HomeMy WebLinkAboutPermit PG07-296 - WESTFIELD SOUTHCENTER MALL - RACHA THAI AND ASIAN KITCHENRACHA THAI &
ASIAN KITCHEN
1150 SOUTHCENTER MALL
PGO7-296
Parcel No.:
Address:
Suite No:
Tenant:
Name:
Address:
Owner:
Name:
Address:
Value of Plumbing /Gas Piping:
Fees Collected:
Urinals
Water Closet
Cityf Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
6364200010
1150 SOUTHCENTER MALL TUKW
RACHA THAI & ASIAN KITCHEN
1150 SOUTHCENTER MALL , TUKWILA WA
WEA SOUTHCENTER LLC
11601 WILSHIRE BLVD , LOS ANGELES CA
Contact Person:
Name: ELIZABETH MONTGOMERY
Address: 1405 BOYLSTON AV , SEATTLE WA
Contractor:
Name: WEST COAST PROPERTY MAINTAINENCE
Address: 12518 NE 163 ST , WOODINVILLE WA
Contractor License No: WESTCPMO27PO
DESCRIPTION OF WORK:
PROVIDE ALL PLUMBING TO KITCHEN AND RESTROOMS AND GAS PIPING TO ALL COOKING
EQUIPMENT
$33,000.00
$751.00
Plumbing
Bathtub or combination bath/shower 0
Bidet 0
Clothes washer, domestic 0
Dental unit, cuspidor 0
Dishwasher, domestic, with independent drain
Drinking fountain or water cooler (per head)
Food -waste grinder, commercial
Floor drain
Shower, single head trap
Lavatory
Wash fountain
Receptor, indirect waste
Sinks
FIXTURE TYPE AND OUANTITY
* *continued on next page **
PLUMBING /GAS PIPING PERMIT
Permit Number:
Issue Date:
Permit Expires On:
Phone:
Phone: 206 - 322 -4323
Phone: 425 - 488 -6045
Expiration Date: 09/28/2008
PG07 -296
02/01/2008
07/30/2008
Uniform Plumbing Code Edition: 2006
International Fuel Gas Code Edition: 2006
Plumbing (cont.)
Building sewer and each trailer park sewer 1
Rain water system - per drain (inside bldg) 1
Water heater and/or vent 2
Industrial waste treatment interceptor, including
0 its trap and vent, except for kitchen type
0 grease interceptors 0
1 Repair or alteration of water piping and/or water
2 treatment equipment 0
0 Repair or alteration of drainage or vent piping 0
3 Medical gas piping system serving (1 -5)
0 inlets /outlets for a specific gas 0
8 Medical gas piping (6 +) inlets /outlets 0
11 Gas Piping
1 Gas piping outlets (0-5) 5
5 Gas piping outlets (6 +) 12
doc: UPC /06 PG07 -296 Printed: 02 -01 -2008
Signature:
Print Name:
doc: UPC -10/06
City o`rTukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Permit Center Authorized Signature: A ` _ " - Date: -' _0 (J
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this plumbing /gas piping permit.
Date:
Permit Number: PG07 -296
Issue Date: 02/01/2008
Permit Expires On: 07/30/2008
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PG07 -296 Printed: 02 -01 -2008
Parcel No.: 6364200010
Address:
Suite No:
Tenant:
doc: Cond -10/06
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
1150 SOUTHCENTER MALL TUKW
RACHA THAI & ASIAN KITCHEN
1: ** *PLUMBING AND GAS PIPING * **
PERMIT CONDITIONS
13: * * * * * * ** PUBLIC WORKS * * * * * * **
All grey water shall be routed through the grease interceptor.
All brown water shall connect to sanitary side sewer and not to the grease interceptor.
* *continued on next page **
Permit Number:
Status:
Applied Date:
Issue Date:
PG07 -296
ISSUED
11/02/2007
02/01/2008
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R-3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to
twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill,
frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
PG07 - 296 Printed: 02 -01 -2008
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the performance of work.
doc: Cond -10/06
Date: l°
PG07 -296 Printed: 02 -01 -2008
Site Address: l 1 02 -^ ' tvlet ( I
Tenant Name:
Property Owners Name: W QS +PI Q 14 i G1
Mailing Address: ( 1 (b ( W t ] S Ot- ;alai `t'n+ w ✓
Name: I i t.eAlt e1, kovti-r -0 . 4 ",
Mailing Address: 19 o S 80 S A V
E -Mail Address: IA l G@ Coif CLt 01.0(i0
Contact Person:
E -Mail Address:
E -Mail Address:
CITY OF TUKWIL
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://wwwcitulcwila.wa.us
I ll N41) ►0.�
E -Mail Address:
Q:tAppliations\Forms- Applications On Line\3 -2006 - Permit Application.doc
Revised: 9 -2006
bh
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
King Co Assessor's Tax No.: et) (o y oZ b - 01) 1 O
Suite Number: Floor:
New Tenant: ^,® .... Yes ❑ ..No
lap ac
City
City
- Fax Number:
State
State
Zip
CONTACT PERSO --- who do we contact when your permit is ready to be issued
Day Telephone: (2oG) 3 -q ? a 3
ti4_ 1W41, /V22
State Zip
GENERAL CONTRACTOR INFORMATION -
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5
Company Name:
Mailing Address:
city
Day Telephone:
Fax Number:
Contractor Registration Number: Expiration Date:
Zip
ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record
Company Name:
Mailing Address:
Contact Person:
City State Zip
Day Telephone:
Fax Number:
ENGINEER OF RECORD - All plans must be et stamped by Engineer of .Record
Company Name:
Mailing Address:
Zip
Contact Person:
City
Day Telephone:
Fax Number:
Page 1 of 6
Valuation of Project (contractor's bid price): $
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm
Q:\Applications\Forms- Applications On Linel3 -2006 - Permit Application.doc
Revised: 9 -2006
bh
❑. None
Existing Building Valuation: $
Scope of Work (please provide detailed information):
Will there be new rack storage? ❑.... Yes ❑ .. No If yes, a separate permit and plan sub r • .1 will be required.
PLANNING DIVISION:
Single family building footprint (are f the foundation of all structures, plus any decks over 1 'nches and overhangs greater than 18 inches)
*For an Accessory dwelling, prov' the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documental' - that shows that the principal owner lives in one of the dwellings as his s her primary residence.
Number of Parking Stalls ' ovided: Standard: Compact: Handicap:
Will there be a change • use? ❑ Yes ❑ No If "yes ", explain:
❑ Other (specify) -
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
Page 2 of 6
Fixture Type: '
Qty
Fixture Type:
Qty
Fixture Type:
yP , '
'Qh'
Fixture Type:
-
Qty
Bathtub or combination
bath/shower
Drinking fountain or water
cooler (per head)
Wash fountain
Gas piping outlets
( 3
Bidet
Food -waste grinder,
commercial
i
indirect
waste
v
0
Clothes washer, domestic
Floor drain
a
Sinks
( (
Dental unit, cuspidor
Shower, single head trap
Urinals
Dishwasher, domestic,
wi ent drain
Lavatory
Water Closet
Building sewer r trailer
I
Rain water system — per
drain (inside building)
I
Water heater and/or
vent
z
Additional medical gas
inlets/outlets — six or more
p t sewer
Industrial waste
pretreatment interceptor,
including its trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of water
piping and/or water treating
equipment
Repair or alteration
of drainage or vent
piping
Medical gas piping system
serving one to five
inlets/outlets for specific gas
PLUMBING AND GAS PIPIN "ERMT"' INFOR1 ` T_ 206-43,,
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name:
Mailing Address:
3cI 0 S ou_y
Contact Person: DAM STS ( N (
E -Mail Address:
Contractor Registration Number: PLDj S I N OD3SL
Valuation of Plumbing work (contractor's bid price): $ L (O t'
Valuation of Gas Piping work (contractor's bid price): $ — 7 I �D 1 �/ /
Scope of Work (please provide detailed information): Ore i q � 11 f LON 1nj k I Ol
4 &i
gkYb � S n ;Tors dbf q I( I1 to i e-✓1f
Building Use (per Intl Building Code):
Occupancy (per Intl Building Code):
Utility Purveyor: Water:
5eA 1
City
Day Telephone:
Fax Number:
Expiration Date:
Sewer:
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
State Zip
— Sce cf so CR
Q:1Appliations\Fonna- Applications On Line13 -2006 - Permit Application.doc
Revised: 9 - 2006
bh
Page 5 of 6
,PERMIT .APPLICATION N01 APPhcab
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWN R AUTIO ' ED AGENT:
Signatur . /its /
Print Name: f a d qy (rvt e t h
Date: j
Day Telephone:
Mailing Address:
City
State
Zip
Date Application Expires:
I Date Application Accepted:
Q:Wpplications\Forms- Applications On Lineu -2006 - Permit Application.doc
Revised: 9 -2006
bh
Staff Initials:
Page 6 of 6
City of Tukwila
Parcel No.: 2623049023 Permit Number: PG07 -296
Address: 633 SOUTHCENTER MALL TUKW Status: PENDING
Suite No: Applied Date: 11/02/2007
Applicant: RACHA THAI & ASIAN KITCHEN Issue Date:
Receipt No.: R07 -02413 Payment Amount: $751.00
Initials: WER Payment Date: 11/02/2007 04:31 PM
User ID: 1655 Balance: $0.00
Payee: THAI FOODS INTERNATIONAL
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
TRANSACTION LIST:
Type Method Description Amount
Payment Check 2069 751.00
ACCOUNT ITEM LIST:
Description
GAS - NONRES
PLAN CHECK - NONRES
PLUMBING - NONRES
Account Code Current Pmts
000/322.100
000/345.830
000/322.100
172.00
140.00
439.00
Total: $751.00
doc: Receiot -06 Printed: 11-02 -2007
roject:
gaih 1I
Pl e1/4
Type of Inspection: /yam
(,` s 1 ' ..,-, l
ddress:
IP th //
Date Called:
Special Instructions:
Date Wanted:
a.m.
p.m.
Requester:
Phone No:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
(Inspector:
X60? -21 �
PERMIT NO.
ID Approved per applicable codes. El Corrections required prior to approval.
COMMENTS: 0A
•
.F
1 « <,.. d(.4.1-1 t2? ro 9/1,, P pee
Date:
��
El $60.00 REINSPECTIQN FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 10t Call to schedule reinspection.
COMMENTS:
Type of Inspection:
f T I /9 /�,, .
�[ /;S t 'o"/ 4" I / /rf 4 lido" )
fJ cfc 16,-- CI, l , /I/ 7 7 ? . Cl/ c ( C
T ,1 r7 : I G- Pic,-vyeh 44 6 -.2 ob
Special Instructions:
Date Wanted:
7 — /
p.m.
Requester:
Phone No:
226 30 FI/2 O
Not" r IT
Project:
/?c6& Th' '
Type of Inspection:
f T I /9 /�,, .
Address:
IW? M4/l
Date Called:
Special Instructions:
Date Wanted:
7 — /
p.m.
Requester:
Phone No:
226 30 FI/2 O
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION 12 1
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -
®Approved per applicable codes. El Corrections required prior to approval.
'Date: 47_
ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
'Inspector:
'Receipt No.:
'Date:
COMMENTS:
(ALIK 1 .1-113 T. r/vo,
ii4kr Q 1w 5 To (Ic HP iJ tt ti tko.n /20 °F
Poor :2. ✓i , I 1 t; lit r4-54 v f k Ff oo r
/ t
1fte ST.nt1,.5 S:4-115 1j Ld A ,,rtes' -s -/1 To Wr1
5 n fec( Ta PI 1...t4 14- IA =r : p r A Ill :;9
c:AL.0 n t(J 7o nr <f;vt Fi& ly (11 d 5:h,fct7 ous
or ets7roorl >7
Sink) 14 ted Ta ,k-t ,!1 b /1,# G cold 1 ,4 re -
Project:
12.6 c i t T` '
Type of Inspection: )
r .. vin i f 0/1 i \,l
Address:
11511 f tail
Date Called:
Special Instructions:
Date Wanted:
G - 3V — c4
Requester:
24-35 1120
Phone No:
Approved per applicable codes.
'Inspector:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
P6 -07 -a f '
PERMIT NO.
R
El Corrections required prior to approval.
Date: OPP
O � �
❑ $60.00 INSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
'Receipt No.: 'Date:
Pr ct: _
tc\ 1H r.Si
Type of Insppe�ction:
,,
1N ii'i — CAS
Address:
k1.t'3 m0L
Date Called:
Speci Instructions:
Dat, Wanted: _ {�
CO Z J — O(
a.m
p.m.
Requester:
Phone o• -Oa()
:2L)( 3S ?�
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION 1Z
6300 S outhcenter Blvd., #100, Tukwila, WA 98188 (206431 -3 7
JJ Approved per applicable codes.
COMMENTS: 0/c
Inspector:
Corrections required prior to approval.
i $60.perxEINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
'Receipt No.:
(Date:
rate:
- 2$ '6
Proj
W.t: 0 hA 14 A
Type of Inspection:
ev r( IA - 1
Address:
1i' )Wv
Date Called:
pecial Instructions:
Date Wanted: m�
5 q 7- p.m.
Requester:
Phone No -- E- el20
LI
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Approved per applicable codes. 13Corrections required prior to approval.
COMMENTS:
N2 / r /2/, S
Inspector:
Date:
$58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection.
(Receipt No.:
'Date:
COMMENTS: / 1 i
' Gc1rn -
0 61/0/ 4A(.0 2-- �
7,4sig4,
no /2-,;ti 4ppr eie
Address:
// 5 4 14 - 1/
/7,40-,F;g-0,-,19-ye*,<511,611/K14,4
. Ate,- "9-//auoiJ
Special Instructions:
Date �
27ed: ` I Oe
�y -
Requester:
Phone No:
,Pr9je Nff 4-S- ,
Type of Inspection: j)-, V
Address:
// 5 4 14 - 1/
Date Called:
Special Instructions:
Date �
27ed: ` I Oe
�y -
Requester:
Phone No:
Approved per applicable codes.
Corrections required prior to approval.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
1 Rece',t No.:
REINSPECTION FEE RI~QUIRED. Prior to inspection, fee must be
d 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection.
'Date:
.. j
Pr ct: 1r S1
Type °�10 AWCV (13CV
AddresA;,_
I(50 591N,'-{14...e £J -a
D to Called:
.4-`if
Special Instructions:
Date Wa ted:
3 ^ l O — v P;
. m.
ty
Requester:
Phone No:
INSPECTION RECORD
Retain a copy with permit ��
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION 'R'
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
M Approved per applicable codes. D Corrections required prior to approval.
COMMENTS:
Ain %f I " 5 7 — 4 / 67t4
Nv ?f ; ,51(4/ re"- ' -' / '� �7'w'
zl y
"� /`� y
.00 REINSPECTION FEE REQ ' ED. P for to inspection. fee must be
aid at 6300 Southcenter Blvd.. S to 10 Call the schedule reinspection.
(Receipt No.:
Date:
'Date:
.. _. �.: .o:.:`
Project:
I2aeke, (VA
Type of Inspection:
(/6- $G / //Y` L-f
Address:
166' 5- ,,41trt ,i1, re/l
Date Called:
3 - G -
Special Instructions:
_
Date Wanted:
3 -? -)f5
a.m.
p.m.
Requester:
koti
Phone No:
Z 75 S(.ZO
Ei Approved per applicable codes.
Inspector::
P6-Q72lb
INSPECTION RECORD
Retain a ropy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Corrections required prior to approval.
COMMENTS:
1 Sc pP /*, (Aar- 77.5 I`�,�I Ss �r' •
'Date:
Ei $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection.
(Receipt No.:
'Date:
l TI /A/ 9 /TJI
T I t N � 4vve ��.
j�J/
Ad ress:
/ ? sb/aAFti,k'.
Date Calle
()1 ,q -<
Special Instructions:
Date Want j�/ � a,m,
Requester:
Phone o:
a 33.E - 8i20
I
Inspector:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
PERMIT NO. /
(206)431 -36
Approved per applicable codes. ® Corrections required prior to approval.
COMMENTS:
k
El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection.
Receipt No.:
'Date:
Date:
December 19, 2007
City of Tukwila
Department of Community Development
Catch Design Studio
1405 Boylston Ave
Seattle, WA 98122
Re: Correction Letter #1
Plumbing /Gas Piping Application Number PG07 -296
Racha Thai & Asian Kitchen - 1150 Southcenter Mall
GENERAL NOTES:
1. Gas water heater will be replaced with electric, no longer applies
2. Connection is 6" this was a typo
3. See revised plans
PUBLIC WORKS DEPARTMENT COMMENTS
1. and 2. The water service is connected to the mall loop. Backflow prevention is provided by the mall
system, therefore no additional backflow is needed. As verified with discussions between Paul Johnson and
Michael P. Cusick.
3. The sheets that were referred to are labeled A3 and P3. and were submitted originally
4. Gravity flow, no pump required.
5. See revised plans
CORREViUN
LTR #�
RECEIVE!'
DEC 311007
PERMIT CENTE
December 5, 2007
Elizabeth Montgomery
1405 Boylston Ave
Seattle WA 98122
RE: CORRECTION LETTER #1
Plumbing/Gas Piping Application Number PG07 -296
Racha Thai & Asian Kitchen —1150 Southcenter Mall
Dear Ms. Montgomery,
This letter is to inform you of corrections that must be addressed before your plumbing permit can be
approved. All correction requests from each department must be addressed at the same time and
reflected on your drawings. I have enclosed comments from the Building and Public Works Department.
Building Department: Dave Larson, at 206 431 -3678 if you have questions regarding the
attached comments.
Public Works Department: Joanna Spencer at 206 431 -2440 if you have questions regarding the
attached comments.
Please address the attached comments in an itemized format with applicable revised plans,
specifications, and/or other documentation. The City requires that two (2) complete sets of revised
plans, specifications and/or other documentation be resubmitted with the appropriate revision
block.
In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every
resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person
and will not be accepted through the mail or by a messenger service.
If you have any questions, please contact me at (206) 431 -3670.
Sincerely,
7 NaAd 117-
Bill Rambo
Permit Technician
encl
xc: File No. PG07 -296
Cizy of Tukwila
P:\Perrnit CenteCorrection Letters\2007\PG07 -296 Correction Ltr #1.DOC
wer
Steven M Mullet, Mayor
Department of Community Development Steve Lancaster, Director
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
Building Division Review Memo
Date: December 4, 2007
Project Name: Racha Thai
Permit #: PG07 -296
Plan Review: Dave Larson, Senior Plans Examiner
Tukwila Building Division
Dave Larson, Senior Plan Examiner
The Building Division conducted a plan review on the subject permit application. Please address the
following comments in an itemized format with revised plans, specifications and/or other applicable
documentation.
(GENERAL NOTE)
PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size).
(If applicable) Structural Drawings and structural calculations sheets shall be original signed wet
stamped, not copied.)
1. There is a note on page P1 that reads heater vent up (load with upper tenant). If this means that the B-
Vents from your water heaters are to be tied into other vents in tenant spaces above your space,
section 801.19 of the IMC prohibits common venting of equipment located on different floors. If this
was not the intent, please clarify this note.
2. A section of grease waste is labeled as 8 inch and appears to tie into an existing 6 inch grease waste
line. This reduction in size would not be allowed per section 311.5 of the UPC unless you can show
how this connection is acceptable in another section of the plumbing code.
3. Our Public Works Department has reviewed your DWV plan and is requesting a new revised plan
that redirects fixture waste to either the grease waste or to the non - grease waste per City of Tukwila
standards. The Building Dept. will need this new plan as well to complete our plan review.
Should there be questions concerning the above requirements, contact the Building Division at 206 -431-
3670. No further comments at this time.
DATE: November 15, 2007
PUBLIC WORKS DEPARTMENT COMMENTS
PROJECT: RACHA Restaurant
Westfield Mall
PERMIT NO: PG07 - 296
PLAN REVIEWER: Contact Joanna Spencer (206) 431 -2440 if you have any questions
regarding the following comments.
1) Plumbing note #2 calls for pressure reducing valves and vacuum breakers. Number all backflows on
plan, provide a table listing all backflows, including size, manufacturer and model number. Make
sure that backflows are WA State Department of Health approved devices.
2) Provide schematic diagram(s) /detail(s) showing backflow installations.
3) Plumbing notes # 6 and 7 on plan sheet P1 refers to kitchen equipment and plumbing fixture
schedules, however none were submitted as part of this permit submittal.
4) If waste line connection to on site sewer line can not be reached by gravity flow, please submit pump
sizing calculations and pump(s) cut sheet.
5) Revise plan sheet P2 per attached mark -up, contact Mike Cusick, P.E., Public Works Senior Water
& Sewer Engineer at (206) 431 -2441 directly with questions. Please note that gray water from sinks,
floor drains, drains under garbage compactors shall be routed through the interceptor. DO NOT
route dishwashers through the grease interceptor.
(P:Joanna S /Comments 1 PG07 -296 PW)
ACTIVITY NUMBER: PG07 -296 DATE: 12 -31 -07
PROJECT NAME: RACHA THAI & ASIAN KITCHEN
SITE ADDRESS: 1150 SOUTHCENTER MALL
Original Plan Submittal
X Response to Correction Letter # 1
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS: 0 iir-08
Buis � : Di • n Ati
P Qrc Ii West, Iii
PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
Fire Prevention
Structural
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Planning Division
DUE DATE: 01 -03 -08
❑ Permit Coordinator
Complete Incomplete ❑ Not Applicable ❑
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route
Structural Review Required
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
Documents/routing slip.doc
2 -28 -02
❑ No further Review Required
Approved ❑ Approved with Conditions
Notation:
REVIEWER'S INITIALS: DATE:
DATE:
DUE DATE: 01 -24 -08
Not Approved (attach comments) I I
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments Issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑
Staff Initials:
ACTIVITY NUMBER: PG07 - 296 DATE: 11 -02 -07
PROJECT NAME: RACHA THAI & ASIAN KITCHEN
SITE ADDRESS: IP SOUTHCENTER MALL
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Issued
DEPARTMENTS:
Building � ` f�ivis n I
Public Wo Structural
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route
Documents/routing siip.doc
2 -28-02
PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
APPROVALS OR CORRECTIONS:
Fire Prevention
Incomplete ❑
Structural Review Required
REVIEWER'S INITIALS:
Planning Division
❑ Permit Coordinator
DUE DATE: 11 -6-07
Not Applicable
❑ No further Review Required
DATE:
DUE DATE: 12 -4 -07
n
Approved ❑ Approved with Conditions ❑ Not Approved (attach comments)
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only r
CORRECTION LETTER MAILED: t - S -0 7
Departments issued corrections: Bldg Er Fire ❑ Ping ❑ PW Staff Initials:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
Date: De C 1 2,e4 � 2 007 Plan Check/Permit Number: PG07 -296
❑ Response to Incomplete Letter #
® Response to Correction Letter # 1
❑ Revision # after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
Project Name: Racha Thai & Asian Kitchen
Project Address: 1150 Southcenter Mall
Contact Person: Elizabeth Montgomery
Summary of Revision:
11 em closed sGeo -f
Sheet Number(s): P 1 1 F 1 P3
"Cloud" or highlight all areas of revision including date of r exis
Received at the City of Tukwila Permit Center by:
Entered in Permits Plus on 1 -3f `D 7
\applications\forms- applications on line\revision submittal
Created: 8 -13 -2004
Revised:
Steven M. Mullet, Mayor
Steve Lancaster, Director
Phone Number: zv6 - 2 2 —
RECEIVE) r q,
3 1 10071
P FRMrt ciNT ,I4
License Information
License
WESTCPMO27PO
Licensee Name
WEST COAST PROPERTY MAINT
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
600323618
Ind. Ins. Account Id
#2
Business Type
INDIVIDUAL
Address 1
12518 NE 163RD ST
Address 2
City
WOODINVILLE
County
KING
State
WA
Zip
98072
Phone
4254886045
Status
ACTIVE
Specialty 1
GENERAL
Specialty 2
UNUSED
Effective Date
10/20/1998
Expiration Date
9/28/2008
Suspend Date
Separation Date
Parent Company
Previous License
Next License
Associated License
Bond Information
Bond
Bond
Company
Name
Bond
Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
#2
CBIC
SB6973
09/28/2001
Until
Cancelled
$12,000.00
07/10/2001
#1
CBIC
SB6973
09/28/1998
09/28/2001
$6,000.00
Business Owner Information
Name
Role
Effective Date
Expiration Date
CHIN, KON
OWNER
01/01/1980
Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2
Washington State Department of Labor and Industries
General/Specialty Contractor
A business registered as a construction contractor with L &I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= WESTCPMO27PO 02/01/2008
Ji
PROVIDE AIR
ADMITAMCE VALUE
UNDER COUNTER
2'V DN -
UNDERCOUN
REFRIGERAT
ELECTRIC STEAM TABLE
1/2" HW & CW DN
TO UNDER COUNTER
2 "V DN
( TYP)
OID
(0 -3)
120" WORK
TABLE
2 "V DN
(2Tw)
(D -2)
3/4'
2'V ON
2 TYP)
2" V DN
(E)3" V
ICE
MAKER
DIRTY DISHES LANDING
/2' HW & CW DN TO
BELOW COUNTER TO
19 & 23
1/2" CW TO
24 25 & 26
NOTE 8&9
2' VDH
(E) 3" COLD WATER SUPPLY
®FD
(0 -1)
2" VDN
NOTES 8&9
1 1/2"
REMOTE READOUT 0 4
WATER METER W /JUMPER NlRE
(E) P.D.0
2"V DN —,
� j 2•
HW
2 "VON
1- 1/2....
GW FCO
1/Y HW D
11/2" (P -4)
NOTE 9
3/4" HW&CW
(E)3' V
P.O.0
(2 TYP)
(P -4
NOTE
(P-3)
3 / 4 . . _
ELECTRICAL ROOM
FD
(0 -3)
(P -4)
NOTE 9
- 3" GAS
1 ISOLATION VALVE
0 5` A.F.F.
2 "VDN
HAND SINK
140
HW
1
FS
FTh ®
FCCZ
G
HW
r
(E)
0 —
c
L
PLUMBING SYMBOLS
1
FLOOR SINK, W/ 1/2 GRATE
FLUSH W/ FINISHED FLOOR
FLOOR DRAIN
FLOOR CLEANOUT
WALL CLEANOUT
GAS
COLD WATER
HOT WATER (TEMP)
HOT WATER RECIRC
VENT
BALANCE VALVE (SET AT 1 GPM TYP)
CHECK VALUE
BALL VALVE
THERMOMETER
EXISTING
PIPE UP
PIPE DN
HEAT TRACE
H
JL
2' V ON - --
JL IL JL J
HAND SUN
30
(
--NOTE 8 & 9
"VDN
1/2'
2" V DN
r �
1 TABLE
HW r H 11/
EMERGENCY GAS -z— —
SHUT OFF
(COORD.W /FIRE
SUPPRESSION SYSTEM)
(
2 " VON
ROUTE HOT & COLD
WATER UNDER
COUNTER
TO FIXTURES
1/2"
1/2"
G UP TO MAU
ON ROOF
cs
0
3/4'
HAND SINK
--NOTE 8 & 9
OISPIAYCIM
4 0 0
HW
1/2"
r
'.FCO
l/2"
TABLE
x
L W
014,
(5 TO
�FD
( -1 )
EMERGENCY GAS
SHUT OFF
(COORD.W /FIRE
SUPPRESSION SYSTEM)
(2 TYP)
78
GAS
FRYI
TRAP PRIMER --
3/4"
NOTES 8&9
2 "VDN
HAND SIN(
_-I
2' V
PROVIDE
WATER
HAMMER
ARRESTOR Y
2
I i L DISHWASHER
MINE
/2•HWDN
10
2'VDN
1 11
- VI C0
;> 1
(E) 3' G
POC
o
:
NOTE 8
ROUTE PIPING
UNDER COUNTER
TO FIXTURES
NOTE 8 & 9
PLUMBING NOTES
Piar review approval is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Field Copy and conditi.j - is ac
By
Cis
PLUMBING PLAN
SCALE 3/16" = 1' -0"
FILE COPY
Permit No.
Date:., - _ a
City of Tukwila
BUILDING DIVISION
1. PLUMBING PLAN SHOWS ROUGH -IN AND CONNECTION LOCATIONS WITH
DIMENSIONS AND CAPACITIES. PLUMBING CONTRACTOR RESPONISBLE
2. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL ALL NECESSARY
VALVES, TRAPS, TAIL PIECES, LINE STRAINERS, PRESSURE REDUCING
VALVES AND VACUUM BREAKERS AND CONNECT ALL WATER,
AND WASTE LINES TO FOOD SERVICE AND BEVERAGE EQUIPMENT.
3. PLUMBING CONTRACTOR SHALL INSTALL AND CONNECT ALL FAUCETS
FURNISHED WITH FOOD SERVICE AND BEVERAGE EQUIPMENT.
4. PLUMBING CONRACTOR SHALL FURNISH AND INSTALL ALL
INDIRECT WASTE LINES FROM FOOD SERVICE AND BEVERAGE EQUIPMENT
TO FLOOR DRAINS AND SINKS AND INSULATE WASTE LINES FROM
ICE BINS, EVAPORATORS AND BAIN MARIES.
5. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR ADA BATHROOM
COMPLIANCE AND WITH LOCAL CODE REQUIRMENTS, IF NEEDED
6. SEE KITCHEN EQUIPMENT LIST FOR CONNECTION SIZES
7. SEE PLUMBING FIXTURE SCHEDULE FOR CONNECTION SIZES
8. PROVIDE FILTER ON WATER SERVICE TO THIS FIXTURE
9. PROVIDE TEMPERING VALVE AT EACH SINK SET @ 110 c F
10. PROVIDE QUICK DISCONNECT ON ALL GAS APPLIANCES
11. PROVIDE SEISMIC SHUT -OFF VALUE DOWNSTREAM OF GAS METER IN
METER ALCOVE -COORD LOCATION W /MALL
CORRE0 TI0N
?Go7 29(o
6
;AEI -ABATE PERMIT'
N QUIRED FOR:
VI [III Electrical
O Plumbing
O Gas Piping
1 City of Tukwila
iffi .41_011.1G DIVISION
a
DEC 31 2007
- ER
@FAIVEC4
D E S I G N S T U D I O
PLATING AND FITERIOR DESIGN
1405 BOYLSTON AVE
SEATTLE, WA 98122
TEL. 206.321423
E" MALS FO*CATCHSTUDIO.COM
WWW.CATCHSTUDIO.COM
ENGINEER i p� � /t�/�
J BLACKLAW
7224 JAME8 M.
sW ROCHESTER WA 98579
KITCHEN DESICA
BAN ELUNGSON
36271 ST AVE SOUTH
SEATTLE ,WA 98134
PHONE= 206.6821472 FAX: 206.6822367
PROJECT TITLE
RAGA
IF AI & ASIAN Kit( 1[.N
WESTFE3.D MALL CTUCWLA, WA)
MEET TITLE
PLUMBNG PLAN
REVISIONS
PYTEFOR DESK*
CATCH DESIGN STUDIO
DRAWN PAUL W. JOFNSON, PE
DATE 12/26/07
SCALE AS NOTED
FLE
SHEET'
P1
PLUMBING FIXTURE UNIT CALCULATION
FIXTURE
QUANTITY
WATER FU/FWct.
CW
HW
WASTE FU/Fbd.
W
WATER CLOSET
5
23
115
4
20
URINAL
1
20
20
2
2
LAVS /HANDSINKS
14
2
28
21
1
14
MOP SINK
2
2
4
3
3
6
3-COMP SINK
1
4
4
3
2
2
2-COMP SINK
1
4
4
3
2
2
GLASS WASHER
1
1
1
0.75
IND
BAR
4
1
4
3
IND
PASTA COOKER
1
1
1
ICE MAKER
1
1
1
IND
DISHWASHER
1
10
7.5
10
10
BLENDER STATION
1
1
1
0,75
IND
FLOOR DRAIN
7
2
14
FLOOR SINK
8
2
16
TOTAL FU'S
183
42
86
3 „
140
HW
UP
NOM:
FS
FD
FCO0
T
HW
(E)
MALL PROVIDED KEY NOTES:
0 FOR CONTINUATION AND LOCATION OF MARSH GAS
INTAKE.
/1\ COORDINATE TERMINATION OF AIR INTAKE WITH aviL TYPICAL
0 4'W UP TO FLOOR CLEANOUT. CONNECT TO EXISTING 4' W
STUB- UP FROM MAIN SEWER BELOW.
03 4" RWL UP TO FLOOR CLEANOUT.
® 4" W FROM ABOVE.
05 4" W STUB -UP FOR FUTURE TENANT CONNECTION
0 4"W UP TO FLOOR CLEANOUT.
0 6" RWL UP.
0 4 "WUPT04
09 7' W UP TO 7'
CI 7'WUP.
11 7' VUP.
II
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
1�
11
1. HW DEMANDS BASED ON 75% OF CW DEMANDS PER UPC.
2. CW DEMANDS BASED ON FLUSH VALVE FIXUTR UN(IS.
3. DRAINAGE WASTE FU BASED ON TABLE 709.1 IPC.
PLUMBING SYMBOLS
FLOOR SINK, W/ 1/2 GRATE
FLUSH W/ FINISHED FLOOR
FLOOR DRAIN
FLOOR CLEANOUT
WALL CLEANOUT
GAS
COLD WATER
HOT WATER (TEMP)
HOT WATER RECIRC
VENT
BALANCE VALVE (SET AT 1 GPM TYP)
CHECK VALUE
BALL VALVE
THERMOMETER
EXISTING
PIPE UP
PIPE DN
HEAT TRACE
11
11
11
11
11
11
11
11
1 1 1
11
11
11
11
11
11
11
11
11
11
1
11
11
11
11
11
11
11
11
11
11
11
11
11
1 1
1 1
1 1
11
1
11
it
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
2 "W UP
TO FS
3" UP
TO WCO
n
3" UP
FCO
(38
2 "W UP TO
2 "W UP TO
1T
2 "W UP TO 14
11 1/2"W UP
TO FS
1 1 1/2"W UP TO FS
2 "V UP TYP.
(6 TYP)
3 "RL UP TO FD
2 "W UP TO FD
TRAP PRIMER
TOEAFD.,
11
2" W UP TO POT SINK
(3 TYP)
2 "W UP T Q
HAND SINK
FD 2 "W UP
(D-1)TO Fp
2 "W UP TO
FLOOR SINK
FS(D - 2)
H H
P.O.C.
1 1/2"W UP
TO FS
14"
2 "W UP TO
HAND SINK
4 "W UP TO FS (DW)
2 "V UP
4"
2 "W UP TO
6
TRAP PRIMERS
TO EA. FD
>>
PLUMBING FLAG NOTES
IE +24.50'
COORDINATE CONNECTION OF GREASE UNE TO LAND LORD
PROVIDED GREASE INTERCEPTOR. VERIFY LOCATION AT JOB SITE
WHERE GREASE INTERCEPTOR IS
V PROVIDE ELECTRICAL CONNECTION TO EXISTING HEAT TRACE ON GREASE
WASTE PIPE. (VERIFY LOCATION)
PROVIDE ELECTRIC HEAT TRACE @ 8W /FT. COORDINATE W/ ELECTRICAL
MOP
SINK
"W UP TO
3 "W UP TO
(P -5 )
P.O.C.
UP TO
WCO
6" GW
IE +24.50'
CONNECTION TO GREASE
INTERCEPTOR E
CLEANOUT #1
IE. IN
Ct \Fs(D' 2 )
O
\L
3REASE INT
MODEL: 6000
C.O. #1 IE: 19.89
IE IN: 19.85
IE OUT: 19.65
C.O. #2 IE:19.61
10"
n
1 2 "
1 UP TOC
2 "V UP
SCALE
RCEPTOR E
CLEANOUT #2
IE. OUT
3116` =1' -0"
C 1 ( 1i .
FOUNDATION PLAN
DEC 312007
D E S I G N S T U D I O
PLAN 1G A1D) INTERIOR DESIGN
1405 BOYLSTON AYE
SEATTLE, WA 98122
TEL 206.3224323
E-MAL O•CATCHSTUDIO COCA
WWW.CATCHS 1. DIO.COM
ENGINEER
BLACKLAW
7224 JAMES RD.
SW ROCHESTEF1 WA 98579
KffcHEN DESIGN
BARGREEN ELLIVGSON
36271 ST AVE. SOUTH
SEATTLE ,WA 98134
PHONE: 206.6821472 FAX: 206.6822367
PROJECT TITLE:
CHECKED
DATE
FLE
SIT'
SMET TITLE
WESTFIELD MALL CRKWLA, WA)
FOUNDATION PLAN
INTERIOR DESK
CATCH DESIGN STUDIO
DRAWN PAUL W. JOI-1ISON, P.E.
12/26/07
SCALE AS NOTED
P2
PLUMBING FIXTURE SCHEDULE
MARK
ITEM
MFR /MODEL
DESCRIPTION
COLD
WATER
(IN)
HOT
WATER
(IN)
WASTE
(IN)
VENT
(IN)
P -1
WATER
CLOSET
FLUSH
VALVE
AMERICAN
STANDARD
AFWALL 2257.103
SLOAN ROYAL
111 ES -S
WALL HUNG, VITREOUS CHINA,
ELONGATED BOWL, 1 -1 /2" TOP SPUD,
SIPHON JET
WATER SAVER FLUSH VALVE, CHROME
PLATED, SCREWDRIVER STOP, INTERGRAL
VACUUM BREAKER, VANDAL RESISTANT,
1.6 GPF.
1
-
4
2
P -2
WATER
CLOSET
SAME AS P -1
SAME AS P -1. EXCEPT MOUNTED
AT HANDICAPPED HEIGHT
1
-
4
2
P- 3
URINAL
FLUSH
VALVE
KOHLER
DEXTER
K- 5016 -ER
SLOAN
8186 -1.0
WALL HUNG, VITREOUS CHINA, SIPHON
JET ACTION, WHITE, 1.0 GPF
EXPOSED, BATTERY POWERED SENSOR
OPERATED, CHROME PLATED, INTERGRAL
VACUUM BREAKER, 1.0 GPF.
3/4
-
2
2
P- 4
LAVATORY
DRAIN
FAUCET
KOHLER
SAMBA
K -2605-M
KOHLER
K -771 5
KOHLER
K-10952-4
SELF RIMMING, 20 GAUGE STAINLESS
STEEL, MIRROR FINISH WITH
UNDERCOAT
NON - REMOVABLE GRID STRAINER,
CHROME TAILPIECE
THREE HOLE, DC ELECTRONIC
POLISHED CHROME, 0.5 GPM.
NOTE 2
1/2
1/2
2
2
D -1
FLOOR
DRAIN
J.R. SMITH
2005Y
DUCO CAST IRON BODY WITH FLASHING
COLLAR AND ROUND TOP ANTI -FLOOD
RIM, FLUSH WITH FLOOR, 7" DIA. STRAINER
WITH TRAP PRIMER
-
-
2
2
D - 2
FLOOR
SINK
(KITCHEN)
J.R. SMITH
3141 Y -12-C
CAST IRON FLANGED RECEPTOR WITH
ACID RESISTANT COATED INTERIOR,
SEDIMENT BUCKET, 6" DEEP, FLASHING
CLAMP AND NICKEL BRONZE RIM AND
1/2 GRATE
-
-
2
(NOTE (1)
1-1/2
D - 3
TERRACE
DRAIN
ZURN
A415B
DURA COATED CAST IRON BODY
WITH FLASHING COLLAR, ROUND NICKEL
BRONZE STRAINER HEAD, ADJUSTABLE
-
-
3
-
TRAP
PRIMER
VALVE
PPP
P -1 -500
MACHINED BRASS WITH
DITRIBUTION UNIT
1/2
WATER
HAMMER
ARRESTOR
PPP
SC -XXX
SIZE PER MANUFACTURERS
RECOMMENDATION
PLUMB NG FIXTURE SCHEDULE NOTES:
1) UNLESS OTHERWISE NOTED
2) PROVIDE MIXING VALVES TO LIMIT MAXIMUM HOT WATER TEMPERATURE OF 110- DEGREE F TO LAVATORIES
74
85
85
76
(2) 78
WOK
RICE
1
40
40
42
44
43
47
49
40
RANGE
RANGE
BROILER
GRIDDLE
FRYER
STOCK POT
PASTA
RANGE
220 MBH
220 MBH
120 MBH
60 MBH
110 MBH
180 MBH
53 MBH
220 MBH
74
85
85
76
(2) 78
WOK
RICE
RICE
FRYER
OVEN
137 MBH
34.6 MBH
34.6 MBH
122 MBH
240 MBH
HOT WATER
CIRC
CIRC PUMP
B &G PL -45B
10GPM /20FT HD
1 /6H P/120V/1 O
/iiwn
CW SERVICE
� HW TO FIXTURES
EXP TANK
AMTROL
ST -60V
1 1/4"
SEISMIC
RESTRAINT
(TYP)
DRAIN VALVE
7G)Ai< WATER HEATER DETAIL
T
41
IMMERSION - TYPE
AQUASTAT
WH
123
DRAIN TO FD
2 "W UP TO (
UP TO FCO
/ A
2 "W
WH
\ THERMOSTAT
\\ (TYP)
- - 1NSUL. PAD
N
r
1 1
1/2"W UP
I TO FS
RELIEF PIPE -FULL
SIZE TO
DRAIN PAA
v
2 "V
Ak
N.
2 "W UP TO FD
BALL VALVE (TYP)
T &P RELIEF VALVE (TYP)
0 .
1 1/2"W UP TO FS
2 "
N
N
ti
2 "W UP TO
1 4 I
1 1 1/2"v UP
I I /TO FS A
I I /
1
1
\ I 1 i
v
NT$
2 "W UP TO
FD
N
M
\1
J N
MAU
55
500 MBH
3"
2"
1 1/4" 1 - -1 1/4"
I J
1 2V
� I
3"GW
cp-
04 C 3*
2'V
I �
11
NTS
1 1/4"
MAU
79.1
500 MBH
2 "GW
2 "V
2 "W UP TO
HAND SINK
2 "W UP TO
/
F.D.
3/4"
HAND SINK
I 2 "V
x � 1
r
GAS PIPING RISER DIAGRAM
2 "W UP TO
»
ti
P.O.0
N.
WASTE & VET
2" ' 1 1 /2"
S•
3 "W
y
1 1/4"
'\c)
3/4"
P.O.C.
2 VP)
T DIAGRAV
1 1/4"
3 "GW
N,
< I - -2 "W UP TO
F.S.
(E) 3 V
J > P.O.0
3
2 "W UP.TO F.S.
\
I �
UP TO FCO
2 "(TYP) /
HAND SINK
3 "GW
2 » V
2" 1 1 /2"
1 1/2" 1 1/2"
J J
P.O.0
vi
1,
(E)4 ''
1
1 1 /4"
% AAV
0
ENTRY ROOF
IDGn, 29 (9
3"
3"
ISOLATION VALUE
IN UTILITY
CORRIDOR
`CEJ GAS SERVICE
P.O.C. 3,000MBH
MAIN FLOOR
DEC 31 ZUU1
D E S I G N S T U D I O
PLANNING AND tYFERIOR DESIGN
1405 BOYLSTON AVE
SEATTLE, WA 98122
TEL 206.322A323
E-MAL CATCHSTUDIO.COM
WWW.CATCHS1UDIO.COM
ENGINEER
JO141 BLACKLAW
7224 JADES RD
SW ROCHESTER WA 98579
PROJECT TITLE:
SIFT TRL
c
SCALE AS NOTED
FLE:
SHEETS
KITCHEN DESIGN
BARGf1EEN ELLINGSON
36271 ST AVE SOUTH
SEATTLE ,WA 98134
PHONE 206.6821472 FAX 206.6822367
Rg1M
CHAT & ASIAN XITOftN
wevearkockaciliazcom r
WESTF ELD MALL CTUKWI.A, WA)
WASTE+VENT DIAGRAM
GA8 PIPING RISER DIAGRAM
GAS WATER HEATHER DETAL
IfERIOR DESIGN
CATCH DESIGN STUDIO
DRAWN PAUL W. JOHNSON, PE
DATE: 10/26/07
P3