HomeMy WebLinkAboutPermit D08-097 - GENERAL ELECTRIC AIRCRAFT ENGINES - STORAGE RACKSGE AIRCRAFT ENGINES
12600 INTERURBAN AV S
D08-097
Parcel No.: 0004800003
Address: 12600 INTERURBAN AV S TUKW
Suite No:
Tenant:
Name: GENERAL ELECTRIC AIRCRAFT ENGINES
Address: 12600 INTERURBAN AV S SUITE B , TUKWILA WA
Owner:
Name: C/O EPROPERTYTAX INC
Address: DEPT #207 , PO BOX 4900 85261
Phone:
Cityltf Tukwila
Contact Person:
Name: MIKE SORENSON
Address: 1100 SW 7TH ST , RENTON WA 98057
Phone: 206- 818 -4488
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Contractor:
Name: NORTH WEST HANDLING SYSTEMS INC
Address: 1100 S.W. 7TH STEET , RENTON, WA 98055
Phone: 206 255 -0500
Contractor License No: NORTHWH275JF
DEVELOPMENT PERMIT
DESCRIPTION OF WORK:
INSTALLATION OF SHELVING FOR STORAGE OF AIRCRAFT ENGINE PARTS AND SUPPLIES
doc: IBC -10/06
* * continued on next page **
Permit Number: D08 - 097
Issue Date: 02/28/2008
Permit Expires On: 08/26/2008
Expiration Date: 10/09/2009
Value of Construction: $0.00 Fees Collected: $137.66
Type of Fire Protection: SPRINKLERS International Building Code Edition: 2006
Type of Construction: Occupancy per IBC: 0024
D08 -097 Printed: 02 -28 -2008
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone:
Hauling: N Start Time: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension: Private:
Storm Drainage:
Street Use: Profit: N
Water Main Extension: Private:
Water Meter: N
Permit Center Authorized Signature:
I hereby certify that I have read and
City diTukwila •
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
governing this work will be complied kitl� whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance o . I am authorized to sign and obtain this development permit.
Signature:
doc: IBC -10/06
Print Name: /L�C �C�U�'��SGrt
Permit Number: D08 - 097
Issue Date: 02/28/2008
Permit Expires On: 08/26/2008
Date:
Public:
Non - Profit: N
Public:
Date:
ed this permit and know the same to be true and correct. All provisions of law and ordinances
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
D08 -097 Printed: 02 -28 -2008
Parcel No.: 0004800003
Address:
Suite No:
Tenant:
doc: Cond -10/06
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
12600 INTERURBAN AV S TUICW
GENERAL ELECTRIC AIRCRAFT ENGINES
1: ** *BUILDING DEPARTMENT CONDITIONS * **
9 ** *FIRE DEPARTMENT CONDITIONS * **
PERMIT CONDITIONS
Permit Number:
Status:
Applied Date:
Issue Date:
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Euilding Official.
3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
4: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
5: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet
in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and
calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State
of Washington.
6: Manufacturers installation instructions shall be available on the job site at the time of inspection.
D08 -097
ISSUED
02/20/2008
02/28/2008
7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
11: Maintain coverage and operability of portable fire extinguishers, sprinkler systems and fire alarm systems during
demolition and construction.
12: High -piled combustible storage is combustible materials in closely packed piles more than 12 feet in height or
combustible materials on pallets or in racks more than 12 feet in height. For certain special- hazard commodities such
as rubber tires, plastics, some flammable liquids, idle pallets, etc., the critical pile height may be as low as 6
feet. (IFC 2302)
13: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following
methods is required for steel building columns located within racks: (a) one -hour fire proofing, (b) sidewall sprinkler
at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire
Prevention Bureau. (NFPA 13)
D08 -097 Printed: 02 -28 -2008
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
14: Nominal 6" transverse flue spaces between loads and at rack uprights shall be maintained in single row, double row, and
multiple row racks. Random variations in the width of flue spaces or in their vertical alignment shall be permitted.
(NFPA 13- 12.3.1.13)
13: Pallets shall be stored no higher than 6 feet (1.8 m). Each pallet pile of no more than four stacks shall be separated
from other pallet piles by at least 8 feet (1.4 m) of clear space or 25 feet (7.6 m) of commodity. Idle wood pallets
shall not be stored in racks. (NFPA 13- 12.1.9.1.2)
13: Aisles in sprinklered buildings shall be a minimum of 44 inches (1118 mm) wide. Aisles shall be a minimum of 96 inches
(2438 mm) wide in high -piled storage areas exceeding 2,500 square feet (232 m in area, that area accessible to the
public and designated to contain high- hazard commodities. Aisles shall be a minimum of 96 inches (2438 mm) wide in
areas accessible to the public where mechanical stocking methods are used. (IFC 2306.9.1.1)
17: The required aisle width shall extend from floor to ceiling. Rack structural supports and catwalks are allowed to cross
asles at a minimum height of 6 feet 8 inches (2032 mm) above the finished floor level, provided that such supports do
not interfere with fire department hose stream trajectory. (IFC 2306.9.2)
13: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18
inches below sprinkler head deflectors in sprinidered areas of buildings. (IFC 315.2.1)
19: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is
calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A,
20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1)
20: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or
brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation
instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so
that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross
weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the
floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4
inches (102 mm). (IFC 906.7 and IFC 906.9)
21: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot
be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6)
22: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available
for use. These locations shall be along normal paths of travel, unless the fire code official determines that the
hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5)
23: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating
and/or adding sprinkler heads. (IFC 901.4)
24: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and
approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler
systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk
Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to
the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050)
25: All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to the Tukwila
ire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80)
doc: Cond -10/06
D08 -097 Printed: 02 -28 -2008
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
26: Aisles leading to required exits shall be provided from all portions of the building and the required width of the
aisles shall be unobstructed. (IFC 1013.4)
27: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and
#2051)
28: To schedule all construction fire - related inspections send an e -mail to fireinsprequest @ci.tukwila.wa.us. Include your
name, telephone number, permit number, project name and address and type of inspection requested.
29: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
30: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
dac: Cond -10/06
* *continued on next page **
D08 -097 Printed: 02 -28 -2008
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the performance of work.
dac: Cond -10/06
Date: ' c/�4
D08 -097 Printed: 02 -28 -2008
Property Owners Name:
Mailing Address:
Name: Al (
Company Name:
Mailing Address:
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
htlh ivbvbr. ci. tuktvzia. us
Company Name: <k S i
Building Permit No.
Mechanical Permit No.
Plumbing /Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
660-- � U ie King Co Assessor's Tax No.: 06 �i UQ 00 i 1 '
Site Address: (0 �/1 . 5tiIz S.
G
Tenant Name: ;narrt.( tf-2G ' f'C f 1ccrac- yirt2 ,S
Mailing Address: /100 S-U/• ' 7 5
E -Mail Address: 01 So(`en,50/I & n LA) K
Contact Person:
E -M. i dress:
Contact Person: 6 c &A. at vl
E -Mail Address:
Q:\ApplicationsWorms- Applications On Line \3 -2006 - Permit Application.doc
Revised. 9 -2006
bh
Suite Number: Floor:
City
Company Name: Po r +1. LU2- s t ( n `L /! / y � Y /
Mailing Address: / /1)D .c W 71 S T �t'✓ 4,1
City
New Tenant: M Yes
State
..No
Zip
CONTACT PERSON — who do we contact when your permit is ready to be issued
Day Telephone: t 6 k- '7 e F te
City State Zip
Fax Number: 1- S - c3)' ' 6 of 4 ( 6
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
v, rate
L Zip
Contact Person: l /�l -i Day Telephone: o)6r �c &tg-- 4 R
E -Mail Address: t/VI £c't`eri cc" 0 h W S tr•^^
Contractor Registration Number: / . cr444 +A.J k ;").:75 TF
Fax Number: (/p,S ° a' 6`' !{L,
Expiration Date: /0 /0 C c/ OC >cj
ARCHITECT OF RECORD — All plans must be wet stamped, by Architect of Record
State
Zip
City
Day Telephone:
Fax Number:
ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record
Mailing Address: s' t c� W. . ( v /:e C/4 7l ,y
City State Zip
Day Telephone: ', /g y1 3g
Fax Number: BY ?YO . 3 "-3
Page 1 of 6
BUILDING PERMIT INFORMATION — 206- 431 -3670
Valuation of Project (contractor's bid price): $ / 'k G 0 Existin Building Valuation: $
Sco r - of Work (please provide detailed information):
6 I�
Gzt.AINZI r/ t r r t /
5 ell'Me .� Src t (o rG 4 tC4- ; �' -��.2(��tC -r-�t
/ sue vi
Will there be new rack storage? Yes ❑ No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
Q:\Applications\Forms- Applications On Line \3 -2006 - Permit Application :dos
Revised: 9 -2006
bh
P alk
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 incheV
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
.... Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System – For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
Page 2 of 6
Existing
interior Remodel
Addition
Existing
Stricture
to
1Vew
Type of
Construction per
BC
Type of
Occupancy per
IBC
1' Floor
3 ��—
3 5710
2"d Floor
3 Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
BUILDING PERMIT INFORMATION — 206- 431 -3670
Valuation of Project (contractor's bid price): $ / 'k G 0 Existin Building Valuation: $
Sco r - of Work (please provide detailed information):
6 I�
Gzt.AINZI r/ t r r t /
5 ell'Me .� Src t (o rG 4 tC4- ; �' -��.2(��tC -r-�t
/ sue vi
Will there be new rack storage? Yes ❑ No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
Q:\Applications\Forms- Applications On Line \3 -2006 - Permit Application :dos
Revised: 9 -2006
bh
P alk
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 incheV
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
.... Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System – For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
Page 2 of 6
•
PERMIT APPLICATION NOTES —:Applic , permits iu this application
•
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Signature:
Print Name:
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Mailing Address: I 1 00
Date Application Accepted:
•
7
og
Q:\Applications\Fonns- Applications On Line U-2006 - Permit Application.doc
Revised' 9 -2006
bh
Date: c / /��0cc
Day Telephone: 76 � (cS ' ` WSW
<"zv..Jc.,r. w4-- 98 S 7
City State Zip
Date Application Expires:
Staff Initials:
w I
Page 6 of 6
Parcel No.: 0004800003 Permit Number: D08 -097
Address: 12600 INTERURBAN AV S TUKW Status: PENDING
Suite No: Applied Date: 02/20/2008
Applicant: GENERAL ELECTRIC AIRCRAFT ENGINES Issue Date:
Receipt No.: R08 - 00476 Payment Amount: $137.66
Iritials: WER Payment Date: 02/20/2008 10:10 AM
User ID: 1655 Balance: $0.00
Payee: MICHAEL SORENSON
TRANSACTION LIST:
Type Method Description Amount
Payment Check 7074 137.66
ACCOUNT ITEM LIST:
Description
BUILDING - NONRES
PLAN CHECK - NONRES
STATE BUILDING SURCHARGE
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http://www.ci.tukwila.wa.us
Account Code Current Pmts
000/322.100
000/345.830
000/386.904
RECEIPT
80.70
52.46
4.50
Total: $137.66
8859 02/20 9710 TOTAL 137.66
doc: Receipt -06 Printed: 02 -20 -2008
COMMENTS:
ype of Inspe do
�'A�..4 u I
Al
9
p.0 p(Avi .
C 4P i AT r44 e
Ay"! o,./e6(
p
Date Wanted:
3 -
p.m.
Requester:
p(JMm
/
p(e-I .
Project: � /�
�frii• -: rL a '
feAFirt- ,A
ype of Inspe do
�'A�..4 u I
Al
Address:
I2(,00 T,n7.JJi A/(L J
Date Called:
.3L... l
I
Special Instructions: \
h .t Q f
3a
p
Date Wanted:
3 -
p.m.
Requester:
Phone No:
4tl
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
IDo 8 - D9'/
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION IfZ
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3
Approved per applicable codes. LJ Corrections required prior to approval.
Ins pectoC
Date:
11 ' J `J
❑ $58.00 REINSPECTION FEE RE UIRED. Prior o inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection.
Receipt No.:
Date:
Project: (E t) it e Q. A Pi Ems+ G 1 E.
Ty a of Inspection:
Address: 12 (c ci
Suite #: (I0
A S
Contact Person:
STENIe. — as% LL. — MNGL
Special Instructions:
Permits: 00.4i
Phone No.:
ZOb- 2L — Zp`
Needs Shift Inspection:
S i rinkl ers:
Fire Alarm:
Hood & Duct: j C
Monitor:
Pre -Fire: I 1.4 L.
Permits: 00.4i
Occupancy Type: 5- 2
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA FIRE DEPARTMENT
444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407
A pproved per applicable codes:
COMMENTS:
Rd2.k_ -- 01 ?-
.cAt 1.444 L L f-t Olt - it) Spsa 1.. rf (i`12. .A )Qg
Inspector: (a, { s
Date: ; jlz/a�
Hrs.:
$80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
ity of Tukwila Finance Department. Call to schedule a reinspection. •
Word /Inspection Record Form.Doc 1/13/06
P
- vq
PERMIT NUMBERS
Corrections required prior to approval:
T.F.D.
Form F.P. 113
Prnu�`'. it No„
FILE COPY
NORTHWEST
H A N D L I N G S Y S T E M S , I N C.
The Material Handling Experts
ATTN: FIRE Et BUILDING DEPARTMENTS
RACK INFORMATION SUPPLEMENT
SITE ADDRESS: 12600 -B Interurban Ave S.
TENANT NAME: General Electric Aircraft Engines
DATE: February 18, 2008
APPLICANT: Mike Sorenson / (206) 818 -4488
1. Load application and shelving /rack configuration drawings attached.
2. Attached plans detail the shelvin ck locations, dimensions, and specifications. Attached
plans detail the building con ' ration.
3. Stamped engineering c ulations attached.
4. Vertical members of storage racks are designed and installed so that failure of one vertical
member will not cause collapse of more than the bay or bays directly supported by that
member.
5. Items stored in racks: Aircraft Engine Parts. Made of steel, aluminum, and other metals.
Stored in cardboard and wood boxes on wire shelves. Not banded or encapsulated.
6. Sprinkler System Information: .39 GPM / 5600 square feet. Design: 2278 ® 74.9 psi Static
pressure: 70, Residual pressure: 65.
7. Smoke and heat vents: In place but not required for this size project.
8. Building egress and exits indicated on attached drawings.
dos - 097
1100 SW 7th St
Renton, WA 98055
(425) 255 -0500 ph
(425) 228 -6946 fax
REVI ED OF D R
DE COMPL
APPROVE
FEB 2 6 200
Of Tukwila
BUILDING DIVISION
FEB 2 0 2008
PEF II II L cNTEr.
BYE G. OHANIAN
DATE. 2 -12 -08
SUBJECT
SEISMIC ANALYSIS OF STORAGE
SHELVING SYSTEM FOR:
G.E. AIRCRAFT ENGINES
12600 -B INTERURBAN AVE.
TUKWILA, WA. 98168
PER IBC 2006 EDITION
STORAGE SHELVING CAPACITY:
400 # / LEVEL
CALCS. 1 THRU 3
DRAWINGS: RD -12987
RAdK DEOI(N & EN(IINEERIN(4 do.
412 WEST BROADWAY, SUITE #204
GILENDALE, GSA. 91204
TEL:(818)240 -3810 FAX:(818)240 -3813
...
4 1) 4-017
FILE C! PY
Permit No,
EXPIRES 12 -26 -09
SHEET NO 1
JOB NO.. RD - 12987
T79VED
FEB 2 0 2008
ER1�il f CENTER
BY.% G. OHANIAN
DATE . 2-12 -08
SUBJECT
1
60"
FRONT VIEW
400 # / LEVEL
200 # / BEAM
M= 60"x.2K = 1 . 5"K
8
S = 1 .07<.12
SEISMIC DESIGN
_ S DSXI
V R x 1.4 WOR
STRESS
1 =1
R =6 MOM. CONN.
S =1
W= D.L. +L.L.
LOAD PER COLUMN
400 # / LEVEL
P= 3x.4 K - 6K
2
W =.05 +.6 =. K
D.L. L.L.
V= 1 x 1x.65 = . K
6x1.4
i
RACK DESIGN & ENGINEERING CO.
412 WEST BROADWAY, SUITE #204
GLENDALE, CA. 91204
TEL:(818)240 -3810 FAX:(818)240 -3813
N
BASE SHEAR
PER COLUMN
1
DOUBLE RIVET BEAM
1 1 3/32
IBC 2006 EDITION
ASCE 7 (SEC. 15.5.3)
48"
i
4
SIDE VIEW
x
t =14 GA.
I =.21
S x =.12
Fy =36 KSI.
• .08"
SHEET NO, 2
JOB NO.. RD -12987
By G. OHANIAN
DATE .... 2 -12 -08
SUBJECT
COLUMN
X
COMBINED STRESS RATIO
P M _.65 P + M 5.4 118 =.67<1.33
P
MOMENT AT BEAM CONNECTION
M —1 +.8 =.9 "K
CONN. 2
V R
RIVET 3.14 x80x.4 =1.5 K
IVEr
Ma = 1.5 "x1.33= 3.O"
CONN
BASE PLATE
ANCHOR SHEAR = ' K = .04
ONE 1/4 "93 ANCHOR PER BASE PLATE, 2" EMB.
HILT KB -3 (ESR 1385) OR APPROVED EQUAL
(NO SPECIAL INSPECTION REQ'D)
OVERTURNING
3 1/4"
M .08Kx2x84 "x.5x1.15 = 7.7 "K
MR = .65Kx48 "= 31 NO UPLIFT
RACK DESIGN & ENGINEERING CO.
412 WEtEiT BROADWAY, QUITE #204
( LENDALE, CA. 91204
TEL:(818)240 -3810 FAX:(818)240 -3813
A =.40
Imin —
S min .08
r min -.54
Q =.75
F Y= 36 KSI
KI = 2 6
r x .54 = 48
F 13.5 Ks!
P F = 5.4 K
M a = min F 1.8 "
BEAM -
.25 "0 RIVET
F =80 KSI
SHEET NO. 3
JOB NO. RD- 12987
COLUMN
ACTIVITY NUMBER: D08 -097 DATE: 02 -20 -08
PROJECT NAME: GENERAL ELECTRIC AIRCRAFT ENGINES
SITE ADDRESS: 12600 INTERURBAN AV S STE B
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS: 2 4406
L
Buil p I Ision
Public Works
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
TUES/THURS ROUTING:
Please Route
Documents/routing slip.doc
2 -28 -02
PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
5t1-
Fire Prevention
Structural
Incomplete
Structural Review Required
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions
Notation:
REVIEWER'S INITIALS:
7/
-_,
DATE:
Planning Division
Permit Coordinator
DUE DATE: 02 -21 -08
Not Applicable
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
No further Review Required
REVIEWER'S INITIALS: DATE:
n
r.-
DUE DATE: 03-20-08
Not Approved (attach comments) n
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
License Information
License
NORTHWH275JF
Licensee Name
NORTH WEST HANDLING SYS INC
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
600051641
Ind. Ins. Account Id
32999900
Business Type
CORPORATION
Address 1
1100 SW 7TH ST
Address 2
City
RENTON
County
KING
State
WA
Zip
980552939
Phone
4252550500
Status
ACTIVE
Specialty 1
GENERAL
Specialty 2
UNUSED
Effective Date
4/6/1973
Expiration Date
10/9/2009
Suspend Date
Separation Date
Parent Company
Previous License
Next License
NORTHHS963ND
Associated License
Bond Information
Bond
Bond
Company
Name
Bond Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
#6
TRAVS
815103354822BCM
10/01/2001
Until
Cancelled
01/01/1980
$12,000.00
10/09/2001
Business Owner Information
Name
Role
Effective Date
Expiration Date
FRANCK, JAMES J
01/01/1980
THOMAS, KEVIN A
01/01/1980
KOSTY, CLARK R
01/01/1980
Look Up a Contractor, Electrn or Plumber License Detail
Washington State Department of Labor and Industries
General/Specialty Contractor
A business registered as a construction contractor with L &I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
0
Page 1 of 3
https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= NORTHWH275JF 02/28/2008
PLAN VIEW
39 -5"
Exit
PLAN
NORTH
SITE MAP
PLAN KEY PLAN
NORTH SCALE:NTS
LOCATION:
i r k ( : ) . . 1 ± . . C; i AND [•3 k C DA T A
PARCEL NUMBER: 0004800003
ACCOUNT NUMBER : 000480000306
TUKWILA COMMERCE PARK, BUILDING A
12600 INTERURBAN AVE. 'S., SUITE 110
TUKWILA, WA
LEWIS C C—D C # 37 BEG N 81 -44 -15 E 199.17 FT FROM
HUB AT END OF CURVE ON CENT LN OF DUWAMISH — RENTON
JUNCTION RD SD HUB BEING APPROX 1200 FT N AND 440 FT
W OF 1/4 COR BET SECS 14 & 15 -23 -4 TH N 49 -24 -00 W
2535 FT TH N 09-36-00 E 52 FT TO TRUE BEG TH S
82 -40 -30 E 590 FT TH N 59 -22 -30 E 643.35 FT TH N
01 -51 -30 W 343 FT TO LEFT BANK OF DUWAMISH RIVER
BEING NLY BOUNDRY OF LEWIS D C TH SWLY ALG SD BANK
OF RIVER TO PT N 00-39-40 W OF TRUE BEG TH S
00 -39 -40 E TO TRUE BEG ALSO POR OF D C LY W OF
ABOVE DESCRIBED LAND SLY 16.15 FT AND A 16 FT STRIP
ADJ AND PARL TO ELY LN OF R/W OF P S ELEC CO FOR
JOINT RD TGW LOT 47 OF PLAT OF RIVERSIDE INTERURBAN
TRS
SEPARATE PERMIT
REQUIRED FOR:
igJ Mechanical
t Electrical
R Ie Plumbing
U Gas Piping
City of Tukwila
B1iil_p1NG DIVISION
Nod ��3 a sc (�pe
®a� �.f `,:ii w w . _ . . ` o€
NOTE: Re - eQure a . i. 13 '/Y and Ma" include additional piar ce ew fees. g
1
FILE COPY
Permit Na 012'
Plan review approval is subject to errors and omissions.
Approval of constructlon documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Field Copy and nditlons 1s acknowledged:
By ,
Date:
City of Tukwila
BUILDING DIVISION
FEB 2 0 2008
PE i'v;i i C NTE$
SHEET NUMBER
DRAWING NUMBER
w
F_
O o
U E
a
w
W W
o
7 F 0
O I
a o
w
� C
W
m p
J W
¢J W
2
to
IA
O ce
W
W
O
H
EL
Q
Z
• m
T
2
0 N n
w
w x
0 O
a o
o
w
r F
? m
a
E
¢ o
J m
o
N o
w
0 in
Z o
a
a
Q
} d
w w W
_ 3
POST
1 1/2"
f
1/4"
1 1/2"
0 0
0 0
60"
TIE PLATE
FRONT VIEW
TP (TIE PLATE)
1
48"
SIDE VIEW
" SS " BEAM
0
1/4 "0 RIVET
ASTM A345 -79
14 GA.
SHELF SUPPORT
1 3/32"
DOUBLE RIVET
2
BASE PLATE
ONE 1/4"93 ANCHOR
2" EMB. (SEE NOTE 3)
NOTES:
1- DESIGN OF STEEL STORAGE SHELVING AS SHOWN BY THESE DRAWINGS
AND CALCULATIONS ARE IN COMPLIANCE WITH THE REQUIREMENTS
OF THE CBC 2007 EDITION
2 -STEEL FOR ALL SHAPES FY =36 KSI. ASTM A570-85 GR.36 (EXCEPT AS NOTED)
3 -ALL ANCHORS HILT! KB -3 (ESR 1385) OR APPROVED EQUAL
(NO SPECIAL INSPECTION REQUIRED)
4- STORAGE SHELVING CAPACITY 400 # /LEVEL
5 -ALL SHELVING INSTALLATIONS AND SHELVING MANUFACTURED IN CONFORMITY
WITH THIS STANDARD SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS
A PERMANENT PLAQUE EACH NOT LESS THAN 50 SQUARE INCHES IN AREA
SHOWING THE MAXIMUM PERMISSIBLE UNIT LOAD OF 400 # /LEVEL
EXPIRES 12- -26 -09
A
A
REV. DATE
RACK DESIGN AND ENGINEERING
2 WEST BROADWAY, SUITE #204, GLENDALE, CA. 91204
SCALE: NONE
DATE: 2 -12 -08
—0 Ile
FEB 2 0 2006
PERM - CEN b
REVISION
G.E. AIRCRAFT ENGINES
12600 -B INTERURBAN AVE. TUKWILA, WA. 98168
NO.
STORAGE SHELVING DETAILS JOB RD D -12299
87
DRAWN BY: A.KH.
SHEET NO.