Loading...
HomeMy WebLinkAboutPermit EL07-723 - WESTFIELD SOUTHCENTER MALL - PANDA EXPRESSPANDA EXPRESS 2600 SOIJThCENTER MALL FC-10 ELO7-723 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http:• / /www.ci.tukwila.wa.us 6364200010 2600 SOUTHCENTER MALL TUKW PANDA EXPRESS 2600 SOUTHCENTER MALL, #FC -10 , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA CHARLES LEA 1683 WALNUT GROVE AV , ROSEMEAD CA JACK BRODHEAD ELECTRICAL CNTRG Address: 11 RASPBERRY LN , ELMA WA Contractor License No: JACKBBE946QA ELECTRICAL PERMIT DESCRIPTION OF WORK: TENANT IMPROVEMENT: INSTALL (2) NEW SUB - PANELS AND (1) SET 45 KVA TR NEW LIGHTING, AND ALL NEW KITCHEN EQUIPMENT. Permit Number: Issue Date: Permit Expires On: Phone: Phone: 626 280 -9188 Phone: 360 859 -1121 Expiration Date: 11/01/2008 ELM-723 04/30/2008 10/27/2008 Value of Electrical: $20,000.00 Fees Collected: $512.50 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: ( P� Date: `270W u I hereby certify that I have read and ex governing this work will be complied v L ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit. Signature: Date: 36/" Print Name: 7 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL07 -723 Printed: 04 -30 -2008 1: ** *ELECTRICAL * ** Signature: doc: Cond -Eiec Print Name: '. O//4( t TSEG City of Tukwila Parcel No.: 6364200010 Address: 2600 SOUTHCENTER MALL TUKW Suite No: Tenant: PANDA EXPRESS Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: ELO7 -723 Status: ISSUED Applied Date: 11/28/2007 Issue Date: 04/30/2008 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Date: OZ P EL07 -723 Printed: 04 -30 -2008 SITE LOCATION Site Address: Name: E -Mail Address: Company Name: CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Tenant Name: P NOA ,Ss Property Owners Name: 11/.05r Keg Mailing Address: //66/ W/ /eE 9 (hA 1 X Mailing Address: /A6-3 42&10" fi'✓� ELECTRICAL CONTRACTOR INFORMATION 11 -Appl icmions Foram- Applications On Linc42007 - tilectncal Permit Apphcmion.doc bh Electrical Permit No. VA' 1 Project No. (For office use only) King Co Assessor's Tax No.: (.19 20 — C30(a L ( Suite Number: Floor: 2 New Tenant: 7 Yes ❑..No City Fax Number: State 9a� Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Day Telephone: 4z6 .22940 / /I • iPDS r�� L°04 4/77d City State Zip O Mailing Address: State City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Zip Valuation of Project (contractor's bid price): $ L?� Scope of Work (please provide detailed information): T .t ,/e PIMA tP SS e lame e! zt_ _ /NS1741-L 2 / 74 1 . S . / ssri 4rS 4 7 N 'v 146#774/4.- Aivv c. Nom( i it '-N / &Aar/it/yr xTC . . Will service be altered? ❑ Yes ❑ No Adding more than 50 amps? ❑ Yes ❑ No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel 16 Tenant Improvement ❑ Low Voltage ❑ Generator El Fire Alarm El Telecommunication ❑ Temporary Service Property Served by: R] Puget Sound Energy ❑ Seattle City Light Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) BUILDING OWNER OR ELECTRICAL CONTRACTOR: I Date Application Accepted: II: Applications Fonns- Applications On Line 4-2007 - Electrical Permit Application.doc bh 24. log 6(4-- Date Application Expires: Day Telephone: City MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Camivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. Vb. Date: /`22 -o7 Signature: Print Name: ,',�' ,., ,A Mailing Address: 168 L�W�L/t/ // 7 L � geSE/ E/4P / 'A- 1/ 772 State Zip bz6 .yige Staff Initials: Page 2 of 2 Receipt No.: R08 -01414 Initials: JEM User ID: 1165 Payee: JACK BRODHEAD TRANSACTION LIST: Type Method Descriptio Amount Payment Check 5432 410.00 ACCOUNT ITEM LIST: Description ELECTRICAL PERMIT - NONR City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL07 -723 Address: 2600 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 11/28/2007 Applicant: PANDA EXPRESS Issue Date: Account Code Current Pmts 000.322.101.00.0 410.00 Total: $410.00 Payment Amount: $410.00 Payment Date: 04/30/2008 09:19 AM Balance: $0.00 1816 04/30 9711 TOTAL 410.00 doc: Receipt -06 Printed: 04 -30 -2008 RECEIPT NO: R07 -02599 Initials: JEM Payment Date: 11/28/2007 User ID: 1165 Total Payment: 1,105.13 Payee: CAL ARC DESIGN STUDIO, INC. SET ID: S000000903 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount r► City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us D07 -437 800.79 EL07 -723 102.50 M07 -256 128.59 PG07 -318 73.25 TOTAL: 1,105.13 TRANSACTION LIST: Type Method Description Amount Payment Check 833 ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES SET RECEIPT TOTAL: 1,105.13 1,105.13 Account Code Current Pmts 000.345.832.00.0 102.50 000/345.830 1,002.63 TOTAL: 1,105.13 5432 11/28 9710 TOTAL 1105.13 Project: p / _ � Type of Inspection: Zion Address: ' K am, Date Called: Special Instructions: r Date Wanted: 1 0� a, .m. Requester: Phone No: 'inspector: /0c INSPECTION RECORD Retain a copy with permit L INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3: 70 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Cptku tV6 � r[`�� r $60.00 REIN FEE REQUIRED. Prior to inspection, fee e must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Pro * ,(J t6 Type of Inspect: A2' S _ f /'. `// V Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: INSPECTION NO. O CITY OF TUKWILA BUILDING DIVISION I 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36170 r3 4Poved per applicable codes. Corrections required prior to approval. COMMENTS: -70v2_ " /9 ;quv c/v4 (7j. -64/or nmOUe:s F62 RrroF 17/ EWInMIivr Inspector, LL , / yi - `Date: _ 5 / � $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. INSPECTION RECORD Retain a copy with permit P RMI 'Receipt No.: 'Date: COMMENTS:,, Ater E SPA t P E 1 CA ECV Ir' «�rP 11 RE&'J(a futtemitp LA6a5 tituktilurwr ATR040 ._.._ -0 c IniTO w�c x I kat 5fati-Lf 14StD6 i - co J M t.SS I 4Gt old 1A)ht. & t cop Lek E VrfD -rD 6bAID Far TO ctL - D L p�t,l L�r.4 P�� s 1 14 DRATI hhi Vb LT Mg 6 A/Vi. Plus e rotA(5 fol. D «C '6k6 T' • Voi-rg S'5' 1J 0461. of t- tc1l! -T5 To 6 DA) w tT4 t Lb UtL LAct N Tlfsi A c c &M Project: 04-- p ( r / 5 ' C j Type of Inspectio ! � Address: 00 Date Called: Special Instructions: Date Wanted: 1/,5 a r Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 J Approved per applicable codes. 1 Inspector: 611-1 Corrections required prior to approval. &W"' e (Date: D - 7 / t C / O ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: (Date: Project: �� , sacs T ype of Inspection: ?° Z_ Address: Date Called: Special Instructions: Date Wanted: Vic Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION I? 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 D Approved per applicable codes. COMMENTS: jJ(or AU s a tit Pticntr'. pct) oR Inspector: j -7 - 1 / 3? k„ Date: D71/S o El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: Curl -123 Corrections required prior to approval. ... 4 w w- o.ws:.ak Project: i A 602455 Type of Inspection: 1002 Address: ZG 0 0 Date Called: Special Instructions: Date Wanted: -7/07 a Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ID Approved per applicable codes. Corrections required prior to approval. COMMENTS: — �oJ�� auass r6 — Borip �T -cow - s7R�P tie ►d ?CFhR sPA -c.E J Inspector: ,1 j f' ?Y 1Date: 0 7o0 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Prr�� ct • / i/' fix! /�f5,,,s Ty e of Insp tion: ^ ." /y� <j Address: Date Called: Special Instructions: Date Wanted: 6/7 a Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit Inspey jI - / 1/ ERMIT N CITY OF TUKWILA BUILDING DIVISION ER 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 OMM ENTS:_4 04 c .6 - - `proved per applicable codes. El Corrections required prior to approval. Dater / !) $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project: 04 ( ei _ ' _ � Type of Inspection: w ©D Address: � 00 Ar , j / A � Date Called: Special Instructions: Date Wanted: a Requester: Phone No: f } INSPECTION RECORD Retain a copy with permit 67 -77-3 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION - 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: r jJr(6CC --r-Lo -6-0) c a o bsiTE Cpe,I c-KS aF 'ei5tjtC. v1/4/ICE Approved per applicable codes. Corrections required prior to approval. 'Inspector: 6 6 4/ 6 ? ..., 'Date: D4 i 1 o ' $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Prl? , S Ly.,445c C ldress: Type of Inspe.yon• 7-Gov ....bifiHeliv714.432u.„ Date Called: Special Instructions: Date Wanted St Requester: Phone No: le az. INSPECTION RECORD Retain a copy with permit KJ07- 72-3 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION AO- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 206 431- cD ,pproved per applicable codes. EI Corrections required prior to approval. COMMENTS: - i4 S- ,Mr ,w04/4 /MLL1414/ Ins pecto fX/t 44,0IDatea/J-4 EJ $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Pr 4 eect � :: /, �� / 'l in 8(/ ����jj " / & 5( Type of Inspection: -20-0 _7 Address: /�/ 6(J Jd'wcid i /49 Date Called: Special Instructions: Date Wanted: ‘ / 7 a ,lam" Requester: Phone No: 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Southcenter Blvd., #100, Tukwila, WA 98188 (2 06)43 1 -3670 OMMENTS: p4 I - /AMU, CAW proved per applicable codes. El Corrections required prior to approval. Inspe 1 rate: � r El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project Info Project Address Number of Fixtures Date iR13/1EDVVE 633 SOUTHCENTER PKWY., SPACE Fc -10 TUKWILA, WA 98188 For Building D tl LUM NFPA 70 JAN _ 2 JAN �/ i 8 Applicant Name: Charles Lea Applicant Address: 1683 Walnut Grove Ave., Rosemead, CA 91770 Applicant Phone: 626.280. tiles Project Description II New Building II Addition •� Alteration • Plans Indud . City Of Refer to WSEC Section 1513 for controls and commissioning requirem nts8UT1 n (' �+ Compliance Option 0 Prescriptive • Lighting Power Allowance (See Qualification Checklist (over). Indicate Prescriptive & LPA 0 Systems Analysis spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) 3 • No changes are being made to the lighting 105.0 • Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed 100 A RECESSED MIL Halide LTG 8 37.0 296.0 100 B RECESSED ADS BOULE MR 111 LTG 5 50.0 250.0 no D SURFACE MTD. MR -16 3 35.0 105.0 101 E -1 RECESSED COMBO LTG 2 75.0 150.0 101 E -2 RECESSED COMBO LTG 3 75.0 225.0 101 8 2X4 3 -T -8 Fluor. LTG 7 64.0 448.0 Location (floor /room no.) Occupancy Description Allowed Watts per f12** Area in fly Allowed x Area 100 Service Area Food Display 1.30 190.0 247.0 101 Kitchen Area 1.33 944.0 1255.5 1 2006 Washington State Nonresidential Energy Code Compliance Forms 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary LTG -INT Maximum Allowed Lighting Wattage " From Table 15-1 (over) - document all exceptions on form LTG -LPA Proposed Lighting Wattage Total Proposed Watts may not exceed Total Allowed Watts for Interior Revised Jy.V ; Total Allowed Watt 1502.5 Total Proposed Watt s) 1474 .0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, Tamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, fist the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. INCOMPLETE LTR# RECEIVED DEC 17 2007 E LO '1 723 SITE CO.ti .=NTER D FOR P LIANCE - NEC 2Uua ION Lighting Power Allowance Adjustments LTG -LPA 2006 Washington State Nonresidential Energy Code Compliance Forms 2006 Washington State Nonresidential Energy Code Compliance Form Revised July 2007 Project Address 1 633 SOUTHCENTER PKWY., SPACE 8C -10 I Date 12/12/2007 Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for interior fighting. The Occupancy Description should agree with the "Use" fisted on Code Table 15-1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft Carry the Adjusted LPA to the corresponding "Allowed Watts per ft location on LTG -SUM. Adjusted Lighting Power Allowances (Interior) Location (floor /room no.) 100 101 Occupancy Description Service Area Kitchen Area Allowed Watts per ft2 ** 1.30 1.30 Ceiling Height for this room 12.0 feet 10.0 feet Ceiling Height limit for this exception" 12 feet 9 feet Adjusted LPA Watts per ft' 1.30 1.33 " From Table 15-1 based on exceptions listed in footnotes RECEN f_ DEC 1 -7 2007 PERMIT CENTE 04 -04 -2008 CHARLES LEA 1683 WALNUT GROVE AV ROSEMEAD CA 91770 RE: Permit Application No. EL07 -723 2600 SOUTHCENTER MALL TUKW Dear Permit Applicant: In reviewing our current permit application files, it appears that your permit application applied for on 11/28/2007 , has not been issued by the City of Tukwila Permit Center. Per the International Codes, Uniform Plumbing Code and/or the National Electrical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 05/26/2008 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 05/26/2008. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: fer Marshall 't Technician Permit File No. ELO7 -723 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 November 29, 2007 Charles Lea 1683 Walnut Grove Av Rosemead CA 91770 RE: Letter of Incomplete Application # 1 Electrical Permit Application EL07 -723 Panda Express — 2600 Southcenter Mall FC -10 Dear Mr. Lea, City of Tukwila Steven M Mullet, Mayor Department of Community Development Steve Lancaster, Director This letter is to inform you that your permit application received at the City of Tukwila Permit Center on November 27, 2007 is determined to be incomplete. Before your application can continue the plan review process the following item from the following department needs to be addressed: Building Department: Bill Buterbaugh, at 206 973 -4758, if you have any questions concerning the following comments. Enclosures File: ELM-723 1. Provide Washington State Energy Code Lighting Budget Calculations. Please address the comment above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that three (3) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206)431 -3670. Sincerely, J; nni -r Marshall P Technician P:\Permit Center\Incomplete Letters\2007\ELO7 -723 Incomplete Ltr #1.DOC ]em 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: EL07 -723 DATE: 12 -17 -07 PROJECT NAME: PANDA EXPRESS SITE ADDRESS: 2600 SOUTHCENTER MALL FC -10 Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # After Permit Issued DEPPARTMEENTS: Bukg Diliis Complete TUES/THURS ROAITING: Please Route wERMIT COORD COPY'' PLAN REVIEW /ROUTING SLIP APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: Documents/routing slip.doc 2 -28 -02 Fire Prevention Planning Division Public Works ❑ Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12 -20 -07 Incomplete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Structural Review Required Not Applicable ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 01 -17 -08 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: C u Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DEPARTMENTS: 11° ,° B ing Public Works ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg Fire ❑ REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL07 - 723 DATE: 11 -28 -07 PROJECT NAME: PANDA EXPRESS SITE ADDRESS: 2600 SOUTHCENTER MALL, FC -10 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Th rs.) DUE DATE: 11-29-07 Complete ❑ Incomplete Not Applicable n vatoi- LETTER OF COMPLETENESS MAILED: Ping ❑ PW ❑ Staff Initials: 601/ TUES/THURS ROUTING: Please Route ❑ Structural Review Required n No further Review Required DATE: DATE: Planning Division Permit Coordinator Approved n Approved with Conditions C Not Approved (attach comments) Notation: REVIEWER'S INITIALS: n C n DUE DATE: 1 2-27 -07 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Date: / ilr / Created: 8 -13 -2004 r1..ria.a• City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail; fax; etc Plan Check/Permit Number: 7- 72_ 3 Steven M Mullet, Mayor Steve Lancaster, Director Response to Incomplete Letter # ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: /IAA JN ()reS 5 Project Address: ,�,,//(o 00 So crv�- t'1r�R1 C - to Contact Person: (,Y) ,fi g 4 Phone Number: to 2-4 —Z Y 9/ �� Summary of Revision: RECEIVED .CITY OF Ti iuw/L/1i IDEC 17 20071 FEFiM1 T CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision iO Received at the City of Tukwila Permit Center by: ❑ Entered in Permits Plus on \)=A '• fl 1applicationslforms- applications on line\revision submittal License Information License JACKBBE946QA Licensee Name JACK BRODHEAD ELECTRICAL CNTRG Licensee Type ELECTRICAL CONTRACTOR UBI 602660876 Ind. Ins. Account Id Business Type INDIVIDUAL Address 1 11 RASPBERRY LN Address 2 City ELMA County GRAYS HARBOR State WA Zip 98541 Phone 3605891121 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 11/1/2006 Expiration Date 11/1/2008 Suspend Date Separation Date Parent Company Previous License Next License Associated License BRODHJH941QB Business Owner Information Name Role Effective Date Expiration Date BRODHEAD, JACK OWNER 11/01/2006 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Electrical Administrator Information License Name Status BRODHJH941QB BRODHEAD, JACK H ACTIVE Bond Information Bond https:// fortress .wa.gov /lni/bbip /printer.aspx ?License= JACKBBE946QA 04/30/2008 ELECTRICAL EQUIPMENT LIST & CONNECTION SCHEDULE O MAIN BREAKER Dia A.F. 200A- 3PA.T. BOTTOM FEED ❑ FLUSH MTG. ❑ REMARKS LUGS ONLY CONNECTION MTG HT. REMARKS OUTLETS EINEM GUARD U Y F-' BUS ABC C-) 1- 6 OUTLETS J 0 J) 3 PAN FOOD WAFWER (2) DESCRIPTION A B C L COUNITER TOP COOKER/WARAER (2) M L R M A BEVERAGE DISPENSER C EF -1 (5HP) 2105 CARBONATOR 5 1 15A /3P 1 900LB ICE MACHINE 2 4 70A /3P - 1 COUNTERTOP DISPLAY CAFE 14070 14241 1200 45KVA X'MER - - FRYER 2105 • 6 WALK-91 COOLER CONDENEEFI - 3 6 ALL COOLER CIICIATTIM BE ROUTED TO • WALK-IN EVAPORATOR 1 5000 COMMON JBBOX MOUNTED AT 130' AFF. 13694 WALK-IN COOLER LIGHTS - 1 WITH FLEXIBLE CONPECTION6 TO UNIT 1600 55' HEUER WARMER #3D - - 5 REF. PFEP TABLE e 1 DRUM CORD S6 /S3 REF. PREP TABLE 500 7 iii ;; 8 10 72' LOW PROFLE COOICO STAND r " 12 - BLINDER 9 12 14 - - BLENDER 540 5000 GAS WATER BATH STATION 3 14 20A /3P 1 1600 DROPPED CORD SHP -1 CASH REGISTER 850 • VE#FY Mm HT. WITH CASEWORK MANUF. COO.FUTER PAWS 25A/3P 13 - 3213 FAX • - HOOD CONTROL PANEL „ „ IN 11 1i 16 18 - SEE M-23 CONTROL DIAGRAM DOOR BELL • „ - SECURITY CAMERA 20 SECURITY VCR 20A /1P 17 „ 18 SECURITY MONroR 20A /1P 1 WATER HEATER 19 ROOF REC. DISPENSOR #4A /11E 1920 ID.SK3N 2 LOGO BKIN 19 „ 20A /1P 20A /1P PHOT BOX 2 1 24 AENIIBOARD RICE WARMER #55 SNEEZE GUARD #2 W.I. FREEZER 1000 277/480 30, 4W. PANEL H LOCATION KITCHEN VOLTAGE BUS AMPS 225 TOP FEED ® SURFACE MTG.❑ MAIN BREAKER Dia A.F. 200A- 3PA.T. BOTTOM FEED ❑ FLUSH MTG. ❑ REMARKS LUGS ONLY DESCRIPTION VOLT -AMPS IJ U J OUTLETS U CO U Y F-' BUS ABC C-) 1- U m OUTLETS J 0 J) VOLT -AMPS DESCRIPTION A B C L R M L R M A B C EF -1 (5HP) 2105 • 5 1 15A /3P 1 ;; �; 2 4 70A /3P - 1 14070 14241 1200 45KVA X'MER - - 2105 • 6 - 3 6 - 30A /3P - • 4 1 5000 • 5000 13694 - EWH - - 1 2105 1600 1600 WARMER #3D - - 5 e 1 S6 /S3 500 7 iii ;; 8 10 1 r " 12 - 9 12 14 - - POS #87/83A/81 540 5000 - 3 14 20A /3P 1 1600 11 SHP -1 3213 850 • 1 25A/3P 13 - 3213 • - 15 „ „ IN 11 1i 16 18 - 850 3213 • „ - 17 20 20A /1P 17 „ 18 20 20A /1P 1 180 19 ROOF REC. DISPENSOR #4A /11E 1920 2 20A /1P 19 „ 20A /1P 20A /1P 2 1 24 1600 RICE WARMER #55 SNEEZE GUARD #2 W.I. FREEZER 1000 I-- 1 20A /1P /1P 21 23 ,r sr, , a 22 24 FINE/SMOKE ALARM SYS 180 23 26 28 *20A 26 28 20A /1P 20A /1P 20A /1P 1 1 1 1200 1200 660 REFRIG. 32G PREP. TABLE #34A FREEZER #34D HOOD LTG 750 • 10 25 20A /1P 20A /1P 20A /1P 15A/2P - 25 27 29 31 33 M4 ANSUL 700 27 1 I , 30 W.I. COOLER #31 500 1 32 20A /1P 20A /2P - 2 1 1800 1144 11 aka la 34 36 38 40 FC 500 `-� �`'� --_ 34 - 500 ,; LI 36 MICROWAVE #55 850 �^, /- 1 33 35 38 40 l .r -- 2 2 1300 1576 35 BLENDER #46A PREP. #45A SPARE - 850 37 37 COMP. RACK 2000 39 „ ; ; 42 - 2000 SUB TOTALS 5690 6061 4870 8880 8680 7804 41 SUB TOTALS 5318 5318 5318 19070 19241 18694 SUB TOTALS 24388 24559 24012 72959 VA; MAX. CONN. LINE CURRENT S AMPS CONN. PHASE TOTAL: A B C ; CONN. PANEL TOTAL 72.96 2.41 75.37 KVA; BALANCED CURRENT 91 AMPS; DESIGN LOAD KVA (KVA) PANEL TOTAL + L.C.L (,25) = 120/208 30, 4W. PANEL A LOCATION KITCHEN VOLTAGE BUS AMPS 225 TOP FEED ® SURFACE MTG.❑ MAIN BREAKER IN A.F. 150 A.T. BOTTOM FEED ❑ FLUSH MTG. XI ❑ REMARKS LUGS ONLY DESCRIPTION VOLT -AMPS 1 0 J OUTLETS U CO UYF- BUS ABC 0 1- U CO J OUTLETS 0 JI VOLT -AMPS DESCRIPTION A B C L R M L R M A B C 'LTG 435 • 5 *20A /1P 20A /1P 1 3 T1 'm m ma MI „ 2 4 6 20A /3P - - 1 1200 1200 1200 WARMER #3C - - LTG 511 • 6 TRACK LTG 800 • 4 20A /1P 20A /1P 20A /1P 20A /1P 5 7 9 11 8 10 20A /3P - 1 1600 1600 WARMER #3D - LTG 385 e 1 S6 /S3 500 • 1 r " 12 - 1600 - POS #87/83A/81 540 3 14 20A /3P 1 1600 WARMER #3D MICROWAVE #55 850 1 20A /2P - 13 15 - - 1600 1600 - - - 850 „ 16 SPARE 20A /1P 17 „ 18 20 20A /1P 1 180 ROOF REC. DISPENSOR #4A /11E 1920 2 20A /1P 19 „ 20A /1P 20A /1P 2 1 360 1600 RICE WARMER #55 SNEEZE GUARD #2 W.I. FREEZER 1000 1 20A /1P /1P 21 23 ,r sr, , a 22 24 FINE/SMOKE ALARM SYS 180 *20A 26 28 20A /1P 20A /1P 20A /1P 1 1 1 1200 1200 660 REFRIG. 32G PREP. TABLE #34A FREEZER #34D HOOD LTG 750 • 10 20A /1P 20A /1P 20A /1P 15A/2P - 25 27 29 31 33 M4 ANSUL 700 1 I , 30 W.I. COOLER #31 500 1 32 20A /1P 20A /2P - 2 1 1800 1144 1144 FRYER #21B/24E ICE MAKER #10F - FC 500 1 SE ri 34 - 500 ,; LI 36 MICROWAVE #55 850 1 20A /2P 35 38 40 20A /1P 20A /1P 2 2 1300 1576 BLENDER #46A PREP. #45A SPARE - 850 - 37 COMP. RACK 2000 30A /1P 39 41 ; ; 42 - 2000 SUB TOTALS 5690 6061 4870 8880 8680 7804 SUB TOTALS 14570 14741 12674 41985 VA; MAX. CONN. LINE CURRENT 123 AMPS CONN. PHASE TOTAL: A B C ; CONN. PANEL TOTAL 41.99 0.85 42.83 CURRENT 119 AMPS; DESIGN LOAD KVA (KVA) PANEL TOTAL + L.C.L. (,25) = KVA; BALANCED TO EXITSIGN /EM. LTG C O f C t H - * * PANEL NOTES * . PROVIDE LOCK ON DEVICE * * EF -1 & MUA -1 CONTROL DIAGRAM SEE MECH. DWG. PANEL NOTE: PROVIDE COMPLETE TYPEWRITTEN IDENTIFICATION DIRECTORY CARD FOR ALL MAIN AND BRANCH CIRCUITS IN THE PANEL DOOR. ROOF PLAN NOTES: 1. ALL EQUIPMENT ON ROOF SHALL BE WEATHERPROOF. 2. ALL WIRING ROUTED ON ROOF SHALL HAVE TYPE THW INSULATION, EXCEPT AS NOTED OTHERWISE. 3. VERIFY EXACT LOCATION OF ALL EQUIPMENT & CONNECTION POINTS WITH AIR CONDITIONING & REFRIGERATION CONTRACTORS. 4. PROVIDE PERMANENT IDENTIFICATION, PAINT OR ENGRAVED NAMEPLATES, ON DISCONNECT SWITCHES & CONTROL EQUIPMENT, WHERE NOT OBVIOUS MARKING PEN OR TAPE ARE NOT ACCEPTABLE. 5. SEE MECHANICAL SHEET "M -1.0" FOR EXACT LOCATIONS OF MECHANICAL EQUIPMENT AND STUB -UP LOCATIONS. 6. SEE MECHANICAL DWG. FOR AIR CONDITIONING CONTROL WIRING. 7. ALL CONNECTIONS TO AIR CONDITIONING EQUIPMENT SHALL BE MADE WITH SEALTITE FLEX. 8. ELECTRICAL CONTRACTOR SHALL INSTALL LOW VOLTAGE CONTROL WIRING FOR AIR CONDITIONING UNITS. AIR CONDITIONING CONTRACTOR SHALL MAKE FINAL CONNECTIONS AT T -STATS & AIR CONDITIONING UNITS, TYPICAL. 9. ALL LOW VOLTAGE WIRING SHALL BE COLOR CODED AS DIRECTED BY AIR CONDITIONING CONTRACTOR. 10. ALL CONDUITS PROJECTING THROUGH ROOF MUST HAVE G.I. ROOF JACKS INSTALLED BEFORE ANY ROOFING IS INSTALLED. ROOFER SHALL ROOF IN JACKS. APPLYING JACKS AFTER ROOFING HAS BEEN COMPLETED IS NOT PERMITTED 11. ELECTRICAL CONTRACTOR SHALL INSTALL & SEAL COUNTER FLASHING ON ALL CONDUITS. 12. ALL CONDUITS TO EQUIPMENT ON ROOF SHALL BE ROUTED IN SPACE ABOVE CEILING & STUBBED UP AS NEAR AS POSSIBLE TO POINT OF CONNECTION. DO NOT ROUTE CONDUITS ON ROOF EXCEPT AS REQUIRED FROM STUB UP LOCATION. ALSO VERIFY EXACT CONNECTION POINT IN UNITS WITH AIR CONDITIONING CONTRACTOR. CONNECTION POINT MAY NOT BE AT POINT OF ENTRY TO EQUIPMENT. u 1 27' i L_ J BOX PROVIDE BY ELECTRICIAN. MIN. 12" A.F.F. FLANGE CONDUIT BOLT TO F.F. u--S.S. 1 -5/8" DIA. 44- TUBE. COREDRILL 6" 3 t /4' INTO FINISH FLOOR. S.S. OUTLET DETAIL SCALE: NTS POWER PLAN NOTES: 1. VERIFY ALL HVAC & KITCHEN EQUIPMENT PRIOR TO ROUGH IN PROTECT EXISTING A/C UNIT BRANCH CIRCUITS AND CONNECT TO NEW PANEL AS SHOWN. 2. COMPUTER DATA LINE: ROUTE 1" CONDUIT FROM MANAGER STATION ( ©24 ") TO CASH REGISTER (4124 ") W /PULL STRING. 3. PHONE LINE: PULLPHONE WIRE & INSTALL PHONE JACK FOR MAIN PHONE LINE (MANAGER STATION AT 48" , CASH REGISTER 24 ") FAX LINE (MANAGER STATION AT 24 ") CREDIT CARD LINE (CASH REGISTER 24 ") 4. POWER SUPPLY FOR COMPUTER, CASH REGISTER (83, 86, 87A, 81) SHOULD BE ON THE SAME CIRCUIT BREAKER, W/ ORANGE RECEPTACLE. 5. AUDIO /VISUAL ALARMS PLUS SPACE SMOKE DETECTOR(S) SHALL BE INSTALLED AND CONNECTED TO THE MALL FIRE ALARM SYSTEM BY LANDLORD'S CONTRACTOR (SIMPLEX) ® TENANT'S EXPENSE. 6. MUA-1& EF -1 CONTROL DIAGRAM SEE MECH. HOOD CONTROL PANEL. 7. ALL SIGNS COMPLY WITH NEC CODE W/ DEDICATE NEUTRAL TO ALL SIGN C.B.. 8. THE CONDUIT AT THE PENETRATION OF THE FREEZER /COOLER WILL BE SEALED PER NEC ART 300 -7. KEY NOTES 0 STAINLESS STEEL PANEL WITH OUTLETS. SEE DETAIL D PROVIDE CONTINUOUS USE WATER PROOF COVER BOX. PROVIDED (1) 20A -1P SHUNT TRIP BREAKERS IN NEMA 1R ENCLOSURE. TRIPPED BY HOOD CONTROL SYSTEM. O NOT USED. ® VIA TIME SWITCH ABOVE PANEL "A" (E): EXISTING. FIELD TO VERIFY. (R): EXISTING TO BE RELOCATED. FIELD VERIFY CONDITION OF ALL EXISTING EQUIPMENT. REPAIRED OR REPLACED AS REQUIRED. * NOTE FOR CAT 5E CABLE & 4 JACKS AT COMPUTER TOWER & CASH REGISTER. ( i I ) ) i I i ) A -24 30AS /NF NEMA -3 ) ) v F 0 tOrn X N FILE rOPY Permit No.. Plan review apprloNal is sublect to errors and and. Approval of cx mit documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and ; Is adasowledged A -13,15 /c City of Tukwila ON BUILDING DIN [ r:i".:"iSinNIS No changes s'1�=:ill�be rn1 ;n to the sc ono of work without prior approve! of Tukwila wilding Division. NOTE: Revisions will require a new plan submittal : 1r1d may include additional plan re tees ROOF PLAN SCALE: 1/4"=1'-0" ERVICE 11,19 CO P IN ROOF FOR ' CON ..6 vmjmwm:444moim VgmIIe.a.4 PNL "H" A -34,36 - a- -I- - -a- -- 1 1 1 1 36X84 NEMA 6 -20R APPROVED P! ' ': nn` :cIfl CATIONS VAI MODIFIED CR ALTERED WITHouT AUTHORIZATION FROM THE BUILDING 0" ' ALII WORK SHALL GE DONE IN ACCORDANCE WITH THE APPROVED PLANSANF 15 " 3:';� "T TO RFC INSPEOTIONS 4 E P L D T . FIL POWER PLAN SCALE: 1/4"=1'-0" Public Works, Building Division PERMIT NUMBER IG (2) 1"CO TO MANAGER STATION PI CI IVIttJ CITY OF Ti JKwit_A Nov 2 8 2007 1► PANDA RESTAURANT GROUP INC. 1683 Walnut Grove Ave. Rosemead, California 91770 Telephone: 626.1a1.1EGO Facsimile: 626.372.8288 All ideas, designs, arrangement and plans indicated or represented by this drawing are the property of Panda Express Inc. and were created for use on this specific project. None of these ideas, designs, arrangements or plans may be used by or disclosed to any person, firm, or corporation without the written permission of Panda Express Inc. REVISIONS: ISSUE DATE: IST 2ND 3RD 4TH 5Th 1ST SUBMIT DRAWN BY: PANDA PROJECT #: M1- 08 -D1189 HYC PROJECT #: CPC0719 ARCHITECT : 1683 WALNUT GROVE AVE., SUITE #301 ROSEMEAD, CA91770 TEL: 626.280.9188 FAX: 626.280.9189 E -MAIL: INFO @ CALARC. N ET "i'TE ° �� s e l EXPIRES 5/5/ PANDA EXPRESS WESTFIELD SOUTHCENTER SPACE NO. FC -10 633 SOUTHCENTER PKWY., TUKWILA, WA 98188 E-1 POWER PLAN 11 -09 -07 Z:1Cal Arc ProJect107 Project -CAL Arc107 -1 PX construction docurnent1170705 PX (4) South Center Mail, Tukwila, WA M1.03-01109 MEP Only( 0m4)1 170705R1lEleciricallM170133E .dwg, 11113/2007 6:58:14 PM, Oce TOS400 1.x.pc3 SYMBOL MODEL NO. PARTS NO. 2 X QR — LP111 + FRONT GLASS 111 : 268 61 232 NB300 — RB 211 SERIES (2 X 50 W. MR 111 LAMPS & CLEAR COVER GLASS & CLIP ON ACCESSORIES ACCESSORIES HOLDER : 201 27 99 HOLDER RING — MOUNTED INSIDE NB 300 CLIP 111 B — SERIES SUSPENDED RAIL EXTRUSION SYSTEM) GLASS COVER : 201 17 00 FRONT GLASS 111 — SERIES FINISH C6P3OMH + CLW + C639 MHE1 FRAME —IN KIT : C639MHE1 (120V./ 39M` M : WHITE (1 X 39 W. PAR 30 MTL. HALIDE LAMP ELECTOR TRIM : CLW — WHITE FLANGfREFLECTOR : SPECULAR 120 V. ELECT. BALLAST) W/ SPECULAR CLEAR REFLECTCR)CLEAR FIXTURE : BLACK ACCESSORIES HOLDER : BLACK 120 0 OEM UMW TYPE A B C D E -1 E- 2 H J K L DESCRIPTION RECESSED PAR 30 METAL HALIDE LIGHTOLIER DOWNLIGHT (FLOOD — 39 W. PAR 30 LAMP) RECESSED ADJUSTABLE DOUBLE LAMP MR -111 HALOGEN ACCENT (WIDE FLOOD — 50 W. LAMPS) MANUF'R, DELTA LIGHT SUSPENDED LIGHT RAIL SYSTEM DELTA LIGHT W/ RECESSED LIGHTS AND SURFACE MOUNTED DECORATIVE PENDANT SHADES SURFACE MTD. INCANDESCENT DECORATIVE PENDANT SHADE DELTA LIGHT RECESSED COMBO LIGHT RAIL RSA LIGHTING W/ (2) PAR 30 METAL HALIDE LAMPS & FLUORSCENT STRIP IN MIDDLE (W/ PARABOOLIC LOUVER) RECESSED COMBO LIGHT RAIL RSA LIGHTING W/ (2) PAR 30 METAL HALIDE LAMPS & FLUORSCENT STRIP IN MIDDLE (W/ PARABOOLIC LOUVER) VAPORTIGHT GLASS GLOBE INCAND. SCONCE (AT EXHAUST HOOD) < VAPORTIGHT GLASS GLOBE INCAND. STONCO SCONCE W/ METAL GUARD RECESSED 2' X 4' FLUOR. TROFFER 0 LIGHTING CLEAR PRASMATIC ACRYLIC DIFFUSER R APPROVED EQUAL SLIM LINE SINGLE —LAMP MINIATURE BARTCO 28 W. T -5 FLUOR. STRIP LIGHT (43" QQR ,gqPPROVED EQU'AL SINGLE FACE, BACK MTD. EXIT/ Elv ENURE —LITES GENCY LT. COMBO W/ BATTERY PACK SELF — CONTAINED, WALL MOUNTED SURE —LITES EMERGENCY BATTERY UNIT W/ 2 LIGHT HEADS LIGHT FIXTURE SCHEDULE O O O U CO WATT VOLT 39 NOBODY 300 SERIES W/ RB 211 — (2„7 IEIBHTIRAIL : 268 00 00 ANO RECESSED LAMP MODULES AND "JETSI— §19SP. CABLE : 268 09 06 ANO DECORATIVE PENDANT SHADES NB300 — PROFILE ANO SERIES END CAP : 268 03 01 ALU CLIP 111 B — SERIES CUSTOM CORNER : VERIFY ANGLE CLEAR ANODIZED ALUM. N/A N/A , JETI —S SERIES W/ 60W. "A" LAMP FIXTURE : 271 61 21 3m CANOPY : SILVER W/ 3 METER LONG CABLE SUSPENSION "JET1—S" SERIES SHADE WHITE KIT TO BE INSTALLED ON TYPE "C" ACCESSORIES FOR LIGHT RAIL MOUNTING : SUSPENDED RAIL SYSTEM — SEE ABOVE AS NEEDED 98 CR230M39 — F — T528 — BK — S — 11121Ii3fTURE : CR230M39 "COMBO CLASSIC INSIDE/ FIXTURES : BLAC (2 LIGHT 39 W —, PAR 30 MH W/ 1 ENTER PAR 30 MH 39 W. SERIES" TRIM : INDUSTRAIL SILVER 28 W. T5 FLUOR. CELL) ACCESSORIE : PARABOLIC LOUVERS W/ CLEAR ACRYLIC LENS 120 105 CR230M39 — F — T535 — BK — S — 1MTURE : CR230M39 "COMBO W. SE CLASSIC INSIDE/ FIXTURES : BAC (2 LIGHT 39 W —, PAR 30 MH W/ 1 :.ENTER PAR 30 MH 35 W. T5 FLUOR. CELL) ACCESSORIE : PARABOLIC LOUVERS W/ CLEAR ACRYLIC LENS 120 BY HOOD MANUFACTURER VCXL11 GC — VGP 100 W/ J —BOX ADAPTER PLATE GLOBE : CLEAR PRISMATIC 75 GLASS GUARD : CAST ALUM. 120 GHL320 — 4 — 4R — FSW — PA — ESB — 277 (4 — T8 LAMPS & ELECTRONIC BALLAST) TRIM : WHITE 128 LENS : CLEAR PRISMATIC ACRYLIC 277 MI T5 — 1T — 28 — 120 (W/ T5 INTEGRAL ELECTRONIC BALLAST) WHITE CCX — 3 1 — G WH ON (CEILING WH WHITE/ NO ARROWS FACE "GREEN" N HOUSING : WHITE LETTERS : GREEN 120 CC — 6 — WH (WALL MOUNTED) WHITE LAMP REMARKS (SEE LEFT) PHILLIPS - 35 W. "MASTER CO.. PAR 30L CERAMIC MTL. HALIDE O # CDM35/ PAR3OL/ M/ FL (FLOOD) OSRAM SYLVANIA — 50 W. MP1 HALOGEN W/ ALUM. REFLECTOR 1 O O (25 FLOOD) # 50AR111 / FL25 (2) LAMP REQUIRED PER FIXTURE NOT APPLICABLE O 0 10 PHILLIPS 60W. " HALOGENA" BT -15 FROSTED 120 VOLT # BC6OBT 15/ HAL/ W O O O PHILLIPS — 35 W. "MASTER CO_ 2' 0 O PAR 30L CERAMIC MTL. HALIDE # CDM35/ PAR3OL/ M/ FL (FLOC) "SILHOUETTE" 28 W. T5 FLUOR. #F28T5/ 835/ ALTO (3500 K TEMP.) PHILLIPS - 35 W. "MASTER CO_ 1 ' O PAR 30L CERAMIC MTL. HALIDE # CDM35/ PAR3OL/ M/ FL (FLOC "SILHOUETTE" 35 W. T5 FLUOR. #F35T5/ 835 (3500 K TEMP.) BY HOOD MANUFACTURER 12 PHILLIPS - 60W. "HALOGENA" O 8 BT -15 FROSTED 120 VOLT # 60 BT15/ HAL/ SW (HALOGENA) GENERAL ELECTRIC - (4) 32 W. T8 4100K FLUOR. STRIP (48" L. , 6 # F32 T8/ SPX41 (4 REQ'D.; PHILIPS - "SILHOUETTE" 28 W. FLUOR. 3500K FLUOR. STRIP (- #F28T5/ 835/ ALTO (3500 K TE AC INCANDSECENT : (2) 145V, 1 T6 CANDELBRA BASE LAMPS 2 PER MANUFACTURER (2) - PAR 36 LAMPS LIGHT FIXTURE SCHEDULE KEYNOTES : O CONTACT MANUFACTURER'S LOCAL REP FOR FINALIZING THE SPECIFICATIONS AND EXACT PART NUMBERS FOR ALL "DELTA LIGHT" PRODUCTS: CONTACT : ANYA ORTEL PERFORMANCE LIGHTING SYSTEMS IRVINE, CA OFFICE : (800) 352 -3055 MOBILE : (310) 739 -2315 VERIFY COMPATIBILITY OF LAMP SPECIFIED WITH THE LIGHT FIXTURE & BALLAST TYPE PROVIDED BY THE MANUFACTURER PRIOR TO BIDDING OR ORDERING - NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. NO SUBSTITUTION FOR LIGHT FIXTURES AND LAMPS SPECIFIED IS GRANTED WITHOUT PRIOR WRITTEN APPROVAL OF THE ARCHITECT. FIXTURE TO INCLUDE MANUFACTURER - G ELECT. CONTRACTOR FEEDS, CONNECTORS SHATTERPROOF SAFETY GLASS INSTALLED BY THE .C. TO VERIFY TO FURNISH & INSTALL LIGHT FIXTURE, TRACK, LAMP, POWER & MISC. HARDWARE AS REQ'D. FOR INSTALLATION. PROVIDE "RAPID . START" ELECTRONIC BALLAST SEE REFLECTED CEILING PLAN, ARCHITECTURAL PLANS & DETAILS FOR MORE INFORMATION. FIELD VERIFY HOUSING AND BALLAST SIZE AND INSTALLATION CLEARANCE REQUIRE- MENTS DUE TO CLEARANCE LIMITATIONS WITH EXISTING CONSTRUCTION PRIOR TO ORDERING. CONCEALED ULTRA -SLIM PROFILE FLUORESCENT STRIP TO ACT AS BACK LIGHT FOR DECORATIVE RESIN PANEL AT TOP OF WALL - TO BE MOUNTED AT TOP AND BOTTOM INSIDE RECESSED COVES - PROVIDE ACCESS FROM BACK -SEE ARCHITECTURAL DETAILS. INSTALL BOTTOM OF LIGHT RAIL AT 9' -0" A.F.F. WITH CABLE SUSPENSION KIT AND STRAIGHT CABLE POWER SUPPLY OPTION - TYPES "B" AND "D" LIGHT FIXTURES TO BE MOUNTED IN THE LIGHT RAIL PER MANUFACTURER'S STANDARD CATALOG OPTIONS AND DETAILS - SEE ARCHITECTURAL PLANS FOR DETAILS. INSTALL BOTTOM OF SHADE AT 6' -6" A.F.F. - SUSPENDED PENDANT FIXTURE SHALL BE INSTALLED ON SUSPENDED LIGHT RAIL SYSTEM PER MAUFACTURER'S STANDARD CATALOG OPTIONS AND DETIALS - SEE ARCHITECTURAL PLANS FOR DETAILS. LIGHT FIXTURE & LAMP TO BE FURNISHED BY HOOD MANUFACTURER - G.C. TO VERIFY. 120V AUTO TIME SWITCH T / -1 $ 1 0 (0 -2 HRS OVERRIDE) LIGHTING CON ACTOR PANEL "A "—II— LTG LIGHTING CONTROL WIRING DIAGRAM JP LEVEL 3) , T /C: AUTO TIME SWITCH SHALL BE #EW101 OR EQUAL. C: LIGHTING CONTACTOR, 120V COIL, 30A POLE, NO. OF POLE AS REQUIRED. LIGHTING CONTACTOR SHALL BE SQUARE -D "LG" SERIES OR EQUAL. WAS ING (E) STORAGE ( N.I.C. ) MALL S ( N.I , • , AIRS C. ) VOID SPACE ( WALK IN-- FREEZER EXIT/ SERVICE NORTH (E) MALL EXIT/ SERVICE COR i A :117- ////. 1 / .r ?A 5d �"" ~ 5d__"' 5d ' 5d 1 (E) MALL COMMON AREA { - {O KEY NOTES O VIA LIGHTING CONTACTOR. PROVIDE ADDTIONAL CONDUCTORS FOR EMERGENCY LIGHTING AND EXIT SIGN. 2U Or-2 HOURS TIME SWITCH FOR LIGHTING OVERRIDE. . 3) WALK IU COOLER REGISTER PICK UP LIGHTING PLAN SCALE: 1 /4 " =1' -0 " - - - -- r_ CZ MANAGER'S STATION REVIEWED CODE COMPLIANCE NEPA JAN - 221Jt18 City Of Tukwila BUI .DIN M :ION ECER/Et CITY OF TI NOV 2 8 2007 1► PANDA RESTAURANT GROUP INC, 1683 Walnut Grove Ave. Rosemead, California 91770 Telephone: 626.1 .g8a8 Facs lm i le : 626.372.8288 All ideas, designs, arrangement and plans Indicated or represented by this drawing are the property of Panda Express Inc. and were created for use on this specific project. None of these ideas, designs, arrangements or plans may be used by or disclosed to any person, firm, or corporation without the written permission of Panda Express Inc. REVISIONS: A XXXXX A A A A A ISSUE DATE: 15T 1ST SUBMIT DRAVVN BY: PANDA PROJECT #: M1- 08 -D1189 HYC PROJECT #: CPC0719 ARCHITECT : XX -XX -XX 1683 WALNUT GROVE AVE., SUITE #301 ROSEMEAD, CA 91770 TEL: 626.280.9188 FAX: 626.280.9189 E -MAIL: INFO @CALARC.NET PANDA EXPRESS WESTFIELD SOUTHCENTER SPACE NO. FC -10 633 SOUTHCENTER PKWY., TUKWILA, WA 98188 E -1.1 LIGHTING PLAN Z: \Cal Arc ProJect107 Project -CAL Arc107 -1 PX construction documant\170705 PX Q South Center Mall, Tukwila, WA M1 -08 -01189 MEP Only( Omit)\1 70 705R1\Electrical\M17D133E.dwg, 11/13/2007 7:01:37 PM, Oce TDS400 1.x.pc3 3/4' DIA. CONDUIT - OILY, PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR EXTEND CONDUIT, INSIDE WALL, TO ABOVE ACCESSIBLE CEILING SPACE PROVIDE 4' OCTAGONAL JUNCTION BOX WITH SCREW THREADS SET AT 11-E 2 + 8 O'CLOCK POSITIONS FEwfoTE FEE PULL STATION. CABLE, AND ANY OTNEFi MEICELLAINEOUS EOUIPMENT SHALL BE PROVIDED BY OTHERS ANSUL PULL STATION DETAIL SCALE: NO SCALE -- - �- HOME RUN TO PANEL. CIRCUIT NUMBERS, PHASE, NEUTRAL AND GROUND 5 3 1 CONDUCTORS INDICATED. ALL CONDUCTORS TO BE #12 EXCEPT WHERE NOTED. PARTIAL CIRCUIT CONDUIT INSTALLED CONCEALED ABOVE CEILING OR IN WALL - — — — — - CONDUIT INSTALLED CONCEALED BELOW FLOOR SLAB OR UNDERGROUND FLUORESCENT LIGHT FIXTURE TRACK LIGHT FIXTURE 1 0 1 NF A.F.F. NL WP +12" RECESSED LIGHT FIXTURE EXIT LIGHT, MOUNT +7' -6" OR AS NOTED EMERGENCY BATTERY UNIT WITH HEADS, TOP OF UNIT TO BE 6" BELOW CEILING SINGLE POLE SWITCH, +3' -10" OR AS NOTED (PL= SWITCH W/ PILOT LIGHT) 20 AMP DUPLEX RECEPTACLE, +18" OR AS NOTED FOURPLEX RECEPTACLE, +18" OR AS NOTED JUNCTION BOX TELEPHONE OUTLET, +18" W/ 1/2" CONDUIT TO ABOVE CEILING DISCONNECT SWITCH, (PROVIDED BY ELECTRICAL CONTRACTOR) DISCONNECT SWITCH FURNISHED WITH EQUIPMENT.(INSTALLED BY ELECTRICAL CONTRACTOR) MOTOR CONNECTION PANELBOARD, TOP 6' -0" DROP CORD RECEPTACLE SOLENOID VALVE - FURNISHED & INSTALLED BY OTHERS, E.C. TO MAKE ALL FINAL CONNECTIONS. NON -FUSED ABOVE FINISHED FLOOR NIGHT LIGHT (NON- SWITCHED FIXTURE) WEATHERPROOF HEIGHT ABOVE FLOOR TO CENTER LINE OF OUTLET BOX • ELECTRICAL SYMBOLS LEGEND SCALE: NO SCALE t THIS INSTALLATION SHALL COMELY WRH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE, APPUCABLE SECTIONS OF OTHER NFPA, OSHA, LFE SAFETY CODES AND RECOMMENDATIONS, AND THE INTERIM AMENDMENTS, 2. THIS CONTRACTOR SHALL DO ALL ALTERATIONS AND REWORK INDICATED AND /OR REOUEED FOR THE PROPER INSTALLATION AND OPERATION OF ALL EXISTING ELECTRICAL SYSTEMS, INTEGRATING THE NEW AND EASING AREAS. a ALL CONDUIT INSTALLED INDOORS TO BE ELECTRICAL METAWC TUBING MT) MNNEMUM 3/4" OR AS NOTED OTHERWISE. ALL WIRE MUST BE COPPER WITH 600 VOLT INSULATION. MNNEMUM WIRE SQE IS #12. ALL WERE OF ANY TYPE MUST BE RUIN N CONDUIT. ROMEX AND BX CABLE ARE NOT PERMITTED. MC OR FLEXBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS, NOT EXCEEDING 4 FEET. PVC IS NOT PERMITTED. 4. CONDUCTORS INSTALLED INDOORS, *10 AVM AND SMALLER, TO BE SOLD, COPPER, TYPE "THIN" (hW»A 812). CONDUCTORS #8 AND LARGER TO BE TYPE "THWN ", STRANDED, COPPER. 5. MINT SWITCHES TO BE 20 AM' EQUAL TO HUBBELL 4081201 WITH STAINLESS STS PLATE=S. RECEPTACLES TO BE 120 VOLT, 20 AMP EQUAL TO HUBBELL #5362 WITH STAINLESS STEEL. PLATES. 6. REFER TO ARCHITECTURAL FERECTID CE LRNIG PLAN FOR EXACT PLACEMENT OF UGHT FIXTURES AND ANY OTHER EOUIPMENT INSTALLED N ca NG SYSTEM. 7. ELECTRICAL CONTRACTOR TO RED D VEII Y ALL EASING CONDITIONS PRIOR TO BIDDING. 8. ELECTRICAL CONTRACTOR TO PROVIDE TEMPORARY E ECTPoCAL POWER AS FEOUIRED FOR CONSTRUCTION. 9. ELECTRICAL PANG TO BE PANELBOARD CONSTRUCTION EQUAL TO SQUARE "D" WITH BOLT-IN BREAKERS. ALL PANELS, DISCONNECTS + CONTROLS SHALL BE FULLY CENTFED + LABELED. ED, PROVIDE ELECTRICAL PANELS WITH A COMPLETE PANEL SCHEDULE WHCH B FU LY TYPED AND N PROTECTIVE PLASTIC SLEEVNG. ACCEPTABLE MANUFACTURERS FOR SWITCHGEAR, PANELS + MOTOR CONTROLS INCLUDE= CUTLER HAMMER, GE, SOUAFE -D, OR EQUAL 1a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la ELECTRICAL CONDUIT CONNECTION MIDST BE COMPRESSION TYPE UNLESS USING MC OR HEAVY WALL CONDUIT WHERE SCREW TYPE CONNECTORS ARE PERMITTED. ELECTRICAL SPECIFICATIONS SCALE: NO SCALE 45KVA X'MER 480V/120 -208V 30, 4W Isc =2312A 1 2 200A -3P (E) L =±20' VD =NEG. "A" PANEL 10KAIC WO' VD =NEG. -3P SHORT CIRCUIT DUTY NOTES: MAIN BREAKER AT PANEL "H" BKR TYPE "KC" BY "SQUARE -D" (200A MAX.) _()_ 2000A 2774480V 30 4W BUS 70A -3P (() " 2 PANEL -3P NOTE: 1. ALL NEW CIRCUIT BREAKERS SHALL MATCH EXISTING. L =450' VD=1.9% SINGLE LINE DIAGRAM SCALE: NO SCALE --L 2000A 277/480V, 30, 4W < < a ISC= 65000A MAX. 2. ALL WIRING SHALL BE COLOR -CODED AS FOLLOWS; 208/120V SYSTEMS 480/277V SYSTEMS PHASE A - BLACK PHASE A - BROWN PHASE B - RED PHASE B - ORANGE PHASE C - BLUE PHASE C - YELLOW NEUTRAL - WHITE NEUTRAL - WHITE W/ TRACER OR GRAY COLOR -CODE SHALL IDENTIFY THE SAME PHASE THROUGHOUT THE SYSTEM, FROM SERVICE SWITCH OR TRANSFORMER THOUGH ALL BRANCH CIRCUITRY. 3. VERIFY EXISTING ELECTRICAL CONDITIONS IN FIELD / ALL UPGRADES REQUIRED BY CODE, LANDLORD, OR TENANT AT TENANT'S EXPENSE. - GRD. MAY USE THE CONDUIT & ITS CONDUCTOR W U.L. LISTED AS A GROUNDING CONDUCTOR. - ALL EQUIP. INSTALLED SHALL BE LISTED /LABELED BY AN APPROVED AGENCY. 1,01- 423 THE MAXIMUM AVAILABLE FAULT CURRENT AT EXISTING SWITCHBOARD IS 65,000 A MAX. SERIES RATED CIRCUIT BREAKER - PROVIDE MARKING IN ACCORDANCE WITH NEC SECTION 110 -22, MARKING SHALL READ "CAUTION - SERIES RATED SYSTEM =GO. GO. AMPS AVAILABLE. IDENTIFIED REPLACEMENT COMPONENT REQUIRED." DISTRIBUTION BREAKERS SHALL PROTECT ALL DOWNSTREAM PANELBOARD BREAKERS. SERIES RATED CIRCUIT BREAKER SHALL BE AS FOLLOWING OR EQUAL : BRANCH BREAKER AT PANEL "H" BKR TYPE "EDB" BY "SQUARE -D" (15A - 100A) (E) SWBD "SWBD 2A" (E): EXISTING. FIELD TO VERIFY. FEEDER NOTES: (E) 2"C-4#3/0+1#6G, FIELD VERIFY. 2"C-4#3/0+1#6G, MATCH EXISTING. 1/2 "C - #6 TO BUILDING STEEL. 2 "C -4 #1 /0 THHN & 1 #6GRD 1 "C -3 #4 THHN & 1 #8 GRD. SERIES RATING 65,000 A CONE COMPLIANCE fPA7 -NEC City of 11.11( tl RECEIVED CITY of TUKWU.A NOV 2 8 2007 SINGLE LINE DIAGRAM SCALE: NO SCALE PANDA RESTAURANT GROUP INC. 1683 Walnut Grove Ave. Rosemead, California 91770 Telephone: 626 .111..18A18 Facs lm i l e : 626.372.8288 All ideas, designs, arrangement and plans indicated or represented by this drawing are the property of Panda Express Inc. and were created for use on this specific project. None of these ideas, designs, arrangements or plans may be used by or disclosed to any person, firm, or corporation without the written permission of Panda Express Inc. • REVISIONS: ISSUE DATE: DRAVVN BY: PANDA PROJECT #: M1- 08 -D1189 HYC PROJECT #: CPC0719 ARCHITECT : 1683 WALNUT GROVE AVE., SUITE #301 ROSEMEAD, CA 91770 TEL: 626280.9188 FAX: 626.280.9189 E -MAIL: INFO @CALARC.NET PANDA EXPRESS WESTFIELD SOUTHCENTER SPACE NO. FC -10 633 SOUTHCENTER PKWY., TUKWILA, WA 98188 E -2.0 GENERAL NOTES Z:1Cal Arc ProJecl107 ProJect -CAL Arc107.1 PX cancstruction document1170705 PX la South Center Moll, Tukwila, WA M l- 08-131139 MEP Only( Omit) 1170 705RP,EIedica11M17D133E.dw0, 11113!2007 7:02:52 PM, Ow TDS4001x.pc3