Loading...
HomeMy WebLinkAboutPermit EL07-650 - WESTFIELD SOUTHCENTER MALL - RACHA THAI AND ASIAN KITCHENRACHA THAI & ASIAN KITCHEN 1150 SOUTHCENTER MALL ELO7-650 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Permit Center Authorized Signature: City►f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 1150 SOUTHCENTER MALL TUKW RACHA THAI & ASIAN KITCHEN 1150 SOUTHCENTER MALL , TUKVVILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA Contact Person: Name: ELIZABETH MONTGOMERY Address: 1405 BOYLSTON AVE , SEATTLE WA Contractor: Name: GREAT WALL ELECTRIC INC Address: 6523 31 AV S , SEATTLE WA Contractor License No: GREATWE954CG DESCRIPTION OF WORK: INSTALL ALL ELECTRIC TO ALL EQUIPMENT AND LIGHTING Value of Electrical: $22,000.00 Fees Collected: Type of Fire Protection: National Electrical Code Edition: Electrical Service provided by: PUGET SOUND ENERGY I hereby certify that I have read and d�ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied t , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit. Signature: - � _� Date: Print Name: 0 L) ELECTRICAL PERMIT doc: EL -4/07 EL07 -650 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 - 322 -4323 Phone: 206 - 898 -9168 Expiration Date: 02/07/2009 ELO7 -650 02/05/2008 08/03/2008 $553.50 2005 Date: O This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 02 -05 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: 1: ** *ELECTRICAL * ** Signature: Print Name: doc: Cond -Elec City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1150 SOUTHCENTER MALL TUKW RACHA THAI & ASIAN KITCHEN LE PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL07 -650 ISSUED 11/02/2007 02/05/2008 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Date: 4 : e EL07 -650 Printed: 02 -05 -2008 ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print ** Site Address: CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www. ci. Tkwila. wa. us Ii Tenant Name: (t hc4+i c+‘ Property Owners Name: Wes +e e PI et 1 I Mailing Address: (k (00 ( W 14 '\ i 't (DV d1 TA 'FIB CONTACT, Who do we contact when your permit isreadyto be issue Name: E ; 2 0144 to ") Mailing Address: ) got, 1 Akre E -Mail Address: 11‘f0 4D Ce;t Cti ^ &1Q , Cam'''■ Company Name: G lea 1 pa e0\4L- Mailing Address:_ S'1"" S H:1Applications\Fortro- Applications On Line14-2007 - Electrical Permit Application.doc bh King Co Assessor's Tax No.: (93 'o 420 -tho iv7 o I I Suite Number: Floor: New Tenant: El. ❑ ..No Gos Ar- City State RCS Zip Day Telephone:(2 " Se3' Seorti / City State Zip Fax Number: wit ' TYl fS City State Zip Contact Person: c )QJ E LEE Day Telephone: 20 C' — 10 E -Mail Address: Fax Number: Contractor Registration Number_ fl -El c.v Expiration Date: Valuation of Project (contractor's bid price): $ ZZ, Scope of Work (please provide detailed information): 1 r 11 f kety ■ (. d'b of I ( e f (.c t W s kAf gn rA Ii5 1��i�S Will service be altered? ❑ Yes No No Adding more than 50 amps? Yes ❑ No Type of Use: Type of work: New ❑ Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: p, Puget Sound Energy ❑ Seattle City Light Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, fumace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change 850.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) Signature: Print Name: 1 C Mailing Address: I Date Application Accepted: ( I H:\ Applications\Fonns- Applications On Line \4 -2007 - Electrical Permit Application.doc bh MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions - $10.00 ea PERMIT APPLICATION ; NOT ` Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Date: (1 / 2/6 Day Telephone: City State Date Application Expires: Staff Initials: Zip Page 2 of 2 Receipt No.: R07 -02412 Initials: WER User ID: 1655 Payee: THAI FOODS INTERNATIONAL TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES L City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049023 Permit Number: EL07 -650 Address: 633 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 11/02/2007 Applicant: RACHA THAI & ASIAN KITCHEN Issue Date: Amount Payment Check 2069 553.50 Account Code Current Pmts 000.322.101.00.0 442.80 000.345.832.00.0 110.70 Total: $553.50 Payment Amount: $553.50 Payment Date: 11/02/2007 04:24 PM Balance: $0.00 doc: Receipt -06 Printed: 11-02 -2007 Project:g Ar 'Tt�f Type of Inspection: j(oO Address: 115b 4' Date Called: Special Instructions: Date Wanted: 71 p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit fLD1-4,50 PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 1'- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 - 3670 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: D (Inspector: „S ri xfplb2 (Date: 07A El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: COMMENTS: 1 144 Folk Ruist Cotoo roe_ btWcar Jouro-46 S/s11+t5 - Nikki rtuke cot_ Ltgbv PA4a, - ,pAzic c 1/4 cor1aosTit5t..6 41415a- Date Called: PA - ,si-ocx/srkrc Special Instructions: a *Pre( Fief pc-Porrtothr A-Nemf4c, oK a 451% cfc ti-r C.1......n P.m. Requester: Project: .•7 KA 4- e- r - (4A - i Type of Inspection: 'iDC> Address: 1193 tiAtt. Date Called: Special Instructions: Date Wanted: -7I'? C.1......n P.m. Requester: Phone No: J Cteri- 6P INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 El Approved per applicable codes. Corrections required prior to approval. 'Inspector: ijd r ate: c ri 6 ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: )10010:%w,lao'414-404iie.%0ouip cl: _ P c/14 T14'4/ / Type of Inspection: 7u A): A N 50 0 5/ 1 /711. POZ{ Date Called: Special Instructions: Date Wanted: Y/01-3 a.m. p.m. Requester: Phone No: PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 (206)431-3670 INSPECTION NO. INSPECTION RECORD Retain a copy with permit -16-0 - 2-6JD OMMENTS: - e(774 /ok 770 - Z 4 per applicable codes. Corrections required prior to approval. Inspectore z inxieimx ././ 'Date: 40 El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Pr West: 7)/t/ id Type of Inspection: -70V3 cr : 11si s2s „iimardi /vex. Date Called: Special Instructions: _ Date Wanted: 4 /// 7 a.m. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1 407 -- 6177 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 OMMEN olL- Was /cI.2 6r---srooik-fj 40eie lInsp pproved per applicable codes. El Corrections required prior to approval. vq & $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Date gh 7/Or Project: C4b9 TM/ Type of Inspection: ...-1 /002 4 144 Address: ? IR) , 301( Pcidlia Date Called: pecial Instructions: Date Wanted: 4 Requester: Phone No: !fa INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION f 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 COMMENTS: r Mus—A/Tc4) Mew 6' e,9c roved per applicable codes. Corrections required prior to approval. linsPern_z__& Date: y El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. r eceipt No.: 'Date: Pr ec / t � : �/ ) Type of Inspection: 70 `/ d r s e A Date Called: Special Instructions: Date Wanted: /Z-' a.m-. p.m Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION g 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 MMENTS: - 1A/-/_/1 Itnspe ved per applicable codes. ❑ Corrections required prior to approval. e i rmd7/"/N4/T I El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: November 26, 2007 Elizabeth Montgomery 1405 Boylston Av Seattle WA 98122 RE: CORRECTION LETTER #1 Electrical Permit Application Number EL07 -650 Racha Thai and Asian Kitchen —1150 Southcenter Mall Dear Ms. Montgomery, This letter is to inform you of corrections that must be addressed before your electrical permit can be approved. All correction requests from the Building Department must be addressed and reflected on your drawings. Building Department: Bill Buterbaugh, at 206 973 -4758, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that three (3) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted throueh the mail or by a messenger service. If you have any questions, please contact me at (206) 433 -7165. Sincerely, encl ifer Marshall it Technician xc: File No. EL07 -650 City of Tukwila P:\Pemrit CentMCorrection Letters\2007\EL07 -650 Correction Ltr #1.DOC jem Steven M Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206 - 431 -3665 Date: November 21,2007 Project Name: Racha Thai and Asian Kitchen Permit #: EL07 -650 Plan Reviewer: Bill Buterbaugh Building Division Review Memo 1. Provide complete load calculations for each panel and feeder per NEC Article 220. 2. Provide complete one line drawing, including grounding. 3. Transformer size? Plans indicate 12.5KVA. Verify transformer loads. 4. Provide Lighting plan and complete luminaire schedule. 5. Egress path requires 1 foot candle at floor along the entire pathway and egress discharge area. ACTIVITY NUMBER: EL07 -650 DATE: 12 -31 -07 PROJECT NAME: RACHA THAI & ASIAN KITCHEN SITE ADDRESS: 1150 SOUTHCENTER MALL _ Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued DEPART NTS: Op, 1 I- I • mg i sion Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: TUES/THURS ROUTING: Please Route APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2-28-02 'PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete Structural Review Required Planning Division ❑ Permit Coordinator DUE DATE: 01 -03 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required C REVIEWER'S INITIALS: DATE: DUE DATE: 01 -24 -08 Approved ❑ Approved with Conditions d Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: EL07 -650 DATE: 11 -02 -07 PROJECT NAME: RACHA THAI & ASIAN KITCHEN III SITE ADDRESS: SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Building Division Public Works Complete TUES/THURS ROUTING: Please Route PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP fit El APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28-02 Fire Prevention DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Structural Review Required Planning Division Structural ❑ Permit Coordinator ❑ DUE DATE: 11 -6-07 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 12 -4 -07 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ri Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: 1.11Z/40e Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: n Date: 1Z 12-r f City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: EL07 -650 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Steven M. Mullet, Mayor Steve Lancaster, Director Project Name: Racha Thai & Asian Kitchen Project Address: 1150 Southcenter Mall / Contact Person: E 1 t 2-0,1- J J" t/ Dlyte4/ 0 Phone Number: 2-0 '" / Summary of Revision: / RE, tJ i y cc_ s vett"Q S tern ift e, Sheet Number(s): L / Leo) , �3 C 7 "Cloud" or highlight all areas of revision including date of Ievision Received at the City of Tukwila Permit Center by: Zr Entered in Permits Plus on J2 /3 //d 7 a�pplications\fotms- applications on line\revision submittal Created: 8 -13 -2004 Revised: RECEIVED crty •F TUKWILA IDEC 31 20011 PERMIT CENT »:' Business Owner Information Name Role Effective Date Expiration Date LEE, YOUNG AGENT 02/07/2005 LEE, YOUNG PRESIDENT 02/07/2005 KEHLE, RON AGENT 03/07/2005 03/07/2005 Nowe Look Up a Contractor, Electric "n or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License Licensee Name Licensee Type UBI Ind. Ins. Account Id Business Type Address 1 Address 2 City County State Zip Phone Status Specialty 1 Specialty 2 Effective Date Expiration Date Suspend Date Separation Date Parent Company Previous License Next License Associated License GREATWE954CG GREAT WALL ELECTRIC INC ELECTRICAL CONTRACTOR 602434633 CORPORATION 6523 31ST AVE S SEATTLE KING WA 98108 2068989168 ACTIVE GENERAL UNUSED 2/7/2005 2/7/2009 GREATWE977C7 LEE* *YK973CR Electrical Administrator Information License Name Status LEE* *YK973CR LEE, YOUNG KONG ACTIVE Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= GREATWE954CG 02/05/2008 �-mNG FIXTURE SCI-HEDILE CE{LING PLAN SYMBOLS SYMBOL Np FIXTURE QTY. QTY. MMANACNpRE WATTS LAMP SUPPLIER P1 PENDANT LIGHT 28 KISCHLER 25 INCANDESCENT WI WAIL SCONCE 17 HUBBERIFORGE 25 INCANDESCENT EPI EXTERIOR POLE LIGHT 8 KISCHLER 40 HALOGEN I Fl FLUORESCENT FIXTURE (KITCHEN) 16 AMERICAN FLUORESCENT 32X2 2 PIN FLUORESCENT CEILING MOUNT 4 KI$ HLER 40X4 INCANDESCENT ) CHANDELIER ' ©` El EMERGENCY UG 11NG 5 BEST LIGHTING 5 BATTERY BACH L F3 BATHROOM LIGHTING 2 NUTONE 75 INCANDESCENT NT COMBO w1 WI WALL MT LIGHT 2 60 HALOGEN 1 1F1 TRACK FIXTURE 40W 1 TF2 TRACK FIXTURE 40W TI TRACK UGHT(8'KITCHEN) 7 CAL LIGHTING 2400W HALOGEN T2 TRACK LIGHT 6' 3 CAL LIGHTING 2400W HALOGEN !'A RI RECF551m WCM OE SG NT tit 1T 25 HALO 40W wCAP Ni' `YS R2 RECESSED INC 1N SCENT LIGHT 2 HALO 60W OLCAMOESCEIIT CG R3 RECESSED I1CA111 SCENT 3 UCiiT 30 HALO 25W WCAHDESCFNT IC1 C7 EXTERIOR L.OW TALE SPOT 7 PW411T 20W $ ON ICANOEST el C2 C2 EXTERIOR LOW VCLTAL SPOT 3 PW411T BOW �ICAt IT symbol tiara sYmbal description SINGLE POLE SWITCH ®SC FOR SIGN C C ONN IRCUIT ECIIDNB ABOVE Y TB CEUNG �UWT I . DIMMER SWITCH 0 CEUNG MOUNT SPEAKER F/ MUZAK SYS. AIR JUNCTION BOX 3 AIR DIFFUSER n DOOR ALL 11 NEW G WB CEH.WG li HT: 11' AF.F. D A Ci STOREFRONT SIGNAGE MUST BE ON SEPARATE CIRCUIT AND ON 7 DAY TIME CLOCK SET TO MALL'S OPERATINGHOURS 2r 1� EXHAUST HOOD BY OTHER CLASS I HOOD HT: 10' MZEUI w AWE i i i iii ii 1. ; I A UI ihIIIUI 3 •:: � � 1111,F1 —411 1 I 17 _I x A e� ■ s.. x 7 ` - ar..�r�: rrrrr�w�� �ww% T 1 1,11411) I � v J� / f \ q fOi 'tI ©J 09 WIENKNOMIRMSIMM A-- 2, --4, -6 FIELD VERIFIED LOCATION A- 8,-- 10, -12 24 -O' EXHAUST HMO BY OTHER CLASS 1 H000 \ " 4ow(Tw) REFLECTED CEILING PLAN NO ; J'/ZoW is /9 veR/9 66 / Four C ) b Lt /U I/nt /it)/9` 7/ o4) /97 f G-OO✓ / -o Q ZN7 &.4665 0/97: /G2/9 V ,3rvi) S \v Alsc-// ALL EXTERIOR LIGHTING MUST BE ON SEPARATE CIRCUIT AND ON 7 DAY TIME CLOCK SET TO WESTFIELD'S MALI- AND WASHINGTON TUKWILA REQUIREMENTS. 3116° =1'-O' WED FOR CODE COMPLIANCE NFPA 70 JAN 10 2OB City Dfi Tukwila - g DNC D SIGN TENANT SIGN LIGHTING CONTROL NOTES: 1. PURPOSE IS TO PROVIDE SIMULTANEOUS CONTROL OF ALL TENANT SIGNS. 2 CONDUIT, WIRING, AND POWS? TO SIGN SHALL BE PROVIDED BY TENANT. 3. CONTROL J-BOX AND CONTROL WIRING FROM CENTRAL TIMER TO J -BOX SHALL BE PROVIDED BY CONTRACTOR. 4. RELAY, CONDUIT, AND CONTROL WIRING TO SIGN CONTROL J-BOX SHALL BE PROVIDED BY TENANT. 5. FRONT J -BOX AT SIGN AND CONDUITT STUB - IN INTO TENANT SPACE SHALL BE PROVIDED BY GENERAL CONTRACTOR 6. WIRING AND FINAL CONNECTION TO SIGN SHALL BE BY TENANT SIGN POWER CONDUIT AND WIRING BY TENANT 1-1 T-.1 -BOX FOR SIGN I POWER AND STUB THROUGH BY GENERAL CONTRACTOR RELAY_ ASCO 1255- 16S -30-C 3P. 30A WITH NEMA 1 ENCLS (BY TENANT) 'TENANT PANEL EP -D TENANT SIGN CONTROL DETAIL SIGN CONTROL J -BOX, CONDUIT AND WIRING BY GENERAL CONTRACTOR CONDUIT AND CONTROL WIRING BY TENANT D E S I G N S T U D I O PLANING AND DESKIN 1405 Bai STON AVE. &6A111. WA 98122 TB— 20$322A3323 EilAILIFORCATCHSTLUO.COM WwIW.CATCHSTUDIO.COM ENONEER J0141 BLACKLAW 7224 JAlaES R®. SW ROCEESTEi WA EXPIRES KITC1-EN MICA awl ST AVE. SOUTH SEATTLE ,WA 206.6821472 FAX 206.6822367 R THAI :x ASIAN KITCrHEN HERM DM* CATCH DESECN STUDIO SCALE: AS NOTED Location (fioortroom no.) T — Fixture Description Number of Fixtures Area In 11 Watts/ Fixture Watts Proposed ,p './1h1I Ac'i -e5A- 1 - t 2-- q r 1'-5 .1 I t13 t LA 7 ,7 1 x I 7 a — b4 d�t A 2 ~ro/617.6 Total Allowed Watts i2 4'..47 LV4c. V if- le.."' 'V 7 4+4,4;41,4 Outdoor Areas 02 WM Location (floor /room no.) Occupanty Description Avowed Watts per ft " Area In 11 llowed x Area Covered Parking (standard paint) ,p './1h1I Ac'i -e5A- 1 - t 2-- •L}' -[; 4*1j 2 7 C� 'Covered Parting (reflective paint) 'fir,GP- . -" * a l -Zo x I 7 a — A Xi z 2 ~ro/617.6 Total Allowed Watts '51 x20 • .• From Table 15-1 (over) - document all exceptions on form LTG-LPA Location Description Allowed Watts per if or per If Area in f (or If for perimeter) Allowed Watts x ft (or x tf) Covered Parking (standard paint) 0.2 WM2 - 'Covered Parting (reflective paint) 0.3 W/ft Open Parking 0.2 W /ft Outdoor Areas 02 WM Bldg. (by facade) 0.25 WM Bldg. (by perim) 7.5 W/if Note: for building exterior, choose either the facade area or the perimeter method, but nbt both) Total Allowed Watts _ Location Fixture Description J Number of Fixtures Watts/ Fixture Watts , Proposed Ex Total Proposed Watts may not exceed Total Allowed Watts for Exterior Total Proposed Watts 11 H JL IL T. p J EXISTING PARAPET BY MALL w Q 0 J rL A 0 O a 0 r N P1 0 P1 A 0) P1 0 0 F #1 0 N 0 Q 0 LOCATED® WITHIN 25' OF HVAC 1 ROOF LEVEL EL. +46.85' ALL EQUIPMENT CAN NOT EXCEED THE PARAPET HEIGHT (8'UPFROM ROOF LEVEL) HVAC 1 BY orders C) 1 1 1st FLOOR ROOF LINE 4 =10 HVAC 2 BY OT}1ERs HVAC #1 HVAC #2 HVAC ON THE ROOF FUSE DISCONNECT SWITCH 3 PHASE. WP 60A 4- #6 -3/4 "C > EPA -1,3,5 FUSE DISCONNECT SWITCH 3 PHASE. WP 60A -- #6 -3/4 "C EPA 7,9,11 1 NORTH SITE / ROOF PLAN SCALE 3J16° = 1'-0° 11 sE_ RCR ROOM NO. CAVITY FACTOR = 5 (L +W) = ( qc hcc .S brc ° 3 RCR 5- ( hfc FCR % pcc MAINTENANCE FACTOR MV F I LAMP A-0 NO. LAMPS = FC X AREA FIXTURE MFR. CAT. NO. ie j LW MTG. HGT. A.F.F 0 'WORK PLANE CCR 4c' % CEILING REFLECTANCE % WALL REFLECTANCE rLf % FLOOR .REFLECTANCE % pcc % pcc LLD LUMENS X CU X MF SCH. TYPE INSTALLED FC = BY G . LGE Form 120 (10/75) 2001 Washington State Nonresidential Energy Code Cart ce Forms LIGHTING CALCULATTIORSHEET ZONAL CAVITY METHOD I. LENGTH 'X . 7 WIDTH = . % pw 11A0.7 1 CHECKED 7 - 2001 Washington State Nonresidential Energy. Code Compliance Form Maximum Allowed Lighting'Wattage (Interior Total ljra' posed Watts may not exceed Total Avowed Watts for In Maximum Allowed Li Watta (Exteri or LDD LUMENS DATE ° JOB NO. USE AREA 111 FC t ill 1 n 'WW1) EFFECTIVE CU CORRECTION I MF SH. NO. °/a pcc % pw % pfc Notes: - 1. Use mks fisted maximum input wattage. For Hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used 2. Include exit fights unless less than 5 watts per fixture_ Prolapsed Lit Mint Wattage (ltterior) 3. List all fixtures. For exempt lighting, not exception and leave Watts/Fixture btank. Use mtgr fisted maximum Input wattage. For textures with hard -wired ballasts only, Proposed Li tin Wattage (E,deri used. or ) the default table in the NREC Technical Reference Manual may also be use ELO7 65-0 REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC JAN i ,) 2000 Oral P City Of Tukwila L BUILDINDi'LiSiQJL LUMENS X CU X: MF X LAMPS = X . J �' l A REA > t tit g Sumrna June 2001- IUM Project Info Project Address Applicant Name: Applicant Address: Applicant Phone: Date For Building Department Use Project Desadpl ion 0 New BuiWslg ❑ Addition ❑ Alteration ❑ Plains Included Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Prescriptive ® Lighting Power Allowance 0 SYstems Analysis (See Qualification Cherdcfist (over). Indicate Prescriptive & IPA spaces dearly on plans.) Alteration Exceptions (check appropriate box) ❑ No changes are being made to the righting ❑ Less than 60% of the fixtures are new, and Malted Lighting wattage is not being increased EcE.nEr DEC 312007 PERMIT SIT CENdyL.h @PriFIEDO D E S I G N S T U D I O PL.AMING AND NTERIOR DESIGN 1405 BOYLSTON AVE BATTLE WA 98122 TEL 206222A323 E- MALtfO.CATCHS1 CIOCOM WWwCATCHSIL 01000M JOHN BLACKLAW 7224 JANES P SW ROCHES1ER WA 98579 MET TTTLE: ON CIEgCEI) FLE KITCI- •DESIGN BARGREEN ELLEN 36271 ST AVE SOU1 H SKITTLE ,WA 98134 PHONE 206.682.1472 FAX 206:61322357 PROJECT 7TTLE RA THAI & ASIAN KITCHEN vwrv POCFr 11 C oin ::; WESTF .D MAIL CIiEWLA, WA) SITE ROOF PLAN PRIMA DEOGN CATCH DESK STUDIO DRAWN THOMAS U DATE 12/28/07 SCALE AS NO1E ) E3 SUPPLIER Latino DESCRIPTION MANUFACTURER MODEL NUMBER ELECTRICAL ' PLUMBING GAS NOTES MCI SdWV dH VOLTS 1 (PHASE 'NNOO IOH 0m03 WASTE ilNO� ni8 c ; w c, W <, w moo v) l 1 300 6000 I 1 BACK BAR REFRIGERATOR TRUE 113B- 24GAL -60 I 7.0 120 1 DCO 1 HVAC # 1 6000 3 1 I NEMA 5 -15P 2 I- 6 1500 1 1 DRAFT BEER COOLER TRUE TDD -4 2000 8.5 120 1 DCO 1 8 1/2" 600 M 1 INDIRECT DRAIN, NEMA 5-15P 3 III.- -II 6000 7 I 1 ' BACK BAR REFRIGERATER TRUE TBB- 24GAL -60 M 7.0 120 1 DCO 1 , I I �, 1 12 1500 NEMA 5 -15P 4 H 800 3 TV (FLAT SCREEN LARGE) 14 1500 WALKIN - COOLER K H , I 1500 13 16 1500 ( #100) K 5 M EF- 1(3HP) 1500 20 EXTRA OUTLET FOR SMALL APPLIANCES , I #5 18 1000 WALKIN - FREEZER K M K 1500 17 M 6 . 20 1000 1 BACK BAR CUSTOM 1 1500 19 1 11 #7 22 400 WALKIN COOLER BLOWER /TUTS L M 7 I►, 4 1500 21 1 1 BLENDER STATION GLASTENDER BSB -18 1 15 120 1 JBOX 1 2" 1/2" 1-1/2' II 11 INDIRECT DRAIN, NEMA 5-15R 8 ►" 23 1 1 : HAND SINK UNIT GLASTENDER HSB -12 -D 1 200 25 ii " 1/2 1/2" 1 -172 26 1500 1 DIRECT DRAIN 9 ! `l 200 1 1 LIQUOR STEPS GLASTENDER LOA -18D 1119 30 27 28 50 #44 (ON ROOF) 27 29 1 „ 30 32 1 CUSTOM TABLE 300 1 M 4D 31 „ " #24 (WIRE #10) 34 31 1 300 1 M 4 PHONE /FAX i 1 2000 36 3500 33 34 300 #45 M 1 �' 12 1►° 4. K 1 1 COCKTAIL STATION 1 GLASTENDER CBA- 36LCP10 1 36 36 3500 > #46 (WIRE #10) 37 1 I 1-1/2" 40 1 INDIRECT DRAIN 13 1►'.► 37 1 1 GLASS CHILLER J TRUE T-50-GC 1 7.6 120 1 DCO #24 / 3500 39 40 41 14 110- -. ! M 1 1 HAND SINK UNIT I GLASTENDER HSB -18 K #57 3500 41 42 1/2" 1/2 1 -112 11 DIRECT DRAIN 15 ► 1 1 DRAIN BOARD 1 GLASTENDER DBA -36 1-1/2" 1 INDIRECT DRAIN 16 1• .4 1 38 CUSTOM BAR 1 1 " , I 1 39 17 ': 1 5 CALCULATOR 1 1 41 42 1 18 i 1 11 PHONE LINE JACK 1 19 I.*- -4 1 BAR ASSEMBLY W /GLASS WASHER 1 GLASTENDER CS -84CCW 20.0 208 1 JBOX 1/T 1/2 1-1/T ! INDIRECT DRAIN 20 11 0.-4 SERVICE STATION CABINET 1 21 ►-i 1 1 ' ICE CREAM FREEZERS 2.5 120 1 DCO 1 NEMA 5 -15P 22 10' 1 1 I DROP -IN ICE BIN DELFIELD 305 1° 1 INDIRECT DRAIN ®!io"11 111311* ® 26 27 1111 WATER FILLER 1 T &S B -1230 IN 33.4 15 8.6 208 208 120 120 JBOX PR DCO DCO NEM 1 • MI -4 HOT WATER DISPENSER 1 BLOOMFIELD 1225 1111111 1111 INDIRECT WASTE 1 1 41 ESPRESSO MACHINE 1 MICHAELO ESPRESSO COFFEE BREWER I BLOOMFIELD 9102A UNDERCOUNTER REFRIGERATOR 1 TRUE TUC -48 11 ► -11.11 i® NEMA 5 -15P 28 0.-"4 WALL SHELVING I 29 I I 1 UNDERCOUNTER REFRIGERATOR I TRUE TUC -27 1 8.8 120 1 DCO 1 30 1 1 SODA /ICE DISPENSER I CORNELIUS ENDURO 150 3 115 1 31 I® 1 1 DISPLAY CASE TCGR --50 15.2 120 1 DCO 1 NEMA 5 -20P 32 I 1 7 1TRUE VACUUM 1 1 33 i 2 AIR FRESHENER MACHINE I 34 114 1 CABINET 1 CUSTOM 1 35 =- 1 1 SODA GUN WUNDER BAR SODAGUN 1 1 36 1 1 1 DROP -IN ICE & WATER UNIT DELFIELD 248 240 1 1 1/2" 1° I INDIRECT DRAIN ®4.1 38 39 40 1® NM ' Nd HEAT LAMP 1 GLOW-RAY GRAH -66 OP. - 41 WALL MOUNT HAND SINK /W FAUCET ADVANCE DI -1 -10 1/2" 1/2 " 1 -1/2" 1 I DIRECT DRAIN 110-41 HEAT LAMP GLOW -RAY GRAH-84 i 240 1 1 1 1 36" GAS RANGE 1 MONTAGUE 136-5 i 3/4" 220,000 41 1. 1 1 TABLE SPACER 1 TRS SPACER i 42 1'l 1 1 GAS CHAR BROILER MONTAGUE UFSC -36R 1 3/4" 120,000 1 43 1►u 1 1 FRYER PITCO S6145 1 3/4" 110,000 1 44 '► 1 1 24 GRIDDLE I 1 0.2 120 1 DCO 1 3 4 - 60 000 1 -I 45 N1 3 I NETWORK 1 I_ME ME 46 1 1 1 : HOT WATER DISPENSER BLOOMFIELD 8708 120 1 1 47 0-'4 1 1 GAS STOCK POT RANGE IMPERIAL ISPA -18 -2 1 180,000 1 48 ►;- 1 1 ;TABLE SPACER TRS SPACER 1 I 49 ).::4 1 1 GAS PASTA COOKER 1ELECTROLUX 200372 1 7.7 208 3 JBOX 1/T 53,000 1 50 I 1 TABLE SPACER 1TRS SPACER 1 1 2 RADIO 1 MONTAGUE 136 -5 I 1 1 51 52 I COMPUTER /MONITOR /PRINTER SYSTEM 1 I 53 I 1 SPARE NUMBER 54 I. 1 TRS HOOD 1 MUA FAN REZNOR GAS HEA I ER 1 TRS HOOD III13.4 1 REFRIGERATED PREP TABLE 1 TRUE TPP -67 CO a Q0� W s.F Q Q m 0 W C4 W C4 p Q ffi L a i fa Z cx r r f+7 8.6 115 208 120 -mo JBOX ELECTRICAL FOR LIGHTS ®'I IN. ` - II =_I DCO 11 500,000 VERIFY GAS INLET SIZE 56 . - ii DCO NEMA 5-15P 57 I i 6 MICRO WAVE 58 ! ■■ 1 1 ; F1RE SUPPRESSION I R &T FIRESUPP 59 I I ;SPARE NUMBER 1 60 111.- ■, 2 REFRIGERATED PREP TABLE 1 TRUE TPP -93 9.7 120 1 DCO NEMA 5 -15P 61 ,r.--4 ; HAND SINK 1 TRS SPACER 1 -1/2 DIRECT DRAIN 62 '► 1 FAUCET 1 T &S B -0326 1/2 1/2 1 63 i■--4 1 ELECTRIC STEAM TABLE 1 SUPREME SW -4E- 208 -DR -MT 15,8 208 SCO 1" 1 1 INDIRECT WASTE, NEMA L6 -30P 64 I SPARE NUMBER I 1 65 SPARE NUMBER 1 1 66 ►_ 67 :` SERVER STATION CUSTOM I 1 1 CUSTOMER PAGER 68 1 4 ■■ M SPARE NUMBER f m HAND SINK TRS SPACER 1 -1/2 DIRECT DRAIN 69 !1 10.--41 FAUCET 1 T &S B -0326 1/2" 1 /2" 70 I Bk.--4 71 !t�1 1 UNDERCOUNTER REFRIGERATOR 1 TRUE TUC -48 8.6 120 1 DCO NEMA 5 -15P 72 1 TABLE SPACER 1TRS SPACER 73 i 2 FLOOR LAMP 74 io411 1 GAS WOK RANGE 3/4 137,000 75 I -:4 1 SPACE TABLE TRS SPACER 76 1 GAS FRYER PITCO 1-- SF- SG14RSSTC -S 1 3/4 122,000 77 ► .4 SPARE NUMBER I 1 78 10.-4 M Mil 1 1 r\ -Tr N (C) GAS CONVECTION OVEN HOOD MUA FAN REZNOR GAS HEATER BLODGETT ZEPHAIRE G DBL TRS HOOD TRS H000 2)6.1 13.4 120 208 208 1 DCO JBOX 13T4 (2)120,000 ELECTRICAL FOR LIGHTS 79 il1.- DCO 1/ ' 500,000 VERIFY GAS INLET SIZE 79.1 II ■■!1111111. , F1RE SUPPRESSION (SUPPLIED BY OTHERS) R &T FIRESUPP 1111 , 1 80 il>• -4I DROP-IN HAND SINK ADVANCE DI -1--10 1-1/2 i DIRECT DRAIN 81 II ►! ' FAUCET 1 T &S B -1141 ■■� 1/2" 1/2° 82 ![►r!�� 60" WORK TABLE I ADVANCE MS -245 LIGHTING DECORATION HOLIDAY LIGHTS 1 i . 83 110.---41 84 ;MEN RICE COOKER 1 TOWN 57155 3/4 34,600 85 ;►;.4 86 ►.l E RICE WARMER TOWN 56918 8.0 120 1 DCO 87 1. -- I TWO COMPARTMENT SINK ADVANCE 9-2-36-24L 1-1/2" 1 INDIRECT DRAIN 88 b. -4. i FAUCET T &S B -0231 1 1/2 1 89 I4 1 E 120° WORK TABLE ADVANCE SS -3010 1 90 ►' -* 1 WALL SHELF 1TRS SHELF 91 0.- 41 1 1 ONE COMPARTMENT SINK ADVANCE 9 -1 -24 1 -1/2 I INDIRECT DRAIN 92 0-4 FAUCET T &S B -0231 1/2" 1/T 1 93 1 MIXER TABLE 94 i 1 20 QUART MIXER 1 9.4 1/2 120 1 DCO 1 NEMA 5-15P 95 ' SPARE NUMBER 1 96 i® 1 96" WORK TABLE AADVANCE SS -308 1 97 11 ' 4I WALL MOUNT SHELF 1 ADVANCE WS -12 -48 IMI ICE MAKER 1 MANITOWOC SD-1692N WALK-IN FREEZER 1 NOR -LAKE KLF7768 -C 1 19.4 IIIIII 208 208 98 1► -411111 JBOX 1 J2" 1" 1 INDIRECT DRAIN JBOX 99 -: 4 100 ' ►° ■� 1 WALK -IN COOLER NOR -LAKE KLB74814 -C 208 1 JBOX GLASS DOORS NOR -LAKE DOORS 1 101 ' Jr-4 102 -. ■■ C 60" WORK TABLE 1 ADVANCE MS -305 1 103 1® 72 WORK TABLE ADVANCE MS -306 104 I 1 SPARE NUMBER 105 1 SPARE NUMBER I 1 106 lo--41 i 1 1 DISHTABLE ADVANCE DTS- U30 -96R I 1-1/2 1 INDIRECT DRAIN 107 ! N: t 1 PRE -RINSE FAUCET 1 T &S 13- 0133 -B 11/2" 1/2' 1 108 I® 1 1 DISHWASHER I AUTO CHLOR (A4) 1 2" WASTE 109 ►:- 1 3 COMPARTMENT SINK 1 !INDIRECT 110 ►'` ! 1 1 • DISHWASHER CLASS II HOOD 111 ! 1 1 , RICE COOKER CLASS II HOOD 112 1 0.- -4 1 2 WALL-MOUNTED SHELF 1 ADVANCE WS -15 -48 1 113 110 2 WALL - MOUNTED SHELF 1 ADVANCE WS -15 -72 114 I►- 1 2 MAIN ENTRANCE SIGNAGE TRS HOOD I 7,0 120 1 JBOX 115 ' i 1 MALL ENTRANCE SIGNAGE I 116 ice► 117 1► 4' 1 I r r STORAGE SHELVING METRO SHELVING 1 EMPLOYEE LOCKERS ( WIN -HOLT LOCKER 1 118 1® 1 MOP SINK 1 ADVANCE 9- OP -20 -X I 2" DIRECT DRAIN 119 I ► =r 11 SERVICE SINK FAUCET 1 T &S B -0665 -BSTR 1 1/T 1 /L" 120 i IP -4 1 MOP SINK i ADVANCE 9- 0P -20 -X 1 1 2" DIRECT DRAIN 121 10.-"-4 1 SERVICE SINK FAUCET 1 T &S B- 0665 -BSTR 1 11 /21 /2" 122 I1• ► 20 POS NEEDS 3 (OUTLETS EACH ONE) I 1 1 123 I :1I 1 2 HOT WATER HEATER (120G) 1 A.OSMITH (DSE -120) 36 43.3 3 1 122K BTU PANEL SCHEDULE "EP-A" VOLTAGE 2120/208V 3 PHASE, 41WRE....... ■ 208V., 3 PHASE, 3 WIRE ❑ 277/480V., 3 PHASE, 41ERE........ ❑ 480V., 3PHASE, 3 WIRE MOUNTING: ❑ FLUSH Pi MAIN: ❑ LUGS ONLY AMP. 'TOP n MAIN BREAKER 200 AMP. ■ BOTTOM NEUTRAL: ❑ 50% DO= COVER: ❑ DOOR WITH LOCK ❑ DOOR vniouT LOCK ALL BREAKERS 20 AMP. 1 POLE UNLESS NOTED OTHERWISE U/L LISTED BREAKER INTERRUPTING CAPACITY : 12000 RMS S. IMPS. CONNECTED LOAD: PHASE A 21100 W., PHASE B: 19900 W., PHASE C., 19400 W., TOTAL 60600 WATTS LOCATION LOAD NO. 70 ABC NO. LOAD LOCATION (168A) 2 1500 900 M H 300 6000 1 ( �, 20 4 1500 MF -1 (3HP) 3 H HVAC # 1 6000 3 1 11 1 6 1500 900 M H 2000 6000 5 70 1 II " 1 8 1500 600 M H 1800 6000 7 10 1500 MF -2 (3HP) M H HVAC # 2 6000 9 1 1 , I I �, 1 12 1500 OUTSIDE LITS M H 800 6000 11 14 1500 WALKIN - COOLER K H , I 1500 13 16 1500 ( #100) K M EF- 1(3HP) 1500 15 ( , I #5 18 1000 WALKIN - FREEZER K M K 1500 17 M 20 1000 (#99) K M M 1500 19 1 11 #7 22 400 WALKIN COOLER BLOWER /TUTS L M EF- 2(3HP) 1500 21 I „ #1i 24 400 WALKIN FREEZER BLOWER /UTS L M K 1500 23 II 11 #13 26 23 24 1500 M SUP.SYSTEM(#80) (#58) 200 25 ii " #17 28 25 26 1500 M RECEPTACL.E@FIVAC 1 & HVAC 2 200 27 " „ 1119 30 27 28 50 #44 (ON ROOF) 27 29 , I „ 30 32 29 30 300 #45 M 4D 31 „ " #24 (WIRE #10) 34 31 32 300 #45 M 1 • 33 i 11 2000 36 3500 33 34 300 #45 M 35 �' „ K 38 K 3500 35 36 36 3500 > #46 (WIRE #10) 37 1 I 1 40 _ K 3500 37 37 3500 39 K 11 III , 42 #24 / 3500 39 40 41 #4 M 1 ii K #57 3500 41 42 PANEL SCHEDULE "EP-B" VOLTAGE 2 120/208V., 3 PHASE, 4WIRE....._. El 208V.. 3 PHASE, 3 WIRE ❑ 277/480V., 3 PHASE, ORE.-. ❑ 480V., 3PHASE, 3 WIRE MOUNTING: FLUSH 2 MAIN: ❑ LUGS ONLY AMP. E ✓TOP ❑ MAIN BREAKER 200 AMP. ❑ BOTTOM NEUTRAL ❑ 50% Er100% COVER: El DOOR WITH LOCI( ❑ DOOR WITHOUT LOCK ALL BREAKERS 20 AMP. 1 POLE UNLESS NOTED OTHERWISE U/L USIED BREAKER INTERRUPTING CAPACITY : 12000 RMS SYN. AMPS. CONNECTED LOAD: PHASE A 19950 W., PHASE B: 20200 W., PHASE C., 21750 W., TOTAL 61900 WATTS LOCATION LOAD NO. 20 ABC NO. LOAD LOCATION (172A) K EQUIP. TYP. #1 900 1 2 300 #21 K ( 11 20 K #2 1050 3 4 2000 #25 K 1 ii 1 K #3 900 5 fi 2000 1000 K , I M #4 600 7 8 1800 #26 K 720 " 8 M #5 800 9 10 1100 #27 K I' OUTSIDE LITS M #5 800 11 12 1100 #29 K „ , I M #5 1600 13 14 400 #30 K I M #5 1400 15 16 1850 #31 K 20 „ M #5 1200 17 18 200 #32 M 1 II 15 K #7 1800 19 20 50 #33 M 19 " ii M #1i 2D0 21 22 2000 #36 K 21 „ II K #13 1000 23 24 1500 #37 L 23 1I ii M #17 200 25 26 1500 #34 L 30 3 1 ° 1 " K 1119 2250 27 28 50 #44 K 27 I' , I K 30 2250 29 30 300 #45 M 4D „ „ K #24 (WIRE #10) 3500 31 32 300 #45 M 1 • ii i K 2000 #98 3500 33 34 300 #45 M 40 �' K #24 K 3500 35 36 36 3500 > #46 (WIRE #10) K 1 II 1 K _ K 3500 37 37 3500 )• K 40 III , 32 #24 / 3500 39 40 200 #4 M 1 ii K #57 3500 41 42 11 35 36 PANEL SCHEDULE "EP-C" VOLTAGE: 1 120/208V., 3 PHASE, 4WIRE-..._ -. • 208V., 3 PHASE, 3 WIRE I=1277/480V.. 3 PHASE, 4WIRE........ ❑ 480V., 3PHASE, 3 WIRE MOUNTING: Ill FT11SH 2 MAIN: ❑ LUGS ONLY AMP. 'TOP ❑ MAIN BREAKER 200 AMP. • BOTTOM NEUTRAL: ❑ 50% P100% COVED ■ DOOR WITH LOCK ❑ DOOR WITHOUT LOCK ALL BREAKERS 20 AMP. 1 POLE UNLESS NOTED OTHERWISE U/L LISTED BREAKER INTERRUPTING CAPACITY : 12000 RMS SYM. AMPS. CONNECTED LOA): PHASE A 14800 W., PHASE B: 14500 W, PHASE C., 15600 W., TOTAL 44900 WATTS LOCATION LOAD NO. 20 ABC NO. LOAD LOCATION (126A) 2 1500 #57 K K 400 1000 1 ( " 4 1500 # K K #49 1000 3 1 I 6 1200 #60 K K 725 1000 5 11 8 1200 #60 K K #85 1250 7 720 " 8 10 1700 #63 K M #52( #1) 300 9 " OUTSIDE LITS 12 1700 10 K M #52( #2) 300 11 „ , I 14 200 #67 M M #52(#3) 300 13 II 16 1100 #71 K M #52(0) 300 15 20 II 18 400 #73 L M " 1700 17 1 ,i 15 20 400 #78 K M 1700 19 1 ii ?X41.IT @PREP AREA & KITCHEN UTE 22 400 #78 K M 1700 21 20 II „ 24 1000 184 L M 20 1700 23 1 ii 26 1750 #85 K M #79.1 1700 25 1 " 28 200 #51 M M „ 1700 27 SIGNAGE #115 , I 23 30 500 # K K #56 1100 29 „ „ 3 1 32 1200 04 K K #56 1100 31 i 34 34 2000 #98 K K #56 • 1100 33 II I 2000 K K #57 1500 35 , I 30 38 K #57 1500 37 '1 40 31 32 K #57 1500 39 , I " 42 K #57 1500 41 11 35 PANEL SCHEDULE "EP-D" VOLTAGE: 020/208V., 3 PHASE, 41WRE....... ❑ 208V., 3 PHASE, 3 WIRE ❑ 277/480V., 3 PHASE. 4VIRE... -. ❑ 480V.. 3PHASE, 3 WIRE MOUNTING: ■ FLUSH 2 MAIN: • LUGS ONLY AMP. ❑ TOP ❑ MAIN BREAKER 200 AMP. C BOTTOM NEUTRAL: • 50% I 100% COVER: 0 DOOR W1H LOCK . DOOR WITHOUT LOCK ALL BREAKERS 20 AMP. 1 POLE UNLESS NOTED OTHERWISE U/L LISTED BREAKER INTERRUPTING CAPACITY : 12000 RMS SYM. AMPS. CONNECTED LOAD: PHASE A 6984 W., PHASE 8: 7181 W., PHASE C., 6236 WL, TOTAL 20391 WATTS LOCATION LOAD NO. 65% ABC NO. LOAD LOCATION (63A) L FRONr&BOOTTi LITS 640 1 2 400 #122 M " L FRONT &DINING AREA UTS 710 3 4 „ L DINING AREA LITS 725 5 6 „ L DINING AREA LITS 720 7 8 '• L OUTSIDE LITS 1115 9 10 , I L PARTY & BAR AREA UTS 1035 11 12 , I L WAITER AREA & HOOD LITS 1260 13 14 " L TRACK +2X4 LITS @ KITCHEN 1056 15 16 1I L ?X41.IT @PREP AREA & KITCHEN UTE 576 17 18 „ L COMPUTER RM& RESTROOM ZITS 364 19 20 " L SIGNAGE #114 1500 21 22 „ L SIGNAGE #115 1500 23 24 „ K DISHWASHER 1200 25 26 " 27 28 , I 29 30 11 31 32 " 33 34 11 35 36 „ 37 38 " , I 39 40 \ / \/ \./ 41 42 CONNECTED LOAD 18,400 800 36,000 5,000 60,200 107 LOAD FACTOR 100% 125% 100% 65% COMPUTED LOAD 18,400 1000 36,000 3250 58,650 163 CONNECTED LOAD 11.800 1.400 0 31,700 44,900 125 LOAD FACTOR 100% 125% 100% 65% COMPUTED LOAD 11,800 1,750 0 20,605 34,155 95 CONNECTED LOAD 8,000 11,191 0 1,200 20.391 57 LOAD FACTOR 100% 125% 100% 65% COMPUTED LOAD 8,000 13,988 0 780 22,768 63 CONNECTED LOAD 8,150 3.000 0 50,750 61,900 172 LOAD FACTOR 100% 125% 100% 65% COMPUTED LOAD 8,150 3,750 0 32,987 44,887 125 Q uIPv FAT LIST LOAD CALCULATIONS (EPA) LOAD SUMMARY MISC. LOAD CALCULATIONS (EPC) LOAD SUMMARY MISC. LIGHTING LIGHTING HVAC HVAC KITCHEN TOTAL KITCHEN TOTAL AMP AMP *F ELD VERFTED NOTES: ALL WIRES SHALL BE PHASE A- BLACK, PHASE B- RED, PHASE C- BLUE + NEUTRAL - WHITE AND SHALL BE #12 COPPER MIN., THHN OR OTHERWISE NOTED. LOAD CALCULATIONS (EPB) LOAD SUMMARY MISC. LOAD CALCULATIONS (EP D) LOAD SUMMARY MISC. LIGHTING LIGHTING HVAC H VAC KITCHEN KITCHEN TOTAL TOTAL AMP AMP FL07- (sO DEC 31 Z007 PE3IT CENTEF, @FA EN D E S 1 G N S T U D I O PLANNtIG MD INTERIOR DESIGN 1405 BOYLSTON AVE SEATTLE WA 98122 TEL 2063224323 E- MAL1FOcCATCHBTt1D10.0014 WWW,CATC✓I1STUDIO.COM ENCEEER Jan, BLA'CKLAW 7224 JAMB 1a SW R WA 9 a.):P1RES 2 Inc DESIGN BARCIREEN EIL.INGSON 36271 ST AVE SOUTH SEATTLE ,WA 98134 PHOte 206.6821472 FAX: 2013.6822367 PRO, ECT TITLE: SHEET TITLE SEEN WESTFED MALL ( 11iVI .A, WA) Ea LIST. PANEL SCEEDULES DESICitt CATCH DESIGN STUDIO DRAW* THOMAS 1.1 DATE 12/26/07 SCALE AS NOTE E4