Loading...
HomeMy WebLinkAboutPermit M08-007 - WESTFIELD SOUTHCENTER MALL - LUCKY BRANDLUCKY BRAND 627 SOUTHCENTER MALL M08 -007 Parcel No.: 6364200010 Address: Suite No: Tenant: Name: LUCKY BRAND Address: 627 SOUTHCENTER MALL , TUKVVILA WA Owner: Name: WEA SOUTHCENTER LLC Address: 11601 WILSHIRE BLVD , LOS ANGELES CA Contact Person: Name: JAMES MOORE Address: 833 SE MAIN #242 , PORTLAND OR Contractor: Name: MERIT MECHANICAL INC. Address: PO BOX 2109 , REDMOND, WA Contractor License No: MERTTMI163CM DESCRIPTION OF WORK: MECHANICAL FOR NEW TI Value of Mechanical: $20,000.00 Type of Fire Protection: SPRINKLERS /AFA Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic C ommercial/Industrial doc: I MC -10/06 Cit4f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 627 SOUTHCENTER MALL TUKW MECHANICAL PERMIT EOUIPMENT TYPE AND OUANTITY 0 0 0 0 0 0 1 0 0 1 0 0 0 0 * * continued on next page ** • Permit Number: Issue Date: Permit Expires On: Phone: Phone: 503 577 -8859 Phone: 425 883 -9224 Expiration Date: 06/01/2009 M08 -007 04/23/2008 10/20/2008 Fees Collected: $384.83 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment M08 -007 Printed: 04 -23 -2008 Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied The granting of t construction or Signature: Print Name: doc: IMC - 10/06 rmit does no ormance of • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us d this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. esume to give authority to violate or cancel the provisions of any other state or local laws regulating k. I am authorized to sign and obtain this mechanical permit. Permit Number: M08 -007 Issue Date: 04/23/2008 Permit Expires On: 10/20/2008 Date: Date: 04 6-C1f This ermit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended P Y � P or abandoned for a period of 180 days from the last inspection. M08 -007 Printed: 04 -23 -2008 Parcel No.: 6364200010 Address: 627 SOUTHCENTER MALL TUKW Suite No: Tenant: LUCKY BRAND 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M08 -007 Status: ISSUED Applied Date: 01/08/2008 Issue Date: 04/23/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ** *FIRE DEPARTMENT CONDITIONS * ** 10: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 11: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 12: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 13: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 14: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 15: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC doc: Cond -10/06 M08 -007 Printed: 04 -23 -2008 104.2) • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 17: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 18: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 19: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * * continued on next page ** M08 -007 Printed: 04 -23 -2008 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this p construction or the Signature: Print Name: doc: Cond -10/06 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us does not presume to give authority to violate or cancel the provision of any other work or local laws regulating ance of work Date: M08 -007 Printed: 04 -23 -2008 Site Address: (a11 n ;; L u#- I v J Tenant Name: LA (;e TJr • _ Property Owners Name: v`P' l- ``G Mailing Address: I ( a Name:; (A `nn•C t r C.-- Mailing Address: 3 Se 42-- E -Mail Address: clQ (,,S Gi O4rj`t�" erns i' co w\- . Company Name:'' Mailing Address: Contact Person: E -Mail Address: CITY OF TUKWILP Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Contractor Registration Number: Company Name: t-►'[ VI d is cen Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Mailing Address: J 4 ( t 4—pttf Contact Person: ttc10 L-S Company Name: 4 1 \r's (. 7 E -Mail Address: Q:\Applications\Forms- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh City P� a 7r Mailing Address: 7O 3 t � � AI� Lie..t) D . D k\ t Contact Person: (.. t A5 V Y L'tt iCA, King Co Assessor's Tax No.: (x /4) 0 Expiration Date: Suite Number: /55S Floor: New Tenant:.... Yes ❑ ..No ' 61 ES State Zip Day T lephone: POr L'OV 72-13 City State Zip Fax Number: 51)5 .C.% % -21030 city Day Telephone: Fax Number: State Zip tJC - 2 ( 7 State Zip City Day Telephone: 0 1 ' "" i 40 x E -Mail Address: Fax Number: «4 " kAt A f q s-s 11 C-4 keel C7��ve C. -- et 2 - City State Zip �7 Day Telephoner 14'' S " (tj 15 x2.3 Fax Number: 11 j. 4 ` 7ZR 4 Page 1 of 6 BUILDING PERMIT INFORMATION — 206.431 -3670 Valuation of Project (contractor's bid price): $ ;� ()4 Existing Building Valuation: $ Scope of Work (please provide detailed information): ) v 1 • -f " (��3� T j VI� (C (V A r ` " o r t : / - 1 6 S +6 t - , G\ v,-4- ge2 i 4Q Vv.._ OAApplicationsTorrns-Applications On Line'3 -2006 - Permit Application.doc Revised: 9 -2006 bh Will there be new rack st age? Yes frig Ares re FOoi .. No If yes, a separate permit an plan submittal will be required. tg 11 PLANNING DIVISION: Single family building footprint (area o e foundation of all structures, plus any decks over 18 inches : • overhangs greater than 18 inches) *For an Accessory dwelling, provide e following: Lot Area (sq ft): Floor area of principal dwelling: Floor ea of accessory dwelling: *Provide documentation at shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Pr . ded: Standard: Compact: Handicap: Will there be a change in .e? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECT 1 N/HAZARDOUS MATERIALS: Sprinklers Ia., Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 "paper including quantities and Material Safe ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Unit Type: Qty Unit Type: Qty Unit Type:: " " Qty ; . Boiler /Cornptessar: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct I Thermostat 15 -30 HP /1,000,000 BTU Suspended /Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM i Incinerator — Comm/Ind MECHANICAL PERMIT IN TION - 206 - 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: I IJ � Mailing Address: Contact Person: E -Mail Address. Contractor Registration Number: Valuation of Mechanical work (contractor's bid price): $ Scope of Work (please pro side detailed information): . c, s Use: Residential: New .... Replacement .... 0 Commercial: New ...LK Replacement .... 0 Indicate type of mechanical work being installed and the quantity below: Q:\Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh City Day Telephone: Fax Number: Expiration Date: State Zip Fuel Type: Electric Gas Other: Page 4 of 6 PUBLIC WO RXS PERMIT IN Scope of Work (please provide detailed information): 1- > F " Water District ❑ ...Tukwila ❑ ...Water Availabili • rovided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate Please refers to Public Works Bulletin #i for fees and estimate shee Septic System: ❑ On -site Septic System — For on e septic system, provide 2 copies of a current s Submitted with Application (mark box- which apply): ❑ ...Civil Plans (Maximum Paper Size — " x 34 ") ❑ ...Technical Information Report (Storm Dr.' age) ❑ •technical Report ❑ ...Bond ❑ .. Insurance . Easement(s) ❑ aintenance Agreement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hour ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut cubic yards ❑ ...Total Fill cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Pr • ction Irrig s n Do > estic Water ❑ ...Permanent Water Mete ize... ❑...Temporary Water M r Size.. ❑ ...Water Only Meter e ❑ ...Sewer Main Exte on Public ❑ ...Water Main Ext Sion Public 0... Water District #125 ❑... ValVue ❑ .. Renton ❑... Sewer Availability Provided >> .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line >> Q:\Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh 1tMATION WO # WO # WO # Private Private 206 - 433 - 0179 Call before you Dig: 1- 800 -424 -5555 ❑ .. Highline ❑ .. Work in Flood Zone .. Storm Drainage nton ❑ ...Seattle c design approved by King County Health Department. ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ... Dedu • Water Meter Size ❑...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ... Hold Harmless — (ROW) FINANCE INFORMATION Fire Line Size at Property Line ❑...Water ❑...Sewer Monthly Service Billing to: Name: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: Number of Public Fire Hydrant(s) ❑ ...Sewage Treatment Day Telephone: City State Zip Day Telephone: City State Zip Page 3 of 6 PERMIT APPLICATION Nth` ..S — Applicable to all permits Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OA HORIZED AGENT: Signature: N.N. r Print Name:Arcb \,('/ r V b re-- Mailing Address: �S a 3 ¶ W � - ' 2-4z- Date Application Accepted: , 1 r I Q:\Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh y Telephone: a City Date: s `J •77 -. State Zip Date Application Expires: • ablV1) Staff Initials: (TH Page 6 of 6 Fixture Type : : . ' Bathtub or combination bath/shower Qty Fixture,Type, 1 1 Fixtu Ty Drinking fountain or water Wash fountain cooler (per head) ii re Type: Gas piping outlets Qty Bidet Food -waste grinder, , eptor, commercial indirect Clothes washer, domestic Floor drain —= Dental unit, cuspidor Shower, single he trap - Dishwasher, domestic, with independent drain Lavatory All i MEM i Building sewer or trailer park sewer Rain water . stem — per drain (• • e building) ■ Water heate d/or vent Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repai .r alteration of water pipi• _ and/or water treating e• pment Repair or altera ' of drainage or ve piping Medical gas piping system serving one to five inlets /outlets for specific gas PLUMBING AND GAS PIPIN LRMIT INFOEi iATI I'r1 206 =4 1 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: b Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: Valuation of Plumbing work (c. 'tractor's bid price): $ 10 I Q 5 Valuation of Gas Piping work (con ctor's bid price): $ Scope of Work (please provide detaile, information): 14'C ,Akrye,'w Building Use (per Intl Building Code): 1 £ ( Occupancy (per Int'1 Building Code): IAA ` Utility Purveyor: Water: Indicate type of plumbing fixtures and /or gas piping outlets be Q:\Applications'Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Sewer: City State Zi Day Telephone: Fax Number: Expiration Date: stalled and the quantity below: 1 Ic t) Page 5 of 6 RECEIPT NO: R08 -01288 Initials: WER User ID: 1655 Payee: MERIT MECHANICAL, INC. SET ID: 5000001006 SET NAME: MERIT MECHANICAL SET TRANSACTIONS: Set Member Amount City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http:/lwww.ci.tukwila.wa.us EL08 -447 90.00 EL08 -448 74.00 EL08 -449 90.00 EL08 -450 82.00 EL08 -451 66.00 EL08 -452 82.00 M07 -287 295.42 M08 -006 58.00 M08 -Q07 313.86 M08 -063 253.00 PG07 -345 168.00 PG08 -067 176.00 TOTAL: 1,748.28 TRANSACTION LIST: Type Method Description Payment Check 23706 1,748.28 TOTAL: 1,748.28 ACCOUNT ITEM LIST: Description ELECTRICAL PERMIT - NONR MECHANICAL - NONRES PLUMBING - NONRES SET RECEIPT Payment Date: 04/23/2008 Total Payment: 1,748.28 Amount Account Code Current Pmts 000.322.101.00.0 484.00 000/322.100 920.28 000/322.100 344.00 TOTAL: 1,748.28 1523 04/23 9711 TOTAL 1748.28 RECEIPT NO: R08 -00052 Initials: JEM Payment Date: 01/08/2008 User ID: 1165 Payee: PRECISION PERMIT SERVICE SET ID: S000000935 SET NAME: LUKCY BRAND SET TRANSACTIONS: Set Member Amount • City of Tukwila Department of Community Development 6300 Southeenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: //www. ci. tukwila. wa. us D08 -011 713.05 EL08 -023 143.50 M08 -007 70.97 PG08 -006 29.00 TOTAL: 956.52 SET RECEIPT • Total Payment: 956.52 TRANSACTION LIST: Type Method Description Amount Payment Check 5323 956.52 TOTAL: 956.52 ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES Account Code Current Pmts 000.345.832.00.0 143.50 000/345.830 813.02 TOTAL: 956.52 6971 . 01/08 9710 TOTAL 956.52 Project: ` i 1. t (—\‘—•\ CO Type of Inspection: � 1•AP..\ . t\ e e Address: C0 1 te a.-\\ Date Called: • Special Instructions: Date Wanted: 7 a.m. , 0% p.m. Requester: Phone No: 2102 ' 301 — IO(03 INSPE ION NO. Approved per applicable codes. INSPECTION RECORD Retain a copy with permit Pao % - ao PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Corrections required prior to approval. Inspector: ),:)21 El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be Paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. COMMENTS: k A4 \ .1 Date: 7 - 7, Q Receipt No.: (Date: Project: e"?.. Type of Inspection: Address: C0 - 7- - - 1 P,6..\ Date Cafred: Special Instructions: Date Wanted: a.m. 1 "'1 . °f L . C) p.m. 9 Requester: Phone No , (26z1367 —f pCo3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. Inspector: ■ Date: 1 • 2 bcic ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: OMMENTS: •.2. (oZ7 f ReDult., • 4e I\C _ - \� • Project: n bAl 44c Type o Inspection: v,...` Address: / Called: Special Instructions: Date Wanted: `'7 / / (f / (bq a.m. p.m. Requester: Phone Not ,2 - 34.— i s:3(02 Ej Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 t 6 - 00-1 PERMIT NO. (206)431 -3670 121 Corrections required prior to approval. COMMENTS 61 / 4 -9fVse va ( COI Ned c� Ccdroct IS illSo.o Y10 . 4 (Date: if! /et I nspector: El $60.00 REINSPECTION FEE REdUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: / ` ©M Type of Inspection: Address: Date Called: Special Instructions: Date Wanted: ,,1 r f 0 S , a.m. P.m. Requester: Phon o: ..... qq. r � Inspector: Approved per applicable codes. • Mer oa f► . INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Corrections required prior to approval. COMMENTS: a eit d c 4 4.< off v Vet I C.44141.0 /wet - trl sK• ,'gi a A — 4 'Date: 1 /1/ El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date:- • . • • • • Project: � uc� / � T ype o f Inspection: F, .4,1 Address: `� l�J�/ �rp`lG�l/ Date Called: Special Instructions: Date Wanted: ` /b 41 / Requester: Phone No: .26? 3CA IDG3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION : 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 J [ Approved per applicable codes. Corrections required prior to approval. COMMENTS: I I ca le El $6 0 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: I-0041 ' C. A -A. Type of Inspection: �iv. r. r An� 6C u3\A NJ Address: C.:1- t \\ Date Called: Special Instructions: Date Wanted: G . `L . U`b a.m. p.m. Requester: Phone No: 7Cp7 '- ..)t \() c: h r,� INSPECTION NO. Insp c� tor: INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION it- 6300 Southcenter Blvd:, #100, Tukwila, WA 98188 (206)431 -3 COMMENTS: \(0- 1 � `� 6f-S.% gWS‘ Approved per applicable codes. Corrections required prior to approval. Dat G, •G, ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: Project: z 7 /(f* .ice, Type of Inspection: 4)/ — 1)1/ Ad ss: dr 4z7 /71/5 Date Called: Special Instructions: Date anted: -- C' 2 —,e76 a.m. cam: Requester: Phone No: � Al 3' f UiJ INSPECTION NO. {\o INSPECTION RECORD Retain a copy with permit / PERMIT NO. (206)431 -3670 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Corrections required prior to approval. 7 COMMENTS: o t , Inspector: Date: $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: • Project4 / ,'/ f e TVPe le) / ct : , t A/ Address: Date Called: Special Instructions: Date Wanted: 5"-2! C.m' p m. Requester: Phone No: 4- INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION I 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: - 5,9 ks 4404- - ro 1'tv52 4 7 Ins REINSPECTION EE REQUIRED. S¢7 — $: 00 . Prior o inspection, fee must be Id at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: Project: L ue r•(y '2 //,fig - #` .Type of Inspection: P4 /Al -c N 1:Avx-- Address: 6 7 ✓ e Suite #: / 7 4 „ Contact Person: 4 f1- :5/4. ti,t/ 0 Special Instructions: Occupancy Type: Phone No.: 21 2 - _3. e' / /'! Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 3 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Approved per applicable codes. Corrections required prior to approval. ii COMMENTS: ote H �iAl OH Inspector: 4 1 /,�,�Q�,/ 5 i2 Date: U `5 7 Ug . / Hrs.: n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Jennifer Marshall - Lucky Brand Jeans From: "Rob Humphrey" <rob @fasterpermits.com> To: <jmarshall @ci.tukwila.wa.us> Date: 01/23/2008 8:44 AM Subject: Lucky Brand Jeans Permits PermitNumber D08 -011 M08 -007 PG08 -006 EL08 -023 Jennifer, Our client had asked us to submit revised plans for this project, which resulted in changing the review status to "on hold ". They have since changed back to the original plan that is currently submitted and in your possession. Can you please place the plan review status back to "under review'? Please reply when this has been completed. Were any checksheets written for any of the reviews prior to this request? Please let me know if you require anything further. Kindest regards, ROB HUMPHREY 1 Owner FASTER PERMITS rob@fasterpermits.com www.fasterpermits.com 833 SE Main Street # 242 Portland OR 97214 503- 320 -5030 503 - 296 -2630 fax "Forgiveness is the fragrance that the violet sheds on the heel that has crushed it" - Mark Twain No virus found in this outgoing message. Checked by AVG Free Edition. Version: 7.5.516 / Virus Database: 269.19.7/1234 - Release Date: 1/20/2008 2:15 PM Page 1 of 1 fi le•//CATInrnmente /Ofl antio /.70Settinvc \ienni fetr -m \T . ncca1 %2OSettinus \Temn \XPGrnWic... 01 /21/2008 ACTIVITY NUMBER: M08 - 007 DATE: 01 - - PROJECT NAME: LUCKY BRAND SITE ADDRESS: 627 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Public Works n Complete d Comments: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 � PERMIT CHORD COM PLAN REVIEW /ROUTING SLIP d Structural Review Required APPROVALS OR CORRECTIONS: 614 Aiv, Fire Prevention l Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n n No further Review Required DATE: DATE: Planning Division Permit Coordinator n DUE DATE: 01-10-08 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: n DUE DATE: 02-07 -08 Approved I Approved with Conditions 71 I Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License MERITMI163CM Licensee Name MERIT MECHANICAL INC Licensee Type CONSTRUCTION CONTRACTOR UBI 600517946 Ind. Ins. Account Id 46817500 Business Type CORPORATION Address 1 PO BOX 2109 Address 2 City REDMOND County KING State WA Zip 980732109 Phone 4258839224 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 2/14/1984 Expiration Date 6/1/2009 Suspend Date Separation Date Parent Company Previous License Next License AUTOMMC044QH Associated License Business Owner Information Name Role Effective Date Expiration Date KIRKWOOD, RODERICK V PRESIDENT 02/14/1984 Bond Amount KIRKWOOD, JOAN M SECRETARY 02/27/2006 FRICKBERG, WILLIAM MICHAEL VICE PRESIDENT 02/27/2006 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date Look Up a Contractor, Elects n or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. • Page 1 of 3 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= MERITMI163CM 04/23/2008 4. -: :UIVERSIFFFED- :ARCHITECTURAL CONSULTING 1901 Newport Blvd. suite #300 Costa Mesa, Ca. 92627:`: _:.'::- ';...':!. Ph. 949.698.1400 Fax 949.6981433 sue, MECHANICAL 3D M1 CODED NOTES EXTEND AND CONNECT 14 "0 S.A. PRIMARY DUCT TO EXISTING MAIN S.A. DUCT.FIELD VERIFY EXACT SIZE AND LOCATION PRIOR TO BID AND CONSTRUCTION. EXTEND AND CONNECT 6 "0 EXHAUST DUCT TO EXISTING MAIN EXHAUST DUCT. FIELD VERIFY EXACT LOCATION PRIOR TO BID AND CONSTRUCTION. 0 MECHANICAL CONTRACTOR SHALL PAINT THE DIFFUSERS AND GRILLES TO MATCH THE COLOR OF THE CEILING 1. ALL WORK SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES, LAWS, ACTS AND ALL AUTHORITIES HAVING JURISDICTION, LANDLORD'S CRITERIA AND AS PER LATEST EDITIONS OF ASHRAE AND SMACNA. 3. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES, DOCUMENTS AND SERVICE'S RELATED TO INSTALLATION OF THE WORK PRIOR TO SUBMITTING A PROPOSAL, THE CONTRACTOR SHALL VISIT THE SITE AND THOROUGHLY INSPECT ALL EXISTING CONDITIONS TO INSURE THAT THE WORK REPRESENTED ON THE DRAWINGS AND IN THESE SPECIFICATIONS CAN BE INSTALLED AS INDICATED. 5. ALL WORK SHALL BE LOCATED TO AVOID CONFLICTS WITH OTHER TRADES PROVIDE ADEQUATE CLEARANCE FOR ARCHITECTURAL DESIGN, PROPER OPERATION AND SERVICE OF EQUIPMENT. 7. VERIFY LOCATION OF ANY PENETRATION OF ROOF WITH LANDLORD. ALL ROOF PENETRATIONS, PATCHING, AND FLASHING SHALL BE BY LANDLORD'S ROOFER AT MECHANICAL CONTRACTOR EXPENSE. 2. THE COMPLETED INSTALLATION SHALL BE IN ACCORDANCE WITH ALL APPLI- CABLE INDUSTRY STANDARDS OF GOOD PRACTi...•E AND SAFE 1 Y; AND THE MANUFACTURERS STRICTEST RECOMMENDAMNS FOR EQUIPMENT AND PRO- DUCT APPLICATION AND INSTALLATION. 6. PROVIDE A READY -TO -USE SYSTEM WITH ALL WORK GUARANTEED IN WRITING AGAINST DEFECTIVE WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR FROM TURN OVER TO OWNER. 8. LOCATIONS OF HVAC EQUIPMENT AND DUCTS SHOWN ARE SCHEMATIC ONLY. VERIFY STRUCTURAL DETAILS AND OTHER DETAILS THAT WILL AFFECT ROUTING AND PLACEMENT OF THESE COMPONENTS. IF MORE SUPPORTS ARE NEEDED FOR HVAC EQUIPMENT, COORDINATE WITH THE ARCHITECT. 9. ALL DUCT SIZES SHOWN ARE CLEAR INSIDE. ALL DUCTS TO BE SHEET METAL DUCTS AS PER ASHRAE AND SMACNA GUIDELINES. / CEF \ (io HVAC GENERAL NOTES ■■ E■■■ ■■■■■e ■■■■■■■ ■■■ MEM ■■ ■.111■ •■ ■■■■ 111111111111111 11111,111111 :;;'� 6 13 1 = ■■■■i[(L,1 CFM ■n ■ ■■■ ■i11�� ■ ■ ■ ■f1111■ ■■ =- ■ ■ ■1 ■■■ 1111 ■■■■■ I■�Irsi�i l��ii - ......... FPVAV -1 ri► ■ 1 T \ 1 C-22 "X22" D -6 "X6" . 3 1 20 "x18" 7.1 12 "o L i A -12 450 CFM NOTE : FPVAV INSTALLATION ACCEPTANCE MAY BE SUBJECT TO CONSTRUCTION REVIEW BY AN INDEPENDENT AIR CONDITIONING FIRM. PRIOR TO CONSTRUCTION/ BID THE CONTRACTOR SHALL VISIT THIS SITE AND FIELD VERIFY THE EXISTING LOCATIONS AND SIZES OF ANY LANDLORD PROVIDED, OR EXISTING, OUTSIDE AIR INTAKES THROUGH ROOF, LANDLORD PROVIDED CHILLED/HOT WATER PIPING MAINS, TOILET EXHAUST MAINS, OUTSIDE AIR DUCTWORK, CONDENSATE LINE MAINS, ETC. THE CONTRACTOR SHALL FIELD VERIFY ANY/ CONDITIONS WHICH MAY CONFLICT WITH THE DESIGN SHOWN ON THESE PLANS. NOTIFY ARCHITECT IMMEDIATELY, 13- ALL SUPPLY DIFFUSERS AND RETURN GRILLES PASSING THROUGH FIRE RATED CEILING SHALL HAVE APPROVED,'FIRE DAMPER. 16. CONTRACTOR SHALL STENCIL TENANT NAME AND SPACE NUMBER ON THE UNIT. 17. UPON COMPLETION OF THE WORK, THE MECHANICAL CONTRACTOR SHALL TEST, START -UP AND BALANCE THE SYSTEM(S) AND MAKE ANY ADJUSTMENTS AS REQUIRED TO INSURE PROPER WORKING ORDER. THE CONTRACTOR SHALL ALSO SUBMIT 3 COPIES OF THE AIRJWATER BALANCING REPORT. SUCH BALANCING SHALL BE PERFORMED BY AN INDEPENDENT AIRNUATER BALANCING CONTRACTOR, CERTIFIED BY THE ASSOCIATED AIR BALANCE COUNCIL. 10. PROVIDE PROPER DUCT TRANSITIONS FOR ACTUAL HVAC UNITS INSTALLED. ROOF PENETRATIONS, TO BE MADE AS PER L.L. SPECS. VERIFY DETAILS WITH L.L.. 11. REMOVE AND DISPOSE ALL UNUSED PIPING, DUCTWORK, AND ACCESSORIES. DO NOT ABANDON. 12. COORDINATE ACTUAL LOCATIONS OF DIFFUSERS, REGISTERS AND GRILLES WITH CEILING DETAILS AND OTHER FEATURES SUCH AS LIGHTING FIXTURES ETC. THAT MAY AFFECT PLACEMENT OF THE HVAC SYSTEM COMPONENTS. 14 . PROVIDE AND INSTALL PROGRAMMABLE THERMOSTATS AS SHOWN ON THE PLAN AT A MINIMUM OF 3FT -4FT MAXIMUM AFF (VERIFY LOCAL CODE). COORDINATE EXACT LOCATION WITH ARCHITECT. PROVIDE WIRING AND CONTROLS AS REQUIRED. 15. GENERAL CONTRACTOR SHALL SUPPLY ALL EQUIPMENT CONTROLS AND WIRING. COORDINATE WITH MALL REPRESENTATIVE FOR INTERLOCKING WITH MALL CONTROL SYSTEM (IF REQUIRED). v 1 D-6"X6" D -6'x6" D -6"X6" A -10 320 CFM 811111111 II111111 LI 11I!.I111II 1!1111!. ,1!11111 IIIL11111111III 11111II11111111 I!!!IIII111111 111111111111!Il 1111:1!!:1111111 I11111!;1111I11I 111I1IiIIII11 11 I " s `p0 1 iiv7 • r i Ct 4 - .... S tin c ;'i 71 y Subrrlittat 3's cIU e '.io t onat plan t ti8WW D -6'x6' ( 2 \\ MECHANICAL PLAN M1.o PER 2006 IMC SECTION 606 Install smoke detector to shut down air distribution by VAV's when the total combined C F M of all VAV's (to include other tenants) sharing the same plenum space exceeds 2000 CFM. (See IMC 606.2.2 for approved method of detection) SPRINKLER NOTES 2. ALL WORK SHALL BE SCHEDULED WITH LANDLORD'S FIELD REPRESENTATIVE. 3. ALL SYSTEM SHALL BE CHARGED AND OPERATIONAL WtiEN THE CONTRACTOR IS NOT ON THE PREMISES. 4. SPRINKLER CONTRACTOR SHALL INCLUDE A REFLECTED CEILING PLAN WHICH REVEALS THE LOCATION OF ALL THE RELEVANT EXISTING SPRINKLER HEADS, LIGHT FIXTURES, AIR SUPPLY DIFFUSERS, RETURN GRILLES AND EXISTING ITEMS, SUCH AS DUCTWORK THAT MIGHT DEFLECT SPRINKLER'S SPRAY PATTERNS, VERIFY HEIGHT OF SPRINKLER HEADS ABOVE STORAGE PLATFORMS. 5. SPRINKLER CONTRACTOR SHALL PROVIDE A SPRINKLER DESIGN AND AN INSTALLED SYSTEM ACCORDING TO NFPA 13. 6 STORAGE HEIGHT SHALL BE A MINIMUM OF 18" BELOW THE SPRINKLER HEAD. THE REAR STORAGE WALLS SHALL BE MARKED TO INDICATE STORAGE HEIGHT, MAINTAINING THE 18" BELOW THE SPRINKLER HEADS- 11 A -10 11320 CFM !I ! 1 _ • 1. LANDLORD APPROVED CONTRACTOR SHALL BE EMPLOYED BY THE TENANT TO MODIFY, INSTALL SYSTEM AND PREPARE CONTRACTS DOCUMENTS PER CODE AND LANDLORD'S INSURER APPROVAL. FILE C..PY Permit No. Plan review approval is subject to errors and om Approval of construction documents does not autho the violation of any adopted code or ordinance. R of :.. . ' d c an r. . 1 . - SEPARATE DERMIT REQUIRED FOR: ❑ Mechanical VElectrica) E lumbig ar Gas Piping City of Tu kwila BUILDING D. VISION (E) (N) (L) S.A. R.A. E.A. C P.D.C. FPVAV -1 City of Tukwila suR SIN( O3ViS ON LINED C- 22"X22 10"o NEW SUPPLY AIR DIFFUSER NEW RETURN AIR GRILLE 1 .1 EXISTING SUPPLY AIR DIFFUSER EXISTING RETURN AIR GRILLE A.P. ACCESS PANEL DOOR UNDERCUT EXISTING NEW AIR FLOW (R.A. CR S.A.) EXISTING AIR GRILLE THERMOSTAT DUCT SMOKE DETECTOR POINT OF CONNECTION A -10 385 CFM A -10 385 CFM J) `Lx (G.8) ( G. 5 0., i ■ PRO3ECTTEAM • . PRINCIPAL IN CHARGE PROJECT MANAGER EM SG /GM REVISIONS : " MECHANICAL PLAN 625-4089-01 12/21/07 NO REASON DATE The Owner reserves the right to check construction compliance with plans and specifications. Should the owner find corrective work to be necessary, he will 41 otify contractor of such work in writing and expect compliance performed with ` due diligence. If any corrective work is deemed to be necessary, the cost of neinspeclions will be borne by the contractor. If work is required by Owner in i to improve, change or correct air conditioning operational conditions due v6�4; part malfunction, warranty or other inability to provide the comfort e � bnditions required by the store, contractor shall be directed by Lucky Brand Jeans, to address this work in a timely manner. If it becomes evident that the contractor can not accomplish the task, then after 72 hours of written notice, the owner may at his discretion take over such work and backcharge the contractor for any corrective work that was required due to lack of performance, workmanship and/or adherence to plans and specifications." LEGEND AND SYMBOLS (N) 1 MVD NEW DUCTWORK NEW DUCTWORK EXISTING DUCTWORK TO REMAIN EXISTING DUCTWORK TO BE REMOVED FLEXIBLE AIR DUCT MANUAL VOLUME DAMPER AFD APPROVED FIRE DAMPER CFSD COMBINATION FIRE/SMOKE DAMPER _A-10_ 4' r. ABD AUTOMATIC BACKDRAFT DAMPER DIFFUSER TYPE/NECK SIZE CFM REQUIRED www.Iittleonline.com This drawing and the derign show: are the properly of Little Diaerrifred Architectural Consulting. The reproduction, copying or other rue of this drawing Without their u ritten omen/ it prohibited and any infringement gill he m ed to legal action. cr .' - -- -- as i J_Ay t...-0 Jtct - .,-- DUNG sr .M.EILICA. / roo Spi1C.7S TP DYE �? _ 0 �PRO]ECPIVII;ME== ;"'v °s,- : •x.`:' yr� : _ __ ._ 00 © Little 2007 DON PENN CONSULTING ENGINEER 635 WESTPORT PARKNAY, slot 300 GRAPEVINE. TEXAS 76051 817 -410.2858 FAX 817 -251 -8411 cr Q co ,gc re De e 0 J 0 8 c8A8 P ... ._., , ; EF 1901 Newport Blvd. suite: # 3 : .._ Costa Mesa, Ca. 92627 Ph: :'949.698:1400 "' Eax 949:698.1433'' 'CCIENT`NAh1E "^._�. r.....,. 4 NAME:;.:::;::: '.:�_''" PROJECT TEAM.': = :'r= ._.LL:. •:. PRINCIPAL IN CHARGE HHH PROJECT MANAGER EM SG /GM NO REASON DATE 625- 4089 -01 i/SSUEOA - ,SHEET N .. 12/21/07 MECHANICAL 3D VIEW 1 MECHANICAL 3D VIEW M1.1 ol 1 EXPIRES DEC 2 0 20 www.littleonline.cam This drawing and the design shoal! an the property of Little Diterafied Arcbitectural Consulting. The reproduction, copying or other use of this draximg uithaut their oriaen consent is prohibited and any infringement mill be sul ett to legal action. dp Little 2007 DON PENN CONSULTING ENGINEER 635 WESTPORT PARKWAY, SUITE 300 GRAPEVINE, TEXAS 76051 817 -410 -2858 FAX SIT-251-8411 8 2008 Eh VAV TERMINAL BOX SCHEDULE MARK MANUFACTURER MODEL SIZE CFM WEIGHT (LBS) REMARKS FPVAV -1 TITUS DTQS, 14 2710 50 " E THERMOSTAT WITH REMOTE TEMPERATURING SENSOR. - HEAT GAIN CALCULATION DATA - PROJECT NAME LUCKY BRAND JEANS- SOUTHCENTER, TUKWILA, WA SPACE NAME SALES AREA NON -SALES AREAS NON -SALES AREAS AREA (SQ. FT.) 2,113 339 339 CEILING HEIGHT (FT.) Varies varies varies VOLUME (CU. FT.) 48,599 5,376 EXTERIOR 5,424 FACTOR FACTOR QUANTITY BTUH QUANTITY FACTOR QUANTITY BTUH SENSIBLE GAINS DAY CYCLE ROOF 0.1 4 0 0 0 0.1 0 0 0 GLASS (SOLAR) -NORTH 0.95 0.08 0 0 0 0 0 0 GLASS GLASS (SOLAR)-SOUTH 0 0 0 0 0 7 PARTITION 0 0 GLASS (SOLAR) -EAST 0 0 0 0 CEILING 0 0 0 0 GLASS (SOLAR) -WEST 0 9 OUTSIDE AIR 0 0 0 1.085 0 0 SKYLIGHT SAFETY FACTOR 0.03 0 0 0.03 0 0 0 SUBTOTAL (4 THRU 10) GLASS (CONVECTION) 1.13 0 0 0 0 l NIGHT CYCLE ' 12 0 0.1 WALL - NORTH 0.08 0 0 0 13 WALL 0.08 0 0 WALL -SOUTH 0 0 0 0 0.95 0 0 0 0 WALL - EAST 0 PARTITION 0 0 0 0 0 0 16 WALL - WEST 0 0 0 0 0 0 0 0 0.03 PARTITION 0 0.03 0 0 18 SUBTOTAL (12 THRU 17) 0 0 0 FLOOR 0 0 INTERIOR GAINS 0 19 LIGHTS (50% CREDIT) 3.41 3,41 6,339 0 3.41 PEOPLE 250 20 21 42 10,500 1,000 250 1 250 4,000 INFILTRATION VENT r l 14,808 0 5,734 NET HEAT LOSS 0 19 LIGHTS 3.41 6,339 21,616 AVERAGE LOAD /SQ. FT. a41 1,017 3,468 20 EQUIPMENT 4 1,000 4,000 TENANT TOTAL HEAT LOSS 4 1000 4,000 21 SAFETY FACTOR 0.03 1,083 0.03 232 22 OUTSIDE AIR 0. 0 0 0.22 0 0 23 SUBTOTAL(4 THRU 16) - - 37,199 7,950 LATENT GAINS 24_1_ 25 ; PEOPLE 200 `' 42 8,400 . 200 1 200 INFILTRATION VENT 0 0 26 1 SAFETY FACTOR 0.03 • 252 0.03 • • 6 27 TS1T3E AIR = . 0.14 O .. 0 • 0.,14 , 0 . - 28 CI IRARAAOV i SUBTOTAL (18 THRU 21) , 8,652 1 206 _ • . ____ HEAT LOSS CALCULATION DATA W311 PROJECT NAME LUCKY BRAND JEANS- SOUTHCENTER, TUKWILA, WA SPACE NAME SALES AREA NON -SALES AREAS 1 AREA (SQ. FT.) 2,113 339 2 CEILING HEIGHT (FT.) varies varies 3 VOLUME (CU. FT.) 45,034 5,376 EXTERIOR FACTOR QUANTITY BTUH FACTOR QUANTITY BTUH LOSSES DAY CYCLE 4 ROOF 0.1 0 0 0.1 0 0 5 WALL 0.08 0 0 0 0 0 6 GLASS 0.95 0 0 0 0 0 7 PARTITION 0 0 0 0 0 0 8 CEILING 0 0 0 0 0 0 9 OUTSIDE AIR 1.085 0 0 1.085 0 0 10 SAFETY FACTOR 0.03 0 0 0.03 0 0 11 SUBTOTAL (4 THRU 10) 0 0 0 0 0 0 l NIGHT CYCLE ' 12 ROOF 0.1 0 0 0 0 0 13 WALL 0.08 0 0 0 0 0 14 GLASS 0.95 0 0 0 0 0 15 PARTITION 0 0 0 0 0 0 16 CEILING 0 0 0 0 0 0 17 SAFETY FACTOR 0.03 0 0 0.03 0 0 18 SUBTOTAL (12 THRU 17) 0 0 0 0 0 0 INTERIOR GAINS DAY CYCLE 19 LIGHTS (50% CREDIT) 3.41 3,41 6,339 10,808 3.41 1,017 1,734 20 21 OTHER (EQUIPMENT) 4 1,000 4,000 4 1,000 4,000 SUBTOTAL (19 AND 20) r l 14,808 5,734 NET HEAT LOSS 22 DAY CYCLE ROOM LOAD 0 0 23 AVERAGE LOAD /SQ. FT. 0 0 24 -. - 25 TENANT TOTAL HEAT LOSS 0 NIGHT CYCLE - 26 TENANT TOTAL HEAT LOSS 0 WORK INCLUDED: EACH CONTRACTOR SHALL VERIFY LANDLORD REQUIREMENTS. BID AND INSTALLATION SHALL BE BASED ON SUCH REQUIREMENTS, DRAWINGS AND SPECIFICATIONS. MECHANICAL CONTRACTOR SHALL COORDINATE ALL MECHANICAL WORK WITH THAT OF OTHER TRADES ON THE PROJECT PREVENTING UNNECESSARY CONFLICTS OR DELAYS DURING CONSTRUCTION. IF FOR ANY REASON EXISTING EQUIPMENT TO BE RE -USED NEEDS REPLACEMENT PARTS, THIS COST 1S TO BE COVERED UNDER ORIGINAL CONTRACT AMOUNT AND WILL NOT BE ACCEPTED AS AN EXTRA COST OR EXPENSE CONTRACTOR MUST INSPECT ALL EQUIPMENT TO BE RE -USED AT TIME OF BIDDING OR NEGOTIATING PERIOD. CONTRACTOR SHALL EXAMINE THE SITE, COMPARE IT WITH DRAWINGS AND SPECIFICATIONS AND BECOME FAMILIAR WITH EXISTING CONDITIONS BEFORE SUBMITTING A BID. NO ALLOWANCE WILL SUBSEQUENTLY BE MADE IN BEHALF OF THIS CONTRACTOR BY REASON OF ANY ERROR ON HIS PART. CODES AND STANDARDS: ALL CODES, ORDINANCES, RULES, REGULATIONS, ORDERS, AND OTHER LEGAL REQUIREMENTS WITH WHICH COMPLIANCE IS REQUIRED BY GOVERNING AUTHORITIES SHALL BE ADHERED TO. SCOPE A. THE WORK COVERED BY THIS SPECIFICATION INCLUDES THE COMPLETE HEATING AND AIR CONDITIONING SYSTEM. B. THE WORK TO BE PERFORMED UNDER THE HEATING AND AIR CONDITIONING SPECIFICATIONS AND DRAWINGS CONSISTS OF FURNISHING ALL LABOR AND MATERIAL FOR THE COMPLETE INSTALLATION OF ALL HEATING AND AIR CONDITIONING SYSTEM FOR TENANT SPACE. THE WORK SHALL INCLUDE, BUT SHALL NOT BE LIMITED TO, THE FOLLOWING: 1. HEATING /COOLING UNITS 2. AUTOMATIC TEMPERATURE CONTROL 3. DUCTWORK AND AIR CONTROL 4. USE OF CRANE TO PLACE ROOF TOP EQUIPMENT (WHEN REQUIRED) GENERAL: A. THIS SPECIFICATION IS INCLUSIVE FOR EACH ITEM REQUIRING ALL LABOR, MATERIAL, • EQUIPMENT PROPERLY INSTALL- ALTER,- ADJUST; AND PUT IN -- - - OPERATION, THE COMPLETE HEATING AND AIR CONDITIONING SYSTEM. B. THE CONTRACTOR IS RESPONSIBLE FOR THE PROPER LAYOUT AND CONSTRUCTION OF THE `WORK INCLUDED IN THIS CONTRACT. ' LAWS, ORDINANCES AND REGULATIONS: A. ALL SYSTEMS IN ALL AND /OR PART SHALL CONFORM TO ALL PERTINENT LAWS, ORDINANCES AND REGULATIONS OF ALL BODIES HAVING.JUR1SDICTION; AT ALL - GOVERNING LEVELS; NOTWITHSTANDING ANYTHING IN THESE DRAWINGS OR SPECIFICATIONS TO THE CONTRARY. IN CASE OF' CONFLICT BETWEEN GOVERNING LEVELS, THE MORE STRINGENT LAWS SHALL APPLY B. THE CONTRACTOR SHALL PAY ALL FEES AND OBTAIN AND PAY FOR ALL PERMITS AND INSPECTIONS REQUIRED BY ANY AUTHORITY HAVING JURISDICTION IN CONNECTION WITH HIS WORK MATERIALS AND EQUIPMENT: A. ALL MATERIALS SHALL BE NEW AND SHALL BE OF THE TYPE AND SHALL MEET THE CAPACITIES OF EQUIPMENTSPECIFIED ON THE DRAWINGS. ALL MATERIALS AND EQUIPMENT UTILIZED SHALL BE MANUFACTURED IN THE UNITED STATES OF AMERICA B. ALL EQUIPMENT OFFERED UNDER THESE SPECIFICATIONS SHALL BE LIMITED TO PRODUCTS REGULARLY PRODUCED AND RECOMMENDED FOR SERVICE, IN ACCORDANCE WITH ENGINEERING DATA, RATINGS, OR OTHER COMPREHENSIVE LITERATURE MADE AVAILABLE TO THE PUBLIC AND IN EFFECT AT THE TIME OF OPENING OF BIDS. C. EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS FOR TYPE AND CAPACITY OF EACH PIECE OF EQUIPMENT USED. WORKMANSHIP: A. ALL HVAC EQUIPMENT SHALL BE INSTALLED IN A WORKMANLIKE MANNER MEETING THE ACCEPTED STANDARDS OF THE INDUSTRY. THE WORK SHALL BE DONE BY SKILLED CRAFTSMAN. CUTTING, PATCHING AND PAINTING: UNLESS OTHERWISE DIRECTED BY THE LANDLORD CRITERIA, THE CONTRACTOR SHALL PERFORM ALL CUTTING AND PATCHING REQUIRED IN CONNECTION WITH HIS WORK ALL FINISHED SURFACES THAT ARE CUT SHALL BE REPLACED IN KIND SO THAT THERE ARE NO VISIBLE EVIDENCE OF "PATCH ". PAINTING OF MECHANICAL WORK SHALL BE BY PRIME CONTRACTOR. ALL EQUIPMENT WHICH HAS HAD THE FINISH DAMAGED BY INSTALLATION OR TRANSPORTATION SHALL BE REFINISHED. ROOF AND OTHER PENETRATIONS: EACH CONTRACTOR REQUIRING OPENINGS IN THE ROOF OF THE BUILDING STRUCTURE (WHERE REQUIRED) SHALL MAKE ARRANGEMENTS WITH THE LANDLORD FOR SUCH OPENINGS. PROCEDURE AND COST ARRANGEMENTS SHALL BE OUTLINED IN THE LANDLORD CRITERIA. COMPLY WITH ALL LANDLORD REQUIREMENTS. ALL ROOF PENETRATIONS SHALL BE ARRANGED TO PROVIDE A WEATHER -TIGHT INSTALLATION. THE INSTALLATION SHALL INCLUDE, WHERE REQUIRED, VENTILATING COLLARS TO GIVE PROPER CLEARANCE FROM COMBUSTIBLE ROOFS, FLOORS, CEILINGS OR OTHER SUCH STRUCTURES. FIRE - PROOFING SHALL BE PROVIDED USING MATERIALS CONFORMING WITH MUNICIPAL CODES AND ORDINANCES. ALL ROOFING WORK SHALL BE DONE BY LANDLORD ROOFING CONTRACTOR AT G.C. EXPENSE. MARK CEF -1 MARK A .. _. _._ B C D MANUFACTURER AND MODEL BROAN MODEL 676 SERVICE SUPPLY SUPPLY RETURN RETURN MECHANICAL SPECIFICATIONS EXHAUST FAN SCHEDULE AIR FLOW (CFM) 100 S.P. (IN.H20) LAY-IN 0.125 MOUNTING TYPE LAY-IN GYP. BD. APPLICATION LAY -IN GYP. BD. APPLICATION ELECTRICAL VOLT/PH 120/1 AIR DEVICE SCHEDULE MODULE SIZE 24 "X24" ROUND 24 "X24" 12"X12" WATTS 57 REMARKS INTERLOCKED WITH LIGHT SWITCH MANUFACTURER AND MODEL TITUS - TMSA TITUS - TMR TITUS - 50F TITUS - 50F DUCTWORK A. ALL DUCTWORK SHALL BE AS SHOWN ON MECHANICAL DRAWINGS AND SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF ASHRAE THE SMACNA MANUAL. B. DUCTWORK SHALL BE "FACTORY MADE" CLASS 1 GALVANIZED SHEET METAL WITH IRON SUPPORTS SECURED TO OVERHEAD MEMBERS AT 5' -0" DUCTWORK MATERIALS SHALL BE PER LOCAL CODE. C. DUCTWORK SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH ASHRAE AND LATEST SMACNA STANDARDS. PROVIDE TURNING VANES IN ALL ELBOWS; AND MANUAL VOLUME DAMPERS IN ALL BRANCHES, SPLIT - PER DAMPERS, AIR EQUALIZERS, EXTRACTORS, AND SIMILAR DEVICES • WHEREVER NECESSARY TO PROPERLY BALANCE THE SYSTEM AND PRODUCE A QUIET AND DRAFTLESS OPERATION. D. EXPOSED DUCTWORK SHALL BE STANDARD SPIRAL ROUND GALVANIZED SHEET METAL DUCTWORK 24 GAUGE UP TO 36 ", 22 GAUGE -36" TO 50 ". E. THE DUCTWORK SHALL BE OF THE SIZES SHOWN ON THE DRAWINGS. F. FLEXIBLE DUCTWORK SHALL BE THERMAFLEX "M -KE" WITH ONE INCH EXTER- NAL INSULATION FINISHED WITH A VAPOR BARRIER, U.L. AND 90A LISTED, SHALL BE EQUIPPED WITH DAMPER - EXTRACTOR AT THE SHEETMETAL DUCT AND CIRCULAR COLLAR AT THE DIFFUSER, MECHANICALLY SECURED. G. FLEXIBLE DUCTWORK SHALL NOT EXCEED 5 FEET IN LENGTH; BENDS SHALL NOT RESTRICT THE INSIDE CROSS-SECTIONAL AREA OF THE DUCT; AND CONNECTION SHALL BE MADE AS DIRECT AS POSSIBLE TO THE MAIN SUPPLY. DUCTWORK INSTALLATION: INSULATE ALL NEW SUPPLY, RETURN AND EXHAUST DUCTWORK WITH MINIMUM 6.0 R -VALVE FIBERGLASS DUCT WRAP INSULATION. ALL DUCTWORK, INCLUDING DIFFUSER SURFACES EXPOSED TO THE PLENUM, SHALL HAVE A SEALED VAPOR BARRIER FACE WITH ALL SEAMS TAPED VAPOR BARRIER TIGHT. ALL JOINTS WHERE PRE- INSULATED FLEX TIES TO DIFFUSERS AND DUCT MUST BE DOUBLE SEALED WITH THE INNER SEALED TO THE DIFFUSER OR SPIN -IN AND THE OUTER SEALED TO THE DIFFUSER AND DUCT INSULATION. ALL DUCTWORK SHALL BE SHEET METAL IN ACCORDANCE WITH SMACNA STANDARDS. DUCT - - -SIZES SHOWN ARE CLEAR INSIDE DIMENSIONS- - - - - -- -•-•-• -- - - -- -- - ALL MATERIALS AND INSTALLATIONS SHALL COMPLY WITH CHAPTER 5 OF THE INTERNATIONAL MECHANICAL CODE. GRILLES AND DIFFUSERS: GRILLES AND DIFFUSERS SHALL BE AS MANUFACTURED BY KREUGER, HART AND COOLEY, BARBERCOLMAN,.OR.TITUS. EACFLISTO.BE FITTED WITH A VOLUME DAMPER,(.OPP_OSED. TESTING AND BALANCING CERTIFIED (AABC OR•NABB) INDEPENDENT TESTING COMPANY TO TEST AND BALANCE SYSTEM TO CFM AS SPECIFIED. REPORT RESULTS TO TENANT AND ARCHITECT. GUARANTEE: A. EACH CONTRACTOR SHALL UNCONDITIONALLY GUARANTEE IN WRITING ALL MATERIALS, T AND WORKMANSHIP A PERIOD YEAR FROM OF ACCEPTANCE EQUIPMENT, RKMANSHIP FOR RIOD OF ONE Y OM DATE O CC Q OF OWNER. THE CONTRACTOR SHALL PROVIDE FREE SERVICE FOR ALL EQUIPMENT INVOLVED IN HIS CONTRACT DURING THIS GUARANTEE PERIOD. B. THE GUARANTEE SHALL INCLUDE RESTORATION OF ITS ORIGINAL CONDITION OF ALL ADJACENT WORK THAT MUST BE DISTURBED IN FULFILLING THIS GUARANTEE. C. ALL SUCH REPAIRS AND /OR REPLACEMENTS SHALL BE MADE WITHOUT DELAY, AND AT THE CONVENfENCE OF THE OWNER. SUBSTITUTIONS: A. APPROVALS OF SUBSTITUTIONS FOR "APPROVED EQUAL ", MUST BE IN WRITING AND SUBSTITUTION MUST BE APPROVED BEFORE INSTALLATION. INSTALLATION WITHOUT PRIOR APPROVAL MAY RESULT IN CONTRACTOR REMOVING SUBSTITUTION AND REPLACING IT WITH SPECIFIED ITEM AT HIS EXPENSE. B. APPROVAL MAY BE GIVEN BY ARCHITECT, ENGINEER OR OWNER. REMARKS WITH OPPOSED BLADE DAMPER WITH LOCKING QUADRANT VOLUME DAMPER. COORDINATE WITH ARCHITECT MOUNTING HEIGHT. CUSTOMER SUPPLIED RJ-45 JACK FOR E-STAT e-Stat G M TWO -WAY COMMUNICATING THERMOSTAT THERMOSTAT NOTES 1. THERMOSTAT (s) SHALL BE LIGHSTAT MODEL E-STAT, AB, 24 VAC, SOLID O ALL G EL E S SOLI TATS STATE, CHANGEOVER, MULTISTAGE HEAT /COOL, 2 -WAY COMMUNICATING THERMOSTAT._ 2. A REMOTE ROOM TEMPERATURE SENSOR AND SUPPLY AIR SENSOR COME STANDARD WITH EACH E-STAT. 3. THE E -STAT WILL RUN ON DEFAULT SETTINGS OF 68A HEAT/73A COOL UNTIL REMOTELY CONFIGURED BY CORPORA i E OFFICE. 4 INSTALLATION OF THE E- STAT.REQUIRES INDUSTRY STANDARD RJ-45 ETHERNET_.. .W CONNECTION TO LOCAL AREA NETWORK:.(AB PROVIDED BY THE CUSTOMER OR • • _ DESIGNATED THIRD PARTY). RJ-45 MUST -BE INSTALLED WITHIN 3 FT. BELOW ':'HE E -STAT THERMOSTAT AND TESTED TO VERIFY THAT IT IS ACTIVATED PRIOR TO THE INSTALLATION OF THE E -STAT THERMOSTAT. 5. ONE (1) 3 FT. CAT5e PATCH CABLE IS SUPPLIED TO CONNECT FROM E -STAT TO THE RJ -45 JACK 6. REQUIRED, BUT NOT INCLUDED, 8- CONDUCTOR #18 AWG WIRE FROM RTU TO E -STAT, 2- CONDUCTOR #18 AWG (NON - SHIELDED) WIRE FROM E -STAT TO REMOTE ROOM SENSOR, 2- CONDUCTOR #18 AWG (NON- SHIELDED) WIRE FROM E -STAT TO SUPPLY AIR SENSOR. 7. ONE (1) E -STAT ASSEMBLY IS REQUIRED FEACI- HVAC UNIT. 8. ALL NETWORK WIRING AND OUTLET(s) TO THE E- STAT(s) ARE THE RESPONSIBILITY OF THE CUSTOMER OR DESIGNATED THIRD PARTY REPRESENTATIVE. LIGHTSTAT SUPPLIED CAT5/5e, 3 FT. PATCH CABLE i ETHERNET SWITCH/HUB CUSTOMER SUPPLIED CAT5 /5e WIRING FROM PATCH PANEL TO REMOTE m RJ-45 JACK (LESS THAN IL 320 FT.) CUSTOMER SUPPLIED NETWORK EQUIPMENT E-STAT DIAGRAM j NTS LIGHTSTAT CONTACT INFO. 22 W. WEST HILL ROAD BARKHAMSTED, CT 06063 Ph. - 860- 292 -2444 ex "0" Fax - 860 - 738 -4123 E -MAIL - orders @Iightstat.com CUSTOMER SUPPLIED CAT5 /5e PATCH CABLE ENABLE COMMUNICATIONS PORT AS REQUIRED EXPIRES DEC 2 0 2009 29 TOTAL LOAD 30 SENSIBLE HEAT FACTOR 31 SUPPLYAIRA T(° F.) 29 SUPPLY AIR QUANTITY (CFM) 30 CFM /SCI. FT: . �31 O.S.A. SENSIBLE HEAT r 0.87 32 O.S.A. LATENT HEAT 054 33 34 34 36 37 FANS (HP) ROOM GRAND TOTAL LOAD ROOM GRAND TOTAL CFM 45,851 0.81 20 1,714 0.81 0 _.. 0 0 '0 1 2,545 48,396 0.87 0.54 0.97 20 366 1.08 0 0 8,156 0 ,545 10,701 DIVERSIFIED: ARCHiTECT11RAL. CONSULTING - ' 190i. Newport Blvd. suite #300 = Costa Mesa, Ca. . '; - Phc 949.698:1400 .: • Fax 949:698.1433 . =: This drawing and the design shams are the property of Little Diaersified Architectural Consulting. The reproduction, copying or other use of this draping without their written consent is prohibited and any infringement 22¢11 be subject to legal action. dp CLIENT NAM!, -- -. - _PR07ECTN PRINCIPAL IN CHARGE HHH PROJECT MANAGER EM DRAGON BY SG /GM NO www.littleonline.com ;' 4 C tfr ' r DUNGAIIEES Ton :alsG3Q To D2E a © Little 2007 DON PENN CONSULTING ENGINEER 635 WESTPORT PARKWAY, SUITE 300 GRAPEVINE, TEXAS 76051 817 -410 -2858 FAX 817 -251 -8411 co co 0 co co co 0,0 Ce C .1 w LLI F L m cal O REASON DATE GENERAL NOTES, SPECIFICATIONS, CALCULATIONS, AND DETAILS 0 12/21/07 625-4089-01 ,ISSUE'.DA14 5HEETNO;.c - M2.0 iii "...: _ TI,U1CM7