Loading...
HomeMy WebLinkAboutPermit 6777 - Ballard and Company - Offices6777 91-372 ballard and company 625 strander boulevard Permit 6777 - Ballard and Company PROPERTY OWNER The Koll Company PHONE 575 -07651 ADDRESS 601 Strander Boulevard, Tukwila, WA Z1P 98188 CONTRACTOR Zion Construction Inc. PHONE 575 -0367 ZIP 981.88 ADDRESS 992 Industry Drive, Tukwila, WA WA. ST. CONTRACTOR'S LICENSE # ZIONCI * *148MG EXP. DATE 7 - 02 - 92 ARCHITECT Zion Cons.truction, Inc. PHONE 575 -0367 ADDRESS 992 Industr Drive, Tukwila, WA ZIP 98188 TYPE OF CONST.: V _ N UBC EDITION (year) 1988 SETBACKS: N - S -- E- W— UTILITY PERMITS REQUIRED? O Yes ® No ( pubjj Works) FIRE PROTECTION: Sprinklers Q Detectors ei NA ZONING: BAR /LAND USE CONDITIONS? 0 Yes 0 No CONDITIONS (other than those noted on or attached to permit/plans) /1 _ -, CITY OF TUKWILA Dept. of Community Development- Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 BUILDING PERMIT NO. DATE ISSUED: BUILDIN3 PERMIT (POST WITH INSPECTION CARD AND PLANS IN A CONSPICUOUS LOCATION) DESCRIPTION BUILDING: PERMIT FEE : '' PLAN:CHECK:FEE BUILDING' SURCHARGE; >< OTHER AMOUNT 8.1.00 53:.00 RCPT #. DATE ::194.1 9 -.05 91: 1941 9-05- 9j., PLAN CHECK NO.: 91 - 372 PRO.JECT • .•. INFORMATION PROJECT NAME /TENANT Ballard & Company SITE ADDRESS TYPE OF U New Building [J Addition U Tenant Improvement (commercial) U Demolition (building) Li Grading/Fill WORK: 0 Rack Storage 0 Reroof 0 Remodel (residential) 0 Other: DESCRIBE WORK TO BE DONE: Add 35 linear feet of wall to make two offices. SQUARE FEET OCC. SQUARE OCC. SQUARE OCC. LOAD FEET LOAD FEET LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD TOTAL SQUARE FEET TOTAL OCC. LOAD APPROVED FOR ISSUANCE BY: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of lay and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. SIGNATURE: j ?� -L-fl. �- DATE: l6 v . ......................... ..:............................ ils permrt shall become null and void:r the work rs hot commenced within 180 days from ,fhe date of issuance, or if the work rs. suspended or aband for period of:180 days from the'. last inspection:: CERTIFICATE OF OCCUPANCY NO. 625 Strander 81 NIA_ SUITE It BUILDING OFFICIAL DATE ISSUED: VALUE OF CONSTRUCTION - $ 5,629.00 ASSESSOR ACCOUNT # 022330 - 0020 -01 PERMIT NO. CONTACTED PIS DATE READY DATE NOTIFIED " l q i BY ) --{, 3 I3 PERMIT EXPIRES 2nd NOTIFICATION BY: ( init. . MOUNT OWING 3RD NOTIFICATION BY: (init.) BUILDING RT RMIT APPLICATION TRACKING PLAN CHECK UMBER PARTM NT • DATE O PLANNING ti O PUBLIC WORKS O OTHER /7 OBUILDING - ci/13fri final review REVIEW COMPLETED INIT: INIT: INIT: INIT: PROJECT NAME SITE ADDRESS attard C 100 (1) 341 c 6, INSTRUCTIONS TO STAFF ® Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". BUILDING SQUARE FOOTAGE/OCCUPANCY INFORMATION (to be filled out by Plan Checker) FL R< ": SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD TOTAL SQUARE FEET DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. BUILDING - initial review FIRE 0 1 INIT: FIRE PROTECTION: FIRE DEPT. LETTER DATED: C:ONMEN S Sprinklers Detectors INSPECTOR: ROUTED 6 1 is R 12 CONSULTANT: Date Sent - ZONING: REFERENCE FILE NOS.: MINIMUM SETBACKS: N- UTILITY PERMITS REQUIRED? PUBLIC WORKS LETTER DATED: ct TYPE OF CONSTRUCTION: UIREME UITE NO. Date Approved - BAR/LAND USE CONDITIONS? UBC EDITION (year): 1908 TOTAL OCC .LOAD _, W- PROPERTY OWNER - c_i CC..A� 1 . - DESCRIPTION -- A - WO ' iNT :' PHONE c 5 , 6c ADDRESS . BUILDING PERMIT FEE gi.00 1 ail CONTRACTOR 7.1c ) C` r. :,w3s 4.z.,, t...,r,i, ___\ .1Q0_... PLAN CHECK FEE PHONE�s Z `� (1 , :3(.. „,,- 4 _ ADDRESS 9c• z i 1∎3bO�•{ - 0'?c/ B UILDING SURCHARGE ZIPr/�,,I � � L WA. ST. CONTRACTOR'S LICENSE # .--/ i c j . L ,� - � q �,, �, EXP. DATE ARCHITECT ,�v t � ��� •4 vC k, t r _b, -, 1 7 OTHER. PHONE r- .- 07501. _ ZIP ' ?,, ADDRESS '�� r _232, . _.._ ...,.....__...,.. _....._..,..., ................ ,....,... (206) 431 -3670 DESCRIPTION -- A - WO ' iNT :' RCPT #:. - ; :D TE BUILDING PERMIT FEE gi.00 1 ail q- 6-it PLAN CHECK r C i - NUMBER � .. APPLICATION MUST BE FILLED : OUT COMPLETELY PLAN CHECK FEE 5:301,E 1 B UILDING SURCHARGE , f) � OTHER. v TOTAL`. - 1 . s SITE ADDRESS SUITE # (c.%Y '::.2 ` 1 G?.iNI , (\F k?._. RA_) A A i.> VALUE OF CONSTRUCTION - $ c 3 Q (A . 00 ASSESSOR ACCOUNT # 2 x..7 U,30— C:)0 �- CA PROJECT NAME/TENANT E��- \ l \A , V `� `1,^ C,N.,\. �1 \ {`J TYPE OF U New building Addition Tenant Improvement (commercial) ❑ Demolition (building) WORK: CD Storage ❑ Reroof Li Remodel (residential) O Other DESCRIBE WORK TO BE DONE: M h ;3'50 _. Ri. ; k ' { 1 0440610 - tA.) A 0,S :k m►g. c,• r ,r A5 -0,., t .k., rv►,4d,, .z , ..(,,, BUILDING USE (office, warehouse, etc.) / J • NATURE OF BUSINESS: r ��� 1 N. N. V= -NNiC� ''_ Ate-. - ..›s WILL THERE BE A CHANGE IN USE? Us). No U Yes IF YES, EXPLAIN: SQUARE FOOTAGE - Building: ' X13 .) ajnantSpace: 1 i 5C,3 j Area of Construction: Q19 WILL THERE BE STORAGE OR USE OF FLAMMA LE, COMBUSTIBLE OR AZARDOUS MATERIALS IN THE BUILDING? it, No ❑ Yes IF YES, EXPLAIN: CITY OF TUKWILA Department of Community Development - Building Division EXAIVIIN > a ;E� ERE 3Y C RTIFY;THAT I HA IE >! fE AND CORRECT, I SIG ATURE BUILDING OWNER > OR cc(4/ _- AUTHORIZED PRINT NAM m AGENT CONTACT PERSON r, (c APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Corr niird *. epplicetion submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431 -3670. DATE APPLICATION ACCEPTED ADDRESS C c 2, BUILDING PERMIT APPLICATION AC K -- V t) X5 c4(21 - DATE APPLICATION EXPIRES DATE ca- PHONE a ( --O3G9. CITY /ZIP F� , Kc.4.,, /4- 51:?i PHONE 3 C) 3 1 COMMERCIAL ----l— RACK STORAGE Q Completed building permit application Assessor Account Number Two (2) sets of plans, which incude: Building floor :Plan showing • Entire space where .racKs will :be !.Exit doors Dimensions of all aisles anent space floor plan showing rack " storage layout;: exits NO E include dimensions of racks (height, widtfr agd le and exit ways art plan Structural calculations stamped by a Washin engineer (rack storage.B and over) RESIDENTIAL NEW SINGLE - FAMILY DWELLINGS /?DITMONS Completed building permit03lication (one for each structure Legal description ` (\ Assess or Accoutlticlumber T wo .set 2t drawl SIs\plan r. Foundation plan Roar: plan. Roof plan Building elevations (all views Building cross - section • • Structural framing plans Washington ; State Energy Code data.::: SUBMITTAL CHECKLIST NEW COMMERCIAL BUILDINGS /ADDITIONS Completed building permit application (one for each structure Assessor Account Number . Two sets (2) of the following a Specifications 1 ( Structural calculations stamped by a Washington State licensed engineer Bolls report stamped by a Washington State licensed engineer • D Topographical survey Q Energy calculations stamped by a Washington State licensed engineer or architect Legal description Worfdng drawings, stamped by a Washington State licensee architect, which include: • Site plan • `Architectural drawings • Structural :drawings • Mechanical drawings Elevations +::Civil: drawings 'Landscape plan f Completed utility permit application (one for E Six (6) sets of civil drawings NOTE :See utility permit application and checklist for submittal requirements Una license COMMERCIAL TENANT IMPROVEMENTS Completed building permit application (one for each structure or tenant) Assessor Account .Number Two:(2) sets of constructi plan which inclu • Site plan Location of tenant space Existing and proposed: parking El Overall building plan • Tenant loca tlse of adja cen t (com wall) tenan .! • Ov di mensio ns of buil ding or squ foo tag e C Floor p l a n erall of proposed tenant sp • • Tenant sp ace' p lan with use of,e room labelled •. Ex it doors, eg ress :patterns • New. :walls •e xisting wall, and wails to b dem olished • Construction details: • Cross sections showing wail construction and method of attachment for floor.and ceiling C] Structural calculations stamped by a Washington State licensed engineer may be required if structural work is: to be done (2 sets; NOT !f any utlGry wo rk : ls to ba :don s s eparat e uti li • permit . application and plans Gampletetl buildng pormit epplicatjon (one for each structur Assessor Account Number Narrative descnbing'existing roof, material being removed, an material being installed NOTE :A certification letter is required prior to final insPection end off o f the permit • : ANTENNNSATELLITE . piSIiEB ; Completed building permit appilcatic Assessor Account Number T wo (2)sets:ot plans, whichanciude Site Plan (showing building and l ocation of antennalsatellite die < t_ _ Details antenna/satellite dish and method Of attachme Structural calculations stamped by a Washington State licens engineer may be'requlrei . Completed building permit ap :ASsessorAccount• Number Iwo sets •of working drawings; which include entire Completed utility permit application Q Six (6) sets of site plans showing utilities NOTE. ` Building site plan and utility site plan may be combined, See utility permit application and checklist for specific submittal requirements. Adc*tronal topographical and soils information may required if unique she conditions. te;plan Foundation pli Fic+cr rrAn • Roof plan' • Buiildtng elevations (all views Building cross section :Structural: framing p NOTE, If anyutilitywork is to bedone; and plans must be submitted : REROOFS Completed bullctini3 permit application (pm for each : structure Assessor Account Number; Narrativedescnbing existing roof;, Material being Installed NOTE: A certification letter is required prior to finallnspocton and sign - o of the permit ; ro ect r / 1 !It l Q aldEd , T oo nson' :te " 1 I "" - " 9 Address: (ip s � Special ins ructions: Date Wanted: Requester: P No. : 252___ __O .1.32._ Approved per applicable codes. eceipt No,: • INSPECTICN'llge0RD ` ;. Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188. Corrections required prior to approval. Dale: Ul 71 PERMIT N0. (206) 431 - 361'0 o $30.00 REINSPECTION E REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100: Callao schedule reinspection, 4,, PROJECT: 1 a . PERMIT NO. (0 SITE ADDRESS: e . _l Al O. r DATE CALLED: DATE WANTED: REQUESTER: 1 ()'% C J ` Q _ q -9 / ' a TYPE OF INSPECTION: � SPECIAL INSTRUCTIONS: PHONE NO.: 3 .- O a(p""') INSPECTION RESULTS /COMMENTS: r r INSPECTOR: l S / -7---- ° DATE: ) 0 - 9 -9 ) CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431 -3670 _..... i......... ,.�.:..s , ....,w w00.0u00.0..0.0" r.00000.00.nx0400. -n eNt 4•: i{M't a:uJ +>. INSPECTION RECORD 6300 Southcenter Boulevard — #100 Tukwila Washington 38188 PROJECT: OP 0 I i � i PERMIT NO. 01 SITE ADDRESS: La -5ki %Ql' 111 I DATE CALLED: ' TYPE OF INSPECTION: ( I • k WCLI 1 • DATE WANTED: % • • a.m. SPECIAL INSTRUCTIONS: REQUESTER: Ock PHONE NO.: S S- 03(6 INSPECTION RESULTS /COMMENTS: G iv.k6 -- r-o:a.t!--f ..c,, . C..fruA-C INSPECTOR: C DATE: / e-) -, - �'�, CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431 -3670 INSPECTIOIS RECORD 6300 Southoenter Boulevard — #100 Tukwila Washington 98188 Project Name h.4 Address • ,4'2„ Suite # FINALAPP.FRM City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575-4404 TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Retain current inspection schedule Needs shift inspection Approved without correction notice Sprinklers: 4" Fire Alarm: r °fl Hood & Duct: /" Halon: Monitor: _' Pre - Fire: Permits: Approved with correction notice issued Authorized Signature Date Gary L. VanDusen, Mayor Control No . 0 .: $) L. \/ Permit No. „ 7 .F.D. Form F.P. 85 site plan koll commerce center tract ii legal description OF TUKWILA PROVED EP 13 199,1 AS NOTED BUILDING DIVISION floor plan new wall section suspended ceiling sprinkler cross bracing zion construction koll company new wall section floor plan CITY OF TUKWILA 6200 SOUTYICENTER BOULEVARD, TUKWILA, WASHINGTON 98188 Plan Check #91 -372: Ballard & Company 625 Strander Bl PHONE # (206) 433.1800 Gary L. VanDnscn, Mayor THE FOLLOWING COMMENTS APPLY TO AND BECOME P OF THE APPROVED PLANS UNDER TUKWILA BUILDING PERMIT NUMBER . 1. No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Electrical permit shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (872- 6363). 3. All mechanical work shall be under separate permit through the City of Tukwila. 4. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 5. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 6. Any exposed insulations backing material to have Flame Spread.. ,Rating . of 25 or less, and...... material..._sha1l,. bear, identification showing the fire performance rating thereof. 7. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1991 Edition), and Washington State Regulations for Barrier Free Facility (1989 Edition). 8. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. "X" REQUIRED INSPECTIONS PHONE DATE APPROVED INSPECT. INITIALS DATE(S) CORRECTION NOTICE ISSUED 1 Footings 431 -3670 2 Foundation 431 -3670 3 Slab and/or Slab Insulation 431 -3670 4 Shear Wall Nailing 431 -3670 5 Roof Sheathing Nailing 431 -3670 6 Masonry Chimney 431 -3670 7 Framing 431 -3670 8 Insulation 431 -3670 9 Suspended Ceiling 431 -3670 X 10 Wall Board Fastening 431 -3670 11 12 13 1 :,...4 14 FIRE FINAL Insp: 575 -4407 15 PLANNING FINAL 431 -3670 16 PUBLIC WORKS FINAL 431 -3670 % 17 BUILDING FINAL 431 -3670 CITY OF TUKWILA Department of Community Development - Permit Center 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 SITE ADDRESS: 625 Stratider B1 BUILDIMG PERMIT INSPECTION RECORD (Post with Building Permit in conspicuous place) SUITE NO.: BUILDING PERMIT NO. DATE ISSUED: PROJECT: Ballard & Company CALL FOR INSPECTIONS AT LEAST 24 HOURS IN ADVANCE (INSPECTOR COMMENT SECTION ON REVERSE) INSPECTION PROCEDURES AND REQUIREMENTS All approved plans and permits shall be maintained available on the site in the same location. 1. FOOTING - When survey stakes and forms are set and rebar is tied in place. 2. FOUNDATION - When forms and rebar are in place. 3. SLAB - If structural slab or if underslab insulation is required. 4. SHEARWALL NAILING - Prior to cover. 5. ROOF SHEATHING NAILING - Prior to cover. 6. MASONRY CHIMNEY - Approximately midpoint. 7. FRAMING - After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping is in place. 8. INSULATION - After framing approval, but before installation of wallboard. Baffles must be installed to keep attic ventilation points clear. 9. SUSPENDED CEILING - Fasten diffusers, lights and seismic bracing. 10. WALL BOARD FASTENING - Prior to taping (see UBC Chap. 47 and Table 47G). 11. 12. 13. 14. FINAL FIRE INSPECTION - Contact Fire Department for their requirements. 15. FINAL PLANNING INSPECTION - Contact Planning Department for their requirements. 16. FINAL PUBLIC WORKS INSPECTION - Contact Public Works Department for their requirements. 17. FINAL BUILDING INSPECTION - When all work, corrections, reports and other inspections are complete. OTHER AGENCIES: Plumbing (including gas piping) — King County Health Department — 296 -4732 Electrical — Washington State Department of Labor and Industries — 277 -7272 A preconstruction meeting with the Building Inspector may be scheduled prior to starting the job by contacting the Department of Community Development, Building Division at 431 -3670. Although not required, a meeting of this type can often eliminate problems, delays and misunderstandings as the project progresses. 0W14/90 PLL N REVIEW COMMEN( a Plan Check No.: Project: CO 1. 1. No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. REQUIRED INSPECTIONS 2. Plumbing permit shall be obtained through the King County Health Department and plumbing will be, inspected by that agency, including all gas piping (296- 4722). Electrical permit shall be obtained through the Washington State Division of Labor and Industries, and all electrical work will be inspected by that agency (277- 7272). All mechanical work shall be under separate permit through the City of Tukwila. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 6. When special inspection is required, either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. 7. All structural concrete to be special inspected (Sec. 308, UBC). 8. All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). 9. All high- strength bolting to be special inspected (Sec. 306, UBC). 10. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 12. Readily accessible access to roof mounted equipment is required. 13. Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 15. Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given in the soils report prior to final inspection (see attached procedure). 16. A statement from the roofing contractor verifying fire retardancy of roof will be required prior to final inspection (see attached procedure). All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 18. All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296 -4787, at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractors responsibility to have a set of plans approved by that agency on the Job site. 19. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 20. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8, shall be special inspected. 22. All wood to remain in placed concrete shall be treated wood. 23. All structural masonry shall be special inspected per U.B.C. Section 306 (a) 7. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. 25. A Certificate of Occupancy will be required for this permit. 1. Footings 2. Foundation 3. Slab /Slab Insulation 4. Shear Wall Nailing 5. Roof Sheathing Nailing 6. Masonry Chimney 7. Framing 8. Insulation 9. Suspended Ceiling X 10. Wall Board Fastening 11. 12. 13. 14. Fire Final 15. Planning Final 16. Public Works Final X 17. Building Final PLL N REVIEW COMMEN( a Plan Check No.: Project: CO 1. 1. No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. REQUIRED INSPECTIONS 2. Plumbing permit shall be obtained through the King County Health Department and plumbing will be, inspected by that agency, including all gas piping (296- 4722). Electrical permit shall be obtained through the Washington State Division of Labor and Industries, and all electrical work will be inspected by that agency (277- 7272). All mechanical work shall be under separate permit through the City of Tukwila. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 6. When special inspection is required, either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. 7. All structural concrete to be special inspected (Sec. 308, UBC). 8. All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). 9. All high- strength bolting to be special inspected (Sec. 306, UBC). 10. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 12. Readily accessible access to roof mounted equipment is required. 13. Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 15. Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given in the soils report prior to final inspection (see attached procedure). 16. A statement from the roofing contractor verifying fire retardancy of roof will be required prior to final inspection (see attached procedure). All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 18. All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296 -4787, at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractors responsibility to have a set of plans approved by that agency on the Job site. 19. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 20. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8, shall be special inspected. 22. All wood to remain in placed concrete shall be treated wood. 23. All structural masonry shall be special inspected per U.B.C. Section 306 (a) 7. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. 25. A Certificate of Occupancy will be required for this permit. City o Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Fire Department Review Control #91 -372 (513) September 10, 1991 Re: Ballard &Company - 625 Strander Blvd., #A & #B Dear Sir: Gary L. VanDusen, Mayor The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Maintain fire extinguisher coverage throughout. 2. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. (UFC 12.104b). Exit hardware and marking must meet the requirements of Uniform Fire Code Sections 12.104 & 10.402(a). Exit signs shall be installed at required exit doorways and where otherwise necessary to clearly indicate the direction of egress. Signs shall be of a contrasting color with the surrounding area and shall have letters not less than six inches high with a minimum letter width of 3/4 ". (UBC 3314) (UFC 12.108) 3. All required occupancy separations, area separation walls, and draft -stop partitions shall be maintained and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 10.401) Walls and ceilings of corridors serving an occupant load of 30 or more shall be not less than one -hour fire resistive construction. (UBC 3305(g)) (UFC 12.105(a)) .r City or Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Page number Gary L. VanDusen, Mayor. A1.1 interior wall covering materials shall, be . fire - resistive or shall be treated to be .; fire - resistive, so as to result in a flame - spread rating as required by UFC Appendix VI-C tables 42A and 42B. A certificate of the .flame .spread rating is required to be delivered to the Tukwila Fire Department. (UBC'4204) (UFC 10.401) CITY OF TUKWILA Department of Community Development - Building Division Phone: (206) 431 -3670 OCCUPANCY GROUP TYPE OF CONSTRUCTION LOCATION ON PROPERTY BUILDING HEIGHT /# OF STORIES FLOOR AREA 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 PROJECT: ALLAP -- j e. CO IAAP .t4 9 ADDRESS: ( ./----froA DEi. BLVD, OCCUPANT LOAD EXITING REQUIREMENTS DETAILED REQUIREMENTS OCCUPANCY TYPE OF CONSTRUCTION PART V, CHAPTER 23, U.B.C. W.S.E.C. CHAPTER 51-10, W.A.C. NOTES PREPARED BY: EX i NC REtAkINS O. K. Occ LP ' 1 •D (r)N E vT_ga,D DATE: