Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M2000-217 - BOEING #9-04 TO #9-52
M2000 -217 Boeing #9 -04 9725 E Marginal Wy S Address: 9725 EAST MARGINAL WY S Suite: Tenant: BOEING #9.04 TO #9 -52 Type: B -MECH Parcel #: 000340 -0018 Signature: CITY OF TUKWILA * * *** * * * * *** *** *•k #•k* *** * * *•* **** * **** k*•k h A k k k k * *** *Ark ** ** kA*•k* k k A* *•k * *•k *-k•** Permit Conditions: 1. Readily accessible access to roof mounted equipment is required. . Any exposed insulations backing material shall have a Flame Spread Rating of 25 or less. and material shall bear identi- fication showing the fire performance rating thereof. Plumbing permits shall be obtained through the Seattle -King County Department of Public Health, Plumbing will be inspected by that agency, including all gas piping (296 - 4722)4 `BTU MAXIMUM .ALLOWED PER 1997 WASHINGTON STATE ENERGY CODE. No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. All permits, inspection records, and approved plans shall, be evallible at the job site prior to the start of any con- struction. These documents are to be maintained and avail— able until final inspection approval is granted. Al l :. construction to be done in conformance with approved plane and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), end Washington State Energy Code (1997 Edition). 8. Vali d i ty. of Permit. The issuance of a permit or approval 0 plans, specifications, and computations shall not be con- strUed to be a permit for, or an approval of, any violation of any of the p r o v i s i o n s of the building code or of any other ordinance of the jurisdiction. No permit presuming to give :.authority to violate or cancel the provisions of this code shall be valid. . Manufacturers installation instructions required on site for the ,bu 1 1 d I ny inspectors review. 1 hereby certify that h have read these conditions and will :comply with them as outlined. All provisions of law and ordinances governing this :work will be'oompl ied with,' whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the p r o v i s i o n s of any other work or 1 oaa 1 laws regulating construction p of work. Print Name: Permit No: M2000 -217 Status: ISSUED Aaolled: 09 /12 /2000 Issued: 12/13/2000 Date: J;46 /, ig City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M2000 -217 Type: B -MECH Category: NRES TENANT OWNER CONTACT CONTRACTOR UMC Edition: 1997 Permit Center Signature:___ - - - MECHANICAL PERMIT Address: 9725 EAST MARGINAL WY S Location: Parcel #: 000340 -0018 Contractor License No: BOEINC*294ML BOEING #9 -04 TO #9 -52 9725 EAST MARGINAL WY S, TUKWILA, WA 98188 BOEING PO BOX 3707 - M/S 1F -09, SEATTLE WA 98124 JOHN MURDOCH PO BOX 3999 M/C 89 -15, SEATTLE, WA 98124 BOEING COMPANY PO BOX 3707, M/S IF -09, SEATTLE, WA 98124 ************************************,******* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: PLEASE REFER TO CONSTRUCTION NOTES. REMOVE & REPLACE EQUIPMENT, REMOVE & ADD DIFFUSERS. ******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** horized Signature Date Valuation: Total Permit Fee: Status: ISSUED Issued: 12/13/2000 Expires: 06/11/2001 Phone: Date: 01/.4 t9G7 (206) 431 -3670 Phone: 253- 773 -0444 30,000.00 187.13 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this bu lding p Print Name: Title: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Project Name/Tenant ,qb 4 61-66440 70 q _ J Value of 1∎4 AVV Site Address : vzo 6A 38 State/ZZip � i Tax Parc D rb Property Owner: / fr ii4lG ! *owl Phone: (Zr � ,-Ovy S d / AO e'!5 &N.17.6 04.1 Fax : 7'73-.07q32 Contractor: 7 . 5 ♦ Phone: ( ) Street Address: City State/Zip: Fax 11: ( ) Contact Persj____-- oo n / Phone: ( ) 743,alif./ '. eeAd bs/e 1 1 M/y 15 5a /t Cit / tey ‘ 31_1_111_ 8 1 .0_ 211 5 . Fax ft: (ZO) . 773_ o CITY OF T U 'WiLA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 ,�AC1� �'kvD 'DiFi�u,S�es IMO TAFF USE ONLY Project Number: Permit Number: ZpGt� -ZI'! Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. MECHANICAL PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT HY APPLICANT) Description of work to be done (please be specific): t A 1 ' ' "C� C4 4600/GT/0' eat gett4V Ieekx Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is Issued OR submit Form H.4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal, 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PER JURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Signature: Wir.:#117/ OWN %. :dr;ss: ►r / a ) J RDOci 44 c / C" Fax N: ( /• l ill �!ll. 'j . E i OR AUTH • K ED AGENT: Date appl' tion accepte I 1 ,' / / ~ 11/2/99 Hoch pamitdoc Date applica�'on expires: Or S;r 11 -- 1 Expiration of Plan Review • Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 100 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition), No application shall be extended more than once, Application to q by: (initials) ✓ Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal ve 11/)/99 mtxcpa+tdac NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. RESIDENTIAL: Two complete sets of attachments required with application submittal .Submittal Requirements New Single Family Residence Heat loss calculations or Form H -6. Equipment specifications, Chan a out or replacement of existing mechanical equipment Narrative of work to be done Includin: modification to duct work. Installation of Gas Fire - lace Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney Is in safe condition. NOTE: Water heaters and vents are included in tho Uniform Mechanical Code = please include any water heaters or vents being installed or replaced. *_ * * * * * ** ilfr *# * * *' * * ** ** * ** * *** * ** * * * * * ** *fir * * ** * *** * ** t.A I :uF� i'ux r�.N. NA ( IRAN9Mtr i * * * * * * ** * * * * * * * * * * * * * ** * *** *A **** * * **k*** ** ***fie * ** UAN3M1 r Number: 89800406 Amount: 187.13 12 /13 /00 13:44 torment Method n CASH Notations MIRY TALLER In i t s ILO W a r ice- ....- - - i - Y an a w w - Y i i. Psivnwnt #i************* Account :count Cade OOO/345.830 000/322.100 Permi Nos m2000-217 lvoes S -FILCH MECHANICAL PEKMI1 Parce Nos 000340 -0018 Ito . Addritosu 9725 EAST MARGINAL WY �S rata' Foods 187.13 187.13 lotsi ALL Pmtst 107.13 Oalanams .00 **********.**** A*** * * * * * * * *** * * * * *** ** * * * * * * * * * * Ueucr of tan Amouint PLAN CHECK - NCINHES 37.43 MECHANICAL - NONREB 149.70 .. • TOT 6dditional Co c: PERMIT NO.: MECHANICAL PERMIT APPLICATIONS INSPECTIONS ❑ 00002 Pre - construction ❑ 00050 WSEC Residential ❑ 00060 WA Ventilation/Indoor AQC ❑ 00610 Chimney Installation/All Types 0 00700 Framing 01030 Woodstove 01090 Smoke Detector Shut Off 01100 Rough -in Mechanical 01101 Mechanical Equipment/Controls 01102 Mechanical Pip/Duct Insul ❑ 01105 Underground Mech Rough -in 01115 Motor Inspection 1400 Fire Final 01800 Final Mechanical 04015 Special -Smoke Control System CONDITIONS 000 1 No changes to plans unless approved by Bldg Div 0014 Readily accessible access to roof mounted equipment 0016 Exposed insulation backing material 0019 All construction to be done in conformance w /approved plans 0002 Plumbing permits shall be obtained through King Co 0027 Validity of Permit 0003 Electrical permits obtained through L & I 0036 Manufacturers Installation instructions required on site 7t b "BTU maximum allowed par 1997 WA State Energy Code" 0041 Ventilation is required for all new rooms & spaces "Fuel burning appliances "Appliances, which generate...." "Water heater shall be anchored,,.." TENANT NAME FEES 'k9 -o, ►t9 -s2 Basic Fee (Y/N) Supplemental Fee (Y/N) Plan Check Fee (Y/N) Furnace/Burner • to 100,000 BTU (qty) Over 100,000 BTU (qty) Floor Furnace (qty) Suspended/WalfFioor- mounted Heater (qty) Appliance Vent (qty) Heating/Refrig/Cooling Unit/System (qty) Boller /Compressor to 3 HP/ 100,000 BTU (qty) to 15 HP /500,000 BTU (qty) to 30 HP /1,000,000 BTU (qty) to SO HP/1,750,000 BTU (qry) over SO HP /1,750,000 BTU (qry) Air Handling Unit to 10,000 cfm (qty) over 10,000 ct% (qty) Evaporative Cooler (qty) Ventilation Fon (city) Ventilation System (qty) Hood (qty) Incinerator — Domestic (qty) Incinerator — Comm/ind (qty) Other Mechanical Equipment (qty) Other Mechanical Fee (enter SS) Add'l Fees — Work w/o Permit (Y/N) Imp Outside Normal Hours (hrs) Reinspections (hrs) Miscellaneous inspections (hrs) Add'l Plan Review (hrs) Plan Reviewer: Date: i 1 Permit Tech: Date:, 12 "1' Project: Lb f r Typ f Inspec on: (: dress. Gr( trtk Da t c lied: C' Special instructions: /:6*Ct Date anted: .m. • . 111.3 -- 1 "" 0 C 19 CO ENTSt Receipt No:* INSPE RECORD Retain a copy with Oermit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 1.i. Approved per applicable codes. Date: Date: PERMIT NO. (206)431 -3670 E3 Corrections required prior to approval. Inspector if irroriummeramarsw $47.00 REINSFECTION FEE REQUIRED, Prior to inspection, fee must be paid at 6300 Seuthcenter Blvd., Suite 100. Call to schedule reins'ection. A . • 1908 Project Name J%ddress V 1 a, Retain current inspection schedule Needs shift inspection - Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Authorized Si nature INALAPP . FRM City of Tukwila Fire Department Approved without correction notice Approved with correction notice issued / :, itJ /J TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Rev, 2/19/98 Suite # T.F.D. Form F.P. 85 Steven M. Mullet, Mayor Thomas P Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwla, Washington 98188 • Phone: 206.575.4404 • Fax: 206.5754439 COMMENTSt 1., a I Pf \ .----..., MIC Special instructions: / cjry t . / 9..t4A-i ID 6 Da ante ' 7 ,Y CI _..... 1117# 2_1_,.. R ter: r 1 Ph'one: t.. -spot Project: 44 _ , Pi " i v1 , r i - i‘ L I 1 0 14 1-52 Type of Inspettiop: Plc( i Addres s: S 2 E. Wirt NI IA `) Date :lied /4 0 Special instructions: / cjry t . / 9..t4A-i ID 6 Da ante ' 7 ,Y CI _..... 1117# 2_1_,.. R ter: r 1 Ph'one: t.. -spot Approved per applicable codes. IttW -:;44 , i4W d96 0 INSPICTION REC06 Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 ?4,01.1,4r. 1 • PERMIT NO. (206)431-3670 '2 C 7 ifr/- tr °t r( ree ion require pr or to approval, O $47.00 REINSPECTION FEE REQUIRED, Prior to inspection, fee must be paid at 6300 Southcenter 8Ivd Suite 100. Call to schedule reins ection. P oject: • • ‘..:..:4 AL.:4 .. ,.,, T •e of I WO : Address: • d• 4-- ti .. * , .. Date cal ed: .4110 Special instructions: 9 r 7 '''• Date wante • 0 . Requ stet: . * , ii , P o e: .. 0 CO MEWS: O $47.0 INSPECTION FE at 6300 Southcenter Blvd., Receipt No: • Date: Impactor: • INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA *pa Approved per applicable codes. PERMIT NO. (206)431-367 7r** Corrections required prior to approval. QUIRED. Prior to inspection, fee must be paid its 100. Call to schedule reinsewiE. Date: .XL Original Plan Submittal MEP_ARTMEN_TS: Builreg Division zi l 12/1190 Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ Complete Comments: wuaiUtx)C x+w fPPROVAj Q OR$ECTIONS: (ten days) Approved El Approved with Conditions REVIEWER'S INITIALS: E.} CO iE DETERMINATION: Approved Approved with Conditions REVIEWER'S INITIALS: PLAWJI&9?YFING SLIP ACTIVITY NUMBER: M2000 -21 DATE: 942 -2000 PROJECT NAME: BOEING #9 -04 TO #9 - BLDG. SITE ADDRESS: AZZa. EAST MAR GINAL WY S Response to incomplete Letter # Response to Correction Letter # _Revision # After Permit Is Issued Fire Prevention JJ Planning Division Muir j. is-vP Structural TUES /TNURS ROUTI G: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: DATE: Permit Coordinator DUE DATE: 9114 -2000 Not Applicable ❑ DUE DATE„ 10- 12 -200Q Not Approved (attach comments) ❑ DUE DATE Not Approved (attach comments) ❑ DATE: City of Tukwila Steven M. Mullet, Mayor Fire Department Thomas E Keefe, Fire Chief Fire Department Review Control #M2000 -217 (510) September 18, 2000 Re: Boeing Building #9 -04 to #9 -52 - 9725 East Marginal Way South Dear Sir: The attached set of mechanical plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 1. One or more portable fire extinguishers having a rating of not less than 20 -B shall be located not less than 10 feet (3048 mm) or more than SO feet (15240 mm) from any Class I or 1I liquid storage area located outside of a liquid storage room. (UFC 7902.5.11.5.2) Portable fire extinguishers shall be securely installed on the hanger or in the bracket supplied, placed in cabinets or wall recesses. The hanger or bracket shall be securely and properly anchored to the mounting surface in accordance with the manufacturer's instructions. The extinguisher shall be installed so that the top of the extinguisher is not more than 5 feet above the the and the clearance between the bottom of the extinguisher and the floor shall not be less than 4 inches. Extinguishers shall be located so as to be in plain view (if at all possible), or if not in lain view, they shall be identified with a sin stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC Standard 10 -1) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206.575.4404 • Fax: 206•S7S -4439 City of Tukwila Fire Department Page number 2 Duct smoke detectors shall be capable of being reset from the alarm panes.. (City Ordinance #1900) Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of Steven M. Mullet, Mayor Thomas P. Keefe, Fire Chief Fire extinguishers require monthly and yearly The must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. (NFPA 10, 4 -3, 4 -4 and 4 -4.3) Every six years, dry chemical and halon type fire extinguishers shall be emptied and subjected to the applicable recharge procedures. (NFPA 10, 4 -4.1) If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 2. H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1900) H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions, (UMC 608) Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2)) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206.575.4404 • Fax: 206.575.4439 City of Tukwila Page number 3 such condition or violation. Yours truly, cc: TFD file ncd '5t The Tukwila Fire Prevention Bureau Steven M Mullet, Mayor Fire Department Thomas R Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-5754404 • Fax: 206-575-4439 FROM 1 80E Y r 1G TAX rag 463 1 IIti4 =,Ad1.1U Iii i$?Jl1 DEPARTMENT OP LABOR AND INDUSTRIES L. 2056554682 REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL 20006.01 -27 10151 #058 15.02/02 REGIS ?. # EXP. DATE CCO1. BOEINC*294ML 01/01/2001 EFFECTIVE DATE 07/13/1971 BOEING COMPANY, THE PO BOX 3707 MAIL STOP 1F -09 SEATTLE WA 98124 -2207 r)eiui h MW I)41*.$) Coil1 w �- •��� REGISTERED AS PROVIDED BY LAW AS CONS? Corm GENERAL MOIST. # EXP. DATE CCO1 BOEINC+294ML 01/01/2001 EF?ECTIVZ DATE 07/13/1971 BOEING COMPANY. THE PO BOX 3707 MAIL STOP IF -09 SEATTLE WA 98124-2207 Swouno Ih3ukM by DNl'ART1vIr:NT (.)N LADOR A.NU I uIl� "I'at�us Please Remove And Sign Identification Card Before Placing In Billfold VICINITY MAP REMODEL BREAKROOM 9 -52.1 9 -04 OFFLOAD REVISION PROJECT SITE 7 -127 KING COUNTY AIRPORT f �; E FROM SEATTLE- TACOMA AIRPORT FROM DOWNTOWN SEATTLE 80 99 EAST M9DDNAL WAY CORPORATE PARK J1794618 -00 Js 100002 -01 BY GMM MRM DEVELOPMENTAL CENTER APPROVED 900 N', v b� 1 N :, r \ I 599 TUKWILA 0 FROM KENT & AUBURN DATE 12.16.99 08.14.00 NG M AflRCRAFT EXIT NO SCALE 157 95C BUILDING ADDRESS: - 9725 EAST MARGINAL WAY SOUTH SEATTLE, WASHINGTON E090N 9 -52 BUILDING LOCATION BUGLDNG 9-52 9-04 OFFLOAD J#900002-03 El G V LOP E TAL N E AREA MAP APPROVED C. NO SCALE CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. CHECK BOX 1. VERIFY ALL DIMENSIONS AND CONNECTIONS BEFORE ANY WORK. 2. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 3. COORDINATE WORK WITH OTHER CRAFTS. 4. RETURN THIS SAME SET TO JOHN MURRDOCK AT BUILDING 9 -51.2 COLUMN M /2, AFTER COMPLETION OF THIS CONSTRUCTION. PROJECT CHECKLIST ® ROOMS LABELED PER OCCUPANCY PER U.B.C. TABLE 10 -A. BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION. ID NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE: ❑ 1. TENANT IMPROVEMENT (STRUCTURAL): ❑ 5 SETS OF ARCHITECTURAL DRAWINGS ❑ 5 SETS OF STRUCTURAL DRAWINGS ❑ 5 SETS OF STANDARD DETAILS ❑ 5 SETS OF ENGINEERING CALCULATIONS ❑ 5 SETS OF ENERGY CALCULATIONS ❑ 5 SETS OF CONSTRUCTION SPECIFICATIONS 0 ,..firmezevc. GENERAL NOTES THESE DRAWINGS CONFORM TO THE 1997 U.B.C., U.F.C., U.P.C., AND THE WAG 51 -20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES AND COMPLIANCE WITH CITY OF TUKWILA ZONING. ® 2. TENANT IMPROVEMENT (NON- STRUCTURAL): ® 4 SETS OF ARCHITECTURAL DRAWINGS ❑ 4 SETS OF STANDARD DETAILS ❑ 4 SETS OF ENERGY CALCULATIONS ❑ 4 SETS OF CONSTRUCTION SPECIFICATIONS ❑ 3. MECHANICAL, 4 COMPLETE SETS. ❑ 4. FIRE PROTECTION /SPRINKLERS, 3 COMPLETE SETS. ® BRIEF PROJECT NARRATIVE: REMOVE A PAINT BOOTH AND THE GCU ADMINISTRATIVE OFFICES INSTALL THE HAZ. MAT. STORAGE CELLS AND EQUIPMENT INSTALL A 13' X 14' MEZZANINE ADDITION INSTALL A 14' X 66' TRAILER FOR THE HAZ. MAT OFFICES. I72cc� Zl ACCEPTABILITY THIS DESIGN AND /ON SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE C I DARTED CHECKED APPROVED APPROVED SUBTITLE SHEET NO. DRAWING NO. SYST MI 9-52-5/11 TITLE SHEET M1A 9- 52 -1MA EQUIPMENT LIST SCHEDULE IM6OR 9- 52 -1M6OR PIPING DEMO PLAN 0M110 9- 52- OM110 _PLUMBING PLAN 1M110 9- 52 -_1M110 FIRST FLOOR PIPING PLAN 1M10R 9- 52 -1M1OR HVAC DEMO 1M10 9- 52 -1M10 HVAC FLOOR PLAN RFM10 9- 52 -RFM10 HVAC ROOF PLAN RFM210 9- 52- RFM210 ROOF PIPING PLAN M300 9- 52 -M300, CONTROLS DRAWING M500 9-52- kiTiOr SECTIONS AND DETAILS M501 9- 52 -M501 DETAILS 9- 52 -M502 DETAILS M504 '9- 52 -M504 DETAILS M505 9 -52 -54535 DETAILS LAND USE CODE BUILDING CODES OCCUPANCY GROUPS CONSTRUCTION TYPE FLOOR AREAS: BUILDING FOOTPRINT BUILDING GROSS FIRST FLOOR MEZZANINE BUILDING HEIGHT STORIES OCCUPANT LOAD: HANDICAPPED REQUIREMENTS SEISMIC ZONE DESIGN LOADS: ROOF - SNOW ROOF - LIVE FLOOR - OFFICE (LIVE) FLOOR - DEAD FLOOR - MECHANICAL & STORAGE FLOOR - STAIRS AND CORRIDORS WIND LOADING FIRE PROTECTION SPRINKLER SYSTEMS 4 0 V So q 1pDM DFG \'v ta,o STANDBY /EMERGENCY POWER TITLE SHEET BUILDING 9 -52 DRAWING INDEX SHEET TITLE CODE SUMMARY MS TUKWILA 1997 UBC, WASHINGTON STATE ENERGY CODE, WASHINGTON STATE BARRIER FREE CODE AND ADDITIONS PER CITY OF TUKWILA GROUP B - OFFICE GROUP H2 & H3 FLAMMABLE DISPENSING AND STORAGE TYPE V -1HR OCC JPANCY SEPARATIONS: B tq- -H3 =. THR-&-B-to-H2=-2HR- Fr' E: Ca 'Y 6,897 S.F. 7,477 S.F. 6,897 S.F. 580 S.F. 19 Fr. B =3,600/100= 36 OCCUPANTS H= 3,697/300= 11 OCCUPANTS BARRIER FREE 3 25 PSF 20 PSF 150 PSF 20 PSF (PARTITION) 125 PSF 150 PSF By Date CURRENT BENSON J #100002 - 01 SHEET JOB NO. DWG NO. REVISION NO. B A ORIG ORIG A A A ._ DATE 08.21 _00 08.21.00 08.21.00 08.21.00 08.21.00 08.21.00 08.21.00 08.21.00 08.21.00 08.21.00 08 _21.00 02.15.97 08.21.00 08.21.00 08.21.00 i under: and that 1. - .. Hall Check aopie, I3 aTe sottiect o o . ana cri313cir,o ena .3rtanival of plans duos not authcarze the Vio:enon of t cry a dcpted code or 'ordinance. Receipt of Ct n- I . I is copy of approved pans ackno,I dJad. ), 0� Mr; ; Ye TI, REQUIRED FOR: 0 MECHANICAL ELECTRICAL � ( � D i LUMB(NG 1 GAS PIPING 80 MPH, EXPOSURE C CITY OF TUKWILA A MANUAL FIRE ALARM SYSTE6 WI OINILIVINGDNOTJRIDATI r N IN BOTH THE H OCCP. & THE OFFICE AREAS. SPRINKLER WATER FLOW WILL BE TIED IN TO THE BUILDING ALARM & HVAC DUCT DETECTORS WILL REPORT AS A SUPERVISORY. (ADT MONITOR- SUPERVISORY) THE FLAMMABLE LIQUID STORAGE (H3) & DISPENSING AREAS (1-12) WILL REQUIRE A SPRINKLER DENSITY OF.38 GPM OVER THE CELL AREAS. THE SPRINKLER DENSITY FOR THE ADJACENT B OCCP. M AY BE MODIFIED TO A .17 GPM /3000SF. THE VOID SPACE THAT WILL BE CREATED BY THE NEW RATED CEILING WILL REQUIRE SPRINKLERS ON AN ORDINARY HAZARD BASIS. Nil 1 SYMBOL PER STANDBY POWER WILL BE REQUIRED AND EMERGENCY POWER VIA BATTERIES WILL BE PROVIDED FOR THE LIFE SAFETY SYSTEMS (EXIT SIGNS, ALARM PANEL, ETC,) UBC 307.2.6 & UFC 8004.1.6 DATE COMP NO. 08.14.00 IT CENTS EQUIPMENT LIST SCHEDULE DESIGNATION LOCATION DESCRIPTION HP VOLT RPM CFM Sp GPM BTU /HR MAKE /MODEL REMARKS EF -1 REST ROOMS ROOF EXHAUST 1/12 115 1140 806/2 _ - GREENHECK CUE -10 -B DUCT MOUNTED EF -2 FLAMMABLE STORAGE ROOF EXHAUST 1/4 115 1120 786 25„ - - _ G ENHECK CUBE -10 -4 EXPLOSION PROOF_ _ - H3 AREA ROOF XHAUST ROOF EXHAUST 2" 1 1/2" 1725 1360 .62 37900 "JOSAM" C.I. SERIES 3000 -A ® LAVATORY GREENHECK CUBE -120 -3 CLASS 1 DMSION 1 * OR AND DISCONNECTv _ PAINT BOOTH 2 7= - - BLEEKER BROS. BELT TOTALLY ENCLOSED FAN NON - SPARKING EF -5 H2 AREA ROOF EXHAUST 1/4 115 1725 1200 _ 1/2" GREENHECK CUBE -120 -4 CLASS 1 DMSION 1 MOTOR AND DISCONNECT EF -6 TOXIC HEALTH AREA ROOF EXHAUST 1/8 115 1550 450 - 2" GREENHECK CUE -95 -D - f EF -7 OIL DISPENSING AREA ROOF EXHAUST 1/15 115 1550 250 %2„ - GREENHECK CUE -90 -D r EF -8 `EF -9 ACIDS, BASES AREA ROOF EXHAUST 1/15 115 1550 250/ _ GREENHECK CUE -90 -D KITTING AREA UTILITY EXHAUST Mall 1550 16002" _ PACE U -15F RELOCATED OCATED FROM 9 -04 BUILDING PB -2 P81AO2A SPRAY ROOM _�� PAINT BOOTH 1111111601111111111111 - AS SHOWN - - �_ - -� -.�- -- -� ��-- SLEEKER BROS. -- EG -1 EF -1 & EF -2 EXHAUST GRILLE ENVIRONMENTAL AIR PRODUCTS MODEL E -5 1/2" AL SQUARE GRID WH - 1 REST ROOM OVERHEAD WATER HEATER 208 - - - 30717 AMERICAN ER -42 -D 4500 WATT ELEMENT UPPER AND LOWER UH -2 SPRAY ROOM UNIT HEATER VIM 450 320001„ 18000 CF /HR 180000 WEATHER -RITE, MODEL 224 DIRECT FIRED N. GAS FIXED DISCHARGE MAU -1 H2 AREA ROOFTOP UNIT 1560/ 2.00 _ 125000 J GAYLORD MODEL CSU -A9 -7A ROOF TOP UtvIT INDIRECT FIRED N. GAS /DX COO LING, SS HEAT EXCHANGER 2 POSITION OSA DAMPER, 2 STAGE GAS HEAT, SPARK IGNITION MAU -2 H3 AREA ROOFTOP UNIT • : 1000 _ 100000 GAYLORD MODEL CSU -A9 -4A ROOF TOP UNIT INDIRECT FIRED N. GAS /DX COOLING, SS HEAT EXCHANGER 2 POSITION OSA DAMPER, 2 STAGE GAS HEAT, SPARK IGNITION MAU - -3 KITTING ROOFTOP UNIT ROOFTOP UNIT • 480 1600 ' 12.00" - 125000 GAYLORD MODEL CSU -A9 -7A ROOF TOP UNIT INDIRECT FIRED N. GAS /DX COOLING, SS HEAT EXCHANGER 2 POSITION OSA DAMPER, 2 TAGS GAS HEAT, SPARK I NITION AHU-5 OFFICE /CONFERENCE RM 5 480 850 ,200 56„ _ . 320000 AYLORD MODEL CSU -7K -3W -ROOF TOP UNIT INDIRECT FIRED N. GAS _ /DX COOLING FlXED DISCHARGE MECHANICAL / ELECTRICAL COORD. UNLESS OTHERWISE INDICATED, AU. MECHANICAL EQUIPMENT MOTORS AND CONTROLS SHALL BE FURNISHED, SET IN PLACE AND WIRED IN ACCORDANCE WITH THE FOLLOWING SCHEDULE ''" ITEM FURNISHED BY SET BY POWER WIRING CONTROL WIRING EQUIPMENT MOTORS FUSED AND UN -FUSED DISCONNECT SWITCHES THERMAL OVERLOAD AND HEATERS CONTROL RELAYS AND TRANSFORMERS LOW VOLTAGE T'STATS TEMPERATURE CONTROL PANELS DUCT MOUNTED SMOKE DETECTORS MAGNEIIC MOTOR STARTERS: a. AUTOMATICALLY CONTROLLED WITH HOA SWITCHES (1 /2HP AND ABOVE) b. MANUALLY CONTROLLED c. FURNISHED WITH MECHANICAL EQUIPMENT. MC EC* MC MC MC EC EC MC MC MC EC MC MC MC MC F!' MC MC EC EC EC EC EC EC EC EC EC MC - - MC MC MC MC /EC MC MC MC PLUMBING FIXTURE LIST & ROUGH -IN SCHEDULE DESIGNATION DESCRIPTION WASTE VENT COLD HOT REMARKS ® HOT WATER HEATER - - 3/4" 3/4" 20 GPH RECOT 90 1 E UPPER & LOWER VERY ELE 'F V 600 4500 WATTS EMERGENCY EYE WASH /SHOWER 1"." ENAMELED -."' _- _ ^ S MODEL 8300 WffH 1 1/4" SINGLE POINT CONNECT! N� © MIXING VALVE yy TITUS 301RLHD STEEL DUCT MOUNTED LEONARD MIXING VALVE TM -:00- STSTL -EXP 1 1/4" OUTLET _ _ - WATER CLOSET CEILING DIFFUSER CDL 1" _ _ - KOHLER KINGSTON WATER -GUARD K- 4430 -ET VITREOUS CHINA SIPHON JET UR URINAL 2" 1 1/2" 1" - " KOHLER" K- 4970 -T STANWELL VITREOUS CHINA C> FLOOR DRAIN 2" 1 1/2" 1/2" - "JOSAM" C.I. SERIES 3000 -A ® LAVATORY 1 1/2" 1 1/2" 1 2" 1/2" GREENWICH VITREOUS CHINA "KOHLER" K -2032 DF� DRINKING FOUNTAIN 1 1/2" 1 1/2" 1/2" 7.6 GPH AT 50'F OUTLET 115V, 600 1/5 HP FAN COOLED SS SERVICE SINK 3" 1 1/2" 1/2" 1/2" REUSE EXISTING © HOSE BIB - - 3/4" - JR VACUUM SMITH BREAKER WALL HYDRANT MODEL 5509QT WITH INTEGRAL FN FUNNEL DRAIN 2" - - - JR SMITH FUNNEL DRAIN MODEL 3812T -DBS DRAINED DIRECTLY TO OUTSIDE 12" FROM TOP OF GRADE AIR TERMINAL SCHEDULE ITEM MARK MANUFACTURER MODEL MATERIAL MNT'G FINISH REMARKS RETURN GRILLE GRILLE TITUS 50F ALUMINUM DUCT MOUNTED ENAMELED EGGCRATE RETURN GRILLE SUPPLY GRILLE GRILLE TITUS 301RLHD STEEL DUCT MOUNTED ENAMELED 40' - 1/2" FIXED BLADES CEILING DIFFUSER CDL TITUS MCD STEEL DUCT MOUNTED ENAMELED BORDER TYPE 3 SYM A PIPING. ITEM DUCT / PIPE HANGER MISCELLANEOUS EQUIPMENT SCHEDULE MANUFACTURER REMARKS PORTABLE PIPE HANGERS INC. ROOF TOP DUCT / PIPE SUPPORT. MODEL PPH -D. A. DOMESTIC WATER PIPING: 1. ABOVE GRADE: USE TYPE L COPPER TUBING WITH WROUGHT COPPER FITTINGS AND 95/5 SOLDER JOINTS. 2. BELOW GRADE: USE TYPE K COPPER TUBING WITH WROUGHT COPPER FITTINGS AND BRAZED JOINTS. B. NATURAL GASS PIPING: 1. ABOVE GRADE: USE SCHEDULE 40 BLACK STEEL PIPE WITH 150# MALLEABLE IRON FITTINGS, ALL CONCEALED PIPING SHALL BE WELDED. 2. BELOW GRADE: USE SCHEDULE 40 BLACK STEEL PIPE WITH 150# MALLEABLE IRON FITTINGS. COAT THE PIPING AND FITTINGS IN ACCORDANCE WITH UTILITY COMPANY REQUIREMENTS. PROVIDE CATHODIC PROTECTION AS REQUIRED. C. VENT PIPING: 1. ABOVE GRADE: USE STANDARD WEIGHT CAST IRON NO -HUB PIPE. 2. BELOW GRADE: USE NO -HUB CAST IRON PIPE WITH NEOPRENE COUPLINGS AND STAINLESS TTEEL a:: DS OR SCHEDULE 40 PVC OR ABS. D. WASTE AND DRAINAGE PIPING: 1. ABOVE GRADE: USE STANDARD WEIGHT CAST IRON NO -HUB PIPE. 2. BELOW GRADE: USE NO -HUB CAST IRON PIPE WITH NEOPRENE COUPLINGS AND STAINLESS STEEL BANDS. REMODEL BRFAKROOM 9 -04 OFF LOAD RD/MICR REDRAWN TO ACAD FROM 109- 052 - 4000 -M8 J179461B -02 100002 -01 BY KB /CH CH JS APPROVED CW DATE 11.16.99 01.25.00 08.21.00 SYM REVISION APPROVED CONDENSING UNIT (CD) SCHEDULE MARK NUMBER CD3A UNIT SERVED AHU -5 CAPACITY MBH 147.9 SATURATED SUCTION TEMPERATURE 'F 44.0 MIV"■_■ MAU -1,2 27.0 44.0 CD1 AMBIENT EAT 'F OLAvaxwAv. 95 95 H. ACID RESISTANT PIPING: 1. PIPE: USE "ENFIELD" ACID WASTE PIPING AND COUPLING SYSTEM. ALL PIPE SHALL BE POLYPROPYLENE PIPE. F. COMPRESSED AIR PIPING: 1. PIPE: SEAMLESS STEEL, ASTM A106 GRADE B OR ASTM A53 GRADE B, SCHEDULE 40. 2. FITTINGS: 1 1/2" INCH AND BELOW: MALLEABLE IRON. 3. JOINTS: 1 1/2" INCH AND BELOW: THREADED. 4. VALVES: 2" INCH AND BELOW: BALL- HAMMOND BV811T. G. REFRIGERANT PIPING: 1. PIPE: USE TYPE L COPPER TUBING, REFRIGERANT GRADE, WHICH SHALL BE COLOR CODED AND MARKED "ACR" WITH WROUGHT FITTINGS AND 95% TIN - 5% ANTIMONY OR SILVER SOLDER. COMPRESSOR '•' STEPS R TYPE G EER QTY H SUCTION (IN) LIQUID (IN) Allinen01111101= 1/8 OD 7/8 OD 53.0 011101111131111111 DUCTWORK. A. ALL DUCTWORK SHALL BE GALVANIZED SILL. INSTALLATION SHALL CONFORM TO ALL THE SMACNA STANDARDS. B. THE GAUGE OF SHEET METAL SHALL BE IN ACCORDANCE WITH SMACNA STANDARDS. C. PROVIDE ALL SPLITTERS, BALANCING DAMPERS, HANGERS, ETC. AS REQUIRED BY THE SMACNA STANDARDS AND /OR AS SHOWN ON THE PRINTS. D. THE SIZES OF DUCTWORK SHOWN ON THE DRAWINGS REPRESENTS INSIDE DIMENSIONS AND DO NOT INCLUDE THE THICKNESS OF THE INSULATION OR ACOUSTICAL LINING. E. ALL DUCT HANGERS SHALL BE IN ACCORDANCE WITH THE SMACNA STANDARDS AND SHALL BE SUPPORTED FROM THE ROOF STRUCTURE, OR THE UPPER FLOOR STRUCTURE DUCTS SHALL BE MOUNTED AS HIGH AS POSSIBLE IN THE SPACE ABOVE THE CEILING. F. FURNISH AND INSTALL FLEXIBLE CANVAS CONNECTIONS BETWEEN AIR HANDLING UNITS AND DUCTS. WI 2 0 2 7 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE HECIQA Nt;INLtN CHECKED APPROVED FUSED AND UN -FUSED DICONNECT SWITCHES FOR EXPLOSION PROOF EXHAUST FANS PROVIDED BY MC. QTY 235.0 3 COND FANS PIPING CONNECTIONS GENERAL NOTES INSTALL SEISMIC BRACING FOR ALL DUCTWORK, EQUIPMENT AND PIPING PER U.B.C. REQUIREMENTS. INSTALL ALL PIPING ON ROOM SIDE OF BUILDING INSULATION. MECHANICAL DRAWINGS ARE DIAGRAMATIC IN NATURE, AND DO NOT NECESSARILY REFLECT EVERY REQUIRED OFF -SET, FITTING OR ACCESSORY. COORDINATE INSTALLATION OF MECHANICAL SYSTEMS WITH BUILDING STRUCTURE ANQ ALL OTHER TRADES. VISIT THE JOB SITE PRIOR TO BEGINNING WORK IN ORDER TO OBSERVE EXISTING CONDITIONS. VERIFY EXACT SIZE, LOCATION AND CONDITION OF ALL EXISTING SYSTEMS, DUCTS PIPES, UTILITIES AND BUILDING STRUCTURE. VERIFY VOLTAGES AT THE SITE PRIOR TO ORDERING ANY EQUIPMENT. SUBTITLE VOLT 460 ELECTRICAL PH EQUIPMENT LIST SCHEDULE MUTT DING 9 -52 HZ 60 60 ALP -012 AAON CA -02 -3 WITH HOT GAS BY -PASS ENERGY CODE NOTES EACH SYSTEM OR ZONE THERMOSTAT SHALL BE CAPABLE OF A DEADBAND OF. AT LEAST 5' F. WITHIN WHICH THE SUPPLY OF HEATING AND COOLING ENERGY IS SHUT -OFF OR REDUCED TO A MINIMUM. SEE SPECIFICATIONS. EACH HVAC SYSTEM SHALL HAVE AUTOMATIC CONTROLS WITH A MINIMUM SEVEN DAY CLOCK CAPABLE OF BEING SET FOR SEVEN DIFFERENT DAY TYPES PER WEEK. SEE SPECIFICATIONS. PROVIDE GRAVITY BACKDRAFT AND MOTORIZED DAMPERS WHERE SHOWN ON DRAWINGS AND /OR SPECIFIED, THAT WILL CLOSE AUTOMATICALLY WHEN IT'S RESPECTIVE SYSTEM IS OFF, OR UPON POWER FAILURE. SEE SPECIFICATIONS. DUCTWORK TRANSVERSE SEAMS SHALL BE SEALED IN ACCORDANCE WITH SMACNA DUCT METAL AND FLEXIBLE CONSTRUCTION STANDARDS, MOST RECENT EDITION. SUPPLY AND RETURN AIR DUCTWORK SHALL BE COVERED WITH INSULATION HAVING THE FOLLOWING R- VALUES: - DUCTS ON EXTERIOR OF BUILDING, IN ATTICS, IN ENCLOSED CEILING SPACES, IN WALLS, IN UN- HEATED ROOMS OR IN CRAWL SPACES, USE R -7. PROVIDE WEATHER PROOF BARRIER ON EXTERIOR INSULATION. - DUCTS IN CONCRETE OR UNDERGROUND USE R -5.3 - SUPPLY AIR DUCTS WITHIN CONDITIONED SPACE USE R3.3 OTHERWISE NOTED. - OUTSIDE AIR DUCTS, USE R -7. AIR ECONOMIZERS SHALL BE CAPABLE OF PROVIDING PARTIAL COOLING EVEN WHEN ADDITIONAL MECHANICAL COOLING IS REQUIRED TO MEET THE REMAINDER OF THE COOLING LOAD. CONTROLS SHALL NOT PRECLUDE THE ECONOMIZER FROM OPERATION WHEN MECHANICAL COOLING IS REQUIRED. AIR ECONOMIZERS SHALL BE CONTROLLED BY A SYSTEM CAPABLE OF DETERMINING IF OUTSIDE AIR CAN MEET ALL OR PART OF ALL THE RESPECTIVE SYSTEM COOLING LOAD. SEE SPECIFICATIONS. UPI Of 1UI(WILA Af'PROVI:D DEC I 1 2000 tioia CURRENT REVISION SHEET JOB N0. V REMARKS SYMBOL la 4nnnne, A4 HOT GAS BY -PASS UNLESS DATE COMP NO. 08.21.00 EIVLD TWW CE •ITE 1 1/2"V I EYE SHOWER INV 7' -10 3/8" ja ILL•th t ►' - REDRAWN TO ACAD FROM 109 - 052 - 4000 - N9 CW 3/4" f Hw 3/4" A REMODEL BREAKROOM J #794618 -00 VENT THRU ROOF 12.16.99 CONNECT SOLENOID VALVE TO EXHAUST FAN CONTROLS L. DEMO PLAN SCALE: 1/4 " =1' -0" ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY PIPING DEMO PLAN 9 -04 OFF LOAD ABOVE RESTROOM N rM DRAIN OUTSIDE THE BUILDING WOMEN 100002 -01 3 CONNECT TO PAINT BOOTH (PB1A02A) 3 A o C BREATHING AIR APPARATUS JS CW =7 1 2 COALESCING // FILTER 09.21.00 1-1-2 - COALESCING FILTER 01.eratezArAw. 1W 6' -6" INV 7' -3" 3/4" 4- 1 P1111 Whir_ Q R7 1 LEGEND - A COMPRESSED AIR - CW DOMESTIC COLD WATER - D - DRAIN -- G - GAS HW - DOMESTIC HOT WATER SUPPLY V VENT --- SAN SANITARY WASTE >< DEMOLISHED PIPE • 1. SEE SHEET 1M110 FOR NEW PLUMBING LAYOUT. 2. SEE SHEET RFM210 FOR NEW GAS PIPING LAYOUT. GEN CONSTRUCTION NOTES REMOVE AIR DROP AND CAP AT BALL VALVE. PLUG UNUSED VALVES RELOCATE EMERGENCY EYE WASH/ SHOWER TO PAINT CLEAN -UP AREA. REMOVE EMERGENCY EYE WASH. CAP WASTE AT SLAB. REMOVE COLD WATER SERVICE AND CAP ABOVE CEILING. RELOCATE SERVICE SINK, FAUCET, & TRAP STNDARD TO PAINT CLEAN -UP AREA. SEE SHEET 1M110. CAP WASTE AT SLAB. REMOVE HOT AND COLD WATER SERVICE AND CAP ABOVE CEILING. REMOVE VENT PIPING AND CAP ABOVE CEILING. REMOVE DRINKING FOUNTAIN. CAP WASTE AT WALL. REMOVE 3/4" COLD WATER CAP AT MAIN RUN. REMOVE VENT PIPING CAP AT CEIUNG. [Zi REMOVE SINK. CAP WASTE AT SLAB. REMOVE HOT AND COLD WATER SERVICE, CAP ABOVE CEILING. REMOVE VENT PIPING AND CAP ABOVE CBUNG. ® WATER SUPPLY PROTECTED DOWN STREAM BY 8" RPBP. INSTALLED 8/2000. REMOVE AIR DROP AND CAP AT TEE. REMOVE WATER DROP, CAP AT TEE. DEMO NATURAL GAS PIPING. DEMO NATURAL. GAS PIPING AND PATCH BUILDING PENITRATION. DEMO COMPRESSED AIR PIPING AND VALVES. PATCH', BUILDING PENETRATION. 1� DEMO PRV AND DOUBLE DETECTOR CHECK VALVE ASSEMBLY. DEMO FUNNEL DRAIN CAP WASTE AT SLAB. REMOVE AND REATACH HANGERS AS REQUIRED TO INSTALL NEW GYP CEILING. REMOVE AIR DROP AND CAP AT CEILING. 0ITY 2000 2--( CURRENT REVISION SYMBOL B p 100002 -01 SHEET JOB NO 1 VI 60 R CITY Of TUK;WILA APPROVED DEC. I 1 2000 DATE 08.21.00 COMP NO. PERMIT , K' LA NT R REV6 APPROVED REWSIGN D APPROVED a ®E wry® ACCEPTABILITY THIS DESIGN ANO /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN JS CW CHECKED 'ENGINEER CHECKED DATE 08.21.00 08.21.00 BRTLE ,4) PLUMBING PLAN LEGEND — D — DRAIN V - - - - -- VENT --- SAN- -- SANITARY WASTE —H4+— DEMOLISHED PIPE SAW CUT —CW -- COLD WATER GENERAL NOTES SLOPE TRENCH DRAIN LINES 1/16" PER 12" CONSTRUCTION NOTES I% 4" ACID RESISTANT WASTE TO TRENCH DRAIN. I/ 4" WASTE TO TRENCH DRAIN. 4" WASTE TO NEW PAINT COLLECTION TRENCH DRAIN. , 4" WASTE TO EXISTING PAINT COLLECTION TRENCH DRAIN. 12:>.' 4" WASTE TO EXISTING TRENCH DRAIN. © CONNECT TO TRAINLER SAW CUT CONCRETE FOR TRENCH DRAINS COORDINATE CUTTING WITH STRUCTURAL .. SAW CUT CONCRETE FOR WASTE PIPING COORDINATE CUTTING WITH STRUCTURAL PROVIDE INDMDUAL CORE DRILLS FOR EACH PIPE PENETRATING THE FOUNDATION. PROVIDE 6" MIN. SPACE CLEAR BETWEEN ADJACENT CORE DRILL HOLES. HR CONN PING NEW MAIN. 1 1/4" PIPING TO EXISTING V>• TRAILER. CORE DRILL FOR COLD WATER SUPPLY TO 21 CURRENT REVISION !SYMBOL SHEET ON 110 CITY OF Tb ,'r'+ILT AFPV00( D DEC 1 1 2000 TE RECE CCTV OF - KV LA I PERMIT CEN ER ��— r I 1 1 L IikiIIi Itf I Q I Ilili� IIIii{f V ' 4" -.- ' ° ' ° a CAP i WASTE AT TOP OF SLAB. P.O.C.4 INV 7' -10 3/8 "" I CW ., 3" W. UP r 1 4" y . �'E�— i �� 1 �� 1 f I a" D I ©r 1 • 7 © P.O.C. — I L -- 1 r J SEE DETAIL 0 110 . 5 J a" _ - D 1 \ / - L �I D i D / - I D 4 " I-._. 1111 I 1111 all - CAP WASTE AT I TOP OF SLAB. I J D CAP WASTE AT � . /[TOPOESLAB C.O. r " • " { ///���CE) �. SAN SAN I I ---1 v — 1 1 /2" 1 1 /4 "-- ::: P I 4" rn 0 ° ° it Q r 1 1.J 1- _I 1 °' ° D L -- - -- \ 4" ° O ° ° PIPING BELOW GRADE • �-(E) C. PLUMBING PLAN , wry ti ti ".1. a SCALE: 1/4 "= 1' -0 "' REV6 APPROVED REWSIGN D APPROVED a ®E wry® ACCEPTABILITY THIS DESIGN ANO /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN JS CW CHECKED 'ENGINEER CHECKED DATE 08.21.00 08.21.00 BRTLE ,4) PLUMBING PLAN LEGEND — D — DRAIN V - - - - -- VENT --- SAN- -- SANITARY WASTE —H4+— DEMOLISHED PIPE SAW CUT —CW -- COLD WATER GENERAL NOTES SLOPE TRENCH DRAIN LINES 1/16" PER 12" CONSTRUCTION NOTES I% 4" ACID RESISTANT WASTE TO TRENCH DRAIN. I/ 4" WASTE TO TRENCH DRAIN. 4" WASTE TO NEW PAINT COLLECTION TRENCH DRAIN. , 4" WASTE TO EXISTING PAINT COLLECTION TRENCH DRAIN. 12:>.' 4" WASTE TO EXISTING TRENCH DRAIN. © CONNECT TO TRAINLER SAW CUT CONCRETE FOR TRENCH DRAINS COORDINATE CUTTING WITH STRUCTURAL .. SAW CUT CONCRETE FOR WASTE PIPING COORDINATE CUTTING WITH STRUCTURAL PROVIDE INDMDUAL CORE DRILLS FOR EACH PIPE PENETRATING THE FOUNDATION. PROVIDE 6" MIN. SPACE CLEAR BETWEEN ADJACENT CORE DRILL HOLES. HR CONN PING NEW MAIN. 1 1/4" PIPING TO EXISTING V>• TRAILER. CORE DRILL FOR COLD WATER SUPPLY TO 21 CURRENT REVISION !SYMBOL SHEET ON 110 CITY OF Tb ,'r'+ILT AFPV00( D DEC 1 1 2000 TE RECE CCTV OF - KV LA I PERMIT CEN ER B 9 -04 OFF LOAD ABOVE RESTROOM 1/2" CW. DN 1 1/2' ETA - REDRAWN TO ACAD FROM 109- 052 - 4000 -M9 1 /2'HW. CW 3/4' HW DRAIN OUTBID THE BUILDING A REMODEL BREAKROOM J#794618 -00 100002 -01 CAP 1" - -- COLD WATER I I 3 I CONNECT)TJ 1 PAINT B00'H 1 /2F C T [P81aozA� -� ` 9OALESCING L____.. ____._ BREATHING AIR — APPARATUS P.O.C. -f 1/2" NW. 12.16.99 08.21.00 CONNECT SOLENOID VALVE TO EXHAUST FAN CONTROLS f HB 3/4" CW. DN. COALESCING FILTER 1" HW DN 1 "CWDN P.Q.C. — 1/2" — _.: P.O.C. PAINT SHAKER 3/4" CW. DN. HB n��;���mnm�lmnnmmin� TYP DROP SEE DETAIL 1M110 M501 ' CW. D. 1 TRW O. ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED CHECKED E NOINEER CO- VENT THRU ROOF -- - - -- -- -- 1" I I' A 1" e PLUMBING PLAN SCALE: 1/4 " =1' -0" a Z.ASFIZEZAW INIV 6' - INV 7-3" 1 . -J-- -L 1- 'C-3/4 CW. D. rr- - LEGEND A COMPRESSED AIR CW — DOMESTIC COLD WATER — D — DRAIN — G GAS HW — DOMESTIC HOT WATER SUPPLY V VENT - -- SAN SANITARY WASTE PW PROCESS WATER FIRST FLOOR PIPING PLAN DI III nIN.Ir' n R') 1 000 21 GENERAL NOTES Q RUN 1 1/4" COMPRESSED AIR EXPOSED UP THE OUTSIDE OF THE BUILDING TO MEZZANINE LEVEL. Q SEISMIC RESTRAINT HANGER. 1M110 M504 Q 2' GAS PIPE UP OUTSIDE OF BUILDING. FUNNEL DRAINED TO OUTSIDE OF BUILDING sEE DETAIL 1M110 M502 1. LOCATE ALL PLUMBING FIXTURES PER ARCHITECTURAL DRAWINGS. 2. DOMESTIC HOT WATER AND HOT WATER CIRCULATION PIPING UP TO 2" SHALL BE COVERED WITH 1" THICK INSULATION. PIPES 2 1/2" AND LARGER SHALL BE COVERED WITH 1 1/2" INSULATION. INSULATION SHALL HAVE A CONDUCTMTY RANGE OF 0.24 TO 0.28. SEE SPECIFICATIONS. CONSTRUCTION NOTES SUPPLY A RPBP FOR HOT WATER SUPPLY TO SERVICE SINK. [2> CONECT 1" HW & 1" CW TO LEONARD MIXING VALVE TYPICAL CONECTION. SEE DETAIL 1M110 I> 1/2" COMPRESSED AIR TO PAINT SHAKER. CITY Of TUCOIILA Af XiVf:L SHEET DEC 11 20 08 4. AL ILL CURRENT REVISION SYMBOL 100002 -01 1 V11 0 DATE 08.21.00 J RECEIVE [ CITY OF TUKWI PERMIT CENTER St Id A 9-04 OFF LOAD REASION 403 CFM „-- CF Mir , \ 403 CFM 11 100002-01 ILEY Or ,IS PAINT BOOTH #2 ) 32,000 CFM - - - -X- -- - X- - \/ 1 [2>-1 I -.---16,000 CFM X \ X ' r / N FT 1 F o 1 .7” CFM 2 1M1O M501 APPROVED CW PAINT BOOTH #1 DATE 08.21.00 403 CFM 1 r 32,000 CFM 16,000 CFM 411■ CFM , ..1/4" CU 008100 TO MAGNEHEUC ON WALL, SEE DETAIL 114_ 44. T 1 I I IDA I I 21( X- J_ _x_ _L _ \ \, 36/10 IL% \ --TYPICAL HANGER, SEE DETAILS I _ /A\ 1M1071 M505 1M10...1..... 1-M505 ...... ri-,4- 4>0 16/10 I HVAC DEMO SCALE: 1/4":---1'—o REASON NY 1M10 M501 WO 500 DATE --x 51- \ — 1M10 M501 - X - 1 — SFD- - F. -X- - 36/10 + -X- SFD- ZfirarEzAvda. I 1 - -x. - - - - ( 5.11-1‘ 4 APPROVED BY ACCEPTABILITY DAIS RESIGN 4N0/0e MCMARTIN IS APPROVED DEPT. (?) HVAC DEMO PLAN DI III 1111\IP RO LEGEND -x---x— DEMO. DUCT GENERAL NOTES CONSTRUCTION NOTES REMOVE MAKE UP AIR UNIT AND PATCH ROOF PENETRATIONS, REMOVE PAINT SPRIT( BOOTH AND ASSOCIATED EXHAUST FAN, PATCH ROOF PENETRATIONS. [1:i. REMOVE SUPPLY AND RETURN DUCT WORK AND ASSOCIATED DIFFUSERS FROM AHU-5. 1::::3' REMOVE SMOKE FIRE DAMPER AND PATCH OPENING. [..> REMOVE GRILLE AND DAMPER, PATCH OPENING. REMOVE DUCT HANGERS FROM DEMOLISHED DUCTWORK. CURRENT REV1S ON 100002-0 SHEET CITY DEC 1 1 20Y. MIAS Mil 08.21.00 crArt PE C 5 A REMODEL BREAKROOM 9 -04 OFF LOAD 300 CFM 12X6 CDL 12X6 12X10 CDL 500 CFM 12X10 11 1± 12X10 2X14 1 16X14 12X10 12X10 CDL 500 CFM 12X10 DN. 36X16 RETURN GRILLE 2175 CFM 1M10 M 36X16 12X6 CDL 300 CFM 26X2C 10X8 CDL --► 290 CFM (TYR. 4) 14X14 12010 CDL_ 500 CFM 12X1D Iu k _ pI 16X14-' 10X8 •I IIU1 10X8 ✓ 12X10 16X12 16X12 12010 1008 1008 REVISION REDRAWN TO ACAD FROM 109 -052- 4000 -M9 °I �- 32,OD0 0F Al \ 403 CFM ,I, CFM � 3 4794618 -OD 100002 -01 BY CH JS \ PAINT BOOTH fi APPROVED CW 1MI0IM501 DATE 12.16.99 8.21.00 SY REVISION 32,000 CFM 1/4" CU TUBING TO MAGNEHEUC ON WALL, SEE DETAIL HVAC FLOOR PLAN 0 SCALE: 1/4 " =1' -O" APPROVED / IT- F F'ilEf F[JF-F if [�FF!IIIl1Jl` i[IF 500 20018 26X20 15.67 - 26X20 12X12 CDL 800 CFM (r !P. 2) t ' ZLAntzezAw. - - 1 l T l -- l I '1 i - 12X12 DIFFUSE�RR 125 CFTA'� -6X6 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION B APPROVED APPROVED BY 12X10 CDL —�- 500 CFM M505 (rTP.2) DEPT. DATE N DIMWIT HECKED .12X10 CDL 500 CFM SUBTITLE i i.. 3) L1) VI 200 0' HVAC FLOOR PLAN DI III nlElh n R') 1 LEGEND j DIFFUSER • RETURN GRILL .POC POINT OF CONNECTION _ FLEXIBLE DUCT WITH VOLUME DAMPER tr=k RECTANGULAR DUCT, FIRST NUMBER INDICATES SIZE FOR SIDE SHOWN. ROUND DUCT, NUMBER INDICATES DIAMETER SUPPLY OUTLET AIR DIFFUSER /REGISTAR /GRILL. REFER TO SHEET MIA. 2 -WAY EARTHQUAKE BRACING, SEE SHT M504. X 4 -WAY EARTHQUAKE BRACING, SEE SHT M504. GENERAL NOTES 1. ALL UNIT HEATERS ARE MOUNTED ON THE ROOF. 2. ALL DUCT DIMENSIONS SHOWN ARE INSIDE CLEAR. 3 ALL DUCTS WHOSE GREATEST DIMENSION IS 30" OR LESS SHALL BE 24- GAUGE GALVENIZED SHEET METAL. 4. ALL DUCTS WHOSE LARGEST DIMENSION IS BETWEEN 31" AND 54" SHALL BE 22 GAUGE GALVANIZED SHEET METAL. 5. ALL DUCTS WHOSE LARGEST DIMENSION IS BETWEEN 55" AND 84-" SHALL BE 20 GAUGE GALVANIZED SHEET METAL. 6. ALL DUCTS WHOSE LARGEST DIMENSION IS GREATER THAN E.5 " SHALL BE 18 GAUGE GALVANIZED SHEET METAL. 7. REINFORCE DUCTWORK EVERY 4FT. MAX. AND SUPPORT EVERY 8FT. MAX. 8. ALL SUPPLY DUCTS WITHIN THE BUILDING SHALL BE WRAPPED WITH 2 "THICK, 1.5 POUND DENSITY FIBER GLASS INSULATION WITH AN ALUMINUM FOIL FACE, REINFORCED WITH FIBER FIBER GLASS YARN MESH AND LAMINATED TO FIRE RESISTANT KRAFT MANVILLE 800 SERIES SPIN GLAS WITH FSK FAC •R APPROVE' !UAL. 9. DIFFUSER SIZES INDICATED ARE NECK SIZES DIFFUSERS ARE 24 "X 24 ". 10. SEE DETAIL 6 SHEET M505. -( PROVIDE 2" WIDE 26 " GALVANIZED STRIP BOLTED TO WALL FOR SEISMIC RESTRAINT OF DUCT. Q EVERY EXHAUST D PER SHALL BE 20 GAUGE & REINFORCED Q DROP DUCT TO 12" A.F.F. PROVIDE WITH 1/2" X 1/2" SCREEN. DUCT SHALL OPEN TO FULL SIZE AT BOTTOM. ® SEE DETAIL 1 Y SCREEN. DUCT SHALL OPEN TO FULL SIZE AT BOTTOM. Q PROVIDE 6" X 6" BURGLAR SCREEN IN DUCT WORK PENETRATING ROOF. © SUPPLY REGISTER SERVICING MEZZANINE ABOVE. 'K EXHAUST SERVICING OIL DISPENSING AREA. CONSTRUCTION NOTES ROUTE DUCT UNDER GLUE LAM BEAM AT GRID LINE 3. ROUTE DUCT AS HIGH AS POSSIBLE. EMERGENCY SHUT -OFF FOR MAU -1, MAU -2 AND EF -3, EF -6, ® ROUTE DUCTWORK BETWEEN MEZZANINE STRUCTURE. CURRENT REVISION 100002 -01 SHEET SYMBOL 1v10 CI Y OF TIOIVVi! A OFF?ii ED DEC 1 1 2ea DATE 08.21.00 EN CITY 0 PEPM T C - REDRAWN TO ACAD FROM 109 -052- 400 -M10 A REMODEL OFFICE J1794618 -00 KB /CH 11.11.99 01.24.00 SEE SCHEMATIC RFM10 M503 16X16 ROOF PLAN SCALE: 1/4".1' -0 16X12 ACCEPTABILITY 11410 DESIGN Aw0//CR SPECIFICATION IS APPROVED CHECKED 16X12 - - HVAC ROOF PLAN RETURN REDLINE DRAWING SHOWNING ANY DEVIATIONS FROM ORIGINAL DESIGN TO ENGINEER: CHUCK HARRAH, M/S 46 -87 PHONE: 655 -3003. LEGEND REFERENCE DRAWINGS GENERAL NOTES CONSTRUCTION NOTES NEW MAKE UP AIR HANDLING UNIT. COORDINATE PLACEMENT OF UNITS AND LOCATION OF ROOF PENETRATIONS WITH STRUCTURAL & ARCHITECTURAL NEW CONDENSING UNITS. COORDINATE PLACEMENT OF UNITS WITH STRUCTURAL & ARCHITECTURAL. SEE CURB DETAIL ON ARCHITECTURAL DRAWINGS. DUCT SUPPORT TYPICAL SEE RF C5� INSULATE DUCT WITH R -7 RIGID INSULATION PROTECT WITH 22 GA. GALVANIZED SHEET METAL SEE DETAIL. 10 CURRENT REVISION 100002 -01 Cu TF Tt I,,; i f DEC I I TJ';-O DATE 08.21.00 SYM PRV f SEE DETAIL RFM 1 1/4" kIL 10 M5 5 REMODEL BREAKROOM REMODEL BREAKROOM REVISION REPLACE ROOF MOUNTING PIPING J#794618 -00 J #794618 -02 BY KGP CH CH APPROVED EJC DATE 8.295 12.16.99 01.25.00 REVISION ROOF PLAN SCALE: 1/4 " =1' -0" g rate APPROVED BY ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DEPT. DATE DRAWN K.PENROD CHECKED ENGINEER CHECKED BTRLE ROOF PIPING PLAN LEGEND GENERAL NOTES 1. ALL UNIT HEATERS ARE MOUNTED ON THE ROOF. CONSTRUCTION NOTES INSTALL NEW CONDENSING UNIT ON PAD WHERE SHOWN. ROUTE REFRIGERANT PIPING FROM NEW HVAC UNIT TO CONDENSER. SUPPORT PIPING EVERY 8 FEET. 18" A.F.F. SEE DETAIL RFM 10M 5 SUPPORT PIPING EVERY 8 FEET. 18" A.F.F. SEE DETAIL RFM 10 M5 5 ® TYPICAL GAS CONNECTICKE DETAIL RFM 101M500 ® CONNECT TO EXISTING 2" GAS PIPE OUTSIDE OF BUILDING. ROUTE 2" GAS PIPE UP TO ROOF. CURRENT REVISION 1 00002- 01 SHEET R V SYMBOL 210 CITY OF Aph�rp; p DEC 1 1 21`,1 D DATE 08.21.00 RECEI` ED CITY OF Y'J PERMIT < EN R 8 Di REVISION BY APPROVED Sr. REVISION APPROVED DA DAMPER MOTOR DAMPER MOTOR'S PRESSURE SENSOR -- _' O.S.A. V TEMP. SENSOR J/. RETURN AIR TEMP. PRESSURE SENSOR MIXED AIR /TEMP. SENSOR Zi_AvalEema. FAN START/ STOP CURRENT J TRANSFORMER DISC CONTROL PANEL FAN START/ STOP CURRENT SWITCH MAKE UP AIR UNIT (TYPICAL) CURRENT TRANSFORMER TEMP. SENSOR GAS HIGH /LOW HEAT START /STOP TEMP. SENSOR - 0 MODULATING GAS VALVE AHU -5 CONTROL DIAGRAM 24 VOLT SEQUENCE OF OPERARTION ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. COND. UNIT COND. UNIT 1 START/ STOP STOP START/ ROOM TEMP. SENSOR T MAU CONTROL DIAGRAM - MUA -1 & 2 TYPICAL WIRING DIAGRAM MAU -1: FAN SMALL RUN CONTINUOUSLY. DAMPER SHALL BE OPEN. ON A CALL FOR HEAT AS SENSED BY A ROOM SENSOR, GAS VALVE SHALL ACTIVATE IN LOW HEAT TO MINIMUM POSITION TO MAINTAIN SPACE TEMPERATURE. ON A FURTHER CALL FOR HEAT GAS VALVE SHALL ACTIVATE IN HIGH HEAT TO MAINTAIN SPACE TEMPERATURE. ON A CALL FOR COOUNG THE FIRST CONDENSING UNIT (CU -1) SHALL ACTIVATE AND ON A FURTHER CALL FOR COOUNG THE 2ND CONDENSING UNIT (CU -1) SHALL ACTIVATE. EXHAUST FAN 5 SHALL ALSO RUN CONTINUOUSLY. AN EMERGENCY OFF SWITCH (PROVIDED AND INSTALLED BY DIVISION 16) SHALL TURN OFF MAU -1 AND (2) CU -1, AND EF -5. MAU -2: FAN SHALL RUN CONTINUOUSLY. DAMPER SHALL BE OPEN. ON A CALL FOR HEAT AS SENSED BY A ROOM SENSOR, GAS VALVE SHALL ACTIVATE IN LOW HEAT TO MINIMUM POSITION TO MAINTAIN SPACE TEMPERATURE. ON A FURTHER CALL'. FOR HEAT GAS VALVE SHALL ACTIVATE IN HIGH HEAT TO MAINTAIN SPACE TEMPERATURE. ON A CALL FOR COOLING THE FIRST CONDENSING. UNIT (CU -1) SHALL ACTIVATE AND ON .A FURTHER CALL FOR COOUNG THE 2ND CONDENSING UNIT (CU -1) SHALL ACTIVATE. EXHAUST FAN 3 SHALL ALSO RUN CONTINUOUSLY. AN EMERGENCY OFF SWITCH (PROVIDED AND INSTALLED BY DIVISION 16) SHALL TURNOFF MAU -1 AND (2) CU -1, AND EF -3. MAU -3: FAN SHALL BE CONTROLLED BY A SWITCH ON THE FUME HOODS. WHEN THE SWITCH IS ACTIVATED THE OUTSIDE AIR DAMPER SHALL BE OPEN. ON A CALL FOR HEAT AS SENSED BY DISCHARGE AR SENSOR, GAS VALVE SHALL ACTIVATE IN LOW HEAT TO MINIMUM POSITION TO MAINTAIN SPACE TEMPERATURE. ON A FURTHER CALL FOR HEAT GAS VALVE SHALL ACTNATE IN HIGH HEAT TO MAINTAIN SPACE TEMPERATURE.. EXHAUST FAN 9 SHALL BE INTERLOCKED WITH MAU -3. AHU -5: FAN SHALL RUN CONTINUOUSLY. OUTSIDE AIR DAMPER SHALL BE OPEN TO MINIMUM OUTSIDE AIR POSITION SHOWN ON DRAWINGS. ON A CALL FOR HEAT GAS VALVE SHALL MODULATE TO MAINTAIN SPACE TEMPERATURE. ON A CALL FOR COOLING THE FIRST STAGE OF CONDENSING UNIT (CD3A) SHALL ACTIVATE AND ON A FURTHER CALL FOR COOLING THE 2ND CONDENSING UNIT (CD3A) SHALL ACTIVATE. EXHAUST FANS '1, 2, 6, 7 AND 8 SHALL flq ALSO RUN CONTINUOUSLY. DATE DRAWN JS CHECKED UBIINECH CHECKED COND. UNIT START /START / STOP STOP RELAY PANEL DATE 08.21.00 08.21.00 CURRENT SWITCH SUBTRLE TIRE CURRENT TRANSFORMER LINE LINE VOLTAGE DAMPER MOTOR PRESSURE SENSOR MAU CONTROL DIAGRAM - MUA -3 TYPICAL EXHAUST FAN CONTROL DIAGRAM CONTROLS DRAWING nI III TIIAI/' (1 C/'I I ELECTRICAL PANEL EXHAUST FAN (TYPICAL) 00" FAN START/ STOP CURRENT REVISION SHEET TEMP. SENSOR HIGH / LOW GAS HEAT CURRENT SWITCH SYMBOL V1300 FAN START /STOP CURRENT TRANSFORMER CONTROL CONTRACTOR AS A SOLE SOURCE SUPPLIER. GOY Ti TUI'Y ILi A' F PRCAF : . n., r, I. DEC 1 )C) TE REN KWILA clTV c,= PERMS NTER INPUTS OUTPUTS SYSTEM EATURES ANALOG DIGITAL ANALOG DIGITAL 3-PT ALARMS OTHER DESCRIPTION TEMPERATURE PRESSURE HUMIDITY /MOISTURE POSITION INDICATION FLOW RATE I CURRENT TRANSMITTER SETPOINT ADJUSTMENT PULSE INPUT { HUlIMS MOld Vida CURRENT RELAY FREEZESTAT SMOKE DETECTOR STATUS CONTACTS MOTION DETECTION SWITCH POSITION OVERRIDE DAMPER POSITION CONTROI VALVE POSITION CONTROL SETPOINT ADJUST VFD SPEED CONTROL HUMIDIFIER OUTPUT ON/OFF LO /HI /OFF OPEN /CLOSE ENABLE /DISABLE REVERSING VALVE DAMPER POSITION VALVE POSITION HIGH LIMIT LOW LIMIT RUN FAIL MAINTENANCE EQUIPMENT SAFETY FIRE /LIFE SAFETY COMMON ALARM OFF SCHEDULE LINE COLOR GRAPHIC GAS OR ELECTRIC USAGE RUN TIME MAKE -UP AIR UNITS 1 &2 X SUPPLY FAN START /STOP X X X SUPPLY FAN STATUS X X DAMPER MOTOR OPEN /CLOSE X FILTER DIFFERENTIAL PRESSURE X X X SUPPLY AIR TEMPERATURE X X X GAS HEAT HI /LOW X CONDENSING UNIT START /STOP CU -1,2 X X CONDENSING UNIT START /STOP CU -1,2 X X CONDENSING UNIT STATUS X CONDENSING UNIT STATUS X SPACE SENSOR X X X EX. FAN START /STOP EF -3 &5 X EX. FAN STATUS EF -3 &5 X I X MAKE -UP AIR UNIT 3 X SUPPLY FAN START /STOP X X X SUPPLY FAN STATUS X X DAMPER MOTOR OPEN /CLOSE X FILTER DIFFERENTIAL PRESSURE X X X SUPPLY AIR TEMPERATURE X X X GAS HEAT HI /LOW X SPACE SENSOR X X X EX. FAN START /STOP EF -8 X EX. FAN STATUS EF -8 X X AIR HANDLING UNIT 5 X SUPPLY FAN START /STOP X X X SUPPLY FAN STATUS X - X SUPPLY AIR TEMPERATURE X X X RETURN AIR TEMPERATURE X X X MIXED AIR TEMPERATURE X X X GAS HEAT MODULATION X OUTSIDE /RETURN AIR DAMPER X CONDENSING UNIT STATUS X CONDENSING UNIT START /STOP CD -3 X X CONDENSING UNIT START /STOP CD -3 X X FILTER STATUS X X X SPACE SENSOR X X X EXHAUST FANS 8 (2), EF -5 (1), EF -6, EF -1 X FAN START /STOP X X X FAN STATUS X X GENERAL OUTSIDE AIR TEMP X REVISION BY APPROVED Sr. REVISION APPROVED DA DAMPER MOTOR DAMPER MOTOR'S PRESSURE SENSOR -- _' O.S.A. V TEMP. SENSOR J/. RETURN AIR TEMP. PRESSURE SENSOR MIXED AIR /TEMP. SENSOR Zi_AvalEema. FAN START/ STOP CURRENT J TRANSFORMER DISC CONTROL PANEL FAN START/ STOP CURRENT SWITCH MAKE UP AIR UNIT (TYPICAL) CURRENT TRANSFORMER TEMP. SENSOR GAS HIGH /LOW HEAT START /STOP TEMP. SENSOR - 0 MODULATING GAS VALVE AHU -5 CONTROL DIAGRAM 24 VOLT SEQUENCE OF OPERARTION ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. COND. UNIT COND. UNIT 1 START/ STOP STOP START/ ROOM TEMP. SENSOR T MAU CONTROL DIAGRAM - MUA -1 & 2 TYPICAL WIRING DIAGRAM MAU -1: FAN SMALL RUN CONTINUOUSLY. DAMPER SHALL BE OPEN. ON A CALL FOR HEAT AS SENSED BY A ROOM SENSOR, GAS VALVE SHALL ACTIVATE IN LOW HEAT TO MINIMUM POSITION TO MAINTAIN SPACE TEMPERATURE. ON A FURTHER CALL FOR HEAT GAS VALVE SHALL ACTIVATE IN HIGH HEAT TO MAINTAIN SPACE TEMPERATURE. ON A CALL FOR COOUNG THE FIRST CONDENSING UNIT (CU -1) SHALL ACTIVATE AND ON A FURTHER CALL FOR COOUNG THE 2ND CONDENSING UNIT (CU -1) SHALL ACTIVATE. EXHAUST FAN 5 SHALL ALSO RUN CONTINUOUSLY. AN EMERGENCY OFF SWITCH (PROVIDED AND INSTALLED BY DIVISION 16) SHALL TURN OFF MAU -1 AND (2) CU -1, AND EF -5. MAU -2: FAN SHALL RUN CONTINUOUSLY. DAMPER SHALL BE OPEN. ON A CALL FOR HEAT AS SENSED BY A ROOM SENSOR, GAS VALVE SHALL ACTIVATE IN LOW HEAT TO MINIMUM POSITION TO MAINTAIN SPACE TEMPERATURE. ON A FURTHER CALL'. FOR HEAT GAS VALVE SHALL ACTIVATE IN HIGH HEAT TO MAINTAIN SPACE TEMPERATURE. ON A CALL FOR COOLING THE FIRST CONDENSING. UNIT (CU -1) SHALL ACTIVATE AND ON .A FURTHER CALL FOR COOUNG THE 2ND CONDENSING UNIT (CU -1) SHALL ACTIVATE. EXHAUST FAN 3 SHALL ALSO RUN CONTINUOUSLY. AN EMERGENCY OFF SWITCH (PROVIDED AND INSTALLED BY DIVISION 16) SHALL TURNOFF MAU -1 AND (2) CU -1, AND EF -3. MAU -3: FAN SHALL BE CONTROLLED BY A SWITCH ON THE FUME HOODS. WHEN THE SWITCH IS ACTIVATED THE OUTSIDE AIR DAMPER SHALL BE OPEN. ON A CALL FOR HEAT AS SENSED BY DISCHARGE AR SENSOR, GAS VALVE SHALL ACTIVATE IN LOW HEAT TO MINIMUM POSITION TO MAINTAIN SPACE TEMPERATURE. ON A FURTHER CALL FOR HEAT GAS VALVE SHALL ACTNATE IN HIGH HEAT TO MAINTAIN SPACE TEMPERATURE.. EXHAUST FAN 9 SHALL BE INTERLOCKED WITH MAU -3. AHU -5: FAN SHALL RUN CONTINUOUSLY. OUTSIDE AIR DAMPER SHALL BE OPEN TO MINIMUM OUTSIDE AIR POSITION SHOWN ON DRAWINGS. ON A CALL FOR HEAT GAS VALVE SHALL MODULATE TO MAINTAIN SPACE TEMPERATURE. ON A CALL FOR COOLING THE FIRST STAGE OF CONDENSING UNIT (CD3A) SHALL ACTIVATE AND ON A FURTHER CALL FOR COOLING THE 2ND CONDENSING UNIT (CD3A) SHALL ACTIVATE. EXHAUST FANS '1, 2, 6, 7 AND 8 SHALL flq ALSO RUN CONTINUOUSLY. DATE DRAWN JS CHECKED UBIINECH CHECKED COND. UNIT START /START / STOP STOP RELAY PANEL DATE 08.21.00 08.21.00 CURRENT SWITCH SUBTRLE TIRE CURRENT TRANSFORMER LINE LINE VOLTAGE DAMPER MOTOR PRESSURE SENSOR MAU CONTROL DIAGRAM - MUA -3 TYPICAL EXHAUST FAN CONTROL DIAGRAM CONTROLS DRAWING nI III TIIAI/' (1 C/'I I ELECTRICAL PANEL EXHAUST FAN (TYPICAL) 00" FAN START/ STOP CURRENT REVISION SHEET TEMP. SENSOR HIGH / LOW GAS HEAT CURRENT SWITCH SYMBOL V1300 FAN START /STOP CURRENT TRANSFORMER CONTROL CONTRACTOR AS A SOLE SOURCE SUPPLIER. GOY Ti TUI'Y ILi A' F PRCAF : . n., r, I. DEC 1 )C) TE REN KWILA clTV c,= PERMS NTER SYM A SIDE T- 6x2' -O" PERFORATED PLATE BOTTOM 1T- 6'x1' -6" PERFORATE PLATE 50% MINIMUM OPEN AREA 32000 CRA C 1050 FPM MAX WITH (7) 28 1/2 x24 DIFFUSERS ON TOP 8 7 28 1/2"x18' DIFFUSERS CN BOTTOM FIN FLOOR 2'A4' ROLL UP D REPLACE PERFORATED DIFFUSERS 9 -04 OFF LOAD 18'x3'- 6 "x2' -0" PLENUM REVISION 100002 -01 SECTION SCALE 1/4" =1' -0' BY REVBYT JS APPROVED CW DATE 08.21.00 1(A � REV6ION APPROVED DETAIL SCALE: NONE DATE FM1 ZiArovErAw. PRESSURE REDUCING VALVE SET AT 29 PS1 TO 11' W.C. PRESSURE REGULATOR DETAIL n SCALE NO SCALE RFM210 X500 PIPE ROUTED 18' A.F.F. GAS RWRD EQUIPMENT REDUCER AS REQUIRED DRIP LEO ASSEMBLY , TYPICAL GAS CONNECTION DETAIL SCALE NO SCALE RFM2 M M500 \_ SLOPE PIPE .5% TIE INTO TRENCH WITH PIPE 2" BELOW SLAB SECONDARY SPILL CONTAINMENT TYPICAL TRENCH DRAIN CONNECTION DETAIL SCALE NO SCALE OM110 M500 NOTE FOR ADD'L INFO SEE SECT SECTION SCALE 1/4" =1' -0" 2DO&2J 7 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION B APPROVED APPROVED BY DEPT. DATE 1M10 M500 DRAWN DATE SUBRTLE .`GINEER SECTIONS AND DETAILS DI III nINIr ( RO 1 LEGEND GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES CURRENT REVISION 100002 -01 SHEET SYMBOL V1500 CITY OF T000IIa, APPROVED DEC 1 1 205g DATE 08.21.00 „AVM PERMIT E ENT FRSH AIR INTAKE REDRAWN TO ACAD ROOF EXHAUST GRILLE 18x11 ALUMINUM W/1/2" x1 /2" SQUARES NOTE: FAN FAIL ACTIVATE ALARM. FLAMMABLE STORAGE DETAIL _ T SCALE: NONE iM10 M50M50 1 REVISION MIXING BOX RETURN AIR 1 1/2 "x1 1/2 "x1 /81 AROUND DUCT GRILLE ALUMINUM FIN FLOOR PLUMBING MME CHASE v ROOF CURB PROVIDED WITH EXHAUST FAN FS -1 FLOW SWITCH W /TIME DELAY EXPLOSION PROOF v FILTER SECTION v ,,,--1/4" COPPER BLOWER SECTION 1/4" COPPER TUBING TO MAGNEHELIC AT FLOOR LEVEL, SEE DETAIL 1M10 M500 60 EXHAUST STACK DOUBLE WALL ONE HALF OF DUCT DAMPERED. UNDAMPERED HIGH VELOCITY HALF DIRECTED AT ROLL—UP DOOR TO OUTSIDE. UNIT HEATER DETAIL 1M10 M501 SCALE: 1/2 " =1' -0" BY KB /CH APPROVED DATE 2.15.97 Cr BURNER SECTION 403 CFM SPLITTER NOTE: THI5 EXHAUST FAN INTERLOCKED WITH RESTROOM LIGHTS. ROUND TOP CAP 16 GAGE GALV GUY WIRE RING WIRE ROPE CLAMP WITH THIMBLES (3) 3/16 "4 GUY WIRE (3 TYPICAL) 8' -0" 1 126/26 MOTORIZED DAMPER REM9DN ROOF CURB PROVIDED WITH EXHAUST FAN ROOF MECHANICAL ROOM FLOOR RESTROOM CEILING 403 CFM W/1/2 "x1/2" SQUARES RESTROOM EXHAUST DETAIL SCALE: NONE 1 M501 M501 M502 APPROVED DA DUCT GRILLE WALL 11 GAGE GALV STL FRAME 14 "x14" OPENING POP RIVET ALUMINUM GRILLE W/1/2 "x1/2" SQUARES 786 CFM #8x1 1 /2 "LG OVAL HEAD PHILLIPS RECESS SHT MTL SCREWS FIN FLOOR--,, #8x3/4" LG. OVAL HEAD PHILLIPS RECESS SHEET METAL SCREWS DETAIL SCALE: NONE FIRE DAMPER DETAIL SCALE: NONE ZLAsmomov.g. M501 20 GA FRAME OUT COLLAR TO INSURE CLEARANCE FOR DAMPER TO OPERATE FUSIBLE LINK FD -1 FLAMMABLE STORAGE #8x1 1 /2 "LG. ROUND HEAD PHIWPS RECESS SHT MIL SCREW @ MAX 2" FROM CORNERS AND MAX 8 OC ALL AROUND M10 M50 1 M501 D_ ALUNIMUM STACK COVER MIN 14 GA GALV IRON FAN SECTION LINE STACK OPENING W /18 GA GALV IRON & EXTEND AS SHOWN—" ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE BACK OF PAINT BOOTH-" 2' -10 DETAIL SCALE: 1/2 " =1' -0" DRAWN CHECKED NOT CHECKED AIR DROP DETAIL SCALE: NONE 2 -0" 2' - 2" 2' -3" DA 8' -0" 2' -0" I ? - 0" SUBTTRE 2 - NOTE SEE SK NO. 250 -44 FOR MORE INFORMATION. 1/2" TEE 1/2" STREETELL (2 TYPICAL) QUICK DISCONNECT (2 TYP) 30' PROVIDE 3 EA Z SPACER BRACKETS SPACED AT 120', STACK MUST BE SUSPENDED INDEPENDENTLY OF THESE SPACERS. FIN FLOOR M500 M501 COVER EXHAUST STACK W /METAL MESH FIBERGLASS BLANKET INSULATION W /20 GA GALV IRON FACE & EXTEND AS SHOWN. INSULATION SHALL BE HIGH TEMPERATURE RESISTANCE TYPE W /OUT RESIN BINDER " -- EXSTEND WOOD BM SEE ARCH /STRUCT ,e--ROOF OF PAINT BOOTH DETAILS 1/2" 90' ELL OR TEE W/1/2" REDUCED BRANCH STRUT & PIPE CLAMP WALL SUPPORT PHI! nfM( 0_ 1 LEGEND: GENERAL NOTES: Vv%ThDcy zi CONSTRUCTION NOTES: CURRENT REVISION SHEET JOB NO. V SYMBOL 501 TE COMP NO. C ATTU< PERMIT CEP TER SYM A 9 -04 OFF LOAD PILOT GAS VALVE & PRESS. REG. WASTE & VENT PIPING DIAGRAM SCALE: NONE 1" SUPPLY (TYPICAL) UNION (TYPICAL) CW HW TH I RMOSTAT 1 -1/4 OUTLET TYPICAL) N- MIXING VALVE DETAIL SCALE: NONE THERMO ANC MIXING V VE VALVE (TYPICAL) EXPOSED STAINLESS STEEL CABINET WITH HINGED DOOR AND CYLINDER LOCK. (TYPICAL) 1M110 M502 _ PILOT_ BURNER TEST LUBRICATED PLUG VALVE HIGH PRESSURE GAS INTRLX. (METERING VALVE) ACTUATOR MOTOR (MOTORIZED BLOCK VALVE) ACTUATOR MOTOR (MOTORIZED MAIN GAS VALVE) ACTUATOR MOTOR REVISION REDRAWN TO ACRD FROM 109 -052- 4000 -M2 JS UH -2 PIPING SCHEMATIC SCALE: NONE 100002 -01 BY KB /CH APPROVED CW LOW PRESSURE GAS INTRLK. MAIN GAS LUBRICATED PLUG VALVE DATE 11.16.99 08.21.00 PILOT MANUAL SHUTOFF VALVE PRE -PIPED W UNIT PIPING BALL VALVE WATTS 8 -6800 SERIES GAS PRESS. REGULATOR FIELD 2 RFM1 I5L2 —DRIP LEG REVISION 3/16 "9 WIRE CABLE DOUBLE CLEVIS LINK 5/8 "0x4" LONG LAG EYEBOLT BUILD UP ROOF 2"T &G WOOD BEAM OR GLUE -LAM BEAM — BY GUY TIE —DOWN DETAIL n SCALE: NONE M52111,1502 APPROVED DATE Id � N N EOGROUND BO ROOF 80 BE OO \ C 1 1 COMBINATION CLAMP AND THIMBLE TURNBUCKLE EYE & EYE PITCH PAN FIELD WITH HOT PITCH OR PLASTIC CEMENT ZLAraweAw. APPROVED BY 4" ACCEPTABILITY THIS DESIGN AND /oR SPECIFICATION IS APPROVED DEPT. DATE 0 DRAWN PIP CRECRGD LNUINOAK CHECKED kkt Ckg HOT & COLD WATER DIAGRAM SCALE: NONE UNION DETAIL SCALE: NONE • s 'sr.." \< -- BACK FLOW PREVENTER PRESSURE GAGE 0 -200 P51G GATE VALVE yy UNION Il GLOBE VALVE FLOW P.R.V. / PROCESS WATER STATION DRAIN TO f OUTSIDE OF BUILDING GATE VALVE REGULATOR WI STRAINER & UNION ' GAGE 0 -200 PSIG 1 M1'10150 2 SUBTITLE LEGEND GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES yV'' DETAILS nI III nIAln n G n CURRENT REVISION 100002 -01 SHEET V SYMBOL A 502 CITY CF r�lr,��!i.h DEC 1 1 << =JO DATE 08.21.00 • PERMI TER SYM A 9 -04 OFF LOAD NOTE; GRINNEL FIG. 205 FOR 2" 0 PIPE & UNDER TYPE "A" RENSION UNISTRUT P -1047 PTIONAL MOUNTING REDRAWN FROM MYLAR /109 -052- 4000 -M4 1/4 "0 FLATHEAD WOOD SCREW (T(P) .3300 TYPICAL SPRINKLER PIPE HANGARS SCALE: NTS GLULAM OR 6x4 WOOD BEAM U" SHAPE FITTINGS UNISTRUT P -1047 1/2 "0 THREADED ROD - LENGHT VARIES UNINSULATED PIPE CLEVIS HANGER CLEVIS HANGER FIG. 260 FIG. 260 GRINNELL GRINNEL. 11/16" CABLE CONNECTOR BRACKET DETAIL ( L 1 M504 M504 100002 -01 2" JS 1 -7/6" PROVED CW TYPE "B" CLEVIS HANGER FIG. 102 "FEE & MASON" 3/16" DATE 06.21.00 LAG BOLT ( TYPE "C" TYPE "D" INSULATED PIPE U.QIF• TYPICAL HANGER ROD SIZE AS FOLLOWS: 3/6 "0 ALL THREAD FOR 2 "0 PIPE AND UNDER, 1/2 "0 ALL THREAD FOR 2 1/2 "0 THRU 3 1/2 "0 PIPE, 5/B "0 ALL THREAD FOR 4 "0 AND 5 "0 PIPE 3/4 "0 ALL THRESSA FOR 6 "0 PIPE. PIPE SUPPORT DETAIL SCALE: NONE REVISION L 3/0"0 ROD FOR 2 "0 PIPE & UNDER SEE GRINNELL FIG. 269 INSULATION INSULATION PROTECTION FIG. 167 GRINNELL APPROVED LOG BOLT & WASHER 3/4 "0 ROD FOR 6 "0 PIPE SEE GRINNEL FIG. 269 PIPE HANGER FIG. 260 GRINNELL FIRE PROTECTION 2 -WAY EARTHQUAKE BRACE SCALE: NONE ACCEPTABILITY IRIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN CHECKED LNUINF2N CHECKED DATE 4 -WAY EARTHQUAKE BRACE SCALE: NONE c /N° NEOPRENE GROMMET ( NOT REQUIRED FOR NON- ISOLATED PIPING) CABLE CONNECTOR BRACKET SEE DETAIL SEISMIC CABLE RESTRAINT DETAIL 1M110 M504 CABLE CUPS (SAME SIZE AS CABLE) MUST BE ORIENTED AS SHOWN WITH SHORT END OF CABLE ON THE CURVED PART OF THE CUP. M5041M504 SUBTITLE rnZOOO 217 BRACING SECTIONS & DETAILS LEGEND GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES CURRENT REVISION 1 00002 -01 SHEET V SYMBOL 504 GTY OF FIITT'IIA AP r92OKO DEC 1 1 2GC) A r;i)iLt DATE 08.21.00 PE ;EN rn SUPPLY AIR DIFFUSER DETAIL SCALE: NONE �— DUCT ROUTED EXPOSED IN CEILING SPACE DIFFUSER CONNECTED / TO DUCT ADJUSTABLE PATTERN CONTROLLERS 1M M505 B -LINE B -22 GRI STUDNUT AND 1/2" NUT (TYP) BOLT 22 GAUGE GALV. STRAPS. AROUND NEW OR EXISTING B -LINE CHANNEL AND ROUND OR RECTANGULAR DUCTWORK DETAIL - UNISTRUT DUCT SUPPORT SCALE: NONE 1M M505 B -LINE B132 FITTING W/(4)1/2" DA x1 1/4" LONG B -LINE HEX HEAD CAP SCREW AND SPRING NUT FIRE SEPARATION SHEET METAL SLEEVE PER NPPA SYM 18" MIN SEE MISCELLANEOUS SCHEDULE SHEET M1A ROOF TOP DUCT / PIPE SUPPORT DETAIL �I SCALE: NONE RFM10 M505 A 9 -04 OFF LOAD 100002 -01 BY JS APPROVED CR DATE 08.21.00 SYM REVISION EXISTING WOOD B -LINE B107S AND B593 FITTING WITH (2)1/2 "0 x 3" LONG LAG SCREW �B -LINE B -22 GRID mln"∎ ∎1N. BOLT 22 GAUGE GALV. STRAPS. AROUND NEW OR EXIST UNISTRUT CHANNEL AND ROUND OR RECTANGULAR - DUCTWORK DETAIL - DUCT HANGER SCALE NONE 3/8" BOLT AT 6 ON CENTER -- CANT STRIP 3/8" BOLT (TYPICAL 8 PLACES) \ A APPROVED %II ∎II_ FLASHING Z f EQUIPMENT 8X6 CURB d- ROOF y 1 M10 t 505 B -LINE ATR 1/2 "0 THREADED ROD WITH (2) NUTS AT TOP AND BOTTOM B -UNE B132 FITTING W/(4)1/2" DA x1 1/4" LONG B -UNE HEX HEAD CAP SCREW AND SPRING NUT EQUIPMENT ROOF SUPPORT WITH SEISMIC RESTRAINT DETAIL n SCALE: NONE' RFM10 M505 INSULATED DUCT DETAIL SCALE: NONE EXHAUST FAN - ROOF ( EXHAUST DUCT DROP DUCT T 12" A.F.F. PROVIDE WITH 1/2" X 12" SCREEN DUCT SHALL OPEN TO FULL SIZE AT BOTTOM. `12" A.F.F. TYPICAL EXHAUST DUCT DETAIL SCALE: NONE 1M M505 DUCT R -7 RIGID INSULATION. 22 GAUGE GALVANIZED SHEET METAL 2" LAPPED SEAMS. PROVIDE SILICONE CAULKING. RFM101M505 CURRENT REVISION 100002 -01 SYMBOL A DATE 08.21.00 FIRE DAMPER TYPICAL FIRE DAMPER DETAIL SCALE: NONE MOUNTING ANGLE PER NFPA SLIP JOINT, TYP. SHEET METAL DUCT 2" MIN (TYP) SEE DETA M505 iM M505 QLArOE /NQ INSTALL 14 "x2007 s PANEL OF IDENTICAL GAUGE METAL AS DUCT, GLUE ALL EDGES OF SOUNDLINING WITH HARDCAST DUCT SEALER, ALLOW DUCT SEALER TO DRY COMPLETELY BEFORE SECURING PANEL WITH TEK SCREWS 4" ON CENTER AND FOAM GASKETI ® DUCT HEIGHTS LESS THAN 14 ", MAKE PANEL HEIGHT 2" LESS THAN DUCT HEIGHT. ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE C. HARRAH CHECKED E NUINEEH NECKED DATE SUBTITLE CUT 12" HIGH BY 18" WIDE RECTANGULAR HOLE IN DUCT AND LINING NOTE: INSULATION CONTRACTOR TO MARK OUTLINE OF RECTANGULAR ACCESS PANEL WITH BLACK PERMANENT FELT TIP MARKER AND CROSS HATCH INTERIOR OUTLINE. DETAIL - --LOW PRESS. DUCT ACCESS PANEL r SCALE: NONE M`05 LOW PRESSURE, RECTANGLAR INSULATED, DUCT SHEET LEGEND GENERAL NOTES CONSTRUCTION NOTES Thzbfr 2 DEC 1 1 20°A OTT'] OFETOY V PERMIT CERTE