Loading...
HomeMy WebLinkAboutPermit M01-145 - SOUTH 180TH STREET GRADE SEPARATIONM01-145 S 180 St Grade Separation 7220 S 180 St EX IRED JAN 1 0 2003 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: '1 City of 'tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 3623049059 7220 S 180 ST TUKW S 180 ST GRADE SEPARATION 7220 S 180 ST., TUKWILA, WA CULLEN ALLEN & JOAN 3613 61ST SW, SEATTLE WA ROBIN TISCHMAK 6300 SOUTHCENTER BL, TUKWILA WA WILDER CONSTRUCTION COMPANY 1525 EAST MARINE VIEW DRIVE, EVERETT, WA Contractor License No: WILDECC073K4 DESCRIPTION OF WORK: DEMOLITION OF A PORTION OF THE EXISTING BUILDING WILL REQUIRE MODIFICATIONS TO MECHANICAL COMPONENTS OF BUILDING. NO MECHANICAL ADDITIONS ARE PROPOSED. Value of Construction: Type of Fire Protection: AUTO FIRE ALARM Permit Center Authorized Signature: Signature: -P �- hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Print Name: rS T `i C- �'�`•� i Z — S doc: Mach MECHANICAL PERMIT $10,000.00 Fees Collected: M01 - 145 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 -433 -0179 Phone: Expiration Date: 04/01/2002 Uniform Mechnical Code Edition: Date: M01 -145 03/01/2002 08/28/2002 Date: 3 — 6 $65.00 1997 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 03 -01 -2002 DEPARTMENTS: Building Division Public Works ❑ \ PRROUTE.DOC 5/99 PLANLWAR'1 SLIP ACTIVITY NUMBER: M01 -145 DATE: 8 -27 -01 PROJECT NAME: S 180 ST GRADE SEPARATION SITE ADDRESS: 7220 S 180 STREET XX Original. Plan Submittal Response to Incomplete Letter # Response. to Correction Letter # Revision # After Permit. Is Issued CO", Fire Prevention RI— * wk B 41 Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete Comments: TUES /THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: CORRECTION DETERMINATION: Approved C Approved with Conditions REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved n Approved with Conditions REVIEWER'S INITIALS: Planning Division Permit Coordinator DUE DATE: 8 -28-01 Not Applicable n No further Review Required DATE: DUE DATE 09 -25 -01 Not Approved (attach comments) DATE: DUE DATE Not Approved (attach comments) DATE: ACTIVITY NUMBER: M01 -145 DATE: 8 -27 -01 PROJECT NAME: S 180 ST GRADE SEPARATION SITE ADDRESS: 7220 S 180 STREET XX Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comme TUES /THURS ROUTING: Please Route REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved n Approved with Conditions Not Approved (attach com ents) REVIEWER'S INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE Approved n Approved with Conditions Not Approved (attach comments) REVIEWER'S INITIALS: DATE: \PRROUTE.DOC 5/99 PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete s : Structural Review Required t61 Planning Division Permit Coordinator DUE DATE: 8-28-01 Not Applicable No further Review Required DATE: DUE DATE 09 -25 -01 n PERMIT NO.: O " 14 5 MECHANICAL PERMIT APPLICATIONS INSPECTIONS ❑ 00002 Pre - construction ❑ 00050 WSEC Residential ❑ 00060 WA Ventilation/Indoor AQC ❑ 00610 Chimney Installation /All Types ❑ 00700 Framing ❑ 01080 Woodstove ❑ 01090 Smoke Detector Shut Off 01 100 Rough -in Mechanical 01101 Mechanical Equipment/Controls ❑ 01102 Mechanical Pip/Duct Insul ❑ 01105 Underground Mech Rough -in 01115 Motor Inspection 1400 Fire Final 01800 Final Mechanical 04015 Special -Smoke Control System CONDITIONS 0001 No changes to plans unless approved by Bldg Div 0014 Readily accessible access to roof mounted equipment 0016 Exposed insulation backing material �,g 0019 All construction to be done in conformance (/� w /approved plans 0002 Plumbing permits shall be obtained through King Co 0027 Validity of Permit 0003 Electrical permits obtained through L & I "❑ 0036 Manufacturers installation instructions required on site ❑ "BTU maximum allowed per 1997 WA State Energy Code" ❑ 0041 Ventilation is required for all new rooms & spaces 0005 All permits, insp records & approved plans available "Fuel burning appliances ❑ "Appliances, which generate...." ❑ "Water heater shall be anchored...: Additional Conditions: TENANT NAME: S ' 16) &ra FEES e Basic Fee (Y/N) Supplemental Fee (Y/N) Plan Check Fee (Y/N) Furnace/Burner to 100,000 BTU (qty) Over 100,000 BTU (qty) Floor Furnace (qty) Suspended/Wall/Floor - mounted Heater (qty) Appliance Vent (qty) Heating/Refrig/Cooling Unit/System (qty) Boiler /Compressor to 3 HP /100,000 BTU (qty) to 15 HP /500,000 BTU (qty) to 30 HP /1,000,000 BTU (qty) to 50 HP /1,750,000 BTU (qty) over 50 HP /1,750,000 BTU (qty) Air Handling Unit to 10,000 cfm (qty) over 10,000 cfm (qty) Evaporative Cooler (qty) Ventilation Fan (qty) Ventilation System (qty) Hood (qty) Incinerator — Domestic (qty) Incinerator — Comm /Ind (qty) Other Mechanical Equipment (qty) Other Mechanical Fee (enter $$) Add'l Fees — Work w/o Permit (YIN) Insp Outside Normal Hours (hrs) Reinspections (hrs) Miscellaneous Inspections (hrs) Add' l Plan Review (hrs) Plan Reviewer: 4 A-- - Date: 8 (745' 4 l Permit Tech: bh Date: f3 .ZB -o( ACTIVITY NUMBER: M01 -145 DATE: 8 -27 -01 PROJECT NAME: S 180 ST GRADE SEPARATION SITE ADDRESS: 7220 S 180T STREET XX Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works \PRROUTEDOC 5/99 PLAN REVIEW /ROUTING SLIP n n Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete n Incomplete TUES /THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved Approved with Conditions REVIEWER'S INITIALS: Planning Division Permit Coordinator DUE DATE: 8-28-01 Not Applicable No further Review Required DATE: c./L`l /o1 DUE DATE 09 -25 -01 n Comments: Not Approved (attach comments) DATE: CORRECTION DETERMINATION: DUE DATE Approved n Approved with Conditions Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Project Name/Tenant: S 160 T— ST 62A nE. SEpA g&not✓ Val, of Mechanical E ui uent: If ID aaa � -- Site Address : City State Zip 7220 S Igo— 5T T v 1 � l ' I LA l.4)l�- 9 eI c' 8 Tax Parcel Nu 36230gi - 9059 - 08 f Property Owner: C tr'f D P T'vkw1t --A- Phone: (2 4 ) 3 - D 119 Street 2 -CO res $otrt ices.rre('� &vb. ruxipi . _ C a Q4 t i : t Fax 1l: ( zpe,) 1 13 I ' 3(0 b6 Contractor: NOT. SeL£cTE ‘(€.1- 1 � + t Phone: ( ) Street Address: City State /Zip: Fax it: ( ) Contact Person: Person: ' - p 131 N ( �SCi-} AAA g- Phone: (j,pr�) Lf33 — b 117 Street dre �NLeNTER �vo. , t okWr L.A 1 City ta( 18 toA Fax #: ( Zoe.) 413 I 3b 4 5 BUILDING OWNER 0 AUTHORIZED AGENT: Signature: Date: 8 - 27 _c I Printname: Roo DJ t IscolV Ag. Phone: ( 2d(p) q33 --40179 Fax #: (21040) 1 t3f - 36 5 �dd�s: R Q ` .X� f � w�cA TUk City /State/Zip: L A . 7'� ;clot Oh 4t1 S& CITY OF - ` 'JKWI LA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 • R STAFF I,JSE ONLY Project Number: Permit Number: Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. MECHANICAL PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) Description of work to be done (please be specific): 0 ■ 0 D F "`o - OF E E •i c t t J 6, 8J 1 LA 1 IJL Dm, Lk_ REV(IZE WW1 1F toN ME Cow\PoieJt OF 11-1 SvlLb1Nc . No MrcMAIJ 14.AL At biT ,JS AEE VThSSA Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form I -1-4, "Affidavit in Lieu of Contractor Registration Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State.of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will•be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review - Applications for which no permit is issued within 100 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: 11/2/99 much permit duc B Date application expires: 2-27-02_ Applicatio j -4jken by: (initials) S 5'� V Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. RESIDENTIAL: Two complete sets of attachments required with application submittal Submittal Requirements New Single. Family Residence Heat loss calculations. or Forni H -6. Equipment specifications.. • 11/2/9 u�lscpuiGduc lacement of existin mechanical e ui . ment Narrative of work to be done, including modification to duct work. Installation of Gas Fireplace Narrative with specification of equipment and chimney type. '.If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe condition. • NOTE: 'Water heaters and vents'are included in the Uniform.Mechanical Code — please include any water heaters or vents being installed or replaced. doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 3623049059 Address: 7220 S 180 ST TUKW Suite No: Tenant: S 180 ST GRADE SEPARATION PERMIT CONDITIONS 1: Readily accessible access to roof mounted equipment is required. 2: Any exposed insulations backing material shall have a Flame Spread Rating of 25 or less, and material shall bear identi- fication showing the fire performance rating thereof. 3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (296 - 4722). 4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (248- 6630). 5: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 6: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any con- struction. These documents are to be maintained and avail- able until final inspection approval is granted. 7: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 8: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be con- strued to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 9: Manufacturers installation instructions required on site for the building inspectors review. hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: ( - C C( —S M01 -145 Permit Number: M01 -145 Status: ISSUED Applied Date: 08/27/2001 Issue Date: 03/01/2002 Date: .? -6( - 6Z Printed: 03 -01 -2002 TRANSACTION LIST: Payment Other ACCOUNT ITEM LIST: doc: Receipt Current Pmts Amount MECHANICAL - NONRES PLAN CHECK - NONRES City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Payee: ACCT 104/01.595.500.63.59 RECEIPT Parcel No.: 3623049059 Permit Number: M01 -145 Address: 7220 S 180 ST TUKW Status: APPROVED Suite No: Applied Date: 08/27/2001 Applicant: S 180 ST GRADE SEPARATION Issue Date: Receipt No.: R020000292 Payment Amount: 65.00 Initials: SKS Payment Date: 03/01/2002 11:57 AM User ID: . 1165 Balance: $0.00 Type Method Description 65.00 Description Account Code 000/322.100 52.00 000/345.830 13.00 Total: 65.00 4364 03/01 1716 TOTAL 0.00 Printed: 03 -01 -2002 • ) INSPECTION RECC I Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISIO 6300 Southcenter Blvd., it100, Tukwila, WA 98188 NO. 6)431-3670 Project: Address:Y.. Special ilstru ctions: Type of Ir2s.pectioni Date Called: 6-c Date Wanted: Requester; y /7/e/ec Phone No: • Approved r per 'aPpliCahl.cOdes 14 Corrections required prior to approval. COMMENTS: f' v' -■C1,\ a>, ( tc Pf to v e la-At Try- Date: ?-2 2 0-2 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at t300 Southcenter Blvd., Suite 100. Call to schedule reinspection. r eceipt No.: . - !Date: • • 1 • ' • ".: . ' , W in 0 co w • W W 0 } ' J'. U.. Qi N • Cf 0 H; W W; U. U. O ! — Z! 111 This inspection is intended to determine if substantial work has been accomplished since issuance of the 0 permit or last inspection; or if the project should be considered abandoned. The Building Code does allow the Building Official to approve a one - time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicant's control have prevented action from being taken. January 6, 2003 Mr. Robin Tishmark City of Tukwila 6300 Southcenter BI Tukwila, WA 98188 Dear Permit Holder: City of Tukwila Department of Community Development Steve Lancaster, Director RE: Permit Application No. M01 -145 Location: S. 180 St. Grade Separation 7220 S 180 St. In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: •Call the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next scheduled inspection In the event you do not call for the above inspection or request and receive an extension prior to February 22, 2003, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, K,G. ins Kathryn A. Stetson Permit Technician Xc: Permit File No.M01 -145 Bob Benedicto, Building Official Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 -431 -3665 July 3, 2002 Mr. Robin Tischmak 6300 Southcenter BI Tukwila, WA 98188 RE: Permit Application No. M01 -145 Location: S 180 ST GRADE SEPARATION 7220 S 180 St Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: A progress inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicant's control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to August 28, 2002, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Kam 0. Kathryn A. Stetson Permit Technician City of Tukwila Department of Community Development Steve Lancaster, Director • Call the City Of Tukwila Permit Center at (206) 431 -3670 to schedule a progress or a final inspection Xc: Permit File No.M01- 145 Bob Benedicto, Building Official Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206.431.3665 ; • , 03/01/02 FRI 11:21 FAX 425 551 3118 P623-052-000 (1/97) Detach And Display Ceitificata 444 GRADE SEP WILDER EVT/B ID GD REMOVE SIDE EDGES FIRS"' THEN, CREASE AND TEAR THIS STUE ALO, WiRFORATION REGISTERED AS PROVIDED B LAW AS CONST CONT GENERAL . REGIST #... EXP . DATE CCO1 WILDECCO 73K4 0.4 /01./2002 FEIECTIVE-DATE • — 05/2.I /1993 'J'. 1, /OA. W. I LDEA2 CONSTRUCTION • cOMP.R1Y g25 E yzEw . .2. • ; • • " EVEItETT• : WA!' 98291 L 192 • Signature Issued by DEPARTMENT OF LABOR AND INDUSTRIES Please Remove And Sign Identification Card Before Placing In Billfold t ooi 4 • • •', • ':,;„ • .. .L.. . . • F.:: •.{ .. ... {:} } } } } } }:3: {:.:v: }::: }:: /� ny� :• ... '. •(: }:i:•::: }: + : .. v} : : .. : : .... i • } ?'. ..�r����{�. . }`•} r.... ;. . . rr:.:.v:::N..,... x : ?h:•} ? ?• }' ?:h }:•.v...n ....... r r.:::::r ::`+? ::;: �$ L•: h ':::`: :$:!: %•', ;: + ?i• {ih::•v �, ?•.v yv.:. n:Y.2 x; �. m.. .. ?: is {t:$$i: +: ^ + : •'� $ <$. { i�4 }:•$$$; . n ., y vi'{h' <$i��4� . .f.. rr.::.:::. M: ........ ::. v. r::.•v.vv ... ... ....... ......:..... {.;..v , v::::::: •. ..s ::{ i:': is •.: ` }: ?:: � y f # ; y :rv; r.: v:..:: ......:, ..x.:,:.:$•:•:•,:•:::•:•:•:•:•:•:•:.. . } } }:h }:? {. } } x..r : ....... •..:... 6 - 33 . glance Due: $ cT /0 /6 / 59f.5-619. (0 3.5 - 9 d eed Current Contractor. Registration Card: Yes ❑ No eed to. Enter. Contractor Information in Sierra: Pc . ❑ No i•1 'Siit'rsi��: °i:i:; tiff:', i': �?�il'���':'.. }�:ta.•j.a ='s' >= ;�u:%i;':;i; a';sxxr; PLUM !NG LEGEND . SYMBC — DE OR'PT;3N COLD WA ;CA. - — — -- -- : WASTE OR SANiTArRY SEWER VENT (V,) I NAT URA _ GAS G EXISTING PIPING -- E GATE ` ✓AL' /E (Gv) — , X BC TERFLv VALVE PRESSuRE REDUCING VALVE (P v; CHECK VALVE (CV) T _.* : : — BA__ VAL': E PIPE DOWN C P,PE. UP Ch BRANCH -TOP CONNECTION --t- � BRANCH- BOTTOM CONNECTION BRANCH-SIDE CONNECTION a CAP END CF PIPE FLOW D!RECT!ON f f FLUSH/SURFACE CLEANOUT (FCG /SCC) 0 C FLOOR DRAIN (FD) PIPE GUIDE TRAP PRIMER WITH ACCESS PANEL REDUCER 1 STRAINER -- T ( —1 UNION I FREEZEP<.00F WALL HYDRANT (FWH) \ GAS COCK ,. AFF ABOVE FINISHED FLOOR BFF BELOW FINISHED FLOOR POC POINT CF CONNECTION MC MECHANICAL CONTRACTOR EC ELECTRICAL CONTRACTOR - GC GENERAL CONTRACTOR 1908 GENERAL NOTES z 114" PARTIAL SCALE: 1/8" PLAN = 11_0„ ' 1 34 4° �rPOC r I. THE DRAWINGS AND DETAILS SHOWN FOR THE EXISTING BUILDING ARE DIAGRAMMATIC IN NATURE AND ARE NOT INTENDED TO REPRESENT AS -BUILT CONDITIONS. EXISTING CONDITIONS ARE REPRESENTED AS COMPLETE AS POSSIBLE, BUT FIELD VERIFICATION MAY BE NECESSARY 2. THE RELOCATED GAS -FIRED UNIT HEATER MODEL #: REZNOR CEEXL75. INPUT = 75,000 PTU /H; OUTPUT = 60,OOC BTU /H. 3. ABOVE GROUND DOMESTIC WATER PIPING TO BE TYPE " L" COPPER. BELOW GROUND SHALL BE TYPE "K" COPPER. - ENGINEERING- STREETS- WATER - SEWER- PARKS- BUILDING- c� 2 16 6 SCO 6" WASTE® r' I_.JH3I_,YC, WC)I�I <S L71 I'T. 1 4 - XIS • \-) ELECTRIC - - 1°' - . HCT WATER HEATER S c s E )_ 4 0 — EX STING GAS -FIRED HCT WATER HEATER [ I 1 PARTIAL PLAN - MECHANICAL DEMOLITION SCALE: 1/8" = 3/- UP TO EXISTING FURNACj ON SECOND FLOOR 6 I N 1 - MECHANICAL REVISIONS 4. ALL DOMESTIC WATER PIPING SHALL BE FLUSHED AND CHLORINATED TO REMOVE ALL DIRT AND BACTERIA. 5. ALL PIPING SUPPORTS SHALL BE IN ACCORDANCE WITH STANDARD MSS SP -89, MSS SP -69, UPC AND UMC. HEATING VENTILATION AND AIR CONDITIONING EQUIPMENT WHERE SUSPENDED FROM STRUCTURE SHALL BE SUPPORTED PER SMACNA HVAC DUCT CONSTRUCTION STANDARDS. 6. ALL VALVES TO COMPLY WITH ANSI REQUIREMENTS. 7. ALL ABOVE GROUND SOIL, WASTE AND VENT PIPING SHALL BE HUBLESS CAST IRON PIPE AND FITTINGS AND STAINLESS STEEL COUPLINGS WITH NEOPRENE GASKETS CONFORMING TO ASTM C -564 AND FEDERAL SPECIFICATION UWP -801. designed drown checked proj eng prof dir fleld bk no b y AH AH CC AH date DEMOLITION NOTES • EXISTING GAS METER TO EE RELOCATED GAS PIPING SHALL BE REMOVED WHERE INDICATED ON PLANS • _XIST:NG GAS FIRED UNIT HEATER TO BE RELOCATED. ASSOCIATED FLUE AND DUCTING SHALL BE RE :1OVED. C EXISTING VENT PIPING AND ROOF VENT TO BE REMOVED. 4 EXISTING MEC:-IANK:AL AIR FILTER UNIT TO BE REMOVED O5 EXISTING FLOOR DRAINS TO BE REMOVED. ✓ WASTE PIPING TO BE REMOVED WHERE INDICATED ON PLANS. • DOMESTIC COLD WATER HEADER A.SSEMBL" SHALL BE RELOCATED. DOMESTIC COLD WATER PIPING FROM THE HEADER SHALL BE REMOVED WHERE INDICATED ON PLANS. ® EXISTING PIPE HEADER TO REYAIN. • EXISTING PLUMBING FIXTURES TO REMAIN. EXISTING HOSE BIBB TO BE REMOVED. . 4 BF. RC;EK /ABAM + r,c CONSTRUCTION NOTES O1 RELOCATED GAS -FIRED UNIT HEATER SHALL BE SUSPENDED FROM STRUCTURE. ® RELOCATED GAS METER .AND REGULATOR. VERIFY PRESSURE AND `VOLUME Wi H RANDY BUSCH AT PUGET SOUND ENERGY (425) 462 -3965. CONTRACTOR RESPONSIBLE FOR CONTACTING GAS COMPANY FOR COORDINATION REQUIREMENTS. 0 RELOCATED COLD WATER HEADER. RECONNECT EXISTING PIPING AND NEW SERVICE PIPING AS SHOWN ON THE "WATER SERVICE DIAGRAM" DETAIL, THIS SHEET. ® SEE CIVIL DRAWINGS FOR CONTINUATION OF UTILITIES. ® 4" FLUE UP TO ROOF CAP. SEE "FLUE THROUGH ROOF" DETAIL, THIS SHEET. COORDINATE EXACT LOCATION OF FLUE WITH EXISTING STRUCTURE. ® EXISTING PIPE SIZES SHOWN ARE APPROXIMATE. FIELD VERIFY EXACT SIZE. NOTE: SURFACE CLEANOUT (SCO) SHALL COMPLY WITH CITY OF RENTON STANDARDS. 16" SQUARE CONCRETE PAD TROWEL SMOOTH AND EDGE 1/8" BEND IF CLEANOUT OCCURS AT END OF LINE TYPICAL BELOW GRADE WASTE PIPE COUPLING CONSULTANT 33301 9TH AVENUE SOUTH FEDERAL WAY, WASHINGTON 98003 -2600 VOICE: (206)431 -2300 FAX: (206)431 -2250 1 6" CLEAN TO GRADE (SCO) DETAIL DIAGRAMMATIC BRASS CLEANOUT PLUG W /COUNTER SUNK HEAD. FINISHED FLOOR ji T BLDG #7 0 1/8" PVC BEND PVC WASTE LINE LENGTH TO SUIT. - WASTE LINE. EX°ST":'-:.; RELOCATED COLD WATER HE -TEri TC BE RECONNECTED TO = xiSTING COLD WATER PIPING THAT SERVES THE BUILDING. FIr\ISHEC FLOOR CCNNEC:;T TO EXISTING CW PIPING Date - Pf�r No 0 1 VI( t onS ulegsS9 040-1- SSE- MO M,�,,, WO 9. NATURAL GAS PIPING SHALL MEET REQUIREMENTS OF ASTM A 53 -87b. 10. GAS FITTINGS SHALL BE WELDED FORGED STEEL OF ASTM A 234 -87 OR WEIGHT MALLEABLE IRON SCREWED. I underft and that. the np a�,:. ��alo are subject to errors ax4 and approval of plans _;:5 not authorize the v Nation of any adopt ::;ode or are+ ; +ar, „e. ?e e ct Pon - :ra;,tor's copy of approved F ens acfc r.;,v, +mod S ed. By .see. e - s S EPARATE PERMIT REQUIRED FOR: C -_ CHANICAL r ECTRICAi_ 1 , UINBING ,S PIPING CITY OF TUKWILA BUILDING DIVISION NOTE: VERIFY PITCH OF ROOF AND PROVIDE BLOCKING AND FLASHING AS REQ'D 8. ALL SOIL, WASTE, AND VENT PIPING BELOW GROUND SHALL BE P\:C PIPING CONFORMING TO ANSI /ASTM D 2665 -94. FITTINGS SHALL COMPLY WITH CURRENT UPC. 11 MATERIALS AND INSTALLATION SHALL BE IN ACCORDANCE WITH THE SERVING UTILITY. 1 0 2003 20 ME HANICAL FLOOR PLAN FLUE SOUTH 180th STREET GRADE SEPARATION r 1 4 V SHEATHING , DOUBLE WALL FLUE POC TC :XIS T ING CW HEK ER WATER SERVICE DIAGRAV DIAGRAMMATIC PIPE SLEVE (TYF 'UAL; T 7 , ONTINUATION SEE CIVIL PLANS - CEILING L no 8/20/01 dat,s THRU ROOF DETAIL NOT TO SCALE ADDEMDUM 1 - NEW SHEET revisions FLUE CAP W /DAMPER 0 EX ST'NG CW PIPING BOTTOM OF FLUE CAP SHALL BE 2' -0” MINIMUM WITHIN 10' -0" ABOVE ANY ROOF NON- HARDENING CAULK FLASHING 2" MIN. CLEAR ESCUTCHEON PAINT TO MATCH CEILING REC - E lV v . . Gam' AUG 2 7 ?n4! — D LL ENGINEERS, INC. 8021 12TH STREET E., SUITE 200 T A C O M A , W A 9 8 4 2 4 (253) 922-0446 FAX (253) 922-0896 M1 2100 5TH AVE., SUITE 200 SEATTLE, WA 98181 (206) 405 -3975 FAX (206) 406-3976 1 0 01 EASTSIDE STREET. SUITE C O L Y M P I A , W A 98057 (360)706.2565 FAX (360) 943 -6837 sheet25Aof144 Job no A00084 scale AS SHOWN dote 16 -AUG -2001 KA I_ 1v' H ELECTRICAL LEGEND SYMBOL DESCRIPTION CIRC. {CIR. BRKR. NO. CIRCUIT DIRECTORY RACEwA CONCEALED IN WALL OR CEILING 632 ItiCICATES _x-ST NG '0 BE RETE.NED FOR AL_ OE': C_S 1 HOMERUN "0 PANEL O RECESSED FLUORESCENT LIGHT FIXTURE 2 RECEP - AC LES - 1ST FLOOR RACEWAY CONCEALED UNDERGROUND OR UNDER FLOOR 534 SURFACE OR PE NDANT MOUNT FLUORESCENT LIGHT -IXTURE 3 1P-20A FLEXIBLE CONDIT 1P-20A WALL MOUNT H.I.C. LIGHT F XTURE RECEPTACLES - 1ST FLOOR GROUNDING SYSTEM PER CODE 88 INCA' DESCENT L+GrT FIXTURE 5 JUNCTION BOx - SIZE PER CODE I WAL_ MOUNTED INCANDESCENT LIGHT FIX1UFE 6 MOTOR CONNECTION 906 4500 WATER HEATER 7 2P SINGLE P011 SWITCH DISCONNECT SWITCH 8 , RECEPTACLES - 2ND FLOOR 900 9 MULTI-GANGED SWITCH M I ELECTRICAL METER e THERMOSTAT �_ 900 120/208 VOLT PANELBOARD (OR AT RATED VOLTAGE AS NOTED) 3P SMOKE DETECTOR' WITH BASE 1P-20A EXISTING MAIN DISTRIBUTION BOARD TO BE RETAINED RECEPTACLES - 2ND FLOOR Fi LL STATION - MOUNT AT -48" AFF 2710 TELEPHONE PEDESTAL 13 COMBINATION HORN /STROBE - MCAT AT +8C" AFF OR 6' BELOW CEILING, W 'iICHEVEF IS LOWER UTILITY VAULT (P INDICATES POWER, T INDICATES TELEPHONE) COMBINATION BE__ /STROSE - EXTERIOR RATED 14 FURNACE - 2ND FLOOR �n O i DUPLEX RECEPTACLE TRANSFORMER • 1P-30A 16 DUPLEX RE.;EPTACLE (C INDICATES CEILING MOUNT) CONSTRUCTION NOTES SPACE ONLY 17 SPECIAL PURPOSE OUTLET - 1 PHASE OUTLET WITH DUPLEX RECEPTACLE IN SINGLE BOX W INDICATES WEATHERPROOF FOR ALL DEVICES, PROVIDE LOCKING COVER ON RECEPTACLES. 18 UNITI -EATER 670 KEYPAD DASHED INDICATES EXISTING TO BE REMOVED FOR ALL DEVICES FIRE ALARM CONTROL PANEL 1P-20A LOAD CIRCUIT DIRECTORY CIR. NO. CIRC. 1 i BRKR. !A B C CIRC. {CIR. BRKR. NO. CIRCUIT DIRECTORY LOAD 632 LIGHTS - 1ST FLOOR 1 1P-20A O 1P-20A 2 RECEP - AC LES - 1ST FLOOR 720 534 LIGHTS - 2ND FLOOR 3 1P-20A 1 ! 1P-20A 4 RECEPTACLES - 1ST FLOOR :20 88 LIGHT - EXTERIOR 5 1P-20A I 1P-20A 6 RECEPTACLES - 2ND FLOOR 906 4500 WATER HEATER 7 2P 1P-20A 8 , RECEPTACLES - 2ND FLOOR 900 9 r' 30A 1P-20A 10 RECEPTACLES - 2ND FLOOR 900 111 3P 1P-20A 12 RECEPTACLES - 2ND FLOOR 900 2710 PUMP 13 • 1P-20A 14 FURNACE - 2ND FLOOR 1130 15 20A • 1P-30A 16 AC UNIT- 2ND FLOOR 1600 SPACE ONLY 17 • 1P -20A 18 UNITI -EATER 670 SPACE ONLY 19 } 1P-20A 20 SPARE SPACE ONLY 21 i • 1P-20A 22 SPARE SPACE ONLY 23 1P-20A 24 SPARE SPACE ONLY 25 26 SPACE ONLY SPACE ONLY 27 • ; 28 SPACE ONLY SPACE ONLY 29 30 SPACE ONLY 8464 TOTAL VA= 16,904 CURRENT 47.0 AMPS DIVERSITY % DEMAND VA= 17,218 DEMAND CURRENT 4T8 AMPS 8440 I {y\ `- -T T PAD MOUNT TRANSFORMER TO B E RELOCATED BY UTILITY CO. SECONDARY TERMINATIONS BY UTILITY CO. ALL TRENCHING, BACKPLL AN.=; COMPACTION BY DONTRACTOR. 4" PVC CONDUIT ONLY TO EXISTING POWER \ VAULT BY CONTRACTOR. CONDUCTORS BY UTILITY. n CONTRACTOR TO PROVIDE CONDUIT & TRENCHING FOR ALL UTILITIES. (4" rpY(=.‘ FOR PHONE, 4" TRS FOR PRIMARY POWER) SEE .ALSO RISER DIAGRAM. VAULT BY UTILITY CO. TRENCHING BY CONTRACTOR EXISTING CT ENCLOSURE, CONDUCTORS, CONDUITS, AND METER TO REMAIN. v i SCALE: 1" = 20' -0" C EXISTING HANDHOLE TO BE REMOVED BY CONTRACTOR. NEW ;1) 4" GRS CT NDUIT WITH (4) #500 MOM THW -CU. DIAGRAMATIC \-- NEW .00A OF TRANSFORMER COORDINr'= WITH PUGET SOt,ND ENERGY - -T r- ELECTRICAL SITE PLAN POWER RISER DIACRry EXISTING 400A MAIN PANEL TO REMAIN. MAIN SAN JI3 LAC: '�TC�I`KS —ENGINEERING—STREETS—WATER—SEWER—PARKS—BUILDING /,,— r G -MAN PANE 10 REMAIN EX' STING ELECTRICAL CONDUIT. CONTRACTOR TO PULL EXISTING CONDUCTORS AND ABANDON CONDUIT. EXISTING PAD -MOUNT TRANSFORMER TO BE RELOCATED BY UTILITY. FOR MORE INFORMATION, CONTACT BRIAN SWART WITH PUGET SOUND ENERGY AT (253)395 -6839. PHONE VAULT AND SERVICE BY OTHERS. EXISTING CONDUIT AND CONDUCTORS TO BE REMOVED BY CONTRACTOR. EXISTING BRANCH PANEL L„ TO BE REMOVED . NEW BRANCH PANEL 'PA' (1) 2" EMT CONDUIT WITH (4) #1 THW -CU. DEAD FRONT, 100% NEUTRAL (SQUARE D, GE OR ITE) COMPLETE WITH NAMEPLATE & GROUND PER CODE. PANEL PA SURFACE MOUNT 3 0 4 WIRE 30 POLES 120/208 VOLTS TOP FEED 100A MAIN LUGS ONLY 10000 AIC MIN' RECEIVED CITY TUKWr A AUG `? ; 'tiO1 PERM` Etv -E designed drawn checked proj eng proj dir field bk no by RAA 70 BAN BAN date t3ERGE1? /A HAM G. M Ok CONSULTANTS 33301 9TH AVENUE SOUTH FEDERAL WAY, WASHINGTON 98003 -2600 VOICE. (206)431 -2300 FAX: (206)431 -2250 +45 no BLDG #7220 ELECTRICAL LEGEND, SITE PLAN AND RISER DIAGRAM SOUTH 180th STREET GRADE SEPARATION 8/20/01 ADDEMDUM 1 — NEW SHEET date revisions ENGINEERS, INC. 8021 12TH STREET E. BUTTE 20C TACOMA W A 9 8 4 2 4 1253) 922-0448 FAX (253) 922-0896 2100 5TH AVE., SUITE 200 SEATTLE. WA 981 61 (206)405.3675 FAX (206) 405-3976 100 EASTSIDE STREET, SURE C OLYMPIA. W A 98057 (360) 706.2565 FAX (360) 943-6837 El sheet 260 of 144 job no 201 -108 scale AS SHOWN date 16 -AUG -2001 UNIT HEATER 120V, 10, 670VA HVAC UNIT, LOCATED O ROOF OF OFFICE 1 1 J T � —BEAM - r , I H L * y r i PoMP 208V, 32 ✓ I r I L L (J) ) f,D T 1 I J- J TELEPHONE BACKBOARD P r Ern (z) F -- � II, L —J NEW 4" P'JC TELEPHONE i T 1 L J- J 7m rn r CII � r IIC I I J r T (y RECEPTACLE FCR CI I \ LIGHTING FIXTURE. `LOCATED ON \ CEILING (TYPICAL 6). r .-NEW 100A BRANCH PANEL 'P.. � TO FACP CTO L 0 11 (�r ( ' y ji� r � HEATER . J O 4` TO XFMR �- �,�- WATER HEATER ,- 4.5KW, 240V, 10 1 B L. I C W O R 'KS D E -ENGINEERING--STREETS- WATER- SEWER - PARKS - BUILDING- 1 PARTIAL PLAN -LEVEL 1 - SCALE: 1/4" = 1' -0" - CAS HEATER I designed drawn checked proj eng prof dir field bk no PARTIAL PLAN -LEVEL 2 by RAA TPO BAN BAN 1/4" = 1' -0" date CONSULTANTS 33301 9TH AVENUE SOUTH FEDERAL WAY, WASHINGTON BEIKGER /A13AM 98003 - 2600 VOICE: (206)431 -2300 FAX (206)431 -2250 G h e .1 C MOI-U45 BLDG #7220 ELECTRICAL PLANS AND PANEL SCHEDULE SOUTH 180th STREET GRADE SEPARATION no date 1 EXPIRES 499/26/07 3/20/01 ADDEMDUM 1 — NEW SHEET revisions ENGINEERS, INC. 6021 12TH STREET E., SUITE 200 TACOMA, W A 9 8 4 2 4 (253) 922-0448 FAX (253) 922-0896 2100 511-1 AVE., SUITE 200 SEATTLE, WA 98181 (206) 405-3975 FAX (206) 406-3976 100 EASTSIDE STREET, SUITE C OLYMPIA, WA 98057 (360) 706-2565 FAX (360) 943 -6837 E2 sheet 26C of 144 Job no 201 -108 scale AS SHOWN date 16 —AUG -2001 E CCNSTR���.�TiON kjQTTC 1 DE'I'CES LOCATE ON OVERHEAD BEAM. 2 , EXISTING BELL W'T-, STROBE. TO BE RELOCATED AS INDICTED. RE CONNECT TC FIRE A_ARM PANEL. CONTRACTOR TO REMOVE ALL EXISTING LIGHTING FIXTURES, RECEPTACLES, DEVICES, WIRES, AND CONDUIT IN THIS AREA. CONTRACTOR TO REMOVE EXISTING CONDUCTORS AND ABANDON EXISTING CONDUIT. Q CONTRACTOR TO REMOVE EXISTING DEVICE AND ALL RELATED CONDUIT, CONDUCTORS, AND BOXES. ® CONNECT EXISTING DEVICES TO NEW PANE_ AS INDICATED ON PANEL SCHEDULE FOR RECEPTACLES, WIRE 6 MAX. ON ONE 20AMP CIRCUIT. O PROVIDE NEW HID WALL -PACK FIXTURE (GE# WL 07 S 1 PE) ON NEW EXTERIOR WALL. CONNECT TO LIGHTING CIRCUIT AS REQUIRED. MOUNT AT ±10' -0 ". AIR CONDITIONING UNIT /MAX 30 AMP, 120V, 10 O GENERAL \OTES ® CONTRACTOR TO DISCONNECT - GLI ?MENT AND REMOVE ALL CONDUIT, CONDUCTORS, AND RELATED SNITCHES. MECH. E:., PVENT TO BE REMOVED B MC. SEE NOTE 4 ON SHEET M . CONTRACTOR TO REMOVE EXIS TING 200A, 3C POLE BRANCH PANELBOARD. EXISTING KEYPAD. RELOCATE TO NEW EXTER!OP DDOR. INTERCEPT EXISTING CONDUCTORS AND RECONNECT AS REQu :RED. COORDINATE WITH THE OWNER'S VENfOR. EXISTING UNIT HEATER TO BE 'RELOCATED AS INDICATE. , BY MC. CONTRACTCR SHALL DISCONNECT EOUPMENT AND REMOVE ALL EXISTING CONDUCTORS AND OONDUIT. PRDViDE CONNECTION FOR RELOCATION AS REQUIRE :,. i 2 TELEPHONE DEMARCATION POINT - FIELD VERFY & ,LOVE TO NEW TELEPHONE BACKBOARD ON NEN WALL @ OPIDLINE 3. EXTEND UNDERGROOND CONDUIT (4 "PVC) TO NEW BACKBOARD AS REOU REC ALL EXISTING' PHONE LINES SERVING= OEEICES ON SECOND FLOOR &c FIRS FLOOR SHALL BE REROUTED & TERMINATED @ THE NEW BACL,BCARD COMPLETE & FUNCTIONAL. COORDINATE 'WIT- OWEST (DENNIS (206)304 -4484; FOR ALL WORK. PROVIDE 4" EMT SLEEVE THRU FOOTING & UP TO TELEPHONE BACKBOARD. SEE STRUCTURE DWGS. 14' RUN OVERHEAD FEEDER TO MAN PANE_ AS PER ONELINE RISER. SEE El FOR LOCATION. EXISTING FIRE ALARM CONTROL PANEL, TO BE RETAINED. (LOCATION APPROXIMATE) J' TO XFMR / MAN PANEL, TO r BE RE _•iNED. , 400A EX'STING CT - ENC LOSLRE, TO BE RETAINED. *. " -- -- EXISTING METER, TO BE RETAINED. 1 EXAMINE THE STRUCTURE, BUILDING, AND CONDITIONS UNDER WHICH THE ELECTRICAL WORK IS TO BE INSTALLED FOR CONDITIONS DETRMENTAL TO PROPER AND TIMELY COMPLETION OF THE WORK. DO NOT PROCEED WITH WORK UNTIL DEFICIENCIES ENCOUNTERED IN INSTALLATION HAVE BEEN CORRECTED. REPORT ANY DELAY OR DIFFICULTIES ENCOUNTERED IN INSTALLATION OF THE ELECTRICAL WORK WHICH MIGHT BE UNSUITABLE TO CONNECT WITH WORK BY TRADES. FAILURE TO REPORT CONDITIONS SHALL CONSTITUTE ACCEPTANCE OF OTHER WORK AS BEING FIT AND PROPER FOR THE INSTALLATION OF THE ELECTRICAL WORK. 2. MAINTAIN CONTINUITY OF EXISTING CIRCUITS OF ECUPMENT TO REMAIN. CIRCUITS WHICH ARE TO REMAIN BUT WERE DISTURBED DURING DEMOLITION SHALL. HAVE CIRCUITS WIRING AND POWER RESTORED BACK TO ORIGINAL CONDITION. 3. PANELBOARD, SIGNALING SYSTEMS, OTHER ELECTRICAL EQUIPMENT FREE STANDING (OR SURFACE MOUNTED), RACEWAY (EXPOSED) AND CONDUCTORS NO LONGER OF SERVICE AS A RESULT OF THIS CONTRACT SHALL 3E REMOVED. UNUSED RACEWAYS OR SLEEVES SHALL BE CUT FLUSH AT CEILING, FLOOR OR WALL AND FILLED WITH GROUT. >•-A- A. NG& RECE N E'.. CITY OF' WILA AUG 2 7 rlil l PERMIT TER