Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D08-077 - WESTFIELD SOUTHCENTER MALL - GODIVA - TENANT IMPROVEMENT
GODIVA 555 SOUTHCENTER MALL D08 -077 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us CERTIFICATE OF OCCUPANCY This certificate is issued pursuant to the requirements of Section 110.2 of the 2006 edition of the International Building Code. At the time of issuance, this structure or portion thereof has been inspected for compliance with the requirements of this code for the occupancy and division of occupancy and the use for which the proposed occupancy is classified. Building Permit No.: D08 -077 Occupant /Tenant: GODIVA CHOCOLATIER Building Address: 555 SOUTHCENTER MALL, SUITE NO. Parcel No.: 6364200010 Property Owner: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA 92013 Use: RETAIL Occupancy Group /Division: M Type of Construction: II -B Automatic Sprinkler System: Provided: Y Required: Y Design Occupant Load: BUILDING OFFICIAL 23 Cieez Z6Vg DATE THIS CERTIFICATE TO BE CONSPICUOUSLY POSTED ON THE PREMISES Parcel No.: 6364200010 Address: 555 SOUTHCENTER MALL TUKW Suite No: Tenant: Name: GODIVA CHOCOLATIER Address: 555 SOUTHCENTER MALL , TUKVVILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Phone: Contact Person: Name: DEB SUBOTNIK Address: 11006 NE 41ST DR , KIRKLAND WA 98033 Phone: 800 - 407 -7990 X 581 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Contractor: Name: MARKET CONTRACTORS (WA) LTD Address: 10250 NE MARX ST , PORTLAND, OR 97220 Phone: 503 - 255 -0977 Contractor License No: MARKECW066NU doc: IBC -10/06 Citylif Tukwila • DEVELOPMENT PERMIT Permit Number: D08 -077 Issue Date: 04/16/2008 Permit Expires On: 10/13/2008 Value of Construction: $150,000.00 Fees Collected: $2,694.00 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2006 Type of Construction: II-B Occupancy per IBC: 0019 Expiration Date: 09/13/2008 DESCRIPTION OF WORK: RELOCATE EXISTING KIOSK TO NEW RETAIL TENANT SPACE. WORK TO INCLUDE NEW FINISHES, MILL WORK, CABINETRY AND CASH WRAP. NO STRUCTURAL ELEMENTS TO BE ALTERED. * * continued on next page ** D08 -077 Printed: 04 -16 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N City 6 Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: doc: IBC -10/06 (A2 Permit Number: D08 - 077 Issue Date: 04/16/2008 Permit Expires On: 10/13/2008 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit. Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D08 -077 Printed: 04 -16 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 555 SOUTHCENTER MALL TUKW GODIVA CHOCOLATIER PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D08 -077 ISSUED 02/08/2008 04/16/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: Fire retardant treated wood shall have a flame spread of not greater than 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) doc: Cond -10/06 D08 -077 Printed: 04 -16 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 16: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 17: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 18: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 19: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 20: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 21: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 22: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 23: Gates serving the means of egress system shall comply with the requirements of the International Fire Code. Gates used as a component in a means of egress shall conform to the applicable requirements for doors. (IFC 1008.2) 24: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 25: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 26: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 27: All new sprinkler systems and all modifications to existing sprinlder systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinlder systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinlder work shall commence without approved drawings. (City Ordinance #2050) 28: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2051. doc: Cond -10/06 D08 -077 Printed: 04 -16 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 29: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 30: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 31: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 32: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 33: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 34: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 35: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** D08 -077 Printed: 04 -16 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: doc: Cond -10/06 Print Name: CJ 070 X c DK l Date: 1 7 1 -" -- 1‘ — C D08 -077 Printed: 04 -16 -2008 CITY OF TUKWILIP Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htlp: /hvwsv. ci. iukwilawa us Site Address: ■ )c 0.51,11-\C..a - Tenant Name: ei r)c , , l .ham' 1(- . Property Owners Name: L,. )Pts 01 C ry Q.c Mailing Address: lit i71 t 1411', n .0 �I c �n1 t 1L 1 cr..41 Name: -- . De . ) ,- ) , ) \0( 414 Mailing Address: 1 \ C ' (p (A P . a \ �-- Z Contact Person: E -Mail Address: Contractor Registration Number: Company Name: •p./1 AP.(J � 1 Mailing Address: l 0 l CAlnA Contact Person: E -Mail Address: (L 5( '1 hi' n OtiLe ? e . & L66 1.11 City .. • • (C•1 Q:\Applications \Forms- Appliations On Line\3 -2006 - Permit Appliationdoc Revised: 4.2006 bh • Building Permit No DO e- O7 7 _ Mechanical Permit No. 7)!0 Plumbing/Gas Permit No. % ng- 01,1 —I Public Works Permit No. Project No. ?o. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: l0 36 L W — On I 0 1 (:::Q(7 Floor: r New Tenant: Yes ❑ ..No Suite Number: City State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Day Telephone: `ac - '4Q q- 'Ft0 )8I tl L�`Y-A 6C City State Zip E -Mail Address: A -,(.4.)( v\l e' N ,.l c 1::5 3t r .�.\WI Fax Number: L - q Cti>- 4 115 I G ENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: It) o Mailing Address: City Day Telephone: Fax Number: Expiration Date: State Zip [ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record i Company Name: Cck. i \ Mailing Address: 4 -4.5, -- ) 1.w C r --ham.. ed1 l A. 1 , © 0 '"7 1O1 _ ' Ci ' state Zip Contact Person: \ 1.).4-7 r 1 ' - \ 1 Day Telephone: CI.34 - 1--1 4 S 4 .- - I TI (( E -Mail Address:_' A U,A a 4. 0 oLl, l Fax Number: [ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record state Zip Day Telephone: 1 \3- � F3 - 0 Fax Number: Page 1 of 6 BUILDING PERMIT INFO ON - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ I JC:, COCA ,, Existing Building Valuation: $ Scope of Work (please provide detailed information):' .1 o 3 a. P 3 AN e h c )s -1ro n o aD R o:te ) -1 • Will there be new rack storage? ❑ Yes Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes Department. Q:1Appticaaon&Fonos- Applications On tinev -2006 - Pamir Application.doc Reviled: 9-2006 nn 40 at -i y .. No If yes, a separate permit and plan submittal will be required. Compact: Handicap: No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will ere be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x II " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Ty pe of Occupancy per IBC I Floor 95 n (A0 �t 35 l r i p rt4 e ms.0, 1 r`' Floor 3rd Floor Floors _ thru Basement Accessory Structure' Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFO ON - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ I JC:, COCA ,, Existing Building Valuation: $ Scope of Work (please provide detailed information):' .1 o 3 a. P 3 AN e h c )s -1ro n o aD R o:te ) -1 • Will there be new rack storage? ❑ Yes Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes Department. Q:1Appticaaon&Fonos- Applications On tinev -2006 - Pamir Application.doc Reviled: 9-2006 nn 40 at -i y .. No If yes, a separate permit and plan submittal will be required. Compact: Handicap: No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will ere be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x II " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Page 2 of 6 PUBLIC WORKS PERMIT INFORMATION - 206 - 433 -0179 Scope of Work (please provide detailed information): i\ 4 Miter District ...Tukwila ❑...Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate Call before you Dig: 1-800- 424 -5555 Please refer to Public Works Bulletin #1 for fees and estimate sheet. ❑... ValVue ❑ .. Renton ❑...Sewer Availability Provided Se tie System: O On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ .. Geotechnical Report 0 ...Traffic Impact Analysis ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ .. Right -of -way Use — Potential Disturbance ❑ ...Construction/Excavation/Fill • Right -of -way Non Right -of -way ❑ ...Total Cut cubic yards ❑ ...Total Fill cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water Q:1ApplieatieunWWms- Applications Oo LinoUU- 2006 - Permit Applicatioo.doe Revised: 9-2006 Ut ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line 11 ❑ .. Highline ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Renton ❑ .. Seattle ❑ .. Grease Interceptor ❑ .. Chamtelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size .. WO # ❑ ...Water Only Meter Size WO # ❑ ...Deduct Water Meter Size " ❑ ...Sewer Main Extension Public Private _ ❑ ...Water Main Extension Public Private FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip Page 3 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Boiler /Compressor: Qty -! Fumace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0-3 HP /100,000 BTU Fumace> 100K BTU Evaporator Cooler Diffuser ' -- 3 -15 HP /500,000 BTU Floor Furnace _ Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater — Ventilation System Wood/Gas Stove -.-- 30 -50 HP /1,750,000 BTU Appliance Vent _ Hood and Duct .----- Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic .� Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator - Comm/Ind MECHANICAL PERMIT INFORMATION •- 206 - 431 -3670 MECHANICAL CONTRACTOR INFORMATION j Company Name: �� Mailing Address: Contact Person: ) b c e b-))-r4 E-Mail Address: 5l , Y7}1,t i� 1 (� c� -P��au ci o . Ccsr► Contractor Registration Number: Valuation of Mechanical work (contractor's bid price): Scope of Work (please provide detailed information): (L vti4 ,'lo, � 3r. P�C.�nri . . c�u r - tr' h, ., A \ At v (3 3 Pry i S I n - 5 .-F-R U h n , ,.l A Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .. Replacement .... ❑ Fuel Tvpe: Electric ❑ Gas....❑ Other: Indicate type of mechanical work being installed and the quantity below: QUDpIieatiamfttms- Appliatian On ►ine\3 -2006 - Permit Applieationdoc Revised: 9-2006 bh City Day Telephone: O° .. S T - FEto Zip x5 � 1 Fax Number: Qi - 9CX) - - -7Q 15 Expiration Date: Page 4 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty __ Bathtub or combination bath/shower '�� Drinking fountain or water cooler (per head) — Wash fountain Gas piping outlets Bidet 4 Food -waste grinder, commercial ` Receptor, indirect waste — Clothes washer, domestic -- Floor drain 1 Sinks (p Dental unit, cuspidor — Shower, single head trap ---- Urinals ---- Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system – per drain (inside building) Water heater and/or vent Additional medical gas inlets/outlets – six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors . Repair or alteration of water piping and/or water treating equipment — Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas PLUMBING AND GAS PIPING PERMIT INFORMATION - 206- 431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: OP � 0-6:4 L Day Telephone: € cC - ,� - 4C c (1 >B/ E -Mail Address: Fax Number: 81, (r, -Rix") Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ I L , COD • Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Int'I Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water. Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q: ApplicationsWo mrApplianom On linen -2006 - Permit Applicadoadoo Revised: 9 -2006 m Page 5 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Signature: Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND l AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: io Print Name: 7 )e ) 5L b `` Mailing Address: 1 \ C N �-1 1 5 k Q: WppticatioosWomu- Applications On tine'3 -2006 - Permit Appiicatiandoc Revised: 9 -2006 bb Date: a - - Day Telephone: 8 - - O1 7O KbB hi U \, l�71A 98033 State Zip D ate Application Accepted: Date Application Expires: Staff Initials: we i Page 6of6 Parcel No.: 6364200010 Permit Number: D08 -077 Address: 555 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 02/08/2008 Applicant: GODIVA CHOCOLATIER Issue Date: Receipt No.: R08 - 01196 Initials: WER User ID: 1655 Payee: MARKET CONTRACTORS ACCOUNT ITEM LIST: Description rinr. Raraint -(1R City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 11722 1,634.50 BUILDING - NONRES 000/322.100 STATE BUILDING SURCHARGE 000/386.904 RECEIPT Account Code Current Pmts Total: $1,634.50 Payment Amount: $1,634.50 Payment Date: 04/16/2008 09:27 AM Balance: $0.00 1,630.00 4.50 12 <<< TOTAL Printpd (14- 16-200R Project 41■ A Type of Inspection: ,..., GI Address rt n 11 Date Called: ( j q/ J Special nstructions: Date Wanted: �� / a.m. p.m. Requeste Phone No: 4 l)1 ov9 INSPECTION NO. INSPECTION RECORD Retain a copy with permit 1) c) -- PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ID Approved per applicable codes. ['Corrections required prior to approval. COMMENTS: ulk 0n Led 6nfik--4-e 7 5La..W ?A,„Kik, 1 oy Inspector: Date: ... for El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: C Q d i ✓a. Type of Inspection: Fits I Address: J J 44 Date Called: Special Instructions: Date Wanted: -7 / /7Qc' a.m. p.m. Requester: Phone No: INSPECTION RECORD pa_ 072 Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 � Approved per applicable codes. Corrections required prior to approval. COMMENTS: Pro-!t rQ h . � f / 141 Inspector: C. Date: /7 r $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: Pro e . Type of Inspection: ress: 555 /24/l Date Called: Special Instructions: Date Wanted: 9 CCn1: 7 ----- 4 p .m. Requester: Phone No: 358 -1--)6619 ) 9 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit Dag -077 PERMIT NO. Approved per applicable codes. Corrections required prior to approval. COMMENTS: r /,i} 604. - -a 7�c h &tee El $6 . REINSPECTION FEE REQUIRED. Prior to inspection, fee must be p at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: trc IY 3 � L441T' Tb _ _ . Project: i Type of Inspectio �. Address: s—ss /04// Date Called: Special Instructions: Date Wanted: 7/1 /b 1 a p.m. Requester: Phone No: SO 5 C 14 kio d` INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT N CITY OF TUKWILA BUILDING DIVISION 12- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 pproved per applicable codes. El Corrections required prior to approval. Inspectds se. I 0ate _1 /, /o r El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 Receipt No.: 'Date: ProType r . (And C &)c° of Inspection: /L , S 1.l p 'Z/ C - l Address: S Date Called: Special Instructions: Date Wanted: s - 2- 7 - oc? a.m. Requester: 7 r _0 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 al Approved per applicable codes. Corrections required prior to approval. COMMENTS: Date: S� Z Inspector: E $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: LfM1J � �.1f il�s��f� �Y9'�f11 Project: Type of Ins ection: Address: 55:5 5 //A1V.r r )?6 Date Called: // Special Instructions: Date Wanted: /C . — Ito --Qe p.m. Requester: Phone No: 503 ' 5' - 4 4 6e- 5 g INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 &A-672 PERMIT NO. it- (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. 1 1 • S COMMENTS: ,,,)/ fievcikA areas Inspector: eLl Date: 5 � 6 / D6.... , $586 EINSPECTION FEE REQUIRED. Prior o inspection. fee must be pa at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: Project: tt_ 'O rr iI v' 4 0kG6 Type of Inspection: r` aC) gAl t JV Address: SSS Yl4I1 Date Called: Special Instructions: Date Wanted: -. — 1 .. - OP (g. Requester: Phone No: )3 - ,3 58 L / ( v3 / 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #1 d0, Tukwila, WA 98188 (206)431 -3670 n Oc- -67 7 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 94 s Ok Inspector: Date: $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: ‘() Proje : Go Doty 4 Noe. Type of Inspection: -F62 Am, /∎/ Address: 555 MA 1 Date Called: Special Instructions: Date - Wanted: - 7 ` m' Requester: Phone No: 5o3 35 - 4 /68V INSPECTI N NO. CITY OF TUKWILA BUILDING DIVISION F- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit Approved per applicable codes. Corrections required prior to approval. COMMENTS: P. A- I &M l t caz , J I 1 Whfive z) R 4-16v , I') Li cc f/ritite ctor: $58.0 paid *AAA IA r INSPECTION FEE EREQUIRE Ip. Prior o inspection. fee must be 300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt Date: aP� • Date: qy.+ . _ _...i ._.Le._ ° ti a4wA eas i..: 1 ... :1vf:� r..,,.. til' Aflame' Prod t: CO OD i u 10, ker • Type of Inspection: --3- -w Address: S mar t Date Called: Special Instructions: Date Wanted a. Requester: P> ( ;s --Li bay a INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ❑ Approved per applicable codes. Corrections required prior to approval. ti COMMENTS: rm Inspecto (2.1 El El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: ,a xwar. 1 - may« -• ti »�. �s.s.. Pro' t: aD� (Ma Type Inspe jinn: t (/v* Addr : ,!( /' /70ftioc t/ d / Date e Special Instructions: Date Wanted: / ` / / 7 4_ a.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 w°' PERMIT NO. 1"� (206)431 -3670 0 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: p /1 &:; Vi e Je _/ A/Sp,,,i, ►t / 9Xe0f A(.5 Pe° dp 8.00 REINSPECTION EE REQEIIRED. Prior to inspection, fee must be aid at 6300 Southcent Blvd.. 100. Call the schedule reinspection. R=ceipt No.: Date: Date: r i :. �1e�'rdi4 tit a` ft£�'�i L18aiF Project: Go D U A (,4 DC Dt ,q,. R, Type of Inspection: Address: 5 4 . e. AA MAY Suite #: Contact Person: vvf Special Instructions: Phone No.: 533- 3, - 4C9 Needs Shift Inspection: Sprinklers: fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 4hC2.Si€S104 ^.V ti! ✓� 1 INSPECTION NUMBER 444 Andover Park East, Tukwila, Wa. 98188 ' 206 - 575 -4407 Approved per applicable codes. COMMENTS: M t,u �� u on, - U t< e ite D Inspector: Wdh /6 - 7 , fl INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT Word /Inspection Record Form.Doc 1/13/06 M O ' O3'1 bQi - iq PERMIT NUMBERS Corrections required prior to approval. $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. can to schedule a T.F.D. Form F.P. 113 Da 6/0 ' rs.. / L Project: &°6:`)161' C k O c a I k -e Y Type of Inspection: Sid .r. N oil-- Address: 6 S S. C . r^ t L L Suite #: Contact. Person: i4 S ar-/ Special Instructions: Phone No:: .. "3- 3S g- Leerif Needs Shift Inspection: to Sprinklers: Fire Alarm: Hood & Duct: rti Monitor: • Pre -Fire: Permits: Occupancy Type: _��:s�•r- �;�:w��..:�r�- rte+- ..w��: �nca� �:. �v:�n=� �-- :��r,��?: Y INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit ' CITY OF TUKWILA FIRE DEPARTMENT Aar- o� 0? - 5 - / PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 _ 206- 575 -4407 proved per applicable codes. n Corrections required prior to approval. COMMENTS: se,croc■,/ • I inspector: / s- y Date: W/108 Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 ti COMMENTS: 0 k o c 0 64- A-. Type of Inspection: - Setz ok fele. 4 N 4 L.._ Address: 5 5 Suite #: S . (. yin Lk L t-- Contact Person: Zl o Ai -- Special Instructions: Occupancy Type: Phone No.: ,, Ad o c -e. s 6 b DO SO ■ 14-4 I Av 5�,. +. e ter) 6-r a. S 4 p I A S . � f i-c rrn T F . IS 1.- • Project: 6. , U 0 k o c 0 64- A-. Type of Inspection: - Setz ok fele. 4 N 4 L.._ Address: 5 5 Suite #: S . (. yin Lk L t-- Contact Person: Zl o Ai -- Special Instructions: Occupancy Type: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: • Pre -Fire: Permits: Occupancy Type: "? ivsf..�ki ` e i :.t r ?! ?= s - 4 v = °a•.: n;: xha. w. Nr. »..� a-t:x w- -;.avN ox.: a. .VArSY .c:t s.s: 3 INSPECTION NUMBER Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TJKWILA FIRE DEPARTMENT Word /Inspection Record Form.Doc 1/13/06 I Date: • Og-- S- ; 77 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 /11_,Oarrections required prior to approval. 'Inspector: .,S Hrs.: t A 4 1411 ' $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department Call to schedule a reinspection. ti T.F.D. Form F.P.413 Project: G 0 b Li c h o c 0! A' -f : s (2 Type of Inspection: c'ove Address: ' 5 5 Suite #: - . c . iti, i L., _ _ Contact h - Special Instructions: Occupancy Type: Phone No.: 5 35P - ( {64Py , Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: :S4?3�Wr: i,N:AY 51dTi.£St'1ti:sYiri':'"y`t'�• `t V`W?o: .`s■:h ti INSPECTION NUMBER Approved per applicable codes. INSPECTION RECORD Retain a copy with permit Word /Inspection Record Forrn.Doc 1/13/06 Wig— ©77 a, - 5 -' 57 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 ri Corrections required prior to approval. COMMENTS: a.. ...._..... .. J} . . Inspector: 5 1 Date: S 1 rs .. 80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department: Call to schedule a reinspection. T.F.D. Form F.P. 113 COMMENTS: 0 ist o c v14 e k. Type of Insp ction: Address: Suite #: ',5513- S. C' Contact Person: 13.4".- C .zwc A, Permits: 4 7 D/l a p Phone No.: q)- - 76e4- 09 5 /Do c) ? a u ( Psi- ic 1 zoo C u OQ it A b Prop, '; 01-icift..- ge AR Win.) o4 A Lr4,.t ..._ ` tn 1 N ; . . ;' 7:. -. i..:. 1 :.. ..:.'a'.. _ rte' �:a.. -...-. ':keZrt 4 _ ...it::....... - ' - 7 - = -. ... . L: • _ .ti. . . ... . / .. t Project: G o a; tiA 0 ist o c v14 e k. Type of Insp ction: Address: Suite #: ',5513- S. C' Contact Person: 13.4".- C .zwc A, Permits: Special Instructions: Phone No.: q)- - 76e4- 09 Needs Shift Inspection: , Sprinklers: Fire Alarm : Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER ri Approved per applicable codes. INSPECTlON RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT Word /Inspection Record Form.Doc 1/13/06 Date: 5 v � Do - 0 — 7 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Corrections required prior to approval. Inspector: . rs.. n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from 4 the City of Tukwila Finance artment. Call to schedule a reins tion. tY �eP ec p T.F.D. Form F.P. 113 J • May 27, 2008 Mr. Roger Toth Market Contractors, Ltd. 10250 NE Max Street Portland, OR 97220 RE: In Process Inspection Report Godiva Chocolates Tukwila, WA Dear Mr. Toth, Respectfully submitted, KRAZAN & ASSOCIATES, INC Kathryn E. Gordon Project Manager Puyallup Division CC: City of Tukwila & ASSOCIATES, INC. RECEIVED GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION KA No. 066 -08080 Permit No. D08 -077 Enclosed are copies of the compressive strength test results regarding the above referenced project. If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office at (253) 939 -2500. Offices Serving The Western United States 92' V ailev Avenue NW Suite 101 • Puyallup. Washington 98371 • (253)939 -2500 • Fax: (253) 939 -22556 08080 Break fempla:e .it "1 0 2 2008 COMMUNITY DEVELOPMENT acdfl a H„uGlc/WS, nle. ../Project No. 066 -08080 Weather Cloudy Project Godiva Chocolates Location 555 Southcenter Mall Tukwila Client Market Contractors, Ltd. .=_. 2141 4SINIXEMII9 . rU... S r AA Field Data CYLINDER REPOR Concrete X Other Supplier Corliss Time 2:02pm Placement Area Location Plumbing trench. Remarks Placed by wheel barrow. Please refer to field report #82897 Inspector Joe Bauduin Laboratory Data Cyl. Code Truck# Ticket # % Air 114 38836 Test Date 80509 -1 5/1/2008 80509 -2 5/22/2008 80509 -3 5/22/2008 80509 -4 80509 -5 80509 -6 80509 -7 80509 -7 Remarks Results Reviewed By Field Cure Plant No. 2 Age Dim. Area 7 4.014 12.65 28 4.007 1 2.58 28 4.007 12.58 H ycc vdutMvenue ivvv, aulte iu 1, ruyauup, VVH, Uo. i I, (zao) uotl Cyl. Code 80509 Pour Date 4/24/2008 Jurisdiction City of Tukwila "'h9=1i CI.V..' , :c. w 'a1319111110 Y 4=3•'t A.. to AM CII JA4 r • Site Mix Mix Air Slump Temp. Temp. (in.) (F) (F) 4 56 55 Design Strength 3,000 @ 28 days Engineer Architect Contractor Market Contractors Unit Wt. (pcf) Permit No. D08 -077 Date Reviewed 37 Codes for Break Types: 1: Cone 2: Core & Split Measurement Uncertainties: ASTM C -39 +1- 8% Form 03101 Revision 3 Effective Date 5e1210 The information provided on this wort 5 prepared 'or the n dusr.•e ,se of Iho , Alert Pas rop..t may wt Se reproduced in any fn, mai without the written penmss.on of the dwnt and Kronen 8 Asao'ci• Report No. 21299 Reported Batch Data Design Actual Weights We'jhts Mix No. P13010 P13010 Cem. lbs. F. Ash lbs. NO BATCH WEIGHTS C. agg. lbs. 1 C. agg. lbs. 2 C. agg. lbs. 3 Sand lbs. Water lbs. Air Ent. (oz) Other (oz) Other (oz) Other (oz) Other (oz) Water Added on Job (gals.) Field Test Methods X ASTM C143 ASTM C138 X ASTM C1064 ASTM C173 X ASTM C31 ASTM C172 OTHER ASTM C231 Date Specimens Rec'd. Max. Comp. Tested Break C.F. Load Str. (psi) Set # By Type 48565 3,840 SS 57880 4,600 MT 58165 4,620 MT Laboratory Test Methods X ASTM C39 ASTM C109 ASTM C617 X ASTM C1231 ASTM C780 Other Test Results X Conforming Non - Conforming 3: Cone & Shear 4: Shear 5: Columnar (Split) v .4�� r • 04/25/08 Dave Larson Department of Community Development 6300 Southcenter Blvd., #100 Tukwila, WA 98188 RE: Godiva Chocolatier Southcenter Mall Tukwila, WA Dave- In regards to the project listed above, this letter is to verify that the platform /ceiling framing above the restroom, as currently designed -18 ga. 6" mtl studs @ 16" o.c. wI %" plywood deck, will support the dead /point load of the specified transformer ( +/ - <400 lbs). Please contact me if you have any questions. Thank you ECEIVEr APR 2 8 2008 PERMIT CENTEFh to EC VE A, " ►� 2 2009 DE 4RTM Page 1 of 1 MODA4 Design 1 4325 Tam 0 Shanter Way, Dayton, OH 45429 I p: 937.477.2334 I f 937.299.0577 I info @moda4.com 04/25/08 Dave Larson Department of Community Development 6300 Southcenter Blvd., #100 TL.kwila, WA 98188 RE: Godiva Chocolatier Southcenter Mall Tukwila, WA Dave- In regards to the project listed above, this letter is to verify that the platform /ceiling framing above the restroom, as currently designed -18 ga. 6" mtl studs @ 16" o.c. w/'/<" plywood deck, will support the dead /point load of the specified transformer ( +/ - <400 Ibs). Please contact me if you have any questions. Thank you RECEIVED ApR 2 8 2008 PERMIT CENTER Page 1 of 1 MODA4 Design 1 4325 Tam 0 Shanter Way, Dayton, OH 45429 I p: 937.477.2334 I f: 937.299.0577 I info @moda4.com Project Info Project Address Godiva Chocolatier - Southcenter Mall Date 1/24/2008 633 Southoenter, Suite 1020 For Building Department Use Seattle, wit 98188 Applicant Name: Applicant Address: Applicant Phone: 2006 Washington State Nonresidential Energy Code Compliance Form Project Summary PRJ -SUM 2008 Washington State Nonresidential Energy Code Compliance Fors Flli.e c permit N s Ups -o77 I3XP 11/07/08 Revised July 2007 REVIEWED FOR CODE COMPLIANCE PROVE FEB 1 q 2008 City Of Tukwila BUILDIN DIVISI N RECEIVEF FEB' -8 2008 PERMIT CENTER Cooling Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btu/h Total CFM OSA CFM , or Econo? SEER or EER IPLV Location SCrJ /C°- 1 CARRIER FA4CNF024 /24ABR324 19900 835 VAV 13.00 Fan Equipment Schedule Equip. ID Brand Name Model No. CFM SP' HP/BHP Flow Control Location of Service VAV -1 TITUS DTQS 1035 0 .35 0.25 VAV LAC -1A Heating Equipment Schedule Equip. ID Brand Name' Model No. Capacity2 Btu/h Total CFM OSA ctm or Econo? Input Btuh Output Btuh Efficiency' Project Info Project Address Codiva Chocolatier - Southcenter Mall Date 1/24/2008 633 Southoenter, suite 1020 For Building Dept.. Use Seattle, WA 98188 Applicant Name: Applicant Address: Applicant Phone: 2006 Washington State Nonresidential Energy Code Corn • fiance Form Mechanical StOrnary MECH -SUM 2008 Washington State Nonresidential Energy Code Compliance Forms RmMmdJuly2007 Project Description Briefly describe mechanical system type and features. Includes Plans Drawings must contain notes requireing compliance with commissioning requirements - Section 1416 Compliance Option QQ Simple System 0 Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH-SLIM for simple & complex systems.) Equipment Schedules The following information is required to be Incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill In the required information below. 3 if requIr56 4 COP, HSPF Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable ar co nstant m0/(CVf variable speed (VS). 'If available. 2 As tested according to Table 14-1A through 14-1G. • it a r ' 1 System Description See Section 1421 for full description of Simple System qualifications. If Heating/Cooling or Cooling Only: ❑ Constant vol? ❑ Alr cooled? ❑ Packaged sys? ❑ <20,000 Btuh? ❑ Economizer included? ,, Split system? If Heating Only: ❑ <5000 cfm? ❑ <70% outside air? a Heating Only 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary (back) MECH -SUM Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. otai Ca.. wo economize <240,000 Btuh or 10 %? ( Reference 11 Section 1421 Heating /Cooling or Cooling Only Yes Reference Section 1423 Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project Mechanical Permit Plans Checklist 2006 Washington State Nonresidential Energy Code Compliance Forms - ' MECH -CHK ReNsed July 2007 Project Address Sodium Chocolatier - sout:hcenter Mall Date 1/24/2008 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements In the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) 1 Code Section 'Component (Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance n.a. 1411.4 Pkg. elec. htg.& dg. List heat pumps on schedule yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency a. a. 1411,1 Combustion htg. Indicate Intermittent ignition, flue/draft damper & jacket loss 1412 HVAC controls - - yes 1412.1 Temperature zones Indicate locations on plans yes 1412.2 Deadband control Indicate 5 degree deadband minimum z> . a. 1412.3 Humidity control Indicate humidistat n.a. 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types n. a 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage a . a . 1412.4.2 Optimum Start indicate optimum start controls a. a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule n. a. 1412.6 Combustion htg. Indicate modulating or staged control yes 1412.7 Balancing Indicate balancing features on plans 1412.8 Ventilation Control Indicate demand control ventilation for high -occupancy areas n.a. 1422 Thermostat interlock Indicate thermostat interlock on plans n.a. 1423 Economizers Equipment schedule 1413 Air economizers a. a. 1413.1 Air Econo Operation Indicate 100% capability on schedule n . a . 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb a. a. 1413.2 Water Econo Doc Indicate cig load & water econoe & cig tower performance n. a. 1413.3 Integrated operation Indicate capability for partial cooling n.a. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems yes 1414.1 Duct sealing Indicate seating necessary yes 1414.2 Duct insulation Indicate R -value of Insulation on duct yea 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements n.a. 1416.2.1 Commissioning Provide commissioning plan yea 1416.2.2 -3, Sys.Bal & Func.Test Indicate air and water system balancing & functional testing yes 1416.2,4 Commissioning Indicate O&M manuals, record drawings, staff training n.a. 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report yes 1434 Separate air sys. Indicate separate systems on plans yes Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency. din, hp, economizer I SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. yes 1441 Elec. water heater Indicate R -10 Insulation under tank yes 1442 Shut-off controls Indicate automatic shut -off yes 1443 Pipe Insulation Indicate R -value of insulation on piping n. a 1452 Heat Pump COP Indicate minimum COP of 4.0 a. a . 1452 Heater Efficiency Indicate pool heater efficiency n. a 1453 Pool heater controls Indicate switch and 65 degree control n. a. 1454 Pool covers Indicate vapor retardant cover n.a. 1454 Pools 90+ degrees Indicate R -12 pool cover 2006 Washington State Nonresidential Energy Code Compliance Form no is circled for any question, provide explanation: • 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist MECH -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14.1A through 14 -1G. If a nationally recognized certification program exists for a product covered in Tables 14 -1A through 14 -1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu/h (65 kW) and all unit heaters shall also have an Intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with Input ratings > 225,000 Btu/h (85 kW), Including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the Input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packag equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu/h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of e building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if In the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and Include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu/h) or less may be controlled by readily accessible manual off-hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories In height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 1412.8 Ventilation Controls for High -Occupancy Areas: Demand control ventilation (DCV) Is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 efm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct- digital control of Individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cim. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement Is,iess than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception Is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following Information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shag be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water -cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer Is required one cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246- 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadlabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 Inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating Interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include Insulation installation, moisture control, air leakage. and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating Interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 • 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist MECH -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14.1A through 14 -1G. If a nationally recognized certification program exists for a product covered in Tables 14 -1A through 14 -1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu/h (65 kW) and all unit heaters shall also have an Intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with Input ratings > 225,000 Btu/h (85 kW), Including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the Input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packag equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu/h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of e building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if In the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and Include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu/h) or less may be controlled by readily accessible manual off-hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories In height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 1412.8 Ventilation Controls for High -Occupancy Areas: Demand control ventilation (DCV) Is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 efm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct- digital control of Individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cim. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement Is,iess than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception Is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following Information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shag be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water -cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer Is required one cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246- 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadlabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 Inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating Interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include Insulation installation, moisture control, air leakage. and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating Interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying 2006 Washington State Nonresidential Energy Code Compliance Form 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 2. are isolated from the exterior with an automatic shut-off damper complying air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum with Section 1412.4.1. start controls shall be designed to automatically adjust the start time of an HVAC Once outside air ducts meet the above listed requirements, any runs within system each day to bring the space to desired occupied temperature levels conditioned space shall comply with Table 14 -5 requirements. Immediately before scheduled occupancy, The control algorithm shall, as a Other ducts and plenums shall be thermally insulated per Table 14-5. minimum, be a function of the difference between space temperature and occupied Exceptions: setpolnt and the amount of time prior to scheduled occupancy. 1. Within the HVAC equipment. 1412.6 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set- 2. Exhaust air ducts not subject to condensation. up, and defrost conditions. These controls shall anticipate need for heat and use 3. Exposed ductwork within a zone that serves that zone. compression heating as the first stage of heat. Controls shell indicate when 1415 Piping Systems supplemental heating is being used through visual means (e.g., LED indicators). 1416.1 Insulation: Piping shall be thermally insulated in accordance with Table 14-6. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment Exception: Piping installed within unitary HVAC equipment. with a capacity over 225,000 Btufh shall have modulating or staged combustion Water pipes outside the conditioned space shall be insulated in accordance with control. 000 Washington State Plumbing Code (WAC 51 -28) EXCEPTIONS: 1. Bolters. 2. Radiant heaters. 1416 Corn pletlon Requirements (Refer to NREC Section 1418 and the Building 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have Commissioning Guidelines, published by the Building Commissioning Association, a means for balancing, including but not limited to, dampers, temperature and for complete text and guidelines for building completion and commissioning pressure test connections and balancing valves. requirements.) Opaque Concrete /Masonry Wall Requirements Wall Maximum U- factor is 0.15 (R5.7 continuous ins) CMU block walls with insulated cores comply If project qualifies for Concrete /Masonry Option, list walls with HC 2 9.0 Btu/R'••F below (other walls must meet Opaque Wall requirements). Use descriptions and values from Table 10-9 in the Code. Wall Description (including Ins lation)up f oton) U- factor Date + ` 1 ,207.4, -- S L0D .? t. ,y For Buil ng D1partr ent Use FILE MP itrfrj ,, o tt�W .� / N/ tB I 20 f t 4 Sri ! x ,.. ' pplicant Name: • l FEB —8 Za s aERMVIIT CI Applicant Phone: �2� ����- V Project Info O Electric resistance 0 All other (see over for definitions) Project Address 5 ‘D ._1� _ L" v ' Cy` j Total Glazing Area Electronic version: these values are automatically taken from ENV -UA -1. (rough opening) Gross Exterior (vertical & overhd) divided by Wall Area times 100 equals % Glazing _ X 100 = Date + ` 1 ,207.4, -- S O yes Check here if using semi - heated path and if project meets all requirements for semi - heated spaces Semi- Heated Path O no as defined in section 1310. Requires other fuel heating and qualifying thermostat. Only wall insulation requirement is reduced (2008 change). Only available in prescriptive path. For Buil ng D1partr ent Use FILE MP itrfrj ,, o tt�W .� / N/ ` ,.. ' pplicant Name: • l Applicant Address: 1 t - _ _ _ ( l 1 ?�t V(v� �� Applicant Phone: �2� ����- V ' Space Heat Type O Electric resistance 0 All other (see over for definitions) Glazing Area Calculation Note: Below grade walls may be included in the Gross Exterior Wall Area if they are insulated to the level required for opaque walls. Total Glazing Area Electronic version: these values are automatically taken from ENV -UA -1. (rough opening) Gross Exterior (vertical & overhd) divided by Wall Area times 100 equals % Glazing _ X 100 = Concrete as0 Option llry p on 0 yes Check here if using this option and if project meets all requirements for the Concrete/Masonry Option. See Decision Flowchart (over) for qualifications. Enter requirements for each qualifying O no assembly below. O yes Check here if using semi - heated path and if project meets all requirements for semi - heated spaces Semi- Heated Path O no as defined in section 1310. Requires other fuel heating and qualifying thermostat. Only wall insulation requirement is reduced (2008 change). Only available in prescriptive path. CITY OF TUKWILA - BUILDING DIVISION ■ 2006 Washin • ton State Nonresidential Ener Code Com fiance Form Enyse { ; 3 _J_� • 2000 Washington State Nonresidential Energy Code Compliance Forms l'roj�c Description 9t New Building ❑ Addition ❑ Alteration ❑ Change of Use Compliance Option ❑ Prescriptive ❑ Component Performance (See Decision Flowchart (over) for qualifications) ❑ Seattle EnvStd ❑ Systems Analysis Envelope Requirements (enter values as applicable) Roofs Over Attic All Other Roofs Opaque Walls' Below Grade Walls Floors Over Unconditioned Space Slabs -on -Grade Radiant Floors Opaque Doors Vertical Glazing Overhead Glazing Vertical/Overhead Glazing Notes: Minimum Insulation R- values Maximum U- factors Maximum SHGC 1. Assemblies with metal framing must comply with overall U 9 9 REGISTE ARCHIT kSON C. SHEE OF O Revised July 2007 tO8OE77 08 ITER CITY OF TUKWILA - BUILDING DIVISION 2006 Washin • ton State Nonresidential Ene Code Corn • liance Form S t'A4:t,tFt:J-e - - . 2008 Washington State Nonresidential Energy Code Compliance Forms Decision Flowchart for Prescriptive Option Use this flowchart to determine if project qualifies for the optional Prescriptive Option. If not, either the Component Performance or Systems Analysis Options must be used. 1302 Space Heat Type: For the purpose of determining building envelope requirements, the following two categories comprise all apace heating types: Other. All other space heating systems including gas. solid fuel, oa, and propane space heating systems and those systems listed in the exception to Means resistance (contnued at right) 4 V All Insulation Installed? Below Grd Wall (ext) Below Grd Wall (oth) Roof Over Attic All Other Roof Raised Floor Slab -On -Grade Radiant Floor Opaque Door R -10 R -19 R -30 R -21 R -19 R -10 R -10 U -0.60 No L Mass Wall Criteria OK? (below) Yes AG Mass Wall Insulation Req. Mass Wall CMU Block Wood Frame Metal Framed U0- 151R5.7d Ins. Cores R19 R19 No tie V Yes Glazing Criteria Met? Glazing Vert OH Area % UVal UVal SHGC 0-30% 0.55 0.70 0.45 30-45% 0.45 0.60 0.40 >45% Not Allowed { Yes Glazing Area % 0-30% >30 Prescriptive Path Allowed Component Performance, Systems Analysis, or EnvStd Required Electdc Resistance: Space heating systems which use electric resistance elements as the primary healing system inducting baseboard, radiant, and forced as units whore the total electric resistance heat capacity exceeds 1 0 wm' of the gross conditioned floor area Exception: Heat pumps and terminal electric resistance heating in variable as volume distribution systems Yes V All Insulation Installed? Below Grd Wall (ext) Below Grd Wall (oth) Roof Over Attic All Other Roof Raised Floor Slab -On -Grade Radiant Floor Opaque Door Wood R -10 R -19 R -38 R -30 R -30 R -10 R -10 U-0.80 Metal R -10 U -0.062 U -0.031 U -0.034 U -0.029 R -10 R -10 U o Y Yes Yes— Glazing Criteria Met? Vert OH UVal UVal SHGC 0.40 0.60 0.40 Not Allowed Yes No 4—J Yes V AG Mass Wall Insulation Req. Mass Wall U0.15/R5.7d CMU Block Ins. Cores Wood Frame R19 Metal Framed U0.082 Concrete/Masonry Option* Assembly Description Wall Heat Capacity (HC) Assy.Tag HC** Area (sf) HC x Area Revised July 2007 No-- No--► if the area weighted heat capacity (HC) of the total above grade wall is a minimum of 9.0, the Concrete Masonry Option may be used. For framed walls, assume HC =1.0 unless calculations are provided; for all other walls, use Section 1009. Project Address Date Space Heat Type 0 Electric resistance 0 All other For Building Department Use Glazing Area as % gross exterior wall area Prop. I Max.Target Concrete/Masonry Option 0 Yes 0 No Notes: If glazing area exceeds maximum allowed in Table, then calculate adjusted areas on back (over). Building Component List components by assembly ID & page # Proposed UA U- factor x Area (A) = UA (U x A) Target UA U- factor x Area (A) = UA (U x A) 6uizel0 Ripen U= Plan ID: U= Plan ID• U= Plan ID: U= Plan ID: U= Plan ID: U= Plan ID: U= Plan ID: Glazing % Electric Resist. Other Heating • 0-30% 0.40 0.55 >30 -45% dee note above 0.45 I Overhead Glazing s31UN JOAfl 0= Plan ID: U= Plan ID: U= Plan ID: U= Plan ID: : Glazing % Electric "Resist. Other Heating 0=30% • 0.6 0.7 >30 -45% see note above 0.6 J S400)!I'llA U= Plan ID: U= Plan ID: U= Plan ID: U= Plan ID: • woo anbedo U= Plan ID: U= Plan ID: U= Plan ID: .. .Electric Resist. Other Heating 0:60' 0:60 - JOAO I sjooa R= Plan ID: R= Plan ID: R= Plan ID: ' . - ElectriclResist. :Other Heating 0.031 0.036 SjOakj I R= Plan ID: R= Plan ID: R= Plan ID: Electric Resist. Other Heating 0.034 0.046 . apo ,slleM anbedo IajMOlaB R= Plan ID: R= Plan ID: R= Plan ID: R= Plan ID: R= Plan ID: R= Plan ID: R= Plan ID: 'Note: sum of Target Areas here should equal Target Opaque Wall Area (see back) ++ +. Electric Resist. Other Heating Frame -Wd . 0.062 0.062 m Frae -Mtl 0.062 0.109 Vlass War 0.15 0.15 ++ see mass wall Criteria. Plan ID: R= Plan ID: R= Plan ID: Note: if insulated to levels required for opaque walls, list above with opaque walls • - ` . . Electric Resist. Other Heating .Int Iris . 0.062 0.062 Ext'ins. 0.07 0.07 JOAO sJooU R= Plan 10: R= Plan ID: R= Plan ID: R= Plan ID: Electric Resist. Other Heating '0 :029 0.056 . R= apeJ6 -uo-geis Plan ID: R= Plan ID: R= Plan ID: R= Plan ID: _ Electric Resist. Other Heating F =0.54 F =0.54 (see Table 13 -1 for radiant floor values) For CMU walls, indicate core insulation material. Totals) Totals' 20.. a 1. .l _ alculation rte 2006 Washington State Nonresidential Energy Code Compliance Fos o comply: to .nreside, ial E e . Co•e Co ,. . r ,Iirnate Zon En / to V -UA 1) Proposed Total UA shall not exceed Target Total UA. 2) Proposed Total Area shall equal Target Total Area. Revised ,My 2007 Glazing List components by assembly ID & page # Proposed SHGC SHGC' x Area (A) = SHGC x A Target SHGC SHGC x Area (A) = SHGC x A 6uwze�� ID: ID: ID: ID: ID: ID: Glazing .% Electric Resist: Other Heating 0-30% 0.4 0.45 >30 -45% not allowed 0.4 'Note: Manufacturer's SC may be used in lieu of Totals Totals - 2006 Washington State Nonresidential Energy Code Compliance Forms For compliance: Proposed total SHGC x A shall not exceed Target total SHGC x A NOTE: Since 1997 SHGC compliance for vertical and overhead glazing is allowed to be calculated together. arge siea °Adjustment Calculation Glazing Area Opaque Area Gross Exterior Well Area l IXI I =I 100 1 =1 Roots over Attics Other Roofs Walls If the total amount of glazing area as a 96 of gross exterior watt area (calculated on ENV•SUM1) exceeds the maximum allowed In Table 13 -1, then this calculation must be submitted Use the resulting areas In the Target UA and SHGC calculations above Proposed Areas: Numbered values are used in calculations below. Roofs over Attics Other Roots Wails OG= OG= VG= Max Glazing Area (Table 13 -1) 8 lesser Proposed Opaque Area 8Wast' •toIS =ekot = _•_t'a _te. C..eC•t 'let - imate Zo:n. Target OG Area In Roofs over Attics Target 00 Area In Other Roofs Max OG Remaining 1 I Proposed OG Area y Target 00 Areal Target Opaque Area Proposed VG Area Maximum Target Glazing Area u lesser Proposed Opaque Area + 1 I - 1 1 Note' If there Is more than one type of wall, the Target VG Area may be distributed among them, and separate Target Opaque Areas found. If the Target Areas for Opaque Walls fisted on the front must equal the total calculated here Target VG Area Target VG Area Target Opaque Area Revised Judy 2007 Note: OG = overhead glazing VG = vertical glazing For Target OG's, the lesser values are used both here and below. Target Areas OK I Target values in shaded boxes are used In the applicable Target UA calculations on the front. Target VG Area and Total Target OG Area are also used in the applicable Target SHGC calculations above Location (floor /room no.) Fixture Description Number of Rxtures Watts/ Fixture Watts Proposed 101 Type 82 - Semi - Recessed Adjustable Fixture 6 • 40.0 240.0 176.0 101 Type SA - 6" Square Adjustable Fixture 101 Type SD - 6" Square Downlight CODE C 3^ 44 , n 88.0 101 Type PA - Pendant - Exempt per Table 15 -1, Footnote 10 A���]8v� rp�,r � C 1093.3 101 Type B2A - Semi — Recessed Adjustable Fixture 44 0 88.0 102 Typo SR - 4' Linear Channel Fixture FpR 5, „ 58.0 � ^^ 290.0 103 Type SC - Fan /Light Combo u ; 1 Luui 60 0 60.0 101 Type B2 - Exempt per 1512.1 - Food Prep Area � / 4 • 101 Type B2 - Exempt per Table 15 -1, Footnote 10 � o k S ING II r1/TCTnaI Location (floor/room no.) Occupancy Description Allowed Watts per ft Area in ft Allowed x Area Sales Area 101 Retail Sales Area 1.50 645.0 967.5 Stockroom 102 Stockroom attached to main Sales Floor 0.50 162.0 81.0 Restroom 103 Restroom 0.8 56.0 44.8 ** From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 1093.3 2006 Washington State Nonresidential Energy Code Compliance Forms 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary LTG -INT Revised July 2007 Project Info Project Address Godiva Chocolatier - Southcenter Mall 633 Southcenter, Suite 1020 Seattle, WA 98188 Applicant Name: Applicant Address: ra Applicant Phone: Date 1/24/2008 For Building Department Use FILE C PI Project Description ❑ New Building ❑ Addition 0 Alteration ❑ Plans Induded Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option Q Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not Increased, & space use not changed. Maximum Allowed Lighting Wattage Proposed Lighting Wattage otal Allowed Watts for Interior RECEIVED FEB' - 8 2008 PERMIT CENTER Total Proposed Watts Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps In the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture b 942.0 Use LPA` (W /sf) Use' LPA` (W /sf) Automotive facility 0.9 Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks. churches) " 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations" 1.0 Cafeterias, fast food establishment?, restaurants/bars 1.3 Post office 1.1 Dormitory 1.0 Ratail retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia", assembly spaces" 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group I -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel/motel 1.0 Warehouses ", storage areas 0.5 Hotel banquet/conference /exhibition half" 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbles (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers Q Other Qualification Checklist Note: If occupancy type is Other and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. if not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) 4 Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5 -60 watt T -1, T -2, T-4, T -5. T-8 lamps, and d) hard -wired elect tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary (back) LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 -1 Unit Lightin Power Allowance LPA'` Footno f o r Ta ble 15 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft with full height partitions, a Unit Lighting Power Allowance of 1.10 w/ft may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W/ft 10) Display window illumination Installed within 2 feet of the window, provided that the display window Is separated from the retail space by walls or at least three - quarter - height partitions (transparent or opaque). and lighting for free- standing display where the lighting moves with the display are exempt An additional 1.5 w /ft of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only If the lighting Is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. Tradable Locations Description Allowed Watts per ft or per If Area (ft perimeter (If) or # of items Allowed Watts x ft (or x If) Seattle, WA 98188 Name: Appl. Name Appl. Phone Project Description J New ❑ Addition ❑Alteration Plans Inducted Indicate controls (Sections 1513) including commissioning • Compliance Option Q Lighting Power Allowance 0 Systems Analysis Building Grounds (luminaires > 100 Watts) ❑ Efficacy > 60 lumens/VV ❑ Controlled by motion Sensor Exemption (list) - Non - Tradable Locations ., v Description Allowed Watts per ft or per If Area (ft perimeter (If) or # of items Allowed Watts x ft (or x If) Seattle, WA 98188 Name: Appl. Name Appl. Phone Project Description J New ❑ Addition ❑Alteration Plans Inducted Indicate controls (Sections 1513) including commissioning • Compliance Option Q Lighting Power Allowance 0 Systems Analysis Building Grounds (luminaires > 100 Watts) ❑ Efficacy > 60 lumens/VV ❑ Controlled by motion Sensor Exemption (list) Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Seattle, WA 98188 Name: Appl. Name Appl. Phone Project Description J New ❑ Addition ❑Alteration Plans Inducted Indicate controls (Sections 1513) including commissioning • Compliance Option Q Lighting Power Allowance 0 Systems Analysis Building Grounds (luminaires > 100 Watts) ❑ Efficacy > 60 lumens/VV ❑ Controlled by motion Sensor Exemption (list) Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Seattle, WA 98188 Name: Appl. Name Appl. Phone Project Description J New ❑ Addition ❑Alteration Plans Inducted Indicate controls (Sections 1513) including commissioning requirements on plans. Compliance Option Q Lighting Power Allowance 0 Systems Analysis Building Grounds (luminaires > 100 Watts) ❑ Efficacy > 60 lumens/VV ❑ Controlled by motion Sensor Exemption (list) Project Info Proj Addres: ve Chocolatier - Southcenter Mall Date 1/24/2008 633 Southcenter, Suite 1020 For Building Department Use Seattle, WA 98188 Name: Appl. Name Appl. Phone Project Description J New ❑ Addition ❑Alteration Plans Inducted Indicate controls (Sections 1513) including commissioning requirements on plans. Compliance Option Q Lighting Power Allowance 0 Systems Analysis Building Grounds (luminaires > 100 Watts) ❑ Efficacy > 60 lumens/VV ❑ Controlled by motion Sensor Exemption (list) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. 2006 Washington State Nonresidential Energy Code Compliance Forms 2006 Washington State Nonresidential Energy Code Compliance Form Exterior Lighting Summary LTG -EXT Tradable Maximum Allowed Lighting W Tradable Proposed Lightin g y Wattae or Extenor Non - Tradable Maximum Allowed Lighting Wattage Non - Tradable Proposed Lighting Wattage r Category otal Allowed Watts Use mfgr listed maximum input wattage. For fixtures with hard -wired ballasts only, the default table In the NREC Technical Reference Manual ma also be used otal Proposed Watts Lighting, Motor, and Transformer Permit Plan Checklist LTG -CHK 2008 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address Godiva Chocolatier - Southcenter Mall Date 1/24/2008 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Ene gy Code. Applicability (yes, no, n.a.) I Code Section Component information Required I Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control/access Schedule with type, indicate locations E - 2.0 yes 1513.2 Area controls Maximum limit per switch E - 2.0 no 1513.3 Daylight zone control Schedule with type and features, indicate locations no vertical glazing Indicate vertical glazing on plans No daylighting no overhead glazing Indicate overhead glazing on plans No overhead glazing yes 1513.4 Display /exhib /special indicate separate controls E -2.0 1513.5 Exterior shut -off Schedule with type and features, indicate location no (a) timer w/backup Indicate location No exterior ltg no (b) photocell. Indicate location No exterior ltg 1513.6 Inter. auto shut -off Indicate location no 1513.6.1 (a) occup. sensors Schedule with type and locations Controlled by contactor and switches yes 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans E -2.0 Contactor Cl no 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes I 1514 IMax. watts Indicate watts for each exit sign E - 1.0 I LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture Attached no 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture No exterior ltg MOTORS (Section 1511) no 1511 IElec motor efficiency MECH -MOT or Equipment Schedule with hp, rpm, efficiency I INo motors over lbp TRANSFORMERS (Section 1540) yes 1540 Transformers Indicate size and efficiency E- 2.1,E. 4.0 TP1 2006 Washington State Nonresidential Energy Code Compliance Form no is circled for any question, provide explanation: D B 8 A FIXTURE SCHEDULE WALL FIXTURES FLOOR FIXTURES ,EQUIPMENT REFSTA1COS SU8 901f W/ HALO FIEESTUmc SAS SELF O DA IOT • =SOX FEESTIROM 100-SAB SELF 11/ RAW REESTAICOC SAS SRC 1000E IAT 0 UORBOt ma CARAT B ALOAA SLAB SELF MR! PROMO) 10A, 111A310R FRAMES MOM O EIEVATIDII OSA RARER SO WEE SLA REDISTER COLORER (SMALL SAO SIX BY SCE RAMER CORKER VARES PER HEED OP SIOEFROR OPP910 UOT DOOIT HALED WRXSA1RR) OP SCREAM OHOC WIT pm XAICED NE101RA110O SELF 11AAT CASE O RESSIEA COWES - 24 SELF 11XAT CASE 0 REAM COURIER - IC 513F 11EAT CASE REESTI COS DISPLAY REFRISDIATER FM LIEN OOERWAIRR REF102IIAT01 OOFFCOIMIER COPAL" FREEZER ICE CAME 1OA 2• 0 04 'CAIE0 1001E ORAO1 SDI 0 RADII WHEW FAUCET WATERT 511( �I B 6 03C l A Oar 1tlb SICOOERS 13 SPACE SUER 310- 10 -3 -12 /01-10- IiU -3-1 113- 10 -N-S -1 41116 -1 -120 v L • WNER SUPPLIED ACCESSORY SCHEDULE GODNA SUPPLIED RESTROOU ACCESSORIES & PLUMBING FD(IURES SYMBOL KEY 10' FAUCET USE AT 10188 00/L AND IWID Sib( USE AT THREE 80I1 AND TWO SDOC 18X36 M10 307120 MST (WOES EXISTING REMOTE STOCK ROOM 03 FIXTURE FLOOR PLAN -NO-CHANGES-SHALL-BE -MADE WITHOUT HEALTH DEPARTMENT APPROVAL 1x...�; )l : :N1NG INSPECTION BY :. COUNTY HEALTH :Ss REQUIRED PRIOR APPLICANT PLAT • TO EE AVAILABLE s r INSPECTION. ECTION. @ 11 ; ;;; mss : 71µ;a`.: t,.., .:lalt3F. APPLICANT RECEIVED COPY JAN 14 2 ALDER SQUARE 02 FIXTURE FLOOR PLAN JAN 22 2000 DIANE A ASID "boo)" >;17 LLS`4101 FOIL fir . r 3 10 ISSUED /REVISED DATE HEALTH DEPT SUBMITTAL 12.17 07 NIA OWNER REVIEW 01 03.08 HEALTH DEPT RVSNS 01 11 OS FIXTURE PLAN F -1.0 77 a a 5 8 = R • x 0 • 00 8 • CRAiNabAROS,i/TENSic RACKS, OR TABLES ,LARGE ENOUGH TO ACCOMMODATE ALL SOILED AND CLEANED;; , ITEMS SHALL BE PROVIDED FOR, NECESSARY UTENSIL HOLDING ..BEFORE CLEANING AND AFTER SANITIZING PLUMBING SYSTEMS' SHALL BE DESIGNED, CONSTRUCTED INSTALLED AccoRdmicTo/.41)A (APPLICABLE LOCAL,,, STATE AND FEDERAL STATUES, REGULATIONSAND ORDINANCES) 2 J . . • • • ' BE ADVI THAT THE NEW WASHINGTON STATE FOOD cook REQUIRES • COMMERCIAL REFRIGERATION TO 'How' FOOD AT 41 DEGREES FAHRENHEIT OR • BELOW IN (DOVVN FROM 45 DEGREES). RESTROOM & KITCHEN HAND WASH' SINKS SHALL EQUIPPED TO PROVIDE WATER ATATENIPERATUkE OF AT LEASTIO0 DEGREES FAHRENHEIT tHROUdii MIXING VALVE OR COMBINATIONFAUCET SELF CLOSING OR METERING FAUCETS SHALL PROVIDE FLOW OF WATER FOR AT LEASt 15 SECONDS. • , • (Food equipment that is certified for sinitatiOn • by Atherican Natiddai StaiidaidS Institute (ANSIEadcreditad certification ogram (NSF;' Approved) wifi badednied to comply with`the: food code equipment & UtenSilinateriala; construction add deSign:re0iiremdiits. LOCKERS OR OTHER SUITABLE FACILITIES SHALL BE PROVIDED FOR THE ORDERLY STORAGE OF ; „EiVOLOVEkt'loCCili POSSESSIONS: „,- HOT WATEi2GENERATION AND ;DISTRIBUTION SYSTEMS SHALL"BE: SUFFICIENT TO MEET THE PEAK HOT ." WATER DEMANDS TkFiouciiOvi FOOD ESTABLISHMENT. - • . _ • - FOOD SERVICE OPERA TION AREA FLOORS FLOOR COVE/Olds; WALLS; WALL COVERINGS, AND CEILINGS SHALL BE DESIGNED, CONSTRUCTED "A kb INSTALLED • SO THEY ARE tifeicii Afid EA CLEANABLE . , • DEPARTMENTS: �� ti- ( or) B Iding )NISI n Publ IndINlora Complete Comments: Documents/routing slip.doc 2 -28 -02 � PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D08 -077 DATE: 02 -08 -08 PROJECT NAME: GODIVA CHOCOLATIER SITE ADDRESS: 555 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued REVIEWER'S INITIALS: Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS RO TING: Please Route Structural Review Required ❑ No further Review Required APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: 61 I tAJ(, 2 'Iz -oq, Fire Prevention v8 n � eZ_1Z - lannin Division Permit Coordinator DUE DATE: 02 -12 -08 DATE: DATE: Not Applicable rv L�� DUE DATE: 03-11-08 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: GODIVA Chocolatler February 15, 2008 Tukwila Building Division /Permit Center 6300 Southcenter B1, Suite 100 Tukwila, WA 98188 Tenant improvement permit for GODIVA Chocolatier, Inc., Tukwila Permit No. D08 -077 is issued subject to the following conditions: Final inspection approval of this permit and approval of occupancy for the herein named tenant space will not be issued until the "Shell Building Permit No. D06 -147" has received final inspection approval from the Building Division. This condition is hereby acknowledged by: Title: Tenant Name: www.godiva.com • • GODIVA Chocolatier, Inc., Godiva Chocolatier, Inc. I Meridian Boulevard Suite 3C -I P.O. Box 7000 Wyomissing, PA 19610 Manager Retail Construction Kind of Fixture Fixture Units No. of ixtures Total Fixture Units Public Private Public Private Bathtub and Shower 4 4 Shower, per head 2 2 Dishwasher 2 2 Drinking fountain (each head) 1 .5 Hose bibb (interior) 2.5 2.5 Clotheswasher or laundry tub 4 2 O Sink, bar or lavatory 2 1 I Sink, Clinic flushing 8 8 d Sink, kitchen 3 2 ,E , Vel_5 Sink, other (service) 3 1.5 21 Sink, wash fountain, circle spray 4 3 Urinal, flush valve, 1 GPF 5 2 Urinal, flush valve, >1 GPF 6 2 g Urinal, waterless 0 0 Water closet, tank or valve, 1.6 GPF 6 3 I Water closet, tank or valve, >1.6 GPF 8 4 GID King County Department of Natural Resources and Parks Wastewater Treatment Division Non - Residential Sewer Use Certification • To be completed for all new sewer connections, reconnections or change of use of existing connections. • This form does not apply to repairs or replacements of existing sewer connections within five years of disconnect. Please Print or Type Property Street Address City State ZIP // O t J c ti \ CDC' (fit Qom-'( Subdivision Name Subdiv. # Building Name c') I this` �L (if applicable) ( l. ) (010 Owner's Phone Number (with Area Code) Property Contact Phone Number (with Area Code) Owner's Mailing Address (xltxf,✓1 11 `�`d1 n Do 401 7 Lot # Block # 11 A. Fixture Units - Fixture Units x Number of Fixtures = Total Fixture Units Residential Customer Equivalent (RCE) 20 fixture units equal 1.0 RCE Total No. of Fixture Units = 20 Total Fixture Units' ) L RCE Print Name of Owner /Representative T � � yi 1058 (Rev. 9/07) White - Kinn County Yellow - Local Sewer Aoencv P nk - Sewer Customer Property Tax ID # Party to be Billed (if different from owner) City or Sewer District Date of Connection Side Sewer Permit # Please report any demolitions of pre - existing building on this property. Credit for a demolition may be given under some circumstances. Demolition of pre- existing building? ❑ Yes , No Was building on Sanitary Sewer? ❑ Yes ❑ No Was Sewer connected before 2/1/90? ❑ Yes ❑ No Sewer disconnect date: Type of building demolished? Request to apply demolition credit to multiple buildings? ❑ Yes ❑ No B. Other Wastewater Flow (in addition to Fixture Units identified in Section A) Type of Facility /Process: Estimated Wastewater Discharge: Gallons /days Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0 RCE Total Discharge (gal /day) __ 187 C. Total Residential Customer Equivalents: (add A & B) A B RCE Pursuant to King County Code 28.84, all sewer customers who establish a new service which uses metropolitan sewage facilities shall be subject to a capacity charge. The amount of the charge is established annually by the King County Council at a rate per month per residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. All future billings can be prepaid at a discounted amount. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at 206 - 684 -1740. I certify that the information given is correct. I understand that the capacity charge levied will be based on this information and any deviation will require resubmission of corrected data for determination of a revised capacity charge. Signature of Owner /Representative 1 - L L c Date - - G RCE . .� - FEB - 8 2008 Receipt No.: R08 - 00355 Initials: WER User ID: 1655 Payee: DEB SUBOTNIK ACCOUNT ITEM LIST: Description doc: Receiot -06 PLAN CHECK - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: D08 -077 Address: 555 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 02/08/2008 Applicant: GODIVA CHOCOLATIER Issue Date: TRANSACTION LIST: Type Method Description Amount Payment Check 1662 1,059.50 Account Code Current Pmts 000/345.830 1,059.50 Total: $1,059.50 • Payment Amount: $1,059.50 Payment Date: 02/08/2008 09:56 AM Balance: $1,634.50 n 8282 02/08 9710 TOTAL 1296.37 Printed: 02 -08 -2008 License Information License MARKECW066NU Licensee Name MARKET CONTRACTORS (WA) LTD Licensee Type CONSTRUCTION CONTRACTOR UBI 601018244 Ind. Ins. Account Id 51493700 Business Type CORPORATION Address 1 10250 NE MARX ST Address 2 City PORTLAND County OUT OF STATE State OR Zip 972201152 Phone 5032550977 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 8/31/1994 Expiration Date 9/13/2008 Suspend Date Separation Date Parent Company Previous License LWBOOC*133KK Next License Associated License Business Owner Information Name Role Effective Date Expiration Date BOONE, MICHAEL L 01/01/1980 BROWN, PATIRCIA J 01/01/1980 HUGHES, MICHELE W 01/01/1980 DILLON, LENNARD 01/01/1980 BODEN, JOHN T 01/01/1980 01/01/1980 WARMER, EDWARD S 01/01/1980 01/01/1980 Look Up a Contractor, Electric n or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond I Bond • Page 1 of 3 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= MARKECW066NU 04/16/2008 ABBREVIATIONS S SYMBOLS • AC ASPHALTIC CONCRETE/ ID INSIDE DIAMETER ACOUSTICAL CEILING INCL INCLUDE, INCLUDING ` SECTION SECTION `, R • #S 1 D C A-XXX / Receipt 1� - �.60-0 g - COD� E COMPLL City Qf Tukw a A -XXX ® - E � = 1 ��L::::: ' SE PA SEPARATE PERMIT SHEET NUMBER 1 2 3 4 5 6 7 8 9 1 r C.1 0 0 CI) LC) LO co C) Q 0 I. GO ISSUED ! REVISED DATE HEALTH DEPT SUBMITTAL 12.17.07 S8% DINNER REVIEW 01.03 08 HEALTH DEPT RVSNS 01.11.08 ISSUED OR PERMIT 0 .25.08 DATA SHEET DESCRIPTION AND REMARKS EXISTING LANDLORD GEN CONTR TENANT FURN INST FURN I INST FURN ONLY PRELIMINARY WORK: INSURANCE • • BARRICADES (IF REQUIRED) O • DEMOLITION AND RUBBISH REMOVAL OF REQUIRED) • • GRAVEL (IF REQUIRED) CONCRETE FILL OF REQUIRED) O • FULL CONCRETE SLAB (IF REQUIRED) • WADS AND CEILINGS: DEMISING WALL STUDS (IF REQUIRED) • DEMISING WALL GYPSUM BOARD(PATCH & REPAIR IF EXISTING' O • ROUGH CARPENTRY AND BLOCKING • • R -13 INSULATION IN STOCK ROOM PERIMETER WALLS AND R -19 ABOVE STOCK ROOM CEILING • • INTERIOR PARTITION • • GYPSUM BOARD CEILING IN SALES AREA AND TOILET ROOM • O ACOUSTICAL CEIUNG IN STOCK ROOM • • PAINTING • • FLOORINGS: MATCH MALI- FLOORING TO DOOR CLOSURE (IF REQUIRED" • • TILE FLOORING IN SALES AREA O • TILE FLOORING AND 6' TILE BASE IN STOCK ROOM AND TOILET ROOMS • • PAINTED WOOD WALLBASE IN SALES AREA • • STOREFRONT: STOREFRONT FRAMING • • STOREFRONT GLAZING • • PLUMBING: WATER METER (IF REQUIRED) • • UNDERSLAB PLUMBING WORK • • PLUMBING INCWDING MOP SINK & WATER HEATER • • HAND SINK (SALES AREA) • • SPRINKLER WIN • SPRINKLER HEADS (REFER TO MECHANICAL LEGEND) • • ELECTRICAL: ELECTRICAL METER (IF REQUIRED) • • UNDERSLAB ELECTRICAL WORK O • ELECTRICAL SERVICE • • O ELECTRICAL SWITCH GEAR • • • ELECTRICAL INSTALLATION • • UGHT FIXTURES (REFER TO ELECTRICAL LEGEND) ®. • TELEPHONE - CONDUIT IF REVD 0 FIRE ALARM UFE /SAFETY SYSTEM • • H.VAC.: H.VAC. • • SUPPLEMENTARY A/C IN STOCK ROOM (VENTROL) • • ROOFHOLES AS PER MALL CRITERIA O • REFRIGERATION START & CHECK -UP • INTERIOR FIXTURES: STORE FIXTURES • • STOCK ROOM SHELVING • • • CLOSING WORK: HOUSE CLEANING & FINAL CLEAN -UP • • 1 MUSIC SYSTEM PLAY NETWORK 8727 148TH AVENUE NE REDMOND, WA 98052 TEL: 888.567.7562 X.736 CONTACT: MICHELLE ROBLES EMAIL: mroblesl a- STOREFRONT SIGN /LETTERS: TRIANGLE SIGN & SERVICE 11 AZAR COURT BALTIMORE, MD 21227 TEL: 410- 247 -5300 FAX: 410 -247 -1944 CONTACT: STEPHEN ALTSHULER EMAIL: stephen .altshuler@trianglesign.com MECHANICAL REVIEW: BRINCO MECHANICAL 111 PLAINFIELD AVE. FLORAL PARK, NY 11001 CONTACT: CHAVONNE SHAW TEL 800.649.6804 STOREFRONT SYSTEM: CUSTOM STOREFRONTS 19935 W. 161ST STREET SUITE B OLATHE, KS 66062 TEL: 913.764.5042 FAX: 913.764.1845 CONTACT: JON R. ROBERTS EMAIL: jon customstorefronts.com WALL FIXTURES, FLOOR FIXTURES: PARISI INC. 305 PHEASANT RUN NEWTOWN, PA 18940 TEL: 215.968.6677 FAX: 215.968.3580 CONTACT: ANTHONY D'AMICO E MAIL adamico @parisi- royal.com ROLLING GRILLES METRO DOOR 1201 N. CHURC ST. BLDG. B - SUITE 303 HAZLETON, PA 18201 TEL: 800.669.3667 X.501 CONTACT: MIKE ONDECK 2 10 RESPONSIBILITY SCHEDULE MECHANICAL SUPPLIER: J.F. SEBASTIAN & SONS, INC. 11 WEST CENTRAL AVE. PAOU, PA 19301 -1363 TEL: 610.651.0808 FAX: 610.651.0815 CONTACT: ARLEEN BORUTA TELEPHONE: MNM GROUP 3235 SUNSET LANE HATBORO, PA 19040 CONTACT: ROB SCRUGGS TEL: 267.767.1112 EMAIL• rscruggs @themnmgroup.com FIRE EXTINGUISHERS: FIRE PRO CORP. 255 40TH STREET BROOKLYN, NY 11232 TEL: 800.567.5740 CONTACT: MIKE AGUILARO CUSTOM RESIN TILE; GRENEKER 3110 EAST 112TH STREET LOS ANGELES, CA 90023 TEL: 323.263.9000 FAX: 323.263.9543 CONTACT: SUSAN BATRES LIGHTING & ELECTRICAL E_QUIP.: CAPITAL LIGHTING 270 LOCUST STREET HARTFORD, CT 06141 TEL: 866.419.4455 FAX: 860.560.8315 CONTACT: WADE CLOW 05 VENDOR CONTACTS 3 FRAPPE MACHINE: BLENDTEC K -TEC INC. 1206 S. 1680 WEST OREM, UT 84058 TEL: 800.253.6383 X.307 CONTACT: ERIC KELLEMS WALL /FLOOR TILE & GROUT: VIRGINIA TILE 24404 INDOPLEX CIRCLE FARMINGTON HILLS, MI 48335 TEL: 734.762.2430 CONTACT: KELLY ROST UNDERCOUNTER FRIDGE: PARISI INC. 305 PHEASANT RUN NEWTOWN, PA 18940 TEL: 215.968.6677 FAX: 215.968.3580 CONTACT: ANTHONY D'AMICO EMAIL: adamico@parisi- royal.com LADY GODIVA MURAL: ANDRE'S IMAGING 2643 W. CHICAGO AVE. CHICAGO, IL 60622 TEL: 773.435.7646 FAX: 773.435.7610 CONTACT: GERARD STANISZEWSKI E MAIL: gerardms ©andresimaging.com NORDSTROM EXISTING GODIVA CHOCOLATIER KIOSK (TO BE REMOVED) 4 };AF.} Nt -. YFLPH rzrAlU (7 5T d:a^J t r RI 2! 9B Ft''JU. Ird! Efrie.F. Aig- q Irk W SElts Tf .: "F +d fir' ;firr' GODNA CHOCOLATIER RETAIL STORE SPACE #1020 LEVEL 1 OF 3 5 I,I U v ab� Zia 'F2Cfd �7�#F K 7Ta 6 4404E A r le Pt: TUFT 5. ALL REUSED MATERIAL & EQUIPMENT MUST BE REFURBISHED TO "LIKE NEW CONDITION. GODIVA CHOCOLATIER REMOTE STOCK ROOM rnacys U AP U 3. TENANT'S GENERAL CONTRACTOR SHALL CONFORM TO ALL REQUIREMENTS REGARDING CONSTRUCTION PROCEDURES, INSURANCE, ETC. AS SET FORTH BY THE LANDLORD. r' :14.,Nii AR L. { : „: 09 KEY PLAN 1. TENANT'S CONTRACTOR IS REQUIRED TO SCHEDULE A PRE - CONSTRUCTION MEETING WITH THE MALL OPERATIONS DIRECTOR TO REVIEW LANDLORD & MALL SPECIFIC REQUIREMENTS. 2. TENANT'S GENERAL CONTRACTOR SHALL VISIT THE PREMISES AND VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF CONSTRUCTION AND SHALL REPORT ALL DISCREPANCIES TO OWNER. 4. TENANT CONTRACTOR WILL REPAINT AND /OR REPAIR LANDLORD PROPERTY (NEUTRAL PIERS, BULKHEAD, ETC.) DAMAGED DURING TENANT IMPROVEMENT. ra. . w L. 'vo4 a n.!J.-•P IrP -I r „r atii r r g, v,b �r L.i 7. AFTER LANDLORD'S APPROVAL, ANY CHANGES OR MODIFICATIONS IN THE CONSTRUCTION DOCUMENT OR TENANT IMPROVEMENT MUST BE APPROVED BY LANDLORD'S TENANT COORDINATOR IN WRITING. 8. ALL ANGLED WALLS ARE © 45', 90', 135' U.O.N. 9. DOOR JAMBS ARE LOCATED 4" OFF ADJACENT WALL TYP. U.O.N. 10. ALL STOREFRONT GLAZING TO BE TEMPERED, WHERE APPLICABLE. 11. ALL WOOD BLOCKING TO BE FIRE RETARDANT TREATED WOOD. 12. ALL CEILING MATERIAL MUST HAVE CLASS "A" FIRE RATING. 13. SUPPORT WIRES FOR LAY -IN CEILING GRID, LIGHTS, HVAC EQUIPMENT, ETC. MUST NOT BE CONNECTED TO ANY OF LANDLORD'S ELECTRICAL AND PLUMBING AND FIRE PROTECTION PIPING, MECHANICAL EQUIPMENT OR ROOF DECK. 14. ALL SUPPORT WIRES MAY ONLY BE CONNECTED TO TOP CHORD OF JOIST AND /OR STRUCTURAL MEMBERS. 15. ALL MATERIALS USED IN THE CONSTRUCTION OF THIS SPACE MUST BE ASBESTOS FREE. 16. ANY PENETRATION OR MODIFICATIONS TO STRUCTURAL STEEL OR CONCRETE MUST BE COORDINATED AND APPROVED BY ON -SITE REPRESENTATIVE PRIOR TO START OF SUCH WORK. 17. SPRINKLER SHOP DRAWINGS MUST BE SUBMITTED TO THE LANDLORD'S INSURANCE UNDERWRITER FOR REVIEW AND APPROVAL BEFORE THE TENANT'S SYSTEM IS INSTALLED. 18. ALL DIMENSIONS THAT REFER TO A.F.F. ARE TO BE TAKEN FROM THE ACTUAL FINISHED FLOOR_ 19. TENANT'S GENERAL CONTRACTOR TO CHECK IN WITH MALL OPERATIONS MANAGER PRIOR TO WORK START. 04 GENERAL NOTES 7 6 r WQ U IL 4 8 I r.�n =r t�tarr 28. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE FOLLOWING: :;t4..SS 9 • eNeo CODt POPSO .7:3 1(.) 1.1-010-- riSIOVI 20. ANY PENETRATIONS OF OR MODIFICATIONS TO STRUCTURAL STEEL OR CONCRETE MUST BE COORDINATED WITH LANDLORD'S ON -SITE REPRESENTATIVE. 21. HAZARDOUS SUBSTANCES - IT IS THE RESPONSIBILITY OF THE TENANT AND THE TENANT'S CONTRACTOR(S), WHEN PREPARING FOR AND PROCEEDING WITH CONSTRUCTION IN THE PREMISES, TO COMPLY WITH ALL REQUIREMENTS OF ALL APPLICABLE LAWS CONCERNING HAZARDOUS SUBSTANCES. THE TENANT SHALL NOT PERMIT THE INSTALLATION OR USE OF ANY HAZARDOUS SUBSTANCES IN ANY COMPONENT OF THE PREMISES DURING IT'S TENANCY. 22. TENANT CONTRACTOR SHALL PERFORM FIRST-CLASS WORKMANSHIP. ACCEPTANCE CONTINGENT UPON LANDLORD APPROVAL 23. VERIFY ANY AND ALL DEMOLITION WORK REQUIRED BY THE LANDLORD W/ THE MALL OPERATIONS MANAGER, PRIOR TO BID 24. COORDINATE HOURS OF WORK, PARKING, LOADING AND TRASH REMOVAL WFFH MALL OPERATIONS MANAGER. 25. THIS CONTRACTOR WILL BE RESPONSIBLE FOR THE OVERALL SUPERVISION OF THE CONTRACT, COORDINATE ALL THE TRADES AND SUPPUES FOR LANDLORD AND /OR TENANT WORK WHETHER DIRECT SUPPLY OR OTHERWISE. 26. THIS CONTRACTOR TO ACT AS AGENT FOR "GODIVA CHOCOLATIER" AND WORK WITHIN THE GENERAL TERMS AND CONDITIONS APPLICABLE TO ALL TRADES AND LANDLORD'S TENANT CONSTRUCTION PROCEDURES. I) COMPLY WITH ALL APPUCABLE STATUTES AND ORDINANCES; REGULATIONS AND CODES; AND, THE REQUIREMENTS OF ANY GOVERNMENTAL REGULATORY BODY, AND DELIVER TO THE LANDLORD APPROPRIATE CERTIFICATES SHOWING COMPLIANCE WITH THE FOREGOING, IF REQUIRED. 27. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS NOT OBTAINED AND PROVIDED BY EXPEDITOR. EXPEDITOR IS RESPONSIBLE FOR OBTAINING BUILDING PERMIT AND HEALTH DEPARTMENT PERMIT. II) COORDINATE WITH TIME SCHEDULE OF THE LANDLORD, OR THEIR REPRESENTATIVE. III) COMPLY WITH THE GENERAL CHARACTER OF THE DEVELOPMENT. IV) COMPLY W/ THE STANDARDS OF THE NATIONAL BOARD OF FIRE UNDERWRITERS (NFBU); APPLICABLE RATING BUREAU; THE NATIONAL ELECTRIC CODE (NEC); THE AMERICAN SOCIETY OF HEATING & AIR CONDITIONING ENGINEERS (ASHAE); THE OCCUPATIONAL SAFETY & HEALTH ADMINISTRATION (OSHA); APPLICABLE STATE & BUILDING CODES; & THE REQUIREMENTS OF ALL PUBUC UTILITY COMPANIES SERVING THE DEVELOPMENT. V) ALL MATERIALS SHALL BE NEW AND BE SO SPECIFIED. VI) OBTAIN LANDLORD'S APPROVAL PRIOR TO MODIFYING ANY EXISTING UTILITY SYSTEMS. VII) THE LANDLORD MAY REQUIRE THAT CERTAIN WORK, INCLUDING : STRUCTURAL ALTERATIONS, SPRINKLER WORK, ROOF PENETRATIONS, ETC., BE PERFORMED BY THE LANDLORD'S CONTRACTOR AT THE TENANT'S EXPENSE. THE TENANT'S CONTRACTOR SHOULD VERIFY THE SPECIFIC REQUIREMENTS WITH THE DEVELOPER AT TIME OF BIDDING. h Lt T. NOPH H 10 -J 2 RECEIVED FEB -- 8 2008 PERMIT CENTER U: U EEEEED O crst ISSUED FOR PERMIT co 00 co (i) HEALTH DEPT RVSNS CD CV GO ISSUED / REVISED DATE HEALTH DEPT SUBMITTAL 12.17.07 98% OWNER REVIEW 01.03.08 01.11.08 01.25.08 RESPONSIBILIT SCHEDULE & KEY PLAN T-INI 8 A Y . : 01ksalWAWA 10 DEMOLITION FLOOR PLAN © KIOSK -. 1/4" = 1 ' -0 " - lagfikilAKW 'gc' a 7 ir' F a, -sad FA714a i;r ? ' EIFIEN5 rg�� a a, f I F _ 1 - J ....... ,.....^ SCALE: 1/4' = 1' STOWAGE Cr-DUN I ERa aivrHpr • NORTH _ I _ 0 2 4 8 04 DEMOLITION FLOOR PLAN @ REMOTE STORAGE 1/4" - 1' -0" GENERAL NOTES A. T.G.C. TO COORDINATE DEMOLITION W/ NEW WORK. REMOVE AND /OR PATCH AND REPAIR SURFACES & FINISHES AS REQUIRED TO PREPARE FOR NEW WORK. B. U.O.N. EXISTING UTILITY SERVICES & STUBS TO REMAIN AND BE REUSED. C. CHECK NEW MECHANICAL AND ELECTRICAL DRAWINGS PRIOR TO DEMOLITION WITH REGARD TO UTILIZING ANY EXISTING WIRING, LINES COMPONENTS ETC. D. PROVIDE TRASH CONTAINER AS REQUIRED AT LOCATION TO SUIT LANDLORD. REMOVE DEBRIS DAILY AND HAUL FROM THE SITE AT TIME TO SUIT LANDLORD. E. NOTIFY OWNER'S REP IMMEDIATELY OF ANY DISCREPANCIES OR UNFORESEEN ITEMS NOT SHOWN ON DRAWINGS. F. ALL REMOVED MATERIAL, NOT OTHERWISE DESIGNATED, AND ALL DEBRIS BECOMES THE PROPERTY OF THE CONTRACTOR, WHO SHALL REMOVE IT FROM THE SITE. G. G.C. SHALL NOT DEMOLISH ANY LOAD BEARING WALLS OR CONSTRUCTION THAT WILL COMPROMISE THE STRUCTURAL INTEGRITY OF THE EXISTING SPACE. G.C. TO NOTIFY THE OWNER'S REP IMMEDIATELY OF ANY STRUCTURAL CONDITIONS DURING CONSTRUCTION. H. EXISTING EQUIPMENT NOT BEING USED MUST BE COMPLETELY REMOVED / DISPOSED OF PROPERLY. NOTHING CAN BE ABANDONED ABOVE THE CEILING. SHEET NOTES . EXISTING 3 COMPARTMENT SINK TO BE REMOVED AND SALVAGED FOR USE AT NEW TENANT SPACE. CAP PLUMBING LINES AS REQUIRED. ADJACENT FINISHES TO BE PATCHED AND REPAIRED AS NEEDED. • EXISTING LAY —IN ACOUSTICAL CEILING TILES TO BE REMOVED. CLEAN EXISTING GRID AS NEEDED TO PROVIDE A ° LIKE —NEW CONDmON. . EXISTING KIOSK TO BE REMOVED COMPLETE. CAP ALL UTILITY LINES AS REQUIRED BY LANDLORD & GOVERNING CODE(S). ADJACENT FINISHES TO BE PATCHED AND REPAIRED AS NEEDED. Dbb.o17 REVIEWED FDR CODE COMP NCE APPROV FEB I (3 7ZR City CT FEB - 8 2008 PERMIT CENTER D -1.0 r -=, ISSUED / REVISED DATE HEALTH DEPT SUBMITTAL 98% OWNER REVIEW HEALTH DEPT RVSNS ISSUED FOR PERMIT v) tal 12.17.07 C .03.08 01.11.08 01.25.08 KIOSK DEMOLITION FLOOR PLAN F E D EXTEND INSULATION (WHERE OCCURS) 6 ABOVE UNDERSIDE OF CEILING EXTEND FINISH MATERIALS 6" ABOVE UNDERSIDE OF CEILING 0 ©0 STOCKROOM 102 © P - QT -1 B 13Q - '.0 SIM. RESTROOM W FRP /P -3 F QT -1 B BQ - SIM. D 3 - SALES AREA OPP. CPT -1 INDICATES DOOR NUMBER - REFER TO DOOR SCHEDULE ON SHEET A -3.0 INDICATES ROOM NUMBER INDICATES WALL TYPE LEASE UNE INDICATES WALL FINISH INDICATES FLOORING FINISH INDICATES WALL BASE FINISH FOR WALLS TO 10' -0 ": BRACE WITH 3625137 -33 AT 8' -0" MAX OC. ALTERNATE DIRECTION OF BRACES ALONG LENGTH OF WALL WHERE POSSIBLE. FOR WALLS TO 15' -0 ": BRACE WITH DOUBLED 3625137 -33 AT 8' -0" MAX OC. ALTERNATE DIRECTION OF BRACES ALONG LENGTH OF WALL. FASTEN DOUBLED STUDS TOGETHER WITH NO. 8 SCREWS AT 24" MAX OC. NTS + + A 4- + M ALTERNATE ATTACHMENT WHERE FULL HEIGHT WALL BOARDS NOT INDICATED AT ALL ACOUSTICAL PARTMONS (PARTrONS CONTAINING ACOUSTICAL INSULATION), APPLY A FILLET OF ACOUSTICAL SEALANT AT BOTTOM CORNER OF TRACK, EACH SIDE, PRIOR TO APPUCATION OF GYPSUM BOARD wypc r It:0kt C' L A, 9.v C t. e ieMA.I Wri4M fX fur: rats a4t woCity aot t W ke.. :^wam E 3e44.o RVA4 RCA/4"N or TTr-. A 4 FASTENERS: A r 2 3" X 3" X 3" ANGLE (20 GAGE MINIMUM), FASTENED TO TRACK AND BRACE PER DETAIL AT RIGHT 20 GAGE MINIMUM TRACK g (PER LA RR# o 25128) METAL STUDS, CUT 1/2 SHORT FOR 1/2" D EFLECTION FINISH MATERIALS VARY METAL STUDS z..... ...--- - (PER ICBO REPORT 4943P), MAXIMUM HEIGHT 20' -0" FINISH MATERIALS VARY A 15 BRACING CONNECTION DETAIL AT CIP CONCRETE FLOOR: PROVIDE HILTI X -DNI .145" DIA X 1" IE�MB R� (POWDER-ACTUATED A OC 5 PER STAGGERED FOR 1 LAYER GYPSUM BOARD EACH SIDE, 16" MAXIMUM OC STAGGERED FOR 2 LAYERS GYPSUM BOARD EACH SIDE 05 DETAIL © FLOOR CONNECTION 3 " = 1' -0 LINDF.R.S! 7E or DEI - Awrre " DLO 'TED ' rRAc 4( OR E0:p f y r PEN a.1 -IEDL E CELV'!-,2 9y TENANT :I % IE = Ot`C.r;P.i) ..8` r LLo sTUOS 0 tri.' -ry- E (CTl s � thltS . F +l TTt I I r"tf..(4)1 N AP; TAKEN Et70 8 UCS SPECIFICATInti FOR IC INICA O EaSEMET *. REg'ER TO jcUMUNIVflO? FOR C C P T E Asa - met.Y RAE'. JEIEN IS AND ALLOWABLt (PITONS. CYMV 90:T1n 5/8" "- a< 4 " AT7AOHED r; IEE1, 'STUDS ,v41 FLOOR T) C ILG TRACK WTH III 4 , T 54:13F S! AC C: 6 IN. EE E:: )- EC, R;: MD T^ t CC N ?H% F w: m ; . 4 ?. .;04NT5 MENIU W.R "'A:.t ?' AND , TAB- .REG . ..._��zc.,,.s.._....I._.a...s.. r� hn .1 - zAMSE T A. RECIOIEs %U STEEL. TR -CI( FtacP 'TIFF$H ST"RIU T;,'RAL DRAWN GS PAINTABLE FIRES'W SE.A.:.ANT ".I;( TH .7}.X aL aYP € Ei AND iNSTAu,_: BY TENAN7 3 04 WALL TYPE © TENANT DEMISING WALLS NTS WALL TYPE SCHEDULE STRUCTURE IAI } SHEET NOTES CONTRACTOR'S OPTION: TERMINATE WALL 6" MIN. ABOVE CEILING OR EXTEND TO DECK CEIUNG (WHERE OCCURS) DRAFT STOP AS REQ'D BY CODE WHEN APPLICABLE, REFER TO PLAN FOR FINISH LEASE UNE WALLS PARTITION CONFIGURATION: PARTIAL - HEIGHT FINISH MATERIALS BOTH SIDES OO11 4 ler STRUCTURE CEILING (WHERE OCCURS EXTEND INSULATION (WHERE OCCURS) 6" ABOVE UNDERSIDE OF CEIUNG (1) LAYER 5/8" TYPE X GYP. BD. 1. LEASE LINE DENOTES LIMITS OF WORK. 2. LANDLORD'S EXISTING DEMISING WALL (STUDS). EXISTING NEUTRAL PIER. REFER TO LL'S DOCUMENTATIONS FOR SPECIAL RQMNTS AT PIERS. T.G.C. TO PROVIDE AND INSTALL 5/8" TYPE "X" GYP. BD. AT TENANT SIDE OF EXISTING DEMISING WALL & MALL BULKHEAD /SOFFIT. FINISH PER LL'S DETAIL 4 THIS SHEET. EXISTING 3 COMPARTMENT SINK TO BE RELOCATED - REFER TO PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION. 6. NEW ELECTRICAL EQUIPMENT. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 7. NEW STOREFRONT SYSTEM - SUPPLIED BY TENANT AND INSTALLED BY T.G.C. 8. RELOCATED 3 COMPARTMENT SINK - REFER TO PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION. 9. EXISTING COLUMN TO REMAIN. 10. 5' -0" TURNING RADIUS FOR ADA COMPLIANCE. 5 DRAFT STOP AS REQ'D BY CODE IBI PARTITION CONFIGURATION: PARTIAL- HEIGHT FINISH MATERIALS ONE SIDE NO FINISH MATERIAL ONE SIDE 11. NEW PLUMBING FIXTURE IN COUNTERTOP - SUPPLIED BY TENANT & INSTALLED BY T.G.C. - REFER TO FIXTURE & PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION. 12. T.G.G. TO PROVIDE WATERPROOFING PER LANDLORD'S REQUIREMENTS UNDER FLOOR FINISH - EXTEND BEHIND NEW BASE MATERIAL AT PERIMETER WALLS TO 6" A.F.F. 13. LOCATION OF FIRE EXTINGUISHER 14. EXISTING MOP SINK TO REMAIN. 15. INSTALL PT -1 TILE WITH 1/2 OFFSET PATTERN IN ORIENTATION SHOWN. 16. NEW MOP SINK - SUPPLIED BY OWNER AND INSTALLED BY T.G.C. 17. NEW WATER HEATER ABOVE MOP SINK - REFER TO PLUMBING DRAWINGS FOR MORE INFORMATION. 18. PROVIDE R-19 BATT INSULATION IN LL'S DEMISING WALLS. 19. EXISTING ELECTRICAL PANEL TO REMAIN. CONTRACTOR'S OPTION: TERMINATE WALL 6" MIN. ABOVE CEILING OR EXTEND TO DECK 08 DETAIL @ COL. ENCLOSURE 1 1 /2 " = i ' -O n 10' -6" EXISTING REMOTE STOCK ROOM C 104 W F B P -3 EXST EXST STRUCTURE CEILING (WHERE OCCURS EXTEND FINISH MATERIALS (& INSULATION WHERE OCCURS) 6" ABOVE UNDERSIDE OF CEILING WALL TILE OVER (1) LAYER 1/2" DUROCK ‚ PARTITION CONFIGURATION: PARTIAL- HEIGHT FINISH MATERIALS ONE SIDE NO FINISH MATERIAL ONE SIDE 5/8" GYP. BD. 1 5/8" Mm. STUDS 6 CONTRACTOR'S OPTION: TERMINATE WALL 6" MIN. ABOVE CEILING OR EXTEND TO DECK f i DRAFT STOP AS REQ'D BY CODE EXISTING DEMISING WALL WHERE OCCURS (SINGLE LAYER 5/8" TYPE X GWB WHEN STAND A STAND ALONE PARTITION) L N 03 FLOOR PLAN @ REMOTE STOCK RM 1/4- = 1' -0" 1 STRUCTURE CEILING (WHERE OCCURS) EXTEND INSULATION (WHERE OCCURS) 6" ABOVE UNDERSIDE OF CEILING EXTEND FINISH MATERIALS 6" ABOVE UNDERSIDE OF CEILING (1) LAYER 5/8" TYPE X GYP. BD. PER SIDE. D PARTITION CONFIGURATION: FULL - HEIGHT FINISH MATERIALS BOTH SIDES 1 RATED WALL - MI 465 20. MANUAL SLIDING GLASS DOOR -DOOR EXTENDS BEYOND JAMBS WHEN IN CLOSED POSITION & EXTENDS LENGTH OF ADJACENT GLAZING WHEN IN OPEN POSITION. 21. C.C. TO EXTEND EXISTING MALL TILE FROM EXISTING MALL TILE AT LEASE LINE TO GODIVA'S ENTIRE STOREFRONT BASE. TILE TO MATCH EXISTING MALL TILE IN TYPE, COLOR, SIZE, THICKNESS, GROUT COLOR AND INSTALLATION DIRECTION. NO THRESHOLD, REDUCER STRIP OR OTHER WIDE TRANSfTION DEVICES AT INTERSECTION OF GODIVA'S FLOORING & MALL TILE. WHEN EXTENDING MALL TILE TO GODIVA'S STOREFONT BASE, TILES MUST BE FULL TILE. IF THE MALL TILE IS CUTE, IT MUST BE REMOVED AND REPLACED WITH FULL TILE. 22. NEW HAND SINK -- SUPPLIED BY TENANT & INSTALLED BY T.G.C. - REFER TO FIXTURE & PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION. 7 Ci Calk 114 %0 �s CEO mot 1 s s 100 male Imo CEO CEO mot woo WHEN APPLICABLE, REFER TO PLAN FOR FINISH LEASE LINE WALLS 1 /4" - 1 -0" INSULATION IF NOTED. TYPE PER BELOW GWB OR SUBSTRATE SHEATHING n inn T I 4 1 8 2 1/2" METAL STUDS 3 5/8" METAL STUDS 29' -9" VIF 01 FLOOR PLAN 20 GA. METAL STUDS *16" O.C. SIZE PER BELOW 1 5/8" METAL STUDS 4" METAL STUDS 6" METAL STUDS NO INSULATION SOUND ATTENUATION BAIT I t I R-13 OR R -19 INSULATION R -13 © TYPE 3 MTL STUDS; R -19 @ TYPE 6 MTL STUDS 23. REPAINT EXISTING WALLS & CLEAN & REPAIR FLOOR /BASE TILES AS NEEDED. VERIFY BATT INSULATION INSTALLED ABOVE CEILING TILES. INSTALL R -19 BATT ABOVE ANY CEIUNG AREA WITHOUT EXISTING. 9 GENERAL NOTES A. GENERAL CONTRACTOR TO LAY OUT ALL PARTITIONS, STOREFRONT & FIXTURES, ALL AS SHOWN ON THEIR RESPECTIVE DRAWINGS & VERIFY DIMENSIONS PRIOR TO STARTING WORK OR ORDERING ANY COMPONENTS. B. EXISTING FLOOR SLAB TO BE CORED OR DRILLED TO ALLOW FOR UNDERGROUND ELECTRICAL CONNECTION TO FREE STANDING FLOOR FIXTURE; FILL IN FLOOR SLAB TO TAKE SPECIFIED FLOOR FINISHES AS PER MANUFACTURER'S RECOMMENDATIONS. C. EXPANSION JOINTS: SHOULD ANY EXPANSION JOINTS OCCUR OR BE REQUIRED ON FLOOR, DEMISING WALLS AND CEILING, TENANT CONTRACTOR SHALL BE RESPONSIBLE FOR THE CONSTRUCTION OF ALL MATERIALS AND FINISHES AFFECTED BY SUCH JOINTS IN A MANNER CONSISTENT WITH LANDLORD CRITERIA AND BUILDING CODE. D. ALL MATERIALS AND WORK TO MEET ALL LOCAL CODES AND ORDINANCES. E. PROVIDE BLOCKING FOR ALL WALL SUPPORTED FIXTURES WITHIN WALLS AND ABOVE CEILING LINE - WOOD FOR BLOCKING TO BE FIRE RETARDANT. F. PROVIDE FRP FINISH AT ALL WALLS BEHIND & ADJACENT TO PLUMBING FIXTURES, TYP U.O.N. G. CONTRACTOR MUST VERIFY ALL JOB DIMENSIONS, DRAWINGS, DETAILS & SPECIFICATIONS AND REPORT ANY DISCREPANCIES TO OWNER'S REPRESENTATIVE BEFORE PROCEEDING WITH WORK. ARCHITECT WILL NOT BE LIABLE FOR ANY ERRORS & OMISSIONS NOT REPORTED BY GC. H. DO NOT SCALE DRAWINGS. I. SPRINKLERS SHALL BE PROVIDED FOR THIS BUILDING. A SEPARATE SPRINKLER PERMIT SHALL BE REQUIRED FOR ANY SPRINKLER MODIFICATION. LANDLORD NOTES 1. AT RESTROOMS: INSTALL CERAMIC TILE FLOORING OVER WATERPROOFING MEMBRANE WHICH IS TO RUN UP WALLS MINIMUM OF 4 " . TENANTS ARE TO INSTALL A LANDLORD'S APPROVED LATEX RUBBER WATERPROOFING MATERIAL UNDER THE FLOOR FINISH. THE MEMBRANE SHALL BE MANUFACTURER'S 2 PART FORMULA CONSISTING OF LIQUID LATEX RUBBER AND POWDER FOR TROWEL APPUCATION WITH GLASS FIVER FABRIC REINFORCEMENT (LATICRETE 9235 OR SUMMITVILLE S -9000) INSTALL A WATER TIGHT DOOR THRESHOLD. 2. TENANT'S CONTRACTOR TO VERIFY LOCATION AND GET APPROVAL AND REQUIREMENTS FOR ALL TRENCHING WITH WESFIELD'S ON SITE TENANT COORDINATOR BEFORE PROCEEDING WITH WORK. 3. CUT AND CAP ALL PIPING THAT WILL BE UNUSED TO FLOOR END OF LINE. 4. ALL SLAB ON GRADE CONCRETE TRENCH POUR -BACKS SHALL CONSIST OF A MIN 6" 3000PSI CONCRETE OVER 15 MIL VISQUEEN OVER 4" CAPILLARY BREAK GRAVEL OVER COMPACTED FILL. STEEL REINFORCEMENT SHALL CONSIST OF 24 #4 REBAR DOWELS SET IN PLACE WITH HIGH STRENGTH EPDXY AT A 5" EMBED, SPACED 18 OC EACH WAY. SYMBOLS LEGEND seg. 110.170 IPc Joan MAW �pN1ML .11160 131144 KC aquatic ►wW 4 w a . FEB -8 2008 PERMIT CENTER SCALE: 1/4" = 1' 8'--2" VIE 10 NORTH t FLOOR PLAN A -1.0 co C op Id EL CT5 CD VO Co ISSUED / REVISED DATE HEALTH DEPT SUBMITTAL 12.17.07 98% OWNER REVIEW 01.03.08 HEALTH DEPT RVSNS 01.11.08 ISSUED FOR PERMIT 01.25.08 1 DOOR TYPES 3' -0" DOOR A SALES SIDE t 2 A BACK SIDE ca w 3 REFER TO PLAN SLIDING GLASS DOOR OPENING 4 1 r j / / I /it 5 3' -0" DOOR C DOOR SCHEDULE & SPECIFICATIONS DOOR MARK 101A 101B 102 103 104 SIZE 6 7 4' -8 "x10' -0 "(PAIR) -7' -0" OPEN 4' -8 "x 10' -0 "(PAIR) -7' -0" OPEN 3' -0" X 6' -8" X 1 3/4" 3' -0" X 6' -8" X 1 3/4" 3'--0" X 6' -8" X 1 3/4" DOOR DATA MATERIAL ALUM, GLASS ALUM, GLASS WOOD WOOD TYPE B FINISH MANUF MANUF ST -1 P -3 P -3 SET #1 EXTERIOR / STOCKROOM DOOR: 3' -0" X 6' -8" X 1 3/4" INSULATED STEEL FRAME: HOLLOW METAL KD INSULATED LEVER SET: SCHLAGE AL8OBD- SAT -626 STOREROOM LOCK, 2 3/4" BACKSET, 11 -096 SPRINGLATCH, 10 -001 STRIKE (PRPARED FOR "BEST" CORE) HINGES: MCKINNEY 4 1/2" X 4 1/2" T2714- NRP - US26D, 1 1/2" SET CLOSER: NORTON 7500 PARALLEL ARM STOCK ROOM SIDE STOP: WALL BUMPER US26D FINISH SILENCERS: 3 NEOPRENE SEAL: PEMKO 303APK HEAD & JAMBS THRESHOLD: PEMKO 2005AT SET #2 INTERIOR CORRIDOR / STOCKROOM DOOR: 3' -O" X 6' -8" X 1 3/4" INSULATED STEEL FRAME: HOLLOW METAL KD INSULATED LEVER SET: SCHLAGE AL8OBD- SAT -626 STOREROOM LOCK, 2 3/4" BACKSET, 11 -096 SPRINGLATCH, 10 -001 STRIKE (PRPARED FOR "BEST" CORE) HINGES: MCKINNEY 4 1/2" X 4 1/2" T2714-NRP-US26D, 1 1/2" SET CLOSER: NORTON 7500 PARALLEL ARM STOCK ROOM SIDE STOP: WALL BUMPER US26D FINISH SILENCERS: 3 NEOPRENE SEAL: PEMKO PK33W HEAD & JAMBS BOTTOM: PEMKO 315BN (ON STOCKROOM SIDE) MATERIAL ALUM ALUM HM HM FRAME TYPES TYPE 2" DOOR SIZE* 2" i HOLLOW METAL DOOR FRAME FRAME DATA IV Q JAMB J1 J1 8 HEAD H1 H1 FINISH MANUF MANUF P -2/P -3 P -3 LABEL N/A N/A N/A N/A * HARDWARE SET NO. MANUF MANUF 4 SET #3 SALES / STOCKROOM DOOR: 3' -0" X 6' -8" X 1 3/4" SOLID CORE QUARTERED ASH FRAME: HOLLOW METAL KD LEVER SET: SCHLAGE AL10S -JUP -613 PASSAGE LATCH, 2 3/4" BACKSET, 11 -116 SPRINGLATCH, 10 -025 STRIKE HINGES: MCKINNEY 4 1/2" X 4 1/2" 1522- HT -US10B STANDARD WEIGHT SPRING HINGE SET CLOSER: NORTON 7500 PARALLEL ARM STOCK ROOM SIDE STOP: WALL BUMPER US10B FINISH SILENCERS: 3 NEOPRENE SEAL: PEMKO PK33W HEAD & JAMBS BOTTOM: PEMKO 315BN (ON STOCKROOM SIDE) SET #4 TOILET / STOCKROOM DOOR: 3' ---0" X 6' -8" X 1 3/4" SOLID CORE WOOD FRAME: HOLLOW METAL KD LEVER SET: SCHLAGE AL40S -JUP -613 PRIVACY LATCH, 2 3/4" BACKSET, 11 -116 SPRINGLATCH, 10 -025 STRIKE HINGES: MCKINNEY 4 1/2" X 4 1/2" 1522- HT -US10B STANDARD WEIGHT SPRING HINGE SET STOP: WALL BUMPER US10B FINISH SILENCERS: 3 NEOPRENE PREP ROOM KEY SIDE N EXTR. EXTR. SALES 1 1 9 3" = 1' -0" ALL HARDWARE TO BE PROVIDED AND INSTALLED BY T.G.C. NOTES MANUAL SLIDING GLASS DOOR -DOOR EXTENDS BEYOND JAMBS WHEN IN CLOSED POSITION & EXTENDS LENGTH OF ADJACENT GLAZING WHEN IN OPEN POSITION SALES TO STOCKROOM - FURNISHED BY PARISI RESTROOM PROVIDE NEW FINISH AND HARDWARE AS INDICATED 1. DOOR HARDWARE, HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING, OR TWISTING OF THE WRIST TO OPERATE. LEVER - OPERATED MECHANISMS, PUSH-- -TYPE MECHANISMS AND U- SHAPED HANDLES ARE ACCEPTABLE DESIGNS. HARDWARE REQUIRED FOR ACCESSIBLE DOOR PASSAGE SHALL BE MOUNTED NO LOWER THAN 30 INCHES OR NO HIGHER THAN 48 INCHES (1220MM) ABOVE THE FINISHED FLOOR. 2. DOOR CLOSERS. IF DOOR HAS A CLOSER, THEN THE SWEEP PERIOD OF THE CLOSER SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 70 DEGREES, THE DOOR WILL TAKE AT LEAST 3 SECONDS TO MOVE TO A POINT 3 INCHES (75MM) FROM THE LATCH, MEASURED TO THE LEADING EDGE OF THE DOOR. 3. DOOR OPENING FORCE. THE MAXIMUM FORCE APPLIED AT RIGHT ANGLES TO A HINGED DOOR FOR PUSHING OR PULLING OPEN A DOOR SHALL BE AS FOLLOWS: INTERIOR HINGED DOORS: 5 LBF (22.2N) 4 7/8" 4 7/8" 5 7/8" 06 JAMB DETAILS DOb•61/ SEE PARTITION TYPE METAL FRAME R FOR PAINTED � �� SEE DOOR TYF ECODE COMP !, APPROVED FEB 1 . ? �B SEE PARTITION TYPE 2" CONT. CAULK (•) METAL FRAME PAINTED v CONT. CAULK (W.) H1 J1 SEE DOOR TYPE 10 • City Of BUILDING DVIS.121_ RECLffiS FEB - 8 2008 PERMIT CENTEF, ISA • ISSUED / REVISED DATE HEALTH DEPT SUBMITTAL 12.17.07 98% OWNER REVIEW 01.03.08 HEALTH DEPT RVSNS 01.11.08 ISSUED FOR PERMIT 01.25.08 DOOR SCHEDULE & DETAILS A -1.1 \ n i / \ / / P -3 / \ 1 DOOR TYPES 3' -0" DOOR A SALES SIDE t 2 A BACK SIDE ca w 3 REFER TO PLAN SLIDING GLASS DOOR OPENING 4 1 r j / / I /it 5 3' -0" DOOR C DOOR SCHEDULE & SPECIFICATIONS DOOR MARK 101A 101B 102 103 104 SIZE 6 7 4' -8 "x10' -0 "(PAIR) -7' -0" OPEN 4' -8 "x 10' -0 "(PAIR) -7' -0" OPEN 3' -0" X 6' -8" X 1 3/4" 3' -0" X 6' -8" X 1 3/4" 3'--0" X 6' -8" X 1 3/4" DOOR DATA MATERIAL ALUM, GLASS ALUM, GLASS WOOD WOOD TYPE B FINISH MANUF MANUF ST -1 P -3 P -3 SET #1 EXTERIOR / STOCKROOM DOOR: 3' -0" X 6' -8" X 1 3/4" INSULATED STEEL FRAME: HOLLOW METAL KD INSULATED LEVER SET: SCHLAGE AL8OBD- SAT -626 STOREROOM LOCK, 2 3/4" BACKSET, 11 -096 SPRINGLATCH, 10 -001 STRIKE (PRPARED FOR "BEST" CORE) HINGES: MCKINNEY 4 1/2" X 4 1/2" T2714- NRP - US26D, 1 1/2" SET CLOSER: NORTON 7500 PARALLEL ARM STOCK ROOM SIDE STOP: WALL BUMPER US26D FINISH SILENCERS: 3 NEOPRENE SEAL: PEMKO 303APK HEAD & JAMBS THRESHOLD: PEMKO 2005AT SET #2 INTERIOR CORRIDOR / STOCKROOM DOOR: 3' -O" X 6' -8" X 1 3/4" INSULATED STEEL FRAME: HOLLOW METAL KD INSULATED LEVER SET: SCHLAGE AL8OBD- SAT -626 STOREROOM LOCK, 2 3/4" BACKSET, 11 -096 SPRINGLATCH, 10 -001 STRIKE (PRPARED FOR "BEST" CORE) HINGES: MCKINNEY 4 1/2" X 4 1/2" T2714-NRP-US26D, 1 1/2" SET CLOSER: NORTON 7500 PARALLEL ARM STOCK ROOM SIDE STOP: WALL BUMPER US26D FINISH SILENCERS: 3 NEOPRENE SEAL: PEMKO PK33W HEAD & JAMBS BOTTOM: PEMKO 315BN (ON STOCKROOM SIDE) MATERIAL ALUM ALUM HM HM FRAME TYPES TYPE 2" DOOR SIZE* 2" i HOLLOW METAL DOOR FRAME FRAME DATA IV Q JAMB J1 J1 8 HEAD H1 H1 FINISH MANUF MANUF P -2/P -3 P -3 LABEL N/A N/A N/A N/A * HARDWARE SET NO. MANUF MANUF 4 SET #3 SALES / STOCKROOM DOOR: 3' -0" X 6' -8" X 1 3/4" SOLID CORE QUARTERED ASH FRAME: HOLLOW METAL KD LEVER SET: SCHLAGE AL10S -JUP -613 PASSAGE LATCH, 2 3/4" BACKSET, 11 -116 SPRINGLATCH, 10 -025 STRIKE HINGES: MCKINNEY 4 1/2" X 4 1/2" 1522- HT -US10B STANDARD WEIGHT SPRING HINGE SET CLOSER: NORTON 7500 PARALLEL ARM STOCK ROOM SIDE STOP: WALL BUMPER US10B FINISH SILENCERS: 3 NEOPRENE SEAL: PEMKO PK33W HEAD & JAMBS BOTTOM: PEMKO 315BN (ON STOCKROOM SIDE) SET #4 TOILET / STOCKROOM DOOR: 3' ---0" X 6' -8" X 1 3/4" SOLID CORE WOOD FRAME: HOLLOW METAL KD LEVER SET: SCHLAGE AL40S -JUP -613 PRIVACY LATCH, 2 3/4" BACKSET, 11 -116 SPRINGLATCH, 10 -025 STRIKE HINGES: MCKINNEY 4 1/2" X 4 1/2" 1522- HT -US10B STANDARD WEIGHT SPRING HINGE SET STOP: WALL BUMPER US10B FINISH SILENCERS: 3 NEOPRENE PREP ROOM KEY SIDE N EXTR. EXTR. SALES 1 1 9 3" = 1' -0" ALL HARDWARE TO BE PROVIDED AND INSTALLED BY T.G.C. NOTES MANUAL SLIDING GLASS DOOR -DOOR EXTENDS BEYOND JAMBS WHEN IN CLOSED POSITION & EXTENDS LENGTH OF ADJACENT GLAZING WHEN IN OPEN POSITION SALES TO STOCKROOM - FURNISHED BY PARISI RESTROOM PROVIDE NEW FINISH AND HARDWARE AS INDICATED 1. DOOR HARDWARE, HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING, OR TWISTING OF THE WRIST TO OPERATE. LEVER - OPERATED MECHANISMS, PUSH-- -TYPE MECHANISMS AND U- SHAPED HANDLES ARE ACCEPTABLE DESIGNS. HARDWARE REQUIRED FOR ACCESSIBLE DOOR PASSAGE SHALL BE MOUNTED NO LOWER THAN 30 INCHES OR NO HIGHER THAN 48 INCHES (1220MM) ABOVE THE FINISHED FLOOR. 2. DOOR CLOSERS. IF DOOR HAS A CLOSER, THEN THE SWEEP PERIOD OF THE CLOSER SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 70 DEGREES, THE DOOR WILL TAKE AT LEAST 3 SECONDS TO MOVE TO A POINT 3 INCHES (75MM) FROM THE LATCH, MEASURED TO THE LEADING EDGE OF THE DOOR. 3. DOOR OPENING FORCE. THE MAXIMUM FORCE APPLIED AT RIGHT ANGLES TO A HINGED DOOR FOR PUSHING OR PULLING OPEN A DOOR SHALL BE AS FOLLOWS: INTERIOR HINGED DOORS: 5 LBF (22.2N) 4 7/8" 4 7/8" 5 7/8" 06 JAMB DETAILS DOb•61/ SEE PARTITION TYPE METAL FRAME R FOR PAINTED � �� SEE DOOR TYF ECODE COMP !, APPROVED FEB 1 . ? �B SEE PARTITION TYPE 2" CONT. CAULK (•) METAL FRAME PAINTED v CONT. CAULK (W.) H1 J1 SEE DOOR TYPE 10 • City Of BUILDING DVIS.121_ RECLffiS FEB - 8 2008 PERMIT CENTEF, ISA • ISSUED / REVISED DATE HEALTH DEPT SUBMITTAL 12.17.07 98% OWNER REVIEW 01.03.08 HEALTH DEPT RVSNS 01.11.08 ISSUED FOR PERMIT 01.25.08 DOOR SCHEDULE & DETAILS A -1.1 MOUNTING HEIGHTS DIMENSION MOUNTING HEIGHT (INCHES) TOILET CENTERING FROM WALL 18 TOILET SEAT HEIGHT J DIMENSION TO TOP OF SEAT 17 -19 GRAB BAR HEIGHT (SIDE) 33 TOILET PAPER IN FRONT OF TOILET 12 MAX. NAPKIN DISPOSAL IN FRONT OF TOILET 12 MAX. DISPENSER OR MIRROR HEIGHT 40 MAX. LAVATORY / SINK TOP HEIGHT 34 MAX. LAVATORY / SINK KNEE CLEARANCE 29 MAX. URINAL LIP HEIGHT 17 MAX. URINAL FLUSH HANDLE HEIGHT 44 MAX. DRINKING FOUNTAIN BUBBLER HEIGHT 36 MAX. DRINKING FOUNTAIN KNEE CLEARANCE 27 MAX. RAMP / STAIR HANDRAIL HEIGHT ] 34 -38 6 7 8 9 10 RESTROOM NOTES TOILET ROOM FIXTURES AND ACCESSORIES 1. THE HEIGHT OF ACCESSIBLE WATER CLOSETS SHALL BE A MINIMUM OF 17 INCHES AND A MAXIMUM OF 19 INCHES MEASURED TO THE TOP OF THE TOILET SEAT. 2. TOILET F i I U CONTROLS SHALL BE OPERABLE WITH ONE HAND, AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF .5 FOR THE FLUSH VALVES SHALL BE MOUNTED ON THE WIDE SIDE OF THE TOILET AREAS, NO MORE THAN 44 INCHES ABOVE THE OR. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS. 3. A CLEAR FLOOR SPACE 30 INCHES WIDE X 48 INCHES LONG SHALL BE PROVIDED IN FRONT OF A LAVATORY TO ALLOW A FORWARD SUCH CLEAR FLOOR SPACE SHALL ADJOIN OR OVERLAP AN ACCESSIBLE ROUTE AND SHALL EXTEND INTO KNEE AND TOE SPACE UNDERNEATH THE LAVATORY. 4. LAVATORIES SHALL BE MOUNTED WITH A CLEARANCE OF AT LEAST 29 INCHES FROM THE FLOOR TO THE BOTTOM OF THE APRON WfFH THE KNEE CLEARANCE UNDER THE FRONT UP EXTENDING A MINIMUM OF 30 INCHES IN WIDTH WITH 8 INCHES MINIMUM DEPTH AT THE TOP. TOE LANCE SHALL BE THE SAME WIDTH AND SHALL BE A MINIMUM OF 9 INCHES HIGH FROM THE FLOOR AND A MINIMUM OF 17 INCHES EP FROM THE FRONT OF THE LAVATORY. 5. A PROJECTION OF A LAVATORY BOWL INTO THE 8 INCH CLEAR SPACE, THEREBY REDUCING THE CLEAR HEIGHT BELOW THE LAVATORY TO NO LESS THAN 27 INCHES AT 8 INCHES BACK FROM THE APRON, MEETS THE REQUIREMENT FOR PROVIDING KNEE CLEARANCE. 6. HOT WATER AND DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE COVERED. THERE SHALL BE NO SHARP ABRASIVE SURFACES UNDER LAVATORIES. 7. FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 LBF. LEVER - OPERATED, PUSH -TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGNS. SELF - CLOSING VALVES ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS. 8. MIRRORS SHALL BE MOUNTED W/ THE BOTTOM EDGE NOT MORE THAN 40 INCHES FROM THE FLOOR. 9. LOCATE TOILET TISSUE DISPENSERS ON THE WALL W /IN 12" OF THE FRONT EDGE OF THE TOILET SEAT. 10. LOCATE TOWEL, SANITARY NAPKIN WITH ALL OPERABLE PARTS NOT MORE THAN 40 INCHES FROM THE FLOOR. GRAB BARS 1. GRAB BARS, FASTENERS AND MOUNTING DEVICES SHALL BE DESIGNED FOR 250LB PER LINEAR FT. LOAD. 2. GRAB BARS SHALL BE LOCATED ON EACH SIDE, OR ONE SIDE AND THE BACK OF THE PHYSICALLY DISABLED TOILET STALL OR COMPARTMENT AND SHALL BE SECURELY ATTACHED 33 INCHES ABOVE AND PARALLEL TO THE FLOOR 3. GRAB BARS AT THE SIDE SHALL BE AT LEAST 42 INCHES LONG WITH THE FRONT END 4. POSITIONED 24 INCHES IN FRONT OF THE WATER CLOSET STOOL, AND GRAB BARS AT THE BACK SHALL BE NOT LESS THAN 36 INCHES LONG. 5. THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF A GRAB BAR SHALL BE 1 -1/4 INCHES TO 1 -1/2 INCHES OR THE SHAPE SHALL PROVIDE AN EQUIVALENT GRIPPING SURFACE. 6. IF THE GRAB BARS ARE MOUNTED ADJACENT TO A WALL, THE SPACE BETWEEN THE WALL AND THE GRAB BARS SHALL 1 -1/2 INCHES. 7. A GRAB BAR AND ANY WALL OR OTHER SURFACE ADJACENT TO SHALL BE FREE OF ANY SHARP OR ABRASIVE ELEMENTS. 8. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS. 9. EDGES SHALL HAVE A MINIMUM RADIUS OF 1/8 INCH. SYMBOL KEY INDICATES FINISH MATERIAL, REFER TO FINISH SCHEDULE ON SHEET A -1.1 <EQ -z?' INDICATES TENANT FIXTURE REFER TO FIXTURE SCHEDULE <AF N. ON SHEET F -1.0 FOR ADDITIONAL INFORMATION 05 ENLARGED RESTROOM PLAN 1/2" = 1' -0" MOUNTING HEIGHTS I ACCESSIBILTIY I <AF- 23>- - 12" ID 39"-41" WALL 54" MIN. 28" MIN. TO EDGE OF WATER CLOSET 30 ° x48" CLEAR FLOOR SPACE 60" DIA. CLEAR FLOOR SPACE 1' -6" 1 /2" = 1' -0" 42 MIN. 7 " -9" I m i - 4 A \ \ 36" MIN. �ry 32" MIN. I. 18" • CLEAR MIN.' PER SECTION 4.22 ADA 1 C, SIDE VIEW FRONT VIEW TOILET & ACCESSORY MOUNTING DETAIL PER SECTION 4.16 A.D.A. HANDICAP SINGLE ACCOMMODATION TOILET ROOM 3' -0" 6x MAX. i 36" MIN. GRAB BAR " MIN. 04 RESTROOM ELEVATIONS 12" MIN. I 6" MAX. HANDICAP MULTI- ACCOMMODATION TOILET ROOM PER SECTION 4.17 A.DA AF -24 WALL t t I. • \ ADA TRAP GUARD 6" MAX. TOE CLEARANCE. 8" MIN. KNEE CLEARANCE MOUNTING HEIGHTS 4' -0' MIN. CLEAR FLOOR SPACE WALL AS SCHEDULED GRAB BAR 1 -1/4" TO 1 -1/2 NOMINAL DIAMETER PROVIDE (3) #10 SCREWS EACH GRAB BAR FASTENER LOCATION. PROVIDE 2X6 BLOCKING BETWEEN STUDS ® EACH GRAB BAR LOCATION. PER SECTION 4.26 A.D.A. B CLEAR FLOOR SPACE PER SECTION 4.19 A.D.A. MIRROR OF FIXTURE /- WALL 48" MIN. I 48" MIN. it , . Tv; g HIGH FORWARD REACH LIMIT X SHALL BE LESS THAN OR EQUAL TO 25 INCHES. Z SHALL BE GREATER THAN OR EQUAL TO X. WHEN X IS LESS THAN 20 INCHES. THEN Y SHALL BE 48" MAXIMUM. WHEN X IS 20 TO 25 INCHES, THEN Y SHALL BE 44 INCHES MAXIMUM. MAXIMUM FORWARD REACH OVER AN OBSTRUCTION PER SECTION 4.2 A.DA DOOR MOUNTED SIGNS " ADA SIGNS C ADA ROOM IDENTIFICATION DOOR MOUNTED SIGN (1/4" THK.) SIGN (1/4" THK.) (CALIFORNIA ONLY) LATCH SIDE OF DOOR PER SECTION 4.30 A.DA 44" MIN. 4 NOTES 1. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND. 2. IDENTIFICATION SYMBOLS ARE TO BE ON WALL ADJACENT DOOR 60" ABOVE FLOOR AND ARE TO BE DISTINCTLY DIFFERENT FROM DOOR AND WALL IN COLOR AND CONTRAST. 3. PROVIDE ROOM IDENTIFICATION SIGN ON LATCH SIDE OF DOOR. 4. LETTERS & NUMBERS ON SIGNS SHALL BE RAISED 1/32" MIN., SHALL BE A MIN. OF 5/8" HIGH SHALL BE SANS -SERIF UPPERCASE CHARACTERS. A.D.A. SIGNAGE ACCOMPANIED BY GRADE 2 BRAILLE. 5 . REGULATORY SIGNS TO BE TYPICALLY ADA COMPLIANT TACTILE 3 -D PLAQUES PER CODE REQUIREMENTS. POS%-071 1 AF -21 1 I I PUSH SIDE FRONT APPROACH PUSH SIDE 54" MIN. 60" MIN. PULL SIDE SIDE APPROACH PER SECTION 4.13 A.DA &g, ROVIDE THIS I ADDITIONAL SPACE IF PULL IIDE DOOR IS EQUIPPED WITH BOTH A LATCH AND A I CLOSER. 24" MIN. CLEAR AT EXTERIOR DOORS 18" . INTERIOR MIN DOORS AT P., c U o oa m am a 1 Jj 1 • � 0 m 6. SIGNS TO BE A TYPICAL ONE PIECE INJECTION MOLDED FABRICATION WITH RAISED SECOND SURFACE GRAPHICS. 7. SIGN TO BE A CUSTOM COLOR TO MATCH PMS 262C WITH WHITE GRAPHICS. 8. BRAILLE SHOWN IS FOR PLACEMENT ONLY. USE CORRECT BRAILLE FOR SIGN PRODUCTION. D ED I Cone Com'�` APPR .n„ j B3 -r'L64C. rAa RECEIVE' FEB - 8 2008 PERMIT CENTP° co oo 5 rts CJ) HEALTH DEPT SUBMITTAL 98% OWNER REVIEW HEALTH DEPT RVSNS ISSUED FOR PERMIT Cl • ISSUED / REVISED DATE 12.17.07 01.03.08 01.11.08 01.25.08 RESTROOM PLAN & ADA GUIDELINES A -1.2 F E D C 5 6 7 9 10 REMOTE STOCK ROOM 05 REFLECTED CEILING PLAN 1/4" = ,7 r i NTS FASTEN TO STEEL FRAMING, WOOD FRAMING, CONCRETE STRUCTURE, EL C CI DECK K -4 ( U ES DECK 3 4, ASR REPORT 4071 (ITEM 2.2.2), HANGER WIRES, RODS OR FLATS - [ SIZE AND SPACING PER ASTM C754, AND NO MORE THAN 6" FROM MAIN RUNNER ENDS. HAT - CHANNELS (FURRING MEMBERS) ¢=, CUPPEDOR SADDLE - TIED TO COLD - ROLLED CHANNELS (MAIN RUNNERS) - SIZE AND SPACING PER ASTM C754, BUT NOT TO EXCEED 16" ON CENTER. L'S NOTE: ALL SUPPORTS TO BE FROM STRUCTURAL BEAMS AND JOISTS AND NOT FROM DECK ABOVE, 1" MINIMUM -6" MAXIMUM WHERE MAIN PREP ROOM RESTROOM 5/8" GYPSUM BOARD COMPLYING WITH IBC SECTION 2506 FROM MASONRY OR CONCRETE WALLS FROM WALL TO MAIN RUNNER RUNNER IS PARALLEL TO WALL NOTE: COMPLY WITH ADDITIONAL PROVISIONS OF IBC SECTION 2508 14 GONB. SUSPENSION DETAIL TYPICAL INSTALLATION 3' -8" B2 PA .. PA —0 r - f r 1/4 = 1 - 0 " 6' -0" MAX LATERAL SUPPORT POINT WITHIN 6' -O" OF EACH WALL f 8"MAX _JIHHH nu mm u nu IHHHHH uuuuIquuuuH a muuuuuum HHHIMlwlnun HHIP BOLT COMPRESSION STRUT AT TOP AND BOTTOM r 12' -0" O.C. EACH WAY TO LATERAL SUPPORT POINT TRAPEZE AS NECESSARY AVOID OBSTRUCTIONS j MAIN TEE OR C 'SS TEE SUSPENSION MAINTAIN HANGER WIRE ( LA RR# 22179) ! SPACING AND CAPACITY i mu uu uuumm ACOUSTICAL CEILING PANELS (LA RRI 22069) Er I OTE COMPLY WITH ALL ADDMONAL PROVISIONS OF Aset ckw4 4•1 NTS CL OPENING 02 REFLECTED CEILING PLAN LL'S NOTE: ALL CONNECTIONS TO METAL DECK SLABS FOR STRUCTURAL LOADS SHALL BE EITHER PRESET OF DRILLED IN ANCHORS. PERIMETER SUPPORT 12 SUSPENDED CEILING TILE FCL BACKBAR 4'--0" 2' -0" 2' -0" 4' -0" 3' -O" 2' -8" , 1'`J 3,/8 I I I / I I I P I I 1 I I R pub-.077 SCALE 1/4' = 1' 0 2 4 S 000 NORTH LIGHTING LEGEND & KEY NOTE ALL LIGHT FIXTURES TO BE SUSPENDED FROM STRUCTURE. RCP SYMBOL V TX CI n 0 I l Hcal ool o of REF. No. TA T2 T4 T6 T8 SD SA RA PA SR XC XW BP CEH WMEH FC B2 B2A FIXTURE DESCRIPTION GENERAL NOTES TRACK HEAD - FIXTURE AND BACK WALL LIGHTING TWO FOOT TRACK -WHITE FOUR FOOT TRACK -WHITE SIX FOOT TRACK -WHITE EIGHT FOOT TRACK -WHITE TRACK FEEDS -WHITE FLEXIBLE CONNECTORS -WHITE DOWNLIGHT -SALES AREA ADJUSTABLE DOWNUGHT- DISPLAY TABLES DOWN LIGHT - ISLAND FIXTURE PENDANT -SELF CONSUMPTION FIXTURE - B.O. FIXTURE ® 80 AFF STRIP LIGHTING -STOCK ROOM EDGELIT EXIT SIGN -SALES AREA WALL MOUNT EXIT SIGN -STOCK ROOM BATTERY PACK -STOCK ROOM EMERGENCY GIMBAL LIGHT -SALES AREA WALL MOUNT DUAL EMERGENCY HEAD -STOCK ROOM TOILET ROOM FAN /LIGHT COMBO DOWN UGHT - SEMI - RECESSED ADJUSTABLE DUAL LAMP DOWN LIGHT - SEMI - RECESSED ADJUSTABLE DUAL NARROW LAMP SYMBOLS LEGEND ROOM ROOM NAME FCL- FIXTURE CENTER UNE r # ## k ROOM NUMBER E CEILING MATERIAL CEILING HEIGHT C CEILING FINISH A. AN AUTOMATIC FIRE SPRINKLER SYSTEM & ALARM SYSTEM ARE EXISTING SPACE. EXTEND SPRINKLER HEADS DOWN TO NEW CEILING HEIGHTS. B. PROVIDE SERVICE ACCESS PANELS IN ALL HARD SURFACE CEILINGS FOR ALL MECHANICAL EQUIPMENT. SERVICE ACCESS PANEL MUST BE FLUSH EMPLOY ONLY CONCEALED HARDWARE. WITHIN THIS ACCESS TO MOUNTED AND SHEET NOTES 1. LEASE LINE, DENOTES EXTENT OF WORK. 2. NEW VENTROL UNIT - REFER TO ELECTRICAL DRAWINGS FOR MORE INFORMATION. 3. UNE OF CEIUNG TRANSITION 4. T.G.C. TO PROVIDE 6' BATT INSULATION ABOVE CEILING IN STOCK ROOM. DO NOT PLACE INSULATION OVER RETURN AIR GRILLES. 5. REPLACE LAMPS IN EXISTING UGHT FIXTURES. 6. PROVIDE 18 GA. 6" STUDS 1. 16" O.C. AT RESTROOM CEILING AND 3/4" PLYWOOD DECK ABOVE 7. LINE OF MALL BULKHEAD ABOVE. 8. ACT -1 CEILING TILE TO EXTEND OVER LOWER RESTROOM CEILING. 9. PAINT EXISTING GRID AS REQUIRED TO PROVIDE A "LIKE -NEW" CONDMON. 10. T.G.C. TO VERIFY CONDITION OF EXISTING INSULATION AND REPLACE AS NEEDED. LANDLORD NOTES 1. STOREFRONT SIGNAGE MUST BE INCANDESCENT, ON SEPARATE CIRCUIT AND ON 7 DAY TIME CLOCK SET TO MALL'S OPERATING HOURS. 2. ALL SPRINKLER HEADS IN THE FORWARD SEWNG AREA ARE TO BE CONCEALED POP OF COVER TYPE. RECENN e FEB -8 ZOOS PERMIT CEN"I L i 1- 2 0 H Q W H 0 o 4 0 ISSUED / REVISED DATE HEALTH DEPT SUBMITTAL 12.17.07 98% OWNER REVIEW 01.03.08 HEALTH DEPT RVSNS 01.11.08 ISSUED FOR PERMIT 01.25.08 REFLECTED CEILING PLAN A -2.0 FINISH MATERIAL SCHEDULE ROOM FINISH SCHEDULE SYM. MATERIAL MANUFACTURER TYPE /COLOR SIZE REMARKS ROOM FLOOR BASE WALLS CEILING REMARKS N S E W FLOORING MF -1 To Match Mall Tile Mall Operations Manager Verify With Mall Management Varies Coordinate With Mall Management T.G.C. To Supply & Install SYMBOL SYMBOL FINISH FINISH FINISH FINISH MAT. PAINT HEIGHT LM -2 Limestone Mosaic Tile Floor Virginia Tile Vir 9 SKIS Mosaics #06 Azul Marlene Polished 5/8 "x5/8 ° x3/8 ° Thick 12 "x 2" Sheets Supplied By Tenant & Installed By T.G.C. 101 SALES AREA PT--1 BW -1 P -2 P -1 P -1 P -1 P -1 GBC -1 P -1 VARIES • REFER TO INTERIOR ELEVATIONS " Grout: Use GT -1 PT -1 Porcelain Ceramic Tile Ceramic Tile International Porcelain Model #5553 & Finish: Honed 14" x 14" x 5/16" Supplied By Tenant & Installed By T.G.C. 102 PREP ROOM QT-- " B -1 P-3 P -3 P -3 P -3 ACT -1 N/A 10' —o' VCT -1 VCT Armstrong #51883 "Dusty Miller" 12" x 12" x 1/8" T.G.C. To Supply & Install QT -1 Quarry Tile American Olean #006 ''Fawn Grey" 6" x 6" x 1/2" T.G.C. To Supply & Install 103 RESTROOM QT -1 5" BQ -1 P -3/ FRP -1 P -3/ FRP -1 P -3/ FRP -1 P -3/ FRP -1 ACT -1 N/A 7'-6" BASE BV -1 Vinyl Base Armstrong #71 "Mid Gray 4" High T.G.C. To Supply & Install BW -1 Wood By F.C. Painted "P--2" By T.G.C. 1/2" x 12" High Supplied & Primed By F.G. & Installed & Painted By T.G.C. BQ -1 Quarry Base American Olean #Q3565 Cove Base 5" x 6" High w/ Min. 3/8" Cove Radius T.G.C. To Supply & Install Color: Q06 "Fawn Grey" BP -1 Porceline Ceramic Cove Base Daltile CD11 "NERO" 4" High T.G.C. To Supply & Install VERTICAL SURFACES P -1 Paint Benjamin Moore #0C -61 White Diamond (Bright White) T.G.C. To Supply & Install Finish: Lo —Sheen Eggshell . PAINTING NOTE: P -2 Paint Pittsburgh Paints #411 -1 Silvery Moon (Warm White) T.G.C. To Supply & Install Finish: Semi —Gloss ALKYD ALL PAINTING TO BE DONE BY T.G.C. AS PER SCHEDULE. ALL PAINTABLE SURFACES ARE TO HAVE 1 COAT PRIMER AND 2 COATS PAINT. ALL CEILING RETURN BOXES ARE TO BE PAINTED BLACK ON THE INSIDE OF RETURN DUCT AS FAR POSSIBLE. SALES AREA WALLS PAINTED P -1 LO- -SHEEN EGGSHELL LATEX. SALES AREA CEILINGS TO BE PAINTED P -1 LO —SHEEN EGGSHELL LATEX. • SALES AREA WALLBASE AND STOCK RM DOOR FRAMES PAINTED P -2 SEMI —GLOSS ALKYp. FLOORING AND BASE: P -3 Paint Benjamin Moore White Enamel T.G.C. To Supply & Install Finish: Semi —Gloss ST -1 Wood Stain Supplied By Tenant (Fixture Vendor) & Installed By T.G.C. CT -1 Ceramic Tile Crossville Savoy Linen VS131 3" x 6" x 3/8" Thick Supplied By Tenant & Installed By T.G.C. Glazed Tile CT -2 Ceramic Tile Crossville Savoy Linen VS131 1 1/4" x 6" x 3/8" Thick Supplied By Tenant & Installed By T.G.C. Quarter Round Bead Glazed Tile CT -3 Ceramic Tile Tagina Siena White CFF1T71 3" x 6" x 3/8" Thick Supplied By Tenant & Installed By T.G.C. Crackled Glazed Tile CT -4 Ceramic Tile Tagina Siena White CFD1TQR 1 1/4" x 6" x 3/8 ". Thick Supplied By Tenant & Installed By T.G.C. SALES AREA T.G.C. TO PREPARE EXISTING FLOOR ACCORDING TO MANUFACTURER'S SPECS AND ENSURE THAT TILE TRANSITION IS Crackled Glazed Tile SMOOTH AND EVEN. FLOOR TILE TO BE PASTE GROUT W /1/8 " JOINTS. TILE & GROUT SUPPLIED BY TENANT, INSTALLED BY T.G.G. 12" PRIMED WOOD BASE SUPPLIED BY TENANT, INSTALLED & PAINTED P -2 BY T.G.G. CEILING: LM -1 Limestone Tile Ceramic Tile International Becerra Honed 12" x 12" x 3/8" Thick Supplied By Tenant & Installed By T.G.C. Butt joints —no grout LM-2 Limestone Mosaic Wall Tile Virginia Tile SKIS Mosaics #06 Azul Marlene Polished 5/8 "x5/8 "x3/8" Thick 12 "x 2" Sheets Supplied By Tenant & Installed By T.G.C. Grout: Use "GT -1" GWT -1 Glass Tile Greneker Gold Tone Iridescent, Resin, Bar 3/4" x 7 3/4" x 1/4" Thick Supplied By Tenant & Installed By T.G.C. SALES AREA TO BE 5/8" SHEETROCK (TYPE X)(TAPED & SPACKLED) PAINTED P -1 SF -1 Metal Storefront Custom Storefronts Anodized Aluminum Varies Supplied By Tenant & Installed By T.G.C. PREP ROOM: LAY —IN ACOUSTICAL CEILING Finish: Stylmark Custom Color (Match Wilsonart #6261) RESTROOM: TO BE 5/8" SHEETROCK (TAPED & SPACKLED) PAINTED P -3 WD -1 MDF Filler Strips Parisi 10C -61 White Diamond (Bright White) Supplied & Primed By F.C. & Installed & Painted By T.G.C. Finish: Lo —Sheen Eggshell BM -1 Wood Batten Moulding By F.C. Painted "P -1" By T.G.C. 3/4 " x 10' —O" lengths Supplied & Primed By F.C. & Installed & Painted By T.G.C. CM -1 Wood Crown Moulding By F.C. Painted "P -2" By T.G.C. 7 1/2" x 8' —O' lengths Supplied & Primed By F.C. & Installed & Painted By T.G.C. FRP -1 Fiberglass Reinforced Panel By T.G.C. Standard White 10' — 0" Length Sheets T.G.C. To Supply & Install: Install so There Are No Horizontal Seams /Joints. FIXTURES /GROUT GT -1 Grout TEC Grout #927 Light Pewter (Two Part) Epoxy Grout Supplied By Tenant & Installed By T.G.C. To Be Used With "PT -1" & "LM -2" GT -2 Grout TEC Grout #931 Standard White Supplied By Tenant & Installed By T.G.C. 000 ...077 03 REV1tV` ) rte" CODE COMPLIANCE 1 APPROVE D \ FE 1 ?�i Cl �u` BI I� `���`'- k EXTERIOR MALL TILE FLOORING 1/8" X 1/2" BRASS DMDER STRIP PORCELAIN FLOORING PT -1 THIN SET MORTAR CONCRETE SLAB DETAIL To Be Used With "CT -1 ", "CT -2 ", "CT -3" & "CT -4" GT -3 Grout TEC Grout Standard Grey T.G.C. To Supply & Install To Be Used With "QT -1' & "BQ -1" M -1 Metal Laminate Wilsonart Laminate #6261 Satin Brushed Medium Bronze Aluminum Laminate 1/4" Thick For Fixtures, Sign & Storefront MB -1 Marble Calcutta Gold Marble Fixtures Countertop 5S -1 Corian Du Pont Cameo White Corian Fixtures Countertop & Backbar Backsplash GL -1 Glass Bendheim #JGA -24 White Milk Glass For Fixtures WD-2 Wood Parisi Plain Sliced Ash -- Stained White For Fixtures WD -3 Wood Parisi Quartered Ash Stained Dark Charcoal Standard Stain For Fixtures ACCENT A -1 Resin Trim Greneker Bronze 8" W x 1 1/2" Thick Supplied By Tenant & Installed By T.G.C. A -2 Resin Trim Greneker Bronze 3 1/2" W x 3/8" Thick Supplied By Tenant & Installed By T.G.C. Frames Wallcases. CEILING GBC -1 Gypsum Board Ceiling By T.G.C. Painted "P -1" By T.G.C. 5/8" Type "X" Gypsum Board T.G.C. To Supply & Install ACT -1 Acoustical Tile (Stockroom) USG Clean Room Climaplus Class 100 Panels Fine 48 "x24 "x5/8 " Thick For Rated and Non —Rated Ceilings — TRANSITION Textured With Vinyl— Laminated Face Item #56091 Tile Color. White Grid: Donn CE Grid System With Gasketed Tee Flanges (White) ACT-2 Acoustical Tile (Sales Area) USG Sandrift Climaplus — Sheetrock Brand Lay —in Ceiling Panel 24 "x24 "x5/8 " Thick For Rated and Non —Rated Ceilings Climaplus Vinyl #3260 Tile Color. White Grid Color. White —TGC to Verify color match Grid: Existing Adjusted to Accomodate 2x2 Tiles 3" = 1' -0" PORCELAIN FLOORING PT -1 1/8" X 1/2" BRASS DMDER STRIP QUARRY TILE QT THIN SET MORTAR CONCRETE SLAB REC VE[^ FEB — 8 2008 PERMIT CENTEE DETAIL _ ,,--" 01 TRANSITION *.... - 3 " = 1 ' -0 „ 6 10 03 5 Lct Q? 98% OWNER REVIEW HEALTH DEPT RVSNS ISSUED FOR PERMIT ISSUED/REVISED DATE HEALTH DEPT SUBMITTAL 12.17.07 01.03.08 01.11.08 01.25.08 ROOM FINISH SCHEDULE & DETAILS A -3,0 a I II II f' r fr T ._ �i 1f . bii G o i —,z ,, G DI Clr..l., A a I II II T ._ �i 1f . bii G o i —,z 1 3M -1 i 4 5 6 7 8 40) 13' -7" MALL BULKHEAD 3/4" X 3/4" CLEAR ANODIZED ALUM REVEAL 0 LL'S NEUTRAL PIER O' -0" FINISHED FLOOR TYP Q o LL'S NUETRAL PIER EQ -1B — 1 / 4" = 1 - 0 ° BQ -1 �EQ -19> EQ -11> 15 INTERIOR ELEVATION BEYOND EDGE OF DOOR WH POSITION - ( '- FINISH FLOOR — 1 /4" = 1' -0" OUTLINE OF DIPPER UNIT 09 INTERIOR ELEVATION PIN MOUNTED BRASS 3/4" X 3/4" CLEAR ANODIZED 1/2" ACRYLIC PUSH LOGO LEIIrRS ON ALUM REVEAL 0 MALL THROUGH LETTERS - UMES FACE TONE TILE BULKHEAD BRASS TT _.._ WINDOW SLAB W /UGHTBOX WINDOW SLAB W/LIGHTBOX BEYOND 05 EXTERIOR ELEVATION (© STOREFRONT) 1/4- = 1' -0" 14 INTERIOR ELEVATION 1/4 = 1 ,_ 0 " ILLUMINATED LOGO /SIGNAGE 'n111 Mr CORE CABINET O i 13' -7 MALL BULKH 0 FINISHED FLOO odi 12' -10 1/4" If SALES FLOOR CEILING FINISH FLOOR 4I1F -01 WINDOW SLAB SHELF ILLUMINATED LOGO /SIGNAGE 1/ = 1' - 4F-D4B BACK COUNTER 12 INTERIOR ELEVATION 07 INTERIOR ELEVATION - 1/4- = 3/4" X 3/4" CLEAR ANODIZED ALUM REVEAL ® MALL BULKHEAD 1/2" ACRYLIC PUSH THROUGH LETTERS DIPPER FIXTURE BEYOND 03 EXTERIOR ELEVATION (@ STOREFRONT) 1/4- - 1' -0" WINDOW SLAB SHELF 3/4 X 3/4" CLEAR ANODIZED ALUM REVEAL ® LL'S NEUTRAL PIER LL'S NUETRAL PIER APPLIED LOGO IMAGE EDGE OF SLIDING GLASS DOOR WHEN IN ° OPEN" POSmON b ‘.611 CODE CO MPLIA w 4 ` GENERAL NOTES A. SIGN VENDOR TO SUBMIT SIGN VENDOR SHOP DRAWINGS FOR TENANT COORDINATOR AND LANDLORD REVIEW /APPROVAL. !r 1 FEB - 8 2008 PERMIT CENTEFi SYMBOL KEY INDICATES FINISH MATERIAL, REFER TO FINISH SCHEDULE ON SHEET A -3.0 INDICATES TENANT FIXTURE REFER TO FIXTURE SCHEDULE ON SHEET F -1.0 FOR ADDff1ONAL INFORMATION 9 10 O LL H 0 U) > &t, EEMEE HEALTH DEPT SUBMITTAL 98% OWNER REVIEW HEALTH DEPT RVSNS ISSUED FOR PERMIT A -4.0 CO 1- W 5 (D a.. c3 Ch Q ISSUED / REVISED DATE 12.17.07 01.03.08 01.11.08 01.25.08 ELEVATIONS 4325 Tam-O-Shanter Way, Dayton, OH 45429 I p 937 477 2334 info@rnoda4.com MODA4 PROJECT NUMBER: 07009 555 Southcenter Ij 0'-on Y FINISH FLOOR 1 LIGHT COVE BY LANDLORD EXISTING LANDLORD'S BULKHEAD � -7" AF.F. VIF Y BOTTOM OF MALL BULKHEAD 3/4" X 3/4" CLEAR ANODIZED ALUMINUM R 1/2" DUROCK 12' -10 1/4" A.F.F. TOP OF ALUM /SALES FLOOR CLN CUSTOM RESIN TILE LEASE LINE 1/2" TEMPERED GLAZING BY T.G.C. I EXISTING MALL TILE - G.C. TO EXTEND EXISTING MALL TILE FROM EXISTING MALL TILE AT LEASE LINE TO GODNA'S STOREFRONT BASE. TILE TO MATCH EXISTING MALL TILE IN TYPE, COLOR, SIZE, THICKNESS, GROUT COLOR AND INSTALLATION DIRECTION. NO THRESHOLD, REDUCER STRIP OR OTHER WIDE TRANSITION DEVICES AT INTERSECTION OF GODIVA'S FLOORING & MALL TILE. WHEN EXTENDING MALL TILE TO GODIVA'S STOREFONT BASE, TILES MUST BE FULL TILE. IF THE MALL TILE IS CUT, IT MUST BE REMOVED AND REPLACED WITH FULL TILE EXISTING CONCRETE SLAB N 2 05 SECTION @ STOREFRONT 1 " 1 ' 1-1/2" _ 1' -0" 5/8" TYP "X" GYP. BD. 5/8" GYP. BD. 3 T.G.C. TO PROVIDE F.R. BLOCKING AS REQUIRED LL'S CONSTRUCTION 4 3/4" X 3/4" CLEAR - ANODIZED ALUMINUM REVEAL CUSTOM RESIN TILE OVER UMESTONE 1 1/2" = 1 -0" 3" = 1 -0" l LIMESTONE TILE OVER ' 1/2" DUROCK 14 PLAN DETAIL SLIDING GLASS DOOR 09 PLAN DETAIL LIMESTONE TILE OVER 1/2" DUROCK DEMISING WALL ASSEMBLY PER WALL TYPE & LL'S REQUIREMENTS F.T. BLOCKING AS REQUIRED 20 GA. 6" MIL STUDS ® 16" O.C. 4" X 6" ALUMINUM f SF -1. PROVIDE FULL SOLID BLOCKING OW GANG STUDS BELOW. 1/2" TEMPERED GLAZING 1 5 EXISING NEUTRAL PIER 20 GA. 2. STUDS 5/8" GWB (2) LAYERS 1/2" GYP. BD. 1/2" DUROCK 3/8" CERAMIC TILE 1/4" MASTIC 1/8" GROUT JOINTS 1/2" TEMPERED GLAZING ALUMINUM STOREFRONT SYSTEM 4" 16 GA MTL STU 12 O.C. FASTEN TO SLAB PER TYPICAL WALL TYPE DETAIL 3/4" FRT PLYWOOD MALL TILE 6 CLADDING /WRAP uslirm „ =1' -0" 1 1/2" = 1' -0" 07 SILL DETAIL 12 PLAN DETAIL DEMISING WALL ASSEMBLY PER WALL TYPE & LL'S REQUIREMENTS 6" 7 ANCHORING SCREWS 0 18" O.C. FRT 2x6 SILL/BLOCKINNG -- NEW FLOOR TILE SLIDING GLASS DOOR TRACK 8 EXISTING NEUTRAL PIER 3/4" X 3/4" CLEAR ANODIZED ALUMINUM REVEAL UMESTONE TILE OVER 1/2" DUROCK CUSTOM RESIN TILE 20 GA. 4" MIL. STUDS © 16" O.C. 1/2" DUROCK 2x F.T. BLOCKING AS REQUIRED ANCHORING SCREWS ON EACH END & EVERY 18" O.C. BETWEEN ALUMINUM STOREFRONT SYSTEM 9 , k 1 HR RATED WALL ASSEMBLY - RECESSED TRACK FOR SLIDING DOOR LEASE UNE I f6'l 01 ENLARGED PLAN © STOREFRONT 1- '1/2" = P O B ?71 i L3 Fc., ` CODE COMPLIA N AApR Eu 10 EXISTING NEUTRAL PIER 1 HR RATED WALL ASSEMBLY FEB UNE OF CEILING HEIGHT TRANSITION ABOVE ■ h RECEIVE FEB -8 2008 PERMIT CENTER HEALTH DEPT SUBMITTAL 98% OWNER REVIEW HEALTH DEPT RVSNS ISSUED FOR PERMIT I ISSUED / REVISED DATE 12.17.07 01.03.08 01.11.08 01.25.08 STOREFRONT SECTIONS & DETAILS A -5.0 1 2 3 EXISTING MALL BULKHEAD 3/4" X 3/4" CLEAR ANODIZED ALUMINUM REVEAL CUSTOM RESIN TILE 1/2" DUROCK MTL FRAMING 4 FIRE RETARDANT BLOCKING AS REQUIRED 12' -10 1/4" A.F.F. TOP OF STOREFRONT OPENING ALUMINUM STOREFRONT SYSTEM A -1 1/2" TEMPERED GLAZING OR SIGN BOX r'. 1 1/?" LEASE UNE n 5 7/8" 5 5/8" GYP. BD. PROVIDE ANCHORING © 18" O.C. 14 DETAIL a0 STOREFRONT HEAD 3 " = 1, -0" SIGNBOX PROVIDED BY TENANT & INSTALLED BY TENANT SIGN VENDOR LEASE UNE 2" X 6" ALUMINUM TUBE SUPPUED BY TENANT & INSTALLED BY T.G.C. — 10' -0" A.F.F. BOTTOM OF HORIZONTAL MULUON 1 1/21 SLIDING DOOR TRACK HEAD SUPPLIED BY TENANT & INSTALLED BY T.G.C. 09 DETAIL @ STOREFRONT ENTRY HEAD 3 „ = 11-0" O '— O " FINISH FLOOR N L J V' n SLIDING DOOR BY TENANT SLI ING DOOR TRACK SU PLIED BY TENANT & IN ALLED BY T.G.C. INSTALL MALL TAE UP TO STOREFRONT AND UP TO E DOORS. TENANT IS RESPONSIBLE FOR ALL TILE 1' -0" OUT FROM LEASE UNE INTO THE MALL COMMON AREA. SEE ON —SITE COORDINATOR TO PURCHASE MALL TILE. I SHIM TRACK AS NEEDED TO PROVIDE A FLUSH CONDITION WI FLOORING MATERIAL NEW FLOORING AS SCHEDULED 6 04 DETAIL @ STOREFRONT ENTRY TRACK *m... 3" = 1 1_ 0 " LIGHT COVE BY LANDLORD 4 / / ' , s s j , 7 / ,` 7 _ / . f ` , / / / ' , f / /- EXISTING LANDLORD'S BULKHEAD (. 13' -7" A.F.F. VIF Y TOP OF STOREFRONT 1/2" DUROCK - 12' -10 1/4" A.F.F. TOP OF ALUM /SALES FLOOR CLN CUSTOM RESIN TILE LEASE UNE 1/2" TEMPERED GLAZING BY T.G.C. SIGNBOX PROVIDED BY TENANT 10' -0" A.F.F. BOTTOM OF HORIZONTAL MUWON EXISTING MALL TILE — G.C. TO EXTEND EXISTING MALL TILE FROM EXISTING MALL TILE AT LEASE UNE TO GODIVA'S STOREFRONT BASE. TILE TO MATCH EXISTING MALL TILE IN TYPE, COLOR, SIZE, THICKNESS, GROUT COLOR AND INSTALLATION DIRECTION. NO THRESHOLD, REDUCER STRIP OR OTHER WIDE TRANSITION DEVICES AT INTERSECTION OF GODIVA'S FLOORING & MALL TILE. WHEN EXTENDING MALL TILE TO GODIVA'S STOREFONT BASE, TILES MUST BE FULL TILE. IF THE MALL TILE IS CUT, IT MUST BE REMOVED AND REPLACED WITH FULL TILE EXISTING CONCRETE SLAB V.I.F. N a 5/8" TYPE " X " GYP. BD. 5/8' GYP. BD. T.G.C. TO PROVIDE F.R. BLOCKING AS REQUIRED \ J V 9 , 02 SECTION @ STOREFRONT ENTRY '--- 1 /2 " = 1 1_ 0 „ 10 CODE COMVLIANCE APPROVE \ City Of T&N‘15 B UILDIMIG R Da •b77 FEB -8 ZUud PERMIT CENTEIr eg 'F W w 0 W 0 OMMEUM ISSUED / REVISED DATE HEALTH DEPT SUBMITTAL 12.17.07 98% OWNER REVIEW 01.03.08 HEALTH DEPT RVSNS 01.11.08 ISSUED FOR PERMIT 01.25.08 STOREFRONT SECTIONS & DETAILS A -5.1 X" IN FRONT OF SHEETROCK 1 2 9fi" SHEETROCK 1" FILLER SCREW TO SIDE WALL OF ALCOVE BELOW CABINET LINE f � l !! 1" FILLER LINE OF ' ' [CABINET / " iHEETROCK SPACE 2 1/4' 5/8" SHEETROCK 3/4" BATTEN ) FILLER SUPP. BY PARISI ESIN TILE SUPP. BY GRENEKER DETAIL A UPPER SECTION SCALE: 3" =1' -O' PLAN SECTION THRU BASE CABINET D - Y" FILLER SUPP. BY PARISI RESIN TILE SUPP. BY GRENEKER LINE OF CABINET DETAIL B LOWER SECTION SCALE: 3 6'-• -8 1/2 HOLD FINISH OPENING NOTE THERE WILL BE X" SHIM SPACE BEHIND UPPER CUBES. 6' -7 1/2 UPPER CUBES PLAN SECTION THRU UPPER DISPLAY CUBES WILL BE SPACE FOR EXPOSED GREENFIELD ON REAR OF CABINET. CABINET ITSELF DOES NOT SIT AGAINST THE WALL BASE CABINET BOTH TYPES 1" FILLER 5/8" SHEETROCK 3/4" BATTEN 05 FIXTURE /ALCOVE INSTALLATION DETAILS VARIES DETAIL C UPPER SECTION SCALE: 3' =1' -O' 4 1/4" SHIM SPACE SHEETROCK SET CUBES 1/2 IN FRONT OF SHEETROCK i FILLER SHEETROCK j f FILLER MUST COME 1/2" IN FRONT OF SHEETROCJC )2" FILLER SUPP. TE L 3 5 /g" METAL STUD A" SHEETROCK DISPLAY CUB E S ..... W ................... CABINET IS 7 IN FRONT OF SHEtIROCK RESIN TILE 1' -1 3/4" SHEETROCK DIMENSION vA 13 DETAIL @ STOCK ROOM SHELVING 1 " ^ 1' -0" CM -1 3/4" BATTEN GWB 12" WOOD BASE 08 DETAIL Ubmmm 1 „ = 1 ' 0 GYP. BD. CEILING HT. VARIES SEE RCP 0 N (V 5 BEMS 1 /2 = 1 - 0 " I 11 1' -6" , c li ly ■■I (-0" MAX REFER TO PLAN vA 03 ELEVATION / LAY -IN ACOUSTICAL CEILING AS SCHEDULED WHITE F.R.P. PANELS OVER 1/2" NON -COMB PLYWOOD SECURE TO WALL, FLOOR TO CLG. WHERE SHELVING IS TO BE MT'D. SUPP. & INST. BY T.G.C. MTL STUDS AS SCHEDULED WALL BRACKETS WITH CLAMPS, FASTENED THROUGH PLYWOOD, SUPP. BY TENANT AND INST. BY T.G.C. 18" DEEP WIRE SHELVES, SUPP. BY TENANT AND INST. BY T.G.C. \ 6 7 WATER HEATER 3 5/8" 20 GA. MTL STUDS © 16" O.C. 3/4" F.R.T. PLYWOOD 11' -0 3/4" A.F.F. TOP OF SHELF V 6 "20 GA. MIL STUDS 0 16" O.C. 5/8" GYP. BD. 10' --0" AF.F LAY -IN CEILING 1 t' @ WATER HEATER PLATFORM r / / 3/8" 1/4" MDF BATTEN \\ GYPSUM BOARD WALL tt 12" WOOD BASE @ INTR SALES AREA (TYP) Poo ++ ++ Lam: 1' -1 3/4" w 2 co o ++ + 5/8" GYP. BD. CM -1 8 GYP. BD. CEILING di REFER TO RCP CONDITION SIMILAR B CONDITION A BOTTOM OF SOFFIT Y di 9' -10" A.F.F. 3 5/8" MTL. STUDS 20 GA. 0 16" O.C. TO STRUCTURE ABOVE PER LL DESIGN CRITERIA 3 5/8" MTL STUDS 20 GA. ® 16" O.C. REFER TO ALCOVE INSTALLATION DETAILS THIS SHEET BUILT -IN CABINET - REFER TO FIXTURE DRAWINGS FOR MORE INFORMATION 5/8" GYP. BD. FINISH FLOOR 0' -0" Y 02 SECTION @ CABINET ALCOVE 1 " = 1 ,_ 0 „ 5/8" GYPSUM BOARD OVER LANDLORD'S DEMISING WALL PRINTABLE CAULK/ SEALANT 1 /4" MASTIC ADHESIVE 1/2" CEMENTITIOUS SUBSTRATE ON METAL STUDS FOR TILE SUBSTRATE WALL TYPE PER PLAN CERAMIC TILE BEAD APPLIED TO CORNERS 3/8" CERAMIC TILE WRAPS FOCAL WALL NOTE ORIENTATION MAY DIFFER FROM PLAN 11 WALL TILE EDGE DETAIL 3 " = 1'-0" / 9 I / t ;5: �.;62:0.0iJ :ZAW:'• ;iJ2 :i52 i56:!f »iJ WALL TILE 3 "x"x3 /8"TH � F(l n BY GODIVA & 6 INST. BY T.G.C. FROM t L.I D NCCE OVER 1/2" DURDCK CEILING W /MASTIC TO FLDO ` PER CO ©E �� C �� P � �� MANUF. SPECIFICATIONS. BACK WALL PER FLOOR PLAN CONTINUOUS 2X WOOD BLOCKING SUPPLIED AND INSTALLED BY T.G.C. WF -05 SHELF SUPP. BY F.C. INST. BY T.G.C. SHELF SUPPORTED BY 2" SQUARE METAL POSTS WALL TILE 3 "x6 "x3 /8"TH BY GODIVA & INST. BY T.G.C. FROM CEILING TO FLOOR OVER 1/2" DUROCK W /MASTIC PER MANUF. SPECIFICATIONS. 4' F.C. ED BY T.G.C. f / / / r / / / / BACKSPLASH BY f ///`,/..:f //////////, ', /7/ 1/8 GROUT JOINTS TYPICAL CD M 01 SECTION a BACK BAR 1„ 1, -0" 10 GYP. BD. CEILING ah REFER TO RCP FEB 1 2G08 City Of I.0 w b BUILDING D IS CD TOP OF SHELF 6' -1 1/8" A.F.F. 5/8" GYP. BD. RECEDED FEB -8 2008 PERMIT CENTEF FINISH FLOOR LEEREEERI yo- co co O co N O < Q "Ca' N co CI) ISSUED / REVISED DATE HEALTH DEPT SUBMITTAL 12.17.07 98% OWNER REVIEW 01.03.08 HEALTH DEPT RVSNS 01.11.08 ISSUED FOR PERMIT 01.25.08 INTERIOR DETAILS A -5.2 E U EQUIPMENT IDEN. SYMBOL DESCRIPTION MANUFACTURER MODEL N.S.F. OR EQUAL HDAT SUPPLIED BY EQ-01 O TEMPORER HIWARD TABLETOP N.S.F. N/A GODIVA EQ-02 N/A GODIVA F- 01B BLENDTEC BLENDER BLENDTEC BDI NARROW N.S.F. COLD GODIVA EQ -02A N/A GODIVA F- 01C BLENDTEC BLENDER BLENDTEC SMOOTHERS 13 SPACE SAVER N.S.F. N/A GODIVA EQ -03 NUT SHOWN ON PLAN RED RINSER (FOR BLENDER) BLENDTEC RED RINSER N.S.F. HOT GODIVA EQ-04 NOON P SHLAN OWN HOT WATER DISPENSER ZOJIRUSHI CD -L6650 GODIVA N/A GODIVA EQ -05 L REGISTER/ DIPPER COUNTER (LARGE ISLAND) DISPLAY REFRIGERATOR FOR WATER CARRAVELL ac - 125 N.S.F. COLD GODIVA EQ-06 7 T 1 J J UNDERCOUNTER REFRIGERATOR SUMMIT FF7 N.S.F. N/A GODIVA EQ -06A m L -� -� GQDIVA UPRIGHT REFRIGERATOR -- -- N.S.F. N/A GODIVA EQ -07 / T -1 J UNDERCOUNTER COMPACT FREEZER SUMMIT FS62 -7 N.S.F. N/A GODIVA EQ -08 PARISI, INC. CUSTOM I ICE CADDIE CAMBRO CAM- ICS100L N.S.F. N/A GODIVA EQ -09 PARISI, INC. CUSTOM N/A ICE MACHINE 24x28x39 HOSHIZAKI KM- 151BAH N.S.F. COLD GODIVA EQ-10 CUSTOM / 1 N/A MOP SINK 24" X 24 SUPP. BY T.G.C. AS REQUIRED N.S.F. HOT /COLD T.G.0 EQ -11 CUSTOM N/A Q I FF -06A (S 3 UBPPOWLIED L SINK W/ W AUDRAINCET) BOARDS EAGLE MANUFACTURING 310 - 10 - 3 - 12 N.S.F. HOT /COLD GODIVA EQ -12A V IM LARGE STAINLESS STEEL SINK FAUCET AND SPRAYER SUPPUED EAGLE SDI- 16- 19- 13 -5-1 N.S.F. HOT /COLD GODIVA EQ -12B 1 SMALL STAINLESS STEEL SINK FAUCET AND SOAP DISP. SUPPLIED EAGLE SDI- 10- 14 -5 -1 N.S.F. HOT /COLD GODIVA EQ-12C O "CAMEO WHITE DRAIN SINK & RACK WITHOUT FAUCET CORIAN 802 N.S.F. HOT /COLD GODIVA EQ-13 Ei LAVATORY SINK AMERICAN STANDARD LUCERNE MODEL NO. 0355.012 N.S.F. HOT /COLD TGC EQ -14 S WATER CLOSET AMERICAN STANDARD ELONGATED CADET MODEL NO. 2998.012 N.S.F. COLD TGC EQ-15 _ METAL SHELVING -AVAIL 12 ° D & 18 °D WIDTHS OF 24 ° ,36 ° & 48" ONLY METRO ERECTA N.S.F. N/A GODIVA EQ-16 WALL SHELVING (OVER MOP & 3 BOWL SINKS) METRO ERECTA N.S.F. N/A GODIVA I� EQ-17 SAFE PIONEER AS REQUIRED N/A N/A GODIVA EQ- 18 I ' STOCKROOM HAND SINK (SUPPUED W/ FAUCET) EAGLE # HSAN -10-F N.S.F. HOT /COLD GODIVA EQ -19 50 OR Mc .I PR EP PPLIED W/ INK W/ DRAI (SU FAUCNET) BOARD EAGLE MANUFACTURING 414- 16 -1 -18R or L N.S.F. HOT /COLD GODIVA FLOOR FIXTURES IDEN. SYMBOL DESCRIPTION MANUFACTURER MODEL NSF OR EQUAL WATER HOT/ COLD SUPPLIED BY FF_01A REGISTER COUNTER (LARGE ISLAND) PARISI, INC. CUSTOM N/A N/A GODIVA F- 01B I REGISTER COUNTER (SMALL ISLAND) PARISI, INC. CUSTOM N/A N/A GODIVA F- 01C MM. — SIDE BY SIDE REGISTER COUNTER VARIES PER NEED PARISI, INC. CUSTOM N/A N/A GODIVA FF -02B ENCLOSED 3-T1ER SELF CONSUMPTION CASE PARISI, INC. CUSTOM N/A N/A GODIVA , FF -03A L REGISTER/ DIPPER COUNTER (LARGE ISLAND) PARISI, INC. CUSTOM N/A N/A GODIVA 10 II FF -03B 1 REGISTER/ DIPPER COUNTER (SMALL ISLAND) PARISI, INC. CUSTOM N/A N/A GQDIVA 10 I FF -04A :::: �� p'141 , ; BACK BAR COUNTER PARISI, INC. CUSTOM N/A N/A GODIVA FF-048 BACK BAR COUNTER OPPOSITE HAND CONFIGRAIION PARISI, INC. CUSTOM N/A N/A GODIVA r1 .�� : . j Ez FF -05R 0 0 90' STOREFRONT DIPPING UNIT (RIGHT HANDED CONFIGURATION) PARISI, INC. CUSTOM N/A N/A GODIVA FF -05L 0 0 —I 90' STOREFRONT DIPPING UNIT (LEFT HANDED CONFIGURATION) PARISI, INC. CUSTOM N/A N/A GODIVA FF -06 0 SINGLE STOREFRONT DIPPING UNIT PARISI, INC. CUSTOM N/A N/A GODIVA FF -06A fI 001 DOUBLE STOREFRONT DIPPING UNIT PARISI, INC. CUSTOM N/A N/A GODIVA FF -07 1-1 SELF TREAT CASE 0 REGISTER COUNTER - 24° PARISI, INC. CUSTOM N/A N/A GODIVA FF -07A SELF TREAT CASE 0 REGISTER COUNTER - 18 PARISI, INC. CUSTOM N/A N/A GODIVA FF -08 SELF TREAT CASE FREESTANDING PARISI, INC. CUSTOM N/A N/A GODIVA I FF -09 NESTING TABLES M. LAVINE CUSTOM N/A N/A GODIVA FF -10 _ DISPLAY TOWER M. LAVINE CUSTOM N/A N/A GODI F-11 POSTER STAND-36" LOOK CUSTOM N/A N/A GODIVA C 36 F-12 POSTER STAND -42" LOOK CUSTOM N/A N/A GODIVA C 42 E D B 1 2 3 4 5 6 7 8 FIXTURE SCHEDULE INDICATES FIXTURE/ EQUIPMENT LOCATION REFER TO FIXTURE AND EQUIPMENT SCHEDULES THIS SHEET WALL FIXTURES IDOL WE-01 WF -01A WF-02 WF -02A WF -03 WF -04 WF -05A WF -05B WF -06 WF -07 WF -08 WF -09 WF -10 i SYMBOL II II II I I I I I I I ECM 1 DESCRIPTION FREESTANDING SLAB SHELF W/ HALO FREESTANDING SLAB SHELF WINDOW UNIT & LIGHTBOX FREESTANDING MINI --SLAB SHELF W/ HALO FREESTANDING SLAB SHELF WINDOW UNIT & UGHTBOX CORE CABINET CUSTOMIZATION CABINET BACKBAR SLAB SHELF (LARGE BACKBAR) VARIES BACKBAR SLAB SHELF (SMALL BACKBAR) 117) "L WALL FRAME W /ICON GRAPHIC INTERIOR FRAMES (SHOWN IN ELEVATION ONLY) MANAGER'S DESK COAT HOOKS LEANING FRAME ADJUSTABLE DISPLAY WALL MANUFACTURER PARISI, INC. PARISI, INC. PARISI, INC. PARISI, INC. PARISI, INC. PARISI, INC. PARISI, INC. PARISI, INC. PARISI, INC. PARISI, INC. PARISI, INC. PARISI, INC. PARISI, INC. PARISI, INC. MODEL CUSTOM CUSTOM CUSTOM CUSTOM CUSTOM CUSTOM CUSTOM CUSTOM CUSTOM CUSTOM CUSTOM CUSTOM CUSTOM CUSTOM NSF OR EQUAL N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A WATER HOT/ COLD N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A SUPPLIED BY GODIVA GODIVA GODIVA GODIVA GODIVA GODIVA GODIVA GODIVA GODIVA GODIVA GODIVA GODI VA GODIVA GODIVA OWNER SUPPLIED ACCESSORY SCHEDULE GODIVA SUPPLIED RESTROOM ACCESSORIES & PLUMBING FIXTURES IDEN. AF -10 AF -11 AF -12 AF -13 AF -14 AF -15 AF -20 AF -21 AF -22 AF-23 AF-24 AF -25 AF -26 AF -27 AF -30 AF -31 AF -32 AF -33 LOCATION PREP RM PREP RM PREP RM PREP RN PREP RM PREP RM RESTROOM RESTROOM RESTROOM RESTROOM RESTROOM RESTROOM RESTROOM RESTROOM BACK BAR BACK BAR BACK BAR BACK BAR ITEM MOP HANGER FAUCET FOR 3 BOWL SINK SOAP DISPENSER PAPER TOWEL HOLDER CORK BOARD STAINLESS STEEL HAND SINK SOAP DISPENSER PAPER TOWEL HOLDER TOILET PAPER HOLDER HANDICAPPED MIRROR OVER THE JOHN CABINET GRAB BAR - 30" GRAB BAR - 36" GRAB BAR -- 42" FAUCET SOAP DISPENSER PAPER TOWEL HOLDER STRAINER NEW MANUFACTURE EAGLE BOBRICK BOBRICK VARIES EAGLE BOBRICK BOBRICK BOBRICK BOBRICK VARIES BOBRICK BOBRICK BOBRICK DELTA DELTA CRATE & BARREL ELKAY SYMBOL KEY INDICATES FIXTURE/ EQUIPMENT LOCATION REFER TO FIXTURE AND EQUIPMENT SCHEDULES THIS SHEET EXISTING EXISTING ' COUNTERS /STORAGE FIXTURES PART # 300489 B -40 B253 VARIES HSAN -10 -F B -40 B253 B2740 B293 VARIES 5806 -30 5806 -36 5806 -48 2476 -H24 PR1001 OX0 SWING ARM LKS -35- 3.5" CONTRACTOR MUST VERIFY ALL JOB DIMENSIONS, DRAWINGS, DETAILS AND SPECIFICATIONS AND REPORT ANY DISCREPANCIES TO DESIGNERS BEFORE PROCEEDING WITH WORK. ARCHITECT & DESIGNER WILL NOT BE LIABLE FOR ANY ERRORS AND OMISSIONS NOT REPORTED BY GENERAL CONTRACTOR. EXISTING COMMENTS 10" FAUCET USE AT THREE BOWL AND HAND SINK USE AT THREE BOWL AND HAND SINK 18 X 36 WITH 307120 WRIST HANDLES 18 X 36 WHITE - 2 DOOR WHITE WHITE STAND UP TYPE WHITE EXISTING REMOTE STOCK ROOM 03 FIXTURE FLOOR PLAN 1 /4" = 1' -0" D (fa 02 FIXTURE FLOOR PLAN 1/4 = 1 - 0 " 9 ;~ D F I REVIEWED �JIEl�� �-� O DE rrMP! TAANCE i APPROVE SCALE 1/4' - 1' FEB 1 2 U 1 ' 6 City Of TukVViia 10 = I 0 2 4 8 w J U RECEIVEL FEB -8 2008 PERMIT CENTEk NORTH ISSUED I REVISED DATE HEALTH DEPT SUBMITTAL 12.17.07 98% OWNER REVIEW 01.03.08 HEALTH DEPT RVSNS 01.11.08 ISSUED FOR PERMIT 01.25.08 FIXTURE PLAN F -1.0 4325 Tam-O-Shanter Way, Dayton, OH 45429 I p 937 477 2334 I info©moda4 com MODA4 PROJECT NUMBER: 07009 ROUTE AT FRONT OF SHELF FOR METAL SIGN HOLDERS & CLEAR ACRYLIC FOR GRAPHICS BASE UNIT TO BE MOUNTED TO BACK PANEL AND SHELVES TO BE INSTALLED BY T.G.C. B I G B G 1 2 ROUTE AT TOP OF BACK PANEL FOR SIGN HOLDER CORD & PLUG BY PARISI BACK PANEL HALO LIGHTING (WD -3) (DARK CHARCOAL) FINISH FIXED SHELVES W/ CONCEALED UNDERLIGHT (PL =2) WHITE LAMINATE WHITE COUNTER TOP SID -3) BASE CABINET (DARK WOOD) FINISH FEED FOR LIGHTING IS 2 "AFF LIFT OUT ACCESS TO JUNCTION BOX THIS CONNECTION BY T.F.C. — BWG BY PARISI BWG JUNCTION BOX BY PARISI NOTE: TGC WILL NEED TO ASSEMBLE THIS FIXTURE. A) BACK PANEL B) SHELVES C C NTS S 1-1ELVES SHIPPED LOOSE C= I I 7 79" C J 0 I a II 7 PROJECTED WALL OUTLET LOCATION HINGED FLAP FOR ACCESS TO CASTERS 6 FT. CORD & PLUG ' I 40 / #5 NAT. ALUM. , WHITE MCP I LL a cn ISOMETRIC C) BASE UNIT a (WD-3) t- 12' eL-2 20 "D CABINET BELOW PLAN VIEW 2' -6 r BALLAST N BOX FOR SHELF T LIGHTS o- SHELV NG REQUIRES WIRING. TEC TO MAKE CONNECTION IN JUNCTION BOX. UNIT IS PREWIRED. WF-01 FREE STANDING SLAB SHELF W/ HALO -.I 1/2 " =1 ' —D " c) LINEAR FLUORESCENT FIXTURES W I (TOP & SIDES BEHIND BACK PANEL) r 7-774= FOR HALO LIGHTING AFFECT. 12 "D FIXED SHELVES W/ LINEAR LIGHT FIXTURE TO LIGHT SHELF BELOW WF-09 SHELF & COAT HOOKS 1/2 " =1' -0" BALLAST BOX BY PARISI PREWIRED — CONNECTED BY T.F.C. Y Y SHELF LIGHT ALL GREEN TIED IN BALLAST B WIRING TYPICAL FOR EACH PAIR OF SHELVES 3 PAIRS PER UNIT SHELF LIGHT DX WIRING DIAGRAM FOR SLAB SHELF W/ HALO N, 4 ROUTE AT TOP OF BACK PANEL FOR SIGN HOLDER. ROUTE AT FRONT OF SHELF FOR METAL SIGN HOLDERS & CLEAR ACRYLIC FOR GRAPHICS BACK PANEL tD 3) (DARK CHARCOAL) FINISH FIXED SHELVES W/ CONCEALED UNDERUGHT (PL -2) WHITE LAMINATE WHITE COUNTER TOP BASE CABINET (i91:73) (DARK WOOD) FINISH BASE UNIT TO BE MOUNTED TO BACK PANEL AND SHELVES TO BE INSTALLED BY T.G.C. TO JUNCTION BOX 1 NOTE: TGC, WII.I NEED TO ASSEMBLE THIS FIXTURE. L A) BACK PANEL B) SHELVES 6' CORD & PLUG FROM BALLAST BOX LIFT OUT ACCESS N 73" C � 0 SHELVES SHIPPED LOOSE X 79' C7 HINGED FLAP FOR ACCESS TO CASTERS C) BASE UNIT a 20 "D CABINET BELOW (WD -3) RECESSED FLOOR OUTLET SHELVING REQUIRES WIRING. TEC TO MAKE CONNECTION IN JUNCTION BOX. UNIT IS PREWIRED. 12 "D FIXED SHELVES W/ LINEAR LIGHT FIXTURE TO LIGHT SHELF BELOW PROJECTED FLOOR OUTLET LOCATION WF -01A FREE STANDING WINDOW SLAB SHELF 1 /2 " =1' —O" POWERED LIGHTBOX (WD -5) BALLAST BOX FOR SHELF UGHTS 6' CORD & PLUG 2 1" h �k!;1 0/D—D1 "x 13 "x56" FILLER TO SUPPORT DISPLAY b CUBE. (ONE ON EACH SIDE) SUPPLIED BY F.C. ELEVATION B 5 PANELS WILL BE SUPPLIED BY FC TO COVER SCREW HOLES FOR FASTENING — INSTALLED BY TGC i JUNCTION BOX BY F C FEED FOR LIGHTING IS 2 "AFF i � j dJl i} h I 6 CUSTOM APPLIED WALL TRIM .4 SUPPLIED BY GODIVA. INSTALLED BY TGC. SEE ALCOVE CONSTRUCTION DETAILS DRAWING FOR THE ASSEMBLY OF THIS UNIT ADJUSTABLE CUBBIES PAINTED WHITE PLEXI MUST BE INSTALLED BY TG BALLAST BOX BY F.C. FOR LIGHTS CONNECTED TO JUNCTION BOX CJ C 0 ;0 0'0..0:0 0;00 d 0 0 O 0 15" TYP_ 8Qkz' SHEETROCK TO SHEETROCK • $L 2) WF -03 CORE CABINET �- 1 / 2 " =1 , -0" o REQ'D) 0 N QUAD BOX FLOOR OUTLET FOR TEMPORERS & LIGHTING BY TGC. JUNCTION BOX IN BASE BY F.C. FOR UGHTS AND DIPPER FOR FINAL CONNECTION .g11) MARBLE COUNTER 2 &6' CUBBIES TO BE INSTALLED WITH SCREWS THROUGH BACK PANEL. — PANELS WILL BE PROVIDED TO COVER SCREWS — PANELS INSTALLED BY TGC C BRO BRONZE FINISH SNEEZE GUARD TRIM 0 N 1/2 " =1' —O" L —Z WHITE PLEXI GLASS (AID -3 DARK CHARCOAL UN QUARTERED ASHI. BRONZE fNISI- m ELEVATION A Iola 9 ELEVATION C 72,6' BRONZE FINISH SNEEZE GUARD TRIM t.TO D 1 VA Der. LS (FAB -) MARBLE COUNTER . FF -05R 90° DOUBLE DIPPER RIGHT HAND CONFIGURATION e) 1 1/2" SPACE ABOVE PLEXI— GLASS BACK PANEL PLEXI MUST BE INSTALLED BY TGC a -2) 10 ADJUSTABLE CUBES 1 %" MARBLE ti IE 1E5 F CODE COMPLIANCE APPROVED FEES ' 2Q City Of TukW i3 i BUILDING DP,c1Sf,0',‘U WHITE POWDERCOATED METAL TRIM AROUND GLOWING WHITE PANELS GODIVA LOGO SUPPLIED & INSTALLED BY GODIVA SIGN CONTRACTOR QL -2) WHITE PLEXI GLASS BRONZE. FINISH ACCESS TO LIGHT FIXTURES FROM FRONT FACE OF COUNTER 20' 1" wD -3 DARK CHARCOAL ON QUARTERED ASH REAXIVID FEB —8 2008 PERMIT CENTEs OD OD OD 0 Chi CD ▪ 4t Lit U • 0_ GO ISSUED/REVISED DATE HEALTH DEPT SUBMITTAL 98% OWNER REVIEW HEALTH DEPT RVSNS ISSUED FOR PERMIT FIXTURE DETAILS F -1.1 12.17.07 01.0x.08 01.11.08 01.25.08 1 2 B 1 MARBLE COUNTER TOP MARBLE SUPPLIED BY F.C.INSTALLED BY T.C. CAB -1) MARBLE COUNTER BRONZE METAL TRIM WHITE PLEXI GLASS u, (MP 9-1) BRONZE FINISH 0 LINE OF LIGHTS BEHIND PLEXI 9 "27' 0 36" ALL FRONT PLEXI WILL NEED TO BE INSTALLED BY TGC. 86" BY F.C. INSTALLED BY T.C. 86" 21" IS A STANDARD DIMENSION THIS SIZE WILL VARY BASED ON SIZE OF CASH WRAP 2" 21" 27' j JUNCTION BOX FOR QUAD BOX IN BASE BY F.C. FOR FINAL CONNECTION —} 2 CIRCUITS REQUIRED 1 CIRCUIT - LIGHTING 1 CIRCUIT - REGISTER RECEPTACLES (MB)1 MARBLE SURROUND SUPPLIED (MB)I MARBLE SURROUND SUPPLIED BY F.C. INSTALLED BY T.C. 33" 0 E.C. TO CONNECT LIG THE FIELD TAILS SLO'LIED BY F.C. 3 4 M M (MB -1) CASH REGISTER MARBLE SURROUND TO BE INSTALLED BY TGC.- SCREWS INTO PLACE (MB`) MARBLE COUNTERTOP (FLAT /SQUARE POLISHED EDGE) INTERNALLY ILLUMINATED WHITE FROSTED FRONT AND SIDE OF REGISTER COUNTER ANODIZED BRONZE METAL TRIM AROUND GLOWING WHITE PANELS ACCESS TO LIGHT FIXTURES FROM FRONT FACE OF COUNTER UNE OF LIGHTS BEHIND PLEXI FF -01 C SIDE BY SIDE REGISTER COUNTERS 1/2". WHITE PLEXI GLASS 1• 33" 2 5 THIS END ITE PRIMER ' 12" ( PLOACK BAR SLAB SHELVES -1 ) CAMEO WHITE C❑RIAN (WD -3) MARBLE COUNTERTOP T /SQUARE POLISHED EDGE) io o a N r 2 24" 13" " ZAPEN�i. ARK CHARCOA ON ASH 6 B -I MARBLE LEDGE T /SQUARE POLI D E) 3" 18" OUTLET FOR HEAT GUN SHRINK WRAP BY FIXTUR CONTRACTOR, SHOWS THR OF CABINET OUTLET FOR HEAT GUN A SHRINK WRAP BY FIXTURE CONTRACTOR. SHOWS THRU OF CABINET MARBLE LEDGE (FLAT /SQUARE POLISHED EDGE) 24" 3 4 M N, tT ❑R T ❑R i - FF -07 SELF -TREAT @ REGISTER COUNTER �- 1/2":=V-0" CAMEO WHITE CORIA 6" 7 7 FF -05 BACKBAR SLAB SHELVES 1/2".1'-o- 48" JUNCTION BO ' "IN BA OF CABINET FOR HEAT AND SHRINK WRAP DUPLEX F RCOUNTER REFRIG. BY T.G.C. STALL IN SPLASH IN T FIF BEHIND BOTTLE TRAY 12' 24 LlfsRECEPTACLE FOR REFRIGERAT ❑R COUNTER T ❑P (TS-.) REFRIG. WHITE CORI2 I TRASH 1 tm 6" 144" NEW BACK BAR SLAB SHELF 48" DRAIN. P 177" 8 HOT AND COL WATER FILTER REQUIRED FL❑ ❑R SINK SPLASH GUARDS 23" 29' 11)¢" — - 20' OUTLETS FOR BLENDERS AN HOT POT BY FIXTURE CONT. DARK CHARCOAL WIRED TO JUNCTI ❑N BOX IN BASE ON ASH INDIVIDUAL CIRCUITS 1 B OTTLE TR»Y 23' STAINLESS PREP. SINK WITH RED RINSER, 62' 62' LOOSE 4' STEP /2' GALLON WATER BOTTLE 177" W LA GE =:IN 7;'4 isi�5 r•;ydr I 48" STORAG LL SMALL CUSTOM 29" ❑TTLE HOLDER (STEP UP) STRAWS ' BLENDERS HOT LIDS 29" POT STARLESS STEEL MR SITS MI COUNTER 1U OPEN END MARBLE COUNTER TOP ,1B --1) MARBLE OUNTER TOP HOT POT BI UP DI NAPKINS 10" a DOB bll DARK CHARCOAL ON QUARTERED ASH INTERNALLY ILLUMINATE SURFACE OF COUNTER 9 ics QVD- I DARK CHARCOAL ON QUARTERED ASH WD -3) DARK CHARCOAL ON QUARTERED ASH BRONZE FINISH 3) -3 "X10" VENTS WDERCOATED BRONZE JUNCTION BOX IN BASE BY F.0 FOR FINAL CONNECTION_ STAINLESS HAND ¢ SINK FF -04B RIGHT HAND BACK BAR/CUSTOMIZATION COUNTER 1/2W-0" FF -02 3 TIER SELF - CONSUMPTION CASE �— 1/2 =1 ' -0 " P DISPENSER GLASS SIDES MARBLE `. COUNTER TO VD DAR CHARCOAL ON QUARTERE ASH GLASS SIDES 1 @D- �B� MARBLE COUNTER T 1' j DARK CHARCOAL ON QUARTE II. ASH E`d WWI° CODE COMPLIANCE APPROVED FEB 1 ) 2603 35" 35' CiW Of TukWii ° BUILDING ! s FEB — 8 2008 PERMIT CENTt FIXTURE DETAILS F -1.2 ISSUED I REVISED DATE HEALTH DEPT SUBMITTAL 12.17.07 98% OWNER REVIEW HEALTH DEPT RVSNS ISSUED FOR PERMIT 01.03.08 01.11.08 01.25.08 4 5 6 7 8 9 10 1- 1 /4"CW 1 /2"HW 3/4 "C4 -13 T &P AND PAN TO DISCHARGE JANITORS SINK P2.0 FEQ 09 TYP .CEQ - SALES AREA DOMESTIC WATER PLAN SCALE: 1 /4 "= 1'--0" 3 /4 "ACD 3 "W_ 2"V 'NTROL V LVE f > > SALES AREA 3 WASTE AND VENT PLAN SCALE 1 /4 " = 1' -0" 0 • � 1 1 1 REMOTE STOCKROOM PLAN SCALE: 1 /4 " =1' -0" WASTE AND VENT RISER DIAGRAM NOT TO SCALE FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT AND /OR ENGINEER VIA OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT AND /OR ENGINEER VIA OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTOR'S COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES. THE PLANS AND SPECIFICATIONS NOT WITHSTANDING, THE CONTRACTOR SHALL ALERT ARCHITECT AND /OR ENGINEER VIA OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. * FIXTURES /EQUIPMENT SCHEDULED AND LOCATIONS SHOWN ON PLANS ARE SUBJECT TO BUILDING DEPARTMENT AND HEALTH DEPARTMENT APPROVAL EQ -141 po 011 EQ -18 U N P20 1 EQ -o9 PLUMBING PLAN NOTES: C 1 DO NOT INSTALL PLUMBING PIPING OVER ELECTRICAL PANELS. 0 0 10 11 I EQ -191 DOMESTIC NOT TO SCALE CONNECT NEW 3" VENT TO EXISTING 3" VENT. COORDINATE EXACT TIE IN LOCATION AND ROUTING PRIOR TO START OF INSTALLATION. INSTALL FULL UNE SIZE INDIRECT DRAIN FROM SINK AND TERMINATE INDIRECT AT FLOOR SINK WITH AIR GAP PER CODE. CONNECT 1" COLD WATER FOR NEW SALES COUNTER EQUIPMENT TO EXISTING 4" COLD WATER MAIN AND PROVIDE A NEW TENANT DOMESTIC WATER SUBMETER. COORDINATE EXACT TIE IN LOCATIONS AND ROUTING PRIOR TO START OF INSTALLATION. CONNECT NEW 4" SANITARY LINE INTO EXISTING 4" SANITARY UNE. FIELD VERIFY THE EXACT LOCATION AND INVERT ELEVATION FOR NEW SANITARY LINE CONNECTION POINT PRIOR TO INSTALLATION. IF FOUND THAT NEW CONNECTION POINT CAN NOT BE MADE, NOTIFY ARCHITECT AS SOON AS POSSIBLE FOR ISSUE TO BE RESOLVED NOT TO DELAY CONSTRUCTION SCHEDULE. WATER FILTER IS FURNISHED BY THE EQUIPMENT SUPPLIER AND INSTALLED BY THE PLUMBING CONTRACTOR. CONDENSATE LINE TO RUN TO LOW LEVEL IN WALL AND THEN OUT TO CONNECT DIRECTLY TO TAILPIECE OF HAND SINK. AUXILLIARY CONDENSATE LINE TO RUN TO LOW LEVEL IN WALL THEN OUT TO DISCHARGE INTO FLOOR SINK WITH AIR GAP PER CODE. CONDENSATE LINE FROM VENTROL UNIT TO RUN BELOW CEILING THEN DOWN WALL TO LOW LEVEL AND DISCHARGE INTO MOP SINK WITH AIR GAP PER CODE. EXISTING 3- COMPARTMENT SINK TO BE REMOVED AND RELOCATED TO NEW SALES AREA. EXISTING HAND SINK TO REMAIN. 3 /4 "HW 3 /4 "CW [ -11 P2.0 3 /4 "HW 3 /4 "CW 1"CW 3 /4 "CW P2.0 C EQ -10 Q-27A) IEQ -131 0-12B 3 /4 "HW 3 /4 "CW TYP. 1 /2 "HW 1 /2 "CW 1EQ -14 WATER RISER DIAGRAM Y RECEIEr 94 .4 FEB - 8 2008 PERMIT CENT& HENDERSON ENGINEERS= 10370 RICHMOND AVENUE, SUFTE 370 HOUSTON, TX 77042 TEL 713 783 7707 FAX 713 783 7797 www.hei- eng.com 0750001294 RJS JMH SLM TYP. ISSUED/REVISED HEALTH DEPT SUBMITTAL 98% OWNER REVIEW HEALTH DEPT RVSNS ISSUED FOR PERMIT 11/07/08 s; D l CO) V CD PLUMBING FLOOR PLAN P -1.0 DATE 12.17.07 01.03.08 01.11.08 01.25.08 FIRE PROTECT. SYMBOLS I NOTE: TNHIS ECES IS A MASTER SARILY USED LEGEND ON THE AND NOT DRAWINGS. ALL SYMBOLS, ETC. ARE FIRE SPRINKLERS O UPRIGHT SPRINKLER 0 PENDENT SPRINKLER A CONCEALED SPRINKLER SPRINKLER DRY PENDENT V DRY SIDEWALL SPRINKLER • SIDEWALL SPRINKLER PIPING FP FIRE PROTECTION (FP) oa SHUTOFF VALVE NJ CHECK VALVE BACK FLOW PREVENTER CAP -o ELBOW UP T ELBOW DOWN �a TEE UP ��� TEE DOWN < FIRE DEPARTMENT CONNECTION ______e_it FIRE PUMP TEST HEADER 3.---+ INSPECTOR'S TEST CONNECTION / AUXILIARY DRAIN i SPRINKLER RISER / TOP BEAM CLAMP / / / TRAPEZE HANGER ANNOTATION 0 FIRE PROTECTION PLAN CALLOUT V CONNECTION POINT OF NEW WORK TO EXISTING AI DETAIL REFERENCE UPPER NUMBER INDICATES DETAIL NUMBER w LOWER NUMBER INDICATES SHEET NUMBER SECTION CUT DESIGNATION ABBREVIATIONS AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE CD CANDELA DI DUCTILE IRON ESFR EARLY SUPPRESSION FAST RESPONSE ETR EXISTING TO REMAIN FHC FIRE HOSE CABINET FP FIRE PROTECTION GC GENERAL CONTRACTOR GPM GALLONS PER MINUTE JB JUNCTION BOX MAX MAXIMUM MIN MINIMUM N/A NOT APPLICABLE NIC NOT IN CONTRACT OC ON CENTER PIV POST INDICATOR VALVE PROVIDE FURNISH AND INSTALL PRV PRESSURE REDUCING VALVE RD RETURN DUCT REV REVISION SD SUPPLY DUCT SF SQUARE FEET TYP TYPICAL UL UNDERWRITERS LABORATORIES, INC. UNO UNLESS NOTED OTHERWISE V VOLT(S) WP WEATHERPROOF 1 2 3 4 6 7 8 9 10 F- REMOTE STOCKROOM FIRE SPRINKLER PLAN SCALE: 1 /4" =1' --0" FIRE SPRINKLER GENERAL NOTES: 1. SPRINKLER SYSTEM DESIGN, INSTALLATION AND MATERIALS SHALL BE IN ACCORDANCE WITH NFPA 13. SYSTEM SHALL ALSO MEET ALL APPLICABLE BUILDING CODES, FIRE CODES AND THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION AND INSURANCE CARRIER. VERIFY REQUIREMENTS PRIOR TO BID SUBMITTAL. 2. INFORMATION ON CONTRACT DOCUMENTS IS GENERAL INFORMATION AND FOR BID PURPOSES ONLY. LAYOUT SYSTEM, PERFORM REQUIRED CALCULATIONS AND COORDINATE WITH OTHER TRADES. 3. PROVIDE ADDITIONAL MATERIALS AND LABOR REQUIRED DUE TO LACK OF COORDINATION AND TO MEET AUTHORITY HAVING JURISDICTION AND INSURANCE CARRIER REQUIREMENTS AT NO ADDITIONAL COST TO THE OWNER. 4. PROVIDE MINIMUM ORDINARY HAZARD GROUP 2 DESIGN CRITERIA (0.20 GPM /SF OVER 1500 SF HYDRAULIC REMOTE AREA) THROUGHOUT BUILDING UNLESS REQUIRED OTHERWISE. INCLUDE HOSE ALLOWANCE AT BASE OF RISER. 5. PROVIDE MINIMUM ORDINARY HAZARD GROUP 2 DESIGN CRITERIA (0.20 GPM /SF OVER 1500 SF HYDRAULIC REMOTE AREA OR ENTIRE AREA, WHICH EVER IS SMALLER) THROUGHOUT MECHANICAL AND STORAGE AREAS. INCLUDE HOSE ALLOWANCE AT BASE OF RISER. 6. COORDINATE PIPE ROUTING NEAR ELECTRICAL EQUIPMENT WITH NFPA 70. 7. COORDINATE SPRINKLER TEMPERATURES NEAR HEAT - PRODUCING SOURCES WITH NFPA 13. 8. FORWARD COMPLETED CONTRACTOR MATERIAL TEST CERTIFICATES TO THE OWNER. 9. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. SALES AREA C FIRE 1 S/4 " PRI1' NKLER " PLAN SCALE: =-0 FIRE SPRINKLER PLAN NOTES: EXISTING TENANT POINT OF CONNECTION TO LANDLORD SYSTEM TO REMAIN. PROVIDE INDICATING CONTROL VALVE FOR TENANT SPACE. CONNECT TO EXISTING LANDLORD PROVIDED SPRINKLER MAIN. INSTALL WATERFLOW AND VALVE TAMPER SUPERVISORY SWITCH. COORIDINATE MONITORING OF EQUIPMENT WITH LANDLORD'S FIRE ALARM CONTROL PANEL WITH FIRE ALARM CONTRACTOR. EXISTING REMOTE STOCK ROOM. NO FIRE SPRINKLER WORK TO BE PERFORMED TO EXISTING SPACE. o,erri FEB -8 2008 PERMIT CENTEh HENDERSON ENGINEERS= 10370 RICHMOND AVENUE, SUITE 370 HOUSTON, TX 77042 TEL 713 783 7707 FAX 713 783 7797 www.hei- eng.cem 0750001294 R151MH 5LM Q gig O Z LU 0 E MCP. /, `V C:) N 0 U 0 0) ISSUED / REVISED DATE HEALTH DEPT SUBMITTAL 12.17.07 98% OWNER REVIEW 01.03.08 HEALTH DEPT RVSNS 01.11.08 ISSUED FOR PERMIT 01.25.08 FIRE SPRINKLER FLOOR PLAN P -1.1 1 2 4 6 8 9 10 COLD WATER SUPPLY CONCEALED IN PARTITION. BACKFLOW PREVENTER WITH UPSTREAM STRAINER IF /AS REQUIRED BY LOCAL AUTHORITIES CONNECT TO CONDENSATE DRAIN AND DRAIN PAN OUTLETS ON CUBER REFER TO "INDIRECT DRAIN INSTALLATION" DETAIL FOR MORE INFORMATION HOT WATER TO FIXTURES AS SHOWN ON PLANS CHECK VALVE SHUTOFF VALVE (TYPICAL) PROVIDE PIPE UNION, DIELECTRIC IF REQUIRED FOR DISSIMILAR METALS (TYPICAL) ELECTRIC WATER HEATER. REFER TO SPECIFICATIONS AND SCHEDULE SET WATER HEATER ON STEEL PLATE PLATFORM (PLATFORM IS BY GENERAL CONTRACTOR) DRAIN VALVE BY WATER HEATER MANUFACTURER MINIMUM 1" FOR BLOW -THRU MECHANICAL UNIT; MINIMUM 1" PLUS NEGATIVE STATIC PRESSURE IN INCHES WATER COLUMN FOR DRAW THRU UNIT REFER TO FLOOR PLANS FOR SIZE AND EXACT ROUTE OF CONDENSATE AND AUXILIARY CONDENSATE DRAINS. RE: SPECIFICATIONS FOR PIPE MATERIAL AND INSULATION REQUIREMENTS PROVIDE TRAP DEPTH GREATER THAN 4" OR 1/2" PLUS STATIC PRESSURE IN INCHES WATER COLUMN PIPING ARRANGEMENT SHOWN FIELD CONDITIONS AND MEET INSTALLATION INSTRUCTIONS. DRAIN CONNECTIONS IF DUAL CUBER PROVIDE 6" HIGH VENT PIPE, OPEN TO THE ATMOSPHERE WHERE REQUIRED BY CODE FOR LENGTH OF DRAIN PIPE ICE BIN • • WATER HAMMER ARRESTER, PDI SIZE WHEEL - HANDLE ANGLE STOP VALVE PER SPECIFICATIONS ADAPTERS AND SIX FOOT LENGTH OF COILED SOFT COPPER TUBING WITHOUT KINKS, SIZE OF CUBER WATER INLET. CONNECT FROM SHUT -OFF VALVE TO CUBER WATER INLET. 1 { FLOOR SINK WHERE '.ice SHOWN ON FLOOR PLANS. IS SCHEMATIC. ADJUST TO SUIT EQUIPMENT MANUFACTURER'S PROVIDE DUPLICATE WATER AND CUBERS ARE FURNISHED. AIR COOLED ICE MACHINE NOT TO SCALE ACD 6" TALL VENT OPEN TO ATMOSPHERE CONNECT TO ICE BIN DRAIN OUTLET. DO NOT COMBINE WITH CUBER DRAIN PIPE. COLD WATER SUPPLY TO WATER HEATER COLD WATER TO EXPANSION TANK AS SHOWN ON PLANS AUTOMATIC VACUUM RELIEF VALVE (WHEN REQUIRED) INSTALL ASME TEMPERATURE AND PRESSURE RELIEF VALVE FURNISHED WITH WATER HEATER PROVIDE A HARD COPPER RELIEF VALVE DISCHARGE LINE FULL SIZE OF VALVE OUTLET 6" WATERTIGHT PAN UNDER HEATER WITH DRAIN PIPE ROUTE RELIEF VALVE DISCHARGE LINE AND DRAIN PAN LINE DOWN CONCEALED IN WALL THE OUT TO DISCHARGE INTO JANITORS SINK WITH AIR PER CODE REFER TO SPECIFICATIONS, SCHEDULES AND NOTES FOR MORE INFORMATION. PIPING ARRANGEMENT SHOWN IS SCHEMATIC. VERIFY ALL CONNECTION SIZES AND LOCATIONS PER MANUFACTURERS REQUIREMENTS. ADJUST TO SUIT FIELD CONDITIONS. REFER TO FLOOR PLANS FOR PIPE SIZES. PROVIDE SEISMIC STRAP OR BRACING IF /AS REQUIRED BY LOCAL AUTHORITIES. PROVIDE HEAT TRAP AND AUTOMATIC VACUUM RELIEF VALVE WHEN REQUIRED BY LOCAL AUTHORITIES. SHELF MOUNTED WATER HEATER NOT TO SCALE TEE WITH CLEANOUT PLUG (TYPICAL) PROVIDE INCREASER TO MINIMUM ONE PIPE SIZE LARGER THAN UNIT CONNECTION, MINIMUM 3/4" MECHANICAL EQUIPMENT RE: MECHANICAL DRAWINGS DRAIN PAN SUSPENDED BELOW UNIT. RE: MECHANICAL DRAWINGS PROVIDE FLEXIBLE ADAPTER COUPLING FOR ATTACHMENT TO A MOTORIZED UNIT. OTHERWISE, PROVIDE A UNION. TEE WITH CLEANOUT PLUG PIPING ARRANGEMENT SHOWN IS SCHEMATIC: ADJUST AS REQUIRED TO SUIT ACTUAL INSTALLATION CONDITIONS. REFER TO LOCAL CODE FOR INDIRECT DRAIN REQUIREMENTS C AIR HANDLING UNIT CONDENSATE DRAIN NOT TO SCALE 3/4" PIPE FROM COLD WATER SUPPLY TO WATER HEATER, WITH NO CHECK VALVES INTERVENING FDA - COMPLIANT BUTYL DIAPHRAGM WELDED STEEL EXPANSION TANK WITH POLYPROPYLENE LINING, NSF APROVED FOR DOMESTIC WATER SERVICE PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. FOLLOW MANUFACTURER'S INSTRUCTIONS FOR INSTALLATION PROCEDURE. VERIFY PROPER OPERATION WHEN INSTALLED. PROVIDE SEISMIC STRAP OR BRACING WHEN REQUIRED BY LOCAL AUTHORITIES. COLD WATER MAIN BRANCH PIPE WITH SHUT -OFF VALVE FEEDING PLUMBING FIXTURE(S) AUTOMATIC TRAP PRIMER VALVE WITH INTEGRAL AIR GAP. INSTALL TRAP PRIMER MINIMUM 12" ABOVE FLOOR FOR EVERY 20' OF PRIMER DISCHARGE PIPE. PROVIDE DISTRIBUTION UNIT(S) WHERE MORE THAN ONE TRAP IS SERVED BY ONE TRAP PRIMER VALVE. IF TRAP PRIMER IS INSTALLED ABOVE HARD CEILING, PROVIDE ACCESS DOOR PER SPECIFICATIONS. PROVIDE FLOOR DRAIN BODY OR P -TRAP WITH THREADED TRAP PRIMER CONNECTION. PROVIDE SWEAT TO THREADED ADAPTER. BRAZE JOINT BELOW FLOOR SLAB ON GRADE. 3 SMALL OT TO SC EXPANSION TANK N I' . PROVIDE TRAP PRIMERS WHERE SHOWN ON FLOOR PLANS, AND WHERE BY LOCAL AUTHORITIES. PIPING ARRANGEMENT SHOWN IS SCHEMATIC: TO SUIT FIELD CONDITIONS. REFER TO SPECIFICATIONS AND PLUMBING SCHEDULE FOR MORE INFORMATION. INSTALL TRAP PRIMER VALVE AND DISTRIBUTION UNIT PER MANUFACTURER'S RECOMMENDATIONS. TRAP PRIMER OVERHEAD NOT TO SCALE PROVIDE CLEAN OUTS IN TURNS AND ENDS OF DRAIN PIPE FLOOR SLAB i PIPE HANGER NEXT i j �� TO ELBOW _ PROVIDE DIELECTRIC PIPE UNION AT TANK CONNECTION FOR CONNECTION OF DISSIMILAR METALS 71 r INSTALL FLOW CONTROL FITTING FURNISHED WITH GREASE TRAP GREASE INTERCEPTOR REFERENCE SPECIFICATIONS AND SCHEDULES. SET ON FLOOR WHERE TOP CAN BE EASILY REMOVED FOR CLEANING. AIR CHARGING VALVE. FILL TANK WITH AIR PRESSURE TO MATCH WATER PRESSURE. CONNECT 1/2" PIPE (WITHOUT SHUT -OFF VALVE IN BRANCH) TO TRAP PRIMER VALVE OFF TOP OF BRANCH PIPE. INSULATE PIPE UPSTREAM OF TRAP PRIMER, BUT NOT DOWNSTREAM. INSTALL TRAP PRIMER LINE(S) DOWNSTREAM OF TRAP PRIMER OR DISTRIBUTION UNIT USING 1/2" SOFT COPPER TUBING. INSTALL WITHOUT KINKS, AND SLOPE CONTINUOUSLY TOWARDS FLOOR DRAIN. � - CONCEAL PIPE(S) IN PARTITION OR CHASE IN FINISHED AREAS. TRAP PRIMER AND PIPES MAY BE INSTALLED EXPOSED IN UNFINISHED, NON- PUBLIC AREAS. IF PIPE IS BELOW FLOOR SLAB ON GRADE, PROVIDE 1/2" ELASTOMERIC INSULATION FROM PRIMER CONNECTION TO 1" ABOVE FLOOR SLAB. -V REQUIRED ADJUST FIXTURE ■ I I I I .. UTILITY SINK AND GREASE TRAP NOT TO SCALE GENERAL NOTES: 1. DRAWINGS ARE DIAGRAMMATIC ONLY AND REPRESENT THE GENERAL SCOPE OF THE WORK. PRIOR TO SUBMITTING BID, VISIT THE JOB SITE TO OBSERVE THE EXISTING CONDITIONS OF THE PROJECT. REVIEW THE GENERAL NOTES, SPECIFICATIONS AND PLANS FOR ADDITIONAL REQUIREMENTS THAT MAY NOT BE SPECIFICALLY CALLED OUT IN THIS PORTION OF THE CONSTRUCTION DOCUMENTS. NOTIFY OWNER'S CONSTRUCTION MANAGER OF ANY CONFLICTS OR DISCREPANCIES PRIOR TO SUBMISSION OF BID. 2. FURNISH A CONSTRUCTION RECORD SET OF "AS- BUILT" DOCUMENTS TO THE OWNER'S CONSTRUCTION MANAGER REFLECTING ANY VARIANCES OF INSTALLED PIPING LOCATIONS OR EQUIPMENT AFTER FINAL INSPECTION OF INSTALLED PLUMBING SYSTEMS. 3. FURNISH TO THE OWNER'S CONSTRUCTION MANAGER A COPY OF INSPECTION REPORTS AND APPROVAL CERTIFICATES FROM LOCAL AND STATE INSPECTIONS. INSTALLATION SHALL COMPLY WITH LEGALLY CONSTITUTED CODES AND THE REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION AND ALSO MEET ALL REQUIREMENTS OF THE LANDLORD. 5. PLANS AND SPECIFICATIONS GOVERN WHERE THEY EXCEED CODE REQUIREMENTS. 6. REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION AND MOUNTING HEIGHTS OF PLUMBING FIXTURES. 7. DO NOT SCALE FLOOR PLANS FOR EXACT HORIZONTAL LOCATION OF PIPE ROUTING. 8. PIPING IN FINISHED AREAS SHALL BE ROUTED CONCEALED; EXPOSED PIPING, WHERE NECESSARY, SHALL BE ROUTED AS HIGH AS POSSIBLE AND TIGHT TO WALLS. 9. COORDINATE PIPING INSTALLATION WITH STRUCTURAL GRADE BEAMS, FOOTINGS, COLUMN PIERS, ETC. SLEEVE PIPING THROUGH GRADE BEAMS, FOOTING, ETC. WHERE REQUIRED AND AS NOTED ON PLANS. COORDINATE SLEEVE INSTALLATIONS WITH THE ARCHITECT, STRUCTURAL ENGINEER, STRUCTURAL CONTRACTOR AND GENERAL CONTRACTOR BEFORE CONCRETE IS INSTALLED. 10. CLEAN FAUCET AERATORS AND PIPE STRAINERS PRIOR TO TURNING BUILDING OVER TO THE OWNER. 11. COORDINATE PIPE ROUTING AWAY FROM ELECTRICAL PANELS. DO NOT ROU I E PIPING OVER ELECTRICAL PANELS. 12. COORDINATE ALL ROOF PENETRATIONS WITH OTHER TRADES. MAINTAIN 10' MINIMUM CLEARANCE FROM ALL AIR INTAKES. MAINTAIN 2' CLEARANCE FROM ALL OTHER EQUIPMENT. 13. WATER HAMMER ARRESTORS SHALL BE SIZE "A" UNLESS NOTED OTHERWISE. 14. CONTRACTOR SHALL PROVIDE AND PAY ALL FEES AND PERMITS. 15. ALL INDIRECT DRAIN PIPING INTO FLOOR SINKS MUST MAINTAIN A MINIMUM 2" AIR GAP. 16. VERIFY EXACT CONNECTION LOCATIONS OF EXISTING WATER AND SANITARY PIPING IN THE FIELD PRIOR TO BID. 17. PROVIDE NEW LINE SIZED SHUT -OFF VALVES TO ALL EQUIPMENT. 18. COORDINATE ALL ROOF WORK WITH THE CONTRACTOR LISTED ON THE WARRANTY. 19. PROVIDE ALL REQUIRED BACKFLOW PREVENTION. 20. EXISTING LANDLORD PROVIDED 3 /4 "CW CONNECTION TO BE ABANDONED. MAKE NEW 1" COLD WATER CONNECTION TO EXISTING 4 "CW MAIN. INCREASED CONNECTION SIZE TO BE PROVIDED BY TENANT AND COORDINATED WITH TENANT COORDINATOR. 21. ALL TENANTS REQUIRING BELOW GRADE WORK SHALL COORDINATE WITH LANDLORD PRIOR TO ANY SLAB DEMOLITION. TENANT SHALL BE ROSPONSIBLE FOR RECONSTRUCTION AND PATCHING OF THE SLAB ON GRADE SYSTEM. .4 2" VENT RISER T CONCEALED IN WALL 1- --1/2" AIR INTAKE ON FLOW CONTROL VALVE 1 -1/2" VENT ON TRAP CONCEALED IN WALL CLEANOUT SHUTOFF VALVE \_ 3" WASTE ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS OR MEET LOCAL CODE REQUIREMENTS. CONNECT TRAP FROM CENTER COMPARTMENT. EQUIPMENT FURNISHED BY GODIVA: EQ -031 EQ -09 1 1EQ -11 IEQ -12A 0-12E EQ -131 EQ -141 1EQ - 1EQ -191 BLENDTEC RED RINSER: 6"W x 6 "D x 2 5/8 "H FOOTPRINT, 2.23 GPM FLOW RATE. ICE MACHINE: HOSHIZAKI MOD. KM151BAH AIR COOLED, UNDER - COUNTER, STAINLESS STEEL, SELF-CONTAINED CUBER WITH BUILT IN STORAGE. PREP SINK: EAGLE GROUP MODEL #414 -16 -3--18 19" X 16" 3- COMPARTMENT SINK WITH DUAL DRAINBOARDS. FAUCET: DELTA FAUCET #2476/H24/A24. NOTE: TO BE PROVIDED BY THE TENANT AND INSTALLED BY THE GENERAL CONTRACTOR. SEE EQ -11 ON FIXTURE SHEET F -1.0. SINK: EAGLE GROUP MODEL FDI- 16- 19- 13 -5 -1 FAUCET: DELTA 2476 -H24 COLOR: WHITE SPRAYER: SUPPLIED WITH FAUCET. NOTE: TO BE PROVIDED BY THE TENANT AND INSTALLED BY THE GENERAL CONTRACTOR. SEE EQ -12B ON FIXTURE SHEET F -1.0. SINK: EAGLE GROUP MODEL FDI- 10- 14 -5 -1 FAUCET: DELTA 2476-H24 COLOR: WHITE SOAP DISPENSER: DELTA FAUCET #RP1001. NOTE: TO BE PROVIDED BY THE TENANT AND INSTALLED BY THE GENERAL CONTRACTOR. SEE EQ -12B ON FIXTURE SHEET F -1.0. LAVATORY: AMERICAN STANDARD "LUCERNE" #0355.012, FAUCET: CHICAGO #802A, 4" CENTERS, FLAT PLATE STRAINER, CAST BRASS TRAP WITH CLEANOUT, STOPS, SUPPLIES, CONCEALED ARM SUPPORT, OFFSET TAILPIECE, & PROTECTIVE COVERING LIKE SEALGAURD, MOUNT @ 34" A.F.F. TO RIM TO MEET ADA. SEE EQ -13 0 FIXTURE SHEET F1.0. WATER CLOSET: "AMERICAN STANDARD" ELONGATED CADET #2998.012, WHITE, SEAT: OLSONITE #47, WHITE, VITREOUS CHINA, FLOOR MOUNTED, SIPHON JET, TANK TYPE, ELONGATED BOWL, OPEN FRONT SEAT, HANDLE ON WIDE SIDE OF STALL. SEE EQ -14 ON FIXTUR SHEET F1.0. HAND SINK: EAGLE GROUP MODEL #HSAN -10 -F 18" X 12" X 6 3/4" DEEP BOWL. FAUCET: DELTA FAUCET #2476/H24/A24. SOAP DISPENSER: DELTA FAUCET #RP1001. NOTE: TO BE PROVIDED BY THE TENANT AND INSTALLED BY THE GENERAL CONTRACTOR. SEE EQ -18 ON FIXTURE SHEET F -1.0. PREP SINK: EAGLE GROUP MODEL #414-16-1-18 R OR L 19" X 16" SINGLE COMPARTMENT SINK WITH SINGLE DRAINBOARD. FAUCET: DELTA FAUCET #2476/H24/A24. NOTE: TO BE PROVIDED BY THE TENANT AND INSTALLED BY THE GENERAL CONTRACTOR. SEE EQ -19 ON FIXTURE SHEET F -1.0. EQUIPMENT PROVIDED BY CONTRACTOR: CEQ -10) MOP SINK: "FIAT" MODEL #MSB2424, PROVIDE WITH MOP HANGER AND SERVICE SINK FAUCET 830AA. SEE EQ -10 ON FIXTURE SHEET F1.0. CEQ -21) FLOOR SINK: JOSAM # 49300-LF-NB, 6" DEEP CAST IRON BODY WITH ACID RESISTING ENAMELED INTERIOR, LESS FLANGE, ALUMINUM SEDIMENT BUCKET, AND 8" SQUARE NICKEL BRONZE GRATE. USE CAULK JOINT OF OUTLET SIZE AS SHOWN ON PLANS. CEQ -23) WALL CLEANOUT: JAY R. SMITH # 4530S, CAST IRON CLEANOUT TEE, COUNTER SUNK PLUG, STAINLESS STEEL ROUND COVER AND SCREW, AND IRON PLUG WITH GASKET SEAL. REFER TO SPECIFICATIONS FOR INSTALLATION. (EQ -24) WATER HAMMER ARRESTER: PRECISION PLUMBING PRODUCTS, HARD DRAWN COPPER BODY WITH WROUGHT COPPER FITTINGS, PISTON TYPE WITH LUBRICATED EPDM "0" RING SEALS, ASSE 1010 CERTIFICATION. PROVIDE PDI SIZES "A" THROUGH "F" AS SHOWN ON PLANS. PROVIDE SIZE "A" UNLESS SHOWN OTHERWISE ON THE PLANS. (EQ -26) GREASE TRAP: ZURN #GT- 2700 -20, WELDED STEEL TRAP. ACID RESISTANT ENAMEL COATED INTERIOR, SEMI AUTOMATIC GREASE DRAW OFF, LINE SHUT OFF VALVE, FLOW CONTROL FIlIING AND FLOW RATE OF 20 GPM AND A 40 POUND GREASE CAPACITY. CEQ -27A) WATER HEATER: A. 0. SMITH # DEL -50, 50 GALLON GLASS LINED LOW BOY STORAGE TANK, TWO 5KW DIRECT - IMMERSION HEATING ELEMENTS FOR SIMULTANEOUS OPERATION, SURFACE - MOUNTED THERMOSTATS, ANODE ROD, T & P VALVE, AND 68 GALLONS PER HOUR RECOVERY AT A 60 DEGREE TEMPERATURE RISE. SET WATER HEATER OPERATING TEMPERATURE TO 120 'F. ELECTRICAL REQUIREMENTS: 208 VOLT THREE PHASE UNBLANCED CIRCUIT, L2 = 41.6 FULL LOAD AMPS, L1 & L3 = 24.0 FULL LOAD APMPS. (EQ -28) FLOOR CLEANOUT: JAY R. SMITH, CAST IRON BODY, FLASHING FLANGE WITH CLAMPING COLLAR, ABS PLUG, AND ADJUSTABLE, ROUND, SECURED, NICKEL BRONZE, TOP. # 4151 ( -F -C), 1/8" RECESS FOR INSTALLATION IN TILED FLOOR AREA(S). CEQ -29) TRAP PRIMER: PRECISION PLUMBING PRODUCTS # PR -500 "PRIME- RITE ", CORROSION RESISTANT BRASS BODY, "0" RING SEALS, 1/2" INLET AND OUTLET, AND INTEGRAL VACUUM BREAKER. INSTALL THE VALVE AT A MINIMUM OF 12" ABOVE FINISHED FLOOR. PROVIDE WITH DISTRIBUTION # DU -2 FOR TWO, # DU-3 FOR THREE, OR #DU -4 FOR FOUR CONNECTIONS. ( -30) EXPANSION TANK: AMTROL "THERM -X -TROL" #ST -5, WELDED STEEL PRESSURE TANK, POLYPROPYLENE LINING, FLEXIBLE BUTYL DIAPHRAGM, AIR CHARGING VALVE, 150 PSI MAXIMUM WORKING PRESSURE, 2.0 GALLON CAPACITY, 0.45 MAXIMUM ACCEPTANCE FACTOR, 3/4" PIPE CONNECTION. SET THE AIR CHARGE PRESSURE TO MATCH EXISTING WATER SYSTEM PRESSURE. E07 WATER METER: AMCO #C700 1 ", BRONZE MAINCASE AND MEASURING CHAMBER, BRONZE BOTTOM PLATE, STAINLESS STEEL TRIM AND BOLTS, THERMOPLASTIC STRAINER, OSCILLATING PISTON MEASURING ELEMENT, STRAIGHT READING HERMETICALLY SEALED REGISTER, REGISTRATION IN U.S. GALLONS, MAGNETIC DRIVE, AND COMPLIANCE WITH ANSI /AWWA C700. PROVIDE WITH REMOTE READING SYSTEM IF /AS REQUIRED. (EQ -32) FLOOR DRAIN: JAY R. SMITH # 2005L ( -A), CAST IRON BODY AND CLAMPING COLLAR, ADJUSTABLE 6" ROUND NICKEL BRONZE STRAINER. USE PUSH ON JOINT OF OUTLET SIZE AS SHOWN ON PLANS. EQ -2 REDUCED PRESSURE ZONE BACKFLOW PREVENTER: WATTS # 009QT -S, CAST BRONZE BODY, QUARTER TURN TEST COCKS, QUARTER TURN BALL VALVES, BRONZE STRAINER, AND # 909AG AIR GAP FITTING. PLUMBING LEGEND: �T - S -. -VBG --4 ;V-- -S �S S S - -S S W i S- -W S S GW -- - 5 S-- GW ---SS SCD S S- - - ID - - S 5- G - S S -G- -S S I 1 S S S I " S � S 9 Q II S L S n S c. 7 0 1 AFF BFF DN ETR IE VTR DOMESTIC COLD WATER (CW) DOMESTIC HOT WATER (HW) HOT WATER RECIRCULATION (HWR) TRAP PRIMER LINE (T) PLUMBING VENT BELOW GRADE (VBG) PLUMBING VENT ABOVE FLOOR (V) SANITARY PIPING ABOVE FLOOR (S) SANITARY PIPING BELOW FLOOR (5) WASTE PIPING ABOVE FLOOR (W) WASTE PIPING BELOW FLOOR (W) GREASE WASTE ABOVE FLOOR (GW) GREASE WASTE BELOW FLOOR (GW) CONDENSATE DRAIN (CD) INDIRECT DRAIN (ID) NATURAL GAS BELOW ROOF (G) NATURAL GAS ABOVE ROOF (G) ELBOW UP & ELBOW DOWN IN PIPING TEE UP & TEE DOWN IN PIPING ELBOW UP & ELBOW DOWN IN PIPING WITH SHUTOFF VALVE (SOV) BALL VALVE CHECK VALVE STRAINER RECIRCULATION PUMP RELIEF /SAFETY VALVE WATER HAMMER ARRESTER WITH PDI SIZES: A, B, C, D, AND E PRESSURE GAUGE THERMOMETER UNION TRAP PRIMER TRAP PRIMER WITH DISTRIBUTION UNIT MANUAL / AUTOMATIC AIR VENT OR VACUUM RELIEF VALVE DIRECTION OF FLOW CAP CLEANOUT (CO) WALL CLEANOUT (WCO) FLOOR CLEANOUT (FCO) FLOOR DRAIN (FD) SIZE & TYPE FLOOR SINK (FS) SIZE & TYPE ISOMETRIC FLOOR PENETRATION CONNECT TO EXISTING PLUMBING PLAN NOTE CALLOUT PLUMBING EQUIPMENT DESIGNATION (CONTRACTOR FURNISHED AND INSTALLED) REFER TO PLUMBING FIXTURE OR EQUIPMENT SCHEDULES EQUIPMENT DESIGNATION (OWNER FURNISHED, CONTRACTOR INSTALLED) MECHANICAL EQUIPMENT DESIGNATION (CONTRACTOR FURNISHED AND INSTALLED UNLESS NOTED OTHERWISE) DETAIL REFERENCE ABOVE FINISHED FLOOR BELOW FINISHED FLOOR DOWN EXISTING TO REMAIN INVERT ELEVATION VENT THRU ROOF RECE VE l % FEB - 8 2008 PERMIT CENTEF HENDERSON ENGINEERS= 10370 RICHMOND AVENUE, SUITE 370 HOUSTON, TX 77042 TEL 713 783 7707 FAX 713 783 7797 www.hei eng.com 0750001294 RJS JMH SLM EXP. 11/07/p ® - tte P -2.0 L. 00 c co O Q w O L O LO PLUMBING DETAILS ISSUED I REVISED DATE HEALTH DEPT SUBMITTAL 12.17.07 98% OWNER REVIEW 01.03.08 HEALTH DEPT RVSNS 01.11.08 ISSUED FOR PERMIT 01.25.08 1 2 3 4 5 6 7 8 9 10 SECTION 15B: PLUMBING: 15B1 GENERAL INSTRUCTIONS 156 1 -1 PREBID SITE VISIT PRIOR TO SUBMITTING BID, VISIT THE SITE AND BECOME FULLY INFORMED AS TO THE CONDITIONS UNDER WHICH THE WORK IS TO BE DONE. 15B 1 -2 COORDINATION COORDINATE WORK WITH THAT OF OTHER TRADES SO THAT THE VARIOUS COMPONENTS OF THE SYSTEMS WILL BE INSTALLED AT THE PROPER TIME, WILL FIT THE AVAILABLE SPACE, AND WILL ALLOW PROPER SERVICE ACCESS TO THOSE ITEMS REQUIRING MAINTENANCE. 15B 1 -3 ORDINANCES AND CODES WORK PERFORMED UNDER THIS CONTRACT SHALL, AT A MINIMUM, BE IN CONFORMANCE WITH APPLICABLE NATIONAL, STATE AND LOCAL CODES HAVING JURISDICTION. PROCURE AND PAY FOR PERMITS AND LICENSES REQUIRED FOR THE ACCOMPLISHMENT OF THE WORK HEREIN DESCRIBED. WHERE REQUIRED, OBTAIN, PAY FOR AND FURNISH CERTIFICATES OF INSPECTION TO OWNER. 15B 1 -4 SLEEVES PROVIDE SLEEVES FOR VERTICAL PIPE PASSING THROUGH SLAB ON GRADE. SLEEVES SHALL BE SCHEDULE 40 STEEL PIPE, TWO NOMINAL PIPE SIZES LARGER THAN THE PIPE SERVED. SEAL WATER -TIGHT WITH SILICONE CAULK. 15B2 PLUMBING PIPING 15B 2--1 PIPING MATERIALS DOMESTIC WATER (COLD AND HOT WATER): DOMESTIC WATER PIPING INSTALLED ABOVE THE FLOOR SLAB INSIDE THE BUILDING SHALL BE TYPE "L" HARD TEMPER COPPER TUBE WITH WROUGHT COPPER FITTINGS AND SOLDERED CONNECTIONS. INTERIOR WASTE AND VENT BELOW SLAB: WASTE AND VENT PIPE BELOW SLAB INSIDE BUILDING SHALL BE SERVICE WEIGHT CAST IRON SOIL PIPE WITH HUB AND SPIGOT FITTINGS. PVC SCHEDULE 40 DWV ASTM D2665 PIPE WITH PVC MEETING AST M 01784, CELL CLASS 12454 -B WITH ASTM 2665 SOCKET FITTINGS WITH SOLVENT WELD JOINTS IS ALSO PERMITTED WHERE APPROVED BY CODE. INTERIOR WASTE AND VENT ABOVE SLAB: WASTE AND VENT PIPE ABOVE SLAB INSIDE BUILDING SHALL BE HUBLESS CAST IRON SOIL PIPE AND FITTINGS WITH HUBLESS COUPLINGS. PVC SCHEDULE 40 DWV ASTM D2665 PIPE WITH PVC MEETING ASTM B1784, CELL CLASS 12454 -B WITH ASTM 2665 SOCKET FITTINGS WITH SOLVENT WELD JOINTS IS ALSO PERMITTED WHERE APPROVED BY CODE, (NOTE: PVC PIPING IS NOT ALLOWED IN CEILING RETURN AIR PLENUMS) INDIRECT AND CONDENSATE DRAIN: INDIRECT AND CONDENSATE DRAIN PIPE SHALL BE TYPE "M" HARD COPPER WITH WROUGHT COPPER FITTINGS FOR 1" AND SMALLER AND "DWV" COPPER WITH WROUGHT COPPER DRAINAGE PATTERN FITTINGS FOR 1 -1/4" AND LARGER HARD TEMPER COPPER TUBE OR SCHEDULE 40 PVC PIPE AND FITTINGS WITH SOLVENT WELD JOINTS WHERE ALLOWED BY CODE. (NOTE: PVC PIPING IS NOT ALLOWED IN CEILING RETURN AIR PLENUMS). 15B 2 -2 PIPING INSULATION DOMESTIC COLD WATER AND HOT WATER, INDIRECT AND CONDENSATE DRAIN PIPE: 1" ONE -PIECE FIBERGLASS COVERING WITH FIRE - RESISTANT JACKET WITH SELF - SEALING LAP. FOR PIPING AT HANGERS PROVIDE 8" LONG SECTIONS OF HIGH DENSITY, HIGH TEMPERATURE CALCIUM SILICATE, FIBERGLASS, OR 8" LONG STYROFOAM BILLETS. INSULATION SHALL BE CONTINUOUS ALONG THE PIPE SURFACE, EXCEPT AT VALVES, UNIONS, AND WHERE PIPING IS EXPOSED AT FIXTURES. PROVIDE 1" FIBERGLASS INSULATION ON VENT PIPING WITHIN SIX FEET OF VENT THROUGH THE OF ROOF. PROVIDE INSULATION PROTECTION SHIELD AT EACH HANGER FOR INSULATED PIPING. COVER FITTINGS WITH ONE -PIECE PVC PREMOLDED INSULATING COVERS. FITTING COVERS, JACKETS AND ADHESIVES SHALL NOT EXCEED FLAME SPREAD RATING OF 25 AND SMOKE DEVELOPMENT RATING OF 50 PER ASTM E84. AT ALL ELBOWS AND TEES, FILL VOIDS BETWEEN COVERS AND PIPING WITH FIBERGLASS INSULATION AND TAPE JOINTS. INSTALL PIPE INSULATION IN COMPLIANCE WITH MANUFACTURER'S RECOMMENDATIONS. WHERE PREMOLDED INSULATING FITTINGS ARE NOT APPROVED BY LOCAL AUTHORITIES, MITER INSULATION AT FITTINGS. 15B 2 -3 PIPING JOINTS COPPER TUBING: JOINTS IN HARD TEMPER TUBING SHALL BE SOLDERED JOINTS USING LEAD -FREE 95/5 SOLDER EXCEPT WHERE TUBING IS INSTALLED BELOW GRADE OR BELOW THE BASE SLAB, IN WHICH CASE JOINTS SHALL BE SOLDERED WITH SILVER SOLDER (SILFOS). JOINTS IN SOFT TEMPER COPPER TUBING SHALL BE OF THE FLARED TYPE INSTALLED IN COMPLIANCE WITH THE FITTING MANUFACTURER'S RECOMMENDATIONS. CAST IRON PIPE BELOW GRADE: JOINTS IN BELL AND SPIGOT CAST IRON WASTE AND VENT PIPE SHALL BE NEOPRENE COMPRESSION GASKETS, TYSEAL OR EQUAL. CAST IRON PIPE ABOVE GRADE: JOINTS IN HUBLESS PIPE SHALL BE STANDARD CISPI 310 -85 COUPLING. PVC PIPE: CLEAN JOINTS FREE FROM DEBRIS AND MOISTURE. APPLY PVC PRIMER MEETING ASTM F656 TO EACH JOINT. APPLY SOLVENT CEMENT MEETING ASTM D2564 AND MAKE JOINT WHILE WET AND IN ACCORDANCE WITH ASTM D2855. 15B 2 -4 PIPING INSTALLATION GENERAL: CLEAN PIPE THOROUGHLY PRIOR TO INSTALLATION. REAM ENDS OF PIPE TO REMOVE BURRS. INSTALL WITH ADEQUATE CLEARANCE FOR INSTALLATION OF COVERINGS WHERE REQUIRED. NEATLY ALIGN PIPE, CONNECT IT SECURELY, AND SUPPORT IT FROM THE BUILDING STRUCTURE WITH HANGERS AS SPECIFIED BELOW. PROVIDE CHROME-PLATED ESCUTCHEONS ON PIPES PASSING THROUGH CEILINGS, FLOORS OR WALLS OF FINISHED SPACES. RUN PIPES FREELY THROUGH FLOOR AND WALL PENETRATIONS USING PIPE SLEEVES. DO NOT GROUT IN PLACE UNLESS REQUIRED FOR STRUCTURAL FIRE INTEGRITY. INSTALL PIPE CONCEALED IN FINISHED SPACES WHEREVER POSSIBLE. USE A DIELECTRIC UNION WHERE FERROUS AND COPPER PIPE CONNECT. HANGER & SUPPORTS: CONNECT HANGERS TO THE STRUCTURE WITH SIDE BEAM CONNECTORS AND ALL THREAD HANGER RODS. PROVIDE ENGINEERED SUPPORT STRUTS BETWEEN JOISTS AND OTHER STRUCTURAL MEMBERS AS REQUIRED TO PROVIDE A RIGID HANGING INSTALLATION. DO NOT HANG PIPES FROM OTHER PIPES, CONDUIT OR DUCTWORK. PROVIDE HANGER RODS AND SPACE HANGERS AT INTERVALS AS SPECIFIED. PROVIDE SUPPORT WITHIN 1' OF EACH ELBOW AND TEE. PROVIDE SUPPORTS WITHIN 1' OF EACH EQUIPMENT CONNECTION. INSTALL HANGER TYPES OR SUPPORTS FOR VARIOUS PIPING AS FOLLOWS: COPPER TUBE: 1 -1/2" AND SMALLER - EVERY 6' WITH 3/8 "HANGER RODS; 2" - EVERY 10' WITH 1/2"HANGER RODS; SUPPORT VERTICAL COPPER TUBE EVERY 10'. CAST IRON PIPE: EVERY 10' AND WITHIN 1' OF EACH JOINT. 2" AND SMALLER WITH 3/8" HANGER RODS; 3" WITH 1/2" HANGER RODS; 4" WITH 5/8" HANGER RODS; SUPPORT VERTICAL CAST IRON PIPE EVERY 15' PVC PIPE: SUPPORT ALL PIPES SIZES EVERY 4'. 1 -1/2" AND SMALLER WITH 3/8" HANGER RODS; 2" WITH 1/2 "HANGER RODS; 2 -1/2" AND 3" WITH 1/2" HANGER RODS, 4" AND LARGER WITH 5/8" HANGER RODS. SUPPORT VERTICAL PVC PIPE EVERY 4'. SUPPORTS ON FLOOR: SUPPORT PIPING FROM THE FLOOR WHERE REQUIRED FOR FERROUS PIPE OR INSULATED COPPER TUBE, SHALL BE GALVANIZED STEEL WITH PIPE SADDLE, THREADED SHANK FOR HEIGHT ADJUSTMENT AND FLOOR STAND SECURED TO THE FLOOR. BELOW GROUND INSTALLATION FOR SOIL AND WASTE: INSTALL SOIL AND WASTE PIPING TO A UNIFORM SLOPE OF NOT LESS THAN 1/8" PER FOOT FOR PIPING 4" OR LARGER, AND NOT LESS THAN 1/4" PER FOOT FOR PIPING 3" OR SMALLER. LAY PIPE WITH HUB END UPSTREAM. MAKE CHANGES IN DIRECTION IN AS REQUIRED BY THE INSTALLATION PRACTICES ADOPTED AND ENFORCED BY LOCAL CODES. ABOVE GROUND INSTALLATION FOR SOIL AND WASTE: INSTALL SOIL AND WASTE PIPING TO A UNIFORM SLOPE OF NOT LESS THAN 1/8" PER FOOT FOR PIPING 4" OR LARGER, AND NOT LESS THAN 1/4" PER FOOT FOR PIPING 3" OR SMALLER. SUPPORT PIPE WITHIN 12" OF EACH JOINT. MAKE CHANGES IN DIRECTION FROM HORIZONTAL TO VERTICAL, AT FIXTURE BRANCHES AND OTHER BRANCH CONNECTIONS WITH SANITARY "TEES" OR SHORT SWEEP "ELLS ". MAKE CHANGES IN DIRECTION AS REQUIRED BY THE INSTALLATION PRACTICES ADOPTED AND ENFORCED BY LOCAL CODES. PLUMBING VENT: CONNECT PLUMBING VENT PIPES AS REQUIRED BY THE INSTALLATION PRACTICES ADOPTED AND ENFORCED BY LOCAL CODES OFFICIAL, AND EXTEND VENT PIPES FULL SIZE THROUGH THE ROOF LINE. GRADE PIPE TO A UNIFORM SLOPE SO AS TO DRAIN BACK BY GRAVITY TO THE DRAINAGE PIPING SYSTEM. VENTS PASSING THROUGH THE ROOF SHALL BE MINIMUM 3" SIZE EXCEPT IN TROPICAL CLIMATES, PER LOCAL CODES. TURN FLASHING DOWN INTO STACKS AT LEAST 2 ", AND EXTEND FLASHING 24" IN ALL DIRECTIONS FROM THE PIPE AT THE ROOF LINE. APPLY WHITE LEAD PIPE DOPE ON MALE STEEL PIPE THREADS. V ENT LINES SHALL BE AIR AND WATER TIGHT. DOMESTIC WATER: ARRANGE COLD AND HOT, WATER PIPING TO DRAIN AT THE LOWEST POINT IN EACH SYSTEM. INSTALL AT LEAST ONE PIPE UNION ADJACENT TO ALL SHUTOFF VALVES, AT CONNECTION POINTS OF EACH PIECE OF EQUIPMENT, AND ELSEWHERE IN THE SYSTEM WHERE REQUIRED TO ALLOW PROPER MAINTENANCE. 15B 2 -5 PIPING SANITIZATION SANITIZE THE ENTIRE DOMESTIC WATER PIPING SYSTEM (COLD AND HOT WATER) WITH A SOLUTION CONTAINING NOT LESS THAN 50 PPM AVAILABLE CHLORINE. KEEP SOLUTION IN THE SYSTEM FOR A MINIMUM OF 24 HOURS, WITH EACH VALVE BEING OPERATED SEVERAL TIMES DURING THE PERIOD. AFTER COMPLETION, FLUSH SYSTEM WITH CITY WATER UNTIL CHLORINE RESIDUAL IS LOWERED TO INCOMING CITY WATER LEVEL. 15B3 PLUMBING SPECIALTIES 15B 3 -1 WATER HAMMER ARRESTORS PROVIDE WATER HAMMER ARRESTORS AT VALVES OR BATTERIES OF FIXTURES AS INDICATED ON THE DRAWINGS TO PREVENT WATER HAMMER. INSTALL WATER HAMMER ARRESTORS PER THE PLUMBING AND DRAINAGE INSTITUTE PDI WH -201 INSTALLATION INSTRUCTIONS. 15B 3 -2 CLEANOUTS AND FLOOR DRAINS CLEANOUTS AND FLOOR DRAINS SHALL BE BY ONE MANUFACTURER IF POSSIBLE. PROVIDE LONG SWEEP FITTINGS FOR CLEANOUT EXTENSIONS; SHORT SWEEPS AT START OF RUNS OR CHANGE IN DIRECTION AND COMBINATION WYE AND EIGHT BEND FITTINGS IN HORIZONTAL RUNS. INSTALL CLEANOUTS WITH A MINIMUM OF 18" CLEAR ALL AROUND, CONSULT LOCAL CODES FOR OTHER REQUIREMENTS, FOR EASY SYSTEM MAINTENANCE. INSTALL PLUG WITH TEFLON JOINT COMPOUND. FLOOR DRAINS: SHALL BE AS SCHEDULED ON THE DRAWINGS. FLOOR CLEANOUTS: SHALL BE AS SCHEDULED ON THE DRAWINGS. INSTALL CLEANOUTS AT POINTS AS NOTED ON THE DRAWINGS, AT THE BUILDING EXIT; AT A MINIMUM OF EVERY 50 FEET IN HORIZONTAL SOIL AND WASTE LINES; AND AT TURNS OF PIPE GREATER THAN 45 DEGREES I CLEANOUTS SHALL BE FULL SIZE OF THE PIPE UP TO 4 ", AND 4" SIZE FOR PIPES LARGER THAN 4 ". DETERMINE THE TYPE OF FLOOR COVERING TO BE USED AT EACH FLOOR CLEANOUT LOCATION AND PROVIDE TOP WITH VARIATIONS SUITABLE FOR FLOOR COVERING (CARPET MARKERS, RECESSED FOR TILE AND SCORIATED FOR UNFINISHED FLOOR). ROUGH -IN AND INSTALL EACH FLOOR CLEANOUT FLUSH WITH THE FINISHED FLOOR CONSTRUCTION. WALL CLEANOUTS: SHALL BE AS SCHEDULED ON THE DRAWINGS. INSTALL WALL CLEANOUTS AT POINTS AS NOTED ON THE DRAWINGS; AT THE FOOT OF EACH SOIL OR WASTE STACK; AT HORIZONTAL SOIL AND WASTE BRANCHES LONGER THAN FIVE FEET NOT SERVED BY A FLOOR CLEANOUT; CONSULT LOCAL CODES FOR INSTALLATION AT SPECIFIC FIXTURE TYPES. INSTALL WALL CLEANOUTS ABOVE THE FLOOD RIM OF THE FIXTURE SERVED WITHIN FOUR FEET OF THE FLOOR AND INSTALL EXTENSIONS FROM THE CLEANOUT TEE TO THE WALL TO LOCATE THE PLUG WITHIN 2" OF THE WALL WHERE REQUIRED. INSTALL CLEANOUTS ON URINALS AND SINKS WHERE REQUIRED BY CODE. 15B 3 -3 VALVES BALL VALVES: 2" AND SMALLER, TWO PIECE BRONZE BODY, WITH SCREWED ENDS, CHROME PLATED BRONZE BALL WITH CONVENTIONAL PORT, 400 PSI, BLOW -OUT PROOF STEM. CHECK VALVES: CHECK VALVES SHALL BE CLASS 125. CHECK VALVES FOR INSTALLATION IN HORIZONTAL PIPE RUNS SHALL BE OF THE "SWING DISC" DESIGN. HORIZONTAL CHECK VALVES 2 -1/2" AND SMALLER SHALL BE SCREWED BRONZE BODY AND BRONZE DISC. CHECK VALVES FOR INSTALLATION IN VERTICAL PIPE RUNS SHALL BE OF THE "VERTICAL LIFT" DESIGN. VERTICAL CHECK VALVES 2 -1/2" AND SMALLER SHALL BE SCREWED BRONZE BODY AND BRONZE DISC. UNIONS: FERROUS UNIONS SHALL BE COMBINATION IRON AND BRASS, GROUND JOINT WITH SCREWED ENDS. COPPER UNIONS SHALL BE CAST BRONZE SWEAT TYPE WITH GROUND JOINT. FERROUS TO COPPER UNIONS SHALL BE DIELECTRIC TYPE WITH THREADED NYLON INSERT. 15B 3 -4 SYSTEM ACCESSORIES ICE MAKER CONNECTION BOXES SHALL BE AS SPECIFIED ON THE DRAWINGS WITH WALL FLANGE AND WATER CONNECTION. 1584 PLUMBING FIXTURES AND EQUIPMENT 15B 4 -1 PLUMBING FIXTURES FURNISH AND INSTALL PLUMBING FIXTURES, SEE THE DRAWINGS FOR QUANTITIES AND DESCRIPTIONS. FIXTURES SHOWN ON THE DRAWINGS OR SPECIFIED HEREIN SHALL BE FURNISHED AND INSTALLED, SET FIRM AND TRUE, CONNECTED TO REQUIRED PIPING SERVICES, THOROUGHLY CLEANED, LEFT CLEAN AND READY FOR USE. EXPOSED FITTINGS AND PIPING AT THE FIXTURES SHALL BE CHROME- PLATED, AND WATER SUPPLY PIPING SHALL BE VALVED AT EACH FIXTURE. 15B 4 -2 PLUMBING FIXTURE TRIM FAUCETS AND TRIM IN CONTACT WITH DRINKING WATER SHALL MEET OR EXCEED THE SAFE WATER DRINKING ACT (SWDA) LEAD -FREE STANDARDS OF ANSI /NSF STANDARD 61, SECTION 9. PROVIDE FAUCETS AS SCHEDULED ON DRAWINGS. FIXTURE P -TRAPS SHALL BE 17 GAUGE BRASS BODY WITH CLEANOUT, 17 GAUGE SEAMLESS TUBULAR WALL BEND WITH CAST BRASS SLIP NUT, SHALLOW STEEL FLANGE, ALL CHROME PLATED. PROVIDE HANDICAP INSULATION KITS FOR LAVATORIES AND SINKS ON EXPOSED WATER AND WASTE PIPES AND FITTINGS, INCLUDING OFFSET DRAIN AND CONTINUOUS WASTE COVERS WHERE REQUIRED. SECTION 15C AUTOMATIC SPRINKLER SYSTEM: 15C1 GENERAL 15C 1 -1 GENERAL REQUIREMENTS ALL REQUIREMENTS UNDER THE GENERAL AND SUPPLEMENTARY CONDITIONS OF THESE SPECIFICATIONS SHALL BE A PART OF THIS SECTION. EACH CONTRACTOR SHALL BE RESPONSIBLE TO THOROUGHLY BECOME FAMILIAR WITH ALL ITS CONTENTS AS TO CODES AND REQUIREMENTS THAT AFFECT THIS DIVISION OR SECTION. THE WORK REQUIRED UNDER THIS SECTION INCLUDES ALL MATERIAL, EQUIPMENT, APPLIANCES, TRANSPORTATION, SERVICES, AND LABOR REQUIRED TO COMPLETE THE ENTIRE SYSTEM AS REQUIRED BY THE DRAWINGS AND SPECIFICATIONS. THE SPECIFICATIONS WRITTEN HEREIN AND THE ASSOCIATED DRAWINGS ARE COMPLEMENTARY, AND ANY PORTION OF THE WORK DESCRIBED IN ONE, SHALL BE PROVIDED AS IF DESCRIBED IN BOTH. IN THE EVENT OF DISCREPANCIES ON THE DRAWINGS AND SPECIFICATIONS, THE CONTRACTOR SHALL ADVISE THE ENGINEER OF SAME PRIOR TO PROCEEDING WITH THE WORK INVOLVED, IN ORDER THAT CORRECT PROGRESS OF THE WORK MAY BE ENSURED. REFER TO SECTION 158 PLUMBING FOR ADDITIONAL REQUIREMENTS THAT APPLY TO THIS INSTALLATION THAT ARE NOT WRITTEN HEREIN. 15C 1 -2 DEFINITIONS FURNISH: THE TERM "FURNISH" IS USED TO MEAN "SUPPLY AND DELIVER TO THE PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION AND SIMILAR OPERATIONS." INSTALL: THE TERM "INSTALL" IS USED TO DESCRIBE OPERATIONS AT THE PROJECT SITE INCLUDING THE ACTUAL "UNLOADING, UNPACKING, ASSEMBLY, ERECTION, PLACING, ANCHORING, APPLYING, WORKING TO DIMENSION, FINISHING, CURING, PROTECTING, CLEANING, AND SIMILAR OPERATIONS." PROVIDE: THE TERM "PROVIDE" MEANS "TO FURNISH AND INSTALL, COMPLETE AND READY FOR THE INTENDED USE." FURNISHED BY OWNER OR FURNISHED BY OTHERS: THE ITEM WILL BE FURNISHED BY THE OWNER OR OTHERS. IT IS TO BE INSTALLED AND CONNECTED UNDER THE REQUIREMENTS OF THIS DIVISION, COMPLETE AND READY FOR OPERATION, INCLUDING ITEMS INCIDENTAL TO THE WORK, INCLUDING SERVICES NECESSARY FOR PROPER INSTALLATION AND OPERATION. THE INSTALLATION SHALL BE INCLUDED UNDER THE GUARANTEE REQUIRED BY THIS DIVISION. ENGINEER: WHERE REFERENCED IN THIS DIVISION, "ENGINEER" IS THE ENGINEER OF RECORD AND THE DESIGN PROFESSIONAL FOR THE WORK UNDER THIS DIVISION, AND IS A CONSULTANT TO, AND AN AUTHORIZED REPRESENTATIVE OF, THE ARCHITECT, AS DEFINED IN THE GENERAL AND /OR SUPPLEMENTARY CONDITIONS. WHEN USED IN THIS DIVISION, IT MEANS INCREASED INVOLVEMENT BY, AND OBLIGATIONS TO, THE ENGINEER, IN ADDITION TO INVOLVEMENT BY, AND OBLIGATIONS TO, THE "ARCHITECT ". AHJ: THE LOCAL CODE AND /OR INSPECTION AGENCY (AUTHORITY) HAVING JURISDICTION OVER THE WORK. THE TERMS "APPROVED EQUAL ", "EQUIVALENT ", OR "EQUAL" ARE USED SYNONYMOUSLY AND SHALL MEAN "ACCEPTED BY OR ACCEPTABLE TO THE ENGINEER AS EQUIVALENT TO THE ITEM OR MANUFACTURER SPECIFIED ". THE TERM "APPROVED" SHALL MEAN LABELED, LISTED, OR BOTH, BY A NATIONALLY RECOGNIZED TESTING LABORATORY (E.G. UL, ETL, CSA), AND ACCEPTABLE TO THE AHJ OVER THIS PROJECT. 15C 1 -3 INSPECTION OF SITE THE CONTRACTOR SHALL PERSONALLY INSPECT THE SITE OF THE PROPOSED WORK AND BECOME FULLY INFORMED AS TO THE CONDITIONS UNDER WHICH THE WORK IS TO BE DONE. FAILURE TO DO SO WILL NOT BE CONSIDERED SUFFICIENT JUSTIFICATION TO REQUEST OR OBTAIN EXTRA COMPENSATION OVER AND ABOVE THE CONTRACT PRICE. 15C 1 -4 SCOPE MODIFY EXISTING WET -PIPE, FIRE PROTECTION AUTOMATIC SPRINKLER SYSTEM FOR THE AREA OF WORK SHOWN ON THE DRAWINGS. CONTRACTOR SHALL BE APPROVED AND STATE LICENSED FOR DESIGN AND INSTALLATION OF FIRE PROTECTION SYSTEMS. THE WORK DONE UNDER THIS SECTION SHALL BE PERFORMED ONLY BY A CONTRACTOR WHOSE WORKMEN ARE EXPERIENCED AND REGULARLY ENGAGED IN THE INSTALLATION OF FIRE PROTECTION SYSTEMS. CONTRACTOR SHALL BE CAPABLE OF PREPARING HYDRAULIC CALCULATIONS AND SYSTEM LAYOUTS. PROVIDE ALL FIRE SPRINKLER ALARM DEVICES INCLUDING WATERFLOW ALARM AND VALVE TAMPER SWITCHES FOR ALL SYSTEM CONTROL VALVES. COORDINATE ALL WIRING AND CONDUIT FOR A COMPLETE AND FUNCTIONAL INSTALLATION. SYSTEM SHALL, AT A MINIMUM, BE IN ACCORDANCE WITH THE LATEST EDITION OF NFPA 13, 24, UNDERWRITERS LABORATORIES (UL), AND MUST BE ACCEPTABLE TO THE OWNER'S INSURER, THE AUTHORITY HAVING JURISDICTION AND ALL APPLICABLE LOCAL, STATE AND NATIONAL CODES AND STANDARDS. WHERE THE CONTRACT DOCUMENTS EXCEED THE REQUIREMENTS OF THE REFERENCED CODES, STANDARDS, ETC., THE CONTRACT DOCUMENTS SHALL TAKE PRECEDENCE. WORK SHALL INCLUDE, BUT SHALL NOT NECESSARILY BE LIMITED TO THE FOLLOWING: 1) DESIGN AND INSTALLATION OF A COMPLETE WET-PIPE FIRE PROTECTION SPRINKLER SYSTEM FOR THE ENTIRE BUILDING OR AREA OF WORK SHOWN ON THE DRAWINGS. 15C 1 -5 SYSTEM DESIGN THIS CONTRACTOR SHALL VERIFY DESIGN CRITERIA AND RATING HAZARDS WITH THE OWNER'S INSURER PRIOR TO DESIGNING THE SYSTEM. WATERFLOW AND PRESSURE TEST DATA SHALL BE ACQUIRED BEFORE SYSTEM IS CALCULATED AND BE DATED NOT MORE THAN 12 MONTHS PRIOR TO THE SUBMITTAL OF SPRINKLER DRAWINGS. ARRANGEMENTS FOR AND COST OF FLOW TESTS SHALL BE THE CONTRACTOR'S RESPONSIBILITY. HYDRAULIC CALCULATIONS SHALL BE SUBMITTED INCLUDING SUPPLY AND DEMAND GRAPH AS REQUIRED; ALL HYDRAULIC REFERENCE POINTS AND AREA OF APPLICATION SHALL APPEAR ON THE PLAN. CONTRACTOR SHALL VERIFY WITH AUTHORITY HAVING JURISDICTION ANY MINIMUM SAFETY FACTOR REQUIREMENTS. DEMAND SHALL NOT BE LESS THAN 10% BELOW THE SUPPLY AT THE DEMAND POINT. PROTECT AREA OF WORK WITH A WET TYPE SPRINKLER SYSTEM DESIGNED IN ACCORDANCE WITH NFPA 13. DESIGN SYSTEM FOR ORDINARY HAZARD GROUP 2, 0.20 GPM /SF OVER THE HYDRAULICALLY REMOTE 1500 SF AREA. INCLUDE MINIMUM 250 GPM HOSE ALLOWANCE ADDED AT THE BASE OF RISER. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE HYDRAULIC CALCULATIONS AS REQUIRED, THE FINAL SYSTEM DESIGN, AND THE LAYOUT OF ALL COMPONENTS OF THE SYSTEM AS REQUIRED FOR THE APPROVAL BY THE OWNER'S INSURER, THE AUTHORITY HAVING JURISDICTION AND ALL APPLICABLE LOCAL, STATE AND NATIONAL CODES AND STANDARDS. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR COORDINATING SYSTEM LAYOUT WITH OTHER CONTRACTORS. CHANGES TO SYSTEM DESIGN DUE TO LACK OF COORDINATION SHALL BE PAID FOR BY THIS CONTRACTOR. DESIGNS REQUIRING CUTTING OF STRUCTURAL MEMBERS FOR PASSAGE OF SPRINKLER PIPES OR HANGERS SHALL NOT BE ACCEPTED. WHEN DESIGN APPEARANCE OR SIMILAR ASPECTS REQUIRES CUTTING, DUE TO ECONOMY, IT SHALL BE HELD TO AN ABSOLUTE MINIMUM AND DONE ONLY WITH THE ARCHITECT AND STRUCTURAL ENGINEER'S WRITTEN APPROVAL. ANY EXCESSIVE REQUIREMENTS OF THIS TYPE SHALL BE IDENTIFIED DURING THE BID PERIOD. SPRINKLER SPACING SHALL CONFORM TO NFPA 13. EXTENDED COVERAGE SPRINKLERS SHALL NOT BE USED IN UNFINISHED (SHELL) SPACES. THE HYDRAULIC AREA OF OPERATION SHALL NOT BE REDUCED AS ALLOWED BY NFPA 13 FOR AREAS UTILIZING QUICK RESPONSE SPRINKLERS. 15C 1 -7 ELECTRONIC DRAWINGS IN PREPARATION OF SHOP DRAWINGS, CONTRACTOR MAY, AT HIS OPTION, OBTAIN ELECTRONIC DRAWING FILES IN AUTOCAD VERSION 14, 2002 OR DXF FORMAT ON 3.5 INCH FLOPPY DISK, 100 MB ZIP DISK OR CD -ROM DISK, AS DESIRED, FROM THE ENGINEER FOR A FEE OF $200 FOR A DRAWING SET UP TO 12 SHEETS AND $15 PER SHEET FOR EACH ADDITIONAL SHEET. CONTRACTOR SHALL CONTACT THE ENGINEER TO OBTAIN THE NECESSARY RELEASE AGREEMENT FORM AND TO SPECIFY SHIPPING METHOD AND DRAWING FORMAT. PAYMENT MUST BE RECEIVED BEFORE ELECTRONIC DRAWING FILES WILL BE SENT. 15C 1 -8 RECORD DRAWINGS DURING PROGRESS OF THE WORK OF THIS SECTION, THIS CONTRACTOR SHALL MAINTAIN AN ACCURATE RECORD OF ALL CHANGES MADE IN THE INSTALLATION OF THE SYSTEM. UPON COMPLETION OF THE WORK, ACCURATELY TRANSFER ALL RECORD INFORMATION TO THREE IDENTICAL BLUELINE PRINT SETS OF THE APPROVED SHOP DRAWINGS. INSERT ONE SET INTO EACH COPY OF THE MANUAL DESCRIBED BELOW. 15C 1 -9 TESTING AND ACCEPTANCE UPON COMPLETION OF EACH PHASE OF THE INSTALLATION, EACH SYSTEM SHALL BE TESTED IN CONFORMANCE WITH LOCAL CODE REQUIREMENTS AND AS NOTED BELOW. THE CONTRACTOR SHALL FURNISH ALL LABOR AND EQUIPMENT REQUIRED TO PROPERLY TEST ALL SPRINKLER EQUIPMENT INSTALLED UNDER THIS CONTRACT, AND HE SHALL ASSUME ALL COSTS INVOLVED IN MAKING THE TESTS, AND REPAIRING AND /OR REPLACING ALL DAMAGE RESULTING THEREFROM. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND THE AUTHORITY HAVING JURISDICTION, THREE (3) WORKING DAYS PRIOR TO MAKING SPRINKLER SYSTEM TESTS. CONCEALED WORK SHALL REMAIN UNCOVERED UNTIL THE REQUIRED TESTS HAVE BEEN COMPLETED, BUT IF NECESSARY DUE TO CONSTRUCTION PROCEDURE, TESTS ON PORTIONS OF THE WORK MAY BE MADE, AND IF SATISFACTORY, THE WORK MAY BE CONCEALED. ALL PIPING SHALL BE SUBJECT TO THE SPECIFIED PRESSURE FOR THE UNINTERRUPTED SPECIFIED PERIOD. ALL LINES, JOINTS, FLANGES, VALVE STEMS, ETC., SHALL BE LEAK TIGHT. ALL SYSTEM DEFECTS SHALL BE REPAIRED OR REPLACED WITH NEW MATERIALS. CAULKING OF DEFECTIVE JOINTS, CRACKS OR HOLES WILL NOT BE PERMITTED. TESTS SHALL BE REPEATED AFTER DEFECTS HAVE BEEN ELIMINATED. ALL TESTS SHALL BE MADE IN THE PRESENCE OF THE ADMINISTRATIVE AUTHORITY AND /OR THE OWNER'S AUTHORIZED REPRESENTATIVE. UPON COMPLETION OF THE SYSTEMS INSTALLATION, AND PRIOR TO ACCEPTANCE BY THE ENGINEER AND OWNER, THIS CONTRACTOR SHALL MAKE GENERAL OPERATING TESTS TO DEMONSTRATE THAT ALL EQUIPMENT AND SYSTEMS ARE IN PROPER WORKING ORDER, AND ARE FUNCTIONING IN CONFORMANCE WITH THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. ABOVE GROUND PIPING SHALL BE TESTED IN ACCORDANCE WITH NFPA 13. ALL SPRINKLER PIPING SHALL BE HYDROSTATICALLY TESTED AT A MINIMUM PRESSURE OF 200-PSI FOR A MINIMUM 2 -HOUR PERIOD OF TIME. CORRECT ANY FAULTY OR LEAKING JOINTS AND PIPE. THE USE OF ANY SUBSTANCE OR MATERIAL ADDED TO THE WATER TO CORRECT LEAKS SHALL NOT BE PERMITTED. AFTER COMPLETION OF THE INSTALLATION, TEST, RETEST, AND MAKE ALL CORRECTIONS NECESSARY TO SECURE ACCEPTANCE BY THE FIRE MARSHAL AND /OR ANY OTHER AUTHORITY HAVING JURISDICTION. FURNISH ALL TEST EQUIPMENT AND PERSONNEL REQUIRED. o& O11 15C 1 -10 SYSTEM MANUAL UPON COMPLETION OF THE INSTALLATION, AND AS A CONDITION OF ITS ACCEPTANCE, CONTRACTOR SHALL COMPILE THREE 8 -1/2" BY 11" MANUALS, FIRMLY BOUND IN HEAVYWEIGHT PLASTIC OR PAPER COVER TO WITHSTAND HARD USE. LOOSE -LEAF BINDING IS NOT ACCEPTABLE. MANUALS SHALL BE DELIVERED TO THE ARCHITECT, AND SHALL CONTAIN THE FOLLOWING ITEMS: 1) IDENTIFICATION CLEARLY VISIBLE ON OR THROUGH THE COVER, THE NAME OF THE PROJECT AND "FIRE SPRINKLER SYSTEM MANUAL ". 2) NEATLY TYPED INDEX AT FRONT WITH ALL EMERGENCY INFORMATION CLEARLY IDENTIFIED. 3) COMPLETE UST OF ALL SYSTEM COMPONENTS WITH MANUFACTURER'S NAMES, CATALOG NUMBERS, AND ALL DATA FOR ORDERING PARTS. 4) ONE COPY OF THE RECORD DRAWINGS, AS DESCRIBED ABOVE. 5) ALL INFORMATION REQUIRED TO SECURE EMERGENCY REPAIRS OR SERVICE. 6) CONTRACTOR'S "MATERIAL AND TEST CERTIFICATE(S) FOR SPRINKLER SYSTEM ", AS DESCRIBED IN NFPA 13. 15C 1 -11 GUARANTEE THE ENTIRE INSTALLATION SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE DATE OF SUBSTANTIAL COMPLETION. IF DEFECTS OCCUR DURING THE ONE -YEAR GUARANTEE PERIOD, THIS CONTRACTOR SHALL REPAIR OR REPLACE SUCH DEFECTS AT NO EXPENSE TO THE OWNER AND TO THE SATISFACTION OF THE ENGINEER. 15C 1 -12 INSTRUCTIONS AFTER COMPLETION OF ALL INSTALLATION, TESTS, ETC., AND PRIOR TO THE FINAL ACCEPTANCE DATE, THE CONTRACTOR SHALL INSTRUCT THE BUILDING OWNER AND HIS SELECTED PERSONNEL IN THE OPERATION OF THE SPRINKLER SYSTEM AND THE PROCEDURE TO CONDUCT QUARTERLY MAIN DRAIN TESTS AS REQUIRED BY NFPA 25. SPECIAL CARE SHALL BE TAKEN TO MAKE SURE THE BUILDING PERSONNEL WILL IMMEDIATELY RECOGNIZE WHETHER THE MAIN VALVE IS IN AN OPEN POSITION, WILL KNOW HOW TO DRAIN THE SYSTEM, AND WILL KNOW HOW TO TEST THE ALARM VALVE IF APPLICABLE. THE BUILDING PERSONNEL SHALL ALSO BE MADE FAMILIAR WITH THE EXISTENCE AND CONTENTS OF THE SYSTEM MANUAL DESCRIBED IN THIS SPECIFICATION. 15C2 MATERIALS AND INSTALLATION 15C 2 -1 PRODUCTS ALL FIRE PROTECTION SYSTEM COMPONENTS SHALL BE UNDERWRITER'S LABORATORIES LISTED FOR THEIR INTENDED USE. 15C 2 -2 PIPING AND COMPONENTS SPRINKLER PIPING 2" AND SMALLER SHALL BE SCHEDULE 40. PIPES SHALL HAVE WELDED, THREADED, OR MECHANICALLY JOINED FITTINGS, BASED ON THE PIPE MATERIAL AND SIZE PER NFPA 13 REQUIREMENTS. ACCEPTABLE ALTERNATIVES TO SCHEDULE 10 AND SCHEDULE 40 PIPE SHALL BE MANUFACTURED TO STANDARDS RECOGNIZED BY NFPA 13. THREADED PIPE SHALL HAVE A CORROSION RESISTANCE RATING OF 1.0 OR GREATER. CRIMP -TYPE COUPLINGS SHALL NOT BE USED. THREADABLE THINWALL PIPE WITH CORROSION RESISTANCE RATING LESS THAN 1.0 NOT PERMITTED. 15C 2 -3 SPRINKLERS SPRINKLERS IN AREAS WITH GYPSUM BOARD CEILINGS SHALL BE FULLY CONCEALED TYPE WITH WHITE DROP -AWAY COVERPLATES. SPRINKLERS IN AREAS WITH SUSPENDED ACOUSTICAL CEILINGS SHALL BE FULLY CONCEALED TYPE WITH WHITE DROP -AWAY COVERPLATES. 15C 2 -4 INSTALLATION COORDINATE ALL SCHEDULING AND WORK WITH OTHER TRADES SO AS TO PREVENT CONFLICTS, AND TO ENSURE ORDERLY PROGRESS OF THE WORK, WITH A MINIMUM OF DELAYS. WHEN SPRINKLER PIPING IS INSTALLED WITHOUT COORDINATING WITH OTHER TRADES AND CONFLICTS OCCUR, SPRINKLER PIPING SHALL BE RELOCATED AS REQUIRED AT NO ADDITIONAL COST TO THE OWNER TO RESOLVE THE CONFLICTS. PIPING IN AREAS HAVING CEIUNGS, OTHER THAN THE UNDERSIDE OF THE ROOF DECK, SHALL BE CONCEALED. ALL PIPING SHALL BE CLEAN AND FREE OF RUST. INSTALL SYSTEM SUCH THAT ALL PIPING IS RIGIDLY SECURED AND SUPPORTED. ALL DUCTWORK, LIGHTS, STRUCTURAL MEMBERS AND MAIN RUNS OF PIPING SHALL TAKE PRECEDENCE OVER SPRINKLER PIPING. CUTTING OF STRUCTURAL MEMBERS FOR PASSAGE OF SPRINKLER PIPES OR HANGERS WILL NOT BE PERMITTED. ALL HORIZONTAL PIPING IN CEILING SPACE SHALL BE AT AN ELEVATION ABOVE THE TOP OF LIGHT FIXTURES AND AIR OUTLETS TO ALLOW FOR ACCESS TO LIGHT FIXTURES AND AIR OUTLETS WITHOUT REMOVING HORIZONTAL PIPING. ROUTE ALL SPRINKLER PIPING AND PROVIDE ALL OFFSETS, BENDS, AND ELBOWS AROUND ALL MECHANICAL, ELECTRICAL, AND STRUCTURAL MEMBERS AS REQUIRED. CONTRACTOR SHALL COORDINATE WITH THE FIRE ALARM CONTRACTOR AND /OR ELECTRICAL CONTRACTOR THE CONNECTION OF THE FIRE SPRINKLER ALARM DEVICES TO THE FIRE ALARM SYSTEM OR FIRE SPRINKLER MONITORING PANEL AS REQUIRED. WHERE EXPOSED PIPING PASSES THROUGH FINISH WORK, CHROME PLATED (OR OTHER FINISH ACCEPTABLE TO THE ARCHITECT) SPLIT WALL PLATES OR ESCUTCHEONS SHALL BE INSTALLED TO FIT SNUGLY AROUND THE PIPING. WHERE PIPING IS CONCEALED OR INSTALLED IN UNFINISHED AREAS, SUITABLE PLATES SHALL BE PROVIDED AT EACH PENETRATION TO ASSURE EFFECTIVENESS OF CONSTRUCTION AS A FIRE STOP. ALL OPENINGS FOR PIPING SHALL BE ANTICIPATED AND INDICATED ON THE APPROVED SHOP DRAWINGS. ANY ADDITIONAL CUTTING OF OPENINGS MUST HAVE THE WRITTEN APPROVAL OF THE ARCHITECT. CONTRACTOR SHALL COMPLETE THE AUTOMATIC FIRE SPRINKLER SYSTEM, AS SOON AS POSSIBLE, WHEN BUILDING CONSTRUCTION ALLOWS. THEN THE CONTRACTOR SHALL ACTIVATE THE SYSTEM FOR ITS INTENDED USE. AFTER THE SYSTEM HAS BEEN ACTIVATED FOR CONTINUOUS USE, WATER CHARGES IF ANY WILL BE PAID BY OWNER. PIPING SHALL BE ROUTED PARALLEL TO BUILDING LINES. 15C 2-5 PENETRATIONS SEAL ALL FIRE PROTECTION FLOOR, WALL AND ROOF PENETRATIONS WATERTIGHT AND WEATHERTIGHT. CAULK AROUND FIRE PROTECTION PENETRATIONS WITH 3M CP -25, OR APPROVED EQUAL FIRE BARRIER CAULK (THICKNESS AS REQUIRED AND RECOMMENDED BY MANUFACTURER) TO MAINTAIN FIRE RESISTANCE RATING OF FIRE - RATED ASSEMBLIES. END OF SECTION 15C 10370 RICHMOND AVENUE, SUITE 370 HOUSTON, TX 77042 TEL 713 783 7707 FAX 713 783 7797 www.hei.eeg.com 0750001294 RJS JMH SIM FEB —8 2008 PERMIT CENTEJ-, HENDERSON ENGINEERS: EXP. 11/ Q7/ 0 v 4+Z CZ 0 V ISSUED 7 REVISED DATE HEALTH DEPT SUBMITTAL 98% OWNER REVIEW HEALTH DEPT RVSNS ISSUED FOR PERMIT PLUMBING SPECS P -3.0 12.17.07 01.03.08 01.11.08 01.25.08 1 2 3 4 5 6 7 8 9 10 SECTION 15C: AUTOMATIC SPRINKLER SYSTEM: 15C1 GENERAL 15C 1 -1 GENERAL REQUIREMENTS ALL REQUIREMENTS UNDER THE GENERAL AND SUPPLEMENTARY CONDITIONS OF THESE SPECIFICATIONS SHALL BE A PART OF THIS SECTION. EACH CONTRACTOR SHALL BE RESPONSIBLE TO THOROUGHLY BECOME FAMILIAR WITH ALL ITS CONTENTS AS TO CODES AND REQUIREMENTS THAT AFFECT THIS DIVISION OR SECTION. THE WORK REQUIRED UNDER THIS SECTION INCLUDES ALL MATERIAL, EQUIPMENT, APPLIANCES, TRANSPORTATION, SERVICES, AND LABOR REQUIRED TO COMPLETE THE ENTIRE SYSTEM AS REQUIRED BY THE DRAWINGS AND SPECIFICATIONS. THE SPECIFICATIONS WRITTEN HEREIN AND THE ASSOCIATED DRAWINGS ARE COMPLEMENTARY, AND ANY PORTION OF THE WORK DESCRIBED IN ONE, SHALL BE PROVIDED AS IF DESCRIBED IN BOTH. IN THE EVENT OF DISCREPANCIES ON THE DRAWINGS AND SPECIFICATIONS, THE CONTRACTOR SHALL ADVISE THE ENGINEER OF SAME PRIOR TO PROCEEDING WITH THE WORK INVOLVED, IN ORDER THAT CORRECT PROGRESS OF THE WORK MAY BE ENSURED. REFER TO SECTION 15B PLUMBING FOR ADDITIONAL REQUIREMENTS THAT APPLY TO THIS INSTALLATION THAT ARE NOT WRITTEN HEREIN. 15C 1 -2 DEFINITIONS FURNISH: THE TERM "FURNISH" IS USED TO MEAN "SUPPLY AND DELIVER TO THE PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION AND SIMILAR OPERATIONS." INSTALL: THE TERM "INSTALL" IS USED TO DESCRIBE OPERATIONS AT THE PROJECT SITE INCLUDING THE ACTUAL "UNLOADING, UNPACKING, ASSEMBLY, ERECTION, PLACING, ANCHORING, APPLYING, WORKING TO DIMENSION, FINISHING, CURING, PROTECTING, CLEANING, AND SIMILAR OPERATIONS." PROVIDE: THE TERM "PROVIDE" MEANS "TO FURNISH AND INSTALL, COMPLETE AND READY FOR THE INTENDED USE." FURNISHED BY OWNER OR FURNISHED BY OTHERS: THE ITEM WILL BE FURNISHED BY THE OWNER OR OTHERS. IT IS TO BE INSTALLED AND CONNECTED UNDER THE REQUIREMENTS OF THIS DIVISION, COMPLETE AND READY FOR OPERATION, INCLUDING ITEMS INCIDENTAL TO THE WORK, INCLUDING SERVICES NECESSARY FOR PROPER INSTALLATION AND OPERATION. THE INSTALLATION SHALL BE INCLUDED UNDER THE GUARANTEE REQUIRED BY THIS DIVISION. ENGINEER: WHERE REFERENCED IN THIS DIVISION, "ENGINEER" IS THE ENGINEER OF RECORD AND THE DESIGN PROFESSIONAL FOR THE WORK UNDER THIS DIVISION, AND IS A CONSULTANT TO, AND AN AUTHORIZED REPRESENTATIVE OF, THE ARCHITECT, AS DEFINED IN THE GENERAL AND /OR SUPPLEMENTARY CONDITIONS. WHEN USED IN THIS DIVISION, IT MEANS INCREASED INVOLVEMENT BY,' AND OBLIGATIONS TO, THE ENGINEER, IN ADDITION TO INVOLVEMENT BY, AND OBLIGATIONS TO, THE "ARCHITECT ". AHJ: THE CODE AND /OR INSPECTION AGENCY (AUTHORITY) HAVING JURISDICTION OVER THE WORK. THE TERMS "APPROVED EQUAL ", "EQUIVALENT ", OR "EQUAL" ARE USED SYNONYMOUSLY AND SHALL MEAN "ACCEPTED BY OR ACCEPTABLE TO THE ENGINEER AS EQUIVALENT TO THE ITEM OR MANUFACTURER SPECIFIED ". THE TERM "APPROVED" SHALL MEAN LABELED, LISTED, OR BOTH, BY A NATIONALLY RECOGNIZED TESTING LABORATORY (E.G. UL, ETL, CSA), AND ACCEPTABLE TO THE AHJ OVER THIS PROJECT. 15C 1 -3 INSPECTION OF SITE THE CONTRACTOR SHALL PERSONALLY INSPECT THE SITE OF THE PROPOSED WORK AND BECOME FULLY INFORMED AS TO THE CONDITIONS UNDER WHICH THE WORK IS TO BE DONE. FAILURE TO DO SO WILL NOT BE CONSIDERED SUFFICIENT JUSTIFICATION TO REQUEST OR OBTAIN EXTRA COMPENSATION OVER AND ABOVE THE CONTRACT PRICE. 15C 1 -4 SCOPE PROVIDE COMPLETE WITH ALL RELATED ITEMS, A WET —PIPE, AUTOMATIC FIRE SPRINKLER SYSTEM FOR THE AREA OF WORK SHOWN ON THE DRAWINGS. CONTRACTOR SHALL BE APPROVED AND STATE LICENSED FOR DESIGN AND INSTALLATION OF FIRE PROTECTION SYSTEMS. THE WORK DONE UNDER THIS SECTION SHALL BE PERFORMED ONLY BY A CONTRACTOR WHOSE WORKMEN ARE EXPERIENCED AND REGULARLY ENGAGED IN THE INSTALLATION OF FIRE PROTECTION SYSTEMS. CONTRACTOR SHALL BE CAPABLE OF PREPARING HYDRAULIC CALCULATIONS AND SYSTEM LAYOUTS. PROVIDE ALL FIRE SPRINKLER ALARM DEVICES INCLUDING WATERFLOW ALARM AND VALVE TAMPER SWITCHES FOR ALL SYSTEM CONTROL VALVES. COORDINATE ALL WIRING AND CONDUIT FOR A COMPLETE AND FUNCTIONAL INSTALLATION. SYSTEM SHALL, AT A MINIMUM, BE IN ACCORDANCE WITH THE LATEST EDITION OF NFPA 13, UNDERWRITERS LABORATORIES (UL), AND MUST BE ACCEPTABLE TO THE OWNER'S INSURER, THE AHJ AND ALL APPLICABLE LOCAL, STATE AND NATIONAL CODES AND STANDARDS. WHERE THE CONTRACT DOCUMENTS EXCEED THE REQUIREMENTS OF THE REFERENCED CODES, STANDARDS, ETC., THE CONTRACT DOCUMENTS SHALL TAKE PRECEDENCE. WORK SHALL INCLUDE, BUT SHALL NOT NECESSARILY BE LIMITED TO THE FOLLOWING: 1) DESIGN AND INSTALLATION OF A COMPLETE WET —PIPE, AUTOMATIC FIRE SPRINKLER SYSTEM FOR THE AREA OF WORK SHOWN ON THE DRAWINGS OR SPECIFIED HEREIN. 2) PORTIONS OF SYSTEMS SUBJECT TO FREEZING OR TEMPERATURES BELOW 40' F SHALL BE PROTECTED AGAINST FREEZING AS REQUIRED BY NFPA 13. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRS AND FOR ALL COSTS INCURRED FROM DAMAGE CAUSED BY FREEZING OF THE FIRE PROTECTION SYSTEM. 15C 1 -5 SYSTEM DESIGN CONTRACTOR SHALL VERIFY DESIGN CRITERIA AND RATING HAZARDS WITH THE OWNER'S INSURER PRIOR TO DESIGNING THE SYSTEM. WATERFLOW AND PRESSURE TEST DATA SHALL BE ACQUIRED BEFORE SYSTEM IS CALCULATED AND BE DATED NOT MORE THAN 12 MONTHS PRIOR TO THE SUBMITTAL OF SPRINKLER SHOP DRAWINGS. ARRANGEMENTS FOR AND COST OF FLOW TESTS SHALL BE THE CONTRACTOR'S RESPONSIBILITY. HYDRAULIC CALCULATIONS SHALL BE SUBMITTED, AS REQUIRED, INCLUDING SUPPLY AND DEMAND GRAPH; ALL HYDRAULIC REFERENCE POINTS AND AREA OF APPLICATION SHALL APPEAR ON THE PLAN. CONTRACTOR SHALL VERIFY WITH AHJ ANY MINIMUM SAFETY FACTOR REQUIREMENTS. DEMAND SHALL NOT BE LESS THAN 10% BELOW THE SUPPLY AT THE DEMAND POINT. PROTECT OFFICE AND RESTROOM AREAS, UNLESS NOTED OTHERWISE WITH A WET TYPE SPRINKLER SYSTEM DESIGNED IN ACCORDANCE WITH NFPA 13. DESIGN SYSTEM FOR LIGHT HAZARD, 0.10 GPM /SF OVER THE HYDRAULICALLY REMOTE 1500 SF AREA. INCLUDE MINIMUM 100 GPM HOSE ALLOWANCE ADDED AT THE BASE OF RISER. PROTECT THE AREA OF WORK, UNLESS NOTED OTHERWISE WITH A WET TYPE SPRINKLER SYSTEM DESIGNED IN ACCORDANCE WITH NFPA 13. DESIGN SYSTEM FOR ORDINARY HAZARD GROUP 2, 0.20 GPM /SF OVER THE HYDRAULICALLY REMOTE 1500 SF AREA. INCLUDE MINIMUM 250 GPM HOSE ALLOWANCE ADDED AT THE BASE OF RISER. RISER.THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE HYDRAULIC CALCULATIONS IF REQUIRED, THE FINAL SYSTEM DESIGN, AND THE LAYOUT OF ALL COMPONENTS OF THE SYSTEM AS REQUIRED FOR APPROVAL BY THE OWNER'S INSURER AND THE AHJ. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR COORDINATING SYSTEM LAYOUT WITH OTHER CONTRACTORS. CHANGES TO SYSTEM DESIGN DUE TO LACK OF COORDINATION SHALL BE PAID FOR BY THIS CONTRACTOR. DESIGNS REQUIRING CUTTING OF STRUCTURAL MEMBERS FOR PASSAGE OF SPRINKLER PIPES OR HANGERS SHALL NOT BE ACCEPTED. WHEN DESIGN APPEARANCE OR SIMILAR ASPECTS REQUIRE CUTTING, DUE TO ECONOMY, IT SHALL BE HELD TO AN ABSOLUTE MINIMUM AND DONE ONLY WITH THE ARCHITECT AND STRUCTURAL ENGINEER'S WRITTEN APPROVAL. ANY EXCESSIVE REQUIREMENTS OF THIS TYPE SHALL BE IDENTIFIED DURING THE BID PERIOD. SPRINKLER SPACING SHALL CONFORM TO NFPA 13. EXTENDED COVERAGE SPRINKLERS SHALL NOT BE USED IN UNFINISHED (SHELL) SPACES. THE HYDRAULIC AREA OF OPERATION SHALL NOT BE REDUCED AS ALLOWED BY NFPA 13 FOR AREAS UTILIZING QUICK RESPONSE SPRINKLERS. 15C 1 -6 SHOP DRAWINGS SIX (6) COPIES OF SHOP DRAWINGS AND HYDRAULIC CALCULATIONS SHALL BE FURNISHED TO THE ARCHITECT AND /OR ENGINEER, FOR HIS APPROVAL. SHOP DRAWINGS SHALL MEET THE REQUIREMENTS OF NFPA 13 FOR WORKING LEVEL DRAWINGS AND SHALL INCLUDE THE FOLLOWING: 1) SUBMIT WORKING PLANS PER NFPA 13 INCLUDING LAYOUT DRAWINGS OF THE COMPLETE OVERHEAD SPRINKLER SYSTEM INDICATING RELATIONSHIP OF SPRINKLER PIPING AND SPRINKLERS TO ALL OTHER OVERHEAD ITEMS INCLUDING CEILING GRID AND TILES, LIGHT FIXTURES, DIFFUSERS, REGISTERS, GRILLES, DUCTWORK, STRUCTURE, SOFFITS, OBSTRUCTIONS, ETC. LOCATION OF RISERS, PIPING, ETC., SHALL BE AS INCONSPICUOUS AS POSSIBLE AND SHALL FULFILL ALL FUNCTIONAL REQUIREMENTS. SYSTEM DESIGN CAPABILITIES AND DEMAND SHALL ALSO BE NOTED ON THE DRAWINGS. 2) SUBMIT COMPLETE DETAILS AND SECTIONS AS REQUIRED TO CLEARLY DEFINE AND CLARIFY THE DESIGN, INCLUDING A MATERIALS LIST DESCRIBING ALL PROPOSED MATERIALS BY MANUFACTURER'S NAME AND CATALOG NUMBER. 3) HYDRAULIC CALCULATIONS (AS REQUIRED). 4) PRODUCT DATA FOR ALL FIRE SPRINKLER SYSTEM COMPONENTS. CLEARLY INDICATE COMPONENTS TO BE USED WHERE MULTIPLE COMPONENTS APPEAR ON THE SAME CUT SHEET. 15C 1 -7 ELECTRONIC DRAWINGS IN PREPARATION OF SHOP DRAWINGS, CONTRACTOR MAY, AT HIS OPTION, OBTAIN ELECTRONIC DRAWING FILES IN AUTOCAD VERSION 14, 2006 OR DXF FORMAT, AS DESIRED, FROM THE ENGINEER FOR A FEE OF $200 FOR A DRAWING SET UP TO 12 SHEETS AND $15 PER SHEET FOR A SET OF MORE THAN 12 SHEETS. CONTRACTOR SHALL CONTACT THE ENGINEER TO OBTAIN THE NECESSARY RELEASE AGREEMENT FORM AND TO SPECIFY SHIPPING METHOD AND DRAWING FORMAT. PAYMENT MUST BE RECEIVED BEFORE ELECTRONIC DRAWING FILES WILL BE SENT. 15C 1 -8 RECORD DRAWINGS DURING PROGRESS OF THE WORK OF THIS SECTION, THIS CONTRACTOR SHALL MAINTAIN AN ACCURATE RECORD OF ALL CHANGES MADE IN THE INSTALLATION OF THE SYSTEM. UPON COMPLETION OF THE WORK, ACCURATELY TRANSFER ALL RECORD INFORMATION TO ONE SET OF THE APPROVED SHOP DRAWINGS. PROVIDE FINAL RECORD SET TO OWNER OR LEAVE ON SITE UPON COMPLETION. 15C 1 -9 GUARANTEE THE ENTIRE INSTALLATION FOR THE SCOPE OF WORK SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE DATE OF SUBSTANTIAL COMPLETION. LABOR (INCLUDING TRAVEL EXPENSES) TO TROUBLE — SHOOT, REPAIR, REPROGRAM, OR REPLACE COMPONENTS SHALL BE FURNISHED BY THIS CONTRACTOR AT NO CHARGE DURING THE WARRANTY PERIOD. 15C2 MATERIALS AND INSTALLATION 15C 2 -1 PRODUCTS ALL FIRE PROTECTION SYSTEM COMPONENTS SHALL BE UNDERWRITER'S LABORATORIES LISTED FOR THEIR INTENDED USE. 15C 2 -2 PIPING AND COMPONENTS SPRINKLER PIPING 2 -1/2" AND LARGER SHALL BE SCHEDULE 10 OR SCHEDULE 40 BLACK STEEL. SPRINKLER PIPING 2" AND SMALLER SHALL BE SCHEDULE 40. PIPES SHALL HAVE WELDED, THREADED, OR MECHANICALLY JOINED FITTINGS, BASED ON THE PIPE MATERIAL AND SIZE PER NFPA 13 REQUIREMENTS. ACCEPTABLE ALTERNATIVES TO SCHEDULE 10 AND SCHEDULE 40 PIPE SHALL BE MANUFACTURED TO STANDARDS RECOGNIZED BY NFPA 13. PIPE SHALL HAVE A CORROSION RESISTANCE RATING OF 1.0 OR GREATER. CRIMP —TYPE COUPLINGS SHALL NOT BE USED. THREADABLE THINWALL PIPE WITH CORROSION RESISTANCE RATING LESS THAN 1.0 NOT PERMITTED. ALL PIPING ON THE EXTERIOR OF THE BUILDING AND /OR EXPOSED TO THE ELEMENTS SHALL BE EXTERNALLY GALVANIZED. 15C 2 -3 SPRINKLERS SPRINKLERS IN AREAS WITH GYPSUM BOARD CEILINGS SHALL BE FULLY CONCEALED TYPE WITH WHITE COVERPLATES. SPRINKLERS IN AREAS WITH SUSPENDED ACOUSTICAL CEILINGS SHALL BE FULLY CONCEALED TYPE WITH WHITE COVERPLATES. SPRINKLERS IN AREAS WITH EXPOSED PIPING MAY BE PENDENT OR UPRIGHT TYPES WITH ROUGH BRASS FINISH. PROVIDE QUICK RESPONSE SPRINKLERS IN ALL LIGHT HAZARD AREAS. 15C 2 -4 SERVICE ENTRANCE FIRE PROTECTION SERVICE ENTRANCE IS EXISTING TO REMAIN IN LANDLORD SPACE. PROVIDE NEXT TO THE SPRINKLER RISER, A PRINTED SHEET, PROTECTED BY GLASS OR A TRANSPARENT PLASTIC COVER, GIVING BRIEF INSTRUCTIONS REGARDING CONTROL, EMERGENCY PROCEDURE AND OTHER DATA AS REQUIRED BY NFPA 13. FOR HYDRAULICALLY DESIGNED SYSTEMS, A PLACARD MUST BE PERMANENTLY ATTACHED TO THE RISER INDICATING THE LOCATION, AND THE BASIS OF DESIGN (DISCHARGE DENSITY AND SYSTEM DEMAND). ALL CONTROL VALVE SUPERVISORY SWITCHES AND WATERFLOW ALARM SWITCHES SHALL BE PROVIDED BY THIS CONTRACTOR.FIRE DEPARTMENT CONNECTION IS EXISTING TO REMAIN. PROVIDE A CABINET CONTAINING SPARE SPRINKLERS AND APPROPRIATE WRENCH(ES) PER NFPA 13, AT THE FIRE SPRINKLER SYSTEM SERVICE ENTRANCE AREA. 15C3 EXECUTION 15C 3 -1 PIPING AND FINISHES PIPING IN AREAS HAVING CEILINGS, OTHER THAN THE UNDERSIDE OF THE ROOF DECK, SHALL BE CONCEALED. PIPING IN AREAS WITHOUT CEILINGS MAY BE EXPOSED BUT KEPT AT A MINIMUM DISTANCE FROM THE DECK. ALL PIPING SHALL BE CLEAN AND FREE OF RUST. INSTALL SYSTEM SUCH THAT ALL PIPING IS RIGIDLY SECURED AND SUPPORTED. ALL DUCTWORK, LIGHTS, STRUCTURAL MEMBERS AND MAIN RUNS OF PIPING SHALL TAKE PRECEDENCE OVER SPRINKLER PIPING. CUTTING OF STRUCTURAL MEMBERS FOR PASSAGE OF SPRINKLER PIPES OR HANGERS WILL NOT BE PERMITTED. ALL HORIZONTAL PIPING IN CEILING SPACE SHALL BE AT AN ELEVATION ABOVE THE TOP OF LIGHT FIXTURES AND AIR OUTLETS TO ALLOW FOR ACCESS TO LIGHT FIXTURES AND AIR OUTLETS WITHOUT REMOVING HORIZONTAL PIPING. ROUTE ALL SPRINKLER PIPING AND PROVIDE ALL OFFSETS, BENDS, AND ELBOWS AROUND ALL MECHANICAL, ELECTRICAL, AND STRUCTURAL MEMBERS AS REQUIRED. WHERE EXPOSED PIPING PASSES THROUGH FINISH WORK, CHROME PLATED (OR OTHER FINISH ACCEPTABLE TO THE ARCHITECT) SPLIT WALL PLATES OR ESCUTCHEONS SHALL BE INSTALLED TO FIT SNUGLY AROUND THE PIPING. WHERE PIPING IS CONCEALED OR INSTALLED IN UNFINISHED AREAS, SUITABLE PLATES SHALL BE PROVIDED AT EACH PENETRATION TO ASSURE EFFECTIVENESS OF CONSTRUCTION AS A FIRE STOP. ALL OPENINGS FOR PIPING SHALL BE ANTICIPATED AND INDICATED ON THE APPROVED SHOP DRAWINGS. ANY ADDITIONAL CUTTING OF OPENINGS MUST HAVE THE WRITTEN APPROVAL OF THE ARCHITECT. PIPING SHALL BE ROUTED PARALLEL TO MAJOR BUILDING LINES. DESIGN SHALL ALLOW FOR SUITABLE DRAINAGE OF SYSTEM, ALL TO MEET WITH THE APPROVAL OF THE AFOREMENTIONED AUTHORITIES. PROVIDE ACCESS PANELS AS REQUIRED. ALL DRAIN LOCATIONS REQUIRING ACCESS PANELS SHALL BE APPROVED BY THE ARCHITECT PRIOR TO INSTALLATION. SPRINKLERS IN SUSPENDED CEILINGS SHALL BE NOT LESS THAN 6— INCHES FROM THE GRID IN ALL DIRECTIONS. 1 5C 3 -2 COORDINATION CONTRACTOR SHALL COORDINATE THE CONNECTION OF ANY NEW FIRE SPRINKLER ALARM DEVICES TO THE FIRE ALARM SYSTEM AS REQUIRED. COORDINATE ALL SCHEDULING AND WORK WITH OTHER TRADES SO AS TO PREVENT CONFLICTS, AND TO ENSURE ORDERLY PROGRESS OF THE WORK, WITH A MINIMUM OF DELAYS. WHEN SPRINKLER PIPING IS INSTALLED WITHOUT COORDINATING WITH OTHER TRADES AND CONFLICTS OCCUR, SPRINKLER PIPING SHALL BE RELOCATED AS REQUIRED AT NO ADDITIONAL COST TO THE OWNER TO RESOLVE THE CONFLICTS. 15C 3 -3 PENETRATIONS SEAL ALL FIRE PROTECTION FLOOR, WALL AND ROOF PENETRATIONS WATERTIGHT AND WEATHERTIGHT. CAULK AROUND FIRE PROTECTION PENETRATIONS WITH 3M CP -25, OR APPROVED EQUAL FIRE BARRIER CAULK (THICKNESS AS REQUIRED AND RECOMMENDED BY MANUFACTURER) TO MAINTAIN FIRE RESISTANCE RATING OF FIRE — RATED ASSEMBLIES. 15C 3 -4 TESTING AND ACCEPTANCE CONTRACTOR SHALL COMPLETE THE AUTOMATIC FIRE SPRINKLER SYSTEM, AS SOON AS POSSIBLE, WHEN BUILDING CONSTRUCTION ALLOWS. FOLLOWING SYSTEM INSTALLATION, THE CONTRACTOR SHALL PLACE THE SYSTEM IN SERVICE. AFTER THE SYSTEM HAS BEEN PLACED IN SERVICE FOR CONTINUOUS USE, WATER CHARGES, IF ANY WILL BE PAID BY OWNER. UPON COMPLETION OF THE SYSTEMS INSTALLATION, AND PRIOR TO ACCEPTANCE BY THE ENGINEER AND OWNER, THIS CONTRACTOR SHALL MAKE GENERAL OPERATING TESTS TO DEMONSTRATE THAT ALL EQUIPMENT AND SYSTEMS ARE IN PROPER WORKING ORDER, AND ARE FUNCTIONING IN CONFORMANCE WITH THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. ABOVE GROUND PIPING SHALL BE TESTED IN ACCORDANCE WITH NFPA 13. ALL SPRINKLER PIPING SHALL BE HYDROSTATICALLY TESTED AT A MINIMUM PRESSURE OF 200—PSI FOR A MINIMUM 2 —HOUR PERIOD OF TIME. CORRECT ANY FAULTY OR LEAKING JOINTS AND PIPE. THE USE OF ANY SUBSTANCE OR MATERIAL ADDED TO THE WATER TO CORRECT LEAKS SHALL NOT BE PERMITTED. CAULKING OF DEFECTIVE JOINTS, CRACKS OR HOLES WILL NOT BE PERMITTED. TESTS SHALL BE REPEATED AFTER DEFECTS HAVE BEEN ELIMINATED. ALL TESTS SHALL BE MADE IN THE PRESENCE OF THE AHJ AND /OR THE OWNER'S AUTHORIZED REPRESENTATIVE. UPON COMPLETION OF EACH PHASE OF THE INSTALLATION, EACH SYSTEM SHALL BE TESTED IN CONFORMANCE WITH LOCAL CODE REQUIREMENTS. THE CONTRACTOR SHALL FURNISH ALL LABOR AND EQUIPMENT REQUIRED TO PROPERLY TEST ALL SPRINKLER EQUIPMENT INSTALLED UNDER THIS CONTRACT, AND HE SHALL ASSUME ALL COSTS INVOLVED IN MAKING THE TESTS, AND REPAIRING AND /OR REPLACING ALL DAMAGE RESULTING THEREFROM. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND THE AUTHORITY HAVING JURISDICTION, THREE (3) WORKING DAYS PRIOR TO MAKING SPRINKLER SYSTEM TESTS. CONCEALED WORK SHALL REMAIN UNCOVERED UNTIL THE REQUIRED TESTS HAVE BEEN COMPLETED, BUT IF NECESSARY DUE TO CONSTRUCTION PROCEDURE, TESTS ON PORTIONS OF THE WORK MAY BE MADE, AND IF SATISFACTORY, THE WORK MAY BE CONCEALED. 15C 3 -5 INSTRUCTIONS AFTER COMPLETION OF ALL INSTALLATION, TESTS, ETC., AND PRIOR TO THE FINAL ACCEPTANCE DATE, THE CONTRACTOR SHALL INSTRUCT THE BUILDING OWNER AND HIS SELECTED PERSONNEL IN THE OPERATION OF THE SPRINKLER SYSTEM AND THE PROCEDURE TO CONDUCT QUARTERLY MAIN DRAIN TESTS AS REQUIRED BY NFPA 25. SPECIAL CARE SHALL BE TAKEN TO MAKE SURE THE BUILDING PERSONNEL WILL IMMEDIATELY RECOGNIZE WHETHER THE MAIN VALVE IS IN AN OPEN POSITION, WILL KNOW HOW TO DRAIN THE SYSTEM, AND WILL KNOW HOW TO TEST THE SYSTEM. THE BUILDING PERSONNEL SHALL ALSO BE MADE FAMILIAR WITH THE EXISTENCE AND CONTENTS OF THE SYSTEM MANUAL DESCRIBED IN THIS SPECIFICATION. END OF SECTION 15C w 011 r � �?F• fir ;': `9 FEB-82006 PERMIT CENTER HENDERSON ENGINEERS 10370 RICHMOND AVENUE, SUITE 370 HOUSTON, TX 77042 TEL 713 783 7707 FAX 713 783 7797 www.hei- eng.com 0750001294 R15 JMH SLM ISSUED / REVISED DATE HEALTH DEPT SUBMITTAL 12.17.07 98% OWNER REVIEW 01.03.08 HEALTH DEPT RVSNS 01.11.08 ISSUED FOR PERMIT 01.25.08 Q co w N a CD � z o w z W ' - < Q Z Lo I— I 0 Cn FIRE PROTECTION SPECIFICATIONS P -3.1 EXP. 11/07/08 "V 0 i*6 1 2 4 6 7 8 9 10 MECHANICAL SYMBOLS I NG I E. THIS IS A MASTER LEGEND AND NOT ALL SYMBOLS, ETC. ARE NECESSARILY USED ON THE DRAWINGS. HVAC EQUIPMENT & DUCTWORK NOTE ALL DUCT DIMENSIONS SHOWN ON DRAWINGS ARE INSIDE DIMENSIONS. SEE SECTION 15250 OF THE SPECIFICATION FOR DUCTWORK TO RECEIVE INSULATION OR LINER. Jr L J r RD ® THERMOSTAT EXISTING DUCTWORK OR EQUIPMENT TO REMAIN BRANCH DUCT WITH 45' RECTANGLE —ROUND BRANCH FITTING ELBOW WITH TURNING VANES RETURN, EXHAUST, OR OUTSIDE AIR DUCT UP RETURN, EXHAUST, OR OUTSIDE AIR DUCT DOWN SUPPLY AIR DUCT UP SUPPLY AIR DUCT DOWN EQUIPMENT WITH FLEXIBLE DUCT CONNECTION 10" CSD -1 300 CFM NECK SIZE, TYPE, CFM OF SUPPLY DIFFUSER OR REGISTER MANUAL VOLUME DAMPER SQUARE TO ROUND TRANSITION DUCT MOUNTED SMOKE DETECTOR (SD= SUPPLY /RD= RETURN) ABBREVIATIONS AFF BPS BD CFM DDC DX EA FFA FFB GPM IN WC MAX MBH ABOVE FINISHED FLOOR BUILDING AUTOMATION SYSTEM BACKDRAFT DAMPER CUBIC FEET PER MINUTE DIRECT DIGITAL CONTROL DIRECT EXPANSION EXHAUST AIR FROM FLOOR ABOVE FROM FLOOR BELOW GALLONS PER MINUTE INCHES OF WATER COLUMN MAXIMUM 1000 BTU PER HOUR MC MIN NC OA RA SA SD TFA TFB TYP UNO W/ W/O MECHANICAL CONTRACTOR MINIMUM NOISE CRITERIA OUTSIDE AIR RETURN AIR SUPPLY AIR SMOKE DUCT DETECTOR TO FLOOR ABOVE TO FLOOR BELOW TYPICAL UNLESS NOTED OTHERWISE WITH WITHOUT STANDARD MOUNTING HEIGHTS MECHANICAL THERMOSTATS (USER ADJUSTABLE) CONTROLS (CENTERLINE) (AFF, AFG, UNLESS NOTED OTHERWISE) 48" 48" ANNOTATION MECHANICAL PLAN CALLOUT MECHANICAL EQUIPMENT DESIGNATION (OWNER FURNISHED AND INSTALLED UNLESS NOTED OTHERWISE, RE: M -3.0) CONNECTION POINT OF NEW WORK TO EXISTING DETAIL REFERENCE UPPER NUMBER INDICATES DETAIL NUMBER LOWER NUMBER INDICATES SHEET NUMBER I • i I I I i I I • I REMOTE STOCKROOM MECHANICAL PLAN SCALE: 1 /4" =1' -0" IMAM w I I I ""11. o III I 111 e 0 C MECHANICAL FLOOR PLAN SCALE: 1 /4 " =1' -0" MECHANICAL PLAN NOTES: 1® EXISTING "VENTROL" REFRIGERATION UNIT TO REMAIN. REPAIR /REFURBISH SYSTEM TO "LIKE —NEW" CONDITION. REPLACE EQUIPMENT IF NECESSARY. REPLACE EXISTING "VENTROL" ROOF MOUNTED CONDENSING UNIT WITH NEW AS PROVIDED BY OWNER. ® CONNECT NEW SUPPLY AIR DUCT TO EXISTING 12x12 SUPPLY AIR DUCT FROM SHELL BUILDING SYSTEM. CONNECT NEW EXHAUST AIR DUCT TO EXISTING 8"95 EXHAUST AIR DUCT FROM SHELL BUILDING SYSTEM. ® LOCATE NEW FAN —COIL UNIT AS INDICATED. UNIT, INCLUDING FILTER SECTION, SHALL BE ACCESSIBLE FOR SERVICE FROM A CEILING ACCESS PANEL. SUSPEND UNIT FROM STRUCTURE PER MANUFACTURER'S RECOMMENDATIONS. MOUNT UNIT BETWEEN STRUCTURAL JOISTS AS HIGH AS POSSIBLE WHILE COORDINATING WITH OTHER BUILDING SYSTEMS TO ALLOW WORKING CLEARANCES AS REQUIRED BY CODE AND UNIT MANUFACTURER. RE: 2,3/M -2.0. COORDINATE INSTALLATION OF UNIT SUPPORTS AND PIPING TO MAINTAIN ACCESS AND CLEARANCE FOR FILTER REPLACEMENT. O5 REFER TO PLUMBING DRAWINGS FOR CONDENSATE DRAIN LINES. ® ELECTRICAL CONTRACTOR SHALL PROVIDE A SMOKE DETECTOR IN THE SUPPLY DUCTWORK OF THE FAN —COIL UNIT. SMOKE DETECTOR SHALL BE ACCESSIBLE THRU THE LAY—IN CEILING. RE: 3/M -2.0. ® NEW "VENTROL" REFRIGERATION UNIT WITH REMOTE CONDENSING UNIT PROVIDED BY GODIVA AND INSTALLED BY THE MECHANICAL CONTRACTOR. RE: 1/M -2.0. SUSPEND UNIT FROM STRUCTURE WITH THREADED RODS AND VIBRATION ISOLATORS. ® CONNECT NEW 6 "0 EXHAUST DUCT TO FAN /LIGHT COMBINATION. PROVIDE TRANSITION AS REQUIRED. ® SUPPLY AIR OF VAV BOX INCREASED FROM THAT SHOWN ON SHEEL BUILDING DOCUMENTS TO PROVIDE MINIMUM OUTDOOR AIR REQUIRED BY LOCAL CODES. ROOF TOP UNIT PROVIDING SUPPLY AIR ONLY HAS 18.34% OUTDOOR AIR CAPACITY. GENERAL NEW NOTES: 1. PRIOR TO SUBMITTING BID, VISIT THE JOB SITE AND BECOME FULLY ACQUAINTED WITH THE EXISTING CONDITIONS OF THE PROJECT. REVIEW THE GENERAL NOTES, SPECIFICATIONS AND OTHER DRAWINGS FOR ADDITIONAL REQUIREMENTS WHICH MAY NOT BE SPECIFICALLY CALLED OUT IN THIS PORTION OF THE CONSTRUCTION DOCUMENTS. NOTIFY ARCHITECT AND /OR ENGINEER VIA OWNER OF CONFLICTS OR DISCREPANCIES PRIOR TO SUBMISSION OF BID. 2. EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND SITE VISITS AND MAY NOT REFLECT EXACT "AS— BUILT" CONDITIONS. FIELD VERIFY EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. COORDINATE NEW WORK AND DEMOLITION WITH OTHER DISCIPLINES AND EXISTING CONDITIONS PRIOR TO CONSTRUCTION. 3. COORDINATE THE INSTALLATION OF THE MECHANICAL SYSTEMS WITH OTHER TRADES TO ENSURE A NEAT AND ORDERLY INSTALLATION. COORDINATE INSTALLATION OF DUCTWORK AND PIPING TO AVOID CONFLICTS WITH ELECTRICAL PANELS, LIGHTING FIXTURES, ETC. 4. AVOID DAMAGING EXISTING SURFACES AND EQUIPMENT TO REMAIN FOR NEW INSTALLATION DURING WORK. REPAIR DAMAGE CAUSED DURING CONSTRUCTION AT NO EXTRA COST TO THE OWNER. 5. ALL MECHANICAL EQUIPMENT SHOWN ON THE MECHANICAL PLANS SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR UNLESS OTHERWISE NOTED. 6. NEW MECHANICAL EQUIPMENT AND DUCTWORK ARE SHOWN AT APPROXIMATE LOCATIONS. FIELD MEASURE FINAL DUCTWORK LOCATIONS PRIOR TO FABRICATION AND MAKE ADJUSTMENTS AS REQUIRED TO FIT THE DUCTWORK WITHIN THE AVAILABLE SPACE. VERIFY THAT FINAL EQUIPMENT LOCATIONS MEET MANUFACTURER'S RECOMMENDATIONS REGARDING SERVICE CLEARANCE AND PROPER AIRFLOW CLEARANCE AROUND EQUIPMENT. 7. REFER TO ARCHITECTURAL DRAWINGS FOR RELATED CONSTRUCTION DETAILS AS APPLICABLE TO THE HVAC SYSTEM. 8. COORDINATE LOCATION OF ROOF MOUNTED HVAC EQUIPMENT AND ROOF PENETRATIONS WITH THE ARCHITECTURAL AND STRUCTURAL DRAWINGS. 9. INSTALL DUCTWORK PARALLEL TO BUILDING COLUMN LINES UNLESS OTHERWISE SHOWN OR NOTED. 10. OVERHEAD HANGERS AND SUPPORTS FOR EQUIPMENT, DUCTWORK AND PIPING SHALL BE FASTENED TO BUILDING JOISTS OR BEAMS. DO NOT ATTACH HANGERS AND SUPPORTS TO THE ABOVE FLOOR SLAB OR ROOF. 11. COORDINATE LOCATION OF EQUIPMENT SUPPORTS WITH LOCATION OF EQUIPMENT ACCESS PANELS /DOORS TO ENABLE SERVICE OF EQUIPMENT AND /OR FILTER REPLACEMENT. 12. SEAL PENETRATIONS THROUGH THE BUILDING COMPONENTS IN ACCORDANCE WITH THE CONTRACT SPECIFICATIONS. FIREPROOF PENETRATIONS THROUGH FIRE RATED COMPONENTS IN ACCORDANCE WITH U.L. REQUIREMENTS. 13. LOCATE AND SET THERMOSTATS FOR WIRING IN CONDUIT UNDER DIVISION 16. VERIFY EXACT LOCATIONS WITH ARCHITECT PRIOR TO INSTALLATION. INSTALL DEVICES 48" AFF TO MEET ADA REQUIREMENTS UNLESS NOTED OTHERWISE ON PLANS. 14. COORDINATE THE LOCATION AND ELEVATION OF WALL — MOUNTED DEVICES WITH PRESENTATION BOARDS, DISPLAY CABINETS, SHELVES OR OTHER COMPONENTS SHOWN ON THE ARCHITECTURAL DRAWINGS THAT ARE TO BE INSTALLED UNDER OTHER DIVISIONS. CONTRACTOR WILL NOT BE REIMBURSED FOR RELOCATION OF WALL — MOUNTED DEVICES CAUSED BY A LACK OF COORDINATION. 15. RIGID DUCTWORK INSULATION: PROVIDE 1 -1/2" THICK, 3 LB DENSITY DUCT LINER IN RECTANGULAR SUPPLY AND RETURN AIR DUCTS. PROVIDE 2" THICK, 3/4 LB DENSITY INSULATION WRAP ON RIGID ROUND, CONCEALED, SUPPLY AND OUTDOOR AIR DUCTS. DUCT SIZES ON MECHANICAL PLANS INDICATE CLEAR INSIDE AIRFLOW DIMENSIONS, INCREASE SHEET METAL SIZES ACCORDINGLY. 16. PROVIDE A NEW SET OF AIR FILTERS IN UNITS PRIOR TO TESTING, ADJUSTING AND BALANCING AND BEFORE TURNING SYSTEM(S) OVER TO OWNER. D0 l ./ RECE V I ,. FEB -- 8 2008 PERMIT CENTEFI HENDERSON ENGINEERS=_ 10370 RICHMOND AVENUE, SUITE 370 HOUSTON, TX 77042 TEL 713 783 7707 FAX 713 783 7797 www.hel- eng.cem 0750001294 R1S 1MH SI M V eki C ISSUED I REVISED DATE 12.17.07 01.03.08 01.11.08 01.25.08 HEALTH DEPT SUBMITTAL 98% OWNER REVIEW HEALTH DEPT RVSNS ISSUED FOR PERMIT MECHANICAL FLOOR PLAN M -1.0 4325 Tam-O-Shanter Way, Dayton, OH 45429 I p 937.47.2334 I info@moda4.00m MODA4 PROJECT NUMBER: 07009 555 Southcenter =PM ..— ..— mom. •• EXIS TING RE 4 E- ■ I I ■••■••■••■ MI • MIMI= _m STORAGE ROOM I,; L! il. min 1 2 4 6 7 8 9 10 MECHANICAL SYMBOLS I NG I E. THIS IS A MASTER LEGEND AND NOT ALL SYMBOLS, ETC. ARE NECESSARILY USED ON THE DRAWINGS. HVAC EQUIPMENT & DUCTWORK NOTE ALL DUCT DIMENSIONS SHOWN ON DRAWINGS ARE INSIDE DIMENSIONS. SEE SECTION 15250 OF THE SPECIFICATION FOR DUCTWORK TO RECEIVE INSULATION OR LINER. Jr L J r RD ® THERMOSTAT EXISTING DUCTWORK OR EQUIPMENT TO REMAIN BRANCH DUCT WITH 45' RECTANGLE —ROUND BRANCH FITTING ELBOW WITH TURNING VANES RETURN, EXHAUST, OR OUTSIDE AIR DUCT UP RETURN, EXHAUST, OR OUTSIDE AIR DUCT DOWN SUPPLY AIR DUCT UP SUPPLY AIR DUCT DOWN EQUIPMENT WITH FLEXIBLE DUCT CONNECTION 10" CSD -1 300 CFM NECK SIZE, TYPE, CFM OF SUPPLY DIFFUSER OR REGISTER MANUAL VOLUME DAMPER SQUARE TO ROUND TRANSITION DUCT MOUNTED SMOKE DETECTOR (SD= SUPPLY /RD= RETURN) ABBREVIATIONS AFF BPS BD CFM DDC DX EA FFA FFB GPM IN WC MAX MBH ABOVE FINISHED FLOOR BUILDING AUTOMATION SYSTEM BACKDRAFT DAMPER CUBIC FEET PER MINUTE DIRECT DIGITAL CONTROL DIRECT EXPANSION EXHAUST AIR FROM FLOOR ABOVE FROM FLOOR BELOW GALLONS PER MINUTE INCHES OF WATER COLUMN MAXIMUM 1000 BTU PER HOUR MC MIN NC OA RA SA SD TFA TFB TYP UNO W/ W/O MECHANICAL CONTRACTOR MINIMUM NOISE CRITERIA OUTSIDE AIR RETURN AIR SUPPLY AIR SMOKE DUCT DETECTOR TO FLOOR ABOVE TO FLOOR BELOW TYPICAL UNLESS NOTED OTHERWISE WITH WITHOUT STANDARD MOUNTING HEIGHTS MECHANICAL THERMOSTATS (USER ADJUSTABLE) CONTROLS (CENTERLINE) (AFF, AFG, UNLESS NOTED OTHERWISE) 48" 48" ANNOTATION MECHANICAL PLAN CALLOUT MECHANICAL EQUIPMENT DESIGNATION (OWNER FURNISHED AND INSTALLED UNLESS NOTED OTHERWISE, RE: M -3.0) CONNECTION POINT OF NEW WORK TO EXISTING DETAIL REFERENCE UPPER NUMBER INDICATES DETAIL NUMBER LOWER NUMBER INDICATES SHEET NUMBER I • i I I I i I I • I REMOTE STOCKROOM MECHANICAL PLAN SCALE: 1 /4" =1' -0" IMAM w I I I ""11. o III I 111 e 0 C MECHANICAL FLOOR PLAN SCALE: 1 /4 " =1' -0" MECHANICAL PLAN NOTES: 1® EXISTING "VENTROL" REFRIGERATION UNIT TO REMAIN. REPAIR /REFURBISH SYSTEM TO "LIKE —NEW" CONDITION. REPLACE EQUIPMENT IF NECESSARY. REPLACE EXISTING "VENTROL" ROOF MOUNTED CONDENSING UNIT WITH NEW AS PROVIDED BY OWNER. ® CONNECT NEW SUPPLY AIR DUCT TO EXISTING 12x12 SUPPLY AIR DUCT FROM SHELL BUILDING SYSTEM. CONNECT NEW EXHAUST AIR DUCT TO EXISTING 8"95 EXHAUST AIR DUCT FROM SHELL BUILDING SYSTEM. ® LOCATE NEW FAN —COIL UNIT AS INDICATED. UNIT, INCLUDING FILTER SECTION, SHALL BE ACCESSIBLE FOR SERVICE FROM A CEILING ACCESS PANEL. SUSPEND UNIT FROM STRUCTURE PER MANUFACTURER'S RECOMMENDATIONS. MOUNT UNIT BETWEEN STRUCTURAL JOISTS AS HIGH AS POSSIBLE WHILE COORDINATING WITH OTHER BUILDING SYSTEMS TO ALLOW WORKING CLEARANCES AS REQUIRED BY CODE AND UNIT MANUFACTURER. RE: 2,3/M -2.0. COORDINATE INSTALLATION OF UNIT SUPPORTS AND PIPING TO MAINTAIN ACCESS AND CLEARANCE FOR FILTER REPLACEMENT. O5 REFER TO PLUMBING DRAWINGS FOR CONDENSATE DRAIN LINES. ® ELECTRICAL CONTRACTOR SHALL PROVIDE A SMOKE DETECTOR IN THE SUPPLY DUCTWORK OF THE FAN —COIL UNIT. SMOKE DETECTOR SHALL BE ACCESSIBLE THRU THE LAY—IN CEILING. RE: 3/M -2.0. ® NEW "VENTROL" REFRIGERATION UNIT WITH REMOTE CONDENSING UNIT PROVIDED BY GODIVA AND INSTALLED BY THE MECHANICAL CONTRACTOR. RE: 1/M -2.0. SUSPEND UNIT FROM STRUCTURE WITH THREADED RODS AND VIBRATION ISOLATORS. ® CONNECT NEW 6 "0 EXHAUST DUCT TO FAN /LIGHT COMBINATION. PROVIDE TRANSITION AS REQUIRED. ® SUPPLY AIR OF VAV BOX INCREASED FROM THAT SHOWN ON SHEEL BUILDING DOCUMENTS TO PROVIDE MINIMUM OUTDOOR AIR REQUIRED BY LOCAL CODES. ROOF TOP UNIT PROVIDING SUPPLY AIR ONLY HAS 18.34% OUTDOOR AIR CAPACITY. GENERAL NEW NOTES: 1. PRIOR TO SUBMITTING BID, VISIT THE JOB SITE AND BECOME FULLY ACQUAINTED WITH THE EXISTING CONDITIONS OF THE PROJECT. REVIEW THE GENERAL NOTES, SPECIFICATIONS AND OTHER DRAWINGS FOR ADDITIONAL REQUIREMENTS WHICH MAY NOT BE SPECIFICALLY CALLED OUT IN THIS PORTION OF THE CONSTRUCTION DOCUMENTS. NOTIFY ARCHITECT AND /OR ENGINEER VIA OWNER OF CONFLICTS OR DISCREPANCIES PRIOR TO SUBMISSION OF BID. 2. EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND SITE VISITS AND MAY NOT REFLECT EXACT "AS— BUILT" CONDITIONS. FIELD VERIFY EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. COORDINATE NEW WORK AND DEMOLITION WITH OTHER DISCIPLINES AND EXISTING CONDITIONS PRIOR TO CONSTRUCTION. 3. COORDINATE THE INSTALLATION OF THE MECHANICAL SYSTEMS WITH OTHER TRADES TO ENSURE A NEAT AND ORDERLY INSTALLATION. COORDINATE INSTALLATION OF DUCTWORK AND PIPING TO AVOID CONFLICTS WITH ELECTRICAL PANELS, LIGHTING FIXTURES, ETC. 4. AVOID DAMAGING EXISTING SURFACES AND EQUIPMENT TO REMAIN FOR NEW INSTALLATION DURING WORK. REPAIR DAMAGE CAUSED DURING CONSTRUCTION AT NO EXTRA COST TO THE OWNER. 5. ALL MECHANICAL EQUIPMENT SHOWN ON THE MECHANICAL PLANS SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR UNLESS OTHERWISE NOTED. 6. NEW MECHANICAL EQUIPMENT AND DUCTWORK ARE SHOWN AT APPROXIMATE LOCATIONS. FIELD MEASURE FINAL DUCTWORK LOCATIONS PRIOR TO FABRICATION AND MAKE ADJUSTMENTS AS REQUIRED TO FIT THE DUCTWORK WITHIN THE AVAILABLE SPACE. VERIFY THAT FINAL EQUIPMENT LOCATIONS MEET MANUFACTURER'S RECOMMENDATIONS REGARDING SERVICE CLEARANCE AND PROPER AIRFLOW CLEARANCE AROUND EQUIPMENT. 7. REFER TO ARCHITECTURAL DRAWINGS FOR RELATED CONSTRUCTION DETAILS AS APPLICABLE TO THE HVAC SYSTEM. 8. COORDINATE LOCATION OF ROOF MOUNTED HVAC EQUIPMENT AND ROOF PENETRATIONS WITH THE ARCHITECTURAL AND STRUCTURAL DRAWINGS. 9. INSTALL DUCTWORK PARALLEL TO BUILDING COLUMN LINES UNLESS OTHERWISE SHOWN OR NOTED. 10. OVERHEAD HANGERS AND SUPPORTS FOR EQUIPMENT, DUCTWORK AND PIPING SHALL BE FASTENED TO BUILDING JOISTS OR BEAMS. DO NOT ATTACH HANGERS AND SUPPORTS TO THE ABOVE FLOOR SLAB OR ROOF. 11. COORDINATE LOCATION OF EQUIPMENT SUPPORTS WITH LOCATION OF EQUIPMENT ACCESS PANELS /DOORS TO ENABLE SERVICE OF EQUIPMENT AND /OR FILTER REPLACEMENT. 12. SEAL PENETRATIONS THROUGH THE BUILDING COMPONENTS IN ACCORDANCE WITH THE CONTRACT SPECIFICATIONS. FIREPROOF PENETRATIONS THROUGH FIRE RATED COMPONENTS IN ACCORDANCE WITH U.L. REQUIREMENTS. 13. LOCATE AND SET THERMOSTATS FOR WIRING IN CONDUIT UNDER DIVISION 16. VERIFY EXACT LOCATIONS WITH ARCHITECT PRIOR TO INSTALLATION. INSTALL DEVICES 48" AFF TO MEET ADA REQUIREMENTS UNLESS NOTED OTHERWISE ON PLANS. 14. COORDINATE THE LOCATION AND ELEVATION OF WALL — MOUNTED DEVICES WITH PRESENTATION BOARDS, DISPLAY CABINETS, SHELVES OR OTHER COMPONENTS SHOWN ON THE ARCHITECTURAL DRAWINGS THAT ARE TO BE INSTALLED UNDER OTHER DIVISIONS. CONTRACTOR WILL NOT BE REIMBURSED FOR RELOCATION OF WALL — MOUNTED DEVICES CAUSED BY A LACK OF COORDINATION. 15. RIGID DUCTWORK INSULATION: PROVIDE 1 -1/2" THICK, 3 LB DENSITY DUCT LINER IN RECTANGULAR SUPPLY AND RETURN AIR DUCTS. PROVIDE 2" THICK, 3/4 LB DENSITY INSULATION WRAP ON RIGID ROUND, CONCEALED, SUPPLY AND OUTDOOR AIR DUCTS. DUCT SIZES ON MECHANICAL PLANS INDICATE CLEAR INSIDE AIRFLOW DIMENSIONS, INCREASE SHEET METAL SIZES ACCORDINGLY. 16. PROVIDE A NEW SET OF AIR FILTERS IN UNITS PRIOR TO TESTING, ADJUSTING AND BALANCING AND BEFORE TURNING SYSTEM(S) OVER TO OWNER. D0 l ./ RECE V I ,. FEB -- 8 2008 PERMIT CENTEFI HENDERSON ENGINEERS=_ 10370 RICHMOND AVENUE, SUITE 370 HOUSTON, TX 77042 TEL 713 783 7707 FAX 713 783 7797 www.hel- eng.cem 0750001294 R1S 1MH SI M V eki C ISSUED I REVISED DATE 12.17.07 01.03.08 01.11.08 01.25.08 HEALTH DEPT SUBMITTAL 98% OWNER REVIEW HEALTH DEPT RVSNS ISSUED FOR PERMIT MECHANICAL FLOOR PLAN M -1.0 4325 Tam-O-Shanter Way, Dayton, OH 45429 I p 937.47.2334 I info@moda4.00m MODA4 PROJECT NUMBER: 07009 555 Southcenter 1 6 7 8 9 10 i • • I • a r , - - •- le MI L L I. • . i 1 • • _L. ▪ T__ W.-. •■• _.a _ • • .. 1 .• ; . 6 •• • 1 p • 9 _ I ' II I ▪ I • . n . i.• 1a.9�e ■■• • — _. J • 4 • • 1 I%1 1 1 7 1 191111 1111 1• • • • • • • ISI 1_L1 ••1__••■■■■•■■•__.J •-• • .. •- 1 1 1 .1 •I. 1 ._.__. : • -- - - •1 - 1 . - 1 1 7 1 1 ®L • 14 LI fg I6 E •• ... • • •1 I '1 I II . 1 1 .__.__._. 1 • 1;:.:.... a •.rr•.•r • -- • -- • - 6.-- • -- • - - --- • F 30100 RA I - • 1.161 LI t-414"--1-7 LIP TO is I ere III 11L1 14. LI i_6___ — •••L 1 • • I_ I ' • • • • ▪ I " _t F I • • • • • • • 141 ; •- • ,. • 9 • I- 1 9._ • •••• — __._ ®__19Fl9 PI 191J61J_I •__ — _— _— ___F19 • • • • • • • 'I.. • IIIRM•Ma•Mil•i•/■Cla ▪ sea • 1, 1 • • • • • • • • • • • API IFI IAII 1_14_1 •__ •rI • A . ▪ ' I I II ws 11 O • • • • • .. - 7 I ▪ •1 1 16 ▪ .__..1!._ awa._.a• •_.._ • "LAC:iA - r17 <1 PIEL .r.-- .._.__!_ 11LLJ61_6 �1 1950 1,_. 1171 I 14 141 1J_1_- • .-- wa--- - ---_I- ILIJLIer _ LJ_I4 d__ — ® __._ =KB _ 1 •'r, • •1- 1 11••Ytl.1I tl • 1 . °--- '- -. }__. ._. rs f.:aS:4^ •- lad -Waal - --_- -- -• I 'PI 11II 111 1J •p _ 4x • I 1111 111 IILIJ•1__L ..._ _— _.__.__ —__ 9rmarseILIJ6 78x14 - - -- °°r•m•% I P J L I ✓ , 1 4 ®� EL - 9r1IFIULI •ZIJJ _1171 ___.__.__ — — _ _— 7 7 7 1 7 1 IF1 1111 IJL 1 11.1 16 1.117. 4l_ 111 ._1 ...._1 ._. —_IJ_L • • E SGI 17 LIJ•IJ61- 1M MR RI d®I4LIJL1•g..I -L • i" 7. m w I d . 5".1 I 4 " -I1PI1 I ®11 • • • • • o 1 r✓. `� • . _ . . • tl • • • • • • I • • • • • • • • • • • • • • • • • • • • • • 1 I. • 1 C.1 . 1. • .L.__•__•.....•_• •-tea. Ire InI I.I IJl loam Lam PI aIX RV 1 I•1 2 4 1 ! 1 4 24x24 • •_• •• • •• • • . I. •..• •..• 1 • 1 •I • • • al d • MECHANICAL FLOOR PLAN SCALE: 1 /8 " =1' -0" 18x1& EC7I 60P SQ k:t a . __ .__.__.__._•._. II . 1•_Iltil_ II II 1 .1 II II II 4 II II II II II IQ I I 11 9 11 I8 11 II II II 47 .11 n I 1 I — - -LA_ diir.i — REE1 — • • .1 ._.._• ._.._ —_.._• •■■•■■••• •_• 1$ O6 E716 CCI -50 • z• -11 1 "1 �.* 1 JP • _ -- _I_•••_p••!_! I. 6 L I • 1 I 1 9 I •1 • :1 "1" • IJLIJLI_1_ —_ . — MECHANICAL PLAN NOTES: O ROUTE REFRIGERANT PIPING IN THE CEILING PLENUM AS INDICATED. PIPING SHALL BE INSTALLED PERPENDICULAR TO BUILDING LINES IN AN ORDERLY MANNER. RE: 9/M -2.0. COORDINATE EXACT ROUTING WITH MALL'S TENANT COORDINATOR PRIOR TO BID. O ROUTE REFRIGERANT PIPING UP THRU TENANT ABOVE NEAR COLUMN LINE AS INDICATED. COORDINATE EXACT ROUTING WITH MALL'S TENANT COORDINATOR PRIOR TO BID. O ROUTE REFRIGERANT PIPING IN THE CEILING PLENUM OF THE SECOND FLOOR TENANT AS INDICATED. PIPING SHALL BE INSTALLED PERPENDICULAR TO BUILDING LINES IN AN ORDERLY MANNER. RE: 9/M -2.0. COORDINATE EXACT ROUTING WITH MALL'S TENANT COORDINATOR PRIOR TO BID. • • 1 1111 161 IFI " 1JL1®811JLJJL64_ .■ _ SHELL BUILDING AND ADJACENT TENANT'S SHOWN FOR REFERENCE ONLY. CONTRACTOR RESPONSIBLE FOR FIELD COORDINATING EXACT REFRIGERANT PIPE ROUTING WITH LANDLORD'S TENANT COORDINATOR PRIOR TO BID. CONTRACTOR WILL NOT BE COMPENSATED FOR ADJUSTMENTS TO ROUTING NECESSITATED BY AN UNCOORDINATED BID. I INSTALL ALL PIPING TIGHT TO STRUCTURE. ALL WORK ABOVE ADJACENT TENANTS TO BE PERFORMED AFTER NORMAL OPERATING HOURS. --011 FEB-8 2008 PERMIT CENTER HENDERSON ENGINEERSN 10370 RICHMOND AVENUE, SUITE 370 HOUSTON, TX 77042 TEL 713 783 7707 FAX 713 783 7797 www.hei eeg.r.om 0750001294 RJS JMH SI.M MX17. 11/07 t• MERE 4134 Co) c..) v ° 0 ISSUED / REVISED DATE HEALTH DEPT SUBMITTAL 98% OWNER REVIEW HEALTH DEPT RVSNS ISSUED FOR PERMIT 12.17.07 01.03.08 01.11.08 01.25.08 MECHANICAL OVERALL FLOOR PLAN M -1.1 1 _°••_•••■•■•-,_••r•_• B__ I _I lamp • - rl ° 1 1 l • r - i I • •°w•___^_•w_•_• • •r 1°11_••1 ■_• •• •.•• • • .ramp= W._,.•r•,�w.�� .`_. •• •__.._• —17• I 1 - 1 gr! Ir1 1l11 141 11,1 I Iila_ l■_■_ GT) tl • • 1••11. •• •__•r_• ••• ._•._•_r•__• 11_.•• 9 ti • • 1 — t 1 IN 1 It III I. LI •.1L 1 I•r 1 -1 oral 111 1111 I • B 1 -I • 194, I'9. •a I, •••••■• ... ^••LI -• _•_ -1 • • • - I__- S • • ml • • • I 1 I I ._ se • , Spam. •_S. •am _ai '. • 11 VI • • • • • • • PM 1 IMP I II • • • • • ,a4• 1 -- 1 1 1 -I IrI Il / 1 ®1 1 1_1 11I.I Idt II • •_••_ °••_••a•l_ • • • • • • • • • • • • • tlr!__ 1111 •_• ••"•[• 2 • i J e Ir N _ °O lI l - • • • • • • • • • I ••■• Ir sr I • ral Ir i A 11 t• 1 °1 1111 VII I r 10 1� I I Apr 1 I- -- ,5_•_.a. e .. • • • • • • • 11x1 ILI ILI ILI_L • • • • • • • �r 1 •,•11Y - ..1•__•_WI •wr...a• •r2 • i.e. •• I : 4A9 • • I I1 II III 11s3 NMI • • • • • 1 RP • • i • • ° r. • • I • Ins • •^^._ ^•_•___I •_I 1 - 1 III 1• I ILI 1_1 1_ rl_ 1___•_ rrr_•__• r .a.w__•__• °r•_r•w_a° °"__•r_•r_- • • • • • I_d • •B . •. I • - 1 1 •• 1 I I •• 1._ 1 •• 1 ._I I . •_ _•S_•a•_•_. Ram I I •• - I .1 I ,. a • . •• ._• •Lr • •_•wrm_•a•_._. _a ■__.^_ ®_r,r_••• Rat %• I s r aI • •r• I _ LI • L • i .I o r •r L • • • 1 r 1 r• • • e PP a a • L I' • 6 . I 1 11 1 ,• • •• I r•r. r • • • •_• • r a o • RINE • r_r _• r r ^11••1- •1:11r1 .1 _•__ •W_1__r•S•__• I •1 ERIE ti _ L 1 1 I - �. ._;,^_prr•rr• pampa 1 I.1_arrr•1� rte_ __• • .- L • • t tl L WI r. • L. • • Ng . e _I•L • d •• Ira - . ,T • I I °11• t 1 _•S r.rr•4rI erg 1 • IRr' • • I • • fl'•_ ti • • I I i• MRI as .+q Y1'II • IMO • r OIR ill PR r 1- •a � 4 - F ■ _n•.•_B__••••.^a.•_IO °I °•_ II 1 • VI 0116r•■■■•■•-411011.1.•-- --. I I • • d I L ••L •- -• - -•° - -•Y —•_ - -- It r1I- 111IIIII • • II ti 9 1 .. . III IJI I_LI_L#__.•®r_• •_•__ I. • k:9 • 1 • • MECHANICAL ROOF PLAN SCALE: 1 /8 " =1' —O" • • • • • . ° 1 In I ILI 1_1 •_I I_ 1. 1_•_ r• r_••■•■■••••••rm•rr.__e_._a.••__•__•_____ I °1 1_1 1 .1I 111.LI I_1 S,_rr__•___•__.a•^_ • •- •1 • II III Ji •• I I •r_.__ • •• •__ _•_IR •__._•r.__•_ • -I ____am__•__ ___ _•_ •r•___I_I I 1 111.1 .1_1__I__mm0 • r^ 1 I •• •_• •_. ••• B_ -•- 1 - 1 I °I r .r• ._._••9__. SS •_ - r- ""•1°b,•r11i 11 e •I I •.. •• • • :.I. • r , : _ .W ag • al `lFa •r II 1 I•I _i_I__•rrma^ • S•_ ti I IL • • " 1 I' I 'tl. •_, •r• •••__•___ • ._ _B •r•__• •_• •_. • I S. • • 1 'I• d • • 6 114 .11.1.11 I9LId• Ia:. • I__ •• • • • • •_, • .. • •• I •• •. • _••_••X. • •• • ••• • • • • • • • • rl 11'1 ILIJ9 . 1_I - ._ -. L- r • • • •_•• ^s_ BasS r_•__•__•_ -_.4 -•• .•. • • .ri - •••_ ••• • . l I 11 •••• 191 ILI 1. • 1 • 1. • 1_•1•_•rr : __• °- .__m__ • 1 I. I. . . . . . . . . . . . . . I • I r ll • •1 I Ill .. S - I-- •-- •--• -_ •-- •- -.._ • • • -T r ••• _• •- 1 1 • • Mal aa MIR I. -1 a_ Yea FL 1 I 1 _ r• II II • II •. I I i Awe • • • • • • 111.1 IPA Nril 1•01 • • • • • • • • • • • • • • • • • • • • • • • a walla...Ey • • • • 2 I- • • taloa SHELL BUILDING SHOWN FOR REFERENCE ONLY. CONTRACTOR RESPONSIBLE FOR FIELD COORDINATING EXACT CONDENSING UNIT LOCATION WITH LANDLORD'S TENANT COORDINATOR PRIOR TO BID. CONTRACTOR WILL NOT BE COMPENSATED FOR ADJUSTMENTS TO THE INSTALLATION NECESSITATED BY AN UNCOORDINATED BID. MECHANICAL GENERL NOTES: ALL TENANT EQUIPMENT LOCATED ON THE ROOF SHALL INCLUDE A PHENOLIC LAKE STATING THE TENANT'S NAME AND SPACE NUMBER. 2. TENANT'S CONTRACTOR SHALL ARRANGE WITH LANDLORD'S APPROVED ROOFING CONTRACTOR TO INSTALL WALKWAYS AROUND ALL ROOFTOP MOUNTED HVAC EQUIPMENT AT TENANT'S EXPENSE. 3. ALL WORK ON THE ROOF AND ANY PENETRATIONS OF THE ROOF TO BE PERFORMED BY THE LANDLORD'S APPROVED ROOFING CONTRACTOR AT THE TENANT'S EXPENSE. MECHANICAL PLAN NOTES: 0 REMOTE NENTROL" CONDENSING UNIT TO BE INSTALLED ON NEW EQUIPMENT RAILS ON THE ROOF. FIELD COORDINATE REMOTE CONDENSER LOCATION TO MAINTAIN WORKING CLEARANCES AS REQUIRED BY CODE AND UNfT MANUFACTURER. ALL HORIZONTAL EXTERIOR REFRIGERANT PIPING RUNS SHALL BE SUPPORTED FROM WALLS OR SET ON WOOD BLOCKS TO BE KEPT OFF THE ROOF. RE: 10/M-2.0. PIPING SHALL BE INSTALLED PERPENDICULAR TO BUILDING LINES IN AN ORDERLY MANNER. 0 PROVIDE NEW CONDENSING UNIT AND INSTALL ON NEW EQUIPMENT RAILS ON THE ROOF. FIELD COORDINATE REMOTE CONDENSER LOCATION TO MAINTAIN WORKING CLEARANCES AS REQUIRED BY CODE AND UNIT MANUFACTURER. ALL HORIZONTAL EXTERIOR REFRIGERANT PIPING RUNS SHALL BE SUPPORTED FROM WALLS OR SET ON WOOD BLOCKS TO BE KEPT OFF THE ROOF. RE: 10/M-2.0. PIPING SHALL BE INSTALLED PERPENDICULAR TO BUILDING LINES IN AN ORDERLY MANNER. PROVIDE SINGLE THRU ROOF PENETRATION SYSTEM FOR BOTH SETS OF REFRIGERANT LINES SIMILAR TO PORTALS PLUS ALU M I—FLASH SYSTEM WITH C-481 CAP. FLASH INTO ROOFING SYSTEM AND SEAL WATERTIGHT. ?Y 011 ft e RECEIVFT PERMIT CENTr_ HENDERSON 10370 RICHMOND AVENUE, SUR 370 HOUSTON, IX 77042 TEL 713 783 7707 FAX 713 783 7797 www.hei 0750001294 6 7 8 4 ele Di ILI o 0 • EXP. 11/07/08 L.) co co co c`l ISSUED I REVISED DATE HEALTH DEPT SUBMITTAL 1117.07 98% OWNER REVIEW 01.03.08 HEALTH DEPT RVSNS 01.11.08 ISSUED FOR PERMIT 01.25.08 MECHANICAL OVERALL ROOF PLAN M-1 .2 V V DUCT SIZE U L_ r w _....- N U D a n n n 1 2 3 4 5 6 7 6 9 10 T.G.C. TO SUPPLY AND INSTALL 1/2" ALL — THREAD ROD. HUMIDISTAT SUPPLIED AND INSTALLED BY GODIVA NOTES: 1. THE VENTROL SYSTEM AS SHOWN IS SUPPLIED FACTORY PREASSEMBLED WITH PRE —SET CONTROLS. 2. T.G.C. TO INSTALL THE BLOWER SECTION IN STOCKROOM AS SHOWN ON PLANS. 3. T.G.C. TO PROVIDE POWER WIRING TO BOTH UNITS, PRIMARY AND SECONDARY. 4. T.G.C. TO INSTALL THERMOSTAT AT LOCATION ON PLANS AND PROVIDE CONTROL WIRING AS SHOWN. 5. T.G.C. TO PROVIDE CONDENSATE PIPING. 6. T.G.C. TO CHECK, TEST AND START UP. 7. T.G.C. TO PROVIDE REFRIGERANT PIPING BETWEEN CONDENSING UNIT AND BLOWERS. VENTROL SYSTEM (FURNISHED BY GODIVA) NO SCALE GRIP LOCK WOVEN NYLON/ POLYESTER BLEND FLEXIBLE CONNECTION MAXIMUM 6" (SIMILAR TO METAL —FAB BY DURO DYNE) OVERLAP DUCT WRAP INSULATION AND SEAL EXTERNAL INSULATION IF NOT INTERNALLY LINED ---1 PROVIDE LINED RETURN AIR BOOT FULL SIZE OF BOX RETURN AIR OPENING OR AS INDICATED ON PLANS. BOOT MAY BE STRAIGHT OR "L" SHAPED AS SHOWN 5' MIN. LENGTH LINE OF SOUND PROVIDE OR RELOCATE FILTER RACK AS REQ'D. SQUARE TO ROUND L VENTROL CONDENSING UNIT SUPPLIED IN A DOG HOUSE WIRED WITH, CLARK CASE HEATER AND FAN CYCLING SWITCH. MOUNT ON ROOF VERIFY LOCATION WITH LANDLORD. IIIIIIIIIIIIIIIIIIIIIIIIIIIIII C> SUPPLY DUCT PILOT LIGHT, FAN SWITCH AND LIMIT CONTROL SUPPLIED AND INSTALLED BY GODIVA 4 - SUPPLY DUCT 7 EVAPORATOR SECTION (TYPICAL FOR 2) PEERLESS BLOWER COIL 115V -1 -60 24 HR. SUPPLIED BY GODIVA INSTALLED BY T.G.C. TEMP. CONTROL SUPPLIED BY PARISI, INSTALLED BY T.G.C. SHIPPED LOOSE AND WALL MOUNTED PER PLANS. CONNECT TO PRESSURE CONTROL. SEE WIRING DIAGRAM ON VENTROL DWG. T.G.C. TO PROVIDE COPPER /PVC PIPING FOR CONDENSATE RUN TO DRAIN AS REQUIRED ELECTRIC REHEAT COIL SERIES FAN (SEE NOTE 1) ACTUATOR ALLOW FOR REQUIRED L NEC CLEARANCE. DAMPER CONTROLLER BOX FLOW METERING STATION MINIMUM STRAIGHT LENGTH OF 3X DUCT DIAMETER TAKE —OFF FITTING J INSULATION AS REQUIRED (EXTERNAL SHOWN) NOTES: 1. SUPPORT AIR TERMINAL UNIT, BOTH ENDS WITH MINIMUM 2" WIDE GALVANIZED 22 GA. HANGER STRAPS. SUPPORT UNIT WITH SPRING VIBRATION ISOLATORS WITH 0.5 STATIC DEFLECTION IF INTERNAL FAN SPRING ISOLATION IS NOT PROVIDED. LOCATE SUPPORTS AROUND UNIT TO MAINTAIN CLEARANCE FOR ACCESS TO UNIT COMPONENTS 2. INSTALL BOX NOT MORE THAN 3 FEET ABOVE THE CEILING TO ENABLE ACCESS FOR MAINTENANCE. SERIES FAN POWERED VAV BOX WITH ELECTRIC REHEAT COIL NO SCALE CONDENSING UNIT L J INTEGRAL FILTER DRIER NOTES: 1. PROVIDE REFRIGERANT TRAP(S) AS REQUIRED BY MANUFACTURER. 2. VERIFY PIPE SIZES REQUIRED WITH EQUIPMENT SUPPLIER. 3. PITCH SUCTION LINE TOWARDS CONDENSING UNIT. 4. SIGHT GLASS SHALL BE FULL LINE SIZE AND INSTALLED IN THE LIQUID LINE. 5. LOCATE TEV BULB 45' ABOVE CENTERLINE OF PIPE. PLATE WASHER D REFRIGERANT PIPING DETAIL WITH COIL BELOW CU (5 TONS AND LESS) NO SCALE CONNECT TO SUPPORTING STRUCTURAL MEMBER DUCT SIZE TRANSVERSE BRACE 1/4" MAX TRANSVERSE HANGER BRACING DETAIL NO SCALE DOUBLE HANGER SEISMIC CABLE BRACING FOR ROUND DUCTS UP TO 84" NO SCALE LOOT SERVICE VALVE (TYPICAL) REFRIGERANT TRAP TRANSVERSE CABLE BRACE SHEET METAL STRAP (MIN 2 -1/2 "x12 GA. STRAP) LONGITUDINAL CABLE BRACE I CONNECT TO SUPPORTING STRUCTURAL MEMBER SECURE PIPE HANGER TO STRUCTURE THREADED STEEL ROD WITH NUT AND WASHER BOTH SIDES SIGHT GLASS REFRIGERANT LIQUID LINE - REFRIGERANT SUCTION LINE CLEVIS HANGER PIPE WITH INSULATION LONGITUDINAL g il I - A. CABLE BRACE 3" LONG ANGLE PLATE WASHER LONGITUDINAL HANGER BRACING DETAIL NO SCALE PIPE SADDLE WITH HIGH DENSITY INSULATION, RE: SPECIFICATIONS INSULATED PIPE WITH VAPOR BARRIER SHALL BE PROVIDED WITH INSULATION SHIELD CLEVIS PIPE HANGER DETAIL NO SCALE THERMAL EXPANSION VALVE (TEV) TYP CAL l iii I i'�II I! EVAPORATOR COIL LONGITUDINAL BRACES NOTES: 1. EXTEND RIGID METAL DUCT SO THAT MAXIMUM FLEXIBLE DUCT LENGTH DOES NOT EXCEED 5' -0 ". PROVIDE RIGID 90' ELBOW WHERE REQUIRED TO KEEP FLEXIBLE DUCT WITHIN 5' -0" LENGTH LIMITATION. REFRIGERANT LIQUID LINE PROVIDE 4" SECTION OF INSULATION AT BLOCKING BASE FOR LIQUID LINE INSULATED REFRIGERANT SUCTION LINE GALVANIZED PIPE CLAMP (TYP.) FLEX CONNECTION SMOKE DECTECTOR COORDINATE WITH ELECTRICAL. (TYP.) S/A DUCT REFER TO COIL PIPING DETAIL NOTE 3 NOTE 2 STEEL CHANNEL OR UNISTRUT STEEL ANGLE OR UNISTRUT PROVIDE AUXILIARY DRAIN PAN BENEATH FAN COIL UNIT. PAN SHALL BE 3" LARGER THAN UNIT ON EACH SIDE FOIL TAPE AT INSULATION JOINT SEE NOTE 1. CEILING DIFFUSER CEILING ACCESSIBLE FILTER SECTION NOTES: 1. PROVIDE MISCELLANEOUS GALVANIZED SUPPORT ANGLE OR CHANNEL AS REQUIRED TO BRIDGE STRUCTURE 2. SUSPEND DRAIN PAN WITH SUPPORT RODS WHEN ATTACHED TO BUILDING STRUCTURE. 3. ATTACH TO STRUCTURE WITH VIBRATION ISOLATION. FAN -COIL UNIT MOUNTING NO SCALE METAL BAND OVER INSULATION (TYPICAL) HIGH EFFICIENCY TAKEOFF, EXTERNALLY INSULATED COORDINATE BOX —OUT LOCATIONS FOR ALL DRYWALL MOUNTED AIR DEVICES WITH GENERAL CONTRACTOR AND CEILING FRAMING. CEILING DIFFUSER DETAIL NO SCALE 'Dg - D11 PIPE SADDLE (TYP.) 4 "x4 "x12" LONG MIN. TREATED WOOD BLOCK NOTE: PROVIDE SUPPORTS AT 3' -0" ON CENTERS AND WITHIN 1' -0" OF ALL CHANGES IN PIPE DIRECTION. REFRIGERANT PIPING SUPPORT ON ROOF NO SCALE REFER TO PLUMBING PLANS FOR PRIMARY AND SECONDARY DRAIN LINES. INSULATED DUCT VOLUME DAMPER AND LOCK WITH EXTENSION ANCHOR BOLT ROD BRACING (TYP 4 SIDES) SUSPENDED EQUIPMENT DETAIL A SUSPENDED EQUIPMENT WITH VIBRATION MOUNT DETAIL C NOTES: SEISMIC SUPPORT NO SCALE NOTES: TRANSVERSE BRACE CONNECT TO SUPPORTING , CONNECT TO SUPPORTING STRUCTURAL MEMBER SHEETMETAL DUCT VIBRATION ISOLATION 1/2" CLEARANCE MAXIMUM �� \ \ RANCE MAXIMUM VERTICAL HANGER LONGITUDINAL HANGER ONE EACH SIDE OF DUCT { HORIZONTAL BRACE CL BOLTS EQUAL Q OF ANGLES 1" TYPICAL 4 SIDES STRUCTURAL MEMBER INSULATION WHERE REQUIRED 1. CABLE BRACES MAY BE USED FOR SEISMIC RESTRAINT IN LIEU OF ANGLE BRACES. J 45' HIGH EFFICIENCY TAKE —OFF WITH SQUARE TO ROUND FITTING CENTER SEISMIC BRACING 4 FOR RECTANGULAR DUCTS NO SCALE 1. CUT OPENING IN SHEETMETAL DUCT ACCURATELY. INSTALL 45' LATERAL TO AVOID VISIBLE OPENINGS AND SECURE FITTING SUITABLY FOR PRESSURE CLASS. `.„ •� SUPPORT •\ FRAMING ALTERNATE • • LOCATION �• OF BRACE • (TYP 4 CORNERS) HANGER ROD NOTE: PROVIDE GREY OR ALUMINIZED DUCT TAPE SECURING EXTERNAL DUCT INSULATION 45 °LATERAL FLEXIBLE DUCT TAKE OFF DETAIL NO SCALE VIBRATION MOUNT WHERE APPLICABLE DIAGONAL BRACING (TYP. 4 SIDES) LOCK NUT BRACE FRAMING GAP ANGLE WITH RESILIENT PAD (TYP EACH CORNER) NOTES: 1.CABLE BRACES MAY BE USED RESTRAINT IN LIEU OF ANGLE DIAGONAL BRACING (TYP 4 SIDES) SUSPENDED EQUIPMENT DETAIL B FOR SEISMIC BRACES. DETAIL FOR HUNG EQUIPMENT FASTEN TO STRUCTURE 1" BAND CLAMP CONNECT TO AIR DEVICE NECK UNLESS OTHERWISE NOTED. SAME SIZE AS DIFFUSER NECK. RECEIVED FEB - 8 2008 PERMIT CENTER HENDERSON ENGINEERS= 10370 RICHMOND AVENUE, SUITE 370 HOUSTON, TX 77042 TEL 713 783 7707 FAX 713 783 7797 www.hei- eng.com 0750001294 RJS JMH SLM ISSUED/REVISED DATE HEALTH DEPT SUBMITTAL 12.17.07 98% OWNER REVIEW 01.03.08 HEALTH DEPT RVSNS 01.11.08 ISSUED FOR PERMIT 01.25.08 MCP. 11/97/08 J J M -2.0 N 0 0 U) MECHANICAL DETAILS 1 r L_ r L J 1 2 3 4 5 6 7 6 9 10 T.G.C. TO SUPPLY AND INSTALL 1/2" ALL — THREAD ROD. HUMIDISTAT SUPPLIED AND INSTALLED BY GODIVA NOTES: 1. THE VENTROL SYSTEM AS SHOWN IS SUPPLIED FACTORY PREASSEMBLED WITH PRE —SET CONTROLS. 2. T.G.C. TO INSTALL THE BLOWER SECTION IN STOCKROOM AS SHOWN ON PLANS. 3. T.G.C. TO PROVIDE POWER WIRING TO BOTH UNITS, PRIMARY AND SECONDARY. 4. T.G.C. TO INSTALL THERMOSTAT AT LOCATION ON PLANS AND PROVIDE CONTROL WIRING AS SHOWN. 5. T.G.C. TO PROVIDE CONDENSATE PIPING. 6. T.G.C. TO CHECK, TEST AND START UP. 7. T.G.C. TO PROVIDE REFRIGERANT PIPING BETWEEN CONDENSING UNIT AND BLOWERS. VENTROL SYSTEM (FURNISHED BY GODIVA) NO SCALE GRIP LOCK WOVEN NYLON/ POLYESTER BLEND FLEXIBLE CONNECTION MAXIMUM 6" (SIMILAR TO METAL —FAB BY DURO DYNE) OVERLAP DUCT WRAP INSULATION AND SEAL EXTERNAL INSULATION IF NOT INTERNALLY LINED ---1 PROVIDE LINED RETURN AIR BOOT FULL SIZE OF BOX RETURN AIR OPENING OR AS INDICATED ON PLANS. BOOT MAY BE STRAIGHT OR "L" SHAPED AS SHOWN 5' MIN. LENGTH LINE OF SOUND PROVIDE OR RELOCATE FILTER RACK AS REQ'D. SQUARE TO ROUND L VENTROL CONDENSING UNIT SUPPLIED IN A DOG HOUSE WIRED WITH, CLARK CASE HEATER AND FAN CYCLING SWITCH. MOUNT ON ROOF VERIFY LOCATION WITH LANDLORD. IIIIIIIIIIIIIIIIIIIIIIIIIIIIII C> SUPPLY DUCT PILOT LIGHT, FAN SWITCH AND LIMIT CONTROL SUPPLIED AND INSTALLED BY GODIVA 4 - SUPPLY DUCT 7 EVAPORATOR SECTION (TYPICAL FOR 2) PEERLESS BLOWER COIL 115V -1 -60 24 HR. SUPPLIED BY GODIVA INSTALLED BY T.G.C. TEMP. CONTROL SUPPLIED BY PARISI, INSTALLED BY T.G.C. SHIPPED LOOSE AND WALL MOUNTED PER PLANS. CONNECT TO PRESSURE CONTROL. SEE WIRING DIAGRAM ON VENTROL DWG. T.G.C. TO PROVIDE COPPER /PVC PIPING FOR CONDENSATE RUN TO DRAIN AS REQUIRED ELECTRIC REHEAT COIL SERIES FAN (SEE NOTE 1) ACTUATOR ALLOW FOR REQUIRED L NEC CLEARANCE. DAMPER CONTROLLER BOX FLOW METERING STATION MINIMUM STRAIGHT LENGTH OF 3X DUCT DIAMETER TAKE —OFF FITTING J INSULATION AS REQUIRED (EXTERNAL SHOWN) NOTES: 1. SUPPORT AIR TERMINAL UNIT, BOTH ENDS WITH MINIMUM 2" WIDE GALVANIZED 22 GA. HANGER STRAPS. SUPPORT UNIT WITH SPRING VIBRATION ISOLATORS WITH 0.5 STATIC DEFLECTION IF INTERNAL FAN SPRING ISOLATION IS NOT PROVIDED. LOCATE SUPPORTS AROUND UNIT TO MAINTAIN CLEARANCE FOR ACCESS TO UNIT COMPONENTS 2. INSTALL BOX NOT MORE THAN 3 FEET ABOVE THE CEILING TO ENABLE ACCESS FOR MAINTENANCE. SERIES FAN POWERED VAV BOX WITH ELECTRIC REHEAT COIL NO SCALE CONDENSING UNIT L J INTEGRAL FILTER DRIER NOTES: 1. PROVIDE REFRIGERANT TRAP(S) AS REQUIRED BY MANUFACTURER. 2. VERIFY PIPE SIZES REQUIRED WITH EQUIPMENT SUPPLIER. 3. PITCH SUCTION LINE TOWARDS CONDENSING UNIT. 4. SIGHT GLASS SHALL BE FULL LINE SIZE AND INSTALLED IN THE LIQUID LINE. 5. LOCATE TEV BULB 45' ABOVE CENTERLINE OF PIPE. PLATE WASHER D REFRIGERANT PIPING DETAIL WITH COIL BELOW CU (5 TONS AND LESS) NO SCALE CONNECT TO SUPPORTING STRUCTURAL MEMBER DUCT SIZE TRANSVERSE BRACE 1/4" MAX TRANSVERSE HANGER BRACING DETAIL NO SCALE DOUBLE HANGER SEISMIC CABLE BRACING FOR ROUND DUCTS UP TO 84" NO SCALE LOOT SERVICE VALVE (TYPICAL) REFRIGERANT TRAP TRANSVERSE CABLE BRACE SHEET METAL STRAP (MIN 2 -1/2 "x12 GA. STRAP) LONGITUDINAL CABLE BRACE I CONNECT TO SUPPORTING STRUCTURAL MEMBER SECURE PIPE HANGER TO STRUCTURE THREADED STEEL ROD WITH NUT AND WASHER BOTH SIDES SIGHT GLASS REFRIGERANT LIQUID LINE - REFRIGERANT SUCTION LINE CLEVIS HANGER PIPE WITH INSULATION LONGITUDINAL g il I - A. CABLE BRACE 3" LONG ANGLE PLATE WASHER LONGITUDINAL HANGER BRACING DETAIL NO SCALE PIPE SADDLE WITH HIGH DENSITY INSULATION, RE: SPECIFICATIONS INSULATED PIPE WITH VAPOR BARRIER SHALL BE PROVIDED WITH INSULATION SHIELD CLEVIS PIPE HANGER DETAIL NO SCALE THERMAL EXPANSION VALVE (TEV) TYP CAL l iii I i'�II I! EVAPORATOR COIL LONGITUDINAL BRACES NOTES: 1. EXTEND RIGID METAL DUCT SO THAT MAXIMUM FLEXIBLE DUCT LENGTH DOES NOT EXCEED 5' -0 ". PROVIDE RIGID 90' ELBOW WHERE REQUIRED TO KEEP FLEXIBLE DUCT WITHIN 5' -0" LENGTH LIMITATION. REFRIGERANT LIQUID LINE PROVIDE 4" SECTION OF INSULATION AT BLOCKING BASE FOR LIQUID LINE INSULATED REFRIGERANT SUCTION LINE GALVANIZED PIPE CLAMP (TYP.) FLEX CONNECTION SMOKE DECTECTOR COORDINATE WITH ELECTRICAL. (TYP.) S/A DUCT REFER TO COIL PIPING DETAIL NOTE 3 NOTE 2 STEEL CHANNEL OR UNISTRUT STEEL ANGLE OR UNISTRUT PROVIDE AUXILIARY DRAIN PAN BENEATH FAN COIL UNIT. PAN SHALL BE 3" LARGER THAN UNIT ON EACH SIDE FOIL TAPE AT INSULATION JOINT SEE NOTE 1. CEILING DIFFUSER CEILING ACCESSIBLE FILTER SECTION NOTES: 1. PROVIDE MISCELLANEOUS GALVANIZED SUPPORT ANGLE OR CHANNEL AS REQUIRED TO BRIDGE STRUCTURE 2. SUSPEND DRAIN PAN WITH SUPPORT RODS WHEN ATTACHED TO BUILDING STRUCTURE. 3. ATTACH TO STRUCTURE WITH VIBRATION ISOLATION. FAN -COIL UNIT MOUNTING NO SCALE METAL BAND OVER INSULATION (TYPICAL) HIGH EFFICIENCY TAKEOFF, EXTERNALLY INSULATED COORDINATE BOX —OUT LOCATIONS FOR ALL DRYWALL MOUNTED AIR DEVICES WITH GENERAL CONTRACTOR AND CEILING FRAMING. CEILING DIFFUSER DETAIL NO SCALE 'Dg - D11 PIPE SADDLE (TYP.) 4 "x4 "x12" LONG MIN. TREATED WOOD BLOCK NOTE: PROVIDE SUPPORTS AT 3' -0" ON CENTERS AND WITHIN 1' -0" OF ALL CHANGES IN PIPE DIRECTION. REFRIGERANT PIPING SUPPORT ON ROOF NO SCALE REFER TO PLUMBING PLANS FOR PRIMARY AND SECONDARY DRAIN LINES. INSULATED DUCT VOLUME DAMPER AND LOCK WITH EXTENSION ANCHOR BOLT ROD BRACING (TYP 4 SIDES) SUSPENDED EQUIPMENT DETAIL A SUSPENDED EQUIPMENT WITH VIBRATION MOUNT DETAIL C NOTES: SEISMIC SUPPORT NO SCALE NOTES: TRANSVERSE BRACE CONNECT TO SUPPORTING , CONNECT TO SUPPORTING STRUCTURAL MEMBER SHEETMETAL DUCT VIBRATION ISOLATION 1/2" CLEARANCE MAXIMUM �� \ \ RANCE MAXIMUM VERTICAL HANGER LONGITUDINAL HANGER ONE EACH SIDE OF DUCT { HORIZONTAL BRACE CL BOLTS EQUAL Q OF ANGLES 1" TYPICAL 4 SIDES STRUCTURAL MEMBER INSULATION WHERE REQUIRED 1. CABLE BRACES MAY BE USED FOR SEISMIC RESTRAINT IN LIEU OF ANGLE BRACES. J 45' HIGH EFFICIENCY TAKE —OFF WITH SQUARE TO ROUND FITTING CENTER SEISMIC BRACING 4 FOR RECTANGULAR DUCTS NO SCALE 1. CUT OPENING IN SHEETMETAL DUCT ACCURATELY. INSTALL 45' LATERAL TO AVOID VISIBLE OPENINGS AND SECURE FITTING SUITABLY FOR PRESSURE CLASS. `.„ •� SUPPORT •\ FRAMING ALTERNATE • • LOCATION �• OF BRACE • (TYP 4 CORNERS) HANGER ROD NOTE: PROVIDE GREY OR ALUMINIZED DUCT TAPE SECURING EXTERNAL DUCT INSULATION 45 °LATERAL FLEXIBLE DUCT TAKE OFF DETAIL NO SCALE VIBRATION MOUNT WHERE APPLICABLE DIAGONAL BRACING (TYP. 4 SIDES) LOCK NUT BRACE FRAMING GAP ANGLE WITH RESILIENT PAD (TYP EACH CORNER) NOTES: 1.CABLE BRACES MAY BE USED RESTRAINT IN LIEU OF ANGLE DIAGONAL BRACING (TYP 4 SIDES) SUSPENDED EQUIPMENT DETAIL B FOR SEISMIC BRACES. DETAIL FOR HUNG EQUIPMENT FASTEN TO STRUCTURE 1" BAND CLAMP CONNECT TO AIR DEVICE NECK UNLESS OTHERWISE NOTED. SAME SIZE AS DIFFUSER NECK. RECEIVED FEB - 8 2008 PERMIT CENTER HENDERSON ENGINEERS= 10370 RICHMOND AVENUE, SUITE 370 HOUSTON, TX 77042 TEL 713 783 7707 FAX 713 783 7797 www.hei- eng.com 0750001294 RJS JMH SLM ISSUED/REVISED DATE HEALTH DEPT SUBMITTAL 12.17.07 98% OWNER REVIEW 01.03.08 HEALTH DEPT RVSNS 01.11.08 ISSUED FOR PERMIT 01.25.08 MCP. 11/97/08 J J M -2.0 N 0 0 U) MECHANICAL DETAILS CONDENSING UNIT SCHEDULE (SUPPLIED BY OWNER) MARK SERVICE MANUFACTURER MODEL REFR. TYPE TH (MBH) SH (MBH) MIN. NO. OF STAGES 1 SEER 13 MCA 13.8 MOCP 20 V /PH 480/3 DISC TYPE NF STARTER TYPE ATL WEIGHT LBS 124 NOTES A — H CU -1 FCU -1 CARRIER 24ABR324 R -22 19.9 15.0 NOTES: A. PROVIDE LOW AMBIENT CONTROL TO 0' F. B. EQUIPMENT SIZED FOR 90' F AMBIENT TEMPERATURE. C. COORDINATE WITH THE MANUFACTURER THE HORIZONTAL AND VERTICAL REFRIGERANT PIPE ROUTING TO DETERMINE PIPE SIZES FOR THE REFRIGERANT PIPING. MANUFACTURER SHALL PROVIDE DETAILED REFRIGERANT PIPING DIAGRAMS INCLUDING DIMENSIONAL DATA FOR ALL REFRIGERANT PIPING DEVICES. THE MANUFACTURER SHALL SIZE AND LOCATE THE ASSOCIATED REFRIGERANT TRAPS BASED ON THE ACTUAL ROUTING AND PROVIDE OTHER APPURTENANCES TO PROVIDE A FULLY FUNCTIONAL AND OPERATIONAL SYSTEM. COORDINATE WITH THE MANUFACTURER LOCATIONS FOR ALL REFRIGERANT PIPING DEVICES TO MAINTAIN SERVICEABILITY AND ACCESSIBILITY. D. PROVIDE MANUFACTURER'S LONG —LINE ACCESSORY KIT. E. PROVIDE LIQUID LINE FILTER DRYER AND SIGHT GLASS. F. DISCONNECT SWITCH FURNISHED BY DIVISION 16 CONTRACTOR. G. STARTERS FOR ALL MOTORS SHALL BE FURNISHED INTEGRAL WITH UNIT. H. COORDINATE SIZE OF CONDUCTOR TERMINATION LUGS WITH CONDUCTOR SIZES SHOWN ON ELECTRICAL DRAWINGS. FAN COIL UNIT SCHEDULE (SUPPLIED BY OWNER) MARK MANUFACTURER MODEL SUPPLY FAN COOLING COIL ELECTRICAL WEIGHT LBS NOTES CFM MIN. HP ESP (IN) TSP (IN) REFR. TYPE TH (MBH) SH (MBH) EAT (DB /WB) LAT (DB) V /PH MCA MOCP DISC. TYPE STARTER TYPE FCU -1 CARRIER FA4CNF024 835 1/4 0.3 0.55 R -22 19.9 15.0 73.7/62.1 57 208/1 2.3 15 NF MAGNETIC 112 A — L NOTES: A. EQUIPMENT COMPONENTS SHALL BE BY THE SAME MANUFACTURER. B. EQUIPMENT SIZED FOR 90' F AMBIENT TEMPERATURE. C. PROVIDE 1" PANEL THROWAWAY AIR FILTERS. D. PROVIDE WITH BACK INLET CONNECTION. E. PROVIDE WITH FRONT OUTLET CONNECTION. F. PROVIDE WITH 7—DAY PROGRAMMABLE THERMOSTAT FOR OPERATION OF COOLING CONTROLS. G. DIVISION 16 CONTRACTOR TO FURNISH AND DIVISION 15 CONTRACTOR TO INSTALL A SMOKE DETECTOR IN THE SUPPLY AIR DUCT. H. DISCONNECT SWITCH FURNISHED BY DIVISION 16 CONTRACTOR. I. STARTERS FOR ALL MOTORS SHALL BE FURNISHED INTEGRAL WITH UNIT. J. PROVIDE WITH SPRING VIBRATION ISOLATION AND ALL — THREAD HANGING RODS. K. SPECIFIED FAN ESP ACCOUNTS FOR DUCT LOSSES EXTERNAL TO UNIT. L. SPECIFIED FAN TSP INCLUDES EXTERNAL DUCT AND INTERNAL FILTER, COIL AND CASING LOSSES. FILTER LOSS IS AT MAXIMUM 400 FPM. FAN—POWERED VARIABLE AIR VOLUME TERMINAL SCHEDULE — ELECTRIC HEAT (SUPPLIED BY OWNER) MARK UNIT SERVED MANUFACTURER MODEL UNIT SIZE INLET SIZE (IN) PRIMARY FAN CFM HEATING COIL FAN NOISE CRITERIA (NC) NOTES MAX CFM MIN CFM EAT MBH KW STEPS V /PH HP V /PH RADIATED DISCHARGE VAV-1 LAC-1A TITUS DTQS 3 12 1 175 350 1 175 -- -- -- -- -- 1/4 120/1 33 23 A — I NOTES: A. PROVIDE FILTER FRAME WITH 1 " THROWAWAY FILTERS. B. INSTALL WITH FLEXIBLE DUCT CONNECTORS AT ALL CONNECTIONS. C. FAN CFM BASED ON 0.35" MINIMUM STATIC PRESSURE LEAVING BOX. D. PROVIDE INTEGRAL DISCONNECT SWITCH. E. PROVIDE FACTORY INSTALLED CONTROL POWER TRANSFORMER. F. BOX NOT TO EXCEED SCHEDULED DISCHARGE OR RADIATED NC USING 0.5" W.G. INLET PRESSURE. G. PROVIDE FACTORY— INSTALLED, PRESSURE INDEPENDENT, DDC CONTROL PACKAGE INTEROPERABLE WITH SHELL BUILDING CONTROL SYSTEM. H. HEATING COIL CAPACITY BASED ON 35'F MAX. AIR TEMPERATURE RISE, 90'F MAX. DISCHARGE AIR TEMPERATURE, AND 450 FPM MINIMUM COIL FACE VELOCITY. I. MOUNT HEATING COIL ON SUPPLY AIR DISCHARGE CONNECTION. GRILLE, REGISTER AND DIFFUSER SCHEDULE MARK MANUFACTURER MODEL FACE TYPE MOUNTING LOCATION FACE SIZE (IN) 24x24 MAX. NC 30 MAX. PRESS. DROP (IN. W.C.) 0.1 NOTES A, B, C, D, E, F, G CSD TITUS TDV SQUARE CEILING CRG TITUS 50F EGGCRATE CEILING SEE PLAN 30 0.1 C, D, F NOTES: A. PROVIDE NECK FOR DUCT CONNECTION. NECK SIZE SHOWN ON DRAWINGS. B. 4 —WAY THROW PATTERN UNLESS OTHERWISE SHOWN ON DRAWINGS. C. BRANCH DUCT SIZE SHALL BE SAME AS NECK SIZE UNLESS OTHERWISE SHOWN ON DRAWINGS. D. BAKED ENAMEL FINISH, OFF—WHITE TO MATCH CEILING COLOR. E. PROVIDE VOLUME DAMPER IN DIFFUSER NECK. F. FRAME TYPE TO MATCH CEILING CONSTRUCTION, COORDINATE WITH ARCHITECTURAL REFLECTED CEILING PLAN. G. SUPPLIED BY OWNER. PROJECT DESIGN CONDITIONS SPACE SERVED SUMMER DESIGN DRY BULB TEMP (F) SUMMER DESIGN WB TEMP (F) /RH ( %) WINTER DESIGN TEMPERATURE (F) WINTER DESIGN RH% NOTES OUTSIDE AIR 85 F 65 F 23 F NA A,B SALES 70 F 58 F / 50% RH 65 F 30% 635 STORAGE 60 F NA 60 F NA NOTES: A. OUTSIDE AIR SUMMER TEMPERATURES BASED ON ASHRAE 0.4% DESIGN CONDITIONS. B. OUTSIDE AIR WINTER TEMPERATURES BASED ON ASHRAE 99.6% DESIGN CONDITIONS. OUTSIDE AIR REQUIREMENTS AREA PURPOSE GROSS FLOOR AREA (SQ. FT) CODE OUTSIDE AIR REQUIREMENTS SYSTEM NUMBER ACTUAL OUTSIDE AIR (CFM PER UNIT) CFM PER SQ. FT CFM REQD. CFM PER PERSON NO. OF PEOPLE CFM REQD. LAC -1 A* 10,560 SA (1,937 OA) SALES 635 0.30 191 0 STORAGE 160 0.15 24 0 TOTAL — 215 0 * LAC -1A IS INSTALLED UNDER THE SHELL BUILDING AND HAS 18.34% OUTDOOR AIR CAPACITY WITH AN ECONOMIZER CYCLE. TOTAL — 215 1 2 3 4 5 6 7 8 9 5.011 10 HENDERSON ENGINEERS= 10370 RICHMOND AVENUE, SUITE 370 HOUSTON, TX 77042 Try. 713 783 7707 FAX 713 783 7797 www.he7- eng.cem 0750001294 RJS 1MH SI.M so rtt FEB - 8 2008 PERMIT CENTEF, 0 M -3.0 EXE fl/ teab i+i t Zt U N 0 c95 0 ISSUED / REVISED DATE HEALTH DEPT SUBMITTAL 12.17.07 98% OWNER REVIEW 01.03.08 HEALTH DEPT RVSNS 01.11.08 ISSUED FOR PERMIT 01.25.08 MECHANICAL SCHEDULES 1 2 3 4 6 7 8 9 10 15A: Heating, Ventilating, and Air Conditioning: 15A 1 GENERAL INSTRUCTIONS 15A 1 -1 GENERAL REQUIREMENTS REQUIREMENTS UNDER DIVISION ONE AND THE GENERAL AND SUPPLEMENTARY CONDITIONS OF THESE SPECIFICATIONS SHALL BE A PART OF THIS SECTION. CONTRACTOR SHALL BECOME THOROUGHLY ACQUAINTED WITH ITS CONTENTS AS TO REQUIREMENTS THAT AFFECT THIS DIVISION OR SECTION. THE WORK REQUIRED UNDER THIS SECTION INCLUDES MATERIAL, EQUIPMENT, APPLIANCES, TRANSPORTATION, SERVICES, AND LABOR REQUIRED TO COMPLETE THE ENTIRE SYSTEM AS REQUIRED BY THE DRAWINGS AND SPECIFICATIONS. THE SPECIFICATIONS AND DRAWINGS FOR THE PROJECT ARE COMPLEMENTARY, AND PORTIONS OF THE WORK DESCRIBED IN ONE, SHALL BE PROVIDED AS IF DESCRIBED IN BOTH. IN THE EVENT OF DISCREPANCIES, NOTIFY THE ENGINEER AND REQUEST CLARIFICATION PRIOR TO PROCEEDING WITH THE WORK INVOLVED. 15A 1 -2 DEFINITIONS FURNISH: THE TERM "FURNISH" IS USED TO MEAN "SUPPLY AND DELIVER TO THE PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION AND SIMILAR OPERATIONS." INSTALL: THE TERM "INSTALL" IS USED TO DESCRIBE OPERATIONS AT THE PROJECT SITE INCLUDING THE ACTUAL "UNLOADING, UNPACKING, ASSEMBLY, ERECTION, PLACING, ANCHORING, APPLYING, WORKING TO DIMENSION, FINISHING, CURING, PROTECTING, CLEANING, AND SIMILAR OPERATIONS." PROVIDE: THE TERM "PROVIDE" MEANS "TO FURNISH AND INSTALL, COMPLETE AND READY FOR THE INTENDED USE." FURNISHED BY OWNER OR FURNISHED BY OTHERS: THE ITEM WILL BE FURNISHED BY THE OWNER OR OTHERS. IT IS TO BE INSTALLED AND CONNECTED UNDER THE REQUIREMENTS OF THIS DIVISION, COMPLETE AND READY FOR OPERATION, INCLUDING ITEMS INCIDENTAL TO THE WORK, INCLUDING SERVICES NECESSARY FOR PROPER INSTALLATION AND OPERATION. THE INSTALLATION SHALL BE INCLUDED UNDER THE GUARANTEE REQUIRED BY THIS DIVISION. ENGINEER: WHERE REFERENCED IN THIS DIVISION, "ENGINEER" IS THE ENGINEER OF RECORD AND THE DESIGN PROFESSIONAL FOR THE WORK UNDER THIS DIVISION, AND IS A CONSULTANT TO, AND AN AUTHORIZED REPRESENTATIVE OF, THE ARCHITECT, AS DEFINED IN THE GENERAL AND /OR SUPPLEMENTARY CONDITIONS. WHEN USED IN THIS DIVISION, TT MEANS INCREASED INVOLVEMENT BY, AND OBLIGATIONS TO, THE ENGINEER, IN ADDITION TO INVOLVEMENT BY, AND OBLIGATIONS TO, THE "ARCHITECT ". AHJ: THE LOCAL CODE AND/OR N AGENCY INSPECTION AUTHORITY HAVING E JURISDICTION OVER THE WORK. THE TERMS "APPROVED EQUAL ", "EQUIVALENT ", OR "EQUAL" ARE USED SYNONYMOUSLY AND SHALL MEAN "ACCEPTED BY OR ACCEPTABLE TO THE ENGINEER AS EQUIVALENT TO THE ITEM OR MANUFACTURER SPECIFIED ". THE TERM "APPROVED" SHALL MEAN LABELED, LISTED, OR BOTH, BY A NATIONALLY RECOGNIZED TESTING LABORATORY (E.G. UL, ETL, CSA), AND ACCEPTABLE TO THE AHJ OVER THIS PROJECT. 15A 1 -3 PREBID SITE VISIT PRIOR SUBMITTING BID, VISIT THE SITE OF THE PROPOSED WORK TO SUBMITT SED ORK AND BECOME FULLY INFORMED AS TO THE CONDITIONS UNDER WHICH THE WORK IS TO BE DONE. FAILURE TO DO SO WILL NOT BE CONSIDERED SUFFICIENT JUSTIFICATION TO REQUEST OR OBTAIN EXTRA COMPENSATION OVER AND ABOVE THE CONTRACT PRICE. 15A 1 -4 MATERIAL AND WORKMANSHIP PROVIDE NEW MATERIAL, EQUIPMENT, AND APPARATUS UNDER THIS CONTRACT UNLESS OTHERWISE STATED HEREIN, OF BEST QUALITY NORMALLY USED FOR THE PURPOSE IN GOOD COMMERCIAL PRACTICE, AND FREE FROM DEFECTS. MODEL NUMBERS LISTED IN THE SPECIFICATIONS OR SHOWN ON THE DRAWINGS ARE NOT NECESSARILY INTENDED TO DESIGNATE THE REQUIRED TRIM, WRITTEN DESCRIPTIONS OF THE TRIM GOVERN MODEL NUMBERS. WORK PERFORMED UNDER THIS CONTRACT SHALL PROVIDE A NEAT AND "WORKMANLIKE" APPEARANCE WHEN COMPLETED, TO THE SATISFACTION OF THE ARCHITECT AND ENGINEER. WORKMANSHIP SHALL BE THE FINEST POSSIBLE BY EXPERIENCED MECHANICS. INSTALLATIONS SHALL COMPLY WITH APPLICABLE CODES AND LAWS. THE COMPLETE INSTALLATION SHALL FUNCTION AS DESIGNED AND INTENDED WITH RESPECT TO EFFICIENCY, CAPACITY, NOISE LEVEL, ETC. ABNORMAL NOISE CAUSED BY RATTLING EQUIPMENT, PIPING, DUCTS, AIR DEVICES, AND SQUEAKS IN ROTATING COMPONENTS WILL NOT BE ACCEPTABLE. IN GENERAL, MATERIALS AND EQUIPMENT SHALL BE OF COMMERCIAL SPECIFICATION GRADE qE IN QUALITY. LIGHT DUTY AND RESIDENTIAL TYPE EQUIPMENT WILL NOT BE ACCEPTED. REMOVE FROM THE PREMISES WASTE MATERIAL PRESENT AS A RESULT OF WORK, INCLUDING CARTONS, CRATING, PAPER, STICKERS, AND /OR EXCAVATION MATERIAL NOT USED IN BACKFILLING, ETC. CLEAN EQUIPMENT INSTALLED UNDER THIS CONTRACT TO PRESENT A NEAT AND CLEAN INSTALLATION AT THE TERMINATION OF THE WORK. REPAIR OR REPLACE PUBLIC AND PRIVATE PROPERTY DAMAGED AS A RESULT OF WORK PERFORMED UNDER THIS CONTRACT TO THE SATISFACTION OF AUTHORITIES AND REGULATIONS HAVING JURISDICTION. 15A 1 -5 COORDINATION COORDINATE WORK WITH THAT OF OTHER TRADES SO THAT THE VARIOUS COMPONENTS OF THE SYSTEMS WILL BE INSTALLED AT THE PROPER TIME, WILL FIT THE AVAILABLE SPACE, AND WILL ALLOW PROPER SERVICE ACCESS TO THOSE ITEMS REQUIRING MAINTENANCE. COMPONENTS WHICH ARE INSTALLED WITHOUT REGARD TO THE ABOVE SHALL BE RELOCATED AT NO ADDITIONAL COST TO THE OWNER. UNLESS OTHERWISE INDICATED, THE GENERAL CONTRACTOR WILL PROVIDE CHASES AND OPENINGS IN BUILDING CONSTRUCTION REQUIRED FOR INSTALLATION OF THE SYSTEMS SPECIFIED HEREIN. CONTRACTOR SHALL FURNISH THE GENERAL CONTRACTOR WITH INFORMATION WHERE CHASES AND OPENINGS ARE REQUIRED. KEEP INFORMED AS TO THE WORK OF OTHER TRADES ENGAGED IN THE CONSTRUCTION OF THE PROJECT, AND EXECUTE WORK IN A MANNER AS TO NOT INTERFERE WITH OR DELAY THE WORK OF OTHER TRADES. FIGURED DIMENSIONS SHALL BE TAKEN IN PREFERENCE TO SCALE DIMENSIONS. CONTRACTOR SHALL TAKE HIS OWN MEASUREMENTS AT THE BUILDING, AS VARIATIONS MAY OCCUR. CONTRACTOR WILL BE HELD RESPONSIBLE FOR ERRORS THAT COULD HAVE BEEN AVOIDED BY PROPER CHECKING AND INSPECTION. PROVIDE MATERIALS WITH TRIM THAT WILL PROPERLY FIT THE TYPES OF CEILING, WALL, OR FLOOR FINISHES ACTUALLY INSTALLED MODEL NUMBERS LISTED IN THE SPECIFICATIONS OR SHOWN ON THE DRAWINGS ARE NOT INTENDED TO DESIGNATE THE REQUIRED TRIM. 15A 1 -6 ORDINANCES AND CODES WORK PERFORMED UNDER THIS CONTRACT SHALL, AT A MINIMUM, BE IN CONFORMANCE WITH APPLICABLE NATIONAL, STATE AND LOCAL CODES HAVING JURISDICTION. EQUIPMENT FURNISHED AND ASSOCIATED INSTALLATION WORK PERFORMED UNDER THIS CONTRACT SHALL BE IN STRICT COMPLIANCE WITH CURRENT APPLICABLE CODES ADOPTED BY THE LOCAL AHJ INCLUDING ANY AMENDMENTS AND STANDARDS AS SET FORTH BY THE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), UNDERWRITERS LABORATORIES (UL), OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA), AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME), AMERICAN SOCIETY OF HEATING, REFRIGERATION, AND AIR CONDITIONING ENGINEERS (ASHRAE), AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI), AMERICAN SOCIETY OF TESTING MATERIALS (ASTM) AND OTHER NATIONAL STANDARDS AND CODES WHERE APPLICABLE. WHERE THE CONTRACT DOCUMENTS EXCEED THE REQUIREMENTS OF THE REFERENCED CODES, STANDARDS, ETC., THE CONTRACT DOCUMENTS SHALL TAKE PRECEDENCE. PROCURE AND PAY FOR PERMITS AND LICENSES REQUIRED FOR THE ACCOMPLISHMENT OF THE WORK HEREIN DESCRIBED. WHERE REQUIRED, OBTAIN, PAY FOR AND FURNISH CERTIFICATES OF INSPECTION TO OWNER. CONTRACTOR WILL BE HELD RESPONSIBLE FOR VIOLATIONS OF THE LAW. 15A 1 -7 PROTECTION OF EQUIPMENT AND MATERIALS STORE AND PROTECT FROM DAMAGE EQUIPMENT AND MATERIALS DELIVERED TO JOB SITE. COVER WITH WATERPROOF, TEAR— RESISTANT, HEAVY TARP OR POLYETHYLENE PLASTIC AS REQUIRED TO PROTECT FROM PLASTER, DIRT, PAINT, WATER, OR PHYSICAL DAMAGE. EQUIPMENT AND MATERIAL THAT HAS BEEN DAMAGED BY CONSTRUCTION ACTIVITIES WILL BE REJECTED, AND CONTRACTOR IS OBLIGATED TO FURNISH NEW EQUIPMENT AND MATERIAL OF A LIKE KIND. KEEP PREMISES BROOM CLEAN FROM FOREIGN MATERIAL CREATED DURING WORK PERFORMED UNDER THIS CONTRACT. PIPING, EQUIPMENT, ETC. SHALL HAVE A NEAT AND CLEAN APPEARANCE AT THE TERMINATION OF THE WORK. PLUG OR CAP OPEN ENDS OF DUCTWORK AND PIPING SYSTEMS WHILE STORED AND INSTALLED DURING CONSTRUCTION WHEN NOT IN USE TO PREVENT THE ENTRANCE OF DEBRIS INTO THE SYSTEMS. 15A 1 -8 ELECTRONIC DRAWING FILES IN PREPARATION OF SHOP DRAWINGS, CONTRACTOR MAY, AT HIS OPTION, OBTAIN ELECTRONIC DRAWING FILES IN AUTOCAD OR DXF FORMAT ON CD —ROM DISK FROM THE ENGINEER FOR A SHIPPING AND HANDLING FEE OF $200 FOR A DRAWING SET UP TO 12 SHEETS AND $15 PER SHEET FOR EACH ADDITIONAL SHEET. CONTRACTOR SHALL CONTACT THE ARCHITECT FOR WRITTEN AUTHORIZATION AND ENGINEER FOR THE NECESSARY RELEASE AGREEMENT FORM AND TO SPECIFY SHIPPING METHOD AND DRAWING FORMAT. IN ADDITION TO PAYMENT, ARCHITECT'S WRITTEN AUTHORIZATION AND ENGINEER'S RELEASE AGREEMENT FORM MUST BE RECEIVED BEFORE ELECTRONIC DRAWING FILES WILL BE SENT. 15A 1 -9 WARRANTIES WARRANT EACH SYSTEM AND EACH ELEMENT THEREOF AGAINST ALL DEFECTS DUE TO FAULTY WORKMANSHIP, DESIGN OR MATERIAL FOR A PERIOD OF 12 MONTHS FROM DATE OF SUBSTANTIAL COMPLETION, UNLESS SPECIFIC ITEMS ARE NOTED TO CARRY A LONGER WARRANTY IN THE CONSTRUCTION DOCUMENTS OR MANUFACTURER'S STANDARD WARRANTY EXCEEDS 12 MONTHS. REMEDY ALL DEFECTS, OCCURRING WITHIN THE WARRANTY PERIOD(S), AS STATED IN THE GENERAL CONDITIONS AND DIVISION 1. WARRANTIES SHALL INCLUDE LABOR AND MATERIAL. MAKE REPAIRS OR REPLACEMENTS WITHOUT ANY ADDITIONAL COSTS TO THE OWNER. PERFORM THE REMEDIAL WORK PROMPTLY, UPON WRITTEN NOTICE FROM THE ENGINEER OR OWNER. AT THE TIME OF SUBSTANTIAL COMPLETION, DELIVER TO THE OWNER ALL WARRANTIES, IN WRITING AND PROPERLY EXECUTED, INCLUDING TERM LIMITS FOR WARRANTIES EXTENDING BEYOND THE ONE YEAR PERIOD, EACH WARRANTY INSTRUMENT BEING ADDRESSED TO THE OWNER AND STATING THE COMMENCEMENT DATE AND TERM. 15A 1 -10 CUTTING AND PATCHING PERFORM CUTTING OF WALLS, CEILINGS, ETC. AS REQUIRED TO INSTALL WORK UNDER THIS SECTION. OBTAIN PERMISSION FROM THE ARCHITECT PRIOR TO CU I I ING. DO NOT CUT OR DISTURB STRUCTURAL MEMBERS WITHOUT PRIOR APPROVAL FROM THE ARCHITECT. CUT HOLES AS SMALL AS POSSIBLE. E AR E GENERAL CONTRACTOR SHALL PATCH WALLS, ETC. AS REQUIRED BY WORK UNDER THIS SECTION. PATCHING SHALL MATCH THE ORIGINAL MATERIAL AND CONSTRUCTION. REPAIR AND REFINISH AREAS DISTURBED BY WORK TO THE CONDITION OF ADJOINING SURFACES IN A MANNER SATISFACTORY TO THE ARCHITECT. 15A 1 -11 ROUGH —IN COORDINATE WITHOUT DELAY ROUGHING —IN WITH GENERAL CONSTRUCTION. CONCEAL PIPING AND CONDUIT ROUGH —IN EXCEPT IN UNFINISHED AREAS AND WHERE OTHERWISE SHOWN. 15A 1 -12 STRUCTURAL STEEL STRUCTURAL STEEL USED FOR SUPPORT OF EQUIPMENT, DUCTWORK AND PIPING SHALL BE NEW, CLEAN, AND CONFORM TO ASTM DESIGNATION A -36. SUPPORT MECHANICAL COMPONENTS FROM THE BUILDING STRUCTURE. DO NOT SUPPORT MECHANICAL COMPONENTS FROM CEILINGS, OTHER MECHANICAL OR ELECTRICAL COMPONENTS, AND OTHER NON— STRUCTURAL ELEMENTS. 15A 1-13 ACCESS DOORS PROVIDE ACCESS DOORS IN CEIUNGS, WALLS, ETC. WHERE INDICATED OR REQUIRED FOR ACCESS OR MAINTENANCE TO CONCEALED VALVES AND EQUIPMENT INSTALLED UNDER THIS SECTION. 15A 1-14 PENETRATIONS SEAL MECHANICAL FLOOR, EXTERIOR WALL AND ROOF PENETRATIONS WATERTIGHT AND WEATHERTIGHT. SEAL AROUND MECHANICAL PENETRATIONS WITH 3M CP -25 FIRE BARRIER CAULK (THICKNESS AS REQUIRED AND RECOMMENDED BY MANUFACTURER) TO MAINTAIN FIRE RESISTANCE RATING OF FIRE —RATED ASSEMBLIES. PROVIDE PREFABRICATED ROOF CURBS MANUFACTURED BY CUSTOM CURB, INC., PATE COMPANY, THYCURB OR APPROVED EQUAL. PROVIDE ROOF CURB WITH FACTORY INSTALLED WOOD NAILER; WELDED, 18 GAUGE GALVANIZED STEEL SHELL, BASE PLATE AND FLASHING; 1 -1/2" THICK, 3 POUND RIGID INSULATION; FULLY MITERED 3 —INCH RAISED CANT; COVER OF WEATHER — RESISTANT, WEATHER— PROOF MATERIAL AND PIPE COLLAR OF WEATHER—RESISTANT MATERIAL WITH STAINLESS STEEL PIPE CLAMPS. 15A 1 -15 AIR FILTERS PROVIDE FARR 30/30 PLEATED, THROWAWAY TYPE FILTERS, UNLESS OTHERWISE INDICATED. AIR UNITS SHALL HAVE NEW FILTERS INSTALLED WHEN THEY ARE OPERATED BEFORE FINAL ACCEPTANCE. FILTERS SHALL BE MANUFACTURED BY AMERICAN AIR FILTER, FARR, FLANDERS, OR APPROVED EQUAL. IF HVAC EQUIPMENT IS USED DURING THE CONSTRUCTION PERIOD, CONTRACTOR SHALL PROVIDE ONE SET OF FILTERS WHEN THE UNIT IS STARTED AND REPLACE FILTERS WHEN NEEDED, BUT NOT LESS THAN EVERY MONTH. ON THE DAY OF SUBSTANTIAL COMPLETION, THE CONTRACTOR SHALL CLEAN THE UNIT AND PROVIDE A NEW SET OF FILTERS IN THE UNIT. 15A 1 -16 MOTORS AND STARTERS PROVIDE MOTORS AND STARTING EQUIPMENT WHERE NOT FURNISHED WITH THE EQUIPMENT PACKAGE. MOTORS SHALL HAVE COPPER WINDINGS, CLASS B INSULATION, AND STANDARD SQUIRREL CAGE WITH STARTING TORQUE CHARACTERISTICS SUITABLE FOR THE EQUIPMENT SERVED. MOTORS FOR AIR HANDLING EQUIPMENT SHALL BE SELECTED FOR QUIET OPERATION. EACH MOTOR SHALL BE CHECKED FOR PROPER ROTATION AFTER ELECTRICAL CONNECTION HAS BEEN COMPLETED. PROVIDE DRIPPROOF ENCLOSURE FOR LOCATIONS PROTECTED FROM WEATHER AND NOT IN AIR STREAM OF FAN; AND TOTALLY ENCLOSED FAN COOLED ENCLOSURE FOR MOTORS EXPOSED TO WEATHER. MOTORS SHALL BE MANUFACTURED BY CENTURY, GENERAL ELECTRIC, WESTINGHOUSE, LOUIS ALUS, OR APPROVED EQUAL. PROVIDE EVERY MOTOR, EXCEPT FRACTIONAL HORSEPOWER SINGLE PHASE MOTORS WITH AN APPROVED TYPE OF "BUILT —IN" THERMAL OVERLOAD PROTECTION, WITH A MOTOR STARTER. EACH STARTER SHALL BE PROVIDED WITH OVERLOAD HEATERS SIZED TO THE MOTOR RATING, AND EVERY THREE PHASE MOTOR STARTER SHALL HAVE OVERLOAD HEATERS IN EACH PHASE. AMBIENT COMPENSATED HEATERS SHALL BE INSTALLED WHEREVER NECESSARY. UNLESS NOTED OTHERWISE, MOTOR STARTERS SHALL BE FURNISHED BY THE DIVISION 15 CONTRACTOR FOR INSTALLATION AND CONNECTION BY THE DIVISION 16 CONTRACTOR. STARTERS SHALL BE ALLEN — BRADLEY, CLARK, FURNAS, SQUARE D, OR APPROVED EQUAL. 15A 1 -17 ELECTRICAL WIRING UNE VOLTAGE WIRING SHALL BE PROVIDED BY DIVISION 16. LINE VOLTAGE CONTROL AND INTERLOCK WIRING FOR MECHANICAL SYSTEMS SHALL ALSO BE PROVIDED BY DIVISION 16 CONTRACTOR. LOW VOLTAGE CONTROL WIRING SHALL BE PROVIDED BY THE DIVISION 15 CONTRACTOR. FURNISH WIRING DIAGRAMS TO THE DIVISION 16 CONTRACTOR AS REQUIRED FOR PROPER EQUIPMENT HOOKUP. COORDINATE WITH THE DIVISION 16 CONTRACTOR THE ACTUAL WIRE SIZING AMPS FOR MECHANICAL EQUIPMENT (FROM THE EQUIPMENT NAMEPLATE) TO ENSURE PROPER INSTALLATION. 15A 1 -18 REFRIGERANT AND OIL PROVIDE FULL REFRIGERANT AND OIL CHARGE IN NEW AIR CONDITIONING REFRIGERATION SYSTEMS, AND MAINTAIN IT FOR FULL TERM OF THE GUARANTEE. 15A 1 -19 FINAL TESTING AND ADJUSTMENTS FINAL SYSTEM TESTING, BALANCING AND ADJUSTMENTS SHALL BE PERFORMED BY A CONTRACTOR CERTIFIED BY THE NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB), ASSOCIATED AIR BALANCE COUNCIL (AABC) OR OTHER APPROVED AGENCY OR AS REQUIRED BY LANDLORD. 15A 1 -20 BUILDING OPERATION COMPLY WITH THE SCHEDULE OF OPERATIONS AS OUTLINED IN THE ARCHITECTURAL PORTIONS OF THIS SPECIFICATION. BUILDING SHALL BE IN CONTINUOUS OPERATION. ACCOMPLISH WORK REQUIRING INTERRUPTION OF BUILDING OPERATION AT A TIME WHEN THE BUILDING IS NOT IN OPERATION, AND ONLY WITH WRITTEN APPROVAL OF BUILDING OWNER AND /OR TENANT. COORDINATE INTERRUPTION OF BUILDING OPERATION WITH THE OWNER AND /OR TENANT A MINIMUM OF SEVEN DAYS IN ADVANCE OF WORK. 5A 1 -21 SEISMIC REQUIREMENTS UIREMENTS Q SEISMIC PROTECTION FOR SEISMIC CONCERNS OF ALL MECHANICAL AND ELECTRIC SYSTEMS EXCEPT FIRE PROTECTION SYSTEMS MUST MEET MINIMUM REQUIREMENTS OF 2003 IBC FOR BUILDINGS CLASSIFIED AS SEISMIC USE GROUP II AND SEISMIC DESIGN CATEGORY D. SEISMIC PROTECTION OF WATER PIPES FOR FIRE PROTECTION SYSTEMS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE PROVISIONS OF NFPA 13. SEISMIC RESTRAINTS, ISOLATORS, AND ISOLATION MATERIALS SHALL BE OF THE SAME MANUFACTURER, SHALL BE CERTIFIED BY THE MANUFACTURER AND SHALL BE BY AMBER /BOOTH COMPANY, INC., KINETICS NOISE CONTROL, INC., LOOS & COMPANY, INC., MASON INDUSTRIES, INC. OR UNI— STRUT. RESTRAINING DEVICES SHALL HAVE A PRE — APPROVAL NUMBER FROM CALIFORNIA OSHPD OR OTHER RECOGNIZED GOVERNMENT AGENCY SHOWING MAXIMUM RESTRAINT RATINGS. THE REQUIREMENTS FOR SEISMIC PROTECTION MEASURES TO BE APPLIED TO MECHANICAL /ELECTRICAL EQUIPMENT AND SYSTEMS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE, AND /OR FEDERAL CODES AND WITH MANUFACTURER'S REQUIREMENTS, THE MOST STRINGENT SHALL APPLY. ALL ANCHOR CONNECTIONS TO STRUCTURE FOR SUPPORT OF MECHANICAL AND ELECTRICAL EQUIPMENT, REGARDLESS OF THE NEED FOR SEISMIC RESTRAINTS, SHALL BE SHOWN ON SHOP DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE TYPE AND LOCATION OF SEISMIC RESTRAINTS REQUIRED FOR THE MECHANICAL AND ELECTRICAL ELEMENTS SHOWN ON THE CONTRACT DRAWINGS BASED ON THE SEISMIC CODE CRITERIA STATED ABOVE, THE SIZE AND WEIGHT OF THE SUPPORTED ELEMENT AND THE DISTANCE FROM STRUCTURE THAT THE ELEMENT WILL BE INSTALLED. THE CONTRACTOR SHALL SUBMIT DESCRIPTIVE CATALOG DATA OF SEISMIC RESTRAINTS, SHOP DRAWINGS SHOWING THE TYPES, LOCATIONS AND INSTALLATION DETAILS OF SEISMIC RESTRAINTS AND CALCULATIONS SHOWING THAT THE SEISMIC RESTRAINTS MEET THE SEISMIC REQUIREMENTS TO THE ENGINEER OF RECORD AND TO THE LOCAL AUTHORITY HAVING JURISDICTION FOR REVIEW AND APPROVAL. CALCULATIONS SHALL BE SIGNED AND SEALED BY A REGISTERED PROFESSIONAL ENGINEER, LICENSED IN THE STATE OF THE PROJECT LOCATION AND EMPLOYED BY THE MANUFACTURER OF THE SEISMIC RESTRAINT PRODUCTS. CALCULATIONS SHALL INCLUDE DEAD LOADS, STATIC SEISMIC LOADS AND CAPACITY OF MATERIALS UTILIZED FOR CONNECTIONS TO EQUIPMENT AND STRUCTURE. 15A 2 INSULATION AND SHEET METAL WORK 15A 2 -1 DUCT INSULATION PROVIDE DUCT UNER IN RECTANGULAR SUPPLY AND RETURN AIR DUCTWORK. LINER SHALL BE 1 -1/2" THICK, 3 POUND DENSITY FIBERGLASS, CERTAINTEED CORP. "TOUGHGARD" OR OWENS— CORNING "AEROFLEX DUCT LINER. LINER SURFACE SHALL SERVE AS A BARRIER AGAINST INFILTRATION OF DUST AND DIRT, SHALL MEET ASTM C 1338 FOR FUNGI RESISTANCE AND SHALL BE CLEANABLE USING DUCT CLEANING METHODS AND EQUIPMENT OUTLINED BY NORTH AMERICAN INSULATION MANUFACTURERS ASSOCIATION (NAIMA) DUCT CLEANING GUIDE. INSTALL WITH UNER ADHESIVE AND MECHANICAL FASTENERS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. DUCTWORK SIZES SHOWN ON DRAWINGS ARE INSIDE CLEAR DIMENSIONS. INCREASE SHEET METAL BY LINER THICKNESS IN BOTH DIRECTIONS WHERE LINER IS INSTALLED. COVER CONCEALED RIGID ROUND SUPPLY, RETURN, AND OUTSIDE AIR DUCTWORK AND RECTANGULAR OUTSIDE AIR DUCTWORK WITH 2" THICK DUCT WRAP, CERTAINTEED OR EQUAL OWENS — CORNING, 3/4 POUND DENSITY, WITH HEAVY — DUTY FOIL —SCRIM —KRAFT FACING, AND WITH JOINTS TAPED WITH 3" WIDE FOIL TAPE. INSULATING MATERIALS, ADHESIVES, COATINGS, ETC., SHALL NOT EXCEED FLAME SPREAD RATING OF 25 AND SMOKE DEVELOPED RATING OF 50 PER ASTM E 84. CONTAINERS FOR MASTICS AND ADHESIVES SHALL HAVE U.L. LABEL. 15A 2 -2 DUCTWORK PROVIDE GALVANIZED STEEL DUCTWORK AND HOUSINGS AS SHOWN ON DRAWINGS. CONSTRUCT DUCTWORK INCLUDING FITTINGS AND TRANSITIONS IN CONFORMANCE WITH CURRENT SMACNA STANDARDS RELATIVE TO GAUGE, BRACING, JOINTS, ETC. MINIMUM THICKNESS OF DUCT SHALL BE 26 GAUGE SHEET METAL. REINFORCE HOUSINGS AND DUCTWORK OVER 30" WITH 1 -1/4" ANGLES NOT LESS THAN 5' -6" ON CENTERS, AND CLOSER IF REQUIRED FOR SUFFICIENT RIGIDITY TO PREVENT VIBRATION. SUPPORT HORIZONTAL RUNS OF DUCT FROM STRAP IRON HANGERS ON CENTERS NOT TO EXCEED 8' -0 ". DO NOT SUPPORT CEILING GRID, CONDUITS, PIPES, EQUIPMENT, ETC. FROM DUCTWORK. COORDINATE ROUTING OF DUCTWORK WITH OTHER CONTRACTORS SUCH THAT PIPING, ELECTRICAL CONDUIT AND ASSOCIATED SUPPORTS ARE NOT ROUTED THROUGH THE DUCTWORK. PROVIDE AIRFOIL TYPE TURNING VANES, OF SAME GAUGE AS DUCTWORK, RIGIDLY FASTENED WITH GUIDE STRIPS IN DUCTWORK HAVING AN OFFSET OF 45 DEGREES OR MORE. DUCTS SHALL BE CONNECTED TO FANS, FAN CASINGS AND FAN PLENUMS BY MEANS OF FLEXIBLE CONNECTORS FLEXIBLE CONNECTORS SHALL BE NEOPRENE COATED GLASS CLOTH CANVAS CONNECTIONS, DURO —DYNE, ELGEN, VENTFABRIC OR EQUAL. FLEXIBLE CONNECTORS SHALL HAVE A FLAME SPREAD OF 25 OR LESS AND SMOKE DEVELOPED RATING NOT HIGHER THAN 50. MAKE AIRTIGHT JOINTS AND INSTALL WITH MINIMUM 1 -1/2" SLACK. PROVIDE BALANCING DAMPERS, MANUFACTURED BY RUSKIN, GREENHECK, NAILOR INDUSTRIES, CESCO, LOUVERS & DAMPERS, POTTORFF OR APPROVED EQUAL, WHERE SHOWN ON DRAWINGS AND WHEREVER NECESSARY FOR COMPLETE CONTROL OF AIR FLOW. ROUND VOLUME DAMPERS SHALL BE BUTTERFLY TYPE CONSISTING OF CIRCULAR BLADE MOUNTED TO A SHAFT. PROVIDE FLEXMASTER MODEL STO OR EQUAL 45 DEGREE RECTANGULAR /ROUND SIDE TAKEOFF FITTING FOR ROUND DUCTWORK BRANCH TAKEOFFS TO INDIVIDUAL AIR DEVICES. ROUND OR OVAL DUCTWORK SHALL BE SEMCO, UNITED, WESCO OR EQUAL, SHEETMETAL, WITH SMOOTH INTERIOR SURFACE, WITH LOW PRESSURE (DUCT PRESSURE CLASS UP TO AND INCLUDING 2" W.G.) ROUND DUCTWORK GAUGES PER THE FOLLOWING TABLE: SIZE 14" & UNDER 15A 2 -3 FLEXIBLE DUCT 15A 2 —.4__0_!__‘1._13__)E\/ ICES 15A 3 HVAC EQUIPMENT 15A 3 -1 CONDENSING UNITS 15A 3 -2 FAN COIL UNITS 15A 3 -3 REFRIGERANT PIPING AND INSULATION GAUGE 26 LOW PRESSURE (DUCT PRESSURE CLASS UP TO AND INCLUDING 2" W.G.) AND MEDIUM PRESSURE (DUCT PRESSURE CLASS 2.1" TO 6" W.G.) FLEXIBLE DUCT SHALL BE FLEXMASTER TYPE 8, THERMAFLEX TYPE G —KM, OR EQUAL ( FIRE RETARDANT POLYETHYLENE) PROTECTIVE VAPOR BARRIER, U.L181 CLASS 1, ACOUSTICAL INSULATED DUCT 2" (R -6.0) FIBERGLASS INSULATION. PROVIDE CPE LINER WITH STEEL WIRE HELIX MECHANICALLY LOCKED OR PERMANENTLY BONDED TO THE LINER. FLEXIBLE DUCT RUNS SHALL NOT EXCEED 5 FEET IN LENGTH, AND SHALL BE INSTALLED STRAIGHT AS POSSIBLE AVOIDING TIGHT TURNS. CONNECT EACH END WITH STAINLESS STEEL SCREW OPERATED METAL DRAWBAN DS. FOR AIR DEVICES NOT PROVIDED BY OWNER, AS SCHEDULED ON DRAWINGS, SELECT TO LIMIT ROOM NOISE LEVEL TO N E NO HIGHER THAN NC-30 UNLESS OTHERWISE SHOWN. PROVIDE DEVICES WITH A SOFT PLASTIC GASKET TO MAKE AN AIRTIGHT SEAL AGAINST THE MOUNTING SURFACE. COORDINATE FINAL LOCATION, FRAME, AND MOUNTING TYPE OF AIR DEVICES WITH ARCHITECTURAL REFLECTED CEILING PLANS. PROVIDE SPLIT SYSTEM, AIR COOLED CONDENSING UNITS AS SCHEDULED ON THE DRAWINGS, MANUFACTURED BY CARRIER, COMPLETE WITH FACTORY INSTALLED HERMETIC OR SEMI — HERMETIC MOTOR /COMPRESSOR ASSEMBLY WITH INTERNAL SPRING VIBRATION ISOLATION, BUILT —IN THERMAL OVERLOAD PROTECTION, AND CRANKCASE HEATER; TOP DISCHARGE CONDENSER FAN AND MOTOR LOW AMBIENT CONTROLS FOR OPERATION TO 0'F; ANTI —SHORT CYCLE TIMERS; TIME DELAY RELAYS; FACTORY INSTALLED LIQUID LINE DRIER AND LOW PRESSURE SWITCH; FULL REFRIGERANT HOLDING CHARGE; AND WEATHERTIGHT HOUSING CONSTRUCTED OF ZINC COATED, HEAVY GAUGE, GALVANIZED STEEL WITH WEATHER — RESISTANT BAKED ENAMEL FINISH AND FACTORY INSTALLED CONDENSER COIL GUARDS. UNIT SHALL CARRY A FIVE YEAR GUARANTEE ON THE COMPRESSOR AND REFRIGERANT CIRCUIT, AND A ONE YEAR GUARANTEE ON THE REMAINING COMPONENTS. PROVIDE SPLIT SYSTEM, FAN COIL UNITS AS SCHEDULED ON THE DRAWINGS, MANUFACTURED BY CARRIER, CONFIGURATION COMPLETE WITH ZINC COATED, HEAVY GAUGE, GALVANIZED STEEL CABINET WITH WEATHER — RESISTANT BAKED ENAMEL FINISH; INTERNALLY INSULATED; ACCESS DOORS; DIRECT EXPANSION COOLING COIL SECTION OF ALUMINUM /COPPER CONSTRUCTION; CONDENSATE DRAIN PAN; STATICALLY AND DYNAMICALLY BALANCED CENTRIFUGAL FAN SECTION WITH BUILT —IN MOTOR THERMAL OVERLOAD PROTECTION; FACTORY INSTALLED AND WIRED CONTROLS AND SINGLE POINT ELECTRICAL POWER CONNECTION; MAGNETIC MOTOR STARTERS AND CONTACTORS AS REQUIRED; AIR FILTER RACK WITH 1" THICK THROWAWAY FILTERS; FACTORY INSTALLED ELECTRIC HEATING COIL WITH CODE REQUIRED INTEGRAL SAFETY FEATURES AND CONTROLS. PROVIDE SPRING VIBRATION ISOLATORS AND ALL — THREAD HANGING RODS FOR HORIZONTAL INSTALLATIONS. PROVIDE ASTM B 88, TYPE L OR ASTM B 280, TYPE ACR HARD DRAWN COPPER REFRIGERANT PIPING, CLEANED AND SEALED AT THE FACTORY, AND SPECIFICALLY DESIGNED FOR REFRIGERANT. FITTINGS SHALL BE HARD DRAWN AND HAVE LONG RADIUS TURNS. SOLDER JOINTS WITH "SILFOS" (15 PERCENT SILVER, 5 PERCENT PHOSPHORUS, 80 PERCENT COPPER, 1300 DEGREES FAHRENHEIT FLOW TEMPERATURE). SOLDER JOINTS WITH A SLOW STREAM OF DRY NITROGEN PASSING THROUGH THE PIPING. INSULATE SUCTION LINES WITH 3/4" FOAMED PLASTIC INSULATION, ARMAFLEX OR EQUAL. PIPING INSULATION SHALL HAVE A FLAME SPREAD OF 25 OR LESS, AND A SMOKE DEVELOPED RATING OF 50 OR LESS WHEN TESTED IN ACCORDANCE WITH ASTM E84. COAT INSULATION THAT IS EXPOSED TO THE ELEMENTS WITH A PROTECTIVE SEALER. INSTALL AND SUPPORT PIPING TO KEEP NOISE AND VIBRATION TO A MINIMUM. SUPPORT AND SECURE PIPING TO UNISTRUT TYPE SUPPORTS SO THAT NO VIBRATION PASSES TO THE BUILDING STRUCTURE. PIPE ATTACHMENTS SHALL BE COPPER— PLATED OR HAVE NONMETALUC COATING FOR ELECTROLYTIC PROTECTION WHERE ATTACHMENTS ARE IN DIRECT CONTACT WITH COPPER TUBING. INSTALL A SUPPORT WITHIN ONE FOOT OF EACH CHANGE OF DIRECTION. MOUNT PIPE HANGERS AROUND THE OUTSIDE OF THE INSULATION WITH SADDLES TO PREVENT HANGERS FROM RUPTURING THE INSULATION. REPLACE INSULATION THAT IS CUT OR BROKEN BY THE HANGERS. RUN REFRIGERANT LINES PARALLEL AND PERPENDICULAR TO WALL AND FLOOR LINES AND TO APPEAR STRAIGHT AND IN GOOD ORDER. PITCH SUCTION LINES DOWN SLIGHTLY (1" IN 20') TOWARDS THE COMPRESSOR. PROVIDE OIL TRAPS AT THE BASE OF VERTICAL SUCTION RISERS OVER 6 FEET HIGH. INSTALL LIQUID LINE SIGHT GLASSES IN UQUID LINES NEAREST THE CONDENSING UNITS. FACTORY MOUNT EXPANSION VALVES WITH THE SENSING BULBS SHIPPED LOOSE. FIELD MOUNT EXPANSION VALVE BULB AFTER REFRIGERANT PIPING IS COMPLETE (DAMAGE MAY OCCUR IF BULBS COME IN CONTACT WITH HEAT). FOR SYSTEMS OF 5 TON CAPACITY AND SMALLER, THE CONTRACTOR SHALL HAVE THE OPTION TO PROVIDE COPPER REFRIGERANT TUBING UNE SET SIZED AS RECOMMENDED BY EQUIPMENT MANUFACTURER AND OF LENGTH AS REQUIRED FOR THE INSTALLATION. PROVIDE 3/4" THICK FOAMED PLASTIC INSULATION, ARMAFLEX OR EQUAL, ON THE SUCTION LINE. PROVIDE QUICK — CONNECT FLARE TUBING COMPRESSION FITTINGS OR SOLDER CONNECTIONS AS REQUIRED TO MATCH THE CONNECTIONS OF THE CONDENSING UNIT AND EVAPORATOR COIL 15A 3 -4 SYSTEM EVACUATION AND CHARGING BLOW OUT REFRIGERATION LINES WITH DRY NITROGEN AT A SUITABLE PRESSURE BEFORE MAKING FINAL CONNECTION AT THE CONDENSING UNIT OR COIL TO ENSURE AGAINST DIRT, SCALE, OR OTHER FOREIGN MATERIAL BEING IN THE LINES. DRAW A VACUUM TO 29" OF MERCURY. BREAK THIS VACUUM BY CHARGING DRY REFRIGERANT GAS INTO THE SYSTEM, RAISING THE PRESSURE TO 0 PSIG. REPEAT THE LATTER TWO STEPS FOR A TRIPLE EVACUATION BEFORE THE FINAL EVACUATION IS STARTED. MAKE FINAL EVACUATION BY REDUCING THE SYSTEM ABSOLUTE PRESSURE TO A MAXIMUM OF 0.5 MILLIMETERS (500 MICRONS) AND ALLOWING THE PUMP TO RUN AT THIS PRESSURE FOR A MINIMUM OF TWO HOURS. REPEAT THE PROPER AMOUNT OF REFRIGERANT CHARGE PER THE MANUFACTURER'S RECOMMENDATIONS. RECORD THE AMOUNT OF REFRIGERANT BY WEIGHT CHARGED INTO THE SYSTEM FOR EACH CIRCUIT RECORDED TO THE NEAREST 1/4 POUND ON TAGS AND ATTACH TAGS TO THE UQUID LINE NEAR THE CONDENSING UNIT. REFRIGERANT SHALL BE SUPPLIED BY THE HVAC CONTRACTOR. 15A 3 -5 FAN POWERED BOXES. PROVIDE E.H. PRICE, TITUS, CARNES, KREUGER OR ENVIRONMENTAL TECHNOLOGIES PRESSURE INDEPENDENT VARIABLE VOLUME FAN POWERED TERMINAL BOXES AS NOTED AND SCHEDULED ON THE DRAWINGS. CONSTRUCT BOX CASING OF 22 GAUGE ZINC COATED STEEL, INTERNALLY LINED WITH 3/4 INCH THICK DUAL DENSITY FIBERGLASS INSULATION THAT COMPLIES WITH UL 181 AND NFPA -90A. CONSTRUCT THE PRIMARY AIR VALVE DAMPER OF METAL WITH PERIPHERAL GASKET PIVOTING IN SELF — LUBRICATING BEARINGS. WHEN CLOSED, THE DAMPER LEAKAGE SHALL NOT EXCEED 2 PERCENT OF THE RATED CFM AT 3" INLET STATIC PRESSURE. SET MINIMUM POSITION OF DAMPER AT THE FACTORY AND ALLOW FIELD ADJUSTMENT. CONSTRUCT FAN BLOWER OF STEEL WITH FC BLADES, DYNAMICALLY BALANCED WHEELS AND DIRECT DRIVE MOTOR. PROVIDE PERMANENT SPLIT CAPACITOR TYPE MOTORS WITH LUBRICATED BEARINGS AND THERMAL OVERLOAD PROTECTION. DESIGN MOTOR FOR USE WITH ELECTRONIC FAN SPEED CONTROLLER. PROVIDE ISOLATION BETWEEN MOTOR AND BLOWER ASSEMBLY. PROVIDE AN ELECTRONIC SPEED CONTROLLER WHICH ALLOWS CONTINUOUSLY ADJUSTABLE FAN SPEED FROM MAXIMUM TO MINIMUM. PROVIDE BOX WITH A BACKDRAFT DAMPER, FILTER AND FILTER FRAME, AND DIRECT DIGITAL CONTROLS. INCORPORATE A SINGLE POINT ELECTRICAL CONNECTION WITH ELECTRICAL COMPONENTS ENCLOSED IN A SINGLE CONTROL BOX WITH AN ACCESS PANEL SEALED FROM PRIMARY AIR FLOW. PROVIDE ELECTRIC RESISTANCE HEATING COILS OF OPEN COIL CONSTRUCTION WITH 80 PERCENT NICKEL, 20 PERCENT CHROMIUM. PROVIDE NEMA 1 CONTROL PANEL, ALUMINIZED OR GALVANIZED STEEL FRAME, AIRFLOW SWITCH, THERMAL OVERLOAD PROTECTION AND MERCURY CONTACTORS. 15A 4 TEMPERATURE CONTROLS 15A 4 -1 GENERAL REQUIREMENTS PROVIDE A SYSTEM OF TEMPERATURE CONTROLS INCLUDING THERMOSTATS, CONTROL PANELS, TIME SWITCHES, OVERRIDE TIMERS, DAMPER MOTORS, AND RELAYS REQUIRED TO PROVIDE THE DESIRED SEQUENCE OF OPERATION. PROVIDE INTEGRATED WIRING DIAGRAMS INTERCONNECTIONS AGRAMS SHOWING I BETWEEN FIELD INSTALLED EQUIPMENT AND PACKAGE WIRING FURNISHED WITH THE HVAC EQUIPMENT. PROVIDE SUPERVISION AND ON —JOB CHECKOUT SERVICE AS REQUIRED TO ENSURE THAT INSTALLATION MEETS REQUIREMENTS OF THE SPECIFICATION. THE SYSTEM SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FOLLOWING THE ACCEPTANCE OF THE SYSTEM BY THE ARCHITECT /ENGINEER. CORRECT DEFECTS OCCURRING DURING THIS PERIOD AT NO ADDITIONAL COST TO THE OWNER. 15A 4 -2 EQUIPMENT MANUFACTURERS AND MODEL NUMBERS ARE LISTED FOR REFERENCE AS TO QUALITY AND FEATURES REQUIRED FOR THE CONTROL DEVICES. PROVIDE CONTROL DEVICES BY BARBER — COLMAN, HONEYWELL, JOHNSON CONTROLS, TRANE OR WHITE RODGERS WITH QUALITY AND FEATURES AS INDICATED. LOW VOLTAGE TYPE DAY THERMOSTATS WITH SEPARATE SET POINTS FOR HEATING AND COOUNG SHALL BE HONEYWELL SERIES T8400 OR EQUAL, WITHOUT SUBBASE SWITCHES. INSTALL THERMOSTATS AT 48" AFF TO MEET ADA REQUIREMENTS UNLESS OTHERWISE NOTED ON THE PLANS. PROVIDE DUCT TYPE SMOKE DETECTORS WITH UL LISTING (OR HEAT DETECTORS, IF PERMITTED BY CODE) FOR EACH UNIT TO SHUT DOWN SUPPLY FAN UPON ACTIVATION. 15A 5 SEQUENCE OF OPERATION 15A5 -1 FAN POWERED REHEAT TERMINAL UNIT CONTROL THE UNIT FAN SHALL OPERATE CONTINUOUSLY. UPON A RISE IN SPACE TEMPERATURE ABOVE COOLING SET POINT (70 DEGREES FAHRENHEIT), THE TERMINAL UNIT SHALL MODULATE PRIMARY AIR FLOW TO MAINTAIN COOLING SET POINT. UPON A DROP IN SPACE TEMPERATURE, THE UNIT SHALL MODULATE TO THE MINIMUM COOUNG AIR FLOW. AS THE SPACE TEMPERATURE CONTINUES TO FALL BELOW SET POINT, THE UNIT SHALL MODULATE THE PRIMARY AIR FLOW TO THE MINIMUM AIR FLOW AND ENABLE THE HEATING COIL STAGE ON THE ELECTRIC HEAT TO MAINTAIN SET POINT (68 DEGREES FAHRENHEIT). TENANT'S CONTROLS CONTRACTOR TO PROVIDE INPUT /OUTPUT POINTS AS REQUIRED BY THE LANDLORD FOR COMMUNICATION WITH THE BUILDING AUTOMATION SYSTEM. 15A 5 -2 FAN COIL UNIT CONTROL THE FAN COIL UNIT IS TO BE OPERATED AS A SUPPLEMENTAL SYSTEM FOR AFTER HOURS CONDITIONING ONLY. CYCLE STAGE(S) OF COOUNG TO MAINTAIN ROOM THERMOSTAT SET POINT (70 DEGREES FAHRENHEIT COOLING). A DUCT MOUNTED SMOKE DETECTOR SHALL SHUTDOWN UNIT UPON ALARM. OB.-011 RECEA FEB - 8 20U6 PERMIT GEN I L 10370 RICHMOND AVENUE, SUITE 370 HOUSTON, TX 77042 TEL 713 783 7707 FAX 713 783 7797 www.hei- eng.cem 0750001294 R15 JMH SIM HENDERSON ENGINEERS =_ 0 O V 98% OWNER REVIEW HEALTH DEPT RVSNS ISSUED FOR PERMIT M -4.0 Id a u ISSUED / REVISED DATE HEALTH DEPT SUBMITTAL 12.17.07 01.03.08 01.11.08 01.25.08 MECHANICAL SPECIFICATIONS Cooling Equipment Schedule Equip. ID Brand Name Model No. Capacity Btu/h Total CFM OSACFM or Econo? SEER or EER IPLV Location 3ca/ - 1 . C RRIER FA4CHF024 /24a3RS24 19900 835 1/AV 13.00 Pkg. elec. htg.& cig. List heat pumps on schedule yea 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency n.a. 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans yes 1412.2 Deadband control Indicate 5 degree deadband minimum n.a. 1412.3 Humidity control Indicate humidistat n.a. 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types n.a. 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage Fan Equipment Schedule Equip. ID Brand Name Model No. CFM Sp HP/BHP Flow Control Location of Service vav -1 TITos DTQS 1035 0.35 0.25 1/AV rate -lA Pkg. elec. htg.& cig. List heat pumps on schedule yea 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency n.a. 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans yes 1412.2 Deadband control Indicate 5 degree deadband minimum n.a. 1412.3 Humidity control Indicate humidistat n.a. 1412.4 Automatic setback Heating Equipment Schedule Equip. ID Brand Name Model No. Capacity Btu/h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency'' ❑ <70% outside air? 0.70 14i1 ui ent t=q tm1 pe rformance a -a. 1411.4 Pkg. elec. htg.& cig. List heat pumps on schedule yea 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency n.a. 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans yes 1412.2 Deadband control Indicate 5 degree deadband minimum n.a. 1412.3 Humidity control Indicate humidistat n.a. 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types n.a. 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage Project Info Project Address endive chocolatier - Southcenter Mali Date 1/24/2008 633 southcenter, Suite 1020 For Building Dept. Use Seattle, WA 98188 Applicant Name: Applicant Address: Applicant Phone: Project Info Project Address aodiva Chocolatiar - Southeenter Mall Date 1/24/200e 633 Southcenter, Suite 1020 For Building Department Use Seattle, WA 98188 Applicant Name: Applicant Address: Applicant Phone: System Description See Section 1421 for full description of Simple System qualifications. If Heating/Cooling or Cooling Only: ❑ Constant vol? Split system? ❑ Air cooled? • Packaged sys? ❑ <20,000 Btuh? ❑ Economizer included? E i If Heating Only: II <5000 chi? ❑ <70% outside air? Mechanical Permit Plans ens Checklist :: . ; : ; � : ; : : - : :: 2006 Washington State Nonresidential Energy Code Compliance Farms EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 Mechanical Permit Plans ens Checklist :: . ; : ; � : ; : : - : :: 2006 Washington State Nonresidential Energy Code Compliance Farms : MECH -CI-1K Revisal July 200T Project Address Godiva Chocolatier - Southcenter Mall (Date 1/24/2008 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department ' Notes HVAC REQUIREMENTS (Sections 1401 - 1424) 14i1 ui ent t=q tm1 pe rformance a -a. 1411.4 Pkg. elec. htg.& cig. List heat pumps on schedule yea 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency n.a. 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans yes 1412.2 Deadband control Indicate 5 degree deadband minimum n.a. 1412.3 Humidity control Indicate humidistat n.a. 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types n.a. 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage n.a. 1412.4.2 Optimum Start Indicate optimum start controls a.a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule n.a. 1412.6 Combustion htg. Indicate modulating or staged control yes 1412.7 Balancing Indicate balancing features on plans 1412.8 Ventilation Control indicate demand control ventilation for high -occupancy areas n.a. 1422 Thermostat interlock Indicate thermostat Interlock on plans n - 1423 Economizers Equipment schedule 1413 Air economizers n.a. 1413.1 Air Econo Operation Indicate 100% capability on schedule a. a. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb n. a. 1413.2 Water Econo Doc Indicate dg load & water econoe & cig tower performance a. a. 1413.3 integrated operation Indicate capability for partial cooling n.a. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary yes 1414.2 Duct insulation Indicate R -value of insulation on duct yes 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements n.a. 1416.21 Commissioning Provide commissioning plan yes 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing yes 1416.24 Commissioning Indicate O&M manuals, record drawings, staff training n.a. 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report yes 1434 Separate air sys. Indicate separate systems on plans yes Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 - 1454) 1440 Service water htg. yes 1441 Elec. water heater Indicate R -10 insulation under tank yes 1442 Shut -off controls Indicate automatic shut -off yes 1443 Pipe Insulation Indicate R -value of insulation on piping r1.a. 1452 Heat Pump COP Indicate minimum COP of 4.0 a. a . 1452 Heater Efficiency Indicate pool heater efficiency n.a. 1453 Pool heater controls Indicate switch and 65 degree control a. a . 1454 Pool covers Indicate vapor retardant cover a.a. 1454 Pools 90+ degrees Indicate R -12 pool cover 1 2 3 2006 Washington State Nonresidential Energy Code Cempriance Forms 2006 Washington State Nonresidential Energy Code Compliance Form Project Summary PRJ -SUM 2006 Washington State Nonresidential Energy Code Compliance Form no is circled for any question, provide explanation: Revised July 2007 4 5 6 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary Washington State Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. Includes Plans Drawings must contain notes requireing compliance with commissioning requirements - Section 1416 Revised Any 2007 Compliance Option © Simple System 0 Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. 1 if available. 2 As tested according to Table 14-1A through 14-1 G. 3 If required. 4 COP, HSPF Combustion Efficiency, or AFUE, as applicable. 5 How control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). ., 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14-10. If a nationally recognized certification program exists for a product covered in Tables 14-1A through 14-1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -ired forced air furnaces with input ratings a 225,000 Btuni (65 kW) and all unit heaters shall also have an intermittent ignition or Interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings a 225,000 Stunt (65 kW), including electric furnaces, That are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cool equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall b be furnished y the equipment m anufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal funon of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActar (EF) or a CAE of riot less than the following: 1411.4 Packaged Electric Heating and Coo ing Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu /h shag be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 5. Thermostats that require manual changeover between heating and cooing modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Offs IiVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week It must retain programming and time for a power loss of 1 0 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint 2. Equipment with full load demands of 2 kW (6,826 Bluth) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controfled by an occupant sensor that Is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air Intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes_ 3. Gravity (nonmotodzed) dampers are acceptable in buildings less than 3 stories In height 4. Gravhy (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories in height 14114.2 Optimum Start Controls: Heating and coofing systems with design supply 1412.8 Ventilation Controls for High - Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or C. A design outdoor airflow greater than 3000 cfm. tions: 1.Systems Excep with energy recovery complying with Section 1436. 2_ Multiple -zone systems wilhout direct - digital control of individual zones communicating with a central control paneL 3. Systems with a design outdoor airflow less than 1200 cfm. 4_ Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement Is -tens than 1200 cfm. 1413 A ir Economize 1 413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the connoted terminal equipment lacking airside economizer, at outside air temperatures of 45 dry-bulb/40 wet -bulb and below. For this calculation. all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide fug cooling. 2. Design cooing load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooing load. Exceptions: 1. Individual, direct expansion was that have a rated capacity less than 65,000 Btu/h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooing. 2 Water- cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAG 246-320 -525 allows only steam Injection humidifiers in ductwork downstream of final fitters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which Is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed In accordance with Standard RS -18. Extent of sealing required is' as follows: 1. Static pressure: 112 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse feints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 Inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating Interior space from exterior space, shall meet all appicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and bending envelope insulation levels. Unheated equipment rooms with combustion air louvers must be Isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shag be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered huiding envelope until they, 1, connect to the heating or coofing equipment, or 2. are isolated from the exteriorwith an automatic shut -off damper complying 7 8 2006 Washington State Nonresidential Energy Code Compliance Form 9 Mechanical Summary (back) :. Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. if not, either the Complex System or Systems Analysis Options must be used. START Heating Only I Complex Systems r Reference Section 1421 otal Ca.. wo economize <240,000 Btuh r10 %? Heating /Cooling or Cooling Only Simple System Mowed (section 1420) Yes Refer Section 1423 Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. 2000 Washington State Nonresidential Energy Code Compliance Form 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 2. are isolated from the exterior with an automatic shut -off damper complying air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum with Sermon 1412 4,1. start controls shall be designed to automatically adjust the start time of an HVAC Once outside air ducts meet the above listed requirements, any runs within system each day to bring the space to desired occupied temperature levels conditioned space shalt comply with Table 14-5 requirements. immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start -up, set- up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first siege of heat. Controls shall indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225.000 Btuih shall have modulating or staged combustion control. 000 EXCEPTIONS: 1. Boilers. 2. Radiant heaters. 1412.7 Balancing: Each air supply outlet er air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. Other ducts and plenums shall be thermally insulated per Table 14-5. Exceptions: 1. Within the HVAC equipment 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1415 Piping Systems 1415.1 Insulation: Piping shag be thermally insulated in accordance with Table 14-6. Exception: Piping Installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated In accordance with Washington State Plumbing Code (WAC 51 -26) 1416 Completion Requirements (Refer to NREC Section 1416 and the Building Commissioning Guidelines, published by the Braiding Commissioning Association, for complete text and guidelines for building completion and commissioning requirements.) PBS 10 REC.;:r FEB -8 2i1Ud PERM! 1 utt \I HENDERSON ENGINEERS= 10370 RICHMOND AVENUE, SUITE 370 HOUSTON, TX 77042 TEL 713 783 7707 FAX 713 783 7797 www.hei eng.coni 0750001294 RJS 1MH SIM EXR n /07/08 D 0 ISSUED / REVISED DATE 98% OWNER REVIEW HEALTH DEPT RVSNS ISSUED FOR PERMIT HEALTH DEPT SUBMITTAL 12.17.07 01.03.08 01.11.08 01.25.08 MECHANICAL ENERGY FORMS M -5.0 LIGHT FIXTURE SCHEDULE ELECTRICAL S Y M B C LS NOT I NOTE: ABBREVIATIONS, ETC. E ARE D NECE D S5 M ON L THE DRAWINGS. RILY USED VOLTAGE ELECTRICAL ONE -LINE & RISER CIRCUITING & WIRING WIRING DEVICES & OUTLETS B2 7 5 3 HOMERUN TO PANELBOARD, ARROWS INDICATE NUMBER OF CIRCUITS, HASH MARKS INDICATE NUMBER OF CONDUCTORS. OR P INFORMATION AT ARROWS ARE CIRCUIT NUMBERS AND P1 -3,5,7 PANELBOARD. (GREEN INSULATION OR BARE) EQUIPMENT GROUNDING CONDUCTOR IN CONDUIT ..-- --4--- 1 ISOLATED GROUNDING CONDUCTOR IN CONDUIT (GREEN INSULATION WITH YELLOW TRACER) .--------. CONDUIT CONCEALED - CONDUIT IN /UNDER FLOOR /GROUND CONSTRUCTION - - - - EXPOSED CONDUIT /� _ �_ FLEXIBLE CONDUIT ..... -`^ -� LOW VOLTAGE CABLE 7 CONDUIT TURNING DOWN �' (((� $ z U ` (') ,}µ, WY U5 0 CI] 6 SINGLE POLE WALL SWITCH (NO LETTER DESIGNATION) SWITCH LETTER DESIGNATIONS AS FOLLOWS: 2 =TWO POLE WALL SWITCH 3 - THREE -WAY WALL SWITCH 4 = FOUR-WAY WITCII D = DIMMER TYPE WALL OS = OCCUPANCY SENSOR SWITCH K = KEYED SWITCH M = MOTOR RATED SWITCH CEILING MOUNTED OCCUPANCY SENSOR WITH POWER SUPPLY j \// AND LOAD RELAY AS REQUIRED OR SPECIFIED. SIMPLEX RECEPTACLE - NEMA 5 -20R, UNO DUPLEX RECEPTACLE - NEMA 5 -20R, UNO DOUBLE DUPLEX RECEPTACLE - NEMA 5 -20R, UNO HEAVY DUTY RECEPTACLE - NEMA TYPE AS NOTED TWIST -LOCK TYPE RECEPTACLE RECEPTACLE INSTALLED 6" ABOVE COUNTER OR BACKSPLASH CEILING MOUNTED DUPLEX RECEPTACLE FLOOR MOUNTED DUPLEX RECEPTACLE ISOLATED GROUND (DUPLEX RECEPTACLE, SIMILAR FOR OTHERS) RECEPTACLE INSTALLED VIA DROP CORD GFCI RECEPTACLE LETTER DESIGNATIONS AS FOLLOWS: C = CLOCK HANGER TYPE E = EMERGENCY POWER S = SWITCHED IG = ISOLATED GROUND GFCI = GROUND FAULT CIRCUIT INTERRUPTER TR = TAMPER RESISTANT WP = WEATHERPROOF _ MULTI - OUTLET SURFACE RACEWAY WITH NEMA 5 -20R 2 -LAMP T4 METAL HALIDE SEMI - RECESSED, ADJUSTABLE FIXTURE. 1 PANELBOARD (SEE SCHEDULES) AMERLUX MSRA- 39- T4 -E -WT- 120 ---NF- SUN -FLO (1) 39W T4 METAL HALIDE MULTI - SECTION PANELBOARD (SEE SCHEDULES) r 1TX# TRANSFORMER Fa - 1 TX# SHIELDED TYPE AND RATINGS I � i TRANSFORMER i L `�� j 1 I i AS SHOWN :771 � TYPE AND RATINGS AS SHOWN I 800A SWITCH I 225A CIRCUIT BREAKER 3P RATING AS SHOWN ( 3P RATINGS AS SHOWN 200A5 FUSED SWITCH 3P RATING,POLES AND 200AF FUSE TYPE AS SHOWN FRS SD E'I'1-'• CIRCUIT IDENTIFICATION - SEE CIRCUIT SCHEDULE 120V GFR GROUND FAULT RELAY 6" SQUARE LENSED DOWNLIGHT WITH T6 METAL HALIDE LAMP. CONDUIT TURNING UP ® SHUNT TRIP LR 4 r0 UTILITY METER (AS REQUIRED BY UTILITY) CURRENT TRANSFORMER RATING AS SPECIFIED OR REQUIRED -0 I CONNECTION POINT OR EQUIPMENT TERMINATION • EQUIPMENT TERMINATION 1 TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR •--III GROUND CONNECTION (D-I GROUND ROD = CONTACT (OPEN OR CLOSED) -w- HEATER O MOTOR LIGHTING A 120V o FLUORESCENT LIGHT FIXTURE: (SEE LIGHT FIXTURE SCHEDULE) 1 PA a a = SWITCHED BY SWITCH "a" A = LIGHT FIXTURE TYPE "A" p 120V/12V o ® 1,2 ## BLOCK LOAD KW OR KVA w=e=is 120 100W � . FLUORESCENT LIGHT FIXTURE WITH NIGHT LIGHT RECEPTACLES 12" ON CENTER, UNO. TELEPHONE OUTLET - FLOOR OR WALL MOUNTED. INSTALL LA AT SAME ELEVATION AS ADJACENT RECEPTACLE, UNO. DATA OUTLET - FLOOR OR WALL MOUNTED. INSTALL AT �I V SAME ELEVATION AS ADJACENT RECEPTACLE, UNO. MULTI- SERVICE OUTLET - FLOOR OR WALL MOUNTED. INSTALL °A v AT SAME ELEVATION AS ADJACENT RECEPTACLE, UNO. m , A MULTI - SERVICE POWER POLE WITH TELEPHONE, DATA AND POWER r.A OUTLETS A - TYPE, SEE SCHEDULE IN SPECIFICATIONS A MULTI- SERVICE FLOOR BOX WITH TELEPHONE, DATA AND POWER 0 OUTLETS A = TYPE, SEE SCHEDULE IN SPECIFICATIONS Qo A POKE THROUGH, A = TYPE, SEE SCHEDULE IN SPECIFICATIONS CD THERMOSTAT 0 JUNCTION BOX /OUTLET BOX ffl JUNCTION BOX /OUTLET BOX SIGNALING F32T8/TL835 120V 58W 2 -LAMP LINEAR WIDE CHANNEL LIGHT FIXTURE WITH PLASTIC TUBE GUARD FOR LAMPS. B T • SIGNALING BELL SIGNALING BUZZER LV TRANSFORMERS COOPER - ATLITE TSC16RWSA •.£` ` FLUORESCENT LIGHT FIXTURE WITH EMERGENCY LIGHTING BATTERY PACK FLUORESCENT LIGHT FIXTURE WITH DUAL BALLASTS CIRCUITED EDGELIT EXIT SIGN 1 SEPARATELY. ( SHADING IMPLIES EMERGENCY BALLAST WITH BATTERY PACK) A V V v ABBREVIATIONS A AMPERES, AIR (COMPRESSED) A/C AIR CONDMONING Al: AMPERE FUSE AFC ABOVE FINISHED CEILING AFC] ARC FAULT CIRCUIT INTERRUPTER AFEA AREA FOR EVACUATION ASSISTANCE AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AI ANALOG INPUT AIC AMPERE INTERRUPTING CURRENT AL ALUMINUM AO ANALOG OUTPUT AP ACCESS PANEL ATS AUTOMATIC TRANSFER SWITCH AWG AMERICAN WIRE GAUGE BAS BUILDING AUTOMATION SY51LM BFF BELOW FINISHED FLOOR BFG BELOW FINISHED GRADE BI BINARY INPUT BKR BREAKER BO BINARY OUTPUT C CONDUIT CD CANDELA CT CURRENT TRANSFORMER CAN CABLE TELEVISION SYSTEM CCTV CLOSED CIRCUIT TELEVISION CKT CIRCUIT CPT CONTROL POWER TRANSFORMER CU COPPER, CONDENSING UNIT CVD CUMULATIVE VOLTAGE DROP DDC DIRECT DIGITAL CONTROL DI DIGITAL INPUT, DUCTILE IRON DN DOWN DPDT DOUBLE - POLE, DOUBLE - THROW DPST DOUBLE -POLE, SINGLE -THROW EM EMERGENCY EPO EMERGENCY POWER OFF ETR EXISTING TO REMAIN FACP FIRE ALARM CONTROL PANEL FBO FURNISHED BY OTHERS /OWNER FCA FAULT CURRENT AMPS FF FINISHED FLOOR FLA FULL LOAD AMPS FLR FLOOR FVNR FULL- VOLTAGE, NON - REVERSING GC GENERAL CONTRACTOR GFCI GROUND FAULT CIRCUIT INTERRUPTER GFR GROUND FAULT RELAY G GROUND GND GROUND GRS GALVANIZED RIGID STEEL HOA HAND -- OFF - AUTOMATIC IG ISOLATED GROUND ISC SHORT CIRCUIT CURRENT JB JUNCTION BOX J -BOX JUNCTION BOX kcmil 1000 CIRCULAR MILS KK KIRK KEY kV KILOVOLT kVA KILOVOLT -AMPS kVAR KILOVOLT -AMPS REACTIVE kW KILOWATT kWH KILOWATT - HOUR LE LINEAR FEET MAW MASTER ANTENNA TELEVISION SYSTEM MAX MAXIMUM MCA MINIMUM CIRCUIT AMPACITY MCB MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MD MOTORIZED DAMPER MDP MAIN DISTRIBUTION PANEL MFR MANUFACTURER MG MOTOR GENERATOR MH MANHOLE MIN MINIMUM MLO MAIN LUGS ONLY MOCP MAXIMUM OVERCURRENT PROTECTION MSB MAIN SWITCHBOARD MSWB MAIN SWITCHBOARD MS/TP MASTER SLAVE /TOKEN PASSING - COMMUNICATION TRUNK MTD MOUNTED N/A NOT APPLICABLE N/C NORMALLY CLOSED NIC NOT IN CONTRACT NL NIGHT UGHT N/O NORMALLY OPEN OC ON CENTER OS OCCUPANCY SENSOR PDU POWER DISTRIBUTION UNIT PH, 0 PHASE PD./ POST INDICATOR VALVE PNL PANEL PNLBD PANELBOARD PROVIDE FURNISH AND INSTALL PT POTENTIAL TRANSFORMER PTZ PAN, TILT, ZOOM QTY QUANTIFY RCPT RECEPTACLE RLA RUNNING LOAD AMPS RTU ROOFTOP UNIT SD SMOKE DETECTOR, SUPPLY DUCT SF SQUARE FEET, SUPPLY FAN SPOT SINGLE -POLE, DOUBLE -THROW SPST SINGLE - POLE, SINGLE - THROW 5S STAINLESS STEEL, SANITARY SEWER, SOIL STACK ST SHUNT TRIP, STEAM TRAP SWBD SWITCHBOARD TL TWISTLOCK TR TAMPER RESISTANT TX TRANSFORMER TYP TYPICAL u/F UNDERFLOOR U/G UNDERGROUND UH UNIT HEATER U/S UNDERSLAB UL UNDERWRITERS LABORATORIES, INC. UNO UNLESS NOTED OTHERWISE UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT(5) VAC VOLTS ALTERNATING CURRENT VD VOLTAGE DROP VbC VOLTS DIRECT CURRENT VFD VARIABLE FREQUENCY DRIVE W WIRE WP WEATHERPROOF XP EXPLOSION - PROOF LIGHTING TRACK WITH LIGHT FIXTURE TYPES AS INDICATED 0A LIGHT FIXTURE - CEILING / WALL MOUNTED. g A = LIGHT FIXTURE TYPE "A" A WALL WASHER LIGHT FIXTURE - ARROW INDICATES DIRECTION. �/ A = LIGHT FIXTURE TYPE "A" A WALL MOUNTED LIGHT FIXTURE. A = LIGHT FIXTURE TYPE "A" (� T I1 SITE LIGHTING FIXTURE (SEE LIGHT FIXTURE SCHEDULE) G A EXIT SIGN - CEILING / WALL MOUNTED, ARROWS AS INDICATED. y A - LICHT FIXTURE TYPE "A" (SEE LIGHT FIXTURE SCHEDULE) � E MERGENCY BATTERY PACK LIGHT FIXTURE - CEILING /WALL MOUNTED. (SEE LIGHT FIXTURE SCHEDULE) IA1.4 EMERGENCY SHUNT RELAY POWER EQUIPMENT & DEVICES mom vow ELECTRICAL SERVICE PANELBOARD (SURFACE OR FLUSH MOUNT) TERMINAL CABINET (SURFACE OR =1= FLUSH MOUNT), TYPE AS NOTED PLYWOOD TERMINAL BOARD FOR TELEPHONE STANDARD MOUNTING HEIGHTS (AFF, AEG, UNLESS NOTED OTHERWISE) ELECTRICAL ALARMS 48" ANNUNCIATOR PANELS 48" CLOCK OUTLETS (CENTERLINE) 84" CONTROLS (CENTERLINE) 48" EXIT SIGNS (WALL MOUNTED, BOTTOM) 80" » INTERCOM (AFEA ONLY) 36" INTERCOMS 48" PANELS /PANELBOARDS (TOP) 72" PHOTOCELLS 144" RECEPTACLES (CENTERLINE) 18" RECEPTACLES (EXTERIOR) 24" RECEPTACLES (GARAGES) 26" RECEPTACLES IN EQUIPMENT ROOMS 48" REMOTE INDICATING LIGHT (EQUIPMENT ROOMS) 48" REMOTE INDICATING LIGHT (FINISHED AREAS) CEILING SAFETY SWITCHES 48" STARTERS 48 48" SWITCHES (CENTERLINE) 48" TELEPHONES (PUBLIC) 1 @ 48 ", 1 @ 36" TELEPHONE, DATA OUTLETS (CENTERLINE) 18" TELEPHONE TERMINAL BOARD (BOTTOM) 6" TELEVISION OUTLETS 18" , SYSTEM, UNO. SIZE AS NOTED. r // ELECTRICAL DISTRIBUTION PANELBOARD '� SWITCHBOARD OR MOTOR CONTROL CENTER ON HOUSEKEEPING PAD LIGHTALARMS ELF605P INCLUDED 120V TRANSFORMER 'Q' MOTOR 200/3/150 DISCONNECT SWITCH - "200/3/150" DENOTES ip AMPERES /POLE /FUSE NF= NON - FUSED CB= CIRCUIT BREAKER (200 /3 /CB) COMBINATION DISCONNECT (SAFETY) SWITCH AND 30/3/15/1 MOTOR STARTER "30/3/15/1" DENOTES AMPERES /POLE /FUSE /NEMA STARTER SIZE NF= NON - FUSED CB= CIRCUIT BREAKER (30/3/CB/1) MAGNETIC MOTOR STARTER, NEMA I� 2 SIZE AS NOTED. 3 - POLE, UNO. MS MANUAL STARTER VFD VARIABLE FREQUENCY DRIVE O RELAY OR CONTACTOR (IN SCHEMATICS) MAGNETIC CONTACTOR, SIZE, COIL VOLTAGE AND C L NUMBER OF POLES AS INDICATED (L= LIGHTING CONTACTOR, P= POWER CONTACTOR) ® TIME SWITCH PC PHOTOCELL INDICATING LIGHT • PUSH BUTTON ANNOTATION (C) 1 ELECTRICAL PLAN NOTE CALLOUT TECHNOLOGY PLAN CALLOUT 1 1 EQUIPMENT DESIGNATION (OWNER FURNISHED, CONTRACTOR INSTALLED) CONNECTION POINT OF NEW WORK TO EXISTING d DETAIL REFERENCE UPPER NUMBER INDICATES DETAIL NUMBER • • STOP - START PUSH BUTTON CONTROL STATION 46W ••• HAND - OFF - AUTO PUSH BUTTON CONTROL STATION NW LOWER NUMBER INDICATES SHEET NUMBER E"D MUSHROOM - TYPE PUSH BUTTON N. OVERHEAD PADDLE FAN SECTION CUT DESIGNATION LIGHT FIXTURE SCHEDULE TYPE MANUFACTURER /MODEL # LAMP VOLTAGE WATTS (VA) DESCRIPTION NOTES B2 AMERLUX MSRA- 2- 20- T4 -E -B- 120 --FL -W (2) 20W T4 METAL HALIDE 120V 40W 2 -LAMP T4 METAL HALIDE SEMI - RECESSED, ADJUSTABLE FIXTURE. 1 B2A AMERLUX MSRA- 39- T4 -E -WT- 120 ---NF- SUN -FLO (1) 39W T4 METAL HALIDE 120V 44W SINGLE LAMP T4 METAL HALIDE SEMI- RECESSED ADJUSTABLE FIXTURE. 1 SD AMERLUX SD6- 39- T6- E -SD -W- 120 -FL -SUN 39W T6 METAL HALIDE 120V 44W 6" SQUARE LENSED DOWNLIGHT WITH T6 METAL HALIDE LAMP. 1 SA AMERLUX SA6- 39- T6- E- SD-- W- 120 -FL -SUN 39W T6 METAL HALIDE 120V 44W 6" ADJUSTABLE SQUARE LENSED DOWNUGHT WITH T6 METAL HALIDE LAMP. 1 RA AMERLUX RA6- 39- T6-- E- SD- W- 120 -FL -SUN 39W T6 METAL HALIDE 120V 44W 6" ROUND ADJUSTABLE LENSED DOWN LIGHT WITH T6 METAL HALIDE LAMP. 1 PA BRUCK 220097MC/MP -76" 35W MR16 FLOOD 120V/12V 35W PENDANT FIXTURE WITH FLAT GLASS RING. FIXTURE INCLUDES 4" MONOPOINT CANOPY AND 75W LV TRANSFORMER. 1,2 PS BK LIGHTING INC. ST- 4- BLP- 13- 11- B -24 -C (2) 50W MR16 120 100W SURFACE MOUNT FIXTURES FOR EXTERIOR SIGNAGE ILLUMINATION, CLEAR LENS, HONEYCOMB BAFFLE, 24" FROM WALL. 1 SR MERCURY MM- 232- OCT ---C - ELB -UNI R & R PLASTIC TUBE GUARD - PAL40T6 F32T8/TL835 120V 58W 2 -LAMP LINEAR WIDE CHANNEL LIGHT FIXTURE WITH PLASTIC TUBE GUARD FOR LAMPS. 1 XC COOPER - ATLITE TSC16RWSA INCLUDED 120V 5W EDGELIT EXIT SIGN 1 XW LIGHTALARMS U- XQELR -DC INCLUDED 120V 5W LED EXIT SIGN 1 BP LIGHTALARMS 2P12Q1/L25 -M INCLUDED 120/277 12W 12V EMERGENCY LIGHTING FIXTURE WITH 25W HEADS AND 90 MINUTE BATTERY BACK -UP 1 CEH LIGHTALARMS ELF605P INCLUDED 120V 20W RECESSED GIMBALL EMERGENCY LIGHT, PLASTIC TRIM RING. PROVIDE 90 MINUTE BATTERY BACK -UP. PROVIDE 20W LAMPS IN LIEU OF SW LAMPS SUPPLIED WITH FIXTURES TO MEET EMERGENCY LIGHTING PHOTOMETRICS. 1 WMEH HIGHLITES HL -90 INCLUDED 120V/277V 10W EMERGENCY LIGHTING UNIT WITH (2) 5.4W HEADS AND 90MIN BATTERY BACK -UP, CEILING - MOUNTED WHERE APPLICABLE. 1 WC LITHONIA WC- 2- 25- MVOLT- GEBIOIS F25T8/TL835 120V 46W 3' -0" ALL PURPOSE WALL BRACKET CHANNEL WITH (2) 25W T8 LAMPS. 1 FC NUTONE 769RL 60W A19 120V 240W TOILET ROOM FAN /LIGHT COMBO. FIXTURE TO BE LABELED FROM FACTORY TO ACCEPT ONLY 60W LAMPS. 1 NOTES: 1. ALL LIGHT FIXTURES FURNISHED BY GODIVA VIA CAPITAL LIGHTING 2. BOTTOM OF PENDANT TO BE AT 6' -8" AFF. 3. NOT ALL FIXTURES SHOWN ON THIS SCHEDULE ARE PROVIDED ON EACH GODIVA STORE. 5 6 7 8 9 10 ELECTRICAL GENERAL NOTES: 1. FIELD VERIFY ALL CONDITIONS. 2. DESIGN DRAWINGS ARE SCHEMATIC. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. 3. CONTACT THE OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN. INCLUDE IN BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT AND /OR ENGINEER VIA OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTOR'S COST. 4. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND /OR ENGINEER VIA THE OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. 5. MINOR VARIATIONS DUE TO UNFORSEEN CONDITIONS THAT MAY EFFECT THE CONTRACTOR'S SCOPE OF WORK, REQUIRED FOR ACCOMPLISHING THE INTENT OF THIS DESIGN SHALL BE INCLUDED IN CONTRACTOR'S PRICING. 6. CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE ALL REQUIRED PERMITS. CONTRACTOR'S INSTALLATION SHALL CONFORM TO ALL LOCAL CODE REQUIREMENTS. 7. VERIFY EXACT PLACEMENT OF ALL DEVICES SHOWN OF THE ELECTRICAL CONSTRUCTION DOCUMENTS WITH ARCHITECTURAL, MECHANICAL AND PLUMBING DRAWINGS PRIOR TO FINAL PLACEMENT. 8. BECOME FAMILIAR WITH REQUIRED DEMOLITION WORK PRIOR TO BIDDING AND START OF WORK. CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE ALL DEMOLITION AS REQUIRED FOR INSTALLATION OF NEW WORK. 9. COORDINATE INSTALLATION OF ELECTRICAL WORK ABOVE THE CEILING TO PROVIDE THE GREATEST POSSIBLE CLEARANCE FOR INSTALLATION OF PLUMBING AND MECHANICAL INSTALLATION. CONDUIT RUNS TO BE RUN THROUGH TRUSSES WHERE POSSIBLE. 10. COORDINATE EXACT LOCATION OF DEVICES SERVING CASEWORK WITH CASEWORK CONTRACTOR. 11. COORDINATE ALL LOW VOLTAGE CONDUIT AND ROUGH -IN REQUIREMENTS WITH LOW VOLTAGE CONTRACTORS. 12. SWITCHBOARDS, PANELBOARD, DISCONNECT SWITCHES, TRANSFORMER AND CONTACTORS SHALL BE LISTED AND IDENTIFIED AS RATED FOR A MINIMUM OF 75'C CONDUCTOR TERMINATIONS. 13. INCLUDE EQUIPMENT GROUND CONDUCTOR IN ALL RACEWAYS. SIZE RACEWAYS AS NECESSARY TO COMPLY WITH NEC. 14. PROVIDE ALL EMPTY CONDUITS WITH A PULL STRING. 15. PROVIDE #10 AWG CONDUCTORS FOR ALL 20A BRANCH CIRCUITS BETWEEN 100' AND 150' IN LENGTH. PROVIDE #8 AWG CONDUCTORS FOR ALL 20A BRANCH CIRCUITS OVER 150'. 16. PROVIDE #12 AWG CONDUCTORS, #12G, IN 3/4" CONDUIT FOR ALL 20A BRANCH CIRCUITS UNLESS NOTED OTHERWISE. 17. CIRCUITING INDICATED ON PLAN IS PARTIALLY DIAGRAMMATIC FOR CLARITY. CIRCUITING SHALL BE "THRU- WIRING" WHERE /WHEN POSSIBLE. MULTI - CONNECTIONS TO A SINGLE LIGHT FIXTURE FOR FIELD CONDITIONS OR VOLTAGE DROP FACTORS MAY BE REQUIRED (FIXTURES SHALL BE MANUFACTURED TO ACCOMMODATE "THRU- WIRING "), AND RELATED COSTS SHALL BE INCLUDED IN BID. 18. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT QUANTITY AND LOCATION OF LIGHT FIXTURES. poi -o71 19. EMERGENCY LIGHTS SHALL BE INSTALLED AND CIRCUITED PER NEC AND ALL LOCAL CODES. ALL EMERGENCY FIXTURES SHALL BE DUAL VOLTAGE (120/277 AUTO XFMR) BATTERY BACK -UP UNITS. INSTALL CENTRAL BATTERY BACK-UP ONLY IF INDIVIDUAL UNITS ARE PROHIBITED BY LOCAL CODES. CLOSELY COORDINATE WITH TENANT CONSTRUCTION MANAGER. 20. MAKE ALL FINAL ELECTRICAL CONNECTIONS AS REQUIRED FOR A COMPLETE AND OPERATING SYSTEM. 21. WHERE DRYWALL CEILINGS ARE USED, ELECTRICAL CONTRACTOR SHALL ARRANGE CIRCUITING SO THAT JUNCTION BOXES /ACCESS PANELS ARE NOT REQUIRED IN THESE DRYWALL CEILING AREAS. (THE USE OF JUNCTION BOXES IN THESE DRYWALL CEILINGS IS NOT PERMITTED, ARRANGE CIRCUITS TO AVOID THIS SITUATION). FIELD COORDINATE WITH TENANT'S CONSTRUCTION MANAGER PRIOR TO ROUGH -IN TO AVOID CONFLICTS. JUNCTION BOXES MAY BE PLACED ABOVE LAY -IN CEILINGS. 22. FIELD VERIFY EXACT LOCATION AND ELECTRICAL REQUIREMENTS OF ALL HVAC EQUIPMENT WITH MECHANICAL CONTRACTOR PRIOR TO ORDERING RELATED ELECTRICAL EQUIPMENT. 23. PLACEMENT OF ALL RECEPTACLES SHALL BE INTENTIONAL (I.E. CENTERED ON COLUMNS OR WALL FEATURES OR TIGHT TO CORNER). IF RECEPTACLE IS NOT SHOWN IN A DESIRABLE LOCATION, FIELD VERIFY PLACEMENT OF RECEPTACLE WITH TENANT'S CONSTRUCTION MANAGER PRIOR TO RECEPTACLE BOX ROUGH -IN. 24. INSTALLATION OF LIGHTING FIXTURES SHALL BE ACCORDING TO MANUFACTURER'S RECOMMENDATIONS AND ACCORDING TO CODE REQUIREMENTS. 25. ALL LIGHT FIXTURES SCHEDULED MAY NOT NECESSARILY BE USED ON THIS PROJECT. REFER TO ELECTRICAL LIGHTING PLAN. 26. PROVIDE ALL NECESSARY COMPONENTS TO MAKE A COMPLETE WORKING SYSTEM. VERIFY ROW LENGTHS, FEED POINT AND MOUNTING REQUIREMENTS PRIOR TO ORDERING. 27. TAKE ADEQUATE CARE TO CORRECTLY LOCATE ALL ELECTRICAL STUBOUTS, FLOOR BOXES, JUNCTION BOXES, TRACK, ETC. PRECISE LOCATIONS OF FLOOR OUTLETS AND JUNCTION BOXES IS VERY IMPORTANT. 28. ALL CAT -5e WIRE TO BE PROVIDED BY OWNER'S VENDOR. RECEW`YE FEB - 8 2008 PERMIT CENTEE HENDERSON ENGINEERS =_ 10370 RICHMOND AVENUE, SUITE 370 HOUSTON, TX 77042 TEL 713 7837707 FAX 713 783 7797 www.hei- eeg.eem 0750001294 RJS 1MH SIM 12/08/08 ®■ 0 •H laa V 98% OWNER REVIEW HEALTH DEPT RVSNS ISSUED FOR PERMIT ISSUED / REVISED DATE HEALTH DEPT SUBMITTAL 12.17.07 SCHEDULES AND LEGENDS E -1.0 01.03.08 01.11.08 01.25.08 2 3 4 5 6 7 8 9 1 REMOTE STOCK ROOM ELECTRICAL LIGHTING PLAN SCALE: 1/4" =1' -O" PNLBD L PNLBD H 0 0 0 0 0 0 0 ( (b) (c) (d) (e) 0 0 0 L -9 L -3 L -16 L -7 L--15 TO SWITCH "e" 11 (PART) TO SWITCH "m' (f) (g) (h) (i) 0 0 0 0 0 0 0 0 L -1 L -15 L-5 L -7 3 ` SWITCH BANK DETAIL l NOT TO SCALE FC RESTROOM TO SWITCH "g" B CEH TO SWITCH "c" B2A TO SWITCH "I" TO SWITCH "k" TO SWITCH "a" TO SWITCH "d" L L CEH O 0 B2 TO SWITCH "h" i B2 SA 32 SALES AREA 101 B2 B2 L TO SWITCH "j" PA TO SW CH "b" L CEH 82 15 L L 17 ALL EXISTING EXTERIOR EGRESS LIGHTING IS BY LANDLORD. 0) (k) (I) (m) 0 0 0 0 0 0 0 0 L -12 L -16 L -16 L-6 -■"/ ELECTRICAL LIGHTING PLAN SCALE: 1 /4 " =1' -0" L 1 TO SWITCH "f" L 38 11 L (PART) ALL EXISTING EXTERIOR EGRESS LIGHTING IS BY LANDLORD. Doo1 • ELECTRICAL PLAN NOTES: El 6 8 9 m MASTER SWITCH BANK. REFER TO DETAIL 3 ON THIS SHEET FOR MORE INFORMATION. LIGHT FIXTURES INSTALLED IN ISLAND BY FIXTURE CONTRACTOR AND CONNECTED TO JUNCTION BOX IN FIXTURE. ROUTE CONDUIT UNDERGROUND FROM ISLAND TO WALL AS SHOWN. GROUP CONDUIT WITH OTHER UNDERGROUND CONDUITS SHOWN ON SHEET E -2.1. 111 RECEPTACLES FOR SLAB SHELVE UGHT FIXTURES. INSTALL UGHT FIXTURES FOR SHELVES SUPPLIED WITH SLAB SHELVES AND MAKE FINAL CONNECTIONS. SWITCH SHELVES AND SIGNS SEPARATELY. COORDINATE RECEPTACLES WITH FIXTURE DRAWINGS. IT 1 CONNECTION POINT FOR LIGHT FIXTURE INSTALLED IN CORE CABINET BY FIXTURE CONTRACTOR. COORDINATE ELECTRICAL CONNECTION WITH FIXTURE DRAWINGS. M CIRCUIT EMERGENCY LIGHTING FIXTURES AHEAD OF ANY SWITCHING. INTERNALLY ILLUMINATED SIGN BOX FURNISHED BY TENANT. CIRCUIT VIA TIMESWITCH. SET TIMESWITCH TO MALL'S OPERATING HOURS. LIGHT FIXTURES INSTALLED IN STOREFRONT DIPPER BY FIXTURE CONTRACTOR. MAKE ALL ELECTRICAL CONNECTIONS AS REQUIRED. CUT FLOOR TO FIXTURE AND PROVIDE (2) DUPLEX OUTLETS IN FLUSH FLOOR BOX WITH BRASS COVER. CONNECT ONE RECEPTACLE TO SWTICHED CIRCUIT L -7 AND LABEL RECEPTACLE "LIGHTING." CONNECT OTHER RECEPTACLE TO CIRCUIT INDICATED ON E -2.1. COORDINATE FLOOR BOX LOCATION WITH FIXTURE DRAWINGS. PATCH FLOOR TO MATCH EXISTING. SHOW WINDOW RECEPTACLE. COLOR OF RECEPTACLE AND COVER PLATE SHALL MATCH CEILING COLOR. NEW SUSPENDED 45KVA TRANSFORMER ABOVE CEILING. REFER TO DETAIL 3, SHEET E -2.1 FOR FURTHER INFORMATION. 1 0 EXISTING REMOTE STORAGE ROOM. NO ELECTRICAL WORK TO BE PERFORMED TO EXISTING SPACE. LOCATION OF CONTACTORS "C1 " AND "C2 ", AND TIMESWITCH "TS1 ". REFER TO SHEET E -4.0 FOR CONTACTOR SCHEDULE. 12 LIGHT FIXTURE LOCATED ABOVE FINISHED RESTROOM, FOR STORAGE ILLUMINATION. RECEIVE FEB - 8 2006 PERMIT CENTER 1HENDERSON ENGINEERS= 10370 RICHMOND AVENUE, SURE 370 HOUSTON, TX 77042 TEL 713 783 7707 Fax 713 783 7797 www.hei•eng.com 0750001294 R151MH S1M Aitte 1 ec t ; eg W O Imm Z I— la Q W 0 $X:12 /08 /08 CI 1 O co 07 co N C C 0 C1) ISSUED / REVISED DATE HEALTH DEPT SUBMITTAL 98% OWNER REVIEW HEALTH DEPT RVSNS ISSUED FOR PERMIT ELECTRICAL LIGHTING PLAN E -2.0 12.17.07 01.03.08 01.11.08 01.25.08 MODA4 PROJECT NUMBER: 07009 555 Southcenter DIPPING UNIT/STOREFRONT LTG BULK CASE/REGISTER LTG CUSTOM AND CORE LIGHTS STOREFRONT LIGHTBOXES SALES AREA DOWN LTG NESTING TABLE LTG NESTING TABLE LTG BAR DISPLAY LTG BACK BAR LIGHTS CORE CABINETS CORE CABINETS SLAB SHELVES SALES AREA ACCENT LTG :,- t ' 0 2 [.L3 II- --�0 f O 1 ME t REMOTE STOCK ROOM IO2 EX STING PNLBD 2 3 4 5 6 7 8 9 1 REMOTE STOCK ROOM ELECTRICAL LIGHTING PLAN SCALE: 1/4" =1' -O" PNLBD L PNLBD H 0 0 0 0 0 0 0 ( (b) (c) (d) (e) 0 0 0 L -9 L -3 L -16 L -7 L--15 TO SWITCH "e" 11 (PART) TO SWITCH "m' (f) (g) (h) (i) 0 0 0 0 0 0 0 0 L -1 L -15 L-5 L -7 3 ` SWITCH BANK DETAIL l NOT TO SCALE FC RESTROOM TO SWITCH "g" B CEH TO SWITCH "c" B2A TO SWITCH "I" TO SWITCH "k" TO SWITCH "a" TO SWITCH "d" L L CEH O 0 B2 TO SWITCH "h" i B2 SA 32 SALES AREA 101 B2 B2 L TO SWITCH "j" PA TO SW CH "b" L CEH 82 15 L L 17 ALL EXISTING EXTERIOR EGRESS LIGHTING IS BY LANDLORD. 0) (k) (I) (m) 0 0 0 0 0 0 0 0 L -12 L -16 L -16 L-6 -■"/ ELECTRICAL LIGHTING PLAN SCALE: 1 /4 " =1' -0" L 1 TO SWITCH "f" L 38 11 L (PART) ALL EXISTING EXTERIOR EGRESS LIGHTING IS BY LANDLORD. Doo1 • ELECTRICAL PLAN NOTES: El 6 8 9 m MASTER SWITCH BANK. REFER TO DETAIL 3 ON THIS SHEET FOR MORE INFORMATION. LIGHT FIXTURES INSTALLED IN ISLAND BY FIXTURE CONTRACTOR AND CONNECTED TO JUNCTION BOX IN FIXTURE. ROUTE CONDUIT UNDERGROUND FROM ISLAND TO WALL AS SHOWN. GROUP CONDUIT WITH OTHER UNDERGROUND CONDUITS SHOWN ON SHEET E -2.1. 111 RECEPTACLES FOR SLAB SHELVE UGHT FIXTURES. INSTALL UGHT FIXTURES FOR SHELVES SUPPLIED WITH SLAB SHELVES AND MAKE FINAL CONNECTIONS. SWITCH SHELVES AND SIGNS SEPARATELY. COORDINATE RECEPTACLES WITH FIXTURE DRAWINGS. IT 1 CONNECTION POINT FOR LIGHT FIXTURE INSTALLED IN CORE CABINET BY FIXTURE CONTRACTOR. COORDINATE ELECTRICAL CONNECTION WITH FIXTURE DRAWINGS. M CIRCUIT EMERGENCY LIGHTING FIXTURES AHEAD OF ANY SWITCHING. INTERNALLY ILLUMINATED SIGN BOX FURNISHED BY TENANT. CIRCUIT VIA TIMESWITCH. SET TIMESWITCH TO MALL'S OPERATING HOURS. LIGHT FIXTURES INSTALLED IN STOREFRONT DIPPER BY FIXTURE CONTRACTOR. MAKE ALL ELECTRICAL CONNECTIONS AS REQUIRED. CUT FLOOR TO FIXTURE AND PROVIDE (2) DUPLEX OUTLETS IN FLUSH FLOOR BOX WITH BRASS COVER. CONNECT ONE RECEPTACLE TO SWTICHED CIRCUIT L -7 AND LABEL RECEPTACLE "LIGHTING." CONNECT OTHER RECEPTACLE TO CIRCUIT INDICATED ON E -2.1. COORDINATE FLOOR BOX LOCATION WITH FIXTURE DRAWINGS. PATCH FLOOR TO MATCH EXISTING. SHOW WINDOW RECEPTACLE. COLOR OF RECEPTACLE AND COVER PLATE SHALL MATCH CEILING COLOR. NEW SUSPENDED 45KVA TRANSFORMER ABOVE CEILING. REFER TO DETAIL 3, SHEET E -2.1 FOR FURTHER INFORMATION. 1 0 EXISTING REMOTE STORAGE ROOM. NO ELECTRICAL WORK TO BE PERFORMED TO EXISTING SPACE. LOCATION OF CONTACTORS "C1 " AND "C2 ", AND TIMESWITCH "TS1 ". REFER TO SHEET E -4.0 FOR CONTACTOR SCHEDULE. 12 LIGHT FIXTURE LOCATED ABOVE FINISHED RESTROOM, FOR STORAGE ILLUMINATION. RECEIVE FEB - 8 2006 PERMIT CENTER 1HENDERSON ENGINEERS= 10370 RICHMOND AVENUE, SURE 370 HOUSTON, TX 77042 TEL 713 783 7707 Fax 713 783 7797 www.hei•eng.com 0750001294 R151MH S1M Aitte 1 ec t ; eg W O Imm Z I— la Q W 0 $X:12 /08 /08 CI 1 O co 07 co N C C 0 C1) ISSUED / REVISED DATE HEALTH DEPT SUBMITTAL 98% OWNER REVIEW HEALTH DEPT RVSNS ISSUED FOR PERMIT ELECTRICAL LIGHTING PLAN E -2.0 12.17.07 01.03.08 01.11.08 01.25.08 MODA4 PROJECT NUMBER: 07009 555 Southcenter DIPPING UNIT/STOREFRONT LTG BULK CASE/REGISTER LTG CUSTOM AND CORE LIGHTS STOREFRONT LIGHTBOXES SALES AREA DOWN LTG NESTING TABLE LTG NESTING TABLE LTG BAR DISPLAY LTG BACK BAR LIGHTS CORE CABINETS CORE CABINETS SLAB SHELVES SALES AREA ACCENT LTG :,- t 2 8 II- --�0 f O 2 3 4 5 6 7 8 9 1 REMOTE STOCK ROOM ELECTRICAL LIGHTING PLAN SCALE: 1/4" =1' -O" PNLBD L PNLBD H 0 0 0 0 0 0 0 ( (b) (c) (d) (e) 0 0 0 L -9 L -3 L -16 L -7 L--15 TO SWITCH "e" 11 (PART) TO SWITCH "m' (f) (g) (h) (i) 0 0 0 0 0 0 0 0 L -1 L -15 L-5 L -7 3 ` SWITCH BANK DETAIL l NOT TO SCALE FC RESTROOM TO SWITCH "g" B CEH TO SWITCH "c" B2A TO SWITCH "I" TO SWITCH "k" TO SWITCH "a" TO SWITCH "d" L L CEH O 0 B2 TO SWITCH "h" i B2 SA 32 SALES AREA 101 B2 B2 L TO SWITCH "j" PA TO SW CH "b" L CEH 82 15 L L 17 ALL EXISTING EXTERIOR EGRESS LIGHTING IS BY LANDLORD. 0) (k) (I) (m) 0 0 0 0 0 0 0 0 L -12 L -16 L -16 L-6 -■"/ ELECTRICAL LIGHTING PLAN SCALE: 1 /4 " =1' -0" L 1 TO SWITCH "f" L 38 11 L (PART) ALL EXISTING EXTERIOR EGRESS LIGHTING IS BY LANDLORD. Doo1 • ELECTRICAL PLAN NOTES: El 6 8 9 m MASTER SWITCH BANK. REFER TO DETAIL 3 ON THIS SHEET FOR MORE INFORMATION. LIGHT FIXTURES INSTALLED IN ISLAND BY FIXTURE CONTRACTOR AND CONNECTED TO JUNCTION BOX IN FIXTURE. ROUTE CONDUIT UNDERGROUND FROM ISLAND TO WALL AS SHOWN. GROUP CONDUIT WITH OTHER UNDERGROUND CONDUITS SHOWN ON SHEET E -2.1. 111 RECEPTACLES FOR SLAB SHELVE UGHT FIXTURES. INSTALL UGHT FIXTURES FOR SHELVES SUPPLIED WITH SLAB SHELVES AND MAKE FINAL CONNECTIONS. SWITCH SHELVES AND SIGNS SEPARATELY. COORDINATE RECEPTACLES WITH FIXTURE DRAWINGS. IT 1 CONNECTION POINT FOR LIGHT FIXTURE INSTALLED IN CORE CABINET BY FIXTURE CONTRACTOR. COORDINATE ELECTRICAL CONNECTION WITH FIXTURE DRAWINGS. M CIRCUIT EMERGENCY LIGHTING FIXTURES AHEAD OF ANY SWITCHING. INTERNALLY ILLUMINATED SIGN BOX FURNISHED BY TENANT. CIRCUIT VIA TIMESWITCH. SET TIMESWITCH TO MALL'S OPERATING HOURS. LIGHT FIXTURES INSTALLED IN STOREFRONT DIPPER BY FIXTURE CONTRACTOR. MAKE ALL ELECTRICAL CONNECTIONS AS REQUIRED. CUT FLOOR TO FIXTURE AND PROVIDE (2) DUPLEX OUTLETS IN FLUSH FLOOR BOX WITH BRASS COVER. CONNECT ONE RECEPTACLE TO SWTICHED CIRCUIT L -7 AND LABEL RECEPTACLE "LIGHTING." CONNECT OTHER RECEPTACLE TO CIRCUIT INDICATED ON E -2.1. COORDINATE FLOOR BOX LOCATION WITH FIXTURE DRAWINGS. PATCH FLOOR TO MATCH EXISTING. SHOW WINDOW RECEPTACLE. COLOR OF RECEPTACLE AND COVER PLATE SHALL MATCH CEILING COLOR. NEW SUSPENDED 45KVA TRANSFORMER ABOVE CEILING. REFER TO DETAIL 3, SHEET E -2.1 FOR FURTHER INFORMATION. 1 0 EXISTING REMOTE STORAGE ROOM. NO ELECTRICAL WORK TO BE PERFORMED TO EXISTING SPACE. LOCATION OF CONTACTORS "C1 " AND "C2 ", AND TIMESWITCH "TS1 ". REFER TO SHEET E -4.0 FOR CONTACTOR SCHEDULE. 12 LIGHT FIXTURE LOCATED ABOVE FINISHED RESTROOM, FOR STORAGE ILLUMINATION. RECEIVE FEB - 8 2006 PERMIT CENTER 1HENDERSON ENGINEERS= 10370 RICHMOND AVENUE, SURE 370 HOUSTON, TX 77042 TEL 713 783 7707 Fax 713 783 7797 www.hei•eng.com 0750001294 R151MH S1M Aitte 1 ec t ; eg W O Imm Z I— la Q W 0 $X:12 /08 /08 CI 1 O co 07 co N C C 0 C1) ISSUED / REVISED DATE HEALTH DEPT SUBMITTAL 98% OWNER REVIEW HEALTH DEPT RVSNS ISSUED FOR PERMIT ELECTRICAL LIGHTING PLAN E -2.0 12.17.07 01.03.08 01.11.08 01.25.08 MODA4 PROJECT NUMBER: 07009 555 Southcenter DIPPING UNIT/STOREFRONT LTG BULK CASE/REGISTER LTG CUSTOM AND CORE LIGHTS STOREFRONT LIGHTBOXES SALES AREA DOWN LTG NESTING TABLE LTG NESTING TABLE LTG BAR DISPLAY LTG BACK BAR LIGHTS CORE CABINETS CORE CABINETS SLAB SHELVES SALES AREA ACCENT LTG FIRE PROTECT. SYMBOLS I NOTE: THIS IS A NECESSARILY MA STER USED LEGEND ON THE AND NOT DRAWINGS. ALL SYMBOLS, ETC. ARE FIRE ALARM © F FIRE ALARM CONTROL PANEL /UNIT FACP RECESSED FIRE ALARM CONTROL PANEL /UNIT FAAP FIRE ALARM ANNUNCIATOR PANEL FAAP RECESSED FIRE ALARM ANNUNCIATOR PANEL © FACT FIRE ALARM TRANSPONDER A� AMPUFIER PANEL RPS REMOTE POWER SUPPLY RT REMOTE TEST STATION WITH INDICATING LIGHT RL REMOTE INDICATING LIGHT PS PRESSURE SWITCH LOW /HIGH FS WATERFLOW ALARM SWITCH 'Jr CONTROL VALVE TAMPER SWITCH DH MAGNETIC DOOR HOLD OPEN DEVICE K KNOX BOX • PULL STATION FIREFIGHTER'S PHONE JACK O HEAT DETECTOR (E INDICATES ELEVATOR RECALL) SMOKE DETECTOR (E INDICATES ELEVATOR RECALL) SINGLE STATION SMOKE DETECTOR I)) »)) BEAM DETECTOR 0 RD ? 0:1 g IAN al Q x1 D-) D DUCT MOUNTED SMOKE DETECTOR (SD= SUPPLY /RD= RETURN) AREA OF REFUGE 2 -WAY COMMUNICATION SYSTEM WALL MOUNTED AUDIBLE NOTIFICATION APPLIANCE WALL MOUNTED VISIBLE NOTIFICATION APPLIANCE ## ## INDICATES CANDELA WALL MOUNTED AUDIBLE /VISIBLE NOTIFICATION APPLIANCE, ## ## INDICATES CANDELA CEILING MOUNTED AUDIBLE NOTIFICATION APPLIANCE CEILING MOUNTED VISIBLE NOTIFICATION APPLIANCE, ## ## INDICATES CANDELA CEILING MOUNTED AUDIBLE /VISIBLE NOTIFICATION APPLIANCE, ## ## INDICATES CANDELA ABORT SWTICH BELL ANNOTATION 01 FIRE PROTECTION PLAN CALLOUT S CONNECTION POINT OF NEW WORK TO EXISTING Q DETAIL REFERENCE UPPER NUMBER INDICATES DETAIL NUMBER Mr LOWER NUMBER INDICATES SHEET NUMBER Q SECTION CUT DESIGNATION ler ABBREVIATIONS AFF ABOVE FINISHED FLOOR AFC ABOVE FINISHED GRADE CD CANDELA DI DUCTILE IRON ESFR EARLY SUPPRESSION FAST RESPONSE OR EXISTING TO REMAIN FHC FIRE HOSE CABINET FP FIRE PROTECTION GC GENERAL CONTRACTOR GPM GALLONS PER MINUTE JB JUNCTION BOX MAX MAXIMUM MIN MINIMUM N/A NOT APPLICABLE NIC NOT IN CONTRACT OC ON CENTER PIV POST INDICATOR VALVE PROVIDE FURNISH AND INSTALL PRV PRESSURE REDUCING VALVE RD RETURN DUCT REV REVISION SD SUPPLY DUCT SF SQUARE FEET TYP TYPICAL UL UNDERWRITERS LABORATORIES, INC. UNO UNLESS NOTED OTHERWISE V VOLT(S) WP WEATHERPROOF 1 2 3 4 5 6 7 8 9 10 REMOTE STOCK ROOM 104 / SMITING PNLBD REMOTE STOCK ROOM ELECTRICAL POWER PLAN SCALE: 1 /4" =1' -0" 31 30/2/15/3R 30/3/20/3R L 29 RESTROOM 102 3 ELECTRICAL POWER PLAN SCALE: 1 /4 " =1' --0" FIRE ALARM GENERAL NOTES: 1. FIRE ALARM SYSTEM DESIGN, INSTALLATION AND MATERIALS SHALL BE IN ACCORDANCE WITH NFPA 70 AND NFPA 72. SYSTEM SHALL ALSO MEET ALL APPLICABLE BUILDING CODES, FIRE CODES AND THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION AND INSURANCE CARRIER. VERIFY REQUIREMENTS PRIOR TO BID SUBMITTAL. 2. INFORMATION ON CONTRACT DOCUMENTS IS GENERAL INFORMATION AND FOR BID PURPOSES ONLY. LAYOUT SYSTEM, PERFORM REQUIRED CALCULATIONS AND COORDINATE WITH OTHER TRADES. 3. PROVIDE ADDITIONAL MATERIALS AND LABOR REQUIRED DUE TO LACK OF COORDINATION OR TO MEET AUTHORITY HAVING JURISDICTION AND INSURANCE CARRIER REQUIREMENTS AT NO ADDITIONAL COST TO THE OWNER. 4. PROVIDE ALL EQUIPMENT AND LABOR REQUIRED FOR A COMPLETE AND OPERATIONAL FIRE ALARM SYSTEM. 5. THE FIRE ALARM CONTROL PANEL (FACP) SHOWN SHALL BE COORDINATED WITH THE FIRE DEPARTMENT AND AHJ PRIOR TO INSTALLATION. 6. PROVIDE AUDIBLE AND VISIBLE NOTIFICATION APPLIANCES AS INDICATED ON THE DRAWINGS. 7. PROVIDE DUCT DETECTION AND SHUTDOWN FOR AIR DISTRIBUTION SYSTEMS EXCEEDING 2000 CFM. DUCT SMOKE DETECTION SHALL TRANSMIT A SUPERVISORY SIGNAL TO THE FACP. 8. FORWARD COMPLETED FIRE ALARM CERTIFICATE OF COMPLETION TO THE OWNER. 9. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION. FIRE ALARM PLAN NOTES: 0 PROVIDE DUCT MOUNTED SMOKE DETECTOR FOR AIR HANDLING UNIT SHUT -DOWN. INSTALL DETECTOR PER MANUFACTURER'S RECOMMENDATIONS. REFER TO MECHANICAL SHEETS FOR AIR HANDLING UNIT AND DUCTWORK LAYOUT AND DETAILS. O2 PROVIDE LOW VOLTAGE WIRING FROM DUCT DETECTOR TO REMOTE TEST STATION. MOUNT REMOTE TEST STATION AT 48" AFF. CONNECT FIRE SPRINKLER MONITORING DEVICES TO FIRE ALARM SYSTEM. COORDINATE QUANTITY AND LOCATION OF DEVICES WITH FIRE PROTECTION SYSTEMS. SUPPORT SYSTEM SHALL BE DESIGNED BY A LICENSED STRUCTURAL ENGINEER INSTALL TRANSFORMER ABOVE AND IN FRONT OF ELECTRICAL PANELBOARD MINIMUM DISTANCE 1' -0" PANELBOARD WORKING SPACE CLEARANCE AS REQUIRED BY NEC SUSPENDED TRANSFORMER @ MOUNTING LOCATION DETAIL NO TO SCALE ELECTRICAL GENERAL NOTES: 1. 2. PROVIDE PULL THRU CONDUIT BETWEEN CASH REGISTER COUNTERS FOR CASH REGISTER INSTALLATION COMPANY. 3. VERIFY ALL NEW WORK REQUIRED BY THE LANDLORD. 4. ALL WORK OUTSIDE OF THE TENANT SPACE SHALL BE BY A LANDLORD APPROVED CONTRACTOR. 5. PROVIDE ACCESS TO ANY LANDLORD EQUIPMENT, VALVES, DAMPERS, CLEANOUTS, JUNCTION BOXES, ETC. LOCATED ABOVE GYPSUM BOARD CEILING AREAS. VERIFY WITH LANDLORD PRIOR TO START OF WORK. 6. ALL REQUIRED INTERIOR PHONE CONDUIT WITH PULL STRING SHALL BE SUPPLIED BY THE GENERAL CONTRACTOR FROM CASH REGISTER TO DEMARK. 7. DO NOT ATTACH OR SUPPORT ANY ELECTRICAL CONDUITS FROM THE ROOF DECK. HANGERS, CLAMPS, AND SUPPORTS SHALL BE FASTENED TO BAR JOISTS OR BEAMS ONLY. ELECTRICAL PLAN NOTES: 1 2 3 141 5 6 n 9 11 12 13 MAKE ALL CONNECTIONS BETWEEN LOW - VOLTAGE DATA COMMUNICATIONS WIRING AND CASH REGISTER. RECEIVE[ FEB -8 2005 PERMIT CENTEI DEDICATED ELECTRICAL SPACE. EXTENDS TO 6' ABOVE PANEL BOARD OR TO STRUCTURAL CEILING, WHICHEVER IS LOWER. LOCATE TRANSFORMER 6" MINIMUM FROM ALL WALLS. MAXIMUM OF 10' SECONDARY CONDUCTOR LENGTH. FLEXIBLE CONDUIT RIGID CONDUIT ELECTRICAL PANELBOARD SUPPLIED BY TRANSFORMER COORDINATE LOCATION OF RECEPTACLES ALONG BACK COUNTER WITH FIXTURE DRAWINGS. REFER TO ARCHITECTURAL DRAWINGS FOR MORE INFORMATION. DEDICATED ELECTRICAL SPACE (BOTTOM OF PANELBOARD TO FLOOR) FLOOR CONNECTION FOR COOLED SHOWCASE. PROVIDE CIRCUITING AS SHOWN IN SLAB IN 3/4 "C. COORDINATE SAW CUTTING OF SLAB WITH ARCHITECT AND OWNER. RECEPTACLE AND DATA OUTLET FOR P05 STATION WITHIN MILLWORK. COORDINATE EXACT LOCATION WITH ARCHITECT/ OWNER PRIOR TO ROUGH -IN. RECEPTACLES FURNISHED BY FIXTURE SUPPLIER. CIRCUIT AS SHOWN. REFER TO ARCHITECTURAL DRAWINGS FOR MORE INFORMATION. PROVIDE DUPLEX RECEPTACLE FOR MUSIC SYSTEM. VERIFY EXACT LOCATION WITH ARCHITECT /OWNER PRIOR TO ROUGH-IN. CUT FLOOR TO STOREFRONT DIPPER AND PROVIDE (2) DUPLEX RECEPTACLES IN FLUSH FLOOR BOX WITH BRASS COVER. CONNECT ONE RECEPTACLE TO SWITCHED CIRCUIT AND LABEL RECEPTACLE "POWER ". CONNECT OTHER RECEPTACLE TO CIRCUIT INDICATED ON E --2.0. COORDINATE FLOOR BOX LOCATION WITH FIXTURE DRAWINGS. PATCH FLOOR TO MATCH EXISTING. PROVIDE (2) 1 " CONDUITS WITH PULL WIRE UNDER SLAB AS SHOWN TO BACK WALL. ROUTE DATA CONDUITS OVERHEAD BACK TO STOCK ROOM. NEW " VENTROL" REFRIGERATION AND CONDENSING UNITS PROVIDED BY GODIVA. VENTROL CONDENSING UNIT LOCATED ON ROOF. LOCATION TO BE DETERMINED. COORDINATE FINAL LOCATION OF CONDENSING UNIT WITH LANLORD PRIOR TO INSTALLATION. 10 NEW SUSPENDED 45KVA TRANSFORMER ABOVE CEIUNG. REFER TO DETAIL 3, THIS SHEET, FOR FURTHER INFORMATION. EXISTING REMOTE STOCK ROOM. NO ELECTRICAL WORK TO BE � PERFORMED TO EXISTING SPACE. . PROVIDE EDWARDS SIGNALING AND SECURITY SYSTEM PULL COR ° #6537 IN HANDICAPPED RESTROOM FOR STAND -ALONE CALL-FOR' ,a. V AID SYSTEM. PROVIDE POWER THROUGH CIRCUIT L -27. • PROVIDE EDWARDS SIGNALING AND SECURITY SYSTEM HORN/ STROBE #6536 -G5 IN HANDICAPPED RESTROOM FOR STAND -ALONE CALL - FOR -AID SYSTEM. HENDERSON ENGINEERS_ 10370 RICHMOND AVENUE, SUITE 370 HOUSTON, TX 77042 TEL 713 783 7707 FAX 713 783 7797 www.hei- eeg.com 0750001294 R1S 1MH SI M ISSUED / REVISED 12/08/08 Ifte C:) V HEALTH DEPT SUBMITTAL 98% OWNER REVIEW HEALTH DEPT RVSNS ISSUED FOR PERMIT ELECTRICAL POWER PLAN E -2.1 DATE 12.17.07 01.03.08 01.11.08 01.25.08 PANELBOARD: L (NEW) FAULT CURRENT: SEE RISER DIAGRAM EQUIPMENT GROUND BUS BUS AMPS: 225A AIC RATING:10,000 FULLY RATED MAIN SIZE /TYPE: 150A MCB SERVES: GODIVA CHOCOLATIER VOLTS /PHASE: 208Y/120V, 3PH, 4W MOUNTING: SURFACE SECTION: 1 LOCATION: STOCK ROOM CKT I NO. DESCRIPTION VOLTAMP PHASE N AMP P P AMP N IRRE VOLTAMP PHASE DESCRIPTION NO. I A C A B C C 1 LTG -- BAR DISPLAY LTG 1,040 ' ' 12 20 1 2 15 12 587 '/ '/ PWR - FCU -1 2 3 LTG - COUNTER TOPS WIND r1O1j/,I 175 r/JJJJJ 12 20 1 4 %j / 587 j 5 LTG - BACK BAR LTG f / / / J/�r,/ / /J/ /,/� 240 12 20 1 1 20 12 r/ffff f/Jr/fj Qf 11E111 1,200 LTG - WINDOW SIGNAGE 6 7 LTG - GENERAL LTG + EM 286 i , 12 20 1 1 20 SPARE / / i SPARE 8 9 LTG - SALES ACCENT LTG % / / /// 160 ' / / / / // 12 20 1 1 20 12 %, / /// 696 / / / / //i PWR - VAV -1 10 11 RCPT - SHOW WINDOW /� /� 540 12 20 1 1 20 12 / / / / ///, % / / //i 193 LTG - COUN I LRTOPS 12 13 LTG - STOCK /RESTROOM 450 ' / / / /// % / / /// 12 20 1 1 20 12 1,080 %///7/ / / / / /// RCPT - CONV. RCPTS 14 15 LTG - SLAB SHELVES CORE ' 1,040 ' 12 20 1 1 20 12 ' /// 160 ' LTG - CORE CABINETS 16 17 PWR - EXTERIOR SIGNAGE 2 1 / / Jf/� r J/A 1,200 12 20 1 1 20 12 r/jffJJ/�r/ / /ff/ 1,000 PWR - UC REFRIGERATOR 18 19 RCPT - REFRIGERATOR 1,200 % /Jf //Jr%Jj /J 12 20 1 1 20 12 720 %f / //j/,/ 1.25 RCPT - ISLAND REGISTERS 20 21 RCPT - ICE MACHINE MOTORS 1,056 / 12 20 1 1 20 12 6,050 1,500 / PWR - BLENDER 1 22 23 SPARE 49 ' 20 1 1 20 12 ' 1,000 PWR - VENTROL EVAP. UNIT 24 25 SPARE IIII■I■r/JJ /j JAr/J / 20 1 1 20 - p'JJjj/$%Jff/ SPARE 26 27 PWR - CALL FOR AID SYSTEM ® 360 r/JJQJ 12 20 1 1 20 r/jJ /j,%J SPARE 28 29 PWR -- VENTROL COND. UNEF r/J /jjAr//f 988 /,/,� 988 12 15 2 3 50 8 F/ / / /Ar//jf /j 2 880 PWR -- WATER HEATER EQ -27A 30 32 31 p�JfJJ/�r/fJJ /J 4,992 r%J /f J'/j 2,880 /j //// / 33 PWR - HEAT GUN / 500 / 12 20 1 34 35 PWR - SHRINK WRAP ' / / /// /// i 500 12 20 1 1 20 12 ' / //, // y 800 RCPT - HOT POT 36 37 PWR - TS /CONTACTORS 250 / 7 / /// 12 20 1 1 20 12 1,200 / / /// / / / //f PWR - EXTERIOR SIGNAGE 1 38 39 PWR - COOLED SHOWCASE / /////// 1 / // �/ 12 20 1 1 20 12 / / /// / 1,500 / / / /// PWR - BLENDER 2 40 41 PWR - COOLED SHOWCASE LTG //////// ////////, 150 12 20 1 1 20 12 / /// i' / / / / //i 1,000 PWR - COUNTER REFRIG 42 SUBTOTAL 4.214 4,291 3,618 8,579 7.323 8,073 SUBTOTAL 1 TOTAL PHASE A - VA 12,793 LOAD CONN. VA DE LOAD CONN. VA DF AMPS 107 COOLING 1,976 1.00 REFRIGERATION 3,556 1.00 SIGN /DISPLAY 3,600 1.25 TOTAL PHASE B - VA 11,614 HEATING 478 0 AMPS 97 LIGHTING 2,214 1.25 KITCHEN 1.00 , TOTAL PHASE C - VA 11,691 RECEPTACLES 2,880 1.0/.5 EXISTING 1.00 LARGE MOTOR 696 1.25 TOTAL DEMAND AMPS 97 MOTORS 796 1.00 TOTAL PNLBD - VA 36,098 SUPP HEAT 10,752 1.00 SHOW WINDOW 6,050 1.25 44,270 VA AMPS 100 MISC EQUIP 8,610 1.00 LTG TRACK 1.00 123 A PANELBOARD NOTES LCK - LOCKABLE OFF (FOR MAINTENANCE) C# - VIA LTG CONTACTOR # LO - HANDLE TAB-ON LTG TRACK - TRACK LENGTH EM --- EMERG LTG /LOCKABLE TAB SIGN /DISPLAY - SIGNAGE & DISPLAY CASE PANELBOARD: H (NEW) FAULT CURRENT: SEE RISER DIAGRAM EQUIPMENT GROUND BUS BUS AMPS: 225A AIC RATING:14,000 FULLY RATED MAIN SIZE /TYPE: 200A MCB SERVES: FIRST FLOOR VOLTS /PHASE: 480Y/277V, 3PH, 4W MOUNTING: SURFACE SECTION: 1 LOCATION: ELECTRICAL ROOM, ROOM #:100 I CKT L N0. DESCRIPTION VOLTAMPS PHASE WIRE NO. BKR AMP P P BKR AMP WIRE NO. VOLTAMPS PHASE DESCRIPTION CKT I NO. A B C A B C 1 PWR - CU -1 1,657 6 20 3 3 70 4 ' W / JM WW2 , 11,614 r/,/fff PNLBD L THRU 45KVA XFMR TXL 2 3 Or 1,657 r 4 W © 6 P/'/%'jAr%j /j jA 1,657 r/jjj/ /A 11 691 9 SPARE W - � A 125% 20 1 1 20 7.56 �Q/� r/jVf - a SPARE 11E111 SPARE 11 SPARE 60.18 - 200 20 1 1 20 AMPS r% / /J Q)r%f,/ J J , Q- SPARE OM 14 13 SPARE _{%j/jAr/ / /jjjA 20 1 1 20 - I% /J // V .a SPARE ® SPARE PWI- r%jj /A 20 1 1 20 r%jl�j�- r/JQjfA SPARE UN 17 SPARE '// // / / 20 1 1 20 / i SPARE 18 SUBTOTAL 1,657 1,657 1,657 12,554 11,614 11,691 SUBTOTAL I TOTAL PHASE A - VA 14,211 LOAD CONN. VA DF LOAD CONN. VA DF AMPS 51 COOLING 6,947 1.00 REFRIGERATION 3556 1.00 TOTAL PHASE B - VA 13,271 HEATING 478 0 SIGN /DISPLAY 3,600 1.25 1.00 AMPS 48 UGHTING 2,214 1.25 KITCHEN EXISTING 1.00 TOTAL PHASE C - VA 13,348 RECEPTACLES 2,880 1. /.5 1.00 LARGE MOTOR 1.25 TOTAL DEMAND AMPS 48 MOTORS 1,492 TOTAL PNLBD - VA 40,830 SUPP HEAT 10,752 1.00 SHOW WINDOW 6,050 1.25 49,067 VA MISC EQUIP 8,610 1.00 AMPS 49 LTG TRACK 1.00 59 A PANELBOARD NOTES LCK - LOCKABLE OFF (FOR MAINTENANCE) LTG TRACK - TRACK LENGTH SIGN /DISPLAY --- SIGNAGE & DISPLAY CASE LIGHTING CONTACTOR SCHEDULE CONTACTOR NUMBER SERVICE DESCRIPTION: 480Y/277V, 3PH CONTACTOR CONTROL CIRCUIT LOAD DESCRIPTION AMPS POLES CIRCUIT NO. VOLTS OPERATION BY Cl 30 10 L- 1,5,7,11,12,15,16,17 120 TS ON/TS OFF SALES FLOOR LIGHTING C2 30 6 L- 3,6,9,28 120 TS ON/TS OFF SHOW WINDOW, SIGNAGE CONTACTOR NOTES: 1. PROVIDE MECHANICALLY HELD CONTACTORS. REFER TO SPECIFICATIONS. 2. PROVIDE ALL REQUIRED CONTROL ACCESSORIES NECESSARY FOR OPERATION AS DESCRIBED ABOVE. 3. PROVIDE LABELS FOR EACH CONTACTOR INDICATING THE LOADS CONTROLLED AND CONTROL CIRCUIT NUMBERS. 4. NUMBER ALL CONDUCTORS AT EACH CONTACTOR. 5. PROVIDE EACH CONTACTOR WITH MINIMUM OF (1) SPARE POLES, IN ADDITION TO ACTIVE POLES INDICATED. 6. REFER TO PANELBOARD SCHEDULE FOR CONTROL CIRCUFING INFORMATION. . ABBREVIATIONS; TS = 11MESWITCH TENANT ELECTRICAL SERVICE LOAD SUMMARY BUILDING OCCUPANCY TYPE: M BUILDING SQUARE FOOTAGE: 950 SERVICE DESCRIPTION: 480Y/277V, 3PH 4W I LOAD DESCRIPTION I Connected KVA Demand FACTOR Demand I KVA HVAC - SUMMER 6.95 100% 6.95 HVAC - WINTER 0.48 100% 0.00 LIGHTING (PER NEC -220) 2.85 125% .3.56 RECEPTACLES 2.88 100 %;50% 2.88 MOTOR LOADS 0.80 100% 0.80 LARGEST MOTOR LOAD 0.70 125% 0.87 SUPPLEMENTAL ELECTRIC HEAT 10.75 100% 10.75 MISCELLANEOUS EQUIPMENT 8.61 100% 8.61 REFRIGERATION EQUIPMENT 3.56 100% 3.56 DISPLAY CASE /SIGNAGE 3.60 125% 4.50 SHOW WINDOW / TRACK LIGHTING 6.05 PER NEC 7.56 TOTAL LOAD 4 /.22 KVA 50.04 TOTAL AM PAC ITY 56.79 AMPS 60.18 SERVICE AMPACITY 200 AMPS 200.00 SPARE CAPACITY AMPS 140 1 2 3 4 5 6 7 8 9 10 LCK Cl C2 Cl C1 /EM C2 Cl Cl C1 LCK LCK LCK LO LCK C2 LCK Cl C1 LO LCK LCK LCK C2 ELECTRICAL KEYED NOTES: El 200A DISCONNECT SWITCH PROVIDED BY THE LANDLORD FOR THE GODIVA CHOCOLATIER SPACE. PROVIDE IDENTIFICATION NAMEPLATE ON GODIVA'S DISCONNECT SWITCH IN LANDLORD'S SWITCHBOARD. REFER TO TENANT CRITERIA FOR NAMEPLATE REQUIREMENTS. ELECTRICAL GENERAL NOTES: 1. INCLUDE GROUND WIRE IN ALL RACEWAYS. SIZE RACEWAYS AS NECESSARY TO COMPLY WITH N.E.C. 2. VERIFY EXACT LOCATION OF ELECTRICAL DEVICES SHOWN ON THE ELECTRICAL CONSTRUCTION DOCUMENTS WITH ARCHITECTURAL, MECHANICAL, AND PLUMBING DRAWINGS PRIOR TO FINAL PLACEMENT. 3. PROVIDE A TYPED LISTING OF FINAL CIRCUIT ASSIGNMENTS PERMANENTLY ATTACHED TO PANELBOARDS WITH COPIES TO THE MANAGER AND OWNER. 4. BALANCE ALL PANELBOARDS AND ELECTRICAL EQUIPMENT TO +/- 10% BETWEEN PHASES: A /B, B /C, A/C REGARDLESS OF CIRCUITING INDICATED. 5. PROPER CLEARANCE MUST BE MAINTAINED ABOUT ELECTRICAL EQUIPMENT PER N.E.C. FIELD VERIFY EXACT MOUNTING SPACE AVAILABLE IN ELECTRICAL ROOM /AREA PRIOR TO INSTALLATION OF ELECTRICAL EQUIPMENT. 6. CONDUCTORS IN ONE -LINE DIAGRAMS MAY BE UPSIZED FOR VOLTAGE DROP. REPORT CHANGES TO ENGINEER. 7. FAULT CURRENT CALCULATED USING AN INFINITE BUS. VERIFY AND REPORT ACTUAL FAULT CURRENT FOR VERIFICATION OF DRAWINGS. 8. TELEPHONE CONDUIT TO BE ROUTED FROM DEMARK TO TELEPHONE TERMINAL BOARD IN GODIVA'S SPACE. 9. ELECTRICAL CONTRACTOR SHALL PROVIDE A TEMPORARY TRANSFORMER AND PANEL AS NECESSARY FOR CONSTRUCTION POWER. EX I STI \ EXISTING NEW ONE -LINE DIAGRAM NO SCALE G LA \DLORD LANDLORD ELECTRICAL ROOM 1 B I 73 I I 204 I G150 I I T154 I PNLBD H 200A 3P TXL I - I METERING EQUIPMENT 480Y/277V 30 4W TENANT SPACE #1020 -- BY TGC 200/3/200 II CVD= 0.3% FCA= 10,370A 480 14 80Y 277V J 208 /120V CVD= 0.5% FCA= 3,084A PNLBD L CIRCUIT SCHEDULE: ALL CONDUCTOR SIZES ARE BASED ON 75 DEG C RATED TERMINATION AND COPPER CONDUCTORS WITH TYPE THHN /THWN -2 INSULATION. WHERE ALUMINUM CONDUCTORS ARE ALLOWED PER SPECIFICATIONS AND FOR TERMINATION OR INSULATION TYPES RATED LESS THAN 75 DEG C, MODIFY SIZES ACCORDING TO NFPA 70. 70A, (3) #4, (1) #8G, 1" C 200A, (4) #3/0, (1) #6G, 2 C GND, #6 COPPER GROUND, 3/4" C 150A, (4) #1/0, (1) #6G, 1 -1/2" C Do oi RECrl > Pir FEB -8 ZOU PERMIT L:Lrq FCA= 18,437A HENDERSON ENGINEERS= 10370 RICHMOND AVENUE, SUITE 370 HOUSTON, TX 77042 TEL 713 783 7707 FAX 713 783 7797 www.hei eeg.cem 0750001294 RJ5 JMH SI M W o ff, LL 1 - ILI Q W I- I 0 U) 12/08/08 0 N 0 U ISSUED / REVISED DATE HEALTH DEPT SUBMITTAL 12.17.07 98% OWNER REVIEW 01.03.08 HEALTH DEPT RVSNS 01.11.08 ISSUED FOR PERMIT 01.25.08 ELECTRICAL PNLBD SCHED AND DETAILS E -3.0 6 9 10 16A: ELECTRICAL: 16A1 GENERAL CONDITIONS: A. THE REQUIREMENTS AS SET FORTH UNDER GENERAL CONDITIONS, INSTRUCTIONS TO BIDDERS AND GENERAL REQUIREMENTS ARE A PART OF THIS CONTRACT. B. BIDS SHALL BE BASED ON A COMPLETE /FULL SET OF DRAWINGS. C. CONTRACTOR MUST READ THE ENTIRE SPECIFICATIONS COVERING OTHER BRANCHES OF WORK AND IS RESPONSIBLE FOR COORDINATION OF THE WORK WITH WORK PERFORMED BY OTHER TRADES. 16A2 SCOPE OF WORK: A. CONTRACTOR SHALL VISIT SITE PRIOR TO BIDDING. BIDS SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDMONS. ALL REQUIREMENTS INCLUDING MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS ARE TO BE OBTAINED BY ELECTRICAL CONTRACTOR PRIOR TO AND INCLUDED IN BID PRICE. FIELD VERIFY ALL EXISTING ELECTRICAL AND TELEPHONE EQUIPMENT, LOCATIONS, CONDITIONS ETC. FAILURE TO VISIT THE SITE SHALL NOT RELIEVE THE CONTRACTOR FROM ANY RESPONSIBILITY IN THE PERFORMANCE OF THE ELECTRICAL WORK, B. FURNISH ALL LABOR, MATERIALS, TESTING, EQUIPMENT, INCIDENTALS AND TOOLS TO PERFORM ELECTRICAL WORK SHOWN, NOTED OR SCHEDULED FOR A COMPLETE AND FINISHED INSTALLATION. 1. MATERIALS, PRODUCTS AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW AND AS SUCH APPEAR ON THE UNDERWRITERS LABORATORIES LIST OF APPROVED ITEMS AND SHALL BE SIZED IN CONFORMITY WITH REQUIREMENTS OF THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE AND OTHER APPUCABLE CODES, WHICHEVER ARE MORE STRINGENT. C. THE WORK IS TO BE IN ACCORDANCE WITH THE LATEST EDITION OF THE NEC AND ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES. D. INCLUDE ANY LABOR AND MATERIALS NOT SPECIFICALLY MENTIONED, BUT NECESSARY TO PROVIDE A COMPLLIL AND FULLY OPERATIVE ELECTRICAL SYSTEMS. 16A3 PERMITS: A. SECURE AND PAY FOR ALL REQUIRED PERMITS, FEES, ASSESSMENTS AND INSPECTION CERTIFICATES THAT RELATE TO THE ELECTRICAL CONTRACT. B. FURNISH APPROVED CERTIFICATE OF FINAL INSPECTION, AND TURN OVER TO OWNER AT COMPLETION OF PROJECT. 16A4 DRAWINGS AND SPECIFICATIONS: A. THESE ELECTRICAL PLANS ARE DIAGRAMMATIC, NOT SHOWING EVERY ITEM IN EXACT LOCATION OR DETAIL MEASUREMENTS AND LOCATIONS MUST BE FIELD VERIFIED AND COORDINATED WITH ARCHITECTURAL, PLUMBING, HVAC, FIRE PROTECTION, STRUCTURAL AND OTHER BUILDING DRAWINGS. 16A5 SHOP DRAWINGS: A. SUBMIT FIVE COPIES OF MATERIAL LISTS AND SHOP DRAWINGS FOR MAJOR EQUIPMENT TO THE OWNER'S CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO ORDERING EQUIPMENT. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS EARLY ENOUGH IN PROJECT TO ALLOW AMPLE TIME FOR OWNER'S REVIEW WITHOUT CAUSING TIME DELAYS OR CONFLICTS IN THE JOB PROGRESS. SUBMITTALS SHALL BE IN ACCORDANCE WITH GENERAL CONDITIONS AND THE MANUFACTURERS LISTED ON THE DRAWINGS AND SHALL BEAR THE STAMP OF THE CONTRACTOR SHOWING THAT HE HAS REVIEWED AND APPROVED THEM AND THAT THEY ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS. LACK OF SUCH CONTRACTOR'S APPROVAL WILL BE CAUSE FOR REJECTION WITHOUT REVIEW BY THE OWNER. B. WHERE TRADE NAMES, BRANDS OF MANUFACTURERS OF EQUIPMENT OR MATERIALS ARE SHOWN ON THE DRAWINGS OR SPECIFICATIONS THE EXACT EQUIPMENT SHALL BE USED ON THE PROJECT. THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL /REPLACEMENT AT THE REQUEST OF THE OWNER'S CONSTRUCTION MANAGER (AT THE ELECTRICAL CONTRACTORS EXPENSE). 16A6 CONDUITS: A. CONDUIT SHALL BE STANDARD STEEL RIGID, IMC OR EMT (THIN WALL) ACCORDING TO LOCAL CODE AND LANDLORD REQUIREMENTS. CONDUIT SHALL BE CONCEALED IN FINISHED AREAS, EXCEPT AS OTHERWISE APPROVED BY ARCHITECT. EMT CONNECTIONS SHALL BE COMPRESSION TYPE. B. FLEXIBLE METAL CONDUIT SHALL BE USED FOR FINAL CONNECTIONS TO LIGHT FIXTURES, MOTORS AND VIBRATING EQUIPMENT ONLY; AND WHERE SO USED TO BE GROUNDED WITH A SEPARATE FULL SIZED GREEN GROUNDING CONDUCTOR. FINAL FLEXIBLE METAL CONDUIT CONNECTIONS SHALL BE LIMITED TO 5' -0" IN LENGTH. (ARRANGE CIRCUITS SO AS TO AVOID THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILING AREAS, JUNCTION BOXES LOCATED ABOVE LAY IN CEILINGS ARE ACCEPTABLE). 1. MINIMUM SIZES OF CONDUITS SHALL BE 3/4 ". ELECTRIC METALLIC TUBING (EMT) SHALL BE GALVANIZED OR ELECTRO- GALVANIZED. FITTINGS SHALL BE SET SCREW OR COMPRESSION TYPE, FITTING SHALL BE AS MANUFACTURED BY REGEL, STEEL CITY, RACO, T & B, EFCOR OR EQUAL. EMT SHALL BE USED FOR FEEDERS AND BRANCH CIRCUITS RUN ABOVE SUSPENDED CEILINGS OR CONCEALED IN INTERIOR PARTITIONS. 2. PAINTING OF ELECTRICAL CONDUITS, ETC., IF REQUIRED, WILL BE BY GENERAL CONTRACTOR. C. THE USE OF AC, MC, NM, ROMEX, OR BX IS NOT PERMITTED. D. MAXIMUM CONDUIT HANGER SPACING SHALL BE 8' -0" FOR 3/4" THRU 1 1/4" AND 10' -0" FOR 1 1/2" THRU 4" CONDUITS. DO NOT SUPPORT CONDUIT FROM THE CEILING SYSTEM. E. LEAVE A 1110 AWG PULL WIRE OR NYLON PULL STRING IN ALL EMPTY CONDUITS. F. SECURE ALL RACEWAYS TO THE BUILDING STRUCTURE IN A RIGID AND SECURE MANNER, USING FASTENERS SUCH AS "CADDY CUPS" OR EQUAL. G. FLASH AND COUNTER FLASH ALL RACEWAYS WHICH PENETRATE THE ROOF OR USE PITCH POCKETS. INSURE THAT PENETRATIONS ARE COMPLETELY WEATHERPROOF. ALL RACEWAY SYSTEMS EXPOSED TO THE WEATHER SHALL BE WEATHERPROOF. PRIOR APPROVAL BY LANDLORD IS REQUIRED TO ADD ADDITIONAL EQUIPMENT LOADS TO STRUCTURE OR TO MAKE HOLES IN EXISTING ROOF. NOTIFY LANDLORD'S ROOFING CONTRACTOR AT LEAST 72 HOURS PRIOR TO ANY REQUIRED ROOF WORK. H. SLAB OPENINGS FOR CONDUITS IN WET AREAS MUST BE SLEEVED 2" ABOVE FLOOR AND SEALED TO PROPER FLOOR WATERPROOFING SYSTEM PER B -2. X -RAY SLAB PRIOR TO CORE DRILLING. 16A7 WIRE: A. WIRE SHALL BE SINGLE CONDUCTOR COPPER WITH 600 VOLT INSULATION. MINIMUM WIRE SIZE SHALL BE #12 AWG, ALL WIRE AND CABLE SHALL BE NEW AND SHALL BE BROUGHT TO THE SITE IN UNBROKEN PACKAGES. ALL WIRING OF ANY TYPE SHALL BE IN CONDUIT. NO STRANDED WIRE ALLOWED FOR #10 AND #12 AWG SIZES. (INCREASE CONDUCTOR BY ONE SIZE FOR EVERY 150' INCREMENT OF DISTANCE FROM THE PANEL BOARD FOR 120 VOLT CIRCUITS.) 1. GENERAL WIRING SHALL BE THW OR THHN. (ALUMINUM CONDUCTORS ARE NOT PERMITTED.) WIRE CONNECTORS SHALL BE EQUAL TO SCOTCHLOCK FOR #8 AND SMALLER, AND EQUAL TO T & B "LOCK -TITE" FOR #6 AND LARGER. B. C. THE USE OF SHARED NEUTRALS IS ACCEPTABLE FOR LIGHTING AND RECEPTACLE CIRCUITS IF INSTALLED IN ACCORDANCE WITH N.E.C. #310, AND LOCAL CODES. D. ALL WIRING TO BE COLOR CODED AS FOLLOWS: 120/208 VOLT SYSTEM NEUTRAL - WHITE PHASE A OR Li- -BLACK PHASE B OR L2 -RED PHASE C OR L3-BLUE GROUND -GREEN 277/480 VOLT SYSTEM NEUTRAL - WHITE WITH TRACER OR GRAY PHASE A OR L1 - BROWN PHASE B OR L2- ORANGE PHASE C OR L3- YELLOW GROUND -GREEN WITH TRACER 16A8 LIGHTING: A. LIGHTING FIXTURES AND LAMPS SHALL BE FURNISHED AS SCHEDULED ON THE LIGHTING FIXTURE SCHEDULE. (THE MAJORITY OR THE FIXTURES AND LAMPS ARE FURNISHED BY THE TENANT) ELECTRICAL CONTRACTOR SHALL INSTALL ALL FIXTURES AND LAMPS. FLUORESCENT FIXTURES SHALL HAVE HPF BALLASTS WITH EFFICIENCY FACTORS IN ACCORDANCE WITH "NATIONAL APPLIANCE ENERGY CONSERVATION ACT OF 1987, AMENDMENTS OF 1988." B. LIGHT FIXTURES SHALL BE SUPPORTED FROM THE BUILDING STRUCTURAL VIA ALL THREAD AND UNISTRUT, AND NOT SUPPORTED BY CEILING SYSTEM. 16A9 WIRED GROUND SYSTEM: A. FURNISH AND INSTALL A COMPLETE WIRED GROUNDING SYSTEM FOR ELECTRICAL EQUIPMENT AND CIRCUITS AS SHOWN ON THE DRAWINGS AND DESCRIBED GENERALLY BELOW. B. ALL GROUNDING CONDUCTORS SHALL BE GREEN, WHERE EXPOSED IN PANEL, SWITCHBOARD, OUTLET, BOXES, ETC. C. ALL ENCLOSURES AND NON CURRENT CARRYING METALS TO BE GROUNDED. CONDUIT SYSTEM TO BE ELECTRICALLY CONTINUOUS. ALL LOCK NUTS MUST CUT THROUGH ENAMELED OR PAINTED SURFACES ON ENCLOSURES. WHERE ENCLOSURES AND NON CURRENT CARRYING METALS ARE ISOLATED FROM THE CONDUIT SYSTEM, USE BONDING JUMPERS WITH APPROVED CLAMPS. 0. RUN A SEPARATE GROUNDING CONDUCTOR IN EACH CONDUIT, #12 MINIMUM, OR AS SHOWN ON DRAWINGS. FOR PANEL FEEDERS BOND THE GROUNDING CONDUCTOR TO THE CONDUIT, WHERE ENTERING AND LEAVING THE CONDUIT. ALL GROUND CLAMPS SHALL BE PENN -UNION OR EQUAL, SIMILAR TO "GPL" TYPE. CONDUIT GROUND BUSHINGS SHALL BE THOMAS & BETTS OR EQUAL, SIMILAR TO #3800 SERIES WITH NYLON INSULATED THROAT. E. ALL DEVICES SHALL BE BONDED TO THE CONDUIT SYSTEM. USE A BONDING JUMPER BETWEEN THE OUTLET BOX AND THE DEVICE GROUNDING TERMINAL METAL TO METAL CONTACT BETWEEN THE DEVICE YOKE AND THE OUTLET BOX IS NOT ACCEPTABLE AS A BOND FOR EITHER SURFACE MOUNTED BOXES OR FLUSH TYPE BOXES. ALL JUNCTION BOXES, OUTLET BOXES AND PULL BOXES SHALL BE BONDED TO THE CONDUIT SYSTEM. ALL FLEXIBLE CONDUIT SHALL BE JUMPERED WITH A GROUND CONDUCTOR. 16A10 WIRE DEVICES: A. COLOR OF WIRING DEVICES SHALL BE IVORY. 1. RECEPTACLES SHALL BE 20 AMP, 3 -WIRE GROUNDING TYPE EQUAL TO HUBBELL 5362. 2. SWITCHES SHALL BE 20 AMP SPECIFICATION GRADE, RATED AT 120 OR 277 VOLT, AS REQUIRED. 3. SPECIAL DEVICES SHALL BE A SPECIFICATION GRADE. 4. ALL DEVICE COVER PLATES SHALL BE BRASS. 5. FLOOR BOXES TO BE HUBBELL #B- 2527/29 WITH 5 -3925 BRASS COVER (OR EQUAL BY "STEEL CITY") AND HUBBELL 5362 RECEPTACLE (UNLESS OTHERWISE NOTED). 6. EQUAL BY ARROW -HART, GENERAL ELECTRIC, BRYANT, PASS & SEYMOUR, OR SIERRA. 16A11 PANELBOARDS AND SAFETY SWITCHES: A. PROVIDE BRANCH CIRCUIT PANELS WHICH SHALL BE OF THE BOLTED CIRCUIT BREAKER TYPE WITH SOLID COPPER BUSSING FULL SIZED NEUTRAL, 25% GROUND BUSSING, OVERALL HINGED /LOCKABLE DOOR, AND TYPE WRITTEN DIRECTORY INSIDE DOOR. ALL SERVICE ENTRANCE EQUIPMENT SHALL BEAR THE MANUFACTURER'S LABEL WHICH SHALL STATE THAT THE EQUIPMENT IS RATED FOR SERVICE ENTRANCE APPLICATION IN ACCORDANCE WITH N.E.C. #230 -70. LOAD BALANCE ALL ELECTRICAL PHASES AT PANELS AND SWITCHBOARDS. TWO AND THREE POLE BREAKERS SHALL BE COMMON TRIP TYPE. WHEN USED AS SWITCHES IN 120V. AND 277V. LIGHTING CIRCUITS, FURNISH TYPE "SWD" BREAKERS IN ACCORDANCE WITH N.E.C. #240 -83B. SQUARE D OR EQUAL BY GOULD ITE, CUTLER - HAMMER, WESTINGHOUSE, CHALLENGER, FEDERAL PACIFIC, OR GENERAL ELECTRIC (OR APPROVED EQUAL). B. PROVIDE SAFETY AND DISCONNECT SWITCHES, FUSED OR NON FUSED, AS CALLED FOR ON DRAWINGS AND AS REQUIRED BY CODE. (FUSES AS MANUFACTURED BY BUSSMAN, CHASE SHAWMUT, WESTINGHOUSE, ECONOMY FUSE CO., OR LITTLE FUSE CO. ARE ACCEPTABLE). DISCONNECT SWITCHES THAT ARE INSTALLED AT AIR CONDITIONING EQUIPMENT, HEAT PUMPS, ETC. SHALL BE FUSED IN ACCORDANCE WITH THE EQUIPMENT'S NAME PLATE REQUIREMENTS PER N.E.C. 440 -21 & 110 -3B. SWITCHES SHALT. BE HEAVY DUTY, QUICK MAKE /QUICK BREAK TYPE, FUSIBLE OR NON FUSIBLE, WEATHERPROOF AS INDICATED ON THE DRAWINGS, OR AS REQUIRED BY LOCAL CODES. LOAD AND HORSEPOWER RATED AS MANUFACTURED BY SQUARE D, GOULD ITE, CHALLENGER, CUTLER HAMMER, WESTINGHOUSE, FEDERAL PACIFIC, OR GENERAL ELECTRIC (OR APPROVED EQUAL). C. MANUAL MOTOR STARTERS WITH OVERLOAD PROTECTION MAY BE USED FOR FRACTIONAL HORSEPOWER MOTORS THAT DO NOT REQUIRE AUXILIARY CONTROL. SINGLE PHASE STARTERS SHALL BE SQUARE D OR EQUAL THREE PHASE STARTERS SHALL BE PROVIDED WITH OVERLOAD DEVICE IN EACH PHASE MATCHED TO MOTOR NAMEPLATE RATING. MAGNETIC MOTOR STARTERS (MINIMUM SIZE #1) SHALL BE USED FOR ALL SINGLE PHASE AND THREE PHASE MOTORS RATED ABOVE 1/2 HP OR THAT REQUIRE AUXILIARY CONTROL PROVIDE CONTROL DEVICES (CONTACTS, TRANSFORMERS, ETC.) IN STARTERS AS REQUIRED FOR INTERLOCKS, COORDINATE WITH MECHANICAL AND /OR TEMPERATURE CONTROL CONTRACTORS. COMBINATION STARTERS, WHEN USED, SHALL CONTAIN FUSIBLE SWITCHES. 16Al2 BOXES: A. OUTLET BOXES AND COVERS SHALL BE GALVANIZED, ONE PIECE PRESSED STEEL KNOCKOUT. B. JUNCTION, PULL BOXES AND COVERS SHALL BE GALVANIZED STEEL, CODE GAUGE SIZE. C. INSTALL BOXES RIGIDLY ON BUILDING STRUCTURE AND SUPPORT INDEPENDENTLY OF THE CONDUIT SYSTEM. ALSO PROVIDE SUITABLE /PROPER BOX EXTENSIONS TO EXTEND BOXES TO FINISHED FACES OF WALLS ETC. ALL OUTLET BOXES TO HAVE SUITABLE BLOCKING BEHIND THEM TO MINIMIZE THE DEFLECTION THAT OCCURS WHEN PLUGGING /UNPLUGGING INTO THESE DEVICES. D. WHERE A 277 VOLT LIGHT SWITCH IS GANGED WITH A 120 VOLT RECEPTACLE PROVIDE A SUITABLE DIVIDER OR SEPARATE JUNCTION BOXES IN ACCORDANCE WITH NEC AND LOCAL CODES. 16A13 SERVICES: A. ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY SERVICE FROM LANDLORD'S DESIGNATED LOCATION AND PROVIDE LIGHTING, POWER AND WIRING AS REQUIRED TO FACILITATE APPUCABLE TEMPORARY NEEDS, AND FURNISH EXTENSION CORDS. ANY TEMPORARY WIRING, FUSES, ETC., SHALL BE REMOVED UPON COMPLETION OF THE PROJECT. PROVIDE GROUND FAULT PROTECTION AS REQUIRED BY N.E.C. AND LOCAL CODES. B. PROVIDE ELECTRICAL SERVICE AS SHOWN ON THE DRAWINGS, FIELD VERIFY EXACT REQUIREMENTS PRIOR TO BIDS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR POWER COMPANY SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. CLOSELY COORDINATE ENTIRE INSTALLATION WITH LANDLORD AND POWER COMPANY AS REQUIRED. (PROVIDE EQUIPMENT THAT IS COMPATIBLE WITH AVAILABLE FAULT CURRENT LEVELS, PROVIDE "CABLE LIMITERS" IF NECESSARY FOR SYSTEM COORDINATION). FIELD VERIFY EXACT TYPE, SIZE, LOCATION, REQUIREMENTS, ETC. OF EXISTING POWER AND TELEPHONE FACILITIES PRIOR TO BIDDING PROJECT. C. MAKE PROVISIONS FOR NEW TELEPHONE SERVICE AS REQUIRED, AND AS INDICATED ON THE DRAWINGS. D. CONDUIT SYSTEM FOR TELEPHONE DISTRIBUTION WITHIN TENANT'S PREMISES SHALL BE PROVIDED AS REQUIRED FOR A COMPLETE TELEPHONE SYSTEM. OUTLET BOXES SHALL BE 4" SQUARE MINIMUM WITH SINGLE DEVICE COVER AND TELEPHONE PLATE. CLOSELY FIELD COORDINATE WITH TENANTS CONSTRUCTION MANAGER TO AVOID CONFLICTS. 16A14 STEP -DOWN TRANSFORMER: A. PROVIDE A DRY -TYPE TRANSFORMER OF THE ENCLOSED VENTILATED TYPE WITH KVA AND VOLTAGE RATINGS AS CALLED FOR ON THE DRAWINGS AND WITH COILS DESIGNED FOR 150 DEGREES C. RISE ABOVE A 40 DEGREE C. AMBIENT WITH 100% OF RATED LOAD CONNECTED TO THE SECONDARY, CLASS H INSULATION AND MINIMUM OF SIX STANDARD FULL CAPACITY TAPS. (TWO ABOVE AND FOUR BELOW NORMAL) SOUND LEVEL /DECIBELS SHALL BE IN ACCORDANCE WITH "NEMA" STANDARDS, AND INSTALLATION SHALL INCLUDE KORFOUND OR EQUAL VIBRATION DAMPENING MOUNTS AND FLEXIBLE STEEL CONDUIT FOR PRIMARY AND SECONDARY CONNECTIONS TO MINIMIZE SOUND TRANSMISSION. (MOUNT TRANSFORMER ON SEPARATE VIBRATION ISOLATORS, THESE ARE ADDITIONAL VIBRATION ISOLATORS AND ARE USED IN CONJUNCTION WITH ANY INTEGRAL FACTORY INSTALLED VIBRATION ISOLATORS.) AS MANUFACTURED BY SQUARE D, HEAVY DUTY, ACME, GENERAL ELECTRIC OR WESTINGHOUSE. 16A15 LIGHTING CONTACTOR: A. WHERE INDICATED ON THE DRAWINGS, CONTACTORS FOR CONTROL OF LIGHTING SHALL BE SQUARE D CLASS 8903, TYPE 'L' IN A NEMA 1 ENCLOSURE, ELECTRICALLY OPERATED, AND ELECTRICALLY HELD. EQUALS BY SIEMENS -ITE, GENERAL ELECTRIC, OR WESTINGHOUSE, NO EXCEPTIONS. TIME SWITCHES FOR CONTROL OF SHOW WINDOW LIGHTING AND SIGNS SHALL BE TORK MODEL NO. W220L, 7 DAY TYPE, WITH RESERVE POWER, OR EQUIVALENT BY SANGAMO OR PARAGON. 16A16 INSTALLATION: A. ALL ELECTRIC WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING AND REPAIRING. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS CHANNELS, RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK AND SHALL BE FASTENED TO BUILDING STEEL, CONCRETE OR MASONRY, BUT NOT PIPING OR DUCTWORK. ALL CONDUIT SHALL BE CONCEALED WHEREVER POSSIBLE. EXPOSED CONDUITS SHALL BE IN STRAIGHT LINES PARALLEL WITH OR AT RIGHT ANGLES TO COLUMN LINES OR BEAMS AND SEPARATED AT LEAST 3 INCHES FROM WATER LINES WHEREVER THEY RUN ALONGSIDE OR ACROSS SUCH LINES. ALL CONDUCTORS SHALL BE IN CONDUIT, DUCTS OR OTHER CODE APPROVED RACEWAYS. B. ALL LINE AND LOW VOLTAGE POWER AND CONTROL WIRING (EXCEPT HVAC LOW VOLTAGE WIRING) INCLUDING CONNECTIONS TO MOTORS, DAMPERS, INTERLOCKING, ETC., SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. (ALL LINE VOLTAGE WIRING, CONDUIT, AND FINAL CONNECTIONS FROM THE POWER SOURCE THRU THE STARTER /DISCONNECT ETC. TO THE MOTOR OR EQUIPMENT IS THE RESPONSIBILITY OR THE ELECTRICAL CONTRACTOR. ALL HVAC RELATED LOW VOLTAGE CONTROL WIRING, CONDUIT AND FINAL CONNECTIONS IS THE RESPONSIBILITY OF THE MECHANICAL/TEMPERATURE CONTROL CONTRACTOR, UNLESS OTHERWISE NOTED ON THE PLANS). C. THE ELECTRICAL CONTRACTOR SHALL DO ALL CUTTING, CHASING OR CHANNELING AND PATCHING REQUIRED FOR ANY WORK UNDER THE ELECTRICAL DMSION, ANY CUTTING SHALL HAVE PRIOR APPROVAL OF THE LANDLORD. SLEEVES SHALL EXTEND AT LEAST TWO (2 ") INCHES ABOVE FINISHED FLOOR AND ALL SLEEVES, OPENINGS, ETC., THROUGH FIRE RATED WALLS AND FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE, SILICONE "RN" FOAM, "3M" FIRE RATED SEALANTS OR EQUAL BY HILTI AFTER CONDUIT /CABLES INSTALLATION SO AS TO RETAIN THE FIRE RATING. D. THE ELECTRICAL CONTRACTORS, INSOFAR AS THE WORK IS CONCERNED, SHALL AT ALL TIMES KEEP THE PREMISES IN A NEAT AND ORDERLY CONDITION AND, AT THE COMPLETION OF THE WORK, SHALL PROPERLY CLEAN UP AND CART AWAY ANY DEBRIS AND EXCESS MATERIAL. E. THE FOLLOWING EQUIPMENT SHALL BE IDENTIFIED WITH ENGRAVED BAKELITE NAMEPLATES AS TO NAME AND /OR FUNCTION; DISTRIBUTION PANELS, LIGHTING PANELS, MOTOR STARTERS AND DISCONNECT SWITCHES. NAMEPLATES TO BE APPROXIMATELY 1" X 2" IN SIZE AND BE FASTENED WITH POP RIVETS OR SCREWS. F. THE LOCATION OF OUTLETS AND EQUIPMENT SHOWN ON THE DRAWINGS ARE APPROXIMATE AND THE ARCHITECT /TENANT CONSTRUCTION MANAGER SHALL HAVE THE RIGHT TO RELOCATE ANY OUTLETS OR FIXTURES BEFORE THEY ARE INSTALLED WITHOUT ADDITIONAL COST. G. ELECTRICAL CONTRACTOR SHALL RECORD ALL FIELD CHANGES IN THE WORK AS THE JOB PROGRESSES, AND TURN THIS AS BUILT" INFORMATION OVER TO THE OWNER AT THE COMPLETION OF THE PROJECT. H. ELECTRICAL CONTRACTOR SHALL PROTECT ALL FIXTURES /EQUIPMENT AGAINST DAMAGE FROM LEAKS, ABUSE, ETC., AND PAY COST OF REPAIR OR REPLACEMENT OF FIXTURES OR EQUIPMENT MADE NECESSARY BY FAILURE TO PROVIDE SUITABLE SAFEGUARDS OR PROTECTION. I. ALL ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL CONNECTIONS AS REQUIRED FOR A COMPLETE AND OPERATING SYSTEM. AFTER ALL EQUIPMENT HAS BEEN INSPECTED AND APPROVED, THOROUGHLY CLEAN ALL EQUIPMENT PROVIDED UNDER THIS WORK JUST PRIOR TO COMPLETION OF PROJECT. J. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ANY /ALL NECESSARY ELECTRICAL DEMOLITION WORK THAT IS REQUIRED TO FACILITATE THE NEW INSTALLATION, FIELD COORDINATE PRIOR TO BIDS. REMOVE AND /OR MODIFY EQUIPMENT, ETC. AS REQUIRED FOR A COMPLETE INSTALLATION. ANY EQUIPMENT OR DEVICE REMAINING IN USE AFTER PART OF THE EQUIPMENT OR DEVICES HAVE BEEN REMOVED ARE TO BE RECONNECTED TO EXISTING OR NEW CIRCUITS AND LEFT IN WORKING ORDER. FEEDERS TO PANELS AND WIRING TO OTHER EQUIPMENT TO BE ROUTED CONCEALED IN FINISHED AREAS. COORDINATE ANY DISRUPTION OF ELECTRICAL OR TELEPHONE SERVICES WITH LANDLORD AND TENANT CONSTRUCTION MANAGER TO AVOID CONFLICTS. 16A17 GUARANTEE: A. MATERIALS, EQUIPMENT AND INSTALLATION SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE. DEFECTS WHICH APPEAR DURING THAT PERIOD SHALL BE CORRECTED AT THE ELECTRICAL CONTRACTOR'S EXPENSE. B. FOR THE SAME PERIOD, ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO PREMISES CAUSED BY DEFECTS IN WORKMANSHIP OR IN THE WORK OR EQUIPMENT FURNISHED AND /OR INSTALLED BY THE ELECTRICAL CONTRACTOR. 16A18 TELEPHONE: A. LANDLORD WILL PROVIDE A COMMUNICATION CABLE TRAY LOCATED IN THE UTILITY CORRIDOR FOR TENANT'S USE. NO CONDUIT WILL BE PROVIDED. LANDLORD WILL PROVIDE A COMMUNICATIONS TERMINAL BOARD WITHIN EACH LANDLORD ELECTRICAL ROOM. TENANT SHALL PROVIDE AND INSTALL A COMPLETE TELEPHONE SERVICE SUPPORT FACILITIES AS REQUIRED BY THE SERVING TELEPHONE COMPANY. ALL TENANT TELEPHONE EQUIPMENT SHALL BE CONTAINED WITHIN THE TENANT'S SPACE. TENANT'S TELEPHONE EQUIPMENT IS NOT PERMIIILD IN LANDLORD'S TELEPHONE EQUIPMENT ROOM. TENANT SHALL PROVIDE PLENUM RATED WIRE FROM THE TELEPHONE ROOM TO THE TENANT'S TELEPHONE EQUIPMENT WITHIN THE DEMISED PREMISES UTILIZING THE LANDLORD SUPPLIED CABLE TRAY. ANY CORRIDOR WALL PENETRATIONS WILL NEED TO BE FIRE CAULKED AS REQUIRED. 16A19 FINALLY: A. IT IS THE INTENT THAT THE FOREGOING WORK SHALL BE COMPLETE IN EVERY RESPECT AND THAT ANY MATERIAL OR WORK NOT SPECIFICALLY MENTIONED OR SHOWN ON THE DRAWINGS, BUT NECESSARY TO FULLY COMPLETE THE WORK SHALL BE FURNISHED. D sO17 RECF 1VE FEB - 8 2008 PERMIT CENTER HENDERSON ENGINEERS= 10370 RICHMOND AVENUE, SUITE 370 HOUSTON, TX 77042 TEL 713 783 7707 pax 713 783 7797 www.hei-eng.com 0750001294 R1S 1MH SI.M ISSUED / REVISED DATE HEALTH DEPT SUBMITTAL 12.17.07 98% OWNER REVIEW 01.03.08 HEALTH DEPT RVSNS 01.11.08 ISSUED FOR PERMIT 01.25.08 12/08/ E -4.0 at taa C) ELECTRICAL SPECIFICATIONS 1 2 3 4 5 6 7 8 9 10 SECTION 16C FIRE ALARM SYSTEM: 16C1 GENERAL 16C 1 -1 GENERAL REQUIREMENTS THE WORK COVERED BY THIS SECTION OF THE SPECIFICATIONS INCLUDES THE FURNISHING OF ALL LABOR, EQUIPMENT, AND MATERIAL AS HEREIN SPECIFIED. THIS SECTION REQUIRES THE CONTRACTOR TO FURNISH ALL MATERIALS REQUIRED TO INSTALL THE FIRE ALARM SYSTEM. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING, TESTING, AND START —UP OF A COMPLETE FUNCTIONING FIRE ALARM SYSTEM, AND EACH ELEMENT THEREOF, AS SPECIFIED OR INDICATED ON THE DRAWINGS OR REASONABLY INFERRED, INCLUDING EVERY ARTICLE, DEVICE OR ACCESSORY (WHETHER OR NOT SPECIFICALLY CALLED FOR BY ITEM) REASONABLY NECESSARY TO FACILITATE EACH SYSTEM'S FUNCTION AS INDICATED BY THE DESIGN AND THE EQUIPMENT SPECIFIED. ELEMENTS OF THE WORK INCLUDE MATERIALS, LABOR, SUPERVISION, SUPPLIES, EQUIPMENT, TRANSPORTATION AND UTILITIES. INSTALLATION OF DEVICES SHALL BE PERFORMED OR SUPERVISED BY A NATIONAL INSTITUTE FOR CERTIFICATION OF ENGINEERING TECHNOLOGIES (NICET) LEVEL 2 OR HIGHER FIRE ALARM TECHNICIAN. SUBMIT COPIES OF THE CERTIFICATION FOR EMPLOYEES THROUGH SHOP DRAWING SUBMITTALS. 16C 1 -2 SCOPE OF WORK THE SCOPE OF WORK IN THIS SECTION INCLUDES: EXTENSION OF THE EXISTING LANDLORD'S FIRE ALARM SYSTEM FOR NEW TENANT SPACE TO INCLUDE FIRE ALARM NOTIFICATION APPLIANCES; AUXILIARY FIRE ALARM EQUIPMENT; SPRINKLER SYSTEM WATERFLOW AND VALVE TAMPER ALARMS; AIR HANDLING UNIT SHUTDOWN; DUCT SMOKE DETECTORS. 16C 1 -3 CODES AND STANDARDS PROVIDE AN INTEGRATED FIRE ALARM SYSTEM, WHICH MEETS THE CURRENT VERSIONS OF NFPA 70, NATIONAL ELECTRICAL CODE; NFPA 72, NATIONAL FIRE ALARM CODE; AND ALL LOCAL BUILDING AND FIRE CODES. ALL FIRE ALARM EQUIPMENT SHALL BE UNDERWRITERS LABORATORY (UL) OR FACTORY MUTUAL (FM) APPROVED FOR THE TYPE AND CLASS OF SERVICE PERFORMED. 16C 1-4 SYSTEM DESCRIPTION THE FIRE ALARM SYSTEM SHALL BE A NON —CODED MANUAL AND AUTOMATIC FIRE ALARM SYSTEM WITH CONNECTION TO THE EXISTING LANDLORD'S FIRE ALARM CONTROL PANEL. CONTROL PANEL IS EXISTING TO REMAIN IN LANDLORD SPACE. 16C 1 -5 SUBMITTAL REQUIREMENTS SUBMIT A DETAILED SEQUENCE OF OPERATION. PRE — PRINTED, GENERIC MATERIAL WILL NOT BE ACCEPTED AND WILL BE REJECTED. SHOP DRAWINGS SHOWING FIRE ALARM FLOOR PLANS AND A FULL BUILDING RISER DIAGRAM. FIRE ALARM FLOOR PLANS AND RISER DIAGRAM SHALL SHOW FIRE ALARM CONTROL PANEL, ANNUNCIATOR, ALL FIRE ALARM INITIATING DEVICES AND NOTIFICATION APPLIANCES. SHOW TYPICAL WIRING DIAGRAMS OF CONTROL PANEL /S, ANNUNCIATOR AND EACH DEVICE AND WIRING CONNECTIONS REQUIRED. SHOW ALL INTERFACES TO OTHER SYSTEMS, SUCH AS TEMPERATURE CONTROL SYSTEMS, AND SECURITY SYSTEMS. SUBMIT A BILL OF MATERIAL AND MANUFACTURERS PRODUCT DATA FOR ALL DEVICES AND EQUIPMENT. 16C 1 -6 QUALIFICATIONS THE MANUFACTURER SHALL BE A COMPANY SPECIALIZING IN MANUFACTURING THE PRODUCTS SPECIFIED IN THIS SECTION WITH MINIMUM THREE YEARS DOCUMENTED EXPERIENCE. THE INSTALLER SHALL BE A COMPANY SPECIALIZING IN INSTALLING THE PRODUCTS SPECIFIED IN THIS SECTION WITH MINIMUM THREE YEARS DOCUMENTED EXPERIENCE. SHALL BE BONDABLE AND LICENSED CONTRACTOR AND MERCHANT OF ELECTRONIC AUTOMATED FIRE ALARM SYSTEMS AND EMPLOY FULL —TIME FACTORY — TRAINED INSTALLERS AND TECHNICIANS. THE EQUIPMENT MANUFACTURER'S SERVICE DEPARTMENT SHALL BE FULLY STOCKED IN STANDARD PARTS AND COMPONENTS AND ENGAGED IN THE MAINTENANCE OF FIRE ALARM SYSTEMS. ON—THE—PREMISES SERVICE SHALL BE AVAILABLE WITHIN 4 HOURS OF NOTIFICATION, 7 DAYS A WEEK, 24 HOURS A DAY. FURNISH SERVICE AND MAINTENANCE OF FIRE ALARM SYSTEM FOR ONE YEAR FROM DATE OF SUBSTANTIAL COMPLETION. 16C 1 -7 SERVICE AND GUARANTEE FURNISH SERVICE AND MAINTENANCE OF FIRE ALARM SYSTEM INCLUDING WIRING AND RACEWAYS FOR ONE YEAR FROM DATE OF SUBSTANTIAL COMPLETION. ALL COMPONENTS, SYSTEM SOFTWARE, PARTS AND ASSEMBLIES SHALL BE GUARANTEED AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP FOR ONE —YEAR. LABOR (INCLUDING TRAVEL EXPENSES) TO TROUBLE — SHOOT, REPAIR, REPROGRAM, OR REPLACE COMPONENTS SHALL BE FURNISHED BY THIS CONTRACTOR AT NO CHARGE DURING THE WARRANTY PERIOD. ALL CORRECTIVE SOFTWARE MODIFICATIONS MADE DURING WARRANTY PERIODS SHALL BE UPDATED ON ALL USER DOCUMENTATION AND ON USER AND MANUFACTURER ARCHIVED SOFTWARE DISKS. 16C 2 EQUIPMENT 16C 2--1 MANUFACTURERS SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS THAT ARE COMPATIBLE WITH THE EXISTING FIRE ALARM SYSTEM. 16C 2 -2 FIRE ALARM CONTROL PANEL THE FIRE ALARM CONTROL PANEL IS EXISTING TO REMAIN IN LANDLORD SPACE. POWER SUPPLY: PROVIDE TWO SEPARATE AND RELIABLE POWER SUPPLIES. THE CONTROL PANEL SHALL RECEIVE 120 VAC POWER VIA A DEDICATED FUSED DISCONNECT CIRCUIT OF THE BUILDING'S ELECTRICAL SYSTEM. EACH SHALL HAVE ADEQUATE CAPACITY FOR THE SYSTEM. THE FIRE ALARM CONTRACTOR SHALL SUBMIT BATTERY CALCULATIONS FOR REVIEW AND APPROVAL. THE CALCULATIONS SHALL INDICATE EACH DEVICE AND THE LOAD REQUIRED IN STAND —BY AND ALARM MODE. THE SECONDARY POWER SYSTEM SHALL BE A BATTERY — OPERATED EMERGENCY POWER SUPPLY AND CHARGER WITH CAPACITY FOR OPERATING SYSTEM IN STANDBY MODE FOR 60 HOURS FOLLOWED BY ALARM MODE FOR 5 MINUTES. SYSTEM SUPERVISION: AUTOMATICALLY DETECTS AND REPORTS OPEN CIRCUITS, SHORTS, AND GROUNDS OF WIRING FOR INITIATING DEVICE, SIGNALING LINE, AND NOTIFICATION APPUANCE CIRCUITS. ALARM, SUPERVISORY AND TROUBLE SIGNALS SHALL BE MONITORED BY THE SUPERVISING STATION OVER A DIGITAL ALARM COMMUNICATOR TRANSMITTER (DACT), OR OTHER APPROVED METHOD. INITIATING DEVICE CIRCUITS: PROVIDE CIRCUITRY, WHICH MEETS THE PERFORMANCE REQUIREMENTS DURING ABNORMAL CONDITIONS, BASED UPON THE STYLE AND CLASS OF THE CIRCUITRY SELECTED. INITIATING DEVICE CIRCUITS SHALL BE CLASS B, STYLE B. NOTIFICATION APPLIANCE CIRCUITS: PROVIDE CIRCUITRY, WHICH MEETS THE PERFORMANCE REQUIREMENTS DURING ABNORMAL CONDITIONS, BASED UPON THE STYLE AND CLASS OF THE CIRCUITRY SELECTED. NOTIFICATION APPLIANCE CIRCUITS SHALL BE CLASS B, STYLE Y. SIGNALING LINE CIRCUITS: PROVIDE CIRCUITRY, WHICH MEETS THE PERFORMANCE REQUIREMENTS DURING ABNORMAL CONDITIONS, BASED UPON THE STYLE AND CLASS OF THE CIRCUITRY SELECTED. SIGNALING LINE CIRCUITRY SHALL BE CLASS B, STYLE 4. AUXILIARY RELAYS: PROVIDE SUFFICIENT SPDT AUXILIARY RELAY CONTACTS TO PROVIDE ACCESSORY FUNCTIONS SPECIFIED. 16C 2 -3 SEQUENCE OF OPERATIONS THE SEQUENCE OF OPERATION SHALL MATCH THAT OF THE EXISTING LANDLORD'S SYSTEM OR MEET THE CRITERIA LISTED BELOW AT A MINIMUM. TROUBLE SEQUENCE OF OPERATION: SYSTEM OR CIRCUIT TROUBLE PLACES SYSTEM IN TROUBLE MODE, WHICH CAUSES THE FOLLOWING SYSTEM OPERATIONS: 1) VISIBLE AND AUDIBLE TROUBLE ALARM INDICATED AT FIRE ALARM CONTROL PANEL AND REMOTE ANNUNCIATOR PANEL (IF PROVIDED). 2) TROUBLE SIGNAL TRANSMITTED TO CENTRAL STATION. 3) MANUAL ACKNOWLEDGE FUNCTION AT FIRE ALARM CONTROL PANEL SILENCES AUDIBLE TROUBLE ALARM; VISIBLE ALARM IS DISPLAYED UNTIL INITIATING FAILURE OR CIRCUIT TROUBLE IS CLEARED. SUPERVISORY SEQUENCE OF OPERATION: THE ACTIVATION OF ANY SPRINKLER VALVE TAMPER SWITCH OR DUCT— MOUNTED SMOKE DETECTOR PLACES SYSTEM IN SUPERVISORY MODE, WHICH CAUSES THE FOLLOWING SYSTEM OPERATIONS: 1) VISIBLE AND AUDIBLE SUPERVISORY ALARM INDICATED BY ADDRESS AT FIRE ALARM CONTROL PANEL AND REMOTE ANNUNCIATOR PANEL (IF PROVIDED). 2) SUPERVISORY SIGNAL TRANSMITTED TO CENTRAL STATION. 3) DUCT — MOUNTED SMOKE DETECTORS SHALL SHUTDOWN THEIR RESPECTIVE UNIT UPON DETECTION OF SMOKE AND REMAIN DOWN UNTIL MANUALLY RESET. 4) MANUAL ACKNOWLEDGE FUNCTION AT FIRE ALARM CONTROL PANEL AND REMOTE ANNUNCIATOR PANEL SILENCES AUDIBLE SUPERVISORY ALARM; VISIBLE ALARM IS DISPLAYED UNTIL DEVICE IS RETURNED TO ITS NORMAL POSITION /SUPERVISORY CONDITION IS CLEARED. ALARM SEQUENCE OF OPERATION: ACTUATION OF AN ALARM INITIATING DEVICE PLACES SYSTEM IN ALARM MODE, WHICH CAUSES THE FOLLOWING SYSTEM OPERATIONS. 1) AUDIBLE NOTIFICATION APPLIANCES SHALL SOUND UNTIL SILENCED BY THE ALARM SILENCE SWITCH AT THE CONTROL PANEL. 2) ALL VISIBLE ALARM NOTIFICATION APPLIANCES SHALL DISPLAY A CONTINUOUS SYNCHRONIZED PATTERN UNTIL RESET BY THE ALARM RESET SWITCH. 3) ALARM SIGNAL TRANSMITTED TO CENTRAL STATION. 4) ALL AIR — HANDLING SYSTEMS THAT ARE MONITORED SHALL SHUTDOWN AND REMAIN DOWN UNTIL THE FIRE ALARM CONTROL PANEL IS RESET. 5) THE ALARM LED SHALL FLASH ON THE CONTROL PANEL AND REMOTE ANNUNCIATOR PANEL UNTIL THE ALARM HAS BEEN ACKNOWLEDGED AT THE CONTROL PANEL /REMOTE ANNUNCIATOR PANEL. ONCE ACKNOWLEDGED, THIS SAME LED SHALL LATCH ON AND THE CUSTOM LABEL FOR THE ADDRESS IN ALARM SHALL BE DISPLAYED ON THE ALPHANUMERIC LCD READOUT. A SUBSEQUENT ALARM RECEIVED FROM ANOTHER ADDRESS AFTER ACKNOWLEDGED SHALL FLASH THE ALARM LED ON THE CONTROL PANEL SHOWING THE NEW ALARM INFORMATION. 6) A PULSING ALARM TONE SHALL OCCUR WITHIN THE CONTROL PANEL UNTIL ACKNOWLEDGED. 16C 2 -4 INITIATING DEVICES DUCT MOUNTED SMOKE DETECTOR: PHOTOELECTRIC DETECTOR ALONG WITH A STANDARD, RELAY OR ISOLATOR DETECTOR MOUNTING BASE. PROVIDE FOR VARIATIONS IN DUCT AIR VELOCITY BETWEEN 300 AND 4000 FEET PER MINUTE. PROTECT THE MEASURING CHAMBER FROM DAMAGE AND INSECTS. PROVIDE AN AIR EXHAUST TUBE AND AN AIR SAMPLING INLET TUBE THAT EXTENDS INTO THE DUCT AIR STREAM UP TO TEN FEET. PROVIDE DRILLING TEMPLATES AND GASKETS TO FACILITATE LOCATING AND MOUNTING THE HOUSING. PROVIDE REMOTE ALARM LEDS AND REMOTE TEST STATIONS AS SHOWN ON THE PLANS. 16C 2-5 NOTIFICATION APPLIANCES VISIBLE ALARM NOTIFICATION APPLIANCES (STROBES): STROBES SHALL BE XENON OR EQUIVALENT, UNFILTERED OR CLEAR FILTERED WHITE LIGHT, A MINIMUM INTENSITY OF 15/75 CANDELA AND AS INDICATED ON DRAWINGS, FLASH RATE RANGE FROM 1 TO 3 HZ, A MAXIMUM PULSE DURATION OF 0.2 SEC WITH A MAXIMUM DUTY CYCLE OF 40 %. STROBE SHALL MEET ALL REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT (MINIMUM 75 CD AS TESTED PER UL 1971). AUDIBLE/VISIBLE ALARM NOTIFICATION APPLIANCES (HORN /STROBES): COMBINATION UNITS SHALL PROVIDE A COMMON ENCLOSURE FOR THE FIRE ALARM AUDIBLE AND VISIBLE ALARM APPLIANCES AND BE UL LISTED FOR ITS PURPOSE. MINIMUM AUDIBLE LEVEL AND STROBE INTENSITY SHALL MEET ALL REQUIREMENTS FOR SEPARATE APPLIANCES. 16C 2 -6 AUXILIARY DEVICES CONTROL RELAY MODULE: PROVIDE INTELLIGENT CONTROL RELAY MODULES. THE CONTROL RELAY MODULE SHALL PROVIDE ONE FORM "C" DRY RELAY CONTACT RATED AT 2 AMPS 24 VDC TO CONTROL EXTERNAL APPLIANCES OR EQUIPMENT SHUTDOWN. THE CONTROL RELAY SHALL BE RATED FOR PILOT DUTY AND RELEASING SYSTEMS. THE POSITION OF THE RELAY CONTACT SHALL BE CONFIRMED BY THE SYSTEM FIRMWARE. 160 2 -7 FIRE ALARM WIRE AND CABLE FIRE ALARM POWER BRANCH CIRCUITS: BUILDING WIRE AS SPECIFIED IN DIVISION 16. SIGNALING LINE, INITIATING DEVICE AND NOTIFICATION APPLIANCE CIRCUITS: POWER LIMITED FIRE— PROTECTIVE SIGNALING CABLE, SOLID COPPER CONDUCTOR, 300 VOLTS INSULATION, SUITABLE FOR TEMPERATURE, CONDITIONS AND LOCATION INSTALLED. MINIMUM WIRE SIZE FOR INITIATING DEVICE CIRCUITS, CONTROL CIRCUITS AND NOTIFICATION APPUANCE CIRCUITS SHALL BE DETERMINED BY CALCULATIONS AND MANUFACTURER'S REQUIREMENTS OR RECOMMENDATIONS. WIRE AND CABLE SHALL BE TWISTED AND SHIELDED IF RECOMMENDED BY THE SYSTEM MANUFACTURER. INITIATING, NOTIFICATION, AND CONTROL CIRCUITS SHALL BE SIZED BASED ON 20% ADDITIONAL POWER CONSUMING DEVICES. THE CONDUCTORS SHALL MEET THE REQUIREMENTS OF NEC ARTICLE 760. THE TYPE OF CABLE CHOSEN SHOULD BE BASED ON FIRE ALARM SYSTEM REQUIREMENTS, SPECIFICATION REQUIREMENTS AND APPLICABLE CODE REQUIREMENTS. CONSIDERATION SHOULD ALSO BE GIVEN TO THE LENGTH OF CABLE RUNS AND POTENTIAL INTERFERENCE. ALL WIRING PROVIDED ON THIS PROJECT SHALL BE UL USTED FOR THE INTENDED USE. ALL WIRING INCLUDING WIRING TO EXISTING MODIFIED DEVICES AND APPLIANCES SHALL BE NEW. 16C 3 EXECUTION 16C 3 -1 GENERAL THE CONTRACTOR SHALL INSTALL, PROGRAM AND TEST ALL NEW EQUIPMENT IDENTIFIED IN THIS CONTRACT AND REVISE EXISTING EQUIPMENT AS NOTED. THE INSTALLATION SUPERVISOR SHALL BE ON THE JOB SITE DURING THE ENTIRE INSTALLATION. THE INSTALLATION SUPERVISOR SHALL MAINTAIN MARKED UP COPIES OF THE DRAWINGS AT THE JOB SITE SHOWING AS —BUILT CONDITIONS. THESE DRAWINGS SHALL BE UPDATED DAILY AND AVAILABLE FOR OWNER REVIEW. THE CONTRACTOR SHALL PROVIDE ALL REQUIRED CONDUIT AND ALL ASSOCIATED HARDWARE, AND SHALL INSTALL (PULL), CONNECT, AND TEST ALL CABLE FOR A COMPLETE FIRE ALARM SYSTEM. ALL WIRING SHALL BE INSTALLED IN ACCORDANCE WITH THE GUIDELINES OF THESE SPECIFICATIONS AND DOCUMENTS AS WELL AS THE NFPA CODES AND STANDARDS LISTED IN THESE SPECIFICATIONS. 16C 3 -2 INSTALLATION MINIMUM ALLOWABLE CONDUIT SIZE SHALL BE 3/4 INCH. THE CONDUIT SHALL BE SIZED SO THAT CONDUIT FILL DOES NOT EXCEED 75% OF NFPA 70 MAXIMUM FILL REQUIREMENTS. CABLES IN VERTICAL RISERS SHALL NOT EXCEED 50% OF NFPA 70 MAXIMUM FILL REQUIREMENTS. CONDUIT INSTALLATION SHALL BE AS REQUIRED BY THE CONTRACTOR'S LAYOUT AND AS DESCRIBED IN THESE SPECIFICATIONS. ALL CONDUIT FIELD ROUTING SHALL BE ACCEPTABLE TO THE OWNER. ROUTING NOT ACCEPTABLE SHALL BE REROUTED AND REPLACED WITHOUT EXPENSE TO THE OWNER. ALL WIRE, CABLE, CONDUIT AND RACEWAYS SHALL BE CONCEALED IN WALLS, CEIUNG SPACES, ELECTRICAL SHAFTS OR CLOSETS IN FINISHED AREAS EXCEPT AS SPECIFICALLY NOTED OTHERWISE. CONDUIT AND RACEWAYS MAY BE EXPOSED IN UNFINISHED AREAS OR WHERE SPECIFICALLY APPROVED BY THE OWNER. EXCEPT AS OTHERWISE SPECIFIED OR INDICATED ON THE DRAWINGS, ALL CONDUIT SHALL BE INSTALLED PARALLEL OR PERPENDICULAR TO DOMINANT SURFACES WITH RIGHT ANGLE TURNS MADE OF SYMMETRICAL BENDS OR FITTINGS. EXCEPT WHERE PREVENTED BY THE LOCATION OF OTHER WORK, A SINGLE CONDUIT OR A CONDUIT GROUP SHALL BE CENTERED ON STRUCTURAL MEMBERS. CONDUIT SHALL BE LOCATED AT LEAST SIX INCHES FROM HOT WATER OR STEAM PIPES, AND FROM OTHER HOT SURFACES. CONDUIT SHALL NOT BLOCK ACCESS TO ANY EXISTING EQUIPMENT OR FIXTURES. ALL CONDUITS AND JUNCTION BOXES SHALL BE LABELED AS SPECIFIED IN DIVISION 16 (RED). ALL WIRING SHALL BE TERMINATED AT DEVICES OR PANELS USING TERMINAL CONNECTORS FOR SCREW TYPE TERMINALS. ALL TERMINAL CONNECTORS FOR CONDUCTORS SHALL BE PRE — INSULATED RING TYPE OR PRE — INSULATED SPADE TYPE. PRE — INSULATED TERMINAL CONNECTORS SHALL INCLUDE A VINYL SLEEVE, COLOR CODED TO INDICATE CONDUCTOR SIZE. PRE — INSULATED TERMINAL CONNECTORS SHALL INCLUDE A METALLIC SUPPORT SLEEVE BONDED TO THE VINYL — INSULATING SLEEVE AND DESIGNED TO GRIP THE CONDUCTOR INSULATION. MOUNT END—OF—LINE DEVICE IN BOX WITH LAST DEVICE OR SEPARATE BOX ADJACENT TO LAST DEVICE IN CIRCUIT FOR CONVENTIONAL HARDWIRED CLASS B INITIATING AND NOTIFICATION APPLIANCE CIRCUITS. CONDUIT SHALL BE SECURELY FASTENED TO ALL BOXES AND CABINETS. THREADS ON METALLIC CONDUIT SHALL PROJECT THROUGH THE WALL OF THE BOX TO ALLOW THE BUSHING TO BUTT AGAINST THE END OF THE CONDUIT. THE LOCKNUTS BOTH INSIDE AND OUTSIDE SHALL THEN BE TIGHTENED SUFFICIENTLY TO BOND THE CONDUIT SECURELY TO THE BOX. CONDUIT SHALL ENTER CABINETS FROM THE BOTTOM AND SIDES ONLY. INSTALL WALL MOUNTED VISIBLE AND AUDIBLE /VISIBLE NOTIFICATION APPLIANCES WITH VISIBLE ELEMENT (STROBE) BETWEEN SO INCHES AND 96 INCHES ABOVE FINISHED FLOOR UNLESS NOTED OTHERWISE ON DRAWINGS. INSTALL WALL MOUNTED AUDIBLE DEVICES WITH THE TOP OF THE DEVICE AT LEAST 90 INCHES ABOVE FINISHED FLOOR OR 6 INCHES BELOW THE CEILING, WHICHEVER IS LOWER, UNLESS NOTED OTHERWISE ON DRAWINGS. IF COMBINATION DEVICES ARE INSTALLED, THEY SHALL BE INSTALLED PER THE VISIBLE SIGNAL DEVICE REQUIREMENTS. MAKE CONDUIT AND WIRING CONNECTIONS TO EQUIPMENT PROVIDED BY OTHERS LISTED IN SECTION 1.1.E. PROVIDE STROBE SYNCHRONIZATION AS REQUIRED PER NFPA 72. 16C 3 -3 FIELD QUALITY CONTROL SYSTEMS SHALL BE CHECKED AND TESTED IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED BY THE MANUFACTURER TO INSURE THAT THE SYSTEM FUNCTIONS AS REQUIRED AND IS FREE OF GROUNDS, OPENS, AND SHORTS. EACH DEVICE SHALL BE TESTED. SMOKE DETECTORS SHALL BE TESTED WITH PRODUCTS OF COMBUSTION. UPON COMPLETION OF THE SYSTEM INSTALLATION AND BEFORE THE DATE OF FINAL ACCEPTANCE, A FACTORY -- TRAINED TECHNICIAN SHALL PERFORM ALL NECESSARY TESTS AND ADJUSTMENTS AND SHALL THEN FILE A LETTER OF CERTIFICATION AND A CERTIFICATE OF COMPLETION (NFPA 72) WITH THE OWNER INDICATING THAT THE SYSTEM FUNCTIONS AND CONFORMS TO THE FIRE ALARM SYSTEM SPECIFICATIONS. TEST IN ACCORDANCE WITH NFPA 72 AND LOCAL FIRE DEPARTMENT REQUIREMENTS. 16C 3 -4 MANUFACTURER'S FIELD SERVICES INCLUDE SERVICES OF FACTORY TRAINED AND CERTIFIED TECHNICIAN TO SUPERVISE INSTALLATION, ADJUSTMENTS, FINAL CONNECTIONS, AND SYSTEM TESTING AS PERFORMED BY THE FIRE ALARM CONTRACTOR'S FACTORY— TRAINED TECHNICIANS. THE EQUIPMENT SUPPLIER'S FACTORY TRAINED TECHNICIAN SHALL TRAIN THE OWNER'S PERSONNEL IN THE PROPER USE AND MAINTENANCE OF THE SYSTEM. TRAINING SESSIONS SHALL BE CONDUCTED AS NEEDED, NOT TO EXCEED A TOTAL OF 2 SESSIONS, WITH EACH SESSION LASTING A MAXIMUM OF 4 HOURS EACH. 16C 3 -5 ACCEPTANCE TESTING UPON COMPLETION OF THE SYSTEM INSTALLATION, A FACTORY — TRAINED TECHNICIAN SHALL PERFORM ALL NECESSARY TESTS AND ADJUSTMENTS IN THE PRESENCE OF THE OWNER'S DESIGNATED PERSONNEL. END OF SECTION 16C 011 HnVE FEB-82008 PERMIT CENTER HENDERSON ENGINEERS= 10370 RICHMOND AVENUE, SUITE 370 HOUSTON, TX 77042 TEL 713 783 7707 FAX 713 783 7797 www.hei- eng,com 0750001294 RJS 1MH SIM A CE ag LLI o IMM Z 1— ILI w I- I 0 P 11/0$/0 ISSUED / REVISED DATE HEALTH DEPT SUBMITTAL 12.17.07 98% OWNER REVIEW 01.03.08 HEALTH DEPT RVSNS 01.11.08 ISSUED FOR PERMIT 01.25.08 FIRE ALARM SPECIFICATIONS E -4.1 Use' LPA (Wisf) Use' LPA` (W /sf) Automotive facility 0.9 Office buildings, office/administrative areas in Facilities of other use types (Including but not limited to schools, hospitais, Institutions. museums. banks, churches) 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 _ Courthouse 12 Police and fire stations" 1.0 Cafeterias, fast food estabfishments restaurants/bars 1.3 Post office 1.1 Dormitory 1.0 Retail retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia', assembly spaces" 1.0 Theater. motion picture 1.2 Health care clinic 1.0 1.2 Theater, performing arts Transportation 1.6 1.0 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies Hot t /motel 1.0 Warehouses", storage areas 0.5 Hotel banquet /conference/exhibltion hall''' 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified 'laboratory' shall meet office and other appropriate categories) 1.8 Parking garages 02 laundries 1.2 Schedule with type and features, indicate location no Libraries 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Project Info Prof Addres cede,. cb lacier - 8outhcenter Mall Date 1/24/2008 633 Soathousiter, Suite 1020 For Building Department Use Seattle, WA 98155 Name: Appl. Name Appl. Phone 240.0 Project Description New ❑ Addition ❑ Alteration 0 Plans Included Indicate controls (Sections 1513) Including commissioning requirements on plans. Compliance Option C) Lighting Power Allowance 0 Systems Analysis Building Grounds (luminaires 5 100 Watts) ❑ Efficacy e 69 lumens/W ❑ ControAed by motion Sensor 151 Exemption (list) 88.0 101 Alteration Exceptions (check appropriate box - sec. 1132.3) . • No changes are being made to the lighting ❑ Less than 60% of the fixtures new. installed wattage not increased, & space use not changed. Project Info Project Address Godi1ra Chncolati.er - Southcenter Mall Date 1/24/2008 633 Southcenter, Stcte 1020 For Building Department Use Seattle, to 98180 Applicant Name: Applicant Address: Applicant Phone; 240.0 Project Description ❑ Plans included requirements. r New Building ❑ Addition 12 Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (Sea Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not Increased, & space use not changed. Location (floor /room no.) Fixture Description Number of Fixtures Watts! Fixture Watts Proposed 101 Type 32 - Sesd- Recessed Adjustable Fixture 6 40.0 240.0 101 Type SA - 6" Square Adjustable Fixture 4 44.0 176.0 101 Type SD - 6" Square Downlight 2 44.0 88.0 101 Type PA -- Pendant - Exempt per Table 15 - 1, Footnote 10 8 no 101 Type 52A - Semi.- Recessed adjustable Fixture 2 44.0 88.0 102 Type SR - 4 T Linear Channel Fixture -- 5 58,0 290.0 103 Type FC - Fan/Light Combo 1 60,0 50_0 101 Type S2 - Exempt per 1512,1 - Faad Prep Area 4 1513.4 Displaylexhib /special 101 Type 52 - Exempt per Table 15 -1, Footnote 10 4 1513.5 Exterior shut-off Schedule with type and features, indicate location no (a) timer wibadcup Indicate location xo exterior lug no Prescriptive Spaces O ccupancy: 0 Warehouses, storage areas or aircraft storage hangers Q Other Qualification Checklist Note: if occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly ughli°g Fixtures: (Section 1521) Sales Area 101 4 Check if 95% or more of fixtures comply with 1.2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T -1, T -2, T-4, T-5, T-8 lamps, and d) hard -wired eleo- tonic dimming bal lasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. indicate these spaces on plans. If not qualified, do LPA Calculations. Tradable Locations Description Allowed Watts per ft or per If Area (ft perimeter (If) or# of items Allowed Watts x if or x If) Sales Area 101 Retail Sales Area 1.50 645.0 967.5 Stockroom 102 Stockroom attached to main Sales Floor 0.50 162.0 81.0 Restroom 103 aestroem 0.80 56.0 44.8 Non - Tradable Locations Description Allowed Watts per ft or per if Area (ft2), perimeter (10 or # of items Allowed Watts x ft2 (or x If) Sales Area 101 Retail Sales Area 1.50 645.0 967.5 Stockroom 102 Stockroom attached to main Sales Floor 0.50 162.0 81.0 Restroom 103 aestroem 0.80 56.0 44.8 Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Sales Area 101 Retail Sales Area 1.50 645.0 967.5 Stockroom 102 Stockroom attached to main Sales Floor 0.50 162.0 81.0 Restroom 103 aestroem 0.80 56.0 44.8 Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Sales Area 101 Retail Sales Area 1.50 645.0 967.5 Stockroom 102 Stockroom attached to main Sales Floor 0.50 162.0 81.0 Restroom 103 aestroem 0.80 56.0 44.8 Location (floor /room no.) Occupancy Description Allowed Watts per ft2 .. Area in ft2 Allowed x Area Sales Area 101 Retail Sales Area 1.50 645.0 967.5 Stockroom 102 Stockroom attached to main Sales Floor 0.50 162.0 81.0 Restroom 103 aestroem 0.80 56.0 44.8 Lighting; Motor, and•Transformer. Permit Plans Checklist; 2006 Washington State Narossidedtal Energy Code Compliance Forms - LTG -CHK Revised July 2007 Project Address Cod a Chocolatier - Southcenter Mall Date 1/24/2008 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) - Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control/access Schedule with type, indicate locations s -2.0 yes 1513.2 Area controls Maximum Limit per switch E -2.0 no 1513.3 Daylight zone control Schedule with type and features, Indicate locations no vertical glazing Indicate vertical glazing on plans eto daylighting no overhead glazing Indicate overhead glazing on plans No overhead glazing yes 1513.4 Displaylexhib /special Indicate separate controls E -2 1513.5 Exterior shut-off Schedule with type and features, indicate location no (a) timer wibadcup Indicate location xo exterior lug no (b) photocell. Indicate location NO exterior lug 1513.6 Inter. auto shut -off Indicate location no 1513.6.1 (a) occup. sensors Schedule with type and locations Controlled by contactor and switches yes 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans E -2 Contactor Cl no 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes 1514 Max. watts I indicate watts for each exit sign a -1.0 LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with future types, lamps, ballasts. watts per fixture Attached no 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, t lamps, ballasts, watts per fixture No exterior ltg MOTORS (Section 1511) no 1511 Elec motor efficiency MECH -MOT or Equipment Schedule with hp, rpm, efficiency No motors over lbp TRANSFORMERS (Section 1540) yes 1540 Transformers Indicate size and efficiency E- 2.1,E - T51 4.0 1 2 3 4 5 6 7 8 9 10 Interior Lighting Summary LTG -INT 200e Washington State Nonresidential Energy Code Coinprianca Farms Maximum Allowed Lighting Wattage Proposed Lighting Wattage 2006 Washington State Nonresidential Energy Code Compliance Form ram Table 15.1 (over) - document all exceptions on form LTG -LPA otal Proposed Watts may not exceed Total Allowed Watts for Interior Total Allowed Watts Total Proposed Watts Revised July 2007 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if inducted). For track lighting, fist the length of the Eradk (in Feet) in addition to the fixture, lamp. and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only the default table in the NREC Technical Reference Manual may also be used. For trade lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. 1093.3 942.0 Interior. Lighting Summary (back) LTG -iNT 2006 Washington Slate Nonresidential Energy Code Compliance Forms TABLE 15-1 Unit LightingPower Allowance (LPA ootnotes for Table 2006 Washington State Nonresidential Energy Code Compliance Form Revised Jdy 2007 1) In cases in which a general use and a specific use are fisted, the specific use shalt apply. In cases in which a use is not mentioned specifically. the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet, 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be Increased by two percent per foot of ceiling height above nine feet, 6) Reserved. 7) For conference rooms and offices less than 150ft with full height partitions, a Unit Lighting Power Allowance of 1.10 w/ft may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 Wlft 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w/ft of merchandise display luminaires are exempt provided that they comply with Ali three of the following: a) located on ceiling - mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge tamps. This additional lighting power is allowed only if the lighting Is actually installed. 11) Provided that a floor plan. indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (ar ees side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. Exterior Lighting. Summary 2006 Washington State Nonresidential Energy Cade CompSance Farms Tradable Maximum Allowed Li tin Wattage Tradable Proposed Lighting Wattage Total Proposed Watts may not exceed Total Allowed Watts for Exterior Non - Tradable Maximum Allowed Lighting Wattage Non - Tradable Proposed Lighting Wattage 2006 Washington State Nonresidential Energy Code Compliance Form Proposed Watts may not exceed Allowed Watts for Category 2006 Washington State Nonresidential EnergyCgde Compliance Form If "no" is circled for any question, provide explanation: Revised July 2007 Total Allowed Watts Use mfgr listed maximum input wattage. For fixtures with hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. Total Proposed Watts Dos -ov FEB -8 2008 PERMIT GENTEh HENDERSGN ENGINEERS"" =_ 10370 RICHMOND AVENUE, SUffE 370 HOUSTON, TX 77042 TEL 713 783 7707 FAX 713 783 7797 www.hei eng.com 0750001294 RJS JMH SIM 12/08/ 08 V co 15 Zi; a) 0-) LO N 0 IzT 0 0 U) ISSUED / REVISED DATE HEALTH DEPT SUBMITTAL 98% OWNER REVIEW HEALTH DEPT RVSNS ISSUED FOR PERMIT E -5.0 12.17.07 01.03.08 01.11.08 01.25.08 ELECTRICAL ENERGY FORMS