Loading...
HomeMy WebLinkAboutPermit M04-142 - SEATTLE'S FAVORITE GOURMET COOKIESSEATTLE'S FAVORITE GOURMET COOKES 935 -939 INDUSTRY DR M04 -142 Parcel No.: Address: Suite No: City oi Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us 2523049034 935 INDUSTRY DR TUKW MECHANICAL PERMIT Tenant: Name: SEATTLE'S FAVORITE GOURMET COOKIES Address: 935/939 INDUSTRY DR, TUKWILA WA Owner: Name: CALWEST INDUSTRIAL PROP Address: C/O DEL0ITTE & TOUCHE LLP, 2235 FARADAY AVE #0 Contact Person: Name: PETER CRELLEY Address: P.O. BOX 33370, SEATTLE, WA Contractor: Name: PRO STAFF MECHANICAL INC Address: PO BOX 33370, SEATTLE WA Contractor License No: PROSTMI072NG Value of Mechanical: $9,790.00 Type of Fire Protection: N/A Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended /Wall /Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 2 Air Handling Unit <10,000 CFM 0 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial /Industrial 0 doc: IMC- Permit * *continued on next page ** Permit Number: Issue Date: Permit Expires On: EQUIPMENT TYPE AND QUANTITY Expiration Date :06 /30/2006 DESCRIPTION OF WORK: REPLACING TWO (2) EXISTING A/C UNITS WITH NEW A/C UNITS (ONE 3 -TON AND ONE 5 -TON) - "LIKE FOR LIKE" CHANGE OUT Phone: Phone: 206 361 -0071 Phone: 206 - 361 -0071 Steven M. Mullet, Mayor Steve Lancaster, Director M04 -142 09/03/2004 03/02/2005 Fees Collected: $269.58 International Mechanical Code Edition: 2003 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP/ 1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood /Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 M04 -142 Printed: 09 -03 -2004 . City oY Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Date: 9 ( 7 /" Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M04 -142 Issue Date: 09/03/2004 Permit Expires On: 03/02/2005 Date: / Print Name: TO WI tut=s) D This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Signature: doc: IMC- Permit M04 -142 Printed: 09 -03 -2004 n City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS Parcel No.: 2523049034 Permit Number: M04 -142 Address: 935 INDUSTRY DR TUKW Status: ISSUED Suite No: Applied Date: 07/29/2004 Tenant: SEATTLE'S FAVORITE GOURMET COOKIES Issue Date: 09/03/2004 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Readily accessible access to roof mounted equipment is required. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248 - 6630). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Conditions * *continued on next page ** M04 -142 Printed: 09 -03 -2004 a. l . I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Print Name: tM Signature: doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Date: 9 r `° y M04 -142 Printed: 09 -03 -2004 King Co Assessor's Tax No.: G S3 o4 c 0 q Site Address: 9'35/9"'N a l PU 2.' Pftl VIE Suite Number: 9 3 5 Floor: 1 Tenant Name: sf.•A i TL.t�'5 FM/otz►rr coustMEr s0o fcs s New Tenant: ❑ .... Yes p4..No R(- 1= Property Owners Name: Mailing Address: PC- T1.,Z Ct`r_ Ll. -1/4/ Mailing Address: ?. 0_ 13c 33370 Name: State Zip E -Mail Address: org.,52.- a pit o - f 7r C-H hN) cti_. , Go m Fax Number: Z o L - 3 ,(- 04 24- Vig 1; �W ',2 ' l :? . Y7• ::t :..II',.G444S .?s�:ztc, ,r4i; Corn s - y Name: Mailing A . • ess: Contact Person: E -Mail Address: Contractor Registration Number: * *An original or notarized copy of curren BAR w ..rt3c2fr;{ 01 I Contact Person: E -Mail Address: Company Name: Mailing Address: NG EI ::OF YRECORD: ='AI an mas hie, 'et sta „yv__ itiped liyEiig ineer;ofecor .w -. �= �':+� . `:a ,�.�•..r ' :y ''�'" •}Ji " %uCT.nr • t . v, S .i^,;.' xs•, .4. '.� . ,. �(2. i Y ��1h• 'Y �P•..vFV+�...Y?:. -e + +1 ._.?'�::.,.:.a.•;.F.. ; ,'S,,_,ltiY � r +3 .? � b ,'.'; w YzJe•. . S , +•a - f l E! .2��� . uJ� - rx tk 1 y.S• S'' %{'.. •. ' 4 r..':3 :. '. E: �.- ..... .. ... Contact Person: E -Mail Address/ Company Name: Mailing Address: 1apptiationslpennit application (1 -2003) 1/2003 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** (31 Si >z i4Nr'r,Z• REC - Dr it plainV mu 5 e wet stampe Page 1 13L ✓p E.4 City ashington State Contractor License d ". cgitect o City I Rec l urwt WA 9 (a/es State Zip Day Telephone: 2 2' / —o 071 sf AY1 LJ l✓4 /t3 /?"3 City city Day Telephone: Fax Number: Expirat' Date: Sta State Zip t be presented at the time of permit issuance ** Zip D • Telephone: Fax Num tam', t t {1kti t..�'•�'':.t':C?�' a k • rtFz' ti: r` 9�_'. City Day Telephone: Fax Number: State Zip tl s' ♦.•::1:i}'.''. '�.L;:n ..b. ..w.1.L.Si1I..ayw..,:. S li.'w . Y... rw.:i.Ji• .ut BUILbIN s GE R f T INFORMATION X0 64431 36 #Y,yya� a '+ y,# r,1 "'i t ` .1.. �.t..) • fF'tC .l7N „kl" 3�1 w + rr �) WsJ :"-;Ye ttfli'•MZ'' ?:?`,'; :W.: ''' �i :'C�': s�, ,'>i,`.: .`j'. *�tL + ;� } -'.':. x ° Y•ir,. ^ ° tY�. ��2._ 1 .. .. rW�"',,,� „,t r.1 Valuation of Project (contractor's bid price): $ Existing Building Valuation: $ Scope of Work (please provide detailed information): Will there be new rack storage? 0... Yes 0 .. No If "yes ", see Handout No. for requirements. Provide All Building Areas tn' Square :Footage Below-- Floor 3` °,.Ftoi ral asemerit ccessory'.Structure, * Attached:Gatage. :,Detached'Garage: ;'Attached;Car Detached;Cat Covered'DecN Uncovere : Addition to. Structu }: PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑...Yes ❑ .. No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0.. Sprinklers ❑...Automatic Fire Alarm ❑...None ❑ .. Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes ❑...No If "yes", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets. UTILITY DISTRICTS: Note: If the utility district is not City of Tukwila, you must provide written verification and approval from that utility district at the time of permit application. Water 0.. City of Tukwila Water District 0.. Water District # 125 0... Hightine Water District ❑... City of Renton Water District Sewer 0 .. City of Tukwila Sewer District [] .. Val Vue Sewer District ❑...City of Renton Sewer District ❑...City of Seattle Sewer District 0.. Septic System (If property is served by a septic system, 2 copies of approved septic design from King County Health Department must be submitted at the time of permit application) \applications\permit application (1.2003) 1/2003 ct W UO too: COW WO Q, !Q . Z ' 1-'O Z Lit O N: 0 I— W U' LL in Z U� O i ; V131LYC, Z1IiK54 E T-; .,ORY1%tA4TtiCS ry 71 y t i'�1 tiOV�ti�7 *4. �,,� P1 " FF fA cr:rk^�;Ik7. e:xi. 1 q� . yr93 S�rkt• m3�: j'r, c .., (( s, s _ 'YA'a':33!.'3�AI:inS ����: /Y,:�lL k7�LG'Y.*v��yJ`(.ykw.'��u ^ ".�I��•n}7 5��;�. ��. ��rt": f;hYj'�. 6'��" Street Use: ❑ .. Street Use Land Altering and/or Hauling: ❑ .. Land Altering: ❑...Cut Storm Drainage: ❑ .. Storm Drainage ❑...Flood Control Zone Sewer Information: ❑ .. City of Tukwila Sewer District ❑ .:Sanitary Side Sewer Water Information: ❑ .. City of Tukwila Water District ❑ .. Water Main Extension ❑ .. Water Meter/Exempt: Monthly Service Billing to: Name: Mailing Address: Water ... Water Meter Refund/Billing: Name: Mailing Address: \applicationa\pennit application (1 -2003) • ❑... Channelization/Stri ping. cubic yards ❑.. Val Vue Sewer District 0.. Sewer Main Extension ❑ .. Water District #125 0.. Private Sewer ... ❑ Call before you Dig: 1- 800 -424 -5555 ❑..: Curb cut/Access/Sidewalk 0... Highline Water District City Sewage Treatment City Scope of Work (please provide detailed information): lease iefei.ta PUNIC Works Bulletin ' #l; for feesand estimate shee ❑...Fill cubic yards ❑ .. Hauling 0... Public Size(s): ❑ .. Deduct ❑ ...Water Only ❑.:.City of Renton Sewer District ❑ ..City of Seattle Sewer District ❑ ..Private 0.. Public ❑...City of Renton Water District ❑ .. Water Meter Permanent #: Size(s): ❑ .. Water Meter Temporary #: Size(s): ❑ Fire Loop/Hydrant (main to vault) #: Size(s): ❑ .. Miscellaneous: 0.. Est. Quantity: gallons ❑ .. Landscaping Irrigation Day Telephone: State ❑ Fire Line .... ❑ State Zip Day Telephone: Zip Unit Type Qty.' Nit it Type ,: - 7 ::,Qty . ; Unit Type .Q•y, _ ; Boiler /Compressor :Qty, Furnace <100K BTU Air Handling Unit >= I0,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System 30 -50 HP /1,750,000 BTU Appliance Vent Hood 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System Incinerator - Domestic Air Handling Unit <= 10,000 CFM 2- Incinerator — Comm/Ind 11/E IAMCA yy l��s j . P E y RMIT:INIKORMATIUN; _ x':`206:= 431 = X3670` �� :,, YAV,!}I•- P 1:. •.�' la• u J. is i, 'S \`n :.,��� .n,+i,an1:�`' Kati;? �' s:; f:: �#'. s�RS,: afrnat. �' �.'' rz�it�.; �', ���'', r�`'.',:.. t..,'; ��::' A.; `���'t,JS��` ^�?�,�,yr..,�c.t'rF i +�",};�r.T;, MECHANICAL CONTRACTOR INFORMATION Company Name: ¶ 7 i c o — 4 / 1 - r - Th r � T � f - > i • A-/1 ) - 1 L . Mailing Address: 7 0_ 3 cy< 3 - 7 0 S % Ail — La Lt/A 96/ 74 3 City Stale Zip Contact Person: 7 1 r l 4 2 . tit = L L is y Day Telephone: 2D & - 34./ - D o 7 1 E -Mail Address: 'POT a y: o.-- STAFF Mr:ed -m-X, e-A -•t, _C ...014A Fax Number: 7-O L -3 6/- Olt 2- Contractor Registration Number: Piz 0,TJ1 ..072 / - 9- G� Expiration Date: 479c, 0 * *An original or notarized copy of current Washington State Contractor License must be presented at the time of issuance ** Valuation of Project (contractor's bid price): $ 1�1 P L ✓o r K /�, i 1 N- AC► l'N ,TS W, Neu,/ 4c UN ITS ( - 3 Tot-) /-NV o 5 - i�N) "L/..4 — Fog — CHAN CIE -O �T Scope of Work (please provide detailed information): Use: Residential: New .... ❑ Replacement .... Commercial: New .... ❑ Replacement .:.TX Fuel Type: Electric , Gas .... , Other: Indicate type of mechanical work being installed and the quantity below: RE AP.PLT Ar�I RCS e: �q all p : it it nts :appucati ' o ri �ta +�'�:•?� «A'; ,�.!' t* �iv:3:;�' :;t ".'?„• 3r.�'Y �'xt t... �'. � _ ��4._se•�'!; Ft�",YF uy.:5:. s .�9i��t 4 ;,;�, �'��•�: S.'. ^� %:':,. Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is s'Lbject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AU 0 IZED AGENT: Signature: Print Name: . / A. rot / -o Mailing Address: '1 v 3o 33370 Date Application Accepted: — .� 7.--r � \appliationslpermit application (1 -2003) 1/2003 Air 7q �f/�T'12tr 'i4 Date Application Expires: ?- Page 4 City State Date: 7/7-7/ Day Telephone: 2.O L— 3 4 1— t7 0 7/ Staff Initials: S Zip ....gin f: t.+. isiil7�seii :J.saz><::a..:u:rnuw:;a'.�:ai r_..• u'�a.G;�i•G; ,;.: .. r • �tiww.,.:. r. c; c, �i.:+ w: n«: r+ i; r.. .w:�a:.r..: <w.,:t:,::+:.�:L:.'li �� '.. ' Payee: PRO -STAFF MECHANICAL INC. doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 RECEIPT Parcel No.: 2523049034 Permit Number: M04 -142 Address: 935 INDUSTRY DR TUKW Status: PENDING Suite No: Applied Date: 07/29/2004 Applicant: SEATTLE'S FAVORITE GOURMET COOKIES Issue Date: Receipt No.: R04 -00970 Payment Amount: 269.58 Initials: SKS Payment Date: 07/29/2004 03:05 PM User ID: 1165 Balance: $0.00 TRANSACTION LIST: Type Method Description Amount Payment Check 8237 269.58 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES Account Code Current Pmts 000/322.100 221.66 000/345.830 47.92 Total: 269.58 .; -32132 07/30 9716 TOTAL 269.58 Printed: 07 -29 -2004 E P ject: 6 I p /� ` U Type o Inspection: Hr \ i ress 'n . l C o o ll./ -. af Called: C l ( i 1J Spec Instructions: �,J. Date Wanted: 3 / �� a.m. p.m. Re 4 Y e IA mill D P hone No: ll (� (i cA '4 �' ,,,,; �. -�: », +may •� INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT . CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)433 -3670 a pproved per applicable codes. COMMENTS: O 1L— — it) - i`I■Ts- t Inspec auto Date J 3 ) 05 - ri 5 .00 REINSPECTION FEE R • UIRED. Prior/to inspection, fee must be p • d at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. 'Receipt No.: I Date: Corrections required prior to approval. »'*'' COMMENTS: / / f 1 0 — 2/.0 r 5 SCft,i , r I .S fr1 ? r' El'X IS -/ .:v 5 d Zee: ,e%• /e-a7'/ / .A. A¢�r e e ss : g /0 i /., / F ti") / - A4 .e 0 vp-6J $ Nd - r" i, ". / c hove I 40 &vr' A n /A 7 /N /75 . /VC' .5c 4/% A (2 d) / / /F-7 Gt/ /a / AI 6 / cif /N /7-S -i ,et r, Av6 l NI= cDJ in /5V...,,, A . / -L- /t £t . i0 -7 A 1 ---- r oe ?II ✓-r Project: �I �. S kilo rite C'7 o m�1' C Type of Inspect k yes � p / (t�. [ A¢�r e e ss : Date Called: / sc Special Instructions: Date Wanted : / 6 ( os _ a.in. (f Requester: Ph a No: 14) 3 _ ,? D 14 tie INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION Approved per applicable codes. nsp. or: INSPECTION RECORD Retain a copy with permit 0 q - 1tfa 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Corrections required prior to approval. Date: 11 eul u / /o �b S 58.00 REINSPECT! N FEE REQUIRiD: Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. 'Receipt No.: 'Date: Aoje \Qq I p � S.15P- 'l pIrme4 • Type of Inspe ion: "C' - Ad r s� , Date Called: a , % c? Sp • cial Instructions: Date Wanted: . // O /93'-- D3 p .m. Requester: N� Pho No: �0,0(4) 4..)2 - 3o 'c Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ❑ Corrections required prior to approval. COMMENTS: tor: / Gw�+-0 1 1Date: 2- t / 0 OS $ ' .00 REINSPECTION FBE REQUIRED. Prio to inspection, fee must be �i at 6300 Southcenter Blvd., Suite 100. ll to sechedule reinspection. Receipt No.: 7Date: cc W' V 0c), cow cow rn W 0 } ' g J u.Q co W . O ; uj • U0 1- WW 111 Z co O� Z File: M04 -0142 35mm drawing T' (. r OF 7 I KW lI a JUL 2 9 2004 P ERMIT cEN 93 5 T- N19 v •5 V1 q pR,vt. 13L pc, . 29 A c -1 f J� L- Z r Q L-A-r em wi rail -r" UPI r f Packaged Gas/Electnc Rooftop Units _ :::i'i'r ..:.i .. .'r'tlry „ < °ai iti'_t.. •ti .:.iT:Jd °.' ,`.i! „... . "f''.`s5-'. , q:::.�s; 'ii °fi'; :+�f'1:4i. PrecedentTM 3- 10Tons -60 Hz PILE COPY Permit No CODE COMPLIANCE APPROVED SEP 012004 Of Tukwila BUILDING DIVISION }'�.'c »• .,Z.:J r:dCti >:' .. '! S• °; ?.'i "lWib :•1q— f; •-• a.,rt :, ?.ti..'•ti d3:i i; Pk'.i,i' May 2003 RT- PRC006 -EN General Data (3 itTort,u) St iro tird Efficimicy r" Cooling Performance', Gross Cooling Capacity • SEER Nominal CFM /ARI Rated CFM 1,20 ARl Net Cooling Capacity , 3 System Power (KW) Heating Performance' Heating Models Low Heating Input (Btu) 60,000 . Heating Output (Btu) 47,000 6 AFUE % • 80 Steady State Efficiency 1 %) 80 No. Burners 2 No. Stages 1 Gas Supply Line Pressure Natural (minimum /maximum) .4.5 LP (minimum /maximum) 10. Gas Connection Pipe Size (In.) 1/2 • 1/ Compressor No./Type . 1 /Climatuff Her Outdoor Sound Rating (dB)" Outdoor Coll -Type L . Tube Size (in.) OD Face Area (sq ft) Rows/FPI Indoor Coil -Type Tube Size (in.) • Face Area (sq ft) Rows/FPI Refrigerant Control Sh Drain Connection No./Size (in.) , .1 Outdoor Fan -Type Pr No. Used/Diameter (in.) • DriveType/No, Speeds •Di CFM. . No. Motors/HP Mofor RPM Direct Drive Indoor Fan -Type • No. Used/Diameter (in.) DriveType/No. Speeds . •• Dire No. Motors j • • Motor HP (Standard/Oversized) 0.33/ Motor RPM (Standard/Oversized) 950/1 •• Motor Frame Size (Standard/Oversized) :. 4: ,400 0.5 1/1,200 000 91 Bum High 000 120,000 000 95,000 0 80 0 80 3 1 14.0 14.0 1/2 37,400 50,300 10.7 10.1 1,200/1,200 1,600/1,600 36,000 48,000 3.79 5.28 Viedium High Low Mediur 80,000 20,000 60,000 80,0 64,000 46,000 47,000 6 81 81 BO 81 81 80 2 3 2 1 1 1 1 1 4.0/14.0 10.0/14.0 1/2 . 1/2 1/2 1 4.5/14.0 4.5/ 10.0/14.0 10 1/2 1/2 1/2 .1/2 etic 1 /Climatuff I lermetic 1 /Climatuff Scroll • 3. ced 125 .19 17 nced .3125 5.67 2/16 it Orifice NPT peller /22 ct/1 50 20 5 83 86 Lanced Lanced 0.3125 . 0.3126 7.19 6.17 2/17 2/17 Lanced Lan 0.3125 . 0.3 5.67 ' 6. • 2/16. • . 3/ Short Orifice Short 113/4 NPT 1/3/4 N Propeller Propeller 1/22 1/22 . 1/ Direct( Direct/1. Direc 2,550: 2,850 3,610 1 /0.20 1/0.33 . 1/03 1,075 1,075 1,07 M r e 8r 1 FC Ce 1/10 trifugal 10 t l2 ' .50 100' 8' FC Centrifugal 1/10x10' Direct/2 033/0.50 930/1,100 .. 48/48 80 80 00 r.d 5 8 6 itice FC Centrifugal 1/11x11 Direct/2 1 0.60/0.80 1,000/1,100 48/48 , 1 /Climatuff Scroll 82 Lanced '0.3125 9.59 1/17 FC Cen 1/ ifugal x11 rectrl 1 0.60/0.80 1,000/1,100 . 48/48 1hble GD - 1 = General Data 12 YS Ac- 3 -Ton Convertible Units 36A1 , YSCO36A3, A4, AW 4 -Ton edtibie Units YSC048A1 High 120,000 95,000 80 80 YSC048A3, A4, AW 49,200 10.0 1,600/1,600 47,000 5.40 Low Medium High 60,000 00,000 120,000 48,000 64,000 96,000 81 81 81 01 • 81 81 2 3 1 1 4.0 14.0 1/2 1/2 Lanced .3125 6.17 3/16 Short Orifice 1/3/4 NPT • eller RT-PRCO06 -EN 1,) • Pri • N y • y • "- • • , Table GD-i — Continued RT-PRCOOB-EN General Data Belt Drive Indoor Fan -Typo FC Centrifubal No. Used/Diameter (in.) 1/11 x 11 DriveType/No. Speeds Set tNariable Sheave No, Motors 1 1 Motor HP (StandarcUOversIzed) 1.00/— 4 1.0 Motor RPM (Standard/Oversized). 1,750/— 1,75 /— Motor Frame Size (Standard/Oversized) 56/— 5 — Filters -Type Furnished I° Thro away Throwaway Thro away Thro away (No.) Size Recommended 1212 x 25 x 1 (2)20 x 25 x 1 (2) 20 5 x 1 (2) 2clx 25 x1 Refrigerant Charge (Lbs of ii-22) 7 .8 3,8 4.4 13 YS 3-Ton Convertible Units ' 36A1 YSCO36A3, A4, AW . NOTES: . , . • • • 1: Cooling Performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb, Gross capacity does not include the effect al fan motor heat. ARI capacity is net and . • •" includes the effect of fan motor heat. Units are suitable for operation lo ±20% al nominal cfm. Units are certified In accordance with the Unitary Air-Conditioner Equipment codification • : • .: program, which is based on ARI Standard 210/240 except AK (380V/60 Hz). • . - , • 2. EER and/or SEER are rated at ARI conditions and in accordance with DOE lest procedures. • . , ' . • ' - 3. Integrated Part toad Value Is rated In accordance with AOl Standard 210/240 or 360. Units'are rated at 80° F ambient, 80° F entering dry bulb, and 67° F entering wet bulb at ARI rated • elm. • ... . , . 4. Heating Perlormance tidal settings and rating data were established and approved under laboratory lest conditions using ArnirIcen National Standards Institute standards. • Ratings shown are fOr elevations up to 2000 reel. For elevations above 2000 feet, ratings shotild be reduced at the rate 01 4% for each 1000 feet above sea level. 5. 'AFUE is rated iri accordance with DOE test procedures. . . . . " 6. I Outdoor Sound Rang shown is tested In accordance with ARI Standard 270, For additional Information refer to Table P0.85. 7. 'Refrigerant charge Is an approximate value. For a more precise value, see unit nameplate and service InstrucliOns. . .. • ' 8. 20 x 25 (Me on medium and low heat models. 20 x 30 titter on high heat mortals .9. Motor RPM shown Is low speed. High speed RPM Is 1,080/1,145. • . . . . • i •10.0ptIonal 2" pleated fillers also available; • • • , . • . (3 - 4Tortiu) Standard Effncy 4-Ton Convertible Units YSC 8A1 YSC048A3, A , AW • • „ • • . , • ". • ,• , • co • 10 . Ot: g:M; '12 mi. • a • -t I=! Table GD -2 — General Data Cooling Performance' •Compressor • No./Type,'. Outdoor Sound Rating (dB)° Outdoor Cola -Type Tube Size (In.) OD Face Area (sq ft) RoWs/FPI • 14 YS 60A1 Gross Cooling Capacity 6 100 • SEER/EDP 9.• V— Nornlnel CFM /Aril Rated CFM 2,000 ,000 • ' ARI Net Codling Caliablty ' .60,110 Integrated Part LoadValue — System Power (KW) • Heating Performance° . fleeting Models • Low Mac urn High' Heating Input (Btu) 60,000 • 80, 00 130,000 • • Heating Output (Btu) 47,000 ' 63 00 103,000 AF DEW . 81 : :1 80 Steady State Efficiency ( %) 81 : 60 . •." No. Burners 2 • 2 3 Nd. Stages" • 1 , 1 1 Gas Supply Line Pressure Natural (minimum /maxirnurn) 4. /14.0 LP (minimum/maximum) 10 714.0 Gas Connection Pipe Slie (in.) 1/2 1/2 1/2 1 /Clam • Iu8 Scroll Indoor Cell - Type. • Lan :ern Tube Size (in.). 0.3 5 Face Area (sq fl) 5. Bi wa/FPI 3/ Refrigeraht Control. Short t rifles Drain Connection No./Size (in.) 1/14 PT Outdoor Fan -Type Prop Ilex ' No: Used /Diarneter (in.) 1/.' DriveType&No. Speeds . Dire :1/1 CFM 3, No. Motors/HP 1/1 33 Motor RPM .. _ . 1 • 5 • Direct Drive Indoor Fan -Type FC Cei trifugal • • No Used/Diameter (in.) 1 ' 1/11 x 11" ' DriveType/No. Speeds • Dir:ct/2 No: Motors . . 1 . Motor"HP(Standard/Oversized) 0.'r /1.00 Motor RPM (Standard/Oversized) 985 1,080' Motor Frame Size ( Standard/Oversized) , ''4.48_ ' (5 -•6 " on General Data Stooldorci EffiiCiORICV 5.1on Convertible YSC060A3, A4, AW, AK La iced ' Lanced 0. 125 0.3125 8.r1 13.81 2/ 7 ' 2/17 V (s 6 -Ton Co edible YSC072A3, 4, AW, AK 03,100 72 00 10.20/— —/ .2" 2,000/2,000 2,400 ,100 60,000 69, 0 0.78 LI w - Medium" 60, 00 80,000 48, 00 64,000 81 81 i 81 1 84 Hit h 130, )00 104, )00 8 ) 13) 6.7" Low Mediu 80,000 120,00 64,800 97,20( 81.' 81 81 81 2 1 3 1 :3 4.5/14.11 4.5/1 0 • 10.0/14.0 10.0/1 .0 1/2 1/2 1/2 112 1/2 3/4 1 1/Clirnatuff r atuff Scoll 1 /Climatu f Scroll l Lanced 0.3125 5.00 3/16 Short Orifice 1/3n NPT Propeller 1/22 Diroct/1 3,470 1/0.33' 1,075 FC Centrifugal 1/11 x 11" Direct /2 • 1 0.90/1.00 985/1,080" 48/48 Lan ed 0.3 25 1 8() 217 La iced 0 1125 .89 16 Sho t Orifice 1/ NPT Pr peller 1/26 rect/1 ,100 1 .70 1'75 A N N/ N/A N/A N/A N/A High 150,000 121,500 81 81 3 2 RFPRC006 -EN 0 01 faa to W W 0 . W W!. U y! i0 —k .� Ht W W" .Z1 e 0 • t- Table GD -2 -= Continued Belt Drive Indoor Fan -Type No. UsedlDlameter (In.) DriveType/No. Speeds No. Motors Motor HP (Standard /Oversized) Motor RPM (Standard /Oversized) Motor Frame Size (Standard /Oversized) General Data 5 -Ton Convertihle lac TRANE' w 6 Ton n) Standard lEf ficie icy 6 -Ton C nverlihle ' YSC 60A1 YSC060A3, A4, AW, AK YSC072A , A4, AW, AK FC Centrifugal FC C Atrif 1/1lx11 1/1 x12 BeltNariable Sheave BeltNaria le Sheave .1 1.00/— 1.00 00 1,760/ — 1,750/ ,750 48/—' 56 ' Filters - Type Furnished!'' • Titre " way Throwaway Throw ay (No.) Size Recommended (2120 i 5 x 1 (2) 20 x 25 1 (4)16x x 2 Refritetrant Charts (Lbs of R -221 4 . "4.9 7.1 • NOTES: .. ' • I. Cooling Performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet hulk. Gross capacity door not Include the effect of tan motor heat. ARI capacity is net and includes the eltect of Ian Motor heat. Unite are suitable for operation to 120% of nominal cim. Units are certified In accordance with the Unitary Air-Conditioner Equipment certification program, which is based do ARI Standard 210 /240 except AK (380V/ 60 Hz) units. ' 2. EER and /or SEER are rater) at ARI conditions and In accordance with DOE lest procedures. 3. Integrated Part Load Value Is rater) In accordance with ARI Standard 2111 /2.10 or 380. Unite are rated 0100°F ambient, 80° F entering dry bulb, and 67° F entering wet bulb at ARI rater) cim. 4. Healing Performance limit settings end raling data were established and approved under laboratory testconditions using Arnerlean t lational Standards institute standards. • Ratings stiovyn are for elevations up to 200(1 feet. For elevations above 2000 feel, ratings should be reduced at the rate of 4% for each 1000 feel above sea level, '5. AFUEIs rated in accordence with DOE lest procedures. • 6. Outdoor Sound Rating shown is tested in accordance with ARI Standard 270. For additional information refer to Tabta PD -85. 7: Refrigerant cliarpe Is an approximate value: For a more practise value, see unit nameplate and service Instruclions. ' .. 8. YSCO60A1,3,4,W Oversized Motor and YSC060AK Standard Motor Fan Diameter Is 12 x 1 I. ' • 9. Motor RPM shown Is low speed. High speed RPM Is 1 100/1135. • , 10. Filter size shown Is for low and medium heat modals. High heat model tiller size recommended is 20 x 30 x I, 11. Optional 2" pleated tillers alsoavaitable. • 12.YSC072A when used to a horizontal application has a EER M 10.1 and System Power (kW) of 0.83. '13. Medium heal, Is hot available for AK (380V/ 60 '1z) Lnils. . 14.Outdoor motor Is 0.75 hp for AK (380V /60 Hz) units. 15. Outdoor motor Is 0.40 hp for AK (38011/60 Hz) units. . 16. Standard Motor Is 1.00 hp for YSC060AK (3110V/ 6011z) units. 17. Standard Motor Is 2.00 hp for the YSCO72AK (360V/ 601 -Iz) units. 15 1 All dimensions are in inches /millimeters. 3, 4, and 5 Ton Standard Efficiency — Low and Medium Heat 3 and4Ton High Efficiency — Low and Medium Heat 3, 4, and 5 Ton Standard Efficiency —High f leaf 3 and 4Ton High Efficiency 7 1ligh heat . . 1 ""i. STon High Efficiency —, Low, Medium, and High Heat RTPRC006•EN EVAPORATOR SECTION ACCESS PANEL ALTERNATE CONDENSATE DRAIN CONNECTION 3/4 14 IIPT CIA. HOLE EVAPORATOR SECTION -` ACCESS PANEL \\ ALTERNATE CONDENSATE DRAIN COtINECTIOH 314.14 tIPT DIA.11O/.E Dimensional Data V 41/4' 10B MM 4 1/4' 108 MM 23 0 /I6' 50t1 MM \ fifl 7/8 42 1/4' 1749 MM 1073 MM I/O NPT GAS CONNECTION .238116' \ ,� 606 MIA ,.` 697/8 ,42;:';,, 1740 MM 112 NP( GAS CONNECTION - .55/8' 143 MM 244 1 AM - CONTROL ME) COMPRESSOR ACCESS PANEL . _ 8516• 244 MM 5 5/8' 143 MM,r - CONTROL AND COMPRESSOR •: ACCESS PANEL 41 W3rVV t TOP PANEL 4 /4' 5 9/15' / MM 7 5/8' ,/ - 104 MM 44 1/4' 1124 MM '1 `. 59/16' X141 MM 7 5/8' f - 194 MM 44 I /4' 1124 MM e TIRANE° CONDENSER FAN 32 1/4' 819 MM Y ` '''' - CONDENSER COIL UNIT CONTROL WIRE 7/8' (22MM) CIA.1101 SERVICE GAUGE PORT ACCESS 1 3'8' (35MM) CIA.1101 E 1• \_ UNIT POWER WIRE 1 3/32' (26MIA) DIA. HOLE CONDENSER FAN 38 1/4' 921 MM CONDENSER COIL. UNIT CONTROL WIRE 7/8' (22MM) CIA.IIOLE SERVICE GAUGE PORT ACCESS 13/8' (35MM) OIA. (IDLE \_ UNIT POWER WIRE 1 3/32' (28MM) CIA. 110LE B1 a' I. • TRANS` All dimensions are in inches. 3 - Tons __,Horizontal Airflow Supply and ' Return x .i44 —1 3 -STons -- DownflowAhflow Supply and Return; Through the Base Utilities 3 -5Tons Unit Clearance and Roof Opening . 82 iy1♦orrL„"rrr...� Dimensional Data —nom _ 0114 �,,.._ 10 1/V _...- 20WAlA '935MM awMM surrty 4071.111 741 COIIDETIt ATE n([ 1 n11E 711111111011 °"°� 7 ELE 0 7�AL • \0 g M IAM) \\ r - ,(getut, , CLEARANCE 37 (940 MM) • CLEARANCE 48' (1218 MM) 010 4+% 1)41 -f � 3/4 375 MM ' 3/4 NP P CONOEI (SATE GRAIN 4 TYPICAL ROOF OPENING WV 510 311/ a 11151.10A RETURN RETURN 81MM 23 J4' 591MM /4 314• ' (1MM • 3 1/4' 'C- 337MM 171/6' , � 87 /o `'' •"":- 438MM " '225MM CLEARANCE h WNFF fAL 3/V FLOW 814 MM) 457 MM) .›.-' , „J J . �' 41 117• (1130 MM) \' /' CLEARANCE 313' (814 MM) • RTPR0006 -EN • TRANS' Tabie ED -I - Unit Widng - Standard Efficiency Standard Indoor Fan Motor Oversize Indoor Fan Motor Optional Belt Drive Indoor Fan Motor Minimum Maximum Fuse Minimum Maximum Fuse Minimum Maximum Fuse Circuit Size Or Maximum Circuit Size Or Maximum Circuit Size or Maximum Ampacity Circuit Breaker' Ampacity Circuit Breaker' Ampacity Circuit Breaker' Unit Tons Model No. C YSCO36A1 N 3 - YSCO36A3 YSCO38A4 YSCO36AW YSC048A1 YSC048A3 YSC048A4 YSC048AW YSC060A1 A-G -2 - YSC060A3 5 YSC060A4 8111111*, YSC060AW YSCO6OAK YSC072A3 B YSC072A4 YSC072AW YSC072AK YSC090A3 YSC090A4 YSC090AW 7'�i YSCO9OAK YSC092A3 YSC092A4 YSC092AW YSC102A3 81/2 . YSC102A4 YSC102AW YSC102AK YSC120A3 10 YSC120A4 YSC120AW YSC120AK NOTES: 1. HACR breaker per NEC. Nlndlcates both standard and high efficiency airflow. 74 Unit Operating Voltage Range 187 -253 187 -253 414 -506 517-633 187 -253 187 -253 414-506 517 -633 187 -253 187 -253 414 -506 517 -633 342 -418 187 -253 414 -506 517 -633 342 -418 187 -263 414 -506 517.833 342 -418 187 -253 414-506 517-633 187 -253 414-506 517-633 342 -418 187 -253 414-506 517-633 342-418 Electrical Data (Standard Efficiency) .9 20.7 40 - - 9 <gt) 20.3 30 20.6 30 2 10.4 15 10.6 15 7.7 15 8.3 15 8.3 15 34.0 50 36.1 50 - - 23,9 35 26.0 40 25.3 35 12.8 20 14.4 20 13.6 20 9.8 15 10.6 15 10.0 15 4 7. �B� 49.0 60 - - (�5fy 33.6 50 30.3 45 0 25 16.3 25 15.6 25 12.2 15 12.8 20 11.8 15 19.6 . 30 - - - - 32.7 60 34.0 50 - 17.6 25 18.2 25 - 12.8 20 13.6 20 - 23,2 35 - - - 42.7 60 45.8 60 - 22.6 35 24.1 35 - 17.6 25 18.8 25 - 28.9 40 ' 29.9 45 - 38.9 50 42.0 50 - 20.5 25 22.0 26 - 15.5 20 16.7 20 - 45.1 60 48.2 60 - 24.0 30 25.5 35 19.5 25 20.7 25 - 29.6 40 31.1 40 - 52,6 60 56.6 60 - 26.9 35 28.9 35 - 21.8 25 23.5 30 - 32.8 40 35.6 45 - RT-PRC006 -EN w Table W1 — Maximum UnitAnd Cotner Weights (Lbs)And Center Of Gravity Dimensions (M,) Unit Tons Model No. 11/A� YSCO36A - G -1 (9 ' YHCO36A 589 672 YSC048A 597 505 YHC048A 631 539 YSC060A 614 22 YHC060A 666 574 YSC072A 878 735 YHC072A 916 772 [,of4 J _ too #' " 7 BA-g. u TEAL '44 = X13 i' . 7' /e . 8t/ 10 YSC090A YSC092A YHC092A YSC102A YHC102A YSC120A YHC120A NOTE: I. Corner weights are given for Inlormalion only. 2. Weigltls are approximate. � C. -Z= 5 - 14/-t = .5 7_ ZL # 7 e..014 - • SA-e- o YDTAL. = 55t RTPRC0o6•EN Weights Maximum Weights (Lbs)' Shipping 963 965 1066 1042 1100 1130 • 1203 t CENTER OF GRAVITY WIOTu 1 Nat A 80 151 158. 820 822 923 899 957 • 987 1060 159. 166 169 179 249 249 273 277 306 297 310 325 342 • CENTER OF GRAVITY 1 -4 LENGTH ---6 A Dom. CENTER OF GRAVITY: • Corner Weights its (Lbs)t B C 124 128 ' 130 133 134 140 193 198 208 222 243 243 252 265 277 96 ' 101 108 114 105 119 132 141 146 147 165 165 175 183 197 Table W — Factory installed Accessory Economizer D 109 110 109 126 114 136 161 184 193 175 210 194 220 213 245 Options Nqt Weights (LGs)'•z elf NetWelght 6- 10Tons 36 10 • 80 30 26 .115 6 7 3 -STnns Barometric Relief Powered Exhaust Motorized Wilde Air Damper, . Manual OutskIe Damper . Roof Curb Oversized Motor Belt Drive Motor • Smoke Detector, Reurrn Smoke Detector, Supply Coil Guards .1-tinged Doors Powered Convenience Outlet Through the Base Electrical Through the Base Gas Unit Mounted Circuit Breaker i Unit Mounted Disconnect Novar Control De)iumidiflcation (plot Gas Rahpat) Coil NOTES: 1,Waights for options not listed are c 5 lbs. 2.Net vyeighl should he added to urjil weight when ordering factoryInslallod accessories, , 20' 16 70 5 31 7 6 " 12 10 38 8 6 5 ' 5 8 16 8 C TRANE• Center of Gravity (In.) Length Width 32 19 32 19 33 19 32 20 32 18 32 20 39 21 39 22 38 40 39 40 40 40 40 5 20 12 39 13 6 5 5 8 .25 22 21 22 21 22 21 22 Q9 • ExJ5T1N•G V14 1 r x3 e M.C P � p+. iNfeIll$�}till. fAdt.!'141iMAfitll0111it FTtN�'{FtJ?IJ1ffifflt tfii+ hG ?rY i ti i9 i?t <!IfttSfttt rT r�tW? ttflYri92lt+ Tr.Y�i�`pr3 ?flUfeiJl?i ;llbritf" #4iV .F,IL:4 � a;!i!, ;4g�r1 /Ii SINGLE PACKAGE AIR CONDITIONER AND CHAL-051r4fia. ,HORIZONTAL AND DOWN...F1 -O *37,000 to 42,000 Btuh Total Cooling Capacity 24,000 to 112,500 Btuh Optional Electric Heat "ARI Certified Ratings BASIC UNIT OPTIONAL ROOF Single package concept and optional roof mounting frame are Lennox exclusive features and give Lennox rooftop equipment a big edge over competition both in appearance and installation procedures. Primarily designed for installation on a rooftop with the optional RT8 duct enclosure or RD8 POWER SAVER"; it can also be installed on a slab at grade level with end handling of conditioned air. The single package unit contains all refrigeration components (evaporator and condenser units) air movers, air filters, and optional-electrical heat in one complete package. The optional RT8 or RD8 duct Applications Rooftop Installation with Optional POWER SAVER NOTE — Specifications, ratings and dimensions subject to change without notice. OPTIONAL ADS POWER SAVER v i " r l ln : c: �f �}�,''a ;: A ' MOUNTING FRAME � j+ l• t V - CHA8.410 & 460 ,, ,, I r t t f- � ��cl,� T.M (With optional POWER SAVER •, electric a • heat and roof mounting frame) Installation Flexibility Featured in Single Package Air Conditioning Unit Optional Roof Mounting Frame Detail Weatherproof frame (RMF3 -46) is used whenever RT8 duct enclosure or RD8 POWER SAVER T • M • Is used. The frame extends around the entire perimeter of the CHAS and RT8 or RDB. Duct connection and entry into the conditioned area are accomplished within the confines of the frame. enclosure and RMF3 mounting frame easily adapt to the CHAS unit. The mounting frame mates to the bottom of the CHAS and duct enclosure and when flashed into the roof permits weatherproof duct connection and entry to the conditioned area. No additional roof curbing or flashing is required. Optional POWER SAVER and controls (RD8) reduce cooling costs and satisfy any local code fresh air requirements. Externally mounted optional minimum fresh air damper (manual) is also available. A choice of 208V and 230V single phase or 208V thru 480V three phase models is available. Unit on slab at grade level ENGINE I DATA tri'M COOL�'` i�Ni NITS PAC ' ED 14r Febrtl y 1970 Supers X 117 -15.69 Z 1 t co O N0 . r1)W co LL to 0 LL Q co 3 uJ F. P; H - Oi W ~ • D 0 'O co 0 I— IwW Z 0 Ed H =; O ~ Z. PECIFIC Refrigerant IR -22) charge Condenser Net face area (sq ft) Tube diem. (in.) & No. of rows Net weight of basic unit (lbs.) (1 -Pkg.) Optional Combination Ceiling Supply And Return Step Down Diffuser Optional Combination Ceiling Supply And Return Flush Diffuser Optional Duct Enclosure (Without Power Sayer) Optional Duct Enclosure with Power Saver & Controls Installed FD -41 — lbs. " " "FD -41 -D —"30 lbs FD -65 —*I'lbs. " " "F D -65 -D —"33 lbs. FD -65 —"26 lbs. " " "FD -65 -D —"33 lbs. 1200 1350 1500 1200 1360 1500 1200 1350 1500 1400 1575 1750 1400 1575 1760 1400 1575 1760 Outdoor Air Temperature Entering Condenser (F) Airi C -� • b Cx1l vN,T 1301 # i' i�iCa `� 1 iTV:it�4�t'fiti v9i� ;'t��rli t' tlf. �. �4' lei�rYF? t' wq,! 54'+ litlt tl,•"+ Vlt:: tri• t.' li.' �E, e.: l.. 1 ".,•i'.i�:`!i`.ii•Ym!` ±T4 <i'c: OPTIONAL RD8 POWER SAVER BASIC UNIT i °f, ENGINEE DATA )f1r SINGLE PACKAGE AIR CONDITIONER COOL•IN ; UNiTS AND CHA8 PIORIZONTA4 AND .DOWN !$ 49,000 to 59,000 Btuh Total Cooling Capacity 21,000 to 112,500 Btuh Optional Electric Heat *AR! Certified Ratings CHA8. 651.653 (With optional POWER SAVERT•M•,electric heat and roof mounting frame) Down -flo (Extended duct distribution system) RT8 or RD8 required Installation Flexibility Featured in Single package concept and optional roof, mounting frame are Lennox exclusive features and give Lennox rooftop equipment a big edge over competition both in appearance and installation procedures. Primarily designed for in- stallation on a rooftop with the optional RT8 duct en- closure or RD8 POWER SAVER it can also be installed on a slab at grade level with end handling of conditioned air. The single package unit contains all refrigeration com- ponents (evaporator and condenser units) air movers, air filters, and optional electrical heat in one complete package. The optional RT8 or RD8 duct enclosure and `i 11 OPTIONAL ROOF )4 t ' t ) rl MOUNTING FRAME Ttr S Three Air Patterns Possible Basic unit is horizontal with end delivery of conditioned air. Use of optional RT8 duct enclosure or RD8 POWER SAVER allows bottom handling of conditioned air, 1 Horizontal (Basic unit) NOTE — Specifications, ratings and dimensions subject to change without notice. PAC ' t t E D Febrtub y,1l5y 1970 b'd�fi'#r�� Supersedes 7 r -1 - 69 (6%. cpp4 Optional Roof Mounting Frame Detail Weatherproof frame (RMF3.65) is used w ienever RT8 duct enclosure or RD8 POWER SAVER T . M • Is used. The frame extends around the entire perimeter of the CHA8 and RT8 or RD8. Duct connection and entry into the conditioned area are accomplished within the confines of the frame. Down -flo (Combination ceiling supply and return) RT8 or ROB required Single Package Air Conditioning Unit RMF3 mounting frame easily adapt to the CHA8 unit. The mounting frame mates to the bottom of the CHA8 and duct enclosure and when flashed into the roof per- mits weatherproof duct connection and entry to the conditioned area. No additional roof curbing or flashing is required —the RMF3 frame does the entire job. Option- al POWER SAVER and controls (RD8) reduce cooling costs and satisfy any local code fresh air requirements. Externally mounted optional minimum fresh air damper (manual) is also available. Choice of 230V single phase or 208V thru 550V three phase models is available, 00. J L o u ; . W O; u. a ' Lo. k, w z • O N W W .H U H • W U = O l.. Z Unit Model No. Entering Wet Bulb Degrees IF) Evaporator Air 80F Dry Bulb 63 67 71 63 67 71 Total Air Volume (Cfm) 1600 1800 2000 1600 1800 2000 1600 1800 2000 2000 2250 2500 2000 2250 2500 2000 2260 2600 Outdoor Air Temperature Entering Condenser (F) 85 Total Cooling Capacity (Btuh) 51,200 62,700 54,000 54,300 55,500 56,600 57,800 68,900 59,800 68,500 60,300 61,700 61,800 63,500 64,700 64,800 66,100 67,300 Sensible To Total Ratio (S /T) .87 .88 .89 .69 .72 .76 .54 .55 .56 .85 .87 .90 .71 .72 .73 .53 .65 .66 Comp. Motor Input Watts 5430 5510 5590 5600 5670 5730 5800 5860 5910 6670 6670 6740 6750 6830 6900 6900 6970 7040 95 Total Cooling Capacity (Btuh) 46,800 48,700 49,800 50,200 51,300 52,300 54,000 55,100 56,400 65,000 57,200 58,700 59,100 60,800 62,200 62,200 63,500 64,900 Sensible To Total Ratio (S /T) .91 .92 .94 .73 .76 .79 .56 .57 .69 .88 .90 ' .92 .73 .74 .75 . .54 .56 .57 Comp. Motor Input Watts 5690 5820 6890 5920 5990 6060 6170 6250 6330 6950 7080 7170 7190 7290 7370 7370 7450 7530 105 Total Cooling Capacity (Btuh) 43,000 44,800 46,000 46,100 47,200 48,000 50,500 51,500 62,800 49,800 52,000 54,100 64,200 56,100 67,700 57,600 69,200 61,000 Sensible To Total Ratio (S /T) .94 .96 .98 .76 .79 .82 .57 .59 .61 .92 ,94 .96 .75 .77 .78 .56 .67 .68 Comp. Motor Input Watts 6100 6230 6320 6330 6420 6480 6660 6740 6830 7240 7380 7520 7520 7660 7760 7760 7860 7980 115 Total Cooling Capacity IBtuh) 38,900 40,400 41,500 41,500 42,500 43,600 46,500 47,500 48,400 44,200 46,500 48,800 48,900 51,100 52,800 52,800 54,300 56,200 Sensible To Total Ratio (S /TI .97 .99 1.00 .84 .85 .86 .59 .61 .63 .96 .98 1.00 .78 .79 .81 .67 .58 .60 Camp. Motor Input Watts 6430 6560 6650 6650 6750 6820 7080 7160 7240 7670 7830 8000 8000 8170 8300 8300 8410 8520 i> ii }tit t5 ajr:volyma. per ton, of coo( r1g capacity, 95F..outdoo aair.temperature and $ tiS)i'i% 1 07 -05 -2005 PETER CRELLEY P.O. BOX 33370 SEATTLE, WA 98133 RE: Permit No. M04 -142 935 INDUSTRY DR TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and /or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Permit Center at 206 - 431 -3670 to arrange for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one - time extension up to 180 days. Extension requests must be in writine and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 08/09/2005, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, efk i Brenda Holt, Permit Coordinator City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director xc: Permit File No. M04 -142 Bob Benedicto, Building Official 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665 N g ; N W W( g J' u_ Ul Z U D i O ; - W' 1-- V O, Z ' • ~ O FEB -21 -2005 10:28 PRO-S TA FF° FOR YOUR HEATING. MR CONDITIONING 8 REFRIGERATION NEEDS February 21, 2005 Stephania Spencer City of Tukwila Department of Community Development 6300 Southcenter Blvd. Ste. 100 Tukwila, Washington 98188 PRO -STAFF MECHANICAL 206 361 0424 P.01/01 Dear Stephanie: I would like to request an extension to mechanical permit number M04 -142 at 615 Strander Boulevard. We are having a difficult time interfacing with the electrical contractor for the job. They can't seem to get the electrical permit posted and signed off so I can get my final inspections. I have other City of Tukwila mechanical permits held up for this same reason. Please , extend this permit and I will resolve this matter in a timely manner. Thank you for consideration on this matter. Sincerely, Pro -Staff Mechanical Inc. Tom Reddy Project Manager MED COMMERCIAL HVAC CONTRACTORS SYSTEM DESIGN 8 INSTALLATION SHEET METAL FAURICATION 24 HOUR EMERGENCY SERVICE PREVENTIVE MAINTENANCE ® 0 22 44 VT , _ I v" s-n Pt'/ ti ts , q -2 • Taws. . PRO-STAFF MECHANICAL INC. OFFICES /SHOP: (206) 361 -0071 P.O. BOX 33370 902 N. 127TH ST. FAX: 361 -0424 LICENSE #PROSTMI072NG SEATTLE, WA 98133 SEATTLE, WA 98133 1- 800 - 225.4822 (WA) www.pro- slalfinechanIcaLcom TOTAL P.01 rnw w 0 ; g - Ira Z g` w w`:, o ; o � 11J w c o : U 02 -07 -2005 PETER CRELLEY P.O. 130X 33370 SEATTLE, WA 98133 . Permit No. M04 -142 935 INDUSTRY DR TUKW Dear Permit Holder: In reviewing our current records the above. noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International.Mechanical Code, every permit issued by the Building Division under the • provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not : commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Permit Center at 206 - 431 -3670 to arrange for the next or final inspection; This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned.. If such determination is made, the Building Code does allow the Building Official to approve a one - time extension up to 180 days. Extension requests must be in writing and provide salisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 03/02/2005, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely,. xc: Stefania Spencer, Permit Technician Permit File No. M04 -142 Bob Benedicto, Building Official City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206 - 431 -3665 W;. v co co uj • u.Q. co a O z O H. • D io •F V` V EPA TR MENTS: Buil�iftig 7ivi n ' trk Public Works ❑ APPROVALS OR CORRECTIONS: Documents/routing slip,doc 2 -28 -02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M04 -142 DATE: 07 -29 -04 PROJECT NAME: SEATTLE'S FAVORITE GOURMET COOKIES SITE ADDRESS: 935/939 INDUSTRY DRIVE X Original Plan Submittal Response to Incomplete Letter # _ Response to Correction Letter # _ Revision # after /before permit is issued Fire Prevention Structural ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 08 -03 -04 Complete II( Incomplete ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS RO)JTING: Please Route , El Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 08 -31 -04 Approved ❑ Approved with Conditions [f Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: PERMIT COORD COPY Planning Division Permit Coordinator Not Applicable ❑ DATE: License PROSTMI072NG Licensee Name PRO STAFF MECHANICAL INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601038859 Verify Contractor Premium Status Ind; Ins. Account Id 52073600 Business Type CORPORATION Address 1 PO BOX 33370 Address 2 City SEATTLE County KING State WA Zip 98133 Phone 2063610071 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 8/7/1993 Expiration Date 6/30/2006 Suspend Date Separation Date Parent Company Previous License PROSTHA136NJ Next License Associated License nW �w_.�_�v ........�._....�..___�....�... _..._.w....._�.....,� Look Up a Contractor, Electric "7 or Plumber License Detail r --. Page 1 of 3 Topic Index I Contact Info 1 Search Horne Safety Claims & Insurance Workplace Rights Trades & Licensing Find a Law or Rule : Get a Form or Publication Look Up a Contractor, Electrician or Plumber General /Specialty Contractor A business registered as a construction contractor with Lai to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. License Information Business Owner Information Name Role I Effective Date https: // fortress. wa. gov /lni/bbip /detail.aspx ?License= PROSTMI072NG 09/03/2004 W ii V! 0 m W ; u. a ! F W; Z 1— 0 Z 1 p : O N o1- w Z' w Oti co File: M04-0142 35mm Drawing #1-2 r REPLACE AC -1 WITH NEW A TRANE 3 -TON GAS/ELECTRIC AC UNIT. "LIKE- FOR - LIKE" REPLACEMENT Permit No. Phn review approval Is subject to „Fors and Appoval of consbuction documents does not the violation of any adopted code or of approved Feld Copy and conditions is .m�o�na= No changes shell be mode to the scope of work without pry approval of Tukwila Building Division. NOTE: Revisions will plan submittal and may indude a plan review fees. a,0 5i7N C1 Reomtoo M EXHAv5T ROOF PLAN SCALE: 1/16"=1'-0" REPLACE AC -2 WITH NEW A TRANE 5 -TON GAS/ELECTRIC AC UNIT. "LIKE- FOR -LIKE" REPLACEMENT SEPARATE PERMIT POR: OA Medianical ur Electrical 9l Plumbin e Gas Pl Pn9 City Of Tukwila BUILDING DIVISI • 0 0 E�c,rIr-4c� F�vr_ ✓► =t�� s 0 REVIEWED FOR CODE COMPLIANCE APPROVED D SEP 01 2004 City Of Tukwila %%.ING DIVISION 0 1 111111 l l ,i�s r •1 1 1 111111 I l l l I I I I 1 .I I l I I I I I11 1111111 -1 I I I III _ I l I1 I I I l _. I I I . 111 111 111 4I 5) I 6 I r 9r• t7 E I. LLB .., OC. 6 L.; 11 11 I I 111 I I I I LI I_l.l I I 111 I I I I I I l l I I LLI_L.I I I 11111 I LiI I I I II I • i IIIIIILIIIIIIIIIIIIII I IIfIIIII III I I 1IIIIIIIIIIIIIII Min ler Blvd J Strander Blvd. 31 26 /28 Phase IV Phase V G 'e SCOPE OF WORK: Replace',�ewsting Lennox AC units with new Trane AC units. • One new 5 -Ton unit and one new 3 - Ton unit. • Two new economizers. • Associated transitional rooftop ductwork tied to the existing ductwork curb. • Two new programmable thermostats. • Crane. • Equipment start & test. Parcel Number: 253049034 LEA • G OFFICE Stra ' er Blvd. d i . A, uite G 1%41V Q1 Qi e. IC) 0. • co roi c h V tai yy ct N H en C N (J REVISIONS PERMIT CENT DRAWN 1 C. DATE 7�i s/o4 CONTENTS JOB #1002 SHEET NUMBER M -1 NEW "LIKE- FOR - LIKE" ROOFTOP REPLACEMENT SCHEDULE TAG AC -1 AC -2 Main Service Ste. #939 Ste. #935 MODEL # YSCO36A3ELA YSC060A3EMA SIZE 3-Ton 5 -Ton CFM 1,100 1,900 MIN OSA 120 400 COOLING (BTUH) 37,400 63,100 COOLING' SEER 10,7 10.20 HEATING INPUT 60,000 80,000 HEATING OUTPUT 47,000 64,000 AFUE 80% 81% ELECTRICAL 208 - 230/3/60 MCA = 17.9 FUSE = 25 MCA = 31.5 FUSE = 50 Sound (dB) 83 84 EQUIPMENT NOTES: 1. Economizer. 2. 7 -Day programmable night setback thermostat with 5 degree dead -band capability. 3. Outside air intake to be 10' - 0" from exhaust outlet, gas flues & plumbing ents 4. Existing Units being replaced: AC -1: Lennox Model CHA8-463, Weight = 607 pounds. Weight AC -2: Lennox Model CHA8 -653 g - .�, - 807 pounds. IIIIIII IIILI�I 111 I 11 2111 1 I LL Ijl i I i IjII l�.1 1Ii III IIIII1I jIl 111 ICI III II Inch 1/16 I I I I 3 I III 1 I I 5I I 6 I i...1p a I L,: � III I�III ll 6 8 L.. ;0._ 5 q ,; 111111III I. 1. HIC111111 .1II I 11 z 1419 llll � l IIIIIII�IIII �1LIIIIIII�IIIIIIIII�IIIIIIIIi� lllll 111 I �IIIIIIIII�IIIII WEIGHT (LBS.) 513 555 ---''" W F E REE COMPLIANC CODE goon cor.n 0 2004 S City Of Tu BUILD"OG DIVISION SHEET NUMBER CIJ .� o 6 14 � ,t &e, 0 � u Q1 N t 0 Ei M o fu tn ; cd ch N REVISIONS 4 TY OF 71 W a J UL 2 9 2004 PERMIT CENTER DRAWN ? G DATE . 7/2. E3/a4 CONTENTS JOB #1002 M -2