Permit M2000-014 - ZAMA NETWORKS
City of Tukwila (206) 431-3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: Type: Category: M2000 -014 B -MECH NRES MECHANICAL PERMIT Address: 12101 TUKWILA INTERNATIONAL BL Location: Parcel #: 092304 -9309 Contractor License No: MCKIN* *372ND TENANT OWNER CONTACT CONTRACTOR ZAMA NETWORKS 12101 TUKWILA INT'L BL, TUKWILA WA 98168 SABEY DAVID A & SANDRA L 101 ELLIOTT AV W #330, SEATTLE WA 98119 DAVID HOWE 5005 3 AVE S,, SEATTLE WA 98134 MCKINSTRY COMPANY Phone: 206 762 -3311 5005 THIRD AVENUE SOUTH, PO BOX 24567, SEATTLE WA 98134 Status: ISSLIED Issued: 02/11/2000 Expires: 08/09/2000 Phone: Phone: 206 281 -8700 Phone: 206- •762.3311 **** kk* k**** k* k** kk************* k• k** k**' k• k**** k** •**kk*kk * *k* *•k*•k*k•kk* **k*k** Permit Description: 1st FLOOR TI MECHANICAL SYSTEMS FOR DATA CENTER 2nd FLOOR TI MECHANICAL SYSTEMS FOR OFFICE UMC Edition: 1997 Valuation: Total Permit Fee: 510,000.00 198.25 ****• k** k**k*• k**• k*• k*• k*** k**• k*• k*** kk******• k*• k* k*** k *•kk•k** *kk•k *•kk*k*•k*k*•kk•k• k* °DOD° eara044r rr Permit Center A3horized Signature Date I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. 1 am authorized to sign for and obtain this bui ing permit. 4'4?-Z.5:11:16xue 5lgnatur c, Print Name:erodttrie:L./.,e1. /' � Date: "2'••~ - /"2'4 Oe.1 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. • • CITY OF TUKWILA dress: 12101 TIIKWILA` INTERNATIONAL OL Suite: `enan t; : ZAMA NETWORKS • ypa :' I -MECH . Parcel I: 092304-9309 ****k`' k*l• A•k•k * *k•k•kA*kk* * *"k * * * * *•k *l k•#* * ** * * *•k *•k *kkk•k * ** "kit* * * ** * **,i ***A * *kk"kk•A* permit Conditions: :,JJ1umbing permits shall be obtained through the Seattle -King County Department of pub l.i c HOa.l t }t: l,umb i ng will be inspected by that 4igenc including a,11 'gas piping J296-4722). Electrical permi-,t`� : "ilia 1 1: be obtained through "'the;, Washington ;State Division,,-cf Labor an_Yd Ifldustries and,e11 electrical work will be inspected by that agency (2:48.663x) . t No changai.P .111 b0(146 tgade to the A:p1ans un lesg` rOppraved . by the Enginee« td ,'.the.. ui w4 1,a,. Rui ld,ing t)ivfs son. . ,Ali pe er1.ts,,x .inspact;:itvn reoords, and approved plans' sha,1 � be avai 1ab-1.e at the job site prior , to,, >the start: of "any, con stru0,0foni here,= dvcobri : "a t arse to;. be maintained at,d avai ebl Mitt..., ! . nal' ins+` ction�`` " � � ,�.. � � �r�p p ro "v a 1 )s granted:, : f • A11 rns$tt�r�ue inn to ;' don Sri oianfor nattce With ap rovod •p t a a d r' •gu;1.rer�o :ts.: of .. he Uniform dui 1 d I ng Code (1`.997 Ed t;, on1 .aa emended,,. Unri form Mc chan i ca 1 Code (1997`, - Ed,f.t i'on ) an : ,Washingtotn State Enuryy' Code. (- 199 %'E ii'tion) . Permit No: M2000 -014 Status: ISSUED Applied: 01/19/2000 Issued: 02/11/2000 ryL V ;i..i i ty of Permit: The i,aeuanc©:'of a permit or approval l o ^ epee i f i'Ca t ions, and camputa ions shell not be can od to;lbea por�mit =` for`, f'ur an approval of, any violation y - of,, tlrp prcmi s l ons of the building , code or of any, ordinance of,the Jurisdiation.. No permit presuming t atttltor;i ter to` violate or cancel ' ,the= prav i s t ons of' this haiii xbe .valid. ctgrer`a installation instrucx,iona required nn.site' lisp bu,l i°+ i ng inspectors review. CITY OF 7 '' 'KWI LA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 :::::zo.. —- . O ui Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. Project Name/Tenant: , Valu of Mechanical Equipment: Site Address : City State/Zip: `2 /o / /'o•c,T`• �( #G✓to S, tv- rN44 /%/ 7576 T x Parcel Number: D 92.3 c' 4' - ? -7L'� Property Owner: / 5a. .9e Co /II Signalura,"' , Phone: (- ) e/- ¢,,a Street Address: st,.-re 33 a /v 1 4 // ;o,? L ✓P /� wit State/Zip: 4' C'',. 9 Fax #: (e061 ✓ .z , ? gs/ Z °' Contractor: inck.n_f ty C01 Is) Phone: (106 ) X ? -J3 // Street Address: 7 44� £Cn /e `✓� City /.State/Zip: Fax #: ("ZoG) Yo' .. Z 6? y Contact Person: A an. vii l#74 A" je �jd "v�y State/Zip: Phone: (70 ) 7(z_. -.3 3/ Fax #: (Zd 6 ) 7 / 7 .z 1/ Street Address: �� MECHANICAL PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) Description of work to be done (please be specific): t~ Current copy of Washington State Department of Labor and Industries Valid Contractor's License, If not available at the time of application, a copy of this license will be required before the permit is Issued OR submit Form H-4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agents If the applicant Is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT / HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT, BUILDING'OW, OR AUTHORIZED AGENTt accep O Date a lication ~ Signalura,"' O Applicati take : ( Date: _ Is) .Z. &ate 0 Print namtt / v„ . e t/ .1. I Phone: (ue 1 ,)6j- iv , _ Fax N: ( ) Address: sev 00/.... e"` If City /State/Zip: / ., y Expiration of Plan Review • Applications for which no permit Is issued within 180 days following the data of application shall expire by limitation, The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114,4 of the Uniform Mechanical Code (current edition), No application shall be extended more than once, Date pplf t' accep O Date a lication ~ es: O Applicati take : ( • Is) •11/1/99 was pernadoc •r,N r • • • ,: ..r • Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal ✓ Submittal Regtiirr'rne►►ls Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) V Details and elevations (for roof mounted equipment) and proposed screening VHeat Loss Calculations or Washington State Energy Code Form #H -7 H,V,A,C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009), V Specifications must be provided to show that replacement equipment complies with the efficiency ratings nd other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of.existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. NOTE: Water heaters and vents are included in the Uniform Mechanical Code -- please include any water heaters or vents being installed or replaced. RESIDENTIAL: Two complete sets of attachments required with application submittal st►1)r ►1111Jl Rr ►lairrn►► r►1 New Single Family Residence Heat Toss calculations or Form H•6, Equipment specifications. Chan e-out or re . lacement of existin mechanical e - u! s ment Narrative of work to be done Includin: modification to duct work. Installation of Gas Fire . lace Narrative with specification of equipment and chimney type. It using existing chimney, provide n letter by a certified chimney sweep stating that the chimney Is In sato condition, NOTE: Water heaters and vents are Included In the Uniform Mechanical Code — please include any water , heaters or vents being Installed or replaced, ,;0 11/1/99 miscp►r►t:doc E"<u r� A • Al' r ■ 4 4 �• ;r, sue-' - K- r � �z:x �r '��` a "t��' 7r':.�'.�i�? ^4* . *A'** 4s4 ** *41AAAr$t4sir:4si hh- AAs4hhA **A *h*44* * * * *A A4A*4' 4** *****A *hi4 r r OFHTUKWILA. OA 01L4 1 at.tf48mi r 4A *;4.. *#*****%* 4**A A4* A*; i:. si4As4. i*Ait- 4: 4 **.k:A *.ihA* ***A *Ah**4 *A:4%*** 'RANfMit1' Number: 89000234 Amount: 198.25 07/11/00 12 :5 Payment Method: CHECK Notation: IIC$ UUD'rRY CO twits `fLt1 - 1. i s *. .... !.f'.t .. F — r /a MM M+ ♦i M.+ u -: .0 in ..r #i 4. a+ as N .w 'i. W. • F ... W w Aa O..a. w 4.... w:.s r W w .: 1. .i r. i, *. .s t w .W ... Y♦ r 1 — Yr si 1' drto 1 t Not M2000-014 typo: (3 14 C14 MECHANICAL 141 t( 1. 1''ERM 1 c P k r c P l No: 092304.9309 3 LL o- fdJrGa «µ 12101 rUKWI L j INTERNATIONAL OL Total rtsvtt t 198.25 Thit..Payment 198.25 Total ALL I'mmto ::. 1:10.25: Y)ulttnces .00 k*' A;* t4h'g* 1i,* A* A** s4* AhhAs 4* 4s1* AkA * #s1hA * * *'t*'i #'A *y4 * **°A,4A 4A # #kkk'AAkh #'4 -A cr.'uu },i Code D i cry t i,t t on Amount 000/345.9I30 PLAN . CHECK .• i4O1+ RC 000/322.100 MCCUftt1TCAL rIOP EE> • 154.00 44 If N! AS N •f ns aN H• q .. ✓. +. N •a .x :a tb .Y 1. M wit H w .r 1. IU U It n w .. .. t. as .• f. -* b. d. +. .s • INSPECTION NO. INSPECTION RECORD Retain a ropy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Proj Type or s . ectTon: Ad. : s Date called: Sp dal instructions: 8 y'7" `+ Jer Date wantjld: a,m. Requ r!tc % .. Phone: Approved per applicable codes. J Corrections required prior to approval. $47.04 REINSPECTION TE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd. Suite 100. Call to schedule reins . ection, INSPECTION RECORL) Retain a ropy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 WO- MO '1)1 Li. PERMIT NO. (206)431 -3670 Project: T • e of I spection: LA' .A. ( r -. .,i OA di, Address: dw �. D • called: , \RyJ + - V Special Instructions: D • tow e : co Approved per applicable codes. 'orrections required prior to approval. COMMENTS: d a* 4 ' 2 fro' / 4'11s,5 647.00 REINSPECTION FEE REQUIRED, Prior to Inspection, fee must b© paid at 6300 Southcenter Blvd„ Suite 100. Call to schedule reins ' ection. Receipt No: Date: INSPECTION: RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIV15 Nc 6300 Southcenter Blvd, #100, Tukwila, WAt 98188 PERMIT NO (206)431.3670 • C T 0 f • ectidn: Oa Date ca ed: Special instructions: Date w ; nt Oil de Requ rt . 4. Phone: .� Approved per applicable codes. Corrections required prior to approval, $47,00 REINSPECTION ESE REQUIRED. Prior to inspect on fee must be paid at 6300 Southcente Blvd. Suite 10R: Call to schedule reins action. Receipt No: Date: INSPECTION RECORD^ ---1 V Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter 131 0,41004 Tukwila; WA 98188 PERMIT NO. (206)431 -3670 Pr. e t: w C. Type of Inspection: Address: I Da e c • j 71; •' Special instructions: hasp q:r p (e0,, CCW e _. _ Da �•d:j , � .m. „ ILO yt ail ���'' WY Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: 5 *w%r (1,7 ,I1e w Allirr A( _.> . .' 4 r. r . ' . Lt. 41141Fr Date;,20,7 7.00 REINStECTION LEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd. Suite 100. Call to schedule reins ' action. Receipt No: Data: 1. • INSPECTIO NO, CITY OF TUKWIIA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 981131,1 INSPECTION RECORIOrMcoo _04 Retain a copy with permit PERMIT NO (206)431-3670 . • ii i k. ! . 40 . Type of inspe tion: Address: ' .% • '--- ,.. . A . A Date call... . C I III Spec a nstruct ons: Date & -. 1 . . Requ. ter: .... 4.fr..! Ai Ica I _. Ph. • 411. , ID Approved per applicable codes. Corrections required prior to approval, COMMENTS: _. .... ,ar 117 •... _ -,. "ff._ ' .410100-41 ., ..... ",. _1 •1 if .'' ' . 411..411 aid" . .,. , / . e .iiil Alle.dir 4111, 49.-ir _. . AI ..... ..................;....................—...,.......n..—....... ./. Alii. / - Inspector: Date: 0 WAR REINSPECTION FEE REQUIRED. Prior to inspection, fee nn( be paid at 6300 Southcenter Blvd, Suite 100. Call to schedule reins ection. Date: Receipt No: al**3.„00,64.44sra-tk-4, , , 1 INSPECTION RECOR Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO (206)431 -3670 • • ject: 4 WI e,,[ Ty' e • f Inspecion: r 2 (A rn S IC, Address: 0 i , (10 Date c�y: I OD Special Instructions: ill v _L._ Date wanted: ,m: aequ4a )1 Phone; (_ /► Approved per applicable codes. COMMENTS: Corrections required prior to approval. )Y Date: $47.00 REINSPECTION FEE REQUIRED, Prior to inspection, fee must be paid at 6300 Southccntor Blvd., Suite 100. Call to schedule reins.ection. Receipt No: Date: 44.41114,944e a.: 1 1 g A000- INSPECTION RECOR Retain a ropy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION . 6300 Southcenter Blvd, #100, Tukwila, WA 9818 PERMIT NO (206)431.3670 Pro) t' Typ • of Imp • • ctio : _" gy i,r /sr . . (1;;, Add= (J 1 Tu. v t iv I i Date i t O I � . •. Special instructions: )` WI Date wyrdj, of co ,, a.m. ` �� , w Phone n S Appred per applicable codes, J Corrections required prior to approval. EY COMMENTS: ir • TO // 4 _" gy i,r /sr . . (1;;, • //VS ", o ; A,, r / St410, 4 • L .,47- /41444 WSW" 0'6' s%r �� , w 0 • � # I Sr i ing&Ir ~+ • 0 C,, ' .S'?"' i t A ovz i s C.., " %r ' % 4-77 - J rillififf(11111111Lalit 0 547.00 REINSPECTION SEE REQUIRED. Prior to inspec on, fee must be paid at 6300 Southcenter Blvd, Suite 100. Call to schedule reins ' ection. Receipt No: Date: MIIIIMINIMIRINIMMOMINIMMINOMEMINOMINIP • INSPECTION NO CITY OF TUKWILA BUILDING DIVISION . 6300 Southcenter Blvd, #100, Tukwila, WA 98188 INSPECTION RECOR Retain a ropy with permit PERMIT NO. (206)431.3670 Prct: VS - Type of In ectio : • . ress• • — .. I 4 , i PA Date calle : 0 Special instructions: Date wanted: a. Reque rg: Approved per applicable codes. Corrections required prior to approval. $47,00 REINSPECTIO /FE REQUI ED, Prior to inspection, fee must be pald • at 6300 Southcenter Blvd., Suite 100. Call to schedule relnspection. Date: t. City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director August 16, 2001 Mr. David Howe 5005 3rd Ave. S. Seattle, WA 98134 RE: Permit Status M2000 -014 12101 Tukwila International Blvd Dear Mr. Howe: In reviewing our current permit files, it appears that your permit for installation of mechanical systems for data center and 2nd floor office for Zama Networks issued on February 11, 2000, has not received n final inspection as of the date of this letter by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the building official under the provision of this code shall expire by limitation and become null and void lithe building or work authorized by such permit is not commenced within 180 days from the date of'such permit. or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, if'n final inspection is not called for within ten (10) business days from the date (Willis letter, the Permit Center will close your tile and the work completed to date will be considered non - complying and not in conformance with the Uniform Building Code and /or Mechanical Code. Please contact the Permit Center at (206) 431-3670 if you wish to schedule a final inspection. Thank you for your cooperation in this matter, Sincerely, Ka tit pl.. a • r e9G' Kathryn A, Stetson Permit Technician X;; I rmit I iIu No, M2000.014 tf IDuunu tiriIiin, Building 0111001 6300 Southcenter Boulevard, Suite !#100 Tukwila, Washington 98188 • Phone: 306.431.3670 • Fax: 306.431.3665 BALTIMORE Alrtk.;OIL ONE Of THE Amsted INOUSTAIES SUBMTAL DATA FORI\I FILE COPY C U s T 0 M E R MCKINSTRY COMPANY P. 0. BOX 24587 SEATTLE, WA 98124.0567 DATE P.O. NO, B.A.C. NO. MODEL NO. 12/9/99 0000504201 MAD 0000504202MAD (2) FXV- L644 -LMQ PROJECT: ENGINEER: B.A.C. REP: ZAMA PROJECT - TUKWILA, WA MCKINSTRY COMPANY - SEATTLE, WA WASHINGTON AIR REPS, INC. - BELLEVUE, WA itri(V:CLOSID,CIRCUIT,,COOLING T01KER "ALL INFORMATION 18 PER UNIT" CERTIFIED CAPACITY: 600 USGPM OF 30% PROPYLENE GLYCOL FROM 96 F TO 82.4 F AT 68 F ENTERING WET BULB AND 11,26 MG SPRAY PRESSURE. FAN MOTOR(S): (1) 16 HP, 1800 RPM, 3 PHASE, 60 HERTZ, 460 VOLTS, INVERTER DUTY, TEAO ENCLOSURE. FAN DRIVES BASED ON 0" ESP, PUMP MOTOR(S): (1) 6 HP, 1800 RPM, 3 PHASE, 60 HERTZ, 230/460 VOLTS, TEFC ENCLOSURE. NOTE: Ywo speed fan motors and /or Energy Miser Fan Systems require a starter that Incorporates a 15 second time delay when switching from high to low speed. Invert., Duty Fan Motors, furnished In accordance whh NEMA Standard M0,1Part 31 are required for.ppEcatlon. using Venable Frequency Drives for fan motor 3 COPIES OF SUBMITTAL DATA FOR RECORD FEATURE FEATURE UNIT DIMENSIONS & SUPPORT DATA BAC- 17113A BAC- 17118A BAC•17163AX MECHANICAL SPECIFICATIONS LOW SOUND FAN SYSTEM ELEC. PAN HTR PKG., (1) 12 KW BAC- 16787A BAC•16770A ELEC. WATER LEVEL CONTROL PKG., BAC- 17247AX 110 VOLTS BAC -9201 B EXTENDED LUBE LINES INTERNAL. LADDER(S) BAC- 16560A W /BALTIBOND• SUPPORTS RECOMMENDED CONDUIT INSTALLATION BAC- 18626A EXTRA SOLENOID VALVE PVC SHEATH TYPE 318 PROBES (1) RIGHT HAND & (1) LEFT HAND ARRANGEMENT THANK YOU FOR YOUR ORDER ACCEPTED AT THE B.A.C. MADERA PLANT ON: 11/17/99. AN APPROVED SUBMITTAL IS NOT REQUIRED. YOUR ORDER IS SCHEDULED TO SHIP FROM OUR FACTORY APPROXIMATELY 1/14/00. PLEASE BE PREPARED FOR THE ARRIVAL OF THIS EQUIPMENT, AS OUR FACILITIES CANNOT ACCOMMODATE THE STORAGE OF COMPLETED UNITS. THE SUBJECT FXV4.644•LMQ WHEN INSTALLED AND SUPPORTED AS RECOMMENDED, HAS ANCHORAGE TO RESIST WIND LOADS UP TO 30 PSF AND SEISMIC FORCES UP TO SEISMIC ZONE 4 AS DEFINED IN SECTION 2313 OF THE 1991 UN /FORM BUILDING CODE (UBC) FOR FACILITIES WITH IMPORTANCE FACTOR OF 1.0. ANCHOR BOLTS ARE FURNISHED BY OTHERS. RECEIV D P.O, BOX 7322, BALTIMORE, MARYLAND 21227 / TELE: (410) 799.6200 / FAX: 410499.8416 P.O. BOX 980, MADERA, CALIFORNIA 93839 / TELE: (559) 873.9231 / FAX: 559.873.5095 M ZOOO-OIij JAN 19 2000 512099 PERMIT CENTER S Terms and Conditions of Sale Pricing: Prices will remain firm, provided the order Is released for fabrication within six (8) months after receipt of the order by the Seller and shipped within Setter's standard published factory feed times. For each additional month or portion thereof, one percent (1 %) of the price per month will be added for a parted to exceed six (6) months, after which the price in effect at time of shipment will apply. If an order is released but shipment 1s not accepted when produced, prlo will be subject to the same adjustments. Payments: If the Buyer shall fail to make any payments in accordance with the terms and conditions of sale, the Seller, in addition to it's other rights and remedies, but not In limitation thereof, may at its option defer shipments or deliveries hereunder, or under any other contract with the Buyer, except under receli of satisfactory security or cash from the Buyer before shipment, Taxes: Prices do not include any sales or use tax, either federal, state, or focal payable on the transaction under any applicable statute or regulation. All sucl taxes must be paid by the Buyer. Warranties: Seller warrants that the equipment sold under this contract shall be free from defects in material and workmanship for a period of twelve (12) mon from the date of equipment startup or eighteen (18) months from the date of shipment, whichever occurs first, The following mechanical equipment component only are warranted against defects in materials and workmanship for a period of five (8) years from date of shipment: fans, fan shaft, bearings, sheaves, gearboxes, drive shafts, couplings, mechanical equipment support and fan motors, Written notice of any defect shall be given to Seiler Immediately upon discovery by Purchaser, and shall fully describe the claimed defect. Defective parts shal repaid or replaced F.O.B. point of shipment, provided that inspection by Seller verifies the claimed defect(s). This warranty does not cover the costs of removing, shipping or reinstalling the equipment. Repairs made without the prior written approval of seller shall void aft warrantles covering mater and workmanship. Any descriptions of the produd(s) In the contract are for the sole purpose of identification and do not constitute a warranty, In the Interest product improvement, Seller reserves the right to change specifications and product design without Incurring any liability therefor. The foregoing express warranties are the only warranties of Seller applicable to the product(s) sold under this contract. All other warranties, whether verbal or written, and all warranties implied by law, including any warranties of merchantability or fitness for a particular purpose, are hereby excluded, Failure on the part c Purchaser or of other parties to properly maintain the product(s) sold under thls contract, or the operation of such product(s), by Purchaser andlor other parties under conditions more severe than those for which such product(s) were designed, shall void all warrentles covering materials and workmanship, Seller's warranties do not apply to defects In products) for which payment In full has not been received by Seller, and said warmth do not cover normal wear and tear or the erosion, corrosion and/or Moderation of the product(s) from unusual causes. Seller shall In no event be liable for consequential, Incidental or special damages arising out of a breach of any of Its warranties or obligations hereunder. No warranties by Seller shall apply to accessories manufactured by others, inasmuch as they are warranted separately by their respective manufacturers, except as stated above. Purchaser assumes liability for and shall bear the costs of compliance with all laws, regulations, codes standards or ordinances applicable to the locatl operation and maintenance of the product(s) sold under this contract, Including those requirements pertaining to the distances between such produd(s) and sir conditioning system duct intakes, No representative or agent of Seller is authorized to enlarge upon the express warranties of Seller. Shipping Oates: Shipping dates arc estimated only. No agreement will be made to deliver In a specified time unless in writing by an official of the Seller, eel shall under no circumstances be responsible for failure to fill any order or orders when duo to: fires, floods, war, riots, strikes, freight embargoes or transportat delays, shortage of labor, inability to secure fuel, material, supplies or power at current prices, or on account of shortages thereof; ads of Ood or of the public enemy; any existing or future laws or acts of the Federal or of any State Government (Including specifically, but not exclusively, any orders, rules or regulations Issued by any official or agency of any such government) affecting the conduct of Sellers business with which Seiler In Its judgment and discretion deems It advisable to comply as a legal or patriotlo duty, or to any case beyond the Bolles's reasonable control, Allocation of Risk: The responsibility of the Seller ceases upon delivery of products to the carrier, The Buyer assumes all risks of loss, damage or shortage transit, and any claims based thereon must be filed by the Buyer with the sales. Returns: Products may not be returned except by permission of authorized factory officials of the Seller and when so returned will be subject to a handling charge and transportation costs payable by Buyer. Government Contracts; If Buyer's purchase order is for products to be used In the performance of a U.S. Government contract, those clauses of applicable procurement regulations mandatorily required by federal law to be included in U.S. Government subcontracts shalt be Incorporated herein by reference. Agreement of Sale: All orders are subject to review and acceptance by the Seller, including all terms and conditions related thereto. Any of the tern's and conditions of Buyers order, or amendments or additions thereto, which are inconsistent with the terms and conditions herein shall not be binding on the Seller shall not be considered applicable to the sale and shipment of the products, No waiver, alteration, or modification of the provisions hereof shell be binding on m Seller unless made In writing and agreed to by a duly authorized official of the Seller. Waiver by either party of any default by the other hereunder shall not be deemed a waiver by such party of any default by the other which may thereafter occur, Orders accepted by the Seller are subject to anceilation only upon Wr consent of the Seller and after payment by buyer of reasonable costs and expenses for the effort expended thereon. The agreement of sake shall be govemec and construed in accordance with the laws of the State of Maryland. 4 ti. RECEIVED CITY OF TUKWILA JAN 1 9 2000 PERMIT CENTER (Revised 2/23 i!sp 'i 0077 CERTIFIED December 9, 1999 Baltimore Aircoil Company Series FXV Closed Circuit Cooling Tower Mechanical Specifications G -235 (Z700 metric) Not -Dip Galvanized Steel Construction Project Name: Customer Name: Purchase Order No.: Engineer Name: Model Number: B.A.C. Serial No.: Unit Type: Thermal Performance: Quality Assurance: Cold Water Basin: Strainer: Water Level Control: Bieed .Off: Pump: Casing: ZAMA Project - Tukwila, WA McKinstry Company - Seattle, WA McKinstry Company - Seattle, WA FXV- L844 -LMQ 0000504201/02MAD Factory assembled, induced draft, closed circuit cooling tower with vertical air discharge. All structural steel components are constructed from G -235 (Z700 metric) hot -dip galvanized steel. The edges are given a protective coat of zinc -rich compound. Thermal performance Is certified by the Cooling Tower Institute In accordance with CTI Certification Standard STD -201. Each unit is manufactured under closely - controlled conditions using standardized parts to ensure each unit is built precisely to the same high - quality design and construction standards. The design, manufacture, and business processes are 18O 9001 certified, Constructed of heavy gauge G -235 (Z700 metric) hot -dip galvanized steel. Basin Includes a depressed section with drain /clean -out connection. Large area lift out, G-235 (2700 metric) hot -dip galvanized steel strainer screen has perforated openings sized smaller than the water distribution nozzle orifices. Strainer includes anti- vortexing baffle to prevent air entrainment. Probe -type package including solid -state relay, electrode fitting, electrode, and solenoid valve in the make -up water connection. Waste water bleed line with odJustable valve provided, Close - coupled, bronze - fitted, centrifugal pump(s) with mechanical seal is fitted with a drain plug to allow complete drainage. The pump motors) is totally enclosed, fan - cooled (TEFC), suitable for outdoor operation. Casing is constructed entirely from heavy gauge, G -235 (Z700 metric) hot -dip galvanized steel panels. Page 1 CITY OF TUKWILA JAN 19 2000 PERMIT CENTER Access: Air Inlet Louvers: Water Distribution System: Wet Deck & Eliminators: Coll: BALTIDRIVE® PowerTrain: Fan Shaft and Bearings: TEAO Fan Motor(s): Fan and Fan Cylinder: Fan Guard: A hinged 27" X 43" (686 mm X 1092 mm) access door is provided on the end wall of the unit for access to the eliminators, coil, and fan plenum section. Access door is constructed of heavy gauge, G -235 (Z700 metric) hot -dip galvanized steel. Air inlet louvers are wave - formed, fiberglass- reinforced polyester (FRP), spaced to minimize air resistance and prevent water splash-out, G -235 (Z700) hot -dip galvanized steel spray header and Schedule 40 PVC spray branches. Removable spray branches and 360° spray pattern plastic nozzles are held in place with snap -in rubber grommets. The BACross® Wet Deck Surface and integral drift eliminators are formed from polyvinyl chloride (PVC). They are impervious to rot, decay, and fungus or biological attack and have a flame spread rating of 5 per ASTM Standard E84 -77a. A separate set of eliminators is removable in easily handled sections for quick access to the coil. Ali eliminators are designed to effectively strip entrained moisture from the leaving airstream with a minimum of air resistance. Continuous 1.05" (27 mm) O.D. all prime surface steel encased In steel framework with entire assembly hot -dip galvanized after fabrication. Tubes sloped for liquid drainage. Coil has a design pressure of 280 pslg (1900 kPa) and is tested to 350 psig (2400 kPa) air pressure under water, Fan(s) are driven by a one -piece multi- groove, neoprene /polyester belt designed specifically for evaporative cooling equipment service. Fan and motor sheaves are non - corrosive cast aluminum. The BALTIDRIVE® PowerTrain, Including fan motors, Is warranted against defects In materials and workmanship for five (6) years from date of shipment, Fan(s) and steel fan shaft(s) are supported by heavy -duty, self- aligning, grease - packed, retubricatable ball bearings with special seals for protection against dust and moisture. All bearings are designed for minimum L10 Ole of 40,000 hours (280,000 hours average life). Fan motor(s) is totally enclosed, air -over (TEAO), one speed, one winding, reversible squirrel cage, ball bearing type, designed specifically for evaporative heat rejection service. Motor Is furnished with special moisture protection on windings, shafts and bearings. Motor is designed per NEMA MG1 -Part 31 for Inverter Duty service. Fan(s) are fixed pitch, heavy duty, cast aluminum, axial flow. The heavy gauge, G-235 (Z700) hot -dip galvanized fan cylinder(s) are designed for streamlined air entry and minimum tip clearances for maximum fan efficiency. A heavy gauge, hot -dip galvanized steel wire fan guard Is provided over each fan cylinder. Page 2 RECEIVED CITY OF TUKWN r JAN 1 9 ?000 PERMIT CEt4TEk Anchorage: When installed at grade and supported as recommended, the unit has anchorage to resist wind loads up to 30 psf (100 mph straight line wind) (148.6 kg/m2 (44.7 m/s straight line wind)) and seismic forces up to seismic zone 4 (.6g lateral acceleration), importance factor 1.0, per the 1991 Uniform Building Code. Basin Freeze Protection: An electric immersion heater package, sized to maintain +40 °F ( +4 °C) basin water at 0 °F (•18 °C) ambient with a 10 mph (16 km/h) wind speed, is provided. The package includes a minimum number of high-watt-density electric immersion heater element(s), thermostat(s), and low water cutout switch(es) or probe(s). Disconnect switch, contactor, and wiring are not included. Internal Access: A movable aluminum ladder and fixed support is provided in the plenum to access the fan drive system. Extended Lubrication Lines: Bearing lubrication lines are extended to grease fittings loceted'on the face of the unit. ,TM opElVED•,} JAN 1 9 2000 PERMIT CENTER Page 3 t • . ELAN VIEW 1/2" FPT VENT 5' -0" FAN DIA (SEE NOTE 5) SIZE (SEE TABLE AND NOTE 3) ACCESS DOOR THIS END ONLY 3' OVERFLOW 2" DRAIN -I lisi.1* -0" �-j •- 2' -2 3/9" LUID FLUID IN MINIMMIN 1/4 "�II 1/8"-.1 ,.._..._... 11' -10" IFIFIWIMMMINNIF ROWS END VATION o.wu'.I- NUMBER ,,9 m r u.0 WEIGHT ur 6Iu1 1 uvu WEIGHT SECTION UPPER wPIN" IIUN SIZE r FXV- 641 10,890 18,560 6730 4" 24 FXV-. 642 11,930 20,050 7770 4" Rai 4 23,050 9860 a • 4" 51 3/4 FXV- I.64 4LM Q 14,040 1. ALL DIMENSIONS ARE IN FEET AND INCHES. WEIGHTS ARE IN POUNDS. 2. DIMENSIONS SHOWING LOCATION OF COIL CONNECTIONS ARE APPROXIMATE AND SHOULD NOT BE USED FOR PREFABRICATION OF CONNECTING PIPING. 3. COIL CONNECTIONS ARE IPS BEVELLED FOR WELDING. 4. CONNECTIONS 3" & SMALLER ARE MPT, 5. THE AREA ABOVE THE DISCHARGE OF THE FAN MUST BE UNOBSTRUCTED. 6. FOR WEIGHT LOADING AND SUPPORT REQUIREMENTS REFER TO THE SUGGESTED STEEL SUPPORT DRAWING. •N 1'- 6 1 /4" 12` -1 1 /4" ---- -. ,SIDE ELrEVTLON 1" MAKE UP B.A.C. DER NO: W0 564 2 1 -IIkD DATE:. BALTIMORE AIRCOIL COMPANY SERIES 1500 FLUID COOLER 1� UNIT I� A*IO NUU&.R: BAC- 17113A ti MODEL NUMBER SHIPPING WEIGHT OPERATING WEIGHT HEAVIEST UPPERN CONNECTION SIZE F 10,890 18,560 6730 4" 24" FXV- 642 11,930 20,050 7770, SLT1 r,,MIN -T.11111 • T• . 1.11111111111M1111111111111111111MIEW Oda mr+.wi.s.d.q .........r..-- w.q .i..........-.w "n...�a.r.+ 4, FXV-L644 14,040 23,050 9880 MMI�,jI, 1, ALL DIMENSIONS ARE IN FEET AND INCHES. WEIGHTS ARE IN POUNDS, 2. DIMENSIONS SHOWING LOCATION OF COIL CONNECTIONS ARE APPROXIMATE AND SHOULD NOT BE USED FOR PREFABRICATION OF CONNECTING PIPING. 3, COIL CONNECTIONS ARE IPS BEVELLED FOR WELDING. 4. CONNECTIONS 3" & SMALLER ARE MPT. 5. THE AREA ABOVE THE DISCHARGE OF THE FAN MUST BE UNOBSTRUCTED, 6. FOR WEIGHT LOADING AND SUPPORT REQUIREMENTS REFER TO THE SUGGESTED STEEL SUPPORT DRAWING. 1" MAKE UP - � �--- -- 12' -1 1/4" SIDE ELEVATION .N -8 1/4" PLAN VIEW 1/2" FPT VENT 5' -6" FAN DIA (SEE NOTE 5).. ° N Gib "4 CONNECTION SIZE (SEE TABLE AND NOTE 3) ACCESS DOOR‘. THIS END ONLY 1L 2'.-2 1/4" 1. -2' -7 1/8" 111-10" -- -- ----� END ELEVATION 3" OVERFLOW 2" DRAIN H UNIT ORDER TE NO: �.0. (..w2 J QA: BALTIMORE AIRCOIL COMPANY SERIES 1500 FLUID COOLER DRAWING NUMBER: • BAC-17118A 19911e9ellimo►t Wed . M If RuavM, r3AC-- 17153AX MODEL NUMBER SHIPPING WEIGHT OPER, WEIGHT WEIGHT LOADING (LOS.) P1 P2 P3 ` P4 f P5 P6 P7 P8 FXV -1044 14,040 1 23,050 2798 1248 1248 : 2798 8878 801 ; 601 1 8878 , NOTES: 1. SUPPORTING STEELWORK AND ANCHOR BOLTS TO BE DESIGNED AND FURNISHED 13Y OTHERS. 2. ALL SUPPORTING STEEL MUST BE LEVEL AT TOP. 3, BEAMS SHOULD BE SELECTED IN ACCORDANCE WITH ACCEPTED STRUCTURAL PRACTICE, MAXIMUM DEFLECTION OF BEAM UNDER UNIT TO OC I /360 OF SPAN, NOT TO EXCEED 1/2 INCH, 4. ALTERNATELY THE UNIT MAY DF. SUPPORTED ON COLUMNS AT THE FOUR CORNERS OF THE UNIT. CONSULT YOUR BAC REPRESENTATIVE FOR DETAILS. 5. IF VIBRATION ISOLATION RAILS ARE USED BETWEEN UNIT AND SUPPORTING STEEL, QE CERTAIN TO ALLOW FOR THE LENGTH OF THE VIBRATION RAII.S WHEN DETERMINING LENGTH OF SUPPORTING STEEL. VIBRATION RAIL LENGTH AND MOUNTING HOLE LQCAI Ms MAY DIFFER FROM THOSE OF THE UNIT, REFER TO VIBRATION ISOLATOR DRAWINGS FOR THIS DMA. 6. DO NOT USE THIS DRAWING TO SIZE POINT VIBRATION ISOLATORS. SEE YOUR BAC REPRESENTATIVE FOR DETAILS. 7, SEISMIC & WIND LOADS ARE ADDITIVE 10 OPERATING LOADS. 7/8" DIA. MOUNTING HOLES 3/4" ASTM 325 ANCHOR BOLTS (4 REQUIRED) UNIT OUTLINE 10" OEM 011/111 •111%1MM MOM 11.1MI P4 FACED Pee P3 P7 • P2 P6 I 1/8" - 'PI FACE C Pd' It - ---1. 7 3 / 1 4" UNIT OVERALL 1i'-•10"--- �- ---�-� FLAN view 1 1 END ELEVATION CO 110" - 1 1/8" ORDER NO: OM 5014106 I /O. j DATE: BALTIMORE AIRCOtt.s COMPANY SERIES 1 500, FLUID COOLER STANDARD STEEL. SUPPORT aRAwiNC Nu�1eeR: BAC- --1715,AX SEIfilILOAM ZONE 4 UOC 1997 PI 1 P2 P3 P4 PS Pe P7 Pe ACE 0 RT 113700 - 1I37e0 * 3 +0 •.1 - BO JILL. i rdo NORM 9050 - 9050 9050 11 -33'0 9050 .__ - - t1�2 ! 0 90 0 Tar KRT c H•' . F1 - - 9050 - - 9050 P1 111 P3 Niximai P6 P7 Pe rACE 0 . ,:T k2 so - .. *21 'O -le*i r- - —::..—• - r • •. . 'jr 133.1. --z— X34- .1420. - .:_. ---- 'ACE or c ii. i , - - 4 - - NOTES: 1. SUPPORTING STEELWORK AND ANCHOR BOLTS TO BE DESIGNED AND FURNISHED 13Y OTHERS. 2. ALL SUPPORTING STEEL MUST BE LEVEL AT TOP. 3, BEAMS SHOULD BE SELECTED IN ACCORDANCE WITH ACCEPTED STRUCTURAL PRACTICE, MAXIMUM DEFLECTION OF BEAM UNDER UNIT TO OC I /360 OF SPAN, NOT TO EXCEED 1/2 INCH, 4. ALTERNATELY THE UNIT MAY DF. SUPPORTED ON COLUMNS AT THE FOUR CORNERS OF THE UNIT. CONSULT YOUR BAC REPRESENTATIVE FOR DETAILS. 5. IF VIBRATION ISOLATION RAILS ARE USED BETWEEN UNIT AND SUPPORTING STEEL, QE CERTAIN TO ALLOW FOR THE LENGTH OF THE VIBRATION RAII.S WHEN DETERMINING LENGTH OF SUPPORTING STEEL. VIBRATION RAIL LENGTH AND MOUNTING HOLE LQCAI Ms MAY DIFFER FROM THOSE OF THE UNIT, REFER TO VIBRATION ISOLATOR DRAWINGS FOR THIS DMA. 6. DO NOT USE THIS DRAWING TO SIZE POINT VIBRATION ISOLATORS. SEE YOUR BAC REPRESENTATIVE FOR DETAILS. 7, SEISMIC & WIND LOADS ARE ADDITIVE 10 OPERATING LOADS. 7/8" DIA. MOUNTING HOLES 3/4" ASTM 325 ANCHOR BOLTS (4 REQUIRED) UNIT OUTLINE 10" OEM 011/111 •111%1MM MOM 11.1MI P4 FACED Pee P3 P7 • P2 P6 I 1/8" - 'PI FACE C Pd' It - ---1. 7 3 / 1 4" UNIT OVERALL 1i'-•10"--- �- ---�-� FLAN view 1 1 END ELEVATION CO 110" - 1 1/8" ORDER NO: OM 5014106 I /O. j DATE: BALTIMORE AIRCOtt.s COMPANY SERIES 1 500, FLUID COOLER STANDARD STEEL. SUPPORT aRAwiNC Nu�1eeR: BAC- --1715,AX ELM THERMOSTAT 1/2 FPT THERMO. PROBE 11.ii EVVATIOI9 AIR IN NM -1014 4•1111•10110■11•111■11•11111•••••••■11111111110, uMli"' iO /Cr /H NOTES: 1, OMIT THE 1" FPT CUTOUT LOCATION WHEN AN ELECTRIC WATER LEVEL CONTROL PACKAGE IS USED. THE LOW WATER CUTOUT MALL BE FURNISHED AS PART OF THE ELECTRIC WATER LEVEL CONTROL PACKAGE. 2. HEATER: VOLTS, . PHASE, HZ, n' AMBIENT TEMPERATURE. 1" FPT LOW WATCR CUTOU r PROBE (SEC NOTE 1) k t h 2" FPT 1•ICAII:R 23 3/4 28 1/2 -- 30 7/8 RH UNIT i3. A.C. ORDER NO: /1,005547.,01107, DATE: / / BALTIMORE AIRCOIL COMPANY SERIES 1500 COIL PRODUCT HEATER LOCATION DRAWING NUMNER: BAC- 167.67A 1" FPT LOW WATER CUTOUT PROBE (SEE NOTE 1) N 2" FPT HEATER 23 3/4 28 1/2 30 7/8 S AIR IN PL._ THERMOSTAT B.A.C. ORDER NO: 4000502,01,0s-Ava9 DATE: / / 1/2" FPT THERMO. PROBE ELEVA'I, BALTIMORE AIRCOIL COMPANY 1. OMI THE 1" FPT CUTOUT LOCATION WHEN AN ELECTRIC WATER LEVEL CONTROL PACKAGE IS USED THE LOW WATER CUTOUT WILL BE FURNISHED AS PART OF THE ELECTRIC WATER LEVEL CONTROL PACKAGE. 2, HEISTER: VOLTS, ate HZ, _le_ AMBIENT TEMPERATURE. a Z LH UNIT SERIES 1500 COIL PRODUCT HEATER LOCATION DRAWING NUMBER: BAC- 16770A A La i V 1 1 %-1' / r1 /♦ ImOBMUmor. Meal M R' ! Roowm&. I ONE CELL..M UNIT_ ..�..�.- ...�� ..mom„ QJJ ;..,C LL LM UNIT /MOWN mob. - - New _� :.:. •• ■•••■•■•••wm.j rte. L 1, .^� TWO CELL, UNIT SUMS 15U( ELECTRIC WATER LEVEL CUN IIWL DON SIZE 81 2 x a VALVE QTY. 1 VA1,.4ZE, ONE CE�I, t 2' TW_O u 1 2" A 1'91 88" D 2'11 2'' 8 1 T K '9 ,....... I .. I/2'. J ",...,.�..I' 9 1 4' 2' 11 2" ........, v ..... 2' 3 I/8 ".2' 7 I /2" ,...,.�, 12 X 12 ....... I ,..,........� 1' ....._ 1' I ri 1_�►'�/1�1111 A ..1.. ∎110.x____ ..,� �IIt�,�1�q►.� - tee■ =.1.∎t . • eiliiasurr ELECTRIC WATER LEVEL CONTROL ELECTRIC WATER LEVEL CONTROL ELECTRODE PROOlS -- Qjg CELL; ELEVA TION rll u' ll T SIIOV.W, Ul UNIT CONNECTIONS ARE ON OPPOSITE END or UNIT. VIcWy A•-A CONDUIT CONNECTION PLATE LOCATION TWAT, SOLEI10I0 VALVE LOCATION • • •••■•■ • r X�7111 os rei mr I1" V 2I-0 Int A CONDUIT CONNECTION PLATE ELECTRIC WATER LEVFt. CONTROL PACKAGE CONDUIT CONNECTION PLATE It SOIANOID VAI.VF, LOCATION DIAGRAM 13.A,C. ORDER NO: DATE: 0666o2i2oilo2io4049-4 BALTIMORE AIRCOI.1, COMPANY SERIES 1500 COIL PRODUCT EWI- C PACKAGE DRAWING NUA19ER: I3AC..- 172417AX CORM 1111111 comet woe rot toot N( Nc ALT TMt kW( - - - - L 3' - - - 3' Mgr iQ°' S n/ ?" { Iftwt 1 110 MOW EMI -- J .1 .i - - - - -_ -1 ;)f ----- RtCOWI(NOIID WNINIO or 0Pi1ow NpTCR moo( MISIIIIMUlial OM IIONUC.01KI ole 1 o - -o No- 11- -Q t �P., NI - -Q II-- - - - .... Fc i - '+ 1 1) -4- 4- -- 4- b -c 1a 4.. y, 1 -fi-- "�--- -• —,-. { { {l g n 1 seasot ORDER NO: IMO SIO yrO/ higi DATE: ..- woe iI vs( Oi/ ---- , test V owl ON --- 1011 IIKL RIMY tar IWLII anon MVO BAC -9201 DX N0TES: 1. M11MI0 MO C0MNONtNIS INWA1tO NY CASINO INKS Mt 10 K SUPPLIED BY rose 01H(R tH* '1AC'. Alt WIRN10 INJSt COMPLY *ITN APPLKMlt CONS MO ORONIANCtS, 2, WOW/ C0N01AT AND CONNECTIONS W (N TN C CL(CTROOC I(Ao MO INC CONTROL 101, NN KtU1CN INC CONTROL 101 AND ACC(SSORKS MC TO K DOUG TIOM, W A004100 ?NC CON 1 K 01 IS 10 MOUN?(O SO toot tot A• ORANI IIOIC NS Al THC 1OT10M Oi THC 101, S. INC LI0U10 t1010 CONDUIT IS 10 K PROMO 1111H A C0N0CNSAMC DANN MO IS 10 K R0W(0 SUCH THAT INC ORM K At iHt LOW PORT 01 11C C0N0UIT RUN, 4, tot WATCR ltv(L CONTROL 100110 I{ MARCO NI THC PARS( N00? 10 THAT 1N( SOL(NOIO MAKC -UP WV( WILL CLOS( N iN(RC If A LOSS Oi POMtI 10 INC CONTROL 10M0. 041N to( WATCR L(KL RiMS 10 SIC (L(CTROOC 011 1(11iaNK •H' ANO MMNTAN S COSTAL'? /011 Al LOUT 1 KCNOS, INC CONTROL 0C- (N(ROIZU 1H( VALK, INC VALK INC ILCCa1R00t OWI T(IMMN LR INC N*0 CRMA iSSLATt 1(i(RL� ,0N At LEAH • SECONDS, 114C CONTROL iN(N (N(RGIi(1 INC YAM, S. tot NORMALLY CLOSED IOLCMOIO VAX I441 A KOW CL0WNI0 ,(ATUR( WWII WORKS WIX(1 WATCR IWAIKN MO K D(SI11(0 10 COMM AT MAKE -UP WARR UP( INKSSURC$ Or ID 10 110 PSIG, 10 TURIIKR wont INC P0l(NlIl /OR NAM NAMMCA, MAKC -VP WAI(R UNC PP (SINK$ Ai TIK *KKR (NO Or INC RANG( SHOULD K AY0100O3 440 MAN( -UP PIPING SHOULD 1C MKLL i UPP0RT(0. 1, WTCRLOCK w1KR1►0N *CATERS WITH CPRAY WATER CMCULATINO PUMP 10 0C- ENERGY[ IKATCR1 wH(N SPRAY PUMP IS RUNNING. T, CONTROL 1N(1110STAT if TO K AT 107, 00 N01 1(T 1H(RM0f1A1 LOWER MAN Oar, 1. CONTACTOR, /U_i[C PAOI(C110N TWO POWER S�UPPPP1LYY {No1100 MC WUUii COMMPLY 10 iA0PPLICASIL COOLS Nq0 ORONWICC1 1YM10Lf = I QUICK SLIDC CONNECTION 1ERIMNAl1 NC, C, 140 I CONTROL RELAY TCN014041 BALTIMORE AIRCQII, COMPANY ELECTRIC WATER LEVEL CONTROL DUAL SOLENOID VALVES WiTH LOW LEVEL HEATER CUTOUT k LOW LEVEL ALARM 04•0001 M1ANiA: BAC -9201 BX a':5'+'hw.v.. rim. Y... r. v;• y. »w.r,!.�.•..sr.o.- .....��...+.n .... .,. ACCESS • DOOR tom. 1. INTERNAL LADDER CAN BE RE- POSITIONED TO SEVERAL LOCATIONS ALONG THE LENGTH OF THE UNIT, V RH UNIT AIR A� IN IN FACTORY INSTALLED CHANNEL CZ ti N SEE_ NOTE 1 S OOR .V LH UNIT FACTORY INSTALLED ANGLE BASE BALTIMORE AIRCOIL COMPANY SERIES 1500 INTERNAL LADDER " •I• MOTOR —/ LOCATION PLAN VIEW RIGID CONDUIT OUTSIDE TOWER TURNED GOWN TO JUNCTION DOX OR SAFETY SWITCH DISCONNECT /SAFETY SWITCH --i IN WEATHER PROOF' ENCLOSURE MUST BE RATED FOR PROPER VOLTAGE AND HORSEPOWER OF FAN MOTOR HOLE IN CASING PANEL —r SHOULD DE LARGE ENOUGH TO ACCOMMODATE CONDUIT. SEAL HOLE MATH WATER PROOF SEALANT 6 SEGTIUN A—A ADJUSTABLE MOTOR BASE MOTOR LOCATION B.A.C. ORDER NO: 56 02 .• 1.= All CONDUIT BOX FLEXIBLE CONDUIT (ALLOW SUFFICIENT SLACK FOR BELT TENSION) 201121-11:11.- 111110 1. 1. ALL CONDUIT IsELEUILIMILBOLANILELTSMQ DOWNWARD TO ALLOW CONDENSATION TO DRAIN AWAY FROM MOTOR CONDUIT BOX. THEREFORE, DO NOT RUN THE CONDUIT THROUGH THE FAN DECK. 2. ALL WIRING MUST CONFORM TO LOCAL, AND NATIONAL EI.ECTRICAI. CODES, 3, RIGID CONDUIT OUTSIDE CASING PANEL MUST TURN DOWN TO JUNCTION BOX. BALTIMORE nir�CoIra � SERIES , Soo RECOMMENDED CONDUIT INSTALLATION COMPANY • .,.• •:r►... • DRAWING NUMBER: l3AC-- 16526A MN& Prepared For: Contractor: McKinstry Company Sold To: McKinstry Company P.O. Box 24567 5005 Third Ave S. (98134) Seattle, WA 98124 Submittal Date: December 14, 1999 Job Name: Zama Networks The Trane Company A Division of American Standard Inc. U The Trane Company is pleased to provide the enclosed submittal for your review. Products Included In this Submittal Package: Qty Description 1 Outdoor Central Station Air Handler Units Note: 1. We will provide a separate UL approved electric heating coil with 6 stages of control. The electric heater will require field mounting In a blank section provided, 2. A standard 2" filter rack will be provided In the unit that will require field modification to 4 ". Filter sizes and quantity will be the same as for the 2" rack, Seattle - Art Smith 2021 152nd Avenue NE REDMOND, WA 98082 Phone: 425-643-4310 Fax: 425643 -4314 0 0 ac 0 • n ormat •n • • os • equ pmon we propose 0 fum/sh for (his pmJoct, and Is Rubmlttod for your approval MZOcO»OI'I C :IWINDO WSITEMPIZAMAN VU.O00 RECEIVF.0 CITY OF TUKWII r. JAN 19 2000 PERMIT CaNTEFk Trani Submittal Page 1 of 12 Table of Contents Zama Networks December 14, 1999 Outdoor Central Station Air Handler Units (Item Al) Tag Data 3 Product Data 3 Performance Data 4 Mechanical Specifications 5 Unit Dimensions 7 Accessory 8 JAN 19 2000 PERMIT CENTEk FLD = Furnished by Trane / installed by Others Trans Submittal Page 2 of 12 Zama Networks Tao Data - Outdoor Central Sta ; Air Handier Units December 14, 1999 Item Tag(s) Qty Description Al , TSCX -1 _ 1 Outdoor Climate Changer Air Handler ( T Product Data Item: Al Qty: 1 Tag(s): TSCX -1 Unit Level T - Series Climate Changer Unit Size 12 UL Listed Unit Factory Painted Unit Standard Color Controls Package Mixing (Pos #1) Mixing Module Mixing Box With Filter Frame Insulation 2 "(51mm) Solid Dble Wall Back Damper - Parallel Blades Outside Air Back Inlet Hood Back Door Right Hand Access (Pos 0 2) Access Module Large Access/Blank Module Insulation 2 "(51 mm) Solid Dble Wall Door Right Hand Fan (Pos 03) Fan Module Insulation 2 "(51mm) Solid Dble Wall Door Both Sides 12B -Fan Size 15" (382,6mm) F.C. Spring Isolation Fan Discharge, Front - Top Drive Right Hand 1.2 Variable Drive 10 Horsepower (7.457kw) ODP HI Efficient E+ Motor Voltage 480/80/3 RECEIVED CITY OF TtJKWJ'.t JAN 19 2000. PERMIT CENTER FLO R Furnished by Trane / Installed by Others Trans Submittal Page 3 of 12 Zama Networks Performance Data Ta • s TSCX4 Unit Level Position #0 Actual Air Flow (cfm 7820.0 Elevation Relative to Sea Level (ft) 0 Unit Length (in) 136.500 Unit Height (In) 45.750 70.000 Unit Width (in - •. n, rn "eg w: 1670.0 Installed Unit Wei s ht lb 1668.0 MIN MN. 11111111111111111111111111111111111111111.111111111111.1111111111111 11Z111111111111111111111111111111111111111111111111111111111111 Position Fan Air Flow c m 7820.0 External Static Pressure in H2O En= 3.41 o a - a is - ressure mativimminum Seed r•m 1310 BHP h• 8.213 Access Position #2 Additional Static Pressure in H2O 0.00 • P u e t.en ! th In 34.000 USITITIVET t b 232.0 Mxn� Poston 1 Bottom • • en n r - low 7820.0 = at om ntty • ressure 'rop n ' • 0. • • Back 0 • enfn • Alr Flow cfm 7820.0 = ac n - ressure ' ro • n Bac Ent Pressure Oro. n H2O 0.41 0 - 4 0 nt - ressure ro • 11;11:Ft ) 0.00 e = • to Ent Pressure Dro • n ' 20 0.00 - . t • e nt - ressure 'ro • (fi'FZ) 0,' 0 R 1 Side Ent Pressure Dro • In ' 20 0.00 ter A r ow - ' • m 78 0.0 Filter A r Flow - AM dm 7820.0 ustomer u • e • ter - ressure Dro • IIINNINIII 0.7 C ustomer Su • • e • F ter Pressure Dro • In '20 0.75 ustomer = u • • e • ter • rea ccia 18. 0 Customer Su • • ed I ter Area s • 18.70 o a • er = ressure + ro • Il7.kt %) ` • ota ter Pressure Dro • (i7a%n•) 0. 6 ota ' x n, = ox - ressure Dro • II7.FZ•) Tota M xin • Box Pressure Dro • In 20 1.16 vintlitimin 34.000 ,7 • 4t1= - I ! 34.000 492.0 r i ..iTQ?Yajrilh1I! Mo • u e e , t (lb) 492.0 December 14, 1999 RECEIVED QF TKW►, A FLO R Furnished by Trans / Installed by Others Trane Submittal Zama Networks Mechanical Specifications - Ou or Central Station Air Handler Units Item(s): Al Qty: 1 Tag(s): TSCX -1 GENERAL The units must be rigged and lifted in strict accordance with the Installation Operation and Maintenance manual (CLCH -IM- 16). The units are to be installed irTstrict accordance with the specifications. Units may be shipped fully assembled up to nominal 40,000 cfm units or disassembled to the minimum component size according to shipping or Jobsite requirements, Units shipped in one piece will have no more than 6 points of lift required, These lift points will be permanently attached to the unit base and be designed to accept standard rigging devices, Units shipped In sections will have no more than 4 points of lift required, Units are UL and CUL listed L1995, CSA C -22,2 as manufactured by the factory. Modifications to the units at the Job site or by a third party may void this listing. Refer to the Product Data Sheet for door and drain pan connection locations. This mechanical specification describes options selected from all or Just one of the T- Series units on the Job, Unit Construction The unit panels feature galvanized steel double wall construction. The casing Is able to withstand up to 8 Inches of static pressure with no more than 0.005 Inch (0,127mm) deflection per inch (26.4mm) of panel span. The unit base design allows for field installation on roof curbs. The entire length and width under the base Is sealed for additional water management protection, Panel Construction Panels feature solid double wall construction with totally enclosed closed -cell insulation providing a minimum R -value of 12. The insulation conforms to NFPA 90 requirements. Access Doors Access doors are fully insulated double -wall construction (with solid galvanized steel interior panels). Automotive style neoprene gasketing around the full perimeter of the access doors minimize air leakage. All access doors have a single door handle system. The first handle movement relives unit pressure. Unit Roof Unit roof is constructed of two pieces, Inner roof is installed in such a manner as to prevent air bypass between internal components. Outer roof is sloped either from one side of unit to other, or from center to sides of the unit. Roof assembly overhangs all walls of units by 2" (50,8mm) minimum, Unit Paint External surface of unit casing Is coated with a minimum 1.5 mil "executive beige" enamel finish. Units painted In the factory, are able to withstand a salt spray test In accordance with ASTM B117 for a minimum of 600 consecutive hours, MIXING SECTION A section is provided that supports damper assembly for outside, return, and /or exhaust air, Dampers Dampers modulate the volume of outside, return, or exhaust air, Dampers are Ruskin CD-60 with double skin air foil blades, ultra low -leak metal compressible Jamb seals, and extruded vinyl blade edge seals. The dampers are rated for a maximum leakage rate of less than 1 percent of nominal airflow at 1 inch wg. Blades rotate on stainless steel sleeve bearings. Dampers are arranged in parallel or opposed blade configuration. Inlet Hood Inlet hoods are provided with high performance moisture eliminators to minimize water carryover from December 14, 1999 the outside into the unit casing. Outlet hoods are provided on exhaust air openings. BLANK /ACCESS/ INSPECTION Additional unit length is provided to allow extra interior space for, access to, or inspection of unit components. This section may also be used for field installed components. FAN SECTION Fans are factory balanced, Fan shafts are solid, protectively coated with lubricating oil, and designed so fan will not exceed 75 percent of the first critical speed at any cataloged rpm, Fan wheels are keyed to the Shaft to prevent slipping. Access doors are provided on the drive side of the fan section, Forward Curved Fan The forward curved (FC) fan Is a double - width, double - Inlet, muitiblade type as required for stable operation and optimum energy efficiency, Bearings are self - aligning, antifriction bearings with a L -50 life of 200,000 hours, Fan performance is certified In accordance with ARI Standard 430.89. Motor Voltage 460 Volt / 3 Phase / 60 Hz.(Refer to the Product Data Sheet) Open Drip -Proof Motor The motor Is a T- frame, squirrel cage, open drip -proof with horsepower, type, and electrical characteristics as shown on equipment schedule. Motor Is mounted inside the unit casing Integral to an isolated fan assembly. A slide base permits adjustment of drive belt tenslon..(Refer to the Product Data Sheet) Variable Pitch Drives Sheaves are variable pitch, suitable for adjustment within 5 percent of spe lc i�d rpm. CITY OF r' FL-O Furnished by Trane /Installed by Others Trane Submittal J9N1 ;) /r►11D. Page 6•of 12 PERMIT CENT ak 3 Wt Og Fan Isolation Two Inch (51.8mm) Spring Isolators - Fan and motor assembly (sizes *10 • #100) is internally isolated from the unit Zama Networks casing with 2 inch (51.8mm) deflection spring isolators. The fan discharge is also isolated from unit casing by a flexible canvas duct. The isolation December 14, 1999 system is designed to resist loads. produced by 'Memel forces such as earthquakes and conform to the current requirements for Seismic Zone IV. RECEIVED CflV QF TUKWH I JAN 19 2000 PERMIT CENTEk Zama Networks Unit Dimensions (Page 1 o1 1) • ltdoor Central Station AIr Handler Unit Item: Al Qty: 1 Tag(s): TSCX -1 December 141999 CITY OF TUKWILA JAN 19 2000 PERMIT CENTER FLO a Furnished by Trane /Installed by Others Thane Submittal Page 7 of 12 Zama Networks Accessory - Outdoor Central St )n Air Handler Units Discharge Detail Item: Al Qty: 1 Tag(s): TSCX -1 t1 40.. y as- December 14,1999 4 4 1 1 1 1 RECEIVED CITY OF TUKWILA JAN 19 2000 FLO PERMIT CENTER Furnished by Trane / Installed by Others Trani Submittal Page 0 of 12 Zama Networks December 14, 1999 Accessory - Outdoor Central a m Air Handler Units Drain Detail Item: Al Qty: 1 Tag(s): TSCX -1 p m <ii iiiiiiiiii : li I,F6 1 1 aaa i i i CITY OF TIo vG JAN 1 9 ?000 -F LO by Tmne / Installed by Others Traniramittel PERMIT CE 1 t . Ape9ot12' Zama Networks Accessory - Outdoor Central St in Air Handler Units Unit Clearance Detail Item: Al Qty: 1 Tag(s): TSCX -1 December 14, 1999 r 1 L J CITY ORECEIVE() " JAN 19 2000 PERMIT CENTER FLP ■ Furnished by Trans / Installed by Others Trine Submittal Page 10 0112 Accessory - Outdoor Central SI Filter Schedule 03 - 21 Item: Al Qty: 1 Tag(s): TSCX -1 Zama Networks 'm Air Handier Units Filters Unit Size 12 An . ied LME 16,70 2 " PM Q . Perm IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 6 -20 "x20" For Reference Only, Not all units selected Include above filter modules or unit sizes, Unit will require field modification to 4" filters, CUIY QR T�UKWH e JAN 19 2000 PERMIT CENI'EI, FLO to Furnished by Tuna / Installed by Others Trani Submittal Page 11 of 12 Zama Networks Accessory - Outdoor Central Sty ;i Air Handler Units Size 12 Door Detail Item: Al Qty: 1 Tag(s): TSCX -1 A -A B -B December 14, 1999 • 1, For Reference Only, Not all units selected Include above modules. Re er to Unit As -Built to determine modules with door(s) and location(s), 2. Door opening Is equal to Door Height minus 1 1/2" and Door Width minus 1 1/2 ". CITY OF TLJKWrr e JAN 19 2000 PERMIT CENTER FLO • Furnished by Wane / Installed by Olhors Trane Submittal • • • ' ' Page 12 of 12 Module A B C D -A Filter- xing Box 22" 37 1/2" Mixing Box 22" 37 1/2" B -B Fan TTP 37 1/2" Contro s -22" 161/2" 1, For Reference Only, Not all units selected Include above modules. Re er to Unit As -Built to determine modules with door(s) and location(s), 2. Door opening Is equal to Door Height minus 1 1/2" and Door Width minus 1 1/2 ". CITY OF TLJKWrr e JAN 19 2000 PERMIT CENTER FLO • Furnished by Wane / Installed by Olhors Trane Submittal • • • ' ' Page 12 of 12 System Data: Indoor OS LCT OA CFM/per, Peo. Div. Static Press wg Fan (D ore) Fen/Motor elf, Roof if 450 Net wad sf 18,398 Glazing sf (w /o Skylight) 1,584 % 01/wall 9.2% low s,. n« Sys,' Sys.2 Ir rw err rw Sys.3 Sys.4 WtetLOONY 2NC6/C 72•F 55°1 20 100% 3.00" DRAW 72•F 55'F 20 100% 3.00" DRAW 7S•F SS•F 20 100% 4.00" DRAW 75•F 55•F 20 100% 4.00" DRAW AutoReca ZAMA FILE C,OPY Recap by: Ching Wong FILE: C:ZAMA12.CHD Version: 7 PATH: ,.„ Joesntii .2tANAn.n.,+,r..sumuttera INPUTS Envelope Data Sys.5 Sys.6 Wan Insul: 2N0 TEMP WC IIM Roof Insul: 150F 72•F Partition: 5S•F 550E Watt Height (11): 20 20 Ceiling Height (11): 100% 100% Glazing: 4.00" 3.00" Type: °RAW DRAW tMnter U•Value: Summer U•Value: Shading Coeff,: 0 0 Iiternhl Load Data tbefaultsL. 159 SF/Person: 12,189 Diversity ( %): Equipment (W/SF): re tints toe IN Ughting (W/SF): 1.20 1/0 In8, AMR 80% 80% 80% 80% 80% 80% LTO. W/SF: 1. Equip, W/SF: 48.0 SF/Person: 140 Pao. sens(btu) 280 Poo, lat(btu) 200 20 1,20 C9nllea Skyllghl sf Exposed Floor Perim. (LF) People qty Exposed Floor (SF) M tMiff 240 VC 48,0 140 260 200 1.20 1.9 140 260 200 1.20 1.5 140 260 200 • CHO Crested. 9121140 CHR Ctut d: 1213199 (u•v.aw r• 'view) Weather Deal: Tukwila.WA. R•11 R•30 R•19 0.140 U Outdoor Summer DB: 0.038 U Outdoor Summer WO: 0.053 U Outdoor Winter 08: 13.0 Indoor Winter DO: 13.0 Indoor Summer DS: A5 0 Area Area Peak Sensible Total Sarwd CFM OTUH OTUH 1 WIWI 10,204 129,044 2498,384 2,411,003 2 sass 7,882 03,674 1,600,405 1,503,521 3 MOOmar 1,140 2,204 52,600 00,053 4 moon 1,065 3,318 85.003 101,765 6 salon. 7,014 0,300 137,401 151,720 8 Nos Norm 340 2,042 40,020 60,034 1.9 11137 W 0A CFM PER PERSON 140 140 Sensible safety factor: 250 250 Latent safety factor 200 200 Heating safety factor: Cooling 741 Heating T40; Enter 1 gross dross 85•F 67°F 17, 70'F 726F tree tts,t try.t try. rot_ 0.50 0.50 0.50 0.50 0.45 0.45 .,. 01 6% 20% 17•F Based on First 40-1 Partition_ O�ffr r, Tons to deIela Sens, Total (flock Oross CFM Sens CFM/ 8F1 CFM/ tone Lot. STUN %OSA 07U11 CFM Tons Diver. ratio BP Ton Ton 201.0 2,308,344 0.5% 2,411,003 124,288 130,3 1,660,455 0,4% 1,663,621 03,302 5.1 62,009 22,7% 60,063 2,204 e,0 86,003 303% 101,746 3,345 12.0 137,401 13,1% 151,720 0,200 4 2 40,620 1,014 60,834 2,042 0.0 0 0 0.0 0 0 0.0 0 0 0.0 0 0 Total 34,313 227,130 4,270,432 4,34 0,464 301,7 60,3 713,305 1,0% 723,411 4.270,032 1.011 4,340.404 0 Per unit NMYoa Na e AS8 Served 1 tors, 2 moss 3 NRStWWIY 4 Poore 6 so fur 0 *MOM 6,710 37,066 713,305 . 723,411 . Zone Healing Hooting Ana Lose Infiltration H Outside Alf lot1 Heating Heating Zone Total InIIIV, Outdoor Plenum • 141g 14 sir % Loss Out, Ak OTUH lr 10.8 0 144,109 330,713 904 00,4 104 0 04,003 120,230 30,7 64.0 30,3 0 42,053 94,204 27,0 20,0 00.9 0 90,424 120,233 37,9 40.4 32.1 0 00,883 140,298 42,9 0.0 100.0 0 2,105 2,795 0.0 0.0 0.0 0 0 0 0,0 0.0 0.0 0 0 0 0.0 0.0 0.0 0 0 0 0.0 0 0 0.0 49.0 24.8 0 420,727 830,639 245 40.0 24.5 0 71,121 130,423 41 1 ,244 7,002 1,144 1,065 7,014 340 0 0 0 107,001 36,207 14,132 22,040 30,011 0 104,004 70,073 61,011 33,009 69,416 0 30,.,. 10,398 20,021 73,544 47,002 2,705 2010 130.3 0,1 8.5 12.0 4:1 0.0 0.0 0.0 0.0 0.99 1,00 1.00 1,00 1,00 1:00 0.00 0.00 0,00 0,00 0.004 0.098 0.805 0.130 0,000 0.060 0.000 0,000 0.000 0,000 7.87 01 50 220 210 666 00 0 0 0 0 10.87 1.02 141 0.00 7,77 000 000 0.00 0.00 038 830 434 397 400 024 0 0 0 0 220.008 301.7 1.00 0,106 0 60 06 025 37,003 00,3 1,00 0.908 0 09 05 020 Total HIg HI9 OTU/ KW SP 20,0 10,3 02.1 09,7 20,9 0.2 0.0 0.0 0.0 Total 34.313 210.921 409.012 207400 0 Per unit 5,710 34,487 08,302 34,034 HTO (intoring Cooling OA Coll CFM 05 WU A58 040 340 600 1,290 024 49 72,05 72.04 76.02 70,07 75,13 72,20 00.10 1 00,10 03.68 3 64,29 4 02.00 0 00.20 0 2 CLO oA CFM 040 340 000 1,290 024 40 11 2ffx.oILf • 1 H.MA0V0115133340 ZAMA N..r.r1 4.01044 ∎HAl2•R.c.p.+4 1111100 8:12 NI 24.4 3.643 74.39 01.06 3,643 24.4 007 74.39 01.00 RECEIVED CITY OF TUKW1t_A JAN 19 2000 PERMIT CENTEP 1 1 • • • . e•: . 5A..t ZAHAI2 Pp.; 1 0 1 1g i; • F'!. . SUMO ZAMA NNwo 1tILoada 12 H•.tlnp -Loss Sans. O.n 'latent Ow 1 M- CFM . CLO 01 i -bra-a WO. 0l0 o -CFiri ExH - C€ii- HTS- `Cr:M/Sr ``CC•7 --a-I P ion. • 6. `kWV Cole kW Inf1 Cfir` t` 0 • . •..."- P't New - 1 '"'r- 1 • JULY • J1 1 . `fib- 0880 17511 `26-foo 1229821 2940 -715 8 1 -iO4i- 73882 -1442` 2e0 280 0 0.09 10.73 1 1ST WMOdot _ 5.134232 6 o ^3i"- 73662 "• 163S74- 'wbi ie9- lISS01- 1441139 65- 6577 ---- f-4 3" ""S6if -- - 64765' 2d3- --42b-"" -�"' --6666 -3116 - "'•33373"•"666- 40 40 t2o o o 1.31 CIO- -1-91, 1 tiff- 2 ' 3-- 4 -`w --6-- 6_ -•W.i P•sk Totals- -t.07`- 8164661 -3O io7fo 1:364362 _0.-1i�MMfi 31:63266 66.57122` ' O 12 -33W WWI --- 1' + OA `" • ritiii4iCiirr, VIP - .4 a 611M ALLY 6-13if �1"Y -' 6' 1Lir -_ .. f"- " i- -6166- `410 - 1047 62-' 1365- eta "2f6 -MCI" "'-40 b` lob- 40 o -166-- 0 tai" 8.06 _TO-- -Old- 6.33 66_ .-.. - . EI.v Uobbr7boit; UP9 '- 6 6269 `213 ` - 3640._ - -".. r -_ __ -� __ _. .. - - -. -..._ _ ....__- 0 0"` - °f'.- `!1`" •14N 0 1 302205 2148031 70720 11232 1 9044 040 840 0 119 124014 A1ifEV6TEM �. :. t�. 1 . .. -i- ._ .. f . . . .�.._._ . ._.... . �.. . aY i" _ ._v. _ frno ' JUt. iOAMM7UtV - MCA.' IOAMJUl! . 6 0 RILY - - tei ._ 101 3oO '761,... • 1111! tai .. T_ i. "-Lou _s ' 1 lee 4i3 - - <I6'2or"366416` -2676: ' `17744` °• 0-. _ . _ . �+,� • - 3 ` 30- - '143 3( `270107` -Mite _ ''urm: - -0 �-Htcs- -01.4-- - era -CrM- w H7tf. -6A CfM CIa '--OA`Crbt F� -Cali �i� - 01:44F` - - - - -- - - - - - -- tun.. b.seiywon 110 22n4Ni -TJ.238225 . ii 2rr i� __ i2`_' 11414r------ {3`- 2i1.112".�`."_ `14 ` 2No..W _ __. 1r�`u 211D.iNT -` -- - -_ iWL.i-149111 12660E - 30i ?$N6 f.6462S6.�...6.`.- ii 00666 _ - -- ,n 0- -_2__ - ,._4 -.. -14 -------'------ _C 0T 6666' --' - i2i6..;: -OW _ 66601 "i7041- ____.� -_v . 4 ._ -- --- �._ - • _ -... - �� ......_..�._ _ 1• ' f 4 1 R �. _.__ _�..... ;...u..,.1 1 fid61__ 2N0.N2 , 2660`612 '. SW '• L' HTa `cfMisri 0 _ ii - "210" -' -"f20" 630" -- flit - 064 _ i i f63" j`P11 -- 1716 ..`'b 6611 _- f24i-- "32611- 161 ` -*WC ` 47111' 20 ..X6'_"_26.... --20- -46'-• 00 _ ""°666..` 20 `--2O "`40 _. 80_. `160 0 _ "o 0__ -11-- .�_Ol "if ` 1.29 __1.4 _ - _ -i:21 • f.26 1:2 . 0- • 1094 ;f a" w_._.._ `"10'41" _�... -. . -1124 _._..�._.. 'I 6.51 J' iO6f `�. _ . 1`P6i' 0 0 •if.:I 10 . 1 '' `' ' st. �� ,. 1 31,01993 32 74 .� _ .._. _> __..___._. • _ . it!?rt ... Gt�AL. 1`iTo7 -01:0= u`"rf0.....�.CCO�.` °"_Exi6` --11T0 "' F. co ...I. - .. _ . ,.. .. �Y �..a.� ,� } • ..1 t .. • ; 20'" t0� o a �o . :Mr aIl6>i" 40 _,_1010 tar 6 "o 123° {2ZQ 73 CO -IoC _ 00 10P az,00 .0� 0 0 �0 .. 040. y '-17- 21iOIi LOD O,�� . r11 3R.D1NTIO0 6 7 1�„ 2Na1NTve �� 0 r0�= o 0..:` 0 Q.@o •...i12- 12L= 7 -- -... ,a.�,_..�,•.- tea.. ... .. ..._.,._< `` A. 1/ 491.1 ILL t ':.I it li.�� r ; r� • .:1. _., v..�, - -"- 'il:.fl ,a�... yi•Fir i.� , Joe- M ' _co- r - - -..". _ _- -- --__ -_ , • _ . - - • _...._ - Ca I i 11" �" 1 "' 1! i� , . 01, • , 1,1'.T .34 . _01� 00 110 . _._'... _ti_ ._ _ ITO i' •.. ass'. • "°Exit"¢ F , YO r F . CLO. - _„ :� a> • oe DMs :1340-0476- 3 13 62 �t4S1= 6091 _ 7411 ' 61066 01301_ 1109 7031 -- .. 1. - 26/1" �`33) '316° .370 - 6107 _ • 12� 10_ -lair ..,.,.... 10211m 602+1' :WO- .1147 10912' , 30171. 1439 _- • :1, _ ` , ° �l 'Y "" ,,. N • .y. 1 l _ 1 l IF F . - 1 ' - 443 •211 164 -160 600 -our 16606" 5111-' ' 701 � . 0 162 ` 11th 6466 1240 7101_•„ . 4151, 03 "to60" -2100" 214- ...: 2940�,,�0' 610 o/1' q11= 217 a2 1 `664` -`7 2- -21r ' 370 410 100 .'100?' u. 04 -22 • SS � 416 _ .49 24 ®,. X211 "100 = .200 22 - ,t2,.a -4$0 19 _-�.20� 20 _.` 0` 0'�" °-0- ..,. o • '-'�0 0 0 0 "x;16". -'229' 119 -Tor rz_ 0 0 0 -T 1.34 "2.64. , YS t 01 -.-2-4f- 'Fi�03 X641 03Z, 1.95- ��,.,a .�•`: 7- ip TOH1 31702 3 F 2I"_' RtAP( n °2i- WAR.jt9QA17 ""�23"' OIC •� --- OFC .-:. -26 CQNF �� 724. HOC .t -.. _21 �,CORRIDQIj.. Q 3d rC • 2 7 »� a 1111N�0 i'r112$Q 2 0013 0 0 10060 7 �"3 ,6 - =`.,.Q'=' '�'2- ,�"3.�..:„31O ""0�' 0` - - oIe "� "-hr. -or - '°630 n1007 - j s v u. '- i • 2 ,.4... 1 2t . . • • • • 1.PM,J �' 41'441! Y 4!'M.jVI•Y.__ �P Q 0 _ _i 111 iso 4 •• _ 201 _ 76- 1! _..40 361 0 "T? 40 6 P IV i • 0760 70 ._..... -Off � 430 11014 7407 �1 104W 41"I �, • 'Ill :•a 1L2 �'.:_ ,{':1 L_ in '� >fi'�i! -: ? -- -T-.- k.`_ --- ,�,..- kW-1A - - FM ..270'6- 117 .114104 --. ''. _. , T .� - --- . ...�- __ r �y .. _rs T ' __.ci.07 • FM 1:114 F . F CLOT F -r.... . jj, . °29 30 •-3i 32"' -3� -t.s- .777 • _- -.Lt.; _ �_... .HI$na. ,j0.04.; _,,.!•1l0(1l. • ' sin _ 1TQ.. FM __CLQ _ FM �lTQ-- • FM --1RXH;_. FM ,-,.-_- �"' '..a . .. At a " �� i L i._ !.: • Ze.., 1: _ s .. -t 1 T �7 � 16 , 30 ' 1041 2324'"' . X109 1120 .o 1191 0 11160'" X702 1.31 0 ono_ -21102_,--4----00 603` ' .� ,01� X001 1604 .1--__--7.0 179 T064 1600 _ _143 m014 2090 �61 T�' 0 01 -149- 332 -�61. _o------0 4i t 149 332 `o- - n�201 0 0 - :36._ .._.:3:00 • 1719 :12 11 . 1Of.... ------ 4.600 --, r oBNTRY 40PC � 0. li PERIM -' OPEN INT 9161n 1X111? 0.710911 12.30217 0 -._T 2 ---7- _ 13 0 W. ""� 19AM y Y ... 1iAM�ilLY T, , � .iyi.__. . LAS __ .. , - 0¢/ a 2090 1451 { PLItIM- OPEN INT QORRI0o t t07.04 4�(Y 110,44 Y ` 2 , 003- - �. .- ,.,- ...,- 1 0 1461 0 - • - - 1 PM L 1 ' 1 1 1 X110 160 0 0 2467 1011 670 0 127 64 64 0 0 0.33 34 CORRIDOR 0 0 127 �'� " ," , OFC ILPMJU Y SPa,1VLY PM JU Y 6 PM JULY 226 0 94 • 21 21 0 0 003 35 OFC 'T' 0 94 1¢Q_ 737 0 0 1614 4703 226 1100 0 0 94 247 21 105 21_ 105 0, 0 0 0 003 30 QFC 041 37 MAIN CORR __0 0 0 0 0 0^' 0 91 247 290 - 7 31 MAIN CORR 2ND CORE 1 - ' 1240 O 6581 0 0 290 0 0 0 0 0.23 30 2ND CORE 2TAL 1 '' TOTAL 14 Yti CIALK440 Y'/' 6w.4YM1i.11.61J AUn 11, vim II II Lid PACE CONSULTING 5005 3RD. AVENUE SEATTLE, WA r`` 67 rr:G GROUP SOUTH 98134 FULL COMMERCIAL HVAC LOADS PROGRAM BUILDING DESIGN MONTH JANUARY MARCH JULY WINTER MASTER DATA OUTDOOR DRY BULB 54 61 85 17 ROOF ASHRAE ROOF TYPE ROOF N U -FAC 1. 5 0.038 AND DESIGN OUTDOOR WET BULB 48 49 67 0 PARAMETERS: ROOF SUSP COLOR CLO. DARK YES PART PART COOL HEAT TYPE U -FAC T -D T -D 1. 0.053 17 40 WALL ASHRAE WALL WALL TYPE GROUP U -FAC COLOR 1. 0 0.140 DARK GLASS SUMMER WINTER GLASS NO. U -FAC. U -FAC, SHD.COEF 1. 0.500. 0.500 0.450 2. 0.500 0.500 0.450 GENERAL PROJECT INFORMATION: I. a/4 GA Leif LA 71 o") PROJECT: CLIENT: DATE: DESIGNER: INDOOR .INDOOR REL.HUM DRY BULB 50t 50t 50% 50% INTERIOR SHADING I . r ZAMA MCKINSTRY COM)ANY 09/21/99 MSH GRAINS IN /OUTDOOR DIPP. CORRECTION 75 -24.73 -39 75 -32.33 -32 75 5.64 -8 70 0.00 MCet( . uifr7' TAl� LoAD a/I L4k LA POP) Baia $010/4 .....14awnimmaaas mamas >ASi It. $ I�NP -3 7k,t41 7 ----> A SO 'i GRu• 141 Ifs4. 6 INTERIOR SHD.COEF ROOM GLASS GLASS CONBT WIDTH HEIGHT NO 0.000 LIGHT NO 0.000 LIGHT PROJECT FILE NAME: PROJECT LOCATION: BAROMETRIC PRESSURE: ALTITUDE; NORTH LATITUDE: MEAN DAILY TEMPERATURE RANGE: ATMOSPHERIC CLEARNESS FACTOR: GROUND REFLECTANCE: STARTING TIME FOR HVAC LOAD CALCULATIONS: ENDING TIME FOR HVAC LOAD CALCULATIONS: FLOOR HEAT LOSS COEFFICIENT: NUMBER OF UNIQUE ZONES IN THIS PROJECT: C :ZAMA12 Tukwila,WA 29.817 IN.HG 96 FEET 47 DEGREES 22 DEG.F 1.00 20 PERCENT 7 AM 8 PM 0.81 BTUH /FT -F 39 1.00 5.20 1,00 7.75 RECEIVED CITY OF TUKWILA JAN 19 2000 PERMIT CENTER * ** FULL COMMERCIAL HVAC LOADS PROGRAM BY ELITE SOFTWARE DEVELOPMENT INC * ** PACE CONSULTING GROUP SEATTLE, WA 98134 ZAMA 09/21/99 PAGE 2 * * * * * * * * * * * * * * * * * * * ** GENERAL PROJECT DATA (CONTINUED) * * * * * * * * * * * * * * * * * * * ** BUILDING DEFAULT VALUES: CALCULATIONS PERFORMED: LIGHTING REQUIREMENTS: EQUIPMENT REQUIREMENTS: PEOPLE SENSIBLE LOAD MULTIPLIER: PEOPLE LATENT LOAD MULTIPLIER: PEOPLE OCCUPANCY BASIS: ZONE SENSIBLE SAFETY FACTOR: ZONE LATENT SAFETY FACTOR: ZONE HEATING SAFETY FACTOR: PEOPLE DIVERSITY FACTOR: LIGHTING PROFILE NUMBER: EQUIPMENT PROFILE NUMBER: PEOPLE PROFILE NUMBER: BUILDING DEFAULT CLO. HEIGHT: BUILDING DEFAULT WALL HEIGHT: INTERNAL OPERATING LOAD PROFILES (C ■100): BOTH HEATING AND COOLING LOADS 1.20 WATTS PER SQUARE FOOT 1.50 WATTS PER SQUARE FOOT 250 BTUHS PER PERSON 200 BTUHS PER PERSON 1 PERSON PER 140 SQ.FT 10t S4 20% 100t 1 1 1 13.00 FEET 13.00 FEET REF HR HR HR HR HR HR HR HR HR HR HR HR HR HR HR HR HR HR HR HR HR HR HR HR NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1. C C C C C C C C C C C C C C C C C C C C C C C C 2. C C C C C C C C C C C C C C C C C C C C C C C C 3. C C C C C C C C C C C C C C C C C C C C C C C C 4: C C C C C C C C C C C C C C C C C C C C C C C C 5. C C C C C C C C C C C C C C C C C C C C C C C C 6. C C C C C C C C C C C C C C C C C C C C C C C C 7. C C C C C C C C C C C C C C C C C C C C C C C C 8. C C C C C C C C C C C C C C C C C C C C C C C C 9. C C C C C C C C C C C C C C C C C C C C C C C C 10. C C 'C C C C C C C C C C C C C C C C C C C C C C ALL DESIGN DATA TAKEN FROM THE 1989 ABHRAE HANDBOOK OF FUNDAMENTALS CITY OF TUKWILA JAN 19 2000 PERMIT CENTER * ** FULL COMMERCIAL HVAC LOADS PROGRAM BY ELITE SOFTWARE DEVELOPMENT INC * ** PACE CONSULTING GROUP SEATTLE, WA 08134 ZAMA 09/21/99 PAGE 3 * * * * * * * * * * * * * * * * * * * * * * * * ** AIR HANDLER INPUT DATA * * * * * * * * * * * * * * * * * * * * * * * * ** AIR HANDLER # 3 INPUT DATA: AIR HANDLER DESCRIPTION: TERMINAL TYPE: METHOD FOR CV: SUPPLY PAN TYPE: CALCULATIONS PERFORMED: EXCESS SUPPLY AIR: NUMBER OF TIMES SYSTEM OCCURS: LIGHTING PROFILE NUMBER: EQUIPMENT PROFILE NUMBER: PEOPLE PROFILE NUMBER: EXHAUST CAN EXCEED SUPPLY AIR: LEAVING HEATING COIL TEMP. (DEO.F): DRY BULB TEMPERATURE (DEG.F): COOLING COIL CFM: MISC. BTUH GAIN - SUPPLY SIDE: MISC. BTUH GAIN - RETURN SIDE: COMBINED FAN,MOTOR EFFICIENCY (%): STATIC PRESS. ACROSS FAN (IN.WO): SUMMER SUPPLY DUCT TEMP. RISE (DEO.F): BUMMER RETURN DUCT TEMP. RISE (DEG.F): WINTER SUPPLY DUCT TEMP. DROP (DEG.F): WINTER RETURN DUCT TEMP. DROP (DEO.F): CHILLED WATER TEMP.DIFFERENCE (DEO.F): HOT WATER TEMP.DIFFERENCE (DEO.F): COOLING VENTILATION METHOD: COOLING VENTILATION VALUE: COOLING INFILTRATION METHOD: COOLING INFILTRATION VALUE: HEATING VENTILATION METHOD: HEATING VENTILATION VALUES HEATING INFILTRATION METHOD: HEATING INFILTRATION VALUE: VENTILATION IS 1001 OF SUPPLY AIR: PRETREATED OUTSIDE AIR: IGNORE PRETREATED LOAD: PRETREATED AIR SUMMER DB TEMP (DEG.F): PRETREATED AIR SUMMER WB TEMP (DEG.F): PRETREATED AIR WINTER DB TEMP (DEG.F): DESIGN MONTH JANUARY MARCH JULY WINTER OUTDOOR DRY BULB OUTDOOR INDOOR WET BULB REL.HUM WEST LOBBY VARIABLE AIR VOLUME SUM PEAK ZONE CFMS DRAW -THRU BOTH HEATING AND COOLING LOADS RESERVE CAPACITY 1 1 1 1 NO 95 55 0 0 0 60 4.000 0.000 0.000 0.000 0.000 0.000 0.000 2 20.000 CFM PER PERSON 0 0.000 2 20.000 CFM PER PERSON 1 3.000 AIR CHANGES PER HOUR NO NO NO 0 0 0 INDOOR GRAINS IN /OUTDOOR DRY BULB RIFF. CORRECTION 54 48 50V 75 - 24.73 -39 61 49 50V 75 -32.33 -32 85 67 50V 75 5.64 -8 17 0 50V 70 0.00 RECEIVED CITY OF TUKm A JAN 1 9 2000 PERMIT CENTER * ** FULL COMMERCIAL HVAC LOADS PROGRAM BY ELITE SOFTWARE DEVELOPMENT INC * ** PACE CONSULTING GROUP SEATTLE, WA 98134 ZAMA 09/21/99 PAGE 4 * * * * * * * * * * * * * * * * * * * * * * * * ** AIR HANDLER INPUT DATA * * * * * * * * * * * * * * * * * * * * * * * * ** AIR HANDLER # 4 INPUT DATA: AIR HANDLER DESCRIPTION: 2ND OFC TERMINAL TYPE: CONSTANT VOLUME METHOD FOR CV: SUM PEAK ZONE CFMS SUPPLY FAN TYPE: DRAW -THRU CALCULATIONS PERFORMED: BOTH HEATING AND COOLING LOADS EXCESS SUPPLY AIR: RESERVE CAPACITY NUMBER OF TIMES SYSTEM OCCURS: 1 LIGHTING PROFILE NUMBER: 1 EQUIPMENT PROFILE NUMBER: 1 PEOPLE PROFILE NUMBER: 1 EXHAUST CAN EXCEED SUPPLY AIR: NO LEAVING HEATING COIL TEMP. (DEG.F): 95 DRY BULB TEMPERATURE (DEG.F): 55 COOLING COIL CFM: 0 MISC. BTUH GAIN - SUPPLY SIDE: 0 MISC. BTUH GAIN - RETURN SIDE: 0 COMBINED FAN,MOTOR EFFICIENCY (4)s 60 STATIC PRESS. ACROSS FAN (IN.WO): 4.000 SUMMER SUPPLY DUCT TEMP. RISE (DEO.F): 0.000 SUMMER RETURN DUCT TEMP. RISE (DEG.F): 0.000 WINTER SUPPLY DUCT TEMP. DROP (DEG.F): 0.000 WINTER RETURN DUCT TEMP. DROP (DEG.F): 0.000 CHILLED WATER TEMP.DIFFERENCE (DEO.F): 0.000 HOT WATER TEMP.DIFFERENCE (DEG.F): 0.000 COOLING VENTILATION METHOD: 2 COOLING VENTILATION VALUE: 20.000 CFM PER PERSON COOLING INFILTRATION METHOD: 0 COOLING INFILTRATION VALUE: 0.000 HEATING VENTILATION METHOD: 2 HEATING VENTILATION VALUE: 20.000 CFM PER PERSON HEATING INFILTRATION METHOD: 1 HEATING INFILTRATION VALUE: 1.500 AIR CHANGES PER HOUR VENTILATION IS 10011 OF SUPPLY AIR: NO PRETREATED OUTSIDE AIR; NO IGNORE PRETREATED LOAD; NO PRETREATED AIR BUMMER DB TEMP (DEG.F): 0 PRETREATED AIR SUMMER W8 TEMP (DEG.F): 0 PRETREATED AIR WINTER DB TEMP (DEG.F): 0 DESIGN OUTDOOR OUTDOOR INDOOR INDOOR GRAINS IN /OUTDOOR MONTH DRY BULB WET BULB REL.HUM DRY BULB DIFF. CORRECTION JANUARY 54 48 5011 75 -24.73 -39 MARCH 61 49 50%r 75 - 32.33 -32 JULY 85 67 501 75 5.64 -8 WINTER 17 0 50% 70 0.00 RECEIVED CITY OF TUKWILA JAN 1 9 2000 PERMIT CENTER * ** FULL COMMERCIAL HVAC LOADS PACE CONSULTING GROUP ZAMA * * * * * * * * * * * * * * * * * * * * * * * * ** AIR AIR HANDLER # 5 INPUT DATA: PROGRAM BY ELITE SOFTWARE DEVELOPMENT INC * ** SEATTLE, WA 98134 09/21/99 PAGE 5 HANDLER INPUT DATA * * * * * * * * * * * * * * * * * * * * * * * * ** AIR HANDLER DESCRIPTION: TERMINAL TYPE: METHOD FOR CV: SUPPLY PAN TYPE: CALCULATIONS PERFORMED: EXCESS SUPPLY AIR: NUMBER OP TIMES SYSTEM OCCURS: LIGHTING PROFILE NUMBER: EQUIPMENT PROFILE NUMBER: PEOPLE PROFILE NUMBER: EXHAUST CAN EXCEED SUPPLY AIR: LEAVING HEATING COIL TEMP. (DEO.r): DRY BULB TEMPERATURE (DEG.F): COOLING COIL CFM: MISC. BTUH GAIN - SUPPLY SIDE: MISC. BTUH GAIN - RETURN SIDE: COMBINED FAN,MOTOR EFFICIENCY ( %): STATIC PRESS. ACROSS FAN (IN.WG): SUMMER SUPPLY DUCT TEMP. RISE (DEG.F): SUMMER RETURN DUCT TEMP. RISE (DEG.F): WINTER SUPPLY DUCT TEMP. DROP (DEO.F): WINTER RETURN DUCT TEMP. DROP (DEG.F): CHILLED WATER TEMP.DIFFERENCE (DEO.F): HOT WATER TEMP.DIFFERENCE (DEG.F): COOLING VENTILATION METHOD: COOLING VENTILATION VALUE: COOLING INFILTRATION METHOD: COOLING INFILTRATION VALUE: HEATING VENTILATION METHOD: HEATING VENTILATION VALUE: HEATING INFILTRATION METHOD: HEATING INFILTRATION VALUE: VENTILATION IS 100% OF SUPPLY AIR: PRETREATED OUTSIDE AIR: IGNORE PRETREATED LOAD: PRETREATED AIR SUMMER DB TEMP (DE0.F): PRETREATEp AIR SUMMER WB TEMP (DEO.F): PRETREATED AIR WINTER DB TEMP (DEG.F): DESIGN MONTH JANUARY MARCH JULY WINTER OUTDOOR OUTDOOR INDOOR DRY BULB WET BULB REL.HUM 2ND TEMP CONSTANT VOLUME SUM PEAK ZONE CFMS DRAW -THRU BOTH HEATING AND COOLING LOADS RESERVE CAPACITY 1 1 1 NO 95 550 0 0 60 4.000 0.000 0.000 0.000 0.000 0.000 0.000 2 20.000 CFM PER PERSON 0 0.000 2 20.000 CFM PER PERSON 1 1.500 AIR CHANGES PER HOUR NO NO NO 0 0 0 INDOOR DRY BULB GRAINS IN /OUTDOOR RIFF. CORRECTION 54 48 50% 75 -24.73 -39 61 49 50% 75 -32.33 -32 85 67 50% 75 5.64 -8 17 0 500 70 0,00 RECEIVED °,I7'Y OF TUMNILA JAN 1 9 2000 PERMIT CENTER * ** FULL COMMERCIAL HVAC LOADS PACE CONSULTING GROUP ZAMA * * * * * * * * * * * * * * * * * * * * * * * * ** AIR AIR HANDLER # 6 INPUT DATA: PROGRAM BY ELITE SOFTWARE DEVELOPMENT INC * ** SEATTLE, WA 9.8134 09/21/99 PAGE 6 HANDLER INPUT DATA * * * * * * * * * * * * * * * * * * * * * * * * ** AIR HANDLER DESCRIPTION: TERMINAL TYPE: METHOD FOR CV: SUPPLY PAN TYPE: CALCULATIONS PERFORMED: EXCESS SUPPLY AIR: NUMBER OF TIMES SYSTEM OCCURS: LIGHTING PROFILE NUMBER: EQUIPMENT PROFILE NUMBER: PEOPLE PROFILE NUMBER: EXHAUST CAN EXCEED SUPPLY AIR: LEAVING HEATING COIL TEMP. (DEG.F): DRY BULB TEMPERATURE (DEG.F): COOLING COIL CFM: MISC. BTUH GAIN - SUPPLY SIDE: MISC. BTUH GAIN - RETURN SIDE: COMBINED FAN,MOTOR EFFICIENCY (1): STATIC PRESS. ACROSS FAN (IN.WG): SUMMER SUPPLY DUCT TEMP. RISE (DEO.F): SUMMER RETURN DUCT TEMP. RISE (DEG.F): WINTER SUPPLY DUCT TEMP. DROP (DEO.F): WINTER RETURN DUCT TEMP. DROP (DEG.F): CHILLED WATER TEMP.DIFFERENCE (DEO.F): HOT WATER TEMP.DIFFERENCE (DEO.F): COOLING VENTILATION METHOD: COOLING VENTILATION VALUE: COOLING INFILTRATION METHOD: COOLING INFILTRATION VALUE: HEATING VENTILATION METHOD: HEATING VENTILATION VALUE: HEATING INFILTRATION METHOD: HEATING INFILTRATION VALUE: VENTILATION IS 1001 OF SUPPLY AIR: PRETREATED OUTSIDE AIR: IGNORE PRETREATED LOAD: PRETREATED AIR SUMMER DB TEMP (DEG.F): PRETREATED AIR SUMMER W8 TEMP (DEG.F): PRETREATED AIR WINTER DB TEMP (DEO.F): DESIGN MONTH JANUARY MARCH JULY WINTER OUTDOOR OUTDOOR INDOOR DRY BULB WET BULB REL.HUM 54 61 85 17 48 49 67 0 501 501 501 501 NOC ROOM VARIABLE AIR VOLUME SUM PEAK ZONE CFMS DRAW -THRU BOTH HEATING AND COOLING LOADS RESERVE CAPACITY 1 1 1 1 NO 95 550 0 0 60 3.000 0.000 0.000 0.000 0.000 0.000 0.000 2 20.000 CFM PER PERSON 0 0.000 2 20.000 CFM PER PERSON 1 1.500 AIR CHANGES PER HOUR NO NO NO 0 0 0 INDOOR GRAINS IN /OUTDOOR DRY BULB DIFF. CORRECTION 72 72 72 70 -18.42 -26.03 11.95 0.00 -36 -29 -5 RECEIVED CITY OF TUKWILA JAN 1 9 2000 PERMIT CENTER • * ** FULL COMMERCIAL HVAC LOADS PROGRAM BY ELITE SOFTWARE DEVELOPMENT INC * ** PACE CONSULTING GROUP s.c,4%)y b ey SEATTLE, WA 48134 ZAMA AG -1--- -q 09/21/99 PAGE 7 * * * * * * * * * * * * * * * ** AIR SYSTEM # 3 (WEST LOBBY) ZONE SUMMARY * * * * * * * * * * * * * * * ** ZN. ZONE - DESCRIPTION FLOOR HTG.LOSS SEN.GAIN LAT.GAIN HTG.CFM CLG.CFM NO. PEA!( TIME & MONTH AREA O.A. CFM O.A. CFM EXH. CFM CFM/SP. CFM /SF. 16 2ND LOBBY 5 PM JULY 580 65,743 36,335 2,520 2,443 1,885 240 240 0 4.21 3.25 17 2ND INT LOB 220 0 2,365 1,050 0 123 8 PM JULY 100 100 0 0.00 0.56 18 3RD INT LOB 220 0 2,365 1,050 0 123 8 PM JULY 100 100 0 0.00 0.56 19 2ND INT VEST 128 0 1,403 630 0 73 8 PM JULY 60 60 0 0.00 0.57 ZONE PEAK TOTALS TOTAL ZONES: 4 • 1 9.1 •. % •.. 1 1,148 65,743 42,468 5,250 2,443 2,204 500 500 0 2.13 1.92 • • , ■ RECEIVED CITY OF TUKWILA JAN 19 2000 PERMIT CENTER r •, ' • * ** FULL COMMERCIAL HVAC LOADS PROGRAM BY ELITE SOFTWARE DEVELOPMENT INC * ** PACE CONSULTING GROUP .ceg v & D SEATTLE, WA 911134 ZAMA By R G-1,' 09/21/99 PAGE 8 * * * * * * * * * * * * ** AIR SYSTEM # 3 (WEST LOBBY) TOTAL LOAD SUMMARY * * * * * * * * * * * * ** AYR HANDLER DESC: WEST LOBBY WITH VAV TERMINALS SUPPLY AIR FAN: DRAW -THRU WITH PROGRAM ESTIMATED HORSEPOWER OF 2.31 HP. FAN INPUT: 600 COMBINED PAN AND MOTOR EFF. WITH 4.00 IN WATER ACROSS THE PAN SENSIBLE HEAT RATIO: 0.90 THIS SYSTEM OCCURS 1 TIME(S) IN THE BUILDING AIR SYSTEM PEAK TIME: 5 PM IN JULY OUTDOOR CONDITIONS: 83 DB, 67 WS, 73.73 GRAINS INSIDE: 75 bB, SO% RH SUMMER: VENT CONTROLS OUTSIDE AIR WINTER: VENT CONTROLS OUTSIDE AIR ZONE SPACE INFILTRATION OUTSIDE AIR SUPPLY DUCT RETURN DUCT TOTAL SYSTEM SEN.LOSS: SEN.LOSS: SEN.LOSS: SEN.LOSS: SEN.LOSS: SEN.LOSS: 14,132 BTUH 51,611 STUB ( 28,521 BTUH ( 0 BTUH 0 BTUH SUPPLY AIR: 65,743 / (0.997 X 1.08 X 25) ■ WINTER VENT OUTSIDE AIR (20.5% OF SUPPLY): ZONE SPACE SEN.OAIN' 42,468 BTUH INFILTRATION SEN.OAINs 0 DTUN ( DRAW -THRU FAN SEN.OAIN: 5,846 BTUH SUPPLY DUCT SEN.OAIN: 0 BTUH TOTAL SEN.OAIN ON SUPPLY SIDE OF COIL' 754 CFM) 500 CFM) 2,443 CFM) 500 CFM) 0 CFM) SUPPLY AIR: 48,314 / (0.997 X 1.10 X 20) ■ ( 2,204 CFM) SUMMER VENT OUTSIDE AIR (22.7% OF SUPPLY): ( 500 CFM) RETURN DUCT SEN.OAIN' 0 BTUH RETURN PLENUM BEN.OAINs 0 BTUH OUTSIDE AIR SEN.OAINs 4,385 BTUH BLOW -THRU FAN 8EN.0AINs 0 BTUH TOTAL SEN.GAIN ON RETURN SIDE OF COIL: ( 500 CFM) 94,264 BTUH 48,314 BTUH 4,385 BTUH TOTAL SEN.OAIN ON AIR HANDLING SYSTEM' 52,699 BTUH ZONE SPACE LAT.OAIN: 5,250 INFILTRATION LAT.OAIN: 0 OUTSIDE AIR LAT.OAIN: 3,004 TOTAL LAT :GAIN ON AIR HANDLING SYSTEM: TOTAL SYSTEM SENSIBLE AND LATENT GAIN: BTUH BTUH ( BTUH ( TOTAL TONNAGE REQUIRED WITH OUTSIDE AIR: • .. •• • 0 CFM) 500 CFM) 8,254 BTUH 60,953 BTUH 5.08 TONS RECEIVED CITY OF TUKWILA JAN 1 9 2000 PERMIT CENTER * ** PULL COMMERCIAL HVAC LOADS PROGRAM BY ELITE SOFTWARE DEVELOPMENT INC * ** PACE CONSULTING GROUP SEATTLE, WA 9134 ZAMA 09/21/99 PAGE 9 * * * * * * * * * * ** AIR SYSTEM # 3 (WEST LOBBY) PSYCHROMETRIC ANALYSIS * * * * * * * * * * ** SYSTEM LOAD ANALYSIS LATENT GRAINS SENSIBLE TEMP CFM LEAVING COIL CONDITION DRAW -THRU PAN MISC LOAD ON SUPPLY SIDE SUPPLY AIR DUCT ZONE LOADS 61.353 5,250 3.516 5,846 0 0 42,468 55.000 2.420 0.000 0.000 17.580 ZONE CONDITION RETURN AIR DUCT RETURN AIR PLENUM MISC LOAD ON RETURN SIDE VENT AIR 500 CFM BLOW -THRU FAN 5,250 64.869 3,004 2.011 48,314 0 0 0 4,385 0 75.000 0.000 0.000 0.000 1.815 0.000 267 0 0 1,937 2,204 ENTERING COIL CONDITION 8,254 66.880 52,699 76.815 2,204 GENERAL PSYCHROMETRIC EQUATIONS USED IN ANALYSIS: PR • (BAROMETRIC TSH ■ PR X 1.10 X TLH a PR X 0.68 X GTH is PR X 4.50 X PRESSURE OF SITE / STANDARD ASHRAE PRESSURE OF 29.921) CFM X (DB.ENTERING - DB.LEAVING) CFM X (GRAINS.ENTERING - GRAINS.LEAVING) CFM X (ENTHALPY.ENTERING - ENTHALPY.LEAVING) TBH ■ 0.997 X 1.10 X 2,204 X ( 76.815 - 55.000 ) • TLH ■ 0.997 X 0.68 X 2,204 X ( 66.880 - 61.353 ) ■ SUM • GTH ■ 0.997 X 4.50 X TOTAL SYSTEM LOAD 2,204 X ( 28.900 - 22.715 ) ■ ENTERING COOLING COIL CONDITIONS: DRY BULB TEMPERATURE: 76.82 WET BULB TEMPERATURE: 63.58 RELATIVE HUMIDITY(%): 48.51 ENTHALPY: 28.90 BTU /LSM LEAVING COOLING COIL CONDITIONS: DRY BULB TEMPERATURE: 55.00 WET BULB TEMPERATURE: 54.18 RELATIVE HUMIDITY( %): 95.06 ENTHALPY: 22.72 BTU /LSM •• • 1 • 52,698 BTUH 8,253 BTUH 60,951 BTUH 61,125 BTUH 60,953 BTUH ENTERING HEATING COIL CONDITIONS: DRY BULB TEMPERATURE: 59.15 LEAVING HEATING COIL CONDITIONS: DRY BULB TEMPERATURE: 95.00 RECEIVED CITY OF TUKWILA JAN 19 2060 PERMIT CENTER * ** FULL COMMERCIAL HVAC LOADS PROGRAM BY ELITE SOFTWARE DEVELOPMENT INC * ** PACE CONSULTING GROUP smut- I) 8 y SEATTLE, WA 88134 ZAMA op ..3 7,{2 x 10 9/ 21/ 9 9 PAGE 10 * * * * * * * * * * * * * * * * ** AIR SYSTEM # 4 (2ND OFC) ZONE SUMMARY * * * * * * * * * * * * * * * * * ** zN. ZONE - DESCRIPTION FLOOR HTG.LOSS SEN.GAIN LAT.GAIN HTG.CFM CLG.CFM NO. PEAK TIME & MONTH AREA O.A. CFM O.A. CFM EXH. CFM CFM /SF. CFM /SF. 20 RECPT 5 PM JULY 21 BREAK 5 PM JULY 22 WAR ROOM 5 PM JULY 23 OFC 2 PM JANUARY 24 OFC 2 PM JANUARY 2S CONF 8 PM JULY 27 CORRIDOR 8 PM JULY 39 OFC S PM JULY ZONE PEAK TOTALS TOTAL ZONESt 8 300 9,403 9,529 1,260 349 494 360 360 0 1.16 1.65 240 9,324 11,825 1,680 347 614 160 160 0 1.4S 2.56 285 17,568 15,271 2,100 653 792 200 200 0 2.29 2.78 156 5,839 5,456 234 217 283 22 22 0 1.39 1.81 156 7,013 7,240 234 261 376 22 22 0 1.67 2.41 400 0 7,901 2,940 0 410 480 480 0 0.00 1.03 138 0 893 207 0 46 20 20 0 0.00 0.33 180 6,802 6,786 270 242 3S1 26 26 0 1.34 1.9S 1,855 58,649 64,871 8,925 2,069 3,366 1,290 1,290 0 1.12 1.81 JAN 192000 PERMIT CENTER * ** FULL COMMERCIAL HVAC LOADS PROGRAM BY ELITE SOFTWARE DEVELOPMENT INC * ** PACE CONSULTING GROUP ZAMA * * * * * * * * * * * * * * ** SEATTLE, WA 9B134 PAGE 11 * * * * * * * * * * * * * ** 09/21/99 AIR SYSTEM # 4 (2ND OFC) TOTAL LOAD SUMMARY AIR HANDLER DESC: 2ND OFC WITH CV (SUM OF PEAKS) TERMINALS SUPPLY AIR PAN: DRAW -THRU WITH PROGRAM ESTIMATED HORSEPOWER OP 3.53 HP. FAN INPUT: 609 COMBINED PAN AND MOTOR EPP. WITH 4.00 IN WATER ACROSS THE FAN SENSIBLE HEAT RATIO: 0.89 THIS SYSTEM OCCURS 1 TIME(S) IN THE BUILDING AIR SYSTEM PEAK TIME: 5 PM IN JULY OUTDOOR CONDITIONS: 83 DB, 67 WB, 73.73 GRAINS INSIDE: 75 DB, 509 RH SUMMER: VENT CONTROLS OUTSIDE AIR WINTER: VENT CONTROLS OUTSIDE AIR ZONE SPACE INFILTRATION OUTSIDE AIR SUPPLY DUCT RETURN DUCT TOTAL SYSTEM SEN.LOSS: SEN.LOSS: SEN.LOSS: SEN.LOSS: SEN.LOSS: SEN.LOSS: 22,040 BTUH 33,609 BTUH 73,584 BTUH ( 0 BTUH 0 BTUH SUPPLY AIR: 55,649 / (0.997 X'1.08 X 25) m WINTER VENT OUTSIDE AIR (62.49 OF SUPPLY): ZONE SPACE INFILTRATION DRAW -THRU FAN SUPPLY DUCT RESERVE SEN.GAIN: SEN.GAIN: SEN.GAIN: SEN.OAIN: SEN.GAIN: 61,046 BTUH 0 BTUH 8,927 ETUR 0 BTU}( 3,808 BTUH 491 CFM) 1,290 CFM) 2,068 CFM) 1,290 CFM) 0 CFM) 129,233 BTUH TOTAL SEN.GAIN ON SUPPLY SIDE OF COIL: 73,781 BTUH SUPPLY AIR: 73,781 / (0.997 X 1.10 X 20) w ( 3,365 CFM) DUMMER VENT OUTSIDE AIR (38.31 OF SUPPLY): ( 1,290 CFM) RETURN DUCT SEN.GAIN: 0 RETURN PLENUM SEN.GAINI 0 OUTSIDE AIR SEN.GAIN: 11,312 BLOW -THRU FAN SEN.GAIN: 0 TOTAL SEN.OA ±N ON RETURN SIDE OF COIL: BTUH BTUH BTU}( ( 1,290 CFM) BTUH 11,312 BTUH TOTAL SEN.GAIN ON AIR HANDLING SYSTEM: 85,093 BTUH ZONE SPACE LAT.GAIN: 8,925 INFILTRATION LAT.GAIN: 0 OUTSIDE AIR LAT.GAIN: 7,747 TOTAL LAT.GAIN ON AIR HANDLING SYSTEM: TOTAL SYSTEM SENSIBLE AND LATENT GAIN; BTUH BTUH BTUH TOTAL TONNAGE REQUIRED WITH OUTSIDE AIR: ( 0 CFM) ( 1,290 CFM) 16,672 BTUH 101,765 BTUH 8.48 TONS RECEIVED CITY OF TUK""' JAN 19 ?000 PERMIT CEN1'E.- * ** FULL COMMERCIAL HVAC LOADS PROGRAM BY ELITE SOFTWARE DEVELOPMENT INC * ** PACE CONSULTING GROUP SEATTLE, WA 98134 ZAMA 09/21/99 PAGE 12 * * * * * * * * * * * * ** AIR SYSTEM # 4 (2ND OFC) PSYCHROMETRIC ANALYSIS * * * * * * * * * * * ** SYSTEM LOAD ANALYSIS LATENT GRAINS SENSIBLE TEMP CFM LEAVING COIL CONDITION DRAW -TNRU FAN MISC LOAD ON SUPPLY SIDE SUPPLY AIR DUCT ZONE LOADS SENSIBLE RESERVE 60.956 8,925 3.914 55.000 8,927 2.420 407 0 0.000 0 0 0.000 0 61,046 16.548 2,784 3,808 1.032 174 ZONE CONDITION RETURN AIR DUCT RETURN AIR PLENUM MISC LOAD ON RETURN SIDE VENT AIR 1,290 CFM BLOW -THRU FAN 8,925 64.870 7,747 3.397 73,781 75.000 0 0.000 0 0.000 0 0.000 11,312 3.067 0 0.000 3,365 ENTERING COIL CONDITION 16,672 68.267 85,093 78.067 3,365 GENERAL PSYCHROMETRIC EQUATIONS USED IN ANALYSIS: PR ■ TSH ■ TLH ■ GTH • (BAROMETRIC PR X 1.10 X PR X 0.68 X PR X 4.50 X PRESSURE OF SITE / STANDARD ABHRAE PRESSURE OF 29.921) CFM X (DB.ENTERING - DB.LEAVING) CFM X (GRAINS.ENTERING - GRAINS.LEAVING) CFM X (ENTHALPY.ENTERINO - ENTHALPY.LEAVING) TSH • 0.997 X 1.10 X TLH • 0.997 X 0.68 X SUM • GTH ■ 0.997 X 4.50 X TOTAL SYSTEM LOAD 3,365 X ( 78.067 - 55.000 ) • 3,365 X ( 68.267 - 60.956 ) ■ 3,365 X ( 29.423 - 22.654 ) • ENTERING COOLING COIL CONDITIONS: DRY BULB TEMPERATURE: 70.07 WET BULB TEMPERATURE: 64.29 RELATIVE HUMIDITY(t): 47.49 ENTHALPY : 29.42 BTU /LBM LEAVING COOLING COIL CONDITIONS: DRY BULB TEMPERATURE: 55.00 WET BULB TEMPERATURE: 54.08 RELATIVE HUMIDITY(t): 94,47 ENTHALPY: 22,65 BTTJ /LBM w 85,094 BTUH 16,672 BTUH 101,765 BTUH 102,164 BTUH 101,765 BTUH ENTERING HEATING COIL CONDITIONS: DRY BULB TEMPERATURE: 36.95 LEAVING HEATING COIL CONDITIONS: DRY BULB TEMPERATURE: 95.00 .. (Tv OF culomi JAN 1 9 2000 PERMIT CENTER � p. * ** FULL COMMERCIAL HVAC LOADS PROGRAM BY ELITE SOFTWARE DEVELOPMENT INC * ** PACE CONSULTING GROUP _w of I & y SEATTLE, WA 28134 ZAMA AG -I ry 09/21/99 PAGE 13 * * * * * * * * * * * * * * * * ** AIR SYSTEM # 5 (2ND TEMP) ZONE SUMMARY * * * * * * * * * * * * * * * * ** ZN. ZONE - DESCRIPTION FLOOR HTG.LOSS SEN.GAIN LAT.GAIN HTG.CFM CLG.CFM NO. PEAK TIME & MONTH AREA O.A. CFM O.A. CPM EXH. CFM CPM /SP. CPM /SP. 28 OPC 2 PM MARCH 29 L OPC 10 AM JULY 30 E ENTRY 10 AM JULY 31 L OPC 1 PM JULY 32 E PERIM 10 AM JULY 33 OPEN INT 8 PM JULY 34 CORRIDOR 8 PM JULY 35 OFC 8 PM JULY 36 OFC 8 PM JULY 37 MAIN CORR 8 PM JULY 38 2ND CORE 8 PM JUtiY ZONE PEAK TOTALS TOTAL ZONES: 11 144 5,797 5,380 216 215 279 21 21 0 1.49 1.94 375 23,698 15,310 563 881 794 54 54 0 2.35 2.12 45 4,826 2,752 67 179 143 6 6 0 3.98 3.18 425 23,000 13,190 637 855 684 61 61 0 2.01 1.61 1044 41,975 40,285 1,566 1,560 2,090 149 149 0 1.49 2.00 2324 0 28,102 3,486 0 1,458 332 332 0 0.00 0.63 380 0 2,457 570 0 127 54 54 0 0.00 0.33 150 0 1,814 225 0 94 21 21 0 0.00 0.63 150 0 1,814 225 0 94 21 21 0 0.00 0.63 737 0 4,763 1,106 0 247 105 105 0 0.00 0.34 1240 0 5,581 0 0 290 0 0 0 0.00 0.23 7,014 99,296 121,448 8,661 3,690 6,300 824 824 0 0.53 0.90 RECEIVED CITY OF TUKW LA JAN 19 2000 PERMIT CENTER * ** FULL COMMERCIAL HVAC LOADS PACE CONSULTING GROUP ZAMA * * * * * * * * * * * * * ** AIR SYSTEM # 5 PROGRAM BY ELITE SOFTWARE DEVELOPMENT INC * ** SEATTLE, WA 28134 09/21/99 PAGE 14 (2ND TEMP) TOTAL LOAD SUMMARY * * * * * * * * * * * * * ** AIR HANDLER DESC: 2ND TEMP WITH CV (SUM OF PEAKS) TERMINALS SUPPLY AIR FAN: DRAW -THRU WITH PROGRAM ESTIMATED HORSEPOWER OF 6.60 HP. FAN INPUT: 60% COMBINED FAN AND MOTOR EFF. WITH 4.00 IN WATER ACROSS THE FAN SENSIBLE HEAT RATIO: 0.94 THIS SYSTEM OCCURS 1 TIME(S) IN THE BUILDING AIR SYSTEM PEAK TIME: 11 AM IN JULY OUTDOOR CONDITIONS: 76 DB, 65 WB, 75.02 GRAINS INSIDE: 75 DB, 504 RH BECAUSE OP THE DIVERSITY IN ZONE, PLENUM, AND VENT. LOADS, THE ZONE SENSIBLE PEAK TIME IN JULY AT 10 AM IS DIFFERENT FROM THE TOTAL SYS. PEAK TIME HENCE, THE AIR SYSTEM CFM WAS COMPUTED USING A ZONE SEN. LOAD OF 118,144 SUMMER: VENT CONTROLS OUTSIDE AIR WINTER: VENT CONTROLS OUTSIDE AIR ZONE SPACE INFILTRATION OUTSIDE AIR SUPPLY DUCT RETURN DUCT TOTAL SYSTEM SEN.LOSS: SEN.LOSS: SEN.LOSS: SEN.LOSS: SEN.LOSS: SEN.LOSS: 39,881 BTUH 59,415 BTUH ( 47,002 BTUH ( 0 BTUH 0 BTUH SUPPLY AIR: 99,296 / (0.997 X 1.08 X 25) to ( WINTER VENT OUTSIDE AIR (22.34 OF SUPPLY): ( ZONE SPACE SEN.GAIN: 116,534 BTUH INFILTRATION SEN.GAIN: 0 BTUH DRAW -THRU FAN SEN.GAIN: 16,711 BTUH SUPPLY DUCT SEN.GAIN: 0 BTUH RESERVE SEN.GAIN: 3,253 BTUH TOTAL SEN.GAIN ON SUPPLY SIDE OF COIL: SUPPLY AIRs138,108 / (0.997 X 1.10 X 20) • ( SUMMER VENT OUTSIDE AIR (13.14 OF SUPPLY): RETURN DUCT ' SEN.GAIN: 0 STUN RETURN PLENUM SEN.GAINI 0 BTUH OUTSIDE AIR SEN.GAIN: 903 BTUH ( BLOW -THRU FAN SEN.GAIN: 0 BTUH TOTAL SEN.GAIN ON RETURN SIDE OF COIL: TOTAL SEt3.GAIN ON AIR HANDLING SYSTEM: ZONE SPACE LAT.GAIN: 8,661 BTUH INFILTRATION LAT.GAIN: 0 BTUH OUTSIDE AIR LAT.GAIN: 5,666 BTUH ( TOTAL LAT.GAIN ON AIR HANDLING SYSTEM: TOTAL SYSTEM SENSIBLE AND LATENT GAIN: TOTAL TONNAGE REQUIRED WITH OUTSIDE AIR: 868 CFM) 824 CFM) 3,690 CFM) 824 CFM) 0 CFM) 6,299 CFM) 824 CFM) 824 CFM) 0 CFM) 824 CFM) 146,298 BTUH 136,498 STUN 903 BTUH 137,401 STUN 14,327 BTUH 151,728 BTUH 12.64 TONS RECEIVED CITY OF TUKWILA JAN 19 2000 PERMIT CENTER * ** FULL COMMERCIAL HVAC PACE CONSULTING GROUP ZAMA * * * * * * * * * * * ** AIR SYSTEM LOADS PROGRAM BY ELITE SOFTWARE DEVELOPMENT INC * ** SEATTLE, WA 9,8134 09/21/99 PAGE 15 # 5 (2ND TEMP) PSYCHROMETRIC ANALYSIS * * * * * * * * * * * ** SYSTEM LOAD ANALYSIS LATENT GRAINS SENSIBLE TEMP CFM LEAVING COIL CONDITION DRAW -THRU FAN MISC LOAD ON SUPPLY SIDE SUPPLY AIR DUCT ZONE LOADS SENSIBLE RESERVE 62.839 55.000 16,711 2.420 0 0.000 0 0.000 8,661 2.029 118,144 17.109 3,253 0.471 762 0 0 5,389 148 ZONE CONDITION RETURN AIR DUCT RETURN AIR PLENUM MISC LOAD ON RETURN SIDE VENT AIR 824 CFM BLOW -THRU FAN 8,661 64.868 5,666 1.328 138,108 75.000 0 0.000 0 0.000 0 0.000 903 0.131 0 0.000 6,299 ENTERING COIL CONDITION 14,327 66.195 139,011 75.131 6,299 GENERAL PSYCHROMETRIC EQUATIONS USED IN ANALYSIS: PR - (BAROMETRIC TSH - PR X 1.10 X TLH - PR X 0.68 X OTH - PR X 4.50 X PRESSURE OF SITE / STANDARD ASHRAE PRESSURE OF 29.921) CFM X (DB.ENTERING - DB.LEAVXNG) CFM X (ORAINS.ENTERINO - ORAINB.LEAVINO) CFM X (ENTHALPY.ENTERING - ENTHALPY.LEAVINO) TBH ■ 0.997 X 1.10 X 6,299 X ( 75.131 - 55.000 ) ■ TLH - 0.997 X 0.68 X 6,299 X ( 66.195 - 62.839 ) - SUM - GTH ■ 0.997 X 4.50 X TOTAL SYSTEM LOAD 6,299 X ( 28.382 - 22.946 ) - ENTERING COOLING COIL CONDITIONS: DRY BULB TEMPERATURE: WET BULB TEMPERATURE: RELATIVE HUMIDITY( %): ENTHALPY:_ 28. 75.13 62.86 50.79 38 BTU /LBM LEAVING COOLING COIL CONDITIONS: DRY BULB TEMPERATURE; 55,00 WET BULB TEMPERATURE; 54.56 RELATIVE HUMIDITY(%); 97.34 ENTHALPY; 22.95 BTU /LBM ■ 139,011 BTUH 14,329 BTUH 153,340 BTUR 153,577 BTUH 151,728 BTUH ENTERING HEATING COIL CONDITIONS: DRY BULB TEMPERATURE: 58.16 LEAVING HEATING COIL CONDITIONS; DRY BULB TEMPERATURE; 95.00 RECEIVED CITY OF TUKWILA JAN 19 2000 PERMIT CENTER *** PULL COMMERCIAL HVAC LOADS PROGRAM BY ELITE SOFTWARE DEVELOPMENT INC *** PACE .CONSULT/NO GROUP g?lit0s, ay . SEATTLE, WA $8134 ZAMA agm.11 -4, 09/21/99 PAGE 16 AIR SYSTEM # 6 (NOC ROOM) ZONE SUMMARY ****************** ZN. ZONE - DESCRIPTION FLOOR HTG.LOSS SEN.GAIN LAT.GAIN HTG.CFM CLG.CPM NO PEAK TIME & MONTH AREA O.A. CFM O.A. CFM EXH. CFM CFM/SF. CPM/SF. 26 NOC 340 0 43,973 510 0 2,642 8 PM JULY 49 49 0 0.00 7.77 ZONE PEAK TOTALS 340 0 43,973 510 0 2,642 TOTAL ZONES: 1 49 49 0 0.00 7.77 • . . , • JAN 1 9 MO PERMIT CENTER • • 0 F5 ,.. * ** FULL COMMERCIAL HVAC LOADS PACE CONSULTING GROUP ZAMA * * * * * * * * * * * * * ** AIR SYSTEM # 6 PROGRAM BY ELITE SOFTWARE DEVELOPMENT INC * ** SEATTLE, WA 90134. 09/21/99 PAGE 17 (NOC ROOM) TOTAL LOAD SUMMARY * * * * * * * * * * * * * ** AIR HANDLER DESC: NOC ROOM WITH VAV TERMINALS SUPPLY AIR FAN: DRAW -THRU WITH PROGRAM ESTIMATED HORSEPOWER OF 2.08 HP. FAN INPUT: 60% COMBINED FAN AND MOTOR EP'F. WITH 3.00 IN WATER ACROSS THE FAN SENSIBLE HEAT RATIO: 0.99 THIS SYSTEM OCCURS 1 TIME(S) IN THE BUILDING AIR SYSTEM PEAK TIME: 5 PM IN JULY OUTDOOR CONDITIONS: 83 DB, 67 WB, 73,73 GRAINS INSIDE: 72 DB, 50t RH BECAUSE OF THE DIVERSITY IN ZONE, PLENUM, AND VENT. LOADS, THE ZONE SENSIBLE PEAK TIME IN JULY AT 8 PM I9 DIFFERENT FROM THE TOTAL SYS. PEAK TIME HENCE, THE AIR SYSTEM CFM WAS COMPUTED USING A ZONE SEN. LOAD OP 43,973 SUMMER: VENT CONTROLS OUTSIDE AIR ZONE SPACE INFILTRATION OUTSIDE AIR SUPPLY DUCT RETURN DUCT TOTAL SYSTEM SEN.LOSS: SEN.LOSS: SEN.LOSS: SEN.LOSS: SEN.LOSS: SEN.LOSS: WINTER: VENT CONTROLS OUTSIDE AIR 0 BTUH 0 BTUH 2,795 BTUH ( 0 BTUN 0 BTUH SUPPLY AIR: 0 / (0.997 X 1.08 X 0) ■ WINTER VENT OUTSIDE AIR (O.00% OF SUPPLY): ZONE SPACE SEN.GAIN: 43,973 BTUH INFILTRATION SEN.GAIN: 0 BTUH DRAW -THRU FAN SEN.GAIN: 5,256 BTUH SUPPLY DUCT SEN.GAIN: 0 BTUH TOTAL SEN.GAIN ON SUPPLY SIDE OF COIL: SUPPLY AIR: 49,229 / (0.997 X 1.10 X 17) • SUMMER VENT OUTSIDE AIR (1.85% OF SUPPLY): RETURN DUCT SEN.GAIN: 0 BTUH RETURN PLENUM SEN.GAIN: 0 STUN OUTSIDE AIR SEN.GAIN: 591 BTUH BLOW -THRU FAN SEN.GAIN: 0 BTUR TOTAL SEN.GAIN ON RETURN SIDE OF COIL: TOTAL SEN:OAIN ON AIR HANDLING SYSTEM: ZONE SPACE LAT.GAIN: 510 BTUH INFILTRATION LAT.GAIN: 0 BTUH OUTSIDE AIR LAT.GAIN: 504 BTUH TOTAL LAT.GAIN ON AIR HANDLING SYSTEM: TOTAL SYSTEM SENSIBLE AND LATENT GAIN: TOTAL TONNAGE REQUIRED WITH OUTSIDE AIR; ( ( ( ( ( 0 CFM) 49 CFM) 0 CFM) 49 CFM) 0 CFM) 2,642 CFM) 49 CFM) 49 CFM) 0 CFM) 49 CFM) 2,795 BTUH 49,229 BTUH 591 BTUH 49,820 BTUH 1,014 BTUH 50,834 BTUH 4.24 TONS RECEIVED CITY OF TUKWILA JAN 19 2000 ..� :... PERMIT CENTER * ** PULL COMMERCIAL HVAC PACE CONSULTING GROUP ZAMA * * * * * * * * * * * ** AIR SYSTEM LOADS PROGRAM BY ELITE SOFTWARE DEVELOPMENT INC * ** SEATTLE, WA 98134 09/21/99 PAGE 18 # 6 (NOC ROOM) PSYCHROMETRIC ANALYSIS * * * * * * * * * * * ** SYSTEM LOAD ANALYSIS LATENT GRAINS SENSIBLE TEMP CFM LEAVING COIL CONDITION DRAW -THRU FAN MISC LOAD ON SUPPLY SIDE SUPPLY AIR DUCT ZONE LOADS 58.243 510 0.285 5,256 0 0 43,973 55.000 1.815 0.000 0.000 15.185 ZONE CONDITION RETURN AIR DUCT RETURN AIR PLENUM MISC LOAD ON RETURN SIDE VENT AIR 49 CFM BLOW -THRU FAN 510 58.528 SO4 0.282 49,229 0 0 0 591 0 72.000 0.000 0.000 0.000 0.204 0.000 282 0 0 2,360 2,642 ENTERING COIL CONDITION 1,014 58.810 49,820 72.204 2,642 GENERAL PSYCHROMETRIC EQUATIONS USED IN ANALYSIS: PR - T8H - TLH - OTH - (BAROMETRIC PR X 1.10 X PR X 0.68 X PR X 4.50 X PRESSURE OF SITE / STANDARD ASHRAE PRESSURE OF 29.921) CFM X (DB.ENTERING - DB.LEEAVING) CFM X (ORAINS.ENTERING - GRAINS.LEAVINO) CFM X (ENTHALPY.ENTERING - ENTHALPY.LEAVING) TBH - 0.997 X 1.10 X TLH - 0.997 X 0.68 X SUM ■ OTH - 0.997 X 4.50 X TOTAL SYSTEM LOAD 2,642 X ( 72.204 - 55.000 ) - 2,642 X ( 58.810 - 58.243 ) - 2,642 X ( 26.514 - 22.233 ) • ENTERING COOLING COIL CONDITIONS; DRY BULB TEMPERATURE; 72.20 WET BULB TEMPERATURE: 60.20 RELATIVE HUMIDITY(%): 49.87 ENTHALPY; 26.51 BTU /LBM LEAVING *COOLING COIL CONDITIONS: DRY BULB TEMPERATURE; 55.00 WET BULB TEMPERATURE: 53,38 RELATIVE HUMIDITY( %): 90.31 ENTHALPY; 22.23 BTU /LAM 49,819 BTUH 1,015 BTUH 50,834 BTUH 50,715 BTUH 50,834 BTUH ENTERING HEATING COIL CONDITIONS; DRY BULB TEMPERATURE: 70.00 LEAVING HEATING COIL CONDITIONS: DRY BULB TEMPERATURE: 70.00 CITYOF�TU1KCWILA JAN 19 2000 PERMIT CENTER * ** FULL COMMERCIAL HVAC LOADS PROGRAM BY ELITE SOFTWARE DEVELOPMENT INC * ** PACE CONSULTING GROUP SEATTLE, WA 98134 ZAMA 09/21/99 PAGE 19 * * * * * * * * * * * * * * * * * * * * * * * ** BUILDING ENVELOPE REPORT * * * * * * * * * * * * * * * * * * * * * * * ** ENVELOPE REPORT USING WINTER U- FACTORS: MATERIAL GROSS GLASS NET -U- AREA x AVERAGE TYPES AREA AREA AREA FACTOR UFACTOR UPACTOR ROOF 1 225.0 0.0 225.0 0.038 8.550 0.038 WALL 1 4459.0 1564.0 2895.0 0.140 405.300 0.140 GLASS 1 1331.0 N/A 1331.0 0.500 665.500 0.500 2 233.0 N/A 233.0 0.500 116.500 0.500 TOT.GLAS 1564.0 N/A 1564.0 N/A 782.000 0.500 TOTALS 4684.0 N/A 1195.850 0.255 WALL WALL GLASS WALL NET W.AVG GLASS AVG GLASS AVa DIRECTION AREA AREA AREA U -FAC U- FACTOR SHD.COEFF N 0.0 0.0 . 0.0 0.000 0.000 0.000 NE 0.0 0.0 0.0 0.000 0.000 0.000 8 1755.0 611.0 1144.0 0.140 0.500 0.450 88 0.0 0.0 0.0 0.000 0.000 0.000 8 1131.0 369.0 762.0 0.140 0.500 0.450 8W 0.0 0.0 0.0 0.000 0.000 0.000 W 1573.0 584.0 989.0 0.140 0.500 0.450 NW 0.0 0.0 0.0 0.000 0.000 0.000 TOTALS 4459.0 1564.0 2895.0 0.140 0.500 0.450 RECEIVED CITY OF TUKwio JAN 19 2000 PERMIT CENTEF: * ** FULL COMMERCIAL HVAC LOADS PROGRAM BY ELITE SOFTWARE DEVELOPMENT INC * ** PACE CONSULTING GROUP SEATTLE, WA 88134 ZAMA 09/21/99 PAGE 20 * * * * * * * * * * * * * * * * * * * * * * ** TOTAL BUILDING LOAD SUMMARY * * * * * * * * * * * * * * * * * * * * * ** BUILDING PEAKS IN JULY AT 4 PM BLDG. LOAD AREA DESCRIPTIONS QUAN SEN. %TOT LAT. LOSS LOSS GAIN + SEN. GAIN TOTAL %TOT GAIN GAIN ROOF WALL GLASS 225 2,895 1,564 544 0.15 25,777 6.92 49,738 13.35 0 424 0 16,887 0 69,573 424 0.12 16,887 4.81 69,573 19.81 SKIN LOADS 4,684 76,059 20.41 0 86,884 86,884 24.74 LIGHTING EQUIPMENT PEOPLE PARTITION VENT 2,663 INFL 2,113 DRAW -THRU FAN BLOW -THRU FAN SUPPLY DUCT RETURN DUCT RESERVE CAPACITY 12,429 21,502 110 0 2,663 0 0 0 0 0 151,902 144,635 0 0 0 0 0 0.00 0.00 0.00 0.00 40.77 38.82 0.00 0.00 0.00 0.00 0.00 0 0 23,346 0 13,090 0 0 0 0 0 0 46,622 80,659 30, 574 0 26,272 0 36, 740 0 0 0 7,061 46,622 13.27 80,659 22.96 53,920 15.35 0 0.00 39,362 11.21 0 0.00 36,740 10.46 0 0.00 0 0.00 0 0.00 7,061 2.01 BUILDING TOTALS 372,596 100.00 36,436 314,812 351,248 100.00 BUILDING SUMMARY LOAD DESCRIPTIONS SEN. %TOT LOSS LOSS LAT. GAIN + SEN. GAIN ■ TOTAL %TOT GAIN GAIN VENTILATION INFILTRATION ZONE LOADS ' PLENUM LOADS FAN & DUCT LOADS 151,902 40.77 144,635 38.82 76,059 20.41 0 0.00 0 0,00 13,090 0 23,346 0 0 26,272 0 251,800 0 36,740 39,362 0 275,146 0 36,740 11.21 0.00 78.33 0.00 10.46 BUILDING TOTALS 372,596 100.00 36,436 314,812 351,248 100.00 TOTAL BUILDING SUPPLY AIR (BASED ON A 19 TD): TOTAL BUILDING VENT AIR (18.341 OF SUPPLY): TOTAL CONDITIONED AIR SPACE: SUPPLY AIR CFM / SQ.FT, OF CONDITIONED SPACE: SQ.FT OF CONDITIONED AIR SPACE PER TON: TONNAGE PER SQ.FT OF CONDITIONED AIR SPACE: TOTAL HEATING REQUIRED WITH OUTSIDE AIR: TOTAL TONNAGE REQUIRED WITH OUTSIDE AIR: 14,510 2,663 10,357 1.4010 353.8355 0.0028 CFM CFM SQ.FT CFM /SQ.FT SQ.FT /TON TONS / SQ.FT 372.60 MEN 29.27 TONS RECEIVED CITY QF TUKWH. JAN 1 9 2000 PERMIT CEN1 Ef 1 OR TRAIPIE Prepared For: Contractor: McKinstry Company Sold To: McKinstry Company P.O. Box 24587 5005 Third Ave S. (98134) Seattle, WA 98124 Submittal Date: January 03, 2000 The Vane Company A Division of American Standard Inc. Job Name: Zama Networks The Trane Company is pleased to provide the enclosed submittal for your review. Products Included in this Submittal Package: Qty Description 1 Packaged Heat Pump Units (Dedicated) Seattle - Art Smith 2021 162nd Avenue NE REDMOND, WA 98062 Phone: 426.643 -4310 Fax: 425843.4314 The attached information describes the equipment ws propose to furnish for this protect, end is submitted for your approval, M2.000 Ol'4 C:IW1NQOW51TEMAZAMAAC 1.QOC RECEIVED c 'ry OF TUKWILA JAN 19 2000 PERMIT CENTER Trans Submittal Papa 1 of 11 ;�,�.. Zama Networks January 03, 2000 • Table of Contents Packaged Heat Pump Units (Dedicated) (Item Al) Tag Data 3 Product Data 3 Mechanical Specifications 4 Unit Dimensions 8 Weight, Clearance & Rigging Diagram 8 Accessory 9 Field Wiring 11 CITY OF TUKWU r . JAN 19 2000 ti PERMIT CENTER FLD as Furnished by Trene / Installed by Others • Zama Networks Tag Data - Packaged Heat Pump lIts (Dedicated) • Item Tag(s) Qty Description Al AC -1 1 20 Ton Packaged Unitary Heat Pump Product Data Item: Al Qty: 1 Tag(s): AC -1 Horizontal Configuration 20 ton - Normal Cooling Capacity 460 Volts 60 Hertz Three Phase Economizer (FId) Programmable Sensor with Night Setback and System Function Lights (FId) 54kW @240,480,600v Electric Heaters (berate to Unit Voltage) (FId) January 03, 2000 Model Number WCH2408400 PERMIT CENTER FLO • Furnished by Trans /Installed by Others Trans Submittal Pape 3 0111 Zama Networks January 03, 2000 Mechanical Specifications - Par led Heat Pump Units (Dedicated) Item(s): Al Qty: 1 Tag(s): AC- General - Horizontal Unit The unit is dedicated horizontal airflow. The operating range is between 115 deg F (46.1 deg CJ and 0 deg F ( -17.8 deg C] in cooling as standard from the factory. Cooling performance is rated in accordance with ARI testing procedures. All units are factory assembled, internally wired, fully charged with R -22 and 100 percent run tested to check cooling operation, fan and blower rotation and control sequence, before leaving the factory, Wiring internal to the unit is colored and numbered for simplified identification, Units are UL listed and labeled, classified in accordance to UL 1995 /CAN /CSA No. 236 -M90 for Heat Pumps. Canadian units shall be CSA Certified. Casing Unit casing is constructed of zinc coated, heavy gauge, galvanized steel. All components are mounted In a weather resistant steel cabinet with a painted exterior, Unit's surface shall be tested 600 hours in a salt spray test In compliance with ASTM B117. Cabinet construction allows for all maintenance on one side of the unit, Service panels have lifting handles and are removed and reinstalled by removing one to three screws while providing a water and air tight seal, The Indoor air section completely insulated with fire resistant, permanent, odorless glass fiber material. The base of the unit has provisions for forklift and crane lifting, Compressors for 15.20 Ton Units The unit has two direct drive hermetic, reciprocating type compressors with a centrifugal oil pump providing positive lubrication to moving parts. Motor is suction gas cooled and has a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Crankcase heater, internal temperature and current - sensitive motor overloads are included for maximum protection. The compressors have internal spring isolation and sound muffling to minimize vibration transmission and noise. External high pressure cutout and low pressure switches are standard. Controls for 10 -20 Ton Units Unit is completely factory wired with necessary controls and terminal block for power wiring. Units shall provide an external location for mounting fused disconnect device, Micro- processor controls are provided for all 24 volt control functions. The resident control algorithms will make all heating, cooling and /or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point and provides better building comfort, A centralized micro- processor will provide anti -short cycle timing and time delay relay between compressors for a higher level of machine protection. Refrigerant Circuits for 10-20 Ton Units The two Independent refrigerant circuits have short orifice expansion devices, service pressure ports and refrigerant line filter driers as standard, An area Is provided for replacement suction line driers, Evaporator and Condenser Coils for 10-20 Ton Units Internally finned 3/8" (9,53 mm) copper tubes mechanically bonded to configured aluminum plate fin are standard. Coils are leak tested at the factory to ensure the pressure integrity, The evaporator and condenser coils are leak tested to 200 psig [1379 kPa] and pressure tested to 450 psig [3102.8 kPa). The.evaporator coil is intermingled. `"� °" "Iv " JAN 1 9 2000 PERMIT CENTER Indoor Fan and Motor for 10 -20 Ton Units Unit has a FC, centrifugal fan with a belt driven, adjustable sheave, thermally protected motor. The unit has an adjustable idler arm assembly for quick adjustment of fan belts and motor sheaves, Outdoor Fans for 12.5-20 Ton Units The outdoor fans are direct - drive, statically and dynamically balanced, draw through in the vertical discharge position. The fan motors are permanently lubricated and have built in thermal overload protection. Filters for 10.20 Ton Units 2" (50.8 mmJ, throwaway filters are standard. Defrost Control for 10-20 Ton Units The unit's time initiated, temperature terminated defrost system ships with a setting of 70 with a choice of 60 or 90 minute cycle, Timed override limits defrost cycle to 10 minutes. Horizontal Economizer for Field Installation This accessory will be field Installed. The assembly Includes- - fully modulating 0-100 percent motor and dampers, minimum position setting, preset linkage, wiring harness with plug and fixed dry bulb control, 480v/3 Phase Electric Heater Electric heat modules will be available for field installation within basic unit, Electric heater elements will be constructed of heavy -duty nickel chromium elements Internally wye connected for 480 volt. Staging will be achieved through the unitary control processor (UCP). Each heater package will have automatically reset high limit control operating through heating element contactors. All heaters will be individually fused from factory, where required, and meet all NEC and CEC requirements when properly installed. Power FLD = Furnished by Trano / Installed by Others Trans Submittal Page 4 of 11 Zama Networks January 03, 2000 assemblies will provide single- . point connection. Electric heat modules will be UL listed or CSA certified. Programmable Zone Sensor This electronic zone sensor provides programmable night setback in addition to normal operating modes, The 7- day constant volume sensor has four time periods available per day to program, Each period can be programmed for Occupied and Unoccupied status. Two temperature settings ( Heat/Cool) can be programmed for both the Occupied and Unoccupied periods. The sensor does not require a battery, rather if a power interruption occurs the program is retained in Permanent Memory. If the power interruption is longer than 2 hours, the clock and day may need resetting, but the program will stay Intact. Programming features Include: "Intelligent Copy ", saves steps during programming by automatically copying weekday and weekend programs and schedules. "Intelligent Temperature Recovery",automatically FLO computes when to turn the unit on so that the comfort temperature is reached by the start of the occupied period, resulting In energy savings. Adjustable Check Filter Interval, an interval can be set based on fan run time to prompt user to check Filter by displaying a "check filter" indication in the display. Keyboard Lockout, allows the keyboard to be disabled in order to avoid unauthorized changes. The key pad features four system switch settings, two fan switch settings, six programming buttons, and two temperature slide settings to select unit operation, The digital liquid crystal display (LCD) shows zone temperature, heat/cool setpolnts, day of week, time and operational modes symbols, Under normal operating conditions the current zone temperature Is displayed. Program selection, override, and all other functions are executed by keypad entry The zone sensor has nine dip switches on the subbase that can be used to enable and disable the following features: Option Switches: Morning Warm -up Override during unoccupied period Supply air tempering Remote zone temperature sensor hour time indication Smart Fan - allows automatic fan operation during unoccupied periods regardless of fan switch setting. Computed recovery Connection to the zone sensor can be made with standard thermostat wire, consult installing literature for details, An optional remote zone sensor can be added as an accessory. The zone sensor terminal board has the ability to utilize an auxiliary relay rated for 1.25 amps at 30 vac. This relay will be energized only in the Unoccupied mode and has either normally open or closed contacts. CITY RECEIVED JAN 1 9 2000 PERMIT CENTEk Furnished by Trane / installed by Others Trane Submittal Page 5 of 11 Zama Networks Unit Dimensions - Packaged He lump Units (Dedicated) Item: Al Qty: 1 Tag(s): AC -1 January 03, 2000 Service Gauge Pmt Access r 7/8" 122,im nit Ofa. Hole (Unit Con1ro1 Wwes) 8 3l4" 33 l4 2'l81mm) 6lecukal Conn. Single Point Power When Supplemental Heat Is Installed FRONT VIEW 3' (78.2mm)O a. Unlltt Power wires 2 3/4" 121 3l4 "— 20112" 24 P27 Gil Door mesa IS" 40 l0" 5vpph opening b 310' Return opening O ri Conn otion 1'120.4 mmi NPT TOP VIEW BACK VIEW RECEIVED CITY OF TUV""1 a JAN 19 2000 PERMIT CENTER FLO • Furnished by Trane / Installed by Others Trani Submittal Page 6 of 11 4'J • Zama Networks Unit Dimensions - Packaged He 'pump Units (Dedicated) • Item: Al Qty: 1 Tag(s): AC -1 ELECTRICAL / GENERAL DATA January 03, 2000 NOTES: 1. Maadmum (HACR per NEC) Circuit Croaker Axing N for Installations In the United 8Istes only, 2. Refrigerant charge Is an apprardmate value, For a more precise value, see unit nameplate and service Instructions. 3. Value Includes Electric Heater Accessory, FLD a Furnished by Trento / Installed by Others Trane Submittal RECEIVED CITY OF TUKWIL JAN 19 2000 PERMIT CENTEk Page 7 of 11 Tons 0 20 ( 70.4 kW) Unit Operating Voltage Range 414 — 50e Unit Primary Voltage 480 Unit Secondary Voltage Unit Hertz 90 Field installed Unit Phase 3 Oversized Motor Minimum Circuit Ampacity (3) 133.0 Maximum Fuse Size (3) 150 Maximum (HACR) Circuit Breaker (1) (3) 150 COMPRESSOR Circuit 01 Circuit p2 Number 1 1 Horsepower 10.0 -- ( 7,48 kW) 10.0 — ( 7.49 kWJ Phase 3 3 Compressor Rated Load Amps 19.0 10.0 Locked Rotor Amps 09 e9 INDOOR MOTOR Field Oversized Moor Number 1 Horsepower 8.0 -- ( 173 kW) •— ( kW) Motor Speed (RPM) 3460 Phase 3 Indoor Motor Full Load Amps 7.9 Locked Rotor Amps 83.e OUTDOOR MOTOR .. Number 2 Horsepower t.o — ( 0:78 kW) Motor speed (RPM) 1126 Phase 1 Outdoor Motor Pull Load Amps 2,0 Locked Rotor Amps 0,3 POWER EXHAUST ACCESSORY Horsepower Field owe Exhaust Power Exhaust — ( kWJ Motor Speed (RPM) Phase Power Exhaust Full Load Amps Locked Rotor Amps •OM FILTERS • Type Throwaway Furnished Yes Number 8 Recommended Cu 20464 (806.0435,O4101,emm) REFRIGERANT Type R.22 Factory Charge (circuit 01) (2) 10.0 Factory charge (circuit 02) 19.0 NOTES: 1. Maadmum (HACR per NEC) Circuit Croaker Axing N for Installations In the United 8Istes only, 2. Refrigerant charge Is an apprardmate value, For a more precise value, see unit nameplate and service Instructions. 3. Value Includes Electric Heater Accessory, FLD a Furnished by Trento / Installed by Others Trane Submittal RECEIVED CITY OF TUKWIL JAN 19 2000 PERMIT CENTEk Page 7 of 11 Zama Networks Weight, Clearance & Rigging DI '•am - Packaged Heat Pump Units (Ded' 'ed) Item: Al Qty: 1 Tag(s): AC -1 RIGGING AND CENTER OF GRAVITY VIEW January 03,2000 MAXIMUM WVIOHT$ lb CORNER WEIOHT0 Ib IHIPPINO NIT A 11 I C D 2315 1010 040 407 [ 340 435 NOTE: 1. Comet wslphls are Oven to In ormaWwh any, L Comu A la who. Wang MHO I, shown, Coma 11, 0, and 0 are In a docJw4w dr.abon: CLEARANCE VIEW REcEry @G CITY OF T1 'u t h.■ JAN 1 9 7000 PERMIT CENTER Page 8 of 11 Furnished by Trene /Installed by Others Trane Submittal Zama Networks Accessory - Packaged Heat Pur 'Units (Dedicated) Unit Drawing for Accessories Item: Al Qty: 1 Tag(s): AC-1 January 03, 2000 • ;•• ",•• i a I 11 It S 1 III 1 i1 1 — ID 11 RECEIVED CITY OF T(JKWI$ JAN 1 9 2000 PERMIT CENTEI, FLD ow Furnished by Trans / Installed by Others Trane Submlffal Page 9 of 11 Zama Networks January 03, 2000 Accessory - Packaged Heat Pur Units (Dedicated) J BaysensOl9 - Programmable Setssor with Night Setback !tern: Al Qty: 1 Tag(s): AC -1 3, BAYSEN019 PROGRAMMABLE NIGHT SETBACK SENSOR rI ON1 MEW (1111EN 00011111 0001) 4"•+a01E74NO /011 71111MNAL WPM .o- 1,102 ,1i+ wiersebnacTar 1,1114 . 3121 .,. 4443 11ACK GOYIM 1,147 4.143 RECEIVED CITY OF TUKWP JAN 19 2000 FLO Furnished by Trans / Installed by Others PERMIT CENTEF Trans Submittal Page 10 of 11 bee! ?00 ►11811014 roirartr4wnt nm NwNMMONIM 12:0 2 "'may-. MN r N.Y. &NW war rr✓ we ♦ 18 + j ( • . J lino Mt ,11,W rrw�M �„� ti I = 1 '= coo too we to* rI ON1 MEW (1111EN 00011111 0001) 4"•+a01E74NO /011 71111MNAL WPM .o- 1,102 ,1i+ wiersebnacTar 1,1114 . 3121 .,. 4443 11ACK GOYIM 1,147 4.143 RECEIVED CITY OF TUKWP JAN 19 2000 FLO Furnished by Trans / Installed by Others PERMIT CENTEF Trans Submittal Page 10 of 11 Zama Networks Field Wiring • Packaged Heat Pt--1 Units (Dedicated) Item: Al Qty: 1 Tag(s): AC -1 Lie 11 .1 1 —12 — 14 40 ✓ • ..✓1 — 0 January 03, 2000 PR .WYA0U1 vrtI11 0404CAtop uditsl CCCI.oitoAMOeCUfh00 Fg00RAu3 t;0 1M" . 3Et NOtt tAr3EN.001011 204 OEN30$1 1111111 t 0 t 40 11 12 11 1 1 1 1 1 1 1 111 MAY Mil El (11-! JONI 011NOOR 1NIrW TADLU NOTU: 1. Al wiring and devices shown dashed to be supplied and Installed by the customer in eccordanw with national end local electrical codes. Z, Low voltage control wiring must not be run In conduit w1th power wiring. 3. Refer to sone sensor Installers guide for zone sensor switch configuration. ZZ OAUOU ZO OAUOa 10 OAUOU to OAUOU 14 OAUOe 1000' 3000' 4000' 7200' 11100• RECEIVED CITY OF TUKA1t4 JAN 19 2000 PERMIT CENTEr. FLO a Furnished by Two /Installed by Others Trans Submittal Page 11 Of 11 NILSON•IOURDAGLS Consulting Engineers a t)ivlslon otroggemeytr Design Croup, Ina. 512 Sixth Street South, Suite 202 • Kirkland, WA 98033 (423) 827.5995 527.5995 • FAX (425) 828•4890 ' oi•' ame 24 MA- . r . a e y Date �/„ /a. / n No, 16,064- Chet�Cec� by Date Sheet No. I/ )i eau pt on C,G UN ntp. FAKI IAL. t• rt.AN t3-1Ca c� I col 6 "4 "§ January 14, 2000 Mr, Duane Griffin Building Inspector, City of Tukwila 6300 Southcenter Boulevard Tukwila, WA 98188 Dear Mr, Griffin: RE: Intergatc West Corporate Park Building C Rooftop Units Tukwila, WA The roof, and the entire structure, has been designed to adequately support the roof mounted air handling units, The gravity and lateral loads (seismic zone 3) have been reviewed in accordance with the 1997 edition of the Uniform Building Code, Reference: Mechanical drawings by Parrott Mechanical, Inc., sheets M0,0 and M1.7, dated December 22, 1999. Roof mounted units include air handling units AHU -3 (6000 lbs.) and AHU-4 (6000 lbs.) Please call if you have fttrther questions. Sincerely, Robert Bour. . • es President Nelson•Bourdages A Division of Poggemoyer Design Group, Inc. CO Haynes Lund ,S1(41144% �oFWAS1ik qq4 RHCEM CITY OF TUKWII t JAN 19 2000 P iiMT UNTO Cou,r ,... .. .., .., wove '' � •' 1 `, �ON1ii oCTc NR'4 NELSAN•BOURDAGIS a Division of Poggemeyer Design Group, Inc. 51? $iyth,Street South, Suite 202 • (cirklnd. Wq,g$033 (425) 827.5995 • Fax (425) 828.4850 January 11, 2000 FILE CO!L.. ..,,,, Mr. Duane Grif n Building inspector, City of Tukwila 6300 Southcenter Boulevard Tukwila, WA 98188 Dear Mr, Griffin: RE: Intergate West Corporate Park Building C Rooftop Units — Zama Networks Tenant Improvement Tukwila, WA The roof mounted air handling units are smaller than what was originally programmed for the core and shell design , therefore the roof and building structure will adequately support them. The gravity and lateral loads (seismic zone 3) have been reviewed in accordance with the 1997 edition of the Uniform Building Code, Please reference mechanical drawings M3.5 and M8.1 by McKinstry, dated December 15, 1999. Equipment list includes ono HVU•1(1700 Ibs,) and one AC -1 Heat Pump (2500 Ibs.). Please call if you have fiuther questions. Sincerely, 4(1)1' bert Bourdages, P,E, P . sident • Nelson-Bourdages A Division of Poggemeyer Design Group, Inc. Enclosure: partial roof plan CC: Haynes Lund eocg4�L. o4, MzcrjjOl'I NELSON- BOURDAGES a Division of Poggemeyer Design Group, Inc. 512 Siicth Street South, Suite 202 • KirkiVi,.WA 98033 (425) 827.5995 • Fax (425) 828.4850 RECEIVED CITY OF TUKWILA JAN 19 2000 PERMIT CENTER • , r - rat January 11, 2000 Mr. Duane Griffin Building Inspector, City of Tukwila 6300 Southcenter Boulevard Tukwila, WA 98188 Dear Mr, Griffin: RE: Intergate West Corporate Park Building C Rooftop Units — Zama Networks Tenant improvement Tukwila, WA The roof mounted air handling units are smaller than what was originally programmed for the core and shell design , therefbre the roof and building structure will adequately support them. The gravity and lateral loads (seismic zone 3) have been reviewed in accordance with the 1997 edition of the Uniform Building Code, Please reference mechanical drawings M3.5 and M8.1 by McKinstry, dated December 15, 1999. Equipment list includes one HVU -1 (1700 Ibs,) and one AC -1 Heat Pump (2500 Ibs.). Please call if you have farther questions, Sincerely, (1 ►111 R bort Bourdagos, P.E. Pr Sident Nelson- l3ourdagos A Division of Poggemoyer Design Group, Inc. Enclosure: partial roof plan CC: Haynes Lund RECEIVED CITY OF TUKWII-A ~'sf4,VAL i� exPIRu ocToBER as M 2000 '' 0 1 41111 JAN 1 9 2000 NELSON-BOURDAGES a Division of Poggemeyer Design Group, Inc. . ; S 12,Sixth Street South, Suite 202 • Kirkland, WA 98033 (425) 827 -5995 • Fax (425) 828 -4850 PERMIT CENTER January 14, 2000 Mr, Duane Griffin Building Inspector, City of Tukwila 6300 Southcenter Boulevard Tukwila, WA 98188 Dear Mr, Griffin: RE: lntergate West Corporate Park Building C Rooftop Units Tukwila, WA The roof, and the entire structure, has been designed to adequately support the roof mounted air handling units. The gravity and lateral loads (seismic zone 3) have been reviewed in accordance with the 1997 edition of the Uniform Building Code. Reference: Mechanical drawings by Parrott Mechanical, Inc., sheets M0,0 and M1,7, dated December 22, 1999. Roof mounted units include air handling units AHU-3 (6000 lbs.) and AHU -4 (6000 lbs.) Please call if you have further questions. Sincerely, Robert Bout ages President Nelson•Dourdagos A Division of Poggomoyer Design Group, Inc. CC: Haynes Lund EXPInss OCTOOER 24 wwr.,�y JAN 1 8 2000 NE SON•BOURDAGES a Division of Poggemeyer Design Group, Inc. 512 Sixth Street South, Suite 202 • Kirkland, WA 98033 (425) 827 -5995 • Fax (425) 828 -4850 • _..____ a Division 512 Sixth Job " N�LSON•gOUitDAG�S Consulting Engineers ofPoggemeyerDesignCroup .Inc. Street South. Suite 202 • Kirkland. WA 98033 (425) 827.5995 • FAX (423) 828.4850 Ma•e •y . # Date / d• No. IAi • Date 5 eet No. )/ Description EG • UN 1 c. 241414- , r �%r ERMRCOORDCOPY'" PLAN REVIEW /ROUTING SLIP ITir:N.UMBER: Mi2000 -014 DATE: PROJECT NAME: ZAMA NETWORKS. r.XX Original Plan Submittal Response to Incomplete Letter # ,.,..r .,.Response to Correction Letter # ,,,,._____.Revision # .r„ After Permit Is Issued DEPARTMENTS: 1 �j Bu ding Division II Fire Prevention • Planning Division ry. '00G Public Works ❑ Structural ❑ Permit Coordinator C ■ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ Complete Comments: DUE DATE: 1- 20-2000 Not Applicable ❑ TUES /THURS ROUT NG: Please Route Structural Review Required El No further Review Required El REVIEWER'S INITIALS: DATE: I1PPROVALS_OR CORRECTIONS: ((en days) DUE DATE 2-17-2 00 Approved ❑ Approved with Conditions Es/ Not Approved (attach comments) El REVIEWER'S INITIALS: DATE: CORRECTION J RMINATION: DUE DATE Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ REVIEWER'S INITIALS: DATE: UPRROUTE.DOC 5/99 • City of ThkWiIa Steven M. Mullet, Mayor Fire Department Thomas R Keefe, Flre Chief January 25, 2000 Fire Department Review Control #M2000 -014 (512) Re: Zama Networks - 12101 Tukwila Intl. Blvd., Suite # Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1742) H.V.A.C. systems supplying air in excess of 2 000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply-air duct served by such equipment. Smoke detectors shall be labeled by an approved for air duct installation and shall be instal l installed in accordance with the manufacturer's installation instructions. (UMC 608) Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2)) Local U.L. central station supervision is required. (City Ordinance #1742) Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1742) All new fire alarm systems or modifications to Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206.575.4404 Fax: 206.575.4439 City of Mukha Steven M. Mullet, Mayor Fire Department Thomas R Keefe, Fire Chief Page number 2 existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) Call the Tukwila Fire Department at 575••4407 for approval of any system shut down. Have job site address, name and the Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #1742) 2. Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) 3. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 4. This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, Srae The Tukwila Fire Prevention Bureau cc: TFD file ncd Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206. 575.4404 • Fax: 2064754439 • DEPAR NT •OB :LABOR AND" INDUSTRIES :_ REGISTERED AS • PROVIDED - BY: LAW :AS CONST %'CONT:.. GENERAL 4Je l.]Y ,•t • erfl �l RBdXBT;_ #� = EXP, DATER; ;CC01.0, MCKIN. * ;372 10,42/31.'/2000; -= {{pp EFFECTIVE-':DATE. ;.,y, Z. • 08/20/1963 J,41J2s :+Iw'.+.3•K Aawe- tSr 47, if .') %5E` 'ti.: cw" `.., '-; %.:. •. ;.•a.i: rf'>rr:l rii:,: }«:: ' . MC. KINSTRY CO �.,,..,. 5005': 3RD -AVE "S- ;�.�.�_ - -- `PO1BOX 245.67' _......._. -... SEATTLE WA 98124 -0567- ros.os:•000 t ) • 6-3 &24_ en.t i v • � � �d 0 Cehr-4-se • la fio9/1 5 • VOLTS VOLTAGE AC. VERTICAL VENDILATON VENTWATON FAN WASTE WET BULB WITH WIRE SIZING. AMPS 5005 3al . AV South P.0.8oz 24567 -' Sea184 MA 98124 (206) 762 -3311 far. (206) 7622624 5400 AE Cokohbio AAd Pottkr4 On 97218 phone far ) 331 -6903 PERMIT II CORPORATION ARCHITECTURE ,,ROUP nstry REVISIONS ISSUE DATE Al 6awige and letter' matelot appearing Twde ea NN9 the original and unpuhPdnd wai of the Sobel and the sans may net be dupleatsd, used E without the 'Akan canant of 1M Sabo/ QapamBorL SYMBOLS PIPE. FITTINGS. VALVES - LEGEND CW COLD WATER PPE GS GS GLYCOL WATER SUPPLY GR OR GLYCOL WATER RETURN HPE CO CD CONDENSATE DRAIN PIPE PCD PGD PUMPED CONDENSATE ARAN PIPE O O 3 ti Q INSTRUMENTATION & CONTROL - LEGEND DUCTWORK LEGEND DOUBLE LINE RECTANGULAR DUCT ,RECTANGUuR ..DUCT SUPPLY MR DUCT - TURNING DOWN OR AWAY J RECTANGULAR DU j EXHAUST OR RETURN NR DUCT - TURNING UP OR TOWARD I RECTANDULAR DUCT I EXHAUST OR RETURN AIR DUCT I ' TURNING DOWN OR AWAY L ROtAAO AtICf b RDIINIO DUCT b (v) O SUPPLY NR FEOM DIRECTION RETURN AIR FLOW DIRECTION SUPPLY AIN DUCT - TURNING UP OR TOWARD ROUND DUCT - TURNING UP OR TOWARD ROUND DUCT -. TURNING DOWN OR AWAY TRANSITION TURNING VANES SUPPLY GRILL RETURN OR MUST GRILLE VOLUME (BALANCING) DAMPER MOTOR OPERATED DAMPER ARE DAMPER S/FD . COMBINATION SMOKE & ARE DAMPER PIPES UP APES DOWN PIPE PITCHED DOWN IN DIRECTION OF ARROW DIRECTION OF HAW N PIPE CAR OR PLUG UNION F1.DOBLE CONNECTOR STR WYE STRNNER WE STRAINER W/ DOW DOWN VALVE RV' PRESSURE RELIEF VALVE CIA alma VALVE 01 GATE VALVE 0/ BAIL VALVES BFV : BUTTERFLY VALVE CONTROL VALVE PUMP THERMOSTAT or WALL SENSOR FS FLOW SNITCH GENERAL - LEGEND • not controlled •• per actual equipment heat output provided by Spading Ventilated spaces(ie .exhaust fan on at 110F) - Parking level electrical room Parking' level VFD room 1 ( M0.00 NEW MECHANICAL YIORK EXISTING WORK & NEW WORK OTHER THAN MECHANICAL DETAIL DR DIAGRAM NOURRA SHEET NUMBER WHERE DETAL/DIAGRAM SHOWN SECTION LETTER SHEET NUMBER WHERE SECTION SHOWN PUN NUMBER SHEET NUMBER WHERE, PLAN SHOWN DETAIL REFERENCE OUTUNE CENTERLINE EQUIPMENT CRlL -OUT ABBREVIATIONS AC AR CLNDIIIOtAIG A U AR CUGHRONING. UNIT AFf ABOVE. FASTED FLOOR NP BTU NTUH BLDG CB co CFY CONS E 08 DDC BRAKE HORSEPOWER 811108 MEWL Ulf BRITISH 'DERMAL UlT PER HOLM BULLING CIRCUIT BREAKER CONDENSATE ORA% CONTROL DAMPER CUBIC FEET PER MIME CONDENSATE COLD WAER DRY. RIB 08W DON. CONTROL DEPT DEPARTMENT ON 50111 ECG EGGCRAIE fs r c FILE ELECTRICAL EMS ENERLY YARY,EIIE11f SYSTEM EQUIP EQUFMQd ESP EXTERNAL SGRC PR655UE E70SIIYC DPANSON FAHREIEER FIRE DMPElt FLOOR DRAIN FU IL LOAD AMPS COMBRAT10N E E/SMOIE SNIPER FOOT or FEET P * r; 3 kFRO GAIN GC GPM CR OS HD 11085 IP HR Hr RAE N LOS MAX Nex MAC MECO III YID NOM REIATNE MNORY ROOM REVOLUTIONS PER MINUTE RIO ROOFTOP UNIT SA SUPPLY AR sENS.. SENSIBLE SP STATIC PRESSURE FT SOLAJE FEET TOP TRANSVERSE. war FLANGE CONN TSP TOTAL STATIC PRESSURE TYPICAL UNINIERRUPTABLE.POWER SUPPLY FILE COPY Plan Check approvals are dPlan hecand rovalsaiof 1 understand that the an violation of con- , subject to erro t authorize the Receipt of :adop does de rdinanc know don - ractr' co of o n` f�ctor'scoPY:of app rovedpia t 13v Date Permit I \ rig? c9 VOILA RC) cD B .g 20 _ - p SIIOON CONSULTANTS Tenant Improvement rot` at intergate West 12201 Tukwllla_International Blvd. TukwBila, WA DRAWING TITLE: PROGRESS DATE FILE: 10 -D7 -99 PLOT: PROJECT NUMBER: 3$340 DRAWN BY: U.E CHECKED BY: DM. APPROVED BY: DRAWING INDEX Winter DWG. NO. DESCRIPTION, SCALE M 0.1 ' LEGEND, ABBREVIATIONS. .. & DRAWING INDEX NONE M 0.2 '.. PARTIAL SITE PLAN 1/8 = -0.. o___. I,: Lights .Equipment M 3.01 GARAGE LEVEL P2 - INAC PLAN 1/8' =1. -0' M 3.1A 1ST FLOOR PUN ,- UNDERFLOOR HVAC 1/8 " =1 M 3.18 - 1ST FLOOR PLAN - OVERHEAD HVAC .. 1/8' =1 -0' '., M 3.2 2ND FLOOR. PLAN 1/8 - =1' -0• N 3.3 3RD FLOOR PLAN 1/8' =1' -0 - .. M 3.5 ROOF PLAN ''- INAC 1/8- =1' -0' M 4.1 DETAILS : .. NOTED M 42 DETAILS ....NOTED N 5.1 .. DIAGRAMS NONE. M 8.1 SCHEDULES : NONE M 8.2 SPECIFICATIONS NONE 1.5 - 0 S P 3.02 GARAGE LEVEL Pt -' PLUMBING PUN' t /R' =I'-0' p P 3.1A 1ST FLOOR PLAN - UNDERFLOOR PLUMBING • 3.1B 1ST FLOOR PLAN - OVERHEADPLUMBING r P P 32 2ND FLOOR PLAN - PLUMBING P 4.1 : DETAILS & SCHEDULES 20 245 - 200 20 1.2 1.5 0 VOLTS VOLTAGE AC. VERTICAL VENDILATON VENTWATON FAN WASTE WET BULB WITH WIRE SIZING. AMPS 5005 3al . AV South P.0.8oz 24567 -' Sea184 MA 98124 (206) 762 -3311 far. (206) 7622624 5400 AE Cokohbio AAd Pottkr4 On 97218 phone far ) 331 -6903 PERMIT II CORPORATION ARCHITECTURE ,,ROUP nstry REVISIONS ISSUE DATE Al 6awige and letter' matelot appearing Twde ea NN9 the original and unpuhPdnd wai of the Sobel and the sans may net be dupleatsd, used E without the 'Akan canant of 1M Sabo/ QapamBorL SYMBOLS PIPE. FITTINGS. VALVES - LEGEND CW COLD WATER PPE GS GS GLYCOL WATER SUPPLY GR OR GLYCOL WATER RETURN HPE CO CD CONDENSATE DRAIN PIPE PCD PGD PUMPED CONDENSATE ARAN PIPE O O 3 ti Q INSTRUMENTATION & CONTROL - LEGEND DUCTWORK LEGEND DOUBLE LINE RECTANGULAR DUCT ,RECTANGUuR ..DUCT SUPPLY MR DUCT - TURNING DOWN OR AWAY J RECTANGULAR DU j EXHAUST OR RETURN NR DUCT - TURNING UP OR TOWARD I RECTANDULAR DUCT I EXHAUST OR RETURN AIR DUCT I ' TURNING DOWN OR AWAY L ROtAAO AtICf b RDIINIO DUCT b (v) O SUPPLY NR FEOM DIRECTION RETURN AIR FLOW DIRECTION SUPPLY AIN DUCT - TURNING UP OR TOWARD ROUND DUCT - TURNING UP OR TOWARD ROUND DUCT -. TURNING DOWN OR AWAY TRANSITION TURNING VANES SUPPLY GRILL RETURN OR MUST GRILLE VOLUME (BALANCING) DAMPER MOTOR OPERATED DAMPER ARE DAMPER S/FD . COMBINATION SMOKE & ARE DAMPER PIPES UP APES DOWN PIPE PITCHED DOWN IN DIRECTION OF ARROW DIRECTION OF HAW N PIPE CAR OR PLUG UNION F1.DOBLE CONNECTOR STR WYE STRNNER WE STRAINER W/ DOW DOWN VALVE RV' PRESSURE RELIEF VALVE CIA alma VALVE 01 GATE VALVE 0/ BAIL VALVES BFV : BUTTERFLY VALVE CONTROL VALVE PUMP THERMOSTAT or WALL SENSOR FS FLOW SNITCH GENERAL - LEGEND • not controlled •• per actual equipment heat output provided by Spading Ventilated spaces(ie .exhaust fan on at 110F) - Parking level electrical room Parking' level VFD room 1 ( M0.00 NEW MECHANICAL YIORK EXISTING WORK & NEW WORK OTHER THAN MECHANICAL DETAIL DR DIAGRAM NOURRA SHEET NUMBER WHERE DETAL/DIAGRAM SHOWN SECTION LETTER SHEET NUMBER WHERE SECTION SHOWN PUN NUMBER SHEET NUMBER WHERE, PLAN SHOWN DETAIL REFERENCE OUTUNE CENTERLINE EQUIPMENT CRlL -OUT ABBREVIATIONS AC AR CLNDIIIOtAIG A U AR CUGHRONING. UNIT AFf ABOVE. FASTED FLOOR NP BTU NTUH BLDG CB co CFY CONS E 08 DDC BRAKE HORSEPOWER 811108 MEWL Ulf BRITISH 'DERMAL UlT PER HOLM BULLING CIRCUIT BREAKER CONDENSATE ORA% CONTROL DAMPER CUBIC FEET PER MIME CONDENSATE COLD WAER DRY. RIB 08W DON. CONTROL DEPT DEPARTMENT ON 50111 ECG EGGCRAIE fs r c FILE ELECTRICAL EMS ENERLY YARY,EIIE11f SYSTEM EQUIP EQUFMQd ESP EXTERNAL SGRC PR655UE E70SIIYC DPANSON FAHREIEER FIRE DMPElt FLOOR DRAIN FU IL LOAD AMPS COMBRAT10N E E/SMOIE SNIPER FOOT or FEET P * r; 3 kFRO GAIN GC GPM CR OS HD 11085 IP HR Hr RAE N LOS MAX Nex MAC MECO III YID NOM REIATNE MNORY ROOM REVOLUTIONS PER MINUTE RIO ROOFTOP UNIT SA SUPPLY AR sENS.. SENSIBLE SP STATIC PRESSURE FT SOLAJE FEET TOP TRANSVERSE. war FLANGE CONN TSP TOTAL STATIC PRESSURE TYPICAL UNINIERRUPTABLE.POWER SUPPLY FILE COPY Plan Check approvals are dPlan hecand rovalsaiof 1 understand that the an violation of con- , subject to erro t authorize the Receipt of :adop does de rdinanc know don - ractr' co of o n` f�ctor'scoPY:of app rovedpia t 13v Date Permit I \ rig? c9 VOILA RC) cD B .g 20 _ - p SIIOON CONSULTANTS Tenant Improvement rot` at intergate West 12201 Tukwllla_International Blvd. TukwBila, WA DRAWING TITLE: PROGRESS DATE FILE: 10 -D7 -99 PLOT: PROJECT NUMBER: 3$340 DRAWN BY: U.E CHECKED BY: DM. APPROVED BY: Summer Winter • Odd DB _ _ 'Is � Indac DB " .. - - Indoor Envelope o___. I,: Lights .Equipment Exhaust Acoustic S DB RH Slab Glazing SC Wall U 1-11 sens. Btu :ea. latent Btu ea. vent Cfm per person watts per sf watts per sf watts /btuh lg Offices Areas 85 67 75 • 24 70 • NA 0.450 0.140 -' 140 245 200 20 1.2 1.5 - 0 40 Conference Rooms 85 67 75 • 24 70 • NA NA 0.140 20 245 - 200 20 1.2 1.5 0 35 Corridors 85 67 75 • 24 70 • NA' NA 0.140 200 245 200 20 - '12 0 - 0 40 Rasa Room 85 67 75 • 24 70 • NA NA NA 140 245 200 20 1.2 - 3480 WATTS ',0 .40 Rasa Equipment Room 85 67. 75 • 24 70 • NA NA NA NA 245 200 20 1.2 - 5220 WATTS 2,810 - NA UPS Room 95 68 72 50% 24 72 50% NA NA 0.140 NA 245 200 20 1.2. -. •• 2.180. NA DC Rectifier Room 95 68 72 50% 24 ' 72 50% NA NA 0.140 NA 245 200 20 -. 1.2 -: •' '' 0 NA Server Room 95 68 72 50% 24 72 50% 0.056 NA 0.140 1000 ..245 200 20 1.2 50 - 0 NA VOLTS VOLTAGE AC. VERTICAL VENDILATON VENTWATON FAN WASTE WET BULB WITH WIRE SIZING. AMPS 5005 3al . AV South P.0.8oz 24567 -' Sea184 MA 98124 (206) 762 -3311 far. (206) 7622624 5400 AE Cokohbio AAd Pottkr4 On 97218 phone far ) 331 -6903 PERMIT II CORPORATION ARCHITECTURE ,,ROUP nstry REVISIONS ISSUE DATE Al 6awige and letter' matelot appearing Twde ea NN9 the original and unpuhPdnd wai of the Sobel and the sans may net be dupleatsd, used E without the 'Akan canant of 1M Sabo/ QapamBorL SYMBOLS PIPE. FITTINGS. VALVES - LEGEND CW COLD WATER PPE GS GS GLYCOL WATER SUPPLY GR OR GLYCOL WATER RETURN HPE CO CD CONDENSATE DRAIN PIPE PCD PGD PUMPED CONDENSATE ARAN PIPE O O 3 ti Q INSTRUMENTATION & CONTROL - LEGEND DUCTWORK LEGEND DOUBLE LINE RECTANGULAR DUCT ,RECTANGUuR ..DUCT SUPPLY MR DUCT - TURNING DOWN OR AWAY J RECTANGULAR DU j EXHAUST OR RETURN NR DUCT - TURNING UP OR TOWARD I RECTANDULAR DUCT I EXHAUST OR RETURN AIR DUCT I ' TURNING DOWN OR AWAY L ROtAAO AtICf b RDIINIO DUCT b (v) O SUPPLY NR FEOM DIRECTION RETURN AIR FLOW DIRECTION SUPPLY AIN DUCT - TURNING UP OR TOWARD ROUND DUCT - TURNING UP OR TOWARD ROUND DUCT -. TURNING DOWN OR AWAY TRANSITION TURNING VANES SUPPLY GRILL RETURN OR MUST GRILLE VOLUME (BALANCING) DAMPER MOTOR OPERATED DAMPER ARE DAMPER S/FD . COMBINATION SMOKE & ARE DAMPER PIPES UP APES DOWN PIPE PITCHED DOWN IN DIRECTION OF ARROW DIRECTION OF HAW N PIPE CAR OR PLUG UNION F1.DOBLE CONNECTOR STR WYE STRNNER WE STRAINER W/ DOW DOWN VALVE RV' PRESSURE RELIEF VALVE CIA alma VALVE 01 GATE VALVE 0/ BAIL VALVES BFV : BUTTERFLY VALVE CONTROL VALVE PUMP THERMOSTAT or WALL SENSOR FS FLOW SNITCH GENERAL - LEGEND • not controlled •• per actual equipment heat output provided by Spading Ventilated spaces(ie .exhaust fan on at 110F) - Parking level electrical room Parking' level VFD room 1 ( M0.00 NEW MECHANICAL YIORK EXISTING WORK & NEW WORK OTHER THAN MECHANICAL DETAIL DR DIAGRAM NOURRA SHEET NUMBER WHERE DETAL/DIAGRAM SHOWN SECTION LETTER SHEET NUMBER WHERE SECTION SHOWN PUN NUMBER SHEET NUMBER WHERE, PLAN SHOWN DETAIL REFERENCE OUTUNE CENTERLINE EQUIPMENT CRlL -OUT ABBREVIATIONS AC AR CLNDIIIOtAIG A U AR CUGHRONING. UNIT AFf ABOVE. FASTED FLOOR NP BTU NTUH BLDG CB co CFY CONS E 08 DDC BRAKE HORSEPOWER 811108 MEWL Ulf BRITISH 'DERMAL UlT PER HOLM BULLING CIRCUIT BREAKER CONDENSATE ORA% CONTROL DAMPER CUBIC FEET PER MIME CONDENSATE COLD WAER DRY. RIB 08W DON. CONTROL DEPT DEPARTMENT ON 50111 ECG EGGCRAIE fs r c FILE ELECTRICAL EMS ENERLY YARY,EIIE11f SYSTEM EQUIP EQUFMQd ESP EXTERNAL SGRC PR655UE E70SIIYC DPANSON FAHREIEER FIRE DMPElt FLOOR DRAIN FU IL LOAD AMPS COMBRAT10N E E/SMOIE SNIPER FOOT or FEET P * r; 3 kFRO GAIN GC GPM CR OS HD 11085 IP HR Hr RAE N LOS MAX Nex MAC MECO III YID NOM REIATNE MNORY ROOM REVOLUTIONS PER MINUTE RIO ROOFTOP UNIT SA SUPPLY AR sENS.. SENSIBLE SP STATIC PRESSURE FT SOLAJE FEET TOP TRANSVERSE. war FLANGE CONN TSP TOTAL STATIC PRESSURE TYPICAL UNINIERRUPTABLE.POWER SUPPLY FILE COPY Plan Check approvals are dPlan hecand rovalsaiof 1 understand that the an violation of con- , subject to erro t authorize the Receipt of :adop does de rdinanc know don - ractr' co of o n` f�ctor'scoPY:of app rovedpia t 13v Date Permit I \ rig? c9 VOILA RC) cD B .g 20 _ - p SIIOON CONSULTANTS Tenant Improvement rot` at intergate West 12201 Tukwllla_International Blvd. TukwBila, WA DRAWING TITLE: PROGRESS DATE FILE: 10 -D7 -99 PLOT: PROJECT NUMBER: 3$340 DRAWN BY: U.E CHECKED BY: DM. APPROVED BY: 1111111111111 .' CORPORATION nstry 1 8"CWS "& CWR SUPPORT ON 4 "x4` PT WOOD. SLEEPERS ON CONCRETE, PAD 1 CT -2 1 renBnt improvement For at Inte°rgate West 12201 Tukwila International Blvd. Tukwila, UA SCALE: 1/16. 1. - 0 " . DRAWING NUMBER: I /_ V RouND 1 r SEE I I LJ ARCHITECTURE GROUP CONSULTANTS REVISIONS DRAWING TITLE: FlLE: '.. PLOT: Mechanical Contractors and Figbars 5005 Jed Ave South P.O.Se r 24567 Sz[8S Wm 98124 phone / X4 762 -2624 5460 NE Columbia 8Ad Portland, Or. 97218 phone far � _ 331 - 6903' PERMIT ISSUE ISSUE DATE N'dmeigs and eaten material appentien Wein =aub the aaipid and u iatihedeark df the Sate/ Carps and the a dp n may not be icabd, aced or dYai without the written canned of the SabN Cmpmahon. PROGRESS DATE 0.O1 -89 PROJECT NUMBER: 35340 DRAWN BY: JE. CHECKED BY: ` DP'L 5//80955 37: RECEIVED CITY 8, T6%, __JAN 1 9 2000 _Ca 2I SITE PLAN MAIN ELECTRICAL 2000 KW GENERATOR VIBRATION ISOLATORS (BY GENERATOR MFG.) SPRING HANGERS 12" EXHAUST PIPE • INTAKE SOUND TRAP (42'8'X5 M3.01 SCALE: 1/ = 1 -0" GENERATOR ROOM AIR INTAKE Q ('ring Q SOLID NOSE CONE 1 T GARAGE LEVEL P2 - HVAC PLAN END, MEW AT SOUND TRAP 4• FIBERGLASS INSULATION ACOUSTICAL BAFFLE DETAIL 22 GAUGE PERFORATED STEEL 16 GAUGE SOLID SEPTUM II ®® I�® ACOUSTICAL BAFFLE • 2" PERE: LINER RADIAT -SOUND TRAP NO N WIDTH 16 SHEET METAL X;iAUST f RILL= PIPE SLEEVE ACOUSTICAL SEALANT I "FOS & 3/4 "FOR CAP FOR FUTURE GENERATOR. EFF A:, =' GAiLLE I--1/2"Fos A FOR SUPPORT FROM CEILING. It EXHAUST LOOP. (2.5 ` TH I.. [ -1 i (0 G CK) . C . ) I [[ 1 ,. I. i { E�lE+<_C,TO' t t ! [ i [ =' � R [ Wit, Y3 iH Y ; rr J r ' I , . zapaa GENERATOR , ' / 2 L - t i z.--r r • I h � F �' � N. =1 = _ �__ J__ _ -__- - F-- -- I \ q q.. x ► j i ) I :x= MET.. EVER L J �r I l G ca r�cc ■ GENERATOR � R - z i t % � / �_c I 5 0 SOUK TRAP r f--� ) / - } - ✓ ' I 5 C T ; v . . 5 l a = , E 1 TRANSITION A T T E N U A T O R �„n„J r „ , . . , 1- - 1 i I j 1 ( DETAIL -� , Funik I L � FANS 1 1 — — I \ - L -� I ' 1 I ` \ 1 - STC -50 R ARTITION i J ' , I 4 ♦a c- ` (BYi aC.)i Mann - I 1 1 1 - I I I rf<C: ,4:fIBER ■ L - - I I I i�2T t - FLOOR DRAIN ----"El I ; ,laoRioRa .l3 � 3 '0"MIN STC 50 PARTTIO �J 1"FOS & 3 /4"FOR CONNECTION TO GENERATOR FUEL PUMP. TERMINATE SECONDARY PIPING ABOVE GENERATOR PIT NOT ABOVE ENGINE. 12' MAXIM 11-51 MUFFLER (BY E.C.) 16” MAXIM FPE SILENCER (BY E.C.) SEE DETAL D 6 EXHAUST. PIPE PROGRESS DATE: Ip -07499 FILE: PLOT: PROJECT NUMBER: 35340' 2• PIPE INSULATION DRAWN BY: JE. (WITH METAL JACKET) CHECKED BY: Pfl APPROVED BY: DRAWING TITLE :, DRAWING NUMBER i NOTE: EXHAUST PIPE INSULATION NOT SHOWN GENERATOR A NOISE CONTROL (SECTION VIEW Ai•/1TifVhi RADIATOR nFTeln [" EXHAUST , PIPE PENETRATION DETAIL (SECTION 4� D ETAIL D VIEW) EY CO RAUO ARCHITECTURE GROUP CONSULTANTS REVISIONS Mechanical Contractors and Engineers 5005 34 Ave South P.O.RA 24567 Sm[tG Wa. 98024 phone (206) 762-3311 far (206) 762 -2624 5400 AE Colombia tAd Porowd, Or. 97218 phone / (a 331 -6903 RECEIVED CITY OF"MEM 4 nstry PERMIT 155LE 1245-99 ISSUE DATE AM- dmskgs and mitten =tonal appoint bait conibus the original and upBT bid week 5sbq mid the sane mq not be *foot d. seed or= without the written conned of the Sbsy Carpmmtkn. Tenant Improvement For at Intergate West 12201 Tukwila International 6Ivd Tukwila, WA GARAGE LEVEL P2 I4vAC PLAN 3. a--E, a (FUTURE) SUPPORT PIPING ON FLOOR -SLEEVE THROUGH CONC. 8 CWS i & (2)6'CWR DOWN TO 000UNG' TOWER FOR CONDNUATION SEE MO.2' 5005 40 Ate South P.O.Bar 24567 5m(Be, Mb. 98124 la ) -2624 5400 NE Columbia Ad Pa1Bm74 0: 97213 phone (501) 351-690.3 fax ):231 -6907 M3:1A 5 J 7.5 EXPIRED M2000 -014 CONSULTANTS EY CORPORATION t ARCHITECTURE GROUP PERMIT 15 12=1 s-99 REVISIONS ISSUE DATE A dmaiga:ud:ariin matrid weadng heath canaille N. original l and unpuhided walk 1 thaSaboy not be dupthated, toed or= and the soma without .aril n camera at the Sabay OaPaaBa- 'Tenant improvement for at Intergate West 12201 Tukwila International Blvd. Tukwila WA DRAWING TITLE: , FIRST FLOOR PLAN UNDERFLOOR NVAG PROGRESS DATE: 10.687 -98 FIRST FLOOR PLAN - UNDERFLOOR HVAC SCALE 1/8" = 1' -O" DRAWING NUMBER: FILE: PLOT: PROJECT NUMBER: 35340 DRAWN BY: J.E. CHECKED BY Dpi. APPR0Lc6 BY::', RECE4ED.1 9 jj I i rlrn - . inns 1 9600 l I -16'4 WC'? 16'4 DUCT W /SCREENED OPNG. �5 -1090 3 STACK CALLY PIPES 36z16: VERTI —RUN TIR1S MODEL.300RL SWG. ALONG WALL OR EQUAL CORPORATION M3.113 S 125 10x6 SWG W /DBLDEFL & oeo (8 TYP) FIRST FLOOR SCALE: 1/8' 1' -0' EXPIRED M2000 -014 ARCHITECTURE GROUP CONSULTANTS REVISIONS ISSUE DATE PERMIT 1591E 12 : g? la drawings and eaten makend eppmint bemfi rnlWLrts the atyisi ad: apeliehed work af. the Cwawo6on % l the me may not he duplicated. wad a poroti d *Mout' the *raw conned of the Sobel Corpaatkn Tenant improvement for at Intereate West 12201 Tukwila international Blvd. Tukwila, WA DRAWING 1111: PROGRESS DATE 10.07_99 DRAWING NUMBER: FILE: RECEIVED CIN Of NKWILA JAN 19 2000 3 1 i iisfry FIRST FLOOR PLAN OYERFEAP IIYAC PLOT: PROJECT NUMBER: 35340 DRAWN BY: JE. CHECKED BY: DM aPROVED BY: - m , EC -1 I4x14 Sl�,l 200 OSA 18x20 1 20 DUCT! SOX 71EC-2 -_ 32'0 METAL DUCT EC -2 z S -325 14x12 StM S-325 _ EF GREENHECK MODEL CUBE -14-3 O.625'. SP.. _ 1/3 HP. EC -2 W /ROOF CURB. BDD, & BHDSCREEN 180 UP TO ff 2 ON ROOF. �-- -- - rJ ff ( E -4360 CFM 26 4 UP GREENHEgC,YODEL CUBE -21- 1.25 1 -1/2 HP. Nr /ROOF CURB. BDD i s �- -28 0 Dti BIRDSCREEN UP THRU ROOF 6 TO HVU T METAL • 32! DUCT SOX i ,• DUCT (APPROX. 28' OH — ,• STRAIGHT,,DUCT SOX UP) 32'0 METAL DUCT •-36x24 (A� SCREENED OPNG. _2410. DUCT SOX---- 3RD FLOOR LOBBY TO BE SERVED BY LEVEL 3 & 4 AC UNIT- ="12•q -36x12 SWG KRUEGER MODEL 880H OR EQUAL FUTURE 54 SHAFT DN' TO 2ND FLR CEILING X14 "0 METAL DUCT 1 Li ?miry Tenant Improvement for at Intergate West 12201 Tukwila International Blvd. Tukwila, SM "DUCT SOX. FABRIC DUCTS IS CLASSIFIED BY UNDERWRITER'S:lABORATORIES IN ACCORDANCE WITH THE FLAMMABILITY AND SMOKE DEVELOPED REQUIREMENTS OF NFPA -90A - - ----- MAX. -FLAME SPREAD INDEX -OF 25 MAX. SMOKE DEVELOPED INDEX OF 50 (5 TYP) PHASE II NOTES: 1. OSA DUCT TO BE SECURELY ATTACHED TO HEAT PUMP (TYP) 2. HHP -3 THRU HHP -7 AND CRU -21 & 22 REQ. EMERGENCY POWER. 3. PROVIDE METAL DUCT FITTINGS WHERE INDICATED BY ® lean mre�.. CORPORATION ARCHITECTURE GROUP CONSULTANTS REVISIONS ISSUE' DATE Mechanical Contactors and Engineers 5005 3rAAa UAN P..O.&a 24567 Sea ME: 98124 lac (206) 762-3311 4 5100 PE Columbia 66d. Portland, Or. 87218 phone lac 50Q .T3! -6903. PERMIT 155UE L2-15-99 N- 6arinyr.ad -wit n- mdrrid gumming Win canasta Sa ai6 d id vyuhidad wade ditheSabq _ Wheat Um mitten Sahy Oar oratic . DRAWING TITLE: SECOND FLOOR PLAN HVAC PROGRESS DATE:: i6 -07 -99 SECOND FLOOR PLAN - HVAC •..SCALE: 1/8 =:1' -0 FILE: PLOT: PROJECT NUMBER: 35340 DRAWN BY J.E. CHECKED BY: P.M. APPROVED BY 1 EY CAP FOR FUTURE VAV BOX (FUTURE) 1000 Cal SERVED BY 16'a —'? k 4TH AC U NR \ (FUTURE) 575 Jiel Ave South Ratloa 24587 SaatUE Ytt 96124 plane 1 �J 762-2624 5400 NE Columba BIKE fb 96n x 97218 phone f ) 231 -6403 SEE SHEET M3.213NG. ---I M3.3 THIRD FLOOR PLAN - HVAC SCALE: '. /8' = t' -0. M200 14 OPI EY CORPORATION ION ARCHITECTURE GROUP CONSULTANTS ?Wry PERMIT ISSUE 12 -15-99 REVISIONS ISSUE DATE N_dmsigs aM_meal mduid apatig bomb conollde Be odgin31 ad upublitad seh aP Be and the sun mg not to dupicat d, used or= without the written conceit of the Sobs& CapmaUon. Tenant improvement: For T Vi+ '0 R x: 5 DRAWING TIRE: THIRD FLOOR ( PLAN HVAC DRAWING NUMBER: PROGRESS DATE: 10.07 -99 ALE: PLOT: at Intergate West 12201 Tukwila International 6Ivd. Tukwila, WA PROJECT NUMBER: 35340 DRAWN BY: J.E. CHECKED BY'' PJt =' APPROVED BY: RECEIVED CITY OFTUKWILA JAN 1 9 2000 1'13 3 1.5 321. METAL DUCT VI/R-7 INSULATION ABOVE ROOF 32� DUCT SOX BELOW ROOF DOWN. (SUPPLY DUCT ONLY) —RA DUCT TO BE ALL SHEET METAL . 321I ON W/R-7 INSULATION ABOVE ROOF 20 TON HEAT PUMP HOW. DISCH. 4 M3.5 I 5 ROOF PLAN - HVAC SCALE: ix ( 6 ( M2,000-01 EXP ( A B ' C A EY CORPORATION ARCHITECTURE GROUP CONSULTANTS REVISIONS ISSUE DATE DRAWING TITLE: Media &al Contractors and Thaheers 5005 3rd Ave South P.aftar 24567 Seottft lier. 98124 phone (206) 762-If hoc (200 762-2624 5606 hr Columbia Nut Portland, Cr. 97216 phone (503) 2.31-6903 RE (504 331-6995 PERMIT 1651E 12 Al *whip and melon =bend ongoing her* corrtithe the ariolnel cod unpublehed yak el the Sew I6 the some row not be dupieated, end or without the written cement of the Sobel Corporation. • endnt improvement for ZAMA NETWORKS at Intergate West 12201 Tuktulla International 15lvd. Tukwila, WA V-07-99 ROCF FLAN PivAC PROGRESS DATE: FILE: PLOT: PROJECT NUMBER: 35340 DRAWN BY: J.E. CHECKED BY: DX APPROVED Ft DRAWING NUMBER: RECEIVED CITV OF TUKWILA JAN 11 2000 141013 PERMIT CENTER BUILDING WAIL FLEXIBLE METAL HOSE ASSEMBLY NOT TO SCALE FURNISHED TO SUIT SYSTEM PIPING NOT TO SCALE 1/2 UNE SIZE MV . BACK FLOW PREVENTER END CONNECTIONS SHALL BE ' METRAFLEX- METRALOOP OR EQUAL L CONFIGURATION CONFIGURATION PIPING SEISMIC FLEXIBLE METAL HOSE AIR SEPARATOR AND EXPANSION TANK DETAIL LIVE LENGTH AS DETERMINED FROM M METRAFISEX'METRALOOP' SELECTION CHART FOR APPLICABLE PIPE SIZE &ANTICIPATED MOVEMENT. OR APPROVED EQUAL PRESSURE REGULATING VALVE [GATE VAL - P Mt: ee 1 r MAKE -UP WA SEE PLUMBING FOR CONTINUATION. ISOLATION VALVE `.'' (TYP) ;:' ■11EW1 � CONC SLAB ♦ ON GRADE (PING TO BE ANCHORED ON EACH SIDE OF SEISMIC JOINT FROM PUMP CHEMICAL FEED POT POT FEEDER DETAIL NOT TO SCALE 3/4 TO DRAIN. TO PUMP FOR DUCT SIZE FIR SUPPLY DUCT ALL-THREAD UNISTRUT (TYP SUPPLY';, CEILING MOUNTED HEAT PUMP DETAIL NOT TO SCALE SEE PUMP DETAIL INSULATION ON PIPING WITHIN BUILDING STOP INSULATION AT WALL WATERTIGHT SLEEVE THRU WAIL UNKSEAL OR EQUAL ESCUTCHEON FIRST �� - -- - -- FLOOR ALL RATED WALLS FIRESTOPPING WHERE REQUIRED: WALL ABOVE GRADE . PAINTED. PIPING ® OUTSIOE'BUILDING CO R. ION ARCHITECTURE GROUP CONSULTANTS REVISIONS ISSUE DATE i nsfry ifechatiSAf Cant odors ad fngkears 50aS 3nd Are Sod* P.O.Bar'24567 SeofffL 11A. 98124 phone (2061 762 -2524 540D'IE Cadanbia BA¢ Portland, On 97218 f . (504 531- PERMIT 1551.E 12-15 -99 AI Things and mew mated apaog heaia amd3de The atgird ad apBFdord work of Rh. and the eome may hat he dupewted, wed ar= without the Innen cowed of the SEry Calpmotion. Tanant improvement for at Intergate West 12201 Tukwila International Blvd. Tukwila, WA DRAWING TITLE: DETAILS PIPING FLOOR SUPPORT DETAIL NOT TO SCALE CONCRETE FLOOR COND. WATER SUPPLY & RETURN PIPING THROUGH BUILDING WALL DETAIL (ABOVE GRADE) NOT TO SCALE EXPI Irivems . G cot I PROGRESS DATE: wen-99 FILE:: PLOT: PROJECT NUMBER: 35340 DRAWN BY: JE CHECKED BY: 1 art. APPROVED BY: 18" WATERTIGHT SEALANT CRU TYPICAL SHEETMETAL ANGLE (1864) 2'x2 (TYPICAL 4 SIDES)' APPROX. 10'(L) X 7'(W) WATER DAM DETAIL NOT TO SCALE NOT TO SCALE COMPUTER FLOOR °� � WAVE (0-0011 GO) C p DrI WATER NULL SUPPLY �� FLUID COOLER CONNECTION DETAIL M2000 -0 EXPIRED EY CORPORATION M4.2 3� 0 FLOOR SLAB 2 CONNECTION TO UNTI PIPING cwR O 3/4' DRAIN 1 1 - 11 0111111.- •••"0 0 2 M4.2 k PIPE TO FLOOR DRAIN TYP. COMPUTER ROOM UNIT (CRU) INSTALLATION NOT TO SCALE /2`py Up© o idF I� �1 Y COPPER 2' SCHEDIA.E 40 Cw 7 - DIELECTRIC UNIOII LOCATED INSIDE DRAIN PM. (TYP.) NOTES: pl FULL PORT DILL VALVES 0 CHECK VN.DE ® /M ARC 84ANCYIG VALVE ® ® SESMMALLY RATED BASE © MOISTURE. SENSOR/YOIDEOR/ /MAAII S15'IEY. ® ALL AWING LOCATE N WNER DAM NOTES: I. SEE PLANS FOR. PIPE SIZES AND ROWING. 2. SEE SCHEDULE FOR SIZE OF NR GAOLED CHILLER KEYNOTES: UNION TYP. AUTOMATIC AIR VENTS BUTTERFLY VALVE FLEJMBLE CONNECTOR THERMOMETER ALL DOMESTIC COLD. WATER PIPING LOCATED OUTSIDE OF BLDG. HEAT TRACED AND INSULATE 0 PIPE DRAINS TO DISCHARGE LOCATIONS LOCATED INSIDE BUILDING 0 POWER CONNECTION (BY ELECTRICAL) H STRAINER 0 0 0 0 0 0 t /4" COPPER TUBING TO HUMIDFILR 1 /2 "CW TO TRAP PRIMER I/2 NPCAI Alk SEE FLOOR PLANS FOR PIPE SIZES ALL VALVES ARE FULL SIZE OF PIPE r CONNECTION ®rIL 1 ®1I ECCENTRIC PLUG VALVE (DEZURIK SERIES 100) SILENT, NON - SLAMMING CHECK VALVE 3 M4.2 FLEXIBLE PIPE PUMP HOOK UP DETAIL BUTTERFLY SHUT OFF VALVE RANGE 0 -60 PSI PIPE SIZE SEE.. FLOOR PLANS DOUBLE SUCTION PUMP SUCTION DIFFUSER. MATCH INLET TO PIPE SIZE STRAINER REMOVAL SPACE. MAINTAIN CLEAR ACCESS SUPPORT LEG 3/4" SEAL BASIN DRAIN PIPE TO FLOOR DRAIN! NOT TO SCALE SLAB - ON-GRADE MOUNTING. CONSULTANTS DRAWING TIRE: ARCHITECTURE GROUP "miry achat** Coa raelars Rid 6g"rrers 5005 3a1 Awe South P.O.Bma 24.567 Sea(8y se, 98124 far �J 762-2624 54W1 AE Columbia Bled Por8aa4 On 97218 plow A ( 50 3) .351 -6903 PERHIT ISSUE j2 -8 - REVISIONS ISSUE DATE A -& MM. and "Mn madarid awarbg herein coneblAs the original old rpdai.b.d vak of the Soby Cep= and wino no may. bat be duplicated. and or dtrJo..d without Ba written cancan d the Sab y Corporation. FILE Tenant improvement ,for at Intergate West (220) Tukwila International Blvd. Tukwila, WA PROGRESS DATE: 10-07 -99 PLOT: PROJECT NUMBER: 35340 DRAWN BY: JE. CHECKED BY: D1"C APPROVED BY." RECEIVED '. CIT'OF TUKWIIA JAN 1 9 2000 DETAILS NZIF REDUCED PRESSURE j- BACKFLOW 2' FROM GEN. #1 TO GEN, #1 FROM GEN. #2 TO GEN. #2 CWS 2" BYPASS POT FEEDER LOCATED IN P106 — CWR - - - -) SECOND FLOOR DATA CONTROL LOOP r I I CWS L -- -- G1- -CWR FIRST FLOOR DATA CONTROL LOOP EXPANSION /SEISMIC FLEX CONNECTION ____ _.. I F. L FUEL OIL CIRC. PUMP COALESCING /PARTICULATE FILTER LEAK DETECTOR VALVE & CAP 7-BUTTERFLY VALVE (TYP) TO BMS PIPING TO BUTWING —FOR TO BMS Hy `EXPANSION TANK LOCATED IN P106 roc), U RAFT SLAB) NR SEPARATOR LOCATED IN P106 CWS — —CWR— ANTI - SIPHON VALVE FOOT VALVE LEVEL MONITORING 6' EMERGENCY VENT 2' NORMAL VENT— P I FUEL OIL PIPING DIAGRAM NOT TO SCALE E ARRESTOR 2' INTERSTITIAL. NORMAL VENT 112' DIA X 23 -4' LONG 8,000 GALLON DOUBLE CONTAINMENT STORAGE TANK SEE THE FOLLOWING HOOKUP DETAILS: FLUID COOLER CONNECTIONS. M2000 -014 CONSULTANTS PROGRESS. DATE FILE: IT11cbaucd Contractors awl &gingers, 5005 3ni Awe'.. Soo& P..0$os 24567 Seattl4 NAL 98124 phone / (206J 762-2624 5400 45 CAReneio 81 Portland; Or- 97218 phone / (503W 551 -6903 10 -D1 -99 PLOT: �...: PROJECT NUMBER: ' 35340 DRAWN BY: I J.E. CHECKED BY: ° pM APPROVED BY: RECEIVED. C17V OF7UKWILA JAN 1 9 2000 1 - 1 CORPORATION P -IA I P -TB1 M5.1 NOT SCALE M5.1 NOT TO SCALE I CT -1 O i CONDENSER WATER SYSTEM DIAGRAM BALANCING VALVE BYPASS --L CWR END SUCTION PUMP. POT FEEDER DETAIL. WATER WELL & PUMP -- PERMIT ISl3LE 12 -15 -99 REVISIONS ISSUE DATE ARCHITECTURE GROUP nsfry Oa aid satin matinti pm* henna =gluts =gluts the original and upa idMd work at 1111 Selby drJaed d the um. row 111 dipieabd, u11W or ri0autt the wake =cent at to Saba.. Capom6ac. Tenant improvement for at Intereate West 12201 Tukwila International Blvd. Tukwila, WA DRAWING TITLE: . GIAGRAIM DRAWING, NUMBER: Computer Room Air Conditioning Unit Schedule WA/P. ' DESIG. NRNOcr DIE Tag. /. :... ". CRU -1 thin 6 CRU -11 &12 CRU -13 & 14 MATERIAL BASS' OF 86021 CRU -17, 18,..19. 20 COOL 6" RD. -- .. CRU -7 thru 10 (Future) _ - X 6 CRU -15 & 16 ( Future) ... 1111-18 and 20 are 100% back -up uni Basis of Design .. TINS MODEL MCA 11001111R - -- - DATA AIRE (DAGD -26) DATA AIRE. (DAGU -10) DATA',AIRE (DAGU -30) .'' '..:. DATA':ANE (DAPW- 0534 -PE): Suppy Fan. Type : 24 X 24 forward .curved:. :,. forward curved ..:forward curved : forward curved Sup. Fan Confp.(Blow Thru /Draw Thru) 350 draw thru :. draw thru -: draw thru $100. TINS MODEL NC0 1100 : :.. draw bun Upflow /Downfbw /Ceuing- Mounted : If RD.. Downflow Upflow. '.;Upflow 5-8PR 51D3 Cermq Mounted Sun* CFlA Des 10000 5500 -: 14000 24 X 24 : ' T -BAR SIEEt Supply ESP. 1 .2. 3, 4 0.5 0.5..:. ',0.5 16 X 16 - 24 X 24 0.3 Supply fan :TSP... (ESP + Int. Losses) TRUST M00FL MC0' M00UAR : I ,2.3. ,.:.. DA le RD. 1120 18 X 18 24 X 24 Supply Fan. HP SIEID. 10 3 15 6' Re: t IO 6 X 6 Supply Motor Efficiency sew Per Code Per Code Per. Code - OG2 8" RD. Per Code Quantity of Supply Fans - Leo 51EEL wits M60EL MW'MODIXm I. 2..3.5 ... 503 10" RD: Water Regulating Valves 10 X f0 Yes Yes Yes TINS MODEL YCD MOWI/R I, 2..3. 5 Yes Condenser Water EWT / L.wr 560 ':. 85/95 85/95 : '_85/95 SD.7:L : 85/95 Condenser Heat Removal 12" RD. 600:', 14 X 14 GNB 5D31 711115 MODEL WO 1931XLM1 Condenser Water. Propylene Gycol % DG6 30% 30% 30% :. GXB : 30% Condenser Water Co9 GPM : 75 35. 80 18'X to :.15 Condenser Coil - Pressure - Drop (Ft lid.) - -- 22.9 _.' _.- - 10.3 -_.- - _ . -- .27.8 _.- -._ -- 1155 Cooling Coil EAT (4DB/WB - -- 72 / 60 72 / 60 72 / 60 72 / 60 Cooling Coil LAT (DU/WB) 55/ 55/ : - 55 /. OTt0 55/ (UNIT) Cooling MBH Sensible/Total - 237.9 / .216.0. 87.8 / 85.7 297.2 / 325.3 : NOT USED DTII 49.8. / 50.8 Fitter Eff. ( %) 14: X 14 24 X 24 T-BAR $101.. 111115 MODEL PCS '. 52 Nominal Tonnage :. 25 ton 10 ton. : 30 ton SIEFL 181.15 11000. PCS 5 ton Electric a8 901 OUT SI S1101L BE PER THS SCHEDULE . U.N.O. ON ORAXCXS. NL DIFFUSERS in BINE SEET IETN. OR lSCIBONo t CAN PIF7AIY. STANDARD STIIE F1/991. Fawrt Mut tlxrYxF inn a ■YJa MAIL 30KW 15KW .:'. 30KW 2275/1: Voltage /Phase : 460 / 3 460 /. 3 460 / 3 :. 460 / 3 Unh Foe Load Amps (PIA)' :. 75 37 Minimum Crmwt Ampacity (MCA) 84 43 link Max. Fuse or Circuit Breaker (WOE) 110 25 Factory Mounted Starter Humidifier ': (AU. /hr.) : 221 ;.... :5 . . Overall Height. (itches) 72 72 72 285. Overall 000th (inches). .. 35 Overall Length (inches). 99 62 :.125 51 Weight (lbs.) . 2405 1340 : 2580 Supply Smoke : Detector : by elec. by elec. by elec. by eke. Disconnect by elec. : by elec. by elec. by elec. 110 V. Service Outlet Within 25' : by elec. by elec. by elec. by elec. MODULAR DIFFUSER (DT)(DG)SCHEDULE WA/P. ' DESIG. NRNOcr DIE MAX -CHAR CORE SO FACE 92E MOUNTING MATERIAL BASS' OF 86021 gEMNF6' COOL 6" RD. -- .. 150 _ - X 6 -_, 24 X 24 T-Oow SUED. TINS MODEL MCA 11001111R - -- - t .2, 3, 4 DT2 8" RD. 220. : 8 X 8 24 X 24 T -BAR , 900. TITUS M. YCD MOHAIR 1 ,2, 3, 4 013 10" RD.. ' . 350 10 X 10 24 X 24 T -OAR : $100. TINS MODEL NC0 1100 : 1 2. 3, 4 DT4 If RD.. :500 12 X 12 24 X 24 5-8PR 51D3 - 11015 M00FL IICD 1058)6 1 .2. 3. 4 Des 12" RD. 600'. 14 X 14 24 X 24 : ' T -BAR SIEEt 11111S 1100E1. MCD MODULAR 1 .2. 3, 4 DT6 14' RD.: tow 16 X 16 - 24 X 24 T -&R : 5100. TRUST M00FL MC0' M00UAR : I ,2.3. ,.:.. DA le RD. 1120 18 X 18 24 X 24 T-ONt : SIEID. :111115 MODEL MW: MOOUAR I .2, 3, 4 00 6' Re: t IO 6 X 6 - 'r sew SIFb : tuus eco NOOUAR I. 2, 3, 5 - OG2 8" RD. 220; 8 X 8 - Leo 51EEL wits M60EL MW'MODIXm I. 2..3.5 ... 503 10" RD: 350: 10 X f0 1X98. STEEL TINS MODEL YCD MOWI/R I, 2..3. 5 12" RD. 560 12': X 12 CARD SD.7:L 11015 MODEL LCD.. MOD LeR 1. 2. 1 , 6 -. DCS 12" RD. 600:', 14 X 14 GNB 5D31 711115 MODEL WO 1931XLM1 1, 2, 3 5 DG6 14" RD. 860' 16 ,X 16 GXB SIFFI TITUS MODEL MCD YODUNt I, 2, 3, 5 16" RD. 1120 18'X to GWB STEEL TINS MODFI. MCDIWUm t 2.3; 5 - -- --- NOT USED NOT USED OTt0 - -- - : NOT USED DTII 14" RD. 750 14: X 14 24 X 24 T-BAR $101.. 111115 MODEL PCS '. 52 16" RD. 900: 16'. X 16 24 X 24 :', T- BAR ' ... SIEFL 181.15 11000. PCS MOIE>k 1. 2. 3. 5. 901 OUT SI S1101L BE PER THS SCHEDULE . U.N.O. ON ORAXCXS. NL DIFFUSERS in BINE SEET IETN. OR lSCIBONo t CAN PIF7AIY. STANDARD STIIE F1/991. Fawrt Mut tlxrYxF inn a ■YJa MAIL '. PROVIDE FRAME solemn FOR GAP =NG. -. Rooftop Heat Pump Schedule SERIES VAV FAN TERMINAL BOX SCHEDULE AC -1 Bass of Design TRANE Service : UNIT MANUFACIUliElt INLET DISCH. COOL 'CFM FAN Supply E.S.P. 5;' Supply HP HEATER.; Supply Motor Voltage /Phose 460/3 of Supply Fans FAN. MOTOR Nominal Tons NOTE NO... MODEL Nowell SIZE ON.) PLENUM MAX MIN. CFM:. IN OUT MAX KW D.T. CFM VOLT /PH HP VOLT /PH SPEED NO. FTS- 1 VSFE -t7 15 '10 14:614' 1000 150 1000. 0.5 0.3 12 37.2 1000 460/3 1/3 I 277/I I. 1 thru 5 Disconnects BY ELEC. 110 V. Service .Outlet Within 25' : BY ELEC. NOTE. 1). TRINCK DUCT SIZE SALES AS BOX INLET SIZES. 2). PROVIDE 48 VA TRANSFORMERS : IN FAN POWERED' BOXES W11H CIRCUIT BREAKER RESET. 3). PROVIDE SCR cONTROL FOR FAN MOTOR 4). PROVDE INCLINED ACOUSTICAL BOOT ON SECONDARY NR INLET. 5). PROVIDE SOUND liMOS SHEET METAL DISCHARGE. DUCTS. 6). PROVIDE 5/8" GWB TO BOTTOM PANEL OF THE VAV TERMINAL (IF REQUIRED): Rooftop Heat Pump Schedule Tag # AC -1 Bass of Design TRANE Service : LEVEL 2 OFFICE Supply Fan Type CENTRIFUGAL Sup_ Fan Config.(Blow Thru /Draw'Thm) DRAW.THRU Supply -.. 8,000 Supply E.S.P. 0.8 Supply HP 5 Supply Motor Voltage /Phose 460/3 of Supply Fans 1 Nominal Tons 20 Cooling MBH Sensible' /Total 190/213 Heating Capacity MOH. : 130. AUX HEAT KW : 54 KW Return E.S.P. 48 Return Motor'. Efficiency 200 100 %': Economizer YES Sound Power Levels (dB) Wine reactor Filter. Eff . . ( %) : : 30% Cooling' EER '. : 8.5 EER 7.5 IPLV. Heating efficiency 3 COP 7 day progammable T -STAT YES Factory curb :. :. YES Overall Height (INCHES) 69 Overall Width (INCHES):. 86 Overall Length (INCHES) 123 Total Weight (LBS.) - 2500' Supply Smoke Detector : BY ELEC. Disconnects BY ELEC. 110 V. Service .Outlet Within 25' : BY ELEC. SOUND ATTENUATOR (ST)', SCHEDULE MARK SERVE OIY MAUL cue MDIII SIZE INCIES nom LENGIH F. AREA SO. FT. BCE II EL. FPM MAX P0: OIL) Br615 OF DESEN 8016 ST-1 - _ -.. mouton DEICE -._ 8 - _ - 8724 48 - -, 48 _. 60 -. 160 _ -. 514 _..616 - .- _.IAC.'.MODEL SIPS _... Sr - 2 tEIERATOR NIalE 2 10280 60 48 60 200 514 016 LAC. IMOD. SFS Wine reactor 51-3 OENERATSt OO8OSI 8 10794 54 48 80 . 18.0 806 0.17 G FL 7585 [AC AOO O C to 40 C , O C to 40 C O C'. to 40C 460 I 3 motor': efficiency per WSEC : per WSEC Per WSEC :... VFD Schedule Manufacturer Reliance Reliance Reliance Reliance . model. number VTAC 7 VTAC VTAC7 V1AC 7 Location WO: Room VFD Room VFD Room VFD Room Service P -1A P -1B CT -1 CT -2 Enclosure Nema 12 Nemo 12 Nema 12 Nemo 12 s : yes yes yes ', yes Max. distance between .VFD & motor 100 ft 100 It : 100 ft 100 ft Wine reactor "yes yes '. yes '.yes Main' ".inline fuse and disconnect By E.C. By EC. I ' By E.C. By E.C. .. ambient temp ronge(77F - 77F) O C to 40 C O C to 40 C , O C to 40 C O C'. to 40C Tog f P - IA P - 18 P -IC basis of design Paco Paco Paw model number IF- 4012 -7 LF 4012 - 7 1F 4012 - 7 service CT -1 k_ CT -2 CT-1 & CT -2 : CT -1 C1-2 - -. location Outside Outside Outside gym 750 750 750 ft total head 100 100 100 ft NPSH: 8 8 . 8 RPM 1750 1750 : 1750 % propylene gh'col 30%. 30% 30% mofa..hp : 25 25 motor brake hp : 24 24 24 voltage /phase 460 / 3 : 460 /3 460 I 3 motor': efficiency per WSEC : per WSEC Per WSEC :... Fluid Cooler Schedule Tag f basis of design voltage /Dhose e.w.t/Le.t /design wb model number'. number of cells per tower common sump' for multi tower? tan contg.(force draft, induced draft) fan ertemal etoAc pressure disGwnge .. hood discharge ddnper9 fan motor quantity /hp motor efficiency per WSEC electric pan heater KW condenser water glycol X tower length tower width tower height operating weight (be) Water Pump HP Pressure Drop Thru Tower (psi) CT - I & 2 062.58ORE AMOK 460/3 750 95/83.5/68 FXV- L644 -LM NO INDUCED DRAFT NO NO 1015 YES 12 KW 30% 12' -2' 11' -10' 15 -10 3/4' 23,000 5 16.12 ROOFTOP HEAT AND VENT UNIT (HVU) SCHEDULE UNIT NUMBER IMI -1 ON ROOF SERVICE CODE MIL VFNIMATON SUPPLY FN OIY OF TOTAL SUPPLY CFL 7820 Ott OF MOTOR ELECTRIC HEATER bOLT/PH 460/3 EQUIP. recto 90$) 7,820 1363' a7Grxri' 1. PRO. 50502;557 STATE ENERGY WOE EFFICIENT MOTORS. 2. PROVIDE NSUA1m HOUSING 3. BECIPoSL Wt8RAC. TO PROVOS SUPPLY MR SMOTE DETECTORS, 4. PROVOS 66X E1F.:FILTER 5. PRONOE 100X OUTSIDE AR N1AIE 6 PRONOE AR F10W SWITCH 7. HOKUM EsscRA0% 8. PROVIDE DUCT MOW. SENSOR 9. PROVIDE MOTOROE0 DIAPER IO. PROVIDE ROOF CURL 11. PRONE REMOTE MOUNTED ►0008 SCR CONTROL End Suction Flexible - Coupled Pump Schedule SCI EC2 EC3 EC4 EC7 GI G3 G4 G6 G7 61 R2 R3 R4 ne R6 R7 1200 2400 350 600 5800 2400 350 900 1200 160 100 200 350 600 900 1200 1600 RETURN /EXHAUST AIR GRILLE SCHEDULE ROUND DUCT 854041 0% 680. AN DRAW. 10" RD. 12" RD. 16" RD. to RD. 20" RD NOEL EXHAUST 8" RD. 10" RD: 12' RD: 14 RD. 18": RD. 6" RD. 8" RD. 10" RD. 12" RD. 16" RD. 18" RD. FACE SOE 24.X..12 24 X 24 24X48 12 X 12 24 X 12 24 X 24 24 X36 24 X 48 8X0 10 X 10 12 X 12 16 X 16 18 X 18 24 X 24 24X30 8X8 10 X 1 12 X 12 16 X 16 18 X 18 24 X 24 24X30 STATIC PRESU5E 105$ EGG CRATE RETURN 001 001 001 601 001 0.01 0.01 0.01 002 0.62 0.03 0.03 0.02 0.02 REGISTER EXHAUST 0.02 0.02 0.03 0.03 004 0.02 0.02 NG IESIGIME tED005 NEGLIGIBLE NDIXSE NEGLICHE NEGL1G05 505885 22 25 26 30 30 15 22 26 30 30 3p LOURING T -Bat T-BAR T-Bat T -&R T -BAR T -BAR T-BeR T-&R GAB GM 656 d15 ORB meow I 8195 of OEL51 Al1FEAlY 01100213' MARIA ALUMINUM AWN. AWIRAN ALIAONM SlEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL TITUS 0000. 50/8 71111$ MODEL 50/8 SIDS MOOD. 50/8 TINS MODEL 50 TITUS ADOEL 50 TAUS MODEL 50 BTUS MODEL 50 TINS MODEL no TINS MODEL 35005 TINS'.. MODEL 353RL TINS',. MODEL 3535 TOSS MODEL 3503 TITUS MODEL 3553 1RUS.MOOD. 350H. 710$ 0000. 35. TITUS MODEL 3553 BTUS MOM 350fi TINS MODEL 3535 INS MODEL 35. 11015 MODEL 351MI. ' BTUS MODEL 3553 IIIUS MOOD. 3535 I. 5 1, 5 1.24 1.2.4 1. 1,2,4 I. 2,4 I, 2,4 I, 2,'4 I, 2. 3, 4 I, 2, 3, 4 I, 2, 3,4 1.2,3,4 1.2.3, 4 1,2,3,4 I, 2,3,4 SPITS: 1. SWORD MITE FINISH. 2. PRODS FRSE FOR MOUNTING N GOD CEXING. 3. PROVIDE OPPOSED WADE DAMPER. 4. PROVIDE P00241+ OR TRANSITION 10 RECTAr4CUUR. 5. PROVOS FRAME FOR DUCTED MPUGIONS. Fan Schedule Tag I Basis of Design Mold Number Service Fan Type Fan Config.(In- line /UbTity set /Cents.. upblast /etc.) CFM 0 70F T.S.P.''(ESP +,Int. Losses) FM ,,MOTOR (HP)' Voltage /Phase Motor Efficiency Type ol VAV Control,. Quantity', of Fans Factory curb Total Weight (less site built curb) Supply .Smoke:, Detector Starters, Disconnects, wiring 110 V. Service Outlet Within 25' Back Draft Damper ET -I GREENHECK GB -21 -20 BATT. RM Centrifugal', Rooftop, 4360 460/3' high N/A 200 by elec. NA REQ. EF -2 GREENHECK GB -140 -3 2nd flr cant. And lobby Centrifugal Rooftop 1480 5/8" 1/3 120 /'1I high, N / 200 by elec. REQ. SF -1,2,3 GREENHECK SBS- 3H48 -75.. Generator intake air Propeller 27550 3/4' 7.5'. 460,./ 3 high on /off: control tie -in ,.w /generator 3i 420 by elec. REQ. Expansion Tank Schedule Tag f basis of design model number service location tank style tank volume (gallons) acceptance (gallons) weight:(Ibs.) 5X -605 Condenser water system Cooling Tower Enclosure''. 11.3 M2000 -014 EXPIRED HYD0ONIC HEAT PUMP SCHEDULE HHP COOL'G MOW / TOT SENS HEAT MBH SUPPLY FAN DaTA CFM: ESP MHP CODE WIR. SUPPLY ELECTRICAL MIN. EER (X'11 PD(6) VOLT /PH MCA CODE UNIT MIN. UNIT EER COP COP! FNl SPEED WEIGHT (LBS) ALTERS (QTY) SIZE NOM - TONS SEISMIC BRACING REQUIRED MANUFACTURER OR EQUAL MODEL / NOT USED NOT USED 16.5 12.9 25.9 0.3 1/8 3.8 10.6 265/1 11.7 I 9.0 "111.1 I 2.64 3.8 high 195 ( 1 ) 1 5 2 2 3 1 ( t 1.5 019 21.6 '' 16.3 1 34.7 0.35 1/3 5.0 15.9 460/3 6.5 9.0 111.7 2.64 3.8 law 206 ,..I (1) 17 :223 x 1 420 024 32.9 25.4':. 47.4 1200.: 0.45 1/2. 7.5 4.7 460/3 ; 8.1... 9.0 12.1 2.64 4.1 .. low (1) 18.x35 x 1 ''.;3 1 186: 036 21.6 16.3' 0.35 1/3 5.0 15.9 460/3 6.5 9.0 11.7 2.64 3.8 be (1) 17 x23 x 1 200 NO 024 21.6 16.3 34.7 0.35.., 1/3 ,.''.. 5.0 15.9' 460/3 6.5 9.0: 11.7 2.64' '206 (1):17x23 x 1 .' NO 52 024 COOLING) CONDITIONS: MANUFACTURER OR EQUAL AND REMARKS: 75 F DB AND 63 F WB EAT., 85 !F EWT AND 95 F LW1 MCQUAY, HORIZONTAL WATER TO AIR HEAT PUMPS MODEL CCH (DESIGN VINTAGE 'C') PROVIDE EMERGENCY POWER TO HHP-1 THRU HHP-7 .. Ey CORPORATION ARCHITECTURE GROUP' -- CONSULTANTS REVISIONS ISSUE DATE EANYJmal Conboctots 017d 5005 Jar ice South P.O.Bon 24567 Seoft Wb. 98124 )phonea (2p6) 762 -2624 5400 AE Colombia ]7Ad PaGmm4 Or. 97118 phone f (�J 33 -6907 PERMIT iSSUIE )2 -l5 -99 A droni ge ad oaten material appeQk g heat aesthete the engird wit repatriated Work of the &ky 0apor�oe and the mane may not deprecated. used used a drbrd without the written concern of the of the Sabey Corporation. FILE: Tartaric improvement for at Intergate West (220) Tukwna internatrortal a)vd. Tukwila, (((4 PROGRESS DATE 10"07-59 PLOT: PROJECT NUMBER: 35340 DRAWN BY: JE. CHECKED BY: Intl. APPROVED 51:: 1 9 2000 . 1 MIT CENTER DRAWING NUMBER: System Description (Tem0.Pressure) Materials (or Equal) Fittings (or Equal) Valves (or Equal) Insulation :. Test Procedure Seismic (besides normal hangers) CW8.R Condenser Water (40TF,50psi) Flu with 20X inhibited propylene 9 2 and under. type L copper 2 -1 /2 and up: Sch. 40 welded Blast Steel A53A ERW 2' and under. Wrought copper solder fRti gs Buttweld A234 grede WPB allowed (any si 2* and under. Nibco threaded boll valve. _ _ 2J4' and up: Nibco LD 2000 Butterfly w /loddng lever Balancing valves: Armstrong circuit setter FOrerglass wish vapor barrier 1' and wider phis short (<12') twandres: W 1 -1/2 - T pipe : 3/4' 2 -1/2' pipe and. up: 1' Outdoor= alum. jacket err test_ to 100 psi for 15 minutes Bracing required for 2ye' and up, except within.. 12. of structure POSER Fuel Oil Piping (70'F, 25 psi) Threaded Sch. 40 Bladc Steel A53A ERW 125/ Black - ..M.I. threaded; FRP.. Nibco threaded ball valve N /R Pressure test to 60 psi for 30 minutes Bracing required for 1' and up, except within It of structure FOSSE Secondary Containment FRP N /R. N/R : Same. as FOS & R SEX Generator Exhaust (1000'F) Sch. 40 Black Steel A53A ERW Buttweld A234 Grade WPB N/R 2 Cpl -St through 1st fir. space out to end of -pipe; loth jacket indoors, metal Octet N/R Bracing required 0 each penetration; allow for expansion NPCW Non - Potable. Cold Water (50'F,50psi) Type L Hard Copper ' Wrought Copper Solder - Fittings 2 and under: Nibco sweat ball valve 2((^ and up: Vic .series 700 Butterfly Indoors: )4' fiberglass. Outdoors: 1' fierglass with Alum.'. Jacket Per 1997 UPC Section 103.5.3 Bracing required for 2r and up. except wlhin 12 of structure POW Potable Cold Water (50TF,50ps) Type L Hard Copper . Wrought Copper Solder Fittings 2' and under: Nibco sweat ball valve' 2r and up: Vic series'. 700 Butterfly '.Indoors: /i' Fiberglass; Outdoors: 1' Fiberglass w/ Alum. Jacket Per 1997 UPC Section 103.53 Bracing required for 2r and up, except within' It of structure PNW Potable Hot Water (t20'F,50psi) Type L Hard Copper Wrought Copper Solder Fittings '.. 2 and under: Nibco sweat ball valve 2r and up: Vic series 700 Butterfly Runouts ;/i' Fiberglass; 2 and under: 1' Fiberglass; Outdoors: 1 ' Fiberglass and add alum. Jacket Per UPC Section 103.5.3 Bracing required for 2r and up, except within 12 of structure PHWR Potable Hot Water Return (120'F,50psi) Type L Hard Copper Wrought Copper . Solder Fittings l and under: Nibco 'sweat ball valve Runoutx ( Fiberglass; 2'' and under: 1' Fiberglass; Outdoors: 1r Pt erglass and add alum. Jacket Per 1997 UPC Section 103.5.3 Bracing required for 2( and '. up, except within 12 of structure W Sanitary and Lab Waste (<140TF,5psi) Below 1st Floor. Cast Iron Soil Pipe, Copper DMN No Hub, S.V. Above 1st Floor: Copper DWV No Hub Soo Wrot Copper DWV N/R N/R Per 1997 UPC Section 712 : Bracing required for 2$ and up, except within 12 of structure V Vent (<I40'F,5psi) Above grade: Cast Iron Soil Pipe, Na Hub, S.V. Below grade: sch. 40 PVC No Hub Soil N/R N/R Per 1997 UPC Section 712 Bracing required for lye' and up, except within 12 of structure Piping Specification M2000 -014 \iVc PROGRESS DATE: i CORPORATION EY ARCHITECTURE GROUP CONSULTANTS Mechanical Contractors and Eg inlets 5005 34 Ave Saudi P.O.Bor 24567 Swift 92 98124 phone l 1 762 -2624 5400 NE Colombia . Blvd Portland, Or. 87218 phone f (5 331 _efEtlIT is& p -s -99 REVISIONS ISSUE DATE N- dmsin9e -a and eriin material herein conelitute the anginal and unpublished vast of used and the some mcry without written danced of the Sebsy CorpmaUan. FILE: Tenant': improvement' for at lntereate West 1220! Tukwila International Blvd. Tukwila, (((4 DRAWING TITLE: Mf -DT -99 5PECIFic04T1cN5 RECEIVED CITY OF 7UKWItA JAN 1 9 2000 DRAWING NUMBER: PLOT: PROJECT: NUMBER: 35340 DRAWN BY: ! J.E. CHECKED BY: DI'L APPROVED BY 3`UP TO FD(TYP.) HD ABOVE Oki FCO 01 / UP `31Y BELOW GRADE ELEC. RM. MECH SHELL CONTRACTOR SHALL RELOCATE ALL 'PLUMBING F1PES FROM THIS AREA & REROUTE AS REQUIRED. (D) a (FD) P3.02 NOTE: ALL P -TRAPS SERVING I FLOOR DRAINS FT-I (TYP OF 10) SHALL BE HEAT TRACED. GARAGE LEVEL P1 PLUMBING PLAN SCALE: 1 /8' = 7.5 j M2000 -014 8, MAINTAIN .7 10`CLR\ \ 4• PIPING SHALL BE INSTALLED. HIGH AS POSSIBLE. GRADE PIPE 1 /8' /FT. EMMA MEM CONNECT TO EXIST BELOW =MN FLOOR 31Y (TY)'< 1`0W DN..'CONNECT TO EXIST. 2 MAIN. PROVIDE REDUCED PRESSURE BACKFLOWI DEVICE CORPORMION ARCHITECTURE GROUP CONSULTANTS REVISIONS ISSUE DATE Mechanical Contactors and Engem= 500.5 3N An South P.OBar 24567 &attq Wm 98124 '.. lac (206.) 0 762-2624 5681 NE Coranbria E8I Port/md, Orr. 97218 phone l :331-6905 PERMIT ISSUE 21152 N - &wi gs and with material appsaig herein aaerbUde the Wind ad. wahrehed earl[ at the Sabel and the sane may not be cWpiicated, used a without the written canoeist at the Sabel Corporation. Tenant Improvement for at Intergate West 12201 Tukwila international Blvd. Tukwila, 014 DRAWING TITLE. G,4R4GELEVEL PI PLUMSMG PLAN PROGRESS DATE FILE: 10 -D7 -99 PLOT: PROJECT NUMBER: 35340 DRAWN BY: J.E. CHECKED BY: DM. APPROVED BY RECEIVED CITY OF TUK 2000 JAN 1 9 2000 '3ER I.I I PSy;NL` Ker IIII_I..II 2'VUP&DN un� 1 /2 UP P3.1A FIRST FLOOR PLAN SCALE 1/8 = t O M2000 -014 SF EY CORPORATION ARCHITECTURE GROUP CONSULTANTS REVISIONS ISSUE DATE a D r ti PROGRESS DATE FILE: instry Yedmied Caabatms and E.O.P. 5005 3rdlee South P.affor 24567 Seattle Nix 98124 phone lac J 762.2624 5400 445 Colombia BiM Por8an4 0/ 27218 phon f e ar PERMIT 1551E N= dmaige -and =ten matmid apgmbg (rein cad0iubr the crigbad and nep18Geh.d sac of the Saby and the some mcy not be dogmatist wed art= ..Ulaut: wr itten cement a the Sabey corporation. Tenant improvement Por 'ZAMA at lnterrate West 12201 Tukwila International Blvd. Tukwila; WA 089WIN9 TIME: FIRST FLOOR PLAN LN2EgELG10R PLUPM4 IO -DT -99 DRAWING NUMBER: PLOT: PROJECT NUMBER: 35349 I DRAWN BY: JE CHECKED BY: ' Pit APPROVED BY: .i...... R R ED CITY OF NKWItA JAN192000 1 1 /YCW DN TO CRU 3/4' CONDENSATE ORAIN. 4 DN lc UP TERMINATE IN JAN.SINK 1 "CW DN TO RAISED FLOOR PLENUM 2V - ON H -- a_ - a a a _ a _ ; 111 NI NI II .gi ENNIIMilli 1 l* I I i N N ' ®® t" RPBP 1 /2'CWVALVE 2' UP TO FD -1 ABOVE ^2Y UPk21Y 214 UP 214 IN FURRED WALL r2'W DN j { - ARCHITECTURE GROUP CONSULTANTS REVISIONS ISSUE DATE PROGRESS DATE FILE: IlaNard Engine= 5075 3rd Ave Smith P.as 24567 Seat* ,Ida 98124 1 phone (2) 4 2624 5407 AC Cokanbio BAd Portland, Or 97218 phone (503) 331-6983 EY -ATKA 'miry PERMIT' 12-15 -99 N - 6afr s and sake ned work a the a an the d a e s ome ay not be * of the S e d and the some wri tten cone* of the &be ar eithout the ssdh anewd SaMy. Cooperation. Tenant improvement l for at lntergate West 12201 Tukwila International Blvd. Tukwila, 6664 DRAWING 1 M - E: FIRST FLOOR PLAN OVERHEAD PL111BMG FIRST FLOOR PLAN - OVERHEAD PLUMBING SCALE 1/8 _ 1' =0 DRAWING NUMBER Mf-DT -99 PLOT: PROJECT NUMBER: 35340 DRAWN BY ,LE CHECKED BY: '' DPI 6916OVr7A BY: �A - ; 1 CRY - 7 19 2000 I 9 , / -2Y DN 2Y UP & TERMINATEAT -.ROOF 2'W DN ..._. /_21Y RUN IN WALL ABOVE FLOOR 1 ".CW CONNECT TO EXISTING SERVICE'; LOCATION IN ',',PLUMBING WPIL, -y CW. CALVE & CAP.. --_ 3Y CONNECT TO EXIST IN TOI(ET ROOM CEILING 2 V' ON 2Y DN 2Y DN 3Y DN Qo Y,} N-2' FD -1 ❑o 2 FD -1 1 DRAIN TERMINATE -- 6 ABOVEISERVICE SINK c �3Y "-2" FD -1 "-2• FD -1 \ 2• FD-1 N-2" FD- NOTE PROVIDE TENPORNGY CAP & SEAL FOR FLOOR BRAINS ON THIS FLOOR.(TYP. OF 9) M2000 -014 ciAnuKE ll, JAN 1 9 2000 EY CORPORATION ARCHITECTURE GROUP CONSULTANTS DRAWING TITLE PROGRESS DATE: FILE: PLOT: Mechanical 0/ Engineers 5005 3rd Are South P.O.Ba - 24567 SeatBq Na 98124 phone / �) 7622624 5400 NE Cokant is Ellid Portland, Oh. 07218 phone (504 331-6903 / (565)- 3 -6830 PERMIT 1S5i E REVISIONS ISSUE DATE dry 91 dme6ge and sultan material appea6p heein aneWL the aighd and unputiehed eta ai the Sahey and the some may not b dupgwhd, used ar Oapar6on without the written cans.* d.tla Salty Tenant Improvement For at intergate West 12201 Tukwila International Blvd. Tukwila, WA 1 SECOND FLOOR PLAN - PLUMBING P3.2 SCALE: 1/8" = I' -0" DRAWING NUMBER: APPROVED BY SECOND FLOOR PLAN UNDERFLOOR PLUMESI r 1® -07 -99 PROJECT NUMBER: 35340 DRAWN CHECKED BY : rtrt P3 2 PLUMBING FIXTURE SCHEDULE ITEM MODEL 8-1 COFFEE SINK FIXTURE : FAUCET: STRAINER *TRAP: 'SUPPLIES: ELKAY PSR -1918, STAINLESS STEEL, COUNTER MOUNTED, 12X12X7 BOWL DIM... ZURN. KL11481PS, SWING SPOUT, LEVER HANDLE, CHROME PLATED CRUMB, CUP STRAINER,: TAILPIECE WITH DISHWASHER CONNECDON. R364, 1 -I /2" X 1 -1/2" 17 GAUGE, CHROME PLATED LSD 0901K FD-1 FLOOR DRAIN MODEL: ZURN - Z-415. CAST IRON BODY WITH TYPE. "I' RESCESSED STRAINER. TRAP PRIMER: AS REQUIRE) PER CODE RECESSED CONCRETE STRAINER / FLOOR 4 MAX SIZE CORE DRILL THRU CONC. PLANK DRAIN BODY FLOOR DRAIN (FD) NOT TO SCALE / TOPPING 4 SLAB " a PRECAST COHC. PLANK 8" ZURN Z-400 CM "IYPEP STRAINER (OR EQUIVALENT) CORE DRILL THRU HOLLOW SECTION WHICH HAS NO PT CABLE IN IC SUBMIT STOP DRAWING OF ALL FLOOR PENETRATIONS TO STRUCTURAL ENGINEER FOR APPROVAL. PRIOR TO CORE DRIWNG. AIR GAP' TITLING_ IN WALL WITH ACCESS PANEL P -TR P ` FLOOR WALL CLEAN slur PROVIDE DRAIN PAN .... UNDER SINK !. DISHWASHER WATER HEATER DETAIL NOT TO SCALE ELECTRIC WATER HEATER IN CLG WITH SBSMIC BRACING DRIP PAN WITH DRAIN CIL -/ 1/2" H&CW IN WALL ELECTRIC WATER HEATER SCHEDULE LOCATION/ SERNCE COffEE SINK AND OLSLNIASIIFR DEC. RJR 3 106 RIDD EFi CAN 0'100 DEGREE RISE VOLTAGE/ PHASE BASIS OF DESIGN AO.S1BIH. DEL -20 '.. 20 GAL DAME EXPIRED CORPORATION ARCHITECTURE GROUP CONSULTANTS REVISIONS ISSUE DATE DRAWING JITLE: FILE: Mechanical Contractors and Engineers 3n1 Ave South P.O.Bar 21567 Sedgy N6.'. 98124 phone l) 762 -2624 5400 AE Columbia Blvd Pam OF. 87218 phone (sas) dry PERMIT ISSUE ' L2 -15 -99 N darlings ad with mo0rid appvig horde =Mute the original ad aputidwd: wok of tht Sabo" CaDaa6m and tha. sans may not be dupused oated, used or without the mlten cancan* of the &bey Corporation. Tenant Improvement for at Intergate West 12201 Tukwila international BIvd. Tukwila, W4 PROGRESS DATE .' Ip.07_99 DRAWING NUMBER: RECEIVED CIT1',OF NKWILA JAN 1 9 2000 PLOT: PROJECT NUMBER: 35340 DRAWN BY: JR. CHECKED BY: RJ"L APPROVED BY 41 RETAILS 4 SCNERULES