Loading...
HomeMy WebLinkAboutPermit M99-0221 - NC MACHINERYM99 -0221 ., ...c.. s. < d�?:'f�. "•... s "k'11M1 Sr ,ry .".I r�Sf ;F`.itiwt�'S47 w'e3h:?9 17035 W. Valley Hwy. NC Machinery City of Tukwila( L., (206) 431-3e70 Community Development % Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M99 -0221 Type: B -MECH Category: NRES Address: 17035 WEST VALLEY HY Location: Parcel #: 252304-9010 Contractor License No: MECHANICAL PERMIT TENANT NC MACHINERY 17035 WEST VALLEY HY, TUKWILA WA 98188 OWNER NC MACHINERY CO 16711 WEST VALLEY HY, TUKWILA WA 98188 CONTACT MIKE LEHEY 727 S KENYON, SEATTLE WA 98108 ******************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: INSTALL 1 PACKAGE ROOFTOP HVAC UNIT`& 3 EXHAUST FANS UMC Edition: 1997 Valuation:. Total Permit Fee: ******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Signature: Print Name:_ qe2vd4„ 1\--tq-cict Permit Centei/Authorized Signature Date Status: ISSUED Issued: 11/19/1999 Expires: 05/17/2000 Phone: Date: f// Phone: 206 -763 -1777 12,000.00 87.00 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the per ormanc of work. I am authorized to sign for and obtain this bui di = p, mit. _g N'0:5 Title: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. CITY OF TUKWILA Address: 37035 WEST VALLEY HY Permit No: M99-0221 Suite: Tenant: NC MACHINERY Status: ISSUED Type: F3-MECH Applied: 11/08/1999 Parcel it: 252304-9010 Issued: 11/19/1999 *************************************************************************** Permit Conditions: 1. No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 2 All permits, inspection records, and approved plans shell be available at the job site prior to the start of any con- struction. These documents are to be maintained and avail- able until final inspection approval 'is granted. 3. All construction to be done in conformance with approved plans and requirements of the Ulniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code ,(1997 Edition). 4. Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall riot be con strued to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any ; other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 5 . Menu f ac turers I nstal lat i on i nstruct i ohs requ i red on s i te for the build ing inspectors rev i ew Project Name/Tenant: C �� ^� /�� ML- ly al f Mechanical E uipment: 7 t o 0 DDS �.— 9 City Site Address : �i _ 17 wiry To K.G..., l ct, AAA, . 9 166 Tax Parcel Number: Property Owner: / A) Cam. Ath -.N. 4Q bin Phone: ( ) Street ddrys • City State/Zip: / tle. !, l ,17,,i y, ClL�Z let ult., q vi T Fax #: ( ) Phone: (.2o6, )7'5.. f7/75,- Fax it: ( Contractor: € iet ?U 1tp11 .(Gt9-A I t bA.l tit C t Phone: (.- ) 76'3-< 7lL' Street Address: City Sta t Zip: 7 -29-- - s . tee 1... ye.)^ gem N tAi,,, ,_ aiab Fax #: ( ) e , Contact Person: Phone: (-24.>G-.) ?ii. '.1---/ x Street Adds 5 , le Yell w�. Q I C � tyitate/Zip: �l`` tl'1- cc t 6 Fax /I: ( ) BUILDING OW R O t:1THORIZED AGENT: Signature: c � Date:7,�g/ Print name: _. 1 Phone: (.2o6, )7'5.. f7/75,- Fax it: ( ) Address: 72:7_, S- 41, u.yo Cit / State/Zip: . 5... a ,.14 , , 9 VQZ' CITY OF TUKWILA Permit Cent... 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 FOR STAFF USE ONLY Project 1 ..,nber: Permit Number. La: Milli? Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. MECHANICAL PERMIT REVIEW. AND' APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT). ; Description of work to be done (please be specific): � � / 7 L �C) Rtc:�nG,� /&Prop >9Gf at/ try.. C ) Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review • Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. 11/2/99 ,,,ech nernadoc ✓ Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 . H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. RESIDENTIAL: Two complete sets of attachments required with application submittal Submittal Requirements New Single Family Residence Heat loss calculations or Form H -6. Equipment specifications. Change - out or replacement of existing mechanical equipment Narrative of work to be done, including modification to duct work. Installation of Gas Fireplace Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the condition. chimney is in safe 11 /2 /'J'') nilrcpusi,doc • NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please heaters or vents being installed or replaced, �K�1 •S C �< < t1 1 ., include any water ^,,• 0 II * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * CITY OF WA V) TRANSMIT ************************** ********************************** TRANSMIT Number: R9800191 Amount: 87.00 11/19/99 09:43 Payment Method: CHECK Notation: EVERGREEN REFRIG 'nit: TLEL. Permit No: M99-0221 Type: B-MECH MECHANICAL. PERMIT Parcel No: 252304-9010 ,.` Site Address: 17035 WEST VALLEY HY Total Fees: /87.00 This Payment 87.00 Total ALL Pmts: i87.00 Balance: .00 **************************************************************** Account. Code Description Amount 000/345.830. PLAN CHECK - NONRES 17.40 000/322.100 MECHANICAL - NONRES 69.60 8980 11/22 9710 TOTL 87.00 Project f M .f C4, 7e4 Type of Inspection: i-- d" Address: .....,4/..,74,4.6 Da Special instructions: // r00 / : Date wanted: �m� - -13- - C : Requester: Phone: INSPECTIOM NO. ()Approved per applicable codes. COMMENTS: Inspector: Receipt No: INSPECTION RECOR' - Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 Corrections required prior to approval. Date: / "(J $47.00 REINSPECTION REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: PERMIT NO. (206)431 -3670 P,rpj�fjt. �` Type of l s e I n• A }e�s� ad t4, / ,Date called: / Special instructions: Date wanted: 6 /o': Requester: ` 1 CP 4cf 7 Phone: r9 e1) —, 7r/3 .. 7,t+t- ` 1 .,,"^, r{fyr - r -- 7 - : s t , ;"' ! "4""Y. Ni.;;:.!j ", INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 Approved per applicable codes. INSPECTION RECOR Retain a copy with permit PERMIT NO. (200431 -3670 Corrections required prior to approval. COMMENTS: ( i ce )\ 64 fe- it • . $47. i i EINSPECTI FIE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Proje: A , (1_,\‘‘ L . M It\AL. k 1 k 0 Type Of Invection: se k\ Nck C\ ' A dress: Date called: Special insiru 11 0% Date wanted: n ,-.. a.m. a\-44 p.m. Requester: n 1 lArirt Nin , Phone: An Le 1 MO ra?)14 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #190, Tukwila, WA 98188 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431-3670 Corrections required prior to approval., COMMENTS: s ovq.dft/4 Inspector: Date: /2 1:1 $47.00 REINSPECTIO EE REQUIRED. Prior to Inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Pro'e h mach Type o pVeraFI: -, Li c " , ' , "" ' 7 e036 t / . V Date called: J i /? / Special instructions: Date wanted: / L. . `" Requester: ' Phone � � /7W INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION INSPECTION RECO Retain a copy with permit PERMIT NO. 6300 Southcenter Blvd, #100, Tukwila, WA 98188 _(206)x431 -3670 i/ R O Approved per applicable codes. El Corrections required prior to approval. COMMENTS: (4 ; s.4.4 0`1 4 / c %'C 7 L - .c.. ./_.. J-lI El $47.00 REINSPECTION REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: r.qopeg 0.ft*, PV4S, , ' „ • , . ' 1 t •C IP f , t ‘701100!""•304P6W " • 4 _4 44 • "• ^ "• 4. ' • ' • — (.1. •• • ,;„ t",;.„s..t ,• •.• tf, a' •:aj.,G • ' ••• Sprinklers: • .• •. , 4 Ha : • • Monitor :if • ••• , Authorized Signatur:. 'INALAPP .FRM Aftiat•I . , . 4 4 . • :',...;!::4;;;K.;:‘ TUKWILA FIRE I. DEPARTMENT , FINAL 4 1 APPROVAL FORM 2/19/98 • Un dn ,,rh,r Vfr tl,i n. d444M Pai.1%;PiCit: Yt OR/ER. • . Vohn Rants,. Mayor'' omas P. ne e;Ftre•Chte Oi Permit No V - VI—. 09.43 4. • . • , li Stlite:.# '. ,..4:::,;,•;.,.•.' . a — . " Date ••••••• ;'0 • T.F.D. • • . • .4•1% Phnno. 121)h) S7c..41111' Pay117?) •17O',. Project Info Project Address NC Machinery Model No. Date 11/5/99 SP' 17035 West Vally Hwy Flow Control For Building Dept. Use Erl -2 Tuokwila, Wa 98188 5 -90 Applicant Name: Evergreen Refrigeration Inc. . 5A Applicant Address: 727 S. Kenyon Street, Seattle, W► 98108 Applicant Phone: (206) 763 -1744 145 Fan Equipment Schedule Equip. ID Brand Name' Model No. CFM SP' HP /BHP Flow Control Location of Service Erl -2 BRWIN 5 -90 54 0.13 . 5A 600 RESTR001I Zr 3 BRO11N 314M0 145 0.13 .9A coNr R0051 Cooling Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btu/h Total CFM OSA CFM or Econo? SEER or EER IPLV Location POP -1 LENNOX 00816- 090 -200 92800 3000 600 0/9.0 160000 emir Heating Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btu/h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency POP -1 LENNOX 00516- 090 -200 160000 3000 600 200000 160000 80.000 1994 Washington State Nonresidential Energy Code Compliance Forms 1994 Washington State Nonresidential Energy Code Compliance Form June, 1995 Project Description Briefly describe mechanical system type and features. INSTALL 1 PACKAGE ROOFTOP HVAC UNIT, AND 3 EXHAUST FANS Compliance Option Q Simple System 0 Complex System O Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information Is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill In the required information below. M99-O22 Prepared by Evergreen Refrigeration Inc. 11/5/99 RECEIVED CITY OF TUKWILA NOV - 8 1999 PERMIT CENTER System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: ❑ Constant vol? ❑ Split system? ❑ Air cooled? ❑ Packaged sys? ❑ Economizer Included? ❑ <54,000 Btuh or 1900 cfm? If Heating Only: ❑ <5000 cfm? ❑ <70% outside air? Heating Only no no ! 1994 Washligton State Nonresidential Energy Code Compliance Form Mechanical Summar . back) MECH -SUM Decision flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. <70% OA System Type <5000 cfm? yes or Cooling Only Reference ` Sec. 1421 54,000 Btuh 1900 cfm ackage stem Econo `Included? Reference no yes Sec. 1423 onstan olume Ir Cooled? Split tern 54,000 Btu 1900 cfm eatine Coolin 4 Simple System Allowed Reference Sec. 1420 r Use Complex System Reference Sec. 1430 RECEIVED %XIV OF TUKWILA NOV - 8 1999 PERMIT CENTER Mechanical Permit 1994 Washington State Energy Code Plans Checklist Compliance Forms MECH -CHK June, 1995 Project Address NC Machinery I Date 11/5/99 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, (yes, no, n.a.) Section Com Went Component Information Re ulred Required I Location I on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance n. a. 1411.4 Pkg. elec. htg.8 cig. List heat pumps on schedule yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency 'Mi 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans Mi - yes 1412.2 Deadband control Indicate 5 degree deadband minimum Mi n. a. 1412.3 Humidity control Indicate humidistat yes 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types Mi yes 1412.4.1 Dampers Indicate damper location and automatic controls Mi n. a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule n. a. 1412.6 Combustion htg. Indicate modulating or staged control yes 1412.7 Balancing Indicate balancing features on plans Mi n. a. 1422 Thermostat interlock Indicate thermostat interlock on plans yes 1423 Economizers Equipment schedule Mi 1413 Air economizers yes 1413.1 Operation Indicate 100% capability on schedule Mi yes 1413.2 Control Indicate controls able to evaluate outside air Mi Yes 1413.3 Integrated operation Indicate capability for partial cooling Mi 1414 Ducting systems yes 1414.1 Duct sealing indicate sealing necessary Mi yes 1414.2 Duct insulation Indicate R -value of insulation on duct Mi n. a. 1415.1 Piping insulation Indicate R -value of Insulation on piping n. a. 1424 Separate air sys. Indicate separate systems on plans yes Mech. Sum. Form Completed and attached. Equipment schedule with types, Input/output, efficiency, cfm, hp, economizer 1994 Wash piton State Nonresidential Energy Code Compli nce Form Prepared by Evergreen Refrigeration Inc. 11/5/99 CITY OF TUKWILA NOV - 8 1999 PERMIT CENTER 1994 Washi aton State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist MECH -CHK 1994 Washington State Energy Code Compliance Forms Mechanical - General Requirements 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum, Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off; HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven-day clock and be capable of being set for seven different day types per week, Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu/h) or less may controlled by readily accessible manual off - hour controls. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open dampers. These dampers shall remain closed in normal operation until activated by tho fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 1412.6 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set -up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. Exceptions: 1, Boilers. 2. Radiant Heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. 1413.2 Control: Air economizers shall be controlled by a control system capable of determining If outside air can meet part or all of the building's cooling loads. June, 1995 1413.3 Integrated Operation: Building Heating Energy: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Controls shall not preclude the economizer operation when mechanical cooling Is required simultaneously. Exception: Economizers on individual, direct expansion, cooling systems with capacities not greater than 75,000 Btu/h may include controls that limit simultaneous operation of the economizer and mechanical cooling for the purpose of preventing Ice formation on cooling coils. 1414 Ducting Systems 1414.1 Seating: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 Inches; seal transverse Joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. 1414.2 Insulation: Ducts and plenums that are constructed as part of the building envelope shall meet the requirements of Chapter 13. Other ducts and plenums shall be thermally insulated per Table 14 -5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a space that serves that space only. 1416 Piping Systems 1416.1 Insulation: Piping shall be thermally insulated in accordance with Table 14-6. Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1420 SIMPLE SYSTEMS (PACKAGED UNITARY EQUIPMENT) 1421 System Type: To qualify as a simple system, systems shall be one of the following: a. Air cooled, constant volume packaged equipment, which provide heating, cooling or both, and require only external connection to duct work and energy services. b. Air cooled, constant volume split systems, which provide heating, cooling or both, with cooling capacity of 54,000 Btu /h or less. c. Heating only systems which have a capacity of less than 5,000 cfm or which have a minimum outside air supply of less than 70 percent of the total air circulation. All other systems shall comply with Sections 1430 through 1438. 1422 Controls: In addition to the control requirements In Section 1412, where separate heating and cooling equipment serve the same temperature zone, thermostats shall be Interlocked to prevent simultaneous heating and cooling. 1423 Economizers: Economizers meeting the requirements of Section 1413 shall be installed on packaged roof top fan - cooling units having a supply capacity of greater than 1,900 dm or a total cooling capacity greater than 54,000 Btu/h. The total capacity of all units without economizers shall not exceed 240,000 Btu/h per building. 1424 Separate Air Distribution Systems: Zones with special process temperature requirements and/or humidity requirements shall be served by separate air distribution systems from those serving zones requiring only comfort conditions. Prepared by Evergreen Refrigeration Inc. 11/5/99 RECEIVED CITY OF TC)1(0 NOV - 8 1999 PERMIT CENTER ACTIVITY NUMBER: M99 - 0221 DATE: 11 - - PROJECT NAME: N. C. MACHINERY XX Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # — Revision # __After Permit Is Issued DEPARTMENTS: Buil•i Division Q 11 - "t' J lib Works WRROUTE,DOC 5/99 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP TB .(, DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Approved n Approved with Conditions 6-lo Fire Prevention A1,0 11 Structural n Permit Coordinator Planning Division DUE DATE: 11-9-99 Complete a Incomplete n Not Applicable Comments: TUES /THURS ROUTI G: Please Route Structural Review Required El No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE 12 -7 -99 Approved n Approved with Conditions' Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE n 91 C Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: C. City of Tukwila Fire Department Fire Department Review Control #M99 -0221 (510) Re: N.C. Machinery - 17025 West Valley Highway Dear Sir: November 10, 1999 Thomas P. Keefe, Fire Chief The attached set of mechanical plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1742) H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildin ?s shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2)) Duct smoke detectors shall be capable of being reset from the alarm panel. (City Ordinance #1742) All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been John W. Rants, Mayor hlvailm,artorc ("tatlnn. AAA Andnuor P Vac'. • T» l udla Wachinotnn 01111211 a Dhnn.,. 10111 C7CAA/IA . Env,. /0/IAI C7CAA4n Yours truly, City of Tukwila Fire Department Page number obtained. (City Ordinance #1742) (UFC 1001.3) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) Any overlooked hazardous condition and /or violation of the adopted Fire or.Building Codes does not imply approval of such condition or violation. The Tukwila Fire Prevention Bureau cc: TFD file ncd 51� John W. Rants, Mayor Thomas P. Keefe, Fire Chief • Ds..u...._ AAA A T. 111...11410.;14...... not oo fl1. ...'MRiU eve_ AAA eoa.I flAI C7[_ 420 Nov 19 99 10:29a Evergreen Refrigeration 206 763 2389 DEPARTMENT OF LABOR AND INDUSTRIES ! F625-052-000 (NW) • NATURESAVER MEMO 01616 To CoiDept, . I P hone Fax I id pages I 10 r Date From pit Mme Fax I I “."'"""- WachAndOlsinnyCeEMMni. REGISTERED AS PROVIDED BY LAW AS CONST CONT SPECIALTY REGIST. # EXP. DATE CCAAAB EVERGI*201D7 07/31/2000 EFFECTIVE DATE . 03/27/1980 EVERGREEN REFRIGERATION INC 727 S KENYON SEATTLE WA 98108 hi,ich And l'hylay Cernilehle ••. • pt fA -7-cmAc-*--p;iL v■f, • • • • P • 1 SYMBOL LEGEND SYMBOL ABBY. DESCRIPTION H AIRFLOW DUCT SECTION SLPPLY MIN. OSA, COOLING DUCT SECTION - REfLRN /EXHAUST ff WEIGHT', RECTANfiJLAR DUCT - 2 p , — --- TOTAL ROUND DUCT .\/\ INPUT FLDCBLE DUCT AFUE VD VOLUME DAMPER L.C.A. MAX FUSE ZD ZONE DAMPER °�— TOTAL MD MOTORIZED DAMPER --. FD FRE(DAMPEt PSC. .._ „vIJ II ,'. ._� .. ' , ^ 6 r, 1 16 1, 15fibrigav romeaSREW _".J . — - Ipl _ - i BTUH i does not tut :.CfR9 the Vloiason Calsi , TIOiV DAMPER . '�d COdy p1 Ord1nB11liE. RBGaPt I@ 50 SM10IE-DET£t, albt0Y111/d000 Q T LBS TFERNOSGXTC Q 5 Dots 7 ,,,,, - -_R_ - R__ - R !)it, 0.�.3.y1 `.' F'CY-,6tvnQP _ -_6 - -G- -- G NIATLRAL 6. LIxES Ea : CELNG DV 61.,PLY) 208 -230 30 GELJIVG DFFUSER O:ETLRWEXHAI 50 - 875 I SS EXHAUST, FAN (CO2' MOUNTED) C ol 1042 1,,E FAN A T PROPELLER FAN CH- :.'' al., L ,1„.. SDEWALL DFFUSEZ / /. Y .ECT;;Ic; AL ..... DUCT FTTNG UCVi' Nlra 80..1 12' 2 .. ., DATLM -... L 1T TAG r_..... .._..__ 0 • -' . DUCT RISER GAS PACKAGE EQUIPMENT SCHEDULE MARK MANF. MODEL TONS. AIRFLOW 'SP MIN. OSA, COOLING HEATING ELECTRICAL WEIGHT', CFM INS CFM TOTAL SEER EEEU INPUT OUTPUT AFUE VOLTS PHASE L.C.A. MAX FUSE UNBT ECON OSA DPR ',CURB TOTAL BTUH BTUH BTUH ( %) (V) (A) LBS _LBS LBS LBS LBS PGP I LENNOX 60516- 090 -200 7.5 3000 0.5' 600 92,800 - -- 9.0 200,000 160,000' 80 208 -230 30 42 50 - 875 I SS -- 107 1042 EXHAUST FAN SCHEDULE MARK MANF. /MODEL OEM S.P. VOLTS HP /Amps PHASE NOTES EF 12 : GROAN 5 40 €/8' I5 as A i Located on ceiling EF 3 GROAN 314M6 145 I /B' &5 Oa A i Located on ceiling DIMENSIONS INCHES (MM) Basic Unit With EMDH16M (Horizontal) Economizer Damper Section & RMF16 Roof Mounting Frame CORNER WEIGHTS AA lbs. kg 235 107 294 1,33 B8 lbs. 273 329 kg 124 149 Motlel Number GCS16 -090 GCS16 -120 SITE PLAN SCALE NONE TOP VIEW OPENI.NGT EMIDHI6M (254) r Famahetl00OGEDtfi _ G erlly Exhaust O mparel CENTER OF GRAVITY Model Number GCS16 -090 GCS16 -120 CONDENSER COIL FAN (dual Fane On 13oj eLs inch 24 -1/2 34 EE 622 864 Inch 43-1/2 FF CONDENSER SECTION END VIEW 041 1105 = SU PACT 4 • 4 1 IIIJJJ J C LLLIII J FI TEP 26- 3/A__� � ❑ < ♦ I- -- - I6B4, �; 111111 l I i\I �OUTADOOfl DAD AIR \II. Ill. 1 1 1 1 I D IR \ EWES �!' \ ; \ \' FI(TERS I H H F I. I \( II'I it I I.!i ) L - AIA_ I IIII : \� I Illy' 1 -1/2 P L fl I 1;1 D (36j IN DAIAPEAS OPTIONAL GEDI6 DAMPER GRAVITY E %HAUSTDAMPERS MOTOA (Fivlo inaielieuj Model No. GCS16-090 II 88 -1/2 GCS16 -120 98 2489 48 60 mm In 1219 39 TM 2248 1524 48 991 1168 13 -1/4 19 -1/4 MM 337 489 19 -7/16 25 -1 /4 mm n. 494 32 -1/2 816 641 39 - 1/8 1 994 1 -5/8 MT In. 28 -3/4 34 -3/4 41 730 883 DIMENSIONS - INCHES OHM) Basic Unit CORNER WEIGHTS AA lbs. kg 236 107 276 125 BB lbs. 283 311 kg 128 141 Modal Number GCS16 -090 GCS. 120 INDUCEDDRAFT oLOWEo OPTIONAL LUENEETNT eOTTOMPOWEfl FAA. ENniY KR rl fifllifRlP F m.O 1111111111111. 111111111 11lr OF G ' v1rv�� E %CNANGEfl)I EVAPOP TOO I r` III11111111I,..� FK 66s E. I �i Ul)llt1U' ®ism TOP VIEW A CC lbs. kg 193 88 268 122 OD lbs. kg 162 245 JUAN EN1RN AI OPENUIG 93 jj (B3B) -} 1- 1/2(38) T 1- 12 BACK VIEW WITH HORIZONTAL SUPPLY 8 RETURN AIR OPENING 69 111 CC CONDENSER COIL FAN CENTER OF GRAVITY Motlel Number GCS16 -090 GCS16-120 Inch 28 -1/2 37 EE -1/1 31/1 TT 724 940 Men 40 43-1/2 TOP VIEW BASE SECTION FRONT VIEW i6Efl COIL 1 COMPRESSORS (2) CONDENSER SECTION END VIEW FF 1016 1105 Model No. GCS16 -090 GC516.120 A In. 88 -1/2 2248 48 1219 39 991 16 -1/2 419 24 -5/8 625 in. MT 19 - 7/16 494 32 - 1/2 816 98 2/89 60 1524 46 1168 24 610 31 - 5/8 803 25 641 39 994 Mode/ No. GCS16 -090 GCS16 -120 In. mm in. mm In. mm In. mm In. mm 'In. mm In. mm 1 -5/8 41 5 -5/8 143 II 2 I 51 4 -7/16 j 113 25 31 -118 635, 791 54 -1/2 57 -12 1384 1461 64 -7/8 68 1648 1727 22 -1/8 28 -1/2 562 724 9 -3/4 14 248 356 GENERAL NOTES DUCTWORK ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2' TO EACH DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 470 EACH DIMENSION IF DUCTWORK 15 ON THE EXTERIOR OF BUILDING. THE FIRST NUMBER ON ALL DUCT DIMENSIONS 15 THE WIDTH AND THE SECOND NUMBER 15 THE HEIGHT. MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT RATNG LESS THAN 50, PER UMC 1997, SEC.601.4. SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN I/O INCHES AND 2 INCHES. DUCTWORK WHICH 15 DESIGNED TO OPERATE AT PRESSURES ABOVE I/Z INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD R5 -15. L5 ALL DUCT GAUGES PER TABLE 6 - A 4 TABLE 6 -B OF 1987 UMC. I.b ALL DUCT SUPPORTS PER TABLE 6 -E OF 1887 UMC. 1.7 ATTACH DIFFUSERS AND GRILLES TO T 3AR GRID PER GODE5. LB BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. DUCT INSULATION 2.1 INSULATE OR LINE DUCTWORK PER WA. STATE ENERGY AND MECHANICAL CODES. GENERAL CONTRACTOR 3.1 GENERAL CONTRACTOR TO PROVIDE AND CUT OPENINGS FOR ALL ROOFTOP, CEILING, FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING AND FIRE PROOF LINING PER U.M.G. 3.2 GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATION AND DIMENSIONS WITH ERI BEFORE FRAMING OPENINGS. 3.3 GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING A5 REQUIRED FOR MECHANICAL WORK. 3.4 GENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS REQUIRED FOR MECHANICAL WORK. 35 GENERAL CONTACTOR TO PROVIDE ADEQUATE ENGINEERING AS REQUIRED FOR MEGHANIGAL WORK. 3, GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL EQUIPMENT. 3.7 GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY ERI, PROVIDE ALL GANT STRIPS AND CURB INSULATION, AND SEAL AGAINST LEAKS. 3.B GENERAL CONTRACTOR TO PROVIDE ALL CUTTING AND PATCHING OF T -BAR CEILING AS REQUIRED FOR HVAC INSTALLATION. 3.9 GENERAL CONTRACTOR TO PROTECT ALL OPENINGS THROUGH FLOORS PROVIDED FOR DUCTWORK INSTALLATION IN ACCORDANCE WITH TABLE 6A OF UNIFORM BUILDING CODE (1997 EDITION). WHERE REQUIRED BY SECTION 711 OF UDC 11997). ELECTRICAL 4.1' ERI TO INSTALL ALL LOW VOLTAGE CONTROL WIRING, CONDUIT WILL BE PROVIDED BY ELECTRICAL CONTRACTOR. 4.2 ELECTRICAL CONTRACTOR TO PROVIDE ALL. ELECTRICAL CONNECTIONS, DISCONNECTS, AND ZTARTERS FOR MECHANICAL EQUIPMENT, 43' ELECTRICAL., CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS. AND LOCATIONS WITH ERI MECHANICAL. PLAN AND WITH FIELD' CONDITIONS. 4.4 ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM' EXHAUST FANS WITH LIGHT SWITCH. 4.5' ERI TO PROVIDE 7 -DAY NIGHT SETBACK PROGRAMMABLE TYPE T -STAT WITH CAPABILITY OF 5T DEADBAND. 4.6 ERI TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER. PLUMBING 5.1 PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL GAS PIPING FOR MEGHANIGAL EQUIPMENT PER CODE. 5.2 PLUMBING CONTRACTOR OFFSET VENTS 10 FEET MINIMUM FROM ALL HVAC FRESH AIR INTAKES OR 3' ABOVE HIGHEST POINT OF INTAKE. 5.3 CONDENSATE DRAINS AND DRAIN LINES BY ERI., DRAIN TO ROOF WITHIN IV OF UNITS. ENERGY CODE COMPLIANCE Si AT A MINIMUM, 'EACH FLOOR I TO BE CONSIDERED A SEPERATE ZONE. VERIFY THERMOSTATIC CONTROL FO E ACH ZONE A5 INDICATED ON PLANS. 6.2 OUTSIDE AIR INTAKES, EXHAUST OUTLETS, AND RELIEF OUTLETS SERVING CONDITIONED SPACES SHALL BE EQUIPS WITH DAMPERS WHICH CLOSE AUTOMATICALLY WHEN THE SYSTEM 15 OFF OR UPON POWER FAILURE, PER WSEG SEC. 1412.4.1. AIR ECONOMISE WHERE .REQUIRED. BY CODE ARE INDICATED BY THE EQUIPMENT SCHEDULE AT DO% CAPABILITY, CONTROL AND OPERATION OF THE ECONOMISER SHALL GOMPLI' WITH WSEG. SEC. 1423. MECHANICAL COP_ COMPLIANCE 7J WHERE REQUIRED PROVIDE AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS IN EACH SYSTEM DELIVERING HEATING OR COOLING A IN EXCESS OF 2000 CFM. DETECTORS SHALL BE LOCATED IN THE MAIN SUPPLY AIR PER UMC M97 SEG. 608. AI AM INV MP W W W W I- I- I- I- B < < < O 0 DRAWING DATE: Machm9 M ■RECEIVE CI OF TI I - JILA 0y 1999 PERMIT CENTER 3 3 z EVERGI201D7 0 a z 0 a m EVERGREEN REFRIGERATION, INC. 727 SOUTH KENYON z 0 D m m 0 z HVAC PLAN NC MACHINERY 17035 WEST VALLEY HWY TLJKWILA, WASHINGTON 98188 SEATTLE, WASHINGTON 98108 (208) 788 - 1744 FAX (206) 783 - 2389 PROGRESS PRINTS - NOT FOR CONSTRUCTION DATE' a -o&-va ❑ APPROVED FINAL DRAWINGS DATE' • CONSTRUCTION DRAWINGS DATE: ❑ AS BUILT DRAWINGS DATE' EVERGI201D7 NC MACHINERY ELEVATIONS 17035 WEST VALLEY HWY TUKWILA, WASHINGTON 98188 PROGRESS PRINTS - NOT FOR CONSTRUCTION DATE: 10-06 -99 APPROVED FINAL DRAWINGS DATE' ❑ CONSTRUCTION DRAWINGS DATE: ❑ AS BUILT DRAWINGS DATE: EVERGREEN REFRIGERATION INC 727 SOUTH KENYON SEATTLE, WASHINGTON 98108 z 0 (208) 789 1744 FAX (206) 783 - 2389