Loading...
HomeMy WebLinkAboutPermit PG07-349 - WESTFIELD SOUTHCENTER MALL - BANANA REPUBLICBANANA REPUBLIC 806 SOUTHCENTER MALL PGO7-349 Parcel No.: 6364200010 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Value of Plumbing /Gas Piping: Fees Collected: doc: UPC -10/06 Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 806 SOUTHCENTER MALL TUKW BANANA REPUBLIC 806 SOUTHCENTER MALL , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA DERRICK PRODIGALIDAD 13648 BURBANK BL , SHEARMAN OAKS CA Contractor: Name: OKITSU CONSTRUCTION INC. Address: 1428 WH1TWORTH AV S , RENTON WA Contractor License No: OKITSCI959L8 $10,000.00 $240.50 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet FIXTURE TYPE AND QUANTITY * *continued on next page ** PLUMBING /GAS PIPING PERMIT Permit Number: Issue Date: Permit Expires On: Phone: Phone: 818 786 -8960 Phone: 206 714 -9969 Expiration Date: 06/28/2009 DESCRIPTION OF WORK: (2) RESTROOMS WITH WC AND WASH SINKS INCLUDING INSTANT HOT WATER AND ELECTRIC WATER HEATER PG07 -349 04/02/2008 09/29/2008 Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 Plumbing (cont.) O Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 O Water heater and/or vent 1 O Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 1 grease interceptors 0 O Repair or alteration of water piping and/or water 1 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 2 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 0 Medical gas piping (6 +) inlets /outlets 0 0 Gas Piping 0 Gas piping outlets (0 -5) 0 2 Gas piping outlets (6 +) 0 PG07 -349 Printed: 04 -02 -2008 Permit Center Authorized Signature: Signature: Print Name: doc: UPC -10/06 City o Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read and e , . ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the p :t j ;• rmance of work. I am authorized to sign and obtain this plumbing /gas piping permit. Permit Number: PGO7 -349 Issue Date: 04/02/2008 Permit Expires On: 09/29/2008 Date: Date: be. ? ® � This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PG07 -349 Printed: 04 -02 -2008 1: ** *PLUMBING AND GAS PIPING * ** doc: Cond -10/06 City of Tukwila Parcel No.: 6364200010 Address: 806 SOUTECENTER MALL TUKW Suite No: Tenant: BANANA REPUBLIC Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: PGO7 -349 ISSUED 12/27/2007 04/02/2008 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. PG07 -349 Printed: 04 -02 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: GIL- fLy . tic }sue doc: Cond -10/06 PG07 -349 Date: I1e V. t o V ordinances governing or local laws regulating Printed: 04 -02 -2008 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: 'hrinr. ci. tubrila.ira. us Company Name: / ( f 1L r i 6 Mailing Address: 50 4 '. VG i / 57 Sir 7/0 Contact Person: K ' r Q'NAW' I'' E -Mail Address: i . &if Contact Person: Bill_ we.g. Q:1Appliations\Fams- Applications On Linel9 -2006 - Permit Appliationdoc Revised: 9-2006 bh Building Permit No. Q° 1 pct Mechanical Permit No. AA II� ' 1' Plumbing/Gas Permit No. e 4' -' l Public Works Perm' No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION A A King Co Assessor's Tax No.: ' 72 ` / 4 ° �l 519 1111 lint, ZA, Suite Number: Floor: Site Address: New Tenant: Yes ❑..No Tenant Name: `T (A4 ,, O-�` X ` � Property Owners Name: ES It D �RT7 n t (dF e Mailing Address: I' i 4 W I L5ZT l BLVA) w� Adag-E CA qet City state Zip CONTACT PERSON — who do we contact when your permit is ready to be issued `� Nam Lord `�' paw ' Day Tone: "�S� � Mailing Address: �� js V 'r✓v 1 e j , e- 4/ , C3I r i4k � A'. X41 GitY E -Mail Address: r f '���� �/�r � � .Fax Number: �)�'`�•7�} -g-9) GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: ." 1 — B0 Mailing Address: City Contact Person: Day Telephone: E-Mail Address: Fax Number. Contractor Registration Number: Expiration Date: State ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record f 52,19-/Iegee 9 M2 Day Telephone: s is Fax Number: 1 /$" Z B 9 ( ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: .67% am-0a74 /n�,, im a 1// V n, Mailing Address: 6,(6S V,4i R�r Ri) Ai 7732 Day Telephone: 512 ` S``. E -Mail Address: Fax Number: 92-7 74 - 4 / Page 1 of 6 BUILDING PERMIT INFOR)TION — 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 2 06: OW Existing Building Valuation: $ Scope of Work (please provide detailed information): AIM 7610W7 i i 7 IA) (t A % - N ", A t6— Fllr<l i r / /4/7a —Rze, Will there be new rack storage? Yes Q:1ApplicationsWonns- Applications On linen -2006 -Permit Appliatiandoc Revised: 9 -2006 bh ❑.. No If yes, a separate permit and plan s 'ttal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building foo .. ' :+ (area of the foundation of all structures, plus any decks ov 8 inches and overhangs greater than 18 inches) *For an Accessory dwell' provide the following: Lot Area (sq ft): Floor area of principal dwelling: *Provide doc '/- tation that shows that the principal owner lives in one of the dwellings s or her primary residence. Number of Par . t _ Provided: Standard: Compact: Will there be a c ' ge in use? ❑ Yes ❑ No If "yes", explain: Floor area of accessory dwelling: Handicap: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes If `yes , attach list of materials and storage locations on a separate 8 -1/2 "x 11 "paper including quantities and Material Safety No to Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 5 E k ing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC I" Floor ( 3782- V3 g Floor 3` Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFOR)TION — 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 2 06: OW Existing Building Valuation: $ Scope of Work (please provide detailed information): AIM 7610W7 i i 7 IA) (t A % - N ", A t6— Fllr<l i r / /4/7a —Rze, Will there be new rack storage? Yes Q:1ApplicationsWonns- Applications On linen -2006 -Permit Appliatiandoc Revised: 9 -2006 bh ❑.. No If yes, a separate permit and plan s 'ttal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building foo .. ' :+ (area of the foundation of all structures, plus any decks ov 8 inches and overhangs greater than 18 inches) *For an Accessory dwell' provide the following: Lot Area (sq ft): Floor area of principal dwelling: *Provide doc '/- tation that shows that the principal owner lives in one of the dwellings s or her primary residence. Number of Par . t _ Provided: Standard: Compact: Will there be a c ' ge in use? ❑ Yes ❑ No If "yes", explain: Floor area of accessory dwelling: Handicap: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes If `yes , attach list of materials and storage locations on a separate 8 -1/2 "x 11 "paper including quantities and Material Safety No to Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 5 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) ! Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain I Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory , Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent 1 Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets /outlets for specific gas PLUMBING AND GAS PIPING PERMIT INFORMATION - 206 -431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: 1 d�-� Mailing Address: City State Zip Contact Person: Day Telephone: E-Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ 10 Valuation of Gas Piping work (contractor's bid price): $ Scope of Work lease provide detailed information): )1cly 1. 1051 Ho c OT- h Building Use (per Int'l Building Code): ( Occupancy (per Int'l Building Code): 1014 Utility Purveyor: Water: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q: ApplicationsTonns- Applications On t.inen -2006 - Permit Appliation.doc Revised: 9 -2006 an Sewer: Page 5 of 6 BUILDING Rau n Signatut � PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the. Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. rar>r . Date Application Accepted: Q:WpplicationsWonns-Applications On Line\3 -2006 - Permit Appliation.doc Revised: 9 -2006 bh Date: I ZJ2 /© 7 Print Name: / e- / r;T ' � - C Day Telephone: 706 7g Mailing Address: 1340 s 0444 0 0A� �' _D 6A- 4 1) 4 city State Zip Date Application Expires: Staff Initials: Page 6 of 6 Doc: RECSETS-06 RECEIPT NO: R08 -01014 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http:/lvvww.ci.tukwila.wa.us Initials: JEM Payment Date: 04/02/2008 User ID: 1165 Payee: OKITSU CONSTRUCTION, INC. SET ID: 0324 SET NAME: BANANA REPUBLIC SET TRANSACTIONS: Set Member Amount M07 -292 417.96 PG07 -349 206.00 TOTAL: 623.96 SET RECEIPT Total Payment: 623.96 TRANSACTION LIST: Type Method Description Amount Payment Check 1636 623.96 TOTAL: 623.96 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLUMBING - NONRES Account Code Current Pmts 000/322.100 417.96 000/322.100 206.00 TOTAL: 623.96 RECEIPT NO: R07 -02863 Initials: JEM User ID: 1165 Payee: PERMIT PLACE, INC. SET ID: S000000928 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D07 -484 1,274.44 EL07 -808 184.50 M07 -292 82.49 PG07 -349 34.50 TOTAL: 1,575.93 TRANSACTION LIST: Type Method Description Amount Payment Check 7003 ACCOUNT ITEM LIST: Description City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: //www ci.tukwila.wa.us ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES SET RECEIPT TOTAL: Payment Date: 12/27/2007 Total Payment: 1,575.93 1,575.93 1,575.93 Account Code Current Pmts 000.345.832.00.0 184.50 000/345.830 1,391.43 TOTAL: 1,575.93 6533 12/27 9710 TOTAL 1575.93 Project: Q 4� ,ia ,' udl C Type of Inspection: ,c: ;�,� Address: G TYIA1 I Date Called: Special Instructions: Date Wanted: 7 i___ /3 A p. m Requester: Phone No: ,266 773 Z7/7 INSPECTION RECORD - . Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION CI- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: Fi /1AI c_ /1i1/7,f? / Approved per applicable codes. Corrections required prior to approval. 'Inspector: El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: - 407-3 'Date: 7/.5/4 9 Project: / ,(. G 134h#111 / y E J -' Type of Inspect n: " i f /4f4,M 7 Address: r @'(( nA (( Date Called: Special Instructions: Date Wanted: ` - 7-1- J a — i p.m. Requester: Phone No INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1?-- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 - 6 0 El Approved per applicable codes. Corrections required prior to approval. COMMENTS: _1)r0'-,-o/e /7sc /f /o... (., 4 , r (Inspector: J $60.06' EINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 Recelpt No.: 'Date: Date: ) - o 7 -3 ` (1 7--/- d Project: g istiodirok fie/X./Wit Type of Inspection: /22‘65i,'6, Address: a96 51L-fAr (dr" 1-1,1I Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone No: 2- 213 320 a z NI Approved per applicable codes. Pb 07 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 Corrections required prior to approval. COMMENTS: I 7e 17 OLiv F/ Inspector: Date: 4 1 — E $58.0 EINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: !Date: Pr ect: ,5Pt� •■► A c� (c) 1 t Type I nspection: t 6 'i .) A ess: AgoCo _..5 WA Date alled: (� Special Instructions: Date Wanted a — Lr(• —�( m. Requester: Phone No vU al q 46 I /} INSPECTION RECORD "_1..- Retain a copy with permit P'+ INSPECTION NO. PERMIT NO. }2 CITY OF TUKWILA BUILDING DIVISION IX 6300 S outhcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 (kp_ (...Approved per applicable codes. COMMENTS: scN G Ivet Mlr- `7C 5 N,(+.u#-[ 1 ReceI t No.: 'Date: AAA"-/ ( ��....��. . El Corrections required prior to approval. Li_ c__ d 0 REINSPECTIO THEE REQUI D. Prior to inspection, fee must be at 6300 Southcentef Blvd.. Suit 100. Call the schedule reinspection. Date: DEPARTMENTS: Public Works Complete Comments: PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG07 - 349 DATE: 02 - - PROJECT NAME: BANANA REPUBLIC SITE ADDRESS: 806 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 r Permit Issued n Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ ❑ Planning Division Permit Coordinator n DUE DATE: 02-26-08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 ❑ No further Review Required DATE: C DUE DATE: 03-5-08 Not Approved (attach comments) DATE: I I Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: PG07 -349 DATE: 12 -27 -07 PROJECT NAME: BANANA REPUBLIC SITE ADDRESS: 806 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued .,„ DEPARTMENTS: ing Ision iELJ Public IT ' I Work � y. D 1 Z�� DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete El Incomplete ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 `'PERMIT COORD COPY � PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Structural Review Required DATE: DATE: Planning Division Permit Coordinator No further Review Required C n DUE DATE: 01 -03-08 Not Applicable n n DUE DATE: 01-31-08 Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 211 I a9, cram Alolob Summary of Revision: Summary of Revision: U) y Annki C-,A-i Aft c, 1V1121J� -,0 l t. tv 3 M}h ki ' Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 211 I a9, cram Alolob Summary of Revision: Summary of Revision: U) y Annki C-,A-i Aft c, 1V1121J� -,0 l t. tv 3 M}h ki ' Received by: , ® jAMJ.A2 Pc-, oFn Cr ,oCn -n=7•o AV0 t btO ()1 U • Received by: Ka y S. 04.4i Lt REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: PROJECT NAME: SITE ADDRESS: a REVISION LOG PERMIT NO: f -�� ORIGINAL ISSUE DATE: I, ease print ease print ease print ease prin ease City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: frantitARY 11 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Cti, Revision # .i after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Lti°44 12 ` e f93 Qxu fhc crier Will Project Address:e b Soutficenter LAla11 Tit kwi Ia,WA qo:bit?) Contact Person: k a a7 .�G pppd,►lp,1 e € Phone Number: .-mo . f q (oo Summary of Revision: Sit. S ARV% orieinq I (4) 'io1n 5:ateC areas - -turned into (.3) main tale¢ atra S- gToCt RcoM : manage-1's gfict mo' od4ifion of go- back closet - Sheet Number(s): Ektel Ii' ra , "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: (,; Entered in Permits Plus on 1 0' \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Plan Check/Permit Number: Steven M Mullet, Mayor Steve Lancaster, Director Jail+ W I a - `I ES 1 PF' � �: F2t:ijlj License Information License OKITSCI959L8 Licensee Name OKITSU CONSTRUCTION INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602515973 Ind. Ins. Account Id PRESIDENT Business Type CORPORATION Address 1 1428 WHITWORTH AVE S Address 2 City RENTON County KING State WA Zip 98055 Phone 2067149969 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 6/28/2005 Expiration Date 6/28/2009 Suspend Date Separation Date Parent Company Previous License OKITSC*030R3 Next License Associated License Business Owner Information Name Role Effective Date Expiration Date OKITSU, RODNEY STERLING AGENT 06/28/2005 OKITSU, RODNEY STERLING PRESIDENT 06/28/2005 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= OKITSCI959L8 04/02/2008 NEW STORE BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 STORE NO.: 8997 STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Southcenter Parkway Tukwila, WA 98188 -2888 GAP PROJ. I.D.: 0000042134 PROTOTYPE DATE: 06/1 5/07 OPENING 2008 DESIGN CHANGES REV. #1 02.06.08 CONSULTANT INFO: MIME IIIIIMI k Consulting Engineers Energy Engineering Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744 -4400 EEA Project # 20795.3 ■ PROFESSI i s r _ WA.s�,� �- �Y 0, 1 3� 1 6 1VAld ?f /l IExP1REs o /o, / zota Firm Registration No. 2002 ARCHITECT INFO: McCall Design Group 550 Kearny Street Suite 710 San Francisca CA 94108 t . 4 1 5 . 2 8 8 . 8 1 5 0 1. 4 1 5. 2 8 8. 8 1 8 1 www.mccalideslgn.com ISSUE TYPE: PERMIT /BID 12/21/07 ISSUE SCALE: 1/8 " =1' -0" DRAWN BY: HWR/WKK JOB NO.: 207338 SHEET TITLE: 7 .8 /IUCr SHEET NUMBER: M1 MECHANICAL PLAN 1/8" • T -O" 22x26 Wu•1111V4:IJ ` - -� ILr+R 14- SD -4 20 12"0 SD -3 319 FPB-'3 7 - EF 2 E )22x22 EXI HALLWAY 40-0 STOC KHOOM (306) (E)14" TE WOMFN'S TOILET 800,1 TG- 8 M EN'S TOILET ROOM FITTING ROOM vGR'S AREA OFFICE . 7-- RETURN AR OFE"NlNG i` (BY LANDLORD) 1 q- SD -4 SD-4 � SD - 4 SD -4 20 20 II 20 20 SD -4 20 O ][ SD -2 484 RD--1 656 SALES AREA 2 SALES AREA 3 -1 I 00 1 < 2 RD -1 514 SD -2 359 elg to SD -2 375 FP L r SALES AREA 1 0 ALE . QPY s Permit No. Filar review approval is subject to errors and omissions. Approval of construction documents does not au rite the violation of any adopted code or ordinance. Receipt of approved Field Co y and conditions is acknowledged: By Date. Lpr• _ City of Tukwila BUILDING OIVIS O 1 vivrk without prior NME: Revisions Tukwila Building $1/ill require a n and may include addition plan review tees. EN RY !SPLAY REA I ISPLAY REA 2 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 7 2008 Of Tukwila BUILDING DIVISION j SEPARATE PERMIT REQUIRED FOR: Mehanical ! Electrical ® Plumbing ® Gas Piping City of Tukwila BUILDING DIVISION HVAC CODED NOTES (100) PLACE "AS- BUILT" MECHANICAL DRAWINGS IN DRAWING TUBE. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. (304) DUCT MOUNTED SMOKE DETECTOR. WIRE THE THERMOSTAT FAN WIRE THROUGH THE NORMALLY CLOSED CONTACT ON THE SMOKE DETECTOR TO SHUT DOWN THE HVAC UNIT UPON SENSING SMOKE. SMOKE DETECTOR MUST BE INSTALLED IN AN ACCESSIBLE LOCATION. INSTALL REMOTE TEST /RESET STATION AS REQUIRED. COORDINATE LOCATION OF TEST STATION WITH G.C.. 305 FIRE DAMPER WITH ACCESS DOOR IN DUCT PENETRATING FIRE -RATED PARTITION. LABEL ACCESS DOOR WITH 2" HIGH STENCILED LETTERS IN BLACK ENAMEL PAINT DESIGNATING "FIRE DAMPER ACCESS ". LOCATE ACCESS DOOR ON ACCESSIBLE SIDE OF PARTITION. (306) FAN POWERED VARIABLE- AIR - VOLUME PARALLEL BOX. SUSPEND FROM STRUCTURE WITH IN -LINE COMBINATION RUBBER AND SPRING VIBRATION ISOLATORS. (309) AIR DEVICE TO BE USED AS ACCESS TO EQUIPMENT ABOVE CEILING. VERIFY THAT SWING OF DEVICE WILL NOT INTERFERE WITH OTHER CEILING ELEMENTS. ROUTE TOILET EXHAUST DUCT TO EXISTING LANDLORD SUPPLIED TOILET EXHAUST HEADER. FIELD VERIFY LOCATION AND SIZE OF EXISTING HEADER. NOTIFY G.C. IF HEADER SIZE WILL NOT SUPPORT DUCT CONNECTION. ( CONNECT NEW SUPPLY DUCTWORK TO EXISTING LANDLORD PROVIDED SUPPLY DUCT TAP. FIELD VERIFY SIZE AND LOCATION OF EXISTING TIE -IN POINT PRIOR TO BID. (401) 36 "x18" TRANSFER AIR OPENING. LOCATE OPENING HIGH AS POSSIBLE. COORDINATE EXACT LOCATION WITH OTHER DISCIPLINES. PROVIDE GRILLE (TG -1) ON EXPOSED SIDE OF OPENING. HVAC GENERAL NOTES 1. TENANT'S CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL WITHIN THE LANDLORD'S TENANT CRITERIA MANUAL INCLUDING ITS RULES AND REGULATIONS. 2. DO NOT ATTACH ANYTHING DIRECTLY TO SLAB OR ROOF DECK ABOVE. 3 4 3. TENANT SHALL MAINTAIN A MINIMUM OF 6" UNOBSTRUCTED CLEARANCE HEIGHT IN RETURN AIR PLENUM ABOVE CEILING ALLOWING FOR AIR FLOW BACK TO LANDLORD AIR CONDITIONING UNIT. REVIS1O\NO .! GENERAL NOTES 1. ALL ROUND AND FLAT OVAL SUPPLY, RETURN AND EXHAUST DUCTWORK SHALLBE LINDAB, UNITED MCGILL OR SEMCO DUCT SYSTEMS CONSISTING OF FITTINGS THAT ARE FACTORY I- IIIED WITH A SEAUNG GASKET AND SPIRAL DUCT WHICH, WHEN INSTALLED ACCORDING TO MANUFACTURER'S INSTRUCTIONS, WILL SEAL THE DUCT JOINTS WITHOUT THE USE OF DUCT SEALER. MATERIALS: ALL DUCT AND FITTINGS SHALL BE G -90 OR G -60 GALVANIZED. 2. SUBMITTALS: SUBMIT MANUFACTURER'S DUCT SYSTEM CATALOG DATA FOR REVIEW AND APPROVAL. SUBMIT SHALL INCLUDE DUCT, FITTING AND SELF SEAUNG GASKET CATALOG INFORMATION. SURVEY INFORMATION SPACE IS LOCATED ON LEVEL- 1,OF - FINISHED FLOOR TO BOTTOM OF DECK ABOVE IS APPROX 17' -5" FINISHED FLOOR TO BOTTOM OF LOWEST STRUCTURAL MEMBER (STEEL OR CONCRETE BEAMS) IS APPROX 17' -5" FINISHED FLOOR TO BOTTOM OF JOIST IS APPROX 17' -5" ALL OTHER EQUIPMENT, PIPING, AND DUCTWORK ELEVATIONS ARE AS NOTED ON THE DRAWINGS. NOTE: CONTRACTOR IS TO VERIFY ALL CONDITIONS IN THE FIELD PRIOR TO BIDDING WORK. ANY CONDITIONS THAT AFFECT THE INSTALLATION OF THIS PROJECT MUST IMMEDIATELY BE BROUGHT TO THE ATTENTION OF G.C.'S CONSTRUCTION MANAGER OR BE INCORPORATED IN THE BID. DUCTWORK SHALL NOT BE FABRICATED OR ANY EQUIPMENT ORDERED PRIOR TO APPROVAL BY G.C.'S CONSTRUCTION MANAGER. RECEIVED CITY OF TUKWILA FEB 19 2008 PERMIT C Air System Sizing Summary for BLOCK LOAD Air System Information Air System Name blockload Number of zones 1 Equipment Class UNDEF Floor Area 3766.0 ft Air System Type VAV Location Seattle IAP, Washington Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Calculation Months Jan to Dec Space CFM Coincident space loads Sizing Data Calculated Central Cooling Coil Sizing Data Total coil load 6.9 Tons Load occurs at Jul 1600 Total coil load 83.2 MBH OA DB / WB 84.5 / 64.8 °F Sensible coil load 78.2 MBH Entering DB / WB 72.0 / 62.3 °F Coil CFM at Jul 1600 5125 CFM Leaving DB / WB 57.6 / 56.7 °F Max block CFM at Jan 1900 5307 CFM Coil ADP 56.1 °F Sum of peak zone CFM 5307 CFM Bypass Factor 0.100 Sensible heat ratio 0.940 Resulting RH 64 % ff/Ton 543.3 Design supply temp. 58M °F BTU /(hr -ff) 22.1 Zone T -stat Check 1 of 1 OK Water @ 10.0 °F rise 16.65 gpm Max zone temperature deviation 0.0 °F Supply Fan Sizing Data Actual max CFM at Jan 1900 5307 CFM Fan motor BHP 0.77 BHP Standard CFM 5221 CFM Fan motor kW 0.58 kW Actual max CFMVft 1.41 CFMIft Fan static 0.50 inwg Outdoor Ventilation Air Data Design airflary CFM 708 CFM CFM/person 15.48 CFM/person CFM/ft 0.19 CFM/ft Zone Sizing Summary for BLOCK LOAD Air Sizing Zone Zone Space System Information Air System Name blockload Number of zones 1 Equipment Class UNDEF Floor Area 3766.0 ft Air System Type VAV Location Seattle IAP, Washington Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Calculation Months Jan to Dec Space CFM Coincident space loads Sizing Data Calculated Sizing Data Total coil load 6.9 Tons Load occurs at Jul 1600 Zone Name Maximum Cooling Sensible (MBH) Design Air Flow (CFM) Minimum Air Flow (CFM) lime of Peak Load Maximum Heating Load (MBH) Zone Floor Area (ft Zone CFM/ft Zone 1 67.7 5307 708 Jan 1900 0.0 3766.0 1.41 Terminal Sizing Data Air System Name VAV Number of zones 3 Zone Name Reheat Coil Load (MBH) Reheat Coil Water gpm @ 20.0 °F Zone Htg Coil Load (MBH) Zone Htg Water gpm @ 20.0 °F Mixing Box Fan Airflow (CFM) Zone 1 7.5 0.75 0.0 0.00 1 Loads and Airflows Zone Name / Space Name Mult Cooling Sensible (MBH) Time of Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft Space CFM/ft Cooling Zone I Air of Heating Floor FPB -3 CARRIER 45J 3 Fitting Rooms 1 4.3 Jan 1900 340 0.0 506.0 0.67 1/4 Manager's Office 1 7.0 Jan 1900 550 0.0 92.0 5.98 Restrooms 1 1.3 Jan 1900 99 0.0 301.0 0.33 1.39 Sales 1 1 15.1 Jan 1900 1185 0.0 890.0 1.33 2294.0 Sales 2 1 9.4 Jan 1900 734 0.0 490.0 1.50 0.0 Sales 3 1 9.3 Jan 1900 732 0.0 484.0 1.51 Sales 4 1 8.6 Jan 1900 673 0.0 497.0 1.35 Reheat Stockroom 1 12.7 Jan 1900 994 0.0 506.0 1.96 Water Coil Air System Design Load Summary for BLOCK LOAD Box Fan DESIGN COOLING DESIGN HEATING Load COOLING DATA AT Jul 1600 COOLING OA DB/ WB 84.5 °F/ 64.8 °F HEATING DATA AT DES HTG HEATING OA DB/ WB 23.0 °F /19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU /hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 0 ff 0 - 0 ft= - - Wall Transmission 0 fe 0 - 0 ff 0 - Roof Transmission 0 ff 0 - 0 ff 0 - Windcw Transmission 0 ff 0 - 0 ff 0 - Skylight Transmission 0 ff? 0 - 0 fi? 0 - Door Loads 0 ff'- 0 - 0 if 0 - Floor Transmission 3766 ff 0 - 3766 ff 0 - Partitions 0 ff 0 - 0 ff? 0 - Ceiling 0 ff 0 - 0 ff 0 - Overhead Lighting 0 W 0 - 0 0 - Task Lighting 9648 W 28875 - 0 0 - Electric Equipment 2258 W 7705 - 0 0 - People 46 8582 9151 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 7700 0 - 0 0 Safety Factor 25% / 0% 13216 0 0% 0 0 >> Total Zone Loads - 66078 9151 - 0 0 Zone Conditioning - 65870 9151 - -5 0 Flenum Wall Load 0% 0 - 0 0 - Renum Roof Load 0% 0 - 0 0 - Fienum Lighting Load 0% 0 - 0 0 - Return Fan Load 5125 CFM 0 - 708 CFM 0 - Ventilation Load 684 CFM 10433 -4174 95 CFM 4510 0 Supply Fan Load 5125 CFM 1906 - 708 CFM -571 - Space Fan Coil Fans - 0 - 0 - Duct Heat Gain / Loss 0% 0 0% 0 - » Total System Loads - 78209 4977 - 3934 0 Central Cooling Coil - 78209 4979 - -3512 0 Terminal Reheat Coils - 0 - - 7446 - » Total Conditioning - 78209 4979 - 3934 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are cig loads Air System Sizing Summary for FPB -1 Air System Information Air System Name VAV Number of zones 3 Equipment Class UNDEF Floor Area 3766.0 ff Air System Type VAV Location Seattle IAP, Washington Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Calculation Months Jan to Dec Space CFM Coincident space loads Sizing Data Calculated Central Cooling Coil Sizing Data Total coil load 6.9 Tons Load occurs at Jul 1600 Total coil load 83.2 MB H OA DB / WB 84.5 / 64.8 °F Sensible coil load 78.2 MBH Entering DB / WB 72.0 / 62.3 °F Coil CFM at Jul 1600 5124 CFM Leaving DB / WB 57.6156.7 °F Max block CFM at Jan 1900 5307 CFM Coil ADP 56.1 °F Sum of peak zone CFM 5307 CFM Bypass Factor 0.100 Sensible heat ratio 0.940 Resulting RH 64 % ff/Ton 543.4 Design supply temp. 58.0 °F BTU/(hr -ft 22.1 Zone T -stat Check 3 of 3 OK Water flow @ 10.0 °F rise 16.64 gpm Max zone temperature deviation 0.0 °F Supply Fan Sizing Data Actual max CFM at Jan 1900 5307 CFM Fan motor BHP 0.77 BHP Standard CFM 5221 CFM Fan motor kW 0.58 kW Actual max CFM/ft 1.41 CFMift Fan static 0.50 inwg Outdoor Ventilation Air Data Design airflow CFM 708 CFM CFMVperson 15.48 CFM'person CFM/ft 0.19 CFM'ft Air System Information Air System Name VAV Number of zones 3 Equipment Class UNDEF Floor Area 3766.0 ft Air System Type VAV Location Seattle MAP, Washington Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Calculation Months Jan to Dec Space CFM Coincident space loads Sizing Data Calculated Zone Sizing Data 135 FPB -3 14 Maximum Design Minimum Time Maximum Zone 500 2369 8 480/3/60 Cooling Air Air of Heating Floor FPB -3 CARRIER 45J 3 Sensible Flow Flow Peak Load Area Zone 0.65 1/4 Zone Name (MBH) (CFM) (CFM) Load (MBH) (ft CFM /ft Zone 1 24.5 1919 276 Jan 1900 0.0 1380.0 1.39 Zone 2 36.2 2838 419 Jan 1900 0.0 2294.0 1.24 Zone 3 7.0 550 14 Jan 1900 0.0 92.0 5.98 Zone Terminal Sizing Data Reheat Zone Zone Reheat Coil Htg Htg Mixing Coil Water Coil Water Box Fan Load gpm Load gpm Airflow Zone Name (MBH) @ 20.0 °F (MBH) @ 20.0 °F (CFM) Zone 1 2.9 0.29 0.0 0.00 1 Zone 2 4.5 0.45 0.0 0.00 1 Zone 3 0.1 0.01 0.0 0.00 1 Space Loads and Airflows Cooling Time Air Heating Floor Zone Name / Sensible of Flow Load Area Space Space Name Mult. (MBH) Load (CFM) (MBH) (ft CFM /ft Zone 1 Sales 1 1 15.1 Jan 1900 1185 0.0 890.0 1.33 Sales 2 1 9.4 Jan 1900 734 0.0 490.0 1.50 Zone 2 Fitting Rooms 1 4.3 Jan 1900 340 0.0 506.0 0.67 Restrooms 1 1.3 Jan 1900 99 0.0 301.0 0.33 Sales 3 1 9.3 Jan 1900 732 0.0 484.0 1.51 Sales 4 1 8.6 Jan 1900 673 0.0 497.0 1.35 Stockroom 1 12.7 Jan 1900 994 0.0 506.0 1.96 Zone 3 Manager's Office 1 7.0 Jan 1900 550 0.0 92.0 5.98 Design Weather Parameters City Name Seattle IAP Location Washington Latitude 47.5 Deg. Longitude 122.3 Deg. Elevation 449.0 ft Summer Design Dry-Bulb 85.0 °F Summer Coincident Wet -Bulb 65.0 °F Summer Daily Range 18.3 °F Winter Design Dry -Bulb 23.0 ° F Winter Design Wet -Bulb 19.2 °F Atmospheric Clearness Number 1.05 Average Ground Reflectance 0.20 Soil Conductivity 0.800 BTU /(hr- ft - °F) Local Time Zone (GMT +/- N hours) 8.0 hours Consider Daylight Savings Time No Simulation Weather Data none N/A Current Data is 2001 ASHRAE Handbook Design Cooling Months January to December OUTSIDE AIR REQUIREMENTS MODEL UNIT SIZE ROOM PURPOSE GROSS FLOOR AREA (SQ. FT.) ASHRAE 62 -89 OUTSIDE AIR REQUIREMENTS MIN. FAN AIR (CFM) SYSTEM NUMBER ACTUAL OUTSIDE AIR (CFM) REMARKS INPUT kW (CFM /SF) (CFM) SALES 2,361 0.20 472 FPB -1 276 OA BY LL SUPPLY AIR FITTING RMS 506 0.20 101 FPB -2 419 OA BY LL SUPPLY AIR NON -SALES 899 0.15 135 FPB -3 14 OA BY LL SUPPLY AIR TOTAL 708 TOTAL 709 6 FAN POWERED VAV BOX SCHEDULE MARK MAN U F. MODEL UNIT SIZE INLET SIZE PRIMARY AIR (CFM) MIN. PRIMARY AIR (CFM) MIN. FAN AIR (CFM) HEATER FAN REMARKS INPUT kW V /PH /HZ STAGES S.P. (IN. W.G.) HP FLA V /PH /HZ FPB -1 CARRIER 45J 6 12 1919 276 1919 5.5 480/3/60 2 0.55 3/4 4.4 277/1/60 1,2,3,4 FPB -2 CARRIER 45J 6 14 2369 500 2369 8 480/3/60 2 0.75 2 -3/4 9.9 277/1/60 1,2,3,4 FPB -3 CARRIER 45J 3 r 8 550 14 550 1 277/1/60 1 0.65 1/4 1.5 277/1/60 1,2,3,4 REMARKS: 1. MANUFACTURED BY CARRIER. 2. PROVIDE 45JA -2212 CONTROL PACKAGE COMPLETE WITH THERMOSTAT AND TRANSFORMER. 3. PROVIDE INTEGRAL DISCONNECT SWITCH. 4. CONTRACTOR SHALL FURNISH AND INSTALL THREE (3) SETS OF STANDARD 1" AIR FILTERS. CONTRACTOR TO REPLACE FILTERS JUST PRIOR TO AIR BALANCING AND ONCE AGAIN AFTER FINAL STORE CLEANING IS COMPLETE. NEW STORE BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 STORE NO.: 8997 STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Southcenter Parkway Tukwila, WA 98188 -2888 GAP PROJ. I.D.: 0000042134 PROTOTYPE DATE: 06/15/07 OPENING 2008 DESIGN CHANGES REV. #1 02.06.08 Q CONSULTANT INFO: MEM MI= Consulting Engineers Energy Engineering Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744 -4400 EEA Project # 2079563 PROFESSIONAL ST • MP ONALO - /L L�ErXPIRES oyz/oazd10 Firm Registration No. 2002 ARCHITECT INFO: McCall Design Group 550 Keamy Street Suite 71 0 San Frpnci5co CA 94108 (.415.288.8150 f. 4 1 5. 2 8 8. 8 1 8 1 www.mccalldeslgn.com ISSUE TYPE: PERMIT /BID 12/21/07 ISSUE SCALE: NOT TO SCALE DRAWN BY: MM JOB NO.: 207338 SHEET TITLE: MECHANICAL SCHEDULES SHEET NUMBER: M2-O 11 1 HVAC Equipment Schedule Manufacturer: Carrier RECEIVED CITY OF TUKWILA FEB 19 2008 PERMIT CENTER PLUMBING SCHEDULE MARK DESCRIPTION FIXTURE VALVE/FAUCET CONNECTIONS VOLTAGE PHASE WATTS REMARKS MFR MODEL MFR MODEL WASTE VENT CW HW WC-1 WATER CLOSET HANDICAP AMERICAN STANDARD CADET #2377.100, WHITE - - 4" 2" 3/4" - - - - 1, 7 LAV LAVATORY KOHLER K -2035 AMERICAN STANDARD MONTEREY #6530.170 1 -1/2" 1 -1/2" 1/2" 1/2" - - - 2 EWH WATER HEATER TANK BRADFORD WHITE M- 1 -6U6SS 6- GALLON - - - - 3/4" 3/4" 120 1 1500 - EWC ELECTRIC WATER COOLER ELKAY EZTLBC TWO LEVEL - - 1 -1/2" 1 -1/2" 1/2" - 120 1 325 4 MS MOP SINK FIAT PRODUCTS #MSB -2424 AMERICAN STANDARD UTILITY #8344.112.004 3" 1 -1/2" 3/4" 3/4" - - - 5 FD FLOOR DRAIN J.R. SMITH 2005A -P050 - - 3" 1 -1/2" - - - - - 6 TP TRAP PRIMER PRECISION PLUMBING PRIME -RITE - - - - 1/2" -- - - - - WCO WALL CLEAN OUT - - - - - - - - - 3 WHA WATER HAMMER ARRESTERS ZURN SHOCKTROL - - - - - - - - - - ET EXPANSION TANK WATTS PET-5 2- GALLON - - - - 3/4" - -- - - - AP WALL ACCESS PANEL ZURN FAUCET ZANB- 1460 -11 11" x 11" - - - - - - - - - REMARKS: 1 PROVIDE WITH BEMIS MANUFACTURING WHITE OPEN FRONT SEAT LESS COVER #1955SSC. 2 PROVIDE WITH PLUMBEREX MODEL PROEXTREME MODEL #X4111 AND X4112 FOR TRAP AND SUPPLY PROTECTION. 3 CAST IRON CLEANOUT TEE WITH BRONZE THREADED CLEANOUT PLUG. PLUG TO BE GAS AND WATER TIGHT. 4 PROVIDE WITH DEARBORN 17GA. TRAP, TRAP ADAPTER AND ANGLE STOP. 5 PROVIDE WITH FIAT PRODUCTS VINYL BUMPERGAURD #E- 77 -AA. 6 FLOOR DRAIN TO BE PROVIDED WITH TRAP PRIMER CONNECTION. 7 PRESSURE ASSISTED TANK -TYPE. RESPONSIBILITY MATRIX LEGEND QTY STOREFRONT EXTRUSION L 0 FACTORY FINISHED WC -1 2 2.5 5 4 L = LANDLORD 0 = OWNER (GAP INC. FURNISHED BY 2 1 COMMENTS 1 2 ITEM 1 3 3 GC= GENERAL CONTRA TOR 3 EWC 2 .5 1 INSTALLED BY 1 TOTALS RESPONSIBILITY MATRIX WATER LINE TO LEASE SPACE L L SEWER LINE TO LEASE SPACE L L REMARKS: NOTE: TIE RESPONSIBILITY MATRIX ONLY DELINEATES ITEMS SUPPLIED AND /OR INSTALLED BY OWNER AND / 0T LANDLORD. ANY WORK BY CONSTRUCTION DOCUMENTS NOT DEFINED AS RESPONSIBILITY OF OWNER OfR LANDLORD IS SUPPLIED AND INSTALLED BY GENERAL CONTRACTOR. SEE BID CLARIFICATION LETTER .FOR ANY VARIATION BY SCOPE OF WORK RESPONSIBILITY. FIXTURE QTY SUPPLY UNITS SUPPLY TOTAL FU WASTE UNITS WASTE TOTAL FU WC -1 2 2.5 5 4 8 LAV 2 1 2 1 2 MS 1 3 3 3 3 EWC 2 .5 1 .5 1 TOTALS 11 14 ENLARGED PLUMBING PLAN - RESTROOMS REFER TO RISER DIAGRAMS ON SHEET M3-1 FOR ADDITIONAL PIPE SIZES NOT SHOWN 1 /4" = 1' -0" 101 z FIT11NG ROOM MGR'S AR A OFFICE DisplAy AREA 1 DISPLAY. ARLA 2 OVERALL PLUMBING PLAN • • PROVIDE AND INSTALL A REDUCED PRESSURE BACKFLOW PREVENTER WITHIN THE SPACE PRIOR TO MAKING ANY OTHER CONNECTIONS TO THE WATER SERVICE PIPING. GENERAL NOTES 1. TENANT'S CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL WITHIN THE LANDLORD'S TENANT CRITERIA MANUAL INCLUDING ITS RULES AND REGULATIONS. 2. TENANT'S CONTRACTOR IS TO VERIFY LOCATION; GET APPROVAL AND REQUIREMENTS FOR ALL TRENCHING WITH WESTFIELD'S ON —SITE TENANT COORDINATORS BEFORE PROCEEDING WITH WORK. 3. TENANT'S CONTRACTOR SHALL PROVIDE A FIRE WATCH AND PORTABLE FIRE EXTINGUISHER WHERE EVER ANY WELDING IS DONE WITHIN THE DEMISED PREMISES. THE PERSON PERFORMING THE FIRE WATCH SHALL REMAIN IN THE TENANT SPACE FOR AT LEAST 1 HOUR AFTER THE COMPLETION OF ANY WELDING. THIS SHALL BE COORDINATED THROUGH THE CITY OF TUKWILA FIRE DEPARTMENT. 4. ALL TENANTS ON THE GROUND FLOOR REQUIRING BELOW GRADE WORK SHALL COORDINATE WITH LANDLORD PRIOR TO ANY SLAB DEMOLITION. COORDINATE WITH LANDLORD TO PROVIDE OPPORTUNITY FOR SPECIAL INSPECTION AND PHOTOGRAPHIC DOCUMENTATION BY LANDLORD OF BELOW GRADE WORK PRIOR TO THE COVERING UP OF SUCH WORK. CONTRACTOR SHALL BE RESPONSIBLE FOR RECONSTRUCTION AND PATCHING OF THE SLAB —ON —GRADE SYSTEM, INCLUDING GRAVEL LAYERS, VAPOR BARRIER, AND CONCRETE. R C OD E 1/16" = 1' - 0" 100 PLUMBING CODED NOTES CONNECT NEW SANITARY LINE INTO THE LANDLORD'S EXISTING SANITARY SERVICE AS SHOWN. FIELD VERIFY EXACT LOCATION AND DIRECTION OF FLOW OF LANDLORD'S MAIN PRIOR TO BIDDING. INSTALL CLEANOUT AT CONNECTION TO LANDLORD'S MAIN AND COORDINATE LOCATION AND TYPE OF COVER REQUIRED TO MATCH FLOOR FINISH WITH C.C. REFER TO WASTE AND VENT RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. EXTEND NEW VENT TO EXISTING LANDLORD SUPPLIED TIE —IN POINT. REFER TO WASTE AND VENT RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. CONNECT NEW COLD WATER LINE INTO THE EXISTING COLD WATER TAP. NOTIFY G.C. IF TAP IS SMALLER THAN SHOWN. REFER TO COLD WATER AND HOT WATER RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. FIELD VERIFY EXACT LOCATION OF EXISTING TAP PRIOR TO BID. INSTALL 1/2" WATER PIPE FROM TRAP PRIMER DOWN IN WALL UNDER FLOOR TO FLOOR DRAIN. TRAP PRIMER TO BE LOCATED IN AN ACCESSIBLE LOCATION WITH ACCESS PANEL. INSTALL DRAWING TUBE HOLDER FOR STORAGE OF ALL CONTRACTORS "AS— BUILT" DRAWINGS. PLACE "AS— BUILT" PLUMBING DRAWINGS IN TUBE. A PLUMBING GENERAL NOTES 1. THE ABBREVIATION G.C., WHEREVER IT APPEARS IN THESE PLUMBING DRAWINGS, SHALL REFER TO THE GENERAL CONTRACTOR. 2. THE CONTRACTOR FOR THIS DMSION OF WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUB — CONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 3. ALL ROOF CUTTING, PATCHING AND FLASHING REQUIRED TO INSTALL THE PLUMBING SYSTEMS SHALL BE BY A LANDLORD APPROVED ROOFING CONTRACTOR. COORDINATE ROOF PENETRATIONS WITH LANDLORD AND G.C. 4. ALL PLUMBING FIXTURES SHALL BE INSTALLED WITH STOP VALVES TO ISOLATE EACH FIXTURE. REFER TO RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 5. ALL SHUT —OFF VALVES LOCATED IN AREAS WITH HARD CEILINGS SHALL HAVE ACCESS PANELS INSTALLED. COORDINATE LOCATION AND TYPE WITH G.C. AND ARCHITECT. 6. CONTRACTOR TO VERIFY THAT ALL ITEMS ON CONTRACTOR CHECKLIST ARE COMPLETED PRIOR TO MEP COMMISSIONING. CONTRACTOR WILL RECEIVE CONTRACTOR CHECKLIST IN ELECTRONIC FORM WITH BID DOCUMENTS. E COMPLIANCE r PLUMBING SYMBOLS LEGEND F G D —o ID 0 iJ lit ua AFF /AFG VTR CO BFP FCO WCO WHA TP COLD WATER (CW) FIRE PROTECTION (F) (SPRINKLER /STANDPIPE) HOT WATER (HW) GAS LINE (G) CONDENSATE LINE (D) PLUMBING VENT (V) SANITARY WASTE (SAN) BELOW SLAB /GRADE PIPE TURNING UP /DOWN TEE TURNING UP /DOWN SHUTOFF VALVE (BALL TYPE) CHECK VALVE REDUCER ABOVE FINISHED FLOOR /GRADE VENT THRU ROOF CLEAN OUT BACKFLOW PREVENTER CONNECT TO EXISTING FLOOR CLEAN OUT FLOOR DRAIN WALL CLEAN OUT WATER HAMMER ARRESTOR TRAP PRIMER Poi- 3H1 RECEIVED CITY OF TU FEB 19 2008 PERMIT CENTER BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 STORE NO.: 8997 STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Southcenter Parkway Tukwila, WA 98188 -2888 GAP PROJ. I.D.: 0000042134 PROTOTYPE DATE: 06/15/07 OPENING 2008 DESIGN CHANGES REV. #1 02.06.08 CONSULTANT INFO: PROFESSI o NAL Consulting Engineers Energy Engineering Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744 -4400 EEA Project # 207956 ELF' ES 10 Firm Registration No. 2002 ARCHITECT INFO: McCall Design Group 550 Kearny Street Suite 710 San Francisco CA 94108 }. 4 1 5. 2 8 8. 8 1 5 0 }.415.288.8181 www.mccalldesign.com ISSUE TYPE: PERMIT /BID 12/21 /07 ISSUE SCALE: AS NOTED DRAWN BY: DKZ/WKK JOB NO.: 207338 SHEET TITLE: PLUMBING PLAN AND SCHEDULES NEW STORE SHEET NUMBER: M3 -0 DRAWING TUBE NOT TO SCALE 102 GATE /BALL VALVE(TYP.) 3/4"- THERMAL 3/4� EXPANSION ,I TAN K SECURE TO WALL FOR SEISMIC BRACING WHERE REQUIRED BY CODE. DRAIN VALVE -' SHELF ABOVE MOP SINK CEILING TO BE MOUNTED ON THE WALL OR PLATFOR 1" RUN FULL SIZE TO MOP SINK 4 3 TANK WATER HEATER 4 " - INSULATE ALL PIPING IN ACCORDANCE WITH SPECIFICATIONS UNION (TYP.) 3/4" T & P RELIEF VALVE WATER HEATER SEE PLUMBING FIXTURE SCHEDULE FOR ADDITIONAL INFO. 2" WIDE, 20 GA. SHEET METAL BAND, SECURE TO WALL FOR SEISMIC BRACING WHERE REQUIRED BY CODE. GALV. DRIP PAN. PROVIDE 6" CLEARANCE BETWEEN WATER HEATER AND GALV. DRIP PAN ON ALL SIDES SEPARATE 1" DRAINS TO MOP SINK NOT TO SCALE 300 COLD WATER ND HOT WATER RISER DIAGRAM WASTE AND VENT RISER DIAGRAM NOT TO SCALE 101 NOT TO SCALE 100 RECEIVED CITY OF TEL <'iVILA FEB 19 2008 PERMIT CENTER DESIGN CHANGES REV. #1 02.06.08 CONSULTANT INFO: Consulting Engineers Energy Engineering Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744 -4400 EEA Project # 20 9563 PROFESSI NA S Firm Registration No. 2002 ARCHITECT INFO: McCall Design Group 550 Kearny Street Suite 710 San Francisco CA 94108 t. 4 1 5- 2 8 8. 8 1 5 0 f. 415.288.8181 www.mccalldesign.com ISSUE TYPE: PERMIT /BID 12/21 /07 ISSUE SCALE: AS NOTED DRAWN BY: DKZNVKK JOB NO.: 207338 SHEET TITLE: PLUMBING DETAILS AND RISERS SHEET NUMBER: M3 -1 1/4" DIAMETER THRU BOLT WITH TOGGLE (TYP. OF 2) PAN HEAD SCREWS TO SECURE STRAPS 3/4" X 2" POPULAR PLYWOOD TRIM SCREWED TO 2 "X4" METAL STRAP (TYP. OF 2) SECTION NTS LOOSE PVC TOP CAP ATTACH A LABEL (WITH CLEAR TAPE) STATING- THIS TUBE CONTAINS STORE DRAWINGS AND IS NOT TO BE REMOVED WITHOUT THE CONSENT OF THE STORE MANAGER. THANK YOU. EXTENT OF WOOD HOLDER PVC BOTTOM CAP GLUED IN PLACE LABEL n 26" 24" A.F.F. ELEVATION NTS NEW STORE BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 STORE NO.: 8997 STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Southcenter Parkway Tukwila, WA 98188 -2888 GAP PROJ. I.D.: 0000042134 PROTOTYPE DATE: 06/15/07 OPENING 2008 SPRINKLER MAIN TO LEASE SPACE L L REMARKS • BACK -FLOW PREVENTOR AND FLOW DETECTOR L L RECESSED HEAD L = LANDLORD 0 = OWNER (GAP INC.) FURNISHED BY REMARKS. P601 9 1 NOTE: THE RESPONSIBILITY MATRIX ONLY DELINEATES ITEMS SUPPLIED AND /OR INSTALLED BY OWNER AND / OR LANDLORD. ANY WORK BY CONSTRUCTION DOCUMENTS NOT DEFINED AS RESPONSIBILITY OF OWNER OR LANDLORD IS SUPPLIED AND INSTALLED BY GENERAL CONTRACTOR. SEE BID CLARIFICATION LETTER FOR ANY VARIATION BY SCOPE OF WORK RESPONSIBILITY. F SPRINKLER HEAD LEGEND SYMBOL DESCRIPTION REMARKS • CONCEALED HEAD ® RECESSED HEAD L = LANDLORD 0 = OWNER (GAP INC.) FURNISHED BY ITEM RESPONSIBILITY MATRIX LEGEND STOREFRONT EXTRUSION L 0 FACTORY FINISHED L = LANDLORD 0 = OWNER (GAP INC.) FURNISHED BY ITEM --- —COMMENTS GC= GENERAL CONTRACTOR INSTALLED BY N, E XIT I ! WAY IOCKPo OP.,1 711 'S OME N'S MEETS cD F. TOILE T ROOM TOILET ROOM • C'7 TT1NG ROOM MGR'S • • • • 7 ' _ 1 to 70-1777=-70— SALES AREA 3 • i d 200 • • v SALES AREA 1-1 • • t • DISPLAY AREA 1 EN1RY DISPLAY AREA 2 z FIRE SPRINKLER PLAN v8 -r -O' 100 200 SPRINKLER GENERAL NOTES 1. THE ABBREVIATION GC, WHEREEVER IT APPEARS IN THESE MECHANICAL AND ELECTRICAL DRAWINGS, SHALL REFER TO THE GENERAL CONTRACTOR. 2. THE CONTRACTOR FOR THIS DIVISION OF WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 3. FIRE PROTECTION PLANS, SPRINKLER DRAWINGS, MUST BE ENGINEERED AND WET SIGNED BY A LANDLORD APPROVED, LICENSED REGISTERED FIRE PROTECTION CONTRACTOR IN THE LOCAL JURISDICTION. FINAL INSTALLATION MUST COMPLY WITH NFPA 13 AND STATE AND LOCAL AUTHORITIES HAVING JURISDICTION. 4. SPRINKLER HEAD LAYOUT IS A SUGGESTED LAYOUT. COORDINATE SPRINKLER HEAD LAYOUT AND PIPE ROUTING WITH ARCHITECTURAL PLANS, STRUCTURAL PLANS, HVAC CONTRACTOR, ELECTRICAL CONTRACTOR AND THE G.C. THIS CONTRACTOR SHALL INCLUDE IN THE BID AND BE RESPONSIBLE FOR EXACT QUANTITY OF SPRINKLER HEADS REQUIRED FOR COVERAGE AND FINAL APPROVAL. 5. LOCATE SPRINKLER MAIN AND RELATED SHUT OFF VALVES IN AN ACCESSIBLE LOCATION WITHIN THE STOCKROOM. SPRINKLER CODED NOTES PLACE "AS- BUILT" SPRINKLER DRAWINGS IN DRAWING TUBE. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. ADJUST SPRINKLER HEADS REQUIRED BY NFPA13 TO AVOID DUCTWORK. COORDINATE INSTALLATIONS OF HEADS WITH HVAC CONTRACTOR AND G.C. �'' 2008 Of kkh96 RESPONSIBILITY MATRIX RECEIVED .ITY OF TUn1/ FEB 19 Z008 EHMIT CENTER NEW STORE BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 STORE NO.: 8997 LA STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Southcenter Parkway Tukwila, WA 98188 -2888 GAP P R OJ. I.D.: 0000042134 PROTOTYPE DATE: 06/15/07 OPENING 2008 DESIGN CHANGES REV. #1 02.06.08 CONSULTANT INFO: NMI Consulting Engineers Energy Engineering Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744 -4400 EEA Project # 2079563 Firm Registration No. 2002 ARCHITECT INFO: ISSUE TYPE: PERMIT /BID ISSUE SHEET NUMBER: M4 -0 McCall Design Group 550 Kearny Street Suite 710 San Francisco CA 94108 t - 4 1 5. 2 8 8. 8 1 5 0 f. 415.288.8181 www.mccalidesign.com 12/21/07 SCALE: 1/8 " =1' -0" DRAWN BY: DKZIWKK JOB NO.: 207338 SHEET TITLE: FIRE SPRINKLER PLAN