Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D01-223 - BON MARCHE - WALLS
BON MARCHE 500 SOUTHCENTER MALL • EXP1 R D FEB 1 2 2002 EXPIRED FEB 1 2 2002 D01-223 , : ',I--•Oi ;. Z Iri• :D:ot. -; 'LLI Lij1: . . • M oi - C.) • I= IS 0 City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Parcel No: Address: Suite No: Location: Category: Type: Zoning: Const Type: Gas /Elec.: Units: Setbacks: Water: Wetlands: OCCUPANT OWNER CONTACT CONTRACTOR. WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. 262304 -9086 500 SOUTHCENTER MALL ARET DEVPERM TUC Contractor License No: PUGETSB00000 DEVELOPMENT PERMIT 000 North: .0 South: .0 TUKWILA Sewer: N/A Slopes: N BON MARCHE Phone: 500 SOUTHCENTER MALL, TUKWILA WA 98188 BON;MARCHE Phone: (503) 579 -7083 C/O FEDERATED DEPT STORES, 7 WEST SEVENTH ST, CINCINNATI OH 4520 JAY LIKNESS Phone: 425 251 -1661 18832 72 AV 5, KENT WA 98032 PUGET SOUND BUILDERS NW INC Phone: 425 251 -1661 18852 72ND AVE S, KENT, WA 98032 ** *****• k*********• k**: k *•k ******•k** * *•k * *•k **•k** * *•k **• k*• kk** * * **•k* * * ****k•k * * * *** *•k*** * *k Permit Description: DEMO ,OF EXISTING NONBEARING WALLS AND RECONFIG- URATION OF NEW NONBEARING PARTITION WALLS. * * * * * * * * * ** ***•k * * * * *** ** k * * * * * * * * * * * * ** k ** ** * * * ** * ** k ** k* * * * * * * * **•k * * *•k * * * * *•k *•k *** Construction Valuation: $ 95,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut/Access/Sidewalk/CSS: N Fire. Loop Hydrant: N Flood Control Zone: N Hauling: N Start Time: Land Altering: N Cut: Landscape Irrigation: N Moving: Oversized Load: N Sanitary Side: Sewer: N Sewer Main Extension: N Storm Drainage: N ' Use: N Water Main Extension: N No: Start Time: No: Private: • *. * * *. * * * * * * * * * * *•k * * * * * *•k * ** *****************.***.****• k** * * * * * * **** ** *** * *•k *** * ** * * * *•k k* TOTAL DEVELOPMENT PERMIT FEES_ $ 1,586.44 kl o(* . * ** * * * * ** * * * ** * * * * * * * * ** * * *•k* k *** * *, * * *** * * *** k***** * * * *•k *•k * * * * * * * * * * * * * * * * * * * * ** Permit Center Authorized Signature: %sue; Signatur Print Namq ___ Permit No: Status: Issued: Expires: Streams: End Time: Fi 11 End Time: (206) 431 -3670 DO1 -223 ISSUED 08/16/2001 02/12/2002 Occupancy: STORE UBC: 1997 Fire Protection: SPRINKLERS East: .0 West: .0 Size(in): .00 Public: N Private: N Public: N e>eC se Date: -g; . 71/ I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the perfor nee of work. I am authorized to sign for and obtain this developmen . per mit. Date: g This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. • CITY OF TUKWILA Address: 500 SOUTHCENTER MALL Permit No: D01-223 Suite: Tenant: Status: ISSUED :Type: DEVPERM Applied: 07/25/2001 Parcel #: 262304-9086 Issued: 08/16/2001 ***4*************1.***A***%********* Perilltt Conditions: 1. No changes will be made to the plans unless approved by the :Engineer and the Tukwila Building- Division, , 2. All construction to be done',in ,conformanCe with approved 'plans and requirements of the Uniform Building Code (1997 Edition) as amended, 'Uniform Mechanical 'Code (1997 Edition), and Washington State Energy Code (1997 Edition). -Validity of Permit': The issuance Of a permit or approval of specifications and computations shall not be con- strued to be a permit for or an approval of, any violation 'of any of the,,provislons of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions oF this code shall be valid. Electrical:permits shallbe.obtained through the Washington ,State Division of Labor and Industries and all electrical *ark will' be :inspected by that (248-6630). • All permits, inspection records, and approved plans shall be available at the job site prior to the start of any con- , struction.; These documents are to be maintained and. avail- ' able untIlfinal inspection approval is granted. ***FIRE OEPARTMENT,CONDITIONS***" The attached 'set of plans have been reviewed by The Fire PreventiOnBureaU and are acceptable with the following concerns: All new sprinkler systems and all modifications to existing, Prnkler YSteMs-shall have fire department review and approval or:drawing:4y prior to installation or modification. New sprinkler:,systems and all modifications to sprinkler systems involving more than 50 heads sIiall have the written approval of the: Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated , and/or recorgnized by the City of Tukwila, Prior to submittal to the Tukwila Fire Prevention Bureau. No sPrinkler work shall commence without approved drawings. (City Ordinance #1901) Maintian sprinkler coverage per'N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. . The fire department connection (FDC) shall be equipped with a 5" Storz fitting(s). (UFC 1001.10) 11. Contact the Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1900 and #1901) 1 . -Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. . THESE PLANS WERE REVIEWED BY INSPECTOR 510. IF YOU HAVE NY ;.QUESTIONS, PLEASE CALL THE TU1'.WILA FIRE PREVENTION UREAU AT . (206)575-4407. hereby :. certify that I have read these conditions and wi 1 1 comply with '.them as ouutl fined.. All provisions of law and ordinances governing •'this work wi11 be complied with, whether specified herein or not. The granting `of this permit - does not presume, to give authority to violate or cancel the provisions of any other work or local laws regulating construction' or the performance Of work. • Project Name /Tenant: t„ n G '� U , e L e- - Value of Construction: ( OCR 0 Site Addre (include suite number) City Slate/Zip: . 065 C; L , t - (1G- -�„-I. 0-,-- i t/1 en. 1 ! 5 c' - � . `g /. Tax Parcel Number: 1 i, Z - ) ._ c /7f ' Property Owner: 1 l VA' ii %'V1 A (L C Lt.- Phone: If yes, extent of change: (Attach additional sheet if necessary) Street Address: City State /Zip: Fax 11: Will there be storage of flammable /combustible hazardous material in the building? ❑ yes {a -no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets Contract r: _ V'UC 4,....4 c In •-• 11 {l r` _ -cam .N .1A- , Phone: • / f2 5' 2 5 /•-/G‹, Street Addresg: �� I <6 ."?'1 J.-t0 Au .9 S City State /Zip: tea. .- - 1 43 e(-P ( . Fax 11: ` ) ' �- / ._ r 6 s :-( Architect: w % ` Phone: Street Address: ) 1 -7 1) - -. City State /Zip: / hJ. ' c Fax #: Engineer: Phone: Street Address: City State /Zip: Fax 11: Contact Person: J A .t lc v-42,2, 4 l „��,� (0 tt;l�� Phone: 92 > —25 ) — /6 6 / Street Address: j cg'' 2 ' 7 2 , - - 0 eiv-z ( • K City State /Zip: () -. cicec 5 Fax #: y2) -2 (6 ( Description of work to be done (please be specific): ., 7Jr'4'&t 1 6C-9 -» /t/V•.-.1 o[':1 .+ , r7(• !�V /z / / /T e,., / ,[ /S b4 „ ! ,-, /C1 L r /7 r° 4/ /Gri lserot /'?} -'z 7/, /in t' A' / / Existing use: - Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College/University ❑ Other ❑ Multi- family ❑ Warehouse ❑Hospital ❑ Motel /Hotel ❑ Office ❑ Other Proposed use: re tail ❑ Restaurant ❑ Church ❑ Manufacturing ❑ School /College /University Building Square Feet: 2 `iU UC existing No. of Stories: Area of construction (sq ft): 4/ YO / If yes, extent of change: (Attach additional sheet if necessary) Will there be a change of use? ❑ yes t/J no Will there be rack storage? ❑ yes 71 Existing fire protection features: ;21-sprinklers ❑ automatic fire alarm ❑ none ❑ other (specify) Will there be storage of flammable /combustible hazardous material in the building? ❑ yes {a -no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets CITY OF TU " -WILA Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 (206) 431 -3670 Project Number: ' Permit Numb ( - 22 3 Commercial / Multi - Family Tenant Improvement / Alteration Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT REQUEST FOR PUBLIC WORKS SITE /CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews may be determined by the Public Works Department) ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk Fire Loop /Hydrant (main to vault)11: Land Altering 0 Cut Sanitary Side Sewer #: Storm Drainage ❑ Street Use Water Meter /Exempt #: Water Meter /Permanent # Water Meter Temp # Miscellaneous Size(s): ❑ Flood Control Zone ❑ Hauling cubic yds. 0 Fill cubic yds. • ❑ Landscape Irrigation ❑ Sewer Main Extension 0 Private 0 Public ❑ Water Main Extension 0 Private 0 Public Size(s): 0 Deduct 0 Water Only Size(s): Size(s): Est. quantity: gal Schedule: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: 7-23 Date application expires: Application taken by: (initials) PLEASE SIGN BACK OF APPLICATION FORM 11/30/00 crperndr.dnc BUILDING 0 VER OR AUTH ,RIZED AGENT: Signature: `••„_ � f � /� Dat - __ - Print name• %� �! / Phone: Fax 14.;/ .- Addres/ g C 2 .-P S City /State /Zip APPLICATIONS MUST BE SUBMITTED WITH THE FOLLOWING: ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER D ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ t_7 Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. *Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing/grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive area and buffer (TMC •1 8.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H -9). ❑ 171 Floor plan: show location of tenant space with proposed use of each room labeled w = H . In Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of w O any hazardous materials; dimensions of proposed tenant space. < ❑ U Vicinity Map showing location of site LL ce 11 Q w El ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack N w layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of z H rack. Structural calculations are required for rack storage eight feet and over. i— 0 w ~ ❑ 71 Indicate proposed construction of tenant space or addition and walls being demolished 0 • uj D D ❑ ❑ Construction details 0 rn ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in a1- structure, i.e., roof; size of water W W supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed 1--- F O-- sprinkler system design criteria as identified by the Fire Department. - 0 Z ❑ ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. U u) O ~ ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public • Health is located at 999 Third Avenue, Suite 700, Seattle, WA or call (206) 296 - 4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building. Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this subrnittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LA WS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. 11/30/00 clperndldnc Z W Ce W J O 00 Z 4t ,,,k:A• * A- A ***:if A A -A * A -.!t. * * * * • * * * * Is A * A * * WV. • - • T R ANSA LT • • A at 7sc * *4* * *ir* * *Is..k * * * * * A * *11..k * ****..k*** INMrT 95 8 Ainotint•:' • 56'3..25 08/36/01. 12g47 vmet Me hod :1CHECit•• Notat i on pliBEI: SOUND BLDR • Init: SKS • • drn:!: - D01;7223. :; Type: 'DEYPERM 'DEVELOPMNT PERMIT ;• ?,..a1 262:23 o4...!9a86 e A d SOU(HCENE : A A LL's- • ' • •,•:•. Total Fees: :t s ••; Pynietqt • 1 963 Total ALL. Pint's: 1. 40ic # A4 *4 A 7k.1 * * ***A:* A *iv* k A * * *if* 'it: * * A it A * iv.* count • Code '..• DeLr-1.11 BUILDING -- NCINRES , 958.7Z 000/36.9 O4 STAT:E BUILDING SUR CHARnE 4..50 . 0204 08/20 9719 . TOTAL 963.25 *.A, *atlr :k 4:14 Is le *A- **kk * *k�fi * * ***A* * h• k.*- k•*A *:t. *.A**yt *•,E k4�ih':F. KWILA W y}A H,A1v5AixT *de kof',/r7 k 'A A• P *,* * k *k Zak -te fr kkh�tai;A:ir 1 ** h€ r�:. :. (SV . \�V:. r7 ' P'enm.it N.o .13 -223 T.vge.M •DE .. PERA D.EVE.LOPMEt�T.. PEIU IT . • f'� r'.ce1 Nu::262304-90E6 i te, Aitd es.s: ":U0 ap,uf HC MA L.1...' y s' t x y .. 1 o N4 1 , la ee M ' . N. Y t5 E3 G N 4 - i i s P Yme.ri. .i 9 Tot£t l '' ALL ..Pmts, a 1: 23 . 19 . • 13 a 1 s;cnr_.e N 963 „'25. *..***':•*:* a. *'1t *!t * * * * * *do* * * * **** * * * * **' A ■ A ***i: 1;:.01..10 l; Ggde pesrrip Amount. Q0 /345 l3,t? PLAN C'11EC 1< - NONRES 62 19. January 8, 2002 Jay Likness 18832 72nd Avenue South Kent, WA 98032 City of Tukwila Department of Community Development Steve Lancaster, Director RE: Permit Application No. D01 -223 500 Southcenter Mall Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Sincerely, Xc: Permit File No. 001 -223 Duane Griffin, Building Official • Call the City Of Tukwila Permit Center at (206) 431 -3670 to schedule a progress / final inspection A progress inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to February 12, 2002, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Stefania Spencer Permit Technician Steven M. Mullet, Mayor di: i....... n.`. isf::,: �i• Y.Eini:i;ff.wNi�.tnreiraxv.a ,.,.... ... .... ..w»• r.Y x'.A. ...$ S' .......... ..'kd; .iiK .. ' 6300 Southcenter Boulevard, Suite 11100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206-431-3665 ACTIVITY NUMBER D01 -223 PROJECT NAME: BON MARCHE SITE ADDRESS: 500 SOUTHCENTER MALL SUITE NO: DATE: 07 -25 -01 X :" Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # AFTER Permit Is Issued DEPARTMENTS: Bui ding Division riq - P blic Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete g Incomplete n Comments: TUES /THURS ROUTING: Please Route REVIEWER'S INITIALS: PLAN REVIEW /ROUTING SLIP Structural Review Required APPROVALS OR CORRECTIONS: (ten days) Approved V'aaou!LAOC Fire Prevention G Structural Approved with Conditions n n REVIEWER'S INITIALS: CORRECTION DETERMINATION: Approved Ti Approved with Conditions n REVIEWER'S INITIALS: Plannin�� g Division ►tile. 1 -2 (.-d1 Permit Coordinator DUE DATE: 07 -26-01 Not Applicable n No further Review Required DUE DATE 08-23-01 DATE: Not Approved (attach comments) DATE: DUE DATE Not Approved (attach comments) n DATE: DEPARTMENTS: Building Division Public Works Approved n WRROUTE.[)OC L'MI n REVIEWER'S INITIALS: PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER D01 -223 PROJECT NAME: BON MARCHE SITE ADDRESS: 500 SOUTHCENTER MALL SUITE NO: X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # AFTER Permit Is Issued DATE: 07 -25 -01 TUES /THURS ROUTING: Please Route Structural Revi REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (ten days) Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n Comments: Approved ri Approved with C. itions n Planning Division Permit Coordinator DUE DATE: 07 -26 -01 Not Applicable LJ equired n No further Review Required DATE: 7 " 26 -ax, DUE DATE 08-23 -01 CORRECTION DETERMINATION: DUE DATE Approved with Conditions n Not Approved (attach comments) Not Approved (attach comments) n DATE: e g /az' REVIEWER'S INITIALS: DATE: z 1z : re w g 00 W= J W LL, Q' = • d w Z 1- 0 z • w D 0 P- O w w . 1-- U • 0 z . U (: t= O ~ z PERMIT NO.: - VD 1 - 223 BUILDING PERMITS INSPECTIONS ❑ 00001 Progress Inspection Status ❑ 00002 Pre - construction ❑ 00003 Investigation ❑ 00004 OK to Occupy ❑ 00005 Remove Stop Work Order ❑ 00006 Follow -up ❑ 00007 Pre -Move Inspection ❑ 00050 WSEC Residential ❑ 00060 WA Ventilation/Indoor AQC ❑ 00070 NLEA Inspection/Modular Stnuct ❑ 00071 Mobile Home Tie Down Insp ❑ 00072 Marriage Lines ❑ 00090 Resteel ❑ 00095 Footing Drains ❑ 00100 Foundation Footings ❑ 00200 Foundation Walls ❑ 00250 Foundation Insulation ❑ 00300 Concrete Slab /Slab Insulation ❑ 00350 Crawl Space ❑ 00400 Shear Wall Nailing ❑ 00450 Plywood Wall Sheathing ❑ 00500 Roof Sheathing Nailing ❑ 00525 Plywood Deck Nailing ❑ 00550 Exterior Wall Sheathing ❑ 00600 Masonry Chimney ❑ 00610 Chimney Installation/All Types [ 00700 Framing ❑ 00750 Roof /Ceiling Insulation ❑ 00800 Floor Insulation ❑ 00801 Wall Insulation ❑ 00802 Exterior Roof Insulation ❑ 00803 Glazing Inspection ❑ 00815 Lighting and Controls lee 00900 Suspended Ceiling [v]� 01000 Interior Wallboard Fastening ❑ 01001 Exterior Wallboard Fastening ❑ 01110 Pre -Move Inspection ❑ 01115 Motor Inspection ❑ 01120 Pre -Demo ❑ 01140 Pre - reroof ❑ 01400 Final -Fire v❑' 01700 Final- Building ❑ 01900 Final - Reroof ❑ 03100 Site Visit ❑ 04000 Special- Concrete ❑ 04001 Special -Bolts in Concrete ❑ 04001 Special- Mom/Resist Conc Frame ❑ 04003 Special -Reinf Steel Prestress ❑ 04004 Special - Welding ❑ 04005 Special- High - Strength Bolting ❑ 04006 Special - Structural Masonry ❑ 04007 Special -Reinf Gypsum Concrete ❑ 04008 Special- Insulating Conc Fill ❑ 04009 Special -Spray Fireproofing ❑ 04010 Special- Piling, Piers, Caissons ❑ 04011 Special - Shotcrete ❑ 04012 Special- Grading, Excav /Fill ❑ 04013 Special- Retaining Wall ❑ 04014 Special - Panels ❑ 04015 Special -Smoke Control System TENANT NAME: ViaYG (i1.G CONDITIONS [0001 No changes to plans unless approved by Bldg Div ❑ 0010 Special inspection required, notify Bldg Div ❑ 0011 Special inspector shall submit final signed report ❑ 0012 New ceiling grid & light fixture shall meet lateral bracing ❑ 0013 Partition walls attached to ceiling grid ❑ 0014 Readily accessible access to roof mounted equipment ❑ 0015 Engineered truss drawings & calcs shall be on site ❑ 0016 Exposed insulation backing material ❑ 0017 Subgrade preparation including drainage, excavation ❑ 0018 Statement from roofing contractor verifying fire retardant class of roof 0019 All construction to be done in conformance w /approved plans ❑ "No work shall be done in addition to those modifications..." ❑ 0002 Plumbing permits shall be obtained through King Co ❑ 0020 Structural observation shall be provided for this project ❑ 0021 All food preparation establishments must have King Co ❑ 0022 Fire retardant treated wood shall have flame spread of ❑ 0023 Notify Building Division prior to placing any concrete ❑ 0024 All spray applied fireproofing shall be special inspected ❑ 0025 All wood to remain in placed concrete shall be treated ❑ 0 026 All structural masonry shall be special inspected 027 Validity of Permit ❑ 028 Rack storage requires separate permit 2 0003 Electrical permits obtained through L & I ❑ 0030 No occupancy of building until final insp by Bldg Div ❑ 0032 Remove all weeds, concrete, stone foundations, flat concrete ❑ 0036 Manufacturers installation instructions required on site ❑ "BTU maximum allowed per 1997 WA State Energy Code" ❑ 0035 Contact PW Div to obtain insp for water /sewer connect ❑ 0038 A C of O will be required for this permit ❑ 0039 Final approval for all TI w /in the limits of the SC Mall ❑ 0004 All mechanical work shall be under separate permit ❑ 0040 All construction noise to be in compliance with 8.2 TMC ❑ 041 Ventilation is required for all new rooms & spaces 0005 All permits, insp records & approved plans available ❑ 0006 All structural concrete shall be special inspected ❑ "Applicant shall obtain a separate plumbing permit from King Co" ❑ "Anchoring — All new construct and substantial improvement shall be anchored to prevent flotation" ❑ 0007 All structural welding shall be done by WABO certified inspector ❑ 0008 All high- strength bolting shall be special inspected ❑ 0009 Bolts installed in concrete shall be special inspected ❑ 0031 Comply with requirements of TMC 16.04 ❑ 0034 Removal of septic tanks require approval and compliance with King Co Health Dept. ❑ "Obtain required inspections from appropriate water & sewer districts" ❑ "Fuel burning appliances ❑ "Appliances, which generate...." ❑ "Water heater shall be anchored...." ❑ " Reroof' Plan Reviewer: Permit Tech: Date: 06 Date: • t ;1,4 ACTIVITY NUMBER D01 -223 PROJECT NAME: BON MARCHE SITE ADDRESS: 500 SOUTHCENTER MALL SUITE NO: X Original Plan Submittal DATE: 07 -25 -01 Response to Incomplete Letter # Response to Correction Letter # Revision # AFTER Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: PLAN REVIEW /ROUTING SLIP n Structural Incomplete n TUES /THURS ROUTING: Please Route ri Structural Review Required APPROVALS OR CORRECTIONS: (ten days) Approved n App •ve• with Condition REVIEWER'S INITIALS: 5k) V'RROUI 1.000 L'rl Fire Prevention PI Planning Division Permit Coordinator DUE DATE: 07-26-01 Not Applicable ri No further Review Required n REVIEWER'S INITIALS: DATE: DUE DATE 08-23 -01 Not Approved (attach comments) n ( DATE: CORRECTION DETERMINATION: DUE DATE Approved n Approved with Conditions Not Approved (attach comments) REVIEWER'S INITIALS: DATE: A:; t:! tti .<Ya4Y�:1Li?=, "eU %:i2'il�`w^ia c. rn''. i% G'r` ..l,:f:'•'G;ti,� z w i � O 0 WI J 1- N Li- W D J' • Q I- W z F- 0 z1 uj W 2 o. 0 o 1-. w W ; • • 0 ..z w U ( I ) H . O z DEPARTMENTS: Building Division Public Works Complete Approved WRROUIIADC SPr7 n n PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER D01 -223 PROJECT NAME: BON MARCHE SITE ADDRESS: 500 SOUTHCENTER MALL SUITE NO: X Original Plan Submittal DATE: 07 -25 -01 Response to Incomplete. Letter # Response to Correction Letter # Revision # AFTER Permit Is Issued DETERMINATION OF COMPLETENESS: (Tues., Thurs.) CORRECTION DETERMINATION: Fire Prevention n Planning Division Structural Incomplete n APPROVALS OR CORRECTIONS: (ten days) REVIEWER'S INITIALS: Permit Coordinator n DUE DATE: 07-26-01 Not Applicable ri Comments: TUES /THURS ROUTING: Please Route n Structural Review Required Li No further Review Required REVIEWER'S INITIALS: DATE: — 1 r - 0 DUE DATE 08 -23-01 Approved with Conditions ri Not Approved (attach comments) DATE: DUE DATE Approved ri Approved with Conditions n Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: t464Xti:NAMV4iWifaii6,7 6, ACTIVITY NUMBER D01 -223 PROJECT NAME: BON MARCHE SITE ADDRESS: 500 SOUTHCENTER MALL SUITE NO: DATE: 07 -25 -01 ,Response to Incomplete Letter # X? Original Plan Submittal Response to Correction Letter # Revision # AFTER Permit Is Issued. DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: 1PRROUIF.FIOC snrl PLAN REVIEW /ROUTING SLIP n ( Fire Prevention n Planning Division Structural Incomplete APPROVALS OR CORRECTIONS: (ten days) Permit Coordinator DUE DATE: 07-26 -01 Not Applicable TUES /THURS ROUTI G: Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE 08-23 -01 n Approved Approved with Conditions n Not Approved (atta h comments) n REVIEWER'S INITIALS: C DATE: 02' /o( CORRECTION DETERMINATION: DUE DATE Approved n Approved with Conditions n Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: .A 01 REGISTERED'AS PROVIDED BYLAW AS CONST:CONT GENERAL •.• •., REGIST. # EXP. DATE CCO1 PUGETSB0000Q 09/18/2001 EFFECTIVE DATE 09/18/2000 PUGET SOUND BUILDERS NW INC 18852 72ND AVE S KENT WA 98032 • • • • • NOTICE : IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR TIAAN - 1 THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. 7heBONNA(ll( GENERAL NOTES I. ALL CONSTRICTION SHALL COMPLY WITH THE FOLLGWI. CODES (LATEST EDITORS, UNIFORI BUILDING CODE NATIONAL ELECTRICAL CODE IJNFORI FIRE CODE BULLETIN 93 UNIFORJ MECHANICAL CODE AND LOCAL CODES AND ORDINANCES WHICH ARE MORE STRMENT. 2. CONTRACTORS SHALL INSPECT SITE ...RI, ALL CONDITIONS AND DIMENSIONS BEFORE STARTING WORK DO NOT SCALE DRAUT4G5. THE CONTRACTOR SHALL USE DIMENSIONS SHOUN ON THE DRAWINGS AND ACTUAL FIELD MEASUREMENTS. NOTIFY STORE PLANNING IF ANY DISCREPANCIES ARE FOND. 3. CONTRACTORS DUTIES SHALL INCLUDE A PROVIDE AND PAY FOR L LABOR MATERIALS, AND EQUIPMENT. 2. TOOLS AND MACHINERY. 3. OTHER FACILITIES AND SERVICES NECESSARY FOR PROPER .- -- QFTIOJ AND COMPLETION OF THE WORK UNDER THIS CONTRACT. B. SECURE AND PAT FOR ALL PERMITS, LICENSES AND r.. 5. C. PAY ALL REQUIRED TAXES AND LABOR D. GIVE WRITTEN NOTICE OF CHANGES OR SUBSTITUTIONS IN ADVANCE FOR APPROVAL E. ALL DESIGN CHANGES TO APPROVED BY _TORE PLANNING. WOK WITHOUT WRITTEN APPROVAL MAY BE ASKED TO :BE CHANGED AT NO EXPENSE TO THE OVER 4. GENERAL CONTRACTOR 15 RESPONSIBLE FOR THE PROPER COORDINATION OF WORK OF ALL TRADES AND TO INSURE THAT ALL FLOORING, WALLS. OFEN@Ya5. LIGHTING, VENTS, GRILLES, SPRINKLERS, CONDUITS, AND PIPPY: ARE PROVIDED FOR AND PROPERLY INSTALLED AND PROPERLY LOCATED. 5. WHENEVER FEASIBLE, CONCEAL ALL ELECTRICAL AND MECHANICAL ITEMLS N NEW CONSTRJCTION. COORDINATE ALL EXPOSED ITEMS WITH STO. FLANNG. 6. VERIFY DEPTH AND LOCATIONS OF EXISTING FRAMING. PROVIDE ADDITIONAL BLOCYJFL'- A5 REQUIRED. PATCH AND REPAIR WOW TO MATCH EXISTING ADJACBNT StINFACBS. PATCH ALL SUWACES DAMAGED OR DISFIGURED BY WORK UNDER THIS CONTRACT: INCLUDING HOLES LEFT BY THE REMOVAL OF EXISTING ITEMS OR El 11, - 1., FINISH ALL EXPOSED SURFACES. 1. WHERE WALLS ARE NOTED TO BE REMOvED, PATCH ALL ADJAC.IT WRFACES. WALLS, CEILING, AND FLOORS AS REQUIRED PER FINISH SCHEDULE a CONTRACTOR TO PROVIDE DUST BARRIER DURING DEMOLITION AND CONSTRICTION. S. CONTRACTOR I5 RESPONSIBLE FOR THE DAILY CLEAN UP AND REMOVAL OF DEBRIS BEFORE LEAVING JOB SITE. 10. CONTRACTORS ARE TO SUBMIT "45- BUILT° DRWWIIS OF ALL MODFJCATIO.B TO MECHANICAL, ELECTRICAL, SPRINKLERS, AND PARTITIONS TO THE BON MARCI-E STORE PLANNING DEPARTMENT UPON COMPLETION OF THIS JOB. II. CONTRACTOR TO PROVIDE (31 THREE SAMPLES OF EACH PANT AND FNISH MATERIALS A5 AS SPECIFIED. ALL SAMPLES TO BE REVIEWED AND APPROVED BY STO.v PLANJIN'- 12. PROVIDE SHOP DRAWUKS OF ALL PERIMETER FREE STANDR.K-. AMA MISC. cUS1011 FIX- TURES, PRIOR TO FABRICATION FOR REVIEW AND APPROVAL BY 5TO% PLANNING, 13. THE CONTRACTOR AO04OWLEDGES THAT THE WORK TO BE PERFOR'E:D WILL BE PERFORMED IN A STORE ENVIRONMENT AND THAT THE OWNER 44A5 A 1- EIG4TERED INTEREST N PREVENTING LOSSES DUE TO THEFT DURIFY THE COJKE OF THE WORK THE CONTRACTOR THEREFORE AGREES TO STRICTLY COMPLY WITH AL CF THE OWERS SECURITY REGLATIONS IN EFFECT AT THE JOB SITE. IN ADDITION THE CONTRACTOR WILL INSTITUTE REASONABLE SECURITY MEASURES TO PREVENT THEFT ON THE JOB SITE NCLUDNY_, BJT NOT Lf 1I� TO, CONDUCT., OR COOPERATING WITH THE OWNER N CONDUCT. CRIMINAL BACKC-ROND CHECKS IN ACCORDANCE WITH THE FAIR CREDIT REPORTING ACT, ESTABLISHUYs CONTROLLED ACCESS POINTS TO THE JOB SITE, PROVIDING IDENTIFICATION BADGES KR 4U1170R.D PERSONNEL ON THE JOB SITE, PROVIDING ADEQJATE BARRIERS BE1UEENR. JOB 5ITE AND REIMANDER OF THE STORE, AND TO INSTITUTE OTHER SECURITY MES.1.5 AS REQUESTED BY NE OWNER THE CONTRACTOR SHALL IMMEDIATELY REMOVE FROM THE JOB SITE ANY SUB- CONTRACTOR EMPLOYEE OR AGENT WHO FAILS TO ADHERE TO THE OI ERS 5EO11R1, REGULATIONS, THE SECURITY REQUIREMENTS INSTITUTED BY TFIE CONTRACTOR OR ANY SUBCONTRACTOR, EMPLOYEE OR AGENT OTHERWISE UNSATISFACTORY TO 01.ER 14. ITEMS SPECIFIED cN THIS PROJECT SHALL BE ORDERED WITHN TWO WEFK. GF iU-E BID AWARD TO MEET CONSTRICTION SCHEDULES. ANY EXPENSE DIE TO LNTR'EY DELAYS AND SELECTION OF ALTERNATES SHALL NOT BE TO THE OJINER. 15. ALL DESIGN CHAN'.sES TO BE REVIE.D AND APPROVED BY STO. P _ANNUa✓-. ANY WORK PERFOR'ED WINOJT APPROVAL MAY BE ASKED TO CHAIGEEO AT NO EXPJNSE TO O.•ER I6. THE INTENT OF THE DRAWINGS 15 TO SHOW GENERAL SCOPE OF THE WORK 1 AND MATERIALS NOT EXPLICITLY IMPLIED ARE !WENDED TO BE CONTRACTOR DESIGNED WITH METHODS, MATERIALS, AND PROCEEDURES TO OI N_ER 9R CR TO START WORK IN SPECIFIC THE AREA. IT GEN. NOTE- ALL DOORS ARE EXISTING AND ARE TO BE Fes- LOCATE AS eR FLAN SOUTHCENTER MALL, SEATTLE, WA. PROJECT DIRECTORY SITE ADDRESS: The Bon Marche 500 Southcenter Mall Seattle Washington 98188 contact: Mark Mason, General Manager tel: 206. 656. 6001 fax: 206. 656. 6001 OWNER: The Bon Marche Third Avenue and Pine Street Seattle, Washington 98181 contact: BILL WILKINS tel: 206. 506.1102 Fax: 206. 506. 1140 GENERAL Puget Sound Builders CONTRACTOR: 18852 12nd Ave. 5o. Kent, WA. 95032 Contact: Jayy Likness tel: 425 / 251- -1661 CODE INFORMATION ZONING OCCUPANCY: PROJECT TYPE: CONSTRUCTION TYPE: AREA OF IMPROVEMENT: CONSTRUCTION COST: OCCUPANCY LOAD: SPRINKLER SYSTEM: MECHANICAL SYSTEM: ELECTRICAL SYSTEM: STRUCTURAL; TAX PARCEL No.: GOVERNING AGENCY: The Bon Marche 5 -2 Tenant improvement Type II -N sprinkled 1,468 SO. FT. 495,000. (estimated) Existing, Fully sprinkled modification incidental to the work as noted on plans, bidder design Existing system modification' incidental to the work as noted on plan, bidder design Existing, modify, lighting to new layout as noted on plans, bidder design No structural work' 262304 -9056 City of Tukwila Department or Community Development Building Division 6300 Southcenter Boulevard Tukwila WA' 95185 tel: 206. 3510 fax: 205. 431. 3555 AREA OF RE- CONSTRUCTION 0 AREA OF REMODEL-FIRST FLOOR - LOWER LEVEL L __ SHEET INDEX 1 - COVER SHEET: NOTES, INDEX, SECTIONS, DOOR SCHEDULE, ETC. 1- 4 -D PARTITION DEMOLITION PLAN 1 -4 PARTITION PLAN 1 -4.1 3TANDARD LOCATION PLAN I -SD REFLECTED CEILING / LIGHTING DEMOLITION PLAN 1 -5 REFLECTED CEILING /LIGHTING PLAN 1-1 POWER 4 SIGNAL PLAN INCLUDING DEMOLITION 5 71_0OR COVCI PrS-PLA4- 120 CLCVATIONS WOMEN: DorLD 1 22 :LCVATIONC. WOMCNG WORLD [ gg'7A7--'fE P_ti)rtfT REQUIRED FORA pittAECHANICA LPCTRICAL I LUMBING GAS PIPING CITY OF TUKW9LA gUTLDtNG DI `AIS�ON D01 -223 EXPIRED FEe des pr TYPICAL POWER 5 SIGNAL LEGEND ° (N, (NJ < E, I I ROOK MINTED HUSBELL CASH RECSISTER TLLYST _OCK RECEPTACLE (ISOLATED c.w.o./ AND POSITELEPH?L CUTLET BOX (PROVIDE TWO RAJ- WIRE FOR FPCtE AND CASH REGISTER WIRHY - Tt'P. ALL FLOORS_ NEW B BOX LOCATED AT HT. NOTED t• -AFFJ NEW WALL •IAITEO DUPLEX CUTLET 5' OFF. (.UNLESS OTHERWISE NOTED NEW WALL FIOINTED RHINE JACK- USE I-J<5T. FHI.ES e 5 OFF. < WINLESS ORERUISE NOTED 1 i CRT CUTLET WALL MIMED. RECEPTACLE - WALL MOUNTED ISOLATED'GRDIMJ NEW WALL MIMED FOURPLEX CUTLET • • IS OFF. [ UNLESS OTHERWISE NOTED NEW FIXTURE EXISTS. FXTUR - MAY BE W"WARIED POWER' g' SIGNAL GENERAL NOTES, ALL WALL OUTLETS SHALL BE MOUNTED AT 5 AFF UNLESS NOTED OTHERWISE VERIFY DUPLEX OUTLETS() -BOXES AT THE BASE OF ALL COLUMS WHICH WILL REQUIRE ACCESS WHEN 0-ERE IS A COLUMN ENCLOSURE. '. CIfVOFTUITyIp J IjL 4 5 210 PEEX7CEMEFI FEB 1 2 2002 THE BON MfARCHE STORE PLANNING THIRD 8 PINE, 71h FLOOR SEATTLE, WA 98181 208-508-7201 WILLIAM ASSOCIATES REVISIONS 505 CC 111 F- Z o IW J =O I- 3 Oz N W 2 0 2 co) 0 co T 0 0 1] M. POLK FATE'LFEBBI ETON FILE NAME: 08140CSHT SCAE- 45 NOTED P1 RED DRAIN B 15 -01 J Alen FR YOUNG IONS 2517 ra\ -- - — = = =y II I 0 I . _1 L1 3YER PAD: 26; tETTSnE:BL`RI 7Th INFANT SOTS __ J GIRLS 1 -16 RAMPAGE PAD: 716 SF XOXO PAD: 544 SF ESPRIT PAD: S61 5F TOMMY RELATED PAD: 315 SF FR R -R 0 DELIVERr —J JR DRESSES R DRESSES Pail: 518 SF FR 1x0.4 TOPS LEA (UALL) PAD: 59 5F ■ NOTE ?LL 5TA`DAA" GN1N5 P_OR ARE 14EA1Y DIRT' (• SLOTS • Z' OLJ RCES5=, PITO WALL S' TO IO'-0' LONG U140.- 0.NLE55 OTI.ERU. NOTED/ ABBREVIATION SOEOULE PI = TiTTN' @L MR.V12 = FRi1NG RM. BHNQN EXISTING, - TO REMAN NEW FIXTURE / NEW I CON5TRUC .ICI REMOVE REMOVE /i RE- LOCATE EXISTING WALL TO REMAIN NEW WALLS NEW CONSTRUCTION WALLS VALANCE - TO BE DEMO'D. ALL STANDARDS TO REMIAN crib ARTITION TYPES,- SEE TYPICAL WALL SECTIONS DUB. •.0 -I INDICATES DOOW NUMBER ON DOOR SCHEDULE - REFER TO SHEET +9 -I O L SEE • BUBBLED AREAS FOR SCOPE OF WLTeK NOTATIOMS - SCOPE OF WORK NEW CONSTRUCTION 2. t✓E'.0 WALLS - ALIGN REM TO c.. CISITMG WALLS AS NOTED REMOVE -/ RE- LOCATE ALL FITTING ROOM DOORS / FRAMES • RELATED HARDWARE ETC. NOTE - SALES - REMOVE ALL HARWARE. S..ELV.t. FOR T- .',STALLATION Ax aR. REYAVE / RELocATE ALL VAL ANS IF POSSIBLE ) TO NEW LOCATIONS - RISIOVE / 1.-LOCATE EXISTING VALANCE LIGHTING TO NEW vW1JxE LOCATIONS - VERIFY WITH ElEvATIONS FOR NEW EXTENTS. O REMOVE / RELOCATE ALL CE, LT. FIXTURES 5ts D 1 .r- 1 -6 FOR LOCATIG NS O REMOVE / 2 -CLKaN (OR NOD l G=1!NG GRID TO EXISTING CE,. GPI SALES F.CGR ( T ) REMOVE / RE -ALIC. (OR NEW CEIING GRID TO EXISTING CEILING IN FITTING ROOMS ( REVISED AREAS) FIELD VERIFY FOR POSSIBLE HT. DIFFERENCE - O g PATCH IN NEW CARPET - 1'Ll' TO: EXISTNG TERRAZZO EDGING ETC. FOR INTERSECTIONS OF CARPET TO AISLE TILE. SEE DUG ..1-13 FOR LOCATIONS AND PNSTALLAnCN NOTATIONS. 9O A.LIC3i dLL NEW STANDARDS W UWLLS ( LAZER - LEYcL / To aD.MA®NT EMIr" coPUmar so THAr at sLCnING WILL ALIGN LEVEL / VERTICAL TPROUGNO,T DEPT. ( THIS IS CRITICAL / DO1 -223 EXPIRED THE BON MARCHE STORE PLANNING THIRD 8 PINE, TM FLOOR SEATTLE, WA 98181 208 -506 -7201 WILLIAM POLK ASSOCIATES WUINN NPoL'( 0 0 ii) ir- � �, Z n '' z W -4 w o O o x W I- N 'Z R - z 5 • pi y O Q0 c m o OQ d) : _1 y..., k H N 4 A CEILING LIGHTING LEGEND SY1130L DESCRIPTION o ,, .. DCWLGHT, ATC CEILING. 6' -0 S' -0• SURFACE TINTD" TRACK - EXISTING 6' 0 S' - 0• SURFACE min). TRACK (E) A AAA F -0' SINGLE STRIP FLUOR (El. El 4' - DOLE STRIP FLUORTE Z X 2' FLUOR ATC CEILING (E, "INDT• X N )5T -4 NEW 4' STRIP LT. SN- 132R -14 OR APPRV D. EG I GC TO VERIFY ED SINGLE L AMP NARROW FLUOR GC TO vEREI' BLD'C -. CEIL POLLR 120 OR 21N CEILING MECH. / HVAC LEGEND (El SPRINKLER HEAD 0 (E) HAVC - AIR HMIDL.. ID (E HAVC - AIR 441EDL ING II � �IIIII h • ONuss113L1FiiW mt lllsmmsil --ii I�■■■■■u■■ ■1 ■ i■ ii I MINI...o■■■ii - I Ii ■■• u o u ■u■■ ■■■u ■■m''"'■2lum! ■°_■m■°■un■■ rr umm A■m m 1111■ SEMI 'I■■ ■3'1■■ ■111 ■ ■ ■211H ■2N ■1€11■ ■®1111■■ 11300 ' ■ E MIME m ■>• ■ ■11■ ■ ■� ■■ 111111.1111 ■o■■■11110 ■ ■ ■ ■ ■ ■11f i I W MINIM H ■• ■ ■ ■ ■ ■■11JAIM H■■■■■■ ■ ■ ■ ■ ■■■11■ ■ ■ ■■■■■■ ■■ ■■■u IRIMMINIMEN111111111MEMINIIIMIIIIIMMINIIMECIIIIIMMECIIIIIIIMIECIMIIIII ■laem eemaem• eemwo \meomeeemeeeemeeeo3l■■•z1■ ®■■g IINME ■EPI m ■11 ■■ aiii Na "" ■EIO■1113 a■111EI 1IA111I�iIP OLIMEMEID ■NN•••U• ■ 1••e ■ ■11 a ed■11e''lilli000ILI CIS■■ ■ ■o E ■ ■ ■ ■■ ■ ■■ ■■ ■C eeeeee ■e■- oonol�nm■ eeeee�eeeeU■■INO■■ ■■ ■o■WEW I1 r MEN 11147 I ■•■ ■■• \■ ■I€ ■■ ■ ®■ ■P31■ ■•IIECIMII ■■N■N■■■ ■Ir ■■u■N ■11■ i ■■■11 AC ii ■ ■•\• ■ ■ ■•■■11: ■N■••il■ ■ ■N Iu■ ■•• ■11 ■ ■ ■ ■11 ■■■ ■ ■■ ■ ■ ■•• ■■•• ■OCE •Z■ ■ ■I ■ ■ ■1 11MEMMo■C ■N11■o■ 1HNM 1■■■ECIMME• ■oI ■■ I •■ ■■ 111111 ■ ■ ■ ■•■ ° ■ ■ ■ ■uuuului UCAMM•••uu••••ii ■ ■■ ■MIMMEM•P■NU11 ■•u■■ 1111 ■ ■■■ ■11■■■■■ ■u■■ ■1 11 ■I�e ■er e•e 1 ■ ■31N ■�1C ■■� ■■ammo®o■■�1 ■■omme! e . _ ■5•11i■i1N� e .1350_.■ I MMEMmAMMP\■ ■A1■ImAIMM■ ETWM •1■�I I> IMII■ ■rte,,'. a Es l ul11•11 ■ uMMIn i 1■ •■■■■11•1 N■■ EV ISa ■fiE i b Siol■ao■ E011a0■ag■e.�'li f ' lC011a0■DMCD! I - I 11111 I _A •' ■ r■ ■I7 21111■nu■ ■.7�= ; �' .::Ir ■F ■•FM_■■ 9 7Nk.?T 1■ �F !I � � =1,■Il■ ■S. - , : • i1 1■ JI i�IIJ■ ■001 in 1a■•so 1110 1.>,,-■r:■' = , °■I a � _ l _RIB-•- :w■•I NW..., Alb. ■MILVIIIMAIAREIVE MID' dN M■M• 25M ■O■■=ME■ IMMi •iie rMCCC■M■M :11 - 'I■ + i■2111■ ■31N ■MCNIIHZN ■Z HZ• ■•2 ■ ■[ICIIII ■ZII ■ ■EIMPI G I■I IIIII ■■■■■■IMI00■■ ■o■N ■■■■I111■1110 ■ ■ ■ ■ ■ ■■■■ ■■Pal 111/ 11. ■ ■uu ■ ■ ■■■N■ 1111 ■ ■ ■N ■u■ ■=1u ■ ■ ■ ■ ■ ■••••= 11 IENF ■•N■• ■ ■N■ 11111 ■■u■NN■•1111M611■■•■•■ ■ ■ ■NN111 1111 ■ NM= HMI 1■ ■■M=IIZ ■11■IAN■ZI■■11II■ ■ ■MINEMI 1 ■11 ■Z■I\'! >e\• /I■ ■ ■■■N■■■■ ■N■■N■■NN■ eu ■■ ■u ■ ■ ■i•■ ■ ■■►ta I■.1■ 11•■u ■■P\ ■o■■ ■uo ■V \■■■I ■IICN ■ ■P\ ■N■RA m , ®a ® G.1■17NN■ N■ ■■■ ■ ■ ■■ii■NI ■=ID ■■1ANI ••••1'fii va,D .oxre Ncat IME RZN ZEINIZ ■NZ ■ ■■I ■■■ZIMMN■®. 211111 ■311■ IV TO .M. , a 111 '1■■ ■ ■1111I■�■■uN•NNNNN ■ ■ ■ ■ ■ ■ •u N■■■■■ s IIL [ ■■• ■■ ■■■ ■ ■ ■■UN■uNN■■I ■eHIM ■■ ■■NNUI©■ a ; ommum3;ueemue aoemo ■immomm• ■ ■m ■ommagmE ■um ■Ia ■■ II ■■iMuOa ■■OM■ CIS ■ ■LIC: ��1IIII I■PPI - CY7 ■N11+�1 H■/1' N EMI" �r1�7■ ■01:2 Q LI . liilia:71•11e 21■■CTM■■■■12■■ !I. ►. amra e 131.1 •ee nen eoeeeaoaee■ ■ ■N■•m Ig1 H21II ■C ■ ■uMN■ t MI MI ENIII ■aC7,m■ ■I■■■EN ■Z■i ■■� 11D• riliNN■n■ I• s ■o N II� ■■■■•11• ■ ■ ■ ■ ■C ' ' ____ --- r t ■ ■ ■■Nl i iili Pz ' Y -J Q 1IAuZIECIAE Zd•■M•■ ■21•//111 w 1� ■ NNU■■QIiil® ■IIIM■ ■■N■I/1■' L 111■ r2•■ N ■f ■NCI 'r1■• ■ZN ■E■ ■ ■3 PIE/ 11•� I I■11.■� NII ■■■■■u ■N� 41•11 i i�'N■ r'H■©E' I II Ii ";£u■Z ■■■CW ZI1C1C<13 ■Min mra _-^a wag '.^ =-' 11111■ ■®■ I ®I■ I i =I "1� .,6f 4 IG I 1 r1 ' _ idll IP IlP■uANI Y■ ■�e. 1:3 IC IuN•u Nr ■•••NNNNN/1:11 It 113Eu■3PN■3 €■NIE ■u3aN II III 11 ii ••au■N■N■N■u I II IC i®■■ ■■N■N■■■■■ III NI -IN, C Ii •IIH3F ■•■ 11111• av m SI Ili N��■N■■MINEZP SI ��� I■ M..," IiEEO ■ •NI f n. ^nom' AG E b SF ri] DI REV'S I FIL= Nom- 08140RCP06 -D DATE- 1 -I6 -01 NOTE= ( N , = NEW TO MATCH EXISTING FIXTURE r C 1 =' DEMO / RELOCATE (R R / = REMOVE AND /OR RELOCATE SCOPE OF WORK ITEMS', FOR ( CONSTRUCTION / DEMOLITION SEE BI✓BBLED AREAS FOR SCOPE OF WORK NOTATI VERIFY ALL JOESITE 'CONDMONS DRIERS... ETC O DEMO ALL WALL V ALANCE S, F A L .7 AS NOT CEILOYaS AND STPoF' LIGHTS IN ALL AREAS AS NOTED SEE NOTE 0 REMOVE'/ RE- LOCATE EXIST( G,vALANCE STRIP LTG. 2X2E 4D TRACK LIGHTS AND FIXTURES AS NOTED VERIFY W/ POWER AND SIGNAL PLAN f DIG 2 -1 I FOR LOCATIONS OF ALL VALANCE `J• BOXES AND RELATED EXISTING ELECTRICAL TO BE RELOCATED. - PATCH AND NEFIWSH TO MATCH ALL ADJACENT SURFACES. O VERIFY ALL EXISTIT HvAC AND 'SPRINKLER 1-EADS FOR PROPER CLEARANCE TO MODIFIED AND/ 'OR NEW CCNSTRICITON ALSO SEE REEL PCUER A'm SIGNAL PLAN DWG •1 -1 NOTE: EEL GRID IN F. R1S. TO BE RE -MOVED �- INSTAL XISTING ( CI E POSS TO ALlcaa EXISTING LIGHTIN TO REMAN D01 -223 EXPIRE TH+E BON M. --RC1E STORE PLANNING TNIRD s PINE, Ttn FLOOR SEA-LE, WL. 92181 206 - 506 -1201 WILLIAM PO ASSOCIATES l REGb'EREO ( I ut S E cr rTh L IGU-ITING FLAN LEGEND SYMBOL TYPE D.A.R2.1 - eT4 "INDY' No. 5Ni- 8212-SSE (48 "> S.,. LAMP OCTRON wECTRONIC STRIP L. FIXTUF S TO BE N 48' ...TT.- 120 VOLTS 1 -3211 OCTKGN 3500K A DUAL LAMP WIDE STRIP VALANCE LIGHT WITH AS7hP7ETRicAL REFLECTOR FIXTUFS TO BE UN 24 ", 36', 484 AND 56' La.,. - C0 'VOLTS °IND7° NG. SW-2I iR -HT( -457 (24' LAWN, 'IND, Nic. SW 222.R 1-111 ASY 36• LENGTH: TOT" No.. 81I- 232R-141I -AST (48' La.., "ND, No. SW- 2808 -HTI ADEN IA, LENGTHI 3500K- TYPICAL 2 -1811 OCTRON 2 -2. CGTRCN 2-32W OCTRON 4 -32W OCTRON ❑ F2 "ND, 'NO 2B - -282 2 )C ELECTRONIC DEEP CELL RECESSED FLUORESCENT FIXTUR FOR ACCFST. T. GRID CEILING- 120 VOLTS - C4NITE FNISH /NO 'r41_ / (2) U -BEND T8 FLUORESCENT LAMPS 3500K 'NDY° NLO. QI50T. Q- FAMILY Rama BACK TRACK LIGHT 500T WITH LLHITE FNISH - CO VOLTS 60W / PAR 38 38AHIR/SP -10 T-1.1-• AN "IN DY" No. 10U -35 COMPACT FLUORE.V1T WALL., TRACK FIXTURE WINITE FN1514 - CO VOLTS 0/ F35BX I I ® TUFT "ND, No. 11412 -40- 558 -FF COMPACT FLUORESCENT RECESSED WALL WASH / ACCENT LIC-TT FOR GYP. BD. CEILING INSTALLATION (24" LENGTH) - IDS• SPE T -04 - CO V0 r5 COMPACT FLUOR DULUX FT 40DU530/R - S ® WU "Mr' No. 11481 -40 COMPACT FLUORESCENT RECESSED WALL WASH/ LIGHT FOR ACOUSTICAL TILE CEILING INSTALLATION (24' LENGTH) - EDS.: ^It - FDS;,Tl -03 - U0 VOLTS COMPACT I FLUOR 3 L FT 40DL /8V830RS 0 FF -1 "NDY' No. 8436R1- SAC/825 FLUSH ADJUSTABLE ACCENT L., FOR GYP O. CEILING - 1220 VOLTS 60W / PAR 38 FAR / SP TO 0 pl "INDY" No 8436121 -SAC FLUSH ADJUSTABLE ACCENT LIGHT FOR GRID CEILNC CO VOLTS &OW / PAR 38 HIR / SP 10 Q .44 "NDY• No 401RV825 FLUSH ADJUSTABLE ACCENT LIGHT FOR GYP. BD. CEILING- - 120 VOLTS 601U / PAR . HIR i 5P IO 43 pa "MY" No_ 40E21 RUSH ADJUSTABLE ACCENT LIGHT FOR ACOUSTIC TILE CEILNG - 120 VOLTS SOW T FAR 38 HIR SP 10 O Gi "INDY" No. 6188- 321 -5A / 825 PLT ELECTRONIC COAX, .ELECTOR DOIINLIVAT COMPACT FOR GYP. BC. CEILING - CO VOLTS 32W RT / 4 PN 3.YJ0iC O ,F4 ' NDY• No. 2203R- 81- SA/825 RECESSED OPEN REFLECTOR DOANLIGHT 1001.'1 P AR 38 HIRTNEL o ILL, "LIGHTRONN• No. UJ i (W/ UPLIG4T/DO(LNL DIFFUSER) SURFACE MOUNTED FLUOR WALL SCONCE AT FITTING ROOM MIRROR (8' ARE/ -120 VOLTS (U 37W PLT ER-1 EXISTING RELOCATED SINGE TUBE FLUORESCENT LIGHT FIXTURE (STOCK AREAS) - RE-LAMP ALL FIXTURE EXISTING ❑ R RELOCATED IXISTNG SURFACE MOUNTEDIFLUORSCENT LIGHT FIXTURE ALL FIXTURES TO BE RE-USED AND R- LAMPED I ") 40U VAX WIT.# ELECTRONIC BALLAST 3.0K ❑ ER-3 RELOCATED EXISTMs.RECE55ED 2,0 FLUORESCENT LIGHT FIXTURE IN ACCOST. TILE CLG. - ALL FIXTUR5 TO BE E -USED AND RE- LAMPED (3) 40.1., BIAX WITH ELECTRONIC BALLAST 3500Y.- TYPICAL ❑ Et-8 RELOCATED EXISTNG RUSH MOUNTED FLUORESCENT LIGHT FIXTURE ALL FIXTURES TO BE RE- USED'AND R' -L AMPEO- CONTRACTOR TO FABRIC A NEW 48' SQUARE.; TRIM PANEL TO MATCH EXISTNG CONDITIONS (3) 40W BIAX WITH I LECTRGNIC BALL-.Td', 3500 K - . - . - . - . EXISTNG TRACK LIGHT FIXTURES AND TRACK TO BE RE -USED AND RE LOCATED EASING I ITT' X I IQ" XI" ACRYLIC LLHITE PARA.. II LOUVER "AMERICAL LOUVER COMPANY N/A ❑ EX EXISTING 24" RECESSED. FLUORESCENT LIGHT FIX1U2F'WITH 4' PANEL MOUNTED TO EXISTING PLASTER CEILING EXISTING ❑ . EXISTING 24" SQUARE SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE MOUNTED TO DUSTING PLASTER CEILING EXISTING n F EXISTING 24" X 24" RECESSED FLUORESCENT LIGHT FIXTURE IN ACOUSTICAL ' EXISTING STAIRS 111 iER PLATER GYRED. • (. 11'-8 "4'FF.) l / -6" OFF. EXISTING NEE) H H MP, I TT TILE AFF. NEUT EH■z r nan ri Y _ ■m. 6'LF7© Y „ _ . r Y wu 1 °���, AMmr. R l ea ��i� Il�uI P ••L I _� ©1rina ���I,-�®'- - ®D®r��Vi l TM .4 MI AI • � =o0i0• ®i 3)Wl 1 Jr :ru\ 37 3F1 z ®31 F GEiuuiii i ® . i � J. � r � B1 9®2 iP 31 37 2 l F . z ®. 31■ ASTER ERs . II , ,I,,B°aFE,I �IYIIDL EXISTING E^•' - - E N I j T � T . 1r It lliENE fi f . I I -1 1 IF.� I T' • 1 L ® ♦�� dICM 1• —zwilel IiivAn......m...._ _ 7 UNE 7 iiiiiEllailr GYP. 23 T � - _imiEN /a��iii -ice �i�,Ol 4,E M .1r J®JIrJQ mr .•■ 2m��r ® ®!KJ°E®RIEM ®■� 0 1110 12. ZII I Z z .... ■E . - I �. .Lr :�o:':� - ._. Br ■1•�l�iirlll®9�ir9idd f111 1 � 1 _ 11 11 D��-I I !. 1 "NI Mr ill. ME CON - SPLINE ( I 0' -P 1 8' -0" IXISTNG PL �1R I.ACOLZT T1 1 8• -0 EV.iSTNC- GENERAL LIGHTING NOTES 2 . ALL NEW TRACK TO BE "INDY" - STANDARD T- SERIES. CONTRACTOR TO RE -USE ALL EXISTING TRACK AND TRACK LIGHTS WHERE POSSIBLE - ALL TRACK LIGHTS TO BE RE -L AMPED. REFER. TO "TR' ABOVE FOR LAMP SPECIFICATIONS. ( P_AATER I 1 -5 in- Y EXISTING 2X2 ACOL'ST. TILE PLASTER 5' - m" i, EXISTING EMI OCIMEEIN bp- GSM EUJ 2X2 PLASTER ACOIIST TILE EX�Si ING- LIGHTNG T O REMAIN SCOPE OF WORK NEW CONSTRUCTION O SEE • BtbBLED AREAS FOR SCOPE O=11 TdC NOTATIONS NEW WALLS - ALIGN NEW TO EXISRRG WALLS AS NOTED REMOVE -/ FE- LOCATE ALL FITTING ROOM DOORS FRAMES RELATED HA DWA E ETC. NOTE : SALES AREAS - REMOVE ALL HAFW3ARS, 51ELVRY FOR RE- NSTALLATION AFTER frOVE / RELOCATE ALL VALANCES F 1086101E VA N E L.419. - FEMDVE / VALANCE L CA TE D08T pfG VALANCE LGMING r0 NEW vAL.Y -K'E OC1.naY %ERFY WITH ELEVATIONS FOR NEW EXTENTS. Rf_/ EMOVE / RELOCATE ALL COL_ LT. MXRIRES 5 N RT • REMOVE RE-LOCO, 0,3 • REMOVED - O RUCTURE/� M -RT • MEW TO REPLACE REMovE, 6 E0_ SPEC ABOVE (S) FEMME' /FE -ALKNr OR NEWT CEITNG GRID TO EXISTRG CEILING CN SALES FLOOR Ff]'ki c / FE -AL. OR NEW .7 CEIRG GRID TOE ..a CEILING IN FTTTSE ROOMS r REVISED AREAS) FIELD VERIFY FOR POSSIBLE HT. D - RAT. IN MEW CARPET - MATCH EXISTING TERRA.° EDGING ETC. FOR INTERSECTIONS CF CARPET TO AISLE TILE SEE DUG. -S FOR LOCATIONS AND INSTALLATION NOTATIONS. 9O ALGN ALL NEW STANDARDS IN WALLS r LA2ER - LEVER. ) TO ADJACENT EXSRRG CONDITIONS SO THAT ALL SLOTTING WILL ALIGN LEVEL / VERTICAL TNRCU.DR DEPT. THIS IS CRITICAL ) O D01 -223 EXPIRED 111 1 LK ASSOCIATES `j` :.' REGS1EP.fu _..I si 6 Z 0 0 0 W Z X 0_ Z 0 W �) Z 0 W 0 W OZ Z =o, 43e TYPICAL POWER AND SIGNAL LECE11 N FLOOR DUPLEX OUTLET © w 1 9: HUBBELL CASH REfdSTER T'''''''' flECEPiACLE pSOLATED GRDLVID) ® w FLOOR P.O.S /PHONE OUTLET BOX RROWOE TWO PULL AWES FOR P AND CASH REGISTER W 49-1 WALL MOUNTED DUPLEX OUTLET CH WALL MOUNTED JUNCTION BOX WALL MOUNTED AT'SEKE r DUREX OVTLEi - MOUNi AT NI AFF 41 WALL MOUNTED TELEPHONE OUTLET POWER AND SIGNAL GET&FAL NOTES I. ALL WALL OUTLETS S :iL BE MOUNTED AT sr AFF UN.ESS NOTED OTHERWISE 2 ra R 'CR-P';01?; - DATED T 6 AT SPEC BOOK FOR CASH WRAP CONFIGwiATION .tT- 6 -AFF FOR ,- FOR VALANCE LT L55 FEENTELECR5 RF6NT Born RAMPAGE PAD: lib 5F XOXO PAD: 544 ESPRIT PAD: 661 SF JUNIORS R: 10,100 S.F. P: 11,413 S.F. FS :99045 FR 1096 ST - a9A A N5r AFFI FOR J -130M, LEVI (WALL, FO .63- AFF R UBOX F :593.3 ST 659.1 •83' AFF FOR J -B0 THE BON MARCHE STORE PLANNING THIRD 8r PVIE, 7th FLOOR SEATTLE, WA 98181 208 -508 -7201 WILLIAM I Vigil ASSOCIATES FILE NAME: 00140RU01 SCALE: VW DRAMs BT: eW DATE: -16 -01 EXTEROfl WALL SALES SUPPORT 4273 426 FOCAL WALL OUTLETS TO BE DETOURED BY FEDERATED. CATE SALES ALERT SYSTEMS M. BLOCK ABOVE ; 1 . THE CEILING N EAR THE — Fl! _ T - Fl T T B 1.1110111111111111 I� BO HE L ) SEE E10BLED" AREAS FOR \ SCOPE OF WORK NOTATIONS D01 -223 EXPIRED SCOPE OF WORK DEMOLITION & NEW CONSTRUCTION L!W WALLS - •' NEW t0 EXISITING WALLS AS NOTED MAN-ES -/ ELATED ALL FITTING 80011 DOORS FRAtES A RELATED FIARDWARE ETC: NOTE : SALES AREAS' - REMOVE ALL HARARE. SHELVWG FOR RE- INSTALLATION AFTER • REMOVE / RELOCATE ALL VALANCES IF POSSIBLE ▪ TO NEW LOCATIONS - REMOVE / RE= -LOCATE EXISTING vALANCE LIGATI. TO NEW vALANCE LOCATIONS. VERFY WI•u ELEVATIONS FOR NEW EXTENTS O 126'10vE / RELOCATES ALL CEIL LT. FIXTURES - SEE DWG ', FOR LOCATIONS 0 REMOVE / RE-ALIGN V OR NEW) CEIING GRID TO EXSTING CEILING ON SALES FLOOR 0 REMOVE / RE-ALIGN (OR.t�EW 3 CEIING GRID TO EXISTING CEILING lm FRTM's ROO'15 f REVISED AREAS) FIELD vERET FOR POSSIBLE HT. DEER... - O PATCH G N 7J.. F CARFET - MATCH EXISTINGP ET TO ZZ0 EDCPJG ET4 FOR MTERSEDTIONS CFCARPET TO AISLE TILE: SEE. 09 '1 -5 FOR LOCATIONS AND INSTALLATION NOTATION, 9O 4LIC3N ALL I:EUI STANDARDS M UALLS ( THAT - LEVEL TWI ADJACENT EXSRMG CONDITIONS 50 THAT ALL SLOTT ING WILL ALIGN LEVEL /VERTICAL THROUGHOUT DEPT. THIS Is cwnca_ ) ' / - x nmz1 FYLSTRW, I FFrrn r�I To NFW uaLLL GONDrzlDNs i O • 41 W n O O _ L r • Z o 0 CO L,1 co e s co J ■