Permit No: M99 -0221
Type: B -MECH
Category: NRES
Address: 17035 WEST VALLEY HY
Location:
Parcel #: 252304-9010
Contractor License No:
MECHANICAL PERMIT
TENANT NC MACHINERY
17035 WEST VALLEY HY, TUKWILA WA 98188
OWNER NC MACHINERY CO
16711 WEST VALLEY HY, TUKWILA WA 98188
CONTACT MIKE LEHEY
727 S KENYON, SEATTLE WA 98108
******************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Permit Description:
INSTALL 1 PACKAGE ROOFTOP HVAC UNIT`& 3
EXHAUST FANS
UMC Edition: 1997
Valuation:.
Total Permit Fee:
******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Signature:
Print Name:_
qe2vd4„ 1\--tq-cict
Permit Centei/Authorized Signature Date
Status: ISSUED
Issued: 11/19/1999
Expires: 05/17/2000
Phone:
Date: f//
Phone: 206 -763 -1777
12,000.00
87.00
I hereby certify that I have read and examined this permit and know the
same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate
or cancel the provisions of any other state or local laws regulating
construction or the per ormanc of work. I am authorized to sign for and
obtain this bui di = p, mit.
_g N'0:5 Title:
This permit shall become null and void if the work is not commenced within
180 days from the date of issuance, or if the work is suspended or
abandoned for a period of 180 days from the last inspection.
CITY OF TUKWILA
Address: 37035 WEST VALLEY HY Permit No: M99-0221
Suite:
Tenant: NC MACHINERY Status: ISSUED
Type: F3-MECH Applied: 11/08/1999
Parcel it: 252304-9010 Issued: 11/19/1999
***************************************************************************
Permit Conditions:
1. No changes will be made to the plans unless approved by the
Engineer and the Tukwila Building Division.
2 All permits, inspection records, and approved plans shell be
available at the job site prior to the start of any con-
struction. These documents are to be maintained and avail-
able until final inspection approval 'is granted.
3. All construction to be done in conformance with approved
plans and requirements of the Ulniform Building Code (1997
Edition) as amended, Uniform Mechanical Code (1997 Edition),
and Washington State Energy Code ,(1997 Edition).
4. Validity of Permit. The issuance of a permit or approval of
plans, specifications, and computations shall riot be con
strued to be a permit for, or an approval of, any violation
of any of the provisions of the building code or of any ;
other ordinance of the jurisdiction. No permit presuming to
give authority to violate or cancel the provisions of this
code shall be valid.
5 . Menu f ac turers I nstal lat i on i nstruct i ohs requ i red on s i te
for the build ing inspectors rev i ew
Project Name/Tenant: C �� ^� /��
ML-
ly al f Mechanical E uipment:
7 t o 0 DDS �.— 9
City
Site Address : �i _
17 wiry To K.G..., l ct, AAA, . 9 166
Tax Parcel Number:
Property Owner: /
A) Cam. Ath -.N. 4Q bin
Phone: ( )
Street ddrys • City State/Zip:
/ tle. !, l ,17,,i y, ClL�Z let ult., q vi T
Fax #: ( )
Phone: (.2o6, )7'5.. f7/75,- Fax it: (
Contractor:
€ iet ?U 1tp11 .(Gt9-A I t bA.l tit C t
Phone: (.- ) 76'3-<
7lL'
Street Address: City Sta t Zip:
7 -29-- - s . tee 1... ye.)^ gem N tAi,,, ,_ aiab
Fax #: ( )
e ,
Contact Person:
Phone: (-24.>G-.) ?ii. '.1---/
x
Street Adds 5 , le Yell w�. Q I C � tyitate/Zip:
�l`` tl'1- cc t 6
Fax /I: ( )
BUILDING OW R O t:1THORIZED AGENT:
Signature: c �
Date:7,�g/
Print name: _.
1
Phone: (.2o6, )7'5.. f7/75,- Fax it: (
)
Address: 72:7_, S- 41, u.yo
Cit / State/Zip: . 5... a ,.14 , , 9 VQZ'
CITY OF TUKWILA
Permit Cent...
6300 Southcenter Boulevard, Suite 100
Tukwila, WA 98188
(206) 431 -3670
FOR STAFF USE ONLY
Project 1 ..,nber:
Permit Number.
La: Milli?
Mechanical Permit Application
Application and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or facsimile.
MECHANICAL PERMIT REVIEW. AND' APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT). ;
Description of work to be done (please be specific): � �
/ 7 L �C) Rtc:�nG,� /&Prop >9Gf at/ try.. C )
Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of
application, a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor
Registration ".
Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the
State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the
permit will be required as part of this submittal.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
Expiration of Plan Review • Applications for which no permit is issued within 180 days following the date of application shall expire by
limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written
request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be
extended more than once.
11/2/99
,,,ech nernadoc
✓
Submittal Requirements
Floor plan and system layout
Roof plan required to identify individual equipment and the location of each installation (Uniform
Mechanical Code 504 (e))
Details and elevations (for roof mounted equipment) and proposed screening
Heat Loss Calculations or Washington State Energy Code Form #H -7
.
H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut-
off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical
Code 1009).
Specifications must be provided to show that replacement equipment complies with the efficiency ratings
and other applicable requirements of the Washington State Nonresidential Energy Code.
Structural engineer's analysis is required for new and the replacement of existing roof equipment
weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be
stamped by a Washington State licensed Structural Engineer.
Mechanical Permits
COMMERCIAL: Two complete sets of drawings and attachments required with application submittal
NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water
heaters or vents being installed or replaced.
RESIDENTIAL: Two complete sets of attachments required with application submittal
Submittal Requirements
New Single Family Residence
Heat loss calculations or Form H -6.
Equipment specifications.
Change - out or replacement of existing mechanical equipment
Narrative of work to be done, including modification to duct work.
Installation of Gas Fireplace
Narrative with specification of equipment and chimney type.
If using existing chimney, provide a letter by a certified chimney sweep stating that the
condition.
chimney is in safe
11 /2 /'J'')
nilrcpusi,doc •
NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please
heaters or vents being installed or replaced,
�K�1 •S C �< < t1 1 .,
include any water
^,,•
0
II
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
CITY OF WA V) TRANSMIT
************************** **********************************
TRANSMIT Number: R9800191 Amount: 87.00 11/19/99 09:43
Payment Method: CHECK Notation: EVERGREEN REFRIG 'nit: TLEL.
Permit No: M99-0221 Type: B-MECH MECHANICAL. PERMIT
Parcel No: 252304-9010
,.`
Site Address: 17035 WEST VALLEY HY
Total Fees: /87.00
This Payment 87.00 Total ALL Pmts: i87.00
Balance: .00
****************************************************************
Account. Code Description Amount
000/345.830. PLAN CHECK - NONRES 17.40
000/322.100 MECHANICAL - NONRES 69.60
8980 11/22 9710 TOTL 87.00
Project
f M .f C4, 7e4
Type of Inspection:
i-- d"
Address:
.....,4/..,74,4.6
Da
Special instructions:
// r00
/
: Date wanted:
�m�
- -13- - C :
Requester:
Phone:
INSPECTIOM NO.
()Approved per applicable codes.
COMMENTS:
Inspector:
Receipt No:
INSPECTION RECOR' -
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd, #100, Tukwila, WA 9818
Corrections required prior to approval.
Date: / "(J
$47.00 REINSPECTION REQUIRED. Prior to inspection, fee must be paid
at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Date:
PERMIT NO.
(206)431 -3670
P,rpj�fjt.
�`
Type of l s e
I n•
A }e�s�
ad t4, /
,Date called:
/
Special instructions:
Date wanted:
6 /o':
Requester:
` 1 CP 4cf 7
Phone:
r9 e1)
—, 7r/3
.. 7,t+t- ` 1 .,,"^, r{fyr - r -- 7 - : s t , ;"' ! "4""Y. Ni.;;:.!j ",
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd, #100, Tukwila, WA 9818
Approved per applicable codes.
INSPECTION RECOR
Retain a copy with permit
PERMIT NO.
(200431 -3670
Corrections required prior to approval.
COMMENTS:
( i ce )\ 64 fe-
it • .
$47. i i EINSPECTI FIE REQUIRED. Prior to inspection, fee must be paid
at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No:
Date:
Proje: A , (1_,\‘‘ L . M
It\AL. k 1 k 0
Type Of Invection:
se k\ Nck C\ '
A dress:
Date called:
Special insiru
11 0%
Date wanted: n ,-.. a.m.
a\-44 p.m.
Requester: n 1
lArirt Nin ,
Phone:
An Le 1 MO ra?)14
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd, #190, Tukwila, WA 98188
Approved per applicable codes.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
(206)431-3670
Corrections required prior to approval.,
COMMENTS:
s ovq.dft/4
Inspector:
Date: /2
1:1 $47.00 REINSPECTIO EE REQUIRED. Prior to Inspection, fee must be paid
at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No:
Date:
Pro'e h mach
Type o pVeraFI: -, Li c " , ' , "" '
7 e036 t / . V
Date called:
J i /?
/
Special instructions:
Date wanted:
/ L. .
`"
Requester:
'
Phone
� � /7W
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
INSPECTION RECO
Retain a copy with permit
PERMIT NO.
6300 Southcenter Blvd, #100, Tukwila, WA 98188 _(206)x431 -3670 i/ R
O Approved per applicable codes. El Corrections required prior to approval.
COMMENTS:
(4 ; s.4.4
0`1 4 / c %'C 7 L -
.c.. ./_.. J-lI
El $47.00 REINSPECTION REQUIRED. Prior to inspection, fee must be paid
at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No:
Date:
r.qopeg 0.ft*, PV4S,
, ' „ • , . ' 1 t •C IP f , t ‘701100!""•304P6W " •
4 _4 44
• "• ^ "•
4. ' • ' •
— (.1.
••
• ,;„ t",;.„s..t
,• •.• tf, a' •:aj.,G •
' ••• Sprinklers: •
.• •. ,
4 Ha :
• • Monitor :if
•
•••
, Authorized Signatur:.
'INALAPP .FRM
Aftiat•I
. , . 4 4 . • :',...;!::4;;;K.;:‘
TUKWILA FIRE I. DEPARTMENT ,
FINAL 4 1 APPROVAL FORM
2/19/98
•
Un dn ,,rh,r Vfr tl,i n. d444M Pai.1%;PiCit: Yt OR/ER.
• .
Vohn Rants,. Mayor''
omas P. ne e;Ftre•Chte
Oi
Permit No V - VI—. 09.43
4. •
. • ,
li Stlite:.# '. ,..4:::,;,•;.,.•.'
. a
— . "
Date
••••••• ;'0 •
T.F.D.
•
• . • .4•1%
Phnno. 121)h) S7c..41111' Pay117?) •17O',.
Project Info
Project Address
NC Machinery
Model No.
Date 11/5/99
SP'
17035 West Vally Hwy
Flow Control
For Building Dept. Use
Erl -2
Tuokwila, Wa 98188
5 -90
Applicant Name:
Evergreen Refrigeration Inc.
. 5A
Applicant Address:
727 S. Kenyon Street, Seattle,
W► 98108
Applicant Phone:
(206) 763 -1744
145
Fan Equipment Schedule
Equip.
ID
Brand Name'
Model No.
CFM
SP'
HP /BHP
Flow Control
Location of Service
Erl -2
BRWIN
5 -90
54
0.13
. 5A
600
RESTR001I
Zr 3
BRO11N
314M0
145
0.13
.9A
coNr R0051
Cooling Equipment Schedule
Equip.
ID
Brand Name'
Model No.
Capacity
Btu/h
Total CFM
OSA CFM
or Econo?
SEER
or EER
IPLV
Location
POP -1
LENNOX
00816- 090 -200
92800
3000
600
0/9.0
160000
emir
Heating Equipment Schedule
Equip.
ID
Brand Name'
Model No.
Capacity
Btu/h
Total CFM
OSA cfm
or Econo?
Input Btuh
Output Btuh
Efficiency
POP -1
LENNOX
00516- 090 -200
160000
3000
600
200000
160000
80.000
1994 Washington State Nonresidential Energy Code Compliance Forms
1994 Washington State Nonresidential Energy Code Compliance Form
June, 1995
Project Description
Briefly describe mechanical system
type and features.
INSTALL 1 PACKAGE ROOFTOP HVAC UNIT, AND 3 EXHAUST FANS
Compliance Option
Q Simple System 0 Complex System O Systems Analysis
(See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.)
Equipment Schedules
The following information Is required to be incorporated with the mechanical equipment schedules on the
plans. For projects without plans, fill In the required information below.
M99-O22
Prepared by Evergreen Refrigeration Inc. 11/5/99
RECEIVED
CITY OF TUKWILA
NOV - 8 1999
PERMIT CENTER
System Description
See Section 1421 for full description of
Simple System qualifications.
If Heating /Cooling
or Cooling Only:
❑ Constant vol?
❑ Split system?
❑ Air cooled? ❑ Packaged sys?
❑ Economizer Included?
❑ <54,000 Btuh
or 1900 cfm?
If Heating Only:
❑ <5000 cfm?
❑ <70% outside air?
Heating Only
no
no
!
1994 Washligton State Nonresidential Energy Code Compliance Form
Mechanical Summar . back)
MECH -SUM
Decision flowchart
Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex
System or Systems Analysis Options must be used.
<70% OA
System Type
<5000 cfm?
yes
or Cooling Only
Reference
` Sec. 1421
54,000 Btuh
1900 cfm
ackage
stem
Econo
`Included? Reference
no yes Sec. 1423
onstan
olume
Ir Cooled?
Split
tern
54,000 Btu
1900 cfm
eatine Coolin
4 Simple System
Allowed
Reference
Sec. 1420
r
Use Complex
System
Reference
Sec. 1430
RECEIVED
%XIV OF TUKWILA
NOV - 8 1999
PERMIT CENTER
Mechanical Permit
1994 Washington State Energy Code
Plans Checklist
Compliance Forms
MECH -CHK
June, 1995
Project Address NC Machinery
I Date 11/5/99
The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the
Washington State Nonresidential Energy Code.
Applicability
(yes,
(yes, no, n.a.)
Section
Com Went
Component
Information Re ulred
Required
I
Location I
on Plans
Building Department
Notes
HVAC REQUIREMENTS
(Sections 1401 -1424)
1411
Equipment performance
n. a.
1411.4
Pkg. elec. htg.8 cig.
List heat pumps on schedule
yes
1411.1
Minimum efficiency
Equipment schedule with type, capacity, efficiency
'Mi
1412
HVAC controls
yes
1412.1
Temperature zones
Indicate locations on plans
Mi
-
yes
1412.2
Deadband control
Indicate 5 degree deadband minimum
Mi
n. a.
1412.3
Humidity control
Indicate humidistat
yes
1412.4
Automatic setback
Indicate thermostat with night setback and 7 diff. day types
Mi
yes
1412.4.1
Dampers
Indicate damper location and automatic controls
Mi
n. a.
1412.5
Heat pump control
Indicate microprocessor on thermostat schedule
n. a.
1412.6
Combustion htg.
Indicate modulating or staged control
yes
1412.7
Balancing
Indicate balancing features on plans
Mi
n. a.
1422
Thermostat interlock
Indicate thermostat interlock on plans
yes
1423
Economizers
Equipment schedule
Mi
1413
Air economizers
yes
1413.1
Operation
Indicate 100% capability on schedule
Mi
yes
1413.2
Control
Indicate controls able to evaluate outside air
Mi
Yes
1413.3
Integrated operation
Indicate capability for partial cooling
Mi
1414
Ducting systems
yes
1414.1
Duct sealing
indicate sealing necessary
Mi
yes
1414.2
Duct insulation
Indicate R -value of insulation on duct
Mi
n. a.
1415.1
Piping insulation
Indicate R -value of Insulation on piping
n. a.
1424
Separate air sys.
Indicate separate systems on plans
yes
Mech. Sum. Form
Completed and attached. Equipment schedule with types,
Input/output, efficiency, cfm, hp, economizer
1994 Wash piton State Nonresidential Energy Code Compli nce Form
Prepared by Evergreen Refrigeration Inc. 11/5/99
CITY OF TUKWILA
NOV - 8 1999
PERMIT CENTER
1994 Washi
aton State Nonresidential Energy Code Compliance Form
Mechanical Permit Plans Checklist
MECH -CHK
1994
Washington State Energy Code Compliance Forms
Mechanical - General Requirements
1412 Controls
1412.1 Temperature Controls: Each system shall be provided with at
least one temperature control device. Each zone shall be controlled by
individual thermostatic controls responding to temperature within the zone.
At a minimum, each floor of a building shall be considered as a separate
zone.
1412.2 Deadband Controls: When used to control both comfort heating
and cooling, zone thermostatic controls shall be capable of a deadband of at
least 5 degrees F within which the supply of heating and cooling energy to
the zone is shut off or reduced to a minimum,
Exceptions:
1. Special occupancy, special usage, or code requirements where
deadband controls are not appropriate.
2. Buildings complying with Section 1141.4, if in the proposed
building energy analysis, heating and cooling
thermostat setpoints are set to the same temperature
between 70 degrees F and 75 degrees F inclusive,
and assumed to be constant throughout the year.
3. Thermostats that require manual changeover between heating
and cooling modes.
1412.3 Humidity Controls: If a system is equipped with a means for
adding moisture, a humidistat shall be provided.
1412.4 Setback and Shut -Off; HVAC systems shall be equipped with
automatic controls capable of accomplishing a reduction of energy use
through control setback or equipment shutdown during periods of non -use
or alternate use of the spaces served by the system. The automatic controls
shall have a minimum seven-day clock and be capable of being set for
seven different day types per week,
Exceptions:
1. Systems serving areas which require continuous operation at the
same temperature setpoint.
2. Equipment with full load demands of 2 kW (6,826 Btu/h) or less
may controlled by readily accessible manual off -
hour controls.
1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets
serving conditioned spaces shall be equipped with dampers which close
automatically when the system is off or upon power failure. Stair shaft and
elevator shaft smoke relief openings shall be equipped with normally open
dampers. These dampers shall remain closed in normal operation until
activated by tho fire alarm system or other approved smoke detection
system.
Exceptions:
1. Systems serving areas which require continuous operation.
2. Combustion air intakes.
1412.6 Heat Pump Controls: Unitary air cooled heat pumps shall include
microprocessor controls that minimize supplemental heat usage during
start-up, set -up, and defrost conditions. These controls shall anticipate
need for heat and use compression heating as the first stage of heat.
Controls shall indicate when supplemental heating is being used through
visual means (e.g., LED indicators).
1412.6 Combustion Heating Equipment Controls: Combustion heating
equipment with a capacity over 225,000 Btu/h shall have modulating or
staged combustion control.
Exceptions:
1, Boilers.
2. Radiant Heaters.
1412.7 Balancing: Each air supply outlet or air or water terminal device
shall have a means for balancing, including but not limited to, dampers,
temperature and pressure test connections and balancing valves.
1413 Air Economizers
1413.1 Operation: Air economizers shall be of automatically modulating
outside and return air dampers to provide 100 percent of the design supply
air as outside air to reduce or eliminate the need for mechanical cooling.
1413.2 Control: Air economizers shall be controlled by a control system
capable of determining If outside air can meet part or all of the building's
cooling loads.
June, 1995
1413.3 Integrated Operation: Building Heating Energy: Air
economizers shall be capable of providing partial cooling even when
additional mechanical cooling is required to meet the remainder of the
cooling load. Controls shall not preclude the economizer operation when
mechanical cooling Is required simultaneously.
Exception: Economizers on individual, direct expansion, cooling
systems with capacities not greater than 75,000 Btu/h may
include controls that limit simultaneous operation of the
economizer and mechanical cooling for the purpose of preventing
Ice formation on cooling coils.
1414 Ducting Systems
1414.1 Seating: Duct work which is designed to operate at pressures
above 1/2 inch water column static pressure shall be sealed in accordance
with Standard RS -18. Extent of sealing required is as follows:
1. Static pressure: 1/2 inch to 2 Inches; seal transverse Joints.
2. Static pressure: 2 inches to 3 inches; seal all transverse joints
and longitudinal seams.
3. Static pressure: above 3 inches; seal all transverse joints,
longitudinal seams and duct wall penetrations.
1414.2 Insulation: Ducts and plenums that are constructed as part of the
building envelope shall meet the requirements of Chapter 13. Other ducts
and plenums shall be thermally insulated per Table 14 -5.
Exceptions:
1. Within the HVAC equipment.
2. Exhaust air ducts not subject to condensation.
3. Exposed ductwork within a space that serves that space only.
1416 Piping Systems
1416.1 Insulation: Piping shall be thermally insulated in accordance with
Table 14-6.
Exception: Piping installed within unitary HVAC equipment.
Water pipes outside the conditioned space shall be insulated in
accordance with Washington State Plumbing Code (WAC 51 -26)
1420 SIMPLE SYSTEMS (PACKAGED UNITARY EQUIPMENT)
1421 System Type: To qualify as a simple system, systems shall be one of
the following:
a. Air cooled, constant volume packaged equipment, which provide
heating, cooling or both, and require only external
connection to duct work and energy services.
b. Air cooled, constant volume split systems, which provide heating,
cooling or both, with cooling capacity of 54,000 Btu /h
or less.
c. Heating only systems which have a capacity of less than 5,000
cfm or which have a minimum outside air supply of
less than 70 percent of the total air circulation.
All other systems shall comply with Sections 1430 through 1438.
1422 Controls: In addition to the control requirements In Section 1412,
where separate heating and cooling equipment serve the same temperature
zone, thermostats shall be Interlocked to prevent simultaneous heating and
cooling.
1423 Economizers: Economizers meeting the requirements of Section
1413 shall be installed on packaged roof top fan - cooling units having a
supply capacity of greater than 1,900 dm or a total cooling capacity greater
than 54,000 Btu/h.
The total capacity of all units without economizers shall not exceed
240,000 Btu/h per building.
1424 Separate Air Distribution Systems: Zones with special process
temperature requirements and/or humidity requirements shall be served by
separate air distribution systems from those serving zones requiring only
comfort conditions.
Prepared by Evergreen Refrigeration Inc. 11/5/99
RECEIVED
CITY OF TC)1(0
NOV - 8 1999
PERMIT CENTER
ACTIVITY NUMBER: M99 - 0221 DATE: 11 - -
PROJECT NAME: N. C. MACHINERY
XX Original Plan Submittal
Response to Incomplete Letter #
Response to Correction Letter # — Revision # __After Permit Is Issued
DEPARTMENTS:
Buil•i Division
Q 11 - "t' J
lib Works
WRROUTE,DOC
5/99
PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
TB .(,
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Approved n Approved with Conditions
6-lo
Fire Prevention
A1,0 11
Structural n Permit Coordinator
Planning Division
DUE DATE: 11-9-99
Complete a Incomplete n Not Applicable
Comments:
TUES /THURS ROUTI G:
Please Route Structural Review Required El No further Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS: (ten days) DUE DATE 12 -7 -99
Approved n Approved with Conditions' Not Approved (attach comments) n
REVIEWER'S INITIALS: DATE:
CORRECTION DETERMINATION: DUE DATE
n
91
C
Not Approved (attach comments) n
REVIEWER'S INITIALS: DATE:
C.
City of Tukwila
Fire Department
Fire Department Review
Control #M99 -0221
(510)
Re: N.C. Machinery - 17025 West Valley Highway
Dear Sir:
November 10, 1999
Thomas P. Keefe, Fire Chief
The attached set of mechanical plans have been reviewed by
The Fire Prevention Bureau and are acceptable with the
following concerns:
1. H.V.A.C. units rated at greater than 2,000 cfm require
auto - shutdown devices. These devices shall be separately
zoned in the alarm panel and local U.L. central station
supervision is required. (City Ordinance #1742)
H.V.A.C. systems supplying air in excess of 2,000
cubic feet per minute to enclosed spaces within
buildin ?s shall be equipped with an automatic shutoff.
Automatic shutoff shall be accomplished by
interrupting the power source of the air - moving
equipment upon detection of smoke in the main
supply -air duct served by such equipment. Smoke
detectors shall be labeled by an approved agency for
air -duct installation and shall be installed in
accordance with the manufacturer's installation
instructions. (UMC 608)
Dedicated fire alarm system circuit breaker(s) shall
be equipped with a mechanical lockout device. (NFPA
72 (1- 5.2.8.2))
Duct smoke detectors shall be capable of being reset
from the alarm panel. (City Ordinance #1742)
All new fire alarm systems or modifications to
existing systems shall have the written approval of
The Tukwila Fire Prevention Bureau. No work shall
commence until a fire department permit has been
John W. Rants, Mayor
hlvailm,artorc ("tatlnn. AAA Andnuor P Vac'. • T» l udla Wachinotnn 01111211 a Dhnn.,. 10111 C7CAA/IA . Env,. /0/IAI C7CAA4n
Yours truly,
City of Tukwila
Fire Department
Page number
obtained. (City Ordinance #1742) (UFC 1001.3)
Contact The Tukwila Fire Prevention Bureau to witness
all required inspections and tests. (UFC 10.503)
(City Ordinance #1742)
Any overlooked hazardous condition and /or violation of the
adopted Fire or.Building Codes does not imply approval of
such condition or violation.
The Tukwila Fire Prevention Bureau
cc: TFD file
ncd
51�
John W. Rants, Mayor
Thomas P. Keefe, Fire Chief
• Ds..u...._ AAA A T. 111...11410.;14...... not oo fl1. ...'MRiU eve_ AAA eoa.I flAI C7[_ 420
Nov 19 99 10:29a Evergreen Refrigeration 206 763 2389
DEPARTMENT OF LABOR AND INDUSTRIES
! F625-052-000 (NW)
•
NATURESAVER MEMO 01616
To
CoiDept, . I
P hone
Fax
I id
pages
I 10 r
Date
From pit
Mme
Fax I
I “."'"""- WachAndOlsinnyCeEMMni.
REGISTERED AS PROVIDED BY LAW AS
CONST CONT SPECIALTY
REGIST. # EXP. DATE
CCAAAB EVERGI*201D7 07/31/2000
EFFECTIVE DATE . 03/27/1980
EVERGREEN REFRIGERATION INC
727 S KENYON
SEATTLE WA 98108
hi,ich And l'hylay Cernilehle
••.
•
pt
fA -7-cmAc-*--p;iL
v■f,
•
• • •
P • 1
SYMBOL LEGEND
SYMBOL
ABBY.
DESCRIPTION
H
AIRFLOW
DUCT SECTION SLPPLY
MIN. OSA,
COOLING
DUCT SECTION - REfLRN /EXHAUST
ff
WEIGHT',
RECTANfiJLAR DUCT
- 2 p ,
— ---
TOTAL
ROUND DUCT
.\/\
INPUT
FLDCBLE DUCT
AFUE
VD
VOLUME DAMPER
L.C.A.
MAX FUSE
ZD
ZONE DAMPER
°�—
TOTAL
MD
MOTORIZED DAMPER
--.
FD
FRE(DAMPEt
PSC.
.._ „vIJ II ,'. ._� ..
' , ^ 6 r, 1 16 1, 15fibrigav romeaSREW _".J .
— -
Ipl _
- i
BTUH
i does not tut :.CfR9 the Vloiason
Calsi , TIOiV DAMPER .
'�d COdy p1 Ord1nB11liE. RBGaPt
I@
50
SM10IE-DET£t, albt0Y111/d000
Q
T
LBS
TFERNOSGXTC
Q
5
Dots 7
,,,,,
- -_R_ - R__ -
R
!)it, 0.�.3.y1 `.'
F'CY-,6tvnQP
_ -_6 - -G- --
G
NIATLRAL 6. LIxES
Ea
:
CELNG DV 61.,PLY)
208 -230
30
GELJIVG DFFUSER O:ETLRWEXHAI
50 -
875 I SS
EXHAUST, FAN (CO2' MOUNTED)
C ol
1042
1,,E FAN
A T
PROPELLER FAN
CH- :.'' al., L
,1„..
SDEWALL DFFUSEZ
/ /.
Y .ECT;;Ic; AL
.....
DUCT FTTNG
UCVi' Nlra
80..1 12' 2 ..
.,
DATLM
-...
L 1T TAG r_.....
.._..__
0 •
-' .
DUCT RISER
GAS PACKAGE EQUIPMENT SCHEDULE
MARK
MANF.
MODEL
TONS.
AIRFLOW
'SP
MIN. OSA,
COOLING
HEATING
ELECTRICAL
WEIGHT',
CFM
INS
CFM
TOTAL
SEER
EEEU
INPUT
OUTPUT
AFUE
VOLTS
PHASE
L.C.A.
MAX FUSE
UNBT ECON
OSA DPR
',CURB
TOTAL
BTUH
BTUH
BTUH
( %)
(V)
(A)
LBS _LBS
LBS
LBS
LBS
PGP I
LENNOX
60516- 090 -200
7.5
3000
0.5'
600
92,800
- --
9.0
200,000
160,000'
80
208 -230
30
42
50 -
875 I SS
--
107
1042
EXHAUST FAN SCHEDULE
MARK
MANF. /MODEL
OEM
S.P. VOLTS
HP /Amps
PHASE
NOTES
EF 12
: GROAN 5
40
€/8' I5
as A
i
Located on ceiling
EF 3
GROAN 314M6
145
I /B' &5
Oa A
i
Located on ceiling
DIMENSIONS INCHES (MM)
Basic Unit With EMDH16M (Horizontal) Economizer Damper Section & RMF16 Roof Mounting Frame
CORNER WEIGHTS
AA
lbs. kg
235 107
294 1,33
B8
lbs.
273
329
kg
124
149
Motlel
Number
GCS16 -090
GCS16 -120
SITE PLAN
SCALE NONE
TOP VIEW
OPENI.NGT EMIDHI6M
(254) r Famahetl00OGEDtfi
_ G erlly Exhaust O mparel
CENTER OF GRAVITY
Model
Number
GCS16 -090
GCS16 -120
CONDENSER COIL FAN
(dual Fane On 13oj
eLs
inch
24 -1/2
34
EE
622
864
Inch
43-1/2
FF
CONDENSER SECTION END VIEW
041
1105
=
SU PACT 4 • 4
1 IIIJJJ J C LLLIII J
FI TEP 26- 3/A__� � ❑
< ♦ I- -- - I6B4, �; 111111 l
I
i\I
�OUTADOOfl DAD AIR \II. Ill.
1 1 1 1 I D
IR \ EWES �!' \
; \ \' FI(TERS I
H H F I. I \( II'I it I I.!i
)
L - AIA_ I IIII : \� I Illy'
1 -1/2 P L fl I 1;1 D
(36j IN DAIAPEAS
OPTIONAL GEDI6 DAMPER
GRAVITY E %HAUSTDAMPERS MOTOA
(Fivlo inaielieuj
Model No.
GCS16-090 II 88 -1/2
GCS16 -120 98
2489
48
60
mm In
1219 39
TM
2248
1524 48
991
1168
13 -1/4
19 -1/4
MM
337
489
19 -7/16
25 -1 /4
mm n.
494 32 -1/2 816
641 39 - 1/8 1 994
1 -5/8
MT
In.
28 -3/4
34 -3/4
41
730
883
DIMENSIONS - INCHES OHM)
Basic Unit
CORNER WEIGHTS
AA
lbs. kg
236 107
276 125
BB
lbs.
283
311
kg
128
141
Modal
Number
GCS16 -090
GCS. 120
INDUCEDDRAFT oLOWEo OPTIONAL
LUENEETNT eOTTOMPOWEfl
FAA. ENniY KR
rl
fifllifRlP
F m.O
1111111111111.
111111111 11lr OF G ' v1rv��
E %CNANGEfl)I EVAPOP TOO I r`
III11111111I,..� FK 66s E. I
�i Ul)llt1U' ®ism
TOP VIEW
A
CC
lbs. kg
193 88
268 122
OD
lbs. kg
162
245
JUAN EN1RN AI
OPENUIG
93
jj (B3B) -}
1- 1/2(38) T 1- 12
BACK VIEW
WITH HORIZONTAL SUPPLY 8 RETURN AIR OPENING
69
111
CC
CONDENSER COIL FAN
CENTER OF GRAVITY
Motlel
Number
GCS16 -090
GCS16-120
Inch
28 -1/2
37
EE
-1/1 31/1
TT
724
940
Men
40
43-1/2
TOP VIEW BASE SECTION
FRONT VIEW
i6Efl COIL
1
COMPRESSORS (2)
CONDENSER SECTION END VIEW
FF
1016
1105
Model No.
GCS16 -090
GC516.120
A
In.
88 -1/2 2248 48 1219 39 991 16 -1/2 419 24 -5/8
625
in.
MT
19 - 7/16 494 32 - 1/2 816
98 2/89 60 1524 46 1168 24 610 31 - 5/8 803 25 641 39 994
Mode/ No.
GCS16 -090
GCS16 -120
In. mm in. mm In. mm In. mm In. mm 'In. mm In. mm
1 -5/8 41 5 -5/8 143
II 2 I 51 4 -7/16 j 113
25
31 -118
635,
791
54 -1/2
57 -12
1384
1461
64 -7/8
68
1648
1727
22 -1/8
28 -1/2
562
724
9 -3/4
14
248
356
GENERAL NOTES
DUCTWORK
ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2' TO EACH
DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 470 EACH DIMENSION IF
DUCTWORK 15 ON THE EXTERIOR OF BUILDING.
THE FIRST NUMBER ON ALL DUCT DIMENSIONS 15 THE WIDTH AND THE SECOND
NUMBER 15 THE HEIGHT.
MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING
LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT RATNG LESS THAN 50, PER
UMC 1997, SEC.601.4.
SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN
I/O INCHES AND 2 INCHES. DUCTWORK WHICH 15 DESIGNED TO OPERATE AT
PRESSURES ABOVE I/Z INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED
IN ACCORDANCE WITH STANDARD R5 -15.
L5 ALL DUCT GAUGES PER TABLE 6 - A 4 TABLE 6 -B OF 1987 UMC.
I.b ALL DUCT SUPPORTS PER TABLE 6 -E OF 1887 UMC.
1.7 ATTACH DIFFUSERS AND GRILLES TO T 3AR GRID PER GODE5.
LB BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS.
DUCT INSULATION
2.1 INSULATE OR LINE DUCTWORK PER WA. STATE ENERGY AND MECHANICAL CODES.
GENERAL CONTRACTOR
3.1 GENERAL CONTRACTOR TO PROVIDE AND CUT OPENINGS FOR ALL ROOFTOP,
CEILING, FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING
AND FIRE PROOF LINING PER U.M.G.
3.2 GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATION AND DIMENSIONS
WITH ERI BEFORE FRAMING OPENINGS.
3.3 GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING
A5 REQUIRED FOR MECHANICAL WORK.
3.4 GENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS
REQUIRED FOR MECHANICAL WORK.
35 GENERAL CONTACTOR TO PROVIDE ADEQUATE ENGINEERING AS REQUIRED FOR
MEGHANIGAL WORK.
3, GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL
EQUIPMENT.
3.7 GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY ERI, PROVIDE
ALL GANT STRIPS AND CURB INSULATION, AND SEAL AGAINST LEAKS.
3.B GENERAL CONTRACTOR TO PROVIDE ALL CUTTING AND PATCHING OF T -BAR CEILING
AS REQUIRED FOR HVAC INSTALLATION.
3.9 GENERAL CONTRACTOR TO PROTECT ALL OPENINGS THROUGH FLOORS PROVIDED FOR
DUCTWORK INSTALLATION IN ACCORDANCE WITH TABLE 6A OF UNIFORM BUILDING
CODE (1997 EDITION). WHERE REQUIRED BY SECTION 711 OF UDC 11997).
ELECTRICAL
4.1' ERI TO INSTALL ALL LOW VOLTAGE CONTROL WIRING, CONDUIT WILL BE PROVIDED
BY ELECTRICAL CONTRACTOR.
4.2 ELECTRICAL CONTRACTOR TO PROVIDE ALL. ELECTRICAL CONNECTIONS,
DISCONNECTS, AND ZTARTERS FOR MECHANICAL EQUIPMENT,
43' ELECTRICAL., CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS. AND LOCATIONS
WITH ERI MECHANICAL. PLAN AND WITH FIELD' CONDITIONS.
4.4 ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM' EXHAUST FANS WITH LIGHT
SWITCH.
4.5' ERI TO PROVIDE 7 -DAY NIGHT SETBACK PROGRAMMABLE TYPE T -STAT WITH
CAPABILITY OF 5T DEADBAND.
4.6 ERI TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER.
PLUMBING
5.1 PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL GAS PIPING FOR
MEGHANIGAL EQUIPMENT PER CODE.
5.2 PLUMBING CONTRACTOR OFFSET VENTS 10 FEET MINIMUM FROM ALL HVAC FRESH
AIR INTAKES OR 3' ABOVE HIGHEST POINT OF INTAKE.
5.3 CONDENSATE DRAINS AND DRAIN LINES BY ERI., DRAIN TO ROOF WITHIN IV OF UNITS.
ENERGY CODE COMPLIANCE
Si AT A MINIMUM, 'EACH FLOOR I TO BE CONSIDERED A SEPERATE ZONE. VERIFY
THERMOSTATIC CONTROL FO E ACH ZONE A5 INDICATED ON PLANS.
6.2 OUTSIDE AIR INTAKES, EXHAUST OUTLETS, AND RELIEF OUTLETS SERVING
CONDITIONED SPACES SHALL BE EQUIPS WITH DAMPERS WHICH CLOSE
AUTOMATICALLY WHEN THE SYSTEM 15 OFF OR UPON POWER FAILURE,
PER WSEG SEC. 1412.4.1.
AIR ECONOMISE WHERE .REQUIRED. BY CODE ARE INDICATED BY THE EQUIPMENT
SCHEDULE AT DO% CAPABILITY, CONTROL AND OPERATION OF THE ECONOMISER
SHALL GOMPLI' WITH WSEG. SEC. 1423.
MECHANICAL COP_ COMPLIANCE
7J WHERE REQUIRED PROVIDE AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS
IN EACH SYSTEM DELIVERING HEATING OR COOLING A IN EXCESS OF 2000 CFM.
DETECTORS SHALL BE LOCATED IN THE MAIN SUPPLY AIR PER UMC M97 SEG. 608.
AI AM
INV MP
W W W W
I- I- I- I-
B < < <
O 0
DRAWING DATE:
Machm9
M ■RECEIVE
CI OF TI I -
JILA
0y 1999
PERMIT CENTER 3
3
z
EVERGI201D7
0
a
z
0
a
m
EVERGREEN REFRIGERATION, INC.
727 SOUTH KENYON
z
0
D
m
m
0
z
HVAC PLAN
NC MACHINERY
17035 WEST VALLEY HWY
TLJKWILA, WASHINGTON 98188
SEATTLE, WASHINGTON 98108
(208) 788 - 1744
FAX (206) 783 - 2389
PROGRESS PRINTS - NOT FOR CONSTRUCTION DATE' a -o&-va
❑ APPROVED FINAL DRAWINGS DATE'
• CONSTRUCTION DRAWINGS DATE:
❑ AS BUILT DRAWINGS DATE'
EVERGI201D7
NC MACHINERY
ELEVATIONS
17035 WEST VALLEY HWY
TUKWILA, WASHINGTON 98188
PROGRESS PRINTS - NOT FOR CONSTRUCTION DATE: 10-06 -99
APPROVED FINAL DRAWINGS DATE'
❑ CONSTRUCTION DRAWINGS DATE:
❑ AS BUILT DRAWINGS DATE:
EVERGREEN REFRIGERATION INC
727 SOUTH KENYON SEATTLE, WASHINGTON 98108
z
0
(208) 789 1744 FAX (206) 783 - 2389