Loading...
HomeMy WebLinkAboutPermit EL07-197 - WESTFIELD SOUTHCENTER MALL - GAME STOPGAMESTOP 2616 SOUTHCENTER MALL ELO7-197 Parcel No.: Address: Suite No: Signature: doc: EL -4/07 Tenant: Name: Address: Owner: Name: Address: Electrical Service provided by: Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 2616 SOUTHCENTER MALL TUKW Value of Electrical: $7,950.00 Type of Fire Protection: Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied GAME STOP 2616 SOUTHCENTER MALL , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA Contact Person: Name: ROB HUMPHREY Address: 833 SE MAIN ST #242 , PORTLAND OR Contractor: Name: SIGN -TECH ELECTRIC LLC Address: 5113 PACIFIC HWY E, SUITE 12 , Contractor License No: SIGNTEL988BG DESCRIPTION OF WORK: CASHWRAP POWER, LIGHTING, WORKSPACE, BATH LIGHTING, STORFRONT SIGN, AIR HANDLING UNIT, AND 2 PANELS itY ELECTRICAL PERMIT Permit Number: Issue Date: Permit Expires On: Phone: Phone: 503 -320 -5030 Phone: 253 - 922 -2146 Expiration Date: 01/07 /2010 Fees Collected: National Electrical Code Edition: ELO7 -197 05/12/2008 11/08/2008 Date: $266.50 2005 r ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the pazfgrmance of work. I am authorized to sign and obtain this electrical permit. Date `e Print Name: 7,///J // / ?C This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. EL07 -197 Printed: 05-12 -2008 Parcel No.: 6364200010 Address: 2616 SOUTHCENTER MALL TUKW Suite No: Tenant: GAME STOP 1: ** *ELECTRICAL * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: EL07 -197 Status: ISSUED Applied Date: 06/08/2007 Issue Date: 05/12/2008 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: doc: Cond -Elec Print Name: Date: c EL07 -197 Printed: 05-12 -2008 Site Address: Tenant Name: Name: Mailing Address: CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** p/ 40' 5 u r tt - Cet•t( t? MICA L 6-cottA es 7. Property Owners Name: 1JV T 0 c D _ e Mailing Address: 1 1 6o l Li) / Litt/ ilC bxVD t// Ol City CONTACT PERSON - Who do we contact when your permit is ready to be _issued My l4-t-e_ts I Is 33 S e MJ (Ai s r -44 ).-y/2 E -Mail Address: 7 @ FACT ? / T . Co", ELECTRICAL CONTRACTOR INFORMATION Company Name: — \ ° Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ 7 ( / 30 Scope of Work (please provide detailed information): C f s 1+-0 l e ?ow 1� �' I C� 14-Tt G` I ¥o i le— SPA C-e: 3o V. I19147 ST01 --( .S «N Will service be altered? ❑ Yes a No Adding more than 50 amps? )'es ❑ No Type of Use: L- ✓ 4 )Ti t✓ E Type of work: ew ❑ Addition ❑ Service Change ❑ Remodel VP Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: Puget Sound Energy ❑ Seattle City Light H:\Applications\Forms- Applications On Lin4-2007 - Electrical Permit Application.doc bh Electrical Permit Project No. or office use only): King Co Assessor's Tax No.: Suite Number: I 0 S Floor: Z New Tenant: Yes ❑..No VS /6 1 6LSLa C4- ' 00 2 State Zip Day Telephone: Svc _ 3 ZO City State Zip Fax Number: ,S`o 2.7 6 - Z 6 3 0 State Zip Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVIC ❑ New single family dwel ' $140.00 (including : : ched garage) ❑ Garages . , a s, spas and outbuildings $75.00 ea ❑ voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered c' nits $75.00 number of added c' its $10.00 ea ❑ Circuits added/altered wi t t service change $50.00 (up to 5 circuits) ❑ Circuits added/al ed without service change $50.00 (6 or m circuits) $7.00 ea ❑ Meter/ t repair $65.00 ❑ Low Voltage systems $55.00 / (alarm, furnace thermostat) PERMIT APPLICATION NOT Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: 1 Date: /9/ 7 Day Telephone: 5 o) Po Z1 > ) GI 2 7 2-4 City State Zap Staff Initials: t /A4 Print Name: Mailing Address: g 3 5 Date Application Expires: r� ( .07 I Date Application Accepted: ( _6- _ H:ApplicationsNForms- Applications On Line\4 -2007 - Electrical Permit Application.doc bh MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea Page 2 of 2 RECEIPT NO: R08 -01576 Initials: WER User ID: 1655 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www. ci. tukwila. wa. us Payee: SIGN -TECH ELECTRIC LLC SET ID: 05 -12 SET NAME: SIGN TECH SET TRANSACTIONS: Set Member Amount EL07 -197 213.20 EL08 -164 500.80 EL08 -197 541.20 TOTAL: 1,255.20 TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description SET RECEIPT Payment Date: 05/12/2008 Total Payment: 1,255.20 Amount Payment Check 5779 1,255.20 TOTAL: 1,255.20 Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 1,255.20 TOTAL: 1,255.20 2338 05/13 9711 TOTAL 1255.20 Receipt No.: R07 -01087 Payee: PRECISION PERMIT SERVICE ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: Permit Number: ELO7 -197 Address: 1004 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 06/08/2007 Applicant: GAMESTOP Issue Date: Initials: WER Payment Date: 06/08/2007 04:04 PM User ID: 1655 Balance: $213.20 TRANSACTION LIST: Type Method Description Amount Payment Check 4578 53.30 Account Code Current Pmts 000.345.832.00.0 53.30 Total: $53.30 Payment Amount: $53.30 9219 06/11 9716 TOTAL 759.98 doc: Receiot -06 Printed: 06 -08 -2007 Project: 6046 510 p Type of Inspe 2too P J Date Called: Special Instructions: I Date Wanted: / h S al. m . Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 X1-01 - PERMIT NO. (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: A Asc 'Inspector: si 'Date: 67 /' S /oV El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedulereinspection. 'Receipt No.: 'Date: Project: 6 Att6 snip Type of Inspection: rOO Address: 241i 4, Date Called: Special Instructions: Date Wanted: j a.m. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 37G104.( STkr—F ?t MDDmo of fjCiQk 0104640( uc,ul' 'Inspector: 'Date: El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: (to- I li PERMIT NO. (206)431 -3670 01 114 I D)r COMMENTS: Type of Inspection: r/44 A-a9 (-LavicAL. koo rex-94 TILE - $urp.e_i- cogPv A-6avC 0' PAUT4-C-0 4- - COIN! 1M A-cf-cos To athPfici.tr CD‘ree izetibucl> _ 5Ect1 e_C nizmAcocrW„ - C4 5de-C M&04 -1"C %ICA/1'0(1J C 64-4 UP tAlaidc or Offe6t6101 akAAsi *r ctiNtici. kliocrLtr,c,tr - F1- 6ofros gelAJI6P 04 ov-ripm Project: c / i Alit ST°P Type of Inspection: zioo Address - 241( 4 0 ts4414, Date Called: Special Instructions: Date Wanted: 6 Requester: Phone No: I INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 El Approved per applicable codes. Inspector: INSPECTION RECORD Retain a copy with permit PERMIT NO. i\lec 113ate: 0 _0 oih (206)431-3670 Corrections required prior to approval. El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be 'paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: 7,! Pgjhc 670/0 Type of Inspection: --- (;3 Address: -6ft 60/Mialti 7 /49X Date Called: Special Instructions: Date Wanted: 6/ a.m. p.m. Requester: Phone No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 Ilnspe pproved per applicable codes. INSPECTION RECORD Retain a copy with permit .407- /Y7 PERMIT NO. g- (206)431-3670 COMMENTS: l en_ a<- ctito6 13 /R44 fUOTT: F 47711445 NO r Ay-40) hti /tea Llij mom Fog /14,_ c/06.1, F/X77/if Corrections required prior to approval. Date /g $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. r eceipt No.: IDate: PPr�ect: l� `I it S / -- e /° Type of Inspection: 7W3 Address: Alt ?6 /4' S/TW Cf IITEA Date Called: Special Instructions: Date Wanted: J . /.2.2 a m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION I 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 OMMENTS: M (rZcA /C /a/(EA ox- ( Abuts /1/4N proved per applicable codes. ❑ Corrections required prior to approval. ( /E- fi �lgi I $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project Info Project ktamest ap Dat 6/22/2007 1004 SOUTKCENTER MALL For Building Department Use FILE • 'S c OD� p C� TUKWI A, WA 98188 Applicant Name: Applicant Address: Applicant Phone: Project Description • New Building • Addition IS Alteration D p ihduded -- - -- � r-rD.._ requirements. Refer to WSEC Section 1513 for contFbis and commissioning Compliance Option O Prescriptive p Lighting Power atowance 0 Systems Analyse A UG (See Qualification Cheddist (over). Indi Prescriptive & LPA spaces dearly on pla s.) Alteration Exceptions (died( appropriate boot -sec. 1132.3) • No changes are being made to the lighting . a 4 • Less than 60% of the fixtures new, installed wattage not increased, & space use n • , . - n gel+, , + lit) Location Description Allowed Watts per ft or per If Area in ft (or If for permeter) Mowed Watts x ft (or x If) Covered Parking (standard paint) •A• - 2X2 02 W 69.0 2346.0 Covered Packing (reflective paint) •c• - 2x4 0.3 Wift2 114.0 RECi -r.\ � . Open Parking •D• - 1x4 0.2 w/rt 71.0 "` Our Areas •s• - DdwNLICELT 02 W/ft 90.0 JUL 2 Bldg. (by facade)' •s• - usTR00M slam 0.25 W/ft 75.0 75.0 Bldg. (by perim) 7.5 W/If + `. Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed •A• - 2X2 34 69.0 2346.0 •c• - 2x4 3 114.0 342.0 •D• - 1x4 17 71.0 1207.0 •s• - DdwNLICELT 5 90.0 450.0 •s• - usTR00M slam 1 75.0 75.0 Location (floor /room no.) Occupancy Description Mowed Wad per ft " Area in ft Mowed x Area RETAIL 1.50 1486.0 2229.0 RZTAIL DISPLAY - MMOTNOT& 810 1.50 1486.0 2229.0 Location Fixture Description . Number of Fixtures Watts/ Fixture Watts Proposed 2004 Washington State Nonresidential Energy Code Compliance Forms 2004 Washington State Nonresidential Energy Code Compliance Form Lighting Summary LTG -SUM Maximum Allowed Lighting Wattage (Interior) Revised May 2005 Total Allowed Watts 4458.0 •' From Table 15-1 (over) - document all exceptions on form LTG -LPA Notes: 1. Use manufacturers listed maximum Input wattage. For hard -wired ballasts only, the default table In the NREC Technical Reference Manual may also be used 2. Include exit lights unless less than 5 watts per fixture. 3. List all fixtures. For exempt lighting, not exception and leave Watts/Fixture blank. Proposed Lighting Wattage (Interior) Total Proposed Watts may not exceed Total Allowed Watts for Interior Allowed • g g Maximum Li tin Wattage Exterior Total Proposed Watts 4420.0 1. Choose either the facade area or the perimeter method, but not both) Total Allowed Watts use mtgr listed maximum Input wattage. tor textures with hard rea masts oruy, Proposed Lighting Wattage (Exterior) the default table in the NREC Technical Reference Manual may also be used. WED d KWI A i 2007 INCOMPLET ��11••• FILE COPY Lighting 2004 Washington State Permit Plans Checklist LTG -CHK NaxesidenUal Energy Code Compliance Forms Revised May 2005 Project Address oamestop (Date 6/22/2007 The following information Is necessary to check a lighting permit application for compliance with the lighting requirements in the 2004 Washington State Nonresidential Energy Code. Applicability I (yes, no, n.a.) Code I Section Component ( I (Information Required Location I on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control/access Schedule with type, indicate locations el yea 1513.2 Area controls Maximum limit per switch E. a.a. 1513.3 Daylight zone control Schedule with type and features, indicate locations n. a. vertical glazing Indicate vertical glazing on plans n. a. overhead glazing Indicate overhead glazing on plans a.a. 1513.4 Display /exhlb/speclal Indicate separate controls 1513.5 Exterior shut-off Schedule with type and features, Indicate location 0.11. (a) timer w /backup Indicate location n.a. (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location n. a. 1513.6.1 (a) occup. sensors Schedule with type and locations n. a. 1513.62 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans a.a. 1513.7 Commissioning Indicate requirements for lighting controls commissioning 11.a. lighting Sum. Fonn Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fiixture n.a. I 1437 IElec motor efficiency iMECH -MOT or Equipment Schedule with hp, rpm, efficiency i I 2004 Washington State Nonresidential Energy Code Compliance Form If "no" is circled for any question, provide explanation: Equipment Schedules The following Information is required to be Incorporated with the mechanical equipment s ules plans. For projects without plans, flit In the required Information below. .5 — Cooling Equipment ' Schedule Equip. ID Brand Name Model No.' Capacity° Btu/h Total CFM OSA CFM or Eton? SEER or EER IPLV' Location VAV -1 Trans vpsf125 1300 a/a return plenum • Heating Equipment Schedule ID Brand Name Model No.' mum Total CFM OSA dm or Econo? Input Btuh Output Btuh Eftidency VAV -1 Trace vpef125 5 kw 1300 n/a Sky • Fan Equipment Schedule E ID ID Brand Name + Model No. 4 CFM SP' HP/BHP Flow Control Location of Service VAT -1 Trans vpef125 1300 0.40 0.50 vav return plenum q c r. r i JUL 2 2004 Washington State Navestden°ai Energy Code Canpllanoe Fame 2004 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary MECH -SUM Revised May 2005 Project Info Project Description Briefly describe mechanical system type and features. Includes Plans Compliance Option Project Address Ganeetop Westfield Soutbcenter Space 1105 Tukwila, WA 96156 Applicant Name: Applicant Address: Applicant Phone: fan powered vav terminal P. t C.. Drawings must contain notes requireing compliance with. commissioning requiremen 0 Simple System Q Complex System Q Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECHSUM for simple Date 6/22/2007 For Building Dept. Use FILE COPY tE available. 2 As tested according to Table 14-1A through 14-1G. ' If required. ' C0P, HSPF, Combustion Efficiency, or AFUE, as applicable. ° Flow control types: variable air valume(VAV), constant volume (CV), or variable speed (VS). FILE COPY INCOMPLETE LTR/L. o NED 7001 Mechanical Permit Plans Checklist MECH -CHK 2004 Wash Ington Slab NanaWWW dray Code CanplwKs Fans Raked bay 2003 Project Address oamestop I°MO 6/22/2007 The following information Is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n a.) ( Code I Section 'Component I I information Required I Location on Plans ` Binding Department I Notes HVAC RE QUIREMENTS (Sections 1401 -1424) 1411 Equipment performance n. a. 1411.4 Pkg. elec. htg.& cg. List heat pumps on schedule yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency Ni n.a. 1411.1 Combustion htg. Indicate intermittent ignition, Sue/draft damper 8 jacket loss 1412 HVAC controls yea 1412.1 Temperature zones indicate locations on plans 41/42 yes 1412.2 Deadbend control indkate 6 degree deadband minimum ate a. a. 1412.3 Humidity control Indicate humidistat yea 1412.4 tic setback indicate thermostat with night setback and 7 riff. day types Na yea 1412.4.1 Dampers indicate damper location and auto. controls & mac leakage Na a. a. 1412.4.2 Optimum Start Indicate optimum start controls n.a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule n. a. 1412.6 Combustion htg. . Indicate modulating or staged control yu 1412.7 Balancing Indicate balancing features on plans yes 1422 Thermostat Interlock Indicate thermostat interlock on plans Na a. a. 1423 Economizers Equipment schedule 1413 Air economizers 1.a. 1413.1 Air Econo Operation indicate 100% capability on schedule a.a. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db 840 deg F wb n.a. 1413.2 Water Econo Doc Indicate dg load 8 water econoe 8 dg tower performance 3.416 1413.3 Integrated operation Indicate capability for partial cooling n.a. 1413.4 Humidification Indicate direct nap or log atomization w/ air economizer 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary Yee 1414.2 Duct insulation Indicate R.value d insulation on duct LICIIN2 Yes 1415.1 Piping I suiaticn Indicate Revalue of Insulation on piping 1416 Completion Requirements Yea 1416.142 Drawings 4 Manuals Indicate requirement for record drawings and operation dorm. us Yee 1416.32 Air Balancing indicate air system balance requirements ire 1.a. 1410.3.3 Hydronic Baia ndrg Indicate hydronic system balance requirements Yee 1416.4 Commissioning indicate requirements for cortrrissiorirg and prelim. Report Ni n.a. 1424 Separate air sys. indicate separate systems on plans Yu I !Mechanical an attached. Equipment schedule with types. I /Sum :nary Form ,input/output, efficiency. dm, hp, economizer I SERVICE WATER HEATING AND HEAi ED POOLS (Sections 1440 - 1454) 1440 Service water htg. n.a. 1441 Elec. water heater Indicate R -10 Insulation under tank Yee 1442 Shut-off controls indicate automatic shut -cif Dl yes 1443 Pipe Insulation Indicate Ft-value of insulation on piping vs n.a. 1452 Heat Pimp COP indicate minimum COP of 4.0 1.a. 1452 Heater Efficiency Indicate pool heater efficiency n.a. 1453 Pool heater controls Indicate switch and 65 degree control n.a. 1454 Pool covers Indicate vapor retardant cover n. a. 1454 Pools 90+ degrees indicate R-12 pod cover If "no" is cfrcied for any question. provide expianation: - 2004 Washington State Nonresidential Energy Code Compliance Form June 19, 2007 Rob Humphrey 833 SE Main St #242 Portland OR 97214 Dear Mr. Humphrey: City of Tukwila RE: Letter of Incomplete Application # 1 Electrical Permit Application EL07 -197 Gamestop —1004 Southcenter Mall Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director This letter is to inform you that your permit application received at the City of Tukwila Permit Center on June 8, 2007 is determined to be incomplete. Before your application can continue the plan review process the following item from the following department needs to be addressed: Building Department: Bill Buterbaugh, at 206 973 -4758, if you have any questions concerning the following comments. 1. Provide WA Non - Residential Lighting Budget. Please address the comment above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that three (3) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messen'er service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, Enclosures File: EL07 -197 P:\Permit Center\Incomplete Letters \2007 Incomplete Ltr #1.DOC )em 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: EL07 -197 DATE: 07 -25 -07 PROJECT NAME: GAMESTOP SITE ADDRESS: 74/, SOUTHCENTER MALL Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: NU 6'I' Buil • ing Division C Public Works Complete Comments: Documents/routing slip.doc 2 -28-02 PERMIT COORD COPY �- PLAN REVIEW /ROUTING SLIP Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: ❑ Permit Coordinator DUE DATE: 07 -31 -07 No further Review Required DATE: DATE: Planning Division n C Not Applicable ❑ DUE DATE: 08-28-07 Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: EL07 -197 DATE: 06 -08 -07 PROJECT NAME: GAMESTOP SITE ADDRESS 1004 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Building Division Public Works Complete APPROVALS OR CORRECTIONS: Documents/routing slip,doc 2 -28 -02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP r L Fire Prevention Incomplete DETERMINATION OF COMPLETENESS: (Tues., Thu s.) Planning Division ❑ Structural ❑ Permit Coordinator Ix DUE DATE: 06 -12 -07 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: I VI la LETTER OF COMPLETENESS MAILED: a Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 07 -10 -07 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: City of Tukwila Department of Community Development 6300 Southeenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 2064313670 Fax 206.4313665 Web site: h tp: / /www.cLtukwlla.waus Revision subririttals must be submitted in person at the Permit Center. Revisions will not be accepted through the mat4 fa , etc.' � Date: 25-- o 9 Plan Check/Permit Number: Response to Incomplete Letter # _ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: l' � C S T 0 F — S o v 4. t M r4 L.L Project Address: IC( S C A T 1+ C AN r E r` Contact Person: Phone Number. s0 3 - 3 - - 5 0 Summary of Revision: .\A/ L t L - 1- - i r» L b c N e Sheet Number(s): N "Cloud" or highlight all areas of revision including date of revision P Received at the City of Tukwila Permit Center by: t Entered in Permits Plus on ni S7() Hppti l[ocau- applications on lineleevision submittal Dested: 843 -2004 Revised: Steven Al. Mullet, Mayor Steve Lancaster, Director EC!WED CITY OF TUKWILA 1 JUL_ 25 2007 Pgnti'T rc ".rcr.. License Information License SIGNTEL988BG Licensee Name SIGN -TECH ELECTRIC LLC Licensee Type ELECTRICAL CONTRACTOR UBI 602152490 Ind. Ins. Account Id Business Type LIMITED LIABILITY COMPANY Address 1 5113 PACIFIC HWY E #12 Address 2 City FIFE County PIERCE State WA Zip 98424 Phone 2539222146 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/7/2002 Expiration Date 1/7/2010 Suspend Date Separation Date Parent Company Previous License Next License Associated License MORRIT *943K6 Look Up a Contractor, Electric or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Electrical Administrator Information License Name Status MORRIT *943K6 MORRISON, TRAVIS ACTIVE Business Owner Information Name MENDENHALL, JOHN C Role PARTNER/MEMBER Effective Date 01/07/2002 Expiration Date MENDENHALL, LINDA D PARTNER/MEMBER 01/07/2002 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= SIGNTEL988BG 05/12/2008 SYMBOL LEGEND -e4)1§1440 r OQ 0 don®IJm:g) UNIPLEX RECEPTACLE (SINGLE) DUPLEX RECEPTACLE DUPLEX ISOLATED GROUND QUADPLEX RECEPTACLE QUADPLEX ISOLATED GROUND TELEPHONE OUTLET JUNCTION BOX DATA OUTLET DOORBELL PUSHBUTTON DOORBELL DOORBELL LOW —VOLT TRANS LOW — VOLTAGE TRANSFORMER DISCONNECT SWITCH TELEPHONE BOARD ELECTRICAL PANEL KVA TRANSFORMER T/c 24HR 7 DAY- -TIME CLOCK $ WALL SWITCH 3 #12, 3/4 "C (2 CKT WIRES, 1 NEUTRAL, 1 GROUND) II if ---- CIRCUIT HOME RUN — — — — CONDUIT THRU /BELOW FLOOR 0— CONDUIT STUBBED UP /DOWN e N.L NIGHT UGHT VIA T/C TIMECLOCK CONTROLED CIRCUIT CONDUIT RUNS IN CABINET BASE FROM WALL TO ELEC PANEL GYP. FRAMING DUPLEX MTD 48" A.F.F. TELEPHONE JACKS QUAD RECE I SOLATED QUAD RECEPT COAX OUTLET QUAD RECEPT CASHWRAP ELEVATION SCALE ve - ra SINGLE PLUG RECEPTACLE HUBBELL #5261 IVORY. JUNCTION BOX WITH SINGLE COAXIAL OUTLET. TO CASH /WRAP UNISTRUT n GYP. CEILING f LUCASEY SUSPENDED N MONITOR FRAME MONFEOR'S DEVICE DETAIL SCALE 8' 1-0' NOTE: OUTLET COVERS TO MATCH CEILING COLOR. POWER PLAN SCALE V4 M O2 LP -2 �4 PHONE LINE CASHWRAP POWER SCALE us - ra DUPLEX MTD HORIZONTAL- CA3HWRAP ELEVATION SCALE 1/4 • 1-0' EQ. EQ LP - 6 cc REVIEWED FOR CO NFPAOO P NEC � AUG - 2 2�00� l�k" City Of Tukwila B ILDTNG D ION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. SEPARATE PERMIT REQUIRED FOR: EiNethanical Electrical UAPiontdng IGas Piping City of Tukwila BUILDING DIVISION POWER KEYED NOTES Q E.C. SHALL INSTALL DISCONNECT SWITCH FOR SIGNAGE CIRCUITS) AS to RREQUEQUIRED IRED BY N.E.C. 600. REFER TO PLANS FOR NUMBER OF CIRCUITS . THE CIRCUITS USED TO POWER THE ELECTRONIC CASH REGIS ENS SHALL 2 N±J NOT BE USED FOR ANY OTHER PURPOSE. CIRCUITS SHALL NOT SHARE NEUTRAL OR GROUND WITH OTHER EQUIPMENT. SEPARATE POWER, NEUTRAL, AND INSULATED GROUND WIRES, MINIMUM SIZE #12 AWG SHALL BE RUN TO THE CIRCUIT BREAKER PANEL BOARD WHERE GROUND WIRE SHALL BE TIED TO THE GROUND TERMINAL ISOLATED FROM NEUTRAL. DO NOT USE CONDUIT FOR GROUNDING AS THIS MAY NOT BE CONTINUOUS. CASH REGISTER CIRCUIT SHALL BE RUN IN SEPARATE CONDUIT. RECEPTACLES SHALL BE HUBBELL #IG -5362. 3 PROVIDE CONDUIT AND WIRE FOR POWER TO P.O.S. AND GENERAL RECEPTACLES AND TELEPHONE AND COAX OUTLETS TO BE LOCATED AT CABINET BOTTOM. ROUTE CONDUITS AS SHOWN ON PLAN DOWN WALL OR COLUMN AND LEAVE A (12) TWELVE FOOT FLEX WHIP FOR EACH POWER CIRCUIT CONDUIT REQUIRED. STUB CONDUIT INTO CABINET BASE AND RUN THROUGH CABINET BASE TO EACH RECEPTACLE. COORDINATE EXACT CONFIGURATION WITH TENANT REP. AND LOCATION WITH FIXTURE INSTALLER. /I\ E.C. SHALL PROVIDE 3/4" CONDUIT WITH PULLWIRE FROM CASH /WRAP TO TELEPHONE BACKBOARD IN STOCKROOM 5 E.C. SHALL FIELD VERIFY EXACT REQUIREMENTS FOR SMOKE /FIRE ALARM 5 SYSTEM. REUSE ANY EXISTING DETECTION SYSTEM. REPLACE ANY DEFECTIVE DEVICES. IF THERE IS NOT AN EXISTING SYSTEM, E.C. SHALL SUPPLY AND INSTALL ALL NECESSARY EQUIPMENT (SMOKE DETECTORS, AUDIO /VISUAL ALARMS, FIRE ALARM PANEL, CONDUIT, WIRE, ETC.) FOR A NEW SYSTEM AS MAY BE REQUIRED BY LANDLORD AND /OR LOCAL FIRE MARSHALL INSTALL SMOKE DETECTORS IN SUPPLY OR RETURN DUCTWORK AS REQUIRED BY LOCAL AUTHORITY. FIELD VERIFY AND COORDINATE. DUPLEX RECEPTACLE FLUSH MOUNTED IN CEILING PER N.E.C. 210 -62. DUPLEX RECEPTACLE FLUSH MOUNTED VERTICAL IN WALL AT 15" A.F.F. 7 (18" A.F.F. IN CALIFORNIA) FOR GENERAL USE. UNIPLEX RECEPTACLE FLUSH MOUNTED IN CEILING FOR MONITORS. REFER TO DETAIL THIS SHEET. COAX OUTLET FLUSH MOUNTED IN CEILING FOR MONITORS. ROUTE 3/4" CONDUIT WITH RG59U COAX CABLE FROM MONITOR LOCATIONS BACK TO CASH /WRAP CABINET "Q" FOR VCR. REFER TO DETAIL THIS SHEET. 10 DUPLEX RECEPTACLE FLUSH MOUNTED VERTICAL IN WALL AT 100" A.F.F. 11 DUPLEX RECEPTACLE FLUSH MOUNTED VERTICAL IN WALL AT 108" A.F.F. FOR SECURITY SYSTEM. QUADPLEX RECEPTACLE MOUNTED IN WALL AT 48" A.F.F. 13 DUPLEX RECEPTACLE AND PHONE OUTLET MOUNTED AT 42" A.F.F. FOR MANAGERS DESK. 14 G.F.C.I. DUPLEX RECEPTACLE FLUSH MOUNTED AT 42" A.F.F. 15 G.F.C.I. RECEPTACLE MOUNTED BELOW LAV. FOR INSTANTANEOUS TYPE WATER HEATER. 1 RECEPTACLE AND SWITCHED LIGHT PROVIDED BY E.C. TO BE INSTALLED PER N.E.C. 210 -63 AND 210 -70c 17 FIELD VERIFY EXACT LOCATION OF LANDLORD TELEPHONE SERVICE STUB—IN AND EXTEND AS REQUIRED FOR CONNECTION TO TENANT TELEPHONE EQUIPMENT. PROVIDE 3/4" PLYWOOD BACKBOARD FOR MOUNTING OF NEW ELECTRICAL AND TELEPHONE EQUIPMENT. SIZE AND SECURE AS REQUIRED. PROVIDE ISOLATED GROUND DUPLEX RECEPTACLE FOR POWER TO TELEPHONE EQUIPMENT. PANEL "LP ". REFER TO PANEL SCHEDULE. PANEL "MP ". REFER TO PANEL SCHEDULE. TRANSFORMER. REFER TO ONE —UNE DIAGRAM FILE COPT _�. Permit No Nan review approval Is subject to errors and omissions. Approval of cene documents does not authorize the violatic C; En 4=e.zed code or ordinance. Receipt of approved ;:';i Cpl ° -'l 'ond:dons is adnotvledged; City of Tukwila BUILDING DIVISION Public Works, Building Division PERMIT NUMBER FILE COPY jLO 19 7 RECEIVE : JUN - 8 2007 PERMIT CENTEI GENERAL ELECTRICAL NOTES 1. ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND SHALL IMMEDIATELY NOTIFY THE OWNER'S PROJECT MANAGER OF ANY DISCREPANCIES. 2. ALL CONDUITS ARE TO BE CONCEALED IN WALLS OR ABOVE CEILINGS. CONDUITS IN EXPOSED CEILING AREAS SHALL EXIT WALLS AS CLOSE TO ROOF /FLOOR STRUCTURAL DECK 'AS POSSIBLE. 3. ANY EXISTING MATERIALS OR EQUIPMENT NOT TO BE REUSED MUST BE COMPLETELY REMOVED AND DISPOSED OF PROPERLY THROUGH THE LANDLORD'S DESIGNATED AND APPROVED HAULER. NO EQUIPMENT OR COMPONENTS MAY BE ABANDONED WITHOUT WRITTEN PERMISSION OF THE LANDLORD. 4. ANY PENETRATIONS THROUGH FIRE RATED WALLS NEED TO BE APPROPRIATELY ARE STOPPED TO RETAIN THE WALL'S RATING. 5. CONTRACTOR SHALL ENSURE LOADS BETWEEN PHASES ON PANEL BOARDS ARE BALANCED WITHIN 10%. 6. ALL LOW VOLTAGE WIRING IN CEILING PLENUM (INCLUDING TELEPHONE. DATA, ALARM AND TEMP. CONTROL WIRING) SHALL BE UL LISTED TEFLON PLENUM CABLE. sk a e e a a a a a I a a e a e =I a a EM a a Effl e ® e e 11 EM a CONDUIT RUNS IN CABINET BASE FROM WALL TO ELEC PANEL GYP. FRAMING DUPLEX MTD 48" A.F.F. TELEPHONE JACKS QUAD RECE I SOLATED QUAD RECEPT COAX OUTLET QUAD RECEPT CASHWRAP ELEVATION SCALE ve - ra SINGLE PLUG RECEPTACLE HUBBELL #5261 IVORY. JUNCTION BOX WITH SINGLE COAXIAL OUTLET. TO CASH /WRAP UNISTRUT n GYP. CEILING f LUCASEY SUSPENDED N MONITOR FRAME MONFEOR'S DEVICE DETAIL SCALE 8' 1-0' NOTE: OUTLET COVERS TO MATCH CEILING COLOR. POWER PLAN SCALE V4 M O2 LP -2 �4 PHONE LINE CASHWRAP POWER SCALE us - ra DUPLEX MTD HORIZONTAL- CA3HWRAP ELEVATION SCALE 1/4 • 1-0' EQ. EQ LP - 6 cc REVIEWED FOR CO NFPAOO P NEC � AUG - 2 2�00� l�k" City Of Tukwila B ILDTNG D ION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. SEPARATE PERMIT REQUIRED FOR: EiNethanical Electrical UAPiontdng IGas Piping City of Tukwila BUILDING DIVISION POWER KEYED NOTES Q E.C. SHALL INSTALL DISCONNECT SWITCH FOR SIGNAGE CIRCUITS) AS to RREQUEQUIRED IRED BY N.E.C. 600. REFER TO PLANS FOR NUMBER OF CIRCUITS . THE CIRCUITS USED TO POWER THE ELECTRONIC CASH REGIS ENS SHALL 2 N±J NOT BE USED FOR ANY OTHER PURPOSE. CIRCUITS SHALL NOT SHARE NEUTRAL OR GROUND WITH OTHER EQUIPMENT. SEPARATE POWER, NEUTRAL, AND INSULATED GROUND WIRES, MINIMUM SIZE #12 AWG SHALL BE RUN TO THE CIRCUIT BREAKER PANEL BOARD WHERE GROUND WIRE SHALL BE TIED TO THE GROUND TERMINAL ISOLATED FROM NEUTRAL. DO NOT USE CONDUIT FOR GROUNDING AS THIS MAY NOT BE CONTINUOUS. CASH REGISTER CIRCUIT SHALL BE RUN IN SEPARATE CONDUIT. RECEPTACLES SHALL BE HUBBELL #IG -5362. 3 PROVIDE CONDUIT AND WIRE FOR POWER TO P.O.S. AND GENERAL RECEPTACLES AND TELEPHONE AND COAX OUTLETS TO BE LOCATED AT CABINET BOTTOM. ROUTE CONDUITS AS SHOWN ON PLAN DOWN WALL OR COLUMN AND LEAVE A (12) TWELVE FOOT FLEX WHIP FOR EACH POWER CIRCUIT CONDUIT REQUIRED. STUB CONDUIT INTO CABINET BASE AND RUN THROUGH CABINET BASE TO EACH RECEPTACLE. COORDINATE EXACT CONFIGURATION WITH TENANT REP. AND LOCATION WITH FIXTURE INSTALLER. /I\ E.C. SHALL PROVIDE 3/4" CONDUIT WITH PULLWIRE FROM CASH /WRAP TO TELEPHONE BACKBOARD IN STOCKROOM 5 E.C. SHALL FIELD VERIFY EXACT REQUIREMENTS FOR SMOKE /FIRE ALARM 5 SYSTEM. REUSE ANY EXISTING DETECTION SYSTEM. REPLACE ANY DEFECTIVE DEVICES. IF THERE IS NOT AN EXISTING SYSTEM, E.C. SHALL SUPPLY AND INSTALL ALL NECESSARY EQUIPMENT (SMOKE DETECTORS, AUDIO /VISUAL ALARMS, FIRE ALARM PANEL, CONDUIT, WIRE, ETC.) FOR A NEW SYSTEM AS MAY BE REQUIRED BY LANDLORD AND /OR LOCAL FIRE MARSHALL INSTALL SMOKE DETECTORS IN SUPPLY OR RETURN DUCTWORK AS REQUIRED BY LOCAL AUTHORITY. FIELD VERIFY AND COORDINATE. DUPLEX RECEPTACLE FLUSH MOUNTED IN CEILING PER N.E.C. 210 -62. DUPLEX RECEPTACLE FLUSH MOUNTED VERTICAL IN WALL AT 15" A.F.F. 7 (18" A.F.F. IN CALIFORNIA) FOR GENERAL USE. UNIPLEX RECEPTACLE FLUSH MOUNTED IN CEILING FOR MONITORS. REFER TO DETAIL THIS SHEET. COAX OUTLET FLUSH MOUNTED IN CEILING FOR MONITORS. ROUTE 3/4" CONDUIT WITH RG59U COAX CABLE FROM MONITOR LOCATIONS BACK TO CASH /WRAP CABINET "Q" FOR VCR. REFER TO DETAIL THIS SHEET. 10 DUPLEX RECEPTACLE FLUSH MOUNTED VERTICAL IN WALL AT 100" A.F.F. 11 DUPLEX RECEPTACLE FLUSH MOUNTED VERTICAL IN WALL AT 108" A.F.F. FOR SECURITY SYSTEM. QUADPLEX RECEPTACLE MOUNTED IN WALL AT 48" A.F.F. 13 DUPLEX RECEPTACLE AND PHONE OUTLET MOUNTED AT 42" A.F.F. FOR MANAGERS DESK. 14 G.F.C.I. DUPLEX RECEPTACLE FLUSH MOUNTED AT 42" A.F.F. 15 G.F.C.I. RECEPTACLE MOUNTED BELOW LAV. FOR INSTANTANEOUS TYPE WATER HEATER. 1 RECEPTACLE AND SWITCHED LIGHT PROVIDED BY E.C. TO BE INSTALLED PER N.E.C. 210 -63 AND 210 -70c 17 FIELD VERIFY EXACT LOCATION OF LANDLORD TELEPHONE SERVICE STUB—IN AND EXTEND AS REQUIRED FOR CONNECTION TO TENANT TELEPHONE EQUIPMENT. PROVIDE 3/4" PLYWOOD BACKBOARD FOR MOUNTING OF NEW ELECTRICAL AND TELEPHONE EQUIPMENT. SIZE AND SECURE AS REQUIRED. PROVIDE ISOLATED GROUND DUPLEX RECEPTACLE FOR POWER TO TELEPHONE EQUIPMENT. PANEL "LP ". REFER TO PANEL SCHEDULE. PANEL "MP ". REFER TO PANEL SCHEDULE. TRANSFORMER. REFER TO ONE —UNE DIAGRAM FILE COPT _�. Permit No Nan review approval Is subject to errors and omissions. Approval of cene documents does not authorize the violatic C; En 4=e.zed code or ordinance. Receipt of approved ;:';i Cpl ° -'l 'ond:dons is adnotvledged; City of Tukwila BUILDING DIVISION Public Works, Building Division PERMIT NUMBER FILE COPY jLO 19 7 RECEIVE : JUN - 8 2007 PERMIT CENTEI GENERAL ELECTRICAL NOTES 1. ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND SHALL IMMEDIATELY NOTIFY THE OWNER'S PROJECT MANAGER OF ANY DISCREPANCIES. 2. ALL CONDUITS ARE TO BE CONCEALED IN WALLS OR ABOVE CEILINGS. CONDUITS IN EXPOSED CEILING AREAS SHALL EXIT WALLS AS CLOSE TO ROOF /FLOOR STRUCTURAL DECK 'AS POSSIBLE. 3. ANY EXISTING MATERIALS OR EQUIPMENT NOT TO BE REUSED MUST BE COMPLETELY REMOVED AND DISPOSED OF PROPERLY THROUGH THE LANDLORD'S DESIGNATED AND APPROVED HAULER. NO EQUIPMENT OR COMPONENTS MAY BE ABANDONED WITHOUT WRITTEN PERMISSION OF THE LANDLORD. 4. ANY PENETRATIONS THROUGH FIRE RATED WALLS NEED TO BE APPROPRIATELY ARE STOPPED TO RETAIN THE WALL'S RATING. 5. CONTRACTOR SHALL ENSURE LOADS BETWEEN PHASES ON PANEL BOARDS ARE BALANCED WITHIN 10%. 6. ALL LOW VOLTAGE WIRING IN CEILING PLENUM (INCLUDING TELEPHONE. DATA, ALARM AND TEMP. CONTROL WIRING) SHALL BE UL LISTED TEFLON PLENUM CABLE. a b c d ❑ ❑ I ❑ LP -7 LP -3 LP -5 LP -9 SALES SALES WALLWASH STOCK 2x2 2x2 1x4 2x4 LIGHTING LIGHTING LIGHTING LIGHTING TYPE 'D' TYPICAL ME ■■■ a Uhl MEI ■.E a U ' ■1R1 ■■S ■.■ IUI NEM ■. LP=TT REC TYPI UGH11NG PLAN SCALE v< • ra TYPE 'D' TYPICAL TYPE 'A' TYPICAL TYPE 'F' TYPICAL UGHT FIXTURE SCHEDULE QTY SYMBOL TYPE MANUFACTURER CATALOG NO. DESCRIPTION NOTES VOLTS REC SUR PEN WAL 34 3 17 5 2 1 ••• w•-U-. CI 0 N A B C D E F G x Z LIGHTOLIER UGHTOUER LIGHTOLIER LIGHTOLIER LIGHTOLIER LIGHTOLI LIGHTOUER SURE —UTES BROAN PLA2G9LSU6SO PLA2G18LS440S0 PRA2GREVA 43250 —EM WLRN224 WLRN124 1102P1/1113 SW24ORSSO LPX- 70 —RWH 696 2x2 FLUORESCENT WITH PARABOLIC LOUVER 2x4 FLUORESCENT WITH PARABOLIC LOUVER 2x4 FLUORESCENT WITH ACRYLIC LENS 1x4 COMPACT FLUORESCENT WALLWASHER 1x2 COMPACT FLUORESCENT WALLWASHER DOWNLIGHT WITH SPECULAR CLEAR REFLECTOR 4' FLUORESCENT OPEN LAMP STRIPUGHT UNIVERSAL MOUNT L.E.D. EXIT WITH INTERNAL BATTERY COMBINATION LIGHT AND EXHAUST FAN 1,2,3,4 1,2,3,4 1,2,3,4 1,2 1,2 1 1,2,3,4,5 1 1 120 120 120 120 120 120 120 120 120 X X X X X X X X X LAMP/ WATTS/ FIXTURE MANUFACTURER/ FTXT LAMP WATTS CATALOG NO. 2 4 4 2 1 1 2 1 LAMP SCHEDULE 32 32 32 40 40 90 32 75 69 114 114 71 36 90 62 3 180 SYLVANIA FB032/835/6 SYLVANIA F032/835 SYLVANIA F032/835 SYLVANIA FT40DL /835/RS SYLVANIA FT4ODL /835/RS SYLVANIA PAR38 /CAP /SPL /FL SYLVANIA F032/835 LE. D. SYLVANIA 75A /HAL /RP 1. FIXTURES AND LAMPS SUPPLIED BY TENANT AND INSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. 2. EQUIP NEW FLUORESCENT LIGHT FIXTURES WITH ELECTRONIC BALLASTS. 3. FIXTURES SHOWN WITH CROSS—HATCH ARE TO BE NIGHT LIGHTS WITH EMERGENCY BATTERY BALLAST. 4. FIXTURES USED FOR EXIT, EMERGENCY, OR NIGHT LIGHTING TO BE ON LOCKOUT CIRCUIT. 5. UGHT FIXTURES TO BE CHAIN HUNG AT 10' -0" A.F.F. WHEN NO CEILING IS PRESENT. SURFACE MOUNT IF CEILING PRESENT. 6. GENERAL CONTRACTOR SHALL CLEAN AND RELAMP EXISTING FIXTURES TO REMAIN TO LIKE —NEW CONDITION. FIELD VERIFY LAMP TYPE. REVIEWED FOR CODE PA 70 - NEC 1V� AUG - 2 2001 City �8f Tu1cw� ILD.NG DIVI S10N CONTRACTOR TO VERIFY EXACT CONFIGERATION REQUIRED WITH SPACE AVAILABLE. PROVIDE LABELS AS DIRECTED BY OWNER. SWITCHES SHALL NOT BE MOUNTED HIGHER THAN 48" SWflCH BANK ecu.s NONE LOi LR7 7ECIVED JUN - 8 2007 PERMIT CENTEE CasIERAL ELECTRICAL NOTES 1. ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND SHALL IMMEDIATELY NOTIFY THE OWNER'S PROJECT MANAGER OF ANY DISCREPANCIES. 2. ALL CONDUITS ARE TO BE CONCEALED IN WALLS OR ABOVE CEILINGS. CONDUITS IN EXPOSED CEIUNG AREAS SHALL EXIT WALLS AS CLOSE TO ROOF /FLOOR STRUCTURAL DECK AS POSSIBLE. 3. ANY EXISTING MATERIALS OR EQUIPMENT NOT TO BE REUSED MUST BE COMPLETELY REMOVED AND DISPOSED OF PROPERLY THROUGH THE LANDLORD'S DESIGNATED AND APPROVED HAULER. NO EQUIPMENT OR COMPONENTS MAY BE ABANDONED WITHOUT WRITTEN PERMISSION OF THE LANDLORD. 4. ANY PENETRATIONS THROUGH FIRE RATED WALLS NEED TO BE APPROPRIATELY FIRE STOPPED TO RETAIN THE WALL'S RATING. 5. CONTRACTOR SHALL ENSURE LOADS BETWEEN PHASES ON PANEL BOARDS ARE BALANCED WITHIN 10 %. 6. ALL LOW VOLTAGE WIRING IN CEIUNG PLENUM (INCLUDING TELEPHONE. DATA, ALARM AND TEMP. CONTROL WIRING) SHALL BE UL LISTED TEFLON PLENUM CABLE. PANELBOARD DESIGNATION 120/208 VOLTS DESIGNATION 9M s L NEW SURFACE INSTALL % AMPERE EXIST BUS LOCATION 100 RELOCATED EXIST 3 PHASE FED X 4 WIRE, SOLID NEUTRAL MTD AMPERE MAIN BEAKER TOP FED BOTTOM FLUSH MTD CKT # LOAD WIRE BRKR J DESCRIPTION WATTS TYPE SIZE SIZE `a! A B C I 310d BRKR SIZE CKT DESCRIPTION WATTS LOAD WIRE WATTS TYPE: SIZE BRKR J SIZE a A B C |0 BRKR SIZE WIRE SIZE LOAD TYPE WATTS DESCRIPTION C 1 El SIGN-STOREFRONT 1200 12 20 1 2280 20p. 2379 .-M. 1 20 12 R 1080 REC-- P.O.S. 2 4 7666 LTG - STOREFRONT 5 7 9 11 13 15 17 450 L ® 1890 � '- 1 20 12 R 1440 REC - CASHWRAP 4 ilumggig 7 MEOW111.1 ' '� > r %' H f T - - . Ar ✓... ".:z w.�fx rY 1035 L 12 ® 1 - 20 12 R 180 REC- BACKWRAP 6 20 1 W 20 1 • 1644 1104 L 12 - - 1 20 12 R 540 REC- SECURITY 8 - -- IMUM 9 m EllEMEZZEZEMIE ® MI 19 21 23 25 29 OBEEMIDEMIIIII 1207 L ® E� 12 1 4 16 1 8 1 20 12 R 360 REC - STOREFRONT 10 20 1567 25% LTG AND SIGN 1433 7770 LTG -STOCK 408 1111 12 BALANCE LOAD 22798 DEMAND LOAD 24770 CONNECTED 1 20 12 R 360 REC- MONITORS 12 20 1 768 327 L ® 1 20 - - -- SPARE 14 20 1 Eel 10 80 SPARE -- - Mel O 4- r/ v ~g } t Ewa I u iiII 1 20 12 R 1080 REC - CEILING 16 - SPARE m . 1 20 12 R 1200 REC - MANAGERS DESK 18 IIII ' 1200 ; , : 1140 ' b - - 1 1 20 12 Q 1140 REC -STOCK HVAC 20 -50 - 20 ®© 750 WATER HEATER 360 = - - 144 EMI 1 20 12 © 360 PHONE CLOCK ® I -1 -I -I 20 20 20 BM -- SPARE ©� 1� RECR -G EN ENERAL 26 30 • . 25% LTG AND SIGN 1433 SUB TOTALS R = RECEPTACLE E M = MISCELLANEOUS H = H.V.A.C. K = KITCHEN 5391 1 5287 4983 DEMAND LOAD 17094 CONNECTED PHASE BALANCE LOAD 15661 DEMAND AMPERES 47.5 7.6% PANELBOARD 2nmao DESIGNATION 9M NEW SURFACE INSTALL 100 X EXIST BUS LOCATION 100 RELOCATED EXIST VOLTS 3 PHASE 4 WIRE, SOLID NEUTRAL AMPERE AMPERE MAIN BREAKER TOP FED X BOTTOM FED FLUSH MTD MTD X. CKT # LOAD WIRE BRKR J DESCRIPTION WATTS TYPE SIZE SIZE `a! A B C I 310d BRKR SIZE WIRE SIZE: LOAD TYPE WATTS DESCRIPTION CKT 1 2379 H 12 15 3 7770 li 3 50 * - 5391 TRANSFORMER 2 3 2379 .-M. 5287 4 7666 5 7 9 11 13 15 17 11111 2379 -.., � '- 4983 6 . 7362 MEOW111.1 ' '� > r %' H f T - - . Ar ✓... ".:z w.�fx rY - - ---- SPARE 8 - - --- SPARE 10 - - -- IMUM fl!U k� x> . I g \ ~ k NA -- :7 vv���� g Y.f /Lro� ,�- SPARE . �: ; i }r G :a . "... ' . , ' R..6a':L .. G :R fF � � ' 3 . h .> � ,= 12 1 4 16 1 8 �m -- .i:'EY s: , "£,-= SUB TOTALS L = LTG OR SIGNAGE R = RECEPTACLE H = MISCELLANEOUS K = K K = KITCHEN N 25% LTG AND SIGN 1433 7770 7666 7362 25% LARGEST MOTOR 541 BALANCE LOAD 22798 DEMAND LOAD 24770 CONNECTED DEMAND AMPERES 29.8 PHASE 5.3X GENERAL ELECTRICAL SPECIFICATIONS 1. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL MINOR ITEMS WHICH ARE OBVIOUSLY AND REASONABLY NECESSARY FOR COMPLETION. 2. ALL WORK AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND STATE AND LOCAL CODES THAT APPLY. 3. THE CONTRACTOR SHALL TAKE OUT PERMITS, PROCURE CERTIFICATES AND PAY ALL FEES CONNECTED THEREWITH. 4. BIDDERS SHALL VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH ALL CONDITIONS SURROUNDING THE WORK. 5. THE CONTRACTOR IS REFERRED TO THE ARCHITECTURAL, STRUCTURAL AND MECHANICAL PLANS AND SPECIFICATIONS AND TO LANDLORD'S LEASE AGREEMENT. SUCH PLANS AND SPECIFICATIONS ARE CONTRACT DOCUMENTS. 6. DRAWINGS ARE DIAGRAMMATIC AND INTENDED TO SHOW APPROXIMATE LOCATIONS. 7. UNLESS OTHERWISE NOTED, ALL MATERIALS SHALL BE NEW. 8. ALL LIGHT FIXTURES AND LAMPS ONLY, FURNISHED BY THE TENANT. ALL STEMS AND OTHER MOUNTING ACCESSORIES AND INSTALLATION BY EC. 9. THIS SHALL TOUCH UP OR REFINISH THE INISH OF EQUIPMENT MARRED DURING SHIPMENT OR INSTALLATION. 10. THE SHALL FIELD VERIFY ALL CONDITIONS _ IMMEDIATELY NOTIFY THE OWNER'S PROJECT MANAGER OF ANY DISCREPANCIES. 11. THE SHALL BE A LICENSED MASTER ELECTRICIAN OF THE STATE IN WHICH THE JOB IS LOCATED. 12. THE INSTALLATION SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR. 13. NO INTERRUPTION OF BUILDING FUNCTIONS OR ELECTRICAL SERVICE SHALL BE PERMITTED WITHOUT APPROVAL OF THE OWNER'S PROJECT MANAGER. 14. ELECTRICAL WORK SHALL NOT INTERFERE WITH CLEARANCES REQUIRED FOR GENERAL AND MECHANICAL CONSTRUCTION. SHOULD ELECTRICAL WORK BE INSTALLED WHICH INTERFERES WITH THE WORK OF THE OTHER CONTRACTORS, SUCH WORK SHALL BE CHANGED AT NO ADDITIONAL COST TO THE 15. THE CONTRACTOR TO DO ALL CUTTING AND PATCHING REQUIRED TO INSTALL ANY PORTION OF THIS WORK. PATCH WITH NEW MATERIALS OF THE SAME TYPE THAT WAS REMOVED. REFINISH PATCH SURFACE TO MATCHING EXISTING ADJACENT SURFACES. 16. GROUNDING SHALL COMPLY WITH THE CODE AND REQUIREMENTS OF THE UTILITY COMPANY SERVING THE PROJECT. 17. AT THE COMPLETION OF THE WORK, THE CONTRACTOR SHALL REMOVE ALL RUBBISH CAUSED BY THEIR WORK AND SHALL THOROUGHLY CLEAN ALL EQUIPMENT. 18. ALL WORK SHALL BE GUARANTEED FREE FROM DEFECTS FOR A PERIOD OF ONE YEAR (OR STATUTORY LIMIT IF GREATER) FROM DATE OF FINAL COMPLETION OR FULL OCCUPANCY. SEE GENERAL CONDITIONS. 19. ALL ITEMS OF ELECTRICAL EQUIPMENT ASSOCIATED WITH THE CONTROL OF ELECTRICAL APPARATUS SHALL BE IDENTIFIED WITH ENGRAVED BAKELITE NAMEPLATES, I.E.: PANELBOARDS, DISCONNECT SWITCHES, CONTACTORS, ETC. 20. NOMINAL MOUNTING HEIGHT OF DEVICES IN EXPOSED CONCRETE BLOCK, TILE OR BRICK WALLS SHALL ALL OCCUR WITHIN A STRUCTURAL COURSE. A MINIMUM AMOUNT OF BLOCK, TILE OR BRICK WALL SHALL BE CUT. 21. ALL ELECTRICAL EQUIPMENT SHALL BE SPECIFICATION GRADE AND UL APPROVED, UNLESS SPECIFIED OTHERWISE. 22. WIRING DEVICES SHALL MEET NEMA PERFORMANCE STANDARDS WE -1 1965. MINIMUM SIZE OF OUTLET BOXES SHALL BE 4" TRADE. 23. ALL CONDUCTORS SHALL BE COPPER, 600V -THHN, THWN OR XHHW, #12 MINIMUM SIZE. ALUMINUM WIRE SHALL NOT BE PERMITTED. USE 150'C. WIRE FOR ALL INCANDESCENT FIXTURES THAT ARE NOT PREWIRED. USE 90'C. WIRE FOR FIXTURE WIRING OR BRANCH CIRCUIT WIRING RUNNING PAST A FLUORESCENT BALLAST. 24. ALL ELECTRICAL WIRING MUST BE IN CONDUIT, MINIMUM SIZE 3/4 ". ROMEX, METAL -CLAD CABLE, BX, ELECTRICAL NON- METALLIC TUBING (ENT) ETC., SHALL NOT BE PERMITTED. 25. NO CONDUITS TO BE RUN IN OR SUPPORTED BY DUCTWORK. A PULL WIRE SHALL BE INSTALLED IN ALL EMPTY CONDUITS. 26. ALL CONDUITS THROUGH ROOF SHALL PENETRATE ROOF USING PROPER APPROVED ROOF FLASHING. 27. FLEXIBLE CONDUIT CAN ONLY BE USED FOR SHORT FINAL CONNECTIONS TO INTERIOR UGHTING FIXTURES AND EQUIPMENT. 28. ALL ELECTRICAL EQUIPMENT AND CONDUIT EXPOSED TO WEATHER SHALL BE WEATHERPROOF AND CONDUIT EXPOSED TO WEATHER OR IN CONTACT WITH CONCRETE SHALL BE GALVANIZED HEAVY WALL STEEL 29. FUSES SHALL BE BUSSMANN "LOW -PEAK" DUAL ELEMENT, CLASS RK 1. 30. PROVIDE TYPEWRITTEN INDEX CARDS FOR ALL PANELS. 31. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF CEILING CONSTRUCTION BEFORE INSTALLING LIGHT FIXTURES. 32. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY BALANCING ALL BRANCH CIRCUITS AMONG THE PHASES OF THE SYSTEM. 33. PANELBOARDS SHALL HAVE BUS RATING AND A.I.C. RATING GREATER THAN FAULT CURRENT VALUE AT POINT OF APPLICATION. 34. CIRCUIT BREAKERS USED FOR LIGHT SWITCHING SHALL BE UL LISTED "SWITCHING DUTY BREAKERS ". 35. PROVIDE LOCK -ON CUP TO BREAKERS FOR CASH REGISTERS, MODEMS, EXIT LIGHTS AND EMERGENCY BATTERY CIRCUITS IN "ON" POSITION. 36. SWITCHES AND RECEPTACLES SHALL BE HUBBELL OR SLATER WITH HUBBELL NUMBERS USED TO SPECIFY TYPE USED. SWITCHES SHALL BE IVORY COLOR, 20 AMP, 120/277 VOLT A.C. RATED: SINGLE POLE SWITCHES SHALL BE #1221 AND 3 -WAY SWITCHES SHALL BE #1223. RECEPTACLES SHALL BE IVORY COLOR 20 AMP GROUNDING TYPE #5362. WALL PLATES SHALL BE IVORY COLORED, UNLESS NOTED OTHERWISE. 37. TELEPHONE OUTLETS SHALL HAVE 3/4" EMPTY CONDUIT RUN TO TELEPHONE TERMINAL 38. ELECTRICAL CONTRACTOR SHALL FURNISH TEMPORARY ELECTRICAL SERVICE AND REMOVE ALL TEMPORARY WIRING WHEN TENANT'S PERMANENT SERVICE AND WIRING ARE COMPLETE. 39. ALUMINUM CONDUIT, IF USED, SHALL BE BONDED AT EACH POINT IT ENTERS A STEEL RACEWAY, JUNCTION BOX OR PULL BOX WITH AN APPROVED GROUND BUSING AND BARE COPPER CONDUCTORS SIZED IN ACCORDANCE WITH ART. 250 -95 OF THE NEC. ALUMINUM CONDUIT SHALL NOT BE INSTALLED UNDERGROUND OR IN CONTACT WITH CONCRETE. ANTISEIZING COMPOUND SHALL BE APPUED TO ALL THREADS. 40. SFALTTFE OR UQUIDTITE FLEXIBLE CONDUIT SHALL NOT EXCEED 6 FOOT IN LENGTH AND SHALL HAVE A COPPER GROUNDING CONDUCTOR EITHER INSIDE OR OUTSIDE THE CONDUIT. 41. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LANDLORD'S -MECH. /ELECT. DESIGN CRITERIA - ALL CONTRACTORS SHALL OBTAIN A COPY FROM THE LANDLORD'S TENANT COORDINATOR OR MALL OPERATIONS MANAGER AND BECOME FAMILIAR WITH THE REQUIREMENTS CONTAINED THEREIN PRIOR TO BIDDING THE PROJECT. WHERE LANDLORD'S REQUIREMENTS CONFLICT WITH CODES OR ORDINANCES, THE STRICTEST INTERPRETATION SHALL APPLY. PANELBOARDS PANELBOARDS SHALL BE FACTORY ASSEMBLED CIRCUIT BREAKER TYPE BY SQUARE D OR EQUAL THE NUMBER OF POLES, TYPE, VOLTAGE AND AMPERE RATINGS SHALL BE AS INDICATED ON THE DRAWINGS. BUSSING SHALL BE COPPER. CABINETS SHALL BE SURFACE MOUNTED WHERE INDICATED. CABINETS SHALL BE CONSTRUCTED OF GALVANIZED STEEL CONFORMING TO UL AND NEC STANDARDS. NEUTRAL WIRES SHALL BE CONNECTED TO A COMMON NEUTRAL BUS WITH BINDING SCREWS OR LUGS. THE NEUTRAL BUS SHALL BE INSULATED FROM THE CABINET. GROUND WIRES SHALL BE CONNECTED TO A COMMON EQUIPMENT GROUND BUS WITH BINDING SCREWS OR LUGS. THE GROUND BUS SHALL BE BONDED TO THE CABINET. FRONTS OF CABINETS SHALL BE NOT LESS THAN 12 GAUGE STEEL, FASTENED WITH SCREWS IN COUNTERSUNK WASHERS, OR WITH APPROVED CONCEALED SPRING CLAMPS. CABINET FRONTS SHALL HAVE HINGED LOCKABLE DOORS WITH MILLED KEYS (ALL PANELS SHALL BE KEYED AUKE) AND CIRCUIT SCHEDULE HOLDERS WITH CLEAR PLASTIC WINDOWS. PROVIDE TYPE WRITTEN SCHEDULES IN HOLDERS AND SUBMIT COPIES FOR RECORD PURPOSES. DOORS SHALL BE FASTENED TO TRIM WITH FULL LENGTH FLUSH HINGES. PANEL FRONTS SHALL. BE SHOP PAINTED WITH TWO COATS OF PRIMER AND A FINISHED COAT OF GRAY ENAMEL CIRCUIT BREAKERS TO BE INCLUDED AS AN ASSEMBLED PART OF THE PANELBOARD, REFER TO THE PARAGRAPH WHERE THOSE ITEMS ARE SPECIFIED. CIFICUIT BREAKEFIS CIRCUIT BREAKERS SHALL BE BY THE SAME MANUFACTURER THAT FURNISHES THE MAIN SERVICE EQUIPMENT AND PANELBOARDS. BREAKERS SHALL BE MOLDED CASE BOLT -ON TYPE. CLAMP -ON, PUSH -ON, OR PLUG -IN TYPES ARE NOT ACCEPTABLE. REMOVABLE HANDLE TIES AND DUAL, QUAD OR TANDEM BREAKERS ARE NOT ACCEPTABLE. MOUNTING HARDWARE, ACCESSORIES, FACEPLATES AND ENCLOSURES SHALL BE PROVIDED AS NECESSARY FOR THE INTENDED USE. SHORT CIRCUIT INTERRUPTING CAPACITY SHALL BE AS INDICATED ON THE PLANS AND SHALL IN NO CASE BE LESS THAN 10,000 RMS SYMMETRICAL AMPS AT THE APPLIED VOLTAGE. DISCONNECT SWITCHES SWITCHES SHALL BE BY SQUARE D OR EQUAL SWITCHES AND ENCLOSURES SHALL BE GENERAL DUTY, EXTERNALLY OPERATED, QUICK -MAKE, BLADE TYPE, OF NUMBERS OF POLES AND RATING INDICATED OR REQUIRED. SWITCHES SHALL ACCEPT FUSES OF THE RATING AND UL OR NEMA CLASS INDICATED. SHORT CIRCUIT WITHSTAND RATINGS SHALL BE 200,000 RMS SYMMETRICAL AMPS. ENCLOSURES SHALL BE NEMA 1 FOR DRY, INTERIOR LOCATIONS AND NEMA 3R FOR DAMP, WET OR EXTERIOR LOCATIONS. FINISH SHALL BE ANSI 61. COVERS SHALL HAVE A DEFEATABLE INTERLOCK. OPERATING HANDLES SHALL BE PADLOCKABLE. TRANSFORMERS TRANSFORMERS SHALL BE BY SQUARE -D OR EQUAL SIZE AND VOLTAGE AS SHOWN ON PLANS. TRANSFORMERS SHALL BE DRY -TYPE, AIR COOLED, AND DESIGNED FOR 60HZ OPERATION. COMPLY WITH NEMA STANDARD ST20 "DRY -TYPE TRANSFORMERS FOR GENERAL APPLICATIONS ". WINDINGS: TWO WINDING TYPE, 1 COIL PER PHASE IN PRIMARY & SECONDARY. (ALL COPPER WINDINGS), 220'C INSULATION CLASS, 80'C TEMPERATURE RISE TAPS - (6) 2 -1/2% TAPS (2 ABOVE AND 4 BELOW). GENERAL ELECTRICAL NOTES 1. ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND SHALL IMMEDIATELY NOTIFY THE OWNER'S PROJECT MANAGER OF ANY DISCREPANCIES. 2. ALL CONDUITS ARE TO BE CONCEALED IN WALLS OR ABOVE CEILINGS. CONDUITS IN EXPOSED CEILING AREAS SHALL EXIT WALLS AS CLOSE TO ROOF /FLOOR STRUCTURAL DECK AS POSSIBLE. 3. ANY EXISTING MATERIALS OR EQUIPMENT NOT TO BE REUSED MUST BE COMPLETELY REMOVED AND DISPOSED OF PROPERLY THROUGH THE LANDLORD'S DESIGNATED AND APPROVED HAULER. NO EQUIPMENT OR COMPONENTS MAY BE ABANDONED WITHOUT WRITTEN PERMISSION OF THE LANDLORD. 4. ANY PENETRATIONS THROUGH FIRE RATED WALLS NEED TO BE APPROPRIATELY FIRE STOPPED TO RETAIN THE WALL'S RATING. 5. CONTRACTOR SHALL ENSURE LOADS BETWEEN PHASES ON PANEL BOARDS ARE BALANCED WITHIN 10 %. 6. ALL LOW VOLTAGE WIRING IN CEILING PLENUM (INCLUDING TELEPHONE. DATA, ALARM AND TEMP. CONTROL WIRING) SHALL BE UL LISTED TEFLON PLENUM CABLE. T/C T/C RECEPTACLE AND SWITCHED LIGHT PROVIDED BY E.C. TO BE INSTALLED PER N.E.C. 210 -63 & 210 -70c TIMECLOCK FOR STOREFRONT - �- -� RECEPTACLE FOR TELEPHONE. VERIFY EXACT LOCATION NEW 2 #12, 3/4"C PANEL LP REFER TO PANEL SCHEDULE NEW 4 #3, 1-1/4"C 1 #8 GND 1 #8 GND _ TO BLDG STEEL-_ SCALE: NONE PANEL MP REFER TO PANEL SCHEDULE NEW 1 1. ALL WIRE SHALL BE COPPER ONLY, THW, THWN, THHW, OR NEC APPROVED EQUAL OR BETTER. ALL WIRING SHALL BE IN CONDUIT. WIRE AMPACITY BASED ON NEC 110 -14c AND TABLE 310 -16. 2. E.C. SHALL FURNISH ALL NEW ELECTRICAL EQUIP. (PANELS, TRANSFORMER, CONDUITS, WIRE, METERS, SERVICE FEEDERS AND CONDUIT, DISC SWITCHES, CONTACTORS, TIMECLOCKS, ETC) AS REQUIRED, UNLESS NOTED OTHERWISE. NOTE: ALL BREAKERS SHALL BE BOLT -ON, UNLESS OTHERWISE NOTED. • - INDICATES THIS CIRCUIT TO RECIEVE HANDLE LOCK -ON CUP T/C - INDICATES THIS CIRCUIT TO BE CONTROLED BY A TIMECLOCK * - REFER TO ONE -LINE DIAGRAM FOR WIRE SIZE TO THIS EQUIPMENT NOTE: ALL BREAKERS SHALL BE BOLT -ON, UNLESS OTHERWISE NOTED. • - INDICATES THIS CIRCUIT TO RECIEVE HANDLE LOCK -ON CLIP T/C - INDICATES THIS CIRCUIT TO BE CONTROLED BY A TIMECLOCK * - REFER TO ONE -LINE DIAGRAM FOR WIRE SIZE TO THIS EQUIPMENT - - NEW 480V, 30, 30A.S., 15A.F. FOR NEW AIR HAND UNIT 8.6 F.L.A., 5 KW H TER NEW 3 #12, 3/4"C 1 #12 GND NEW � - 4 #3, 1-1/4"C 1 #8 GND 8, 1"C 10 GND i I I NEW 3OKVA, 30 TRANSFORMER LEASE LINE 480/120/208V -L- •EXIST CONDUIT A I I BY LANDLORD NEW 4 #3 1 #8 GND ELECTRICAL ONE -LINE DIAGRAM FIELD VERIFY EXACT METER REQUIREMENTS EXIST 200A.S. WITH NEW 100A.F. SERVICE FROM LANDLORD 277/480V, 30, 4W ELEC. DISTRIBUTION EQUIPMENT 3. ALL ELECTRICAL EQUIPMENT (PANELS, TRANSFORMER, LIGHTS, DEVICES, CONDUIT, WIRE, ETC.) NOT BEING USED SHALL BE REMOVED FROM THE SITE. DO NOT ABANDON IN PLACE. 4. E.C. SHALL FIELD VERIFY ALL EXISTING ELECTRICAL EQUIPMENT. ALSO FIELD VERIFY THAT ANY EXISTING ELEC. EQUIPMENT TO BE REUSED IS OF ADEQUATE SIZE AND CONDITION TO MAINTAIN SAFE OPERATION. IF DISCREPANCIES ARISE CONTACT PROJECT REP. EL iT] ROOF LINE FLOOR LINE RECEIVED JUN - 8 2007 PERMIT CENTL T/C