Loading...
HomeMy WebLinkAboutPermit M08-026 - 730 APE730 APE 730 ANDOVER PK E M08 -026 Parcel No.: 2623049095 Address: Suite No: 730 ANDOVER PK E TUKW Tenant: Name: 730 APE Address: 730 ANDOVER PK E , TUKVVILA WA Owner: Name: 790 ANDOVER LLC Address: PO BOX 287 , MEDINA WA Contact Person: Name: KEVIN TAKAYESU Address: 3602 S PINE ST , TACOMA WA Value of Mechanical: $25,000.00 Type of Fire Protection: Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended/Wall/Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat /Refrig /Cooling System.... 0 Air Handling Unit <10,000 CFM 1 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial/Industrial 0 doc: IMC -10/06 City* Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Contractor: Name: AIR SYSTEMS ENGINEERING Address: 909 SOUTH 28TH STREET , TACOMA, WA Contractor License No: AIRSYE *229KN DESCRIPTION OF WORK: INSTALLATION OF 25 TON GAS /ELECTRIC ROOFTOP UNIT MECHANICAL PERMIT EQUIPMENT TYPE AND OUANTITY * *continued on next page ** M08 -026 Permit Number: M08 -026 Issue Date: 02/26/2008 Permit Expires On: 08/24/2008 Phone: Phone: 253 977 -2588 Phone: 206 628 -9484 Expiration Date: 02/01/2010 Fees Collected: $442.45 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 02 -26 -2008 Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied Signature: doc: IMC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us a • Permit Number: M08 -026 Issue Date: 02/26/2008 Permit Expires On: 08/24/2008 Date: `— 1/ ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perfo , -.:• e of �� tgsign and obtain this mechanical permit. Date: - -01.- Print Name: lL w /6t T (LA/ e3 L This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -026 Printed: 02 -26 -2008 Parcel No.: 2623049095 Address: 730 ANDOVER PK E TUKW Suite No: Tenant: 730 APE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 5: Readily accessible access to roof mounted equipment is required. PERMIT CONDITIONS • Permit Number: M08 -026 Status: ISSUED Applied Date: 02/05/2008 Issue Date: 02/26/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the doc: Cond -10/06 M08 -026 Printed: 02 -26 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 16: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 18: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 19: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 20: Local U.L. central station supervision is required. (City Ordinance #2051) 21: The installation of wiring and equipment shall be in accordance with N.F.P.A. 70, Article 760, Fire Protective Signaling Systems. (NFPA 72- 1.3.3) 22: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 23: To schedule all construction fire - related inspections send an e -mail to fireinsprequest @ci.tukwila.wa.us. Include your name, telephone number, permit number, project name and address and type of inspection requested. 24: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 25: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond - 10/06 * *continued on next page ** M08 -026 Printed: 02 -26 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: /zGv /F, 4.1 q doc: Cond -10/06 M08 -026 Date: e OF" ordinances governing or local laws regulating Printed: 02 -26 -2008 SITE LOCATION Site Address: 7.J(i XHI °Oleo' Pam K ,' -sf- Tenant Name: 73 U /f ...Ave It / Property Owners Name: IL C N L /N / N f r Mailing Address: J'a "f A .' 7 Name: 7;, /0aresto Mailing Address: Si C S. 1 i e Si E -Mail Address: 1Z e v fel f G se i, as Company Name: Mailing Address: Contact Person: E -Mail Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 South'center Blvd., Suite 100 Tukwila, WA 98188 hup '104 ci.tttlot iki wa trs Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** it Sys leo^ s 1r5 .7‘ 0 2 S. /" c T4 ICA/ es c. Kevt..+ - c sc, . G.,S Company Name: P4 JA get q /J Mailing Address: 740 2 .5 r/ / C ‘f Contact Person: teet// h e .sH E -Mail Address: eG,vi H f aP a5cr - c.t.iw Q:\Applications\Forms- Applications On Line \3 -2006 - Permit Applicatiion.doc Revised: 9 -2006 bh No. Building Permit No. Mechanical Permit No. Plumbing /Gas Permit No., Public Works Per Project (Fora) e use only) King Co Assessor's Tax No.: a 6..1 3 04( 9 //S 2 c Contractor Registration Number: AT e S Y e Du. y iew Contact Person: E -Mail Address: Suite Number: New Tenant: City Floor: ❑ Yes []:.No LJA State 7503 Zip ho do we contact when you is ready to be issued CONTACT PERSON - Day Telephone: .?r 3 7 7 - a Se, /Ace .a UN 9ry03 Cit State Zip Fax Number: .?.t"„3 - 313 - e 377 GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping Tito •••• 1.1A Yr'/03 City State Zip Day Telephone: ;L 7 - 577-.2-ref' Fax Number: ) S .3 - 373 ' L 337 Expiration Date: %.01 6A#d'i ? [S /, d` J JO us t b wet stam ped Record ARCHITECT OF RECORD - A Architect o Company Name: Mailing Address: city Day Telephone: Fax Number: State Z p ENGINEER OF RECORD -' pl to d by Eng Record Tu CGr• -► 4 City Day Telephone: Fax Number: tJ/4 Yvay State Zip , l$3 -3L1- 633 Page 1 of 6 BUILDING PERMIT INFORMATION 206- 431 -3670 Valuation of Project (contractor's bid price): $ Existing Building Valuation: $ Scope of Work (please provide detailed informai't, ) _ Will there be new rack storage? ❑ Yes Q: 'Applications'\Forms- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh [. No If yes, a separate permit and plan submittal will be required. et Floor 2n Floor 3rd Floor Floors thru Basemen Accessory Structure* Attar Detached Garag Attached Carport Detached Carport Covered Deck Uncovered Deck Proviid All Building Areas fun Square Footage Below PLANNING DIVISION: Single family building footprint *For an Accessory dwelling, p Lot Area (sq ft): *Provide docume FIRE PROT " TION/HAZARDOUS MATERIALS: Addition to Existing Structure Type of Construction per IBC a of the foundation of all structures, plus any decks ov• 18 inches and overhangs greater than 18 inches) ide the following: Floor area of principal dwelling: Floor area of accessory dwelling: ion that shows that the principal owner lives in one of the dwellings as his or her primary residence. Type of Occupancy, per IBC Number of Parking Sta . Provided: Standard: Compact: Handicap: Will there be a than in use? ❑ Yes ❑ No If "yes ", explain: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System -- For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall /Floor Mounted Heater Ventilation System Wood /Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat /Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator - Comm /Ind MECHANICAL PER IT MECHANICAL CONTRACTOR INFORMATION Company Name: ,4/ r Sick ‘44..c Fr e c e/%') Mailing Address: 3 ‘na S fii c S/ Ta CaPvt 4 Contact Person: /Le ga E -Mail Address: 1e C u('- t (7 c. .se / . !,J L Q:\Applications \Forms - Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh INFORMATION - 206-431 -3670 Contractor Registration Number: ,4 ..rR 3 V E* a ay /ClV Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... Q' Replacement .... ❑ Indicate type of mechanical work being installed and the quantity below: 4)/ V90 City State Zip Day Telephone: .7.S S'72 -1 YP/ Fax Number: .2,5"..T - _ST; - ,rS7 Expiration Date: ,S /10 / .2 OU y Valuation of Mechanical work (contractor's bid price): $ .2.; COO Scope of Work (please provide detailed information ): // -f Tory �4s �iC /uf. ,� ,Q oe.k /-tJr l Fuel Type: Electric ❑ Gas Other: Page 4 of 6 PUBLIC WORKS PERMIT INFORMATION - 433 - 0179 Scope of Work (please provide detailed information): Water District ❑ ...Tukwila ❑ ...Water Availability Provi Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate re tic System: On -site Septic System - For on -site Submitted with Application (mark boxes ❑ ...Civil Plans (Maximum Paper Size - 2 ❑ ...Technical Information Report (Storm Drai ❑ ...Bond ❑ .. Insurance Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut ❑ ...Total Fill ❑ ...Sanitar y Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Wa ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension ...Public ❑ ...Water Main Extension . .Public FINANCE INFORMAT Water Meter Refund/Billing: Name: Mailing Address: cubic yards cubic yards Please refer to Public Works Bulletin #1 for fees and estimate sheet. ...Water District #125 ... ValVue ❑ .. Renton Sewer Availability Provided tic system, provide 2 copies of a current septic design app .,.Y by King County Health Department. Q:\Applications\Fonna- Application On Lmo\3 -2006 - Permit Application.doc Revised, 9 -2006 bh Call before you Dig: 1 -800- 424 -5555 ❑ .. Highline ch apply): 34 ") e) ❑ .. Geotechnical Re asement(s) ❑ .. Maintenance ❑ .. Aban Septic Tank ❑ .. Cu ut ement Cut ooped Fire Line ❑..P WO # WO # WO# Private Private f -way Use - Profit for less than 72 hours t -of -way Use - Potential Disturbance .. Work in Flood Zone .. Storm Drainage Number of Public Fire Hydrant(s) ❑ ...Sewa Treatment ❑ .. Renton ❑ .. Seattle ❑ ...Traffic Impact Analysis eement(s) ❑ ...Hold Harmless - (SAO) ❑ ...Hold Harmless - (ROW) ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ - ..Dedu ^•Water Meter Size Fire Line Size at Prop Line ❑ ...Water ❑ ...Sewer Monthl Servic. .11lin_ to: Name: Mailing Address: Day Telephone: City City State Zip Day Telephone: State Zip Page 3 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Signature: Print Name: Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER li ti T /4yei Mailing Address: 36a .t .S / /rt I Date Application Accepted: c1-- l�si� Q:\Applications\Portns- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 Oh S/ Day Telephone: 7 � City Date: — Ocy Ar5/0 State Zip Date Application Expires: ®$I Staff Initials: Page 6 of 6 Fixture Type: Bathtub or combination bath /shower Bidet Clot domestic hes washe Dental unit, cuspidor Dishwasher, domestic, with independent drain Building sewer or trailer park sewer Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Qty Lavatory PLUMBING AND GAS PIPING PERMIT INFORMATION PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: H ir 5rf4t f � r` f /In e, Mailing Address: 3[!71 S "'et( fi Contact Person: iL Q.i/I v+ E -Mail Address: /lCa/t r► G / • L,/ Contractor Registratio umber: AT RS }YE #.1.) 9 Y N Valuation of Plumbing work ontractor's bid price): $ Valuation of Gas Piping work tractor's bid price): $ 900 Scope of Work (please provide det. -d information): D ) "pr /, ... /e i . R r i uki f Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Indicate type of plumbing fixtures and/or gas piping outlets 'ng i, alled and the quantity below: Fixture Type; Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head P Rain water sy m — per drain (insids . ilding) Repair or eration of water piping . /or water treating equip • nt Q:\Applications\Fomms- Applications On Line \3 -2006 - Permit Application :doc Revised: 9 -2006 bh Fixture Type: Wash fountain Sin ceptor, indirect e Urina Water Water heat vent Repair or altera of drainage or ve piping 14 Ga.8" A City Day Telephone: Fax Number: Sewer: set Expiration Date: .l d /or Q SJ.- f72 -Syr/ ? s5 - 3i3 - <J> 7 /d-•. Fixture Type: Gas piping outlets CJ /a yefyo.3 State Zip v /p Additional medical gas inlets /outlets — six or more Medical gas piping system serving one to five inlets /outlets for specific gas Qty Page 5 of 6 Doc: RFC:SFTS -f A RECEIPT NO R08 -00315 SET TRANSACTIONS: Set Member Amount ACCOUNT ITEM LIST: Description • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http:/lwww.ci.tukwila.wa.us Initials: JEM Payment Date: 02/05/2008 User ID: 1165 Payee: AIR SYSTEMS ENGINEERING INC. SET ID: 5000000950 SET NAME: Tmp set/Initialized Activities EL08 -115 62.00 M08 -026 442.45 PGO8 -029 92.00 TOTAL: 596.45 TRANSACTION LIST: Type Method Description Amount Payment Check 451295 596.45 TOTAL: 596.45 ELECTRICAL PERMIT - NONR GAS - NONRES MECHANICAL - NONRES PLAN CHECK - NONRES SET RECEIPT Total Payment: 596.45 Account Code Current Pmts 000.322.101.00.0 62.00 000.322.103.00.0 92.00 000/322.100 359.96 000/345.830 82.49 TOTAL: 596.45 8099 02/05 9710 TOTAL 596.45 Project: 73) A f Type of Inspection: Sir)o h&- --5/71/1/.1 44/4/ Address: 7 3 v ,4 /' // e Date Called: Special Instructions: , i fil,F1 P7 2 F ,4 7 v Date Wanted: — 3 v-- /0 p.m. Requester: Phone No: X253 —4 _3 v/e INSPECTION NO. INSPECTION RECORD Retain a copy with permit 42a8 =626 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: 5„4J tc¢ Sht4 eilen,Ati - frippfiv,C - rip 01 Approved per applicable codes. Corrections required prior to approval. a �a .00 REINSPECTION FEE EQUIRED. P, for to inspection, fee must be id at 6300 Southcenter Bl •., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: 730 Ps- Pt._ Type of Inspection: 7 1NJ ft l_ Address: 73 A-P Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone No: AS 5-Li 05 - 3 o 1 C roved per applicable codes. Corrections required prior to approval. COMMENTS: 0 9 molt, kW--. •,.) ;AI of ,� ), --ck s cm 4 e v i' ll 7k P ., (� 1, - 1 i INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 1 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit Pio PERMIT NO. Insp3 tor: $69.00 REI SP CTION F REOU ED. Prior to inspection, fee must be p - id at 6300 Southcenter Blvd., Sete 100. Call to schedule reinspection. Re, -ipt No.: Date: 'Date: Project: Type of spection: Address: 73c) /2"/‹.E..._ Date Cal led f Special Instructions: / ` Date Wanted: c °'"'' EJ — —65 iv.m. Requester: Phone No: a5 -4 /as - 7t42 7 INSPECTION RECORD 4 ' G • Retain a copy with permit INSPECT ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 14 " 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. 7 COMMENTS: Inspector: f Date: v - -7 --a I ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: IDate: COMMENTS: Type of Inspection: ;- vA f/ 7 - - Address: 77-2, C; /4/ Suite #: Contact Person: Special Instructions: Phone No.: Hood & Duct: / Monitor: ;`' r * Permits: .' 1 / Project: Cc , ,, t j f , ; i, ;t. 5 Type of Inspection: ;- vA f/ 7 - - Address: 77-2, C; /4/ Suite #: Contact Person: Special Instructions: Phone No.: Hood & Duct: Needs Shift Inspection: ;" Sprinklers: Fire Alarm: I Hood & Duct: / Monitor: ;`' Pre -Fire: Permits: Occupancy Type: / INSPECTION NUMBER Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT • PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Word /Inspection Record Form.Doc 1/13/06 Corrections required prior to approval. Inspector: Y r Date: Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 C T E,■GINEIERING Structural Engineers FILE COPY Permit ti PLLC Structural Calculations 730 Andover Park E. Roof Top Unit Mechanical Contractor: Air Systems Engineering Project Engineer: Rick Hudson, P.E. `1 ;t 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285- 4512(V) (206) 285- 0618(F) jrai@ctengineering.com r L V _ • _... r . • 1 CODE CC' AP L{° 6bVd i Cl/ Of R. L• ,!- 1 RECEIVED CITY OF TUKWILA FEB 'Q5 2008 PERMIT CENTER Mod -(00 I N E;E R I N` Project: Client: Structural Engineers 1 r-f...) A cii6k1S2AE P L C e ve kke- P( + to s o, n o5�z Date: '") ?'(1;) l 6 Page Number: GGUCII 111 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512 FAX: (206) 285-0618 kisILL) rock 4,(1 - O 2 ft r -i-e = zA (C 24 ) -2- ,(al < ( )Lip) y 1 � (4x tl S { '► Ff r\z s S • )05( -wt C2 Si -ruG, olc Y 44)CLcO - 1,1 >< 2 - 1 x \ ontaar ebA'rwAA.. . 4 x 1(o I' ((lel s kyt.v" 4, Y = • 3 x 2 'Co (,0 2 7 00 H z� 10S 1� L� w' @z4 e 8' s e ve, Ng...LefZ- I I wt tr S act 4 1, , o 1,•c J, 0 2 .0 2. < . 0 .0 1 2 . o tO 34,4 11605 2 < 1,5Sx 2�}y2 = 7Si `b x 1 2 13,(04 < I,t5 x1ro�� 1, 1 ' x {5 �� I 7.31 MK = 2\el.q- k. C) y P1 C m cn cn Oz l= w0 m — m O 0 v m O N CO M N = o' D m (J4 O co EXISTING 4X16 at 8' OC ue DUSTIN 3 EXISTING EXISTNG GIB G'B PARTIAL ROOF FRAMING PLAN NTS EXISTING GLB EXISTING EXISTING GL EXISTING GLB �. NEW 1i X 11i TIMBERSTAND EACH SIDE OF EXISTING PURLIN AT THIS ONE LOCATION NEW ROOF TOP UNIT NOTE 1i X 11i TIMBERSTAND E= 1,550,000 psi FB =2325 psi 0 --3 E r 0 0 o N N co ol al o 0) al 0 N CJ4 0 D z 0 0 < P1 2J > 2J P1 Oz I 2 co o^'m omO . O N c� N = CO 0 > m I m co 0 co 3 "0 @ 2 4 PENE BELO g LAG SCREW "OC TRATE BEAM W 4" MIN v 7" MIN L 1. 9 UNIT WT = 2700 POUNDS UNIT NOT TO SCALE 0 3/4"0 M.B. @ 24 "OC 2 - "0x3" LAGS @ 5 OC L 4x4xY8 x 1' -7" W /3— 3/4"0 M.B. © 8 "OC #12 TEK SORE 18 "OC @ UNIT CURB CURB BY MECH CONTRACTOR m 0 SEE SE DETAIL 4x10 BLOCKI W /U46 HANG EA. END PLACE CURB OVER PURLIN OR PROVIDE W /HANGER. 1 x 111/4 EACH SIDE 1 /2 8" 8" ,11" SFAT DFTAU SECTION A DO NOT SCALE TO A N EXISTING WOOD PURLIN AT 8' OC 5 0 T ELOW G R - - -- B NG OR GLB 4X10 MICROLAM FULL LENGTH. MINIMUM FB =2600 PSI. March 25, 2010 Department of Community Development Douglas Crawford Air Systems Engineering Inc. 3602 S Pine St Tacoma WA 98409 City of Tu �:: RE: Request for Extension #3 Mechanical Permit No. M08 -026 730 APE — 730 Andover Pk E Dear Mr. Crawford, This letter is in response to your written request for an extension to Permit Number M08 -026. The Building Official has reviewed your letter and considered your request to extend the above referenced permit. The City of Tukwila Building Division will be extending your permits an additional 180 days from the date of expiration, through September 20, 2010, as requested. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, %- Je 'fer Marshall $e 't Technician File: Permit No. M08 -026 W:\Permit Center\Extension Letters \Permits\2008\M08 -026 Permit Extension #3.doc Page 1 of 1 jem Jim Haggerton, Mayor Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 AIR SYSTEMS ENGINEERING INC: AIR CONDITIONING SHEET METAL REFRIGERATION ELECTRICAL PROFESSIONAL ENGINEERS SERVICE & MAINTENANCE BUILDING AUTOMATION SYSTEMS Bill Rarnbo City of Tukwila, DPD 6300 Southcenter Blvd., Ste. #100 Tukwila, WA 98188 Re: Permit Extension Request #3 Permit No. M08 -026 Dear Bill: Please accept our request to extend permit M08 -026 for an additional 90 days. Our mechanical work for this project is complete. However, we cannot order our final inspection at this time, as inspections by the Fire Department are still pending. Should you have any questions, please contact me at 253 -572 -9484. D,dl glo /16 da-e-6 RECENED 6 5/29.00 MAR 18 2010 Are you comfortable? March 17, 2010 Sincerely glas Crawfo ngineering Department Manager PERMIT CENTER *. ottli 3602 South Pine Street • Tacoma, WA 98409 • Tacoma: 253 - 572 -9484 • Seattle: 206 - 628 -9484 • Fax: 253 - 383 -6337 • www.asei.ws • AIRSYE *229KN A Comfort Systems USA Company JESSICA BRUCE 3602 S PINE ST TACOMA WA 98403 RE: Permit No. M08 -026 730 ANDOVER PK E TUKW Dear Permit Holder: City f Tu 7 Jim Haggerton, Mayor In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 03/23/2010. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 03/23/2010, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerel Bill Rambo Permit Technician epartment of Community Development Jack Pace, Director ',,,z,12,2 q,fi,--- File: Permit File No. M08 -026 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 JESSICA BRUCE 3602 S PINE ST TACOMA WA 98403 RE: Permit No. M08 - 026 730 ANDOVER PK E TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 08/19/2009. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period. Sincerely, -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 08/19/2009, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Bill Rambo Permit Technician File: Permit File No. M08 -026 Department of Community Development Jim Haggerton, Mayor Jack Pace, Director 6 .cm,throntar Rnulevard_ Suite #100 • Tukwila. Washineton 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 I' .si January 15, 2009 Douglas Crawford Air Systems Engineering Inc. 3602 S Pine St Tacoma WA 98409 RE: Request for Extension #2 Mechanical Permit No. M08 -026 Plumbing/Gas Piping Permit No. PG08 -029 Electrical Permit No. EL08 -115 730 APE — 730 Andover Pk E Dear Mr. Crawford, This letter is in response to your written request for an extension to Permit Numbers M08 -026, PG08 -029, and EL08 -115. The Building Official has reviewed your letter and considered your request to extend the above referenced permits. The City of Tukwila Building Division will be extending your permits an additional 180 days from the date of expiration (through August 19, 2009) as requested. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, t ifer Marshall it Technician City of of Tukwila Department of Community Development Jack Pace, Director File: Permit No. M08 -026, PG08 -029, & EL08-1 15 P:\Permit Center\Extension Letters\Pemtits\2008\M08 -026+ Permit Extension #2.doc Page 1 of 1 jem Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 a Tukwila, Washington 98188 • Phone: 206 - 431 -3670 0 Fax: 206 - 431 -3665 AIR CONDITIONING SHEET METAL REFRIGERATION ELECTRICAL PROFESSIONAL ENGINEERS SERVICE & MAINTENANCE BUILDING AUTOMATION SYSTEMS Dear Jennifer, RECEWED JAN 0 6 2009 COMMUNITY DEVELOPME=NT Jennifer Marshall Permit Technician City of Tukwila 6300 South Center Boulevard, Suite 100 Tukwila, Washington 98188 January 5, 2009 Re: Permits Extension Request Permit No's PG08 -029 and EL 08115 ' Apt — 02.(e Site address 730 Andover Park E., Tukwila We are hereby requesting time extensions beyond 2/20/2009 for the above referenced permit numbers. This due to unforeseen delays in construction partly due to the tenant schedule and weather. We fully expect the work to move forward in April 2009 when the weather is more temperate as the gas service will be shut down for a time during the construction. Our goal is to minimize minimal impacts to our customer's operations. Thankyou f• the notification. If you have questions please call 253 -572- 9484. Sincerel OA !/ gas Crawfo ineering Department Manager e 9, .10 4,44-d e 4 a1-i4-O9 Are you comfortable? r � �*lo91 3602 South Pine Street • Tacoma. WA 98409 • Tacoma: 253 - 572 -9484 • Seattle: 206- 628 -9484 • Fax: 253 - 383 -6337 • www.asei.ws August 11, 2008 Kevin Takayesu Air Systems Engineering Inc. 3602 S Pine St Tacoma WA 98409 RE: Request for Extension Mechanical Permit No:408 -026 Plumbing/Gas Piping Permit No. PG08 -029 Electrical Permit No. EL08 -115 730 APE — 730 Andover Pk E Dear Mr. Takayesu, This letter is in response to your written request for an extension to Permit Numbers M08 -026, PG08 -029, and EL08 -115. The Building Official has reviewed your letter and considered your request to extend the above referenced permits. The City of Tukwila Building Division will be extending your permits an additional 180 days from the date of expiration (through February 20, 2009) as requested. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, Pay fifer Marshall it Technician City of Tukwila Department of Community Development Jack Pace, Director File: Permit No. M08 -026, PG08 -029, & EL08 -115 P:\Pemrit Center\Extension Letters\Permits\2008W08 -026+ Permit Extension.doc Page 1 of 1 jem Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 AIR SYSTEMS ENGINEERING INC. AIR CONDITIONING SHEET METAL REFRIGERATION ELECTRICAL PROFESSIONAL ENGINEERS SERVICE & MAINTENANCE BUILDING AUTOMATION SYSTEMS City of Tukwila Department of Community Development 6300 Southcenter Blvd Ste: 100 Tukwila, WA 98188 Re: Permit No. M08 -026, PG08 -029, EL08 -115 1191 ANDOVER PK W TUKW Dear Jennifer Marshall: This is an extension request for M07 -291, PG07 =348, EL07 =805. The reason for the extension is we are waiting on the owner to complete his part of the construction before we can do our work. Please let me know if there is anything else you will need. Od• is /OD 124/ 4" *Teo reeemts 07/Er Are you comfortable? AIRSYE'229KN July 22, 2008 RECEIVED 1JUL 2 S 2008 Kevin Takayesu Project Engineer � 60n 617-4-11�a 6 P 62-I 3602 South Pine Street • Tacoma, WA 98409 • Tacoma: 253 -572 -9484 • Seattle: 206 - 628 -9484 • Fax: 253 - 383 -6337 • www.asei.ws 07 -15 -2008 KEVIN TAKAYESU 3602 S PINE ST TACOMA WA 98403 RE: Permit No. M08 -026 730 ANDOVER PK E TUKW Dear Permit Holder: Cif off'Tukwila Department of Community Development Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code, every permit issued by the Building Division under the provisions of the code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit issuance, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or fmal inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code does allow the Building Official to approve one extension of time for an additional period not exceeding 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 08/24/2008 , your permit will become null and void and any further work on the project will require a new permit application and associated fees. Thank you for your cooperation in this matter. Sincerely, er Marshall Pe?tfiit Technician xc: Permit File No. M08 -026 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: M08 -026 DATE: 02 -05 -08 PROJECT NAME: 730 APE SITE ADDRESS: 730 ANDOVER PK E X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: 2 Buildi g Division Public Works Comments: Please Route Documents routing slip.doc 2 -28 -02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 1� TUES/THURS ROUTING: REVIEWER'S INITIALS: Fire Prevention Structural Incomplete Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: Structural Review Required APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: Planning Division n Permit Coordinator n DUE DATE: 02-07-08 Not Applicable No further Review Required DATE: Not Approved (attach comments) DATE: n DUE DATE: 03-06-08 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License AIRSYE *229KN Licensee Name AIR SYSTEMS ENGINEERING INC Licensee Type CONSTRUCTION CONTRACTOR UBI 600099211 Ind. Ins. Account Id Business Type CORPORATION Address 1 3602 S PINE ST Address 2 City TACOMA County PIERCE State WA Zip 984098197 Phone 2535729484 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 5/15/1978 Expiration Date 2/1/2010 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date ANDERSON, CURTIS M 01/01/1980 ANDERSON, LORINE 01/01/1980 Look Up a Contractor, Electri or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. TRAVELERS S Bond Information Bond #7 Bond Company Name VIGILANT INS CO Bond Account Number 82138376 Effective Date 02/01/2008 Expiration Date Until Cancelled Cancel Date Impaired Date Bond Amount $12,000.00 Received Date 02/04/2008 Page 1 of 3 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= AIRSYE *229KN 02/26/2008 N co r o co FILE C PY Permit Ho. ' SEPARATE T REQUIRED FOR: ❑ Mechanical [Electrical Plumbing Gas Piping City of Tukwila LBI.`'lILDIN DIVISION Filar review approval Is subject to errors and omissio Approval of construction documents d s> t Rood the violation of any adopted�na� ord is act<nod�edg of approved Field Copy an d City of Tukwila BUILDING! DIVISION No changes of work , o,,i111 , ° i . Tukwila Eaila.�g iir� a NOTE: Revisions will o taro <a not ° plat slabmiitai and may include ad itionat plan revie', VAC 1/16" = 1' oor P C E Piping Calculations Total production length of pipe is 105 feet Max gas demand for: AC -1 outlet = 400,000 Btu per hour = 400 cubic feet per hour or 400 cfh 1.000 Btu per cubic foot Using Table 402.3 In the IFGC AC -1 outlet, supplying 400 cfh requires at least a 1.5 pipe INSULATION AROUND ROOF CURB BY OTHERS RUN ROOFING TO TOP OF CURB NAILER ALL AROUND CANT STRIP BY OTHERS ROOF DECK FACTORY ROOF CURB BOTTOM CHORD OF GLB 7' 24x24 SR -1 (TYP OF 4) FLUSH MOUNT ON DUCT DROP ROOFTOP UNIT AC - 1 Detail COVER W/ Y2" BIRDSCREEN Not to scale POWER EXHAUST ECONOMIZER G.C. OR OWNER TO SHIM LEVEL BASE FOR ROOF CURB 60/24 OPENING IN SIDE OF DUCT GENERAL NOTES 1. All duct sizes shown are clear inside dimensions. 2. All duct gauges and supports per 2006 IMC. 3. ASEI to air balance all systems to within 0% of design airflow upon project completion. 4. Insulate supply and return duct work per Washington State Energy Code. See Plan for details. 2" liner & wrap shall insulate to R -7 minimum. 5. All ducts to be sealed per the Washington State Energy Code. COORDINATION NOTES General Contractor 1 General Contractor to cut and provide openings for all rooftop, ceiling, floor, and wall penetrations, including weatherproof sealing. ASEI to provide size and location. 2. General Contractor to provide framed openings where required for all mechanical penetrations, including headers if required. General Contractor to verify penetration locations with ASEI before framing openings. 3. General Contractor to provide all demolition, patching and painting as required for mechanical work. 4. General Contractor to spread roof and floor trusses/joists to accommodate mechanical work. 5. General Contractor to provide service access per code to all mechanical equipment. 6. General Contractor to level all factory curbs provided by ASEI, provide all cant strips and curb insulation, and seal against leaks. 7. General Contractor to provide structure for mounting and hanging members of mechanical equipment. 8. Fire damper access doors on duct work to be installed by ASEI. Access to duct work through walls and ceilings by General Contractor. Electrical Contractor 1. Electrical Contractor to provide all electrical connections, disconnects, and motor starters for mechanical equipment. 2. Electrical Contractor to verify equipment sizes, loads and locations with ASEI mechanical plan and with field conditions. 3. Electrical Contractor to provide 120v service outlet within 25 feet of each piece of mechanical equipment. 4. ASEI to install all 24 volt low voltage wiring for thermostats. 5. Electrical Contractor to install all line voltage wiring and conduit. COMPLETION As -Built Record Drawings 1. Provide record drawings with minimum information specified in WSEC 1416.1 to Owner within 90 days of system acceptance. O&M Manuals 1. Provide Operating and Maintenance Manuals with minimum information specified in WSEC 1416.2 to Owner. Systems Balancing 1. Provide a written balancing report documenting testing and balancing of air and hydronic systems as specified in WSEC 1416.3 to Owner. Systems Commissioning 1. All HVAC control systems shall be tested in accordance with WSEC 1416.4.1 and 1416.4.2. 2. For all HVAC units, verify that thermostat activates heating mode, cooling mode, for all available stages, and verify that fan is set to run during all occupied hours. Verify initial programming of thermostat. Verify unit operation per ASEI Start and Test Report. 3. For all HVAC units`<`WithF *Ironic heating ot cooling, verify that thermostat activates control valve. Verify that central plant controls maintain loop water within specified set points. 4. For all HVAC units with economizers, verify that system controls activate economizer dampers when outdoor setpoint makes free cooling available, and that dampers modulate in conjunction with mechanical cooling staging per WSEC 1413. 5. A Preliminary Commissioning Report shall be prepared, with minimum information specified in WSEC 1416.4.2.2.1. 6. A Final Commissioning Report per WSEC 1416.4.2.2.2 shall be prepared and filed with the Owner. SCOPE OF WORK 1. Furnish and Install 25 Ton Gas /Electric Rooftop Unit. 2. Remove and dispose of the existing equipment. 3. Perform system startup & test. SCALE: N.T.S. VICI \ITY fvAP S 180th St RECEIVED CITY OF TUKWIIA FEB U5 Z008 PERMIT CENTER WIRES 12/27 /Oa REVISIONS L LU IHUI f- _ r - 1 - -I L J SPA CH 1 30 UNIT HEATERS TO BE REMOVED- r - -1 L J S. Ft' "L NEW AC -1 ON ROOF C TRANE YCD300B4HAH 25 TON GAS HEAT /E COOLING UNIT; 460V MCA 60; MFS 70. COOLING 290,000 BTUH, HEATI FIRST STAGE INPUT: SECOND STAGE INPU MIN OSA 2625 CFM 2" PLEATED AIR FILT. (4) 20x20, (4) 20x2' FURNISH WITH FACTO CURB, ECONOMIZER, EXHAUST. OP. WT. 2, EC 3PH; EER 9.7; G AFUE 80; 600 MBH; : 400 MBH; RS: "Y ROOF POWER . 95 LBS. 66/16 +1 RETURN DROP CORNER WEIGHT DESIGNATION 62/22 +1 "L TRANSITIONS TO 38/38 +1" L SUPPLY DRO POINT OF CONNECTION TO EXISTING GAS PIPE" EXISTING 1 1/2 "0 �� B _ _ �....._� � 11/20 0 • 1 1' 1 BALANCE !I 1, ► 2 :. 6,000 CFM 24x24 TITUS 300RS DOUBLE DEFLECTION SIDEWALL GRILLE (NO OBD) 0° BLADE DEFL. 2500 CFM (TYP OF 4) TB8220U1003 PROGRAMMABLE TBACK 5 DEGREE DEP I U' -, EXISTING 2 1/2 "0 L I i8 IN - I •I , �!? _ HONEYWELL SEVEN DAY W/ NIGHT S el * CAPABLE 0 -r �1 " ■ I ■ ■ -r SCHEDULES DAYS A WE :K FOR SEVEN I - I, 4 6:4, �0'��O«(O?O?O«:O"��0?O:�O N co r o co FILE C PY Permit Ho. ' SEPARATE T REQUIRED FOR: ❑ Mechanical [Electrical Plumbing Gas Piping City of Tukwila LBI.`'lILDIN DIVISION Filar review approval Is subject to errors and omissio Approval of construction documents d s> t Rood the violation of any adopted�na� ord is act<nod�edg of approved Field Copy an d City of Tukwila BUILDING! DIVISION No changes of work , o,,i111 , ° i . Tukwila Eaila.�g iir� a NOTE: Revisions will o taro <a not ° plat slabmiitai and may include ad itionat plan revie', VAC 1/16" = 1' oor P C E Piping Calculations Total production length of pipe is 105 feet Max gas demand for: AC -1 outlet = 400,000 Btu per hour = 400 cubic feet per hour or 400 cfh 1.000 Btu per cubic foot Using Table 402.3 In the IFGC AC -1 outlet, supplying 400 cfh requires at least a 1.5 pipe INSULATION AROUND ROOF CURB BY OTHERS RUN ROOFING TO TOP OF CURB NAILER ALL AROUND CANT STRIP BY OTHERS ROOF DECK FACTORY ROOF CURB BOTTOM CHORD OF GLB 7' 24x24 SR -1 (TYP OF 4) FLUSH MOUNT ON DUCT DROP ROOFTOP UNIT AC - 1 Detail COVER W/ Y2" BIRDSCREEN Not to scale POWER EXHAUST ECONOMIZER G.C. OR OWNER TO SHIM LEVEL BASE FOR ROOF CURB 60/24 OPENING IN SIDE OF DUCT GENERAL NOTES 1. All duct sizes shown are clear inside dimensions. 2. All duct gauges and supports per 2006 IMC. 3. ASEI to air balance all systems to within 0% of design airflow upon project completion. 4. Insulate supply and return duct work per Washington State Energy Code. See Plan for details. 2" liner & wrap shall insulate to R -7 minimum. 5. All ducts to be sealed per the Washington State Energy Code. COORDINATION NOTES General Contractor 1 General Contractor to cut and provide openings for all rooftop, ceiling, floor, and wall penetrations, including weatherproof sealing. ASEI to provide size and location. 2. General Contractor to provide framed openings where required for all mechanical penetrations, including headers if required. General Contractor to verify penetration locations with ASEI before framing openings. 3. General Contractor to provide all demolition, patching and painting as required for mechanical work. 4. General Contractor to spread roof and floor trusses/joists to accommodate mechanical work. 5. General Contractor to provide service access per code to all mechanical equipment. 6. General Contractor to level all factory curbs provided by ASEI, provide all cant strips and curb insulation, and seal against leaks. 7. General Contractor to provide structure for mounting and hanging members of mechanical equipment. 8. Fire damper access doors on duct work to be installed by ASEI. Access to duct work through walls and ceilings by General Contractor. Electrical Contractor 1. Electrical Contractor to provide all electrical connections, disconnects, and motor starters for mechanical equipment. 2. Electrical Contractor to verify equipment sizes, loads and locations with ASEI mechanical plan and with field conditions. 3. Electrical Contractor to provide 120v service outlet within 25 feet of each piece of mechanical equipment. 4. ASEI to install all 24 volt low voltage wiring for thermostats. 5. Electrical Contractor to install all line voltage wiring and conduit. COMPLETION As -Built Record Drawings 1. Provide record drawings with minimum information specified in WSEC 1416.1 to Owner within 90 days of system acceptance. O&M Manuals 1. Provide Operating and Maintenance Manuals with minimum information specified in WSEC 1416.2 to Owner. Systems Balancing 1. Provide a written balancing report documenting testing and balancing of air and hydronic systems as specified in WSEC 1416.3 to Owner. Systems Commissioning 1. All HVAC control systems shall be tested in accordance with WSEC 1416.4.1 and 1416.4.2. 2. For all HVAC units, verify that thermostat activates heating mode, cooling mode, for all available stages, and verify that fan is set to run during all occupied hours. Verify initial programming of thermostat. Verify unit operation per ASEI Start and Test Report. 3. For all HVAC units`<`WithF *Ironic heating ot cooling, verify that thermostat activates control valve. Verify that central plant controls maintain loop water within specified set points. 4. For all HVAC units with economizers, verify that system controls activate economizer dampers when outdoor setpoint makes free cooling available, and that dampers modulate in conjunction with mechanical cooling staging per WSEC 1413. 5. A Preliminary Commissioning Report shall be prepared, with minimum information specified in WSEC 1416.4.2.2.1. 6. A Final Commissioning Report per WSEC 1416.4.2.2.2 shall be prepared and filed with the Owner. SCOPE OF WORK 1. Furnish and Install 25 Ton Gas /Electric Rooftop Unit. 2. Remove and dispose of the existing equipment. 3. Perform system startup & test. SCALE: N.T.S. VICI \ITY fvAP S 180th St RECEIVED CITY OF TUKWIIA FEB U5 Z008 PERMIT CENTER WIRES 12/27 /Oa REVISIONS