Permit D01-020 - DR SIMMONS - WALLS AND ADA RESTROOM
D01-020 Dr. Jim Simmons 411 Strander B1 City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila. Washin,:; ton 98188 Parcel No: Address: Suite No: Location: Category: Type: Zoning: Const Type: Gas /Elec.: Units: Setbacks: Water: Wetlands: Contractor License No: OLYMPCI1360S OCCUPANT DR. JIM SIMMONS 411 STRANDER BL; STE. 202, TUKWILA, WA 98188 MEDICAL CENTERS C/0 NEWCASTLE REAL ESTATE, 15642 SE 24TH ST, TOM ESTEP 220 27 AV, SEATTLE, WA 98112 OLYMPUS CONSTRUCTION INC PO BOX 50082, BELLEVUE WA 98015 ***************************************************** * * * * * * * * * ** * * * * * * * * * * * * * * * * * * ** Permit Description: ADD NEW WALLS AND ADA RESTROOM. BUILD OUT NEW EYE OFFICE INTO EXISTING SPACE ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** OWNER CONTACT CONTRACTOR ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ ***** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES. APPLICANT IS PROCEEDING AT THEIR OWN RISK. AOFF DEVPERM TUC 022320 -0052 411 STRANDER BL Occupancy: UBC: 001 Fire Protection: North: .0 South: .0 East: .0 West: N/A Sewer: N/A Slopes: N Streams: Construction Valuation: $ PUBLIC WORKS PERMITS: *(Water Curb Cut /Access /Sidewalk /CSS: Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversized Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Permit Center Authorized Signat ry DEVELOPMENT PERMIT 6Z 50,000.00 Meter Permits Listed Separate) Eng. Appr: N N No: Size(in): .00 N N Start Time: End Time: N Cut: Fill: N N Start Time: End Time: N No: N Private: N Public: N N N N Private: N Public: N 1,066.69 * * * * * * * * * ** ** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit No: Status: Issued: Expires: Phone: (206) 431 -3670 D01 -020 ISSUED 02/13/2001 08/12/2001 OFFICE 1997 AUTO FIRE ALARM .0 Phone: (206)641 -4564 BELLEVUE WA 98008 Phone: 206 - 320 -9063 Phone: 425- 277 -5444 4 „LicI..t_ Date: a- /3-0/ I hereby certify that I have re =nd examined tHis p ermi and know the same to be true and correct. All pr • isions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development pe mit. ii Signature: Print Name: Date: -a . / 3 ' Q / This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Address: 411 STRANDEF BL Suite: Tenant: Type: DEVPERM Parcel #: 022320 -0052 CITY OF TIiKWILA Permit No: 001-020 Status: ISSUED Applied: 01 /25/2001 ts ued: 02/13/2001 *** k** k * ** k k * * * * * ** 4* 4# * ** k k 4 *** 1 * 4 A k k r k k k k k k k 4 k+ 4*** k k k* A k k k* k k k k k k k k k 4 k k k Permit Conditions: 1. No chanoes w i 1 1 be made to the plans unless approved by the Engineer and the Tukwila Building Division. 2 walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 3. Any exposed insulations backing material ;hall have a Flame Spread Rating of 25 or less, and material sha i 1 bear ident i fication showing the fire performance rating thereof. 4. All construction to be done in conformance with approved plans and requirements of t h e Uniform B u i l d i n g Code (199: Edition) as amended. Uniform Mechanical Code (1997 Edition). and Washington State Energy Code ( 1 9 9 7 E d i t i o n ) . 5. Plumbing permits shall be obtained through the Seattle-King County Department of P u b l i c Health. P l u m b i n g w i l l be inspected by that agency. i nc 1 ucd i ny ail yas p i p i nu (296- 4722). G. Validity of Permit. The issuance of a permit or approval of plans, specifications. and computations _.h<jl i not be con- strued to be a permit for, or an approvai of. any violation of any of the p r o v i s i o n s of the b u i l d i n g code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 7. Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (248-6630). 8. All permits, inspection records, and approved plans shall be available at the job site prior to the start of any con - struction. These documents are to be maintained and avail- able until final inspection approval is granted. 9. ** *FIRE DEPARTMENT CONDITIONS*** 10. The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 11. The total number of fire extinguishers required for your establishment is calculated at one e.'t.inquisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 106:C) dry chemical type. Travel distance to any fire extinguisher must be 7S' or less. (NFPA 10, 3 -1.1) 12. Portable fire extinguishers shall be securely installed on the hanger or in the bracket supplied, places in cabinets or wall recesses. The hanger or bracket shall be securely and properly anchored to the mounting surface in accordance with the manufacturer's instruction. The extinguisher shall be i n s t a l l e d so that the top of the extinguisher is not more than 5 feet above the floor and the clearance between the bottom of the extinguisher and the floor shall not be less than 4 13, Extinguishers s h a l l - located so as to be in o ► a-i n v i e w (if at all possible) , or if not in plain view. they shall be identified with a sign stating. "Fire Extinguisher", with an arrow pointing to the unit. (NFPA 10. 106,3) (UFA., Standard 10 -1) 1 4 . Clear access to f i r e extinguishers i s required at a l l times. They may not be hidden or obstructed. (NFPA 10. 1 -6.5) 15. Fire extinguishers require monthly and yearly instectiions. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall Identify the company or eersoo performing the service. (NFPA 10, 43, 4 -4 and 4-4.3) Every six years. dry chemical and halon type fire extinguishers shall be emptied and subjected to the applicable recharge procedures. (NFPA JO. 4 -4.1) If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection taq is not complete, a reputable fire extinguisher service company w i l l be required to conduct these required surveys. (NFPA 10, 4 -3. 4 -4) 16. Maintain fire extinguisher coverage throughout. 17. No point in an unsprink lered building may be more than 200 feet from an exit. measured along the path rat travel. (UBC 1004.2.5.2.1) 18. No point in a sprinklered building may be more than 250 feet from an exit.. measured along the path of travel. (UBC 1004.2.5.2.2) 1 9 . Exit doors s h a l l swing i n the direction o f e x i t Crave i when serving any hazardous area or when serving an occupant load of 50 or more. (UBC 1003.3.1.5 20. Exit doors shall be openable from the inside without the use of a key or any special knowledge or e f f o r t . E x i t doors shal 1 not be locked, chained, bolted, barred. latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) 21. Dead bolts are not allowed on a u x i l i a r y exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant. space. (UFC 1207.3) 2 2 . When two or more exits from a story are required, e x i t signs shall be installed at the required exits and where otherwise necessary to clearly indicate the direction of egress. (UBC 1003.2.8.2) 23 . When two or more exits from a story are required and when two or more exits from a room or an area are required. e x i t signs shall be illuminated. (UBC 1003.2.8.4) N. Internally illuminated exit signs shal 1 have both bulbs working at all times. (UI3C 1003.2.8.4) 25. Exits shall be illuminated any time the building is occupied with light having an intensity of r►ot less than 1 foot candle at floor level. Fixtures required for exit illumination shall be supplied from separate sources of power for Group I, Division 1.1 and 1.2 occupancies and for all other occupancies where the exiting syseem serves an occupant load of 100 or more. (UBC 1003.2.9. 1003.2. 9.2) 26. The power supply for means of egress illumination shall normally be provided by the premises' electrical supply. In the event of it's failure, illumination shall he automatically prov i `" from an emergency sys tem "tr Group I, Divisions 1.1. art.. 1.2 occupancies and for a, . other. occupancies where the means of egress system serves an occupant load of 100 or more. such emergency systems shall be installed in accordance with the electrical code . (UPC 1003.9.2) 27. All exit signs shall be illuminated at all tinge:. To ensure continued illumination for a duration of not less than 1 1/2 hours in case of pr•iniary power loss. the exit signs shall also be connected to an emergency electrical system provided from storage batteries. unit equipment: or an on s i t e generator s e t . and the system s h a l l be installed in accordance with the electrical code. (UBC 1003.2.8.5) 28. MaintSan sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls. closets or partitions may require relocating and /or adding sprinkler heads. 29. Sprinkler protection shall be extended to a 1 1 areas where required, including all enclosed areas, below obstr#rctions and under overhangs greater than four feet wide. (NFPA 13-4-5.5.3.1) 30. A l l new sprinkler systems and a l l modifications to e x i s t i n g sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual. Industrial Risk Insurers, Kemper or any other representative designated and /or recorgn i zed by the City of 1'ukw i l u . prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1901) 31. All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to the Tukwila F i r e Prevention Bureau must be stamped w i t h the appropriate level of competency seal. (WAC ?12 - -80) 32. Maintain automatic fire detector coverage per N.E. R.A. 72 Addition /relocation of walls. closets or partitions: may require relocating anti /or adding automatic fire detectors. 33. Maintain square foot coverage of detectors per manufacturer's specifications in all areas including closets, elevator shafts, top of stairwells, etc. tNFPA 72, 5-1.4.2) 34. All new fire alarm systems or, modifications to existing systems shall have the written approval of the T u k w i l a fire Prevention Bureau. No work shall commerce until a fire department permit has been obtained. (City Ord i nand= #1900) tUFC 1001.3) 35. A l l e l e c t r i c a l work and equipment shall conform s t r i c t l y to the standards of The National Electrical Code. (NFF'A 70) 36. An aisle to and working space shall be provided for each electrical panel. An aisle width not less than 24 inches shall provide access to the panel and 30 inches of working space shall be provided directly in front of the Runes. (NEC 110 -16(a) , NEC 110-16(c)) 37. Each circuit breaker shall be legibly marked to indicate it's purpose. (NEC 110-22i 38. Required fire resistive construction. includ inq oc.2upartcv separations, area separation walls, exterior wa 1 is due to location on property, fire resistive requirements based on type of construction, draft _stop p a r t i t i o n s and roof coverings shall be r as specified in t' -` Building Code and Fire Code a.,d shall be properly repairs._,, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 1111.1) 39. The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 8 -B of the Uniform Building Code. (UBC 804.1) 40, Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers shall contrast with their background. (UFC 901.4.4) 41. In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. (UFC 901.4.4) 42." Fire Department lock boxes shall be provided for access to all fire alarm panels and sprinkler risers. The appropriate key(s) for access shall be placed in the lockbox. Lockbox order forms must be obtained from the Tukwila Fire Department. (City Ordinance *1900). 43. Contact the Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance *1900 and #1901) 44. This review limited to speculative tenant space only .. special fire permits may be necessary depending on ;seta i led description of intended use. 45. Any overlooked hazardous condition and /or v i o l a t i o n of the adopted Fire or Building Codes does not imply approval of such condition or violation. 46. The plans were reviewed by _512_. If you have any questions, please call the Tukwila Fire Prevention Bureau at (206)575 -4407. I hereby certify that I have read these condition ; and w i l l comply with them as outlined. A) 1 provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give a u t h o r i t y to violate or cancel the provisions of any other work or local laws regulating construction or the performance of word;. Signature: Print Name: Date: Project Name/Tenant: a _ , ,. • ..3 \11'" OWY1WIDY) Value of Constru Site Address (include s it nummer) 1 4 j City St�te/Zip —. I 110 Tax Pa{ •1 . un _] Property Owner: 1 ` I i ! , .. . Phone: Street Address: Will there be a change of use? ❑ yes P no 5frci 'n 1 / (....)) 41 City State/Zip: Fax #: Contractor: lA (/ (C1/ A1. 72 5 44 Street Address: p V / 11111?._ n C StztelZip: Fax #: Architect: Phon Street Address: iiit. A / City " . • • F Fax #. / • b I_- �. Engineer: ' C]C7‘\ � / - � � v ‘ S Phone: y Street Address: City ty StatelZip: Fax It: Contact Person: �c Ilir Phonez 06 324 / — c3 Street Address: (2 c) -7 .- ' 4 f 2 . „ , VtrP: Fax #: 70L 7 x_5 4 Description of work G _A. 1 to be done (please be specific): A 'r A al i7 ' A . 0J- 4 lt A r IA m . Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ School /Colle :e /University ❑ Other / ❑ Warehouse i ❑ Hospital ❑ Offic Proposed use: ❑ Retail ❑ Restaurant ❑ Multi - family ❑ Warehouse ❑ Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel, ❑ Office ❑ School /Colle :e/Universit , ❑ Other ' Z C._ O _ Building Square Feet: (T D existing No. of Stories: - 3 Area of construction (sq ft): Will there be a change of use? ❑ yes P no If yes, extent of change: (Attach additional sheet if necessary) , RECEIVED . Will there be rack storage? ❑ yes L4d'no Existing fire protection features: ❑ sprinklers 2 automatic fire alarm CI none ❑ other !mill 70 I in the building? ❑ yes ❑ no X 11 paper indicatin quan tities & Material Say •lJ1t Will there be storage of flammable/combustible hazardous material Attach list of materials an stor location on separate 8 1/2 CITY OF TU "WILA Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 (206) 431 -3670 Project Number: Permit Number: Dc).- 020 Commercial / Multi- Family Tenant Improvement / Alteration Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT REQUEST FOR PUBLIC WORKS SITE/CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews ma he determined b the Public Works De . artment) ❑ Channelization/Striping in Curb cut/Access/Sidewalk ❑ Fire Loop/Hydrant (main to vault) #: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension ❑ Water Meter /Exempt It: Size(s): 0 Deduct ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: ❑ Miscellaneous ❑ Flood Control 0 Zone ❑ Hauling ❑ Landscape Irrigation O Private 0 Public O Private 0 Public Water Only gal Schedule: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of th Uniform Building Code (current edition). No application shall be extended more than once. PLEASE SIGN BACK OF APPLICATION FORM Date application 11 / 3 0 /00 crpernir.dor. ted: Date application expires: — — O Appl tikep by: (initials) , (� BUILDING OWNER .: UTHORIZE AGENT: Signature: Date: ' — ZS )) � ' . � • '� Fax #:2 ' r [� Print name: AIL P ., *— .fi r ` Address -` _C� 7 • Z City /St 4 �. APPLICATI t , MUST BE SUBMITTED WITH THLLOWING: ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A WWI ❑ Cr omplete Legal Description lr ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : 11/30/00 clpermil.dac Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing/grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H -9). 51 /Floor plan: show location of tenant space with proposed use of each room labeled Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ Vicinity Map showing location of site Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack I yout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ dicate proposed construction of tenant space or addition and walls being demolished ❑ Construction details ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. Food service establishments require two (2) sets of stamped approved plans by the Seattle - King County Department of Public Health prior to submitting for building permit application. The Department of Public t Health is located at 999 Third Avenue, Suite 700, Seattle, WA or call (206) 296 - 4787. (Form H - 5) ❑ ❑ opy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PER JURY BY HE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. I <282_ This Payment v4E1.25 • 1=1 LLL t******-4********4**44,04. *** 4,4 *kh*i** 4- k4*4+4 1 (40firk ,, 444,r4-14i+ / Akti t CI1Y OF TUkW1LA. WA 71, 4**4.V************44,444,444 t** 4 4 * 4 Aytifkk'4 4v 444 k4 t 2 M Da TPRNSMII Number: RQ100164 Nnount: l.NC..! ()..''tW/1. Patiment Method: CHECK Nol CHOOW,3 F..;;Fl:,P Eq.';: KI), h • . _ .....__. law _ P4relit No: 001-020 fvoo; GE0N:RM DE Pait■ P ' Parcel No: 022:l20-00!;2 4:5 Site Addhe45: 411 3rRANoER I1L .Z 1110 01r. 0 rot:Al Feei: k.j)f-,tYi Iota, ALL Pmt!,: BALinQe: Account Code Derir.riution Amou,,t 000/n2.100 hUILC!ING - CONELS 000/386.904 STAIE BUILDING ( .iURCHAE. 4.'30 Do 1- '11 TOTAL pleagelErnMENMEMMISAX tO :t* ********* kA:itkAA***A4 * AIN OF TOLIMA. W 11 .)t h************* 4 * . *********JA/***CM)** , *iA*44*AAA*44444*tiAN* TTAN5M1T Nuchf-r: H0100104 Amcunt: 41EL4e, 01,:":./01 Payment Method: CHECK Notation: rOmpS ,!ri) Perm)t Na: G01-020 OEVPERM OV,ELOPmENI PEllnif Parcel No: 022.120-00!■: site Addre55: 411 t3TRANDEll 131. rotAt Foei: This Puvment 41O.44 loti ALL lnt 4 1E;.44 d a 1 inc: *** * * * * * * * * ********************************* 47%***•*****t****0 ■ Account Coda Desc!siotlon Amr. 000/345.030 PLAN CHECV - 0001J-. 9710 TI.ITAL. 4 t4 ISNSNSMgStaEenaatMEMftr : ' ' Project: T- 5" v,' i i 4' e4 , Type,nfirtspttettion: -- 1u I c' '- -, t� _ ___ ''' .t/.!- 1, G Address: il/,/ Sr, - �4 .An/0c AP 502. al / 1 / / Special instructions: Date walled: a.m. Rueter: ), 1 "'1 k - (�a Phone: INSPECTION NO. COMMENTS: Receipt No: INSPECTION RECO1.J Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 Approved per applicable codes. 0 Corrections required prior to approval. Inspector: Date: tokod PERMIT NO. (206)431 -367 Date: 2, - ` c ri $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reins ection. S. Cot: J: �1��fYt9e'l Y `4P. Project• ' L�� I C OpIie Type of Inspection: (1,11 i•t v /1 .J Address: 411 l Atoil ry 13i Date called: ' - zg.,-oi . Special instructions: • j ., 7 )ir�'t c.L � - J rn ti) c r.1 _ D ate wanted: U L(t -DI �") p. Requester: fi 1 Phone: ' /b( ' 5 —( )e) INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: INSPECTION REC(R1) Retain a copy with permit Inspector: /j9 PERMIT NO. (206)431 -3 Date: Corrections required prior to approval. 0 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: : Date: Project : —j ,,. • Jr� d )/1 ) Y'i Type of Inspection: (1 /2. p.f�,c !.1. Address: ,- u i , )T) /if ,- .. , ,d. Date called: ‘;?/ /c / foot Special instructions: t ,( `ii�.rY Date ant : f i5 / a.m.. p.m. Requester: - f 7 r) ) Phone: r 1. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 proved per applicable codes. Corrections required prior to approval. COMMENTS: INSPECTION RECO Retain a copy with permit PERMIT NO. (206)431- Inspector: �� j ct. 0 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: M2 , r 5 Receipt No: Date: 1 Projec Type of Inspect' Addres : Date called: Speci I instructions: Date wanted: 2. 3-0 / a.m. P.m. Requester: Phone: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 tk pproved per applicable codes. COMMENTS: Inspector: r) INSPECTION RECOR Retain a copy with permit Corrections required prior to approval. Date: D5I-o2-0 Eli $47.11TR INSPECTION E REQI4 RED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 1t110. Call to schedule reinspection. Receipt No: Date: • PERMIT NO. (206)431-367 • 4t414I 3-6 1.; J Address City of Tukwila Fire Department TURWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name I i? '/ %. / Ain )c1kf Retain current inspection schedule X Needs shift inspection Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: t ` Pre -Fire: Permits: Authorized Signature FINALAPP.FRM F T.F.D. Form F.P. 85 John W. Rants, Mayor Thomas P. Keefe, Are Chief �` C5 Permit No. -� 2 , / ' Date Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone (206) 575-4404 • Fax (206) 575-4439 Location Description Allowed Watts per ft= or per If Area in ft' (or If for perimeter) Allowed Watts x fe (or x It) Covered Parking 0.2 W/ft Open Parking A A 0.2 WRt V\; 0.2 W/ft Bldg. (by facade) 0.25 W/ft Bldg. (by perfm) 7.5 Will CAT of r � w,. �� , ,, Note: for building exterior, choose either the facade area or the perimeter method, but not both) }}al Allowed Watts C AI ') , .,„ . Location Fixture a - . ription Number of Fixtures Watts/ Fixture Watts Proposed A A Total Proposed Watts may not exceed Total Allowed Watts for Exterior Total Proposed Watts Lighting Summ. LTG-SUM 1997 Washington State Nonresidential Energy Code Compliance Forms 1997 Washin ton State Nonresidential Ener• Code Compliance Form Project Info Project Description Project Address 4i ( � (2 v ) n ✓ Applicant Name: Applicant Address: �i _ Applicant Phone: �" ❑ New Building ❑ Addition Alteration Date ..{)/ For Building tfepartme Use 'O ? S ° c\6 11 X Maximum Allowed Lightin lion `� \.. (floor no.) Q. h Qd Y ( 1 Qj " From Table Gti ) xerasilleasm D om! Pro used Li _ htin 5.1 (over) • document al exceptions tak = from footnotes Total lowed Watts `"'r1' Watta : e (Interior) (May not exceed Total Allowed Watts tor Interior) rAn Compliance Option Alteration Exceptions (check appropriate box) ❑ No changes are being made to the lighting Catc8is than 60% of the fixtures are new, and installed lighting wattage is not being increased Location (floor /room no.) Prescriptive ❑ Lighting Power Allowance ❑ Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces dearly on plans.) Use mfgr listed maximum input wattage. For fixtures with hard -wired ballasts only, the Wattage (Inter' default table In the NREC Technical Reference Manual may also be used. Occupancy Description Fixture Description Mowed Watts • r ft Number of Fixtures Area in ft Mowed x Area Watts/ Fixture First Edition -June 7998 Watts Proposed 3E1= 50 =Li L Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watt! 4 1 , Use mfgr listed maximum Input wattage. For fixtures with hard -wired ballasts only, the Wattage (Exterior) default table in the NREC Technical Reference Manual may also be used. Proposed Lighting Proposed Lighting Wattage (Exterior) (May not exceed Total Mowed Watts for ExteWOF) . iT CENT Mechanical Permi lans Checklist 1997 Washington State Nonresidential Energy Code Compliance Forms MECH -CHK First Edmon -June 1998 Mechanical - General Requirements 1411.1 Genets!: Equipment shah have a minimum performance at the specified rating conditions not less than the values shown in Table 14-1 through 14 -3. 1411.2 Rating Conditions: Cooling equipment shall be rated al ARI test conditions and procedures when available. Where no applicable procedures exist. data shall be furnished by the equipment manufacturer. 1411.3 Combination Specs and Servi:a Water Hosting: For combination space and service water heaters wth a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have ether an Energy FActor (EF) or a CAE at not less than the following: 1411.4 Packaged Electric Heating and Cooling Equipment: Packaged electric equipment providing both heating and cooing with a total cooling capacity greater than 20,000 Btulh shall be a heat pump. Exception: Unstilted equipment Outliers or cabinets used solely for personal wireless service faciliies. 1 412 Controls 1412.1 Temperature Controls: Each system shal be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature withh the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Broadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees Fwthn which the supply dheating and cooing energy to the zone is shut off or reduced to a mhimum. Exceptions: 1. Specie' occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buldings complying with Section 1 141.4, if in the proposed building energy analysis, heating and cooing thermostat setpoints We set to the same temperature between 70 degrees F and 75 degrees F Inclusive and assumed to be constant throughout the year. 3. Thonnostats that require menus/ changeover between heeling and cooing modes. 1412.3 Humidity Controls: If a system is equipped wth a means for adding moisture, a humidistat shall be prov ided. 1412.4 Setback end Shut-011: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction d energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a mhimum seven -day clock and be capable of being set for seven d if erent day types per week. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment wth full bad demands of 2 kW (8,826 Btu/h) or less may be controlled by readly ax essbio manual off -hour controls. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall bo equipped with dampers which close automaticaly when the system is off or upon power Wise. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 1412.6 Heat Pump Controls: Untary air cooled heat pumps shal include microprocessor controls that minimize suppbmentai heat usage during start -up, set -up, and defrost condtions. These controls shall anticpate need for heat and use compression heating as the first stage d heat. Controls shall indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Multi shat have modulating or staged combustion control. Exceptions: 1. Boilers. 2. Radiant Heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shal have a means to balancing, including but not limited to, dampers. temperature and pressure test connections and balancing vaives. 1413 Air Economizers 1413.1 Operation: Air economizers that be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooing. 1997 Wr -him ton State Nonresidential Ener. Code Comrt=ance Form 14132 Control: Mr economizers shall be controlled by a control system capable d determining if outside air can meet part or al of the buiding's cooing loads. 1413.3 Integrated Operation: Building Heating Energy: Air economizers that be capable of providing partial cooling even when additional mechanical cooing is required to meet the remainder d the cooing load. Controls shall not preclude the economizer operation when mechanical cooling is required shutaneousy. Exception: Economizers on individual, died expansion, cooing systems with capacities not greater than 75,000 Btu/h may Include contras dial limit i mu taneous operation of the economizer and mechanical c ,oing for the purpose of preventing ice formation on cooing coils. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 hch water column static pressure shall be sealed in accordance with Standard RS-18. Extent d sealing required is as folows: 1 Static pressure: 1/2 rich to 2 inches; seal transverse joints. 2. Stoic pressure: 2 inches to 3 Inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 richer, seal a transverse joints. longitudinal seams and duct wail penetrations. Duct tape and other pressure sensitive tape shat not be used as tho primary sealant where ducts are designed to operate at static pressures of 1 Inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the buidhg envelope, by 'scanting interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include hsulatbn nataiation, moisture control, at leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air buvers must be isolated from the conditioned space by insulating surfaces to a mhimum o f R -11 and any exterior envelope surfaces per Chapter 13.Oasts air duct runs are considered buiding envelope untl they, a. connect to the heating or cooling equipment, or b. are isolated from the exterior w*h an automatic shut-off damper Once outside air ducts meet the above fisted requirements, any runs wthin condtioned space must comply with Table 14-5 requirements. °her duds and plenums shal bethermaly insulated per Table 14-5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a space that serves that space ony. 1416 Piping Systems 1416.1 Insulation: Piping shal be therm aly insulated in accordance wth Table 14-8. Exception: Piping instated within unitary HVAC equipment. Water Pees outside the conditioned space shall be Insulated in accordance with Washington State Plumbing Code (WAC 51.26) 1420 SIMPLE SYSTEMS (PACKAGED UNITARY EQUIPMENT) 1421 System Type: To drafty as a simple system, systems shall be one of thefolbwing: 1. Air cooled. constant volume packaged equipment, which provide heating, cooling or both, and require only external connection to duct work and energy services. 2. Ai cooled, constant volume spit systems, which provide heating, cooling or both. with cooling capacty of 84,000 Btu/h or less. 3. Heatng only systems which have a capacity of less than 5,000 cfm or which have a minimum outside air supply d less than 70 percent of the total air circulation. All other systems shall comply with Sections 1430 through 1438. 1422 Controls: In ad cilia n to the control requirements in Section 1412. where separate heating and cooing equipment serve the same temperature zone thermostats shat be interlocked to prevent simutaneous heating and cooing. Systems which provide heating and cooling sinutaneousy to a zone are prohibited. 1423 Economizers: Economizers meeting the requirements of Section 1413 shal be hstaled on single package untary fan-cooing units having a supply capacity d greater than 1,900 dm or a total cooling capacty greater than 54,000 Btu/h. The total capacity of al units without economizers shal not exceed 24 0.00 0 ER VII per building. or 10% of is aggregate cooling (economizer) capacity, whichever is greater. 1424 Separate Air Distribution Systems: Zones with special process temperature requirements and/or humidity requirements shall be served by separate air distribution systems from those serving zones requiring only comfort cond EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gat storage 0.55 0.70 Mechanical Permi lans Checklist 1997 Washington State Nonresidential Energy Code Compliance Forms MECH -CHK First Edmon -June 1998 Mechanical - General Requirements 1411.1 Genets!: Equipment shah have a minimum performance at the specified rating conditions not less than the values shown in Table 14-1 through 14 -3. 1411.2 Rating Conditions: Cooling equipment shall be rated al ARI test conditions and procedures when available. Where no applicable procedures exist. data shall be furnished by the equipment manufacturer. 1411.3 Combination Specs and Servi:a Water Hosting: For combination space and service water heaters wth a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have ether an Energy FActor (EF) or a CAE at not less than the following: 1411.4 Packaged Electric Heating and Cooling Equipment: Packaged electric equipment providing both heating and cooing with a total cooling capacity greater than 20,000 Btulh shall be a heat pump. Exception: Unstilted equipment Outliers or cabinets used solely for personal wireless service faciliies. 1 412 Controls 1412.1 Temperature Controls: Each system shal be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature withh the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Broadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees Fwthn which the supply dheating and cooing energy to the zone is shut off or reduced to a mhimum. Exceptions: 1. Specie' occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buldings complying with Section 1 141.4, if in the proposed building energy analysis, heating and cooing thermostat setpoints We set to the same temperature between 70 degrees F and 75 degrees F Inclusive and assumed to be constant throughout the year. 3. Thonnostats that require menus/ changeover between heeling and cooing modes. 1412.3 Humidity Controls: If a system is equipped wth a means for adding moisture, a humidistat shall be prov ided. 1412.4 Setback end Shut-011: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction d energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a mhimum seven -day clock and be capable of being set for seven d if erent day types per week. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment wth full bad demands of 2 kW (8,826 Btu/h) or less may be controlled by readly ax essbio manual off -hour controls. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall bo equipped with dampers which close automaticaly when the system is off or upon power Wise. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 1412.6 Heat Pump Controls: Untary air cooled heat pumps shal include microprocessor controls that minimize suppbmentai heat usage during start -up, set -up, and defrost condtions. These controls shall anticpate need for heat and use compression heating as the first stage d heat. Controls shall indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Multi shat have modulating or staged combustion control. Exceptions: 1. Boilers. 2. Radiant Heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shal have a means to balancing, including but not limited to, dampers. temperature and pressure test connections and balancing vaives. 1413 Air Economizers 1413.1 Operation: Air economizers that be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooing. 1997 Wr -him ton State Nonresidential Ener. Code Comrt=ance Form 14132 Control: Mr economizers shall be controlled by a control system capable d determining if outside air can meet part or al of the buiding's cooing loads. 1413.3 Integrated Operation: Building Heating Energy: Air economizers that be capable of providing partial cooling even when additional mechanical cooing is required to meet the remainder d the cooing load. Controls shall not preclude the economizer operation when mechanical cooling is required shutaneousy. Exception: Economizers on individual, died expansion, cooing systems with capacities not greater than 75,000 Btu/h may Include contras dial limit i mu taneous operation of the economizer and mechanical c ,oing for the purpose of preventing ice formation on cooing coils. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 hch water column static pressure shall be sealed in accordance with Standard RS-18. Extent d sealing required is as folows: 1 Static pressure: 1/2 rich to 2 inches; seal transverse joints. 2. Stoic pressure: 2 inches to 3 Inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 richer, seal a transverse joints. longitudinal seams and duct wail penetrations. Duct tape and other pressure sensitive tape shat not be used as tho primary sealant where ducts are designed to operate at static pressures of 1 Inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the buidhg envelope, by 'scanting interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include hsulatbn nataiation, moisture control, at leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air buvers must be isolated from the conditioned space by insulating surfaces to a mhimum o f R -11 and any exterior envelope surfaces per Chapter 13.Oasts air duct runs are considered buiding envelope untl they, a. connect to the heating or cooling equipment, or b. are isolated from the exterior w*h an automatic shut-off damper Once outside air ducts meet the above fisted requirements, any runs wthin condtioned space must comply with Table 14-5 requirements. °her duds and plenums shal bethermaly insulated per Table 14-5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a space that serves that space ony. 1416 Piping Systems 1416.1 Insulation: Piping shal be therm aly insulated in accordance wth Table 14-8. Exception: Piping instated within unitary HVAC equipment. Water Pees outside the conditioned space shall be Insulated in accordance with Washington State Plumbing Code (WAC 51.26) 1420 SIMPLE SYSTEMS (PACKAGED UNITARY EQUIPMENT) 1421 System Type: To drafty as a simple system, systems shall be one of thefolbwing: 1. Air cooled. constant volume packaged equipment, which provide heating, cooling or both, and require only external connection to duct work and energy services. 2. Ai cooled, constant volume spit systems, which provide heating, cooling or both. with cooling capacty of 84,000 Btu/h or less. 3. Heatng only systems which have a capacity of less than 5,000 cfm or which have a minimum outside air supply d less than 70 percent of the total air circulation. All other systems shall comply with Sections 1430 through 1438. 1422 Controls: In ad cilia n to the control requirements in Section 1412. where separate heating and cooing equipment serve the same temperature zone thermostats shat be interlocked to prevent simutaneous heating and cooing. Systems which provide heating and cooling sinutaneousy to a zone are prohibited. 1423 Economizers: Economizers meeting the requirements of Section 1413 shal be hstaled on single package untary fan-cooing units having a supply capacity d greater than 1,900 dm or a total cooling capacty greater than 54,000 Btu/h. The total capacity of al units without economizers shal not exceed 24 0.00 0 ER VII per building. or 10% of is aggregate cooling (economizer) capacity, whichever is greater. 1424 Separate Air Distribution Systems: Zones with special process temperature requirements and/or humidity requirements shall be served by separate air distribution systems from those serving zones requiring only comfort cond Project Address f75r 6 1, 1L, rate ) _ 2 ) in the The following information Is necessary to check a lighting permit application for compliance with the lighting requirements 1994 Washington State Nonresidential Energy Code. Applicability (circle) Code Section Component Information Required Location on Plans Buildng Department Notes LIGHTING CONTROLS (Section 1513) ram no n.a. 1513.1 Local controVaccess Schedule with type, Indicate locations re. no n.a. 1513.2 Area controls Maximum limit per switch 1513.3 Daylight zone control Schedule with type and features, indicate locations re. no n.a. vertical glazing indicate vertical glazing on plans re. no n.a. overhead glazing Indicate overhead glazing on plans ros so n.a. 1513.4 Display/exhib/special Indicate separate controls 1513.5 Exterior shut-off Schedule with type and features, indicate location yes no n.a. (a) timer w/backup_ ItIptiotocell. Inter. auto shut-off Indicate location Indicate location Indicate location Vas no n.a. 1513.6 F" no n.a. 1513.6.1 (a) occup. sensors (b) auto. switches Schedule with type and locations Schedule with 1-e and features (back-up, override capaba ); rim so a. a. 1513.6.2 Indicate size of zone on plans UGHTING WATIAGE (Sections 1520-22 or 1530-32) t'ii so Ughting Sum. Form Completed and attached. Schedule with fixture I- es, lamps, ballasts, watts per fixture ELECTRIC MOTORS jtion 151j) 1997.Washington State Nonresidential Energy Code Comnliance Form Lighting Permit P s Checklist 1997 Washington State Noises nee! Energy Code Coqp&e Forms LTG-CHK Flistelnkm-Joe199a no n.a. I E.c motor effidoncy MECH-MOT or Equipment Schedule with hp, rpm. efficiency if "no" Is circled for any question, provide explanation: Use' LPA = (Wlft) Use' LPA' (Wlft') Painting, welding, carpentry, machine shops 2.3 Police and fire stations" 1.2 Barber sho &beauty shops 2 Atria (atriums) 1 Hotel banquet /conference/exhibitionhai'•' 2 Assembly spaces , auditoriums, gymnasia 1 Laboratories 2 Process plants 1 Aircraft repair hangars 1.5 Restaurantslbars 1 Cafeterias fast food establishments 1.5 RetaidA 1 Factories, workshops, handling_ areas 1.5 R eta it 8 10 , R eta it banking 1.5 Gas stations auto re. air sho .s 1.5 Locker and/or shower facilities 0.8 Institutions 1.5 W arehouses" store .a areas 0.5 Libraries 1.5 Aircraft storage hangars 0.4 Nursin. homes 1.5 Parkin. . are. es EMI Siren 1 $33 W holesate stores (pallet rack shelving) 1.5 Mall concourses 1.4 Plans Submitted for Common Areas Only' Schools buildings, school classrooms, day care centers 1.35 Common area corridors, lobbies (except m all concourse) 0.8 Laundries 1.3 Toilet facilities and washrooms 0.8 Office buildings, officeladministrative areas in facilities of other use types (Including but not imited to schools, hospitals, Institutions, museums, banks, churches)'" 1.2 - Prescriptive Spaces Occupancy ❑ Warehouses, storage areas or aircraft storage hangers ❑ Other Qualification Checklist Lighting Fixtures: ((}deck here if at least 95% of fixtures In the space meet all four criteria: Note: if occupancy type is 'Other and fixture answer is checked, the number of fixtures in 1. Fixtures are fluorescent, non - lensed, with only one or two lamps, and the space is not limited by Code. Clot indicate these spaces on plans. If not 2, Lamps are , and 3. Lamps T-S, T-8 or PL, s are 5-50 Watts, and P qua deed, do LPA Calculations. 4. Ballasts are electronic ballasts 1997 Washington State Nonresidential Energy Code Compliance Forms 1997 W ' • 'ngton State Nonresidential Energy Code Com Form Lighting Summar back) LTG -SUM First Edition • June 1998 Table 15 -1 Unit Lighting Power Allowance (LPA) for Interior Lighting Footnotes for Table 15-1 1. In cases in which a use is not mentioned specifically, the Unit PnwerAllnnance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt amts. 2. The watts per square foot may be increased by two percent per toot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3. Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4. For all other spaces, such as seating and common areas, use the Unit light PnwerAllonance fa assembly. S. Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6. Includes pump area under canopy. 7. In cases in which a lighting plan is submitted for only a portion of a floor, a Unit Lighting Power Allowance of 1.35 may be used for usable office floor area and 0.80 watts per square foot shall be used fa the common areas, which may include elevator space, lobby area and rest rooms. Common areas, as herein defined do not include mall concourses. 8. For the fire engine room, the Unit Lighting Power Allowance is 1.0 watts per square foot. 9. For indoor sport tournament courts with adjacent spectator seating, the Unit Lighting Power Allowance fa the court area is 2.6 watts per square foot. 10. For both Retail A and Retail B, light for free - standing display, building showcase illumination and display window illumination installed within two feet of the window are exempt. Retail A allows a Unit Lighting Power Allowance of 1.0 watts per square foot. Ceiling mounted adjustable tungsten halogen and HID merchandise display illuminaries are exempt Retail B allows a Unit Lighting Power Allowance of 1.5 watts per square foot, including all ceiling mounted merchandise display luminaries. 11. Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, fa computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. 1997 W -chin • ton State Nonresidential Enerq Code Comoiiance Form Lighting Permit . ns Checklist 1997 Washington State Nonresidential Energy Code Compliance Forms LTG -C H K Fitt! Edition -June 1998 Lighting - General Requirements 1513 Lighting Controls 1513.1 Local Control and Accessibility: Each space, enclosed by wale or ceiling-height pa4itims, shah be provided with sighing controls located within that space. The lighting controls, whether one or more, shall be capable of turning tit all lights within the space. The controls shall be readily accessble, at the poirt of entry/exit, to personnel occupying or usingthe space. Exceptions: The fdlowing fighting controls may be centralized in remote locations: 1. Lighting controls br spaces which must be used as awhde. 2. Automatic controls. 3. Controls requiting trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be cont pled from a single switch or automatic control shall not exceed that which is provided by a twenty ampere circUt loaded to not more than eighty percent. A master control may be installed provided the inditidual swtches retain their capablityto function independently. Circuit treakers may not be used as the sole m owns d switcNng. Exceptions: 1. industrial or manufbcturing process areas, as maybe required forproduction. 2. Areas less than lye percent of the building footprint for footprints over 100,000 ft`. 1513.3 Daylight Zone Control: M daylghted zones, as defined In Chapter 12, both trader overhead glaring and adjacent b vertical glazing, shall be provided with individual contrds, or daylight- oroccupant-sensing automatic controls, whidi control the tights independent of general area I ghting. 1513.4 Display, Exhibition, and Specialty Lighting Controls:All driplay, e>'hibition, or specialty lighting shall be controlled independently of general area ghting. 1513.5 Automatic Shut -off Cortrols, Exterior. E,derior fighting not intended for 24-hour continuous use shall be automatically switched by timer, photocell, ora combination of timer and photocel. Automatic time switches shill also have program back-up capabilities, which prevent the loss of program and time settngs for a least 10 hours, if poweris interrupted. 1513.6 Automatic Shut -Off Controls, Interior: Office buid'ngs greater than 25,000ft and all school dassrooms Mal be equipped with separate automatic controls to shut off he lighting during unoccupied hours. Auomatic controls may be an occt,pancy sensor, tine switch, a other device capable of attomaticaiy shutting df Ighting. Exceptions: 1. Areas that must be contiruotaly illuminated, or illuminated in a manner regtiring manual operation of the fighting. 2. Emergency lighting systems. 3. Switching for industrial or manufacturing process faciitles as maybe required forproduction. 151a6.1 Occupancy Sensors: Occupancy sensors shad be capable of automatically tuning off al the lights in an area no more than 30 minutes after the area has been vacated. 1513.6.2 Automatic Time Switches: Automatic lime switches shall have a mirimum 7 day clock and be capable of being set for7 different day types per week and incorporate an auo mate holiday'shut•off' feature, which turns off all loads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power Isinterrupted. Automatic time switches shall incorporate an over -ride switching device which: a. Is readly accessble; b. is located so that a person using the device can see the lights or the areas cortroled by the switch, or so that toe area being illuminated is annunciated; c. Is manually operated; d. alowsthe lighting to remain on for no more than two hours when an override is initiated; and e. controls an wee not exceeding 5,000 ft z 5 percent of footprint for f ootprints over 100,000ft , whichever is greater. Lighting Power A - ance Adjustments LTG -LPA 1997 Washington State Nonresidential Energy Code Compliance Forms Project Address I Date Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for interior lighting. The Occupancy Description should agree with the 'Use' listed on Code Table 15-1. Identify the appropriate Ceiling Height Limit (9 feet, 12 bet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per square foot. Carry the Adjusted LPA to the corresponding 'Allowed Watts per ft location on LTG -SUM. Adjusted Li Location (floor /room no.) 1997 Wachin ton State Nonresidential Ener. Code Comoliance Form hting Power Allowances (Interior Occupancy Description First Edition -June 1998 Allowed Ceiling Height Ceiling Height limit Adjusted LPA Watts per ft " for this room for this exception" Watts per ft2 YAW " From Table 15-1 based on exceptions listed in footnotes ACTIVITY NUMBER: D01 -020 DATE: 1 -25 -01 PROJECT NAME: DR JIM SIMMONS SITE ADDRESS: 411 STRANDER BL XX Original Plan Submittal DEPARTMENTS: B ildiTlivision 00.0% 4 Pub is Wor s Response to Correction Letter # DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Er Incomplete Comments: TUES /THURS ROUTING: Please Route 20 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) Approved ri Approved with Conditions REVIEWER'S INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE Approved ri Approved with Conditions Not Approved (attach comments) REVIEWER'S INITIALS: DATE: V'IIR(I1111 INK N/1 PERMIT COORJCOPY PLAN REVIEW /ROUTING SLIP 1'L Fire Prevention nw& Structural C n n n SUITE NO: 202 Response to Incomplete Letter #__ Revision # After Permit Is Issued Pl �in Division L • t,••01 Permit Coordinator DUE DATE: 1 -30-2001 Not Applicable C No further Review Required DUE DATE 2-27 -2001 Not Approved (attach comments) r7 DEPARTMENTS: Building Division Public Works Complete Comments: Y'RRC/UIL IKK' vn PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D01 -020 DATE: 1 -25 -01 PROJECT NAME: DR JIM SIMMONS SITE ADDRESS: 411 STRANDER BL SUITE NO: 202 XX Original Plan Submittal Response to Correction Letter # C C Fire Prevention Fi Planning Division Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) APPROVALS OR CORRECTIONS: (ten days) Approved F7 Approved ,g Conditions[ 51\ REVIEWER'S INITIALS: CORRECTION DETERMINATION: Approved Approved with Conditions[1 REVIEWER'S INITIALS: Revision it After Permit Is Issued Response to Incomplete Letter -II Permit Coordinator n LI DUE DATE: 1 -30 -2001 Incomplete E Not Applicable LI TUES/THURS ROUTING: Please Route C Structural iew Required ri No further Review Required V REVIEWER'S INITIALS: DATE: I 'ea" 01 DUE DATE 2 -27 -2001 Not Approved (attach n ttach comments) ` DATE: 1" 0 I DUE DATE Not Approved (attach comments) DATE: PERMIT NO.: pou-ozo TENANT NAME: BUILDING PERMITS INSPECTIONS ❑ 00001 Progress Inspection Status ❑ 00002 Pre - construction ❑ 00003 Investigation ❑ 00004 OK to Occupy ❑ 00005 Remove Stop Work Order ❑ 00006 Follow -up ❑ 00007 Pre -Move Inspection ❑ 00050 WSEC Residential ❑ 00060 WA Ventilation/Indoor AQC ❑ 00070 NLEA Inspection/Modular Struct ❑ 00071 Mobile Home Tie Down insp ❑ 00072 Marriage Lines ❑ 00090 Rested ❑ 00095 Footing Drains ❑ 00100 Foundation Footings ❑ 00200 Foundation Walls ❑ 00250 Foundation Insulation ❑ 00300 Concrete Slab /Slab Insulation ❑ 00350 Crawl Space ❑ 00400 Shear Wall Nailing ❑ 00450 Plywood Wall Sheathing ❑ 00500 Roof Sheathing Nailing ❑ 00525 Plywood Deck Nailing ❑ 00550 Exterior Wall Sheathing ❑ 00600 Masonry Chimney ❑ 00610 Chimney Installation/All Types lie 00700 Framing ❑ 00750 Roof /Ceiling Insulation ❑ 00800 Floor Insulation ❑ 00801 Wall Insulation ❑ 00802 Exterior Roof Insulation ❑ 00803 Glazing Inspection ❑ 00815 Lighting and Controls El' 00900 Suspended Ceiling 2 01000 Interior Wallboard Fastening ❑ 01001 Exterior Wallboard Fastening ❑ 01110 Pre -Move Inspection ❑ 01115 Motor Inspection ❑ 01120 Pre -Demo ❑ 01140 Pre - reroof ❑ 01400 Final -Fire ❑ 01700 Final - Building 01900 Final - Reroof ❑ 03100 Site Visit ❑ 04000 Special - Concrete ❑ 04001 Special -Bolts in Concrete ❑ 04001 Special - Mom/Resist Conc Frame ❑ 04003 Special -Reinf Steel Prestress ❑ 04004 Special - Welding ❑ 04005 Special -High- Strength Bolting ❑ 04006 Special - Structural Masonry ❑ 04007 Special -Reinf Gypsum Concrete ❑ 04008 Special - Insulating Conc Fill ❑ 04009 Special -Spray Fireproofing ❑ 04010 Special- Piling, Piers, Caissons ❑ 04011 Special - Shotcrete ❑ 04012 Special- Grading, Excav/Fill ❑ 04013 Special- Retaining Wall ❑ 04014 Special - Panels ❑ 04015 Special -Smoke Control System CONDITIONS 0001 No changes to plans unless approved by Bldg Div ❑ 0010 Special inspection required, notify Bldg Div ❑ 0011 Special inspector shall submit final signed report ❑ 0012 New ceiling grid & light fixture shall meet lateral bracing t , 0013 Partition walls attached to ceiling grid ❑ 0014 Readily accessible access to roof mounted equipment ❑ 0015 Engineered truss drawings & calcs shall be on site Er 0016 Exposed insulation backing material ❑ 0017 Subgrade preparation including drainage. excavation ❑ 0018 Statement from roofing contractor verifying fire retardant class of roof , 0019 All construction to be done in conformance w /approved plans ❑ "No work shall be done in addition to those modifications..." (] 0002 Plumbing permits shall be obtained through King Co ❑ 0020 Structural observation shall be provided for this project ❑ 0021 All food preparation establishments must have King Co ❑ 0022 Fire retardant treated wood shall have flame spread of ❑ 0023 Notify Building Division prior to placing any concrete ❑ 0024 All spray applied fireproofing shall be special inspected ❑ 0025 All wood to remain in placed concrete shall be treated ❑ 0026 All structural masonry shall be special inspected Q 0027 Validity of Permit ❑ 0028 Rack storage requires separate permit 2'0003 Electrical permits obtained through L & 1 ❑ 0030 No occupancy of building until final insp by Bldg Div ❑ 0032 Remove all weeds, concrete, stone foundations. flat concrete ❑ 0036 Manufacturers installation instructions required on site ❑ "BTU maximum allowed per 1997 WA State Energy Code" ❑ 0035 Contact PW Div to obtain insp for water /sewer connect ❑ 0038 A C ofO will be required for this permit ❑ 0039 Final approval for all TI w /in the limits of the SC Mall ❑ 0004 All mechanical work shall be under separate permit ❑ 0040 All construction noise to be in compliance with 8.2 TMC ❑ 0041 Ventilation is required for all new rooms & spaces ge 0005 All permits, insp records & approved plans available ❑ 0006 All structural concrete shall be special inspected ❑ "Applicant shall obtain a separate plumbing permit from King Co" ❑ "Anchoring — All new construct and substantial improvement shall be anchored to prevent flotation" ❑ 0007 All structural welding shall be done by WABO certified inspector ❑ 0008 All high- strength bolting shall be special inspected ❑ 0009 Bolts installed in concrete shall be special inspected ❑ 0031 Comply with requirements of TMC 16.04 ❑ 0034 Removal of septic tanks require approval and compliance with King Co Health Dept. ❑ "Obtain required inspections from appropriate water & sewer districts" ❑ "Fuel burning appliances ❑ "Appliances, which generate...." ❑ "Water heater shall be anchored...." ❑ " Reroof' Plan Reviewer: Permit Tech: Date: 2 I'S Zoo( Date: �� ACTIVITY NUMBER: D01 -020 DATE: 1 -25 -01 PROJECT NAME: DR JIM SIMMONS SITE ADDRESS: 411 STRANDER BL Response to Correction Letter If DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ri Comments: REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved ri Approved with C nditions REVIEWER'S INITIALS: l� i /2- CORRECTION DETERMINATION: Approved n vhuroun LXM XX Original Plan Submittal PLAN REVIEW /ROUTING SLIP n Fire Prevention Structural Incomplete Revision # n SUITE NO: 202 Response to Incomplete Letter I After Permit Is Issued Planning Division Permit Coordinator TUES /THURS ROUTING: Please Route ri Structural Review Required n No further Review Required Approved with Conditions n Not Approved (attach comments) REVIEWER'S INITIALS: C C DUE DATE: 1 -30 -2001 Not Applicable LI DATE: 4111111111111•11MINimmy ANNIE DUE DATE 2-27-2001 Not Approved (attach comments) DATE: �- / DUE DATE DATE: ACTIVITY NUMBER: D01 -020 DATE: 1 -25 -01 PROJECT NAME: DR JIM SIMMONS SITE ADDRESS: 411 STRANDER BL XX Original Plan Submittal DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Please Route .11•1111101. Vxaou« oK Response to Correction Letter it TUES /THURS ROUTING: PLAN REVIEW /ROUTING SLIP C REVIEWER'S INITIALS: REVIEWER'S INITIALS: Fire Prevention Structural Incomplete LI Not Applicable Fi Structural Review Required REVIEWER'S INITIALS: CORRECTION DETERMINATION: Approved Approved with Conditions ri SUITE NO: 202 Response to Incomplete Letter I± Revision ft After Permit Is Issued Planning Division ri Permit Coordinator n n DUE DATE: 1 -30 -2001 No further Review Required % DATE: I 2.q l APPROVALS OR CORRECTIONS: (ten days) DUE DATE 2-27-2001 Approved t Approved with Conditions n Not Approved (attach comments) DATE: DUE DATE Not Approved (attach comments) n DATE: PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D01 - 020 DATE: 1 - - PROJECT NAME: DR JIM SIMMONS SITE ADDRESS: 411 STRANDER BL SUITE NO: 202 XX Original Plan Submittal Response to Incomplete Letter I _ Response to Correction Letter it Revision if After Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 1-30-2001 Complete C Incomplete ri Not Applicable Comments: .1)) .• «.arc 1 /a, t 1 rti,.'_ t '1„„t, TUES/THURS ROUTING: Please Route E./ Structural Review Required I ! No further Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved n Approved with Conditions CORRECTION DETERMINATION: Approved n Approved with Conditions REVIEWER'S INITIALS: 'JUc)UT( Do n Fire Prevention Structural C Planning Division n Permit Coordinator C n DATE: u'/ — , DUE DATE 2 -27 -2001 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: DUE DATE Not Approved (attach comments) DATE: JAN .� TUK4 PUBLIC vtio; iKs Kind of Fixture future Units No. of Fixtures Total Fixture Unite Public Prtv3ls Public Private Bathtubs and/or shower 4 2 , Dental units 1 1 Dishwasher 4 2 Drinking fountain (each head) 1 1 Hose bibb (interior) 5 3 Clotheswasher or laund tub 4 2 Sink, bar or lavatory 2 1 LI Sink, clinic, flushing 10 10 Sink, kitchen 4 2 Sink, other 4 2 Sink wash, circle spray 4 4 Urinal, flush tank 3 3 1 r Urinal, wall or stall 5 5 Water closet, tank 5 3 Water closet, flush valve 10 6 Non -' sidential Sewer Use Certr" ration (To be completed for all new sewer connections, reconnections or change of use of existing connections. This form does not apply to repairs or replacements of existing sewer connections within five years of disconnect.) Pursuant to King County Ordinance No. 11034, all sewer customers who establish a new service which uses metropolitan sewage facilities after February 1, 1990 shall be subject to a capacity charge. The amount of the charge is established annually by the King County Council but is limited by state law to S10.50 per month per residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. The charge is collected semi- annually. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at (206) 684 -1740. Owner's Name r, (Please print or type) (last. First. Middle Ionia Property Legal Address: Subdivision Name Lot # Subdiv. # Block # Prope y S eet Addres City, State, Zip Owner's Phone Number Owner's Mailing Address (if different from above) A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Units Residential Customer Equivalent (RCE) 20 fixture units equal 1.0 RCE Total No. of Fixture Units 1058 ' Rev. 2 ;00) 20 01:3 Total Fixture Units (p RCE For King County use: Account # Monthly Rate Six Month Due White - King County Property Tax ID # Building Name (if applicable) Party to be Billed (if different from owner) Party's Mailing Address: or Property Contact Phone # City or Sewer District i I Date of Connection Side Sewer Permit # D61 6 Zo Demolition of pre - existing building? ❑ Yes 1:1 No Demolition Permit # B. Other Wastewater Flow (in addition to Fixture Units identified in Section A) Type of Facility /Process: Estimated Wastewater Discharge: Gallons /days Residential Customer Equivalents (RCE): 187 gallon per day equals 1.0 RCE Total Discharge (gal/day) 187 C. Total Residential Customer Equivalents: (add A & B) A B Date Yellow - Local Sewer Agency RCE Pink - Sewer Customer RCE I certify that the information given is correct. I understand that the capacity charge levied will be based on this information and any deviation will require resubmission of corrected data for determination of a revised capacity charge. Signature of Owner/ Representative Print Name of Owner /. Representative FROM : OLYMPUS PHONE NO. : 1 425 430 5, FAX FROM: Concerning: O/vrn PHONE - (425) 277 -5444 FAX - (425) 430 -5412 w PO BOX 50082 " Bellevue, WA 9801 5-0082 Destination Fax Number: 206- `'3f. Number of pages (including the cover sheet: 1 Date sent: Time sent: To: From: URAL NH( 4 -.- .. _ :Z::V3ins CONFIDENTIAL INFORMATION intenoed only for the use of the accressee na... -: :ne intended recipient of this facsimile, or the emcloyee or agent respor.sioie for ce. you are hereby notified that any dissemination or copying of this facsimile is .:d .eiC !nos facsimile to error. please immediately notify us by Ieiephone and return ".ri : • .. _ - r Tnarx you. REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL DATE REGIST. # EXP. CCO1 DATE 22/1 0/1987 OLYMPUS CONSTRUCTION INC PO BOX 50082 BELLEVUE WA 9 Jy ii_u:dur■.; _.•_ _ \ltUl. ' • \ \i) t � t)l'� t b' u:;l h . 1►t't' : \RTNIliN't' UI: LABOR Construction, ;n .. Dec. 15 2000 10:23AM PI , 4 .4 �u�rrent C ontractor Registration Card: rs o Enter Contractor Information in. Sierra: MATERIAL SYMBOLS I. MECHANICAL AND ELECTRICAL CONTRACTORS SHALL BE RESPONSIBLE FOR MAINTAINING CO1- PUANCE WITH APPUCABLE CODES AND STANDARDS. OBTAIN ALL NECESSARY PERMITS AND APPROVALS. 2. DEVIATIONS FROM DIMENSIONED LOCATIONS MUST BE APPROVED BY THE ARCHITECT. 3. THE CONTRACTORS SHALL VERIFY THE LOCATION OF EACH CORE SWILL, PIPING, CONDOR'; ETC. WITH THE EXISTING STRUCTURE AND SHALL NOTIFY THE ARCHITECT OF ANY CONFUCTS OR OB- STRUCTIONS. ALL CORE DRILL RELOCATIONS SHALL BE REVIEWED BY THE ARCHITECT AND STRUCTURAL ENGINEER. 4. SPECIAL MOUNTING HEIGHTS FOR ELECTRICAL OUTLETS ARE NOTED AOJACEiT TO THE OUTLET. 5. DISCREPANCIEG BETWEEN EXISTING CONDITIONS AND CONTRACT DOCUMENTS SHOULD BE CAVED TO THE ATTENTION OF THE ARCHITECT. , FINISHES III III -I i I- IT -ITI� EARTH ! -- FINISH WOOD " PROJECT TEAM CLIENT PROPERTY MANAGER DR AM SIMMONS NEWCASTLE REAL ESTATE SERVICES EYE 5 OPTICAL CONTACT: PATSY ROOGERS 411 STRANDER BLVD, #202 (425) 641 -4564 TUKWILA, WA 98188 ARCHITECT PROPERTY OWNER THOMAS MEP DESIGN OR. JEROME WARMED. 22027 AVE EAST - 411 STRANGER atme., SUITE 308 SEATTLE, WA 98112 TUKWILA, WA 98188 (206) 575 -1551 206.320.9063 FAX 206.726.5974 CONTACT DR. ,EROME BARUM CONTACT: TOMESTEP GENERAL CONTRACTOR OLYMPUS CONSTRUCTION, INC. P.O. BOX 50082 BELLEVUE, WA 98015 (425) 277 -5444 CONTACT: ROBERT OSMUND PLYWOOD eo, a o e0t PROJECT ADDRESS '4 ° GRAVEL CONCRETE - -X -- '• ( 1 12: 1 - METAL STUD PARTITION •" CONCRETE BLOCK .' /' METAL (LARGE SECTION) METAL (ELEVATION) O.W B. "'''�• ' STONE // BRICK ... ,. . ;. ( CERAMIC TILE/ :Qai HOLLOW CLAY TILE .. PIASTER /SAND GROUT/MORTAR / /// \' \ / WOOD STUD WALL \ GLASS (ELEVATION) WWOOD FRAMINNG (CONIINUOUSJ RIGID INSULATION TILE /ACOUSTIC `'1 (ENTERRUPTED� (l >(l l( l( l(((. /\ Jl A /l /T l\ / WATT INSULATION ELECTRICAL SYMBOLS • 0 RECESSED UGHT €a DUPLEX RECEPT, 0 WALL - MOUNTED LIGHT W. DUPLEX ACCEPT., 4 - SURFACE /PENDANT UGHT 1/2 SWITCHED e WALLWASH LIGHT 4 FOURPLEX RECEPT. m RECESSED SPOTLIGHT 0 FLOOR ACCEPT. UNDERCABINET LIGHT 0 CEILING /SOFFIT ACCEPT. UPWARD - DIRECTED STRIP LIGHT 0 110V SPECIAL PURPOSE .0 PICTURE LIGHT W 220V SPECIAL PURPOSE 0 CLOSET LIGHT 4 TELEPHONE )8 CERAMIC SOCKET a TELEVISION 0 HALOGEN SPOT LIGHT Is DOORBELL 0 HALOGEN FLOOD LIGHT e SMOKE DETECTOR .E ADJUSTABLE FLOODLIGHTS © MASTER LOAD = FLUORESCENT LIGHT .+ SWITCH --I. TRACK LIGHT 3 -WAY SWITCH TRACK LIGHT - 2 CIRCUIT 4 - WAY SWITCH ❑ FAN /LIGHT COMBO 0 DIMMING SWITCH ® EXHAUST FAN _" TI , VACUUM CONTROL ` CEILING FAN 4 ® SPEAKER to COMPUTER ® CIRCUIT BREAKER PANEL W COMPRESSED AIR CONTROL E7 METER EXIT LIGHT NOTE TELEPHONE /ELECTRICAL OUTLETS SHALL BE MOUNTED Q) JUNCTION BOX VERTICALLY AT +12" A.F.F. U.O.N. GENERAL SYMBOLS \ di NORTH ARROW 0 DOOR # - SEE SCHEDULE 0 WINDOW # - SEE SCHEDULE H DETAIL NO, E INTERIOR ELEVATION SYMBOL 5 HEET NO. ' DETAIL NO. DETAIL SYMBOL SHEOTNQ. WALL SECTION REFERENCE /2\ SREVISION REFERENCE 4 - DATUM POINT -1 BREAKLINE MECHANICAL / ELECTRICAL I. MECHANICAL AND ELECTRICAL CONTRACTORS SHALL BE RESPONSIBLE FOR MAINTAINING CO1- PUANCE WITH APPUCABLE CODES AND STANDARDS. OBTAIN ALL NECESSARY PERMITS AND APPROVALS. 2. DEVIATIONS FROM DIMENSIONED LOCATIONS MUST BE APPROVED BY THE ARCHITECT. 3. THE CONTRACTORS SHALL VERIFY THE LOCATION OF EACH CORE SWILL, PIPING, CONDOR'; ETC. WITH THE EXISTING STRUCTURE AND SHALL NOTIFY THE ARCHITECT OF ANY CONFUCTS OR OB- STRUCTIONS. ALL CORE DRILL RELOCATIONS SHALL BE REVIEWED BY THE ARCHITECT AND STRUCTURAL ENGINEER. 4. SPECIAL MOUNTING HEIGHTS FOR ELECTRICAL OUTLETS ARE NOTED AOJACEiT TO THE OUTLET. 5. DISCREPANCIEG BETWEEN EXISTING CONDITIONS AND CONTRACT DOCUMENTS SHOULD BE CAVED TO THE ATTENTION OF THE ARCHITECT. , FINISHES 6. ALL PAINT, WALL COVERINGS AND WALL PANELS THOU_ BE APPLIED IN ACCORDANCE W RM THE MANUFACTURER'S RECOMMENDATIONS. 7. SAMPLES OF ALL FINISH COLORS SPECIFIED SHALL BE SUBMITTED FOR APPROVAL TO THE ARCHITECT PRIOR TO COMME.(TCEMENT OF THE WORK. B. CARPET CONTRACTOR SHALL FURNISH AND INSTALL RUBBER REDUCER STRIPS AT LOCATIONS WHERE CARPET AND RESILIENT FLOORING MEET. PROVIDE COLOR SAMPLES FOR APPROVAL 9. FLOOR COVERING IN CLOSETS SHALL BE THE SAME AS THAT OF THE SPAM UNTO WHICH THE CLOSET DOOR OPENS, U.O.N. 10. PREPARE FLOOR PER FLOORING AND CARPET MANUFACTURER'S RECOMMENDATIONS TO PROVIDE LEVEL AREA FOR FLOORING INSTALLATION MD LEVEL FLOORING TRANSITIONS CEILING 11. SUPPORT DATA LATERAL SUPPORT SHALL BE PRODDED BY FOUR WARES OF MIN. 12 U.S. GAUGE SPLAYED IN FOUR DIRECTIONS, 90 DEGREES APART AND CONNECTED TO THE MAIN RUNNER. WITHIN 2 INCHES OF THE CROSS RUNNER AND TO THE STRUCTURE ABOVE AT AN ANGLE NOT EXCEEDING 45 DEGREES FROM THE PLANE OF THE CEILING. THESE LATERAL SUPPORTS SHALL BE PLACED 12' -0" 0.C. IN EACH DIRECTION, WITH THE FIRST POINT WITHIN 4' -0" FROM EACH WALL 12. VERTICAL SUPPORTS SHALL BE PRODDED BY WIRES OF MIN. 8 U.S. GAUGE TO SUPPORT A MAX. 16 SO. FT. OF CEILING AND SADDLE -RED AROUND MAIN RUNNERS, PER CHAPTER 47.1812 OF THE UBC STANDARDS. ATTACH CROSS RUNNERS TO MAIN RUNNERS BY SADDLE -TYING WITH ONE STRAND 18 U.S.. GAUGE MRE, OR APPROVED EQUIVALENT, PER CHAPTER 47.1812 OF THE UBC STANDARDS. DISCONTINUOUS ENDS OF CROSS - RUNNERS AND MAIN RUNNERS TO BE VERTICALLY SUPPORTED WITHIN 8 INCHES OF SUCH DIS.CONTINUITIES AS MAY OCCUR WHERE CEILING IS INTERRUPTED BY A WALL • FIRE PROTECTION 13. PROVIDE FEE PROTECTION AT AU. PENETRATIONS OF FIRE -RATED ELEMENTS AS REQUIRED BY CODE AND /OR BUILDING. OFFICIAL " PROJECT TEAM CLIENT PROPERTY MANAGER DR AM SIMMONS NEWCASTLE REAL ESTATE SERVICES EYE 5 OPTICAL CONTACT: PATSY ROOGERS 411 STRANDER BLVD, #202 (425) 641 -4564 TUKWILA, WA 98188 ARCHITECT PROPERTY OWNER THOMAS MEP DESIGN OR. JEROME WARMED. 22027 AVE EAST - 411 STRANGER atme., SUITE 308 SEATTLE, WA 98112 TUKWILA, WA 98188 (206) 575 -1551 206.320.9063 FAX 206.726.5974 CONTACT DR. ,EROME BARUM CONTACT: TOMESTEP GENERAL CONTRACTOR OLYMPUS CONSTRUCTION, INC. P.O. BOX 50082 BELLEVUE, WA 98015 (425) 277 -5444 CONTACT: ROBERT OSMUND PROJECT DATA. . PROJECT ADDRESS 411 STRANGER BOULEVARD, SUITE TUKWILA, WA 98188 ZONING CLASSIFICATION TUC (TUKWILA URBAN CENTER) CODE INFORMATION UNIFORM BUILDING CODE -1997 OCCUPANCY: GROUP B AREA OF CONSTRUCTION: ( SQ. FT. LEGAL DESCRIPTION SOUTHCENTER PROFESSIONAL PLAZA, 411 STRANGER BOULEVARD, ANDOVER PAFK, IN THE CITY OF TUKWILA, COUNTY OF KING, STATE OF WASHINGTON, ON THE REAL PROPERTY DESCRIBED AS FOLLOWS: PARCEL "A" THE NORTH 137 FEET, LESS THE EAST 165 FEET THEREOF. OF TRACT 5, ANDOVER INDUSTRIAL PARK N0. 3, AS RECORDED IN VOLUME 78 OF PLATS, PAGES 6 AND 7, RECORDS OF KING COUNTY, WASHINGTON. PARCEL ''E' THAT PORTION OF THE SAME TRACT 5 LYING SOUTH OF A UNE 137 FEET SOUTH OF AND PARALLEL TO THE NORTH UNE OF SAID TRACT, AND WEST OF A UNE 165 FEET WEST OF AND PARALLEL TO THE EAST UNE OF SAID TRACT. PARCEL "C' THE EAST 155 FEET, LESS THE NORTH 137 FEET THEREOF, OF THE SAME TRACT 5. DRAWING INDEX A -1 PROJECT DATA / GENERAL INFORMATION A -2 FLOOR PLAN / WALL DETAILS. A -3 REFLECTED CEILING PLAN / ELECTRICAL PLAN A4 INTERIOR DETAILS A -5 DOOR, ELECTRICAL & ROOM FINISH SCHEDULE AS INTERIOR ELEVATIONS AND DETAILS GENERAL NOTES 1. THESE DRAWINGS ARE THE PROPERTY OF THE ARCHITECT AND MAY ONLY BE REPRODUCED IMTH THE WRITTEN PERMISSION OF THE ARCHITECT. AUTHORIZED REPRODUCTIONS MUST BEAR THE NAME OF THE ARCHITECT. COPYRIGHT 1999 BY REED RISING ARCHITECTS. THESE DRAWINGS ARE FULLY PROTECTED BY FEDERAL AND STATE COPYRIGHT LAWS. ANY INFRINGEMENT OF THESE LAWS WILL BE PROSECUTED. ALL CONSTRUCTION SHALL CONFORM TO THE 1997 UNIFORM BUILDING CODE AND BE IN ACCORDANCE WITH ALL WASHINGTON STATE LAWS AND REGULATIONS AND ALL CODES IMPOSED BY LOCAL AUTHORITIES. 2 CONTRACTOR'S RESPONSIBILITY: THE CONTRACTOR SHALL CHECK AU. DRAWINGS AND VERIFY ALL DIMENSIONS AND STRUCTURAL MEMBER SIZES PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL IMMEDIATELY INFORM THE ARCHITECT OF ANY DISCREPANCIES IN THE DRAWINGS OR WTH THE CODES. CHANGES INITIATED BY THE CONTRACTOR SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL ENGINEER PRIOR TO PROCEEDING WTH FABRICATION OR CONSTRUCTION. CHANGES INDICATED SOLELY ON THE DRAWINGS WLL NOT SATISFY THIS REQUIREMENT. 114 CASES OF DISCREPANCIES BETWEEN EXISTING CONDITIONS AND THE DRAWINGS, THE CONTRACTOR SHALL OBTAIN DIRECTIONS FROM THE ARCHITECT PRIOR TO PROCEEDING. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM HIS OR HER WORK, AS WELL AS BEING RESPONSIBLE FOR ALL REQUIRED SAFETY PRECAUTIONS. STRUCTURAL SYSTEMS WHICH ARE COMPOSED OF - COMPONENTS TO BE ERECTED IN THE FIELD, SHALL BE ACCOMPANIED BY SUPPUER SUPERVISION DURING MANUFACTURING, DELIVERY, HANDUNG, STORAGE AND ERECTION ACCORDING TO THE INSTRUCTIONS PREPARED BY THE SUPPLIER. 4. CONTRACTOR SHALL BE FAMILIAR WITH ANY GENERAL STRUCTURAL NOTES ELSEIW ERE IN THESE DOCUMENTS. WHERE CONFLICTS OCCUR BETWEEN THESE GENERAL NOTES AND STRUCTURAL NOTES, THE GENERAL STRUCTURAL NOTES SHALL SUPERCEDE 5. NOTED DIMENSIONS AND VERIFIED EXISTING DIMENSIONAL CONDITIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS: DO NOT SCALE DRAWINGS. 6. REPETITIVE FEATURES DRAWN OR NOTED ONLY ONCE SHALL BE COMPLETELY PRODDED AS IF DRAWN OR NOTED IN FULL 7. DIMENSIONS ARE TO CENTER LINES, WALL SURFACES, OR AS OTHERWISE INDICATED ON DRAWINGS 8. EACH SUBCONTRACTOR IS RESPONSIBLE FOR COORDINATING HIS WORK WITH ALL OTHER TRADES AND SHALL VERIFY ALL FIELD DIMENSIONS WTH CONDITIONS FOR ITEMS FURNISHED AND INSTALLED BY HIMSELF. 9. EACH SUBCONTRACTOR, AT THE COMPLETION OF HIS WORK, SHALL REMOVE ALL DEBRIS RESULTING FROM HIS WORK. 10. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE HE DOES TO ADJACENT BA.A AND SHALL MAKE GOOD SUCH DAMAGE AT HIS OWN EXPENSE. EXISTING AREAS DAMAGED AS A RESULT OF WORK DONE UNDER THIS CONTRACT SHALL BE REPAIRED AND FINISHED TO MATCH ADJACENT FINISHES. 11. EXISTING EQUIPMENTANSTALLATIONS MADE OBSOLETE BY NEW SYSTEM SHALL BE REMOVED AND THE AREA(S) PATCHED AND FINISHED TO MATCH ADJACENT SURFACES. CONTRACTOR TO CONSULT ARCHITECT ABOUT SALVAGE, STORAGE, AND /OR DISPOSAL, WHEN NOT IDENTIFIED IN SPECIFICATIONS 12. ALL NEW INTERIOR FRAME PARTITIONS SHALL BE OF NON - COMBUSTIBLE METAL STUDS, OR AS NOTED. 13. CONTRACTOR SHALL CONSULT PLANS OF ALL TRADES FOR DUCTS, PIPING, CONDUIT AND EQUIPMENT, AND SHALL VERIFY SIZE AND LOCATION OF ALL OPENINGS REQUIRED AND SHALL COORDINATE WAN TRADE REPRESENTATIVES AS APPUCABLE. 14. WALLS AT CORRIDORS AND STAIR ENCLOSURES SHALL EXTEND TO STRUCTURAL/RATED CEILING. 15. NEW PENETRATIONS FOR CONDUIT, DUCTS AND PIPES SHALL BE SEALED, AND DUCTS FIRE - DAMPERED PER SAC. 18. FRE -STOP WALLS, FLOORS AND FURRED AREAS PER SAG 17. ALL DUCTS, EQUIPMENT. :'OUTY LINES AND CONDUITS SHALL BE HELD AS CLOSE AS POSSIBLE TO STRUCTURAL CEILINGS A:: BEAMS. 18. GENERAL CODE NOTES: A. FIRE DAMPER DUCTWORK PASSING THROUGH RATED WALLS AND FLOORS PER CHAPTER 7, UBC.. B. PROVIDE SAFETY GLASS PER CHAPTER 24, UBC. C. NO PENETRATIONS OF PLUMBING OR ELECTRICAL OR MECHANICAL ALLOWED IN STAIR ENCL09 :` 'S (CHAPTER 7 le 10 UBC) D. PROVIDE EXIT LIGHTS AS REQUIRED PER CHAPTER 10, UBC. E FLAME SPREAD OF CARPETING AND INTERIOR FINISHES VERTICAL EXITWAYS LESS THAN 25; HORIZONTAL EXITWA1S LESS THAN 75:OTHER, LESS THAN 200, PER TABLE 8, A AND B. MILLWORK 9. ALL MILLWORK (WOODWORK; AND CABINETRY) SPECIFIED ON THESE DRAWINGS SHALL BE FURNISHED AND INSTALLED BY THE MILLWORK CONTRACTOR(S) U. 0. N. 20. MILLWORK CONTRACTOR SHALL BE RESPONSIBLE FOR FINISHING ALL MILLWORK IN HIS /HER SHOP. FINISH SHALL MATCH SAMPLE TO BE PRODDED BY ARCHITECT IN COLOR AND GLOSS LEVEL DO NOT ABS FINISH. 1. MILLWORK CONTRACTOR SHALL SUBMIT (2) FINISH SAMPLES FOR ARCHITECT PRIOR TO FABRI- CARON. 2. MILLWORK CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AND SPECIFICATIONS FOR ARCHITECT APPROVAL PRIOR TO FABRICATION. ARCHITECT RESERVES THE RIGHT TO REJECT ANY MILLWORK ITEMS THAT HAVE BEEN FABRICATED WITHOUT APPROVED SHOP DRAWINGS. 23. ALL MATERIALS AND WORKMANSHIP MUST BE EQUAL IN ALL RESPECTS TO THE STANDARS SET FORTH IN THE ARCHITECTURAL WOODWORK QUALITY STANDARDS AND ARCHITECTURAL WOODWORK INSTITUTE" (AWL) MOST CURRENT EDITION. 24. PLYWOOD SHALL BEAR THE: GRADE AND TRADEMARK IDENTIFICATION OF THE AMERICAN PLYWOOD ASSOCIATION (A.P.A.). PLYWOOD 3/4" THICK U.O.N. 25. ALL VENEERS WITHIN PANEL FACES SHALL BE ONE PIECE FLITCHES. SHOULD JOINTS BE REQUIRED, THEY SHALL BE END MATCHED AND /OR SUP MATCHED AS APPROVED BY ARCHITECT. 28. HAND SELECT ALL EXPOSE. HARDWOODS, SOLID STOCK AND VENEERS FOR GRAIN APPEARANCE CON- FORMING TO ARCHITECT'S APPROVED SAMPLES. SUBMIT SAMPLES TO ARCHITECT FOR APPROVAL TO SHOW GRAIN VARIATION PRIOR TO PROCEEDING. 27. PROVIDE CUT -OUTS IN MILLWORK AS DETAILED AND REQUIRED FOR ALL PLUMBING FIXTURES, KITCHEN EQUIPMENT, DENTAL EQUIPMENT, AND ELECTRICAL ITEMS BASED ON INFORMATION SUPPLIED FROM THE PLUMBING, DENTAL, AND ELECTRICAL CONTRACTORS, VERIFY ALL REQUIREMENTS PRIOR TO FABRICATION. 28. CUT -OUTS AND OPENINGS FOR ALL KITCHEN AND DENTAL EQUIPMENT SHALL FOLLOW TEMPLATES OBTAINED FROM EQUIPMENT INSTALLERS. 29. SPECIAL METAL WORK AND FINISHING ITEMS SHALL BE FABRICATED BY COMPETENT MECHANICS SKILLED IN METAL WORK. WORKMANSHIP SHALL BE EQUAL IN ALL RESPECTS TO THE BEST QUALITY FOR THIS TYPE OF WORK. GRIND ALL WELDS SMOOTH, 30. FIT AND SECURE CABINET HARDWARE PER MANUFACTURER'S PRINTED INSTRUCTIONS. EXERCISE CAUTION NOT TO MAR OR INJURE SURFACES. REPAIR ANY AND ALL DAMAGED SURFACES TO LIKE -NEW CON- DITIONS 31. GLASS MIRRORS: MIRROR - "QUALITY FLOAT GLASS, I/O THICKNESS, U.O.N. 32. ALL MILLWORK ELECTRICAL MATERIAL, WORKMANSHIP, AND INSTALLATION SHALL BE IN CONFORMANCE WITH APPLICABLE LOCAL STATE, AND NATIONAL ORDINANCES AND CODES. ALL MATERIAL TO BE U,L APPROVED. 4, GENERAL CONTRACTOR TO FURNISH ALL WOOD BLOCKING. THIS SHALL INCLUDE BLOCKING TO SECURELY MOUNT ALL CASES, EQUIPMENT, AND ACCESSORIES INDICATED ON THE DRAWINGS. 5. ALL FINISHED HARDWOOD VENEERS TO BE RIFT CUT U.O.N. DEMOLITION 35. SALVAGE PLUMBING FIXTURES FOR RE -USE 37. VERIFY LOCATION OF EXISTING WAI I S TO REMAIN MBAR TO START DE AFAR: am I/32" = NO SCALE SITE PLAN VICINITY MAP STRANGER BLVD. IST 4115 BAKER BLV RAND T - E 0 DR R BLVD. • I I I undorstand that I n C Ck approvals are -1: is . J ors and _ -,.c and approval Of i lib I ;:tans e at o the v OIA:I0n of any .:e' d code OF ordinance. Receipt of con - rsoiors copy of approved plans acknowledged. E C By Data 2 -/3 -O/ Permit No. C ` WITH ".L;l RECEIVED CITY OF TUKWILA JAN 2 5 2001 Do 1- OW EYE 5 OPTICAL 411 STRANDER BLVD, A202 A- I co TUKWILA, WA 951ER o THOMAS &STEP SLEET PERMIT CcnITER DATE ' z0 0 ABBREVIATIONS & And MAX. Maximum L Angle M.C. Medicine Cabinet ® At MECH. Mechanical ¢ Centerline MEMB. Membrane Diameter MET. Metal Pound or Number MFR. Manufacture(r) MH. Manhole ACOUST. Acoustical MIN, Minimum A.D. Area Drain MIR. Mirror ADJ. Adjacent MISC. Miscellaneous ADJUST, Adjustable M.O. Masonry Opening A.FF, Above Finish Floor MTD. Mounted AGR. Aggregate MUL Mullion AL Aluminum APPROX, Approxlamate N. North ARCH. Architectural N.I.C. Not In Contract ASS. Asbestos NO. Number ASPH. Asphalt NOM. Nominal N.T.S. Not to Scale BD. Board O.A. Overall BINM. Bituminous OBS. Obscure BLDG. Building O,C, On Center ELK. Block O.D. Outside Diameter (dim.) B Blocking CAC.I. Owner Furnish/Contractor Install SO. M. Beam SOT. Bottom O.F.O.i. Owner Fumish /Owner Install OFF. Office CAB. Cabinet OPNG, Opening C.B. Catch Basin OPP. Opposite CEM. Cement. PL Plate CER, Ceramic C.I. Cast Iron P -LAM. Plastic Laminate C.G. Comer Guard PLAS. Plaster CH. Chalk PLYWD, P CLG. Ceiling CLKG. Calking PRCOT. Precast CLR. Clear PT. Paint CMU. Concrete Masonry P.T.D. Paper Towel Dispenser CNTR. Counter P.T.0/R Combination Paper Towel C.O. Cased Opening Dispenser & Receptacle COL Column PTN. Partition CONC. Concrete P.T.R. Paper Towel Receptacle CONN, Connection Q T Quarry Tile CONSTR, Construction CONT. Continuous CORR. Corridor R. Riser CPT. Carpet RAD. Radius CTSK. Countersunk R.D. Roof Drain ACCEPT. Receptacle DBL. Double REF. Reference DEPT. Deportment . - REFR. Refrigerator D.F. Drinking Fountain REINF. Reinforced DET. Detail REQ'D Required DIA, Diameter RESIL Resilient DIM. Dimension RESIST. Resistant DISP. Dispenser RM. Room DN. Down D.O. Door Opening R.O. Rough Opening DP. Deep RWD. Redwood DR. Door R.W.L Rain Water Leader DS. Downspout S. South D.S.P. by Standpipe DW. Dishwasher S.B.C. Seattle Building Code DWG. Drawing S.C. Solid Care DWR. Drawer S.C.D. Seat Cover Dispenser SCHEO. Schedule E. East S.D. Soap Dispenser EA. Each SECT. Section E.J. Expansion Joint OH. Shelf EL. Elevation SHR. Shower • ELEC. Electrical SAT. Sheet ELEV. Elevator SIM. Similar EMER. Emergency S.N.D. Sanitary Napkin Dispenser ENCL. Enclosure S.N.R. Sanitary Napkin Receptacle EP. Electrical Panel SPEC. Specification EQ. Equal SQ. Square EQPT. Equipment S.S. Stainless Steel E.W.C. Electrical Water Cooler S.W. Service Sink EX. Existins STA. Station EXST. Existing STD. Standard WO. Exposed STL Steel EXP. Expansion STOR. Storage EX, Exterior STRL Structural SUSP. Suspended F.A. Fire AN SYM. Symmetrical F.B. Flat Bar F.D. Floor Drain T.B. Towel Bar FON. Foundation T.B.S. To Be Selected F.E. Fire Extinguisher T.C. Tap of Curb F.E.C. Fire Extinguisher Cabinet TEL. Telephone F.H.C. Fire Hose Cabinet TER. Terrazzo TN. Finish T&G Tongue & Groove FL, Floor INK. Thick FLASH. Flashing T.P. Top of Pavement FLUOR. Fluorescent • T.P.D. Toilet Paper Dispenser F.O.C. Face of Concrete TRD. Tread F.O.F. Face of Finish T.V. Televisan F.O.S. Face of Studs T.W. Tap of WaII FPRF. Fireproof TYP. Typical F.S. Full Size FT. Foot or Feet SRC. Uniform Building Code FTC. Footing UNF. Unfinished FURR. Furring U.O.N. Unless Otherwise Noted FUT. Future UR. Urinal GA. Gauge VAC. Vacuum GALV. - Galvanized V.A.T. Vinyl Asbestos Tile G.B. Grab Bar VERT. Vertical GL Glass VEST. Vestibule CND. Ground GR. Grade W West G.W.B. Gypsum Wall Board W/ With GYP. Gypsum W.C. Water Closet WD. Wood H.B. Hose Bibb W/O Without H.C. Hollow Core WP. Waterproof HDWD, Hardwood SOOT. Wainscot HOWE Hardware WT. Weight H.M. Hollow Metal HORIZ. Horizontal HR. Hour HT. Height INCL. Include(d) 1.0. Inside Diameter (Dim,). INOUE Insulation INT. Interior JAN. Janitor JT. Joint KIT. Kitchen LAB. Laboratory LAM. Lami.,ote L,V Lavatory LORD. Laundry LKR. Locker LT. Light WALL LEGEND EXIST. HALL TO REMAIN EXIST. 5/8 ON 7/8" MET. FURRING CHANNEL (VERIFY) TO REMAIN ON EXIST. GONG. HAIL REPAIR OR EXTEND 6115 4 FURRING AS REWIRED FOR NBA WORK INDICATE). EiffiiiiSEMBI NEW HALL - 2 I/2" MET. STUDS N 16' O.G. H/ 5/8' 656 EA. SIDE SEE DETAIL 4/A2.0 IEEMEMME NEW HALL - 3 I/2" 1ST. SUDS N IN OL. Wl 5/8" 6113 EA SIDE. SEE DETAIL 5 1A2A NEW HALL W/ AGOUS. INSUL - 3 1/2' MET. STUDS 6 I6" O.G. 1U HORIZ 7/8' 656156NT &HAM EL (RD-I) N 16" 0.5. I/1 THK. 50UND ATTENUATING BATT INSUL K15/8' OHS EA. 5100. SEE DETAIL 6/A10 NOTE CONTRACTOR TO VERIFY WITH BUILDING OFFICIAL AND PROVIDE REQUIRED FIRE EXTINGUISHERS. NOTE. CONTRACTOR To VERIFY WITH BUILDING OFFICIAL AND PROVIDE REQUIRED EXIT 516NAGE. EXIST. 14000 CHAIR RAIL FLOOR PLAN 00 K DOCTOR'S OFFICE 1/4" = I' -O" NOTE: GONTRAGTOR' TO FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO CONSTRUCTION. ® ALL DETAL 11/2" = I' -O" /I\. /I\ �O WALL DETAIL � 11/2" = I' -O" / EXTEND BATT INSUL \-- (-) WALL DETAIL 11/2" = I' -O" D 0(020 o THOMAS ESTEP FASTENERS 0 24" O.G. EXIST. STRUCTURE SUSP. GL6. (VERIFY TYPE) REFERENCE RCP FOR A.F.F. HEIGHTS 5/8" 6143 2 1/2" METAL. STUDS • IN O.G. 5/5" OW6 BASE AND FINISH FLOOR EXIST. STRUCTURE FASTENERS ®24" O.G. FASTENERS 5 24" O.G. EXIST. STRUCTURE SUSP. GL6. (VERIFY TYPE) REFERENCE RGP FOR A.F.F. HEISHT5 5/8" OHS • 3 1/2" METAL STUDS S 16" O.G. 5/8" OHS BASE. AND FINISH FLOOR EXIST. STRUCTURE FASTENERS 0 24" O.G. FASTENERS ell 24" O.G. EXIST. STRUCTURE 411'.SIRANDER BLVD. #202 co TUKWILA. WA 98188 SUSP. GLG.(VERIFY' TYPE) REFERENCE RCP FOR A.F.F. HEIGHTS 5/8" 6118 3 1/2" METAL STUDS ® l6" O.G. 3 1/2" THICK SOUND ATTENUATING BATT INSULATION' 5/8" 61 BASE AND FINISH FLOOR EXIST. STRUCTURE FASTENERS 0 24" O.G. EYE 5 OPTICAL r RECEIVED " JAN Z /o)1 PERMIT CENTER Tn lnc 1,1 on., SHEET A - z DATE I r/w'al NOTE, SEG. 25212. 1 -3 WTI USG VOL. III. COMPRESSION POST SIZES I /2" DIA. EMT TO 4' -O" 3/4" DIA. EMT TO 5' -2" I" DIA. EMT TO 6' -6" 2 I/2" X 25 GA. STL. 5TUD TO 6' -6" GROSS RUNNER (4) 12 GA WIRES 12LO" O.G. EACH WAY, 6-0" MAX. FROM WALL (SPLAY WIRES 10" FROM EAGH OTHER B 45 FROM CEILING PLANE) 12 GA. WIRE ® 4' -O" O.G. (TYPICAL) PROVIDE COMPRESSION POSTS AT/ OR OVER SPLAY WIRE FROM MAIN RUNNER TO STRUCTURE. SECURE W/ SPLAY WIRE TIE BOTH ENDS. MAIN RUNNER O SUSPENDED CEILING DETAIL 1 1/2' = 1' -0" REFLECTED CEILING PLAN 1/4" = 1' -0" \Z3 0H020 RECEIVED JAN 2 ?DO', EYE 5 OPTICAL 411 STRANDER BLVD. #202 oo TUKWILA, WA 98188 • THOMAS ESTEP N 220 DUI AVENUE EAST, SEATTLE, WA 206320.9063 PERMIT CENTER c•,1-0 Of AUVW10 FE9 1 "' 7.11171. S1 tiEET A- 3 DATE ZD d)