Loading...
HomeMy WebLinkAboutPermit 6824 - Silken Lady - Demising Wall and ADA Restroom6824 91-432 silken lady 16850 southcenter parkway Permit 6824 - Silken Lady TYPE OF CONST.: III_NUBC EDITION (year) 1988 SETBACKS: N-. S - E- W-- FIRE PROTECTION: ©Sprinklers D Detectors O N/A UTILITY PERMITS REQUIRED? DYes Q No Grouch Pubilc Works) ZONING: BAR /LAND USE CONDITIONS? D Yes (i0 No CONDITIONS (other than those noted on or attached to permit/plans) ZIP 98020 WA. ST. CONTRACTOR'S LICENSE # RMILLCI190L5 /1 6 -09 -92 PROPERTY OWNER Capital & Counties USA, Inc. PHONE 828 -4334 ADDRESS 101 California Street, Suite 2525, San Francisco, CA ZP 94111 CONTRACTOR R. Miller Inc. PHONE 583 -0238 ADDRESS 146 Third Avenue South, Edmonds, Wa ZIP 98020 WA. ST. CONTRACTOR'S LICENSE # RMILLCI190L5 EXP. DATE 6 -09 -92 ARCHITECT Peter Sbhroeder Architects PHONE 223 -0393 CITY OF TUKWILA Dept. of Community Development- Building 6300 Southcenter Boulevard, Tukwila WA (206) 431 -3670 ADDRESS T APPROVED FOR ISSUANCE BY: A k SIGNATURE:ri.;. PRINT NAME: o,,�- G� ( "3r /Pm This p Sh b ecome n ull and v oid' if the :work i ss u ance,; or if the wor is suspended or abandoriec CERTIFICATE OF OCCUPANCY NO. 1904 Third Avenuq, Suite 1005, Seattle, WA Division 98188 bUILUII U (POST WITH INSPECTION CARD AND PLANS IN A CONSPICUOUS LOCATION) FEES AMOUNT : RCPT# DATE 0. 3105> n0410491 111•0 :' .DESCRIP.TION BUILDING:PERM.IT FEE BUILD.ING.SURCHARGE >i PLAN CHECK NO.: BUILDING OFFICIAL 91 -432 •• PR • INFORMATI,O.N• SITE ADDRESS 16850 Southcenter Py SUITE # VALUE OF CONSTRUCTION - $ 16,000.00 ASSESSOR ACCOUNT # 262304- 9129 -06 PROJECT NAME/TENANT Silken Lady TYPE OF U New Building U Addition ti Tenant Improvement (commercial) U Demolition (building) U Grading/Fill WORK: D Rack Storage O Reroof ❑ Remodel (residential) ❑ Other: DESCRIBE WORK TO BE DONE: Build demising wall to separate space and consturct handicap restroom. USE" } Retail>••:: /B. 2 SQUARE FEET 1 380 FLOOR OCC. LOAD 38 SQUARE FEET OCC. SQUARE OCC. LOAD FEET LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD TOTAL SQUARE FEET 1,380 1,380 TOTAL OCC LOAD 38 38 DATE: /0 v)(t_ y/ - ten► I hereby certify that I have read and exa this permit and know the same to be true and correct. All provisions of lay and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. DATE: / o 9- )l I 98101 COMPANY: fj'. t�- not commenced within 180 days from the date f or a period of :180 days from the last inspecti DATE ISSUED: PERMIT NO. CONTACTED Lt-Yln l DATE READY DATE NOTIFIED 2nd NOTIFICATION Icy-act-9i BY: BY: (init.) BY: (init.) PERMIT EXPIRES AMOUNT OWING 1 -- 1,,* . S 3RD NOTIFICATION PLAN CHECK NUMBER PROJECT NAME SITE ADDRESS INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". BUILDING SQUARE FOOTAGE/OCCUPANCY INFORMATION (to be filled out by Plan Checker) SQUARE FEET SQUARE OCC. SQUARE OCC. FEET LOAD FEET LOAD i SQUARE FEET OCC. LOAD . OCC. LOAD SQUARE OCC. FEET LOAD TOTAL SQUARE FEET DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. DEPARTME . FIRE LANNING O PUBLIC WORKS O OTHER ,BUILDING - 10- 1 l initial review INIT: AP. ROV ED: O 04 c i f FL (ROUTED) IO /z4/ / R. Id k INIT: ‘bi HMI INI BUILDING - final review REVIEW COMPLETED BUILDING( 'BRMIT APPLICATION TRACKING 31k -can Lob CONSULTANT: Date Sent - ZONING: REFERENCE FILE NOS.: MINIMUM SETBACKS: N- TYPE OF CONSTRUCTION: •UIR.EM E FIRE DEPT. LETTER DA : ( 41 SUITE NO. Date Aeproved - FIRE PROTECTION: ISpri kte s fl Detectors (7 N/A INSPECTOR: .r UTILITY PERMITS REQUIRED? 111=3118`Er . PUBLIC WORKS LETTER DATED: BAR/LAND USE CONDITIONS? (! Yes (1 No UBC EDITION (year): 1 168 TOTAL OCC. LOAD 08/17 PROPERTY OWNER C- /9Jo/'r'.t / V C o c >.v7 -i cs U.54. - 7v ; r. Sca.•r S:4 S" .S/gn•• pr,4w• c.. C-p /',: 1PHONE PHONE f.7 S,_t/ .33V ZIP9 / / / ADDRESS CA /P. CONTRACTOR . ADDRESS / y4 rot, r v•� .5- k d „ A. , ..,re s ,e/c..„ mss 4 q BU.1. a EXP. DATE 6-q-72 _ PHONE 223 ZIP 0373 WA. ST. CONTRACTOR'S LICE # R1v,, ARCHITECT r4'T�vt Sr 1 r ne ct'a i3er : re c'rs ADDRESS / q a 4 3. /l a v t ... -5c.. / r c ) c7 0 } t ,, ,.a. F Ly ya 4 %. `I 676 ) zIP vVVV VVU II IVGIILUI LJUUIC,VCUUI I U/%VIIIIGI VIII, 17U I UU (206) 431 -3670 .. DESCRIPTION AMOUNT RCPT # DATE BUILDING. PERMIT FEE : I •71. 00 PLAN CHECK - 7 '(..D NUMBER q —� iLc. D ' C MP T LY:.. PLAN CHECK•FEE 1( c 13jt (o 10 —ct ) BUILDING SURCHARGE{ OTHER TOTAL – SITE ADDRESS SUITE # 1 6 b 50 5 l' -e/vr l > t.4- Air - VALUE OF CONSTRUCTION - $ ii / G 000. C» PROJECT NAME/TENANT - 5iOf ePt/ L -/9dx ASSESSOR ACCOUNT # 45a3 oI/9/2,, 1 0 (commercial) U Demolition (building) 0 Other TYPE OF 0 New Building U Addition kg Tenant Improvement WORK: 0 Rack Storage 0 Reroof 0 Remodeijresidential) DESCRIBE WORK TO BE DONE: /3u /c( 10<'6niS.w, ct.,A-1/ 7o ;<'ficriaft Ste/ ?ct. r4,41V%- /f/'n li _Ye S7'r" BUILDING USE (office, warehouse, etc.) /ti .E: 7`'4 / / NATURE OF BUSINESS: WILL THERE BE A CHANGE IN USE? ® No 0 Yes If Yes, new building requirements may need to be met. Please explain: SQUARE FOOTAGE - Building: Tenant Space: 1/3 ft.. v Area of Construction: ,1 17G a WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? No 0 Yes IF YES, EXPLAIN: CITY OF TUKWILA Department of Community Development - Building Division tQr)n t- • `n..ihn�nfnr pn.Inu..r.J T..L.ull.. IA /A Abi b0 I:HEREBY .;CERTIFY. THAT I HAVE READ;AND :EXAMINED THIS APPLICATION :AND KNOW THE SAME, BE :TRUE AND .CORRECT, AND I .AM AUTHORIZED .TO APPLY FOR THIS BUILDING OWNER OR AUTHORIZED AGENT CONTACT PERSON DATE APPLICATION ACCEPTED SIGNATURE DATE /a- /'a - - 9/ ��- a�„,r../: � cr► -�..� -arc PRINT NAME ADDRESS Pf G Th• 4-vt'• -S Ic -to BUlLDIN PERMIT APPLICATION APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations, The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431 -3670. DATE APPLICATION EXPIRES PHONE 55,2_ ` 0 2.? Fs' CITY/ZIP 98,6 z. o PHONE S`63_ 0221 ( 03/1019i COMMERCIAL NEW COMMERCIAL BUILDINGS /ADDITIONS Completed building permit application (one for each structure) Assessor Account Number :Two sets (2) of the following: Specifications Structural calculations stamped by a engineer Soils report stamped by a Washington State licensed engineer survey Completed utility permit application n Six (6 sets of civil drawings NOTE: See utility permit application and checklist for specific utility.: submittal; requirements. RACK STORAGE Completed building permit application Assessor Account. Number Two, (2) sets of plans, which Include : Energy calculations stamped by a Washington State licensed engineer or architect Legal description .. Working drawings, stamped by a Washington State licensed:: architect; which include • Site plan • Architectural drawings • drawings • Mechanical drawings • Elevations • • Civil drawings,: .. • Landscape plan Building floor plan showing.:; ; • Entire space where racks will be located .: • Exit doors • Dimensions of all aisles Tenant space floor plan showing rack storage layout, aisles and exits. NOTE: Include dimensions of racks (height, width and length), aisles and exit ways on plan. Structural calculations stamped by a Washington State licensed engineer (rack storage 8'. and over). RESIDENTIAL NEW SINGLE•FAMILY DWELLINGS/ADDITIONS Completed building permit application (one for each structure) Legal description Cn Assessor Account Number Two sots (2) of working drawings; Which include: • Site plan.` plan, show closest hydrant location • Foundation plan Include access to building; showing • Floor plan • and length of access.) •. Roof plan elevations (all . views Building cross-section: • Structural framing plans Washington State Energy Code data' Completed building permit application (one for each structure Assessor Account Number Two (2) seta of working drawings, which include • Site plan. • ". • Foundation plan ••Floor.plan Roof. plan • •:Building elevations (all views) !:Building cross section • •:Structural framing plans NOTE: If any utility work Is to be done provide utility permit application and plans must be submitted. ; REROOFS;.• Completed building permit application.(one for each structure n Assessor Account Number • - Narrative describing existing root; material being removed, and - material being installed. NOTE: A certification letter Is required prior to final Inspection and sign; ; • off of the permit • Completed utility permit application Six (6) sets of site plans showing utilities '. NOTE :. Building site plan and utility silo plan may be combined See utility permit application and checklist for specific submittal requirements. Additional topographical and soils information may be required if unique site conditions. SUE64ITTAL CHECKLIST COMMERCIAL' TENANT: IMPROVEM E Completed building permit application tenant) Assessor Account Number. Two (2) sets of construction plans which include: Sit plan • Locati on.of'tenant,space r.i Existing and proposed parking ndscapo; plan (if .:applicable, i e , change •of.use Overall building plan • Tenant location • Use of adjacent (common wall) tenant • Overall dimensions of building or square footage :? oor.pian of proposed tenant space Tenant space plan witk use of each room label) Exit doors,: egress' patterns.:' •' New walls, existing wall, and walls to be demolish • Constriction details C • ross sections showing wall construction and method of . attachment for floor and ceiling Structural calculations stamped by a Washington: State :licensed engtneermay be' required if structural work is to be done (2 sets);: • .NOTE I 'll any utility work is to be done,: submit separate. uulrry permit application and plans REROOF Completed building permit application (one for each structure Assessor. Account Number....::;' ri Narrative describing existing roof, material. being removed, and ' :material being installed NOTE: A certification letter is required prior to final Inspection and sign off of the permit • ANTENNA/SATELLITE DISHES Completed building permit application' • n Assessor. Account Number Two (2) sets of plans, which include;:: Site Plan (showing building . and location of antenna/satellite dish) in Details :antenna /satellite dish and method of attachment n Structural calculauons•stamped . by a Washington State licensed engineer:may be required RESIDENTIAL REMODELS .:' Project: 1 t acan Type ot Inspection ; A` ) Tddress: %{ I u k Date Called; special Instruct ons; 7Ckc n 5,1 :,erN L (j Date Wanted: � _c:::, �07 m. p.m. R eques t er: -- I� I�YI �c.�lrll "� Phone No,: ci q, _s 0102. C INS ECTION CbRb 1 Retain a copy with permit INSPECTI6N NO: CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 COMMENTS: Approved per applicable codes. 0 Corrections required prior to approval. $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (206) 431 -3670 COMMENTS: _.... ___.a._......_.. ..... .. ........__.:._..._.._....: ype o ns.: `n: '1� - -. • v. 1 PI 4.€ I P (AA, vh 61 r•3(', t t ,, .... - r ' Specie nstructlons: L n.)'t O � ',� Stt k:�n Lu N1(1r -f) V4>iI(rt by (� . -„ , V A C.. r na - t' ■ L. Phone No.: O i ce C riQ -- ` 4t(n(� r<0( e,ert,./�"'t ? -- N 01 rs -Lr.Sr Ic_ en LS' l: r,OM0nt ). / f . /1 -671.- el, A - r - i 4 IL+Tn n. j n•c-N it-. Al n t) i r ., 5 t t c -`. J . Sr},Itc -.. T ,A,:+' C. • . it 5 (, 61 !k - p r 441 T l' - VC A-4 e tw v,14•c.- ti /• ) i.j t 6-We 14 tr'1 C. 4-1 A- A--i"Tx (7 L_ ilk his--1 f=-t.4 LA-. t-t �∎. 1 f "i Kr i )-Y 2 c-t 6.4 SP 6 t� t' • . . • ro ec : ype o ns.: `n: '1� - -. '.cress: . • • - .. late a es: _J .. �-) Specie nstructlons: L n.)'t O � ',� Stt k:�n Lu N1(1r -f) V4>iI(rt by (� Date anted: - (0 C (am),m, Requester: 'Torn 5mi h Phone No.: O i ce C riQ -- ` 4t(n(� r<0( 0. C INSPECTION RECORD 0„ Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188c: _.) Receipt ❑ Approved per applicable codes. I Inspector: - r (/ % L 3 (A ,@ 1 -1 PERM' (206) 431 -3670 Corrections required prior to approval. Date: 3 2.6 97- $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at ((� 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: COMMENTS: ' yp e o nspect on; Fi ran,\ Address: y LP , t H-ry.en fa i 1 a rtria, r.1 Pt I t . € I P t-LA v■ d 1 NIC, n/A't- - 2 gc I- VE W vol C. S t 7'‘,... (3u 17 jj� rt-' � , 0 1 r-r—t t.S 'lr1... ►' a Lo C m'ta 4 3) _"t' .. ___ L - A laP✓1 - R -c Data !t_ A,.JO tc -'E' ! rJ5t T / / /// S. t h114- 'r i-&' . c� C d Vela- Q Us k G. €T A- R-c. t41TEC -T M 0 rya Wes.- o 1L( &AA 1 `i �l Cs. qv' (<- "14Q(l.- 1 . CZ --- hte1( 1\ 1 . 1 *II Lei N Se e-r at. ( . 'roe \ j cr�r,l yp e o nspect on; Fi ran,\ Address: y LP , t H-ry.en fa i Date Called: 3 _ , D5✓ cb Special Instr ons: .J 5c)ac-*i 11'2k1" 4-o St ken dj Ve r • (i�rl bu �=i r� Date Wanted: 3 - &C9 - ci t z am. m. Requester : _I —C)rn 5m'it Phone No,: � �a^ � � � i to ( u n r Receipt , 1467 INSPECTION RECORD C Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Or 0 Approved per applicable codes. Inspector: Corrections required prior to approval. 372.6,fez $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Date: (206) 431 -3670 d j •e , Li A A.A Type oflnspe 'i, di u, f 0 `5 C Kvj Date Called: Z 13_ 9z / Special Ins ruc ons: ,� 1 () t A4‘raei ak 1D DD. Date Wanted: Requester: /1 ' Phone No.: =_ — ` .i CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ❑ Approved per applicable codes. COMMENTS: l INSPECTION RECORD Retain a copy with permit Corrections required prior to approval. A ( S, S /ei 4 k 04 /4 74.4 j / / /�� r'h�c, I oi&3 Pf:RMR , (206) 43 -33670 nspector: Ala ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Project: ./. 1 Type of Inspectlo : s� ?so C o 0 S r. 1 / L()i -t eCa e•: / n� //� Sp e al Instructions: Date Wanted: /" .� f % �— am. p.m. Requester: / Phone No.: 3 , 0 - ,)-3X 2 Inspect° C INSPECTION RECORD C Retain a copy with permit PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: G' # rte - * c -\V Date: $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. „a__- )4/L (206) 431 -3B70 ❑ Corrections required prior to approval. Receipt No.: 7 Date: • roe. 1 t Afrvry ype o nspe. on:r— r sra, TY idpre q co 5. EA- i Date Called: ,K.....o 6pellrnstructions: . Date Wanted: 1 - -- )z-9 1 el p .m. Requester: a V ...... Phone _ 0 , t_giri,a:._‘. 4 CANISI ,;t7" ..1377.• , • 1 SU INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: nspector: 0 Corrections required prior to approval. atei ...ea 9 0 $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. • I Receipt No.: Date: roe V p.�ti a (ad , Type of In 10.9 I Addrp Q G 6 _6 C . r 4 / / J t' Date Called: �� /,/ — --7 Sped al Instructions: Date Wanted: II -- Requester; Phone No.:_ 7 , Ip INSPECTION RECORD 0 Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ,Approved per applicable codes. COMMENTS: ' 4 J 7. O c,G4 _ 2 y ,c,./4- i Ah/ ),7 /e_4-0 ti O Corrections required prior to approval. nspec O $30.00 REINSPECTION FE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Date: r• R R 0. (206) 431'8670 roe : 1 k _ nom ype o nspect on: .,ress : /eag e 5.C, /04W te ale •: // --- 76 - q/ Special Instructions: / Date Wanted; I - 2 9 m. / i am. .m. Requester: Phone No.: INSPECTION RECORD 0 'Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 0 Approved per applicable codes. IR Corrections required prior to approval. COMMENTS: (.",'7 /$.4' 1 21) l > f7 ' . S ,'e - c e c -e. G-' Inspector: ❑ x '.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. wept No.: Date: Date: • COMMENTS: t esAl \ S--k IN ‘N C t ai A ts 0 G. v■i 6 c-4- 1-... CA or- c ------- .a k 0 -,:_:-.7 1 s A.4 e tt- t-) Ct..=. . g....e.h..c,,A - 1 NA vsl (L tc__ IA PcZ S-rr--r- IS t."- wki-L 6 sate a e.: / .--, 4,0„, - fr. e l t t V1- ' -. -t. o e • _ ..... Date Want* _ 0 - 9 ) am. P.m. Requester: i xaies_4Adt 1 , •-- 1 S - , f ) il.AW. A (.1 Of - rlA c.r..- - /N-41- ‘AVA C. - € V AT c." Nr\ SPA C.._ • 1761;R: i r_eit...... iype o nspe. o : / AL_A_AANA Address: i(AO 1 ) I ; sate a e.: / .--, 4,0„, - fr. spedal Instruct ons; O f M•Y-4-A'-11 fr2077(11•:Pri c e ifooks _ ..... Date Want* _ 0 - 9 ) am. P.m. Requester: i xaies_4Adt 1 , phone No.: CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit (206) 431-370 0 Corrections required prior to approval. c---, [inspector: Date: 0 $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 10 -30 - gc;?735; 70 ,7 7-171 : ' : r,';,.r :3" T,- -^�.nlmr, " lr,'s,Llt,o P"MI` s x� ■•• City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575-4404 Project Name Address Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: TU1WILA FIRE DEPARTMENT FINAL APPROVAL FORM DY f LA i� CA' 1 , zi.o. Retain current inspection schedule Li Needs shift inspection Approved without correction notice V Approved with correction notice issued ``■ , Gary L. VanDusen, Mayor Control No. Permit No. S'Z Suite # /!4 7 A Authori ze Signature Date FINALAPP.FRM T.F.D. Form F.P. 85 CITY OF TUKWILA 6200 SOUTIICE'NTER BOULEVARD, TUKWILA, WASHINGTON 98188 Plan Check #91 -432: Silken Lady 16850 Southcenter Py PHONE II (2061 433.1800 THE FOLLOWING COMMENTS APPLY TO AND BECOME THE APPROVED PLANS UNDER TUKWILA BUILDING PERMIT NUMBER 0 1. No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296- 4732). 3. Electrical permit shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (872- 6363). 4. All mechanical work shall be under separate permit through the City of Tukwila. 5. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 6. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 7. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 8. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1991 Edition), and Washington State Regulations for Barrier Free Facility (1989 Edition). 9. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. Cary L, VatDusen, Mayor "X" REQUIRED INSPECTIONS PHONE DAM APPROVED INSPECT. INITIALS DATE(S) CORRECTION NOTICE ISSUED 1 Footings 431 -3670 2 Foundation 431 -3670 3 Slab and/or Slab Insulation 431 -3670 4 Shear Wall Nailing 431 -3670 5 Roof Sheathing Nailing 431 -3670 6 Masonry Chimney 431 -3670 R 7 Framing 431 -3670 8 Insulation 431 -3670 9 Suspended Ceiling 431 -3670 X 10 Wall Board Fastening 431 -3670 11 12 13 R 14 FIRE FINAL Insp: 575 -4407 15 PLANNING FINAL 431 -3670 16 PUBLIC WORKS FINAL 431 -3670 X 17 BUILDING FINAL 431 -3670 SITE ADDRESS: 16850 Southcenter Py CITY OF TUKWILA Department of Community Development - Permit Center 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 BUILDIt PERMIT INSPECTION RECORD (Post with Building Permit In conspicuous place) SUITE NO.: BUILDING (A(D PERMIT NO. DATE ISSUED: PROJECT: Silken Lady CALL FOR INSPECTIONS AT LEAST 24 HOURS IN ADVANCE (INSPECTOR COMMENT SECTION ON REVERSE, INSPECTION PROCEDURES AND REQUIREMENTS All approved plans and permits shall be maintained available on the site in the same location. 1. FOOTING - When survey stakes and forms are set and rebar is tied in place. 2. FOUNDATION - When forms and rebar are in place. 3. SLAB - If structural slab or if underslab insulation is required. 4. SHEARWALL NAILING - Prior to cover. 5. ROOF SHEATHING NAILING - Prior to cover. 6. MASONRY CHIMNEY - Approximately midpoint. 7. FRAMING - After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping is in place. 8. INSULATION - After framing approval, but before installation of wallboard. Baffles must be installed to keep attic ventilation points clear. 9. SUSPENDED CEILING - Fasten diffusers, lights and seismic bracing. 10. WALL BOARD FASTENING - Prior to taping (see UBC Chap. 47 and Table 47G). 11. 12. 13. 14. FINAL FIRE INSPECTION - Contact Fire Department for their requirements. 15. FINAL PLANNING INSPECTION - Contact Planning Department for their requirements. 16. FINAL PUBLIC WORKS INSPECTION - Contact Public Works Department for their requirements. 17. FINAL BUILDING INSPECTION - When all work, corrections, reports and other inspections are complete. OTHER AGENCIES: Plumbing (including gas piping) — King County Health Department — 296 -4732 Electrical — Washington State Department of Labor and Industries --- 277 -7272 A preconstruction meeting with the Building Inspector may be scheduled prior to starting the job by contacting the Department of Community Development, Building Division at 431 -3670. Although not required, a meeting of this type can often eliminate problems, delays and misunderstandings as the project progresses. 09 /14/90 Plan Check No.: U U -432 2 REQUIRED INSPECTIONS SAN REVIEW COMMENTS 0 0 Project: 61i s i G No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296- 4722). Electrical permit shall be obtained through the Washington State Division of Labor and Industries, and all electrical work will be Inspected by that agency (277 - 7272). All mechanical work shall be under separate permit through the City of Tukwila. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 6. When special inspection is required, either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. 7. All structural concrete to be special Inspected (Sec. 306, UBC). 8. All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). All high- strength bolting to be special inspected (Sec. 306, UBC). Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 12. Readily accessible access to roof mounted equipment is required. 13. Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. 14. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 15. Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given in the soils report prior to final inspection (see attached procedure). 16. A statement from the roofing contractor verifying fire retardancy of roof will be required prior to final inspection (see attached procedure). All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 18. All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296 -4787, at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractors responsibility to have a set of plans approved by that agency on the Job site. 19. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for Inspection at the factory. 20. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8, shall be special inspected. 22. All wood to remain in placed concrete shall be treated wood. 23. All structural masonry shall be special inspected per U.B.C. Section 306 (a) 7. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. A Certificate of Occupancy will be required for this permit. 1. Footings 2. Foundation 3. Slab /Slab Insulation 4. Shear Wall Nailing 5. Roof Sheathing Nailing 6. Masonry Chimney X 7. Framing 8. Insulation 9. Suspended Ceiling X 10. Wall Board Fastening 11. 12. 13. X 14. Fire Final 15. Planning Final 16. Public Works Final 17. Building Final Plan Check No.: U U -432 2 REQUIRED INSPECTIONS SAN REVIEW COMMENTS 0 0 Project: 61i s i G No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296- 4722). Electrical permit shall be obtained through the Washington State Division of Labor and Industries, and all electrical work will be Inspected by that agency (277 - 7272). All mechanical work shall be under separate permit through the City of Tukwila. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 6. When special inspection is required, either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. 7. All structural concrete to be special Inspected (Sec. 306, UBC). 8. All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). All high- strength bolting to be special inspected (Sec. 306, UBC). Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 12. Readily accessible access to roof mounted equipment is required. 13. Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. 14. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 15. Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given in the soils report prior to final inspection (see attached procedure). 16. A statement from the roofing contractor verifying fire retardancy of roof will be required prior to final inspection (see attached procedure). All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 18. All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296 -4787, at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractors responsibility to have a set of plans approved by that agency on the Job site. 19. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for Inspection at the factory. 20. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8, shall be special inspected. 22. All wood to remain in placed concrete shall be treated wood. 23. All structural masonry shall be special inspected per U.B.C. Section 306 (a) 7. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. A Certificate of Occupancy will be required for this permit. Fire Department Review Control #91 -432 Re: Silken Lady - 16850 Southcenter Parkway Dear Sir: City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Gary L. VanDusen, Mayor October 25, 1991 The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10 B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) (UFC 10 -1 (3 -1)) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher," with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC 10.301) 2. Exit hardware and marking must meet the requirements of Uniform Fire Code Sections 12.104 & 10.402(a). Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. (UFC 12.104b) Exit signs shall be installed at required exit doorways and where otherwise necessary to clearly indicate the direction of egress. Signs shall be of a contrasting color with the surrounding area and shall have letters not less than six inches high with a minimum letter width of 3/4 ". (UBC 3314) (UFC 12.108) 3. All modifications to sprinkler systems shall have the Page number 2 This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 6. Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers shall contrast with their background. (UFC 10.208) FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Yours truly, City of Tukwila written approval of the Washington Survey & Rating Bureau, Factory Mutual Engineering or Industrial Risk Insurers, then by the Fire Department. No sprinkler work shall commence without approved drawings. (City Ordinance #1528) (NFPA 13, 1 -9.1) (UFC 10.307) Contact the Tukwila Fire Department, Fire Prevention Bureau to witness all required inspections and tests. (NFPA 13, 1-10.2) (UFC 10.305(b)) 4. Each circuit breaker shall be legibly marked to indicate it's purpose. (NEC 110 -22) 5. The entrance to your store shall be posted with "No Smoking" signs. "No Smoking" signs shall be posted conspicuously throughout the store. The Tukwila Fire Prevention Bureau • cc: T.F.D. file ncd Gary L. VanDusen, Mayor * D.C.D - BUILDING DIVISION * PLAN REVIEW * PLAN REVIEW NO : 91 -432 PROJECT NAME: SILKEN LADY, TENANT IMPROVEMENT DATE: October 24, 1991 OCCUPANCY GROUP: N/C B -2, RETAIL TYPE OF CONSTRUCTION: N /C, PROPOSED CONSTRUCTION = NON COMB. LOCATION ON PROPERTY: N /C' EXISTING BLDG. IN COMPLIANCE. BUILDING HEIGHT / NO OF STORIES: ONE FLOOR AREA: TENANT SPACE = 1380 SF OCCUPANCY LOAD: EXITING REOUIREMENTS: OCCUPANT LOAD < 50 THFRE ONE EXIT O.K., TWO EXITS PROVIDED FROM SPACE. WIDTH O.K. SEPARATION O.K. EXITING FOR THIS TENANT SPACE AND FOR THE ADJACENT TENANT SPACE CREATED BY THIS WORK, REMAINS IN ACCORDANCE WITH CHAPTER 33. DETAILED REOUIREMENTS OCCUPANCY: O.K. TYPE OF CONSTRUCTION: O.K. CHAPTER 23, U.B.C.: N/A W.S.E.C.: N/C BARRIER FREE REQUIREMENTS: O.K. RETAIL FLOOR 1100/30 = 37 OFFICE 1 TOTAL 38 OCCUPANTS floor planS EPARATE PERMIT AND APPROVAL REQUIRED G DIVISION LEGAL DESCRIPTION Parcels Ill and IV of Boundary Line Recording No. 7904180861, being a i under Recording No. 7710130634, Re of that portion of the Southeast 1/4 Township 23 North, Range 4 East, ■1 described as follows: Beginning at the monumented intersec Parkway (57th Avenue south) and St thence South 89 °45'58" East along th Strander Boulevard, a distance of 32 parallel with the monumented East li 30.00 feet to an intersection with tt Boulevard, and the true point of bec thence continuing South 0 °25'58" Eas South 89 °45'58" East parallel with se distance of 350.00 feet to the monu thence South 0 °25'58" East along sai to the monumented Southeast corner 89 °43'19" West along the the monumi distance of 626.81 feet to the East thence North 0 °57'48" West along sal feet to a point of curve; a radius of 91 °11'50 ", a distance of 79.58 feet Boulevard; thence South 89 °45'58" El of 237.72 feet to the true point of The aforementioned monumentat n e L.I.D. No. 13, Contract No. 2 SEPARATE .�t ; PERMIT AND '�'`µ' �` NA' APPROVAL , "'° ' t ` REQUIRED site plan BOIL DIVISION LEGAL DESCRIPTION Parcels Ill and IV of Boundary Line adjustment No. BLA -3 -79 recorded under Recording No. 7904180861, being a revision of Short Plat No. 77 -51 recorded under Recording No. 7710130634, Records of King County, being a short plat of that portion of the Southeast 1/4 of the Northwest 1/4 of Section 26, Township 23 North, Range 4 East, W.M., in King County, Washington, described as follows: Beginning at the monumented intersection of the centerlines of Southcenter Parkway (57th Avenue south) and Strander Boulevard, (South 164th Street; thence South 89 °45'58" East along the monumented centerline of said Strander Boulevard, a distance of 325.05 feet; thence South 0 °25'58" East parallel with the monumented East line of said subdivision a distance of 30.00 feet to an intersection with the South margin of said Strander Boulevard, and the true point of beginning of the herein described tract; thence continuing South 0 °25'58" East, a distance of 200.00 feet; thence South 89 °45'58" East parallel with said centerline of Strander Boulevard, a distance of 350.00 feet to the monumented East line of said subdivision; thence South 0 °25'58" East along said East line, a distance of 1093.20 feet to the monumented Southeast corner of said subdivision; thence North 89 °43'19" West along the the monumented South line of said subdivision, a distance of 626.81 feet to the East margin of said Southcenter Parkway; thence North 0 °57'48" West along said East margin, a distance of 1241.85 feet to a point of curve; a radius of 50.00 feet through a central angle of 91 °11'50 ", a distance of 79.58 feet to the South margin of said Strander Boulevard; thence South 89 °45'58" East along said South margin, a distance of 237.72 feet to the true point of beginning; The aforementioned monumentati n established t 'I ttie Cry 'pf Tukwila under L.I.D. No. 13, Contract No. 2 68, Sht. 1 of 19, Street PTan and Profile. I understand thatAe�P•,gn..Check approvals are 5 urril biulw cnt1•i ut.411uvd1_t►} _. . p lans does not a uth o r iz e the vieration :ci any ' . �, , 1010..:. .1' 6d4p#'pa,c�'O .ordiniai :...�cbi r.I5f• ontrdretortto•, _10_.10, 1 'copy' of approy>;.... . , . *: , i , ' - i 10 P us 1 R, J • 1010 � ; .. � � - 1 ,, . � , -`1 - i' ;.. • I • •z: • : .non•ratail A spaca ?:,co t1 10.. IA. v• ' • 10,10 !... . • •• - ••••,• ,,,• T 10 ••10••. •10 •••• • • ••• 1•.,; 1010 ••I ��'�( {�. _ 1 - /. • • • • Vii l. 1101 ..7 R J ••••• ; .... •, :•;:: Permit No. I 1 •, T • • • ♦•• • 8. prcpos • 2d w, .•-... ••• • • ' • - • • • _ • • •••1010r .� J rv. • •_ • j state•. plan . . � _ i " _'•_'- •.,1.. •..t.. • .�• �t , • r I , ♦ • . Lr , . • "" • r • ••• :1 •.• • 10 10 • :r' ., . , 1 ' J : • • • P• •• • • . • • ♦ •. . • • • • • ••'• ••• .••1 1. • • • ` ••„•'1010, • • 1 • • • .V. • 1' t. .3 • • is RECEIVED CITY OF TUKWILA OCT 101991 PERMIT CENTER HANDICAP BATHROOM (same or opposite hand may apply) CITY OF TUKWILA APPROVED OCT 2 $ 1991 BI.IILD G DIVISION GENERAL NOTES 1. General Contractor shall verify all exist commencing work. 2. Do riot scale drawings. Verify all dimen work. Notify Architect concerning ques 3. Contractor shall be responsible for provi materials in accordance with all applical building and fire codes as required. 4. Contractor shall visit job site and verify notify Architect or Engineer of any disc with work. 5. B.S. indicates "building standard" as pro and /or specified in building contract doc 6. A.F.F. indicates "above finish - floor." 7. Contractor to obtain all permits and apl 8. Dimensions are to face of stud, face of centerline of column, unless otherwise n 9. Where 1 hour fire rating is required use metal trim at all corners and edgings. nailed). 10. All gypsum wall board in moisture prone 5/8" type "X" Green label. (restroom) 11. Surface materials which are part of the shall be installed prior to final inspectic 12. Mineral fiber insulation shall be installe a pluming pipe or duct penetrates a flo where such unit passes through the plan assembly from within a wall. The insul point 12" beyond the pipe or duct. 13. Other tested assemblies may be used if the Architect. 14. Provide draft stops, fireblocking and fir .15. Draft stops shall be at ceiling space as shall not exceed 3000 sq. ft. nor have exceeding 60'. 5/8" type "X" Gyp BD per UBC requirements. 16. All glazing shall be safety glass in ares Building Code, and all other applicable 17. All work shall comply with the Uniform applicable codes. 18. Provide smoke detectors as shown or as 19. All interior partitions not to underside laterally braced as required by UBC. 20. All suspended ceiling panels are to be 1 by UBC. 21. Sign at exit door to read "This Door to Business Hours," as per UBC 3304(c) Ex STRUCTURAL NOTES FOR STEEL STUDS All steel studs to be US Gypsum. 3 5/ O.C. (UNLESS pTHERW 16s 1JdTED Section Properties of stud Sx -x = .125 in.3 Ix -x = .243 in.4 Connection 1. Power driven fastener to cone recommendation. 2. Connection between stud to diagl shall be 2 - 11 8 sheet metal per stud per connection. 3. Connection to wood roof structure drilling screw with min. penetrat APPROVED OCT 28 1901 RIiILD G DIVISION GENERAL NOTES 1. General Contractor shall verify all existing conditions prior to commencing work. 2. Do riot scale drawings. Verify all dimensions before proceeding with work. Notify Architect concerning questions, changes, or omissions. 3. Contractor shall be responsible for providing all work and materials in accordance with all applicable city, county, and local building and fire codes as required. 4. Contractor shall visit job site and verify all field dimensions and notify Architect or Engineer of any discrepancies before preceding with work. 5. B.S. indicates "building standard" as provided by Landlord drawn and /or specified in building contract documents. 6. A.F.F. indicates "above finish - floor." 7. Contractor to obtain all permits and approvals. 8. Dimensions are to face of stud, face of concrete or masonry, centerline of column, unless otherwise noted. 9. Where 1 hour fire rating is required use 5/8" G.W.B. type X. Use metal trim at all corners and edgings. Board to be screwed (not nailed). 10. All gypsum wall board in moisture prone areas to be waterproof. 5/8" type "X" Green label. (restroom) 11. Surface materials which are part of the floor - ceiling -wall assembly shall be installed prior to final inspection of the buildings. 12. Mineral fiber insulation shall be installed in joist spaces whenever a pluming pipe or duct penetrates a floor- ceiling sound assembly or where such unit passes through the plans of the floor- ceiling assembly from within a wall. The insulation shall be installed to a point 12" beyond the pipe or duct. 13. Other tested assemblies may be used if submitted and approved by the Architect. 14. Provide draft stops, fireblocking and firestops as required by UBC. 15. Draft stops shall be at ceiling space as required. Draft stops shall not exceed 3000 sq. ft. nor have a horizontal dimension exceeding 60'. 5/8" type "X" Gyp BD on Wd. stops to be used. As per UBC requirements. 16. All glazing shall be safety glass in areas required by Uniform Building Code, and all other applicable codes. 17. All work shall comply with the Uniform Building Code, and all other applicable codes. 18. Provide smoke detectors as shown or as required. 19. All interior partitions not to underside of structure are to be laterally braced as required by UBC. 20. All suspended ceiling panels are to be laterally braced as required by UBC. 21. Sign at exit door to read "This Door to Remain Unlocked During Business Hours," as per UBC 3304(c) Excp.1. STRUCTURAL NOTES FOR STEEL STUDS All steel studs to be US Gypsum. 3 5/8" 25 GA studs or equal ® 24" O.C. (UNt ess omeRwtC s NoTED) Section Properties of stud Sx -x = .125 in.3 Ix -x = .243 in.4 Connection 1. Power driven fastener to concrete slab per manufacturer's recommendation. 2. Connection between stud to diagonal and stud to runner track shall be 2 - 4 8 sheet metal self drilling screws or equal per stud per connection. 3. Connection to wood roof structure shall be with 2 - 8 GA self drilling screw with min. penetration of 1" into wood structure • RECEIVED CITY OF TUKWILA OCT 1 01991 PERMIT CENTER