 11(0.—(0` TYPE OF O New Building • Addition P Tenant Improvement (commercial) U Demolition (building) WORK: 0 Rack Storage 0 Reroof Remodel (residential) 0 Other: DESCRIBE WORK TO BE DONE: , (2.. i -1 ,94 v _ t'' --1- 0 4=- tr -1(i ? - Pa iO ( =)- i r,t .- BUILDING USE (office, warehouse, etc.) • (0 Vr -t 6- r— NATURE OF BUSINESS: g t`- t-y{... WILL THERE BE A CHANGE IN USE? A No 0 Yes If Yes, new building requirements may need to be met. Please explain: SQUARE FOOTAGE - Building: l,'7 ct' i 0 0 Tenant Space: 1 70 c, O o Area of Construction: 6'3 WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? 1$ No 0 Yes IF YES, EXPLAIN: PROPERTY OWNER . / M ELL- z PHONE ADDRESS 01 0 0 (� T.' v1 ;,rte - kA ei Si V.i ZIP CONTRACTOR W �.� y '( NU PHONE ADDRESS ZIP WA. ST. CONTRACTOR'S LICENSE # EXP. DATE ARCHITECT PHONE ADDRESS IZIP BUILDIF' PERMIT APPLICATION CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 DESCRIPTION BUILDING PERMIT: FEE PLAN CHECK:: FEE `::<<:!:;` DATE APPLICATION ACCEPTED BUILDING 'SURCHARGE' : EREBY CERTIFY THAT i : HAVER D AND:; TRUE AND `CORRECT, AND: I , AM AUTHOR! BUILDING OWNER SIGNATURE � 'I�� 71T OR PRINT NAME PHONE AUTHORIZED k_M f, � D'F ��t S 6-7 ' 2 5 AGENT ADDRESS l -/ 0,_ R- p,KkAi CITYZlP.. � k�GV�l:/k /6(� CONTACT PERSON �� rm c APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT if the applicant is other than the owner, registered architect/engineer, orcontractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431 -3670. DATE APPLICATION EXPIRES ` 1 - qQ COMMERCIAL • -••• • . •• , • ••,..• • • ••• • • s • • . •:•..:.•.•...: • --. • :'••• NEW COMMERCIAL • BUILDINGS/ADDITIONS • • . • • .•••• L. ••••:: 'L " Completed building•PermIt.applicatiOn (One;for: :,•:::::"•:::::••• AsicissOr:ACcOunt ..ss,.. • ••• Specifications •••• Ti Structural calculations stamped by a Washington State licensed engineer stamped oshtgton,I•PtateliCena':d • .• • •:•...• . • • • .„,. ' t EnergY,O0.1601atiOnd.itd • pograph i cal survey Y a Washington State l icensed ' .engineer or architect " • • . Legal description.:.. : : •' • • •••• • „: Working drawingi, stamped by a Washington State licensed . architect, which include: ;Completed utility.' parMitiappliCation.(one.':for ,;::::: Six (6) sets of civil drawings NOTE See utility permit applicaiion and eheckhst for specific utility • : ••• submittal requirements.: • . •••:"•:•:• •• ••••• ••••••••• •••• • • •• •• •-•-• • .:: : ; „ ; ; • • bUiIdincj permit : application [] Asossor Account Number Two --..•••• • • ...• • Building floor plan showing Entire space whore racks will be located ..„ Tenant space floor : planishOWingirack • exits NOTE Include dimensions of racks (height, width and length) aisles • • •:•• •• and .exit. ways on r- • ' .• •:StiPPtural . engineer (rack storage 8 and over) RESIDENTIAL .• .: •:.• •-........: .....:',•::: .... • ..................:„..•;••••• • •............"...:::•:.• • ........„,„'„:•:-. „ . ., . . .. ..........., '• . :•":" . . 1 ':•' . ..'"'.•" 1 - .......... • .••• • ..........••••„: • : .:•••••...:.,......:...............:-:.,.......:::::::•.•,:„. . ' • ......:::"............•••......••••.•.:••: f---1..Corripleteci building *permit applicatiOnionafor:each ... ... ...... ... ... . .. , . .... ' •.:, . :.•••::::::::::::',...]::•:::::•"....:'::':::::::::•:,..;•'...:::::::::•::::::::::.!-::-!.:'::::::::•:...::::::::"..:::.:".•::::::::::!:::: 1 ..LOgal.•description:•:" . :::',.::::::::„.....,: : :::" ... .„:,•„ , ..:• . :;.....::::.....:...:.":".....::::: - .......„ . . : : : ::::::':"....,•::::::::::::".•: . ::::::::: . 4 : ::::::::: : : :::::::;•:•••••4:::: : ::::: : :::::::::::::•:::::::::. „ ..• SUBMITTAL CHECKLIST ••• COMMERCIAL TENANT IMPROVEMENTS • . . . : • • . . . ; . Completed building permit aPplicatIon tenant) AssassorAccount OppitruCtion:Pland,';WhiCh, : ..:.„ •• • :::: :.:•: • : ; • .. : 1 I , ......... . .. ... ...; • . : : : : . : • : : • '.:": • • • '.'•••'•••:•••••• • Location of tenant space • Existing and proposed parking • Landscape plan (if applicable i e , change of use Overall building plan Use of :$.14 adjacent . .(aCiMriiori . :Witli) : fe . riOn • .. •"" •• • showing:#4 .Construction • • • u . . • • Cross . ::sectIons.: construction and.pleth0r4 of atur • truCtur,: • ! Cb MPP t.for . ceilin . don '11■10TE ....... . . sepg tamP al•wo rtyper.itt d itstru . . bY a e • Tenant space plan with OSii-of each • 'Exit doors,. egress patterns.•': •.:::•. • • New walls, existing wall, and walls to be demolished •: •••• • • ••• •••: ••••: • - • • •• .••• • . . • . Completed b uilding •porrrilti Assessor Account Number .. . . •:. : material being installed '..NOTE .requIra p Inspa off of the permit ................................................................... .......................... . ........................................... '' s ............................................. application Details ............................................................................................................................................................................................................ ............................ location ................................. . ........................................................... antenna/satellite .............................................................................................................................. • • incIY°".....„:•••••••••••••••••••, ••••• • an dM : • : •• • Structural • ca lculations Led ro ec : Type of Inspection i Address: i 9,0 LS .?r Date Called: 1 / —z3 -P Z Special Instructions: 70:a5 Date Wanted: 4/-24—, ? Zfipi p.m. Requester: Phone No.: 0 $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. e: 0. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable coda PERMIT N0. (206) 431-3670 ulred prior to approval. 'road: 6 C,A' ype o nspect on: (-) ' `lam Ma Address: Date Called: _ • Sp: ►a nstructions: Date Wante•: Q % ep, m. Requester: 1 (1104). Phone No.: Si S 1 Cl Inspector: COMMENTS: ,.. '`'y INSPECTION RECORD - I-' /Retain a copy with permit • V., CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ( Approved per applicable codes. C PERMIT No. (206) 431 -36 ❑ Corrections required prior to approval. Date: Zi -51 ❑ . $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcentor Blvd., Suite 100. Call to schedule reinspection. W °n! C41 i µi AVPAt Project Name Address - City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575-4404 TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM _ = /Z0.)ef e 75 Suite # Retain current inspection schedule Needs shift inspection Gary L. VanDusen, Mayor Control No. �2~ Permit. No. V .pproved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Authorized Signature e FINALAPP.,FR1K .F.D. Form P.P. ADDRESS t OWNER; . 1No • FILE COPY understand that the Plan Check approvals are 1 un royal of subject to errors and omissions violation a a p p v any plans d not authorize the Receipt of con - adopted code or ordinance. lans acknowledged. ad�p of tractor's copy ��� By Date Permit No. 1G Z— .ef FIc.% -- to W. V.- . Ft / -4� V4 NZ Sty SEPARATE PERMIT AND APPROVAL REQUIRED 1.1 at at 'bE.M y U%. rz `1%'v- ►..ra .42fftkfk - -_:Ye.... k1hN_�. g t - -- (�QtJS�R�c 17500 til::IL.l•I"I•ICEN'I•ER PARKWAY TUIK.:WILA WASIIIN11ON 9S,tlil5 TRAMMELL CROW TAX LOT AND ID #a '1262:3019110 -07 CM ` OE oV ED NI Jo 2 3 19S2 LEGAL DE=SCRIPTION; SECTION E QUARTER SW :QUARTER. SW QUARTER OF THE SE QUARTER OF SECTION 26, TOWNSHIP 23 N RANGE W E M�Ct��}tJtCpL C2Ac $Zc rtAC,G Cir A'P'PLAtAut -ed RECEIVED CITY OF TUKWIIA JAN 1 it 1992 PERMIT CENTER City of Tukwila 6200 Southcenter Boulevard • Tukwila, Washington 98188 John W. Rants, Mayor Plan Check #B92 -0012: Best Products 17500 Southcenter Py THE FOLLOWING COMMENTS APPLY TO AND BECOME ART OF THE APPROVED PLANS UNDER TUKWILA BUILDING PERMIT NUMBER 61'QO1 . 1. No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Electrical permit shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (277- 7272). 3. All mechanical work shall be under separate permit through the City of Tukwila. 4. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 5. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 6. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1991 Edition), and Washington State Regulations for Barrier Free Facility (1989 Edition). 7. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. Phone: (206) 433.1800 • CM/ Hall Fax (206) 433.1833 "X" REQUIRED INSPECTIONS PHONE DATE APPROVED INSPECT. INITIALS DATE(S) CORRECTION NOTICE ISSUED 1 Footings 431 -3670 2 Foundation 431 -3670 3 Slab and/or Slab Insulation 431 -3670 4 Shear Wall Nailing 431 -3670 5 Roof Sheathing Nailing 431 -3670 6 Masonry Chimney 431 -3670 7 Framing 431 -3670 8 Insulation 431 -3670 9 Suspended Ceiling 431 -3670 10 Wail Board Fastening 431 -3670 X 11 P -Demo 431 - 3670 12 13 X 14 FIRE FINAL Insp: 575 -4407 15 PLANNING FINAL 431 -3670 16 PUBLIC WORKS FINAL 431 -3670 X 17 BUILDING FINAL 431 -3670 SITE ADDRESS: 17500 Southcenter Py CiTY OF TUKWILA Department of Community Development - Permit Center 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 BUILDII(G PERMIT INSPECTION RECORD (Post with Building Permit In conspicuous place) SUITE NO.: BUILDING 69a PERMIT NO. DATE ISSUED: PROJECT: Best Products CALL FOR INSPECTIONS AT LEAST 24 HOURS IN ADVANCE INSPECTOR COMMENT SECTION ON REVERSE) INSPECTION PROCEDURES AND REQUIREMENTS All approved plans and permits shall be maintained available on the site in the same location. 1. FOOTING - When survey stakes and forms are set and rebar is tied in place. 2. FOUNDATION - When forms and rebar are in place. 3. SLAB - If structural slab or if underslab insulation is required. 4. SHEARWALL NAILING - Prior to cover. 5. ROOF SHEATHING NAILING - Prior to cover. 6. MASONRY CHIMNEY - Approximately midpoint. 7. FRAMING - After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping is in place. 8. INSULATION - After framing approval, but before installation of wallboard. Baffles must be installed to keep attic ventilation points clear. 9. SUSPENDED CEILING - Fasten diffusers, lights and seismic bracing. 10. WALL BOARD FASTENING - Prior to taping (see UBC Chap. 47 and Table 47G). 11. 12. 13. 14. FINAL FIRE INSPECTION - Contact Fire Department for their requirements. 15. FINAL PLANNING INSPECTION - Contact Planning Department for their requirements. 16. FINAL PUBLIC WORKS INSPECTION - Contact Public Works Department for their requirements. 17. FINAL BUILDING INSPECTION When all work, corrections, reports and other inspections are complete. OTHER AGENCIES: Plumbing (including gas piping) — King County Health Department — 296 -4732 Electrical — Washington State Department of Labor and industries — 277 -7272 A preconstruction meeting with the Building Inspector may be scheduled prior to starting the job by contacting the Department of Community Development, Building Division at 431 -3670. Although not required, a meeting of this type can often eliminate problems, delays and misunderstandings as the project progresses. 09/14/00 Plan Check No.: K..AN REVIEW COMME v TS Project: 5eST A REQUIRED INSPECTIONS No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296- 4722). Electrical permit shall be obtained through the Washington State Division of Labor and Industries, and all electrical work will be Inspected by that agency (277- 7272). C ' All mechanical work shall be under separate permit through the City of Tukwila. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. O f When special inspection is required, either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building Inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. 7. All structural concrete to be special inspected (Sec. 306, UBC). 8. All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). 9. All high - strength bolting to be special inspected (Sec. 306, UBC). 10. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 11. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 12. Readily accessible access to roof mounted equipment is required. 13. Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 15. Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given in the soils report prior to final inspection (see attached procedure). 16. A statement from the roofing contractor verifying fire retardancy of roof will be required prior to final Inspection (see attached procedure). O . All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 18. All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296 -4787, at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractors responsibility to have a set of plans approved by that agency on the Job site. 19. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 20. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8, shall be special inspected. 22. All wood to remain in placed concrete shall be treated wood. 23. All structural masonry shall be special Inspected per U.B.C. Section 306 (a) 7. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. 25. A Certificate of Occupancy will be required for this permit. o 1. Footings 2. Foundation 3. Slab /Slab Insulation 4. Shear Wall Nailing 5. Roof Sheathing Nailing 6. Masonry Chimney 7. Framing 8. Insulation 9. Suspended Ceiling 10. Wall Board Fastening X 11.17f,e,- -1 12. 13. C 14. Fire Final 15. Planning Final 16. Public Works Final X 17. Building Final Plan Check No.: K..AN REVIEW COMME v TS Project: 5eST A REQUIRED INSPECTIONS No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296- 4722). Electrical permit shall be obtained through the Washington State Division of Labor and Industries, and all electrical work will be Inspected by that agency (277- 7272). C ' All mechanical work shall be under separate permit through the City of Tukwila. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. O f When special inspection is required, either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building Inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. 7. All structural concrete to be special inspected (Sec. 306, UBC). 8. All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). 9. All high - strength bolting to be special inspected (Sec. 306, UBC). 10. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 11. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 12. Readily accessible access to roof mounted equipment is required. 13. Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 15. Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given in the soils report prior to final inspection (see attached procedure). 16. A statement from the roofing contractor verifying fire retardancy of roof will be required prior to final Inspection (see attached procedure). O . All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 18. All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296 -4787, at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractors responsibility to have a set of plans approved by that agency on the Job site. 19. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 20. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8, shall be special inspected. 22. All wood to remain in placed concrete shall be treated wood. 23. All structural masonry shall be special Inspected per U.B.C. Section 306 (a) 7. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. 25. A Certificate of Occupancy will be required for this permit. o City of Tukwila *ILA FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Fire Department Review Control #B92 -0012 (512) Re: Best Products - 17500 Southcenter Parkway Dear Sir: January 21, 1992 John W. Rants, Mayor The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. All modifications to sprinkler systems shall have the written approval of the Washington Survey & Rating Bureau, Factory Mutual Engineering or Industrial Risk Insurers, then by the Fire Department. No sprinkler work shall commence without approved drawings. (City Ordinance #1528) (NFPA 13, 1-9.1) (UFC 10.307) All sprinkler drawings shall be prepared by companies licensed to perform this type of work. Drawings shall first be approved by the Washington Survey & Rating Bureau, Factory Mutual Engineering or Industrial Risk Insurers, then by the Tukwila Fire Department, No sprinkler work shall commence without approved drawings. (City Ordinance #1528 & NFPA 13, 1 -9.1) (UFC 10.305) Maintain sprinkler protection for all enclosed areas. (NFPA 13, 4- 1.1.1) (UFC 10.302) Contact the Tukwila Fire Department, Fire Prevention Bureau to witness all required inspections and tests. (NFPA 13, 1 -10.2) (UFC 10.305(b)) 2. This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the Page number Yours truly, cc: T.F.D. file ncd City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 John W. Rants, Mayor adopted Fire or Building. Codes does not imply approval of such condition or violation. � �� -rte. The Tukwila Fire revention Bureau CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431 -3670 PROJECT: ADDRESS: DATE: PLAN REVIEW 1�� c obuC 5 `7 50D u C e.vz... ._sAtiS lS ?c-c,cv2 ma c., b cP t� o g- 'To 0 NL vv pt R E.f- js �J�r I C 1\VC- i i t-1 SPACES PLAN CHECK NUMBER S 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 Prepared by: '