Loading...
HomeMy WebLinkAboutPermit M06-091 - SHAMROCK CENTER - BUILDING ASHAMROCK CENTER BUILDING A 4600 S 134 PL M06 -091 Parcel No.: 2616600045 Address: 4600 5 134 PL TUKW Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: Contractor City b? Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us SHAMROCK CENTER BLDG A 4600 S 134 PL, TUKWILA WA HOLADAY-PARKS, INC 4650 5 134T1-1 PL, BLDG #C PEGGY PEEL 4600 5 134 PL, SEATTLE WA HOLADAY PARKS, INC. PO BOX 69208, SEATTLE, WA License No: HOLADPI379N0 Value of Mechanical: $7,500.00 Type of Fire Protection: Furnace: <100K BTU 0 >100K BTU 0 Floor Fumace 0 Suspended/Wall /Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System 1 Air Handling Unit <10,000 CFM 1 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial /Industrial 0 MECHANICAL PERMIT DESCRIPTION OF WORK: INSTALL (1) NEW COOLING ONLY AC SPLIT SYSTEM IN REPRO ROOM. Permit Number: Issue Date: Permit Expires On: EQUIPMENT TYPE AND QUANTITY * *continued on next page ** Phone: (206)248 -9700 Phone: 206 248 -8747 Phone: 206 248 -9700 Expiration Date:09 /03/2007 Steven M. Mullet, Mayor Steve Lancaster, Director MO6 -091 05/15/2006 11/11/2006 Fees Collected: $246.53 International Mechanical Code Edition: 2003 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP/1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood /Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment... 0 doc: IMC- Permit M06.091 Printed: 05 -15 -2006 Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances goveming this work will be complied with, whether specified herein or not. The grantin regulating Signature: Print Name: doc: IMC -Permit of th ns City 6? Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M06-091 Issue Date: 05/15/2006 Permit Expires On: 11/11/2006 ��-L Date: 0•lis1 C oes nit presume to give authority to violate or cancel the provisions of any other state or local laws mance • w•rk. I am authorized to sign and obtain this mechanical permit. V ■ I Date: S I C- L Pet re-1 • This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M06 -091 Printed: 05 -15 -2006 City of Tukwila Parcel No.: 2616600045 Address: 4600 5 134 PL TUKW Suite No: Tenant: SHAMROCK CENTER BLDG A 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS * *continued on next page ** Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Permit Number: 1406 -091 Status: ISSUED Applied Date: 05/08/2006 Issue Date: 05/15/2006 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, Inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 6: VALIDITY OF PERMIT: The Issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Conditions M06 -091 Printed: 05 -15 -2006 Signature: Print Name: City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granti this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulatin constrylction or the performance of work. n n(Acf L. HarcNii Date: S ( S — 0 doc: Conditions M06 -091 Printed: 05-15 -2006 lbed CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: , S. 13 y S /2Q Tenant Name: SAaiair 8 A 7; Property Owners Name: «tos i4 ^ ' M e e r C.1 y L LC. Mailing Address: ¥(eeo S , /3 -� P Name: f i eygy Pee/ Day Telephone: 00 -JsIt 1 747 Mailing Address eR "OERECO. q:\pa nia pluVcc dunges`pentit ypliaton (7-2006) Revised 64-05 M S / ' 2e S'eeattle tJA 9t .e City State Zip E -Mail Address: *e9 p a ptr KS. P 0e,1 Fax Number: 20Le - 2i/R - cis 700 Page 1 King Co Assessor's Tax Nod ...VW - 3 ',it ve 7 Suite Number: Floor: 4 New Tenant: ❑ Yes aV' No ectianicatCoa city et-'stamped by Englneer of W,4 97 /6 State Company Name HO L A b AY PARKS NO Mailing Address: 7 (a0 0 S. f 3 et ft '1 5 tt1 9 g &og City State Zip Contact Person: Pt-yq Sr Pe.I Day Telephone: .2 o in - ,2 8 - E-Mail Address pa ? lb r5 at7 lta (a eta �� 1 n rKS.l ,� rr5 Fax Number: 20 lo - ,?•7Q - V7 O 0 Contractor Registration Number: //0 LA D Pt - 179449 Expiration Date: t O 7 * *An original or notarized copy of current Washington State Contractor License must be presented at a time of permit issuance* JARCFIITECT OF RECORD .AI1 pl ans must he wet stamped by Arcditi Company Name Mailing Address City Contact Person: Day Telephone: E-Mail Address: Fax Number: State Zip Zip Company Name: Mailing Address state City Contact Person Day Telephone: E -Mail Address: Fax Number: Zip " V Umt �, _ :: � • Qty[; . Unit'�p ` : n. .e: (� . �= ETuit Type = < ;; Qfy : i l . r / . � Boie�6inpresson :.: QtY Furnace<100K BTU Air Handling Unit >10,000 CFM • Fire Damper 0-3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Themtostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30-50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1 750,000 BTU Repair or Addition to Heat/R.efrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling <10 000 CFM Incinerator - ComMd m Other Mechanical Equipment MECHANICAL CONTRACTOR INFORMATION Company Name* fla t /},d/¢ V P4 tt s LNC Mailing Address 4 S. /3IS P/ , Seattle, t � City / ¢ is / Day Telephone: Contact Person: ( Tha 1q E- Mail Address90l?y Aa rec. CD r11 Fax Number: 2Ob - 21f: g700 1 9 Contractor Registration Number: � 3 Sat 79/8e, Expiration Date: e0 7 * *An original or notarized copy of current Washington State Contractor License must be presented at th time of permit issuance** Valuation of Project (contractor's bid price): $ Coo • °S Scope of Work (please provide detailed information): T.rc /l (r) ne..) Poo /in e t1 1 r /4 sp/ i s c &ent.. I n re frn roam - Sag: Residential: New .... Replacement .... ❑ Commercial: New .... ❑ Replacement .... ❑ Fuel Type: Electric Er Gas....❑ Other: Indicate type of mechanical work being installed and the quantity below: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no petit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMTT. BUILDING OWNER OR AUTHORIZED AGE n Signature• ca- e. -wily. of ■ r . Print Name: , Peal ')� Mailing Address: ¥410 S. /r3 4� r l � P a .f* 1 `C City • Date Application Expires: Date Application Accepted: f q:Vya^un plutiu ehnga`paait "Ocoee (7 -2011) Revisal: 64-05 bh Page 4 LIM 9948 State Zip A.7o 4 --/AIR-87#7 Date: lifA ro Day Telephone: c O 6 -� 1 g Tee 7 t11A 9g /log State Zip Staff Initials: City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2616600045 Permit Number: M06 -091 Address: 4600 S 134 PL TUKW Status: APPROVED Suite No: Applied Date: 05/08/2006 Applicant: SHAMROCK CENTER BLDG A Issue Date: Receipt No.: R06 -00666 Payment Amount: 203.22 Initials: LAW Payment Date: 05/15/2006 01:57 PM User ID: 1630 Balance: $0.00 Payee: HOLADAY-PARKS INC TRANSACTION LIST: Type Method Description Amount doc: Receipt Payment Check 154645 203.22 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES RECEIPT Account Code Current Pmts 000/322.100 203.22 Total: 203.22 5413 05/15 9716 TOTAL 203.22 Printed: 05 -15 -2006 City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2616600045 Permit Number: M06 -091 Address: 4600 S 134 PL TUKW Status: PENDING Suite No: Applied Date: 05/08/2006 Applicant: SHAMROCK CENTER BLDG A Issue Date: Receipt No.: R06 -00627 Payment Amount: 43.31 Initials: 3EM Payment Date: 05/08/2006 03:15 PM User ID: 1165 Balance: $203.22 Payee: CONNIE L HARDIN TRANSACTION UST: Type Method Description Amount Payment Check 10369 43.31 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES RECEIPT Account Code Current Pmts 000/345.830 43.31 Total: 43.31 5218 05/08 9716 TOTAL 43.31 doc: Receipt Printed: 05-08-2006 Project: // // � G s / 3 /u Type of Inspection: D6 1 l I I>, Addres / SO Date Called: Special Instructions: Date Wanted: nn / �J' /) // _pa.,,m�.- /—V�j - Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION Mtt -of/ PERMIT NO. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: Approved per applicable codes. El Corrections required prior to approval. // Date` r • El $5 *� INSPECTION F E REQUIRED. Prior to inspection, fee must be pal. at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: Project: c-.y K . H d a'cc P Type of Inspection: A-ec h lC Address: Date Called: 10113 l Special Instructions: Date Wanted: 1 0/ 1 7► JCr am. 3 Requester: "— t" Phone No: 2ti8 C I - 7 0 Inspector INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION d , t 4 PERMIT NO. 6300 Southcenter Blvd., *100, Tukwila, M\ 98188 A206)431.3670 Approved per applicable codes. Corrections required prior to approval. C OMMENTS /) Ue-4-pi- c -G -•1a -t7% rl�l 1.7,4Y, Date:�� J/ / ~ oe 0 $58. REINSPECTION EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Calttosechedule reinspection. Receipt No.: 'Date: 10 -03 -2006 PEGGY PEEL 4600 S 134 PL SEATTLE WA 98168 RE: Permit No. M06 -091 4600 S 134 PL TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division: Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206431 -2451 to schedule for the next or final inspection. This inspection is intended to determine-if substantial work -has been accomplished since issuance of the permit or last or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve . one or more extensions of time for - additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 11/11/2006, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, rshall, Permit Technician ac: Ot4 r Permit File Flo. M06 -091 City of Tukwila Steven M Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 - 431 - 3665 ACTIVITY NUMBER: M06 -091 DATE: 05 -08 -06 PROJECT NAME: SHAMROCK CENTER, BLDG A SITE ADDRESS: 4600 S 134 PL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: 6 Build g Divisiion "�� W Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: "PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP 60 5�q Fire Prevention Structural ❑ Incomplete ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU NG: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documentshouting slip.doc 2 -28 -02 DATE: DATE: Planning Division Permit Coordinator ❑ No further Review Required DUE DATE: 05-09-06 Not Applicable ❑ DUE DATE: 06-06-06 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License HOLADPI379NO Licensee Name HOLADAY PARKS INC Licensee Type CONSTRUCTION CONTRACTOR UBI 578004089 Verify Workers Comp Premium Status Ind. Ins. Account Id Business Type CORPORATION Address 1 PO BOX 69208 Address 2 City SEATTLE County KING State WA Zip 98188 Phone 2062489700 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/21/1983 Expiration Date 9/3/2007 Suspend Date Separation Date Parent Company Previous License 1101ADPF376NO Next License Associated License Look Up a Contractor, Elects ''n or Plumber License Detail ■s UWQL4fltl. fltlUSUI � "T T Home � Safety Claims & Insurances Workplace Rights Trades @ Licensing I Find a Law or Rule Get a Form or Publication Look Up a Contractor, Electrician or Plumber Printer Friendly Version {General /Specialty Contractor +A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. License Information Topic Index I Contact Info Page 1 of 3 https: // fortress .wa.gov /lni/bbip/Detail.aspx ?License= HOLADPI379N0 05/15/2006 BUILDING ECONOMIZER BUDGET TAG TENANT ANTEi1 SERVED TOTAL MBH - ECONOMIZER ECONOMIZER TYPE i METH NON ECONOMIZER MIBH po v a O OOOCOCOp p 4, O OOO O OOOO • - N M 1f MI D f. 03 CP • ■ y IttittWAIT, 2eee § Ilniath 000000000, n0 888888888 $1 'd. ARSIDE AIRSIDE ARSIDE ' ARSIDE ARSIDE ARSIDE AMIDE AMIDE ARSIDE 888828288O0o TOTAL FOR BUILDING 668.9 540 128.9 TOTAL NON - ECONOMIZER LOAD ALLOWED 240.0 IMETTUH TOTAL NON - ECONOMIZER LOAD USED 1289 IIBTIJH TOTAL NON- ECDNOIRZER LOAD AvNLJN3 E 111.1 METTUHI TOTAL NON-E LOAD AVAILABLE 9.3 TONS Note: 1997 MrSEC (or SEC) Section 1433: Non-Economizer Capacity shag not excised 240 M BH or 10% 01 the aggr egate cooling with economizer capacity, whichever it greater. • 1 ELECTRICAL COORDINATION NOTES ELECTRICAL COORDINATION 1. WHERE MDICAITD ON EQUPMENT SCHEDULES, THE EQUIPMENT COMES COMPLETE FROM THE FACTORY WITH MOTOR CONTROLS AS REQUIRED. ELECTRICIAN SWILL PROVO( SERVICE AND A DISCONNECT PER CODE, AND DO AIL POWER VI RING, INCLUDING CONNECTING TO EQU P ENE. 2. %IM RE INDICATED ON EQUIPMENT SOIEDLAES, THE EQUIPMENT REQUIRES HELD NSTAIED MOTOR STARTERS. ELECTRICAL CONTRACTOR SHALL FURNISH MID NGTN1 MOTOR STARTERS (OR CONTACTORS MERE NDiCATED), PROVIDE SERVICE MD DISCONNECT PER CODE. MD 00 ALL POWER WRING. MCLUAWNG CotN1ECTi IG TO EQUWMIENT. MOLDING COL CIRCUIT SHALL BE POMIERED BY ELECTRICAL CONTRACTOR (120 VOLT /1 PH. UNLESS INDICATED OTHERWISE). N1 STARTERS SHALL BE PROVIDED WiTH H-O-A SWITCH: SEISMIC RESTRAFING NOTES SEISMIC RESTRAINING NOTES (U.B.C. SEISMIC ZONE 3, WPM SEISMIC HAZARD LEVEL B) 1. ANY EQUIPMENT MOUNTED RMGDLY TO DE BUILDING SiRUCTURE SHALL NOT REQUIRE ADDITIONN. SEISMIC RESTRAINT. 2. RESTRAIN ALL RECTANGULAR DUCTS 6 SQ. FT. OF AREA AND URGER AND ALL ROUND DUCTS 28' IN DIAMETER AHiD LARGER. RESTRAINTS SHAM OCCUR 30 FEET 0.C. MAXIMiUM MO SHALL BE INSTALLED AT EVER! DUCT TURN AHD AT THE 00 OF THE DUCT RUIN. SEE MD INSTALL RESTRAINTS PER SWCNA► SEISMIC RESTIVIMNT MANUAL ,3. ALL CEU NG MOUNTED DIFFUSERS SOLI. HAVE SIRES (16 GA.) ATTACHED TO THE MOVE FLOOR SLAB OR STRUCTURE. SAFETY ORES SHALL BE LEFT PARWILY SLACK ALTEJRMATE METHOD SIMI.L BE TO ATTACH DIFFUSERS 10 T-ENAR GRID MTH SCREWS,, RIVETS, oR CLUNG CUPS FOR TETRf/NN3 NEIGHING LESS 1WW 20 POUNDS. GENERAL NOTES 1. ALL TRADES TO LEAVE 36' CLEARANCE 14 FRONT OF MECHANICAL EQUIPMENT ACCESS PANELS FOR SERVICING. 2. CUTTING, FRAMING, PATCHING AND PAINING OF WALL, CEILING AND FLOOR OPENINGS SHALL BE BY GENERAL CONTRACTOR. THIS INCLUDES OPENINGS THROUGH AREA SEPARATION MULLS. 3. ROOF CURBS, FIASHINGS, SLEEPERS, PITCH POCKETS, AND CUTTING AND PATCHING OF ROOF OPENINGS SHALL BE BY GENERAL CONTRACTOR 4. ROOF CURBS. SLEEPERS, AND CANT STRIPS TO BE BUILT AND FASTENED TO THE ROOF BY GENERAL CONTRACTOR. CURBS TO BE CONSTRUCTED ACCORDNG TO SIZES PRO■OED BY HOLIDAY- PARKS' HELD MECHANIC. SHIM AS REQUIRED TO WAKE ROOF CURBS AND SLEEPERS LEVEL TOP OF CURB MUST BE TRUE (FLAT) TO PROVIDE AN ACCEPTABLE SEALING SURFACE. MNW(MUM ALLOWABLE DEVIATION FROM LEVEL OR FLAT SWILL BE 1/4' IN 10'. ROOF CURBS IUD SLEEPERS MUST BE SECURELY FASTENED TO STRUCTURAL SUPPORT MEMBERS. 5. ROOFTOP HEAT PUMP N0. HP -1 ARE FURNISHED WITH FACTORY CURB REQUIRING INSULATION AND CANT STRIP BY GENERAL CONTRACTOR. CURB SHALL BE ASSEMBLED AND SET N PLACE BY MEOW ICJ. CONTRACTOR. LEVELING, TRUING. AND FASTENING OF CURBS TO ROOF STRUCTURE SHALL BE BY GENERAL CONTRACTOR. TOP OF CURB MUST BE T RUE ( FLAT) TO PROVIDE AN ACCEPTABLE SEATING SURFACE MA)OMUM ALLOWABLE MUTTON FROM LEVEL OR FLAT SHALL BE 1/4' 14 10'. ROOF CURB MUST BE SECURELY FASTENED TO STRUCTURAL SUPPORT MEMBERS. 6. FINAL PANTING OF GRILLE'S, REGISTERS, AND DIFFUSERS, AS MAY BE REQUIRED BY ARCHITECT, SHALL. BE DONE BY GENERAL CONTRACTOR 7. GENERAL CONTRACTOR iS RESPONSIBLE FOR TEMPORARY HEAT DURING CONSTRUCTION. 8. UNIT WEIGHTS MD LOCATIONS HAVE BEEN COORDINATED MATH ARCHITECT AND STRUCTURAL ENGINEER TO DETERMINE BUILDING STRUCTURAL. ADEQUACY. F R IS NECESSARY TO RELOCATE A UNIT, NOTFi' HOLIDAY- PARKS' ENGINEERING DEPARTMENT FOR RE- COORDINATION. 9. BEAM PENETRATIONS ARE REQUIRED FOR DUCTWORK CLEARANCE AND FUTURE TENiNNT IIPROVEMENT. GENERAL CONTRACTOR 5 TO PROVIDE ALL BEAM PENETRATIONS PER HOLIDAY- PARKS' ORAiNNGS AND HELD WRONGS AS APPROVED BY THE STRUCTURAL ENGINEER. 10. N NO INSTANCE SHALL OTTER TRADES HANG OR SUPPORT EQUIPMENT. COUNG HIES. UGHT FIXTURE HANGERS, ETC., FROM WPC EQUPMENf OR DUCTWORK. 114a1Wiggsral‘aviarniaitbilaill146.' 40§4R• PROJECT COMPLETION NOTES 1. DRAWINGS: A. UPON PROJECT COMPLETION ISTAUIRS SHALL PROVIDE ACCURATE AS -BUILT REDLINES TO H -P ENGIiEERING DEPARTMENT FOR INCORPORATION INTO ELECTRONIC FILES. REDLNE DRAWINGS MALL INCLUDE: 1. ALL DIFFUSERS SHOWN N FINAL EXACT LOCATIONS. 2. ALL VAV BOXES AND SMALL L FANS SHOWN WITHIN 12" OF ACTUAL LOCATIONS 3. ALL LARGE EQUIPMENT SHOWN 14 EXACT LOCATIONS 4. ALL DUCTWORK SHOWN WITHIN 12• TO 18' OF ACTUAL LOCATIONS 5. ALL PIPING SHOWN WITHIN 12' OF ACTUAL LOCATIONS 6. ALL DIMENSIONS SHOWN ON ENGINEERED DRAWINGS TO BE REVISED TO ACTUAL. 7. ALL ELEVATIONS AFF SHOWN ON ENGINEERED DRAWINGS TO BE REVISED TO ACTUAL 8. ALL RAC AND PiPNG DEVILS REVISED PER ACTUAL NSTALUTION AS - BUILTS SHALL BE RETURNED TO E$GINETRNG WITHIN 5 DAYS OF SCHEDULED COMPLETION DATE. RECORD DRAWINGS OF THE ACTUAL INSTALLATION WALL BE PROVIDED TO THE BUILDING OWNER BY THE AGREED UPON SCHEDULE BATES. 2. MANUALS: A. OPERATION AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER BY THE AGREED UPON SCHEDULE DATES. THE WMJAK SHILL NCL.UOE, AT A MINIMUM, THE FOLLOWING: 1. SUBMITTAL DATA STATING EQUIPMENT SIZE MID SELECTED OPTIONS FOR EACH PECE OF EQUIPMENT REQUIRING MANTEKVICE. 2. OPERATION AND MAINTENANCE MANUALS FOR EACH PIECE OF EQUIPMENT REQUIRING WMNTENWNCE, EXCEPT EQUIPMENT NOT FURMSHED AS PART OF THE PROJECT. REQUIRED ROUTINE MAINTETNANCE ACTIONS SWILL BE CLEARLY IDENTIFIED. 3. NINES N40 ADDRESSES OF AT LEAST ONE SERIACE AGENCY. 4. HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION, INCLUDING WIRING DIAGRAMS, SCHEMATICS, AND CONTROL SEQUENCE DESCRIPTIONS. DESIRED OR RE1D DETERMINED SET POINTS SHALL BE PERMMIENTLY RECORDED ON CONTROL DRAWINGS AT CONTROL DEVICES, OR, FOR DOTAL CONTROL SYSTEMS, N PROGRAMMING COMMENTS. 5. A COMPLETE NARRATIVE OF HOW EACH SYSTEM IS INTENDED TO OPERATE MNCLUOING SUGGESTED SET P01tNTS. (SEQUENCE OF OPERATIONS) 3. SYSTEM BAUWCIlG: A. GENERAL: WPC SYSTEMS SHALL BE BALK ED IN ACCORDANCE WITH GENERALLY ACCEPTED DOWERING STANDARDS. MR MIND WATER FLOW RATES SHALL BE MEASURED AND ADJUSTED TO DEl.NER FiNAL FLOW RATES WITHIN 102 OF DESIGN RATES. A WRITTEN BALANCE REPORT SHALL BE PRONGED TO THE OWNER BY THE AGREED UPON SCHEDULE DATES. B. AR SYSTEM BALANCING: MR SYSTEMS SHALL BE BALANCED IN A WANNER TO FIRST MINIMIZE THROTTLING LOSSES THEN. FOR FANS WiTH SYSTEM PoWETR OF GREATER IRAN 1 HP, FAN SPEED SHALL BE ADJUSTED TO MEET DESIGN FLOW CONDITIONS. ADDITIONAL REQUIREMENTS INCLUDE: 4. SYSTEMS COMMISSIONING A. SIMPLE SYSTEMS: FOR SIMPLE SYSTEMS. AS DEFINED N SECTION 1421, AVID FOR WAREHOUSES AND SETrIHEATED SPACES, HNAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT MID SYSTEMS ARE CAVE RATED, ADJUSTED AND OPERATE M ACCORD WITH APPROVED PLANS AND SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE N ACCORD WITH APPROVED PLANS AND SPECIFICATIONS. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED MO FLED MATH TIE OMER BY THE *GREED UPON SCHEDULE DATES. B. OTHER SYSTEMS: Ni. OTHER HVAC CONTROL SYSTEMS, AND OTHER AUTOMATICALLY OONTROLLS SYSTEMS FOR WHICH ENERGY CONSUMP11ON, PERFORMNNCE. OR MODE OF OPERATION ME REGULATED BY THIS COOS. SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, EQUIPMENT MD SYSTEMS PRE CAUBRIAED. ADJUSTED AND OPERATE IN ACCORD WITH APPROVED PLANS AND SPECIFlGTIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE M ACCORD ViM APPROVED PLANS AND SPECIFICATIONS. C. DOCUMENTATION: THE WITNESS TEST CHECKLIST SHALL VERIFY THE FOLL.OI NG FOR EACH TEST: 1. EQUIPMENT WO SYSTEMS TO BE TESTED. INCLUDING THE EXTENT Cr WPM TESTS, 2. FUNCTIONS TO BE TESTED (FOR MAPLE CALIBRATION. ECONOMIZER CONTROL, ETC.), 3. CONDITIONS UNDER ! 'Mi THE TEST SHALL BE PERFORMED (FOR E)UMA E TINIER DESIGN CONDITIONS, FU U. OUTSIDE AYR, ETC), 4. MEASURABLE CRITERIA FJR ACC P1ABLE PEIRFORYMKE. 5. COkaiSSIOiSID REPORTS A. PREUMMNARY COMNMwIiSIONING REPORT: A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES i io RESULTS SHAM BE PREPARED. THE PRELM MI1RY REPORT SHAM DEM'FY: 1. DEFiCENCIES FOUND DUR IG TESTING REQUIRED BI' THIS SECTION INCH Wit NOT BEEN CORRECTED AT TIE THE OF REPORT PREPARATIN FWD THE ANTTCPATED BATE OF CORRECTION. 2. OEFERRED TESTS WHICH CJWNOT BE PERFORMED AT THE TIE OF REPORT PREPARATION CUE TD CLIMUC COIOiTi0NS. a CLIWIC CONDITIONS REQUIRED FOR PERFORMNICE OF THE DEFER= TE515, MD THE ANflCPATTDD DATE OF EACH DEFERRED TEST. a FINIAL COMNISSIONING REPORT A COMPLETE REPOitT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED NO FLED WITH THE OIRM BY DE AGREED UPON SCHEDULE BATES. SHEET METAL NOTES 1. DUCT SIZES INDICATET) ON PINS ARE NET IGS OE DIMENSIONS. A CALL -OUT SUCH AS 12' X 12" /SL MEANS A 14' X 14' SHEET METAL DUCT 1111114 1" SOUNOL.WER, MUG A NET INSIDE OMIEiNS10N OF 12' X 12'. 2. DUCTWORK SHALL BE CONSTRUCTED TO a1ENSIONS INDICATED ON RMS. THE TOLERANCE OF THESE DIMENSIONS SHALL BE AS SPECIFIED 14 HOMO-PAWS, INC. SHOP STANDARDS MANUAL. LENGTHS, ONO CRITICAL DIMENSIONS BETWEEN DUCTWORK AND OTHER BUILDING /SYSTEM ELEIrEN1S ARE NOICATED SERE A LOCATION OR DIMENSION SCALED FROM THE DRAWING MILL NOT BE ADEQUATE. THE TOLERANCE OF CRITICAL DIMENSIONS, F NOT INDICATED. SMALL DEFAULT TO THAT OF THE VISTA IJ NG MECIANIC'S MEASURING DEVICES. SCALED LOCATIONS OR DIMENSIONS ARE NOT SUBJECT TO TOLERANCE GUIDELINES. 3. THESE PLANS HAVE BEEN COORDINATED WTTIt THE ARCHiTECTURiII.. STRUCTURAL. SPRINKLER AND ELECTRICAL DRAWINGS. ANY CHANGES N THiS LAY -OUT MUST BE REViEiMED BY HOADAY- PARKS' ENGINEERING DEPARTMETIIT. 4. FINISHED COLNG HOGHT N OFFICE AREAS WILL BE 8 6" ABIG.'c FINISHED FLOOR (AFF) TO BOTTOM OF CETLWNG. 5. ROOFTOP PACKAGED Mt COiDiTIONNG SYSTEMS' DUCT CONSTRUCTION SHALL BE AS FOLLOWS: a. VT•RTICAL OROPS FROM ROOFTOP A/C UNITS SHALL BE RECTANGULAR GALVANIZED SHEET METAL WITH 1' SOUCLIER FABRICATE AND INSTALL PER SMArCNA 1/2' PRESSURE CLASSIFiCATION. b. SUPPLY MR DISTRIBUTION DUCiWONRK FROM VERTICAL. DROPS 10 DIFFUSER KNOUTS SHALL BE 1' THICK. U.L USTED, CLASS 1 FIBERGLASS DUCTBONARO EXCEPT WHERE UNED SHEET METAL 5 INDICATED. FABRICATE AND INSTALL PER SWAM 1/2' PRESSURE CIASSFiGATION. c. RUNOUTS TO DIFFUSERS SHALL BE LOW PRESSURE INSULATED FLEX DUCT (MD RIGID ROUND DUCT INHERE INDICATED). USE U NI NSUUA1ED FURNACE PPE FITTINGS WHERE FITTINGS ARE INDICATED IN RIGID ROUND DUCT. FLOC DUCT SHALL BE LM/TED TO 8 FEET AND TWO 45 DEGREE TURNS. d. WHERE RETURN AMR IS DUCTED, RETURN AIR DUC' WOlRK SHALL BE THE SAME AS FOR SUPPLY. 6. MATERIALS: a. SOUNDLIitER (INDOORS): 1' THICK 1 -1/2 LB. DENSITY FIBERGLASS DUCTLINER MATH BLACK MAT FACING. SCHULLER- MA1MLLE ATE UNACOUSTIC STA DARD , OR OMENS CORNING 'AEROFLEX PLUS". (MINIMUM !INSTALLED R- VALUE = 3.3) b. 90UNNOLIER (OUTDOORS): 2' THICK, 1 -1/2 LB. MISTY FIBERGLASS DUCTUMER WITH FLACK MAT FACING. SMILER-MANVILLE 'ERWCOTE uNACOUSTTC SUN0ARO', OR OMENS CONING 'MROFLEX PUS'. (Imam INSTALLED R -VALUE = 7.0) c. LOW PRESSURE INSULATED RD( DUCT: THETAS X d. DUCT INSULATION (INDOORS): 1 -1/2' THICK 3/4 LB. ODOTY FIBERGLASS MTH F.S.K. VAPOR BARRER JACKET. (MINIMUM INSTALLED R- VM.LUE = 3. PROJECT COMPLETION REQUIREMENTS OFF M' BHP 600 B OO BOU sr CB MO C �L OB aPR Olt O . EC. aft ESP EXR FC LiL R OR FML ML RIT ABC ME WISHED FLOOR ACCESS PMQ BACK IRA LIMPER AMA E HORSE POM M ROATOM OF oncr MOrrom OF UNIT BYPASS 1ist COINIFR -eamc® B+nc MR WIPER aura comecritoommown OLICIBOARD ORP9t oitNl EICH MIMS AR TBP EMMA as oaa.�claR oesusr mom RDc COIME ON FINE ONMlE1t FUMED RDOR LOB RRL LOW IMPS RAM MN s - Ra 011 mom ow OR 1rP HVAC ABBREYIATiONS MIME oMs GENERAL C MIRACIOR RISK 011E6i0II/01111313 MUM LRAM * 1BP swam ctaait MM>IAOTY O at APP DIRJE 1011111111Y CLOSED ION N IDMMGT IMIMIMLLY OBI IIOM N OT l0 SOME O MSDE AR OPPOSED & I VIPER OU SME 011D6I01 PRIM POUNDS PER SI MILE M O N RISE MEAD - Nit SUPPLY BR so 1U OU 91ffMETAL SA1K PI SSE 111111114 MKS VOLUME WIPER AMR MI IMP QE: a,a 1151111110111) • • --T • L.OT -FLIP GFM • - RAG. 0 n *.e. A l CD/PD GFM xu x` GO/P GFM X 'W/P/F) X' X' GD/PF (SLAT- IiLETV D GFM •BLOT -III /P GFM S.S.R. S.S.G. LN.w.S.G RAIG./P. S.R.G. LN.W.R.G. LG. MUST GRILLE PLUMMY EGGCRATE WITH 1/2' x 1/2' x 1/2' CORE Tl1US MOM 50F - IORUEGER EG-5 0 O ER Ca T:6. O TA/P. - • ac . _ •a <" • .z=. -. ' :tip' i.,' #° -_ ..,..... ..>,;il• ... - ... MIST LOUVER GOD ODD KID GRLLES, REGISTER, DIFFUSER LEGEND NOTE NOTE: THE ' /FD' CALLOUT INDICATES A GRILLE MTH U.L CUISSIFiED RADIATION DAMPER TO BE INSTALLED IN RATED FLOOR /COUIG OR ROOF /COUNG ASmUES. USE RUSIQN YODEL CFO. INCLUDE THERMAL INSULATION BLAPMET FOR LAY -N T -BAR CLINGS. ALL SUPPLY DIFFUSERS ARE TO BE INSTALLED FIRTH A DFFUSER CAN w/ PERF 0M0ER, GENSCO REGISTER BOX W/ F FX COLLAR & OFF, MODEL. COLDC21 OR EQUN. CEiiNG DIFFUSER (LAY-P4 T-BAR CEXNNG) 4 CORE ADJUSTABLE, MNTH FILLER FOR 24' x 24' LAY-IN MOOUI.F TTTUS MODEL MOD, BORDER TYPE 3 - KRUEGER SERIES 1244, FRAME 23 (USE X'1 RUNOUT) CEILING DIFFUSER WiTH FIRE DAMPER (LAY-IN T -®AR CEILING) 4 CORE AAiUSTABLE, AIL STEEL CONSTRUCTION, RADIATION DAMPER SHALL BE RUSKIN MODEL CFD W/ THERWL INSULATING %WIT (USE x'i RUNOUT) COM DIFFUSER (RASTER CEIUNG) 4 CORE ADJUSTABLE. Y FRAME TTTUS MOOEL MCC, BORDER TYPE 6 - KRUEGER SERIES 1244, FRAME 21 CEILING DIFFUSER (PIASTER CEUNG) MTh FRE DAMPER SAME AS C.D. /P MATH RADIATION DAMPER AS NOTED ABOVE (USE x'* RUNOUT) CEILING DIFFUSER WiTH PERFORATED FACE (LAY -IN T-EVR CEILING) 4 CORE ADUSTiBLE. 1MTTII FILER FOR 24' x 24' LAY-N MODULE kRUEGER SERES 1244P, FRAME 23 (USE X' RUNOUT) (USE X' RUNOUT) SLOT DIFFUSER FOR LAY-14 mum iCEES -100 SLOT DIFFUSER FOR RATED LAY-IN COLIC WITH FIRE DAMPER TEMPMi ASTER FRO SLOT DIFFUSER (PLASTER GELLING) LEES K -100. FRAME OPTION I SLOT DIFFUSER WITH F1RE DAMPER (PLASTER MI NG) TEMPMASTER MODEL 1FD-F OR FRD-F FOR SURFACE MOUNTING SDEIWALI SUPPLY REGISTER DOUBLE DEFLECTION, HORIZONTAL FRONT BLADE'S, WITH 0.13.0. TITUS 1100E1 272RL 0.810. - KRUEGER NO0E1 880N 0.8.0. SAEWALL SUPPLY GRILLE DOUBLE DEFLECTION, HORIZZONNTAL FRONT BLADES TRUS MODEL 272RL - KRUEGER MODEL 880H LINEAR MALL SUPPLY GRILLE FIXED 15 DEGREE DEFLECTION BLADES KRUEGER MODEL 1515, FRAME 415. ALUMVIUM1 CONSTRUCTION RERIRUN AR GRILE PLUMMY EGGCRATE ICH 1/2" x 1/2' x 1/2' CORE TITUS 11000. 50F - KRUEGER EG-5 RETURN AR GRILLE (PLASTER CQmG) FIXED 35 DEGREE OEFLECTTON BUIDES MGR MODEL 580H SIDEiI OLL RETURN RXED 35 DEGREE DEFLECTION BLADES, N THOUT ORD. TRUS MOM. 350RL - KRUEGER MOOEL SBOH MEM MILL RETUFNN GRTIIE RXED 0 DEGREE DEFLECTION BLADES KRUEGER Ma 1500. FRAME 415 ALLUVIUM CONSRLUCTION RETURN AR CRUX (RASTER CDLPIG) HUED 35 DEGREE DEFECTION RA TAUS MODEL 35DiI. - ICRUEGER M00EL SAN EX IMUST REGLSIST FIXED 35 DEGREE °ERECTION BLADES 11116 MO EL 35063. O.B.D. - iaRUEGER YODEL MI 0.8.0. 'TRANSFER ME ALUMINUM exam V84 1/2' x 1/2' x 1/2' CORE 1TiI5 Mil 35CW - KRENER EG-5 1RANSFER GRILLE (PLASTER CERROG OR MO FIXED 35 DEGREE DIRECTO' BLADES 1i1US NOM 350111 - KRUEGER 1100EL SOON 4' SW1 NAlti LOUVER RUM MODEL EIF-375 51EEL = 81 COPISTRUCTION o 0 en Rig 4' STATIONARY IAAER WITH ONAIWILE BLADES DALIMIIMLZtD STEEL C NSIINX11D1 RISKIN Ma ELF -3750 CiV cif bulk nett WORT ARM Pt COO MUM aye MICK Me BAWER MUSK M IMMI RQ/A1, LOON. VELOCITY < 1500 FRI Rk51ll NOM B 2/*2, LOCAL VELOCITY < 2500 F1P11 MOM MODEL Mk LXN. LRCM < 3500 FF1M iiiiiiiiiiiIii Illoslame OW Is NMI Mlle amps Wynn* slam Mir sipping, at SOON 1111011m ad Ms m �. • • - •,• -, ► cy A. •".�+.r ^ °� AMA., . ,..:.o. ° 91i• - r. imparunit mama 11111111111111110 I101b .et momineavivt.i._ socittinsciova. sac " 1 • DANIS f C ,► 12'x12' 12'x1 SM 12/12 tY :tY 9wr f / I r � P 3824• eaL-1 I OW. MISIda ( sum mai. sameW NOM Ram ad calm Ammo dimem Ow■tsi±I IMs IoM Rir0=4.11.11 admigelt Me, 1 HVAC LEGEND DUCT UNDER POSITIVE PRESSURE DUCT UNDER NEGATNE PRESSURE TURNING VIES ELEVATION FROM FF.L EQUIPMENT IDENTIFICATION THERMOSTAT SENSOR CEILING OR NNLNE EXHAUST FAN 24" x 12' RETURN AR GRILLE W/SOUNOL8lED CAN SUPPLY AMR ARROW RETURN AR ARROW SPEED SWITCH: FISHED BY HOLIDAY - PARKS, INSTALLED BY ELECTR. CONTR. FLEXIBLE CONiNECTION DUCT HEATER WANLK VOLUME DAMPER MOTORIZED DJ ER BACK DRAFT DAMPER WOKE DETECTOR VERTICAL FIRE LIMPER HORIZONTAL FIRE DAMPER SMOiE DAMPER cameos SMOKE AND FIRE DAMPER SPIN-IN THE --OFF E VOLUME DAMPER INDICATES 14' x 14' 0.D. SHEERED/ RUH 1' SORDLMER (UM.). 12' x 12' NET LD. INDICATES UiILIED 12" x 12' S.M. DUCT INDICATES 12' : 12" LD. DUCTBQARD IIDiXLXES UNLINED 12 x 12' S.Y. DUCT MTH ROUTED %ROD RISE OR DROP M MEOW OF' 8.011 MORE DUCT MUTES RAT OIL CULT SPIN-M 10E -OFF & *TUNE DUPER WnHI RIGID ROUND FIBEIGIAIS DUCT NU WELD 6 111-0 • 5 NIF 6 11-2 6 11-3 6 •-•.1 • 11-5 SHEET INDEX • = nor acute IN I. IMIE =MIME LEiG NIBS MD NOES MST RD INK RAI SECOND ROM iII1C PLAN ROOF INIC MILS PUN Si HE RES APPROVED FOR CONSTRUCTION r iC = �Jr gas � :R 4 �f a. �e gt eimi - Ntr PErilkir 1 1 77615/76 PENDI4G ITY C APPROVAL m-O C gi t o 1 t Clip Wavle 1.1111111111111111111111111 -su �►i. - �. �+. • FAN SCHEDULE MTR EFF OUTLET ORIENT. ROTATION CW /CCW (29) VOLTS/ PHASE WGT. LBS. .� REMARKS FAN NUMBER TENANT AREA SERVED MAKE TYPE MODEL CLASS PERFORMANCE DATA HP VFD TAG CFM ' S.P. RPM BHP EF - 1 _ Holaday -Parks lst Fl Server Roorn GREENHECK UTILITY 3W8 -16 -5 - 1800 0.75 1184 0.34 0.5 - - UB CW 120/1 300 1,5.8 - - _ - - - - - - k - _ - _ - - - _ - - - - SPLIT SYSTEM CONDENSING UNIT SCHEDULE C.U. # MAKE MODEL DXFC SERVED ELECTRICAL SEER EER. WEIGHT (Les) REMARKS VOLTS /PH MCA CU -1 _ TRANE - TTB048 DXFC-1 i 230/1 30 1 0.5 - 250 1, 2, 4, 6, 7 CU -2 MITSUBISHI _ PUZA18NHA OXFC -2 208 -230/1 13 , 14.1 - 97 1, 4, 6, 7 .. • . .' LI1mIiIl m000.. 1 - : 7R1.11111111111•1 •1 j ffia g Y 3 00S %`" - 575'5756 M-S.1 2 HEAT PUMP SCHEDULE HTR. KW ELECTRICAL VOLTS /PH MCA HP f HP -1 ROOFTOP AIR CONDITIONING UNIT SCHEDULE AREA SERVED TRANE YCD060A4LOAB - A.C. # AC -5 AC -6 AC -7 AC -9 ee SERVER ROOM BASEMENT • MAKE TRANE MAKE TRANE MODEL YCDO60A4LOAA MODEL WCD036C TRANE YCD060A4LOAB - TRANE YCD060A4LOAA - NOM. COIL TONS TYPE COOLING TOTAL SENS. 39.4 25.0 E.A.T DB /WP TRANE YCD060A4LOAB - H1G CAP. 36.0 GROSS COOLING SUPPLY FAN PERFORMANCE DATA TOTAL SENS. CFM ESP RPM BHP MHP TRANE YCD060A4LOAB - 1200 FAN CFM PERFORMANCE DATA S.P. .67 1 WIRING AND DISCONNECT BY E.C. 2: LOW AMBIENT KIT PROVIDED AND INSTALLED BY REFRIGERANT PIPING CONTRACTOR. PENN P66 SERIES. 3: FASTEN TO SLEEPERS ON MASON TYPE "1M" WAFFLE PAD WITH BOLT ISOLATION BUSHINGS. 4: EER AND SEER RATINGS PER ARI 214 /240 -1989 5: OPTIONS INCLUDE CRANKCASE HEATER KIT. AND TSTAT. 6: LOW VOLTAGE CONTROL WIRING BY CONTROLS CONTRACTOR 7: HANG WITH MASON TYPE "HD" NEOPRENE HANGARS 8: HANG WITH MASON TYPE "DNHS' SPRING ISOLATORS WITH SEISMIC SLACK CABLING. :c :. _ _ c D._ 3`' V ;.. yl' = =D t _C+I► •r _'•ti_ CCti =:,_ w \: ?` CON? OLS CCNJ.AC' R ...,. .�•:� _ -- "fir : ��' 4r .. RPM MHP TRANE YCDO6OA4LOAA - - - - - _ _ - _ - h. Ally .34 D S :.;'•• E :',` 9' _.°. ��;:1 - .JE - '-'_ =VA =R -A. \� :' . A _ E- . - DEL. - 5;c., E" 04.C. SE 'E P'.7W< C NINET'ON BY E.C_ C _.- .� /4/ ..., ._� ♦�� �.:V- �..� -' ill. J:.. C:1.. .:_. •'�.'P.ti "'' PARA ""Z '. ; E_ ; r? =-,•t' CZ; ti '5 ?EQJI?ED. c a •,. �C _ '.SA _ A?= ; ' ; ` , rD a , : ItiG ° ECEP - ' - :JL.. SEE 2 SI"rccT M,"1 FOR TRAP 01E!v5to"!5 �• :; w" •J VAS-C\ '�E :`\ --= S= G 's ' A w .SE wi : Rs. \: w VIZt ' max _ % ._T ESL �';• \� _ S. OSA 6.0 208v/30 RELIEF FAN PERFORMANCE DATA CFM ESP RPM • f.V . - - 1. '� , 35.8 565 10.5 BHP 111111111111111111111- MHP SUMMER sve SEER. 11111111111111111111111 SUPPLY AIR SMOKE DETECTOR SHALL BE FACTORY MOUNTED. FIRE LIFE SAFETY CONTRACTOR SHALL INTERLOCK SMOKE DETECTOR TO AC UNIT AND FIRE ALARM SYSTEM. OPTIONS INCLUDE. GFI OUTLET, SEPERATE 120 VAC POWER OUTLET BY E.C. SUMP DRAIN TO BE INDIRECT CONNECTED TO WASTE BY P.C. DOMESTIC COLD WATER CONNECTION W/ REDUCED PRESSURE BACKFLOW PREVENTOR PROVIDED AND INSTALLED BY P.C. OPTIONS INCLUDE, 100% 0.A. DRY BULB BASED ECONOMIZER AND MECHANICAL COOLING ARE CAPABLE OF OPERATING SIMULTANEOUSLY. OPTIONS INCLUDE, FACTORY CURB. OPTIONS INCLUDE, CONTROLS CAPABLE OF SUPPLY AIR TEMPERATURE RESET. OPTIONS INCLUDE, MOTORIZED OUTSIDE AIR DAMPER TO CLOSE DURING NITE SETBACK. OPTIONS INCLUDE. OUTSIDE AIR MONITORING. 100% ECONOMIZER, DOWNFLOW SUPPLY AND RETURN, 507.. EFF. FILTERS, VARIABLE FREQUENCY DRIVE FOR RELIEF FANS, VARICONE MODULATION ON SUPPLY FANS, DISCONNECT, SINGLE POINT POWER CONNECTION. 90 DISCONNECT PROVIDED AND INSTALLED BY E.C. 1� OPTIONS INCLUDE OVERSIZED MOTOR 11 SUPPLY AIR SMOKE DETECTOR SHALL BE PROVIDED AND INSTALLED BY M.C. . F /L /S CONTRACTOR SHALL INTERLOCK SMOKE DETECTOR TO AC UNIT AND FIRE ALARM SYSTEM. IPLV MINIMUM OSA QTY 2 WINTER FILTERS UPPLY ELECTRICAL TEMP. 1111111 01111111111111 - 11111 SIZE 20X25X1 eve 11111 11111111111111 .,r REMARKS MFS WGT. (lbs.) EER. SEER D.X. FAN COIL SCHEDULE (SPLIT SYSTEM) L., : \ OXFC -2 REPRO RV • YA'SUBISH _ PLM18M AAA v UN CU-2 Eel �= 75/62 :.:J..�• w-, Z '5 - - 18000 8'TU'1 SENS. 32 ',DO B'U C.V 16 FAN OA C ERFORUANCE ESP 0.55 • B ATA RP‘1 . 75 ,5 EL EC'R HzAT <'R ICAL VOLTS /P'. 23C» 208/230/1 MCA 4 .2 1 SIZE FILT RS WE CHT 2X 53 REIAA.RKS 2.3.4.6.8.' 1 t 2,3,4,6.e.11 FILTERS QTY SIZE REMARKS . wiRnV /Vr V�J�.VVCI� DT C.V. 2: MANUAL STARTER W /OVERLOAD PROTECTION SHALL BE PROVIDED AND INSTALLED BY E.C. 3: AUTOMATIC MOTOR STARTER WITH HOA SWITCH SHALL BE PROVIDED AND INSTALLED BY E.C., COIL CIRCUIT POWERED BY E.C., COIL VOLTAGE TO BE 1 20V. 4: 7 -DAY PROGRAMMABLE T -STAT SHALL BE PROVIDED AND INSTALLED BY CONTROLS CONTRACTOR 5: LINE VOLTAGE (120V) T -STAT WITH TEMPERATURE RANGE BETWEEN 60 AND 100 DEG. F SHALL BE PROVIDED BY M.C. AND INSTALLED BY E.C. 6: INSTALL ON SIESMIC SPRING ISOLATORS MASON MODEL SSLFH OR EOUN. 7: HANG WITH SPRING ISOLATION MASON MODEL W/ SEISMIC SLACK SPRINGS 8: HANG WITH NEOPRENE ISOLATORS MASON TYPE HD. • balm Oita sacall101116%. S•41 OMMIIIINI YAW DAMS • dal Imo • REL rE;tr',- CU' _ CO PL_ a.;a ! r 'cr. r =- . .•....,.. 1* PEM»G TY APPROVAL APPROVED OON:4Ti�JC110N improok amis 128bM51 MAW • 1" 41 5/5 SECOND FLOOR HVAG PLAN /22 1/46 1 P.O. OA 0M01 Job number: 1286 HOLADA 0 1. 134th Rosa Ow molt r'' RYmars 4 068 Y -PARK INC. �� WA 08188 248- goo I>�ATE �►� UE� WHINIER: 7 40 Its : �, " ` Mb ' "' .. ....NOON ; ....... . �� „, I xis OFF EPPA8910N SHAMROCK (U I LI NCB A) 4600 SOUTH 134TH 'LAGS TU K W I L A, WA 4 81 S 6 wales , ve i-o T T , � , '? .�.. ;, • . ©a© anpls�sersds DM3 /GLE approved: o wns t dr PAT 1R7 11 � t1lQt � tf. i� 4 1 • 4 • I 1 ' fr f; i A ir • • Y 1 M/to 1$.41144 It10 t ! I , 10 • 1 j 1 . 41 s 4-r7T 1— 1 i YJ• r-r r7-11' • '61 4 /'.: Y.. H.•t�sa�,!{i!'w'!wfs'r.+�";T. i I I i/f. r tl.• j.'\ R.- ‘,117 N �! _ �.. r.. - :. . • •• .."-`4:', "'- ' -�, i 1I , i i i lI 1 ._ (� - � t- . . - - -1 -- . 1 ±'' I .. t11— -1 - -- T - - - .._ - _ IMO E=3 oi ,.I I 1-. -- . , 1 _ , l .. .rte ".�.. _ - -- ^�: �-« __ +� ••�� _ 1 _. .. . 7 Mir �� FE EZ ll P[ ;, ; 8x 2 DB ( �• a�unn�a r o= liat,..1 �� j_ _ m. t_- ,.. . F ,.a i d, ,R :_� _ -_ � 'cam- _y- �-� :: 0 R� SIC , 1 . ) r 1 ■i /� 1 I / I ' ' , r i1► �I}. L '' ��"" 1 I , �1 h _. � i 1 11 � 1 J ` *'l ( i 1 is *fl I J I ! ' ���il %� 111 1 , *V 1 ( 1 �. ( 1 f �i_ I FA 111■1: ' .-_ _ftwrglt if I i .•:•1 ! i i. 1,,f it .X I " r I i I I jl �1� "�•.M 4,a.T r_ a2 ter_ 1 ' II •+ t\4 I ID .. 1 t // -,; 1 �� 1 r ^.} ..,s�.7. ._ I __ + 1__ . i _ .. .. nr•a• � �' '� w.- l•r_rt" �. r..r � -�� Ie .�_. •_. .ti- -: r.- . . r, : _. .LSD +- .._ I 1 ? t I! I 1 f 1 11 C7 1 •._ 11.1 l I I:al�i I l, : i aim 11 1I I 1 g . ► 1 p • 1 1 ' - r; - I ( Ij i► it '1 ) / tN? 4D / / --00fti:-...4•...; 401•••mia004111101111411^01. — - _ 30'XI2 DN -4 I Ac-i I I - V2" ON - r _ - r - - .7 Tr 1 77777 77,!.:" 7 - 36 'XIC Psl • SLEEPERS BY G.C. icu -1 1 36"X10"/I•SL ON 3CrXr2 t. DN IgrX10'/I"Si. DN - 1/2 • 3/4 3/4 lAc-4 BUILDING 5 ROOF I-1VAC PLAN Scaler = 1 kc lAc-71 50 DIT 3/4 1 3/4" 3/4 3/4 39"X11"/I'5L ON 33"X14 ON 4 /- 3/4' i 50 DN L _ B ON I • >< ••-• j 3/4' 11.1%,7111 3/4' TYPE 13' VENT TO 3' ABOVE ROCF 4 DN • • Z Pc—i l6eX9•/I•SL ON 18•X9 ON PWSSURE REGULATOR 1; : 3/4' 10-1 OD FACTORY CNIME.Y . TO 2 ABOVE 14 PARAPET WALL :t t' GAS 1 I c45 catiect, TO FIREPLACE OWNING )(REF DATES Ind= *mkt eider A1113111EGIIIRAL SSG - AIM1211111CIIMAL 11 RE. CWE CON:- LA fiallW tri"1 hie • Aat---0 • 4 rig 1111 d .1 “WisIsre 5/05/0b PENANG CITY APPROVAL APPROVED FOR coNsTRucTioN tuft worm 2861s-13 M-3 1 CA • J.1 • . 416ift 14.: .i.kieitillialtragallEet FASTENER SCHEDULE EQUIP. SYM. UNIT DIMENSIONS WEIGHT #OF 16GA STRAPS #OF 10x1 FAST., PER STRAP INSIDE OF CURB DIMENSIONS {. w H LBS L W H WEIGHT 80 HP -1 83.125 46.625 33.5 565 10 10 77.625 43.375 14 EQUIP. H X SIZE HP -1 4 2 3/4" " DXFC -2 2 1 I 3/4" eri TOP OF CURB MUST BE LEVEL t FLAT (SEE NOTES I t 2) 2x6 WOOD BACKING BY G.G. lb GAUGE ROOF CURB ---"" (BY A/C MF APPROXIMATE EDGE OF ROOF OPENING - STRUCTURAL MEMBER BY G.G. NOTES: SEE STRUCTURAL DRAWINGS I. GENERAL CONTRACTOR SHALL PROVIDE SHIMS AS REQUIRED TO MAKE CURB LEVEL. MAXIMUM ALLOWABLE SLOPE 15 I /4" PER 10'. 2. TOP OF CURB MUST BE TRUE (FLAT) TO PROVIDE AN ACCEPTABLE SEALING SURFACE. 3. ROOF STRUCTURE, ROOF DECK, INSULATION, CANT STRIP t BUILT --UP ROOFING BY GENERAL CONTRACTOR. 4. STRUCTURAL MEMBERS MUST NOT INTERFERE WITH ROOF OPENINGS. 5. FASTEN ROOF CURB SECURELY TO STRUCTURAL MEMBERS. Q STRUCTURAL ENGINEER TO SPECIFY (M DETAIL -- GURS WITH SEISMIC RESTRAINT SCALE: NONE (ACURBSR - 10/5/'4 HP UNIT - 2" WIDE x I_bgo 5EISMIC RESTRAINTS QUANTITY AND CONNECTION PER TABLE BELOW No. 10x5!8" SCREW SEAL t MAKE WATERTIGHT STOP ROOFING FELT BEFORE CURB LIP SHEETMETAL FLASHING INSTALLED OVER ROOFING FELT. (BY MECH.) NOMINAL 2" RIGID INSULATION (SEE NOTE 3) BUILT -UP ROOFING (SEE NOTE 5) CANT STRIP (SEE NOTE 3) (SEE NOTE 5) ROOF DECK • • ( L7ETAIL - CONDENSATE DRAIN 42 SGALE: NONE CD v t • . A111m1 ..his - i11C. iaiK's:+c EQUIPMENT UNION r SCREWED TEE r PLUG H it P -TRAP IS "/FT SLOPE POS. PRESSURE TRAPS H= I ", X= CASING STATIC PRESSURE + I" NEC- PRESS Dgm5 H =I"+ CASING STATIC PRESSURE, X =I /2H HP UNIT HAS TWO CONDENSATE DRAIN GOMECTIOI8, OPE PER SIDE. SOLENOID VALVE (BY REFER CONTRACTOR). SEE NOTE 7. REPLACEABIE CORE FILTER DRIER. SEE NOTE 9. PRIMER RISER/VENT LIP 6" AE3OVE I QUIPMENT CONN. T REQUI RED ON HORIZONTAL LESS THAN 10' -0 "J SIZE AS SCHEDULED SIGHT GLASS 03Y CONTRACTOR 000 NOT USE OETERI E F SYSTEM 6 PROPERLY CHARGED) 1. REFRIGERANT PPMG TO BE TYPE 1" HARD ORM COPPER ACR TUI3MG NMI WROUGHT COPPER mum A!O SILVE)t- SOL.DETED OR BRAZED JOINTS. 2. 601A1E ALL REFRIGEli>AIR IJE5 FROM THE B tan. 00 NOT SECURE 1HE LINE'S RIGOLY TO THE BMOC AT ANY PINT. 1 PITCH THE HORIZONTAL RUNS OF THE S ICTON U!E MIRY RON THE CONDDISiG LMT A WARM OF 1 /2" PER 1O FEET OF PPE LEDGTH. 4. INSTALLER SHALL USE A ORr !MOGEN RACE MO also G ALLlDT MEN BRA2MG THE FIELD LNE TO THE COPPER FACTORY common. F1011 CRY MTRON INTO EITHER VALVE PRESSURE TAP PORT. TWO THE TUEW C NO OUT THE OTHER PORT TIME BRAZING. 5. AFTER BRAM OPERATION OF REFRIGOIM T LIEBOTH OUTDOOR S TO BOADOOR NO wow LMT CA LILTED. ME FEU) BRAZED COPMECTIOPS MET BE CHIEQED FOR IEAICS. PTIESSURGI THROUGH THE SERVILE MLVE PORTS. THE IOOOR LI MT MCI FIELD REFIROERVIT LIMES WITH CRY !CROCE?* W 200 PSI USE SOAP BUBBLES OR OTHER LEM-oECIOrG METHODS TO SEE THAT ALL FIELD AB CS ARE LEAK FREE. REPAIR MY LENS APO RECIECI( BERME CHARGING MIDI TO COMPLETE CHARGE 6. MSULATE REFRIGERANT SUCTION UK N11Hi 3/4" 1I PRE-- fOiiE EuSi01E3R1C INSULATION TUBING: 'imafruX "R BATDr. OR ECM. 7. SOLDrOO VALVE REQUIRED rOPE PER 0110011 a SIZE 13 Tall MS A1: A60rl . WW1 UQLI10 LK SaFN� two( AS Clad( AS POSSIBLE To EXPMi6Ol1 was ( ). WIRING BEnmN Comic UNIT & SOUNDI VITLAE It LOCATE A PRESSURE Ti1P NEAR NE ECIUN. ZER EIRE OBI FOR SLIP AT MEASUREMENT IMO Tx11 AOJUS'1ENT_ 9. PROM.OE MLE E FLIER CINERARY • REFER T F DT ?RIMED WITH IBS (TIME P T T+t -J ��N CRIER MI L 1 t 1a SUCTOT UNE TRAM AT THE BASE OF THE 9X:101 ME RISER 6 TOT Wain. PER TRINE =DOER R 1949 NEWSLETTER MUNE 27. NO_4) DUAL L — REF GE AT ON P'PIN3 CAGRAM Sack pat 0-2-00 T AllicorreCIIRAL AmpoillECIORAL MAIMS XIFIEF DAMES PER SECTION 304 Iqq'] UMG CONDENSATE SH L BE DISCHARGED TO N APPROVED PLUMBING FIXTURE OR DISPOSAL AREA.�SHALL NOT DRAIN OVER PUBLIC WAY SERVICE DEW f APPROVE) r► nebe,,% •r_I1 r A - : - 411. �f1 r" 0- • ^ ,F♦!•=,1• 1 i FOR CONSTRUCTION -� 1 a J Raft • o � z � ag ft Ch in ilea - �e 4 1 ‘) E 3 c A c O c c - a .1- W u Q ES I z� W r M.. ta) Y � °0 f ce tin Nt are eI IWR ham= 5/C5/ CCJ PENI?I1G CITY APPROVAL M-o.i OWNS eft formic 2Sb' 4 7 c — VW" PINV 04 IPEAS jabri F •