HomeMy WebLinkAboutPermit M07-046 - INTERNAPINTERNAP 3355 S 120 PL M07 -046 Parcel No.: 1023049069 Address: Suite No: 3355 S 120 PL TUKW Citf Tukwila Tenant: Name: INTERNAP Address: 3355 S 120 PL , TUKWILA WA Contractor: Name: HERMANSON COMPANY LLP Address: 1221 2ND AV N , KENT, WA Contractor License No: HERMACLOO5BJ Value of Mechanical: 000,000.00 Type of Fire Protection: SPRINKLER/AFA Furnace: <100K BTU > 100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT Owner: Name: SABEY CORPORATION Address: 12201 TUKWILA INTL BLVD 4THFL , SEATTLE WA Contact Person: Name: JEFFREY PENCEK Address: 228 E 45 ST, 7 FLOOR , NEW YORK NY DESCRIPTION OF WORK: ROOFTOP MOUNTED AIR HANDLING UNITS /EXHAUST FANS FOR COOLING .AND VENTILATING OF NEW DATA CENTER. INTERIOR MOUNTED AHU TO COOL/VENTILATE THE UPS AND BATTERY ROOMS LOCATED ON THE FIRST FLOOR. EOUIPMENT TYPE AND OUANTITY 0 0 0 0 0 0 1 6 0 5 0 0 0 0 * *continued on next page ** M07 -046 Permit Number: MO7-046 Issue Date: 05/15/2007 Permit Expires On: 11/11/2007 Phone: Phone: 203 536 -2152 Phone: 206 - 575 -9700 Expiration Date: 08/25/2008 Fees Collected: $8,336.75 International Mechanical Code Edition: 2003 Boiler Compressor: 0-3 HP /100,000 BTU 0 3 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30-50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 10 Diffuser 10 Thermostat 6 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 2 Other Mechanical Equipment 0 Printed: 05-15 -2007 Permit Center Authorized Signature I hereby certify that I have read an governing this work will be compli The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulatinc constructio the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: Print Name: doc: IMC -10/06 1l City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: MO7 -046 Issue Date: 05/15/2007 Permit Expires On: 11/11/2007 Date:./ ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. Date: 5//570 7 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspender or abandoned for a period of 180 days from the last inspection. M07 -046 Printed: 05-15 -2007 Parcel No.: 1023049069 Address: 3355 5 120 PL TUICW Suite No: Tenant: INTERNAP 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M07 - 046 Status: ISSUED Applied Date: 03/06/2007 Issue Date: 05/15/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation inst ructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431- 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be doc: Cond -10/06 M07 -046 Printed: 05-15 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IIVMC 606.1, 606.2.1) 16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 18: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IF'C 104.2) 20: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 -3670) is required for this project. 21: The Tukwila Fire Department has changed keybox manufacturers, from Supra to Knox. Install a fire department Knox keybox. Contact the Tukwila Fire Prevention Office at 206 - 575 -4407 for ordering information. 22: Installation of aboveground and underground fuel tanks requires a separate fire department permit (206 - 575 -4407) for each tank. 23: Generator installations shall comply with International Mechanical Code and the National Electrical Code. 24: Fuel tank installations shall comply with Chapter 34 of the International Fire Code. 25: The generator room shall comply with the sprinkler protection criteria required by International Fire Code section 2704.5, ordinary hazard group 2 with a minimum design area of 3,000 square feet and an increase of 30 percent design area for pre - action systems. 26: The total number of fire extinguishers required for an extra hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (4A 40 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 27: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 28: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 29: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 30: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the doc: Cond -10/06 M07 -046 Printed: 05-15 -2007 City of Tukwila inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4 -4) 31: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 32: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us * *continued on next page ** M07 -046 Printed: 05-15 -2007 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: OM) VeA4 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us y rS Date: 1/5/0 7 doc: Cond -10/06 M07 -046 Printed: 05-15 -2007 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hap://www.ci.tukwilawaus King Co Assessor's Tax No.: ( - 0(,11 Site Address: 3355 South 120th St.QQQ Suite Number: Floor: Tenant Name: Internap New Tenant: ❑ Yes ]..No Property Owners Name: Sabey Corporation Mailing Address: 12201 Tukwild International Blvd. CONTACT PERSON who do we contact when your permit is ready to be issued Name: Jeffrey Pencek Mailing Address: 228 E. 45th Street, 7th Flr. E Address: jpencek@ha-ny.com GENERAL CONTRACTOR INFORMATION (Contractor Information: for Meehanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: 'ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: Cortland Morgan, Architect, AIA 711 N. Fielder Road Jeff Smith Contact Person: E - Mail Address: Jeff @cmaia.net ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: ThP Pinrriy Cnnsul tants Mailing Address: 14850 Montfort Drive, Suite 250 Contact Person: Lawrence Purdy E - Mail Address: j 1purdy@j 1penterprises. ccm Q tApplications\Forms- Applications On Line \3-2006 - Permit Application.doc Revised: 9 -2006 bh Building prrrit Mechanical Pe Plumbing /Gas Perini Public Works Pei iit Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Seattle City WA State 203 - 536 -2152 NY 212- 68 0201 Day Telephone: New York City Fax Number: City Day Telephone: Fax Number: Expiration Date: State Arlington TX Dallas Cit Day Telephone: Fax Number: 972 - 386 -6837 Zip 10017 Zip Zip 76012 City State Zip Day Telephone: 817 636 - 5696 Fax Number: 817- 636 -5699 TX 7544 State Zip 972 - 386 -6836 Page 1 of 6 BUILDING PERMIT INFORMATION — 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 800, 000.00 ` Existing Building Valuation: $ Scope of Work (please provide detailed information): Provide a co — location data center fitting up existing shell space. Fit -up includes back -up emergency power and cooling. Will there be new rack storage? ❑ Yes [.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: N/A Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: a Sprinklers ® Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ® No If `yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM N/A ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q \ApplicationsTorms- Applications On Line \3 -2006 - Permit Application. doc Revised: 9 - 2006 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per, IBC 1 Floor 188,222 SF 7940 SF 1 — FR FT 2 Floor 3 Floor 183, 292 SF 12, 000 SF 1 -FR FI Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORMATION — 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 800, 000.00 ` Existing Building Valuation: $ Scope of Work (please provide detailed information): Provide a co — location data center fitting up existing shell space. Fit -up includes back -up emergency power and cooling. Will there be new rack storage? ❑ Yes [.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: N/A Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: a Sprinklers ® Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ® No If `yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM N/A ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q \ApplicationsTorms- Applications On Line \3 -2006 - Permit Application. doc Revised: 9 - 2006 bh Page 2 of 6 Scope of Work (please provide detailed information): 14 /A Water District ❑ ...Tukwila ❑ ...Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water It Q: \Applications\Ponns- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh Call before you Dig: 1- 800 - 424 -5555 lease refer to Public Works Bulletin #1 for fees and estimate sheet. ❑ ... ValVue ❑ .. Renton ❑ ... Sewer Availability Provided Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line ❑ .. Highline ❑ .- Geotechnical Report ❑ .. Maintenance Agreement(s) ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Renton ❑ .. Seattle ❑ -. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size .. WO # ❑ ...Water Only Meter Size WO # ❑ ...Deduct Water Meter Size ❑ ...Sewer Main Extension Public Private ❑ ...Water Main Extension Public Private FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund /Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip Page 3 of 6 Ilriif`Ttyper :: Qy •Utut Tyi Qty ''UNit`Type: " Qty` Borer /Coiiip Qty Furnace <100K BTU Air Handling Unit >10,000 CFM 6 Fire Damper 10 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 1(j 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct 5 Thermostat 6 15 -30 HP /1,000,000 BTU Suspended/Wall /Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 2 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM 1 Incinerator — Comm/Ind MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ 1 , 000,000.00 Scope of Work (please provide detailed information): Rooftop mounted air handling units / exhaust fans for cooling / ventilating of new data center. Interior mounted AHU to cool / ventilate the UPS and Battery Roans located on the First Floor. Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... [ Replacement .... ❑ State Zip Fuel Type: Electric Gas ....Li Other: Indicate type of mechanical work being installed and the quantity below: Q Applications On Line13-2006 - Permit Application.doc Revised: 9 -2006 bh Page 4 of6 +'I 0101 ;T'yp`e .,. ,.Qty �Fiirture,'I ` c yp � ':Qty ' -- Ftxture - >. ;Qt Fixture T e y P. Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain , Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and /or vent Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets /outlets for specific gas PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: City Contact Person: Day Telephone: E-Mail Address: Fax Number: Expiration Date: Contractor Registration Number: Valuation of Plumbing work (contractor's bid price): $ N/A Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Int'1 Building Code): Occupancy (per Int'I Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and /or gas piping outlets being installed and the quantity below: Q. AApplications \ores- Applications On Line13 -2006 - Permit Application. doc Revised. 9 -2006 bh State Zip Page 5 of 6 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested -. in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY : Y THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O Signaturk: Print N4i / Mailing Address: AUT 1 RIZED AGENT: 2,21 E 4g f Date Application Accepted: 0 4 *1 Date Application Expires: o°1l Staff Initials: Q. \Applications\Forms - Applications On Line \3 -2006 - Permit Application. dot Revised. 9 -2006 6I Date: 3N Day Telephone: 14 Z - ‘q., —13 1. �`�a` Iy� I loo 17 City State Zip Page 6 of 6 Parcel No.: 1023049069 Address: 3355 S 120 PL TUKW Suite No: Applicant: INTERNAP Receipt No.: R07 -01060 Payee: RERMANSON CO. LLP TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http:/lwww.citukwila.wa.us RECEIPT Initials: JEM Payment Date: 06/06/2007 03:18 PM User ID: 1165 Balance: $0.00 Amount Payment Check 1711 58.00 Account Code Current Pmts 000/322.100 58.00 Total: $58.00 Permit Number: M07 -046 Status: ISSUED Applied Date: 03/06/2007 Issue Date: 05/15/2007 Payment .Amount: $58.00 9017 06/06 9716 TOTAL 58.00 doc: Receipt -06 Printed: 06-06 -2007 Receipt No.: R07 -00849 Initials: JEM User ID: 1165 Payee: HERMANSON COMPANY LLP ACCOUNT ITEM LIST: Description MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 1023049069 Permit Number: M07 -046 Address: 3355 S 120 PL TUKW Status: APPROVED Suite No: Applied Date: 03/06/2007 Applicant: INTERNAP Issue Date: TRANSACTION LIST: Type Method Description Amount Payment Check 51547 6,675.40 Account Code Current Pmts 000/322.100 6,675.40 Total: $6,675.40 Payment Amount: $6,675.40 Payment Date: 05/15/2007 03:38 PM Balance: $0.00 8226 05/15 9716 TOTAL 6675.40 tint.: RAmint -OR PrintAd 05-15 -21107 Parcel No.: 1023049069 Address: Suite No: Applicant: INTERNAP Receipt No.: R07 -00322 Initials: JEM User ID: 1684 Payee: TRANSACTION LIST: Type Method Description Payment Check 1016 ACCOUNT ITEM LIST: Description 3355 5 120 PL TUKW City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RUBICON INTEGRATION, LLC Account Code PLAN CHECK - NONRES 000/345.830 RECEIPT Total: $1,661.35 Permit Number: Status: Applied Date: Issue Date: Payment Amount: Payment Date: Balance: Amount 1,661.35 Current Pmts 1,661.35 $1,661.35 M07 -046 PENDING 03/06/2007 03/06/2007 10:33 AM $6,675.40 doc: Receiot -06 Printed: 03 -06 -2007 Project: _ - Z- IVAV /V /Id Type of Inspection: f 7 /V / Address: 3.3 S /2d nL Date Called: Special Instructions: Date Wanted: -� a .. Requester: /)c `' �" `y r'1 i r 1 i ki Phone No -3L-- 7 1 c i(3'/ INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 gl Approved per applicable codes. INSPECTION RECORD Retain a copy with permit (206)431 -3 Corrections required prior to approval. COMMENTS: P4 - ft - i -7 ( 7 12/-r7/2 / � /i7 — /41/1/ Date " 3- d/ .00 REINSPECT) N FEE INQUIRED. Prior to inspection, fee must be aid at 6300 Southc nter BKrd.. Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: COMMENTS: / /74v,c. - / if /ek,rvi (---.,)/,v l -7,. -- 7, l' ,X7 j• r /7-- ,7i :7 . //J 2 1 7 ./f . r.C - 4Z17 ; ((.0 s`1,v/' /i.ry (le -/7 i 5-7 2 /� ✓ -/� l // ,,, ,,- SC 5 7;-,-, / t . f 4°(z'7 J i4 _/ -14 / 77/, >;- r/ /w.S,--% dt ?lam c-".: "' :II i-ri ( //; 1, ec.. //-7 r ° /� , J,�iF� f�y� - 1,e l y., /1 /0 T C •' ( k /e ✓,./ 4 L✓ /j rite k_ ii," ' 3_— ( / ,- ' /A _5 1 ) ,f1/ r7 7) (((C Project: �A) k ✓/t/ L7; Type of Inspection: /'LJ l Ad 33 �� o i'L S D Called: Special Instructions: Date Wanted: a.m,. Requester: Phone No: X 0 6- 39/ -5 /°y ,^,^r N -•' ..ray:.. p ctor: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 CT FEE REQ PER • ► ,* 1 El Approved per applicable codes. Corrections required prior to approval. Date: (20 )43 1 -3670 X 58.00 REINSPE ED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: COMMENTS: Type of Inspection: / Q_) D' . � 1 /U S. Special Instructions: Date Wanted: '7- i 5- p 7 trr : a.m. (2t) ✓n �� / S l-k., -f __ . V - ??/ Project: /' V Type of Inspection: / Address: 3 5 5" S 176 e l Date Called: Special Instructions: Date Wanted: '7- i 5- p 7 trr : a.m. Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISIO 6300 Southcenter Blvd., #100, Tukwila, WA 98188 'Inspect r: jtivv'7 11 pproved per applicable codes. Corrections required prior to approval. Date All 1 — C7 $58. t1SPECTION FEE RE UIRED. P /rto inspection. fee must be paid �t4300 Southcenter Blvd.. 100. Call the schedule reinspection. (Receipt No.: 'Date: COMMENTS: - \ ° i ) 4 / C Lch-e_//t,-/J-fr-7 >/,,-- I/7 essg• /C ,177 >4/ • K? 1,,,, A7 c./ e 0^ (.3 ,, / I Ale,--e77.1 G1 .70t, a,-.2 - A , S e,r, 5 / el2; .c / 644 I4a I 1-7,,,-.7,-/,/ ./1 ,21/./ Cecile , 2_) lq-me ,ped.7 yoor 7?-7 o ii e.& n", 1,9c7 4 igp I fil-A, 5) liod 14od „C",41.7e (Ind ivese/ 6,0-e/A-y vie.," /104 1) 1 S *4 6/ ',A ;AV/ e.4" i 44-„// ,, 10 4460 Project: / Type of Inspection: C-- f AA Address: 3355 ---s" / ( Date Called: Special Instructions: , Date Wanted: 7- /2,-- 07 Ca.m3", Requester: Phone No: „206 .? / - c INSPECTION RECORD Retain a copy with permit INSPE ON NO. CITY OF TUKWILA BUILDING DIVISION 63 00 Southcenter Blvd., #100, Tukwila, WA 98188 /) (206)431-3670 Approved per applicable codes. Corrections required prior to approval. Inspector: Date7._ r eceipt No.: Date: 'Vg 0 $58.110 REINSPECTI0IFE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Project: , _ Type o Inspection: ^ /`' Add es • �o l� ate Called: Special Instructions: Date Wanted: 73 - i 9 7 Cr. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 FAM., PER# •/ (206)431 -367 proved per applicable codes. Corrections required prior to approval. COMMENTS: $58.00 REINP CTION FEE E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: 'Date: Project: Type of Inspection: .. ' Address: ?>3 S 170 PL Date Called: Special Instructions: Date Wanted: (/--- / 7 (O - ( a.m. rn- 7 Requester: Phone No: / INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 007-0-(6 (206)431 -36 Approved per applicable codes. El Corrections required prior to approval. OMMENTS: Inspecgor: 'Date: El $58.00 I SPECTION E REQUIRED. Prior to inspection. fee must be paid at 6 00 Southcent (Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: INSPECTION RECORD with permit Imo U y' Retain a copy P PERMIT • • INSPECT! N NO. CITY OF TUKWILA BUILDING DIVISION 'a. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (2 6)431 -3670 Project: _a ,J4e r N 2 Address: f3 355 S Ito PC., Special Instructions: Type of Inspection: Date Called: Date Wanted: - 13 Requester: Phone No: El Approved per applicable codes. Il Corrections required prior to approval. COMMENTS: pA, /7) C v � . ^ �,► 1. �ti' I Date6 -4 El $58.00 REINSPECTI6N FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Date: (Receipt No.: Pro ec ' icil4iimp Type of Inspection: Ad dress: ate Called: Special Instructions: Date Wanted: ld.m S 3/ - - 07 . Requester: Phone No 7.€6 r3 / —/ INSPECTION RECORD Retain a copy with permit INSPE • N NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. PER , NO. 06)431 -3 Corrections required prior to approval. COMMENTS: e A (2tfi,f.jie /A !Date: 2, 07 $58.00 REINSPECTION Fa REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: • eyjl ProjtCL--- Type of Inspection: Address Date Called: Special Instructions: Date Wanted: 5-- 3Ao Requester: Phone No: 3r/- g/gt-1 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 COMMENTS: 'Inspector: INSPECTION RECORD Retain a copy with permit A-- No7 PER El Approved per applicable codes. El Corrections required prior to approval. (W 7:7 c -7i = 1/ Le Ae 9/2 (/7, 5 / , Date: 3/ ( 06)431- 67 El $58.00 REINSPECTIO FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Proms Y A/77/7 ( f) 7 Andress: 3.35:5---5- /2d / Date Called: -- Special Instructions: .L4! c 4,./ O` l..-e / - S0G.4. /.t/ , / 2 2 -c p arr -- ) i'-'8 PnQ r ki; s p et e 0074---c-74.„- Pho No: � 6 -3�/ - e9/ % /t-1 r re✓ ,s-, 7 Zfrt'p / ;/1 y / F f r-e 0 ;:e 0. .4; X. S'Aoe4k5. ''., 7 fuoif. (2 5'1.. Proms Y A/77/7 Type of Inspection: t ' i r , Andress: 3.35:5---5- /2d / Date Called: -- Special Instructions: Date Wanted: Ca:nt 2 2 -c p arr -- ) Requester: Pho No: � 6 -3�/ - e9/ % INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 El Approved per applicable codes. Inspect ❑ $58.00 REINS FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit /776 7 - cV6 Corrections required prior to approval.6 (Date: � ?—t1:77 COMMENTS: ,-- t 1 ; . : c: 1- i'=1, le-";' Hood & Duct: Monitor: P Type of Inspection: I i.: , , ,...„. ' e 4 '1,i ‘; ' ■ z ( ... !,:-..... - ej . ,.._...-. 1 - A .„„..., .. r _k_ , --- t..- .-- •1%-i k 4 -7 1, \ , - :: ...._. -- ,r,-3 ,,,, t 1.--) I r wq, 1-- , -- ,,,,,. Phone No.: .. .. 4 , , ,,t tr ,- i p if:11,i u i ‘2114.1.1o.0 \=)ii..(> b t9,- . - i :...5 .., Project: :is ;-,._ , , ,-- Fire Alarm: H Hood & Duct: Monitor: P Type of Inspection: I i.: , Address: '.--- - Suite #: ej f 2 -"--" A ' Contoct Person: , Special Instructions: Phone No.: Needs Shift Inspection: S Sprinklers: Fire Alarm: H Hood & Duct: Monitor: P Pre-Fire: Permits: O Occupancy Type: INSPECTION NUMBER Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT Word/Inspection Record Form.Doc 1/13/06 PERMIT NUMBERS Ia. W . 98188 206-575-4407 Corrections required prior to approval. Inspector: Date: , • 7 / -7 Hrs.: 3 $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from e City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 C9 4M NTS: Sprinklers: Fire Alarm: Type of Inspection: in-i . AiA..4 f /G.,. /Cs,94,5,1, — 7 - in-ix . Address: ?3 SS' S Suite #: i 2 v 5� Contact Person: /3 : // G 4.)(- Ad,' _S Special Instructions: Phone No.: ,2' - G / 7 - l- /S'l Chc,,Lroe- a.-- 6 ) 6:U 1 2 60 Px Project: Sprinklers: Fire Alarm: Type of Inspection: in-i . AiA..4 f /G.,. /Cs,94,5,1, — 7 - in-ix . Address: ?3 SS' S Suite #: i 2 v 5� Contact Person: /3 : // G 4.)(- Ad,' _S Special Instructions: Phone No.: ,2' - G / 7 - l- /S'l Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: _ Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT Word /Inspection Record Form.Doc 1/13/06 ii)07 --o<<(, PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 I I Corrections required prior to approval. Inspector: stv Date: 6/z ?/a 7 Hrs.: l $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 Motor Data AC 5 -01 / Supply Fan Motor Manufacturer G.E. Motor HP 2 HP Motor RPM 1725 RPM Motor Frame 145T Motor Rated Volts 460 Volts Motor Phase 3 Motor Hertz 60 Hz Motor FL Amps 3.1 Amps Motor Service Factor 1.15 Sheave Data AC 5-01 / Suooly Fan Drive Type Belt Belt Size AX32 Number of Belts 1 Motor Sheave 1VL44 Motor Sheave Bore 7/8 in. Fan Sheave AK64 Fan Sheave Bore 1 in. Sheave Center Line 91/2 in. Test Pressures AC 5 -01 / Supply Fan Extemal SP Design .5 in. Inlet Ext SP .03 in. Discharge Ext SP .80 in. Actual Total Ext SP .83 in. Unit Data Unit Manufacturer Trane Unit Model Number TSC090A4RGA Unit Serial Number 720101842L AC 5 -01 / SF Filter Bank Filter Type Fiberglass Filter Quantity 4 Filter Size 16x25x2 AC 5 -01 / Supply Fan Fan Type / Class FC/t Test Data Total CFM Design 2400 CFM Total CFM Actual 1845 CFM Outside Air CFM Actual 200 CFM Return Air CFM Actual 1645 CFM AC 5 -01 / Supply Fan Fan RPM Actual 942 RPM Electrical Test Data AC 5 -01 / Supply Fan Motor Volts 1 482 Volts Motor Volts 2 482 Volts Motor Volts 3 482 Volts Motor Amps 1 3.10 Amps Motor Amps 2 3.00 Amps Motor Amps 3 3.10 Amps AIRTEST Co., Inc. DRAFT Roof Top Unit Report PROJECT: •Internap LOCATION: Tukwila, WA PROJECT #: 07 4045 - SYSTEM /UNIT: AC 5-01 AREA: Intemap Office Notes: Ahtest Co Inc DATE: August 02, 2007 CONTACT: Mike Kehoe 4 Tested By: Mike Kehoe Date: August 02, 2007 Unit Data VAV Type Shut -Off Box Inlet Size 12 RD Test Data Design Primary Max CFM 1000 CFM Actual Max Primary CFM 1020 CFM Design Primary Min. CFM 325 CFM Actual Primary Min. CFM 320 CFM Unit Data VAV Type Shut -Off Box Inlet Size 6 RD Test Data Design Primary Max CFM 240 CFM Actual Max Primary CFM 235 CFM Design Primary Min. CFM 80 CFM Actual Primary Min. CFM 78 CFM AIRTEST Co., Inc. 1 Eig DRAFT VAV Box Report PROJECT: *Internap LOCATION: Tukwila, WA PROJECT #: 07- 4045 -1 SYSTEM /UNIT: AC 5 -01 / VAV-01 AREA: Office Notes: SYSTEM /UNIT: AC 5 -01 / VAV-02 AREA: Office Notes: Airiest Co inc DATE: August 02, 2007 CONTACT: Mike Kehoe Tested By: Mike Kehoe Date: August 02, 2007 Tested By: Mike Kehoe Date: August 02, 2007 2/4 Unit Data VAV Type Shut -Off Box Inlet Size 8 RD Test Data Design Primary Max CFM 600 CFM Actual Max Primary CFM 590 CFM Design Primary Min. CFM 145 CFM Actual Primary Min. CFM 135 CFM AIRTEST Co., Inc. DRAFT VAV Box Report PROJECT: *Internap LOCATION: Tukwila, WA PROJECT #: 07- 4045 -1 SYSTEM /UNIT: AC 5-01 / VAV-03 AREA: Entry Notes: Airiest Co Inc DATE: August 02, 2007 CONTACT: Mike Kehoe 3/4 Tested By: Mike Kehoe Date: August 02, 2007 REF 11 Served By VAV -02 Area Served Outlet Type Size AK Final % Dev. Design CFM Final CFM Pref➢m CFM 1 CFM 2 CFM Test Date 2 Supply -01 Security CD 8 RD - 100% 225 225 115 0 0 2- Aug -07 3 Supply -02 Office CD 8 RD - 109% 225 245 135 0 0 2- Aug -07 4 Supply -03 Office CD 8 RD - 104% 225 235 230 0 0 2 Aug - 07 5 Supply -04 Office CD 8 RD - 96% 225 215 270 0 0 2 -Aug -07 6 Supply -05 Office CD 8 RD - 100% 100 100 40 0 0 2- Aug -07 ,Sub- Totals - VAV -02 102% 1,000 1,020 790 0 0 REF # Served By VAV-03 Area Served Outlet Type Size AK Final % Dev. Design CFM Final CFM Prelim CFM 1 CFM 2 CFM Test Date 7 Supply -01 Entry CD 8 RD - 100% 175 175 145 0 0 2- Aug -07 8 Supply -02 Entry CD 8 RD - 91% 175 160 125 0 0 2- Aug -07 9 Supply -03 Storage CD 8 RD - 102% 250 255 225 0 0 2- Aug -07 Sub - Totals - VAV -03 98% 600 590 495 0 0 REF # Served By VAV -01 Area Served Outlet Type Size AK Final % Dev. Design CFM Final CFM Prelim CFM 2 CFM Test Date 1 Supply -01 Office LD -1 8 RD - 98% 240 235 235 0 0 2 - Aug - 07 AIRTEST Co., Inc. DARFT Air Outlet Summary Report PROJECT: *Intemap LOCATION: Tukwila, WA PROJECT #: 07- 4045 -1 All Air Outlets Served By: AC 5-01 DATE: August 02, 2007 TECHNICIAN: Mike Kehoe Airiest Co Inc DRAFT TAB REPORT 4/4 April 25, 2007 Jeffrey Pencek 228 East 45 Street, 7th Floor New York, NY 10017 RE: CORRECTION LETTER #1 Mechanical Permit Application Number M07 -046 Internap — 3355 South 120 Place Dear Mr. Pencek: This letter is to inform you of corrections that must be addressed before your mechanical permit can be ' approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Fire Department. At this time the Building Department has no comments. Fire Department: Al Metzler, at 206 575 -4407, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 433 -7165. Brenda Holt Permit Coordinator encl xc: File No. M07 -046 Department of Community Development Steve Lancaster, Director City of Tukwila P:Uennifer \Correction Letters\2007\M07 -046 Correction Ltr #1.DOC jem Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 FIRE DEPARTMENT REVIEW COMMENTS Project Name: Internap 3355 S 120 Pi Permit File No.: M07 -046 Date: April 24, 2007 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575 -4407 Provide type and quantities of refrigerant to be used in cooling equipment. ACTIVITY NUMBER: M07 -046 DATE: 05 -31 -07 PROJECT NAME: INTERNAP SITE ADDRESS: 3355 S 120 PL Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # 1 After Permit Issued DEPARTMENTS: Bui,4img Divls on Public Works Complete Comments: Documents/routing slip.doc 2 -28-02 F'I NMIT WORD COPY PLAN REVIEW /ROUTING SLIP APPROVALS CSR CORRECTIONS: Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete TUES/THURS ROU NG: Please Route Structural Review Required REVIEWER'S INITIALS: ❑ DATE: DATE: Planning Division Permit Coordinator n DUE DATE: 06-05-07 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DUE DATE: 07-03-07 Approved L Approved with Conditions ❑ Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: M07 - 046 DATE: 05 - -07 PROJECT NAME: INTERNAP SITE ADDRESS: 3355 S 120 PL Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS: Building Division Public Works Complete Comments: Documents/routing slip.doc 2 -28-02 PLAN REVIEW /ROUTING SLIP PERMIT COORD COPY oct Fire revention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUESITHURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: ❑ Planning Division ❑ Permit Coordinator DUE DATE: 05-08-07 Not Applicable ❑ No further Review Required DATE: DATE: C C DUE DATE: 06-05-07 Not Approved (attach comments) C Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: M07 -046 DATE: 03 -06 -07 PROJECT NAME: INTERNAP SITE ADDRESS: 3355 S 120 PL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS : 41 Bui . g kion Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: TUES/THURS ROUT NG: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents routing slip.doc 2 -28 -02 'PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP 511 derma Fire Prevention Structural Incomplete ❑ ❑ DUE DATE: 03-08-07 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: DUE DATE: 04 -05-07 Approved ❑ Approved with Conditions n Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Planning Division Permit Coordinator n n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: 14611 Bldg ❑ Fire u Ping ❑ PW ❑ Staff Initials: 141444-7 REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 rF J urn- v`- Summary of Revision: A (k &kw, �, vt\ A(.4 5 I Received by: 1- / REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: - Received by: PROJECT NAME: I }._I' T:11/ SITE ADDRESS: i 4 0-0 In. REVISION LOG PERMIT NO: NWT ORIGINAL ISSUE DATE: is/ Di_ (please print) (please print) (please print) (please print) (please print) City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: http : //www,cl.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, eta Date: 501107 Plan ChecWPermit Number: 11107 - 0` 0 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # j Revision # . 1 after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: .1 0er ncup Sal* Do kid C j kti Project Address: ` � Cj,5j So ucth tc2o p 1 a Contact Person: 1 ! ,: a Summary of Revision: j)ui Revision& Sheet Number(s): t4m 3 A , N-m s H m S Access "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: /./ Entered in Permits Plus on 1applicationslforms- applications on Iinetrevision submittal Gated: 8 Revised: Phone Number: a 1O10'S7� AA /RAP Steven M Mullet, Mayor Steve Lancaster, Director MAY 31 2007 (:ENTER 4170 Project Name: Internap Summary of Revision: Contact Person: Jeffrey Pencek tapplications \forms-applications on Iine\revision submittal Created: 8 -13 -2004 Revised: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa.us ❑ Response td Incomplete Letter # _ ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Address: 3355 S 120 Place Revise Drawing M —1 Schedules ( 5 -2 -2007) Added Weights of Refrigerant to Schedule. Phone Number: 212- 681 -0200 Steven M Mullet, Mayor Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fad etc Date: 0 10q ` a Plan Check/Permit Number: - e M07 046 RE CITY p U MAY' (v4' 2007+ PERMIT CEN Sheet Number(s): "Cloud" or highlight all areas of including date of revision Received at the City of Tukwila Permit Center by:( D Entered in Permits Plus on License Information License HERMACLOO5BJ Licensee Name HERMANSON COMPANY LLP Licensee Type CONSTRUCTION CONTRACTOR UBI 602004844 Ind. Ins. Account Id PARTNER/MEMBER Business Type LIMITED LIABILITY COMPANY Address 1 1221 2ND AVE N Address 2 City KENT County KING State WA Zip 980322945 Phone 2065759700 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/11/2000 Expiration Date 8/25/2008 Suspend Date Separation Date Parent Company Previous License HERMAC•217NT Next License Associated License Business Owner Information Name Role Effective Date Expiration Date HERMANSON, RICHARD L PARTNER/MEMBER 01/01/1980 ALMON, KEVIN PARTNER/MEMBER 01/01/1980 MACDONALD, JAMES PARTNER/MEMBER 01/01/1980 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= HERMACL005BJ 05/15/2007 N N N 1 N N 1 II 11 eNtet MIME 1 0 1 1 a 1 c; 1 - r J • Arai MOM 111151141•1 1 0 1 « 1 gma 1 OdINIMMI ear r. r S ki \ , 1 0 \ \ \\ \ \ K 's ■■.1__.1..__._•,..61w.w,...wa.. IOW L _...._ .__..J 1 0 1 « ., J 1 0 1 0 1 J 0 0 • 0 0 0 0 0 0 0 1 Os • al— IMIIM MID :' 1 ;. 1 t:a k • • • V am. - - -..WE. i 1 " . . _ 0•1..: ••■••r..... _. 1.•._I • •&' .111•1 • 411111 Z J 0. V _ -- 0 • 0 CC u. "NZ 1)MY 1 c'1 1 • M .3 vir • • • At • RN AP 120th Noce iao 1 1 I • � 1 1 1 I iii i'l ,if eqj ii. -14 i i . i wish, I les' Ilihn; iiCiiiiii 1 lo ll moo sown 41,- Nov at , , �M 17� yore - 4R2 , NO OA I- . ;ide16®! i 1 a1 'Ono r NA on] i OYAH Ooo1J GUs F L- 8M� m 41 1 g ii I i giI raistm nmt� jai Comp Iftllom 1-1700 HIND r at iiilood HOOD Atiiiiiiiiii , N N N 1 N N 1 II 11 eNtet MIME 1 0 1 1 a 1 c; 1 - r J • Arai MOM 111151141•1 1 0 1 « 1 gma 1 OdINIMMI ear r. r S ki \ , 1 0 \ \ \\ \ \ K 's ■■.1__.1..__._•,..61w.w,...wa.. IOW L _...._ .__..J 1 0 1 « ., J 1 0 1 0 1 J 0 0 • 0 0 0 0 0 0 0 1 Os • al— IMIIM MID :' 1 ;. 1 t:a k • • • V am. - - -..WE. i 1 " . . _ 0•1..: ••■••r..... _. 1.•._I • •&' .111•1 • 411111 Z J 0. V _ -- 0 • 0 CC u. "NZ 1)MY 1 c'1 1 • M .3 vir • • • At • • • 4 • • • • ^,f It; JCI . \ \ ..... r • 1.1 \ 1 \ , . ♦ I .\ • 1..1. \ • . • , . w• �rr • •n •\ . \ ti r . .... . \ . . • In - .____._.• '1 , .1r1 • * No • . • • ti \\ 1. • • h \ • „... I • . ..+K I \ 1 4 i 5 \ ' \ L ,1 • � \ I •._ ` \ • 1 • 1 14.. • • \. • • '\ S .�' 1111 ,,►I _u \ 'L . • ' ..w •••• \ !i w 'w ..w — _ • w .... — w1•11.■■.. • ww*■1.. w- et `.. \• \ \\ \ .\ • • ) ; • �.i :\ S r A r•— uar w I _ � . , ... _... •• ..._,..,,,,,,,„.„..„.....,„„..,......-------,..,.....611166_____Vers".."'""”- ar / I I 7 �._..- -,- 1• __. I. n r— Ur r BACKUP, li h , ii �\ I ITI LOCATE BMS PANEL IN THIS PC)OM w : 1' Ti'r Rv L. n_.1 1.za rrrT T_? — I _ • II momimiim 1 `0 0 J ss j OF tl VINO 1x4' Z 1V4' *1 DA' o ,-48x22 SUP _v BE -„� I :0 1 cr • 7 77 St I Via 48x22 SUPPL ROOF MOLNT C O INN 70 BE - LCOR. (TYP OO�C.37 1 3R0 FLOOF HVAC I Umu SalMO.W. i T f 1_11 floymm o posir I ABBRBIATIONANDNIABOLS I on,.. ossur I rl- .1 I" F 1 I" j p 1 1 I I I 1 I 1 I I �. 0 . Hermanson UP 1M -31 ®01 IMIT ;o ;PTO a RN Al 120th Plow I Mt Rai SIIRIOI CI Ie•'- • • 4 • • • • ^,f It; JCI . \ \ ..... r • 1.1 \ 1 \ , . ♦ I .\ • 1..1. \ • . • , . w• �rr • •n •\ . \ ti r . .... . \ . . • In - .____._.• '1 , .1r1 • * No • . • • ti \\ 1. • • h \ • „... I • . ..+K I \ 1 4 i 5 \ ' \ L ,1 • � \ I •._ ` \ • 1 • 1 14.. • • \. • • '\ S .�' 1111 ,,►I _u \ 'L . • ' ..w •••• \ !i w 'w ..w — _ • w .... — w1•11.■■.. • ww*■1.. w- et `.. \• \ \\ \ .\ • • ) ; • �.i :\ S r A r•— uar w I _ � . , ... _... •• ..._,..,,,,,,,„.„..„.....,„„..,......-------,..,.....611166_____Vers".."'""”- ar / I I 7 �._..- -,- 1• __. I. n r— Ur r BACKUP, li h , ii �\ I ITI LOCATE BMS PANEL IN THIS PC)OM w : 1' Ti'r Rv L. n_.1 1.za rrrT T_? — I _ • II momimiim 1 `0 0 J ss j OF tl VINO 1x4' Z 1V4' *1 DA' o ,-48x22 SUP _v BE -„� I :0 1 cr • 7 77 St I Via 48x22 SUPPL ROOF MOLNT C O INN 70 BE - LCOR. (TYP OO�C.37 1 1 ROOF PLAN ACCESS OUTL i llF 1 i M Ii m I 1 I II i ! i . I Donn omuw I �� 1 I I I I I 1 • I 23 :: I fSl.• IM -5 ACCI I ermanson 1 � —' . oat eaiO• • Iel . I rtil ill IF � i RN AI 120th Pboe !P O 1 1 ei ; .44 Ai • • • s EJ 0 0 m 0 0 -1 rui GEF ..�.r•"••r• •.� r r.. . _ _ • - - - - . . — . u . . - - - - . - - . . � — .0 _ _ • — _..o GEF Q — — — - -g=2- - - OMOIMIMIMM iddedemyle NIP - O- -F- - --- GEF 5 -1 i • I 0) C 1 HUMIDIFIER SCHEDULE (FIRE-PURCHASED) BASS CF DESIGN: SPEC AIR MIT MAIZK MOM- :SUMER gg AIRFLOtU (CR7) VELOCITY (FFM) MEDIA EFF. ('A) E 4TERiN* AIR CONINIION LEAVM AIR CG!VIT N M4' EOLD SIZE REi`4aEC5 DB F U,8 r GRANS DB r U,8 7 GRAINS W M D iu1 -1 11424094INVA Ga 44800 521 1St 4957 491 53 51 468 4a DO ;0 58 NOTES 14115 -2 1TA2489400DA 0 44500 521 7'M 4957 491 53 51 468 45 CO ro 58 1411 -3 TTA2A95 017DA 0 44800 521 1St 4951 491 53 51 4 88 40 CO 66 58 14115 -4 IT A2405AOVOA 0 44800 521 79t 49251 491 53 51 458 40 120 66 58 1. 1T 5-5 TT 42 C 44500 521 TM 4357 ABU -- 53 51 468 49 Qo TO 58 NOTES - a 2'31"151DPIER 1156 CASING 4 CQAR PAX Ca:FF-.R DIST. PUPA G. BAL. ,CIA vALvE. ECG COATraG 04 . WIA OvEE° Q9. DRAN 1 BLEED, CURS TO t7ATQ4 ACU. LCO BTATER OJT .Orr- Cam., 55.14_I(84T, FOA 5 TC1i, FACTORY 1 LOSE 5 WATER PR.00F NSTuALTIa. v.4'LVE AND PiP116 TI.ROUGN SIDE CF i.N R 4 5D..., 4'CCE5$ LE PER E ECCOC= k. L r LNIM ICAURED 2. PROvIDE 8' GAACIERCOR 3. P =551.- DROP 4. STAK.E55 ST 5. NTLsNAL SlP'p Pi-V, 6. i AKE P II:ATER AND T. LOCATE ELEECTR'-C. 6 GTIVE €56 15 15% STA- ARD EFIC°1ry 039 NCO CL5. 6 Ads GRAN PAN FLOAT vALvE BLEB BLEED CCNN CTICN L PANEL ON 5 OF UPS /24C 5PL IT SYSTEM (FAN COIL) UNIT SCHEDULE BASIS CE DESIGN: MANE TAG LOCATION MODEL SUPPLY FAN COOLING COIL UNIT ELECTRICAL DATA FLOW (GFM) FAN (IaP) ESP (IN W.GJ SUPPLY (BHP) CAPACITY a•01-1) DB CF) iIIB (•F) A (•F) WB (•F) IMP REF 1.-FS VOLTAGE . CHARGE MR'S /AC 5 -I 11.011 UPS/AC 5-4 UPS / BATTERY ROOM r•GGE3021 10 0 10 15 9076 30974 / 23938 co 67 5823 5123 0 R22 69 LB 4 6013160 TAG Nat CAPACITY AM$IE T TEM CF) CQ•FRES5OR CONDENSER FAMI COWEN:5ER COIL oF CIRCUITS ..NIT ELECTRICAL DATA MOM- QTY. 1N1 QT Y DRIVE IMP_ AREA SF ROUES VOLTAGE FLA MCA 1.-FS ACO1 -1 T401.1 ACOJ 5-4 75104 95 - 2 146 /119 2 D:SECT 1 168 6 2 46013150 18 56 80 ¢ LIOC251 T.G- :.LET SIZE MX , 1 OFER '- e ; AX_ Cel :'OD =I VA 6 EO 2 2 4 0 500 CESI vLv -2 G's 32• WOO 2000 cs.91 v4v - -3 8* L5 6000 -- r.".= TL6 CR't WE I EcK $1 room QSMARiC,s 5..D-I 'CC- 24,24 41 Cr'7N• :.i -O 8E -100 2.75 6 - 1 - - 2- , - 60- yx -c-; Or=...5-.70. 5 AIM LOG. TTN 01%4N N :-c 01 5 ON r-E 3 P OOR r AIR HANDLING UNITS SCHEDULE (PRE - PURGNASED) .. 5 -1 RTU 5-2 RTU 5 -3 RTU 5 -4 RTU 5 -5 LOCATION DATA CTR DATA GTR DATA GTR DATA CTR DATA CTR MAX , O /A (a.R 1) ESP (IN W. C) MOTOR (I•IP) PRE - FILTERS AIR AP (IN WA) FINAL- FILTERS AIR AP (M W ) MEI ■Kt.Z1/1101•11 81)045c474 82X14 x424 82x140c424 82X141X424 MI O/A (CFM) 1460/ 145 496 1460 / 1212 145 496 1460 /t212 145 EL/ MAMFACTURER PACKAGED ROOFTOP AIR CONDITIONING UNIT SCHEDULE BASIS CF DESIGN: TRANE TAG AC 5 -1 LOCATION ROOF SERVICE 3RD FLOOR OFFICES MIN O/A (CFM) NIA SUPPLY FAN ( R1) 7.400 tN LW J 5 MOTOR • COOLING COIL CAPACITY ( 153 1 1254 2,400 vlx (FPM) 243 OB ('F) 12 D5 (•F) 5m CF) 41.11 AREA (SOFT) 989 FILTER r T13rdoj. A ELECTRICAL V / PH /NZ 460/3/60 MODEL TSC090A493 1401E5 L FROvIDE FUSED DDSCQ'AECT SU TDA 2. ALL E 1 P NT SHALL BE CONNECTED TO BM5 SYSTEM. COOLING BTU CAPACITY SPEC3:IEO 15 TLS NET OUTPUT BTU RECUIRED. SUBMITTED SHOP DRAWINGS OF A/C I141T CAPAGMTY WALL AE BASED GN WE NET OUTPUT BTU. GROS5 BTU WILL BE REJECTED AS NOT COrPLYING ul1114 SPECFTCATION5. L PROVIDE FIELD MOUNTED MIRED SMOKE DETECTOR N D1504ARGE AIR STREAM 2. 30% FILTER EFFICIENCY BASED 04 A544R.4 STD. 52 -16 3.00249_ IU DISCFwARGE, BOTTOM MILAN um l AIR GRILLE. 1 AIR COOLED CONDENSING UNIT SCHEDULE BASIS OF DESIGN] TRANE L F'RQVIDE LOUT A9'EJT COOLING OPERATION 2. 015CCNNECT SC1T04. 1 AIR DIFFUSER SCHEDULE 5ASI5 OF DEVGN: TIC 1. PRcheoF. CAM: MS PACKAGE )TU .3I °J Q TO ow. 2 P. LOCAL D'5CCANECT SOTO - EXHAUST MN SCHEDULE (PRE - PURCI-IASED) T AG- Gs 5- 1T.RJ5 - 5-1 : 5 -2 tr. 4EE�trg1 c- soc MODEL 666' 50440 -c CL I D=5G� ,nt '5900 2)200 2)900 FAN CR; FAN `?NCS'I)i CFI`'. 29CC• It \rL T5P WS t125 t�5 TP SPEED LI M 96 81 8i 1 1C3 103 DRIVE DI RECT ea./ &LT MOTOR DMA R TW E ELECTRICAL DATA VO_T5 F 14Z 20 GDP GDP 460 I'o 3 i 6a 6O 60 VFD USED ya 57 NO JPE.RATD6 maw 4)011 ICS 105 DATA CEN . 13ATITR ROOT BATITAY ROM CONTROLS AV) NOTES: 025PFW ura 160. vx TO 30.7 DlJSG OPRSTOY 1 vAV SCHEDULE BASIS CF DE5GV :TITlir NOTES L EXJSTNG ECIIIFFENT PERFORMANCES TO BE VE.RP1ED_ 2. ALL EQU1r ENT TO BE EOU1PED CUM TM CAPABILITY TO COM"rUSCATE WITH 13i UTOMATION SYSTEM. 3. CC.ORDNATE EQUIF1- iT 0• TALLATION III/ ALL TRADES. BASIS CF DESIGN: TRANE SEPARATE PERMIT REQUIRED PM 11 !Warta C'.1ftfT r BL.S- .D:N3 CYS"y0N AMMR No. Plan Wen s2F E abject b et % sTld crbays Npr L: daamarts does me 2t>.101's Me *Wag d .=1 b cede a' atrrart = 1. -vett szscw a Fr:'+ Cary a-d aoraCbare. 3 ad.-a e '')!'t. erfc % /r 7 • linSSUNIS e shall a made b Was c: . _'ate E)oa'.rClg ta+r= re.a. de :.3GCcrs1 6%x1: woo ran. V.J. CRYCIFIMNIA :r C FiftriO:N ER • AA OHTECT. CORTLAND OMARR MORROT AIA '11 h f watt ACM /4/1010N. 14.81 11.012 F1.0lE Iet/i 036•S6?S- FAa [6 * ►1 63.3699 Ti! NAY CONSULTANTS tt150 tler g Co.. Ss no Meas. Ta.as 15251 PROJECT c0a *AtOR HIGHLANI A880CIATE8 228 East 45d1 Sucre New Yak. NY TODD 12115 681.0200 12115 681 -0201 - Ea• s.l wiigtisrolass0(i2tes can New Ywic • New Jersey • Pems»fatia ' >aO.EC 9EE: �O 1 a.*OnG CCteEaTS 2 50.E0 PER Mn: 2 SS;E3 Wits 1 5S.E3 fCtt ..D►�. OESCAF MECHANICAL SCHEDULES M - 342: 222 3355 South 120th Place Tukwia, WA 98168 -16111 nartimp- 1 •1 1 1 1 1 tm• CON.-7.%.:5A1E DRA1t WILL TO OUT&DE SCALE i•.i• 0134 *...1714 PIM DAMFER • • _ (222 REFRANIT I sucTicti LS (2) RSRANT LICAND RETIM LIKSS (TYPICAL (4) LIMITS) OGIA115T UATI4 DArPER -4-N4-02:002 =00-1-7 PIPE V_•=1=1 (OO) UPS AND BATTERY iOON „r WII-E.cTIOSTAT NSULATED REFIZC=,2A. LesZ.-1 LP TO ASSOCIATE) ATe COOLED COACEKSERS a UPTI-MRMOSTAT 0 CV-7-.N.SATE DRAIN LM_= 1 1 / -13 x 14 MOMPER LOUVER (60) DA:PER COORDNATE RdFCSGERANT LS NSTALLATICN WITs• ALL TRADES 02.09...SATE MAK LKE TO EASt AvALMLE ORAN RECEPTOR (rrp. FOR ALL A 1143TS) DiSCPACrZ &RILES AT FLOOR LEVEL TO 51.PPLY A:52 TO AISLES 0-ERE r 1-"'T5 OF Lps. 2 A. FAC?.srs. 1 PECEVED,,_ CITYL.4- " 4 ;•:e; FffriATCE+WR anew I IC T CORTLAND ISORSAII, ARCHITECT, Alk HI N fieleee Roll Ashngtok Isis NOV istilyiE (seri 636.S696. FAx 11:171 636-Se91 PROACT 1:00roesatot TIE PURDY CONSULTANTS *4650 Menden INN.• Stito ?SO 041.1. lre.as 13251 HIGHLAND ASSOCIATES 221 East 456 Sweet New Yak. NY SOU (2112) 611-0200 12121 6111-0X11 - fait wnwhighlandassociates.com New York • New limy • Pennsylvania ■liNMENNE■•• KEy RAN APEA OF eiORK • • E Ctrl s2.2 3 *SAD KR se-neT 4.22 sv 2 :ME, FCR PETER 3-251 1 W.*, FOR Ft.PG DESVV:0 • INTERNAP* 3355 South 120th Place Tukwila, WA 98168 C3 OGICW r.fo ;:c gas a. is WV:CI OE ,F4 S I slreMler milm UPS & BATTERY ROOM 1ST POOR r E.9 L 11EGI -I_ ' F01 17:=2.-1 I CI 1 LOCATE °4 Ti4 ROOK 'J' SATtRY errQ_ INN 8M5 PANEL VEST_ SEC_ Or OFFICES J 5trR_Y Ot1GT . . . . .. DOAN TO BELOW RA15=_D • • FLOOR errp 1. ELECTRICAL- ROOM - - t-1 . . . . - 1 : 1. 1-f DATA CENTER .. . ; E 413x77 5t.TRoLY DI.CT STS ROOF rOxTe, DOCII.7O'xic 0034 TO Moe: : R.OGQ TTTP) 1.1 DATA CENTER AND ELECTRICAL Roos' i AIR DISTRIBUTION Sc a _1• Ed e 1 - t - • - 1 - t 1 (1131) 24)24 55% OPEN PE1tCRATED FLOOR TILE REFER TO A1R9-011 DI4GR N ON DWG 11-14.4 FOR FOR DATA CENTER R.\ ELECTRICAL ROOM. • V MOT-0LP C l 413 � APPROVED MLR- ;UV C 4 iti k PERRTGENTER I a s : y +t 1 r 1 t A )-- % `, , oS O1,NTERNAP• 3355 South 120th Place Tukwia, WA 98168 CO RTLAND NOUOAIt AaCIUIIOT, MA Tn 11 Foie► Reef Arupral Ties r60+2 PHOs4 Nal 63•:696 FAx 16171 6168EY1 TNTt SUNDT CONSULTANTS ,e6so l Ol lfOfl Om* Svro 250 Deus. T.•as f523s FAOfcCI wonoMATOR HIGHLAND 'my RAs AIEA OF boric AROHtECT ASSOCIATES 22* East 45th Street New Yak, NY 10021 12121 651 -0200 1212 651 -0201 - fax wwwlighiandassociates.can New Yak • New Jersey • PeonsArasia ▪ aUttOwc aEPT MOMS 5.c -cr 3 GSA° FOR 7E,a6T e-ra 2 SAID FOR Was ) 23 • SSA:0 FD; RAG 3347 w •kS C* ;e i_ MECHANICAL DATA CENTER AND ELEC. RM AIR DISTRIBUTION. M -3 1 r J SCALE " =1' 1 Ell 1111 9 1 . 8 (250 CRT) 22X36' RETI.RVI AIR PLEWIT '(225 M5 C+31) I ^) 8 - • 1 1 24)04 RETIL@N GRLLE(TYP -B) 250 CR 1) tra OT:) 6 (ris SCALE v4' .eLV -3 6c• . 223"Ap SUPPLY NICE (>a0 CR 1) DATA CENTER AND OFFICE SF'ACE ABOVE FLOOR AIR DISTRIBUTION 223T36 MT L.. L Q PLe'W'6 TO £G 5-1- 2' LINEAR RETURN( DIFFUSERS WITH L1G ITSH:ELD (2;5 (2 • A 111 El IJ [1 I I 1 o II on EG ATE RE J DATA CENTER . AIR GRILLE (TIP) 1-Im 0 - --1 D E 1 _ 1 (22S CI I ° . o� ono Ell 9 Ill ono ! o I . . . I 1 .. I ,. ...2.2 . ... n n. l• i 11 urn. 1 1 -3.2.1. 64 CCHNECTION TO • Y£ > ..c3 -: D O D D N • • ELECTRICAL ROOM J VLY -1 240 G*'+ /6 u (225 Cn T1 7 :,..NEAR RE=LY OFRZE.QS Lr.3 1 = • OFFICE SPACE ABOVE FLOOR AIR DI3 T RIBUTION (ENLARGEMENT) ❑ 0 64 CO*T:ON TO Y LINEAR DIFREE" Q (TTP • 31 i 3- Y LIVEAQ0 (t30 Cn .. EA J n t t t 1 1141i1111 sutra 0 • CONSTRUCTION NOTES: 51EETMETAL DUCTWORK. A ALL oucn oRK AIR C/IAMEERS. CASINGS. ENCLOSURES. DAMPERS AND ALL AUXILIARY DEVICES AND WORK NECESSARY TO MAKE TIE VARIOUS AIR CONDITIONING AND SAT�ISFACTTCR E TIC/4. SH AND 6E I U5 READY AND INSTALLED. LO G CUAALIITY.1 GALVANIZED V MC COAT OF 133 Z. PER SA. FT. FOR EACH SIDE IN COhr-CITS1ANC.E WITH ASTM A9O. FABRICATE AND SUPPORT L DUCTWORC IN ACCORDANCE SUM SMAONA APPLICABLE DUCT CONSTRUCTION STANDARD AND ASHRAE HANDBOOKS EXCEPT AS REIVORCHG mooriED SEALING PROVIDE DUCT MATERIALS (CLASS c) R IN 2 PRESSURE CCLAA 6FIIC D IVE OR NEGATIVE. CR AS PROVIDE ACCESS DOORS TO AU. CONCEALED CONTROLS. FUSIBLE LINKS. OsJIPERS ETC. PROVIDE MAP/JAL DAMPERS N EACH SPLIT OR TAP CONNECTION TO TR3AK DUCTS FOR BALANCING PURPOSES. EACH PROVIDED WITH OPERATOR AND LOCKING DEVICE. ANGLES AND OTHER STRUCTURAL SHAPES USED IN C NSECTJON WITH BOTH STEEL AND ALOTIN 1 SHEETS SHALL BE DIAMETER ZINC- COATED STEEL. HANGER SHALL CE 3/8• MiNPT1M HOT ROLLED MILL STEEL. PROVIDE RRE DAMPERS A NDIOR FIRE -SMOKE DAMPERS WITH ACCESS DOORS MERE SHAUN ON DRAWINGS. FIRE DAt1 ERS SHALL BE 'RJ6KN" OR AS APPROVED. DAMPERS 5WA MEET THE REOUIREPENTS 4 NFPA BULLET/1 NO. 904 AND GC/VERO* WILCO* CODES. INSULATED FLEXIBLE DUCTWORK WITH VAPOR BARRIER MAY BE DIFFUSERS. FLEXI TO BL DUC SMALL NOT E 3 FEET IN LENGTH, WITH COnSTRUCTION CONFORMING TO NFPA 90A Alb UL181 NSULATED FLEXIBLE DUCTS NML MATED FIBERGLASS FABRIC SUPPORTED BY HELICALLY UJOtND SPRING STEEL. WIRE OR FLAT STEEL BANDS RATED TO 3 ITCHES 111'i POSITIVE AND 16 INCHES UJG NEGATIVE (RAPPED WITH FLEXIBLE GLASS FIBER 8d5U.ATIpNI. ENCLOSED BY SEAMLESS ALUMNtf7 PIGMENTED PLASTIC VAPOR BARRIER JACKET MAX11131 VALUE AT 15 DEGREES F. J. DUCTYIORK LAYOUTS AND ROUTES AS %NOUN ON TIE DRAWINGS ARE SCHEMATIC. CHANGES H DUCT SIZES AND/OR LOCATIONS SHALLMt4DE WERE NECESSARY TO COFOR1 TO SPACE CONDITIONS OR TO OBTAIN MAXP13'i I€ADROO I CONDITIONS WITHOUT ADDITIONAL COSTS TO THE OUTER MINIMUM DUCT GAUGE SHALL BE 11INRIUM• AND NOT LESS THAN' 24. DRIVE SLIPS ARE PROHIBITED. COORDINATE WITH ALL AFFECTED TRADES TO ENSURE THAT NO CEILINGS. ECUI1 PENT OR OTHER MATERIALS OTHER THAN AS SPECIFICALLY FRONDED HEREIN ARE SUPPORTED FROM DUC1WC ( OR TIE DUCTWORK HANGER SYSTEM JOINTS AND SEAMS SMOOTH CH TIE INSIDE NEAT 5H O TIE cursive. DUCT JOINTS SHAU. B A ALQTIGHT WITH LAPS MADE IN THE DIRECTION OF AIR FLOW AND NO FLANGES PROJECT/4G NTO THE AIR STREAM DUCTS SHALL BE ADEQUATELY BRACED TO PREVENT VIBRATION( PROVIDE ADDITIONAL BRACING /HERE NECESSARY. ALL JOINTS 94ALL BE SEALED USING DUCT SEALER 5r11LAQ TO FOSTER 32 - 50 REGARDLESS OF PRESSURE CLASS. PROVIDE AN AIRTIGHT FABRIC NECK AT THE OUTLET CONNECTIONS OF ALL AIR MAINDL/4G UNITS. NECKS SHALL NOT BE LESS THAN 3' NOR MORE THAW 10" ti UADTH AND BOTH SIDES SMALL BE SECURED WITH CRIMPED LOCK 5EA145 ON TIE ENTIRE PERI'ETER WTH GALVANIZED STEEL SHEET BANDS 3 WIDE. NECK FABRIC SHALL BE CLOSE OCIvEN OUS' E5 PE SQUARE YARD comm. 28 CODE C° APPROVE - 01% ..e er a : �'fnU v .4TER AROII(Cr °OSTIA'S NOww * AMCIITIOT. A1A ?et N F»tbr Ross blrptaa. Taros T69t? VHCI [amT/ 6365696. FAX 161I/ 676.5639 f6fitefEA T_ MDT CONSULTANTS t4830 Walton Deno Suds 259 Oasis. Toms 75214 FROJECr COOItD1111IOR HIGHLAND ASSOCIATES 228 East 45th Street New Yak, NY 10017 (2121 631-0200 1200 681-0201 - fax tiwwh#iatldassociates.com New Yak • New Jersey • Pennsylvaria a a1E0116 OE?I CDR %TS 3:247 3 55[7® FO/ Prow a i•- :r 3 59.0 FOR ?EYES 3 s cz t 1 ST E9 FOR RAG 3 v:: .D OESG'aF -u C SEAL '' f OS PV ECT 946T 10 r z 3355 South 120th Place Tukwia, WA 98168 *; i.:C74 CA 7 E carm:7 :.-• • V-S 04E s Sca;: "8• , • 9EfTc:E M -4 MECHANICAL DATA CENTER AND ELEC. MA ABOVE FLR AIR DIST. 1 1 OFF5 T BELO.1I ROOF LEVEL TO LL1G4 68114 DATA Ce - TITER WALL l EciTiNG 2• Cti l . : 44• ►M/ 82* 4C 5 -I • ►�� I-u15 -3 RTU 5 -3 • • • • • • •• •• f=F 5 -1 •• • •• •• • •• HJ MU 5-5 14.11 5-5 ► 641`6 5-2 RTU 5 -2 •• • • • • •• •• G3.5 -2 ROOF EQU PT DENY LAYOUT PLAN SC.4E.E 1•=1 Gs 5 -3 (16) 2 -41) ALLAYED RouraGERANT SUCTION Liles (16) INSULATED RGEFRIGERANT LIQUID RMTUR+1 L6ES FR01 UPS /AG5 -1 TI- M.1 4 SERv C 1G UPS/BATTERY ROOM BELOW. ►� ACctl 5 -4 ACLU 5 -3 ACOJ 5 -2 .CCCU 5 -1 820 *MI ► 1-621 5 -1 RTII 5 -1 RTU 5 -4 6202 56 DSCPARW DUCT CCN'CT TO 56x: Iti'T 581: ER 1- 10.S210, ADD 96x12 5A DUCT S 1-tin VDT-.ER TO t'A1i 86•6 Duct' [TYP) NOTE: CONINBICT APT 50P .ER TO DCBT3 C.= PPE LOCATEEsD' CK 100CF. 'HELD VE.q Y CC NECTI.GKS PR'OQ TO ►� • •• •• • •• •• SEE DETAIL C 5 -4 REFER TO 3 REVIEWED FF R r com C OMPLI n N .L APPROVED I _ z • ,,•r .... Akof-woil Of Trt -- �: • CSIYOF PCIASICEigai ARQITECr. CORIUM I ORSAN, AMMO. AN 1n N F.MNr Rcy Arleyr.•. T...s 860•2 PH .€ I6t11 636 5696. FAX 1681! 636 !693 E11GNEER 111 lURDY CONNILTAIRS rs630 ./Omer- oh.. Srr• ?SO Deis. T..Os 1523• PRO4CT COOR0*11OR HIGHLAND ASSOCIATES 228 East 45111 Street New Yak. NY 1000 12121 661-0200 1211} 681 -0201 - fan wwwligNa rfassociaTes.trrm New Yak • New jersey • Perncyfraria Set ;ME i s ik 3355 South 120th Place Tukwila, WA 98168 C/1 0 3 PI'S o r y VAI "3 : C MECHANICAL ROOF EQUIPMENT LAYOUT PLAN M -5 r CUT AND CA.° E)C$TACs G:i l 3' X 5 T - Y s Ts-R.1 . _ - :NG Mr AND EA.0.03 E)GTNiCs 2• CJ 1 1-.1.11 5 -3 N RTU 5 -3 00 0 00 0 0 At; 5 -1 5 -1 1{5l 5 -2 8111 5 -2 0 0 5-2 C� 5 -3 CONNECTION SIM TO / P . FOLLOJ i ZL'RJGTLI STALL. TK.e; �STQIGr 'S. i 6mcuua1iS. (TYP -.CAL 5) MEC4ANICAL ROOF PIPING PLAN 5c.aLE k =l• E E T W T W T AGGU 5 -4 ACOJ 5 -3 ACQJ 5 -2 ACQJ 5 -1 1115 -1 RTU 5 -1 0 0 eeo ee RTU 5-4 62x1 5d CILSOURC DUCT COWECT TO J 5b700 Ii215 :ER 1 ' ADD 96x13 se. DUCT Mal l 1 t.; 5:D3- :OMAN 86•. DUCT (TYP) NOTE: C.O.N={T 11)1 S:DF.R TO EX:S•.' GiAi R PIPE LOCATE O4 GOOF FELD 1FQFf PRO.Q TO G 5 -4 CONNECT TO 65 111. 2' 0.1 `a1 2' Q:1 CAP EGSTING 2• CJ Bit Aitot-04 RtVIEWE75 ► - ApPROti.SG CITVOFTUPOISIA NY 0 4 No AROIIEC 00111Lw11D NOONAN, A T. AA 1I1 N Elder Reel All ICo. Toss 26012 PwQ1\E 16.11 6365696- FAX Ibtp 616 -5549 E 1I IR PROJECT C0000011051 HIGHLANI ASSOCIATES HS it 4Sde Street New Yak, NY TOAD 12121 651-0200 1212) 651 -0201 - fax Ihwwligliandassociateicom New Yak • New Jersey• Pemsylvaria KEY FLAK .•••.......... S1$: ;"le ?f! MDT CONSULTANTS Ne63o Montfort G.o sore 250 Oeeas. Tees 1515e AREA OF voOlar 0.. 6 Ba IG r7E7i COWas 3 6S+E1 Fryr P15 I' 2 FOR AMR • WAD F04 RAG *KA:71G 1'7t'•:'2 CAI C•IICT/V OPa101 •fT si'6 0E0•0. O. 1p SCALE ' /d' - MECHANICAL ROOF PIPING PLAN M -6 INTERNAPe 3355 South 120th Place Tdcwila, WA 98168 r i 1. 2. 3. 4. 6. 1. s1ENiFRAL NOTES THE CONTRACT DRAWINGS ARE SCHEMATIC AND ARE INTENDED TO CONVEY A RJICTIONAL REL OIL SYSTEM AND TO DEPICT TIE GENERAL. LOCATION OF THE SYSTEM COMAOENTS. CONTRACTOR SHALL EXAMINE TIE CONTRACT DOCUMENTS AND SHALL FAMILIARIZE I4 15ELF BATH ALL THE IZEW'REMPTNTS OF THE PROJECT AND SHALL NOTIFY THE CONTRACTING OFFICER OF ANY OBSERVED FAULTS AND AMBIGUITY N THE CONTRACT DOCUMENTS 50 THAT THE MATTER MAY BE RESOLVED PRIOR TO SUBMISSION OF BIDS. BY SUBMISSION OF BID, THE CONTRACTOR SHALL ACKNOWLEDGE ACCEPTANCE OF THE CONTRACT DOCUMENTS AS AN ADEQUATE DEFINITION OF THE SCOPE CF WORK AND EXTRA COST CLAMS BASED ON INADEQUACY OF CONTRACT DOCUIIENTS WILL NOT BE CONSIDERED. ALL WORK ON THIS PROJECT SHALL BE INSTALLED N ACCORDANCE WITH ALL APPLICABLE COKES AND REGULATIONS. CONTRACTOR SHALL THOROUGHLY CLEAN HIS WORK AREA DAILY. MECHANICAL CONTRACTOR SHALL ALSO REMOvE ALL TRASH AFTER COMPLETION OF WORK. CONTRACTOR SHALL VERFT ALL DIMENSIONS AND LOCATIONS FOR PROPER EQUIPMENT NSTALLATION PRIOR TO SUe 1ITTNG EQJIPMFNT SHOP DRAWINGS FOR APPROVAL. CONTRACTOR SHALL VERWY ALL VOLTAGE AND POWER REGI METSe'THTS AND COORDINATE WITH ELECTRICAL CONTRACTOR AS REQUIRED. S. ALL SYSTEMS SHALL BE CLEAN OF FOREIGN MATERIAL AND [TOUGH SPOTS PRICK TO BEING PLACED N SERVICE AND BEFORE OPERATIONAL TESTS ARE PERFOIe•'ED. •. THE CONTRACTOR SHALL LOCATE ALL EQUIPMENT 1114104 MST BE SERVICED. OPERATED OR MANTAI NEED N RLLY ACCESSIBLE POSITION EQWFt ENT SHALL .1Y-,LLCE, BUT NOT BE LITTITED TO. vALVES, TRAPS. MOTORS. CONTROLLERS, ETC. t0_ CONTRACTOR. StECONTRACTCRS AND MATERIAL SUPPLIERS SHALL BE RE FOR NSFECTION OF JOB COt PTi0N$ AFFECTING THE INSTALLATION OF 4N ITEM AND FOR TAKING ALL FIELD MEASILREMENNTS PRIOR TO THE FA5.RCAtION OR PURCHASE OF THE ITEM r0 ENSURE THAT TIE ITEM CONCERNED LULL INTEGRATE PROPERLY 1111114 ALL ADJACENT MATERIALS AND WILL FIT ALL OTHER CONDITIONS AS THEY EXIST CR WILL EXIST N 11E FINISHED BUILDING. SLEEVES, ANCHORS AND OTI ER ITEMS THAT MUST BE BIKE - DIED NCR THAT OTHERWISE AFFECT OTHER PORTIONS OF TIE WOW SHALL BE LOCATED AND SET WHILE Woo PORTIONS OF T►E WOW ARE N PROCa.RE55. IL UNLESS OTHERWISE SPECFICALLY MENTIONED, ALL ANCHCRS, BOLTS, SCREWS. FITTINGS. FILLER. HARM/ARE ACCESSORIES, TRM AND OTHER PARTS RZEQU+RED FOR CR N CONNECTION WITH, AM ITEM OR MATERIAL TO MILL A COMPLETE, SERVICEABLE, FINISHED AND FIRST Q)ALITY DSTALLATION SHALL BE RRNIS1 ED AND INSTALLED AS PART OF THE ITEM CR MATERIAL, WIETHER CALLED FOR CR NOT. 12_ UNLESS OTi•E. J.SE SPECFICALLY MENITCAW, ALL ITEMS AND PARTS THEREOF THAT ARE MADE OF STEEL. IRON OR OTTER FERROUS METAL THAT ARE NOT GALVANIZED. PLATED OR OTHERa1J5E SPECS ED TO BE FACTORY FINHSIED SHALL BE CLEANED AND PANTED WITH ONE COAT OF BEST QUALITY RUST NIIEB1TIVE METALLIC PRk ER AFTER INSTALLATION, ALL EXPOSED ETAL CONNECTIONS AND ABRASIONS SHALL BE TQiG.ED -UP WITH THE SAM MATERIAL AS THE SHOP COAT AND LET N GOOD COI sVItia+; FCR FNAL FIN514i. . F fQJ:RED_ 13. ALL ITEMS SHALL BE INSTALLED N A UI0I0Q1ANLKE MANNER N STRICT ACCORDANCE BATH THE BEST RECOf34IZED PRACTICE N THE FIELD =INCEPTED. MANUFACTURED ITET SHALL BE ISTALLED N STR;;CT ACCORDANCE WITH TIE M4NLFACTU.MR'S PRxNTED DIRECTIONS. SPECPICATIONS AND/OR WRITTEN IZECOhi'�19AT1CNS FCR AN INSTALLATION OF 14'1GJ[E5T QUALITY. ALL WC.QCINCI PARTS SHALL BE PROPERLY ADJUSTED AFTER s1'STALLATRON AMID LEFT N PERFECT UJORECNG ORDER. ITEMS N ALL CASES SHALL BE INSTALLED PLUMS, 1•ME AND N PROPER RELATIONSHIP P TO 5L:'PROUN"DNG MATERIALS. 14. MOTOR CONTROLLERS (STARTLR52 CR COM$:NAT7ON STAQTE.R DISCQ.N -C T SWITCHES FOR MECHANCAL EQUPI r" NT ARE R.RNISt- D UNDER 11415 DIVISION AND INSTALLED MEIE.e DIVISION IS MOTOR caaRoLLERs SHALL BE COMFLIAVGE ILITH ARTICLES 430 AND 440 OF THE NNAT/C :AL ELECTRICAL CODE. COORDINATE WITH D1V SIGN'& L TI'S DESIGN CRITERSA TOCeTI. R LEITH TIE 5�.°PLETEtTARY INFORMATION LISTED HERE L' AND SPEC F.CATION GONERS TIE EQU:P 4T TO ea USED 1 THE MANLFACTILIE AND A'STALLAT:O 4 CF ABOVE GROtAD REL OIL TANKS AND TIER CONNECTION TO 5 t � '1NCY STLNDSY PO:ER GAT O E. SYSTEM THE MAN OB..ECTIvE 15 TO 1 vDE AN AUTOMATIC UNATTENDED IELIABLE REL 5TO?ACE 5Y5TEM, 2. F=ADERAL. STATE. LOCAL AND OCA.°AT!0N L SAFETY AND I. T:4 ADI : •STQATION (OSHA) STANDARDS SHALL BY RLLY COMPLIED. 3. THE USE OF TAWS MST PR iE A SAM AND EN1/..ROINZ- :ATA.LLY SOON° STCQAG SYSTEE; - L R 15 E55 4TIAL THAT r-AP -RES FOR IZELIL J Irr SALTY F GZE PROTECTION. EN AR t \' T. L PROTECTION, STR.ICTI.RAL \'TE JTY, AND ISOLATION LL PEE DCO.R=DRATED %-N? £DC 4 - FRO ER: SC4N5 AND DECALS 5 SE LNSTALLW. T+ _ la/oa0 E OF THC 5'C: 4 GE 15 TO ADNA.%E OCCMPL \TS TWAT OPEN F;L 'ES AND ST'O NIG £ PROASAT L ITHN AND AROUND TH-E TANK AREEA. CO'7RLY LOTH LOCAL. STATE AN, FEDERAL CODE5 5. ERACNG AND 7ECE55LeY P DOBLE CONNECTORS SHALL BE I5T&LLE✓ TO EVE. DL =ACe TO TR.zrR PPNG OR TANKS. 6. . 80 #E acztho STCRACIE TANG M •LVFAC1.eN6 RrEpL; TS A TANKS S%TALL CARRY A UL :.2 L15TYG AND CCAFOR •; TO ti PRO /SO■'S OF UL !AZ AND INFPA SECTION NO. 30 .r-.'. - TO TIESE STANDARDS SHOED D PQ: Y t T-E SASS FQe cI+NG- 1FPLtCA3LE REGLLATONS A•80V£ GROUND PEE. 5TORAW SYS.r S_ 140 EvrR LOCAL CODES OR ESC: LArCN5 MAY ,.mac : lR S'R.VL -'NT AND SOLD EE ! V=_ED DURING CE56N: a T TANK WALL .L BE CF DO.SSLE MALL CONS; R1JCT=JN INGLL0,-N6 .',N LNVLLLQ 5P1 FOR EAR _Y LEAK C =i ✓`CN AND : ON'TORN6 G. STR.;cr.RAL CALGLLT OG4 SHILL BE Pfi!.1 .0 SY T :1•LFAOTLREZ TO N0c A T.JLT THE ABOVE 64OI.N7 STORQ:G: vES5E= EET5 ALL AFEL•CABLE COO ES. D. ` M'•.N:1AI 3C- YEAR '-,:-'QRLNTY S./ LL SE PIJIL^1/tt� BY )11-E TANK M'LVF.'.CTLJ EQ E. ATINT-1.3 2- H0.Q F.RE RLT G - H I NG E 081.E SHALL BE PRO/CW COUNT Z Ga'�C :-T= C&GLA`O.5 OR ACTUAL ST DATA S-OLD BE LvLL%BLE PQCQ TO SE ECT'OA TANK T :'°E AND :.LV F. Gr Rt F B1.3T - OvEQE'_L °R:7" =C+ 0+: SH i °JE °4^/ . i : M' \"Li`: CAPIGt1 y !f F: F G%. L 6 CR 15 .R`O:RED SY LOCAL OR F=�_.R.=L G ALL .STALLS TANKS SHALL °..EERY TO CONFOR4 TO NFPA 5�I % 3A FN. SHOW W TEE' E AT LEAS: 2 FE ..40E GR=Cy SZJ�C.OF L?r05PI IG 1NO!BtA.) •4SV"S .S' a N ACCCRJL4 - ai m -a N?PL 'O N _ O°ERA T LAG PR=5&RE5 SE OI:+ 25 PS% 7.0 RcEJI. N :). - $1: 5`ZE LN . L00LTO% BE D-DeS :E'% OV ILK CONSTR;:CT01 LND OJARACTERVCS OF T-€ MATERIAL R'IENG STORED. DE.4 . VENTING. CAS US Fe3 ;'i:5: ALSO a ACCONT FOR N :•.E DESC>i1 AND CONFOR TO NFPL SEC' 7.04 NO. 3 AND TO t:L F43 6 csr.=^tiCY VENYKg FOR -E A ERs=•: •AL SPACE Qr a'XiX E L; &.C.ED TANKS MAT ALSO i?c PRD/O . H% ;- c.ALNCAL CO.'QACFOQ 70 INSTAL_ 2 NEU VO4L'GE 71AIK 6,420SS0S3BLE PJieS P;�- BY 0= -Ela I. "E-�,r LNC1l CO% =Jew 9 .s-' AND ALL !Earl P.? P COr'RICIL5 DEL DAY TANNIC SEQUENCE OF CPE!MAT - L CONTRACTOR SHALL MAKE ALL NECESSARY COO•€CTICNS FROM THE SUPPLY AND RETURN PIPING TO BASE TANK CONNECTIONS. 2. EACH BASE TANK HAS A FILL. PIPE MANIFOLD WITH 24 VPC NORMALLY CLOSED FILL SOLENOID VALVE AND NORMALLY OPEN EMERGENCY S iT DON SOLENOID VALVE. FUEL OIL CONTRACTOR SHALL RJRN19H PIPE MANIFOLD AND ALL NECESSARY PIPE FITTINGS AND CONTROL COMMENTS, PIPE MANIFOLD SHALL BE INSTALLED N 65. WATERTIGHT. VENTED ENCLOS.sURE WITH HINGED LOCKABLE DOOR. 3. TIE INSTALLING CONTRACTOR WILL 35TALL A CONTRACTOR 51.PPLIED FUSIBLE L61( VALVE AT TIE 544GLE SUPPLY PORT_ 4. PROVIDE A FLEXIBLE STEEL BRAIDED 1406E TO CONNECT TO TIE BASE TANK SUPPLY PORT. 5. PROVIDE A OvERERFLOW MVP AND FLEXIBLE STEEL BRAIDED HOSE TO CONNECT TO THE DAY TANK OVERFILL PORT. 6. EACH BASE TAN( WILL INCLUDE VENT CAPS FOR: - TANK NORMAL VENT - TANK EMERGENCY VENT - RUPTURE BASIN NOp1AL VENT - la1P1UQE BASIN EMERGENCY VENT 1. THE NST6LLNG CONTRACTOR 15 TO PROVIDE TIE REQUIRED PIPE AND FITTINGS. 13. EXTEND VENT PIPES E FT. ABOVE GRADE. THE SUPPLIED TANK VENT CAPS ARE TIE! TO BE INSTALLED CN THE ENDS OF THE PIPE. S. THE NSTALLNG CONTRACTOR 15 70 PROVIDE AND INSTALL THE FUEL SUPPLY ATND IEETURN LINES FROM THE BASE TANK TO THE ENGINE 10. SUPPLY ANO RETURN PORTS TO TIE ENGINE USING 2' APT WITH REMOVABLE 314' 1 T ENGINE SUPPLY AND RETILQI TUBE SCHEDULE 40 PIPE (GALVANIZED PIPE 15 NOT BE USED UPER AMY CIROIJ1STANCES) TIE CONNECTION TO THE ENG:NE 15 TO BE MADE USING TIE FLEXIBLE FUEL LINES SHIPPED LOOSE WITH THE PACKAGE. 11. REL OIL SUPPLY RJ'P< ARE RATED 13 GPM 50 EACH AND INCLUDE A 15 HP I6 VAC SINGLE PHASE MOTOR EACH PLJ"P 15 SEMI FOR ALTERNATING OPERATION. 12. TIE MULLING CONTRACTOR SHALL PPE OVET4s1LL RETURN. PIPES TO MAIN TANKS AS SHOW 13. EACH BASE TANK 6:CLUDES OPERATION LIGHTS AS FOLLOWS - NORMAL FILL ACTIVATED - LOW KIEL LEVEL - CRITICAL LOW RJEL LEVEL - HIGH RJEL LEVEL - CRITICAL 141G14 MEL LEVEL - OvERFLOV FUI'l* at EACH ALARM FUNCTION INCLUDES DRY CONTACTS FOR REMOTE ALARM 14. EACI4 TANK NCLUDES A TWEE POSITION •HAND/OFF /AUTO• SWITCH FOR CONTROL CF THE • OVEFZFLOW RETURN!' PtPGPS. 5. EACH TANK NCLUDES A *PRESS TO TEST' SIJITCH FOR MANUAL FILL AND FOR TESTING LIGHTS FUNCTION. MOAT AND ALARM ACTIVATION LEVELS: ELECTRIC IMMERSION TANK HEATER PROVIDE FOR EACH MAN TAW (AST) ORCMTALOX FLANGED INVERSION HEATER SIZED AT 80 ICU HEATER EVA MOISTURE EXPLOSION RESISTANT EN7CL0WE. TIE ELEMENT i$ERTION LENiCsTH 13 44'. TIE CONTROL PANEL SHALL BE NE"MA 4 DYL051J.RE AND SHALL ACGOMODATE TIE HEATER CAPACITY_ TI•E (EATER SHALL OPERATE TO H'IANTAN THE TEMFERAMIRRE OF TIE FUEL 04. N THE MAN TANK AT 50'F IS PROVIDE COMPLETE 5140P DRAM* AND SEG.EVCE OF CPERATIO.'S TO ENGINEER FCR REVIEW AND APPROVAL. 19. !NORMAL OPERATION (ASSUMING A FULL TANKA UPON 8611 FALLING. THE INDRMAL FILL' SOLENOID VALVES AND AVE EINERGIZED. lel ADDITION, TIE •ICR1AL FILL ACTIVATED' L LIGHT 15 ACTIVATED AND REMOTE CONTACTS CLOSE. (FON TOM R THE 'NOs'd1AL FILL' FUNCTIONS ARE DE- ACUYATED. 20 LOW LEVEL RNCTIOI: F TIE TAW CONTNJES TO DROP THE *LOW LEVEL' St4)TOOO)1 UJLL ACTIVATE AT 5% FALLING. THIS FUNCTION' WILL L 514Ut DOiN TIE DAY TAM AND CLOSE DRY CONTACTS M ICCH ARE TO BE USED FOR REMOTE AANJNCJAUONN AND SLIT THE GENERATOR SET DOWN BEFORE IT 15 STARVED FOR FUEL AND CAUSES DAMAGE TO TIE RJEL INACTION! SYST 1_ TIE SMJTDOUN 15 TO BE INITIATED THROUGH THE ORATOR CONTROL SYSTEM BEFORE THE ALARMS CAV EE RESET AND TIE CCRERATCR RESTARTED, TIE CAUSE OF THE SHUTDOWN MUST BE CORRECTED 2. AND THE TANK MUST ES TILLED TO AT LEAST 25% U536 TIE 'PRESS TO TEST' SWIT04. • -F05 -4 • - FOR -- G H� FCF -• AY D `6J cks 00 U 671130 LIST RJEL OIL SUPPLY PIPING REL OIL RETURN PIPING FUEL OIL FILL PIPING UNION PIPING PITCHED N DIRECTION CF FLOW CONTAINMENT PIPE ND/C4TES DRAWING NOTES BALL VALVE SOLENOID VALVE FLEX CONNECTION THERMOMETER MOTORIZED VALVE AIR VENT PRESSURE GAUGE W/ COCK Mirk PIPE UP DOUBLE LINE PIPING BALANCING VALVE BITTERLY VALVE STRAINER Y- STRA!ER v1S! -GAGE (SITE GLASS) CAPPED PPING FUSIBLE LNG VALVE CONDUIT AND CERNG FLANGE BALL VALVE wCQK BELOJJ GRADE ALLY CLOG> SOLENOID VALVE CHECA VALVE PIPE 71..e■a" ON P;PE TURNED t GATE VALVE DIS'LEX 5TRA R C,ONTA.NT .NT PPE A55LY AC. AFF APO AFPROX ARCH /ARC A.S.T. A7R BFP BHP BI BLDG BTUI1 CD CENTR CR1 CIO CONIC CON =NT DESIGN CN DWG ELEC ELEv ENT ESP EWT F. FD FL LEX FOS FOR FPM FP5 FT FO. FA.V. FOR FOP_ GA GAT_ G4V GR1 WORM HP 1R HvAC ID. TUG IOW LAT 15. MAX MECH M45i•1 INN MITI N. N.C. N.O. ANC No OA PD PLBG PSWG) OTT READ RPM 5J? 5TL. TIP v. KE, IJ STL_ ASSB"IBLY INDOOR AIR CONDITIONING 1.6117 ABOVE FINISHED FLOOR AIR PRESSURE DROP APPROXIMATE ARCHITECT, ARCHITECTURAL ABOvEGROI.1O STORAGE TAW AIR TEMPERATURE RISE BACK FLOW PIEVENTER BRAKE HORSEPOWER BACKWARD NCLTE° BUILDING BTU PER HOUR CEILING DIFFUSER CENTRWGAL CUBIC FEET PER MINUTE CEIL6* CONCRETE CCN3ECT1ON1. CONNECT CONT14J4TION DESIGNATION DOUN DRAIMG ELECTRICAL ELEVATION ENTERING EXTERNAL STATIC PRESSURE ENTER NG WATER TEMPERATURE FILL FLOOR ORAN FLOOR FLEXIBLE REL OIL SUPPLY KIEL OIL RETURN FEET PER MINUTE FEET PER SECOND FEET REL OIL RJEL OIL VENT RJEL OIL FILL FUEL OIL PIMP GAUGE GALLON GALVANIZED GALLONS PER MUTE HORIZONTAL HORSEPOWER HIOL RIS) HEATING VENTILATION( AIR CONDIT10N2'6 INSIDE DIAMETER RICHES OF WATFIR GAUD KROJ'ATT LEAWNS AIR TS'PERATURE LEAK SOS OR Maxi 431 t CM AN+CAL THOU ANr. BTU PER HOUR Pt 4I4JI MO NTED NEU NOR01ALLY CLOSED NORMALLY ^,: 'D1 NORSE CRITERIA NEMER OUTSIDE AR PIEE56LQcE DROP FIAMING PAS. Parr* PER SQUARE \NCH CGS) QUANTITY REQW.EDD EVOLUTION PER T 4JT= STATIC PFEE55LQ STEEL TYPICAL VENT VELOCITY IITI4 STEEL awcsF ILI4a4A "AY O 4 i 1 fattliaziefil N1001ECT 711 N F.•xw Rosa A.I.•pt•4. T•.as 760.2 011011E tltti 636 -5696. F AR 16171 636 !649 ENGINEER TIE NAY OOMII.TAIIn 14330 Mannar Ori.• Sot. 250 Coss. f•.•s 75234 roam cecpomMOR HIGHLAND A880CIATR8 228 East 4541 Street New Yak, NY qOV t2lZ b$1-0200 12ND 681 -0201 - fax nnwlielandassaciates can New Yak • NNew Jersey • Petrol's-aria K61 PtM AKA OF *MK • 4 3A5NG OEPT GOIRE\TS S:2i7 3 e9.120 FOR 7E a 2 65.E0 FOR PETE& 3 3 1 6S.E0 FOE. Ft1G 3 - :7 NO OESCFi:p � N ' c p k 1 i:;4. a 1 f; 1 1-4 . (13 xjA ii VG Qale: E' p SCE 1 5 Vr':J STET :t .i* SET M -7 • r mrmerimp- 3355 5 South 120th Place . Tukwila, WA 98168 FUEL SYSTEM, GEN NOTES,SYMBOLS AND ABBREVIATIONS 5 Ois7 r - . SER 4y - erE u \ -• - - ep4 RJ_L OIL PIP: ARCHITECTURAL LOUVER (BY MECHANICAL CONTRACTOR) MATCH EXI5T VG NSTALL4TION . MECHANICAL CONTRACTOR TO PROVIDE 50)05 ATTENUATOR GRAVITY 13ACKDRAFT DATER (TYPICAL FOR 3) 2• REL OIL vENT—/ PANG TO TERINATE ASOYE ROCF PARAPET (TIM& FOR 3) c i i 2• vENT STAR .4 DT -3 (2) r FOS CONIeGT GALVANIZED SHEETMETAL EXHAUST DUCT FROM FLEX CQ ECTOR ATV BACKDRAFT DAMPER TO ATTENUATOR. 0 O O O 0 DT - 1FTtM1 REFER TO FOR 5 $1131 _TAILS T -2 AT$ AT$ 9d BYPASS MECHANICAL CONTRACTOR TO Rl 4I5H AND INSTALL 5C tdD ATTEMIATOR INSTALLATION SHALL ALLOW FOR Tl-E REMOvAL OF 5011 D ATTEMMTOR BAFFLES FCR FUTURE EOLEPrE MT NSTALLATION 0 25f)C(Y A 126ALV I 1� Sv1Ta 0 L UPTO CE!LNG 0 REFER TO ARCHITECTUAL O 0 o D*I GS FCR hF0 (2)1kRJEL OIL SUPPLY ( lI R EL OIL RETUIRNI DOUBLE WALL PIPE 1 1 irSrAC -2 EXIST. MA•OLE 0 0 0 G 0 CONTINUED REFER TO ARC*4ITECTUAL DOIGS FOR MORE �Fo L FUEL OIL PIPING- PLAN s cA LE V s r `-U) MAW -10LE (2) l-kR2EL on_ SCPPLY(2) 1 -PRzl_ OIL L 0 O O ' . . - 0 --D O 0 . - O.'. O• -O- -. . - - .. O-. O 0 0 0 REFER TO DETA•L ON CRAM T1-09 FOR Ft,EL OIL PIPE CONFIGURATION CCNTA6rf IT FOR CIF tiT!LIDGR (COORDNATE WITH ALL TR4E>E5) 0 (2)411.M- 0i1 5U PLY(2) t -kRa.. O.1 Rc 11.2e4 -- : : - 0 • O O O O 0 i G 4 i;A•( 1 AROuTECT COMM IIONOAIL AICIU1IOT, AM 711 K F4'C4/ Baal A„ay10. 24.44 Nov AHOtE 18171 616 3656. FAX Iattl 676 seA UM /ANDY CONSULTANTS 14830 Yyq*al 06.41 sr. 250 O444 T4.44 75254 PROJECT COCO:WATOR HIGHLAND ASSOCIATES 228 East 45ds Street New Tat. NY DOD 12w 681-0200 (2121 681-0201 - faa NNwiigliandauoci2tesCOm New Yak • New jersey • PetnsyWaria KEY am AREA OF //OK a BA.AG OEn COtaE ;:s 3 SS.EO gar astr 2 6.S ED FOR �i7Ei ▪ •SS.EO FOR Fusty 143 CESCPvT INTERN/1P' 3355 South 120th place Tukwila, WA 98168 SEE 10 x 3v,rn INS MECHANICAL FUEL OIL PIPING PLAN M-8 5 C2.L7 4v! Cr 3.25 et 1 CIENERAL NOVE 1- 1 •.MALL L AUTOO4l1TC SIIIT•c2F Ary RISIBLE LNC FIRE RATED YALYIYG L ALL kV. OL PPlYi LONJ PONT NAVE SIITPS UTN LEAK RER 4SIED IAN TANG RUNG SYSTEM kV INSTALLED BY CANTRacTOR DETECTOR CONIR)1cr0R TO PROWL* RPNG 5T10P DUGS UM SU'P LOCATUOA$, 7. 3: 2' PRMARr MR UM CAP. MEND PPE E6FT ABOvE GRADE (TYPICAL,. r REL OL (OVERFLOW RETURN CGOTECTION UM 7. COORONATE ALL IIORC OM PRE-PU4SED OMB= Ovflii.Oli PPEY91TIO4 VALVE (TYPICAL/ GE PERATORra AND TANGS. 4. DOIUL£ RIPEST FOOT VALVE (TYPICAL/ 5 AN AR SPACE LEAK S13Lr10R WED TO DETECT REL OL LEAK (TYPICAL,. 3. DAY TANG 5WILL NAVE OL COOLER AW 6OE.9NOD YALYE rat FEUD IPSTALLATTON BY CQ(1RACTOR FOR MN GBERATOR b. FILL LIfTERrOvEFFLi PREVB(IIA( YALvE (5E1 AT 914 TANG CAPACRYa cO aRALTOR SHALL PROVIDE ALL NECESSARY carmen 1. LOR LEVEL AL4@1(RE ER TO SEQUENCE OF OPERATION FOR PERKS COALS./ NCLIDKs VALVES GAUGES. REX COFECTIO6 AOp FiTTNGS AS INDICATED: 5020( CR AMMO E 6$TDD AUTO FLL STATION TETER TO BOOR PLAN DM F0-2 FOR LQCATi011 S. TAVC GAGE TRAI81TTER CO RECTED TO rIOOITOR7N6 SYSTBI 4. ALL CONTROL ANC) POSER VRNG BULL BE 14 MGT) COO•E')16L N E600tt b LEAK DETECTION PROBE N TANG A:NALAR SPACE MED TO 5. POSER BRNO STALL BE N SEPARATE RIGO CO DIY. LEAK DETECTION SYSIBI N lECT'TMTCAL Row. 1 VENT TO EXTEND ABOVE ROOF PARAPET:TYPICAL) 6_ ALL REL OL PPID SHALL BE P1101 AT I/6' PER FOOT TOUR, MAN TANGS. O. SCO GALLON B'ERGEPCY GE#RATCR DAY TAW RIMMED BY GIBERATCR PIA NFAL7IRER L PEAT TRACE ALL REL OL Mira. IEATI E.B'ENIT BULL IL OL COOLER WISED IND (STALLED BY TIE B7EliGEIJGY GBERATGR BE DESIGN FOR IEAINER CLILITE Al 20V GR mow ' E4�IFAGTU R'QS INTEGRAL PART CF T1E MGM. ( TYPICAL) FOR 102 DESEL REL- IEAT1D ELEENTS SNWU. BE IA LEAS. COMM AND TRABBITTER CESPCtr® 50 TIER 01ATa f11 OUTRR DESIGN TT3>°ERAIIIiE DO NOT D GEED TIE RASA PONT OF TIE PRODUCT STORED B. Maio( CONECTICN NITTI DECK RV BALL VALVES AND OWED CAE? UTISV TIE SVELTE,`,.. T6. TUB. OL PERM PIPE WALL BE AT LEAST 2FT. BELOF7 TIE VENT PPE PITOED MAIO TPE ELAN TANG (TYPICAL/ ET. OUPLEX REL OL RIP PROVIDED BY GENERATOR N4VFACTINER J BPi OD) IFOS ---} `O"4) BY --�o� - INV (NO) 4 N°) t Etav r BYPASS — *5v : -'l.' FOR RCP 1105 1 1 1 1- cv Nizu SCALE N S ck. as DDwirc..`s VEST 1' RTE/ OL LC COMER LA I i 4 �� -- T i E I Rant et 11 o LE.IiEL ATA I 11 I OF_R•LOglii"PCtt 11 FLa P(ry OFF 1 1 Ra. I RIP ON x L LOCI LEVEL ALA4'1 U 1 I FV DT ! REL L COOLER A$Y �} -151–DS FO5 fri? Ave I I �,► f— I 1 1 r - =: 1 F M - Lj i � I L I I 1 4 i t 1 o : tT L_NEL r4: E : � 4-1 1 I 1 11 I QFp a+ II � I - F RT? O� 1 1 1 11 _ l II I he- pry62.4 1 1 1 I y LOC31� -1F RE : I 1 FY P1 Di I I' DT __11-=___ 1 REL RAP (TYP) — F05 - -- —� _ _ igeJ = I = , 1 N L s7"Y} OEN/ 3 DAY TAM( : :: 1 CO RECT TO 'C51 F.E. OL P°Ns> •.MGIE_ (NM 'SOLARO( VALVE (TYP) Ea Y ELL SOLESNOcc YALYE PC6'1AL FU. 50LDNOD YALvE BC) BY III- - (I) BYPASS VALV£ DOi W L P'dTfa dl 66Os DUAL (NO) 1746 I I IZHI>Q 1 E *PSY E?5v r BYPASS (VD) P.17`t1RT TANK E rBv..� CY VEST WCOh7.'.RY TANK S Y vAT r"Rf3S �' RET. OL SIPPLY RS_ CR. 04E LDS. COKIROIL R LEA( DETECTOR i GAMER PP` S.FFL.Y SWCASD 4E0 c& a4 s+ ..as,: A-53. L.7:6 CR AS'E 3:a S is ALL JOINS 5 4ALL 9E BAT iJE.FE, DaWn: - D CCRNIONS AT VALV$ P.t 'S AD DAY TAWS 2. Ca(CASING S 2e CASING ULL �E a TAWS. $93074 W . 9 REUX tacED ME ; l= ca a ENC* CASSia swLL EE 51"" _ TO co a T Net PPE NIT T4 &W:Ceir C4.EARA`C' FOR MEN / ELY st•D Ti4E2T4. Eifx.4‘904 CR C� 4TRA0 -Qo4 CF i t�E NEQ PPE_ • t LC r cmtet FOR* (TIP) itr r coOY Co4rjx'e -PP■6 LEAK GE-rvQ5 0)1 mama eV P.E. c : co VIL CARE: -- MAN va1vE PRESE0E RELEF VALI& OMELE POPPET FOOT VALVE (fl'O) - .'.• — P/ T 'DP Ttam (T P) le 1 'iM'. ? AT TIZ ET{ %TS. 5e. eC-Y'M FLEILITe 3.L Pf FOR t =' v`E -mot CR MEE cinc ia i o J.' • :: MILLS ME FOR REze oLY_ MOLOACAL COCRA CR TO ARNiEwi AC 1.67 ALL 5CODJA cog-Limo P E. of P. 76 IC TAE E 311E ! C$!)fs NSTALLATOt F ` CFEY Ti34AN.A i 1 '.r! ,"i 4 ! ri PFraiiioi; OACHTECT. COS1LAIO YOMAN, ANCIENT, AAA Itt N i.•pr R5$ ArtPSts•. T•sas 160g own( item 636 - -5696. FAX lave 636 5699 PO MO 1A PROJECT COORDINATOR HIGHLAND ASSOCIATES 1A fast 45(b Saw New Yak, NY TODD (2W 661-0200 11TTJ 661 -0201 - fax v.wwlia iandassotiates<an New Yolk • New Jersey • Pea sylvaria 1 SULDNIG CEi; COMIEV5 3 sum KR oEasr • 65-E7 vies t SSED FOR R6f. .7.(5.w usTERNAp- 3355 South 120th Place Tukwila, WA 98168 9e tra 9637 oG Tit TOM CONSULTANTS ties! vo't'ot. Ocn• s. . 730 Owes. pas 75791 E, CP as MECHANICAL FUEL OIL DIAGRAM AND NOTES M -9 1 77: 374 3 -:. 1 r 1 • ": • ! - 17.!! 1 i• : : d • • 1 i .... .. 1 11 1 r ••...., - ',II I .../.... . 6. .. 74. 1 r --. r• — .... 4 1 1 :: t - i - • i ...• DOUBLE WALL TANKS (TW.) - • • • - • ...:41 , . i-.• .!" --•• -.....1'.•' - ..tr . •i••re;. -- -f ' _ ::- o s'•57 -.: z•.v.: - •-..; . 'i".1.:' • - 2,: . 11 : ,.: . . . __ ' - -'•1 ::., '-':- •••:- :. C ■••T: :. . 4- - : - . - ; - .1: - = "ay.4 • .•.: -- -:- _ eI t_ir.ei v- a ar...1 c _40: 7 , ...:'," ....it:•_ :F 4. 7.... - • :i'...:71..._ c .. / . " :. ;".... - :2. .e ..... . ...: -:-...:.. -.'..... ., --: , ',. * z"' " • ---• — _TYR _ 1NTERSTTL SENSOR DETAIL • ( : 1 1 P! '4:17.3tIMPO •-•Inz : ) ... 1 trr. rETA:s : 7417 DETAILED VIE L ZEE •." .1 IR ir . .":•Ert - - 1 IT • lj • VCR rhIAILEC VIVA OF 1 DETR:L : TRES 53F.:1! & Ci f • _CM _ - • -1 ; • •••- rYP. FUEL/OIL TANK ASSEMBLY DETAIL .- • Tvo .. - :NS i eitt • c"..rlf) s : • . s: t_r • •-• • L. . . . . . . F•.IR :TLI") ViSii Cl.F..11i1117; :314. ' Ann 1471T ::1w IL 4 TRTS ;71:r: 1 " :s.e.t a.- :t. L. 4 7* FL 7 7...1611 • • . • .--LP 4 E • • , • rays". v P•F; 7-e:41.1 2:: ' . a 3 .re. ;tat.- I • 31t f..C73: •C4.7 . 5 _ 7 zISEq_ NIEN• ; STENTA SEk: tut. ra!: FUEL oil 'SYSTEM. SCPEDULE 1 ! • : . .1.:•■•• ••••••••••■•... • ..; istiP. PROBE RiSEH alAIL s" z - - *L3' • • •- - - - • i7 • - 1, : . -••• • %6S 12 : „ Of4)14(e : : t - de : • • * . • 7.Z . _— ___ . _ _ . _ . _ __ . __ _ . _ . s• 7:7:. c .. ;_ :': . . : • ..e. Z. • V ! E.:. E..i.4 -. 5 :.P • 1 .N•••- 6€.4 . . Z. : • i • • ....• • • C 3. ' i.a:Ve. •Ii Z7: l':: • : 7... ,...--:,..7 er. . aw_ ?v.:1' z I . 7 4 , ; : • . '‘.. :•-•....$ 2t „..... .. • 1 . ; • ..... 1 a, I L. : a • 7.- .;:- •a; 33i-25 :-.N.ce.• C!TT .: • - :. :1%7 f.. C17-:..7.7P ' 735. 0 3 t - - T :i 2 VW." Cr.15, •e r-. :•:P___: 3..; Ls 3, ' S. 91CLE : r - 4. • ..... Ns; • -- ' r > cl.' ! y ..... . a •• - ••••• 'el 0 7 - - -: • -A-, k-4-_-z • - s1stvre• ? 1" '.e•e.' , T-T . : c -fitt.:' 1 - - 1 • F . F-.•...1;c . 1 7-7 :•7 1 •;^: 1 1,7 : ..trzr• • t .1 ..,....,,, _ _.. 7r....-!..:: :. .: ' - -• 13- - .- - - :.d.o : :" V••:-" Ir .- Iv: E i ;TA.- ! :5- :z C:0_•:''.. • No; a • -IP. it,,-.11., . • £l•• 1 7:' -:411_: :1.1c:'.1.. :F.: • :S-: - ... . st.':. ;Jug : iC.-•..c.z•CF ' :4 ( ... • ■ iii : v.. . , - 1 % ...i. I: . .1. - Zg f -:, . :.) ..s : - :••- ....- . ;I :.: . ., .:- • 1 - .7. AM'S . 7 ; esi zc t . 3 .. ..... _.:- _ V !•U•....4, .._ I ...A•Iii I ..01e _,,),JF. ef..4 a. ZS Z.:'-f. , '.'. ti 3 e. ::-.- if i 7 4 . ..zSit .11, 7. iT ) 5 - cAs.11. ..41:.p....is • r .• V.: - ...- -. 4. 1. _I -- S,.14" ' %CC?: S.:7 _ :•:.• C-" ic-•• Feji_ .a':. -3•! us : '94 1.'. ..t ;7:- 1 •:': 1 71 AW e...114 t -: 1 7'4 ; . :I% S. IIF . .i .3 1 -Esc Zr_cr:z: ..._ ::% 1 k •:.-• ' ...g. C•-. : a. .AVa S...A1C- 1 i "I s‘r. 1 ', I at. F...t.f i...a g -f 1 :- 43-z-Z3s' '..: - Z-- 4 4:-• t E.".7-- REVIEi i: c�€ COMPLIANCE . APPROVED - CRY Ct 2 , 7, -... ‘_: . - - RECENECI CROFT:3MA rAY PFKolliCZATZA comma NOMA% AMINIIII0T, A111 11t iv cows Read Moped. Toe 1140.2 pow* ism 636.5696. FA a 63646ve Ancsviftl. EFIGNI0 TIM POW CONSULTANT1 no 0. 11.11 79151 PROJECT COORDITAPOR HIGHLAND A880CIATE8 228 fast 45th Sates New Yak, NY 10017 MB 681-0200 681-0201 - fax wwwhigNandassociatescom New Yak • New letteY • a40.X.CT O 3355 South 120th Place Tukwia, WA 98168 MECHANICAL FUEL OR DETAILS SHEET I OF 2 M-10 Pennsgvaria li 1-1 110 �Q . ! ja , 1 • § 11 . f§A l=r0 i 5 • MN* CO A Cr • . • •• • • aa . 4 . • • .4. •.'". • ?N .. 1 • . ; ••1 .. • I; J 1 I • , / • • ' " • • ••■•••••••• :.• • 4 • • • .1 f I.: 1 • 1 i * ..rt. ' 4 Li ' : 11 • 1 I r • • ...-,.......1.1_ 1 • • ,-...... 4- - ••••--: --:-I'ir..,..••,, •,,•,.. ..,„,,... 4. ••••■ .. ••1 I... 4'4 . 4; .• 4 ••• 4 • - - 1 • . • ... :.... ...:........ ..:,..... it................. M•1■••••■•••■•■•• 1 • • :4 :4 99•■•■•■ 9.99•999 • 9 •I • 1• ' • 4. ...4F.: .4.•••••••••• • • ••••■•, 44. ; 1 A, • : f • ••-• 1 • 4 ...1.c1. • , • I • . • 're •• ...■.■•••••••••••••■• • - •••••• • :•• • .•. •• • e... 1 - . 1 t.....1 ' 1 •.1 1 ! i: i t 1 : ,.,.1 ! : ., 4 t 1 ! , : II f l : . 4 19 i .1 '• .4 I i 1 ;.• - .1 t •• 11 . I ' % 1 1 9 • 9 • 1 1 9 4 ' I el . .: •• 1 1 S 1 : ; I .. . t I 1 : . • . • • 1 : :. i . ..... 1 1 ' 4 1 1 1 . .• '' ! ; 4 1 . ' ...: • i ; 1 1 I . • 4. 4- ••••• •11 ■,---•"•'•" • .. -.--. -•• -•.... . 0,.......1 : . ,...... 4 ' I . . .41 1 . 1 i t; :1 i • , : ' 1 ; . . . 1 ! • i 1 . . 1 • I I . ....... • 1 I ‘....-. 9/ ....... =: . ,; . .. !:""' • I ••■•••■•■•••,•• I 4 , • • • -J 0 • • •••4. • I 4' • 4. •• I •• 0 0- U.1 0. / / i ' / 4 1 ................ / I V ....=...) ' J 4. .., I : i • 4, . • .. • I 1 • • •• ' • • • '470 41'.. 1 ' 0' • .• • • • .••• ••••• • • .• „ 4. . • .; .... -Is / .• A: . •44 , i 4. k • , t ,........, • .• - ...11• 1, • • . • •., .• .4 .. ......-......_ •..... ilim..•.,,t • • ... • • •• • • : N • 4! ..4 0 .0111 s. , . ...1 •••• • ' •• 1 r . v ' •• 411; •/ • • • • \ ••••__• • •••• • .•••••••••••••••I•••••••••••140 / 1 •••••10 .. raw. ... v. 44• .4 • y.I.j.voic 1 • 14.• • .1 • • • • •••• t . ....., . • 1 t !. 1 •• • • ••• • • . • • .44 • • • , , • • •• • • • • • ••• .0.• • • .6 . 4 opl ••••1:1141, • .41 • 1 1 11 .4 71. :". • •'I I ■ Tif 9•••••■• • • r414.014•••• l • :• 44 • • •• • 4•••••••••• ... ••••••• ••• ce • I •••• • • • 40.•••••••••••■••••••••••• „ • .4 . 1 de • . 0 1 44.* I • e•• • 1. ••• ?t 1 . . J... ON•••••• ••••••••••••••••I1M •••••••••••••••• vl■I• a.■•••••••••••••• •••• 1•••• .•••••••••••••••• •- • ••••1 r ,....■•••■••0•1•1110•■■••••■••• L •••••••••••••••••■■•••••••••• . 44 , . It' !, 4. , • .8 • • z . ••••■••■•••••■••••••••••ma. • • 1 7 • ■J I . • .......••••••••••••• 11, . •• 49 • • 9 • ..•••4 •. 1=.0 1 ••••••••••■•••■••••■ m••••■••••••••1/111, •••••■•■• • 1 171 ,/ LJ 1 • 1/ • • • , • .• • • • ••••• ••••••■•••••■••■•■• • •••■•,•**. r; 0. 0 . 0. It' • • • e 4. IP a 1 A Rchalw 4� 11 � t - .91$44eu .11 W b( t%a. N w . Q " Lon a 0 0 d }W W e I tft 411 11111 ▪ u • '- Of 11 Q � J A a. 4 Q w W • a I a -4 - a 9 4 • aaaaa Idttit §.§M MEE 0OCAA i4 14 r e V V A aM Oggg 666 - ffff O AAAAA ggggg • IiNNNNN 4 a W O J Hi , , J 1' _ "�A�d� .1 0 Wig" lo W:iigt 1- 1 4P ' p g4 ,w vid al i� r ,.:Qwzi y QQ A" do o mm001mA s aaaaaa 00000, .A00•110,,, 40$01W4 5 5 .Q W * L1ttlLltbniu1 InIthfIhiML1Nllt1 111 3 ligi t4 W 44 IS1 244;; Ng - 1 4 11~ 4 1 a 1g 4 u I 42= 104 4 oop 46 u 48I_) - y r ~� •'1 4 Er2 0 a • t . t (- -142 9 _ p � a up, 4 � da'. } h mat {�I � 1 �� 11 a i zal Q tia � a W 'I. 0 U 0 0 V 0 _.1 iv r, N 111 (1) 6`'b 4 , 19 40'n +1� .1 11 �y l y lo � q e g :141° 1• . • � 1 11 9 ;111(11; 111 t ) !1 n 11 6 t 1 W Iii II iv ot •, 1 '1 oN •1 (3 �' • I.1 1 � 1, , )- tl in l u > 1 � 7." 01 to:� i • -' 111 "' 111 I+ ., q , � " 8• ' 1 ! 1 1 . !y n . 1n 1 d) a 11 l t •n , ] 1 ,11 ,, 1 1 1 n1 1YN )WW111 IYiY YiYw N•p1114)14)(1iQl • 411 1ri Ih 'I • r .., 'tli 1 4 ( 11.01 ll ut 1 1 1 11 5 a • }} +1� W . 1. o 1. � 1 (1 11 ; W.1YWy� �) WI I• ` ,» 1 .1 .1 ., •, ) i 111, :1 X 1 1 ' A Q' ). 111111 III . ). 111 Ill , !) , 1,�' in in 1 -r I. 1 t ( �' � � t 1 1 1 1 80'laaaair 3�)1I► ;ywO�t % 1 I. 1- 1 • 1 1 1 1 1 1 I. 1 1 . 1 1 • ) • IWIYWIYIYWWIYWWIYWW O f' CV 1 1) 111 y '• Ok •r °' G t �• '� F�l(� ' I / " • 1 11 l i f T. ' , .Vii, ON �► l-U r',111 ,.' 1111 iiii �! : j Y � ; iiiii 'i6. ti' , • � 1. :eip4.1: I I , rigl � '101-111 t 1 v1 SyVV..., 1 1 1 10.1 bop ,) 9 J t1 1. ++ d i it' 6�-I E i Q• 1" •..• t?'..11. 1+ " �, Yl� 1`, � 111 >. I 9 ;A11 '• •�) III l 1(1'1 � 1� () RIu a 1 !'l :y 1 N 1 1.1 • d A9 ! " ;1 1 •I W w i; (1 ;1 g 6 111 01 .•1111 0 1n 11 u , .1 S ' } I;� 1:104 ; 1 �► In VI „ .11, Q i 1 G? el .1 U + t 111 ' P 'aa•, Illll' ,+� 1) 8 ,1 u, 11 • r) Q;1111 . ;•� 1 ! �; ) i i1r3i IL) , t , 1 , I I , II)lyVW lYIi+lyWWW 4 11)0 et Q m C= W wta c) 1 • • 1 :� . • 0 as S I i _NER (CO.T Nu :5a 1J-E� SF ECF - D='� CL;. LF.°LY CLCT SEAL= CQ: sA.STG eard DCC� LAS-. O SEA SUco. SE4E'• 01 TCP OF CL 26 CsA F= x' =Ys 2x b� CANT- -w ET rC E. °Q:.v E =X AL WA.. OR Q7r - -A+'= tip SEALER G1FQ ALL SEL`rs -A° 40N EX. TO .ILEA --M FANS -•I AND �O�G'.►: \4: HANGER STRAP SEC -RE TO STFLICTLRE AS RECTO LOCATE WITHIN 2 FT. CF DIFFUSER CEtTERL:% FLEX DUCT. $EE PLAN FOR SIZE PROVIDE TH RADIUS CON`CTICK PROPERLY SUPPORT FLEX DUCT FOR 51" IOOTH AIR FLOW TO DIFFUSE PROVIDE 2 ANGLE CLIPS a4 OPPOSITE SIDES OF DIFFUSER SCREW TO T -BAQ SECURE DUCT TO FLANC 118TH DMA D AND 51- EEIMT4L 5C. DAR CAN S\ SC:FPCR:T ANTE FA CE CF G-Q.'LLE CR Dt2 RO �D C..0 Sax er NOE CEILING DIFFUSER CONNECTION $ca'e. N CCAC E ROOF/ • • T DIFFUSER/GRILLE MOUNTING s NCI` 34 GA!s:�V_ A'S 5O- 1:0.2 ALL .•O \TS. s q Se�A� r •E : t r CLEAR.- L: E R \O DUCT SELLL' C-rP1 /..;Csu LEVEi .3 EDOFNG • N. ,ZAT ON Bi.LT P ROOFYs . T S - QA∎ AEZE'3D ..'O SrPL T. _ GS FOR ROOF FENETRt O+a__: I • ING :ALL C.1C"3.NG TC BE 1' RETA - :a.' 3 ALL CXX:F PENE ATOMS WQl.?4E areia.L:R s+-.-',.4 5EE- caw._ 0.8"63 SHARP RADIUS NOT ACCETABLE DUCT I5x DtArE:TER LAY -L'l T -BAR GERNG D3FUSER PANT CUv IDE CF D $ER CAM lil1TH BLACK PANT 1L2NiG . / FR H 1G SxET !ROCK C=_ILN6 STOR'1 CO_LAR :_LT!D L.6 54 751T'X SEo G- R(LLEIDi?.:SER WITH Sri SC4ZEW5 T1- RROtiCi4 NECK CF GRILLE CR ID +'S P E I RA { ION '- QOP DETAIL r - N.SLt G BOA. AP 4 4F :FLY DUCT SEALER me-Svc EEFose suaxCs cz_iF 0■To DL CT 6 FLly -. SEAL 'EYr.:+EYs GLs.ss GL COvEZED Lis COLT &i. OF SEALER O 26 G.1. P_A9 "ICs SOLDERED :Ca+? sic LEVEL G. 1 2• £P G`.. CANT ROCF Sl-EET ET3L =\SL+ HIED CT,a _Aim D:sC H ANGER STRAP SUPPORTS P ER SMACNA ELECTRICAL REHEAT COIL (AS REOIARED)- DUCT TRANS, AIR FLOW RAND DUC 4' -0' MK CF LINED DUCT i REI•EAT COIL CONTROL BOX NOTE: PROVIDE SEISMIC BRAC6Ya AT ALL VAV BOXES. SEE SPECIFIGATICNS FOR SEISMIC DESIGN CRITERIA. PROVIDE 2 AMLE CLIPS ON OPPOSITE SOES CF D^i15E'Q SCREU TO T -BA. VAV TEE MINAL BOX SUPPORT Scaler N_ SLEPENDED G ILACs CEILING DIFFUSER CONNECTION (5Q NECK) 5eatek .Ct` SLEEv= r12' L;.I .Ft rdb\ P.PE. fA 50-: A0 P:� F + X WALL OR La: PACK . i:-% ROCK - CQitcee...I -L 1 ESG:TG E Oti 80-- ST }_s • • r olCYl �s►a -L TA DVERCR PPE �iON- as :J �iXG- : :=R PRDCIF WAL.'..NT I H DArVER ACWUATOF VAY BOX L NIGN PRESSINE FLEX DUCT. 3 FEET MAXR'1H. 6•IINIrG-HCAN �— ON SQUAW D35ER VLL.L E' r-zca PPE N.L.: N TO :;a1F �K moo" - ' :.Pe Rrt771G PIPE LEE DE T AiL Scs's E SHEET METAL SCREW STRAP TO BOX. SEAL AIRTIGHT (TYP) LAY -Pl T -BAR GE Di5ER ALL : rat EQ•1LS N :'FIST :zL.e. i..\ t F ;E;— R .T' RATING ASSW E CLEAR DOOR SWING PROVIDE TRAP al EACH REFRIGERANT LesE Ul/ TOP OF TRAP AT HIGNEST POINT OF CONDENSER COIL 1I1 1 1 1 Illlj REFRIGERANT LI'E PITCH PRODUCT BY GC. OR PIPE CURB BY MC. REFER TO PLANS - ROCF DECK TRAP REFRIGERANT PIPING AIR CONDITIONING UPS /BATTERY ROOM DETAIL 5ca1s N10' MAV.FACt . R . cii.A 1ST FAN ROOF 1 ACA) *Max%ORB ;11111111111[111 jt4 c4�'4 (e 1 111 11 11 11 1 TYPICAL 5ca • a Vii: UTILITY CURB rv&. sr CUSTOM OURS NC. OR APPOVEO EQUAL. ATTACH AND FLASH TO RIOCF AS PER ROCFOiG MANIFACTURER - 5 RECCtIE •DATtGNS. PROVIDE LEVELLNG AS RECD =RED. EF -I ECCNOM:2ER•5rr.OIC EXHAUST FAQ SEE MAN FOR LOCATION:5 I r MONT CONITROL DA:PM + 0= 1:'DCF ORS. PROP Z. AC TO ACTUATOR !ROCF 1 NSTALL CRA N P.PE UTH TRAP N LEST PONT CF DIiiGTd rm< AND ROUT. TO AE.& ST FLOOR DRAIN 111111111 1 1 ,........ I,... I.... fk gaixoccin e g \ ; '.•'- i EXAUG T FAN DETAIL T T� _ \ Anoint! CORTLAND mown AIcNTIOT. AIA In N F.Wf• Road • Arlr.9tc I. T•••• 160.? PROVE 16111 6365616. FAM ISM 636 San ENGt4ER WET ID TIM NWT CONSULTANTS I4650 MaHlat (3r..• Sa -• 250 Des *. Tens 7525a PRO.ECT GOOt10etAtOR HIGHLAND ASSOCIATES 221 Eau 45th Street New Yrek. NY 10017 12121 681-0200 12123 681-0201 - fax wswwlligNandassociateuom New Yak • New jersey • PernsTlvarra t 9ACC•GCEPT amen 3 6S.F3 Wawa 1 GSM FOR EYE+ 1 WAD Flit FIX YJ MSCPt :p % 1JYirmeAP• 3355 South 120th Place Tukwila, WA 98168 CAVE IsVs: scat* sC"e 98r :r f MECHANICAL DETAILS SHEET 1 OF 4 M -13 1 PIPE SIZE (Rd) MAX SUPPORT SPAN (FT) i MN_ ROD SIZE (N) UP TO 1' 7 3/8 I -112 9 3/8 2 TO 2 -L92` 10 3/8 3' 12 112 3 -1I2 13 1/2 4 14 5/8 3 !a 5i8 6 11 3/4 a 19 118 I 10 22 1/8 12 23 1/8 24 GA GALV SM SLEEPER FLASHING "PRE-FAB' PIPE SUPPORT t CLAMP (IF APPLICABLE) FACTORY' CURB ROGF�Ks� NOTE: I. PROVIDE CRICKET a4 UP SLOPE SIDE 11.114=N SLEEPERS ARE PERPENDICULAR TO ROOF SLOPE. FOAM GASKET ON TC1s OF CUB 6t5TALL CONTROL D INSIDE ROOF GIARES. PROV1I E ACCESS M CURB FOR DA ACTUAT 6X4 F ■rTA.WAMT CONTRACTOR CTCR 1445 OPTION TO USE STEEL 2� E L i EF EXRAUS T FAN DETAIL 04 TOP CF Ci.RB -- - G%LY C RES CEP. SEE .:RCr FOR CET =L 2X •1 Z SMTLR7A. \T 5TE _ °SEL`: =L5T 1 71 • _J Scale. NOTE: WE ARCM. ENV STRICT. DUGS FOR ROOF PEN.— TRAT1CN. R_AS1 -ING- E ROOFS Cs r ET.".'LS- 0 0 0 0 0 0 0 L Ei.'RGtLAR BARS PiC SITE N ROCP ROOF PIPE St1PPY�RT : . "dam 3.)Q:A1,L4Q e.zas 2 \7 FLOOR 507 OF ROOF D CCC 1 'I BEND BACK METAL SILL PLATE TO FLOOR 1 48' 36'1 DIA. • DUCT /51• -IAFT TERMINATION DETAIL Scale: NONE GYPBOARD SUPPLY AIR SHAFT WALL. TER{" HATE GYPBOARD 2' BELOW RAISED FLOOR \-30' HIGH RAISED FLOOR EMEND METAL STUDS TO CONCRETE FLOOR SEE ARCH. DWG'S FCR DETAILS ,.RETE FLOOR SHEETMETAL CONE (AIR DIVERTER) FASTEN COLE TO CONCRETE FLOOR CENTER COKE TO SUPPLY DUCT 6x FIRE RETARDANT WOOD SLEEPER MOtNTED ON TOP OF ROOF. - 5/8•INISTRUT 1r2'x 4 LAG SCREW. PROVIDE NEOPRENE -STEEL WASI RS BETIUEEN CAP 1 STRUT ROOF PIPING SUPPORT DETAIL Scale: NICKS 1 CANT. $=E A r Q - J� cS4 DIG'S FOR DETAILS E. i 7CF , BUILT-UP ROCcNG D1:GT 6'x6`x16 GAGE STEEL STEEL PLATE rL$T1 i `-'.5 :"G TO CENT 1 CR X E LER. D AG 5 s DET42.15 RASING. .' D':G"5 FOR CETL L$ NT. SEE D:+G'S 1-R DE7Z.1.5 •. 5WI :, 0.4 CS.2.E7TeATCNS s a ;;sue :. 5E L�r = a� .R•� D.6•5 ;0R FL•.iG. AND C..JF3 }•41.5 :n , 61 - =- T AT ems- C;i.R5 DETAIL Sets .AE XHAUST FAN FASTEN FLASHa16 TO CANT CR NAILER SEE ARCH. DIG'S FCR DETAILS /It— FLA.5:12`G. SEE ARCH DIGS FCR DETAILS OFLISED DISCONNECT 24 NV- IA 3R CABI ET. FIELD MOUNTED ON FAN OR RACK SEE ELECT. DUGS. ` C.C1N TE .ROCP L 5/8' BOLT WITH LOCKWASHER AND DOLESLE MJT } f 1 FASTEN DUCT TO METAL. STUD FRAMING. SEAL ALL .:02,T5 SUPPLY DUCT BRANCH TO VAV 80)e5, SEE PLAN FOR 51 Z WALL 1.0.5. " SUPPLY DUCT CONNECTION TO SHAFT Scars •got= I i I 1 1 1! :r 48' CONICAL FITT81G S DEWALL EX+ -44US T FAN i TC ijN iN 5c.‘• F FRAM 4ROtUIV AT DUCT COl4ECTIO14 G-YPBOA.RD SUF -FLY AIR S14AFT WALL SEAL OPSVNGS LEAT- c SE: L2.IT 5E. LPL D G'S. F :5T'l C.EArl -ERFO ID D4`?xQ WARD. ESECKD 4FT DE: PER. AND CALL CA »LQ TO L.••LL. SEEL CO .ECT O i:ELT+c Ys�T .,EAT• -ER OiOD (f.5 W-CID) D2. FEQ DL"PE.Q GLUM" Ci. c -4NGL .S StFS� 3 ' F4N CCNOWIE. ddsLL 1 FLASH DUCT WALL DUCT PENETRATION THRU WALL Scars: NONE PIPE 1- IAAIG-ER DETAIL seas. rOM- MO LLELD CR 5OLT - A E TO SIDE CF EQUIP. c B AND CR DUCT EXTERIOR WAL NON HARDENING SILICON SEALER (TYP) 16 GA. URx1- 11!x1/2 CHANNEL FASTEN 16•OC. STRUT FIFE CLAP 3/ 6• T'Y°:C L I: ELDT"',l —;71sT DFA E8 COLD RIOLLE STEM_ 9ASS..".FiD' AT E4Cr: ilitilititif i Uiii 1 1 1 1 DUCT LINER 14ANGEii ROD M. 1/2• DIA. ;yr,r.E•RRLA' e.A.R 3.ELD 2005 TO ,4• ATTACH TO STRICTURE WITH STRUT ACCEbSc1 S AS RECIt1IQ=D (TYP) TI -"RMAL 14.4NCs` SHIELD CR ISOLATOR STRUT CHANNEL SE =SP:1C RESTRA'NTS PER 6 4.4 G'JIDELNES e j SECURITY BAS ASSE••BL 5ra s , OBE NOTE: AO '-=5 a .LLQ SLR~ a4S Y 'O ALL RC e" C EVNGs. �Z 5Q r. N 6LE FRA M OPENING AS NECESSARY 1 t REVIEW 104 E CODE COMR L�'VC AP N .4• ! " 5 -.. I c ,Cif 1tZ .- CITY C 4 ; t Lvi 1 ARCHTECI C0111LAND T AIA Ili N f*ba RosO Ai.rgroa. To■as 160'1 FMGME ism 6)6 -S696. FAR IWVI 636 "564T• EN.PEER PROJECT COOrDnitOR HIGHLAND ASSOCIATES 223 East 4Sth Street New Y. NY 10017 (212) 681-0200 12121 681 -0201 - fax www}indas6ociales.tun New Yak • New Jersey • Pennsylvania Tit !UM COINIILTAIITS ..aso rarAtear a•.. Sues 2S0 Oaras. T.•as T525a a BALM 061 CCAr1E•25 3 'SS:EO f02 � 1.T 2 RA =ma s ss.E0 Ka cur"; YJ JE$,pFEflt PROJECT 3355 South 120th place Tukwila, WA 98168 O 5 SC4; 9 E< T MECHANICAL DETAILS SHEET 3 OF 4 9 M -14 1