Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M96-0033 - BOEING #2-41
E I& 4G2-401 City of Tukwila L Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M96 -0033 Type: B- MECHAN Category: NRES MECHANICAL PERMIT Address: 8123 EAST MARGINAL WY S Location: Parcel #: 000160 -0020 Contractor License No: BOEINC*294ML TENANT BOEING #2 -41 8123 EAST MARGINAL WY S, SEATTLE, WA 98124 OWNER BOEING PO BOX 3707 - M/S 1F-09, SEATTLE WA 98124 CONTRACTOR BOEING COMPANY P.O. BOX 3707, M/S `IF -09,' SEATTLE ,.WA 98124 CONTACT LARRY ALLEIti. Phone: 206 544 -1644 P.O. BOX 3707, M/S 19-35, SEATTLE, WA 98124 *************** k. **** k***********************' k* ** * * * *k * * * * * * * * **k * * **kk *k ** Permit Description REVISEDUCT WORK ETC. TO SUPPORT .NEW CORRIDOR. UMC Edition: 1994 ******* k*.** k*****' kk*********.********** ********** *•kkk *li * ** * * * *: *•k* *' * *k *k *kk* aa Permit - Center Authorized Signature Date I hereby'certify:that I, have read andeXamined this permit and know the same to ".be' and correct., All 'provisions of law and ordinances; governing this work will be :"complied with,' whether specified herein or not The granting' of thi,s permit does not presume to give authority .to violate or cance.,l'!,the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain thi.sbuilding permit. . Signature: (� Print Name: 9. P., Valuation: Total Permit Fee:,. Title:___ ..� (206) 431 -3670 Status: ISSUED Issued: 03 /22/1996 Expires: 09/18/1996 Date 4.000.00 58.13 This permit shall become.null and. void if/the work .is ~not commenced within 180 days from the dateof :.i.ssu.ance, or if the work"'is suspended or abandoned for a period of' 180; days from. the .last inspection. L '1!6 • . • 445t CITY•OF TUKWILA • AddresSL 8123 EAST MARGINAL WY S • Permit No: M96-0033 SUite: Tenant:130EING #2741 Status: ISSUED Type: B Applied: 02/27/1996 ParCel .#: a00160-0020 Issued: 03/22/1996 *-v),**.k***4**44 Permit Conditions: 1. No Changes will be made to the plans unless, approved by the Architect or Engineer anci,.., Bui Wing DiViSi011. 2. All permits, inspec approved . Plans s h a l l be avai 1 ab e at the i or to € he - '-start any con - truction. ThecOdtsments; ire t� be ma ,itit avai 1 - able anti i 1 f inal. iripectIon .approval is granted. 3 All con t r pAt1bn to be th appv'ove plans an9,:,::;te4u i rements Of el) e Un 1 form Bu 11 d 1 951 ( 94 Ed i t 1 on) , ',",aS ameptied;. Un 1 Me Cliirilta 1 Cod e''''(,1994 Edi t. on) , and Wa 'State , Energy A Code .(1994 Edit opf). 4. Vail dAty7 of' Pet'mi t '1)e 1 uinc, a perMi't or approval of plansiv cat :rims and computitIons sha 1 I" not • s trued to; we a perrnit for or anappova1 of any v 1 at ifin: of ,any of7the p'rov si.i4ns of 1the'''b ui ldi ng code of any other. .osqifilance of Jur tsd i ctIon!.. No permit p'Os.ufifnq o. g.authorlty to v iViate-O0 cancel' the prov1lon o1 thl s ' cct40t' ;haI1 be 5. M OF ACT URER, 1:j45 ALPVI:ION ;INtTR)i,CTIONS -Rq,OUIRED ON SITE • ,• F REvvgw, 14.ri 6. E h..a 1 pet mi t :Ii 11 e ob )i,ned''throilgh the WashIngyjpn ,CON s i.1)n a'nid; a n(1 all ele rica .0"4b eo n s 016 t4 y iii(t\ a gent:y-424a -6630) . e., DEPARTMENT' DATE IN ,.: . DATE APPR VED RE QUIREMENTS /COMMENTS BUILDING - initial review n_a� 3 0 RO TED) CONSULTANT: Date Sent - Date Approved - , O' �;. 0 O FIRE BY: ( init. FIRE PROTECTION: Sprinklers U Detectors CAN /A FIRE DEPT. LETTER DATED: INSPECTOR: INIT: BY: (init.) O PLANNING ZONING: BAR/LAND USE CONDITIONS? O Yes (J No SCREENING REQUIRED? Q Yes Q No INIT: REFERENCE FILE NOS.: O OTHER INIT: BUILDING - final review „.- .. UMC EDITION (year): OY INIT: ( 4 BUILDING OFFICIAL c v l ' -Oct () INIT:i 1 AMOUNT OWING: t 4 a _ i , •.._ CONTACTED 1 0 y � 1 {QG (� �, I.o,t o ir�l!C DATE NOTIFIED -� & �—_ :Y: Init. , O' �;. 0 2nd NOTIFICATION BY: ( init. 3RD NOTIFICATION BY: (init.) PROJECT NAME 15Dain - 4 - 1 - -Q - I-1 1 SITE ADDRESS SUITE NO. PLAN CHECK NUMBER 0033 x REVIEW COMPLETED CITY OF TUKVV.�. . a $i • Department of Community Development — Permit Center 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Mechanical Permit Application Tracking DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ", date and initial. 01/07/93 SITE ADDRESS 3 � 1)7 r UITE # � — J/ I VALUE OF CONSTRUCTION - $ yea0/ p � PROJE NAME/TENANT ASSESSOR ACCOUNT # TYPE OF WORK: O New /Addi • tE,Modifications Vi Repair 0 Other: PHONE VK / 6 1/ 4l DESCRIBE WORK TO BE DONE: R - .� g... � e0,4„4„,,, .-Q -w o (.v a�-� W k 0 2 'GYPE °: :: .::.,::. RATINGiSIZE > NUMBER:OF UNITS <? >:.. :. ;. : �j- PHONE zip, ,/ 5 ., , - CONTRACTOR Ae 0-�� ADDRESS BUILDING USE (office, warehouse, etc.) ZIP NATURE OF BUSINESS: WILL THERE BE A CHANGE IN USE? (53f 0 Yes IF YES, EXPLAIN: 9 , WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? No 0 Yes IF YES, EXPLAIN: PROPERTY OWNER PHONE VK / 6 1/ 4l ADDRESS ?0 i&,_,74, 7 0 2 ' ZS /9-- 3 S` �j- PHONE zip, ,/ 5 ., , - CONTRACTOR Ae 0-�� ADDRESS ZIP WA. ST. CONTRACTOR'S LICENSE # ' `, � (, 9 , h2 EXP. DATE 3 _�, 0 , E- 7 -- CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 PLAN CHECK NUMBER APPLICATION MUST BE FILLED OUT COMPLETELY MECHANL.4AL PERMIT APPLICATION Mechanical Fee Worksheet must also be filled out and attached to this application. FEES (for staff use only) DESCRIPTION BASIC PERMIT FEE:`: :AMOUNT::. $15:00: UNIT(S)' FEE '.': PLAN CHECK FEE OTHER::: TOTAL :::; RCPT;. #. : HEREBY :. CERTIFY :THAT :I HAVEO . READ :AND EXAMINED:THISAPPL.ICATI.ON AND CORRECT, AND i :'AM :AUTH TO A PPLY FOR THIS PERMIT. ;` BUILDING OWNER SIGNATURE OR PRINT NAME AUTHORIZED / 4 , AND KNOW THE SAME TORE TR DATE c" 7- 94. PHONE «9- AGENT CONTACT PERSON ADDRESS '© 3719 7 CITY2IP�� • PHONE , , y4 /y_ APPLICATION SUBMITTAL In order t nsure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Application and plans must be complete in order to be accepted for plan review. BUILDING OWNER /AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. VALUATION OF CONSTRUCTION The valuation is for the work covered by this permit and must be filled in by the applicant. This figure is used for budget reporting purposes only and not to calculate your fees. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Mechanical Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development at 431 -3670. DATE APPLICATION ACCEPTED 0 DATE APPLICATION EXPIRES S- a - 9 O, ,,,94 SUBMITTAL CHECKL MECHANICAL Completed mechanical permit application (one for each structure or tenant) n Two (2) sets of mechanical plans, which include: • Floor plan • System layout • Elevations (for roof mounted equipment) • Heat Loss Calculations Note: . Hood and duct systems require a building permit for the duct shaft. Structural calculations stamped by a Washington State licensed engineer may be required if structural work is to be done (2 sets) Water heaters and vents are included in the UMC — please include any water heaters or vents being installed or replaced. . 7aq` S'.t,8s"�"'`�Ii•�„ •e► * ** * * *A•4* ** * * **4*A *** * *k**** I:TY QF TUKwILA, WA P*4** kA * * * *A * *k** *A *k:1lc * "k •A* tRANSMIT; Number:. 96003848 Am Payment Method: CHECK Nova Permit No: M96 -0033 Parcel Na 000160••C'020 Site Address: 13123 EAST M 'type: I3 --MI 13R1INt4I. WY Tot Fees: .This Payment' 58. :13 Total ALL Pmts: 58.13 Balance: .00 :1 ksl kki4AAk * * ;4 *' k, 4. A**• k- 4 *•Aki. ***4 * .k *4:4•k4A * *:4** *•A k * *•k:4a. *k•k4* ** *A ;Jr •4 *A* Account Code Description • 000/345.83'0 PLAN CHI.CI( •• NUNRES 000/322.100 MECHANICAL - NONRES 0-12: \TZ� LommQr6 * k4 k* A**** *A* *4 * ?A *AA. *k *+4 * *•b: *A * *•k. � TRANSMIT *4 * *4 �• 4* * * * *4 *A * *•kA *A•4A4A4Ak ODb.gel clot, .03 Pri Clllnt: Lion: 'BOEING TRUST ACC ir1i CHAU MECHANICAL PERMIT S al 58.'13 Amount 11.63 46.50 • a1 U6 PPa ou r* 451),13 GENERA 11.63 GENERA 46.50 VOID GENERA -58.13 CASH 0.00 3967A000 15 :47 Project: 1 1 / Type of inspection Address: Date called: Special instructions: Date wanted: ,/ f s ... 1,�' y �, (raj p.���. Requester: Phone No.: pproved per applicable codes. COMMENTS: I 1 [Receit No.:. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 % PERMIT NO. (206) 431 -3670 Corrections required prior to approval. $42.00 REINSPECTIO FEE REQUIRED. Prior to, inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedulereinspection, Date: aS Project e,Nt.? I. 9 , 4i Type of in specjjA o _ i m e re s: rzoitioz_ W4 S Date called: ` y 6 f pecial instructions: 2 ON FL, oo?-• brR ►D -16 E" P / A s Date wanted: j "{ Z A o pm. Reques _ P Tr eR90 nl o�n�ye o.. 2 . 2.902, INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicableVodes: COMMENTS: Inspector I (206) 431 -3670 Corrections required prior to approval. Date: I( •• w• Jr • $42.00 REINSPEC 7 0N FEE EQUIRED. Prior to I spection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. L ReceiPt No.: Date: March 8, 1996 Larry Allen Boeing Commercial Airplane P.O Box 3707 M/S 19 -35 Seattle, WA 98124 RE: Mechanical Application Plan check number M96 -0033 Dear Mr. Allen, C City of Tukwila Department of Community Development John W. Rants, Mayor Steve Lancaster, Director Plan review of the subject project has 'determined the need for further information and detail regarding required Fire Damper installation for the 1 -Hour rated corridor construction. Please review the submitted design and provide applicable revisions. To confirm you have received these comments, contact this office and /or submit revisions within ten working days. Feel free to call me if there are any questions 8:30am to 5 :00pm at 431 -3670. Sincerely, V, Ia., Ken Nelsen Plans Examiner 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 4313670. Fax (206) 41313665 O1'04 '96 16:15 Department of Labor & Industries Contractor Registration Section PO Box 44450 Olympia WA 98504.4450 ID:BCSIS CONTRACTOR FAX: ( ii itogred ounii;"*""A /0).9 kogisorat on nuacr p.4,.evi i .. 4 Regiontion op;;;; Contractor: Your Cenificnte of Registration will be NOD I'm the Olympia office and Certificate of Registration. should be received within 2 to 3 weeks, Please keep Ilus record until you receive your Citr F625-036.000 fCSilltrallon verifIcnLion 2 95 0) REGISTRATION VERIFICATION • TEMPO1111 :4RY itAX (360) 9()2•5228 (360) 902 5226 • 01poiti I letillwiarters ....... PAGE 1 'Th ft, you ..... ............••• •.••••• •+,..•■•••••••••••••■•••■■••••••............................,•••••••••••■•••••••••••■-,.........................,••••,... ..•••••••••••...........”••••••• .•••••••••••.....................4.,••••• ............:•.••••••••••••■•• . . . 1 .. . . . , . . . . . . . . • . . . . IN C M PLANT 2 PROJECT AREA l understand that the Plan Check approvals are subject to errors and omissions and approval or t plans does not authorize ;he violation of any Receipt - ef con-1 Rece ladopted code cr ordinance- ackno�r,�•.edgad. ' c {approved plans ractor scoP1` By HIS DRAWING HAS BEEN RELEVELED TO THE 1988 LEVEL LIST 2 -51 1 2 -64 2 -63 VICINITY MAP P s 2 -55 0 ;- I - 12 - 68 \61 -1100 0, a 2 -5 II I PERMIT RED FOR: ® MECHANICAL .LECTRICA` PLUMBWi C3 GAS PIPING CITY of TD ISIo BUILDING w GATE B -18 SITE ACCESS SYM REVISION BY APPROVED DATE SYM m REVISION PROJECT TITLE: IMPROVE EXITING PROJECT SUMMARY 1. PROJECT ADDRESS: 7755 EAST MARGINAL WAY SOUTH SEATTLE, WA, 98109 BUILDING: 2 -41 2. DESCRIPTION OF WORK : CONSTRUCT NEW FIRE RATED CORRIDOR AND OTHER MODIFICATIONS FOR IMPROVED EXITING FROM THE 2- 41,2 -44 AND 2 -49 BUILDINGS. 3. OWNER: BOEING COMMERCIAL AIRPLANE GROUP WEST REGION FACILITIES P.O. BOX 3707, M/S 19 -38 SEATTLE, WA. 98124 -2207 65) 1010M• ATTN: LARRY ALLEN SHEET NO ARCH I TECTURAL 2 -41 -A0 2- 41 -1A3 2- 41 -2A3 2- 41 -1A25 2- 41 -2A20 2- 41 -2A21 2- 41 -2A24 2- 41 -2A25 2- 41 -A200 2- 41- 2A294R 2- 41 -2A294 2- 41- 2A295R 2- 41 -2A295 2- 41 -A352 2- 41 -A508 2- 44 -1A10 2- 44 -1All 2- 44 -A350 2- 49 -1A10 2- 49 -1A11 2- 49 -1Al2 2- 49 -A350 BY APPROVED DATE FACILITIES DEPARTMENT BUIL PROJECT AREA = 1400 SF COVER SHEET NEW COMPOSITE FLOOR PLAN REV. A COMPOSITE FLOOR PLAN REV. A FLOOR PLAN REV. A FLOOR PLAN REV. B FLOOR PLAN REV. H FLOOR PLAN REV. E FLOOR PLAN REV. H WALL SECTIONS NEW REFLECTED CEILING PLAN REMOVAL REV. R REFLECTED CEILING PLAN REV. E REFLECTED CEILING PLAN REMOVAL REV. R REFLECTED CEILING PLAN REV. G DOOR SCHEDULE NEW SECTIONS & DETAILS NEW FLOOR PLAN REV. A FLOOR PLAN REV. A DOOR SCHEDULE NEW FLOOR PLAN REV. C FLOOR PLAN REV. E FLOOR PLAN REV. D DOOR SCHEDULE NEW ❑ AUBURN, WA. 98002 ❑ EVERETT, WA. 98201 ❑ KENT, WA. 98031 ❑ PORTLAND, OR. 97220 ❑ RENTON, WA. 98055 if SEATTLE, WA. 98124 TITLE REVISION TUKWILA ZONING: MIC /H CONSTRUCTION TYPE V,N OCCUPANCY B -, OFFICE SEISMIC ZONE 3 FULLY SPRINKLERED BUILDING CODE AND BUILDING DATA TOTAL BLDG. AREA = (2.31, 2.40, 2.41, 2.44) = 1,490,300 S.F. DRAWING INDEX MECHANICAL ACCEPTABILITY DRAWN BY THIS DESIGN AND /OR Smith SPECIFICATION IS APPROVED CH CK D ELECTRICAL 2- 41 -1E25 LIGHTING REV. K 2- 41 -2E21 LIGHTING REV. I 2- 41 -2E24 LIGHTING REV. N 2- 41 -2E25 LIGHTING REV, H 2- 41 -2E74 208Y/120 VOLT POWER REV. C 2- 41 -2E75 208Y/120 VOLT POWER REV. D 2- 41 -2E24R LIGHTING REV. N 2- 41- 2E25R LIGHTING ., i \IC- REV. H APPROVED BY DEPT. DATE EAf1NELHLD BY �D APPROVED APPROVED SHEET NO1 MOD NgI LEGAL DESCRIPTION APN: 000160 -0020 A TRACT OF LAND BETWEEN THE DUWAMISH WATERWAY AS ESTABLISHED BY COMMERCIAL WATERWAY DISTRICT #1 OF KING COUNTY, WASHINGTON AND EAST • MARGINAL WAY IN SECTION 33, TOWNSHIP 24 NORTH, RANGE 4 EAST, W.M., AND IN THE JOHN BUCKLEY DONATION CLAIM NO. 42; SAID TRACT ALSO BEING THE SOUTHERLY PORTION OF A LARGER TRACT COMMONLY CALLED THE BOEING COMPANY'S PLANT NUMBER TWO SITE, DESCRIBED AS FOLLOWS: BEGINNING AT THE SECTION CORNER COMMON TO SECTIONS 28, 29, 32, AND 33; THENCE SOUTH 88'08'07" EAST ALONG THE NORTH LINE OF SAID SECTION 33, A DISTANCE OF 982.00 FEET TO AN INTERSECTION WITH THE SOUTHWESTERLY MARGIN OF EAST MARGINAL WAY; THENCE SOUTH 47'51'53" EAST ALONG SOUTHWESTERLY MARGIN 684.62 FEET TO THE TRUE POINT OF BEGINNING OF THE TRACT HEREIN DESCRIBED; THENCE SOUTH 42'25'24" WEST 1215.02 FEET MORE OR LESS TO A POINT ON THE NORTHEASTERLY MARGIN OF SAID DUWAMISH WATERWAY, SAID POINT BEING ON A CURVE FROM WHENCE THE CENTER BEARS SOUTH 42'16'23" WEST 1969.12 FEET; THENCE SOUTH- EASTERLY ALONG SAID CURVE, A DISTANCE OF 397.99 FEET TO THE POINT OF INTERSECTION WITH A LINE LYING 825.00 FEET SOUTH, AS MEASURED AT RIGHT ANGLES, OF THE NORTH LINE OF THE JOHN BUCKLEY DONATION LAND CLAIM NO. 42; THENCE SOUTH 89'09'36" EAST ALONG SAID LINE, PARALLEL WITH THE NORTH LINE OF SAID DONATION LAND CLAIM NO. 42, A DISTANCE OF 1387.45 FEET TO THE WESTERLY MARGIN OF EAST MARGINAL WAY; THENCE NORTH 22'32'15" WEST 160.30 FEET, FOLLOWING SAID WESTERLY MARGIN TO THE POINT OF CURVATURE OF A CURVE HAVING A RADIUS 2828.00 FEET; THENCE NORTHWESTERLY ALONG SAID CURVE, A DISTANCE OF 1250.10 FEET TO THE POINT OF TANGENCY OF SAID CURVE; THENCE NORTH 47'51'53" WEST 76.82 FEET TO THE TRUE POINT OF BEGININNG; THIS TRACT CONTAINING AN AREA OF 1,162,188.74 SQUARE FEET, MORE OR LESS. 2- 41 -2M24R HVAC REV. R 2- 41 -2M25R HVAC REV, R 2.41- 2M124R PLUMBING REV. R 2- 41- 2M125R PLUMBING REV. R 2- 41 -2M21 HVAC REV. F 2- 41 -2M24 HVAC REV. F 2- 41 -2M25 HVAC REV. J 2- 41 -2M271 FIRE PROTECTION REV. B 2- 41 -2M274 FIRE PROTECTION REV. C 2- 41 -2M275 FIRE PROTECTION REV. E DATE SUBTITLE O ?. ?2.96 IITLE ARCH MASTER TITLE REVISION COVER SHEET BUILDING 2 -41 n4 `` ' y' ° RECEIVED CITY OF TUKWILA 7E 9 t PLT 2 PERMIT CENTER LAST REVISION ISYM SHEET AO JOB NO. 750554 - 000 DWG. NO. 2 - 41 - AO DATE OF EQUIPMENT LIST REF N0. DESCRIPTION ® CONTEMPO A/C UNIT SEE 2.41 -2M74 FOR DETAILS Lm 7 BSC MODEL CW-2, 2 TON (24000 BTU), CEILING MOUNTED, CHILLED WATER SPOT COOLER WITH 5KW ELECTRIC REHEAT, PANEL HUMIDIFIER WITH ELECTRIC WATER HEATER, CONDENSATE PUMP AND WALL MOUNTED CONTROLS, 230VAC * ' ELECTRIC REHEAT COILS (2) INDEECO OPEN COIL, 30x30 SLIP -IN 40 KW, 480VAC, 3 PH, 1 STAGE WITH CONTROL OPTION 'K' PROPORTIONAL _CONTROLER WITH THERMOSTAT 20X18 240 CFM 48X24 RELIEF LOBBY 1 10 "cl 400 CFM 12X9 24X12 24" STATIC ILLE RELIEF- 30X28 I �c M 18X15 DATE 7/25/89 4/3/89 12/13/89 O. 18X9 INSTALL HEATING COIL J 730344 -0 E FAN CONTROL ON CMCS A/C UNIT - AS BUILT /HEATING COILS IMPROVE EXITING J# 750554 -00 JR730473 -00 � REO BOLL I G 12/8/95 BOX3 REDRAWN FROM 102 -041 - 4196 -M11 DATED8/23/8 PRVD INCREASED AIR FLOW D9010253 AS -BUILT REVISED OFFICE WALLS RELOCATE 4 LABS J #103088 - AS -BUILT 500 CFM 24X24 RELIEF (TYP OF 4) 20X18 DN 30X26 4 1 11 1 ■ t' I' s=�_ s�a ,,, m _ ADD 48 - X RELIEF ' Worn IC). 18X9 TOE moor 16. 18X9 iiil , , 4il��, PI - ',� 112X3 I El 9/27/90 15 ° c( CUT NEW INSTALL BRANCH TURNING CONNECT RELOCAT 48X24 RELIEF 00 CFM CS 12"V 8X24 RELIEF 48X24 48X24 :TOILET 41 WOM REST ROOM D 48 "X 24 RELIEF GRILL 27X14 20X18 DN 18X15 30X20 ON TO VAULT IN TUNNEL 48X24 47X30 25X18 25X30 VAV BOX 38X18 48X24 RELIEF 20 KW ELEC. COIL,36X16 SLIP IN 20X18 Dfb 48X24 I RELIEF o CGRATH 10/19/9 27X14 48X24 RELIEF SLIP IN 4 VAV BOX 33X18 300 CFM (2 TYP) 1 50 CFM 12 "¢' 26X30 AFATIEZAIW FACILITIES DEPARTMENT 25X30 30X26 48X24 RELIEF 20X18 48X24 RELIEF 25X18 EXISTING UNIT H 8 V 500 CFM ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DRAWN BY SLOAN CHECKED R.GLADNEY CHECKED 3/13/89 7/25/89 7/25/89 MECHANICAL MASTER BUILDING 2 -41.2 COL G- I/16 -22 PLANT 2 009012 2.41 -2M24R A B C 11 - 1II111��► 15X15 18X15 X15 X15 10'� 2u �I 'A. 420 D8 -5 .'.� 12 "�+ CFM 24 "X 24" DIFFUSER, 6 "g NECK REPLACE DUCT. ADD VOLUME DAMPER. ADJUST FLOW TO 130 CFM. DR -3 5 - 910 15 "9( 15" 6, 20X18 DN 15'ff 15'16, 15 - r - M15 "f DR -3 18X15 12 " rnqbco33 SUBTITLE ^'�^^ PLEX DUCT 0 FORCED AIR SUPPLY 4 -WAY DIFFUSER z RETURN GRILLE LEGEND: 7 DUCT HEATER SPOT COOLER GENERAL NOTES: x 1. DIFFUSERS)/15"o/THROAT SHALL BE ADJUSTED TO 900 CFM UNLESS OTHERWISE NOTED 2. DIFFUSERS W /10 "0 /THROAT SHALL BE ADJUSTED TO 350 CFM UNLESS OTHERWISE NOTED 3. SEE DWG #102 -041 -4196 M-16 FOR AHU -30 ELEVATIONS DATE 12/8/95 COMP NO. RECEIVED CITY OF TUKWILA FEB 2 _j.,,.. DUCTWORK CONSTRUCTION NOTES - REMOVE EXISTING EXHAUST INLET, DAMPER AND DUCT WORK. REMOVE DAMPER CONTROL AIR BACK TO SOURCE REFERENCE DRAWINGS 2.41 -2M519 (VAV BOX DETAILS) 2.41 -2A294 (REFLECTED CEILING) M10 M14 KEY PLAN SCALE: NONE 730473 -00 lAST REVISION SHEEP 2M24R M11 M15 M12 M16 ?TT? T? TT - &is Q i 111 M25 111 it SYMBOL R HVAC WAS 102 -041- 4196 -M11 EQUIPMENT LIST REF N0. DESCRIPTION HUMIDIFIER, DR1- STEAM, MODEL VPC -4-4 -4 INSTALL HUMIDIFIER 'L TUBE THRU SIDE OF DUCT DOWNSTREAM OF BAG FILTER. CONNECT TO HUMIDIFIER W/1 -1/2' STEAM HOSE W /HUMIDIFIER TO ONE SIDE OF DUCT. , 1 ; , , CONTEMPO A / C U N I T SEE 2.41 -2M75 FOR DETAILS ® MOUNTED, BSC MODEL CW-2, 2 TON (24000BTU), CEILING CHILLED WATER SPOT COOLER WITH 5KW ELECTRIC REHEAT, PANEL HUMIDIFIER WITH ELECTRIC WATER HEATER, CONDENSATE PUMP AND WALL MOUNTER CONTROLS, 230 VOLT 000 SEE 2.41 - 1M75 SYM A B C 47'X 30 STATIC = RELIEF ZONE 3 I� Ij UMW! ► IMF i t �� Efil -- - 12'X 16 _ — - ' 26 / 'X 30' i iv ' \! \ B ° 300 CFM ilk �`� 'y _ = o x _ (5 TYP) 6111111 - °' .- 72 x 20'X 18' DN T al ' I IIIIIII M NIIW MIEEME[= '1 \1M�Im IEMIUM.. Ala ib=tiNII�� ' ' • 11I :r Z RE 24' jet wii j x o RELIEF 11 gig co NE II \' II N41111: III 26'X 30" 30'025 -38'X 18' VAV BOX 3000 CFM 48 "X 24' RELIEF DUCT HEATER 36 ° X 16 48'X 24' t M25 M502 30 ° X 2", UP TO A C - 18 30 "X 20' 26 "X 30" 30 ° X 20' 2 ° X 10' 14 KW HUMIDIFIER 20'X 18 DN 30 ° X 25' LADDER (EXIST) A /C -36 A /C -38 CFM 510 (180) i 25 X 20' M522 (4 TYP. 4 "J(TYP) x 14 = X 48 , ; I � m UP TO AC /18 30'X 20' 1111111111 30'X 26' ERN 18'):9 12'� CFM 400 (100) REVISION 19' VAV 600 REDRAWN FROM ENGEBRETSON 9/23/83 A/C FOR 200K ROOM #750732 -00 MOVE DIFFUSERS J #173217 -00 RELOCATE DIFFUSERS, JOB# 183007 RELOCATE LEARNING CENTER J #193049 - 20 IS DRAWING HAS BEEN RELEVELED TO THE 1988 LEVEL LIST (A)(M)- BY APPROVED WJB WRG DATE 11- 10 -86G 2/1/88 H RLS WJE JP WRG 3/21/88 COLBY RDS 7 -21 -89 SYM F R REVISION RELOCATE 4 LABS J #103088 VENTILATION 2.41.2 J #400018 ADD A/C MCAD J #710097 -02 COMP' RM. A LAB J #720330 -00 IMPROVE EXITING J #750554 - 00 M7 PLAN VIEW SEE DETAIL OVEN EXHAUST FAN. IGL,MODEL FC6 -1075, 500 CFM @ 1/8' S.P., 1/4 HP,120V. SCALE: 1/8 "= 1' -0" BY SPG APPROVED WON WDB WDB WOB SPG DATE 9/27/90 1/10/91 8/6/91 1/11/93 12/8/95 FACILITIES DEPARTMENT ❑ AUBURN, WA. 98002 ❑ EVERETT, WA. 98201 ❑ KENT, WA. 98031 ❑ PORTLAND, OR. 97220 ❑ RENTON, WA. 98055 ■ SEATTLE, WA. 98124 NEW 18' X 0-3 9' 47'X 40 UP TO A C -34 114'X 47' PLENUM 40'X 40' rnw33 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. )ATE DRAWN BY SLOAN DATE 01- 29--88 02 -01 -88 02 -01-88 SUBTITLE TLE MECHANICAL MASTER 5. 111111111111 RECEIVED ciTV of Tuicwiva FEB , ( PERMIT CENTER DUCTWORK BUILDING 2.41 LEGEND -- SPOT COOLER FORCED AIR SUPPLY FORCED AIR RETURN FORCED AIR OUTLET HUMIDISTAT THERMOSTAT GENERAL NOTES 1. HVAC DIFFUSERS IN ALL BRANCH DUCTS SHALL BE ADJUSTED TO 900 CFM UNLESS OTHERWISE NOTED. 2. ALL DIFFUSERS TO BE LOCATED BY DWG. #102 -41- 1375 -A26, REFLECTED CEILING PLAN. 3. HVAC BRANCH DUCTS TO BE SUPPORTED ON TOP OF TRUSS MEMBERS AND SECURED. 4. ALL NEW DUCTWORK TO BE INSTALLED IN ACCORDANCE WITH SMACNA LOW VELOCITY DUCT STANDARDS. FORCED AIR DUCTWORK TO BE SUPPORTED BENEATH TRUSS MEMBERS AND SECURED. 6. HVAC SUPPLY AIR DUCTWORK TO BE INSULATED WITH 1 -1/2" THK.THERMAL INSULATION. 7. FORCED AIR SUPPLY DUCTWORK TO BE INSULATED WITH 2 "THK.THERMAL INSULATION. 8. ALL RETURN AIR DUCTWORK TO BE LINED WITH 1" ACOUSTIC INSULATION. 9. ADJUST ALL FORCED OUTLETS AT 600 CFM. 10. FIELD FABRICATE AND INSTALL VOLUME DAMPERS IN ALL. BRANCH DUCTS. 11. SEE DWG. #102 -041- 4196 -M16 FOR A /C #34 ELEVATION. 12. ALL OVEN VENTS SHALL BE 6" DIA AND ADJUSTED TO 100 CFM. CAR -MON BELT DRIVE FAN, MODEL CMB -10F 1 HP, 3172 RPM, 1168 CFM, 10 PJHEEL DIA. 230/460, 208V, 31, 1.50" SP. CONSTRUCTION NOTES REMOVE EXISTING EXHAUST INLET, DAMPER AND DUCT WORK. REMOVE DAMPER CONTROL AIR BACK TO SOURCE. REFERENCE DRAWING 2.41 -2M320 CONTROLS M102- 041 -4045 CONTROLS M102 -041 -4047 CONTROLS 102 - 041 -4198 102 - 041 - 1375 -A26 (REFLECTED CEILING PLAN) M10 M11 M13 0 M14 M15 M12 MI6 M2O M17 KEY PLAN SCALE: NONE COL. G -1 11 -6 PLT 2 R 12/8/95 LAST REVISION ISYM DATE SHEET 2M25R JOB NO. DWG. NO. 009012 2.41 -2M25R WAS 102- 041 - 4196 -M12 OF 845 EQUIPMENT LIST REF N0. DESCRIPTION Ark CONTEMPO MODEL CEMC -20 —D 2429MBH AT 72'FDB, 150 %R.H., 2 EACH, 3 H.P., 460VAC, 3 PHASE, 50 GPM @ 45'EWT, 8.1PSI DROP i SPOT COOLER SEE 2.41 -2M24 FOR SPECS IMF PRESSURE REDUCING VALVE, WATTS U5B INITIAL PRESSURE: UP TO 300 LBS ADJUSTABLE REDUCED PRESSURE RANGE: 25 TO 75 LBS. MAX TEMP.: 160' F SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE 0 �//J� / g �0 FACILITIES DEPARTMENT ❑ EVERETT, ❑ KENT, ❑ PORTLAND, ❑ RENTON, MI SEATTLE, WA. WA. WA. OR. WA. WA. 9802 98 98031 97220 98055 98124 ACCEPTABILITY SPECIFICATION IS APPROVED DRAWN BY R.L.SLOAN DAqT 4/SJ 12/1/90 SUBTITLE PLUMBING LAST REVISION ISYM DATE A RELOCATE 4 LABS J �` WDB 9/27/90 CHE R K ��ADNEY SHEET 2_ V B ADD A/C MCAD J#710097 AP BY DEPT. )ATE ENGINEERED BY TITLE MECHANICAL MASTER BLDG. 2-41.2 COL. G I/16 22 PLT 2 C REPLACE WATER PIPING J #730252 01 MCGRATH YOB RFG t/13Js4 NECKED CHECKED d08 NO 009012 R IMPROVE EXITING J #750554 -00 SPG _ SPG 12/8/95 I G 9/27/90 DWG. NO. 2.41- 2M124R APPROVED FIRST FLOOR M74 M522 EXISTING H & V UNI S DRAWING HAS BEEN RELEVELED TO THE 1988 LEVEL LIST (A) EDGE OF WOMEN'S TOILET ROOM Ic0 TO WOMEN'S RESTROOM PLAN VIEW SCALE: y8= 1' -0 10 z� z PUN CUD TO CW 4 0 rnq b&33 3 RECEIVED CITY OF TUKWILA FEB 2 Ilililllllll GENERAL NOTES 1. HANGER SPACING FOR COPPER PIPE: 1 1/2" & SMALLER: 6' INTERVALS 2" & LARGER: 10' INTERVALS PRESSURE REDUCING VALVE. SET TO 60 PSI. REMOVAL NOTES REMOVE EXISTING AIR DROP BACK TO VALVE AND PLUG VALVE. LEGEND SPOT COOLER KEY PLAN SCALE: NONE 1110 D 12/5/95 EQUIPMENT LIST REF No. DESCRIPTION 0 HUMIDIFIER, DR1- STEAM, MODEL VPC -4-4 -4 INSTALL HUMIDIFIER "L" TUBE THRU SIDE OF DUCT DOWNSTREAM OF BAG FILTER. CONNECT TO HUMIDIFIER W/1 -1/2" STEAM HOSE W /HUMIDIFIER TO ONE SIDE OF DUCT. U1 CONTEMPO MODEL CEMC -20 -D 2429MBH AT 72'FDB, 1505R.H. 10,000 CFM, 2 EACH, 3 HP, 460VAC 3 PHASE, 50 GPM @ 45'EWT, 8.1 PSI DROP a ® SPOT COOLER SEE 2.41 -2M25 FOR SPECS Aul HUMIDIFIER: CARNES MODEL #HBGD53U040 40LB /HR MAX.OUTPUT, 460V, 3 PHASE WITH HXPBC -036 DISTRIBUTOR PIPE AND MODEL HXHA -H DUCT HUMIDISTAT s HUMIDIFIER: CARNES MODEL #HBHD53U120 120LB /HR MAX.OUTPUT, 460V, 3 PHASE WITH HXPBC -036 DISTRIBUTOR PIPE ce p` SEE DWG. 2.41 -1M75 TH BELOW FLOOR SLOPE 1 /2 "CW 6' WASTE ON 1 /2'CW DN UP 6'WASTE DN 1/2' SLOPE EXIST PIPING CLW Q __ 1/2 . SLOPE 3/4" CLW FROM AHU 2 -41 -36 3/4" AIR (IN FLOOR) ,. TIE INTO EXIST. DRAIN @ COL.H /14 7-1/2" CW 1/2" ' SLOPE CLW 13/4» Y a 1/2" 1" AIR DOWN THROUGH FLOOR SLOPE 1 1/2" 3/4" CLW 3/4 CL>V FROM AHU FROM AHu 2 -41 -37 2- 41 -38; SLOPE RUN C D TO FIRST FLOOR N er ,, TOO IDIFI R 2.41+37 1/2" - e A /C -38 1/2" T HUMIDIFIER AHU 2 -41 -38 2 "VTR DETAIL U � U D I °ST F SEE DETAIL M12 M52 EWC 0 1/2" COND' as a-ai a-r z- +�y l 1/2" HW C MATCH LINE SEE SH.M -117 2 i" N' SA _L� • I n.... 1 -1/2 DN NEW 1 WHW UNDER FLOOR 6"ROOF DR NEW DWG 2.40- 1M1i9) �H� - -- -- T EX I ST' G 2" SAN & VTR ON I EXIST: VON al 1%4CW DN EXIST'G SINK NEW WHW DN THRU FLOOR ROC PLAN V I EVE! SCALE: 1/8 "= 1' -0" TO 1/2 HUMIDIFIER IN AHU 2 -41 -18 1/2" TO HUMIDIFIE AHU 2-41- 2" IN CEILING OF FIRST FLOOR HW SAN 1" UNDER FLOOR (SEE DWG 1 1/2" TRAP CO 1 1/2" VTR 2.40- 1M119) 1" AIR DN C S M522 CLEAR WATER DRAIN FROM COOLING COIL; AHU 2 -41 -34 " COND SEE DETAIL 1/2" VTR 1/4" TRAP ILING FLOOR MATCH LINE SEE SH.M -129 M12 M522 DN THROUGH FLOOR rfl GENERAL NOTES 1. PIPING TO BE PER BOEING STANDARDS. 2. FIELD VERIFY DIMENSIONS BEFORE FABRICATING. 3. AID PIPING TO BE SCH. 40 BLK. W /MI. FITTINGS. 4. THERE ARE NUMEROUS AIR DROPS ABOVE THE CEILING. 5. HANGER SPACING FOR COPPER PIPE: 1 1/2" & SMALLER: 6' INTERVALS 2" & LARGER: 10' INTERVALS REMOVE EXISTING AIR DROPS BACK TO VALVE OR BRANCH AS REQUIRED AND PLUG OR CAP. MI12 M113 M117 QJ 4 _IP4_ M120 M124 M128 KEY PLAN SCALE: NONE RECEIVED CITY OF TUKWILA F E 2 :' 096 PERMIT CENTER A -NW- DA- -CW- -CLW- -SAN- REMOVAL NOTES of Q M 0 M114 M115 M116 COMPRESSED AIR (100 PSIG NOMINAL) HOT WATER DRY AIR COLD WATER CLEAR WATER DRAIN SANITARY WASTE STD. DUPLEX AIR DROP SPOT COOLER SUM A B C D E REVISION RELOCATE LEARNING CENTER J #193049 -20 INSTALL LAGUN MILL J# 681244-01 RELOCATE 4 LABS J #103088 ADD A/C MCAD J #710097 -02 ADD AIR DROPS J #720330 -00 IS DRAWING HAS BEEN RELEVELED TO THE 1988 LEVEL LIST (A)(M) /DAD :DI ' FACILITIES DEPARTMENT ❑ AUBURN, WA. 98002 ❑ EVERETT, WA. 98201 ❑ KENT, WA. 98031 ❑ PORTLAND, OR. 97220 ❑ RENTON, WA. 98055 SEATTLE, WA. 98124 EY CO BY EGG �5 cs's A� REPLACE WATER PIPING REVISION J #730252 - 01 DATE -21 -89 5 -01 -89 9/27/90 8 - 6 - 91 1/13/93 APPROVED RDS RDS WEB WDB WDB SYM F R IMPROVE EXITING J# 750554 -00 BY MCGRATH SPG APPROVED WDB RFG SPG DATE 1/13/94 12/8/95 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. TATS DRAWN BY 8. A.MEHTA R.GLADNEY 3- 18 -88 urommm NY W. BUCKLEN 3 -18-88 CHECKED J.PETRAM 3 -21-88 APPROVED W.R.GEHRING APPROVED DATE 3- 21 -88 SUBTITLE TLE MECHANICAL MASTER PLUMBING BUILDING 2.41 COL. G- 1/11 -16 LAST REVISION ISYM SHEET 21M125R JOB NO. 009012 DWG. NO. PLT 2 2.41 2M125R DATE OF 1061 G 2/8/95 SAM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE o �� /SDA10 /� O FACILITIES DEPARTMENT ❑ AUBURN, ❑ EVERETT, ❑ KENT, 1:1 PORTLAND, El RENTON, D3I SEATTLE, WA. WA. WA. OR. WA. WA. 98002 98201 98031 97220 98055 98124 AC DESIG N /Y THIS C TION I A APPR SPECIFICATION S APPROVED DRAWN BY D R SMITH DATE 7 11 6 SUBTITLE DU CTWORK LAST REVISION SAM DATE A REDRAWN FROM TANABE & RENUMBERED 10 -24 -83 ,R' F IMPROVE EXITING 4750554 SPG SPG 12 8 95 / / R.GLADNEY �1 -29 -88 SHEET 2 V 2 1 OF B RELOCATE THERMOSTAT J/172217 00 y p 5 45' JP WRG ME APPROVED BY DEPT. )ATE ` : ,2 01 88 T ITLE MECHANICAL BLDG. 2 - 41.2 COL. MASTER I --p/11-16 _,E1 2 C MODIFY DUCTS, JT 1 y % ' JP WRG 02 - 01 - 88 JOB N0. 009012 E2 -146 0 REARRANGE B.A. FACILITIES J #780422 - 00 =" RDS WRe�. s�. RM A PPROVED 02 -01 -88 E CONTROLS FOR FANS J #780543 �� .' BC RDS - 13 - 8•' pyG p10, 2,41, TAT IAND 1ON CLOCK WALL Sit. 36 ° X 18 12b0 CFM T -STAi IN SUPPLY M19 201-Mi 700 12' CFM A.D. 12'0 urVysMIMM 700 I I!Ili�\ CFM 1• Dim itI II 14 iNiti• 1.11=1 u�» A.D. 200 CFM 12' ►� ri 12' A.D. 700 CFM 12' A.D. 12" 10 300 A.D. CFM 16X14 12 700 .D A. ERIN P2:41 R.G.48X24 24X10 R.G.48X24 700 CFM A D. R.G.48X24 12'0 700 M19 4201 CFM A D 36X30 4- 15 "8.D.'5 900 CFM EA. 114X47 18X9 I 15X18 255180N PACE MODEL A36AF 24X48 RELIEF 5KW UCT HEATER 6X16 18X15 ZONE 2 CONNECT TO EXIST. "X33" THRU ; ii 30X20 114X25 PLENU6 10 A.D. 400 CFM VARIABLE VOL.BOX VVB -1 48X24 300 CFM 48X38 Mira: 2 0 il I 12" BLANK OFF 17 A.D. 0AEF E 14 ; ,I).71�I��_ 10 A. 4 oa 85 X I UP ` " THRU iF :� 10' 1CAPPED ' O/ 10 0' ` VARIABLE VOL.BOX 700 VVB -2 CFM 700 CFM 12' A.D. 24X24RAG S -300 CFM 10 ° 0 2 -10 S -35 EACH 24X48 RELIEF CD CFM 48024 RELIEF 5- 15 ° A.D.'S 900 CFM EA. 38X18 VAV BOX 3600CFM S-900 CFM EXISTING DIFFUSER S -800 CFM 24X48 RELIEF GENERAL NOTES LOCATE DIFFUSERS AND RELIEF GRILLES AS PER REFLECTED CEILING PLAN 2.41- 1A289. ALL DUCT INSTALLATIONS SHALL BE PER SMACNA AND BOEING STANDARDS. CONSTRUCTION NOTES INSTALL NEW ONE HOUR 36" X 18" FIRE DAMPER IN SUPPLY AIR DUCT AT NEW FIRE WALL. 1 -1/2 HOUR RATED VERTICAL MOUNT, GREENHECK MODEL FD 150 TYPE A OR EQUAL. INSTALL NEW ACCESS DOOR FOR FIRE DAMPER PER NFPA. LABEL FIRE DAMPER CLEARLY PER BOEING STANDARD. NIGHT 7-DAY MOUNT ZONE DUCT B REGISTER I i OFF14 RELIEF M194201 - M2 TYP. A. OFFICE 11 L'ATIONS L ..... nr■■■ nri rum cM1 Tn TUC 11:100 I CUC1 I I CT /A \ /IA 5'0 AIR DIFFUS R"'750CFM W/15" T014 TRRNSITION TYP.4PLGS) THERMOSTAT 0 TURN PUMP ON ABOVE 68 18_X 18" SOU TURN *TURNING V ES AT TOP OF RISER 2M518 2M21 PLAN VIEW SCALE: 1/8 "= 1' -0" HV SYSTEM 02 -041 S05-H 35000 CFM 50 ° X 47" DOWN TO 1ST FLOOR A/C UNIT ON FLOOR - CONTEMPO FLR. MTD. UPFLON, 65.3 MBH TOTAL 56.3 MBH SENSIBLE, AT 75/62.5 P ENT- AIR, 45`F. ENT -CHILLED WATE 3000 CFM, 1/2 ESP, 2 H.P. FAN MO OR, WW/ GIANT #VC -35C cONOENSAT • MATCH LINE SEE 102 -041 - 4196 -M9 60 "X50 DOWN TO 1ST FLR 111111 • L ] -p 4KW HUMIDIFIER 90X26 PLENUM 18000CFM SYSTEM #02- 041S29- HV- 2M -I12 ry) q- 14KW HUMIDIFIER 18X9 15'0 VOLUME DAMPER S MATCH LINE CFM SEE 2.41 -2M21 W33 RECEIVED CITY CF TUKWILA FE 12 / ;' PERMIT CENTER REFERENCE DRAWING 2.41 -2M320 CONTROLS M102- 041 -4045 CONTROLS M102 -041 -4047 CONTROLS 102 -041 -4198 2.41 -2M512 CONTROLS 2.41 -1M17 2.41 -1M21 2.41 -RFM21 2.41 -2M315 CONTROL DIAGRAM 2.41 -2M317 CONTROL DIAGRAM 2.41 -2M518 DETAIL) 617 � 025 P C I KEY PLAN SCALE: NONE 0 0 00000 00 0 ©000 F 12 -8 -95 12X12 DR -3 30X2623 E -AO ADD 48'X 15-14CUT NSTAELW 0 I , d01 LET BRANCH UCT TURNING VANES �`� CONNECT TO REST ROOM RELOCAT D GR I �). 15X15 18X15 1o'f to'f 10'c! i 1u II" siu 40X34 X15 10 20X12 20X15 El -- all YCY L�J COIL 12 "V IN 12X12 240 CFM 48X24 RELIEF LOBBY 10 400 CFM 12X9 24X12 24" STATIC ILLE RELIEF 20X18 DN 20 KW ELEC: COIL,36X16 SLIP IN 20X18 DN 30X28 ! ?‹ 18X15 30X20 ON TO VAULT IN TUNNEL 48X24 18X15 7/25/89 12/13/89 9/27/90 10J 18X9 27X14 ■BEN FAN CONTROL ON CMCS A/C UNIT 4 730473 -00 AS BUILT /HEATING COILS IMPROVE EXITING J# 750554-00 BOLLIG 10/19/9 4/19/94 112X3 ,-112 10 "V 12X12 .7 T 10 t 0 V 2- LI 10"v 27X14 'its 30X26 20X18 26X30 x 30X3 MI , I!! 1:X15 ! 18X15 �M'E 15" f 15 "t 4 R LIEF 20X18 #y Y 500 CFM PRVD INCREASED AIR FLOW 09010253 B AS -BUILT REVISED OFFICE WALLS C RELOCATE 4 LABS J #103088 - AS -BUILT 24X24 RELIEF (TYP OF 4) - REDRAWN FROM 102 - 041 - 4196 - M11 DATE08/23/8 20X18 DN 15 "q 15 - v 00 CFM 48X24 RELIEF 47X30 f� • ' t ■■11rill ?6;��f I / I Alan IMAM, MMA_T I . 4 N a �aiD 48 "X 24" 1 RELIEF GRILL 5EJ CFM 8X24 RELIEF PLAN VIEW SCALE: yg'= 1 ' - 0 " EVI RSION VAV BOX 38X18, 48X24 - RELIEF 48X24 RELIEF 24 "X 24" DIFFUSER, cg NECK REPLACE DUCT. ADD VOLUME DAMPER. ADJUST FLOW TO 130 CFM. ®F ®�� FACILITIES DEPARTMENT 48X24 DR -3 E -A0 48X24 RELIEF 20X18 DM 48X24 RELIEF 12X10 EXISTING UNIT H 8 V 18X15 500 CFM ACCEPTABILITY THIS DESIGN AND /OR SPECIRCAIWN IS APPROVED APPROVED. BY DRAWN BY SLOAN CHECKED R.GLADNEY ENGN CHECKED APPROVED D.S.ZULLIG APPROVED 3/13/89 7/25/89 7/25/89 MECHANICAL MASTER DUCTWORK FIX DUCT 0 FORCED AIR SUPPLY 0 4 -WAY DIFFUSER DI RETURN GRILLE LEGEND: 1 DUCT HEATER MM SPOT COOLER BUILDING 2 -41.2 GENERAL NOTES: X 1. DIFFUSERS /15 "0 /THROAT SHALL BE ADJUSTED TO 900 CFM UNLESS OTHERWISE NOTED 2. DIFFUSERS W/10 "0 /THROAT SHALL BE ADJUSTED TO 350 CFM UNLESS OTHERWISE NOTED 3. SEE DWG #102- 041 -4196 M -16 FOR AHU -30 ELEVATIONS EQUIPMENT LIST REF DESCRIPTION N0. CONTEMPO A/C UNIT SEE 2.41 -2M74 FOR DETAILS BSC MODEL cW-2, 2 TON (24000 BTU), CEILING L� MOUNTED, CHILLED WATER SPOT COOLER WITH © 5KW ELECTRIC REHEAT, PANEL HUMIDIFIER WITH ELECTRIC WATER HEATER, CONDENSATE PUMP AND WALL MOUNTED CONTROLS, 23OVAC ELECTRIC REHEAT COILS (2) INDEECO OPEN COIL, 30x30 SLIP -IN 40 KW, 48OVAC, 3 PH, 1 STAGE WITH CONTROL OPTION 'K' PROPORTIONAL CONTROLER WITH THERMOSTAT CONSTRUCTION NOTES RELOCATE EXISTING DIFFUSER. REFERENCE DRAWINGS 2.41 -2M519 (VAV BOX DETAILS) 2.41 -2A294 (REFLECTED CEILING) PERMIT CENTER VTTIT M10 814 COL G- 1/16 -22 PLANT 2 KEY PLAN SCALE: NONE 730473 -00 LAST REVISION SHEET 2M24 009012 2.41 -2M24 HVAC DATE 12/8/95 OF WAS 102 - 041- 4196 -M11 Am 12X12 DR -3 30X2623 E -AO ADD 48'X 15-14CUT NSTAELW 0 I , d01 LET BRANCH UCT TURNING VANES �`� CONNECT TO REST ROOM RELOCAT D GR I �). 15X15 18X15 1o'f to'f 10'c! i 1u II" siu 40X34 X15 10 20X12 20X15 El -- all YCY L�J COIL 12 "V IN 12X12 240 CFM 48X24 RELIEF LOBBY 10 400 CFM 12X9 24X12 24" STATIC ILLE RELIEF 20X18 DN 20 KW ELEC: COIL,36X16 SLIP IN 20X18 DN 30X28 ! ?‹ 18X15 30X20 ON TO VAULT IN TUNNEL 48X24 18X15 7/25/89 12/13/89 9/27/90 10J 18X9 27X14 ■BEN FAN CONTROL ON CMCS A/C UNIT 4 730473 -00 AS BUILT /HEATING COILS IMPROVE EXITING J# 750554-00 BOLLIG 10/19/9 4/19/94 112X3 ,-112 10 "V 12X12 .7 T 10 t 0 V 2- LI 10"v 27X14 'its 30X26 20X18 26X30 x 30X3 MI , I!! 1:X15 ! 18X15 �M'E 15" f 15 "t 4 R LIEF 20X18 #y Y 500 CFM PRVD INCREASED AIR FLOW 09010253 B AS -BUILT REVISED OFFICE WALLS C RELOCATE 4 LABS J #103088 - AS -BUILT 24X24 RELIEF (TYP OF 4) - REDRAWN FROM 102 - 041 - 4196 - M11 DATE08/23/8 20X18 DN 15 "q 15 - v 00 CFM 48X24 RELIEF 47X30 f� • ' t ■■11rill ?6;��f I / I Alan IMAM, MMA_T I . 4 N a �aiD 48 "X 24" 1 RELIEF GRILL 5EJ CFM 8X24 RELIEF PLAN VIEW SCALE: yg'= 1 ' - 0 " EVI RSION VAV BOX 38X18, 48X24 - RELIEF 48X24 RELIEF 24 "X 24" DIFFUSER, cg NECK REPLACE DUCT. ADD VOLUME DAMPER. ADJUST FLOW TO 130 CFM. ®F ®�� FACILITIES DEPARTMENT 48X24 DR -3 E -A0 48X24 RELIEF 20X18 DM 48X24 RELIEF 12X10 EXISTING UNIT H 8 V 18X15 500 CFM ACCEPTABILITY THIS DESIGN AND /OR SPECIRCAIWN IS APPROVED APPROVED. BY DRAWN BY SLOAN CHECKED R.GLADNEY ENGN CHECKED APPROVED D.S.ZULLIG APPROVED 3/13/89 7/25/89 7/25/89 MECHANICAL MASTER DUCTWORK FIX DUCT 0 FORCED AIR SUPPLY 0 4 -WAY DIFFUSER DI RETURN GRILLE LEGEND: 1 DUCT HEATER MM SPOT COOLER BUILDING 2 -41.2 GENERAL NOTES: X 1. DIFFUSERS /15 "0 /THROAT SHALL BE ADJUSTED TO 900 CFM UNLESS OTHERWISE NOTED 2. DIFFUSERS W/10 "0 /THROAT SHALL BE ADJUSTED TO 350 CFM UNLESS OTHERWISE NOTED 3. SEE DWG #102- 041 -4196 M -16 FOR AHU -30 ELEVATIONS EQUIPMENT LIST REF DESCRIPTION N0. CONTEMPO A/C UNIT SEE 2.41 -2M74 FOR DETAILS BSC MODEL cW-2, 2 TON (24000 BTU), CEILING L� MOUNTED, CHILLED WATER SPOT COOLER WITH © 5KW ELECTRIC REHEAT, PANEL HUMIDIFIER WITH ELECTRIC WATER HEATER, CONDENSATE PUMP AND WALL MOUNTED CONTROLS, 23OVAC ELECTRIC REHEAT COILS (2) INDEECO OPEN COIL, 30x30 SLIP -IN 40 KW, 48OVAC, 3 PH, 1 STAGE WITH CONTROL OPTION 'K' PROPORTIONAL CONTROLER WITH THERMOSTAT CONSTRUCTION NOTES RELOCATE EXISTING DIFFUSER. REFERENCE DRAWINGS 2.41 -2M519 (VAV BOX DETAILS) 2.41 -2A294 (REFLECTED CEILING) PERMIT CENTER VTTIT M10 814 COL G- 1/16 -22 PLANT 2 KEY PLAN SCALE: NONE 730473 -00 LAST REVISION SHEET 2M24 009012 2.41 -2M24 HVAC DATE 12/8/95 OF WAS 102 - 041- 4196 -M11 EQUIPMENT LIST REF N0. DESCRIPTION fb HUMIDIFIER HUMIDIFIER, DR1- STEAM, MODEL VPC -4-4 -4 INSTALL "L" TUBE THRU SIDE OF DUCT DOWNSTREAM OF BAG FILTER. CONNECT TO HUMIDIFIER W/1 -1/2" STEAM HOSE W /HUMIDIFIER TO ONE SIDE OF DUCT. S, V CONTEMPO A/C UNIT SEE 2.41 -2M75 FOR DETAILS V BSC MODEL CW-2, 2 TON (24000BTU), CEILING MOUNTED, CHILLED WATER SPOT COOLER WITH 5KW ELECTRIC REHEAT, PANEL HUMIDIFIER WITH ELECTRIC WATER HEATER, CONDENSATE PUMP AND WALL MOUNTER CONTROLS, 230 VOLT r11)(4) SEE 2.41 - 1M75 SYM A B C E REVISION 19' VA 600 REDRAWN FROM ENGEBRETSON 9/23/83 A/C FOR 200K ROOM #750732 -00 MOVE DIFFUSERS Ja173217 -00 RELOCATE DIFFUSERS, JOB# 183007 RELOCATE LEARNING CENTER J #193049 - 20 S DRAWING HAS BEEN RELEVELED TO THE 1988 LEVEL LIST (A)(M) 38'X 18' VAV BOX 3000 CFM 48"X 24' RELIEF o, x 20"X 18' DN 30 "X 26" 0 "X 20 UP TO A C -18 30 ° X 20" 26 "X 30" . f 30 "X 20" ' 20 "X 18" 2'X 10" 18 "X 9 26 "X 30' Itll1Mbr�■ 041, NW 30"X 25 HUMIDI SEE DE A 25 "X 20' 48 "X 24' M25 M502 4 " }(TYP) 48 "X 24" OVEN EXHAUST FAN, IGL,MDOEL FCB -1075, 500 CFM @ 1/8" S.P., 1/4 HP,120V. 4 "}(TYP) SEE DETAIL M522 (4 TYP.) LADDER (EXIST)�� 30 "X 20 NHUHH V2107 arli1 500CFM M� m (4 TYP))"- 48 "X 24' RELIEF A /C -36 5 -00 =a0a1 A /C -3 A /C -38 18'X9 12'11 CFM 400 (100) M7 PLAN VIEW SCALE: 1/8 "= 1' -0" w w N x �1� 30' 30 � f av IN I iIIIIII // g10 0 FACILITIES DEPARTMENT ❑ AUBURN, WA. 98002 ❑ EVERETT, WA. 98201 ❑ KENT, WA. 98031 ❑ PORTLAND, OR. 97220 ❑ RENTON, WA. 98055 ■ SEATTLE, WA. 98124 NEW 18' X D -3 9° 47 "X 40" UP T A C -34 114 "X 47" PLENUM 40'X 40' APPROVED BY I(1'lq�p -OD33 INN m APPROVED DATE SYM REVISION F RELOCATE 4 LABS J #103088 11- 10 -86G VENTILATION 2.41.2 4400018 WRG 2/1/88 H ADD A/C MCAD J #710097 -02 JP WRG 3/21/88 I COMP' RM. & LAB J #720330 -00 RDS 7 - 21 - 89 J IMPROVE EXITING J #750554 - 00 COLBY DRAWN BY SLOAN R.GLADNEY APPRO W.R RING APPROVED 01 -29-88 02 -01 -88 MIN APPROVED WDB WDB WDB ADD SPG DATE 9/27/90 1/10/91 8/6/91 1/11/93 12/8/95 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DEPT. SATE DATE SUBTITLE 02 -01 -88 TITLE 5. RECEIVED CITY OF TUKWILA FE; 2 PERMIT CENTER LEGEND SPOT COOLER = FORCED AIR SUPPLY FORCED AIR RETURN • FORCED AIR OUTLET © HUMIDISTAT 0 THERMOSTAT GENERAL NOTES INN 1. HVAC DIFFUSERS IN ALL BRANCH DUCTS SHALL BE ADJUSTED TO 900 CFM UNLESS OTHERWISE NOTED. 2. ALL DIFFUSERS TO BE LOCATED BY DWG. #102 -41- 1375 -A26, REFLECTED CEILING PLAN. 3. HVAC BRANCH DUCTS TO BE SUPPORTED ON TOP OF TRUSS MEMBERS AND SECURED. 4. ALL NEW DUCTWORK TO BE INSTALLED IN ACCORDANCE WITH SMACNA LOW VELOCITY DUCT STANDARDS. FORCED AIR DUCTWORK TO BE SUPPORTED BENEATH TRUSS MEMBERS AND SECURED. 6. HVAC SUPPLY AIR DUCTWORK TO BE INSULATED WITH 1 -1/2" THK.THERMAL INSULATION. 7. FORCED AIR SUPPLY DUCTWORK TO BE INSULATED WITH 2 "THK.THERMAL INSULATION. 8. ALL RETURN AIR DUCTWORK TO BE LINED WITH 1" ACOUSTIC INSULATION. 9. ADJUST ALL FORCED OUTLETS AT 600 CFM, 10. FIELD FABRICATE AND INSTALL VOLUME DAMPERS IN ALL BRANCH DUCTS. 11. SEE DWG. #102 -041- 4196 -M16 FOR A /C #34 ELEVATION. 12. ALL OVEN VENTS SHALL BE 6" DIA AND ADJUSTED TO 100 CFM. El> CAR -MON BELT DRIVE FAN, MODEL CMB -10F 1 HP, 3172 RPM, 1168 CFM, 10 ShNHEEL DIA. 230/460, 208V, 31, 1.50" SP. CONSTRUCTION NOTES RELOCATE THERMOSTAT AS SHOWN. ® RELOCATE SUPPLY DIFFUSER. © RELOCATE RETURN GRILL AS SHOWN. DUCTWORK BUILDING 2.41 MECHANICAL MASTER COL. G- 1/11 -6 REFERENCE DRAW 2.41 -2M320 CONTROLS M102- 041 -4045 CONTROLS M102 -041 -4047 CONTROLS 102- 041 -4198 102 - 041 - 1375 -A26 (REFLECTED CEILING PLAN) KEY PLAN SCALE: NONE PLT 2 LAST REVISION J 12895 SH 2 M25 JOB NO. 009012 OWG. NO. 2.41 - 2M25 DAT WAS 102 - 041 - 4196 - M12 OF 845