HomeMy WebLinkAboutPermit 6771 - Pool Building - Reroof6771 91-392 pool reroof Permit 6771 - Pool Reroof TYPE OF CONST.: Reroof UBC EDITION (year) 1988 SETBACKS: N - S -. E - W- UTILITY PERMITS REQUIRED? (through Q Yes ®No Public Works) FIRE PROTECTION: Q Sprinklers 0 Detectors ( ] N /A ZONING: BAR /LAND USE CONDITIONS? .0 Yes J No CONDITIONS (other than those noted on or attached to permit/plans) PLEASE SEE ATTACHED "REROOF CONDITIONS" REGARDING VERIFICATION OF ROOF CLASSIFICATION. A MINIMUM CLASS "B" ROOF IS REQUIRED. CITY OF TUKWILA Dept. of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 BUILDING PERMIT NO. DATE ISSUED: SITE ADDRESS PROJECT NAME/TENANT PR •P -' • ADDRESS CONTRACTOR Roofing Corp. Northwest 14328 Linden Avenue North, Seattle, WA WA. ST. CONTRACTOR'S LICENSE # ROOFICNO99JJ ADDRESS ARCHITECT ADDRESS APPROVED FOR ISSUANCE BY: CERTIFICATE OF OCCUPANCY NO. Cj a 6100 Southcenter Bl SUITE # Jonathon Pool 1342 N.E. 43rd #710, Seattle, WA N BUILDINU PERMIT (POST WITH INSPECTION CARD AND PLANS IN A CONSPICUOUS LOCAT ON) FEES DESCRI P:TION: `:i' ''':;' BUILDING PERMITFEE: BUILDINGSU RCHARGC :< OTHER TOTAL PLAN CHECK NO.: 91 - 392 PROJECT INFORMATION Pool Jonathan ASSESSOR ACCOUNT # 359700- 0221 -48 TYPE OF [-New Building U Addition U Tenant Improvement (commercial) U Demolition (building) (J Grading/Fill WORK: Q Rack Storage J Reroof 0 Remodel (residential Q Other: DESCRIBE WORK TO BE DONE: Nail down base (28 lb.) over existing hot tar roof, apply modified bitumen roof . USE FLOOR SQUARE FEET SQUARE FEET OCC. LOAD OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. SQUARE OCC. LOAD FEET LOAD TOTAL SQUARE FEET TOTAL OCC. LOAD BUILDING OFFICIAL PRINT NAME: /�%l.� 5 � G I iyi COMPANY:,/ ,,, DATE ISSUED: POO VALUE OF CONSTRUCTION - $ 10,830.00 PH DATE: �:1>26.OQ 4 `5'fl NE PHONE EXP. DATE PHONE R #' SIGNATURE: DATE: !` 67 17 43 -7962► ZIP 98105 165 -2920 ZIP 98133 4 -11 -91 ZIP 'DATE> 1:1W9:1` I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of lay and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. his permit shall become null and vol if th work is not commenced within 180 da from the date'o. issuance, or if the work is suspended or abandoned. fora`. perio d of 180 days from the last inspection PERMIT NO. CONTACTED [__.eft nele,_ 2_, DATE READY DATE NOTIFIED Q 11 `'1 c� - 6 l (init.) —413 PERMIT EXPIRES 2nd NOTIFICATION BY: � Init. ) BY: Init. AMOUNT OWING 3RD NOTIFICATION BUILDING "ERMIT APPLICATION TRACKING PLAN CHECK NUMBER pI��ABTiM>�N . BUILDING - Q`j -q initial review O FIRE O PLANNING O PUBLIC WORKS O OTHER 1so BUILDING - final review REVIEW COMPLETED PROJECT NAME SITE ADDRESS INIT: INIT: (ROUTED Pc , airlD1/4then 10c DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. �SQU114E CONSULTANT: Date Sent - FIRE PROTECTION: ( ] Sprinklers FIRE DEPT. LEITER DATED: ZONING: REFERENCE FILE NOS,: INIT: MINIMUM SETBACKS: N- UTILITY PERMITS REQUIRED? PUBLIC WORKS LETTER DATED: TYPE OF CONSTRUCTION: S- Yes fl No SUITE NO. INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". BUILDING SQUARE FOOTAGE/OCCUPANCY INFORMATION (to be filled out by Plan Checker) SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE CCC. O A SQUARE SQUARE OCC. LOAD OCC. L D TOTAL DARE FE TOTAL E� L D FEET FEET SQ ET OCC. LOAD Date Approved - Detectors INSPECTOR: BAR/LAND USE CONDITIONS? Erma UBC EDITION (year): N/A SITE ADDRESS SUITE # 6, 1 co �7,. 1 2. b3 Lob) VALUE OF CONSTRUCTION - $ jo 30 , or) ASSESSOR ACCOUNT # R .CO -- 3! — y2) P13OJECT NAME/TENANT • �c'-= f .. c: . (JL_ TYPE OF New Building • Addition Tenant Improvement (commercial) Ll Demolition (building) WORK: 0 Rack Storage 0 Reroof 0 Remodel (residential) 0 Other DESCRIBE WORK TO BE DONE: // ; -� 11- V,) L Bic t.]4 ) n o LIZ_ A ( ` . . n St( � - (L 11 i �a ,p, A piv c � ri�l (=O R1 - TLi �i t / nn '-�' BUILDING USE (office, ware ouse, etc.) (75E-cam[ cE NATURE OF BUSINESS: U X2 2 C`)Ck. WILL THERE BE A CHANGE IN USE? .,No 0 Yes If Yes, new building requirements may need to be met. Please explain: SQUARE FOOTAGE - Building: Tenant Space: Area of Construction: hi 54- 7 oaf) OR HAZARDOUS MATERIALS IN THE BUILDING? WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE JLNo O Yes IF YES, EXPLAIN: PROPERTY OWNER" ,Jc k\I ��cl r� C PHONE 7' '" rlcl.6i 9 ZIF `Z)C� ADDRESS (3(4 , E. ��J l?1J i C)T - (: CONTRACTOR ,'):°�^-/ r-� 9(f 62 t ' l ., u 1L 7)7 PHONC (v�"' 24:110 ADDRESSCui t � L „ j z=� ZIP9jj 3 , WA. ST. CONTRACTOR'S LICENSE # �.ac�'. i �x(ng`ll Ty EXP. DATE 1 e ARCHITECT - : }, c PHONE ADDRESS ZIP CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 ........ ;;A, OTHER: DESCRIPTION AMOUNT BUILDING PERMIT FEE PLAN CHECK FEE BUILDING SURCHARGE.: :'.TOTAL` - PLAN CHECK NUMBER D .EXAMINED THIS. APPLICATION ANU Kt �+� IZE.D TO APPLY. FOR THIS .PERMIT DATE EREBY :..CERTIEY,THAT HAVE TRUE AND CORRECT, t D i SIGNATUR BUILDING OWNER OR PRINT NAM AUTHORIZED Cs- L- �, {�-j7 _ t70 AGENT ADDRESS iq G L 6)o kb CONTACT PERSO APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431 -3670. DATE APPLICATION ACCEPTED BU1LDft PERMIT APPLICATION DATE APPLICATION EXPIRES PHONE RCPT- # Q q PHONE ,. /Act DATE: CITY2t -`�( 33 COMMERCIAL NEW COMMERCIAL BUILDINGS/ADDITIONS . Completed building permit application (one for each structure) Assessor Account:Number • Two sets (2) of the folloWing:.- ...; :;;;.• ed 1 - 1 Soils report stamped by a Washington State, licensed engineer • ; ; ; •: : ; • Topographical survey • [j Energy calculations stamped by a Washington state licensed engineer or architect .• •••• • ; : • ri• Legal description :.•••• ; ; • • " : • : Working draVvings stamped by a Washington State licensed architect, which include: Li Specifications ; ' ; • ,,..;;.; . „ Structural calculations stamped by a Washington State boons „ •, „ • • •••• ••• H... •••:•..'••• • ; :: Architectural drawings • • Structural drawings Mechanical drawings Elevations • Civil drawings .... .. .. . .... . . • . ...... . ..„.. ......... .. . ........ . . ... Landscape Completed ulity permit appllcaon (one for onbre project) Six (6) sets of civil drawings . . NOTE:•;) c submittal U i re Men ••••. • • • • • • • • • .•, ..• "' " ....... .. ' .. . . . •-•••• • '' • •• • '' '' . ' RACK• 'Agie . : • t;46():00ig of plans which include Buildinci floor plan showing ••..: ...•:••••• : Entire space where racks will be Exit doors DiMensiOna of all aisles .: • : . . NOTE dimensions °freaks (height; and length),.pisles and exit ways on plan:. , • .....:-....... - ... ..::. '''. -::.'.::":: ..' ;.: :. I... .....:: '........ ....: ; ;:: . ..... ' ;:. . .: ::: : ; .....:...',..1..„ :::.. .. .:: -, . • . -.. Structural calculations stamped by a Washington State licensed engineer (rack storage 8' and oyer) „ .:—..:.-- .. H. ''. • :, ' - - 1. . :.• : : ..''. : - ' • RESIDENTIAL — • ' : ' ''' ' NEW.siNpLEtFAMILY. Completed building permit application (one for each structure) •.. Legal. description ••••;;.;,;;:h.: Assessor Account Number • • .1 • • ' E1 Two sets (y w orking • • .......... • drawings . • whi inc lude . • . -.• -.” Site . .-.•-•.. ••• • .•.• • • • ..• • . . plan (On 'plan; show closest hydrant locat Foundation plan include access to btitiding; • • Floo • • p • •••• .: • -... width and length of • • • • Reef plan '.•••••,••• • Building ..elevations . (all Building 'ore Sieetibn • ' ' . ' '' ' I .eviiishinlitOn.State:EnargY Code data SUBMITTAL CHECKLIST CtiMpleted utility permit application • Six (6) sets of site plans showing utilities NOTE ';Building site plan and utility site plarinlay be combined .' See utility permit application and checklist for specific sUbtnittalceotilrenunts. , Additional topographical and soils information maybe required • , • '''' ..... .... COMMERCIAL TENANT.IMPROVEMENTS:••••:.;' • Completed bUllding permit application (one Assaisor Account Two (2) sets of construction plans which Include Site plan • Location of tenant bpace • Existing and proposed parking • • •••• • • •••• .,':LarldsCaPe,Plar(1f:aPPliCable;;Le,.;;IChantja,:af,..Use), Overall building plan .Use of adjaCepti(common.Wall) tenant. ''''''' ...,Overall:idimensions of building I or say foota Floor. plan of 'proposed tenant .space speCii.:Plen*itli:bse:OfeaCh labelled Exit doors egress patterns New walls, existing wall, and Walls to be demolished Construction details •.• „.... Cross sections showing wall construction and method of foi::f1016e Structural calculations stamped by a Washington State licensed • NOTE If any utility work le . 'application and plans .. . . • : . . , . .. .. . . . .. • . ....... .. •••• 14 ER00 F• • "..:"•• . . .. . . .. • . materia .. ... ... - NOTE A certification letter is required pnor to final Inspection and sign • • . .... . . : •••• • ; ; ; " : • Completed building • located • ... • • • • •. ••••••••-, .••••••:••:• • • .•,•• ; . • . n Two (2) sets of plans which 1--1n.'9c!OL!.. location of antenna/satellite dis Details antenna/satellite dish::and method of attaOhntent .COrapleied buliding oi rippliaation (one:for each structure •••• . Assessor Account Number . . . Narrative describing existing root Material. being removed, and . . . .:.; • • - : . . • • . . . : : : : RESIDENTIAL REMODELS • , ....,.. . . I Completed building permit :1 Assessor Account Number ele' '3„—ticii-.i.::,....,..... • . :11 any g:„OroPb7P 77. • • ;:'•::::::,";::.:S...... :'•'' : . ‘ ''. p e r mit • - . 'f EtitilitY work . " • Structural .... ,,.. .: (3uIllir1 1..itiiiii6g..0! N :iiifin.: . ... ' • ' '.: provide u tility . ' .:..'..... and plans must be REROOFS , Completed . s i building P.erMit:apPliOatien .Assesaor. Account NuMbor„ .:......,............,......„., ..,,,.. . :: , :. Narrative ativedeacribing ..eXiStingroof;iti aterial being removed, and ... :....,..:,....... .. material being tnstalled .... ...„ ...,.......,,, ,. . .... ..,... :. : ., , , ., ,.., N OTE of te.:;1er:ijii 1: ‘ r: : . : r .:.... :t "..1', 117 .. : '...',. :I .'.. 7 7...! 11. .1" n ..... a . h ... c1's19 7.:„.. : .. • NOTE: keertificationletterls required p rior I ,., Two (2 ) sets of working drawings which include Site plan • :•.••••••••.• ions (all • • • ro o ype o nspe on: 4 /-� es es � t•te a e': // Special Instructions: /� / Oo. -� ` '' I ' Date Wanted: Requester: Phone No.: Approved per applicable codes. r, INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206) 431 -3 ❑ Corrections required prior to approval. ❑ $30.00REINSPECTION FE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100.. Call to schedule reinspection. Inspector: Date: CITY OF:TUKWILA DEPARTMENT: OF COMMUNITY DEVELOPMENT - BUILDING DIVISION. 6300 Southcenter Boulevard, Tukwila, Wa 98188 (206) 431 -3670 Ilimmewook 14328 Linden Avenue North Seattle,Washington 98133 Phone:( 206) 365 -2920/ ax:(206)365 -1668 ROOFING CORPORATION NORTHWEST HAS INSTALLED A ROOF MEMBRANE ASSEMBLY CONSISTING OF TARMAC ROOFING SYSTEMS INC. SPECIFICATION #: T -5 WHICH MEETS OR EXCEEDS THE. REQUIREMENTS FOR CLASS B ROOF. DATA SHEET ENCLOSED. THIS ROOF WAS INSTALLED AT 6100 SOUTHCENTER BOULEVARD UNDER CITY OF TUKWILA BUILDING PERMIT NUMBER. 6771.: 22 Specifications T -5 ROOF RETROFIT — SMOOTH OR GRANULATED EXISTING SURFACE (WITH NO NEWIADDITiONAL INSULATION) Specification T-5 Deck (Slope: Water must drain within 48 hours.): Base Membrane: Tarmac SBS Base, Stormshield, SBS Torch Base, Poly Base, any 25 -28 Ib. fiberglass- reinforced base sheet meeting ASTM D -2178 Type V; or any 43 Ib. coated organic felt base sheet meeting ASTM D -2626. Base Membrane Attachment Methods: 1. Above base membrane or vented base sheet attached by spot - applied hot asphalt or mechanical attachment. 2. Above base membrane fully bonded with hot asphalt. 3. If existing roof surface is well attached to the substrate, no base sheet is required. Finish Membrane: Select finish membrane from Tarmac product line and solid -bond to base membrane. Application (starting at low point of roof); 1. Remove all dirt and debris; then repai[ blisters /splits in existing membrane. Replace damp /rotted components, including cants and decking, Hailers, etc, 2. Prim a existing surface with asphalt primer meeting ASTM D41 -78 at the rate of Ito % gals. per 100 sq. ft. 3, If base membrane is to be used, it must be mechanically fastened; priming eliminated. 4. Install Tarmac finish membrane with correct bonding method. 5. Complete flashing details per specification and top -dress finish surface where required, When used In the shaded area,,,Tarmao "APP AS requires protectIveeoatIng for warranty purposes UNDERWRITERS LABORATORIES TESTING FOR PUBLIC SAFETY �-•-• rNc. o BUILDING MATERIALS DIRECTORY 1989 Contains Listings and Classifications in effect as of December 16, 1988 NOTE: Special attention is directed to the information contained in the second paragraph on Page 3. TARCO OF TEXAS INC, BELTON TX 76513 ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT Asphalt organic felt for use in construction of Class A. B and C roofing systems. Asphalt glass fiber felt for use in construction of Class A, B and C roofing systems. . TARMAC ROOFING SYSTEMS INC, WILMINGTON DE 19810 R13228 (N) R11715 (N) SINGLE PLY MEMBRANE SYSTEMS 1. Dock: NC Class A— Ballasted Incline 2 Membrane "Tarmac APP4S". - Tarmac APP Black Diamond" or "Tarmac APP4M" with seams torched, laid loosely. Surfacing: River bottom stone 13/4 to 1.1/2 in. dismI, 1003 lbs/sq, 2. Deck: C -15/32 Incline: 1/4 Insulation: Glass fiber, penile or wood fiber board 0 in. offset joints. 3/4 to 2.1/4 in. max. Ply Shoot Type 15 asphalt saturated organic felt Membrane "Tarmac APP4S ".'Tarmac APP Block Diamond" or "Tarmac APP4M ", hest fused. Surfacing: Roofing gravel, 400 lbs/sq. 3. Deck: NC Incline 1/4 Base short IOptlonelk Type 15 organic felt mechanically listened Insulation (Optlonalk Glass (iber, partite or wood fiber, 2.1/2 in. max. Ply sheet Type 62, adhered with hot roofing asphalt. Membrane: 'Tarmac APP4S ",'Tarmac APP Black Diamond" or "Tarmac APP4M', host fiwd. Surfacing: River bottom stone 13/4 to 1.1/2 in. diameter) 1000 lbs/sq. 4. Deck: C -15/32 Incline 1/4 All joints blocked with 2 x d's. Insulation: One or more layers of one of the following insulation mechanically fastened, 1.0 in. minimum - no maximum. Fiberboard Polito Celotex Corp's 'Therms* Hy -Tec" Cleats* Corp's "Thermos H•Tec Plus 2" . Base Sheet Celotex Corp's "Vaporbpr GB ". Typo 61. hot mopped to the insulation. Membrane: "Tarmac SBS -170 ", "Tarmac SBS -4M" or 'Tarmac SBS Black Diamond ", (modi- fied bitumenl, hot mopped to the base sheet Surfacing: Gravel at 400 lbs/eq in hot rooting asphalt at 00 lbs/sq. 5. Deck: NC Incline 1 Insulation: One or more layers of one of the following insulation mechanically fastened, 1.0 in. minimum - no maximum. Fiberboard Penits Celotex Corp's •'Thermax Hy-Tec" Calcites Corp's " Thermax Hy-Tec Plus 2" Base Sheet Celotex Coro's. Type G•1, "Vaoorber GB" hot mopped to the insulation. Membrane: "Tarmac SBS•170 ".'Tarmac SBS -3M" or 'Tarmac SBS Black Diamond" (modified bitumen). hot mopped to she base sheet. Surfacing: Gravel at 400 lbs/sq in hot roofing asphalt at 00 lbs/sq. 6. Deck: NC Incline: 1 Insulation: Polylsocyanurato, glass fiber, partite, wood fiber, mechanically fastened or adhered with hot roofing asonalt any thickness. Bs** Sheet Tvpe G2, mechanically fastened or adhered with hot roofing asphalt 'Membrane Tarmac SBS-170". "Tarmac SBS-4M" or 'Tarmac SBS Black Diamond". adhered with hot roofing asphalt Surfacing: Gravel. 7. Omit C•15/32 Incline. 1 •Alt joints blocked with 2 x 4's. Insulation: Glass fiber, penile, 3/4 in. minimum, joints in insulation must be offset 6 in. from joints in deck, mechanically Iaetant°. Baas Sheet Type G2, mechanically (moonset or adhered with hot roofing asphalt Membrane: 'Tarmac SBS - 170", 'Tarmac SBS -4M" or 'Tarmac SBS Black Diamond" adhered with hot roofing asphalt. Surfacing: Gravel. B. Dock: NC Incline 1/2 Insulation: Polvisocyanurate. glass fiber, penile, wood fiber. mechanically fastened or adhered with hot roofing asphalt any thickness. Sass Sheet Type G2, mechanically fastened or adhered with hot roofing asphalt LOOK FOR MARK ON PRODUCT e ,46 ROOF COyERING MATERIALS (TEVT) ..r ROOFING SYSTEMS (TGFU)—Continued Membrane: "Tarmac APP.4S ", "Tarmac APP•4M" or 'Tarmac Black Diamond ", hot fused in place. Surfacing: Gravel. 9. Deck: NC Incline 1/4 Insulation: Polyisocyanurate. glass fiber, penita, wood fiber, 3 in. maximum, mechanically fas• tenet Base Sheet "Tarmac Potyoase ", mechanically fastened or adhered with hot roofing asphalt Pty Sheet 'Tarmac Polybase ", adhered with hot roofing asphalt Membrane: "Tarmac SOS -4M" adhered with hot roofing asphalt Surfacing: Gravel. Class B— Baltaated 1, Deck: NC Incline: 2 Insulation: Glass fiber, panne, wood fiber, 2.1/2 in. maximum. mechanically fattened or ad- hared with hot roofing asphalt Blase Sheet Type G2, mechanically fastened or adhered with hot roofing asphalt Membrane: 'Tarmac SBS- 170 ", 'Tarmac SOS-4M" or "Tarmac SBS Black Diamond ", adhered with hat roofing aspnalt Surfacing: Gravel. 2. Deck: C'15/32 Incline: 1/2 'All joints blocked with 2 x 4's. Insulation: Glass fiber, partite, wood fiber, 3/4 to 2.1/2 in., joints in insulation must be offset 8 in. from joints in deck, mechanically fastened. . Bess Sheet Type G2. mechanically fastened or adhered with hot roofing asphalt Membrane 'Tarmac AAP"4S ",'Tarmac APP-4M" or "Tarmac Black Diamond ", heat fused. Surfacing: Gravel. 3. Deck: C.15/32 • Incline 1/4 'All joints blocked with 2 x 4's, Base Sheet Type G2. mechanically fastened. Membrane 'Tarmac AAP-4S", 'Tarmac APP.4M" or "Tarmac Black Diamond ". heat fused. Surfacing: Gravel. 4. Deck: C -15/32 Incline: 1 'All joints blocked with 2 x 4's. Bass Sheet Type G2. nailed. Membrane: "Tarmac SBS -170 ", "Tarmac SBS -4M" or 'Tarmac SOS Black Diamond ", adhered with hot roofing asphalt Surfacing: Gravel. B. Dectt C -15/32 Incline 1/2 'All joints blocked with 2 x 4's. !mutation: Celotez "HyTec ", 2 in. minimum, joints in insulation must be offset 8 in, from joints in deck. mechanically fastened. Bate Shut Type G2. mechanically fastened or adhered with hot roofing asphalt. Membrane: 'Tarmac S135.170", "Tarmac SBS -4M" or "Tarmac SBS Black Diamond ", adhered with hot roofing asphalt Surfacing: Gravel. 8. Deck: C -15/32 Incline 1/2 'All joints blocked with 2 x 4's. Insulation: Celotex "Hy-Tec ", 2 in. minimum, joints in insulation must be offset 8 in. from joints in deck. mechanically fastened, Base Sheet Type G2, mechanically fastened or adhered with hot roofing sspnalt Membrane: 'Tarmac APP-4S", 'Tarmac APP.4M" or 'Tarmac Black Diamond ", heat fused • Surfacing: Gravel. r' Class A —Fully Adhered 1, Deck: NC _��.. Incline 1/4 Insulation: (Optional) Glass fib partite or wood fiber board. Pty Sheet Type G-2. mecha nically fasten Membrane 'Tarmac APP -4S" ' A PP Black Diamond" or "Tarmac APP-4/4". hist-fused, Surfacing: "Karnak =97 ", 1 g al /sq. 2, Deck: NC Incline 1 Insulation: Polyisocyanurate, gl ass fiber, p erlits, wood fiber, mechanically fastened of adhered with hot roofing asphalt a ny thi Base Sheet Type G•2. m faste or adhered with hot roofing asphalt Membrane 'Tarmac SOS-170", 'Tarmac SBS -4M" or 'Tarmac SBS Black Diamond ", adhered with hot roofing asphalt Surfacing: Karnak Chemical Corp., "Karnak it97 Fibrated Aluminum Asphalt Roof Coating ", 2• 1/2 gel /sq. 3. Deck: C-15/32 Incline: 1 ' 'All joints blocked with 2 x 4'a, Insulation: Glass fiber, partite. 3/4 in. minimum, joints in insulation must be offset 8 in. from joints in deck. mechanically fastened. Base Sheet Type G•2, mechanically fattened or adhered with hat roofing asphalt Membrane: 'Tarmac SOS -4M ". adhered with hot roofing asphalt Surfacing: Karnak Chemical Corp., "Karnak 1x97 Fibrated Aluminum Asphalt Roof Coating ", 2• 1/2 gal/sq. 4. Deck: NC Incline 1/2 Insulation: Polyisocyanurate, glass fiber, penile, wood fiber, mechanically fastened or adhered with hot roofing asphalt. any thickness. Base Sheet Type G•2. mechanically fastened or adhered with hat roofing asphalt Membrane. 'Tarmac APP -4S ", 'Tarmac APP.4M" or "Tarmac Black Diamond ", hut fused in place. Surfacing: Karnak Chemical Corp., "Karnak 497 Fibrated Aluminum Asphalt Roof Coating ", 3 gat/sq. 5, Deck: NC Incline'. 1 Insulation: lOptionall Penile. glass fiber, polyurethane, isocyanurete. phenolic combination iso- cyanurate /perlrte, polyurethanerpanne or wood fiber. any thickness, hot mopped or nailed. LOOK FOR MARK ON PRODUCT °.00R COVERING MATERIALS ITEM ROOFING ,SYSTEMS (TGFU)- Continued fufombrane 'Tarmac APP 4S ", 'Tarmac APP Black Diamond" or .'Tarmac APP 4N1", "S8S- 4M", "S8S•5M". "S8S -170" or SBS double cov.rags heat fused or hot mopped in place. Surfacing: Grundy Industries. Inc. "al MB Aluminum Roof Coating" at 1.2 psVsp. Clear B- -Fully Adhered • 1. Clock: NC Inclines 2 Insulation: Glass fiber. perlite. wood fiber, 2.1/2 in. maximum. mechanically faatanad or ad- hered with hot roofing asphalt. Raw Sheet Type G-2, mechanically fastened or adhered with hot roofing asphalt Membrane 'Tarmac S85-170", 'Tarmac S8S - 4M" or "Tarmac SBS Slack Diamond', adhered with hot roofing asphalt. Surfacing: Karnak Chemical Corp., "Karnak $97 Fbrated Aluminum Asphalt Roof Coating ". 2- 1/2 gal/so. 2. Deck C•15/32 • Incline 1/2 . " 'A11 joints blocked with 2 x 4's. Insulation: Glass fiber,.perlite. 3/4 to 2.1/2 in.. joints in insulation must be offset 6 in. from joints in deck. mechanically fastaned Sawa Shoat Type G•2. mechanically fastened or adhered with hot roofing asphalt. . Marnbnne 'Tarmac APP - 4S ", 'Tarmac APP.AM" or 'Tarmac Black Diamond ", heat fused Surfacing: Karnak Chemical Corp.. "(smelt *97 Fbrated Aluminum Asphalt Roof Coating ", 1 1/2 gar/sq. Oack:;C +15/32, Incllnec • 'Ail joints blocked with 2 x I s. Baas Sheet Type G-2, mechanically fastened. PAernbrono:'Tarmac APP-4S ", 'Tarmac APR4M" or,'Tarrr!Pc 81ack.;Dlamond", haat fused.,. Surfacing: Kamak Chemical Corp.. :" Kamak #97 F brsud _ Alumm inu-Asphalt Roof'Coadny ";' 1 = -,1/2 gsVs4 ' 4 Deck C- 15/32 • Incline. 1/2 'All joints blocked with 2 x 4's. Saes Sheet Type G•2, nailed. Membrane 'Tarmac SBS -4M ", adhered with hot roofing asphalt Surfacing: Karnak Chemical Corp.. "Karnak $97. Fbrated Aluminum Asphalt Roof Coating ", 2. 1/2 gal/so. • S. Dock: C•I5/32 Inclines 1/2 . 'All joints blocked with 2 x 4's, Insulation: Calcites "Hy-Too", 2 in. minimum, joints in insulation must be offset 6 in. from joints In deck. mechanically fastened. • Baas Sheet Type G.2..mochanically fastened or adhered with hot roofing asphalt FAembrsne "Tarmac SBS"41r. adhered with hot roofing asphalt Surfacing: Karnak Chemical Corp" "Kamak $97 Fbratad Aluminum, Asphalt Roof Coating ", 2• 1/2 gal/sq. 6. Dick: C•15/32 1nclln.c 1/2 'All joints blocked with 2 x 4's. .Insulatiora Calais* "Hy.Tec ", 2 in. minimum, joints in insulation must be offset 0 in. from joints in Back. mechanically fastened. AA.. Riwastir Tvne r.7 m..chanrealiv fastened or adhered with hot roofing asphalt'. • Project: 5- Type of Inspectio • Address: / n / 00 C c Date Called: Spe al Instructions: /� = h1 >V7" fir" C) Date Wanted: /0 - 2- LI- q i am. p.m. Requester :... Phone No.: 45' Z- U l� -1 /eS t I SPE CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 O Approved per applicable codes. Inspector: } INSPECTION RECORD 0 Retain a copy with permit de_ Corrections required prior to approval. COMMENTS: ;/"h sit" r-w•./ NZ/4 c a ,i-S s JAM P f 54 2 cr fah AZ e p Date: (206) 431 -3670 f e e,4 2 >e- O ' $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431 -3670 INSPECTION RECORD 6300 Southaenter Boulevard — #100 Tukwila Washington 98188 PERMIT NO. (, 77/ PROJECT: / / ,� u ix:44" SITE ADDRESS: 6Z4 cSc C7�P � ��� DATE CALLED: 2 -- 2.. ,. TYPE OF INSPEC TION: DATE WANTED:- - �1 / a SPECIAL INSTRUCTIONS: 7 `3 b REQUESTER: PHONE NO.: INSPECTION RESULTS /COMMENTS: p, , f „ e _ A ' - - C} „ e."%e∎ D ATP ! 4 i._1 _e"_C., > INSPECTOR: GL. .P 10��J17"1 CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431 -3670 INSPECTION RECORD 6300 Southaenter Boulevard — #100 Tukwila Washington 98188 "X" REQUIRED INSPECTIONS PHONE DATE APPROVED INSPECT. INITIALS DATE(S) CORRECTION NOTICE ISSUED ■ 1 Footings 431 -3670 2 Foundation 431 -3670 3 Slab and/or Slab Insulation 431 -3670 4 Shear Wall Nailing 431 -3670 5 Roof Sheathing Nailing 431 -3670 6 Masonry Chimney 431 -3670 7 Framing 431 -3670 8 Insulation 431 -3670 9 Suspended Ceiling 431 -3670 10 Wall Board Fastening 431 -3670 X 11 Pre - Reroof 431 -367 12 13 14 FIRE FINAL Insp: 575 -4407 15 PLANNING FINAL 431 -3670 16 PUBLIC WORKS FINAL 431 -3670 ■_-- 17 BUILDING FINAL 431 -3670 __ CITY OF TUKWILA Department of Community Development - Permit Center 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 SITE ADDRESS: 6100 Southcenter Bl BUILDUG PERMIT INSPECTION RECORD (Post with Building Permit In conspicuous place) SUITE NO.: BUILDING (o11 I PERMIT NO. DATE ISSUED: PROJECT: Pool, Jonathon CALL FOR INSPECTIONS AT LEAST 24 HOURS IN ADVANCE (INSPECTOR COMMENT SECTION ON REVERSE) INSPECTION PROCEDURES AND REQUIREMENTS All approved plans and permits shall be maintained available on the site in the same location. 1. FOOTING - When survey stakes and forms are set and rebar is tied in place. 2. FOU DATION - When forms and rebar are in place. 3. SLA - If structural slab or if underslab insulation is required. 4. SHEARWALL NAILING - Prior to cover. 5. ROOF SHEATHING NAILING - Prior to cover. 6. MASONRY CHIMNEY - Approximately midpoint. 7. FRAMING - After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping is in place. 8. INSULATION - After framing approval, but before installation of wallboard. Baffles must be installed to keep attic ventilation points clear. 9. SUSPENDED CEILING - Fasten diffusers, lights and seismic bracing. 10. WALL BOARD FASTENING - Prior to taping (see UBC Chap. 47 and Table 47G). 11. 12. 13. 14. FINAL FIRE INSPECTION - Contact Fire Department for their requirements. 15. FINAL PLANNING INSPECTION - Contact Planning Department for their requirements. 16. FINAL PUBLIC WORKS INSPECTION - Contact Public Works Department for their requirements. 17. FINAL BUILDING INSPECTION - When all work, corrections, reports and other inspections are complete. OTHER AGENCIES: Plumbing (including gas piping) — King County Health Department — 296 -4732 Electrical — Washington State Department of Labor and Industries — 277 -7272 A preconstruction meeting with the Building Inspector may be scheduled prior to starting the job by contacting the Department of Community Development, Building Division at 431 -3670. Although not required, a meeting of this type can often eliminate problems, delays and misunderstandings as the project progresses. =um