Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M08-101 - WESTFIELD SOUTHCENTER MALL - AUNTIE ANNE'S PRETZELS
AUNTIE ANNE'S PRETZELS 546 SOUTHCENTER MALL M08.101 Parcel No.: 6364200010 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: 546 SOUTHCENTER MALL TUKW Contact Person: Name: JUNIUS W HARVEY Address: 835 N CENTRAL AV, STE 132 , KENT WA Contractor: Name: ACCO ENGINEERED SYSTEMS INC Address: 6265 SAN FERNANDO RD , GLENDALE CA Contractor License No: ACCOESI971DU DESCRIPTION OF WORK: INSTALL (1) FAN POWER VAV BOX AND (2) EXHAUST FANS Value of Mechanical: $12,800.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat /Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 CitAbf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us AUNTIE ANNE'S PRETZELS 546 SOUTHCENTER MALL , TUKWILA WA WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA MECHANICAL PERMIT EOUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 0 0 0 2 0 0 0 0 * *continued on next page ** M08 -101 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 253 854 -8444 X 131 Phone: (818)244 -6571 Expiration Date: 10/13/2009 M08 -101 04/22/2008 10/19/2008 Fees Collected: $316.25 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP/ 1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 04 -22 -2008 Permit Center Authorized Signature: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or t performance of work. I am authorized to sign and obtain this mechanical permit. Signature: Date: y o Z L c_J Permit Number: M08 -101 Issue Date: 04/22/2008 Permit Expires On: 10/19/2008 Date: 1- 1 - ,# ) -a)- - e C/ Print Name: ' V C� 0/E4— This permit shall become null and void if the work is n of commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -10/06 M08 -101 Printed: 04 -22 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 546 SOUTHCENTER MALL TUKW AUNTIE ANNE'S PRETZELS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: 2: No changes shall be made to the approved plans unless approved by the design professional m responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 10: ** *FIRE DEPARTMENT CONDITIONS * ** M08 -101 ISSUED 04/10/2008 04/22/2008 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 13: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 14: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 15: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) doc: Cond -10/06 M08 -101 Printed: 04 -22 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 18: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 19: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 20: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 21: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M08 -101 Printed: 04 -22 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: 1-0/( Date: 1,4 4/t4l 1& 6/ 1 /e),/ - doc: Cond-10/06 M08 -101 070 -,(r ordinances governing or local laws regulating Printed: 04 -22 -2008 Name: Junius W Harvey CITY OF TUKWIL• Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us SITE LOCATION Site Address: teSouthcenter mall Blvd Tenant Name: AUNTIE ANNE'S #2 Property Owners Name: WESTFIELD Mailing Address: 633 Southcenter Blvd Mailing Address: 835 north central ave suite 132 E -Mail Address: jharvey @accoes.com Company Name: ACCO ENGINEERED SYSTEMS Mailing Address: 835 north central ave Contact Person: E -Mail Address: Contractor Registration Number: Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** AC('ES1971DU suite 132 Contact Person: E -Mail Address: Company Name: ACCO ENGINEERED SYSTEMS Mailing Address: 835 NORTH CENTRAL AVE Contact Person: Chris English E -Mail Address: cenglish @accoes.com Q:Wpplications\Forms- Applications On Line'3 -2006 - Permit Application.doc Revised: 9 -2006 bh Building PermTNo. Mechanical Permit No. Plumbing /Gas Permit No. Public Works Permit No. Project No. M -4D poe (For office use only) King Co Assessor's Tax No.: 6364200010 Tukwila City Suite Number: A-1-20 — Floor: New Tenant: ❑ Yes ❑ .. No Expiration Date: 10/8/08 WA State WA. State Fax Number: 253 -854 -8220 State 98188 Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Day Telephone: 253 - 854 -8444 x131 Kent WA. 98032 City State Zip Fax Number:253- 854 -8220 GENERAL CONTRACTOR : INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Kent City Day Telephone: Fax Number: 98032 Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: City Day Telephone: Fax Number: Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record KENT WA. City State Day Telephone: 253- 854 -8444 98032 Zip Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System 2 Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment 1 fan powered VAV Air Handling Unit <10,000 CFM Incinerator— Comm/Ind MECHANICAL PERMIT INATION - 206 - 431 -3670 • MECHANICAL CONTRACTOR INFORMATION Company Name: ACCO ENGINEERED SYSTEMS Mailing Address: R35 NORTH C:FNTRAI AVF SI IITF 132 Contact Person: Austin Hanks E - Mail Address: ahankRearrnPC rnm Contractor Registration Number: cenglishcarcnes crm Valuation of Mechanical work (contractor's bid price): $ 12,800 Scope of Work (please provide detailed information): installing one fan power VAV hnx and two exhaust fans Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement .... ❑ Fuel Type: Electric ❑ Gas....❑ Other: Indicate type of mechanical work being installed and the quantity below: Q:\Applications\Fonns- Applications On Line'3 -2006 - Permit Application.doc Revised: 9 -2006 bh KFNT City Day Telephone: 253 - 854 -8444 x127 Fax Number: 253 R54 - R22(1 Expiration Date: WA 98032 State Zip 2c3 -85 -8 Page 4 of 6 • PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Print Nam Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING ER OR AU THIZED A ENT: Signature: Date: Mailing Address: 6 s /7 /? 2 Date Application Accepted: Date Application Expires: Staff Initials: Q:\ApplicationsWorms- Applications On Line'3.2006 - Permit Application.doc Revised: 9 -2006 bh City Day Telephon /, � state z, Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 6364200010 Permit Number: M08 -101 Address: 546 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 04/10/2008 Applicant: AUNTIE ANNE'S PRETZELS Issue Date: Receipt No.: R08 -01263 Payment Amount: $253.00 Initials: WER Payment Date: 04/22/2008 10:23 AM User ID: 1655 Balance: $0.00 Payee: ACCO ENGINEERED SYSTEMS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 006587 253.00 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES RECEIPT Account Code Current Pmts 000.322.102.00.0 253.00 Total: $253.00 1474 04/22 9710 TOTAL 253.00 doc: Receiot -06 Printed: 04 -22 -2008 Dnr.: REC;SETS -OR RECEIPT NO: R08 -01126 Initials: JEM Payment Date: 04/10/2008 User ID: 1165 Total Payment: 121.25 Payee: ACCO ENGINEERED SYSTEMS SET ID: S000000998 SET NAME: Trap set/Initialized Activities SET TRANSACTIONS: Set Member Amount City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //vww.ci.tukwila.wa.us EL08 -392 58.00 M08 =101' 63.25 TOTAL: 121.25 SET RECEIPT • TRANSACTION LIST: Type Method Description Amount Payment Check 006578 121.25 TOTAL: 121.25 ACCOUNT ITEM LIST: Description ELECTRICAL PERMIT - NONR PLAN CHECK - NONRES Account Code Current Pmts 000.322.101.00.0 58.00 000/345.830 63.25 TOTAL: 121.25 1033 04/10 '711 TOTAL 121.25 Project twit A_A Ni Type of Inspection: - F71 JQ 4 Address: 524 (e:;. ydlA -c1 Date Called :' Special Instructions: Date Wanted: a.m. Requester: Phone No INSPECTION RECORD. Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 112" 6300 Southcenter Blvd., #100, Tukwita, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: ?� / / , ❑ $60.0 EINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: AAA 4 pwn2 S Type of Inspection: & rialtz g1 4- abU! h Address: S 44-G, /11 4LL- Date Called: Special Instructions: Date Wanted: i lti IA p m. Requester: Phone No: 'Z -3' is - 1 2 '7 .Approved per applicable codes. INSPECTION RECORD Retain a copy with permit ,— tot PERMIT NO. ti INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Corrections required prior to approval. • COMMENTS: VAV - I ReA-uoi AJdve ss {pass S -ides tat4 oc' 15 Inspector �B. (Date: 1 i -t I OQr ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Proje . / �� /9/U Type n t� rmor Address , / / Date Called. 'Special Instructions: Date Went / / l N.tSi. Requester: Phone s2 / -7z‘7 INSPECTION RECORD Retain a copy with permit INSPECtION NO. PERMIT NO. ••It $60.00 INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: %)/4 1C2 / Inspector: Date: 6/ ild r Receipt No.: Date: _R} r.. !•:ice -. - L.. 4.ti• -.- �* . '�'.� _ �!+ �c!7'� _ COMMENTS: k s- i1 e . S Type of If e P , ' c-Y,, � c --C ;v ikl Address: l ` L Suite #: C . y1 L. Contact Pers n: Pre -Fire: N Special Instructions: Phone No.: 1-e_ ,.__ Cam... 4 L 0 -- 1. -, 1 CD SPi,tAtc 1 Project: f u , k i3 (Q k s- i1 e . S Type of If e P , ' c-Y,, � c --C ;v ikl Address: l ` L Suite #: C . y1 L. Contact Pers n: Pre -Fire: N Special Instructions: Phone No.: Needs Shift Inspection: Y Sprinklers: �r Fire Alarm: k , Hood & Duct: N Monitor: (' - ,,.,r&} 1 Pctt.) Pre -Fire: N Permits: 0 Occupancy Type: in INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit .Ma`s - io 3 - / 75 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 proved per applicable codes. Word /Inspection Record Form.Doc 1/13/06 Ti Corrections required prior to approval. Inspector: Date: 7)//e3/4- Hrs.: L4- Z $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 ACTIVITY NUMBER: M08 -101 DATE: 04 -10 -08 PROJECT NAME: AUNTIE ANNE'S SITE ADDRESS: 546 SOUTHCENTER MALL DEPARTMENTS: Bui irr g Di ision Public Works Complete Documents/routing slip.doc 2 -28 -02 Comments: Please Route aPERMITCOORD COPY • PLAN REVIEW /ROUTING SLIP X Original Plan Submittal Response to Correction Letter # n TUES/THURS ROUTING: REVIEWER'S INITIALS: 61d v 4 Fire Pr evention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Structural Review Required APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: Response to Incomplete Letter # Revision # After Permit Issued ❑ Permit Coordinator n DUE DATE: 04-15-08 Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: No further Review Required DATE: DATE: Planning Division Not Applicable n DUE DATE: 05-13 -08 Not Approved (attach comments) Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License ACCOESI971 DU Licensee Name ACCO ENGINEERED SYSTEMS INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601003669 Ind. Ins. Account Id SECRETARY Business Type CORPORATION Address 1 6265 SAN FERNANDO RD Address 2 City GLENDALE County OUT OF STATE State CA Zip 91201 Phone 8182446571 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 3/31/2003 Expiration Date 10/13/2009 Suspend Date Separation Date Parent Company Previous License AIRCOCI 131 KQ Next License Associated License Business Owner Information Name Role Effective Date Expiration Date AVESANO, JOHN P PRESIDENT 03/31/2003 KESSLER, ROBERTA R SECRETARY 03/31/2003 BROWN, ROBERT A TREASURER 03/31/2003 KRASSENSKY, RONALD VICE PRESIDENT 01/22/2004 HAMMOND, ROBERT T VICE PRESIDENT 01/22/2004 MARRS, JEFFREY R VICE PRESIDENT 01/22/2004 Look Up a Contractor, Election or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. • Page 1 of 4 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= ACCOESI971 DU 04/22/2008 HVAC LEGEND DUCT SYMBOL LEGEND DUCT SYMBOL LEGEND PIPING SYMBOL LEGEND ABBREVIATIONS SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION ABBRV. DESCRIPTION ABBRV. DESCRIPTION ABBRV. DESCRIPTION (N) `� (E) NEW(N) & EXISTING(E) RECTANGULAR SUPPLY AIR DUCT RISER f e MANUAL VOLUME DAMPER AUTOMATIC AIR VENT ABV. A/C A.D. ADJ. A.F.F. A.P. APPROX. & © BD. B.D.D. B BF.V. B.O.D. B.O.P. B.V. BLDG BTM. CLG CFM CH.V. CHWR CHWS CMU CONC. CONTR. CWR CWS COND. DMP'R. DET. D/L DN DWG (E) EA. E.A. EAG EAR EL. ELB ELECT. ELEV. EQUIP. EXH EXP EXT. (F) F.C. FD FIN. FLEX FLR FSD FT. ABOVE AIR CONDITIONING ACCESS DOOR ADJACENT ABOVE FINISHED FLOOR ACCESS PANEL APPROXIMATE AND AT BOARD BACKDRAFT DAMPER BOTTOM FLAT BUTTERFLY VALVE BOTTOM OF DUCT BOTTOM OF PIPE BALL VALVE BUILDING BOTTOM CEILING CUBIC FEET PER MINUTE CHECK VALVE CHILLED WATER RETURN CHILLED WATER SUPPLY CONCRETE MASONRY UNIT CONCRETE CONTRACTOR CONDENSER WATER RETURN CONDENSER WATER SUPPLY CONDENSATE DAMPER DETAIL DOOR LOUVER DOWN DRAWING EXISTING EACH EXHAUST AIR EXHAUST AIR GRILLE EXHAUST AIR REGISTER ELEVATION ELBOW ELECTRICAL ELEVATOR EQUIPMENT EXHAUST EXPANSION EXTERIOR FUTURE FLEXIBLE CONNECTION FIRE DAMPER FINISH FLEXIBLE FLOOR FIRE SMOKE DAMPER FOOT (FEET) GA. GALV. G.I. G.V. GEN. GPH GPM GYP HGT. HI. H.O.A. HR. HWR HWS I.D. IN. 1 INSUL INT. (L) L LBS. L.D, M.A. MACH. MAN. MAX. M.D. MECH. MFR. MIN. MISC. MTD MTL. MTR. M.U.A. M.V.D. (N) N/A NC N.I.C. NO NO. N.R. NTS O.C. O.D. OPER, OPP. OPN'G. O.S.A. P.O.C. PLUMB'G. P.S.I. GAUGE GALVANIZED GALVANIZED IRON GATE VALVE GENERAL GALLONS PER HOUR GALLONS PER MINUTE GYPSUM HEIGHT HIGH HAND —OFF —AUTO HOUR HOT WATER RETURN HOT WATER SUPPLY INSIDE DIMENSION INCH INSULATION INTERIOR LINED LONG POUNDS LINEAR DIFFUSER MIXED AIR MACHINE MANUAL MAXIMUM MOTORIZED DAMPER MECHANICAL MANUFACTURER MINIMUM MISCELLANEOUS MOUNTED METAL MOTOR MAKE UP AIR MANUAL VOLUME DAMPER NEW NOT APPLICABLE NORMALLY CLOSED NOT IN CONTRACT NORMALLY OPEN NUMBER NOT RATED NOT TO SCALE ON CENTER OUTSIDE DIMENSION OPERATING OPPOSITE OPENING OUTSIDE AIR POINT OF CONNECTION PLUMBING POUNDS PER SQUARE INCH (R) R R.A. RAG RAR RND. REQD REV. RF. RM. S.A. SAG SAR S.D. SHT. S.I. S SQQ. . S.S. STD. STRUCT. SUSP SW SWG SWR TAG T.F. T.O.D. T.O.P. TRANS. T'STAT TYP. UBC U.C. U.G. UMC U.N.O. U.T.R. V. VAV VLV. VSD VOL. WMS WT. RELOCATE RADIUS RETURN AIR RETURN AIR GRILLE RETURN AIR REGISTER ROUND REQUIRED REVISION ROOF ROOM SUPPLY AIR SUPPLY AIR GRILLE SUPPLY AIR REGISTER SMOKE DETECTOR SHEET SOUND INSULATION SQU METAL SQUARE STAINLESS STEEL STANDARD STRUCTURAL SUSPENDED SWITCH SIDE WALL GRILLE SIDE WALL REGISTER TRANSFER AIR GRILLE TOP FLAT TOP OF DUCT TOP OF PIPE TRANSFER THERMOSTAT TYPICAL UNIFORM BUILDING CODE UNDER CUT UNDER GROUND UNIFORM MECHANICAL CODE UNLESS NOTED OTHERWISE UP THROUGH ROOF VENT VARIABLE AIR VOLUME VALVE VARIABLE SPEED DRIVE VOLUME WIRE MESH SCREEN WEIGHT (N) I (E) NEW(N) EXISTING(E) RECTANGULAR RETURN AIR DUCT RISER & 0 MECH. CONTR. TO PROVIDE EQUIPMENT & INSTALLATION (U.N.O.) BALL VALVE " (N) ( E ) NEW(N) & EXISTING(E) RECTANGULAR EXHAUST AIR DUCT RISER [ } �• MOTORIZED DAMPER (ELECTRIC) BUTTERFLY VALVE —1 (N) (E) NEW(N) & EXISTING(E) ROUND MR DUCT RISER [ p ] -- . � . LJJ11 MOTORIZED DAMPER (PNEUMATIC) E BLIND FLANGE 5.--r NEW SINGLE & DOUBLE UNE RECTANGULAR OR ROUND DUCT S POINT OF CONNECTION —N.„1-- CHECK VALVE ° a a E XISTING SINGLE & DO UBLE LINE RECTANGULAR OR ROUND DUCT • ! j� �' RETURN AIR GRILLE (NEW & EXISTING - 24x24 PANEL) a� CIRCUIT SETTER ,r "f EXISTING DUCTWORK TO BE DEMOLISHED MI El RETURN AIR REGISTER (NEW Sc EXISTING -SURF. MTD.) -- t DRAIN (ROOF, FLOOR) y �} SINGLE & DOUBLE UNE DUCTWORK WITH TRANSITIONAL FITTING RETURN AIR GRILLE - 24x12 (NEW & EXISTING - T -BAR CEIL'G.) 4- END CAP 111 � SQUARE E ROUND SQUARE TO ROUND TRANSITIONAL FITTING REVISION CLOUD 9 FLOW SWITCH SQUARE OVAL SQUARE TO OVAL TRANSITIONAL FITTING X REVISION DELTA GATE VALVE � (3.61:1 2 ���.11L 90' RADIUS ELBOW J 9O' SQUARE ELBOW WITH TURNING VANES ® M r. Q;C� ; 1C� ` ROUND CEILING DIFFUSER (NEW & EXISTING) FLEXIBLE CONNECTION 0 ROUND DUCT TURNING DOWN O7 RECT. DUCT TURNING DOWN Q I 4TTON SECTION NUMBER CALL OUT SYMBOL SHEET NUMBER FLOW CONTROL AIR TIGHT (DOOR, SHAFT, ETC.) BY OTHERS. 8 SUPPLY AIR GRILLE (NEW & EXISTING - 24x24 PANEL) T PETE'S PLUG >f � BACK DRAFT DAMPER � , SUPPLY AIR REGISTER (NEW & EXISTING -SURF. MTD.) PIPE (NEW) S S ® CEILING OR DUCT ACCESS PANEL OR DOOR Q SMOKE DETECTOR (AREA TYPE) PIPE (EXISTING) S CENTER UNE 1= SMOKE DETECTOR (DUCT TYPE) Q • • PRESSURE GAUGE WITH COCK I —DETAIL NUMR SHEET NUMBER UB BE T SYMBOL SIDE WALL REGISTER, GRILLE REDUCER EXHAUST AIR GRILLE (NEW & - 24x24 PANEL) o ® WALL SWITCH WATER SYSTEM TYPE RISER CALL, LL OUT SYMBOL NUMBER • Li :� NW - r -r i EXHAUST AIR REGISTER (NEW & EXISTING -- SURF. MTD.) # THERMOSTAT WITH ZONE NUMBER SCHRAEDER VALVE a ELECT. CONN. LOCATION TO EQUIP. (APPROX.) BY ELECT. CONTR. w1 0 TRANSFER AIR GRILLE (NEW & EXISTING - SURF. MTD.) STRAINER { I EQUIPMENT TAG LABEL COOLING ONLY VAV BOX WITH SQUARE TO ROUND OUTLET STRAINER W/DRAIN VALVE AND HOSE ADAPTER 1 EQUIP --# 1 1%1 FIRE DAMPER (SINGLE UNE AND DOUBLE UNE) REHEAT VAV BOX WITH SQUARE TO ROUND OUTLET TEMPERATURE SENSOR WELL M t_l • FIRE /SMOKE DAMPER (SINGLE UNE AND DOUBLE LINE) COOLING ONLY VAV BOX WITH RECTANGULAR LINED S.M. PLENUM THERMOMETER ® kfftl. p FIRE DAMPER LABEL REHEAT VAV BOX WITH RECTANGULAR LINED S.M. PLENUM X TRIPLE DUTY VALVE Vir 4M4 FIRE /SMOKE DAMPER LABEL 12"4 -4W 12x12 -4W 250 250 CFM CFM DIFFUSER NECK SIZE -AIR PATTERN -AIR VOLUME UNION �--- -4 �- l \ 1 1 1 111\\ FLEXIBLE DUCT T VENT 1 1 LINEAR DIFFUSER (SUPPLY OR RETURN) ® VICTAUUC COUPLING (3) ' ' WATER FLOW DIRECTION DRAWING INDEX SHEET NO. SHEET TITLE REV DATE MO.O COVER SHEET, DRAWING INDEX, LEGENDS /IX 03/21/08 M2.1 SCHEDULES, HVAC PLAN /0\ 03/21/08 AUNTIE ANNE'S WEST 5V6 -1120 '' OUTHCENTER MALL TUKWILA WA 98188 engineered systems 835 N. CENTRAL AVE., #132 KENT, WA 98032 Office (253) 854 -8444 Fax (253) 854 -8444 3EPARATE PERMIT REQUIRED FOR: 0 Mechanical [ .Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION REVIEWED FOR-- O CIE CODE COMPLIANCE APPROVED APR1 N Of Tukwila BUILDING Wisipm .. SCOPE OF WORK t INSTALL A VAV BOX WITH ASSOCIATED DUCTWORK. 2. EXHAUST AIR IN BATHROOM AND SCULLERY. FILE C Permit No Par review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordnance. Receipt of approved Field Copy and conditions is acknowledged: By Date: , � U ' ` V City of Tukwila Bt ?iLDING DIVISION r---- REVISIONS I No changes shall be PMacle to tha ScOre of work without prior approval of Tukwila Building Division NOTE: Revisions will require a new plan submittal - Tnd may include additional plan re.►i°W^a fees A RECEIVED CITY OF TUKWILA APR 10 2008 PERMIT CENTER engineered stems 835 N. CENTRAL AVENUE, SUITE 132 KENT, WASHINGTON 98032 (253) 854 -8444 THE DESIGN IS EXCLUSIVELY OWNED BY ACCO ENGINEERED SYSTEMS, AND IS NOT INTENDED FOR PUBLICATION. EXHIBITION HEREOF IS SOLELY FOR THE PURPOSE OF EFFECT /NGA SALE OR TRANSFER OF THE DELINEATED MECHANICAL AND OR CONTROLS SYSTEMS. A / " \ 03/21/08 No. Date Revisions PERMIT DRAWINGS Description GAH By Project AUNTIE ANNE'S SOUTHCENTER MALL s THCENTER MALL TUKWILA, WA Title Scale File Name COVERSHEET DRAWING INDEX LEGEND GAH CE Designed By Checked By GAH SO Drawn By Project Manager Job Number NO_SCALE FO M0.0 1 Of 2 Sheets DUCT INSULATION SCHEDULE DUCT TYPE R- VALUE INSULATION CONCEALED SUPPLY INSIDE THE CONDITIONED ENVELOPE 3.3 1.5 - 3.0 it/CF, 1" FOIL FACED CONCEALED SUPPLY INSIDE THE CONDITIONED ENVELOPE 7,0 1.5 - 3.0 # /CF, 2" FOIL FACED EXPOSED SUPPLY WITHIN CONDITIONED SPACE 0 NONE SUPPLY DUCT EXPOSED TO WEATHER 7 1.5 -3.0 # /CF, 2" DUCT LINER RETURN DUCT INSIDE THE CONDITIONED ENVELOPE 0 NONE RETURN DUCT EXPOSED TO WEATHER 7 1.5 -3.0 # /CF, 2" DUCT LINER OSA DUCT UPSTREAM OF THE CONTROL DAMPER(SEE NOTE 3) 11 3-1/2" FOIL FACED WRAP MIXED AIR PLENUMS 0 NONE EXHAUST DUCT 0 NONE RETURN AIR SHAFT OUTSIDE OF CONDITIONED SPACE 7 1.5 # /CF, 2" DUCT LINER NOTES: 1. THIS SCHEDULE DERIVED FROM 2006 WASHINGTON STATE ENERGY CODE SECTION 1414.2 AND TABLE 14 -5. 2. SEE FLOOR PLANS FOR LINED DUCT. 3. CONTROL DAMPER MUST MEET 2006 WASHINGTON STATE ENERGY CODE 1412.4.1. VICINITY MAP SYMBOL LOCATION MANUFACTURER & MODEL No. SERVING r S.P. RPM VOLTAGE WEIGHT (Ibs) --, EF--1 BATHROOM MACEYS f - BATHROOM 177 r 740 1.8 120/1/60 23.0 (Ibs) REMARKS EF -2 SCULLERY BROAN L300 SCULLERY 287 0.5 905 2.6 120/1/60 23.1 (I6s) REMARKS 'm r ----------- ----- • PPR r' SEARS , B F n L r APR ' \ / � • Of Tv4 _ILI lviSQ ASSESSOR'S PARCEL NUMBER: 6364200010 ASSESSORS LEGAL DESCRIPTION : OLIVE GARDEN RESTAURANT -BSP 0 EXHAUST FAN SYMBOL LOCATION MANUFACTURER & MODEL No. SERVING CFM S.P. RPM AMPS VOLTAGE WEIGHT (Ibs) REMARKS EF--1 BATHROOM B 200DN BATHROOM 177 0.5 740 1.8 120/1/60 23.0 (Ibs) REMARKS EF -2 SCULLERY BROAN L300 SCULLERY 287 0.5 905 2.6 120/1/60 23.1 (I6s) REMARKS VARIABLE VOLUME BOX SYMBOL LOCATION MANUFACTiJF -R & MODEL No. COOLING ONLY WEIGHT (Ibs) REMARKS CFM S.P. VAV -1 BACK ROOM NAILOR 3001 -12 1200 0.5 85 (Ibs) PINCH BOX ONLY. AIR DISTRIBUTION SCHEDULE TAG# DESCRIPTION MFG. & MDL # BVP NECK SIZE SURFACE FINISH REMARKS SD -1 MODULAR CORE 10 NECK TITUS MCD 1 SEE DWG N/A WHITE DROP IN STD. T -BAR SD-2 MODULAR CORE 12" NECK TITUS MCD 1 SEE DWG N/A WHITE DROP IN STD. T -BAR SD- 350 0 450 0 V V HVAC PLAN SCALE: 1/2" =1' -0 CONTROLLED BY LIGHT SWITCH SUPPLY AIR P.0.C. 0 X WIRED BY EC L 11'-2" V CONTROLLED BY LIGHT SW .6* PER 2006 IMC SECTION 606 Install smoke detector to shut down air distribution by VAV's when the total combined C F M of all VAV's (to include other tenants) sharing the same plenum space exceeds 2000 CFM. (See IMC 606.2.2 for approved method of detection EXHAUST AIR P.C.C. 'NE TCH DUCTWORK NOTES 1. ALL PRODUCTS SHALL COMPLY WITH SMACNA DUCT CONSTRUCTION STANDARDS, FIRST EDITION. 2. SEAL ALL DUCTWORK AS NECESSARY. 3. MAXIMUM FLEX LENGTH IS 7' --0 ". SUPPORT WITHOUT SAGS OR KINKS. 4. ALL DUCTWORK SIZES SHOWN ARE SHEET METAL SIZES. SUBTRACT APPROPRIATE DIMENSION FOR LINING TO OBTAIN CLEAR DIMENSIONS. 5. PROVIDE DIFFUSER FRAME COMPATIBLE WITH CEILING TYPE. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR CEILING. 6. ALL SUPPLY AIR DUCTWORK TO BE 2" W.C. PRESSURE CLASS, EXCEPT DUCTWORK DOWNSTREAM OF VAV BOXES AND HEAT PUMPS MAY BE 1" W.C. PRESSURE CLASS 7. ALL EXHAUST DUCTS TO BE 1" W.C. PRESSURE CLASS. FLOOR RUNOUTS MAY BE 1" W.C. PRESSURE CLASS. 8. ALL RETURN DUCT SHALL BE 1" W.C. PRESSURE CLASS. 9. INSULATE ALL DUCTWOK PER TABLE 14-5 OF THE 2006 WASHINGTON STATE ENERGY CODE. GENERAL NOTES 1. ALL WORK TO CONFORM TO 2006 WASHINGTON STATE MECHANICAL CODE AND AUTHORITIES HAVING JURISDICTION. 2. ALL EQUIPMENT SHALL BE REGULARLY CATALOGED ITEMS OF THE MANUFACTURER AND SHALL BE SUPPLIED AS A COMPLETE UNIT IN ACCORDANCE WITH THE MANUFACTURER'S STANDARD SPECIFICATIONS AND ANY OPTIONAL ITEMS REQUIRED FOR PROPER INSTALLATION UNLESS OTHERWISE NOTED. 3. ADJUSTING AND BALANCING: ADJUST EACH PART OF SYSTEM TO INSURE PROPER FUNCTIONING OF ALL CONTROLS, SPECIFIED AIR DISTRIBUTION, AND ENTIRE SYSTEM LEFT IN OPERATING CONDITION. 4. ALL CUTTING, PATCHING AND PAINTING OF BUILDING ELEMENTS AND FINISHED SURFACES IS TO BE DONE BY THE GENERAL CONTRACTOR. 5. ACCESS DOORS AND /OR ACCESS PANELS THROUGH FIRE RATED WALLS, SHAFTS, CEILINGS, ETC., MUST EQUAL THE MATERIAL PENETRATED. 6. ALL APPLIANCES DESIGNED TO BE FIXED IN POSITION SHALL BE SECURELY FASTENED IN PLACE. 7. ALL EQUIPMENT SHALL BE LABELED PER PLANS. 8. PROVIDE NEC CODE MINIMUM WORKING CLEARANCE IN FRONT OF ANY ELECTRICAL PANEL. OFFSET EQUIPMENT AS REQUIRED. 9. T'STATS SHALL BE 7 DAY PROGRAMMABLE W /5' DEADBAND. 10. MECHANICAL SYSTEM SHALL BE COMMISSIONED IN COMPLIANCE WITH SECTION 1416 OF THE 2006 WASHINGTON STATE ENERGY CODE. SITE MAP CITY Of TUKWILA APR 10 2008 PERMIT CENTER engineered systems 835 N. CENTRAL AVENUE, SUITE 132 KENT, WASHINGTON 98032 (253) 854 -8444 THE DESIGN IS EXCLUSIVELY OWNED BY ACCO ENGINEERED SYSTEMS, AND IS NOT INTENDED FOR PUBLICATION. EXHIBITION HEREOF IS SOLELY FOR THE PURPOSE OF EFFECTING A SALE OR TRANSFER OF THE DELINEATED MECHANICAL AND OR CONTROLS SYSTEMS. A / " \ 03/21/08 No. Date Revisions PERMIT DRAWINGS Description GAH By Project AUNTIE ANNE'S SOUTHCENTER MALL OUTHCENTER MALL TUKWILA, WA Title HVAC FLOOR PLAN SCHEDULES GAH CE Designed By Checked By GAH so Drawn By Job Number 1/2 Scale File Name r FO Project Manager M2.1 2 Of 2 Sheets