HomeMy WebLinkAboutPermit M92-0079 - DEMPERE JACKIEm92-0079 dempere jackie hvac 14211 37th avenue south • boweRE, J/V •4 e City of ?hkwil Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: Type: Category: Address: 14211 37 AV S Location: Parcel #: 152304 -9095 Contractor License No: TENANT OWNER CONTACT M92 -0079 B -MECH RES MECHANICAL PERMIT DEMPERE JACKIE 14211 37TH AVENUE SOUTH, TUKWILA, TREMANA INC 33 S; 1,28TH,' .S DEMPERE JACKIE 4033 SOUTH 128TH STREET, TUKWILA, WA 98168 Valuation:= Total Permit Fee:: Status: ISSUED Issued: 11/06/1992 Expires: 05/05/1993 Phone: (206)433 -8539 TUKWILA WA 98168 Phone: 206 433 -8539 WA 98168 ************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * *** k* * * * * * *** * *'k * * *'k ** ** * *** * * *** Permit Description: INSTALL BOILER.. UMC Edition: 1988 (206) 431 -3670 **** r *****************************,** . ********** * * * * * * * * * * * * * ** * * ** * * * * * * * ** Permit - Center Author' -d Signature Signatu Print Name: Date' R.aZ. T i t l e I hereby:dertify that - I have read`an'd examined.this permit and know'the same to: 13 true and correct.. All provisions .of law and ordinances governing.', this work will be compli'e'd with, whether specified' herein or not The granting. of 'thi's permit 'does not ; p,resume to :'give authority to violate or cancel the provisions of any otherstate or local laws regulating construction or.the performance of work: I' am authorized to sign for and obtain th.s'build'ng "perm t. This permit shall: become null and .vo,id.i „f, the work is not commenced within 180 days from the date; of Issuance, ; or i';f ^:the work i s,:w;suspended or abandoned for a period of 180 day`s:from the'last ins'pec'tion. 14211 37 AV S DEMPERE JACKIE B -MECH 152304 -9095 CITY OF TUKWILA Permit No: M92 -0079 Status: ISSUED Applied: 05/08/1992 Issued: 11/06/1992 Address: Tenant: Type: Parcel #: k***• k******** * * ** * *** * **** *•k * *** * * * * *•k * * ** k* *•k *** *•k * *** ** k * * * * * *•k *•k *** * * *** Permit Conditions: 1. No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Plumbing permit shall be obtaine.d..,.tbro,ugh the Seattle -King County Department of Public i ea l t�h . l umbing will be inspected by that agen`cy_;, iliCludin " a1`1 - as;'p`iping (296 -4722) . �a;�,;.r 3. Electrical perm >i`tr shall, be Lob;ta<ine through the* Wash•.ington State Division ,,,of Laborf!,andalIrld.us,tfries and; all, work will b,�e that agency ,7 (248`- 66 4. All ermi�,t ctI inspeon' records`; d 'approve'd,,,plans sh ai ne�d vai lable at, job $psite prior , the start any al�°1� ' on t.r'uct�i'on. These dodUMe are to be mai`n,ta " ,fined a'•� ,., -••; rte until "`final i nspectii on approval is granted,,-f' 5. i ty of" permit:. The.'1.ssuance of permit or 'appro`val rs pec,.i'ficat K 1ons "and computations shall not b "e co�n,7.0 d toa p;ermit••f;pr, or ;fan" "appr:oval of, any violation \' of g of the provisio'vis ;is code %'or of any other s'' nceofF tJie jur:isdiction , No p:erjmviFt-- presuming to , give Wity or viol o kI e ce,l 'tthe,provision of this;, code' be o;f� shallA be. vall id ,e:::. -' ! ' 1 ;r , d � ,, . 3 . 6 Fins it ap'pr.oi.> fr fivaor all ;t'e °nar \ spec tes` i w i / '�thin t he limits of'4Y }, the' .,.outhc Mall ,rp.aiis`l ;on', are \su.b ''ec to the compl•e. -,::� . tio. te;s,11iyg and a °pprova"I #of , " �i,ts\.stoke evacuation system , + x .4"x' �! ( ,, i 1 `�...�;r!' i {a per �� a p t e r t; 5& of t�Ii:e ,.�U ,, ,, ,y� U { ,:. , . �, Y ' I ; E 7. MANU CTUR;, X S 'I INSTROTIO K�'3 REQUIRED ON SITE FOR \ E B.UCILEDING INSPECTORS .REVIEW :n4.� ?.•�- M W 1 4. [ : ,,,, \ d` a� ?•�li'T•:i k PERMIT NO. CONTACTED ��cnn , r DATE READY DATE NOTIFIED ^ BY: QgP PERMIT EXPIRES 2nd NOTIFICATION , -c IQ �� � � � I � � qa ( BY: )� AMOUNT OWIN " � �"' .� 1 3RD N L- ra i l ^ e ee < <� �` " 0'7 ( in i tJ MECHANIC` :. PERMIT APPLICATION TRACKING PLAN CHECK NUMBER 'raga - ocfl• INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. BUILDING - initial review O FIRE O PLANNING O OTHER teStBUILDING - final rAviaw PROJECT NAME SITE ADDRESS REVIEW COMPLETED INIT: INIT: INIT: OUTED) T,� --Pm .re , TCxcKt� FIRE PROTECTION: FIRE DEPT. LETTER DATED: REFERENCE FILE NOS.: UMC EDITION (year): REQ CONSULTANT: Date Sent - S. rinklers SUITE NO. rM E • Date Approved Detectors INSPECTOR: N/A ZONING: IBAR/LAND USE CONDITIONS? ( )Yes ( ) No SCREENING REQUIRED? fYes (l No oF exp'iYo* . bra clod . 011,7/00 .<::<: DESCRIPTION: :::; ; > > >i': , PHONE S 3c) ZIP �% \ € 7 �.cg � z`) PROPERTY OWNER ` =. ADDRESS a <> ><; »; > PH ∎N Li a \ c� ''c \"∎ C �Z. R- CONTRACTOR \Pi\- C \ c— \ —2 - ADDRESS --> t_ 1 `# 1 c ' � EXP. DATE Z IP • WA. ST. CONTRACTOR'S LICENSE .<::<: DESCRIPTION: :::; ; > > >i': i:'> AMO.UNT :' RCPT 4:::: < > << >; :DATE": BASICPERMIT .FEE >:� ><_<: >:. >< 1500 >< $ <> ><; »; > : . : :; : :: ::::: ::» ::: UNITS) :FEE:: ::: :: PLAN 1:CHECK FEE ::: >;.:: OTHER . .TOTAL :'- :; . CITY OF TUKWILA Department of Community Development - Building 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 PLAN CHECK NUMBER CY APPLICATION MUST BE FILLED OUT COMPLETELY SITE ADDRESS PROJECT NAMEJTENANT TYPE OF WORK: 0 New /Addition Modifications 0 Repair DESCRIBE WORK TO BE DONE: BUILDING USE (office, warehouse, etc.) NATURE OF BUSINESS: SUITE # 7 WILL THERE BE A CHANGE IN USE ?,No 0 Yes IF YES, EXPLAIN: WILL THERE B TORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? 'No 0 Yes IF YES, EXPLAIN: APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. A completed "Mechanical Permit Fee Worksheet" must accompany this permit application. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and Dlans must be complete in order to be accepted for elan review. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. VALUATION OF CONSTRUCTION The valuation is for the work covered by this permit and must be filled in by the applicant. This figure is used for budget reporting purposes only and not to calculate your fees. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Mechanical Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development at 431 -3670. DATE APPLICATION ACCEPTED MECHAN.�AL PERMIT APPLICATION Mechanical Fee Worksheet must also be filled out and attached to this application. 0 Other: FEES (for staff use only) VALUE OF CONSTRUCTION - $ .......... ......: ...:...:. N.UMl3ER OF L N S DATE APPLICATION EXPIRES 06/18/90 Project: Type of inspection• Address: Date called: ■IIIIIIII■ Special instructions: Date wanted: ,2/( a:m <' Requester: Phone No.: 2- INSPECTION NO, I INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 [Approved per applicable codes. PERMIT NO. 20.3670 Date: Corrections required prior to approval. Date: "7— _ _ $42.0 s REINSPECTION FEE rEQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I Receipt No.: COMMENTS: el li i A r...,4 h, 9 4.-. .' 4, i / 7 -.Ay ido,..0 e, . Address: i 4.5 I t o jo d frI( 1 7 ( S I ' • . . , _ (.., . s... _ :1:2/ / 4 - . Ivo,— Date Wanted: fri o 1 4es1 i7-7 5 9 , i -- d'A Requester: 6 e S he.F.Ac., sori-- ,6 (... 9 0.--,44-e. ed cyl-- Phone No.: cf .1"I has .1-16, t i fl L: C /511. 4 1-,-,h, ,:9. ,S7 CA i 1 IP fr e.,/,-€ - j fr' e 4. 4 1 .■ 1-••__. • p. 1*' Ze .kid f.f■y &Ada tel .e M/ . c .../ , ‘ t/f /,‘, 4 A ,... fro •.4.- 4/2//,.4'z, . t.I. 1 /, 6,,,,e.... '1_1-w, ;- Ca Pi ci..//ed Ai" / 1 - 1 -14•A■ 1 4 S.. Project: 1-- 1/4) --"Ty771717"-----ectm: — - - - Address: i 4.5 I Date Called: (.., . s... _ Special Instructions: g _. 3D Date Wanted: Requester: Phone No.: Approved per applicable codes. I E NO. Inspector: r INSPECTION RECORD n Retain a copy with permit - - - ` 1 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT (206) 431-3670 0 Corrections required prior to approval. Date 0 $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I .Receipt No.: Dale: T otal s1::Al Payments: 43.7; Bal itno e: GENERA 43.75 TOTAL• 4375 CHECK ': ' 43.75 RANGE 0.00 , 5063A000' 15.50 • k k* k*,** k:• kk* 14* k** k* * ** **** . * ? k ** ** A * * *rk * * * * *?k.h * * * k * * *, * * * * * * . * 'CITY :'OF ` TUKWx :A, , W,A : TRAN$MiT, * * *A * * *; * *A * * ** * * *` * * *sH k* k* * * * **k * * * * :ik,*. ** k ** * ** *, * * ** * *** *o 4` *k. k. *k * **! .. ; TRANSMIT Nu m ber' c, 9 001.254 Amount i i :,43,. 7,5i, . 1i/0/9i/91,'9 S Permit Na :',M92- 00.79, Types '.B -MECH �MECHAN.ICAl. PERMIT P.aircel h4;', ,•5;23.04...9095 Site ;:'A:d dress' ';14211 `37 AV S Payment Method is ' i`lot,at i ari; :DEM` 4 ;3 I ri.i t a ,DL * * * * fir* #.4 *k:7k ** * •d ,..k * * * : * k* * *� * * * * *'**�k * * *k•i #4 *k ** *fi * AA * , Accpunt. Cade Descry i pt i an:** Pa.i:d 000/34830 ` PL'ANY CHECK :M : .R.ES '.:13';',75„'• 000./32 ' ;100 M ' . RES` 3 5.00. T.otal.(TM.is Payment) :: first floor plan electrical gas piping I understand that the Plan subject to errors and Plan Check approvals are ,plans does not a ssions , � nd approval o f adopted. eode uthorixe the violation a copy ' ordinance, Re of any pY of approv d' fans Receipt acknowledged. of con. RECEIVED CITY OF Tl,JKWILA MAY 8 1992 PERMIT CENTER • PEI) 47 1 SECOND FLOOR PLAN . SCALE ' 1 /4 "� 1 BR) -# 2 SAM ai R-N !ks 2 6' -0" M ee oe.erryv\ RECEIVED CITY OF TI IKWILA MAY 8 :1992 PERMIT CENTER Radiant Roll Heating: A Significant Advance Radiant Roll is a patented continu- ous 2 -tube extrusion made of a flexible and durable synthetic elas- tomer that is not affected by most chemicals or temperature ex- tremes. It is stable in concrete, and its long life expectancy ensures years of comfortable and efficient heating. lem ops, it can • the rest . If a a sinuous tire room, rvice. Before the introduction of Radiant Roll, radiant heating systems used metallic tubing or plastic piping. Metallic tube systems can corrode and deteriorate in contact with concrete. Plastic pipes are larger ; an Radiant Roll tubes, requiring a = thicker concrete slab. Plastic piping is also much less flexible than Radiant Roll. It requires more space and is more difficult to install. Unique Counterflow Design Radiant Roll heating uses a two - tube counterflow pattern to create an even and uniform temperature across a radiating floor surface. As warm water is fed into a series of tubes, cooler water in adjoining tubes which has already radiated its heat returns to the boiler to be reheated. Most metal and plastic pipe installa- tions consist of a single, long sinu- ous length of tubing. This means that where the piping enters a room or zone, the floor temperature will be hotter than where it leaves. Another important advantage of Radiant Roll's counterflow pattern is that it employs a number of short individual loops which co the header. Should a p develop in one of the be simply isolated, lea of the system operation problem ever develops i type of installation the rooms, or zone go out o Adaptable To Any Kind Of Flooring Radiant Roll heating systems can be installed in any kind of floor: 1. LIGHTWEIGHT CONCRETE OVER WOOD SUBFLOORS: Radiant Roll is stapled to a wood subfloor and lightweight concrete or gypsum is poured over it. Finish flooring or carpet- ing is then installed. 2. UNDER WOOD FLOORS: Radiant Roll is attached.to the underside of wood subfloors with staples through the web between tubes. A reflective 3. 4. insulation barrier is installed between the floor joists under the Radiant Roll. 3. WOOD OVER WOOD SUB - FLOORS: Radiant Roll is placed between wood sleepers of approximately the same thick- ness as the Radiant Roll tubing. Finish wood flooring is installed to create a "sandwich." 4. WITHIN CONCRETE SLABS: Radiant Roll is embedded in a concrete slab. Finish flooring or carpeting is then installed. 1. Lightweight concrete over wood subfloors. 2. Under wood floors. 3. Wood over wood subfloors, 4. Within concrete slabs. Go for Polytherm. • DAY CARE CENTRES • SCHOOLS • GYMS • CHURCHES • COMMUNITY FACILITIES • SENIOR CITIZENS HOMES • OFFICES • WORKSHOPS • CAR WASHES • SINGLE FAMILY HOMES • TOWN HOUSES • APARTMENTS • POOL DECKS • DRIVEWAYS The radiant floor heating system .. quality makes the d ifferenqe *GG! j\ CIT`( OF TLII JUI4 A 9 \99'1 PERMIT CENTER BUZZ BURGETT v W'u NORTHWEST MECHANICAL 1100 N. W. 54th• Seatt /e, WA 98107 1 (206) 782.7520 teledyne laars Model BTU /Hr. Input A B C D E Water Conn, Gas Conn. I•B•R Net Rtg. Unit Wt (lbs.) .JV-50 50,000 13 1 2 4" 51/" 303/4" 1 "NPT '/z "NPT 36.5 115 JV•75 75,000 13 15" 5" 7 32 1 "NPT '/z "NPT 53.9 120 JV- 100 100,000 16 15" 5" 7 32 1 "NPT 3/4" NPT 72.1 125 JV•125 125,000 16e /e" 20 6" 12" 38" 1 "NPT '/z "NPT 89.5 130 N• 160 160,000 20 20 6" 12" 38" 1'/4 "NPT '/r "NPT 113.9 140 JV•225 225,000 25 28" 7" 18 45 1 "NPT '/x "NPT 160.0 155 From Wall to: Minimum Clearance Left side 4" Right side 6" Rear 2" Models 125/160: 3 "; Model 225: 5" Front Models 50.125: 4" Models 160/225: Unobstructed Flue 6" For Model: Base Assembly Part Number JVS•50 /75, JVT•50/75 4667.01 JVS•100 /125, JVT -100 /125 4667.02 JVS-160, JVT.160 4667.03 JVS-225, JVT-225 4667.04 For Model: Vent Damper Part Number JVS•50 E 984.01 JVS-75/100 E 984.02 JVS-125/160 E 984.03 JVS-225 E 984.04 System Tank Water Content Part Number Less than 20 gallons A-668 • Power Vent For Model: Part Number JVS-50 to JVS-125 105700 Dimensions and Standards 1. Return (Inlet) 2. Supply (Outlet) 3. Draft Hood 4. Aeration Box 5. Relief Valve 6. System Drain 7. Manual Gas Valve* 8, Drip Leg* 9. Automatic Gas Valve 10. Control Box with Pump Relay 11. Temperature /Pressure Gauge 12. Modulating Gas Valve (Models 160 and 225) *Items provided by installer. Accessories Compression Tanks An adequately sized compression tank with suitable air charge and tank drain must be provided. Teledyne Laars offers an air - charged Fill-Trol diaphragm -type tank with automatic makeup water control as an accessory package. Power Vent Kit Power .*nters are now available for use with Type JVS MINI -THERM for direct, through the wall venting. Costly vertical chimneys are eliminated and continuously regulated draft reduces energy cost by providing efficient combustion. Available on Models JVS -50 to JVS -125. •• Accessory Floor Bases MINI -THERM can be installed only on a non - combustible surface unless provided with this accessory base assembly. The base adds only one inch to the boiler heights listed in the table of dimensions. The unit must never be installed on carpeting. Left Side View RECEIVED u� Y ur T1OWILA MAY 8 1992 Top View 12 10 8 — 17'/4"— Right Side View Aut6matic Vent Dampers Designed for use only with the electronic Type JVS MINI-THERM, energy - saving automatic vent damper systems prevent heated air from wastefully going up the open vent when the boiler is not operating. The systems consist of a damper assembly, damper operator and_ wiring harness. The damper operator interlocks electrically with the spark ignition control of the Type JVS. MINI -THERM is equipped with a special vent damper plug -in receptacle for quick, easy installation of the vent damper system. Installation Clearances MINI - THERM fits anywhere, and adap plumbing. Models 50-125 can be installed irh properly ventilated closets. For clearances to hot water pipes and accessories, consult local codes. Minimum wall clearances are as follows: WTELEDYNE LAARS PERMIT CENTER 13230 Saticoy Street, North Hollywood, California 91605 • (818) 76 LAARS / (818) 765.2277 Teledyne Laars Canada: 480 S. Service Road West, Oakville, Ontario, Canada L6K 2H4 • (416) 844.8233 Litho in U.S.A. ©Teledyne Laars GS•503 8705 Doc. 1089D 98168 Mar 02, 1994 JACKIE DEMPERE 4033 SOUTH 128TH STREET TUKWILA, WA RE: DEMPERE JACKIE Dear Permit Holder: Our records indicate that on Apr 06, 1994 one hundred and eighty days will have passed with no inspections having been called for under Tukwila Mechnical Permit Number M92 -0079. Unless you call for an inspection, or obtain a written extension from the Tukwila Building Official prior to that date, your above referenced permit will become null and void on Apr 06, 1994. If your project is complete please call for final inspection. If you are actively working on your project please contact our office. If you have questions or need further information to obtain an extension on your permit please call the Tukwila Building Divison at 431 -3670. Sincerely, h1n4 City of Tukwila Department of Community Development Denise Millard Permit Coordinator Department of Community Development John W Rants, Mayor Rick Beeler, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 431 Apr 02, 1993 JACKIE DEMPERE 4033 SOUTH 128TH STREET TUKWILA, WA 98168 Dear Permit Holder: City of Tukwila John W. Rants, Mayor Department of Community Development Rick Beeler, Director Our records indicate that on May 05, 1993 one hundred and eighty days will have passed with no inspections having been called for under Tukwila Mechnical Permit Number 1492=0079 Unless you call for • an inspection, or obtain a written extension from the Tukwila Building Official prior to that date, your above referenced permit will become null and void on May 05, 1993. If your project is complete please call for final inspection. If you are actively working on your project please contact our office. If you have any questions or need further information to obtain an extension on your permit please call the Tukwila Building Divison at 431 -3670. Sincerely, fit Denise Millard Permit Coordinator Department of Community Development 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206J 431.3670 • Fax (206) 4313665 May 11, 1992. Dear Jackie: City of Tukwila 6200 Southcenter Boulevard • Tukwila, Washington 98188 John W Rants, Mayor Jackie Dempere 4033 S. 128th St. Tukwila, WA 98168 RE: Mechanical permit to install residential boiler system. Plan check number M92 -0079 The proposed tubing circulation systdm has a typical installation in a lite concrete or similar floor product. Given that the existing floor joist system is substandard to current code, the potential additional load of this application may create a more hazardous structural condition. 1. Provide information of the installation of these products and include the additional weight in Pounds per Square Foot. 2. A minimum increase in weight per square foot weight may likely require addition structural corrections to the existing deficient joist system, design by a structural engineer. To confirm you have received these comments contact this office and /or submit revisions within ten working days. Feel free to call me if there are any questions, 8:30 a.m. to 4:30 p.m...at 431 -3670. Sincerely, V ,A.AA. Ken Nelsen Plans Examiner 4002 ._.mbr csait-ex �- c 'ow' r . `NoTALIA Nci pct coc(uzae. Nopt=itKa d441 EX t 191091 f 4045V54 tvw - cPrropexxt 4 4 A CEIIG - ctopeo44 ., Phone: (206) 433.1800 • City Hall Fax (206) 433 -1833