Loading...
HomeMy WebLinkAboutPermit M03-007 - KELLY GOODWIN HARDWOODSKELLY GOODWIN HARDWOODS 350 TRECK DRIVE EXPIRED M03-007 Value of Construction: Signature: Print Name: doc: Mech City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Permit Center Authorized Signature: ii/(,ti/l/ Z a • Parcel No.: 0223400045 Permit Number: M03-007 Address: 350 TRECK DR TUKW Issue Date: 01/15/2003 tY Suite No: Permit Expires On: 07/14/2003 t6 U 0 0 Tenant: Cl) C Name: KELLY GOODWIN HARDWOODS co = Ad dress: 350 TRECK DR, TUKWILA WA co L W O Owner: 2 Name: PANKRATZ FOREST INDUSTRIES INC Phone: g Q Address: P 0 BOX 58388, TUKWILA WA Et-) u. Contact Person: _ Name: MARK SMELTZER Phone: 425- 251 -0360 Z f" Address: PERFORMANCE HEATING, 7649 S 180 ST Z 0. wW Contractor: 0 p Name: PERFORMANCE HEATING Phone: 425 251 -0356 0 to Address: 7649 S 180 ST, KENT WA CI H Contractor License No: PERFOHA15ORT Expiration Date: 04/28/2003 = w DESCRIPTION OF WORK: u- O REMOVE EXISTING FAILED ROOFTOP GAS PACKAGE AC UNIT & REPLACE WITH NEW UNIT OF ui Z SAME CAPACITY IN SAME LOCATION. MODIFY EXISTING ROOFTOP DUCTWORK TO SUIT NEW 0 UNIT. 0 F' Z J (U0// 3/0 MECHANICAL PERMIT $12,000.00 Fees Collected: Type of Fire Protection: Uniform Mechnical Code Edition: a Ak t,U`- -- Date: / - /6 - 03 $46.50 1997 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M03 -007 Date: Printed: 01 -15 -2003 Parcel No.: 0223400045 Address: 350 TRECK DR TUKW Suite No: Tenant: KELLY GOODWIN HARDWOODS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (296- 4722). 4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 6: Readily accessible access to roof mounted equipment is required. 7: Any exposed insulations backing material shall have a Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 8: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 9: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 10: Manufacturers installation instructions required on site for the building inspectors review. 11: ** *FIRE DEPARTMENT CONDITIONS * ** 12: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 13: ** *FIRE ALARM SYSTEMS * ** - City Ordinance #1646 - NFPA 72 14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1900) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) 16: Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2)) 17: Duct smoke detectors shall be capable for being reset from the alarm panel. (City Ordinance #1900) 18: Duct detectors shall send a supervisory signal only upon activation. 19: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1900) 20: All new fire alarm systems or modifications to existing systems shall have the written approval of the Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1900) (UFC 1001.3) 21: Call the Tukwila Fire Department at 575 -4407 for approval of any system shut down. Have job site address, name and Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #1900) 22: ** *ELECTRICAL * ** UFC Article 85 - NPFA 70- NEC 23: All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 24: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 25: These plans were reviewed by Inspector 510. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS M03 -007 Permit Number: M03 -007 Status: ISSUED Applied Date: 01/13/2003 Issue Date: 01/15/2003 Printed: 01 -15 -2003 uca Signature: Print Name: doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. ) f ).6%,"1,67 M03 -007 Date: / it 103 Printed: 01 -15 -2003 Project Name/Tenant: Value ofr echanical Equipment: Site Address : ' t b rre - l Prt Ile Tuko [4� 98 f'�� 7U CC L/ Tax r Num Ooo4 6 Property Owner: l rqn kr d z . rote'+ /ngqsirl e Phone: () 575 .-2525 Street Address: City State /Z to. 30x. 58386 Tukwtfq Wl� 98133' Fax #: ( 679 _155.3 Contractor: . Per�or�lartce lead - h A C�hc�t f ion i J Phone: ( ) fz5 I51 -03 r' Street Address: City o3 State/Zip: z 16 7 S. fg - s4 • ie nt-, WA �R G) Fax #: ( 4 •C! Ai , o�60 Contact Person: Mark Smellier Phone: (4 030? Street Address: 1649 5. i0 , c , g (-' A 98 o tState/Zip: Fax #: (125 ,29 • 0280 BUILDING ;O :AUTHORI ED'AGENT: =' Signature: Q_ � Date: / _ f _ Q 3 Print name: /star Siteltzt✓ P hone: (426)A9/0356 Cit /State/Zip: /L _ r , ,,, Fax #:.(425) 11;03 Address: /641 s. :3^ Q CITY OF 7 'KWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. MECHANICAL; PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) Description of work to be done (please be specyfic): geMv✓e Oc. 5+ � a.i leci f o 5 reduce w /meld of sabre c ach ie) Sinn lo ca1oti . J Moc�t>�y ekcs1;i exis��n »� g too sad mw ��,. . e Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: Date application expires: 7 -13-03 Application taken by: (initials) Uk 11/2/99 itch permif.doc ✓ Submittal Requirements Floor plan and system layout '� Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Nit. Details and elevations (for roof mounted equipment) and proposed screening , NA. Heat Loss Calculations or Washington State Energy Code Form #H -7 / ✓ H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). ✓ Specifications must be provided to show that replacement equipment complies with the efficiency ratings .,and other applicable requirements of the Washington State Nonresidential Energy Code. fructural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal RESIDENTIAL: Two complete sets of attachments required with application submittal 11/2/99 niiscpnu.doc NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. Submittal Requirements New Single Family Residence Heat Toss calculations or Form H -6. Equipment specifications. Change - out or replacement of existing mechanical equipment . 1 Narrative of work to be done, including modification to duct work. Installation of Gas Fireplace Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe condition. NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 RECEIPT Parcel No.: 0223400045 Permit Number: M03-007 Address: 350 TRECK DR TUKW Status: APPROVED Suite No: Applied Date: 01/13/2003 Applicant: KELLY GOODWIN HARDWOODS Issue Date: Receipt No.: R03 -00045 Payment Amount: 46.50 Initials: KAS Payment Date: 01/15/2003 02:58 PM User ID: 1684 Balance: $0.00 Payee: PERFORMANCE HEATING TRANSACTION LIST: Type Method Description Amount Payment Check 19095 ACCOUNT ITEM LIST: Description doc: Receipt MECHANICAL - NONRES PLAN CHECK - NONRES Account Code Current Pmts 000/322.100 000/345.830 46.50 37.20 9.30 Total: 46.50 4476 01116 9716 TOTAL 46.50 Printed: 01 -15 -2003 COMMENTS: 1.) ..- i l 'ev - c ArC.. c 0vlv�PcA S M C)IC.e A`P c. - VO)r s-.\--1-) c > et w ?4,v ( l f I c . tr■ Ye e4 q - L - 1 v� s P C - A- I O In ` 0 �? 2.� Use 3 /=K >c 3 1 ctr 6)4 5 1 hAo M k- L-1 v- sky- uckuict \ rt.ola i if., 3.) \Jrv^; -Li a pp r nv � eA t O' -e I-ec v(4 1 4i , ..a\ 1 Reques st te r r: J7 r1 / Phone )55/ - d / 7 Project: 7G ' �s Lv /rt) Type of inspection: ,�iN� -- It /FC/4 Address: ,__.-_ ,, .Z)/ Date Called: - �- Z / �rY Special Instructions: F �� C J / /ll E � Ov 4Jr/ Date Wanted: a.m. 5.- ,0 3 p.m Reques st te r r: J7 r1 / Phone )55/ - d / 7 INSPECTION NO. D Approved per applicable codes. Inspector" • INSPECTION RECORD Retain a copy with permit /23 a27 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 orrections required prior to approval. Date: 2- 1 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: MI filth Amur Suitt 900 Softie. %shintun 91101.I6I0 106 113 0717.In 106 3115 ,ww.tolfmanom January 13, 2003 1n:1 Lily riuGr[J Mr. Mark Smeltzer Performance Heating & Air Conditioning, Inc. 7649 South 180 St. Kent, WA 98032 Project: Kelly- Goodwin Hardwoods 350 Treck Drive Tukwila, WA 98188 Subject: Structural review of existing framing for new Air Conditioning units Dear Mark; We have reviewed the existing roof framing of the above building. Our analysis is based upon existing framing information provided by your firm. The framing consists of 2x4 subpurlins spaced at 2' -0" o.c., spanning about 8' -0 ". These subpurlins are supported by 4x14 purlins spaced at 8' -0" o.c. and spanning about 20' -0 ". These purlins are supported by 8 3/4" wide glued laminated beams spanning about 60' -0 ". You have provided the unit weight as being 866 pounds. This weight includes the econo. and relief weight of 46 pounds. Our analysis shows that the existing joists and beams are capable of supporting this unit and will not need any additional reinforcement. Please call me directly at (206) 521 -0759 if you have any questions. Sincerely, COFFMAN ENGINEERS, INC. Marvin Emerson, S.E. Structural Engineering MDE: cjs 030221et011303 PHAC Gray. Review Spoaant. Wt,sniatton 109 110 2 991 Anchorite, aluka 907 116 6114 FILE COPY lot Anttla, Cdiforen 81e IBS 2650 GV1bbd43' F'. Sid OFFMA N G I N E E `. 1 CAP( Of TUCK A APPROWD AN 15 2003 ffED RECEIVED : CITY OF TUKWILA. JAN 1 3 2003 • • • PERMIT CENTER 00 N 0 . W W: J LL m u Q m Z ` � I— 0 Z F - . uj m U � O N, 0 1- W W O ..z f= _ O 1— z 1 Roof Top Air Conditioner Unit Replacements Kelly- Goodwin Hardwoods 350 Treck Drive Tukwila, Washington . STRUCTURAL REVIEW OF EXISTING ROOF FRAMING January 13, 2003 Prepared by AFOFFMAN 1601 Fifth Avenue, Suite 900 Westlake Center Office Tower Seattle, Washington 98401 (208) 823.0717 GUDOGMJ f f G . JU U 0 � CO CI ww J ; CO U. w g a u_ a. D. a D. z �!. U 0 Di 0 Ht 2 U I— LL Ili .Z O Z 1 1E4 G otoloct P. 1 /5, ri 1G 7 • 6•06/) location k ov,LA 1.1/ cIlnI by 0 date 11D0 chectma ehoul no,.;;£ ' • jab nO• t." ' • . Asstim„.“,- u telaHo ! ' 4'. A. C. VILD S cA)ck30 Do 1 ',; . : ' •',.. - .1 •,'"7: ,--- 17. ...: .: . , 6) . P 62 t" P 0 5 Cre 0 I I"' G wool) S q./F..posg l ,,, /7.i L (1.. / l p,•-al s .; • -- r'sfr V H .'.i. , .1.::. '..: ,F•1 4 4 ...... _ ._ .!..i.....i .; • s . 4:i . I • ..: , --—•---- ' , •.:!.. ' 1 . r: • - • • •....i.::212..;'!...: ' :,, '-! r'.? 1.i. 1 .• i. ' ..„,o ,„c,ri) 5S v14 ' • 4' ' • 1 1..1 ILA 11 r.« / IA/ (7 d'Th 0.4 14 F; AA F in V ek, M b 2 0 G.0.770 S bee op ■=" 57 )b- 3 PSI P C,.0 c. C Cfc Pst.c•-6•7)(0,(=1)(1)(1,1) ir (6sof ) 0 4,6 tf/70, ooe,s;K . 0. *IT xfSr, Ai G. 3 •, (3 Pon, id ( IC .,s, c A s fa ) dUbbd / eV ,/t/ * ^ •1 ** ** 1•: • • •1 .5 . .ji.. • T dale • . ••• 0 Pe. •.. • 1<.1 • !' I • • . •.; 1 I ! . p rx g. 5 ib ( I 1. Ca) 3 Ito •,; , I jr (( X- -1011 "'t (o p-) -.7—• 2 Altu 0: (:"-- . • •: : I 1 . ••••• (re4 0,, a • I.; S M .4. 7. 1 . • 1) • " 4 • .;• :1 ' 4 ••• ' -2 I : 37 ;7:14 - f 1•••• 1k. ff .1.22 44. / P c' • • ''''' . 1_2 ' ... I r -,.....„ I b eco'a..14 1..3 I 4 1 V O P $ t! de" • rt : I. .:. ' ''.. :4 ‘ .) urn, ..., e..". if d / . . / ,..) CV 6 Y ro .5 L•r .0 K. ..kri...m - 4 .• : - • A COn. s•Al nt.Lort t 7 '"'Jf' T./ S . • :717- • . r1 v 0 sv C OA" 7)0.)v:1i: D Y o (CY 5 ') (')c;') r. " A 5 Su p w (r Lt. T.' q, ?r 7 ; f ON 2 (,,0,3 AFI c ?M 372% 233)6 4 4. 73 !f/ 7 .4 P.si "3" r rift az•—•': ..-,,_ ; -.:: C ' . S'. )(u)( Ott) T nf c OS OK. 1 '. ' 4 -:- 1:- ....,, ( c 1 :, , - , 1ip.- ):: :,,,,... r ., :2,- :-i 6:: ei . i , 4,..,; - ,0 ( , c) F .,„ 7 . 9 ^ow!' 17 0/10 : or ;if? ..S A 8 3 /1X 30 "-•: A 4..,Fs. PO piocct P- •04. C. beacon 7 Mint t;) ti ft CI. 4 11.7- 0 1 5 S' V..) C ti el V. 2 0. f1 I . • /9 — 1 3 • I • • • • Al • . • . -.L.- • 4 1 () o br.;• ": ; : 1; ; • *- , t.) • (r.08.1 '4 ...,....... Dv A date :3 •1 t, 3 CMCKtd disk, •• : • • • • ••••• • • •• • ., •••:, . • OnSiol • •,; S : a4: • • 100n • ••' • ,‘ :I • , Ir• ;•• ,• • e' 74 All dimensions are in inches/millimeters. 6Ton Satr7drd and High Efficiency 7s4 ibn S andad E1lFckFKy SAN -10 -2003 10;0e 10k EWVQtTATOR$ECTION ACCE!! IIdNCI AtfIMMIE OOMOENytpe ORMN WMPKCTION ltd. ¶4 MOT OIA. HOLE 714 Trim Ellidancy H and 7O,, U Standard and High Efficiancy 100 PM VI OPT WO COMMECTIOM IN .a Tao •401. !M Mn aM comEtTOM (!b •■■,7ID•g4 MO *My E KCFVI n AVINAme 00+tnFATF Neale 0 00 1 +1v'nc i Y1. Id tdR ON KU I NI Dimensional Data 7/ 1Vc a o I e += t w` . 1n A.T OTe commiC•pM 110.4% Wrist 0sr ANT tW CO•.wA: ApN b.r.. 701 Pm 714•4•4 425 251 0280 1 CONTRO . AMO CaMRREUOR ACC!!! 'WFl • IMO Fs. / 1•14141 r.. • CON r6: •■0 G0M084100M •CCE11 : 461441. 'Pa l rftli,IV TOP PANEL AIM —WO 44 . 147 tol TY d1 tAM 57 1A1' CO FAN • COMOEN3UI conc..' ` ,= Wu7 O.inkaiW01E TA' (IZMM) DIA now *Epve6 336 om.CC F i , �t'LSW1yDU►�HOIt • 1 ~ 1l�lWMLpHOLE Z z re U uJ W = U_ w0. I w H w L I O` W Z O z 3 3 3 ' • • /1 f 347 L • . .rtr • . . . . • . " • • ,.. • • . • • . • . . , NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. fatt1-1 to 4 F RTPfC006.EN NOTE: -- t. Caner walgllb Ma Own td irdOrmal only • We J/s 000mttiteA. JRN- 1W -?AA'i 10:01 ..... . . u ... a .• 4 I .L.LI..J Weights; YSCO36A 53x1 480 151 3 YHCO35A" 551 487 158 4 YSC048A 559 503 159 YHC048A 593 539 166 6 YSC 578 522 • 69 VREF504 626 574 • 79 O • YSC072A7•14 822 735 ;49 YNC07243•H 959 772 ;49 1 �CW0.43•H 307 1200 !71 �1 YSCQ3ZA1'H 909 - 822 7 77 VH0002A3•H 1010 923 :736 8A YSC102A3•H IW YHC 102A3.14 1044 t0 •5C1211A3•N 1074 YHC120473•H 1147 r A 1 CENTER 01 wAwn wiom 499 :'37 957 :fir 997 15 1080 :42 0 CEMTEN 01 V C411/6R OF ONAV7TY • /EM81N Atta425, Et •momttir 9:71uneMo R11i.1 R Netad Exhaust M:todnd Oxide Alt Oarnoer M weal Outside Air O mper Tk M Curb A' ^1C4 r>" Inn rattle lArtl - Maximum Un/tAnd Comm (*fishes (LW And Cantle Of Grarlly Dimensions (1n.1 Unfl Maximum Weights tltrol' Corner Weights (U»I1 Tone Mod51N0. Shipping Net A 6 124 128 130 133 136 140 193 198 209 243 243 262 295 277 96 101 109 114 105 119 132 141 146 147 166 165 175 783 187 2 tbi• W2 - Irwttoty4nsoat.dOptione Nee l,% gds Oar GyJppaH.) r 1 J 109 110 109 125 114 7S 161 181 143 175 210 144 220 248 0' Iwl,.sa Meioi 5 64 •: Drive Motor 31 Snort. • • • •r netutn 7 5n1211e Detector. Supply 5 Col Guerra 12 Mr tied Doors 10 Pe Wed Conwnilnce Outhrt 38 Though the floes Cleanest 8 Thrnighme Save Gas 9 Un t MoWlted C1ruYlt 6m1*N 5 Unt: Mounted Dia nnect 5 :1r Control a Not I :S: t.W. • anis 70t o01.0,'i n01 74000 tint >5 706. 2 Nit MOM ttteud h 10611 to unit wool nttcn udcrwp tp alrv•.8I6760 OCCtptXNi. Center of Grawty Iln. ?•: _ i; O Utnath width Tr : 32 19 33 19 3 m 18 21 2Z se.. ;:i. Net Vino 3GTona 8.101one 20 30: 18 28 70 115 • 39 22 40 21 39 22 .: 40 21' 40 22 .._{ 40 21. 40 5 a 20 72 38 .10 5 5 5 9 79 .7 1 1601 fDI0 Avenel Suitt 900 So W 98101.1610 266 623 0717.laa 206621 311 S wwtollmtn.enm January 13, 2003 Dear Mark: Spokane, Washiaplon S09128 2991 Mr. Mark Smeltzer Performance Heating & Air Conditioning, Inc. 7649 South 180 St. Kent, WA 98032 Project: Kelly- Goodwin Hardwoods 350 Treck Drive Tukwila, WA 98188 Subject: Lateral Analysis of new Air Conditioning roof top units I Enclosed is our lateral analysis of the above unit. Our analysis is based upon unit dimensions and weight you have provided. The new unit weighs 866 pounds. This weight includes the econo. and relief. For attaching the new unit to the existing roof, our analysis shows that #10 bugle headed screws and 3/8 inch by 3 inch lag screws are required for seismic zone 3. Use (2) 010 screws to attach the new unit to the new 12 -gage angle, and use (1) 3/8" lag screw to attach the new 12 -gage angle to the new 4x4. As for connecting the new 4x4 to the existing 6x6, use (1) 3/8 inch by 3- inch lag screw in each and use a 12 -gage angle as the transfer angle. Note the new angle should be at least 3 inches wide and each leg should be at least 3 inches long with the lag screws applied on the centerline of the angle and centerline of' the wood. Verify that the existing 6x6 is attached to the roof with the same amount of screws or bolts in a similar manner. Please call directly at (206) 521 -0759 if you have any questions or concerns. Sincerely, COFFMAN ENGINEERS Marvin Emerson, S.E. Structural Engineering MDE: cjs 030221et011303 PHAC Lat Analysis AmAOrote, Alaska 901 276 6664 Lot Amite. (Weenie 818 186 2600 C4 2 111 00 N o. tow to Nu- w O' g N d Z ,- U •O N . o w w: 1— - U- 0. ta Z: O 1-` Z vim, s 11111 VI , 411 •L.L1 \.J Roof Top Air Conditioner Unit Replacements Kelly- Goodwin Hardwoods 350 Treck Drive Tukwila, Washington LATERAL ANAYSIS CALCULATIONS January 13, 2003 Prepared by: A 1601 Fifth Avenue, Suite 900 Westlake Center ONIce.Tower Seattle, Washington 98101 (209) 623.0717 ctJbbe f rD r. 11 z Q • W . re 2 V O . N o: co w , _. U) U. w o g Q. D. a � _ ; z �.;. z o 0: W uj D o O in O — O I- W w 1 O . ui z" O ~: z . •A. 77.74: L • IFFIFIFNNEEP R S wince! e. 4 -. a 00 0 (A/ Id ',motion 7-J 14 chsrn P C.. b fror-z age r 0 3 t date mem S•-•:*"•••= Job no. a 3 2; • P/ A/ ) ea /• 7 t/ ( 0 6) = I% /. 2 y ( 1 /6 / ) S '716 2• 8 415,6" to 1) r1•4 / • , L•!: 1 0. S4.0 • A: 1 4 /9.7if C. A pqm. 1 .:!• 3 6.3 ' /a2* 0Coet4 sa v.77 P . _ • 7 • — 76 7 6 vpie .(?(L4/3 a lQO -- 2 $ cata.4i, ( 6.7 ij o,i?i1 ,s. 1' W0 pr 3) C. creel it. ry. 7 7 4:. ...“904)( 14 se faelma 6U4. Sfoeo 37/777•-• / 1i) 1,4/ EL.J C.... c)III eb,P ri • et el ••■• • I r_s • e 0 - 7 €1 cd.13 ) / ; )( of • s- / kg " a . trof:Ale_.rtilk R 0 vALVIS 2 • _ . ) x rz„ ) 5. 4r •••• ■ ■ ,q k ,:.6„ Hat 0 De,444 4/ 2 - / - /.9 tc cr - „ ..L do (3etolioXr..13)(0.1)(r)( 0()(0(,) 7. 4 leanwii 3*. a • e o•art ' `-• scq.rtid 112/ Le' 4(,.. g l i f 3 Y,.)( -7 = atioo.4-1 f f r • e_ /I /4 A,. c z c,•• -r Ita.r/01.4)- 76 7 eb . C..?1 ! 0 • 5 t 1 ‘• 2, 1 - •;,IL:4-24 • • i s'/.1 /iV • •• : ••••„i • • • • • • , • • ( eeSeev6- *".9 S , " P set 4 ff.- 7 ' ,J.' 3 ' • Se•'• /4-: -feelo4' 41"11•?••.: el gt I Ai 04 4. k ri. 7 / At . • .. • . . 1- • i w--c-7„ 1 -' 3 Cot.; co, a) 2: „ !..' 7- 11 co CA. c • C C 3 " I - 3. * : ' , ',... ':•1 . • . : : • .• i 1 ; 4.0 1 Pit /L, 0,... ......L . , gig • ;^• - • - ; • • _ of •• r .u.r .L�i. dL�bbG43'f'f + F'. l i 4.•e-1 7 1 2 . xi" LA? [. Y J' O rG' M t6. c.'i! • L. Al i i ' :G FIF E • 7 J (L IN P A c_ A i by N n R Mgt I /v3 fo1 flats Sheet • ob.,. • O 3.a 2;t2. `! L /f•G• cvNA/. r..dAI r; . G/dt .7 G. eK 16 15 / rora•- (335 / `l 3crtriuSI7trrA 0. 5 7 -1' O. 2 .S r o /ov4c,NJ IQ 2 6/ e. o.J.- c o.+rJ. L.rkG O. z I. 0le. vs15 34.. x 3 A 6- / A e) 0 (2) t e o .5 ca. MA/ S w/ • i fidG / -r/ a I; 61 /'i �. K r S r - /'2 6-4 G-(2 /a.JG.c k • . ' . 7rr •�• .r• • . TA1.I -4 A— ^1rary . n. Mr, •%".•••• • 'j r•1 • • .I':It : ,•1. f .. •, .. �. . 1 .... I 1-.1 I I 1 11-.1-.1 •.J • .., . • 1.. ••+ • •,, ; • ;� .,., Ill ,: •. � ►•,1 .� •. 1 1 ..gat; 1 �. • •‘• fi ;y • • • j• • O .I..••y . �- N • ! --... ; • :. •` { • 1 I .• . •I, i ..' tel00C4JI IJ r. . 4 j 1 , ,•c • 1 .; ,.' . , • '�1<^ .., • • ' TOTAL P.14 Q H z r 1U 0 0 U) W J W 2 co d = W H = Z F- 0 Z F- W 0 0- 0 H W W u. O U= O ~ z July 3, 2003 Mark Smelter 7649 South 180th Street Kent, WA 98032 RE: Permit Application No. M03 -007 350 Treck Drive Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and/or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to August 4, 2003, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Stefania Spencer Permit Technician Xc: Permit File No. M03 -007 Bob Benedicto, Building Official City of Tukwila • CaII the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next or final inspection. Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206-431-3665 x"'7649 S. lee St. Kent, WA 98032 426451.0386 Fax: 425.214 -0280 To: John M. Nissen, S.E. Fax 206624-3775 Pet Kelly- Goodwin Hardwoods John, JAN - 10 - 2003 twee iron+: Mark Smeltzer Pages: 4 Pilaw 206 - 623 -0717 Lae: 01/1001003 CO: file O Urgent l i FYI PI Please Comment Hind Copy To: Q Follow E1 Will Not Follow Please provide proposal for shvctural & seismic revii :w of the above job located at 35017eck Dnve, Tukwila, WA. 98188. The work involves the replacement a rooftop gas package AC unit with a new unit. Attached are catalog cut sheets showing equipr'rent dimensions & weights. The new unit will be placed on new 4x6 wood sleepers that straddle exicting 6x6 wood sleepers. I have e- mailed you a drawing stowing existing roof structure & proposed location of new snit. Please lot me know 0 there is anything else I can provi :le you with to aid in your review. Thanks, Mark 4 P5M c.000G` l I J r.r�o Perfonnai eHeatin &AirConditi Heating toning, Inc:•: w V pit CC ? ., UO N w _ . LL: 2O : I J LL = if. w Za O N: 0 t— ill ID H U - -, u. 0 Z . UN O ~ Z ACTIVITY NUMBER: M03 -007 DATE: 01 -13 -03 PROJECT NAME: Kelly Goodwin Hardwoods SITE ADDRESS: 350 Treck Dr. Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Is Issued DEPARTMENTS: AUK/ 144-6 Building Division Public Works Complete E Comments: Documents/routing slip.doc 2-28-02 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) TUES/THURS ROUTINE: APPROVALS OR CORRECTIONS: PLAN REVIEW /ROUTING SLIP 51D G g " Fire Prevention 0 Structural Incomplete ❑ Please Route 1 t{' Structural Review Required REVIEWER'S INITIALS: Approved ❑ Approved with Conditions REVIEWER'S INITIALS: Planning Division Permit Coordinator ❑ No further Review Required DUE DATE: 2-11-03 DUE DATE: 01-14-03 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ LETTER OF COMPLETENESS MAILED: Fire ❑ Ping ❑ PW ❑ Staff Initials: DATE: Not Approved (attach comments) ❑ Notation: DA TE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: e25- 052_0n0 t8A}71 DEPARTMENT OF LA13OR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL REGIST. # CCO1 PERFOHA150RT EFFECTIVE DATE PERFORMANCE HEATING 7649 S 180TH KENT WA 98032 DLLu 1 And Display C'ctlific.ItL. EXP. DATE 04/28/2003 12/30/1985 & A/C INC 5 o w W N Z w M V W O s--- F- Q - w U a Z W QQ 2 D: U O' W W O: g J' 1L Q! N a Z F F- O. Z 2 V0. W W' 0; • Cu Z U =; OH Z OUT TO F FILE NUMBER OR NAME OUT D DATE O OUT TO F FILE NUMBER OR NAME OUT D DATE O OUT TO F FILE NUMBER OR NAME OUT 1 10 Chilt0 eciii 1 1 4 _1 . S ine= No. xon HASTINGS. MN. — LOS ANGELES _ w. — sIoOREaos . TX. — LOCUST GROVE, GA. vs.s. 1111 NOTICE: W THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. I ...., _____ 1 1 1 1 1 1 WW1 ! P I 8 -3/4 S.LB 1 1 TA6 RTU -I MANUFACTURER TRANE P �V DESCRIPTION O r 1 10- ;/4X8 -3/4 G.L. GpLUNM. TYP. SADDLE. TYP. �1 1 1 1 1 ROOFTOP GAS PACKAGE AIR CONDITIONER T - I G r . p 1 I 8- 3/4x28 -I/2 61B REMOVE" fitt116 f=AttEt°1 — i)NIT d AGE W/ NEW RTU -I. 1NTfALL 4Xh .5 EE TNAT ARE PERO. TO EXISTING bXb SLEI PERS (5CC A.TT HED STRUCTURAL RE I RT — FOR FR .: L ATION). I UNIT TO a: ISTING SUPPLi d RE -� PUGT . ■., Si O 4. NEW DUG 1 MODEL NO. p 1 1 1 1 1 1 1 1 1 8- 3/4X34 6.LB. 8- 3/4X28 -I/2 W/ 2" LIIPR CONNECT}IEW TO EXISTING YSC,0W0A4RL AO016 1 EXISTING PUPPLY DROP THIRD R _ y EXISTING PE TURN DROP THRU ROW 15 2800 HVAG 05" PARTIAL HVAG PROOF PLAN SCALE: 1/4" = I' -O" NOMINAL I INDOOR FAN TOMS (,FM SP 2.0 1 f 1 1 1 SIMI II • MINIMS r 1 91,200 g0,000 1 1 EQUIPMENT SCHEDULE CAPACITY - 9111 HP HEATING COOLING EER/'5EER 103/ 1 ARUE 81% 1 1 NEW Rik)-I NEW 4f WOOD SLEEPER TYP. — CORNE MIGHT, TYP. t 1114110 a IPPPIEW EXISTI 6 bX.; WOOD SLEEPER. TYP. NEW DIILT W/ 2" LINER - .,�._- ----. 1 HSPF VOLTS 460 mooloor ii 2X4 O 2'-O' O.G. TYP. 3-1 /2X 13 PURL IN O 8' -0" 0.G. TYP. b' THICK TILT -UP CONCRETE WALL TRIGAL PHASE MGA 22.6 3m MOCP 35.0 (dB) 90 r M IN. O A LATION OM) '866 800 ROOFTOP W/ ECONOMIZER 4 SMOKE DETECTOR 'INCLUDES ECONOMIZER d BAROMETRIC RELIEF VICINITY MAP SCALE: NONE afaattrahigaLha 0223400045 ANDOVER INDUSTRIAL PARK *5 POR BE NE GAR TN WLY AL6 CURVE TORGT RAD 40.28 FT CENTER BEARING N 04-42-41 E G/A 01 - DIST 12.19 FT TH N 84 -25 -51 W 1 g8.1i FT TH AL6 CURVE TO LFT RAD 410.28 FT C/A II -03-01 DIST 19.13 TO TPOB TH CANTS AL6 CURVE TO LFT G/A 5q -31 -11 DIST 42b.93 FT TN 5 88 -56 -47 E 16.41 FT TH 5 45 -37 -41 E 10.32 FT TH 5 88 -16-11 FT T-1 N 01 -41 -28 E 292.32 FT TO TPOB LESS UP RR OPER R/IN OF WORK:: REMOVE (1) EXISTING FAIL. E ROOFTOP GAS-PACKAGE AIR CONDITIONING UNIT 1 REPLACE WITH NEW UNIT OF SAME CAPACITY IN SAME LOCATION. MODIFY EXISTING ROOFTOP DUCTWORK TO MATCH SUPPLY i RETURN OPENINGS OF NEW UNIT. CONFECT NEW UNIT TO EXISTING NATURAL GAS, LINE VOLTAGE, 1 LOW VOLTAGE UTILITIES. NOTES:: 7�4... or .00N,. a+•rt as - Se. M.. By Data Permit No jkik 04 vr %bp EXP I) SEAL DUCTS PER W.S.E.G. SECTION 14141 1 understand that the Plan Check approvals are subject to errors and omissions and approval of plans does not authorize the violation of any adopted code or ordinance. Receipt of con - tractor's copy of approved plans acknowledged. AUG 1 3 2003 N 3) INSULATE ALL SUPPLY d RETURN DUCTS TO COMPLY W/ Y4.S.E.G. TABLE 14 -5. 4) PROVIDE ECONOMIZER PER W.S.E.G. SECTION 1413 4 1433. #_ ti .. COPY GIP Of TAlvti JAN 15 2:;C3 r>� i i:U 4 DOS; • flfrill 2) INSTALL DUCT SMOKE DETECTOR TG COMPLY W/ U.M.G. SECTION 608. EPARATE PERMIT t REQUIRED FOR: r Vi7 CHANICAL 11-. 'EC TR IC AL he JMB1NG [ S PIPING CITY OF TUKWILA f3 EUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 1 3 2003 PERMIT CENTER NOTE: rule rooposALS, rs.wb srec ntic. moo• • mons ARe T1 sow Poo rsitTr Or rl1l?Oferira .! WATS. 1 AIR COIVITteolni . INC. (MAW MV AR; POR M GOI.Y mft k ar PNAG MD TIt i r r0 rL _ _ 0l� NlltlD ANY OISee4111ATKH Or Sxol MATe E I A Q[ AL PIo Olt3 n m AN ADOPTION. itannottAL OR GOtTAHr NTHOUT TIe PRIOR ►fMT1eN rallIWO4 Or MAC 5TR1CTL7 rotoolialTrO AIC SHALL ENTITLE rHAG TO IMASOIMeti,E computIATION PON "The rRN"ARATION Or SUCH MAT1S<iALS TOEWT1eR NTI ANY ofOSSSITIAL OR C eIOeWTWAW O4 Ofra4frarS Re!LLTme room sICH mesorroorobAna4 ALL ORNSIIR6 AH7 sreC.IrICAraws ARL" rRrumeweT cm AK, AR; , Sle.ecT TO COMEcTIOM, Artfp ENT AND SUrrtr INTATION Wort CST or WORK REVISIONS F'O Cm,e, %, :,Es SHALL BE MADE TO :c ?'E ^' ` WITHOUT PR 3R , 'JVAI. OF TUKW1LA BUILDING DIVIS131.'. ..T�: REVISIONS WILL RECURS A NEW PLAN SUBMITTAL =.±.) mAY 1W. :12I'TE Annt1: vx' j PLAN RrvI 'MI FEES. M03 -00 )I tif u W !— G DRAWN: MS ENGR: MS APPVD: JOB NUMBER: 4511D DATE: 13 JAN 03 M 1 SHEET 1 OF 1