Loading...
HomeMy WebLinkAboutPermit 6323 - Boeing #14-01.1 - Shop FenceII -N UBC EDITION (year 1988 SETBACKS: N._ S — E- © No W- (through Public Works) FIRE PROTECTION: OSprinklers 0 Detectors 0 N/A UTILITY PERMITS REQUIRED? 0 Yes ZONING: BAR /LAND USE CONDITIONS? 0 Yes (I ) No CONDITIONS (other than those noted on or attached to permit/plans) PHONE 544 - 2975 ADDRESS P.O. Box 3707 M/S 46 -87, Seattle, WA ZIP 98124 -2207 USE y / J (01)1 PROPERTY OWNER Boeing PHONE 544 - 2975 ADDRESS P.O. Box 3707, M/S 46 -87, Seattle, WA ZIP 98124 -2207 CONTRACTOR Boein: PHONE 544 -2975 ADDRESS P.O. Box 3707, M/S 46 - 87, Seattle, WA ZIP 98124 - 2207 WA. ST. CONTRACTOR'S LICENSE # N/A EXP. DATE N/A ARCHITECT Boeing PHONE 544 - 2975 ADDRESS P.O. Box 3707 M/S 46 -87, Seattle, WA ZIP 98124 -2207 USE y / J (01)1 (Or,1Pl Inrlc'I- FLOOR V SQUARE FEET OCC. LOAD SQUARE FEET a OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD TOTAL SQUARE FEET TOTAL OCC, LOAD TOTAL CITY OF TUKWILA Dept. of Community Development- Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 BUILDING (J23 PERMIT NO. DATE ISSUED: DESCRIBE WORK TO BE DONE: Add and revise 8 foot shop fence. BUILDINU PERMIT 8620 E Marginal Wy S (POST WITH INSPECTION CARD AND PLANS IN A CONSPICUOUS BUILDING : PERMIT FEE:.: PLAN.CHECK FEE BUILDING SURCHARGE OTHER:: TOTAL -. 91 90< <; I PLAN CHECK NO.: 90 -445 J 10,100.00 ASSESSOR ACCOUNT # 000740 - 0033 PROJECT NAME/TENANT Boeing #14 - 01.1 TYPE OF U New Building U Addition () Tenant Improvement (commercial) U Demolition (building) 0 Grading/Fill WORK: 0 Rack Storage 0 Reroof 0 Remodel (residential) 0 Other: APPROVED FO ISSUANCE BY: CERTIFICATE OF OCCUPANCY NO. SIGNATURE: ` % C -few'/ PRINT NA 'N/g s,/•/ � e9iP.' /c ' BUILDING OFFICIAL DATE ISSUED: DATE: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of lay and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. DATE: / / 4 2 ,/ 4 COMPANY: 7Z e /i''l (3 117 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT NO. • CONTACTED La' r �� DATE READY DATE NOTIFIED 1 1 ` ciQ (inI1 —.L f PERMIT EXPIRES 2nd NOTIFICATION BY: AJnl I AMOUNT OWING ! 3RD NOTIFICATION BY: 111 BUILDINC#PERMIT APPLICATION TRACKING PR T NAME PLAN CHECK NUMBER co -L' INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". BUILDING SQUARE FOOTAGE/OCCUPANCY INFORMATION (to be filled out by Plan Checker) DEPARTMENTAL REVIEW "X" In box Indicates which departments need to review the project. ate sato .v IRE PROTECTION: tJ4 SwInkien fl D.tocton rl N/A FIRE DEPT. LETTER DATED: I ► I L7 10 INSPECTOR: < ►:4 BUILDING - initial review FIRE O PLANNING O PUBLIC WORKS O OTHER g BUILDING - final review SITE ADDRESS 1 t REVIEW COMPLETED INIT: INIT: ‘]3o6 n9 I4-OI S(DQ3 E mury'inal Gi293 It - ) s pIZ, SUITE NO. PROPERTY OWNER ee• L u :: a c s I' PHONE PHONE EXP. DATE 4 . 5____ ZIP • : 124 -2207 ADDRESS P.0 is. I u I . -: . • 8 Y • A a ' CONTRACTOR fC)FTNC; MTT,TTARY AIRPLANES 1 _61_544 - 2925 ZIP 98124 - 2207 _ ADDRESS P.O. ROX 3707. M/S 46 - 87, SEATTLEL WA. WA, ST. CONTRACTOR'S LICENSE # ARCHITECT POFTNC; MTLITABY ATRPJ PHONE f 2Q() 544 - 297 1 98124-2207 83].24- 2.207 _ ADDRESS P.O. BOX 3707, M/S 46 - 87, SEATTLE, WA. I HEREBY CERTIFY ..H.AT IHAY.::..A. AND EXAMI ION AN KNOW THE SAME TO: BE • TRUE AND CORRECT; 'AND:I:'AM �AUTHORiZED TO. APPLY FOR THIS PERMIT :: BUILDING OR OWNER AUTHORIZED AGENT SIGNATURE v DATE 10 -23 -1900 '�- PRINT NAME TERRY BENNT:TT PHONE (201 ) x,414 - _ CITY /ZIP 9812 ADDRESS P.O. BOX 3707, M/S 46-87, SEATTLE,WA. CONTACT PERSON TERRY 13ENNL' "r PHONE ( : i4 - 7: CITY OF TUKWILA Department of Community Development - Building Division 6200 Southcenter Boulevard, Tukwila WA 98188 (206) 433 -1849 HANSON JOB 14900941 -02 SITE ADDRESS SUITE # 8620 E. MARGINAL WAY SO. BLDG. #14 -01.1 PROJECT NAME/TENANT BOEING MILITARY 1'r'PE OF Now Building C) Addition WORK: ( .) Rack Storage 0 Reroof DESCRIBE WORK TO BE DONE: ADD AND REVISE 8 FT SHOP FENCE BUILDING USE (office, warehouse, etc.) OFFICE /MANUFACTURING NATURE OF BUSINESS: WILL THERE BE A CHANGE IN USE? k No U Yes SQUARE FOOTAGE - Building: BUILDING PERMIT APPLICATION FEES (for staff use only) Tenant Space: BUiLDING:P.ERMI.1':'FEE4 PLAN. :CHE010'FEE> >> BUILDIN(3s`SURCHAR ENERGYSURCHAR :;:;pry.: >. >::; RCPT # DATE.: ]b fp-9 0 VALUE OF CONSTRUCTION - ASSESSOR ACCOUNT it Area of Construction: 000740 -0033 C Tenant Improvement (commercial) U Demolition (building) 0 RemodolLresidential 0 Other: IF YES, EXPLAIN: 10,100.00 WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? No 0 Yes IF YES, EXPLAIN: APPLICATION SUBMITTAL In order to ensure that your application Is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide moro detailed Information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Dupatuni.int of Community Development prior to application submittal. Contact the Permit•Qoordinator at 433-1851 prior to submitting application. In all- cacoc, a.valuation amount should be entered bylhe applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined In Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 433-1849. DATE APPLICATION ACCEPTED I DATE APPLICATION EXPIRES 10 Ob L-i-arci COMMERCIAL N ........................... • '•:•••••••'"?.:,":,•:..; • • PoinPfotOd building pomiit nppllcaon , ore TWO (2) 01 tholollowtn Eli SP4C1fCatJQn$ ;•• . . ••••,:.• • • Structural - en9lnoor :::'•:.::.•.•••••• • } Soils roport staMPOd by a Washington Sttx'flconso • : . RESIDENTIAL SUBMITTAL CHECKLIST NENY SINGLE-FAMILY PWELLINGS/AD.DITIONS , .:* .•':•:i. ' • * Oomplotod twildng pormit application lOno tor pact) structuro) • • ... . . . j Lrioal puon Assossor Account Numbor . • : [1 Two sots (2) of worlung,Orawinws,:•.Whic1.11pclu • Situ plan • Foundation • Floor • Root plan 5 • Buildng olri0.§.6.514!).Y.!r ' Building cross BocUon Structural :100190 plans Washi State' Energy . Complotod Pit1)1 A show 1pg .. . sots of s,,,, • silo Plati.Odch°61c4kitY!fs;lto p lan May ba cQmblnod See ..?k4 N° B r u"ct ap ng pIicarion . " ..,. , , ri :„ uu mft , . 6o.r etcldtional topographical and soils in.lorp,7,! a y jrcid if uniq r,itu conditions. ' COMMERCIAL TENAIIT IMPROVEMENTS Comploiod ' Plleatidn ....... •■• • • • • • • r. • Cross ....... . . .................................................. ............. ..... constructi on ........................................... . ................. . .................................. of attachment .; • //ijecin• . • ; .. : • .................. utility permit • h o and plans submit sepa rate u :Rgt3 stru : • • •• • •• • ...... .. g 'matonal 668 E* A cvrilt1ca;IoqIottorls required prior to final Inspoc&op and iqn ••••,. •.; „•,..• • „ •: • - .0.. .o pa.r ANTENNNSTELUTE DISHES • • • • -. •Aossor Account Number . • •••• so o wail) tenant • • , " OrtilriilmonStonik.Or; building or square foo tage • 0"i ,•••'•".••••••••••„:. ; • • gross aniint.,;siii use . 61 ouch room xli do • ••••••)''';••••••':•••••••••,', sti wails, o •'''' •••'" • • :••• . • • ';'•••••::;. wInti.O of antonnoisatollito dish) I; Sj Wctiii n . • .. • .. • .. • . ... ••:.C 0 osso off of thopkr; ' for pooh • Stiticturo or • : • • • : . • . • . „ . ••• . • . •"• • ". • • ''•;:' ••. -,:.•••••••••••••••':. sat'aiiitOdlih:Pnd method of attathrtiont • • :•. ••• *. . by a Washington Stab 0 licensed • • (ono for each Ltructuru) • :a••lication (Onoloroach structuro). • • ;.: 4 4.0... ig 1109 romovod, and N 9 009,, ' ••*', . • ottOr 44';oeitiliisd prior to final Inspection and sign- ' Sprinklers: ..:� Fire Alarm: k Hood & Duct: Al %.4-•"4 ef.e.• Authorized Signature City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Project Name Address t /,4■ t� Needs shift inspection TU1 WILA FIRE DEPARTMENT FINAL APPROVAL FORM 1/ Retain current inspection schedule 1/ Approved without correction notice Approved with correction notice issued Halon: N' Monitor: .4 Pre-Fire: Permits: II. ,3/z. ir> f e6- ) , P Permit No. (..13 Suite # rG , :/ — Date Gary L. VanDusen, Mayor Control No. 9D-‘ FINALAPP.FRM T.F.D. Form F.P. 85 Project: �rp _ -- / ° .- � � Type of Inspection 7" Address: Date Called: Special Instructions: Date Wanted: "cf� am. p.m. Requester: Phone No.: ❑ Approved per applicable codes. c INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ❑ Corrections required prior to approval. if - ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (206) 431 -3670 R No.: Date: CITY OF TUKWILA 6200 SOUTHCENTER BOULEVARD, TUKWILA, WASHINGTON 98188 Plan Check #90 -445: Boeing #14 -01.1 8620 E Marginal Wy S PHONE M (206) 433.1800 THE FOLLOWING COMMENTS APPLY TO AND BECOME P T QQ ,,THE APPROVED PLANS UNDER TUKWILA BUILDING PERMIT NUMBERJJ . 1. No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 3. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 4. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy. Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for , or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. Gary L. VanDusen, Mayor "X" REQUIRED INSPECTIONS PHONE APPROVED INITIALS CORRECTION NOTICE ISSUED 1 Footings 431 -3670 2 Foundation 431 -3670 3 Slab and/or Slab Insulation 431 -3670 4 Shear Wall Nailing 431 -3670 5 Roof Sheathing Nailing 431 -3670 6 Masonry Chimney 431 -3670 X 7 Framing 431 -3670 8 Insulation 431 -3670 9 Suspended Ceiling 431 -3670 10 Wall Board Fastening 431 -3670 11 12 13 R 14 FIRE FINAL Insp: 575 -4407 15 PLANNING FINAL 431-3670 16 PUBLIC WORKS FINAL 431 -3670 X 17 BUILDING FINAL 431 -3670 CITY OF TUKWILA Department of Community Development - Building Division 6200 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 SITE ADDRESS: OTHER AGENCIES: BUILD'NG PERMIT INSPECTION RECORD (Post with Building Permit in conspicuous piece) SUITE NO.: BUILDING � a3 PERMIT NO. PROJECT: 8620 E Markinal Wy s Boeing #14 - 01.1 CALL FOR INSPECTIONS A LEAST 24 HOURS IN ADVANCE (INSPECTOR COMMENT SECTION ON REVERSE INSPECTION PROCEDURES AND REQUIREMENTS All approved plans and permits shall be maintained available on the site in the same location. 1. FOOTING - When survey stakes and forms are set and rebar is tied in place. 2. FOUNDATION - When forms and rebar are in place. 3. SLAB - If structural slab or if underslab insulation is required. 4. SHEARWALL NAILING - Prior to cover. 5. ROOF SHEATHING NAILING - Prior to cover. 6. MASONRY CHIMNEY - Approximately midpoint. 7. FRAMING - After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping is in place. 8. INSULATION - After framing approval, but before installation of wallboard. Baffles must be installed to keep attic ventilation points clear. 9. SUSPENDED CEILING - Fasten diffusers, lights and seismic bracing. 10. WALL BOARD FASTENING - Prior to taping (see UBC Chap. 47 and Table 47G). 11. 12. 13. 14. FINAL FIRE INSPECTION - Contact Fire Department for their requirements. 15. FINAL PLANNING INSPECTION - Contact Planning Department for their requirements. 16. FINAL PUBLIC WORKS INSPECTION - Contact Public Works Department for their requirements. 17. FINAL BUILDING INSPECTION - When all work, corrections, reports and other inspections are complete. Plumbing (including gas piping) — King County Health Department — 296 -4732 Electrical — Washington State Department of Labor and Industries — 277 -7272 A preconstruction meeting with the Building Inspector may be scheduled prior to starting the job by contacting the Department of Community Development, Building Division at 431 -3670. Although not required, a meeting of this type can often eliminate problems, delays and misunderstandings as the project progresses. 05/ IMO "X" REQUIRED INSPECTIONS 1 Footings 2 Foundation 3 Slab and/or Slab Insulation 4 Shear Wall Nailing 5 Roof Sheathing Nailing 6 Masonry Chimney X 7 Framing 8 Insulation 9 Suspended Ceiling 10 Wall Board Fastening 11 12 13 X 14 FIRE FINAL snap: 15 PLANNING FINAL 16 PUBLIC WORKS FINAL y 17 BUILDING FINAL PLAN CHECK NUMBER 90-445 PROJECT: 130M(t'1t (, THE FOLLOWINI COMMENTS APPLY TO AND SECOME PART OF T141 APPROVED PLANS ,;N3E4 TUKWILA BUILDING PERMIT NUMBER ter lflfl No changes will be made to the plans unless approved by the ��•.J Architect and the Tukwila Building Division, O Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296 - 4732). Electrical permit shall be obtained through the Washington State Division of Labor and Industries and all electrical wori will oe inspected by that agency (B72-6363). O All mechanical work shall be under separate permit through the City of Tukwila, x.[/71 All permits, inspection records, and approved plans shall be �./ posted at the job site prior to the Start of any construction, (:) when special inspection is required either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being Inspected. O All structural concrete to be special inspected (Sec. 306, UBC), "`��` -��� All structural welding to be done by W,A,B4O, certified welder and special inspected (Sec. 306, UDC). All high - strength bolting to be special inspected (Sec. 306, USC). O Any new ceiling grid and light fixture installation is required to y meet lateral bracing requirements for Seismic lone 3. Ljft') Partition walls attached to ceiling grid must be laterally braced w if over eight (81 fest in length. 12 Readily accessible access to roof mounted equipment is required. Engineereed truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. 11 Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 13 Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given in the soils report prior to final inspection (see attached procedure.). O A statement from the roofing contractor verifying fire retardancy of root will be required prior to final inspection (see attached procedure). All construction to be done in conformance with approved plans and requirements of the Uniform 'Wilding Code (1988 Edition), Uniform Mechanical Code (1918 Edition), Washignton State Energy Code (1989 Edition), and Washington Stae Regulations for lamer Free Facility (1919 Edition). O All food preparation establishments suet have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296 -4787, at least three working days prior to desire inspection date. On work requiring Health Department approval, it is the contractor's responsibility to have a set of plans approved by that agency on the job site. 19 Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear 5dentification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 20 Notify the City of Tukwila Building Division prior to placing any • concrete. This procedure is in addition to any requirements for special inspection. Z1 All spray applied fireproofing as required by U.I.C. Standard No. 43.1, shall be special inspected. ( 2) All wood to remain in placed concrete shall be treated wood. 23 All structural masonry shall be special inspected per U.S.C. Section 306 (a) 7. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for , or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provtsio of this code shall be valid. Dear Sir: City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Fire Department Review Control Number 90 -445 (512) Gary L. VanDusen, Mayor November 27, 1990 Re: Boeing Company Building #14-01.1 — 8620 East Marginal Way South The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 3302(d)) Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. (UFC 12.104b) Exit hardware and marking must meet the requirements of Uniform Fire Code Sections 12.104 & 10.402(a). Exit signs shall be installed at required exit doorways and where otherwise necessary to clearly indicate the direction of egress. Signs shall be of a contrasting color with the surrounding area and shall have letters not less than six inches high with a minimum letter width of 3/4 ". (UBC 3314) (UFC 12.108) Exits shall be illuminated at any time the building is occupied. An emergency system shall automatically provide exit illumination upon failure of the main power supply. (UFC 12.107(a)(b)) 2. This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575-4404 Any overlooked hazardous condition and /or violation:of the adopted Fire or Buildi,ng does .not imply approval of such: condition or violation. e Tukwila Fire Plan Review PROJECT 30EtNG 1 4- Q t ADDRESS 8 (0 2.0 �„ MAMaN_ A DATE OCCUPANCY GROUP . 1� z MAli!►u A -rU f& 111 t. TYPE OF CONSTRUCTION ' LOCATION ON PROPERTY BUILDING HT. / NO. STORIES L A FLOOR AREA OCCUPANT LOAD --1S.1.41 EXITING REQUIREMENTS IL) , NOTES: WY. 5 CITY OF TUKWILA DEPARTMENT OF COMMUNITY DEVELOPMENT prepared by: PI ANNINf: fIVI.VInN PLAN CHECK NUMBER 10 1/40ttiteMeAssi DETAILED REQUIREMENTS OCCUPANCY TYPE OF CONSTRUCTION PART V, CHAPTER 23, U.B.0 W.S.E.C. CHAPTER 51 -10, W.A.C CITY OF TUKWILA 6200 SOUTHCENTER BOULEVARD, TUKWILA, WASHINGTON 98188 November 8, 1990 Terry Bennett, Boeing Company P.O.Box 3707, M/S 46 -87 Seattle, WA 98124 -2207 RE: Boeing Bldg. # 14 -01.1 Plan check number 90 -445 Sincerely Ken Nelsen Plans Examiner PHONE H1206)433.181)0 Gary L. VanDasen, Mayor Dear. Terry; Please provide a complete floor plan to scale with the following information. 1. Plan must show all exit doors, interior, exterior, existing and proposed. This will help determine number of exits per U.H.C. chapter 33. 2. Plan must identify all corridors and /or passageways. This will be used to determine travel distance, distance between exits, etc., per U.H.C. chapter 33. 3. All adjoining rooms or space must be label for occupancy use so they can be classified per U.H.C. table 33 -A. This will be used to determine occupancy loads, exiting questions through adjoining spaces, and result in computing exit requirements of doors, corridors, or passageways from above comment. Contact me if there are any questions on these comments, 8 :30 . a.m. to 4 :30 p.m. at 431 -3670. BDEI K)G- 1(4• pco33 000N TE• IA noon DOOR • DOOR II-3A DOOR DOOR ODOR • ODOR • Cc) • LE; _L.- 6.2 h.14 6.2 _ _ " r _ _ .4 _ 6.4 7.2 .7.4 1 • I • Turonfien ----- - - :t - ; ----- --_---..-_-_-------- • • 0 • I - _ . Ef.4 0.4 . 9.2 • • TRANSPORTATION AISLE 1, 101 LANEI I I T I I I I I i 1 ; DEN • _ 3A.zww■www■ , L • I - • .- L •- -- 1 RNIONIIIIilic 1611 211 I I . • I I I I ' I - I - I 1 T --'- ' I I . I I I I / - I - I 4 9.4. 9.4 _ - • - • - _ - • _ - - - - - • . . - . - - - - • • , - - _ • _ - • • _ • _ - _ .. - - - ^ _ - ■ . . - • _ - - _ _ - - - • • - _ - - - - - - _ . _ - - - - - _ ■ • - - . • ■ _ - , - • • ■ - - ■ _ , - • • - • - - - - _ - - - • • - , • - ■ • . - - • • - • - . - • - _ - _ . - . _ - - _ • - • - _ ■ _ . - - - - • _ - - _ - - - - ■ . - , . _ ■ - • - _ - - _ _ - - _ - . _ - - • - - - _ _ • _ • • - - _ _ - _ - - - _ • _ - - • - • - - • • - - . - _ - --- • - - . - - - - - ■ - - - _ . • • • . • - _ ■ • - _ - _ _ - _ • _ _ ■ . • - - - ■ - - . _ - - - , - _ - _ - _ - . • , • - - - - - - , ■ . - • • - . ■ - - - • • - • - _ - . . _ _ • _ - - - , • . - - - ■ _ ■ - - • _ - ■ _ • - - - _ - - - _ ■ • _ - ■ • _ - - . . . . -- _ - ■ , _ • • - - • • - • - _ , - - - - .- I 0 ,. 1 I 2 3 4 5 6 7 8 •'i• 1 ' 1 1 • I • 1 I I . 1 • 1 I l • I • I • 1 • I • 1 III ` 1 • ' 1 . • I • I • 1 • i • i t .I 7 1 ••4.1 • , I ■1 • r • 1 . ) • I • 1 • I 1 • I • 1 • o • i • • 1 • • 1 • • I • 1 • •.1•,•1 ,•i., 1 , .t.t.... .. A . , . , -• • __ _ ____ _ I ,,, ,,,-•••'.••" .-- . IF THIS MICROFILMED DOCUMENT IS LESS ' _..- t ; :: ... c CLEAR THAN THIS NOTICE, IT IS DUE TO • ; r=TrOffrfffmx !WM!! !ON! LI® FLEXIBLE RULER - 302 AW7 oe 62 Be L2 92 SZ E2 22 12 OZ 61 01 LI 91 SI 01 CI El I. 01 Ifild111111 ildfill 6111116111 1 111 1 1 6111hidldilldHillinihillInid111161h11110 1111 1111111111111111 10.2 10.4 NH WEIS.,•7° 11.2 11.4 / x 1 HI 12.1 CO 11.2 11.4 12.2 (1), 12.4 I i 1 1 , I I YEN 12.1. _ T 13.2 13.4T T 14.2 14.4 SNOW. 1 ,„ 11 13.2 13.4 WOMEN RESTROOIA/•MOWER 14.2 TRANS•ORT A TION AISLE (FIRE 1,1110 \„, • 14.4 • 15.2 15.4 TO. I MIN • 041; iFn 15.2 15.4 rtt. •E6 1. • - :I I - - I "' - 1E ._ I I I L 16 16.2 18.4 / g .4. T C., 16.2 16.4 ertg oownrallnafik z .=-•••=•• -- ra•. i I I I _ 9.2 0 1 0 l YEN O 0 C D .9.2.. II i 10.2 10.2 10.4 I I 10.4 - • II !11 X I III 1 1.2 1 1.4 Q 12.2 12.1 7 II I r-a1u - ; - - 12.4 -- - - 12.1 e-.) .® 11.2 : - .. 11.4 - 12.2 12.4 • L- - ( i T • 13 ufR 13.2 lnow X4 • YEN I _ . .. 13.2 13.4 I WOYI4 ![4T ROOY /INOW[4 /- 1 12 Q 0 Q ON 14.2 14.4 T1•10 RORT 4 TION AIWA 1,14E 1. AND) I 14.2 14.4 L:0 15.2 15.4 • r I \ 0 0 0 Y[ I _ -! I ! u 0 ••,AE,RRR 1' 2 3 4 5 6 t - : r.--, 15.2 15.4 I'I' �''I''I''I''I 7 8 FLELIOLE RULE!) 302AW.. ".. - . OE 6Z BC 2 9Z GZ 4Z CZ ZZ tZ oz 61 01 LI 91 GI 41 CI ZL LI i i I I I I I I I I I I I Il luulnu Iluhlu IIII�IIII ulduu lUlllm uD6D] mllul UHnD Uldull I mdIIII�IIIIIIII IIIIIIIII IIIIIIIII IIIIIIIII IIIIIIIII IIIIIIIII I IIIIIIIII IIIIIIIII IIIIIIIII IIIIIIIII 1) C 18.2 18.4 • f, I 1 n ( ; Li 1 I O 18.2 - 16.4 Lam- ��✓, l. 'L LL S.`U • Y l 7 J h 17.2 • 17.2 IF THIS MICROFILMED DOCUMENT IS LESS . CLEAR THAN THIS NOTICE, IT IS DUE 10 THE QUALITY OF THE ORIGINAL. DOCUMENT 17.4 17.4 18 111.2 O 18.2 . 10.4 T 10.4 . 9 0004 E -24 DOOR I - 3 DOOR E -4 1166! E•4* DOOR E•3 0-04 I -e DOOR Edo 14 -D1 - m4�-- BUILDING NIQUTAY L . ' ril�l�l•�1!llt+ j.t - :.•L T r y r ... - '141:2 . I • I r- I - 11 l : .' ._ . I: . :) I • : • . ;i. i ' • - ,I I . ' ... .,- .70 ..... ... ... -.. OFCANEd i ' r -� -' a - .C71(1E1UK , • LAA)4ry- .,.y. ' DRAWING INDEX SHEET N0. SHEET TITLE SHEEP NO. SHEET TITLE T - t TITLE SHEET E -33R REMOVAL, 208V POWER, 9.2- 12.4/C -1 A -3R REMOVAL, ARCH. MASTER, 1ST FLR. E -37R REMOVAL, 208V POWER, 9.2- 12.4 /D -E A -8R REMOVAL, ARCH. MAS1ER, 1ST FLR. E - -57R REMOVAL., 277 -480V POWER A -7 ARCH. MASTER, 1ST FLR, 6- 9.4 /D -E E -31 ELEC. MASTER, 4TH FIR, 12.4- 19 /B - -t A -8 ARCH. MASTER, 1ST FLR, 9.4- 13 /D -E E -37 ELEC. MASTER, 1S1 FLR., 9.2--- 12.4/D- 1A19 ARCH. MASTER, 1ST FLR, 16.2- 19 /D -E E -59 ELEC. MASTER, 1ST FLR, 16- 19 /D -E 1A500 ARCH. DETAILS M -1 MECH. MAS1ER, TRENCH, 13- 16.2/D -E M -1 MECH. MASTER, TRENCH, 16.2- 19 /D -E M -23 PIPING PLAN, S.E. CORNER SYu LOCATION MAP PUGET SOUND REGION RI NSCn 111 1)0 [3 APPROVE I, _J Stu 1 1 520 BELLEVUE 201 NG M [ Y 4=O V AC IN I' 99 14 -01 OEING DEVELOPMENTAL CANTER 9725 EAST MARGINAL WAY SOUTH SEATTLE, WASHF' 98108 7 -127 IDNO COUNTY AIRPORT ENTICE CENTER (FAA) uY FROM SEATTLE- TACOMA AIRPORT VICINITY MAP PROJECT SITE E9 T 9, 99 AJPP10VE:0 FROM DOWNTOWN SEATTLE EAST UAHG'NAL WAY CORPORATE PARK DEVELOPMENTAL CENTER 0A 1E l . I . I I. I . I , I . I. 0 ,. , ,„V. 1 2 3 4 1 5 FACILITIES DEPAR f _4Uh 900 EXIT 158 N FROM KENT & AUBURN NO SCALE L_ J EAIT 157 900 6 r l€N�U7AW 7 n•_ 8 �e FLEXIUEE � lu • OE UK ON L2 ve oe 92 CZ KK IL 0Z 81 Al LI 91 RI VI CI El II ot 111911111111111111111111111111IIIIIIIII1IIII1IIII1IIII111111IIIIIIIII1IIII1IIII1IIIIIIIIIIIIIIIIIII1IIIIIIIIIIIIIIIIIII1IIIIIIIIIIIIII1IIII1IIIIIIIII1IIIIII111111IIIIIII1IIII111111IIIIIIIII1II111111II1 1 D� l L1 AUBURN, WA. 98002 [ICVERETT, WA. 98201 LI KEN T, WA. 98031 1 =1 [IORTL AND, OR. 97220 f -1(2EN TON, WA. 98055 Cg `.SEATTLE, WA. 98124 � AREA MAP L _I BLDG. ADDRESS: 8620 E. MARGINAL WAY S. SEATTLE, WA. PROJECT SITE 14- 01 BUILDING LOCATION IF TIIIS MICROFILMED DOCUMENT IS LESS CLEAR THAN THIS NOTICE, I T IS DUE 10 THE QUALIFY OF THE ORIGINAL DOCUMENT o � NO SCALE LAND USE CODE BUILDING CODES OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREAS: BUILDING FOOTPRINT BUILDING GROSS 1ST FLOOR 2ND FLOOR 3RD FLOOR 4TH FLOOR BUILDING HEIGHT STORIES OCCUPANT LOAD; ACCEPTABIUTY Ou5 OE40N ANO /DD 51'CCYIICAIION 15 APPRDYCD AMyl0VCD 00 DEPT. 0 DRAWN OY DAZE b tt 1 10. q 1 L__ .J L J 1 ( HANDICAPPED REQUIREMENTS FIRE PROTECTION SEISMIC ZONE DESIGN LOADS: ROOF - SNOW ROOF - LIVE FLOOR - OFFICE (LIVE) FLOOR - DEAD FLOOR - MECHANICAL & STORAGE FLOOR - STAIRS AND CORRIDORS WIND LOADING 5501111E 11111: TITLE SHEET ) f CODE SUMMARY TUKWILA 1988 UBC, WASHINGTON STATE ENERGY CODE, WASHINGTON STATE BARRIER FREE CODE AND ADDITIONS PER CITY OF TUKWILLA GROUP 8, DIVISION 2, OFFICE & FACTORY TYPE II, NON- COMBUSTABLE 220,514 S.F. 319,046 S.F. 220,514 S.F. 32,844 S.F. 32,844 S.F. 32,844 S.F. 60' -8' ROOF 4 NO CHANGES TO GRADE BARRIER FREE FULLY AUTOMATIC, F/S CLASS I 3 25 PSF 20 PSF 150 PSF 20 PSF (PARTITION) 125 PSF 150 PSF 80 MPH, EXPOSURE C eL �,- ER,CA.. �F Apc , L 1C A31k PROJECT TITLE D.0 SPRINKLERS THROUGHOUT FILE COPY I,I1d,I ,I,II111 Ilk!! No I'I,IO Check „II ,wyvi I w r nU, S .1 MI 0111ISS10I,S .1110 dppl oval 01 I IIIS dUI•S IIOI ,Illil,OC, / e Illy V.,IIIOO UI ,Illy : piled code 01 ur,ILOeOCe Receipt 01 C01, .copy ep1l UwOIpldns„jkntwIOdUed H LG 9t �� ?� L Hellllll NU RECEIVED CITY iF 1 11015110 PERMIT CENTER 1051 11Y41X1 — stl100E 511EC1 JO, N T -1 DAIL 900 107-21/.04 -11.)1:') ACCEPTABILITY THtS DESIGN SPECIFICATION IS APPROVED sr AND/OR APPROVED 5410.41.,. / i b' Le- SUIMELE FLOOR PLAN LAST REVISION Chock DATE :Huy kill Of 1731171, DEPT. DA ' 40/AFP . . 10 iiii ARCHITECTURAL MASTER BLDG.I4-01. I APPRO'VED APPROVED • DWG NO COL. 6-9 4 /C-D D.C. 114 Pr !IL / ( 6 • _ I ( 6 2 , J\ 941 1/6r- 1.1611-01\)1m REVISJON iv APPI1OVED DATE 1 (64 r- ' REVISION c „ 7 72 (74 --F-- i I I H I ilt1 ( - i - 1 \ I i ! , 1 , , 1 , . _ )_. [ I , - 1 '.."" It.; •' IGI :,, : 1 1 1 E KU • •• . • , Iv APPROVED DATE \M (1941 /pi\ /!, 4 5 IA Pil (AO (pAi6 . 1 H •-= 2 lifs174FIAIW FACILITIES DEPARTMENT 4f -L.) T1 14o 1' I,, r. • . ''', ' I 1 I r> , I 1 1 / :1 i 1 , , FIRST FLOOR PLAN 10 '41 SCALE : I /8" = I1-0“ 111. sr- o' AUBURN, WA. 98002 CI EVERETT, WA. 98201, KENT, WA. 98031 El PORTLAND, OR. 97220 RENTON, WA. 98055 SEATTLE, WA. 98124 00 an New 7/43 I ' t ' 1' 1 ' 1 ' 1' 1 1 ' I ' • i' I' o ,,,,.. ... ,.. 1 2 3 4 5 6 7 8 FLETIIBLE WRIER 302 RWT 0€ b 8. L 9. Se cz ze Ii 0? 61 01 LI 91 SI Cl 21 11 01 N 11111110111111111116111111111111011111111111111111111111 — r • 1 , N1'01/ '01 ATT. 1 L. IH61 (8 / A 4 114 •D :4 1 ')0 1 -A 1 • 7 0.0" - IF THIS MICROFILMED DOCUMENT IS LESS CLEAR THAN THIS NOI ICE, II IS DUE TO ri THE QUAL I IV OF ITIE ORIGINAL DOCUMENT • 9 ) 0 • 3 ti4r-oul-10 I-- --- Ill (9.2 ) - 4, 71.' -0' I I 4 , I I ; ; ; (9 4, A-4 A-7 A — I A2 KEY PLAN SCALE: 1 . 1,, V ,• 11 • ? q. I / A ....: C.. A T. T/. I r• . , • e" W1M,Z'-'7 I t 5 g.M.H WAI-T-. IZ.E.410Vr. I WW, 7" 14 04"A HAW. 4. H 1-1° Own25414.104-. 2.5p.,A mi-154-5. I&VA Wit; rAt151- 1 A 1 A 1 A A -C) RECEIVED CITY OF TUKWILA OCT 2 ti 1990 PERMIT CENTER 5 • • SYM Y M PMP •yE 115 V /AU Elf VISION 94 — K x— x— x— x— x- -x —x —x SY I0 A I APPSOVED DATE 5 Y i✓ 10 r —x —x 900991 VAi tt U(nµTNII K, 5R21KE I* , 4 .02 9 SEVISION • SY 31T L •. S rr�Ll•nr� APPROVED s,T DATE b - i i6 LI =' mac✓ JJ(�t,p — /._.." .� • X I FIRST FLOOR PLAN SCALE : 1/9 I -0 1 1 �'I I I III ' I ., 1YI ,_L, I II .1 1,I I I,,I1 1 0 . .,„.„ 1 2 3 4 5 6 y .1 ] - ❑ AUBURN, WA. 98002 ® ®E ®AW El EVERETT, WA. 98201 FACILITIES DEPARTMENT Cl KENT, WA. 98031 ❑ PORTLAND, OR. 97220 ❑ RENTON, WA. 98055 • SEATTLE, WA. 98124 I 7 ELEMIDLE - RULER 302.4W,,.,.,A -. • al. QE bZ RC LZ 9? SZ 4Z EZ ZC IC OZ 61 UI LI 91 SI VI CI el II Q1 IIIII�IIIIIIIII�IIIIIIIII�IIIIIIIII�IIIIIIIII�IIIIIIII�IIIIIIIIIIIIIIIIIIIIIIIIIIII�IIIIIIIII�IIII�IIIIIIIIIIIIII�IIIIIIIIIIIIIIIIIII�IIIIIIIIIIIIIIIIII�IIIIIIIII�IIIIIIIII�IIUINII�IIIIIIIIIIIIIIIP 11.4) a,., .- 1,1 ZU 1 - U I - ....._- M 1 - -_ 14.x' r,,,•dfZof;'jI )� • r ACCEPTABILITY THIS DESIGN ANDA3P SPECIFICATION IS APPIIOVED APPROVED IV IF THIS MICROFILMED DOCUMENT IS LESS 1 -'i CLEAR TIIAN THIS NOTICE, II IS DUE 10 It THE VUALIIY OF IIIE ORIGINAL UOCUMENI ? OI mil •.uJEF; u _:1 (TT1' Az u `: Pb't _ it / . ;-; /AJ u � _L - J 7C ; r S. LOGr(..Fp DEPT. IT GRID . APPROVED APPROVED ALI.I, y� 20:112., 12. ' 3 ,L1 7 I7.1-omcp.e. ?i•LS•GIa , b 1. - i TITLE O I I i IL J I I�174r �J / I / /I 1 SUITITLE _ ° a.,= A.. Ila'oUl•I 4 BLgG.14 -01.1 r A-. (13 A-3 FLOOR PLAN 5 C O F-i ST R U CT C IO N rCU N ! O �� TES L - 1 17 1=54-4M- l i) F Ui31 -. SLIDIHG 8 WIDE 61ATE. REMOVE NWIPE- 5U9It- 1616A1 IZWOV - 3 1 q1 FENCE 00-154-4, fia5r*. R51 2' WIPE 1 FAHSL 1:?; RE V. 2 FENCE TAI-1E1- ¢ Pa+51 KE-41, V. Z'' L'o" WIDE ? W f1 1EL YosTS, ® R - M Q V t % I.3' WI I f tA1iF - i i3. ® MoV>r !o'WIC 51- IDIH61 6A 20 Fv.tiova 1'180 WIPEi -IGE PANEL 4 RxT4. I1 SLID - P54 - te. 1 HEI-5. r J. •a,2. -c '.t "J JI v P.'/ _A 14. (. ` /LJ S I /A•_ 1/009 � / /�,,. -, I /h,_.- e ) 11 ./,I U 1 • LI ij r l3 A-4 KEY PLAN SCALE: I 20' ARCHITECTURAL MASTER 03L.9.4 -13/ D -E D.C. LEGEND A -2 A-5 I A -6 li, A -9 A (E1) RECEIVED CITY 0E 1UKWILA o C I , L; 119n PERMIT CENTER LAST REVISION I EYMSOL DATE SHEET DWG NO A-8 of 114 - 1037 <• 0 l !ii'ior.: i7711gaswsm'nrriri REVISION ,It 8/4045-00 oG,o /eV Soo /:.:54 - 02 c100 I -OZ raw 3.17-88 4 23.10 1 0 , 2i.90 AfirlAEZAW FACILITIES DEPARTMENT ❑ AUBURN, WA. 98002 ❑ EVERETT, WA. 98201 ❑ KENT, WA. 98031 ❑ PORTLAND, OR. 97220 ❑ RENTON, WA. 98055 ® SEATTLE, WA. 98124 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED SY SUETITLE FLOOR PLAN ARCHITECTURAL MASTER BLDG. 14 -01.1 COL. 6 -•. • /D- LAST REVISION SYM90L SHEET N -. 8 - D( ) DWG NO. 114 - 0°1 Ds emu *•7S Rev. 7/03 t14•ool- 1029-62 AIF 0G tC, A7l114" -oot- u7.9•A15 7 114•ool -IOZ9 -416 A7I II •001-102.1-A.17 nvor2, - Fv Pt.t.JNIYJIN6n GLEAN OUT o29 •A18 O7A •Al e) FIRST FLOOR PLAN SCALE: 1/8 I' -0" PA.i TINGI ENGL.05URE •001- 1029••18 711 ';oO1- io2q•aMG 1=toa9 -1221 7.111 - oot•10o1 - ti 5 HI61H .c2UL.It7• E'VJ. PANEL Pt.lGIN61 SEE ' 114-001-102. 1 1029 -ally 7 II .001-WV-All GoNGP,ETE WALL, C.�NGPnETA MASONRY UwIT ;GMU) WAI STEEL. ST1J17 wcwv c-3fUD WALL. EX S I N 6n WP.LL. Ia+EMOV,4L. vA�, ON . aGOtJSMC " HIG11 — 1 UPS - ! ' • O" HI(,H A', vTL=7 Cc �' JJG1� oN H° I� NEW 1 2Gi01-112/I/z t1561-1 S' I-16H 51-{OPE1-I PAHEL-. I /IA r .w I2" HOP F�1 PAN GI.. 5 1/106.619 ( 3 Hew sNoP r -r►ri: posy. Lf HAW R VE - i-.H. SWIPE SwIHc-, 6AT• w /1- GY.KSET. 7 H LW a' 2" WIVE- s rbn 1=E1 IGE FAH El- . A - 3 I A A -5 A -6 A -8 A - 9 A -10 PERMIT CENTER 0 ,.,..,„'„ 1 2 ' • I ' I I ' ' ' 1 ' ' ` I ' I ' 3 4 5 6 7 8 FLEXIBLE RULER - JU2AW.. •...,,.— OC 6Z (3L LZ 9Z SZ •Z CZ ZZ lZ Oz 61 El Ll 91 GI VI Cl ZI ll IIIIIII II IF THIS MICROFILMED DOCUMENT IS LESS I CLEAR THAN THIS NOTICE, IT IS DUE TO Al THE QUALITY OF THE ORIGINAL. DOCUMENT 0 SYM 0l 0I MOO 41117! 66v. 7/S3 REVISION 0� —I 0V 2v' -0" (L Tti._ U4•ov1•lv2°I -A14 A P 1114•ov1 -lo29 - 114 APPROVED r'd-I- A�RFA5 MANUA(it - Nb, DATE SYM b 10.2 AI( 114.001- 1029 - /L14 gv0g41 Jobit tt iv, o 4 - 2o' -o" REVISION 14 abl " �ooi... 4L'S 5G R", U) o•1O 1z• P 'b O 7D 5 170 x x i ey t. 10.4 HAMA x E_ A 411`-0ot -ton 4.12 opNue - Ini O Oz ■Y I _ I 'I' I I1 I 'I' 1 0 1a 1N • /NCH 1 2 20 �iXEo NUUD oBT. 1 AFB 11 •oQ1.107, -AZ1 24' - 0" PouP -• AI ----- PL-LJ INGi N OUT SY 311 L. '1 APPROVED DATE Lo•23 b•28 ! - I XEJ WOor 13UL.L. 3 4 5 6 2 )' -o ' � —X A 11 - 101- IVZ9 -A27 FIRST FLOOR PLAN SCALE : 1/8"=1 H16,H SoL,I PAI.IEL META.. FENCE 4 WIPE WHrrs -� AIsL.E 5 X —X _x— K x — X X X I; 3 ' -o'' ® ®A ®Af‘a FACILITIES DEPARTMENT 1 ' ' I I 7 FLEX113LE RULER -302 AWaanN.N.– so' -a" 13UL.L. o£ 5z 6e L. ez se ,z ez zz Iz Oz 61 ER LI 91 s1 ,I El zI a oL ' IIIIII TP+AN S P0PITAT10N L. O.. Ab 11 •001 -1029 A IZ I'II 8 I/I 1 (_7 LlJ \J " ❑ AUBURN, WA. 98002 El EVERETT, WA. 98201 ❑ KENT, WA. 98031 ❑ PORTLAND, OR. 97220 ❑ RENTON, WA. 98055 ® SEATTLE, WA. 98124 24 WHITE AK V1 rt 0 20 -o" t u L.L. • P-1A.1 L 8' 0" 1-1I61H 5ot,ly F"ANIeL. METAL. FEN■GII\1Q•1 Zo'- 0 14' -v" I� i i; .I.„ 0 I I IF THIS MICROFILMED DOCUMENT IS LESS CLEAR THAN THIS NOTICE, IT IS DUE TO THE QUALITY OF THE ORIGINAL DOCUMENT O APPROVED SY 12.2 2 '4 1 /17\. , 11 001 ;1OZ tr GIa , U 55HATGI'IINGI INDI6A7E5 GovEIZ+S W /AGGEScj MANI-IUL.E TO JTILITISS (TYP) , DEPT. ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS AF'PNOVED c7' ciAtei e D' - X ----5C AGG e poop, A.T PL.UM0I•61 Gl_EA N oUT 17EAGTI VATEl7 GL.oc r7 $� LAGK.ED t 0 1 II L TITLE SUBTITLE BLDG. 14 -01.1 I I Ioot A.28A GONGR,E - r MA I I .M STEEL. cT�uv ^� -- woo rdiut7 WA L_t.. >+XISTIN" 6n WALL — — P+I:M ON/A.A.:. . CONSTRUCTION NOTES= COL.9.4- 13/ D -E 5 FLOOR PLAN N LI'WIpE a' V2 ol-IP 5NoP . (rft'IGAI -) 5EE I /IA50o 1� I V Y I0 rI X e H I6H F H R7S'f (TYPICAL-) '7 1/1A5 V0 HEW (c'WIPI� SLIPINC, 6ATI: W /1-061 f W Z' WII2- /Z 501.12 --NCB 3}-IEI HEW I{ sWIHE 6 M W /1 s - TORPU I.66K.sE f. NEW 12j wit7E. I/Z SouD FrcNCrL. f lt ARCHITECTURAL MASTER • i T.• ' - LEGE GUNGP+ETE .PAP•TT 0 A.GUUsTrGA.I.- (.5' -0" . . ? . . ) " 1 - 1 1 6/HI AP= N ?T'6D KEY PLAN SCALE: 1 "= 20' D.C. O C l S r''..; LAST REVISION SHEET JOS NO. RECEIVED CITY OF TUKWILA PERMIT CENTER SYMIOI OWO NO. 114 - 1037 DATE fi SW A RENSION 900941 VACA FE LIGHTNING S IRIK,- 20' =0° — - --- 4' 0" (' -EAR 311 ('1 I DY APPRON 0 RATI 1'..0" MIN. CLEAR i TUBE. BE NDING MANUFACTURING AREA Io • ?3 'qo M ANUTAC NUKING ARIA A SYM 20'- 0 " - - - -- 20' -0" I =- REN':ION MANUFACTURING AREA li r APPROVED FLOOR PLAN Ii T HIN VW' = 1'- -0" DALE 18 20' -0" 20' -0" ISPEZEZAKW FACILITIES DEPARTMENT I . 1 I I I I } ; I , I , I , I , I , I . • I 1 I , I , I . I , I , I . I ' ' ' I I I . ' ' I I I I ' ' 1 ' ' i I . I I 0 ,., „.INCH 1 I 2 3 4 5 6 FLEXIBLE RULER - 302 AW.." "._ ; 06 6Z BC LZ 9Z GZ hZ CZ ZZ lZ 0? 61 UI Ll 91 GI VI Cl Zt U OL i ' IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII11 l._] AUBURN, WA. 98002 L7 EVERETT, WA. 98201 [] KENT, WA. 98031 PORTLAND, OR. 97220 L I RENTON, WA. 98055 ggriEAT1LE:, WA. 98124 20' -0" .- TRENCH COVERS(TYP) 20' -0” IF THIS MICROFILMED DOCUMENT IS LESS CLEAR THAN THIS NOTICE, IT IS DUE TO THE QUALITY OF THE ORIGINAL DOCUMENT E, 0 10 13 1Al2 1A16 1A10 1A13 1A17 KEY PLAN 1/8 = 1 ,_ 0 1, Ir ,: ' •'.tAid !I, ;NAP ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED Br DEPT. DATE DRAWN BY T. HANSON CHECKED CNrCNED DAZE 10 19 90 Io.13. 90 ID • 1. SuenYj£ TI BLDG. 14 - -01 COL. 16.2- 19 /D --E: GENERAL NOTES: 1. VERIFY ALL DIMENSIONS PRIOR TO CONSIRUCTION. 2. PAINT ALL SHOP FENCING AND SUPPORT POSTS PRESERVATIVE PAINT'S IIGIITSTRING COLOR (TYPICAL) CONSTRUCTION NOTES: EXISTING SHOP FENCING TO REMAIN (NO WORK) NEW 1 -1/4" 8 FT HIGH FENCE POSTS. SEE 1/IA500 G 8' -0" WIDE SLIDING SHOP FENCE WITH HASPS. 12" WIDE SHOP FENCE PANEL. 3'x7' SHOP SWING GATE WITH MORTISE. STORAGE LOCKSET. 3' -0" WIDE SHOP FENCE PANEL. RELOCATED 6' -7' HIGH O'BRIEN HARDWALL. USE MIN. 2 EA. HILTI KW11( BOLT 1/4 "x5" PER BASE INTO CONIC. 1A14 IA18 NEW 8'- -0" HIGH BY 4' - -0" WIDE SHOP FENCE PANE' S ( PANELS TYPICAL). TO BE 1/2 SOLID, 1/2 MESH CONSTRUCTION 1A11 IA15 PARTIAL 14 - -01 FLOOR PLAN ARCHITECTURAL MASTER D C. SHEET JOB NO C ` I 00 \1 k t�0 -Z 9 1`j00 {E� RECEIVED CITY OF TI IKWILA PERMIT CENTER t AS1 REVSION I SYMBOL 1A19 900941 DWG NO 14 -01 -1A19 DATE a i Sri 4 REMSION (Au.) qoo qy I VAGATE 6. 6fRl1 K E BY 31-r APPROVED DATE o. 23.9a Sri RENSION BY APPROVED DATE ( FACILITIES DEPARTMENT - I I I I I T I'I'I � . 1 . T . • .I:I. '1,1 I•T I - .1 l l'I I i•l'i I I . . ,. I ,. . 0 ° "• <" 1 2 3 4 5 6 7 "I�Ify7 FLEXIBLE RULER - 302 AWo."... "v- ?! 1 oc 6Z Be LZ 9Z SE VZ CZ ZE lZ 0? 61 91 Ll 91 DI Vl Cl El ll OL IIIII IIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIII • SLOT DETAIL SEC. C -C ❑ AUBURN, WA. 98002 [:VERETT, WA. 98201 C] KENT, WA. 98031 ❑ PORTLAND, OR. 97220 U RENTON, WA. 98055 SEATTLE, WA. 98124 16 GA. Si 11. MIL. - WELDED TO INSIDE FRAME ® 6" O.C. "xl "xl /8" "L" SEC. 3 -F3 APPROVED BY POST 1 "xl "x1/8" "I" 1 "x.l "xl /8" "T" 16 GA. sH r. MTL. WELDED TO INSIDE FRAME @ 6" O.C. ACCEPTABILITY FINIS DESIGN AND /OR SPECIFICATION IS APPROVED DEPT. IF THIS MICROFILMED DOCUMENT IS LESS CLEAR THAN THIS NOTICE, IT IS DUE TO THE QUALITY OF THE ORIGINAL DOCUMENT CONDUI T BU I TON FILE ERS Ar E XPOSED HOLES _ 1 - -1/4" SQUARE 14 GA. STEEL TUBE SLEEVE -- PLUG WELD (2) SIDES 6" x 6" x 1/4" MILD srEI L BASE PLATE. 11/16" HOLES TYPICAI. 4 LOCATIONS .— SECURE TO WOOD FLOOR WITH 5/8" LAG BOLTS & TO CONCRETE FLOORS 1MTFI 5/8" BOLTS & EXPANSIONS SHIEI I)S. SEC. A -A 1-1/2" SQUARE 14 CA. COLD ROLLED STEEL. TUBE ' 9/32" THRU HOLES TYPICAL Al 4 LOCATIONS NOTE: 100% WELD TUBE & SLEEVE TO BASE PLATE DRAWN BY T. HANSON EVE ED 1 "x1 "xl /8" "E" NO. 1 0 x 1 - 1 /2" EXPANDED MTL - MESH. WELD ro INSIDE FRAME W 6" O.C. DATE SODRTLE 10 11-90 I¢ '0 Df� o I IANSD'I TIRE EHLDC. 9 -101 8-/ -90 — BEVEL CORNERS A C-e 17', 24 ", 36" & 48" PANELS FL[ VATIO\ (,I NE RAI. N01 T S: I I. S FO OF SHOP PRIME D. TOP CCAI 10 BE AI I': YO 1 rIAMEE, 1R[ ':J RGA FIVE PAINT COLOR "I ICH F SITING ". 16 CA SHEE I STEEL MAY BE USED IN LIEU OF LXFANDFI) MTI MESH UPON SPECIAL RI QUESI. REDRAWN FROM NOBERAGE STELE. CO. STANDARD DL TAIL. FOR FENCING. TYP. SHOP FENCE DETAILS c0 ASNETRZAW No SCALE ( TYPICAL) 1 / < TYPICAI 8 - R-1 -I- -- NO 10 x 1-1/2" EXPANDED ME 1AL MESH WEI OLD 6" O.0 TO INSIDE FRAME - 1" x 1" x 1/8" "T" SEE IYPICAL `;I OT DETAIL (EA SOF) - 16 CA. SIZE L I METAL x I" x 1/8" "L" SK311900807 Al TYP. SHOP FENCE NO SCALE 1 A.500 A -1 ARCHITECTURAL MASTER D C RECEIVED CITY OF TUKWILA F PERMIT CENTER 900910 -2 A(ALL) 10/90 IAS1 REVSION SHEET 1A500 SYlAUOI OO NO. 900910-- DAT NO. �) - 101 - IA 500 DATE or 1