HomeMy WebLinkAboutPermit PG07-063 - DSW SHOESDSW SHOES
17100 SOUTHCENTER PY
PGO7-063
Parcel No.: 2623049081
Address:
Suite No:
City of Tukwila
17100 SOUTHCENTER PY TUKW
Tenant:
Name: DSW SHOES
Address: 17100 SOUTHCENTER PY , TUKWILA WA
Owner:
Name: WIG PROPERTIES LLC -SS
Address: 4811 134 PL SE , BELLEVUE WA
doc: UPC -10/06
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Contact Person:
Name: SARAH NIELSEN
Address: 1120 E 80 ST #211 , BLOOMINGTON MN
Contractor:
Name: PLUMBING EXPRESS INC
Address: 813 ACADEMY ST , SUMNER WA
Contractor License No: PLUMBEI98600
Plumbing
Bathtub or combination bath/shower
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic, with independent drain
Drinking fountain or water cooler (per head)
Food -waste grinder, commercial
Floor drain 2
Shower, single head trap 0
Lavatory 2
Wash fountain 0
Receptor, indirect waste
Sinks
Urinals
Water Closet
FIXTURE TYPE AND OUANTITY
* *continued on next page **
PLUMBING /GAS PIPING PERMIT
Permit Number:
Issue Date:
Permit Expires On:
Expiration Date: 09/20/2008
DESCRIPTION OF WORK:
NEW WATER HEATER, SANITARY LINE, AND COLD WATER LINE. FURNISH AND INSTALL WATER
HAMMER ARRESTERS, VENT THROUGH ROOF, AND GAS METER.
Phone:
Phone: 800 541 -0821
Phone: 253 8264621
Value of Plumbing /Gas Piping: $0.00 Uniform Plumbing Code Edition: 2003
Fees Collected: $278.50 International Fuel Gas Code Edition: 2003
Steven M Mullet, Mayor
Steve Lancaster, Director
PG07 -063
07/12/2007
01/08/2008
Plumbing (cont.)
0 Building sewer and each trailer park sewer
0 Rain water system - per drain (inside bldg)
0 Water heater and/or vent
0 Industrial waste treatment interceptor, including
0 its trap and vent, except for kitchen type
2 grease interceptors
0 Repair or alteration of water piping and/or water
treatment equipment
Repair or alteration of drainage or vent piping
Medical gas piping system serving (1 -5)
inlets /outlets for a specific gas
0 Medical gas piping (6 +) inlets /outlets
2 Gas Piping
1 Gas piping outlets (0 -5)
3 Gas piping outlets (6 +)
1
0
1
0
0
0
0
0
0
0
PG07 -063 Printed: 07 -12 -2007
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Permit Number: PGO7 -063
Issue Date: 07/12/2007
Permit Expires On: 01/08/2008
Permit Center Authorized Signature: Date: o'1 X21
ex a�
d wi
The granting of this permit does not proms
construction or the • erformance of wor
•
I
d
e
I hereby certify that I have read an
governing this work will be compli
Signature:
Print Nam
doc: UPC -10/06
Steven M Mullet, Mayor
Steve Lancaster, Director
' s permit and know the same to be true and correct. All provisions of law and ordinances
er specified herein or not.
e to give authority to violate or cancel the provisions of any other state or local laws regulating
uthorized to sign and obtain this plumbing /gas piping permit.
Date:l ,/ a "C
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PG07 -063 Printed: 07 -12 -2007
Parcel No.: 2623049081
Address:
Suite No:
Tenant:
doc: Cond -10/06
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
17100 SOUTHCENTER PY TUKW
DSW SHOES
1: ** *PLUMBING AND GAS PIPING * **
PERMIT CONDITIONS
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
8: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R-3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to
twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill,
frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
* *continued on next page **
Permit Number:
Status:
Applied Date:
Issue Date:
PG07 -063
ISSUED
03/14/2007
07/12/2007
PG07 -063 Printed: 07 -12 -2007
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work
construction or the performance of work.
doc: Cond -10/06 PG07 -063
Date: "/ a —0 7
ordinances governing
or local laws regulating
Printed: 07 -12 -2007
s
SITE LOCATION
Site Address: r i On. r 5..&u.n
Tenant Name: f`,SuJ
Property Owners Name: V.hc\ at t*% eS
Mailing Address: '4' \ 13 PeMeAty \NIA A44
City
CONTACT PERSON - who do we contact when your permit is ready to be issued
Name: SxrrOn Kie \ er Day Telephone: ( gZ0 1-OSZ\
Mailing Address: 112o eck9tt Row. sweer. way, ckectAr tb ltl, IAN Sg#2.c
City State
E -Mail Address:QCbraV oktia r C3b1M
GENERAL CONTRACTOR INFORMATION -
(Contractor Information for Mechanica ( pg 4 ) for Plumbing and Gas Piping (pg 5))
Company Name: T. 6 .
Mailing Address:
CITY OF TUKWIP
Community Developiit Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
hqx//www.ci.tukwila.wa.us
Contact Person:
E -Mail Address:
Contractor Registration Number:
Building Perms, No.
Mechanical Permit No. O 1
Plumbing/Gas Permit No. etrOdA'-ilr
Public Works Permit No.
Project No.
?(2
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
King Co Assessor's Tax No.: 21/1-
Suite Number: Floor: 1
New Tenant: _yf, Yes ❑ ..No
State
Fax Number: gSZ15 4- q
State
Zip
Zip
Zip
City
Day Telephone:
Fax Number:
Expiration Date:
ARCHITECT OF RECORD -Ali plans must be wet stamp by Architect of Record
Company Name: once '1 rbC.t. p vrAnk-Vt' r % , 11r1C..
Mailing Address:(ot b eno,A, V Ae.vg OK 43Cel
City State Zip
Contact Person: Mike AnMit Day Telephone: (alai-1545 45Sb
E -Mail Address:m r k .corn Fax Number: ( t-% JS4S - LISSS
ENGINEER OF RECORD -Ail plans must be wet stamped by Engineer of Recor
Company Name:SWIZ NASNC1CCk EnlirWPY1vn, arc .
Mailing Address: &t?d? *ki S& lct rt m A Weskez PiV\e., cock 1 4SfYin
City State
Day Telephone:(, 4 Isms. 4s t
Fax Number: GI 4 1545 - 455
Contact Person: eee.ce a b.* 22C"
E -Mail Address9 1 ,L '�CCo� c1n Yet rbr�. CGytYI
Q:Mpplications\Ponns- Applications On Line\3 -2006 - Permit Appliatioadoc
Revised: 9 -2006
bb
Zip
Page 1 of 6
BUILDING PERMIT INFORMATION — 206431 -3670
Valuation of Project (contractor's bid price : $ SW OW
Scope of Work (please provide detailed information): tnt. cervv-AP \ e.4ck -ktr- t ce_kcaa\ ink -
-M•tP iY% eccc iY' c rvyn{ac rN y- k s J 94CNGe. "
Will there be new rack storage? ® Yes ❑.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
1 ° Floor
2 Floor
Floor
Floors thru
Basement
,Accessory Structure'°_
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck ;
ITncovered Deck
(to, cl - iS
lntenor Remodel
Addition to
Existing
Structure
Type of
Construction per
IBC
Type of
Occupancy per
IBC
M
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes O No If `yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
• Sprinklers • Automatic Fire Alarm
Existing Ba ing Valuation: $
❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes MI No
If "yes', attach list of materials and storage locations on a separate 8 x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System - For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
Q: Applications \Forms- Applications On Line \3 -2006 - Permit Application.doc
Revised: 9-2006
bh
Page 2 of 6
Fixture Type:
Qty
Fixture Type: > ;
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Bathtub or combination
bath/shower
Drinking fountain or water
cooler (per head)
Z
Wash fountain
Gas piping outlets
Bidet
Food -waste grinder,
commercial
Receptor, indirect
waste
Clothes washer, domestic
Floor drain
Z
Sinks
Dental unit, cuspidor
Shower, single head trap
Urinals
1
Dishwasher, domestic,
with independent drain
Lavatory
Z
Water Closet
3
Building sewer or trailer
park sewer
Rain water system — per
drain (inside building)
Water heater and/or
vent
,
medical gas
inlets/outlets — six or more
Industrial waste
pretreatment interceptor,
including its trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of water
piping and/or water treating
equipment
Repair or alteration
of drainage or vent
piping
Medical gas piping system
serving one to five
inlets /outlets for specific gas
PLUMBING AND GAS PIPIN) ERNIIT INFORMATION - 206 -431, ;70
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name: — r". 6 . D .
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Plumbing work (contractor's bid price): $ U t dt/11
Valuation of Gas Piping work (contractor's bid price): $
Scope of Work (please provide detailed information): _bistu l ao.lismailamfivaS=1"tfne...ACZIA.Y2a_Antea-ASS-,--netA-1---
Wa{ts tM�{2C, COaNikram t tr a CtA t. ketr Rxmis1n ' ''C to t ircovwner
arc Ver k- VAX c 4 - t ¥S .t .
Building Use (per Int'l Building Code):
Occupancy (per Int'1 Building Code): M
Utility Purveyor: Water: Sewer:
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Q: Applications\Fomo- Appliations On linel3 -2006 - Permit Application.doc
Revised 9-2006
bb
Page 5 of 6
PERMIT APPLICATION NOT
Applicable to all permits in this apaton
Signature:
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
Date Application Accepted:
BUILDING OWNER OR AUTHORZEO AGENT:
Print Name: Tim Sc3rrer%V.-
Obi ILI 1
Q:Wpplications\Fotn s- Applications On Line\3 -2006 - Permit Application.doc
Revised: 9 -2006
bh
Date: 3 help/
Day Telephone: 'Rob 1 S4 -I -OR Z\
Mailing Address: MO EaSk 'EOM SviceeC- AZt", Rocoh:vvcikon, IAN SSA-72)
City
State
Staff Initials:
Zip
Date Application Expires:
Page 6 of 6
Doc: RECSETS-06
RECEIPT NO: R07 -00358
Initials: JEM
User ID: 1165
Payee: ELDER -JONES
SET ID: S000000706 SET NAME: Tmp set/Initialized Activities
SET TRANSACTIONS:
Set Member Amount
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http:/lwww.citukwila.wa.us
D07 -084 2,727.70
M07 -049 150.46
PG07 -063 49.50
TOTAL: 2,927.66
TRANSACTION LIST:
Type Method Description Amount
Payment Check 48382
ACCOUNT ITEM LIST:
Description
PLAN CHECK - NONRES
SET RECEIPT
TOTAL:
Payment Date: 03/14/2007
Total Payment: 2,927.66
2,927.66
2,927.66
Account Code Current Pmts
000/345.830 2,927.66
TOTAL: 2,927.66
Receipt No.: R07 -01372
Initials: JEM
User ID: 1165
Payee: PLUMBING EXPRESS INC.
ACCOUNT ITEM LIST:
Description
PLUMBING - NONRES
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: //www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 2623049081 Permit Number: PG07 -063
Address: 17100 SOUTHCENTER PY TUKW Status: APPROVED
Suite No: Applied Date: 03/14/2007
Applicant: DSW SHOES Issue Date:
TRANSACTION LIST:
Type Method Description Amount
Payment Check 6801 229.00
Account Code Current Pmts
000/322.100 229.00
Total: $229.00
Payment Amount: 5229.00
Payment Date: 07/12/2007 12:42 PM
Balance: $0.00
0267 07/13 9710 TOTAL 229.00
doc: Receiot -06 Printed: 07 -12 -2007
COMMENTS:
� /
P nl gii / / L 0 -rc>,94‘4‘ 7
/1/4)2 F' " COItI ,/ it,c // /'k., -
Ad4ress:
/ 06 � y nr lhc ,
i
Special Instructions:
ate W ted: /
Requester:
Phone No:
- a /0 -3y7-
0.5 - 4
Project /' , ��� j
[itJ
Type of l -
L v
rite sit
Ad4ress:
/ 06 � y nr lhc ,
ate Called:
Special Instructions:
ate W ted: /
Requester:
Phone No:
- a /0 -3y7-
0.5 - 4
INSPECT I a N NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
Inspect
Approved per applicable codes.
Receipt No.:
/iti74ug
$58.00 REINSPECTION FEE REQUIRED. fSrior to inspection, fee must be
aid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
'Date:
(206)431 -3
El Corrections required prior to approval.
I V
Project:
0s 60 SydFS
Type of I pection:
d >r; f2 — / />J r' /, -.i
Address:
/7/62e) Sdvi cAl- i iip
_
ate Called: FaoV o5�-
g� `�
Special Instructions:
Date Wanted:
7- 3 0- O7
C a.m.,
p.m.
Requester:
Phone No:
c:2 53— 2,5 o - /0
Lam_ �! --
z
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
'Inspect
�
INSPECTION RECORD
Retain a copy with permit
(206)431 -36
pproved per applicable codes. El Corrections required prior to approval.
COMMENTS:
IA
I
58.00 REINSP ` ION FEE REQUIRED. Prior to inspection, fee must be
outhcenter Blvd.. Suite 100. Call the schedule reinspection.
paid at 630
(Receipt No.: 'Date:
Pr ct:
_57-1 e..)
Type of Inspection:
yam„
6 Cr��
Address:
/7 / o d - 50,- /h /
Date Called:
Special Instructions:
Date Wanted:
�a ��
m.
2 /2
7
Requester:
Phone No:
.7,25 3 -, z .57)
— /° Y v
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Sou thcenter Blvd., #1 00, Tukwila, WA 98188
OMMENTS:
pproved per applicable codes. Corrections required prior to approval.
.00 REINSF CTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection.
'Receipt No.:
Date:
(206)431 -3670
LL
7
ACTIVITY NUMBER: PG07 -063 DATE: 03 -14 -07
PROJECT NAME: DSW SHOES
SITE ADDRESS: 17100 SOUTHCENTER PY
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Issued
DEPARTMENTS: +3'01
( 56 Buil•i Division
Publi Works
Complete
Comments:
Documents/routing slip.doc
2 -28-02
PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
Fire Prevention
Structural
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Incomplete n
Planning Division
❑ Permit Coordinator
TUES/THURS ROUTING:
Please Route Structural Review Required ❑ No further Review Required
DATE:
DATE:
DUE DATE: 03-1507
Not Applicable ❑
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
El
DUE DATE: 04-12-07
Approved ❑ Approved with Conditions Not Approved (attach comments) n
Notation:
REVIEWER'S INITIALS:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
License Information
License
PLUMBEI98600
Licensee Name
PLUMBING EXPRESS INC
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
602226682
Ind. Ins. Account Id
VICE PRESIDENT
Business Type
CORPORATION
Address 1
813 ACADEMY ST
Address 2
.
City
SUMNER
County
PIERCE
State
WA
Zip
98390
Phone
2538264621
Status
ACTIVE
Specialty 1
PLUMBING
Specialty 2
UNUSED
Effective Date
9/20/2002
Expiration Date
9/20/2008
Suspend Date
Separation Date
Parent Company
Previous License
PLUMBE *077PR
Next License
Associated License
Business Owner Information
Name
Role
Effective Date
Expiration Date
KILDARE, JOHN T
PRESIDENT
09/20/2002
Bond
Amount
KILDARE, KRISTI
VICE PRESIDENT
09/20/2002
Bond Information
Bond
Bond
Company
Name
Bond Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
GREAT
AMER
INS CO
Until
.
Look Up a Contractor, Electric; qn or Plumber License Detail Page 1 of 2
Washington State Department of Labor and Industries
General/Specialty Contractor
A business registered as a construction contractor with L&I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
https:// fortress .wa.gov /lni/bbip /printer.aspx ?License= PLUMBEI98600 07/12/2007
TYP.
- - - - -- - - - - - -- -
n
B
Pty
RTU -3
240,000 BTUII
1 GAS INPUT I
EE ROOF MOUNT PIPE
UPP+OR DETAIL, TYP.
I -I /4'
ON ROOF, TYP.
L
1 -1/2'
1 -1/4'
r s=j - •
0
PILE
Permit Na
0
0
P
,‘
nark reliefs nomad mad Es subject b anus and ambito *
yp oal cf oors rucoon dOOMOMIS &es Plot 'Wynn
It1e tiotaccn cf eat aaoepaed code or ' Raoul
Vied
7- gc3
Qy of Tukwila
BUILDING DIVISION
•
3
12 )
FOCAL_ 16
RTU_8
78,000 STUN
GAS INPUT
2'
r-- -CW ON - ROOt•<TYP .
3/4'
PLUMBING PLAN
118 =1'-O
I'
SEE ROOF MOUNT PIPE
SUPPORT DET IL, TYP.
ON
ROOF, TYP.
j
E El
SEPARATE PERMIT
REQUIRED FOR
iNedlanical
liBectriral
O Plumbing
a
Qs Plpiry
City of Tukwila
BUILDING Ds VISION
2'
RUN AS HIGH
AS POSSIBLE
2 -1/2'
3/4'
I Th-2
240,000 BTU&
I GAS INPUT I
REGULATOR BY PC,
COORDINATE WITH HVAC
CONTRACTOR FOR UNIT
REQUIREMENTS, SEE
GAS RISER DIAGRAM,
TYP.
240,000 STUN
'GAS INPUT I
13/4' 1
1
3/4' 14B
3/4' VERTICAL CW
LINE I5 TO BE
IMULATED
-e?
3/4'
0
-
r
Co
ON ROOF, TYP.
r , .0
RTU -6
18,000 B TUN
GAS INPI T
RBELSIQNS
I f'a d1.'-,g shwa be made to the sccr-:
- ..-: without gror pr :! c `
,.:: , C:. CW. : — n.
t: :a v... ice_• ai r..�: /,f_ i -- .!:i
C` ! C-
i
:.�
•
'P?
2 -1/2'
7 G
-1 1. [ L - 7
t•
L
3/4' HB
TOP G ROOF
STRUCTURE
3/4' VERTICAL CH
LINE IS TO BE
EXPOSED
5TA »NLESS STEEL
SCRE4 (TYP.)
SCALE: NTS
GENERAL NOTES
I. THERE ARE NO FIRE RATED INTERIOR PARTITIONS IN THIS FLOOR
PLAN. IF A BUILDING HA5 FIRE RATED INTERIOR PARTITIONS, ALL PIPE
PENETRATIONS THRU RATED PARTITIONS ARE TO BE PROPERLY
SEALED WITH FIRE STOPPING TO MEET APPLICABLE U.L.
PARTITION LISTINGS AND DETAILS.
2. UNLESS OTHERWISE SPECIFIED, CONTRACTOR SHALL PROVIDE ALL
NECESSARY EQUIPMENT, MATERIAL, LABOR AND SUPERVISION NECESSARY
TO COMPLETE THE PLUMBING WORK IN ACCORDANCE WITH THE
SPECIFICATIONS AND STANDARDS.
3. ALL MATERIAL SHALL BE NEW AND OF COMMERCIAL GRADE, AND BEAR
UNDERWRITER'S LABORATORIES AND UNION LABELS WHERE SUCH LABELING
APPLIES.
4. PLUMBING CONTRACTOR TO FIELD VERIFY SLOPE AND ELEVATION OF
EXISTING SEWER PRIOR TO ANY NEW PLUMBING INSTALLATION.
5. PLUMBING CONTRACTOR MUST VISIT THE JOBSITE TO BECOME FAMILIAR
WITH MAJOR ITEMS SUCH AS STRUCTURAL ELEMENTS AND OTHER
EXISTING JOB CONDITIONS THAT MAY AFFECT THE WORK. ADDITIONALLY,
PLUMBING CONTRACTOR SHALL VERIFY EXACT LOCATIONS AND
DIMENSIONS OF SUCH ITEMS AS WASTE, VENTS, WATER LINES, ETC.
6. SPRINKLER CONTRACTOR SHALL MODIFY SPRINKLER HEADS FOR NEW
TENANT LAYOUT. RUN HYDRAULIC CALCULATIONS AS REQUIRED. SEE
SPECS. DESIGN NEW LAYOUT TO MEET NFPA 13 AND LOCAL AUTHORITY
HAVING JURISDICTION AND LANDLORD'S REQUIREMENTS.
( 2 )
CODED NOTES
1' NATURAL GAS LINE DOWN THRU THE ROOF TO THE UNIT HEATER.
PROVIDE REQUIRED WEATHERPROOF PIPE CURB.
LOCATE THE DOMESTIC WATER HEATER ON DRAIN PAN MOUNTED ON A
SHELVING ASSEMBLY ABOVE THE JANITORS RECEPTOR. THE MOUNTING
ASSEMBLY SHALL BE LOCATED HIGHER THAN 6' ABOVE MOP SINK.
ROUTE DRAIN LINE TO MOP SINK. SEE RISER DIAGRAM AND PLUMBING
FIXTURE SCHEDULE ON SHEET P5.I FOR REQUIREMENTS.
CONNECT NEW SANITARY LINE INTO THE LANDLORD'S EXISTING
SANITARY SERVICE IN THIS AREA. FIELD VERIFY EXACT LOCATION
AND SIZE OF LANDLORD'S MAIN PRIOR TO BIDDING. INSTALL A
DOUBLE CLEAN OUT AT CONNECTION TO LANDLORD'S MAIN.
REFER TO STACK DIAGRAM AND PLUMBING SPECIFICATIONS FOR
FURTHER INFORMATION. FIELD VERIFY EXACT LOCATION OF
SANITARY CONNECTION PRIOR TO BID.
CONNECT NEW COLD WATER LINE INTO THE EXISTING COLD
WATER TAP IN THIS AREA. REFER TO RISER DIAGRAM AND
PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION. FIELD
VERIFY EXACT LOCATION Of LANDLORD'S DOMESTIC COLD WATER
PIPE PRIOR TO BID.
PROVIDE WATER SUB -METER WITH A REMOTE READER PER
LANDLORD'S AND WATER COMPANY REQUIREMENTS. REMOTE
READER TO BE INSTALLED IN LANDLORD ELECTRICAL ROOM.
FIELD VERIFY EXACT LOCATION AND REQUIREMENTS.
NIA: FURNISH AND INSTALL WATER HAMMER ARRESTERS IN THE
DOMESTIC COLD AND 140T WATER PIPING AS SHOWN ON THE
WATER RISER DIAGRAM AND AS REQUIRED BY CODE. WATER
HAMMER ARRESTERS TO BE LOCATED IN AN ACCESSIBLE
LOCATION. UNITS AS MANUFACTURED BY SIOUX OR PRECISION
PLUMBING PRODUCTS ARE ACCEPTABLE.
VTR: VENT TO BE EXTENDED THROUGH ROOF. OFFSET 2' -O AND
TERMINATE WITH 3' VENT THROUGH ROOF. CONTRACTOR IS TO
MAINTAIN 10' -0' MINIMUM CLEARANCE FROM ALL INTAKE HOODS.
REFER TO STACK DIAGRAM AND PLUMBING SPECIFICATIONS FOR
FURTHER INFORMATION.
INSTALL 1/2' COLD WATER PIPE FROM TRAP PRIMER DONN IN
WALL UNDER LAVATORY TO FLOOR DRAIN. LOCATE TRAP PRIMER
UNDER THE LAVATORY. TRAP PRIMER TO BE LOCATED IN AN
ACCESSIBLE LOCATION.
ALL PLUMBING FIXTURES SHALL BE INSTALLED WITH STOP
VALVES TO ISOLATE EACH FIXTURE.
SPRINKLER CONTRACTOR TO MODIFY EXISTING SPRINKLER
SYSTEM FOR NEW BUILDING LAYOUT. CONTRACTOR SHALL REUSE
AS MUCH AS POSSIBLE FROM THE EXISTING SPRINKLER SYSTEM
AND ALARM SYSTEM. COORDINATE WITH LANDLORD. SEE
REFLECTED CEILING PLAN FOR HEAD LAYOUT. FIRE PROTECTION
CONTRACTOR TO DETERMINE ACTUAL AMOUNT AND LOCATION OF
HEADS. COORDINATE WITH LANDLORD AND TENANT. FIRE
PROTECTION WATER SERVICE SIZE TO BE DETERMINED BY FIRE
PROTECTION CONTRACTOR BY HYDRAULIC CALCULATIONS PRIOR
TO START OF WORK AS REQUIRED. FLOW 4 TAMPER SWITCHES
TO BE PROVIDED, INSTALLED, AND WIRED BY FIRE PROTECTION
CONTRACTOR AT EACH TENANT SPACE AS REQUIRED. VERIFY
EXACT REQUIREMENTS PRIOR TO START OF 1'IORK
PLUMBING CONTRACTOR TO PROVIDE GAS METER AND
REGULATOR PER LOCAL GAS COMPANY REQUIREMENTS.
COORDINATE WITH LOCAL GAS COMPANY FOR METER AND
REGULATOR STANDARDS PRIOR TO ROUGH -IN. COORDINATE ALL
REQUIREMENTS WITH LANDLORD. FIELD VERIFY THE EXISTING
LOCATION AND REQUIREMENTS.
INSTALL GAS CONNECTIONS TO EQUIPMENT PER MANUFACTURERS
RECOMMENDATIONS. PROVIDE PRESSURE REDUCING VALVE AS
REQUIRED, UNION, SHUT -OFF VALVE AND DIRT LEG PRIOR TO
COIF 4ECTION Or' EACH UNIT. ALL PIPING TO BE SCHEDULE 40
BLACK IRON. TRANSITION AS REQUIRED TO UNIT GAS
CONNECTION.
FREEZE PROOF 1405E BIBB IS TO BE ZURN Z -1310 WITH INTEGRAL
VACUUM BREAKER.
PIPE - PANT 1011TH
TWO COATS OF RUST
lN1IiSiTING PAINT IF
NOT INSULATED
ALUM NUM PIPE STRAP
PIPE CRADLE
RUBBER TRAFFIC PAD. RE+ CFIE STONE
BALLAST 8ELOI1 IF PRESENT
BOTTOM OF ROOF S i RuCTLRE
ROOF MOUNTED PIPE SUPPORT DETAIL
EEC` :
CITY 0= iKv
r.AR 1
ThO:ECkQ2,
z
0
co
QC
1
P1.!
O
cti
ra
ralA
b
V
0
�
co fl
0)
A b
m s
0
W
H
o
me Nov= mourn at eeromen.Trat
(MOM rat =E Cs neirfung eater
0 9mii$i44T
sar man rot urns
s IECPCLOCa- c.sas=ea •4•00*
SEW. acs111,11iwc:lE84:1Mr+.RO •
MEM SIMMKONE aaa® IESIOD Wern
a-
1-
CO
z
SAI E 07E4
DRAWING NUWBEFt
1
•
RTU -7
78,000 BTU-1
GAS INPUT
is
RTU -3
240,000 BTIJ•I
GAS INPUT
•
I -1/2'
RTU -5
125, 000 STUN
GAS INPUT
1 - 1/4'
2'
•
RT -4
240,000 BTUH
GAS INPUT
I -1/4'
1 - 1/4'
•
GAS PIPING DETAIL
SCALE: N
' -'/4'
PLUMBING ABBREVIATIONS
AB. ABOVE
AFF. ABOVE FINISHED FLOOR
ARCH. ARCHITECT
BEL. BELOW
BLDG. BUILDING
CLG. CEILING
CO CL EAN OUT
CONT. CONTINUAT
CW COLD WATER
CONTR. CON
COLOD. COORDINATE
DCO DOUBLE CLEAN OUT
DISC. DISCONNECT
DN. DOWN
EA. EACH
EC. ELECTRICAL
CONTRACTOR
EX. EXISTING
EWC ELECTRIC WATER
COOLER
FCO FLOOR CLEAN OUT
FD FLOOR DRAIN
FIXT. FIXTURE
FLR. FLOOR
FPC. FIRE PROTECTION
CONTRACTOR
FURN. FURNISH
F FLUSH VALVE
G GAS
GAL. GAL
GC. GENERAL
CONTRACTOR
GPH. GALLONS PER
HOUR
2 -1/2'
GAS METER,
COORDINATE LOCATION
W/ LANDLORD
GAS SERVICE
FROM MAIN.
2 -1/2'
RTU -6
78,000 BTUN
GAS INPUT
RTU-O
78,000 BTUH
GAS INPUT
1 -1/4'
RTU -2
240,000 BTUH
GAS INPUT
GPM. GALLONS PER
MINUTE
148. 1405E BIBB
I4C. HEATING
CONTRACTOR
HP. HORSEPOWER
NW HOT WATER
14 W HOT WATER
RETURN
INV. INVERT
LAV LAVATORY
MAX. MAXI
MFR. MANUFACTURER
MT. MOUNT
NTS. NOT TO SCALE
PC. PLUMBING
CONTRACTOR
PLBG. PLUMBING
RD ROOF DRAIN
RTU ROOFTOP UNIT
SAN SANITARY
5S. SERVICE SINK
TYP. TYPICAL
TM TEMPERED WATER
UR URINAL
V VENT
VTR VENT TNRU ROOF
WC WATER CLOSET
WCO WALL CLEAN OUT
WI-1 WATER NEATER
W/ WITH
FC FLOW CONTROL
CONNECTED LOAD
1,419, BTUH TOTAL
RISE UP OUTSIDE BUILDING
AGAINST WALL TO RUN ON
ROOF, PAINT.
GAS COMPANY TO PROVIDE
PRESSURE REGULATOR t
METER.
PAINT VERTICAL RISE
TO MATCH WALL
PROVIDE
PLUG VALVE
UN -1
100,000 BTUH
GAS INPUT
PROVIDE 2 P51 TO 14' WC
PRESSURE REGULATOR ON
ROOF, TYP.
PLUMBING SYMBOLS
---CW
- --- 110'HW
--- - - -- 1401.1141•
-- • • --HWR-
-F
G
-- �—SAN—
V
-- ^- •STM ---
�55D—
-- ----GR
-- - - —XX(
PIPE - UP
PIPE - DOWN
THERMOMETER
PRESSURE GAGE
INLINE PUMP
a:W*4 IA BACK FLOW PREV.
P 4 T RELIEF VALVE
® ACCESS DOOR
aQ COMBINATION BALANCE
/SHUT -OFF
dQ GATE VALVE
0[1 GLOBE VALVE
C> DRAIN VALVE
CONNECT TO
EXISTING
DOMESTIC WATER PIPE
DOMESTIC 140T WATER 1107
DOMESTIC NOT WATER 140'F
DOMESTIC HOT WATER RETURN
SPRINKLER PIPE
GAS PIPE
SANITARY PIPE
SANITARY VENT PIPE
STORM PIPE
SECONDARY STORM PIPE
GREASE SANITARY PIPE
CONDENSATION PIPE
EXISTING PIPE OR EQUIPMENT
'
CHECK VALVE
UNION
GAGE COCK
CHECK VALVE
BUTTERFLY VALVE
BALANCE VALVE
OR GAS VALVE
BALL VALVE
Y- TYPE STRAINER
FLOOR OR AREA
DRAIN
HOSE BIBB
CAPPED LINE
CONCENTRIC
REDUCERS
ECCENTRIC
REDUCER
NOTE: 1. PLUMBING CONTRACTOR SMALL
MAKE ALL FINAL CONNECTIONS
TO HVAC EQUIPMENT.
THERMOSTATIC i'IiIXING VALVE: 3/4'
1207 HPI INLET, 1/2' C11 INLET 3/4'
1107 MI OUTLET MINIi"!1M FLOW OF 0.5
GPM. LEONARD MODE . 210 -58, OR
ENGINEER APPROVED EQUAL.
THERMOMETER.
1114 -1 ELECTRIC RATER HEATER, A.O_
SMITH DEL -10, 1.5 KIN, 120 V, 10.
PROVIDE UNION t SOUTOFF VALVE ON
NW 4 CH LINES. PROVIDE 3/4'
TEMPERATURE/ PRESSURE RELI
VALVE WITH 3/4' DRAIN TO 6' A .
JR -1. PROVIDE DRAIN PAN BY WATER
NEATER 1 FR. PROVIDE SHELF BY
PLATER HEATER 1FFR. MTD. AT 6'-0'
A.F.F. DfTEND 1' DRAIN FROM PAN TO
JR - 1.
1 GALLON AMTROL
EXPANSION TANK.
3/4' ASME
T ET W ERATURE/
PRESSURE RELIEF
VALVE.
1 2'
W1A
3/4'
3/4' CRAM PAN LINE
4 REUEF VALVE
DiSCI4ARGEE TO OVER
FIXTURE
DESIGNATION
UR- 1
is]
N.G.
WATER
CLOSET
(WC-I)
WATER
CLOSET
(WC -2)
LAV -1
5 -1
GG -
JR -1
FP -I
EWC -1
TRAP
Fy PRIMER
SHOCK
ABSORBER
3/4'
3/4'
1 �1
HALL
SCALE: NTS
NOTES
I. SUPPLY AND WHEEL STOPS FOR LAVATORIES, SINKS, AND WATER COOLERS
SHALL BE DEARBORN.
2. SUPPLY AND KEY STOPS FOR WHEELCHAIR LAYS SHALL BE DEARBORN.
3. TRAPS FOR LAVATORIES AND WATER COOL ERS SHALL BE DEARBORN.
4. FLUSH VALVES FOR URINALS SHALL BE DELANY F451.
FIXTURE WC -I SHALL BE WALL MOUNTED ELONGATED STYLE, DIRECT FED SIPHON
JET, REAR OUTLET STYLE; AMERICAN STANDARD #2257.103 AFWALL I.6 GPF COMPLETE
WITH BOWL, I -1/2' TOP SPUD, SLOAN 11111 FLUSIIOMETER VALVE W/ VACUUM BREAKER;
SEAT SHALL BE EQUAL TO CHURCH i19500C. FIXTURE SUPPORT SHALL BE EQUAL TO J.R.
SMITH MODEL 210 AS NEEDED. RIM SNAIL BE SET AT 17' A.F.F. (ADA COMPLIANT) .
MOLDED STONE MOP SERVICE BASIN, 24'X24'X10' WITH FACTORY INSTALLED STAINLESS
STEEL DRAIN BODY WITH STRAINER, CHROME PLATED SERVICE FAUCET WITH WALL BRACE,
PAIL HOOK, HOSE THREAD ON SPOUT, INTEGRAL VACUUM BREAKER, AND INTEGRAL STOPS.
PROVIDE 188 -CC -24 MOP HANGER, HOSE 4 BRACKET AND 11E -77 -AA VINYL BUMPER GUARD.
COATED CAST IRON, TWO -PIECE BODY WITH DOUBLE DRAINAGE FLANGES AND WEEPHOL ES,
BOTTOM CAULK OUTLET AND ADJUSTABLE POLISHED NICKALOY STRAINER. PROVIDE DRAINS
WITH 1/2' TRAP PRIMER CONNECTION. PROVIDE TRAP PRIMERS FOR ALL DRAINS NOT
INDIRECTLY CONNECTED TO THE SANITARY SYSTEM.
SPLIT -LEVEL WALL MOUNTED, WHEELCHAIR ACCESSIBLE ELECTRIC WATER COOLER, ALL
AUTOMATIC WITH TANK, COOLING COIL, INSULATED COOLING SYSTEM, SELF CLOSING TOUCH
PADS WHICH ELECTRONICALLY ACTIVATE EACH BUBBLER VALVE. INSTALL FLEXIBLE SUPPLY
PIPE WITH WHEEL HANDLE STOP AND ADJUSTABLE 'P TRAP.
BRASS FLOOR DRAIN TRAP PRIMER VALVE, AUTOMATICALLY OPENS WHEN LAVATORY FAUCET
15 ACTIVATED.
r
WG-
1/2'
WATER RISER DIAGRAM
1/2'
DESCRIPTION
1/2'
DOMESTIC WATER
METER t REDUCED
PRESSURE BACKFLOW
PREVENTER.
I -1/2'
TP
1/2'
1 -1/2'
1/2'
N 1
PLUMBING FIXTURE SCHEDULE
1 -1/2'
3/4' VERTICAL CW
LINE I5 TO BE
rte. CPOS ED
PIPING CONNECTIONS
COLD
1'
Is
3/4'
1/2'
FIXTURE 104C -2 SHALL BE WALL MOUNTED ELONGATED STYLE, DIRECT FED SIPHON JET,
REAR OUTLET STYLE; AMERICAN STANDARD 112257.103 AFWALL 1.6 GPF COMPLETE
WITH BOWL, I -1/2' TOP SPUD, SLOAN 11111 FLUSHOMETER VALVE W/ VACUUM BREAKER;
SEAT SHALL BE EQUAL TO CHURCH i19500C. FIXTURE SUPPORT SHALL BE EQUAL TO
J.R. SMITH MODEL 210 AS NEEDED. FIXTURE RIM SHALL BE SET AT 15' A.F.F.
WHITE, VITREOUS CHINA WASHOUT URINAL, WALL MOUNTED, INTEGRAL TRAP, 3/4' TOP SPUD
FOR EXPOSED CHROME PLATED FLUSH VALVE, SIDE PRIVACY SHIELDS, WALL HANGER AND
SUPPORTING BOLTS, MOUNT AT ADA HEIGHT.
UNDERMOUNT SINK: OVAL 17' X 14' X 5 -I/2', FRONT OVERFLOW, UNGLAZED RIM FOR
UNDERCOUNTER MOUNT. COLOR 'BONE', PROVIDE WITH UNDERCOUNTER MOUNTING KIT AND
TEMPLATE, ADA COMPLIANT. COORDINATE WITH TENANT.
1/2'
1/2'
(1/2'
PRIMER
CONN .)
1/2'
1/2'
HOT
1/2'
1/2'
TRAP
N/A
N/A
! -1/2'
1 -1/2'
1 -1/2'
3'
3'
1 -1/4'
WASTE
4'
4'
2'
1 -I /2'
IN %`ALL
11b
1 -1/2'
1 —V2'
3'
3'
1 -1/2'
3' VENT TI+RU ROOF
2 '
2'
VENT
2'
F
AMERICAN
STANDARD
2257.103
2'
I -I/2'
1 -1/2'
1 -1/2'
1 -1/2'
2'
1 - 1/2'
1 -1/2'
!--1/2•1
10,4-1
BE..
rYi
FLOOR
ABOVE
CEILbY / I
�
2� I -1/2'1
.62:1 I
.- 1 -1/2'
MANUFACTURER'S CATALOG NUMBER MOUNTING
XTURE OUTLET FAUCET HEIGHT
AMERICAN
STANDARD
2257.103
AMERICAN
STANDARD
6501.010
AMERICAN
STANDARD
04'15.221
ELKAY
LRAD -2521
-55 -3
INSINKER-
ATOR
555/55
FIAT
M5B -2424
J. R. SMITH
2005A -P050
-
OASIS
P8AMSL
PRECISION
PLUMBING
PRODUCTS
'PRIME -
RITE'
BE4.O":
FLOOR
IN %MALL
STOP
DEARBORN
2720SCW
DEARBORN
27205CW
DEARBORN
2712CW
- •
•
LAV -1
BELOW
FLOOR
SANITARY WASTE STACK
SCAL = =%TS
SLOAN
186 -1
CHICAGO CHICAGO
FAUCET FAUCET
327 -ACP 802.CP
GRID W/
DRAIN AERATOR
LK -35 ELKAY
BASKET LK -2433
STRAINER
INTEGRAL FIAT
830 -AA
3'
1/2'
WIA
I -1/2'
114 CHASE, TYP.
BELOW
• FLOOR
i _ _
- . - .
� i :
� ; , .
Irr. _
' _� j C 1
17' TO
RIM
15' TO
RIM
17' TO
URINAL LIF
44' MAX
TO FLUSH
VALVE.
34' TO
RIM
18 GAUGE, TYPE 302 (I0-8) NICKEL BEARING STAINLESS STEEL, SELF- RIMMING, SINGLE
COMPARTMENT SINK. FURNISH WITH TOP MOUNT TWO HANDLE FAUCET, CHROMED METAL
WING HANDLES, SWING SPOUT, AERATOR, AND REMOVABLE BASKET STRAINER. INSTALL
FLEXIBLE SUPPLY PIPES WITH WHEEL DANDLE STOPS AND ADJUSTABLE 'P' TRAP.
FOOD WASTE DISPOSER WITH 51100144, BAKED ENAMEL FINISH, SHOCK MOUNTED FOR QUIET
OPERATION, STAINLESS STEEL CUTTING TEETH, RUST AND CORROSION RESISTANT GRINDING
CHAMBER, LIFETIME LUBRICATED 3/4 H.P. MOTOR AND BEARINGS, BUILT -IN MANUAL RESET
OVERLOAD PROTECTOR. INSTALLATION BY P.G., WIRING BY E.G. 120 VOLT.
COUNTER
ON SINK
OUTLET
FLOOR
MOUNTED
FLUSH W/
FLOOR
PER
MFR.
SPEC.
EXPOSED
BELOW
LAVATORY
1/2' LINE -I: QC i
TP, TYP.
PE i' 11 C F‘ - c
1/)
0
Z
a �
cki 4:4
W v�
nasal0s:>9assw.B.o •:Va
tA144.Mat :ea Mar 2EiEOILAPSf R
owxcamt Nom s wrosaiso+vtza)
t1. tP,B..0 iO•1311,.d sO.MIt RCN
MK tasnams saarirvtCIMEe•
NUS ili s a•cle saitswocsasa w
SAI t OROS
DRAWING MASER:
P5.1
1
15010 GENERAL PROVISIONS
A. PROVIDE ALL MATERIALS AND EQUIPMENT AND
PERFORM ALL LABOR REQUIRED TO INSTALL. A
PLUMBING SYSTEM, COMPLETE AS INDICATED 014 THE
DRAWINGS, AS REQUIRED BY CODE AND AS SPECIFIED
HEREIN.
B. WITHOUT RESTRICTING THE GENERALITY OF THE FIRST
STATEMENT, THE WORK TO BE PERFORMED UNDER
THIS DIVISION SHALL INCLUDE, BUT 15 NOT LIMITED
TO, THE FOLLOWING:
I) PLUMBING WORK AS DESCRIBED IN SECTIONS
16010 THROUGH 15376.
2) FIRE PROTECTION WORK AS DESCRIBED IN
SECTIONS 15010 AND 15410 THROUGH 15430.
C. THE ELECTRICAL. CONTRACTOR, UNLESS OTHERWISE
NOTED, I5 TO PROVIDE POWER WIRING FOR EACH ITEM
OF ELECTRICAL EQUIPMENT AND MAKE FINAL
CONNECTION TO MOTORS.
D. ALL FINISH PAINTING I5 TO BE PERFORMED BY THE
GENERAL CONTRACTOR, EXCEPT AS NOTED
ELSEWHERE. THIS CONTRACTOR SHALL RESTORE TO
ORIGINAL CONDITION ANY PAINTING DEFACED BY 14111
AFTER ORIGINAL PAINTING.
E. ALL WORK SHALL CONFORM TO CODES, RULES, AND
REGULATIONS:
I) STATE PLUMBING CODE.
2) LOCAL BUILDING CODE.
3) NATIONAL FIRE PROTECTION ASSOCIATION.
4) CERTAIN CODES AND STANDARDS AS SET UP BY
VARIOUS TECHNICAL SOCIETIES SUCH AS ASME,
A5HRAE, ASTM, SMACNA, ARI, AABC, OR IEEE.
5) FEDERAL OCCUPATIONAL SAFETY AND HEALTH
STANDARDS.
6) LOCAL INSPECTOR'S REQUIREMENTS.
7) STATE INDUSTRIAL COMMISSION REQUIREMENTS.
8) BUILDING INSURING AGENCY
REQUIREMENTS.
F. ALL PERMITS REQUIRED BY LAWS, ORDINANCES AND
BUILDING CODES HAVING JURISDICTION SHALL BE
OBTAINED AT THE PROPER TIME BY AND AT THE
EXPENSE OF TI-115 CONTRACTOR.
G. THIS CONTRACTOR SHALL OBTAIN ALL INSPECTIONS
REQUIRED BY ALL LAWS, ORDINANCES AND PUBLIC
AUTHORITY HAVING JURISDICTION AND SHALL OBTAIN
CERTIFICATES OF SUCH INSPECTIONS AND SUBMIT
SAME TO THE ARCHITECT AND SHALL PAY ALL FEES,
CHARGES, ASSESSMENTS AND OTHER EXPENSES IN
CONNECTION THEREWITH.
N. PIPING AND EQUIPMENT LAYOUT IS SCHEMATIC. EXACT
LOCATIONS ARE DETERMINED BY STRUCTURAL AND
OTHER CONDITIONS. DESIGN OF SYSTEM MAY NOT BE
CHANGED. ONLY EXACT LOCATION OF PIPING MAY BE
REVISED TO SUIT CONSTRUCTION CONDITIONS AND AID
IN COORDINATION WITH WORK OF OTHER
CONTRACTORS.
I. THE MATERIALS AND EQUIPMENT INSTALLED IN TIME
WORK SHALL MEET TIIE REQUIREMENTS OF THE
CONTRACT DOCUMENTS AND NO MATERIALS OR
EQUIPMENT SHALL BE ORDERED UNTIL REVIEWED BY
THE ENGINEER AND/ OR ARCHITECT.
J. THE CONTRACTOR SHALL SUBMIT FOR THE
ARCHITECT'S REVIEW SIX (6) COMPLETE COPIES OF
THE CATALOG DATA AND /OR SHOP DRAWINGS (SEPIAS
AT CONTRACTOR'S OPTION) FOR THE FOLLOWING ITEMS
OF EQUIPMENT AND COMPONENTS TO BE USED IN THE
WORK, INCLUDING SPECIFIC PERFORMANCE DATA,
MATERIAL DESCRIPTION, RATING, CAPACITY, WORKING
PRESSURE, MATERIAL GAUGE OF THICKNESS, BRAND
NAME, CATALOG NUMBER AND GENERAL TYPE. THE
SUBMISSION SHALL BE COMPILED BY THE CONTRACTOR
AND REVIEWED BY THE ENGINEER BEFORE ANY OF THE
EQUIPMENT I5 ORDERED.
1. EXPANSION TANK
2. THERMOSTATIC MIXING VALVE
3. DRAINS AND CLEANOUTS
4. VALVES
5. ALL PLUMBING FIXTURES, FAUCETS AND FITTINGS
6. THERMOMETERS
7. GARBAGE GRINDER
6. SHOCK ABSORBERS
9. ELECTRIC WATER HEATER
10_ PIPE INSULATION
K. CATALOG DATA FOR EQUIPMENT REVIEWED BY THE
ARCHITECT SHALL NOT SUPERSEDE THE ENGINEER'S
CONTRACT DOCUMENTS. THE REVIEW OF THE ENGINEER
SMALL NOT RELIEVE THE CONTRACTOR FROM
RESPONSIBILITY FOR DEVIATIONS FROM DRAWINGS OR
SPECIFICATIONS, PROVIDING PROPER CLEARANCE
FABRICATION PROCESS AND COORDINATION WITH OTHER
TRADES.
L. WA EN SL.'9MITTED FOR THE ARCHITECT'S REVIEW, 514OP
DRAWINGS SHALL BEAR THE CONTRACTOR'S
CERTIFICATION THAT THEY HAVE REVIEWED, CHECKED
AND APPROVED THE SHOP DRAWINGS, THAT THEY ARE
IN HARMONY WITH THE REQUIREMENTS OF THE PROJECT
AI0 KITH THE PROVISIONS OF THE CONTRACT
DOCW`1ENITS AND THAT THEY PAVE VERIFIED ALL FIELD
MEASUREi IENTS AND CONSTRUCTION CRITERIA,
MATERIALS, CATALOG NIRSBERS AND SIMILAR DATA.
CONTRACTOR SHALL ALSO CERTIFY THAT THE WORK
REPRESENTED BY THE SHOP DRAWINGS 15
RECOM ID4DED BY i 'E CONTRACTOR AND THE
CONTRACTOR'S GUARA.NITEE WILL FULLY APPLY_
M ALL CONTRACTORS SUBMITTING PROPOSALS FOR THIS
WORK SMALL FIRST EXAM ME THE SITE AND ALL
CONDITIONS THEREIN. ALL PROPOSALS SHALL TAKE
INTO CONSIDERATION ALL SUCH CONDITIONS AS MAY
AFFECT THE 4OR< UNDER TINS CONTRACT. THE
SLIB`:ITTINiG OF A BD AUTOMATICALLY IMPLIES THAT
T 5 EXA 1,NATIOI fF. SITE IUAS BEEN DONE
N. CONTRACTOR SHALL VERIFY LOCATION OF UTILITIES
AND NOTE CONDITIONS 14-1414 &r OULD AFFECT THE
WORK_ ALL DiSCREPANCJES WALL TI3E.►N BE REPORTED
PRIOR TO THE BD AWARD.
G
etRov.rem :`STI$ICTtOK TO TEN: T'S OPERATING
PERSO NE:. AS NE :ESSARY, SHOWNG LOCATIONS AND
PROPER OPERATION Of MAJOR ITEMS OF EQUIPMENT
AND SYSTE:I COMPONENTS AND REFERRING TO THE
OPERATING tNSTR..CT:01 . S A.WAAL DESCRIBED BELOW
AS
P A n :I -TEN "A.NuA _ OF OPERATING
`S T RuCT. - S IvGLLicDtNCs CCP■ES OF SHOP DRAW;NGsS
AN L: A US: LNG OF EOU -.'tiT S- PPL$ERS- ASSD'aLE
V 6 - ;/2' X I:' HA.W BACKED INDE. XED B4‘.DER.
E'JA T ERA AL rr -ALL BE AS F' ' OI S
L
•
15100 PLUMBING BASIC MATERIALS AND METHODS
c.
D.
I) TITLE PAGE= TITLE OF JOB, TENANT, ADDRESS,
DATE OF SUBMISSION, CONTRACTOR AND ENGINEER_
2) INDEX
3) LIST OF MAJOR EQUIPMENT USED IN PROJECT
ACCOMPANIED BY CONTRACTOR PURCHASE ORDER
NUMBERS AND SUPPLIERS NAMES AND ADDRESSES.
4) ONE COPY OF EACH SHOP DRAWING GROUPED BY
TYPES OF EQUIPMENT, I.E., PLUMBING FIXTURES,
VALVES, ETC.
5) SECTION FOR EACH SYSTEM INCLUDING:
A) BRIEF DESCRIPTION OF SYSTEM OPERATION WITH
LOCATION OF MAJOR COMPONENTS.
Q. SUBMIT A COMPLETED COPY TITLED 'PLUMBING
OPERATING INSTRUCTION MANUAL' ON THE BINDING EDGE
OF BINDER TO ARCHITECT FOR APPROVAL. AFTER
ARCHITECT'S REVIEW AND ANY CORRECTIONS REQUIRED
ARE COMPLETED, SUBMIT A COPY OF THE MANUAL TO
THE TENANT.
A. PROVIDE AND ERECT THE FOLLOWING PIPING AS SHOWN
ON THE DRAWINGS AND /OR AS REQUIRED.
I) SANITARY BUILDING DRAIN AND VENT PIPING SHALL
BE SERVICE WEIGHT CAST IRON SOIL PIPE.
2) SCHEDULE 40 PVC PIPING MAY BE USED FOR
SANITARY WASTE AND VENT PIPING IF CEILING
SPACE I5 NOT USED AS A RETURN AIR PLENUM
SPACE AT THE CONTRACTOR'S OPTION.
3) DOMESTIC 140T AND COLD WATER USE TYPE 'L'
HARD COPPER PIPE.
B. THIS CONTRACTOR 15 TO BECOME INFORMED OF THE
EXACT DIMENSIONS OF FINISHED WORK WHERE PIPES ARE
TO BE PLACED AND WILL ARRANGE THE WORK
ACCORDINGLY, ASSUMING ALL RESPONSIBILITY FOR
PROPER LOCATION. IN THE ERECTION OF THE MAINS,
SPECIAL CARE SHALL BE USED PROVIDING SUPPORT AND
PROPER ALLOWANCES SHALL BE MADE FOR EXPANSION.
C. ALL PIPE LINES MUST BE PROVIDED WITH A SUFFICIENT
NUMBER OF FITTINGS OR UNIONS TO MAKE POSSIBLE
DISASSEMBLY WITHOUT BREAKAGE OF FITTINGS.
D. ALL EXPOSED PIPING SHALL BE NEAT AND CAREFULLY
AUGNED WITH THE STRUCTURAL ELEMENTS OF THE
BUILDING. NO OFFSETS OR OBLIQUE BENDS WILL BE
PERMITTED. DRAWINGS ARE DIAGRAMMATIC AND SHOULD
NOT BE USED FOR LAYOUT WORK.
E. ALL LOW POINTS IN WATER PIPING TO HAVE DRAIN VALVES
WITH STANDARD HOSE ATTACHMENTS. HOT AND COLD
WATER PIPING IS TO PITCH TOWARD THE NEAREST DRAIN
VALVE.
F. ALL PIPES TO BE INSTALLED SHALL BE LOCATED AT
SUFFICIENT DISTANCE FROM WALLS, OTHER PIPES,
CONDUIT, DUCTWORK AND OTHER OBSTACLES TO AVOID
INTERFERENCE AND TO PERMIT THE APPLICATION OF FULL
THICKNESS OF INSULATION SPECIFIED.
G. MECHANICAL JOINT TYPE PIPING 514ALL BE INSTALLED PER
MANUFACTURER'S RECOIINENDATIONS.
H. FURNISH AND INSTALL IN THE PIPING LEAVING THE WATER
HEATERS, THERMOMETERS AND WELLS FOR MEASURING THE
WATER TEMPERATURES- THERMOMETERS ARE TO BE GLASS
WITH 9' SCALES AND GRADUATED 50 THAT EXPECTED
TEMPERATURE IS MIDWAY OF SCALE, STAINLESS STEEL
FRONT, SEPARABLE SOCKET AND GLASS WINDOWS.
THERMOMETERS BY TRERICE, ASHCROFT, MARSHALLTOWN,
AND WEISS ARE ACCEPTABLE.
15130 EXCAVATION AND BACKFILL
A. 11415 CONTRACTOR SHALL EXCAVATE AND BACKFILL ALL
TRENCHES AND OTHER EXCAVATIONS REQUIRED FOR LAYING
DRAINS, SEWERS, APPURTENANCES AND OTHER EXCAVATIONS
REQUIRED FOR 1415 WORK.
5. EARTH FILL: SOIL AS APPROVED BY THE OWNER'S
REPRESENTATIVE, FREE OF ORGANIC SOIL, SOD, ROOTS, WOOD,
METAL, RUBBISH, DEBRIS, LUMPS OR EXCESSIVE AMOUNTS OF
CLAY AND ROCKS GREATER THAN 2' IN DIAMETER; CAPABLE
OF BEING COMPACTED INTO DENSE AND STABLE CONDITION AS
SPECIFIED.
C. ALL UNDERGROUND PIPING 514ALL BE INSTALLED ON A MINIMUM
OF A 3' BED OF COMPACTED SAND. ALL UNDERGROUND PIPING
SHALL BE BACKFILLED BY HAND TO A LEVEL OF 6' ABOVE THE
PIPE WITH CLEAN SAND. ALL BACKFILL SHALL BE MADE IN
LIFTS NOT TO EXCEED 12'. EACH UFT SHALL BE MECHANICALLY
COMPACTED TO A MINIMUM OF 4 122 MODIFIED PROCTOR.
D. PROTECT ALL UTILITIES 5IIOWN ON DRAWINGS OR ENCOUNTERED
IN THE CONSTRUCTION WORK. ANY DAMAGE TO UTILITIES SHALL
BE REPAIRED BY THIS CONTRACTOR TO OW'NER'S SATISFACTION,
WITHOUT COST TO THE OWNER.
E. THIS CONTRACTOR SHALL REMOVE ANY UNUSABLE OR
SURPLUS EXCAVATED MATERIAL FROM SITE.
15200 PLUMBING SYSTEMS
A. SANITARY BUILDING DRAIN, 50JL, WASTE AND VENT LINES
SHALL BE SERVICE WEIGHT CAST IRON IEUBLESS PIPE MUTH
STAINLESS STEEL AT COUPLINGS. SCHEDULE 40 PVC MAY
BE USED FOR SANITARY WASTE AND VENT PIPING IF CEILING
SPACE I5 NOT USED AS A RETURN AIR PLENUM_
B. VENT STACKS SMALL EXTEND THROUGH THE BUILDING,
TERMINATING i2' ABOVE THE ROOF. STANDARD FLASHING
SHALL BE EXTENDED 12' IN ALL DIRECTIONS FROM THE VENT
TERMINAL AND TURNED DOWN INTO VENT- FLASHING UNITS
AS MADE BY STONEMAN CAULK TYPE NO. 5:110 -4 MAY BE
USED iN LIEU OF FIELD FABRICATED FLASIENGS.
HORIZONTAL R„`S SMALL BE GIVEN AS STEEP A PITCH
TOWARD THE OUTLET AS CONDITIONS WILL PERMIT BUT
NOT LESS THAN I18' PER FOOT
FULL M BRANCH FITTINGS AND EXTENSION WITH BRASS
NIPPLES AND FINISHED SCREini PLUGS FOR CLEANOUTS
SHALL BE PLACED IN ACCESSIBLE POSITIONS AT ENDS OF
HORIZONTAL LIMES OF PIPE AND AT FOOT OF ALL.
VERTICAL UNE5 OF PIPE OR ELSEAHERE, AS MAY BE
REQUIRED BY THE CODE.
E. 1Q -TREE CLEANOUTS OCCUR .NI FIN S:4ED AREAS, TWEY
504ALL BE RECESSED AND COVERS TO BE FLUSH W.Tid THE
FLOOR CR :4:._L.
F. 1101 AND COLD ;-4ATER PIPING, ABOVE GROUND, SFIALL BE
TYPE 'L.' HARD COPPER TUBE W-T.1 SOLDER FITTINGS_
EXPOSED PIPING AT FIXTURES SHALL BE 04RaIE PLATED
BRASS.
G. ALL COPPER TUBING SHALL HAVE SWEAT JOINTS AND BE
CLEAN OF SCALE AND FOREIGN MATTER BEFORE
INSTALLATION. ALL ENDS OF TUBING TO BE SWEATED
SHALL BE REAMED, CLEANED AND BURNISHED TO REMOVE
DIRT AND OXIDE. HARD 95 -5 SOLDER SHALL BE USED AND
APPLIED TO THE JOINTS ACCORDING TO STANDARD
PRACTICE AND /OR MANUFACTURER'S RECOMMENDATIONS.
SUITABLE ADAPTERS SHALL BE USED AT CONNECTION TO
EQUIPMENT.
H. EACH HOT AND COLD WATER BRANCH SHALL BE
PROVIDED WITH A GATE VALVE SHUT -OFF AND EACH
FIXTURE SHALL BE PROVIDED WITH A STOP VALVE.
15220 GAS PIPING
A. STANDARD WEIGHT BLACK STEEL PIPE. FITTINGS FOR LINES
I -1/2' AND LARGER SHALL BE WELDED STEEL. FITTINGS FOR
LINES l -1/4' AND SMALLER, EXCEPT WHEN LOCATED IN AIR
PLENUMS, SHALL BE SCREWED STANDARD WEIGI•IT BLACK
MALLEABLE. ALL GAS PIPING LOCATED IN AIR PLENUMS SHALL
BE STANDARD WEIGHT BLACK STEEL W/ STANDARD WEIGHT
WELDED TYPE FITTINGS. 140 VALVES ARE TO BE LOCATED IN
AIR PLENUMS.
B.
C.
D.
E. PROVIDE UNION AT ALL EQUIPMENT CONNECTIONS.
15250 EQUIPMENT IDENTIFICATION
A. STENCILS, LABELS, TAGS, AND COLOR CODES
SHALL CONFORM TO ANSI A13.
B. PRODUCTS SHALL BE SETON. EQUAL PRODUCTS BY
BRADY MAY BE FURNISHED AT CONTRACTOR'S OPTION.
C. STENCILS SHALL BE REUSABLE AND HAVE I' HIGH
CHARACTERS. CHARACTERS SHALL BE PAINTED WHITE
OVER A BLACK BACKGROUND. INCLUDE ON PIPING A WHITE
(OR BLACK) STENCILED ARROW IN FLOW DIRECTION NEXT
TO STENCIL. STENCIL ONLY AFTER FINAL PAINTING 15
COMPLETE. CHARACTERS SHALL BE LEGIBLE FROM FLOOR.
APPLY CLEAR ACRYLIC, LACQUER, OR VARNISH OVER THE
FINISHED STENCIL.
D. PREPRINTED FLEXIBLE VINYL LABEL WITH PERMANENT
PRESSURE SENSITIVE ADHESIVE BACK MAY BE USED ON
PIPE INSTEAD OF STENCIL. LABEL SHALL BE OF SUFFICIENT
LENGTH TO ENCIRCLE THE PIPE (AND INSULATION WHEN
APPLICABLE) AND OVERLAP ON ITSELF. EACH LABEL
SHALL HAVE AT LEAST ONE FLOW DIRECTION ARROW AND
SHALL BE PERMANENTLY LABELED WITH PIPE CONTENT.
E. PIPING, VALVES, DRAINS, CONTROL PANELS AND SIMILAR
EQUIPMENT SHALL BE IDENTIFIED AS TO FUNCTION AND
SYSTEM NUMBER AS DIRECTED BY THE TENANT'S
REPRESENTATIVE AND AS LISTED BELOW:
G. PIPE STENCIL SCHEDULE:
COLOR
SERVICE CODE
15275 STERILIZATION
A.
B.
GAS COCK'S 1 -1/2' AND SMALLER SHALL BE ALL BRONZE,
SCREWED, FLAT HEAD, BRASS PLUG AND WASHER 200 LB.
NOG.
PROVIDE LINE SIZE 6' LONG DIRT LEG AND GAS COCK AT
ALL EQUIPMENT CONNECTIONS.
ALL EQUIPMENT SHALL SHALL BE CONNECTED WITH RIGID
PIPING AS SPECIFIED ABOVE, FLEXIBLE CONNECTORS ARE NOT
ACCEPTABLE.
ITEM
IDENTIFICATION
PIPING
VALVES
PIPING SPECIALTY
WATER HEATER AND OTHER
EQUIPMENT
DOMESTIC COLD LIGHT
WATER SUPPLY BLUE
DOMESTIC 1101 DARK
WATER SUPPLY BLUE
SANITARY SEWER
TYPE
STENCIL OR PIPE
LABEL
TAG
TAG
STENCIL
F. IDENTIFY PIPE LINES WITH STENCIL OR PIPE LABEL WITH
COLOR CODED BANDS AT TIIE FOLLOWING LOCATIONS:
1) AT EQUIPMENT CONNECTION AT EACH VALVE.
2) AT BOTH SIDES OF WALLS THROUGH WHICH PIPE PASSES.
3) AT EVERY 20 FT. INTERVAL ON CONTINUOUS PIPE LINES.
4) AT EACH BRANCH CONNECTION.
5) SHOW FLOW DIRECTION ARROWS AT EACH IDENTIFICATION
POINT.
STENCIL
DESIGNATION
STERILIZE NEW DOMESTIC WATERLINES AFTER
INSTALLATION
TAG
DESIGNATION
D.C.W.S. D.C.W.S.
D.H.W.S. D.H.W.S.
SAN.
H. TAG ALL VALVES AND PIPE SPECIALTY WITH A NUMBER.
FURNISH A SCHEDULE OR SCHEDULES Of ALL VALVES OR
DEVICES TAGGED WITH NUMBER, LOCATION AND PURPOSE
OF EACH VALVE AND INCLUDE IN OPERATING AND
MAINTENANCE MANUAL.
FURNISH A CERTIFICATE OF STERILIZATION AND APPROVAL
FOR I4IR'IAH CONSLR PTION TO BE SIGNED BY A
PROFESSIONAL ENGINEER REGISTERED IN THIS STATE,
REGULARLY a DLoYED BY THE TESTING LABORATORY.
CERTIFICATE MUST BE GIVEN TO THE ARCHITECT AND
TENANT BEFORE FINAL PAY; ENT HILL BE MADE.
C. STERILIZATION SIALL BE BY MEANS OF CiTSORINE INJECTED
INTO THE WATER SYSTEM NEAR THE SOURCE AND OUTLETS
THE SYSTEM SHALL BE TESTED TO PROVE
PRESENCE OF i :NH'RR1 REQUIRE ia1TS_ LEAVE CHLORINE IN
FOR 24 HOURS AND FLUSH OUT SYSTEM UPON COMPLETION
OF WORK. STEIRILIZATION PROCEDURE SHALL BE WITNESSED
BY THE TENANT'S REPRESENTATIVE.
D. STER+LIZAT'AN SHALL BE PERFOWIED BNDER THE !MEDIATE
SLiPERViSiON OF A WATER TES T iHG LABORATORY REGULARLY
ENGAGED I.N THE SERVCE AND SHALL BE OO.+iE ACCARD:NG
TO THEIR INSTRUCTIONS.
15300 ELECTRIC WATER CATER
A_ FURS :511 AND INSTALL ELECTRIC ATER ~EATER, SIZE,
LOCATION AND CAPACITY AS INDICATED ON THE DRAWINGS.
3. WATER r - ..t r ER SHALL BE a0 5.` : -i. EEGth% . HEATERS BY
RUN, A►rrOZCAN, STATE, OR LOG- i VAR MAY BE
Fi;R.. SSED AT THE CONTRACTOR'S GP i GN.
C. TANK TYPE ELECTRIC WATER HEATER ,.T4 GIASS-L;INED TA.'4(
RATED AT 150 P5+ iNURI : N;G PRESSER:, r tLG*i,=_S..X i ANODE.
PROTECTION, BRONZE DRA'N VALVE, 14.4k I ErPERATURE
CUT -OFF 5 TO1 AND h`2".ERSONI T.4E.Q^'IOSTAT. TANK TO
BANG A MtNRiPIT III R -VAWE OF *O.
FIRE PROTECTION AND PLUMBING SPECIFICATIONS
D. FURNISH AND INSTALL A WATTS NO. 40L, 3/4'
TEMPERATURE AND PRESSURE RELIEF VALVE AND EXTEND
DISCHARGE PIPE, FULL. SIZE, TO WITHIN 6' ABOVE THE
JANITOR'S RECEPTOR OR FLOOR DRAIN.
C.
D.
PROVIDE AATROL EXPANSION TANK AS SIZED ON THE
DRAWINGS. EQUAL PRODUCTS BY BELL AND GOSSETT OR
ADAMSON MAY BE PROVIDED AT THE CONTRACTOR'S OPTION.
15325 PLUMBING FIXTURES AND EQUIPMENT
A. WATER CLOSETS, URINALS AND LAVATORIES SHALL BE
VITREOUS CHINA BY AMERICAN STANDARD. EQUAL PRODUCTS
BY KOHLER OR CRANE MAY BE PROVIDED AT THE
CONTRACTOR'S OPTION. VITREOUS CHINA FIXTURES SHALL ALL
BE BY THE SAME MANUFACTURER.
B. ALL WALL HUNG WATER CLOSETS, LAVATORIES, URINALS AND
TRIM, FLUSH VALVES, ETC., SHALL BE MOUNTED AT THE
MANUFACTURER'S RECOMMENDED ROUGHING IN
MEASUREMENTS, UNLESS NOTED OTHERWISE.
C. VALVES TO BE AS FOLLOWS:
125 LB. S.W.P. GATE, GLOBE AND CHECK VALVES:
1) GATE (2 -1/2' AND SMALLER) - ALL BRONZE, SCREWED,
TAPERED, SOLID WEDGE DISC, SCREWED BONNET,
RISING STEM.
2) BALL (2 -1/2' AND SMALLER) - ALL BRONZE, TEFLON
STEM SEALS AND SEAT, 1/4 TURN SHUT -OFF, VINYL
COVERED HANDLES.
3) GLOBE (2 -I/2' AND SMALLER) - ALL BRONZE, SCREWED,
TAPERED, SOLID WEDGE DISC, SCREWED BONNET, RISING
STEM.
4) CHECK (2 -1/2' AND SMALLER) - ALL BRONZE, SCREWED,
HORIZONTAL SWING CHECK WITH BRONZE DISC.
D. VALVES SHALL BE MILWAUKEE. EQUAL PRODUCTS BY CRANE,
HAMMOND, POWELL, WALWORTH, NIBCO OR STOCKHAM MAY BE
FURNISHED AT THE CONTRACTOR'S OPTION.
. UNIONS TO BE AS FOLLOWS:
I) UNIONS FOR COPPER PIPE TO BE 150LB., ALL BRONZE,
SOLDER END TYPE BY CHASE. EQUAL PRODUCTS BY
CRANE, MUELLER OR NORTHERN INDIANA BRASS COMPANY
MAY BE FURNISHED AT THE CONTRACTOR'S OPTION.
2) DIELECTRIC UNIONS BETWEEN FERROUS AND COPPER
SHALL BE INSULATED TO PREVENT METAL -TO -METAL
CONTACT AND SHALL BE MANUFACTURED BY CAPITAL
MANUFACTURING COMPANY OF COLUMBUS, 01410. EQUAL
PRODUCTS BY PATROL OR PECO SALES COMPANY
. CLEANOUTS TO BE AS FOLLOWS:
I) FLOOR TYPE TO BE ADJUSTABLE CAST IRON WITH NICKEL
BRONZE TOP. ZURN I:ZN- 1400 -T. TOP TO BE FLUSH WITH
FLOOR.
2) WALL TYPE TO BE CAST IRON TEE WITH ROUND POLISHED
STAINLESS STEEL ACCESS COVER AND THREADED PLUG.
ZURN *Z -1446.
G. FLOOR DRAINS TO BE AS FOLLOWS:
1) CAST IRON BODY SHALLOW SUMP DRAIN WITH DOUBLE
DRAINAGE FLANGE AND WEEPHOLES, FLASHING CLAMP,
BOTTOM OUTLET WITH NEOPRENE GASKET INSIDE
CONNECTOR, 6' DIAMETER ADJUSTABLE GRATE. FRAME
AND GRATE TO HAVE POLISHED NICKEL- BRONZE FINISH.
SEE DRAWINGS FOR MODEL AND MANUFACTURER. EQUAL
PRODUCT MAY BE SUPPLIED AT THE CONTRACTOR'S
OPTION.
15330 GARBAGE GRINDER
A. FURNISH AND INSTALL GARBAGE GRINDERS WHERE SHOWN
ON THE DRAWINGS_
B. FOOD WASTE DISPOSER WITH SMOOTH BAKED ENAMEL FINISH,
SHOCK MOUNTING FOR QUIET OPERATION, STAINLESS STEEL
CUTTING TEETH, RUST AND CORROSION RESISTANT GRINDING
CHAMBER, LIFE -TIME LUBRICATED MOTOR AND BEARINGS,
BUILT -IN MANUAL RESET OVERLOAD PROTECTION.
MOTOR - 3/4 HP, 120 VOLT, 60 HERTZ, SINGLE PHASE.
DISPOSERS BY INSINKERATOR, BUS BOY OR HOBART OF THE
SAME TYPE AND MEETING SPECIFICATIONS MAY BE
FURNISHED AT THE CONTRACTOR'S OPTION.
INSTALL IN ACCORDANCE WITH THE MANUFACTURER'S
RECOMMENDATIONS, AND COMPLYING WITH THE
REQUIREMENTS OF THE INSPECTION/APPROVAL AUTHORITIES.
15350 INSULATION
A. PIPE INSULATION AND APPURTENANCES AND COVERINGS ON
PIPES USED IN CHASES, SHAFTS OR OTHER CONCEALED
SPACES IN TYPES 1 AND 2 CONSTRUCTION SHALL HAVE A
FLAME SPREAD RATING NOT EXCEEDING TWENTY -FIVE (25)
AND IN TYPE 3 AND 4 CONSTRUCTION NOT EXCEEDING
SEVENTY -FIVE (75) AND A SMOKE DEVELOPED RATING NOT
EXCEEDING FIFTY (50).
B. INSULATION SHALL BE SCHULLER MICRO -LOK 650 FIBERGLASS
WITH FACTORY APPLIED ALL SERVICE JACKET WITH
SELF - SEAUNG TAPE.. INSULATION SHALL LIMIT HEAT LOSS TO
25 BTU/HR. /SQ.FT. OF PIPE SURFACE WITH 56 DEGREES
AMBIENT, AND SHALL BE 1/2' TRICK ON COLD WATER PIPING
AND 1' THICK ON HOT PLATER PIPING_ INSULATE ALL DOMESTIC
WATER PIPING.
GLUE IN PLACE WITH SCHULLER U -GLUE.
D. THE FITTINGS SHALL BE INSULATED WITH SCI&ILLER ZESTON
INSULATION AND HAVE FACTORY PREMOLDED PVC COVERS.
BUTT THE JOINTS TOGETHER AND WRAP WITH 3' WIDE STRIP
TAPE, SEAL IN PLACE HITli SO ULLER U-GLUE.
INSULATION WALL NOT EE APPLIED UNTIL THE GENERAL
CONSTRUCTION HAS PROGRESSED SUFFICIENTLY TO INSURE
AGAINST PHYSICAL OR MOISTURE DAMAGE TO THE INSULATION.
ALL INSULATION DAMAGED THROUGH FAILURE TO OBSERVE
THIS DIRECTIVE SHALL BE REPLACED AT PLUMING
CONTRACTOR'S OCPENiSE-
F. INSTALL ALL iNSULATtON ACCORDING TO MANUFACTURER'S
RECC IDDATION.S.
G. INSULATION SHALL NOT BE APPLIED OIER FLANGES, JOINTS
AND SEAM Ili PIP \iG.
A'■►SULATIOs WALL BE SCHULLER. EQUAL PRODUCT BY
A.REISTRONG, CERTAINTEED, 0.0:0:S-CORNING, OR Kr1AUs` MdAY
BE FURNaSI AT THE. CONTRACTOR'S OPTION.
15375 PLUMBING SYSTEM TESTING
A. SYSTEM TESTING SHALL PROVIDE FOR THE FOLLOWING:
G.
H.
I) TEST NEW INTERIOR DOMESTIC WATER SYSTEM.
2) TEST ALL SOIL, WASTE, AND VENT PIPING.
3) FURNISH ALL PUMPS FOR AIR AND WATER PRESSURE
TESTS ALONG WITH GAUGES AND ANY OTHER REQUIRED
TEST EQUIPMENT.
4) UNDERGROUND LINES TO BE TESTED BEFORE BEING
CONCEALED. CONTRACTOR SHALL REPAIR ANY LEAKS AND
ALL DAMAGE RESULTING THEREFROM.
5) CHANGES IN AMBIENT TEMPERATURE WILL BE TAKEN INTO
ACCOUNT WHEN TESTING UNDERGROUND PIPING, HOWEVER,
THE VARIOUS SYSTEMS SHALL BE THOROUGHLY
INSPECTED FOR LEAKS BEFORE HYDROSTATIC PRESSURE
TESTS ARE CONCLUDED.
6) INTERIOR WATER PIPING: HYDROSTATIC TEST AT 125 PSI
ANNA PROCEDURES.
7) SOIL, WASTE, AND VENT PIPING SHALL BE WATER AND
SMOKE OR AIR TIGHT (STATE PLUMBING CODE).
B. MEASURE LEAKAGE BY METERING WATER REQUIRED TO
MAINTAIN LINE PRESSURE. REMOVE AIR BEFORE TESTING.
C. REPAIR ANY LEAKING JOINTS AND DEMONSTRATE
ACCEPTABLE LEAKAGE TO SATISFACTION OF TENANT'S
REPRESENTATIVE AND APPROVING AUTHORITY. FLUSH ALL
PIPING BEFORE PLACING INTO OPERATION.
15410 FIRE PROTECTION GENERAL PROVISIONS
A. SPRINKLER CONTRACTOR SHALL REUSE AS MUCH AS POSSIBLE
FROM THE EXISTING SPRINKLER SYSTEM. DESIGN NEW
SPRINKLER SYSTEM TO MEET ALL LOCAL AND STATE
REQUIREMENTS.
B. FURNISH ALL MATERIALS, LABOR, TOOLS, ADMINISTRATION,
TRANSPORTATION, INCIDENTALS AND APPURTENANCES WHICH
ARE REQUIRED TO COMPLETE IN EVERY DETAIL AND LEAVE IN
WORKING ORDER ALL ITEMS OF WORK CALLED FOR HEREIN OR
51-1OWN ON THE ACCOMPANYING DRAWINGS. THIS CONTRACTOR I5
RESPONSIBLE FOR CONNECTING TO THE LANDLORD'S FIRE
ALARM SYSTEM. COORDINATE WITH LANDLORD'S FIRE ALARM
CONTRACTOR AND SPRINKLER CONTRACTOR.
MODIFY THE EXISTING SPRINKLER SYSTEM IN THIS AREA FOR
THE CHANGES BEING MADE.
D. INCLUDE ANY MINOR ITEMS OF WORK NECESSARY TO PROVIDE A
COMPLETE AND FULLY OPERATIVE FIRE PROTECTION SYSTEM.
THE FIRE PROTECTION CONTRACTOR SHALL BE RESPONSIBLE
FOR DETERMINING THE EXACT I -AZARD CLASSIFICATION, AS
WELL AS THE QUANTITY, SPACING, AND PROTECTED AREA
LIMITATION OF SPRINKLER HEADS. CONTRACTOR SHALL
FURTHER BE RESPONSIBLE FOR CONFIRMING HIS DETERMINATION
WITH THE OWNER'S INSURING AGENCY AND THE LOCAL FIRE
AUTHORITY HAVING JURISDICTION OVER THE PROJECT.
WHERE APPLICABLE, LOCATE SPRINKLER HEADS IN CENTER OF
CEILING TILE, USE ARMOVER ON ALL SPRINKLER BRANCH LINES
TO ACCOMPLISH EXACT LOCATION OF HEAD.
PROVIDE AN NFPA -13 APPROVED AUTOMATIC FIRE SPRINKLER
SYSTEM IN BUILDING. SYSTEM SHALL BE APPROVED BY THE
LOCAL AND STATE FIRE MARSHAL'S OFFICE.
THE INSTALLING CONTRACTOR SHALL BE LICENSED AND
CERTIFIED IN THE INSTALLATION OF AUTOMATIC SPRINKLER
SYSTEMS IN THE STATE OF WASHINGTON.
11415 CONTRACTOR SHALL OBTAIN AND PAY FOR ANY
INSPECTION FEES, CHARGES, AND ANY OTHER GOVERNMENTAL
FEES APPLICABLE.
THIS CONTRACTOR SHALL FILE ALL NECESSARY DRAWINGS,
SPECIFICATIONS, CONTRACTOR'S MATERIAL AND TEST
CERTIFICATES_
K. THIS CONTRACTOR SI -IALL OBTAIN A CERTIFICATE OF
INSPECTION AND APPROVAL AND SUBMIT TO THE ARCHITECT
PRIOR TO THE REQUEST FOR FINAL PAYMENT.
11415 CONTRACTOR SHALL PROVIDE ALL PRODUCTS AND LABOR
REQUIRED TO COMPLETE THE INSTALLATION OF ALL FIRE
PROTECTION SPRINKLER SYSTEMS.
M. FIRE PROTECTION PIPING AND EQUIPMENT LAYOUT SHALL BE
COORDINATED WITH ALL EQUIPMENT, BOTH KNOGEI AND
UNKNOWN, AND EQUIPMENT INCLUDED UNDER OTHER DIVISIONS
OF THE SPECIFICATIONS.
ALL FIRE PROTECTION PIPING SHALL BE INSTALLED AS
CONCEALED WORK, WHERE APPLICABLE_
0. THE ARCHITECT RESERVES THE RIGHT TO CHANGE THE
LOCATION OF ANY SPRINKLER HEAD DURING THE SUBMITTAL
PROCESS EVEN IF THE MOVE SHOULD REQUIRE ADDITIONAL
HEADS.
P. FILL ANNULAR SPACE BETWEEN SLEEVE AND PIPE OR
INSULATION ON ALL PENETRATIONS THROUGH FIRE RATED
WALLS. FIRM- MATERIALS SHALL BE UL CLASSIFIED
AND MEET THE REQUIREMENTS OF ASTM. THE METHOD OF
INSULATION SHALL CONFORM TO UL FIRE RESISTANCE
DIRECTORY.
Q. CEILING GRID SYSTEMS SHALL NOT BE USED TO SUPPORT FIRE
PROTECTION ITEMS, PIPING, OR ANY OTHER EQUIPMENT. EACH
UTILITY AND THE CEILING GRID SYSTEM SHALL BE A SEPARATE
INSTALLATION AND EACH SHALL BE INDEPE AND3ITLY SUPPORTED
FROM THE BUILD:NNG STRUCTURE. K4ERE INTERFERENCE OCCURS,
IN ORDER TO SUPPORT EQUIPMENT OR CEILING GRID SYSTEM,
THE CONTRACTOR MIST INSTALL TRAPEZE TYPE MANGERS OR
SUPPORTS 1 4101 SHALL NOT BE LOCATED +'44ERE THEY
INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, LIGHT
FIXTURES, AND OTHER MECHANICAL OR ELECTRICAL ITS.
R. INSTALL ALL SPRINKLER HEADS IN ROOMS IN AN EST14EETIC
MANNER. SPRINKLER A.RRANGSIDIT SHALL BE PARALLEL AND
PERPcDIDIGULA.R TO THE BUILDING WALLS. COORDINATE WITH
ARCHITECT AND TENANT.
5. THE CONTRACTOR WALL VERIFY THE LOCATION GF UTILITIES
AND NOTE CONDITIONS 104I101 WOULD AFFECT a f,E W R:<_ ALL
DISCREPANCIES ~..HALL THEN BE REPORTED TO TI+E LANDLORD'S
TENANT COORDINATOR PRIOR TO THE BID As' P.RD.
T.
U.
V.
INSTALLATION IN; LL NOT BE CONi51DERED COMPLETE LANLESS AND
UNTIL WRITTEN ACCEPTANCE 15 RECEIVED FR al Ti}E STATE FIRE
MARSHAL AND 114E LANDLORD'S INSt,Ri G AGENCY.
CONTRACTOR TO MAINTAIN GE SET OF CRAi. PGS ON T44E -E .X6
TO BE USED STRICTLY RiCTLY FOR RECORDING ANY INSTALL.ATtON
DEVIATIONS FROM THE CONTRACT DRAWINGS.
THE FIQE PRGTECT4E1 CONTRACTOR is RESPO,SBI..E FOR DAILY
CLEAN -UP AND REMOVAL GF FIRE PRO T E I :ON C B :S FROM THE
SITE 'Ii. =EKLY- Tr.E PRS'.ISES SHALL BE KEFrT ICs A ? E. T AND
ORDERLY CONDITION.
W. T ;S CONTRACTOR S4ALL. REEVVE" AND FOLLOW ALL LANDLORD
REOUi:RDTENTS. T rE 5 /i T :`G A 5.D A I T O' A T ,C A..LY
I: WL:ES THAT TIESE REQGCRE ENiS HAVE BEEN REV.ENED ANsD
ARE IN THE B PRiC.E AND twGR.: LANDUR. D IN ADVANCE OF
ANY SYSTEM DON N TIM.
15413 SHOP DRAWINGS
A. THE CONTRACTOR SHALL SUBMIT FOR THE ARCHITECT'S AND
LANDLORD REVIEW SIX (6) COMPLETE COPIES OF THE CATALOG
DATA AND /OR SHOP DRAWINGS FOR THE LISTED ITEMS OF
EQUIPMENT AND ALL COMPONENTS TO BE USED IN THE WORK,
INCLUDING SPECIFIC PERFORMANCE DATA MATERIAL
DESCRIPTION, RATING, CAPACITY, WORKING PRESSURE,
MATERIAL GAUGE OF THICKNESS, BRAND NAME, CATALOG
NUMBER AND GENERAL TYPE. THE SUBMISSION SHALL BE
COMPILED BY THE CONTRACTOR AND REVIEWED BY THE
ENGINEER BEFORE ANY OF THE EQUIPMENT 15 ORDERED (AS
REQUIRED).
B. WHEN SUBMITTED FOR THE ARCHITECT'S REVIEW, SHOP
DRAWINGS SHALL BEAR THE CONTRACTOR'S CERTIFICATION
THAT THEY HAVE REVIEWED, CHECKED AND APPROVED THE
5140P DRAWINGS, THAT THEY ARE IN HARMONY WITH THE
REQUIREMENTS OF THE PROJECT AND WITH THE PROVISIONS OF
THE CONTRACT DOCUMENTS AND THAT THEY HAVE VERIFIED
ALL FIELD MEASUREMENTS AND CONSTRUCTION CRITERIA,
MATERIALS, CATALOG NUMBER AND FIELD MEASUREMENTS AND
SIMILAR DATA. CONTRACTOR SHALL ALSO CERTIFY THAT THE
WORK REPRESENTED BY THE 514OP DRAWINGS IS RECOMMENDED
BY THE CONTRACTOR AND THE CONTRACTOR'S GUARANTEE
WILL FULLY APPLY.
C. ALL CONTRACTORS SUBMITTING PROPOSALS FOR THIS WORK
SHALL FIRST EXAMINE THE SITE AND ALL CONDITIONS THEREIN.
ALL PROPOSALS SHALL TAKE INTO CONSIDERATION ALL SUCH
CONDITIONS AS THEY MAY AFFECT THE WORK UNDER THIS
CONTRACT. THE SUBMITTING OF A BID AUTOMATICALLY IMPLIES
THAT 11415 EXAMINATION OF THE SITE ItAS BEEN DONE.
15417 TESTS
A. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TESTING OF
SPRINKLER PIPING PER NFPA.
B. TEST SPRINKLER PIPING WITH A HYDROSTATIC TEST AT 200
PSI FOR 2 HOURS WITH NO VISIBLE LEAKAGE.
C. TEST ALARMS, FLOW SWITCHES, AND TAMPERPROOF
SWITCHES AND ADJUST AS NECESSARY.
15426 INTERIOR PIPE TUBE AND FITTINGS AND SPRINKLER HEADS
A. SPRINKLER HEADS:
B. PIPING:
C. SPRINKLER SPACING SHALL NOT EXCEED 130 5Q. FT. IN
'SALES' AREAS AND 100 5Q. FT. IN 'STOCK' AREAS. COMPLY
WITH LANDLORD'S DESIGN CRITERIA PIPE SIZING SHALL BE
BASED ON NFPA ORDINARY HAZARD.
D.
1. SPRINKLERS
2. VALVES
3. TAMPER SWITCHES
4. WATER FLOW SWITCHES
5. HYDRAULIC CALCULATIONS
6. CONNECTIONS TO LANDLORD'S FIRE ALARM SYSTEM
1. ALL SPRINKLER HEADS SHALL BE NEW U.L., F.M. LISTED
AND APPROVED AUTOMATIC SPRAY TYPE AS
MANUFACTURED BY CENTRAL SPRINKLER CO., GLOBE,
SIMPLEX GRINNELL, RELIABLE, STAR, OR VIKING.
2. ALL SPRINKLER HEADS SHALL BE RATED FOR 165'F UNLESS
INDICATED OTHERWISE ON DRAWINGS OR REQUIRED BY
LOCAL CODES.
3. VERIFY HEAD TYPES AND COLORS WITH THE TENANT AND
SUBMIT WITH SPRINKLER DRAWINGS FOR PERMIT.
1_ SCHEDULE 40, BLACK STEEL PIPE, ASTM A -53 FOR
FERROUS PIPING, WELDED AND SEAMLESS, ANSI
B- 36 -10 -70 FOR WROUGHT STEEL PIPE.
2. CAST IRON OR MALLEABLE IRON SCREWED FITTINGS FOR
PIPES 2 INCHES AND SMALLER. SCREWED OR CAST IRON
FLANGED JOINTS FOR PIPES LARGER THAN 2 INCHES.
3. GALVANIZED OR BLACK MALLEABLE IRON WITH BRASS SEAT
SCREWED UNIONS FOR PIPES 2 INCHES AND SMALLER.
4. VICTAULIC TYPE COUPLINGS ARE ACCEPTABLE, WHERE
APPROVED BY CODE AND THE LANDLORD.
5. HANGERS SHALL COMPLY WITH LANDLORD AND CODE
REQUIREMENTS.
WHERE POSSIBLE, REWORK THE EXISTING SPRINKLER SYSTEM
TO MEET THE NEW REQUIREMENTS OF 1 DESIGN.
E. PROVIDE AND INSTALL A VALVED TEST CONNECTION IN AN
ACCESSIBLE LOCATION FOR THE SPRINKLER SYSTEM AS
REQUIRED OR REQUESTED BY THE LANDLORD, LOCAL INSPECTOR,
OR IPISURANCE CARRIER.
F. TIES CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE
CAUSED BY LEAKS IN ANY OF THE EQUIPMENT INSTALLED BY
HIM. ALL REPAIRS OR REPLACEMENT OF DAMAGES SHALL BE AT
THIS CONTRACTOR'S EXPENSE.
G. PROPERLY COMPLETED AND SIGNED * SPRINKLER CONTRACTOR'S
MATERIAL AND TEST CERTIFICATES' SHALL BE FURNISHED TO
THE LANDLORD, AND AUTHORITIES HAVING JURISDICTION.
15430 SPRINKLER PIPING SPECIALTIES
A. PROVIDE ALL NECESSARY DRAINS_ COORDINATE THE EXACT
LOCATION WITH THE ARCHITECT AND LANDLORD PRIOR TO ANY
INSTALLATION.
1
1)1
,., RE-1 1+..".. FD ,-i
a ` a 4 ...
° - J , •
t•_iiED
OF !1 Tiiimituk
;W 1- •
1 PEP #7CFm7ER
1
z
3
o
ra Io
vi
M b
a $
0 a
e0
ti a
COdi
S S
3
cn 9 - k
P6.1
7
W
12
H
0
•
t►! nlocfor+wsunse: newowectvot
I.AHL:.vroR *WIERA Sfat saw
WCIAO►'+ON wi! MIR 1140•1108 ue;
WM AO MOM 1.11E WNW A AMI
wensilEraoa! SWAIDOESCIL
SAf I d?1M
DRAWING MJMft
1 >]