HomeMy WebLinkAboutPermit M03-040 - SOUTHCENTER MALL - FRED MEYER JEWELERSFRED MEYER
JEWELERS
1119 SC MALL
M03 -040
z
re 2
B.
00
N LL`
W O,
N d.
Ili
Z F;
F— Oa
Z F—'
UJ Wu
U 0'
.O U'
0 I—
= U'
O
111 Z
U N:
O.
Z
r,
7
Parcel No.: 2623049023
Address: 1119 SOUTHCENTER MALL TUKW
Suite No:
Tenant:
Name:
Address:
Owner:
Name:
Address:
Contact Person:
Name:
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
SAM MILLER
Address: 8901 WILLOWS RD, REDMOND, WA
Contractor:
Name: UNIVERSAL MECHANICAL SERVICE
Address: PO BOX 2649, REDMOND WA
Contractor License No: UNIVEMS132JF
DESCRIPTION OF WORK:
ROOF TOP HVAC CHANGE -OUT; RELOCATE EXISTING T -STAT; REVISE EXISTING DUCT WORK
Value of Construction: $11,250.00
Type of Fire Protection:
Permit Center Authorized Signature:
FRED MEYER JEWELERS
1119 SOUTHCENTER MALL, TUKWILA, WA
hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not pre e to give authority to violate or cancel the provisions of any other state or local laws
regulating constr ctio or th perfor nce of work. I am authorized to sign and obtain this mechanical permit
3 7? 0
Signature:
Print Name:
doc: Mech
JG SOUTHCENTER LTD
25425 CENTER RIDGE RD, CLEVELAND OH
Wa
o� M c C rr /ti
MECHANICAL PERMIT
M03 -040
Permit Number:
Issue Date:
Permit Expires On:
Phone:
Phone: 425 885 -9100
Phone:
Expiration Date: 10 /30/2004
Fees Collected: $56.94
Uniform Mechnical Code Edition: 1997
Date:
Date:
M03 -040
03/17/2003
09/13/2003
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is
suspended or abandoned for a period of 180 days from the last inspection.
Printed: 03 -17 -2003
z
'~ w
00 N
U) ILI
J =
H
U)w
w 0
2
u-?
D. a
=
z1._
�
z I-
w
2 o
O • N
0H
w w
H -
• O
Z
w
• =
O
z
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
PERMIT CONDITIONS
Parcel No.: 2623049023 Permit Number: M03 -040
Address: 1119 SOUTHCENTER MALL TUKW Status: ISSUED
Suite No: Applied Date: 03/10/2003
Tenant: FRED MEYER JEWELERS Issue Date: 03/17/2003
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division.
3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be
inspected by that agency, including all gas piping (296- 4722).
4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical
work will be inspected by that agency (206- 835 - 1111).
5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any
construction. These documents are to be maintained and available until final inspection approval is granted.
6: Readily accessible access to roof mounted equipment is required.
7: Any exposed insulations backing material shall have a Flame Spread Rating of 25 or less, and material shall bear
identification showing the fire performance rating thereof.
8: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997
Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition).
9: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be
construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any
other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this
code shall be valid.
10: Manufacturers installation instructions required on site for the building inspectors review.
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws
regulating construction or the performance of work.
Signature:
Print Name: = "1 C v ^ C ' - o ,t.i
doc: Conditions
M03 -040
Date:
Printed: 03-17-2003
z
w
00
N
Co LU
J =
F-
U)
w O
g
(f) d
�w
z H
H
Z I-
w
w
0
0
❑ I-
w w
I-
LL O
..z
w
U =,
OH
z
Company Name:
Mailing Address:
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
Name: S (¢ 0''` / _ / L L. tr.! vt
Contact Person:
E -Mail Address:
Building Permit No
M echanical Permit; No. .Ot'
Public Works Permit No.
(For office use ^only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
Site Address: 6) 3 -.Cc u ` ( k , TP.• ,Dttl,, l
Tenant Name: Fit -.e rt T Yk
Property Owners Name: w (. S 7 F 4 c d C 14. ,0
Mailing Address: &A _L I / o ( w �► rr r 1
E -Mail Address: Vji e C, c o -
King Co Assessor's Tax No.:
Suite Number: C-3 B 8 Floor: ,--14-/A-'
WO. .�
City
New Tenant: 0 .... Yes El ..No
State
01 )&1 --
Zip
Day Telephone: 8 B .1 _ - '7./0 o
Mailing Address: g 0 / W 1< c. o %..r 5 G( K�y o v .i UJ .1 . 9 O' 3
City
State Zip
Fax Number: 88/ - 01 8 -
"„GENERAL;
tit= .r�•'� , ' t t
T ORINFORMATI OZ
Company Name: V / .5
Mailing Address: e y D ( L3 14 c ° t_rS ".10 nFv 0,_, u , 2 a 0..1 ^P
City
Contact Person: S V'''l / -r' a T Day Telephone: a 8 i - c7/ O o
E -Mail Address: 'A -Cm/ C C f K e cmn ry c c. C o -Fax Number: E3 B 1 - 6 9 e 9-
Contractor Registration Number: U N 1 Li r= /`1.' /3' Z - tf Expiration Date: / CV 7 Vo 2
* *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance **
State Zip
ARCHITECT,,OF:'REC. . Alll'plans must be wet stamped by of Record;;
t ..... i7 ! s..F 1. S , 5 .�'...- � ? .. .k. �tF:J .. .. 'i� ... .. ..� _l�. .. .. .. ...� ... ' 1' � a.;•~ .
State
Zip
City
Day Telephone:
Fax Number:
ENGINEER OF RECORD All pians: must be:wet stamped b E ngineer o[Recor
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
tappliationslpennit application (1.2003)
1/2003
Page 1
State
Zip
'ji",.44 i +`a R1' F I' 1 S +i�:•4 - Y .,.151.. - *�i. �, +ii : . ..." • tid.v+.
Z
W
UO
U 0
J =
H
U) Lt.
WO
g
I d
= w
H =
Z �
t- 0
Z F—
W
W
U �
O N
c t-
w
H1-
w z
W
=
O~
Z
on f?lle (Mactor's bid price): $
Scope of Work (please provide detailed information):
Will there be new rack storage? ❑...Yes ❑ .. No If "yes ", see Handout No.
Existing Building Valuation: $
for requirements.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inchcs)
For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑...Yes ❑ .. No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ .. Sprinklers ❑...Automatic Fire Alarm ❑...None 0.. Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes 0... No
If "yes", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets.
UTILITY DISTRICTS:
Note: If the utility district is not City of Tukwila, you must provide written verification and approval from that utility district at the time of permit
application.
Water
❑ .. City of Tukwila Water District ❑.. Water District 1/125 ❑... Highline Water District ❑...City of Renton Water District
Sewer
❑ .. City of Tukwila Sewer District ❑.. Val Vue Sewer District ❑...City of Renton Sewer District ❑...City of Seattle Sewer District
❑ .. Septic System (If property is served by a septic system, 2 copies of approved septic design from King County Health Department must be
submitted at the time of permit application)
'application' crrnit application (1.2003)
Page 2
..,..t ... . _ _....... ...:a...w....a.: i.: •Sl..;t'
Existing
Interior
Remodel
Addition to
Existing
Structure
New
Type of
C onstruction
per UBC
Type of
Occupancy per
UBC
l" Floor
2n.° Floor
3' Floor •
Floors thru
Basement
Accessory ; Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport .. .
Covered Deck
Uncovered Deck
on f?lle (Mactor's bid price): $
Scope of Work (please provide detailed information):
Will there be new rack storage? ❑...Yes ❑ .. No If "yes ", see Handout No.
Existing Building Valuation: $
for requirements.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inchcs)
For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑...Yes ❑ .. No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ .. Sprinklers ❑...Automatic Fire Alarm ❑...None 0.. Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes 0... No
If "yes", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets.
UTILITY DISTRICTS:
Note: If the utility district is not City of Tukwila, you must provide written verification and approval from that utility district at the time of permit
application.
Water
❑ .. City of Tukwila Water District ❑.. Water District 1/125 ❑... Highline Water District ❑...City of Renton Water District
Sewer
❑ .. City of Tukwila Sewer District ❑.. Val Vue Sewer District ❑...City of Renton Sewer District ❑...City of Seattle Sewer District
❑ .. Septic System (If property is served by a septic system, 2 copies of approved septic design from King County Health Department must be
submitted at the time of permit application)
'application' crrnit application (1.2003)
Page 2
..,..t ... . _ _....... ...:a...w....a.: i.: •Sl..;t'
PUBL ;WORKS �P, ERMITI I -: 206.433017
Scope of Work (please provide detailed information):
Street Use:
❑ .. Street Use
Land Altering and /or Hauling:
❑.. Land Altering: ❑...Cut cubic yards ❑...Fill
Storm Drainage:
❑ .. Storm Drainage 0- ..Flood Control Zone
Sewer Information:
❑ .. City of Tukwila Sewer District ❑ .. Val Vue Sewer District ❑...City of Renton Sewer District ❑ ..City of Seattle Sewer District
❑ .. Sanitary Side Sewer ❑.. Sewer Main Extension ❑ ..Private ❑ .. Public
Water Information:
❑.. City of Tukwila Water District ❑ .. Water District # 125 ❑..- Highline Water District ❑...City of Renton Water District
❑ .. Water Main Extension 0.. Private ❑...Public
❑ .. Water Meter/Exempt: Size(s): ❑ -. Deduct ❑...Water Only
❑ .. Water Meter Permanent #: Size(s):
❑ .. Water Meter Temporary #: Size(s): ❑ .. Est. Quantity: gallons
❑ .. Fire Loop/Hydrant (main to vault) #: Size(s): ❑ .. Landscaping Irrigation
❑ .. Miscellaneous:
Monthly Service Billing to:
Name: Day Telephone:
Mailing Address:
City State Zip
Water ... ❑ Sewer ... ❑ Sewage Treatment ❑ Fire Line ....
Water Meter Refund/Billing:
Name:
Mailing Address:
\applications \permit application (1-2003)
Please refer to Public: Works Bulletin #1 for fees and estimate sheet.
❑ -.. Channelization /Striping
CaII before you Dig: 1- 800 - 424 -5555
❑...Curb cut/Access/Sidewalk
City
cubic yards ❑ Hauling
Day Telephone:
State Zip
1s . , • •. 0. '4/,
Unit Type:
Qty
Unit Type:
Qty
Unit Type:
Qty
Qty
Furnace <100K BTU
Air Handling Unit
>= 10,000 CFM
Other Mechanical
Equipment
0 -3 HP /100,000 BTU
Furnace >100K BTU
Evaporator Cooler
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan
15 -30 HP/I,000,000 BTU
Suspended/Wall/Floor
Mounted Heater
Ventilation System
30 -50 HP /1,750,000 BTU
Appliance Vent
Hood
50+ HP /1,750,000 BTU
Heat/Refrig/Cooling
System
Incinerator - Domestic
Air Handling Unit
< =10,000 CFM
Incinerator — Comm/Ind
MECHANICAL CONTRACTOR INFORMATION
/
Company Name:
Mailing Address:
Contact Person: s (4( " A
E -Mail Address:
Contractor Registration Number: U et-) R.) T.S / ? e - Expiration Date: 7 t /J a/ o 3
* *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance **
Valuation of Project (contractor's bid price): $ / / e J -0 . 0
Scope of Work (please provide detailed information): go6 0 (-/U 1.0 ( ,'/.- ,../c g C7.., /^
A 1- o c. a r ez. 1 X t 3 %/ ^ f s TAT J ,ems c) is d= �Gc is7 e LI c
Use: Residential: New .... p Replacement .... ❑
Commercial: New .... ❑ Replacement ....O.
Fuel Type: Electric ❑ Gas ....K Other:
Indicate type of mechanical work being installed and the quantity below:
`.PERMIT; APPLICATIQN 10TO :-
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as
defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING O
Signature:
Print Name:
\applications'permit application (1.2003)
1/2003
u .1
a A H i • ZED AGENT:
L..,t 1 L Law S
_a -o
KGel
4%.6 G a d L.., $ X
City State Zip
Day Telephone: g 8 S
S81 -- 698-
Fax Number:
Date: 3/
— �.-= ,"-1 C C v ?` 1 F /V ' Day Telephone: le 1 ' ' 8 8 I' T/' 0
Mailing Address: cl 0 ( W / L L d tf Qb
City State Zip
Date ApplicatiAccepte
I/
1 Date Application Expires:
I�
Staff I ',�,
1
Page 4
RECEIPT
re al
Parcel No.: 2623049023 Permit Number: M03 -040 6 v
Address: 1119 SOUTHCENTER MALL TUKW Status: APPROVED v O
Suite No: Applied Date: 03/10/2003 CO CO w,
Applicant: FRED MEYER JEWELERS Issue Date: tu H
N w :
w O
Receipt No.: R03 -00330 Payment Amount: 56.94 g Q
Initials: BLH Payment Date: 03/17/2003 12:46 PM = Cy
User ID: ADMIN Balance: $0.00 Z H
Z O
CU
Payee: UNIVERSAL MECHNICAL SERVICE CO INC D C
U co
O --
0 I—
w ui
TRANSACTION LIST:
Type Method Description Amount I 0
IL
Payment Check 026828 56.94 Z
w
0—
I.
0
z
ACCOUNT ITEM LIST:
Description
doc: Receipt
City of Tukwila
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
MECHANICAL - NONRES
PLAN CHECK - NONRES
Account Code Current Pmts
000/322.100 45.55
000/345.830 11.39
Total: 56.94
Printed: 03 -17 -2003
P je ct: re
- f M -
Type of Inspection:
`�f i ou< T es - I - �C}
Cal •:
' 3 s /,�o3
irecy: is
lcsd Date
Specia Instructions:
_
, +. ( I
5
(e i 1e f- . Bt
Date Wan
if • 73 /(03
Requ e ste /
C.--
Phone N -20 - 0 9 01 - 0 7 07 / 0
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
r1
T •
b •) • 31 -3670
Approved per applicable codes. El Corrections required prior to approval.
COMMENTS:
cak F;
Date J z
$47.00 REINSPECTId J FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
P.:Inject:
. e .0A ,e,,,
Type of Inspection:
/L
Address: 1
.
1 / 9 S. C 040( 1
/
Date Called:
L-0/7/63
Date Wanted: I a.
W*03 crS.
(
Spec al Instructions:
-t pm
Reques4
JD/ 4 1 4 Se )
Phon
/7 1 r
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
El Approved per applicable codes. --faCorrections required prior to approval.
COMMENTS:
igAPL9--C
544 S VA - 1-t-r -
nspe
IRec
t No.:
INSPECTION RECORD
Retain a copy with permit
Date: ) 0.5
$47 1 I REINSPECTION FEE QUIRED. Pr or to Inspection, fee must be
pale at 6300 Southcenter Blvd., uite 100. all to schedule reinspection.
Co.—Jr:L.4
Date:
PERM
(206)431-3670
cw
..•
IMINSOMMMESSINIMINOSSW
.1
Proj7 t: ,-
Type o f Inspection: .
Address:
//,% ...r %a
Date Called: o
-2o -O3
_
Special Instructions:
Date Wanted:
m
p. .
Requester: •
>,C
Phone No:
INSPECTION NO.
El Approved per applicable codes.
INSPECTION RECORD
Retain a copy with permit
PERMIT
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 �� (206)431 -3670
Corrections required prior to approval.
COMMENTS:
t
'1 (kg, C l9-/v:,7 Q_Nu3
• c7 ks - A...R e i u
Date:
Z.1 — v 3
.00 REINSPECTION FE REQUIRED. Priito Inspection, fee must be
id at 6300 Southcenter Blvd., Suite 100. II to schedule reinspection.
Receipt No.:
(Date:
z
6 U
00 0
W H
(0 w
w
LL Q
N 3
-a
I - w
Z �
Zo
W
2 Q.
0
0 —
0 I—
w W
I-
W Z
0
0
z
Prot:
j __A ifri
r err"
Type of Ins ection:
A ss
i 4 1 S i( ••pla.it •
Date Calle :
ri (
1 1 6/03
Sp dal Instructions:
i t ' eiLit
Date Wanted:
e i ,,,Ic 5 crr i,-.•
Requester: j i i
it I
-
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
'Inspect
INSPECTION RECORD
Retain a copy with permit
Date:
PERMIT
(206)431-3670
Co rec i n requ ed prior to approval.
-414.30 (087
El Approved per applicable codes.
COMMENTS:
0„), . r) YIP GU
UNA oc( u rrr\ wcU
c)lt■ _ oci- co 1 , 1 4 e
Q )flV 1
y-,
SI Inox
'Date:
0
$47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
'Receipt No.:
Prscs:
} iiiPt/e-wS Jew&
Type al Inspection:
F/i1M-L._ - it/ 8
ess:
Ad
if SC /44/ILL
Date Called:
-/ — 23
Special Instructions:
Date Wa ted: , a.m.
V -03 p.m •
(
Request er:
\---
W1VN C°
Pho No:
/: ) 'Cl V
• .. • ' • . • • • • .
• •
•
COMMENTS:
Insp tor:
4
Rec pt No.:
Date:
INSPEC ION NO. INSPECTION RECORD
Retain a copy with permit In t-13- 3 5 /
PERMI
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (216)431-3670
D . Approved per applicable codes. igCorrections required prior to approval.
Date: /
4 // 7-t f /'
S4 .00 REINSPECTION FEE REQUIRED. rior to inspection, fee must be
p d at 6300 Southcenter Blvd., Suite 10 . Call to schedule reinspection.
COMMENTS:
CD c - ----,,,Ai)442_ 1,..,4.__L
Ad
,C, . 040,, (
Date Called 1
f 03
:,-, _V--)c, 6- j17.(421,e_ a r)--,,
ctions:
Rm 14/01.47
•
a\
1,-Q C O c.,\A- 0e d,,
LJL' (1,(>9 7-CodulA -
Requestl_ \ -1- ) i6t.i,(7
Phone 4;
/ A q 9_ --- 2 ( 1 L I °
—--d*
-A-._R - ( "._) ('& z--; "
-
÷ i,i,
c - N . rA _ A r k 0. , k D
p ri t eit 64 CleA 4k,u)
Type ofellp,ection:
•• 1 kg. - 1 L
esI
Ad
,C, . 040,, (
Date Called 1
f 03
Special lnst
t---__
ctions:
Rm 14/01.47
•
a\
Date Wontedly t.,., I ,
1 I
•Ti.
Requestl_ \ -1- ) i6t.i,(7
Phone 4;
/ A q 9_ --- 2 ( 1 L I °
INSPECTION RECORD
Retain a copy with permit
INSPE •N NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
(206)431-3670
Approved per applicable codes.
Corrections required prior to approval.
Date: /
1- 7 / /2- 4 b"
7.00 REINSPECTIO14 FEE REQUIRED. P ior to inspection, fee must be
aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
•
ACTIVITY NUMBER: M03 -040 DATE: 03 -10 -03
PROJECT NAME: FRED MEYER'S JEWELERS
SITE ADDRESS: 1119 SOUTHCENTER MALL
X Original Plan Submittal Response to Incomplete Letter #_
Response to Correction Letter # Revision # After Permit Is Issued
DEPARTMENTS:
Building Division
Public Works
PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
,4'l 7 rtiL 3 -(a-O3
Fire Prevention �
Structural ❑
Planning Division
Permit Coordinator
;Lie
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 03 -11 -03
Complete d Incomplete ❑
Comments:
Not Applicable ❑
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROyTING:
Please Route I Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions iszr Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28 -02
PERMIT COORD COPY
DUE DATE: 04 -08 -03
DATE:
. ,
REGI STERED AS :PROVIDED ,BY:. LAV
CONST CONT SPECIALTY •
t '7 REGIST # EXP DATE
CCAAAIT UNIVEMS132JF
EFFECTIVE . .DATE 04/ p 61 i.9 pvt
UNIVERSAIS MECH SERi/ICE: COINC
PO BOX 2649 -
Signature ://,7b
'=2,946.,
REDMOND
Issued by DEPARTMENT OF LABOR AND.1NDUSTRIES
_... -. �. . -_ __ ` �_
l.A' W .+F^gk : i. : aafCY d Fit A* 1 PAM
t ',Le_ ',Kw Ear a,s• _'.r ' S'rt. WI
i -- - v - -- •► - - . T
.q. E - 1 ORPtiYiE,
a_ r , .E ', A` - 7, 94.1 EG ,, et_ Ace u• - as i 2
_
t: • , irf:,E
€ r PL,
=•
A _ fit:
F I + a Tit
RE T: a ►• NO!E! ! M.1 _ .�
4, 11 L 24. 4
Ft, I , OPLIEGIR
a
R - EGLS 1±
'E C • (NEP Sou. _: A%+ VAN, c AC �')Rf RS Tt"JS FRfCE_ AR * V'';• AL
STEEL ELWA
ORA
LENG'^
RouNC TE '
EXTENSION N
0.B D
( Dr1
L) ROOF CURB
SMCr.E DETECTOR
TURNING JANE'-
tJ.
M.'.
MODEL
SERIAL
VOLTAGE _ -- --
FAN
R P.M ____
4 h:'•E1' is1:1!EL 9EAt* Y .'.W "E,.
A� A=
j N•"'TE
RE' _Rt. 'D i *JP. =,q. -,k 1 12112 35 •
i - r -- - - --r
p` 1 A =• ! NE � ` E 1
1 ►�:� �ET'JRN 1 i � .�.
HAw.,E
NG'M
24 X 24 Lk- ANEL
SUPPLY
FLEXIBLE CONNE TION
MCT IR
H (- VIA -
AM R'•_ RPM _
,- DIFFuSEF
14•• MIN - -
I
A -2,!` ;♦ t - TIN',
ANC ^� (rx•'EP
SE: _ A
DRAW A,..
LAY -IN DIFFUSER DETAIL
ROOPTOF AC UNIT
CUT RE` .iRN - )PEN N - AT 45 DEC OPEN UP
Dircust R ____ ROGM TEMP =v
C.F.M ; :ACH) ___._ 0. A. TEMP ° F
PE _ STEP AV DOT, SEP S a -EDuiE
4
NO, ',aA-
24 x 24 .A' -;N PANEL
NECK ,'D_ -
- -
. :IMENSIi , N SHOWN ON MECR PLAN
DUCT /NECK SIZE
RETURN
PVC CONDENSATE DRAIN W, CLEANDUT, 4 DEEP. TO SPLASH BLOCK
INSJLATION UN INC IN RETURN AIR DUCTWORK INDICATED SIZE IS NET INSIDE
-- C.F
ROOFTOP A.C..U. A R E3ALAN -E DATA
THIS FORM TO BF PHC)Tn- COPIED. COMPLETED BY THE AIR BALANCE TRADE
AND SUBMI'TI D WITH THE AIR BALANCE PEPOPT
1,4:444,114
s. -VIOL ,
35 At- ?
S1
1 EE_
E B
.�
-- 1
4.4 35 DOVER M* *E I STEEL
- - -
35
35 oo11ER n►, TE
DUCT SYSTEM
A:. P:ETURN AIR AN
SUPP! DLICTWDDK
EXHAU "T A,R
NUTS ALL _',11ES ARE A!RWAr DIME'S IONS
4 rAIN
c x
SPLASH
GA :.ONNECTDN w TH UNION. PR TO 7•' W U.L. LIST E.:: BALL VALVE AND DIRTLEG.
__CF
Fl1r �1+�Y Fi�A. - 4En&k..c
ALUM *. _1,0
v# ALUMMY.M
STEEL
STEEL
DUCTWORK SCHEDULE
SPA NA SMA NA
I PRESSURE SEAL
CLASS .,LASS
2" A
2" B
ROOF
PEOPLE
LIGHTING
',CSC LOADS
CASH REG
TRANSFORMER
WATER HEATER
RECEPTACLES
VENTILATION
RESH AIR
FAN MOTORS
HEAT GAIN
TOTALS
SAFETY FACTOR
UNIT SELECTION
TAG
EF
SEF
0
0
4E> S►Z,E
,.
MANt!FACTURFR
& MODEL NUMBER
GREENHECK
216
GREENHECK
G -160 -B
GALVANIZED
STEEL
GALVAN +_'E D
STEEL
ELBOW Wj DBL THICKNESS TURNING VANE
FRED MEYER JEWELER
South Center Mau Seattle Tuckweila Wa
BUILDING FACTORS
ROO.' BUt-RIDGID INSUL +MTL DECK'.
WALL FUR, GYP
NUMBER
10
WATT_.
8000
WATT;
150
30000
1500
2400
TOTAL AREA
1,530
HEATING
1. 20
OUT AIR
0.1 1
0.17
LENGTH
51.00
% LOSS
0.50
0.05
0.10
0.25
COOLING
11 �
NOMINAL
TONNAGE
00
6 25
750
AREA SERVICE.
SERVCC
JEWEI f R'S EXHAUST
ROOM
ENTIRE SMOKE
STORE EXHAUST
RC
AREA W ; 50 FT
1,530 5.23
NET WATTS
75
1500
150
600
TOT CAP
AT 95 CONE
60.000
75,000
90,00C
100
2300
CFM ESP
.25
0.25
WIDTH AREA
COMPONENT FACTORS
0.33 1 0
1.75 1 0.41
30.00 1530 19.00 0.053
FAN SCHEDULE
MOTOR HP FAN WEIGHT REMARK,
& VOLTAGE TYPE t,LBS)
53 WATTS
120 V
1/3
120 V
IJ 3
R U
RE - WFGRRCEE ! --4
INSIDE AIR
0.62
0.67
ELEVATION
100
R VALUE
19.00
400
HTG dT
5
CFM / SO FT TOTAL CFM
0.30 459
UNITS REO
1.00
SENSIBLE
RATIO
0.75
0.75
0.75
BHP / UNIT
1.00
IREVISIONS
rl,s 1 f = SHALL BE MADE TO
-
;JF WORK WITHOUT PRIOR
OF ;''.y(W1LA BUILDING DIV1S1Ot'
WILL REOUIRE A P PLAN S. AL
•, 4 R MAY INCLUDE
�N� MAY 1NCLL� � `�. PLAN
BTU / SO FT HEAT LOSS
2.68 4,107
HTG DT
TOTAL HP
1.00
ADJUSTED
SEN CAP
45,000
56,250
67,500
HEATING
i (_)SS
30.816
77,051
NUMBER OF
UNIT . REOUIRED
1.19
0.95
0.79
X 0 .-to"
P
n •
JCT
i 1R
A ±z O1-
10' •o DA t_' - .
f1 -
W!NT RM TEMP SUM RM TEMP SUM '.% db SUM 1% wb
72 75 84 68
COOLING dT
65
BTU /
3.414
3.414
3.414
3.414
LOSS COOLING DT (DT + 5) x GAIN
- 5 deg SPC WT AIR DTxSWAxCFM
54 26, 14 15.12 6.940
SENS CAP
0
56,250
0
56,250
w
PROVIDE, FOR WIRING BY E.C., SOLID STATE WAL, . SPEED SWITCH
WINTER 99%
21
BTU EACH
315
BTU / WATT
3.41
TOTAL
TONNAGE
0.00
6.25
0.00
6.25
UNIT EQUIPED WITH INTEGRAL CEILING GRILLE & BACKDRAFT DAMPER
1530 SO FT x 1.5 CFM,''SO = 2300 CFM
PROVIDE ROOF CURB, MOTORIZED BACKDRAFT DAMPER,
I COI
B; _)5C •
10 "0 DUoT
. ( 0124x121
. I -(.s -
� 10.12.
I. 10x;
i
// 10 `° L T
BTU , HP
3000
BIRIJSCRELN
_EPARAT PERMIT
REQUIRED FOR:
E», '.1ECHANICAL
; ye._ i. .ECTRICAL
JMBING
• )AS PIPING
CITY OF TUKWILA
L 1 111 ! ■ ^ n1vlelnu
24.2 TPANSF1- P-- r
t . PEN'N AE CEIL_iNO
Y
THERMOSTAT
5' -6"
{A'
...- .i_,_1if( :1:1' I . • t I r j• F I 1
c 15
12/11/02
BTU / FT HEAT GAIN
3.42 5,234
3,150
27,312
256
5121
512
2048
COOLING
GAIN
53,574
58,931
SQUARE FT
PER TON
By
Date
Permit No
EF
{A.
RG 24x
/
I understand that the Plan Check approvats are
subject to errors and om'ss:ons and approval of
plans does not authorize the violation of any
adopted code or ordinance. Receipt of con-
t copy of approved clans acknowledged.
- 4- - 4
MECHANICAL PLAN
1/4' = I ' -O °
ACU SCHEDULE
ACU - AIR CONDITIONING UNIT - 6.25 TON NOM.
TRANE MODEL YCD - 07S GAS ;/ ELECTRIC UNIT
TOTAL COOLING CAPACITY 75.0 MBH
SENSIBLE COOLING CAPACITY 56.25 MBH
AT 95 F EDB AND 67 F EWB.
HEATING CAPACITY 120 CFH IN / 97,000 BTU /HR U • IT
2400 CFM SUPPLY AIR AT 0.80" ESP, 980 RPM.
300 CFM OUTSIDE AIR, 2.0 H.P. EvAP FAN (OVERSIZE'.
208/3/60, 39.5 MCA, 60 MOCP
CPERATING WEIGHT 96i.i LEIS
WITH ECONOMISER, POWER EXHAUST, ROOF CURB,
GENERAL NOTES:
1. ARRANGE THE FINAL NSPECTIONS BY THE BUILDING AUTHORITIES.
Z. VERIFY VOLTAGES WIT 1 ELECTRICAL CONTRACTOR PRIOR TO ORDERING
OF ANY AND ALL ME 2HANICAL EQUIPMENT.
3 VERIFY EXISTING CONDITIONS INCLUDING UTILITIES AND LOCATIONS
OF PIPE, CONDUIT, L JCTWORK. ETC. PRIOR TO SUBMITTING BID.
3000 IN THE FvENT A DISCREPANCY IS FOUND IN THE CON
DOCUMENTS, NOTIFY 'HE ARCHITECT AND LANDLORD /4 ONCE
4 KEEP PIPING AND DUCTWORK FREE FROM CONTACT WITH
OR EQUIPMENT TO PREVENT NOISE TRANSMISSION
AND ALLOWING FOR C._EARANCE FOR EXPANSION \ND CONTRACTION
5 FURNISH BALANCE REPORT TO LANDLORD, ARCHITECT /ENGINEER
PRIOR IQ OPENING.
245 .5vv> a1e or off V Wired.
PO,OF JACK.
A 7 00
F.,0 DUCT
L NDE RCUT
['COP
L 50
8 "a DUCT
'1
I A R - 1
RECE!"ED
CITY OF TI 11(WILA
MAR 1 0 2003
PERMIT CENTER
724 MARION BUILDING
1276 WEST THIRD STREET
CLEVELAND, OHIO 44113
TELEPHONE 216 - 771 -1121
FAX 216- 696 -3545
e - moil proppeOproppe rom
PAUL COLTON & ASSOCIATFS
CONSULTING ENGINEERS
lvEi3•-q"
as 14 . ' 's s• se* +c• r- y.••
O' •-e-t; 4 - A•_w:•�•a ` ^! as•
ate 11 :e
LTE 1c3UE
'. '17/02 31C PERUf'
18/03 REr
as
raver' E. RCP DAF
HERSCNMAN
ARCHITECTS
'N
z
O
1 H-
Q
cc co
W Q
Z
O J
LL
0 w -
u 0
2 3 6 2 5
COMMERCE PARK
CI_EVEL AND OHIO
4 4 1 2 2
PHONE 2'6. 464 -4
FAX 21b - 464 0592
[-MAIL real box,T1
MP -2
MECHANICAL LEGEND
SYMRL
DESCRIPTION
SA
SUPPLY AiR
Cr
T
GENEAL CONTRACTOR
C)
I
7 DRAY PROGRAMAgLE THERMOSTAT
FLEXIBLE DUCT (4 MAX LENGTH I
MANUAL VOLUME DAMPER
_... -. �. . -_ __ ` �_
l.A' W .+F^gk : i. : aafCY d Fit A* 1 PAM
t ',Le_ ',Kw Ear a,s• _'.r ' S'rt. WI
i -- - v - -- •► - - . T
.q. E - 1 ORPtiYiE,
a_ r , .E ', A` - 7, 94.1 EG ,, et_ Ace u• - as i 2
_
t: • , irf:,E
€ r PL,
=•
A _ fit:
F I + a Tit
RE T: a ►• NO!E! ! M.1 _ .�
4, 11 L 24. 4
Ft, I , OPLIEGIR
a
R - EGLS 1±
'E C • (NEP Sou. _: A%+ VAN, c AC �')Rf RS Tt"JS FRfCE_ AR * V'';• AL
STEEL ELWA
ORA
LENG'^
RouNC TE '
EXTENSION N
0.B D
( Dr1
L) ROOF CURB
SMCr.E DETECTOR
TURNING JANE'-
tJ.
M.'.
MODEL
SERIAL
VOLTAGE _ -- --
FAN
R P.M ____
4 h:'•E1' is1:1!EL 9EAt* Y .'.W "E,.
A� A=
j N•"'TE
RE' _Rt. 'D i *JP. =,q. -,k 1 12112 35 •
i - r -- - - --r
p` 1 A =• ! NE � ` E 1
1 ►�:� �ET'JRN 1 i � .�.
HAw.,E
NG'M
24 X 24 Lk- ANEL
SUPPLY
FLEXIBLE CONNE TION
MCT IR
H (- VIA -
AM R'•_ RPM _
,- DIFFuSEF
14•• MIN - -
I
A -2,!` ;♦ t - TIN',
ANC ^� (rx•'EP
SE: _ A
DRAW A,..
LAY -IN DIFFUSER DETAIL
ROOPTOF AC UNIT
CUT RE` .iRN - )PEN N - AT 45 DEC OPEN UP
Dircust R ____ ROGM TEMP =v
C.F.M ; :ACH) ___._ 0. A. TEMP ° F
PE _ STEP AV DOT, SEP S a -EDuiE
4
NO, ',aA-
24 x 24 .A' -;N PANEL
NECK ,'D_ -
- -
. :IMENSIi , N SHOWN ON MECR PLAN
DUCT /NECK SIZE
RETURN
PVC CONDENSATE DRAIN W, CLEANDUT, 4 DEEP. TO SPLASH BLOCK
INSJLATION UN INC IN RETURN AIR DUCTWORK INDICATED SIZE IS NET INSIDE
-- C.F
ROOFTOP A.C..U. A R E3ALAN -E DATA
THIS FORM TO BF PHC)Tn- COPIED. COMPLETED BY THE AIR BALANCE TRADE
AND SUBMI'TI D WITH THE AIR BALANCE PEPOPT
1,4:444,114
s. -VIOL ,
35 At- ?
S1
1 EE_
E B
.�
-- 1
4.4 35 DOVER M* *E I STEEL
- - -
35
35 oo11ER n►, TE
DUCT SYSTEM
A:. P:ETURN AIR AN
SUPP! DLICTWDDK
EXHAU "T A,R
NUTS ALL _',11ES ARE A!RWAr DIME'S IONS
4 rAIN
c x
SPLASH
GA :.ONNECTDN w TH UNION. PR TO 7•' W U.L. LIST E.:: BALL VALVE AND DIRTLEG.
__CF
Fl1r �1+�Y Fi�A. - 4En&k..c
ALUM *. _1,0
v# ALUMMY.M
STEEL
STEEL
DUCTWORK SCHEDULE
SPA NA SMA NA
I PRESSURE SEAL
CLASS .,LASS
2" A
2" B
ROOF
PEOPLE
LIGHTING
',CSC LOADS
CASH REG
TRANSFORMER
WATER HEATER
RECEPTACLES
VENTILATION
RESH AIR
FAN MOTORS
HEAT GAIN
TOTALS
SAFETY FACTOR
UNIT SELECTION
TAG
EF
SEF
0
0
4E> S►Z,E
,.
MANt!FACTURFR
& MODEL NUMBER
GREENHECK
216
GREENHECK
G -160 -B
GALVANIZED
STEEL
GALVAN +_'E D
STEEL
ELBOW Wj DBL THICKNESS TURNING VANE
FRED MEYER JEWELER
South Center Mau Seattle Tuckweila Wa
BUILDING FACTORS
ROO.' BUt-RIDGID INSUL +MTL DECK'.
WALL FUR, GYP
NUMBER
10
WATT_.
8000
WATT;
150
30000
1500
2400
TOTAL AREA
1,530
HEATING
1. 20
OUT AIR
0.1 1
0.17
LENGTH
51.00
% LOSS
0.50
0.05
0.10
0.25
COOLING
11 �
NOMINAL
TONNAGE
00
6 25
750
AREA SERVICE.
SERVCC
JEWEI f R'S EXHAUST
ROOM
ENTIRE SMOKE
STORE EXHAUST
RC
AREA W ; 50 FT
1,530 5.23
NET WATTS
75
1500
150
600
TOT CAP
AT 95 CONE
60.000
75,000
90,00C
100
2300
CFM ESP
.25
0.25
WIDTH AREA
COMPONENT FACTORS
0.33 1 0
1.75 1 0.41
30.00 1530 19.00 0.053
FAN SCHEDULE
MOTOR HP FAN WEIGHT REMARK,
& VOLTAGE TYPE t,LBS)
53 WATTS
120 V
1/3
120 V
IJ 3
R U
RE - WFGRRCEE ! --4
INSIDE AIR
0.62
0.67
ELEVATION
100
R VALUE
19.00
400
HTG dT
5
CFM / SO FT TOTAL CFM
0.30 459
UNITS REO
1.00
SENSIBLE
RATIO
0.75
0.75
0.75
BHP / UNIT
1.00
IREVISIONS
rl,s 1 f = SHALL BE MADE TO
-
;JF WORK WITHOUT PRIOR
OF ;''.y(W1LA BUILDING DIV1S1Ot'
WILL REOUIRE A P PLAN S. AL
•, 4 R MAY INCLUDE
�N� MAY 1NCLL� � `�. PLAN
BTU / SO FT HEAT LOSS
2.68 4,107
HTG DT
TOTAL HP
1.00
ADJUSTED
SEN CAP
45,000
56,250
67,500
HEATING
i (_)SS
30.816
77,051
NUMBER OF
UNIT . REOUIRED
1.19
0.95
0.79
X 0 .-to"
P
n •
JCT
i 1R
A ±z O1-
10' •o DA t_' - .
f1 -
W!NT RM TEMP SUM RM TEMP SUM '.% db SUM 1% wb
72 75 84 68
COOLING dT
65
BTU /
3.414
3.414
3.414
3.414
LOSS COOLING DT (DT + 5) x GAIN
- 5 deg SPC WT AIR DTxSWAxCFM
54 26, 14 15.12 6.940
SENS CAP
0
56,250
0
56,250
w
PROVIDE, FOR WIRING BY E.C., SOLID STATE WAL, . SPEED SWITCH
WINTER 99%
21
BTU EACH
315
BTU / WATT
3.41
TOTAL
TONNAGE
0.00
6.25
0.00
6.25
UNIT EQUIPED WITH INTEGRAL CEILING GRILLE & BACKDRAFT DAMPER
1530 SO FT x 1.5 CFM,''SO = 2300 CFM
PROVIDE ROOF CURB, MOTORIZED BACKDRAFT DAMPER,
I COI
B; _)5C •
10 "0 DUoT
. ( 0124x121
. I -(.s -
� 10.12.
I. 10x;
i
// 10 `° L T
BTU , HP
3000
BIRIJSCRELN
_EPARAT PERMIT
REQUIRED FOR:
E», '.1ECHANICAL
; ye._ i. .ECTRICAL
JMBING
• )AS PIPING
CITY OF TUKWILA
L 1 111 ! ■ ^ n1vlelnu
24.2 TPANSF1- P-- r
t . PEN'N AE CEIL_iNO
Y
THERMOSTAT
5' -6"
{A'
...- .i_,_1if( :1:1' I . • t I r j• F I 1
c 15
12/11/02
BTU / FT HEAT GAIN
3.42 5,234
3,150
27,312
256
5121
512
2048
COOLING
GAIN
53,574
58,931
SQUARE FT
PER TON
By
Date
Permit No
EF
{A.
RG 24x
/
I understand that the Plan Check approvats are
subject to errors and om'ss:ons and approval of
plans does not authorize the violation of any
adopted code or ordinance. Receipt of con-
t copy of approved clans acknowledged.
- 4- - 4
MECHANICAL PLAN
1/4' = I ' -O °
ACU SCHEDULE
ACU - AIR CONDITIONING UNIT - 6.25 TON NOM.
TRANE MODEL YCD - 07S GAS ;/ ELECTRIC UNIT
TOTAL COOLING CAPACITY 75.0 MBH
SENSIBLE COOLING CAPACITY 56.25 MBH
AT 95 F EDB AND 67 F EWB.
HEATING CAPACITY 120 CFH IN / 97,000 BTU /HR U • IT
2400 CFM SUPPLY AIR AT 0.80" ESP, 980 RPM.
300 CFM OUTSIDE AIR, 2.0 H.P. EvAP FAN (OVERSIZE'.
208/3/60, 39.5 MCA, 60 MOCP
CPERATING WEIGHT 96i.i LEIS
WITH ECONOMISER, POWER EXHAUST, ROOF CURB,
GENERAL NOTES:
1. ARRANGE THE FINAL NSPECTIONS BY THE BUILDING AUTHORITIES.
Z. VERIFY VOLTAGES WIT 1 ELECTRICAL CONTRACTOR PRIOR TO ORDERING
OF ANY AND ALL ME 2HANICAL EQUIPMENT.
3 VERIFY EXISTING CONDITIONS INCLUDING UTILITIES AND LOCATIONS
OF PIPE, CONDUIT, L JCTWORK. ETC. PRIOR TO SUBMITTING BID.
3000 IN THE FvENT A DISCREPANCY IS FOUND IN THE CON
DOCUMENTS, NOTIFY 'HE ARCHITECT AND LANDLORD /4 ONCE
4 KEEP PIPING AND DUCTWORK FREE FROM CONTACT WITH
OR EQUIPMENT TO PREVENT NOISE TRANSMISSION
AND ALLOWING FOR C._EARANCE FOR EXPANSION \ND CONTRACTION
5 FURNISH BALANCE REPORT TO LANDLORD, ARCHITECT /ENGINEER
PRIOR IQ OPENING.
245 .5vv> a1e or off V Wired.
PO,OF JACK.
A 7 00
F.,0 DUCT
L NDE RCUT
['COP
L 50
8 "a DUCT
'1
I A R - 1
RECE!"ED
CITY OF TI 11(WILA
MAR 1 0 2003
PERMIT CENTER
724 MARION BUILDING
1276 WEST THIRD STREET
CLEVELAND, OHIO 44113
TELEPHONE 216 - 771 -1121
FAX 216- 696 -3545
e - moil proppeOproppe rom
PAUL COLTON & ASSOCIATFS
CONSULTING ENGINEERS
lvEi3•-q"
as 14 . ' 's s• se* +c• r- y.••
O' •-e-t; 4 - A•_w:•�•a ` ^! as•
ate 11 :e
LTE 1c3UE
'. '17/02 31C PERUf'
18/03 REr
as
raver' E. RCP DAF
HERSCNMAN
ARCHITECTS
'N
z
O
1 H-
Q
cc co
W Q
Z
O J
LL
0 w -
u 0
2 3 6 2 5
COMMERCE PARK
CI_EVEL AND OHIO
4 4 1 2 2
PHONE 2'6. 464 -4
FAX 21b - 464 0592
[-MAIL real box,T1
MP -2