Permit M08-170 - DIGITAL FOREST
DIGITAL FOREST 12101 TUKWILA INTERNATIONAL BL M08 -170 Parcel No.: 0923049031 Address: Suite No: Contact Person: Name: JEROD SHEEKS Address: 7717 DETROIT AV SW , SEATTLE WA Value of Mechanical: 107,305.00 Type of Fire Protection: Furnace: <100K BTU > 100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: I MC -10/06 CitAff Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 12101 TUKWILA INTERNATIONAL BL TUKW MECHANICAL PERMIT Tenant: Name: DIGITAL FOREST Address: 12101 TUKWILA INTERNATIONAL BL , TUKVVILA WA Owner: Name: INTERNATIONAL GATEWAY WEST Address: 12201 TUKWILA INTERNATIONAL BLVD , SEATTLE WA Contractor: Name: MACDONALD /MILLER FAC SOL INC Address: PO BOX 47983 , SEATTLE, WA Contractor License No: MACDOFS980RU DESCRIPTION OF WORK: ADD (1) AC UNIT TO SERVE DATA CENTER AND MISC DUCTWORK EOUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 0 1 0 0 0 0 0 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 768 -3806 Phone: 206 - 768 -4180 Expiration Date: 12/31/2008 M08 -170 07/07/2008 01/03/2009 Fees Collected: $1,276.25 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment M08 -170 Printed: 07 -07 -2008 Permit Center Authorized Signature: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: M08 -170 Issue Date: 07/07/2008 Permit Expires On: 01/03/2009 Date: 0q I hereby certify that I have read and e ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied 't whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: C(, Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -10/06 Date: Cr) (0) (Og/ M08 -170 Printed: 07 -07 -2008 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 0923049031 Permit Number: M08-170 Address: 12101 TUKWILA INTERNATIONAL BL TUKW Status: ISSUED Suite No: Applied Date: 06/20/2008 Tenant: DIGITAL FOREST Issue Date: 07/07/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: The special inspections for steel elements of buildings and structures shall be required. All welding shall be done by a Washington Association of Building Official Certified welder. 6: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 7: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 8: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: ** *FIRE DEPARTMENT CONDMONS * ** 14: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: doc: Cond -10/06 M08 -170 Printed: 07 -07 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 15: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 16: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 17: Local U.L. central station supervision is required. (City Ordinance #2051) 18: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 19: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 20: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 21: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 22: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 23: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 24: These plans were reviewed by Inspector 0700. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * * continued on next page ** M08 -170 Printed: 07 -07 -2008 doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. 07707 � y/ Signature: _ Date: Print Name: TI ��l / { � e >< M08 -170 Printed: 07 -07 -2008 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 httt:llwww. ci. tukwila. wa. us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: D 9 2 O ! 3 0 ° ) Site Address: ) Z I 0 1 Tikkig'la 1b C N I SS. l V 2 Suite NumberN / Q Floor: CGo F Tenant Name: 1 9 i 1 CQY2s+ New Tenant: ❑ Yes A No Property Owners Name:' i g 1�1 1 � - C-6 r^ e 1 TN C �, r Mailing Address: Iv 01 1 TA As L-tJ0 #N1U Se { l..0 �'1S(1 CONTACT PERSON Name: & S In.JULK.5 Mailing Address: -1 1 1 1 e_. 'r"C) A t e E -Mail Address: GENERAL CONTRACTOR INFORMATION — (Contractor Infokination for Mechanical (pg 4) for PIumbing and G' Company Name: Mailing Address: Company Name: Mailing Address: Contact Person: E -Mail Address: Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: ARCHITECT OF RECORD -All plans must be wet ENGINEER OF RECORD,; W \pplica ions \Forms- Appliea0ons On Line '3 -2006 - Permit Application.doc Reviaed' 4-2006 bh lie wet stamped ping (pg Contact Person: E -Mail Address: w TUKWILA w No. Building Pe Mechanical Per Piumiiin Public only) Day Telephone:(2 00 "7(,% 3,10 (o SG. SQt LA.YA q lOta City State Zip City State Zip Fax Number: City Day Telephone: Fax Number: Lion Date: Stat stamped by Architect of Recor City Day Telephone: Fax Number: ineer.of Recorc to State Zip Zip I plans mus City Day Telephone: x Number: Z ip Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM i Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to HeatiRefrig /Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — Comm/Ind Other Mechanical Equipment MECHANICAL PERMIT INFORMATION - 206 -031 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: A Y‘A `` Mailing Address: "1"1 1 " \ - CD e 1 Contact Person: �r tzV d E -Mail Address: Contractor Registration Number: IA Ort7 0 es 9 %O J, ) Valuation of Project (contractor's bid price): $ / 0 7 � j0 S Scope of Work (please provide detailed information): AAA \ 'fr6 S-A r v 2 C..lL.r oti�n . Yv \ S ( c\.v Ck w n New .... ❑ Replacement .... ❑ I Use: Residential: Commercial: New Replacement ... Sw Fuel Type: Electric Gas ....D Other: Indicate type of mechanical work being installed and the quantity below: City " �, State Zip 6 -a-) Day Telephone: -UL) 7 (, Fax Number: Expiration Date: —o Q: Applieations\Fomts •Applications On 6ine13.2006 - Permit Application.duc Revised: 4 -2006 bh Page 4 of 6 I Date Application Accepted: A - ,� /`CD [ Date Application Expires: f Z � �� rf � ` ( Stafflnitials: / i I PERMIT APPLICATION NOTES — Applicable to all permits in this Value of Construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Buildine and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing code (current edition). I HEREBY CERTIFY THAT! HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY 13Y THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILD C OWN • • THORIZED AG Date: (e — Q — 6 7 y /� " Day Telephon X a�oZ .) - 7 1 - 2 N Mailing Address: -- 1 - 1 1 �'\ 2 "tr-o'11 It-t S � C. a t W44 91 27 o S, Signature. Print Name: - 910k2LA � ei t� Q :t■ppiieationsTorms- AppGcationa Ou L4ne3-2606 - Permit App6cation.d0c Revised: 4- -2006 bh City state Zip Page 6 of 6 n - -. nnn•mmL nn RECEIPT NO: R08 -02203 Initials: JEM User ID: 1165 SET TRANSACTIONS: Set Member Amount ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http.• / /www.ci.tukwila.wa.us SET RECEIPT Payee: MACDONALD- MILLER FACILITY SOLUTIONS, INC. Payment Date: 06/20/2008 Total Payment: 3,138.00 SET ID: 0620 SET NAME: MACDONALD MILLER M08 -169 251.50 M015770 2,886.50 TOTAL: 3,138.00 TRANSACTION LIST: Type Method Description Amount Payment Check 1768 3,138.00 TOTAL: 3,138.00 Account Code Current Pmts 000.322.102.00.0 1,265.00 000/345.830 1,873.00 TOTAL: 3,138.00 3869 06/20 9711 TOTAL 3138.00 Proj t: i 6 /7 4 /lS Type of Iection: f- inlet / Address: / /D/ 7 r3 Date Called: Special Instructions: Date Wanted: 7- / 4-/-/U a.m: p.m. Requester: Phone No: ?o6 -25 -y75 0 INSPECTION NO. INSPECTION RECORD Retain a copy with permit d O /YIUB -/7 0 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 V Approved per applicable codes. Corrections required prior to approval. COMMENTS: - 7 - / (' gyp/ ' /t;;07` Date: 7 'v — 'Q 0.00 REINSPECTION FE REQUIRED. Prior to inspection, fee must be aid at 6300 Southcenter B : d., Suite 100. Call to schedule reinspection. (Receipt No.: (Date: gc- Project: — �_ /..) / CI /4/ , ✓ / Type of Inspection: t" , t/d 9 Address: /a /O/ 7 QQ __.3 Date Called: Special Instructions: Date Wanted: ..7- 23-C-2 p.m. Requester: Phone No .206- 396 - 9 'V, INSPECTION RECORD Retain a copy with permit INS CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -31 Approved per applicable codes. / © -/ Corrections required prior to approval. COMMENTS: /- ,;, i / 4,'4 t� -- J/ 1 Inspecto ipt No.: Da - - -,3 -d INSPECTION FEE REQ IRED. P f or to inspection, fee m s�ft be t 6300 Southcenter Blvd., ite 10 . Call to schedule reinspection. `Date: Proj ct: , -.-.. t dj /1, lel / / = d ✓o<ri T of l�spection: c�0+ct /�4.�f2�d lu/il. Address: /� % __ / a / L _ ,(9 Date Called: Special Instructions: Date Wanted: /7- 2.3- c9 c5 p.m. Requester: Phone No: 010 a 39 42v —96 /.. INSPECTION RECORD Retain a copy with permit INSPEC NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION i 6300 Southcenter Blvd., #100, Tukwila, WA 98188 - (206)431 -3 /t2o' -/7O D Approved per applicable codes. Corrections required prior to approval. I / COMMENTS: / , IZ f p/14 1 /r, A/ 4 .1-y 49)$./9/0--/ , 7, 1 2 / frovepe Inspector -e�--tr .00 REINSPECTION FEE R Id at 6300 Southcenter Blvd Refipt No.: / 'Date: QUIRE nor to inspection, fee must be ., Suit 100. Call to schedule reinspection. 'Date: Proj Ty of Inspe tioQ: Ad - 1 O 1 6 Date Called. Special Instructions: Date Wanted 7-2-9 -Qe t . p.m. Requester: Phone No 26%- 25 4' 75OC, - INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100; Tukwila, WA 98188 (206)431- 3670+ 171 Approved per applicable codes. • • Rice -(70 Corrections required prior to approval. A COMMENTS: tos-TALL.ct Pct. FFJ c�E"rAilr t C °'t Y ., i - L) /44- Date: 7 -zS - e $ i 00 REINSPECTION FEE REQUIR D. Prior to inspection, fee must be t id at 6300 Southcenter Blvd., Suit 100. Call to schedule reinspection. 1 Receipt No.: 'Date: REVIEWED 0 COD COMPLIANCE APPROVED JUL 0 2008 City O N Alb Structural Calculations For: DIGITAL FOREST Additional HVAC Load Checks at Roof (Building "C") 12101 Tukwila International Boulevard TUKWILA, WA 98168 POGGEMEYER DESIGN GROUP, INC. NW DIVISION June 18t 2008 PDGJOB No. 8035 OV row I EXPIRES OCTOBER 24 0 1 O POGGEMEYER DESIGN GROUP CONSULTING ENGINEERS RECEIVED CITY OF TUKWILA JUN 2 0 2008 PERMIT CENTER 512 6'" ST S., STE 202 KIRKLAND, WA 98033 425/827 -5995 PHONE 425/828 -4850 FAX PDG- WA@PDG- WA .COM Kevin Teker June 18"', 2008 POGGEMEYER Facilities Manager DESIGN GROUP Digital Forest CONSULTING ENGINEERS 12101 Tukwila International Blvd. Tukwila, WA 98168 Subject: Executive Summary Building at 12101 Tukwila International Blvd. (Building "C") Analysis of Existing Structure to Support Proposed and Existing HVAC Frame Loadings at Roof Mr. Teker: As requested, the roof of the building located at 12101 Tukwila International Blvd (Bldg. C) has been structurally evaluated for the loading imposed by the existing and proposed HVAC rooftop units (as shown and dimensioned on page Si, attached). The conclusions in this letter are limited to the specific areas of the roof as indicated in the attached layout drawing in the sketch, S1. Based on our study, it is structurally acceptable to locate these (5) 7,000 lbs. HVAC units, with associated 6,400 lbs. steel frames, per the dimensions as shown on the attached drawing. refer to the attached sheet S1 of this report for details on the locations of the platform frames on top of which the units shall be placed. Also included with this letter are calculations to substantiate our conclusion. All steel used in the construction of the platform frame shall be treated to prevent corrosion — either some method of galvanization or a sealant paint may be used. Please feel free to contact me if you have any questions or comments. Sincerely, Ben Fisher 1 Project Engineer Poggemeyer Design Group, Inc. www.poggemeyer.com 512 Sixth Street South, Suite 202 Kirkland, WA 98033 512 6 ST S., STE 202 KIRKLAND, WA 98033 425/827 -5995 PHONE 425/828 -4850 FAX PDG- WA@PDG. WA.COM 1 - - ® - - - - - - - A Co 16' -5" LOCATIONS OF HVAC UNITS AND SUPPORT FRAMES DIGITAL FOREST (ROOF) 12101 TUKWILA INT'L BLVD TUKWILA, WA 98168 8 27' -0" 19' -0" Y....G'Wltbi46i' MOM i Y ilia POGGEMEYER DESIGN GROUP NORTHWEST DIVISION CONSULTING ENGINEERS 5T2 6TH STREET SOUTH, SUITE 202 KIRKLAND. WASHINGTON 98033 (425) 827 -5995 19' -6" is 0 O 0 0 0 0 0 0 DAR RENISCN ANY POORNA110N OR DATA ON IRS ORATAWO Is NOT INTENDED TO BE SUITABLE FOR REUSE RY ANY PERSON 044, CORPORATION, OP ANY OTHERS ON (01EN90N5 Of INS PROJECT OR FOR ANY USE ON ANY OTHER PRQ[CT. ANT REUSE *MINOUT WRITTEN VERIFICATION ANO ADAPTAPON BY THE ENGINEER FOIE THE SPECIFIC PURPOSE INTENOEO WTLL BE AT 114E USER'S SOLE R15N AND MYIICUT UABIUTY OR LEGAL EXPOSURE TO THE ENGINEER. Z / Y X Poggemeyer Design Group, Inc. Current Date: 6/18/2008 12:53 PM Project: HVAC Frame Addition (Simple Frame) Units system: English Job Number: 7094.1 File name: P: \Current Projects \7094 -1 Digital Forest UPS Installation \Design \Calculations Folder \SimplePlatforml.adv Com an Address: 512 Sixth Street S, Suite 202, Kirkland, WA 98033 N // \ �' - ---,N 16 N'1 / � - .�,N 17 �N , P� 14 // --- --- N' 6 IN 2 ' / N 10 /�„ j . ------. N 20 ' N 11 /' N21 / - - 7 ' - -=y / N 12 '�� 7 �' \> N , � // -. �N 18 13 // / / / / �'`�N' 19 / // --------- N / / i / / / N4 i r r i Ail 1 Poggemeyer Design Group, Inc. V Poggemeyer Design Group, Inc. Current Date: 6/18/2008 1:08 PM Project: HVAC Frame Addition (Simple Frame) Units system: English Job Number: 7094.1 File name: P: \Current Projects\7094 -1 Digital Forest UPS Installation \Design \Calculations Folder\SimplePlatform1.adv Company Address: 512 Sixth Street S, Suite 202, Kirkland, WA 98033 Y Z j X degO ut7F1D os= (,(tit M"dw — 1.597887 [Kip] q- z= 1.597887 Ki [ p] Poggemeyer Design Group, Inc. Current Date: 6/18/2008 1:11 PM Units system: English Job Number: 7094.1 File name: P:1Current Projects17094 -1 Digital Forest UPS Installation \Design \Calculations Folder\SimplePlatforml.adv Company Address: 512 Sixth Street S, Suite 202, Kirkland, WA 98033 Z � (4 c,T (ioP O OSE FWt- 3E4m 1.1 E Project: HVAC Frame Addition (Simple Frame) - 4.669956 [Kip] L 3.993929 [Kip] P V Poggemeyer Design Group, Inc. Current Date: 6/18/2008 1:11 PM Units system: English Job Number: 7094.1 File name: P: \Current Projects \7094 -1 Digital Forest UPS Installation \Design \Calculations Folder \SimplePlatforml.adv Company Address: 512 Sixth Street S, Suite 202, Kirkland, WA 98033 Z Y � / X 2 . 5 ' A.A i r'E 1,oAO Cl %fe f�N PscR�nn Vrn�� Pnfl.� ,v To (, j to G . Project: HVAC Frame Addition (Simple Frame) ,z= 2.161886 [ Kip] p] 7 1 Poggemeyer Design Group, AIII Inc. . iir Current Date: 6/18/2008 1:12 PM Project: HVAC Frame Addition (Simple Frame Units system: English POGGEMEYE NV el Cons 512 6th Street So (425) 827- • le FAX: '',... IGN GROUP eers R' .ion 202 • Kirkland, WA 98033 (425) 828-4850 (BUILDING C) Made by BSF Date 6/18/08 Job Na 8035 Checked by Date Sheet No. S-2 Description HVAC FRAME ADDITION , Job Name DIGITAL FOREST i iJ a • I a° ii"" 4V ' 00 4 ) 5 ' 4114 7 i 7-7-7 .51 ft— _ s c 104 VNVf t,o CN MN -3 vr'll tullA R14. RCI.Ov vt.ttn6 441000 105 69/ AND pcetti A r4 t&iti G. TS 4x4 74 - POST, TYP CONL. 5E,A TYP > 1 304' 4 5r = o Pbr vi) 16% wry tot ID q coat,. a Pt,F p>4 et,e ifro (^ 1 fl Win% lAr4 63 t'borAid.-)6 (h/F 8035-S1.dwg Ben Fisher From: Harbison, Larry [larry.harbison @macmiller.com] Sent: Wednesday, June 18, 2008 7:32 AM To: Sheeks, Jared; Ben Fisher Cc: kevint @forest.net; Flink, Steve Subject: RE: Roof Question FYI The concrete slab was 4" thick From: Sheeks, Jared Sent: Tuesday, June 17, 2008 5:36 PM To: Ben Fisher Cc: kevint @forest.net; Flink, Steve; Harbison, Larry Subject: RE: Roof Question Ben, AHU -3 base weight is about 4500 Ib. If you use 6000 for the unit, curb, and accessories, I think you would be okay. -Jared 6/18/2008 POGGEMEYER DESIGN GROUP CONSULTING ENGINEERS 512 Sixth Street South, Suite 202 • Kirkland, WA 98033 (425) 827 -5995 • Fax (425) 828 -4850 Made by Date b I I5 6/ o Job No. Checked by Date Sheet No. 1 v ,c'� Description Job Name pilot m ` ft116 ;top t _ ,I,t_ " 3 — 1.1 k -2).114 '3.s3k - -1 INA AA &i4-0 D (t-pe-t 05 2 - q ) O PLR^^ Z- 3 (w2`(x55 5 =3 " • t3E Ani■ 3 _ w 2E4 YS 5 = 3d` - o ") DV Loh 301 VNT' 411111(/ . 3 2 G•tW'�. 0EG1 to f*e Coot/ 4 - &P M6uIFlN1Utti c lbo r 'pJOtj liAQ" 1 = 15 ?1 P 1 'v ta' - o i. Y •1 V' _ itu cq� /) ((.2 °(o) Nilo) 3p -pr 5 0trwt SFttfr (1-1r- o" .r-I)) (W-0" 97) 1', ? 9• P r © 1 we ' H1_1 °lo) ,Jor-1n 5Ht Ft- ifia = C0.02 p + 0. 025 K f_ )(2.3' -0 ") - toyt3 K o ¢ t D•t, t<pP O.% Kph + 011/7 K9f + 0•I01, 4 0.575 Kt! 1.033 l `o f -WgA,tu•.sE - BSF .x - 1.603k/ft 15. Member Code Checks Displayed Loads: LC 1, STATIC LC Results for LC 2, S -SHIFT LC Member Bending Moments (k -ft) Reaction units are k and k -ft Poggemeyer Design Group 1 -120.9 v - 1.603k/ft v A►SA ASA$.w$A$$e t. $A4i$In.As +10 A ►$Ae A$$ ► +A :sAt$1Att..Amho 19.7 39.8 BEAMS 2-4 GRID C STATIC LC -163.1 1( Code Check No Calc > -.0 .sa1.o .75 -.so .50=.75 June 18, 2008 at 1:35 PM HVAC GRID 2 -4.r2d IZ - 1.044k/ft Member Code Checks Displayed Loads: LC 2, S -SHIFT LC Results for LC 2, S -SHIFT LC Member Bending Moments (k -ft) Reaction units are k and k -ft Poggemeyer Design Group BSF -120.9 - 1.044k/ft 9k -2 9 1AASAWAI LS11IIMAWASASA$At . V11DAS1/A'LAtt A ACWASAM 159N 39.8 \_ BEAMS 2-4 GRID C S -SHIFT LC -163.1 Code Check No Calc > 1.0 .90 -1.0 .75.90 50.75 0. -.50 19.7 June 18, 2008 at 1:35 PM HVAC GRID 2 -4.r2d - 1.044k/ft - 1.044k/ft Member Code Checks Displayed Loads: LC 3, N -SHIFT LC Results for LC 3, N -SHIFT LC Member Bending Moments (k -ft) Reaction units are k and k -ft -5 5 -3.9k 11.11OS A W.N./...1. ► AAW.1.A. +.1.1.1.WAWA ASIA LOA .1.1.f ►:.tWA/. t 1 , 15.8\ 39.2 Poggemeyer Design Group BSF -119.7 -163.5 BEAMS 2-4 GRID C N -SHIFT LC Code Check No Calc >1.0 .90-1.0 75-.90 .50 -.75 0. -.50 20.4 June 18, 2008 at 1:35 PM HVAC GRID 2 -4.r2d 1 3I earn. al Shape: W24X55 Material: A572 Gr.50 Length: 30 ft I Joint: N1 J Joint: N2 LC 1: STATIC LC Code Check: 0.581 (bending) Report Based On 97 Sections fa ksi 19.174 at 15 ft ksi - 19.174 at 15 ft ksi A k 24.225 at O ft 1 „ lwuuu R llIIIIIIII111111 IIH O - 26.865 at 30 ft - 183.037 at 15 ft k -ft -.76 at 15 ft in B AISC ASD 9th Ed. Max Bending Check Location Equation Compact Fy 50 ksi Fa 2.07 ksi Ft 30 ksi Fb 33 ksi Fv 18.837 ksi Cb 1 Code Check 0.581 15ft H1 -1 Cm Lb KUr Sway Max Shear Check 0.153 Location 30 ft Max Defl Ratio U474 Out Plane 30 ft 268.605 No L Comp Flange 3.75 ft In Plane 1 30 ft 39.436 No B eam: M9 Shape: W24X55 Material: A572 Gr.50 Length: 30 ft Joint: N1 J Joint: N2 LC 2: S -SHIFT LC Code Check: 0.384 (bending) Report Based On 97 Sections fa ksi 12.67 at 15.312 ft ksi -12.67 at 15.312 ft ksi A k 15.89at0ft 111111111111iiiiikimmimin in - 19.322 at 30 ft - 120.948 at 15.312 ft k -ft -.503 at 15 ft in MSC ASD 9th Ed. Code Check Max Bending Check 0.384 Location 15.313 ft Equation H1 -1 Compact Max Shear Check 0.110 Location 30 ft Max Defl Ratio L/715 Fy 50 ksi Out Plane In Plane Fa 2.07 ksi Cm 1 Ft 30 ksi Lb 30 ft 30 ft Fb 33 ksi KUr 268.605 39.436 Fv 18.837 ksi Sway No No Cb 1 L Comp Flange 3.75 ft B eam. MI Shape: W24X55 Material: A572 Gr.50 Length: 30 ft I Joint: NI J Joint: N2 LC 3: N -SHIFT LC Code Check: 0.380 (bending) Report Based On 97 Sections fa ksi 12.536 at 15 ft ksi - 12.536 at 15 ft ksi A k 15.806 at O ft - 18.005 at 30 ft - 119.666 at 15 ft k -ft -.497 at 15 ft in AISC ASD 9th Ed. Code Check Max Bending Check Location Equation Compact Fy 50 ksi Fa 2.07 ksi Ft 30 ksi Fb 33 ksi Fy 18.837 ksi Cb 1 0.380 15ft H2 -1 Cm Lb 30 ft KUr 268.605 Sway No Max Shear Check 0.103 Location 30 ft Max Defl Ratio U724 Out Plane L Comp Flange 3.75 ft In Plane 1 30 ft 39.436 No eam: M2 Shape: W24X55 Material: A572 Gr.50 Length: 30 ft I Joint: N2 J Joint: N3 LC 1: STATIC LC Code Check: 0.708 (bending) Report Based On 97 Sections fa ksi 23.364 at 14.375 ft ksi - 23.364 at 14.375 ft ksi A k 28.905 at O ft 11111111111111111111111111111111111111111 Hu° °niiomllllllllllflllllh1111 - 28.185 at 30 ft - 223.037 at 14.375 ft k -ft -.921 at 15 ft in B AISC ASD 9th Ed. Max Bending Check Location Equation Compact Fy 50 ksi Fa 2.07 ksi Ft 30 ksi Fb 33 ksi Fv 18.837 ksi Cb 1 Code Check 0.708 14.375 ft H1 -1 Cm Lb KUr Sway Max Shear Check 0.165 Location 0 ft Max Defl Ratio U391 Out Plane 30 ft 268.605 No L Comp Flange 3.75 ft In Plane 1 30 ft 39.436 No 1-7 eam. M2 Shape: W24X55 Material: A572 Gr.50 Length: 30 ft I Joint: N2 J Joint: N3 LC 2: S -SHIFT LC Code Check: 0.518 (bending) Report Based On 97 Sections fa ksi 17.083 at 13.437 ft ksi - 17.083 at 13.437 ft ksi A k 20.49 at 0 ft I - 19.721 at 30 ft - 163.079 at 13.437 ft k -ft -.666 at 15 ft in B AISC ASD 9th Ed. Max Bending Check Location Equation Compact Fy 50 ksi Fa 2.07 ksi Ft 30 ksi Fb 33 ksi Fv 18.837 ksi Cb 1 Code Check 0.518 13.438 ft H2 -1 Cm Lb 30 ft KL /r 268.605 Sway No Max Shear Check 0.117 Location 0 ft Max Defl Ratio L/541 Out Plane L Comp Flange 3.75 ft In Plane 1 30 ft 39.436 No is eam. M2 Shape: W24X55 Material: A572 Gr.50 Length: 30 ft I Joint: N2 J Joint: N3 LC 3: N -SHIFT LC Code Check: 0.519 (bending) Report Based On 97 Sections fa ksi 17.13 at 14.063 ft ksi -17.13 at 14.063 ft ksi A k 21.19 at 0 ft . n^inliwIMIVR1111111 - 20.421 at 30 ft - 163.519 at 14.063 ft k -ft -.679 at 15 ft in B AISC ASD 9th Ed. Max Bending Check Location Equation Compact Fy 50 ksi Fa 2.07 ksi Ft 30 ksi Fb 33 ksi Fv 18.837 ksi Cb 1 Code Check 0.519 14.063 ft H1 -1 Cm Lb KUr Sway Max Shear Check 0.121 Location 0 ft Max Defl Ratio U530 Out Plane 30 ft 268.605 No L Comp Flange 3.75 ft In Plane 1 30 ft 39.436 No POGGEMEYER DESIGN GROUP CONSULTING ENGINEERS 512 Sixth Street South, Suite 202 • Kirkland, WA 98033 (425( 827 -5995 • Fax (425( 828 -4850 Made by �� Date / /lg l b g (� • Job No. Qo 3 S" Checked by Date Sheet No. 70 � Description Job Name VI It t t, F• 28s t 3&AM 6ttivJ P e C4 N t oS Ps) 9e4m i t- Y ( `f)e t. s o.W - aw) 1,6,11m.1,4 tJE G 0 L OA E Mi 06t&1 ° Za Fir (2S 'M t& 2. `1" Goat. 7eAr- ' 1413 f�F. tot 6PMAntiGltl 16o 'Lf u9AQ•, -)a : as- QSe. (23`-0" T -t3) WR (WM MMI %) 35' -0" PPir 5rn-n S - 441Er 1 - '3-V4 5 • N -sH�Fr -. 333 -1.00( _3 -3.1v Ky� F r k of of WA ; (0.02 v i o•01� ,, )(24 -n ) i Olft „ i D. lh e 0 K d F •+ 0.9,5 KL - 1.603k /ft ASO # 4PA$1A4A 1SA$ A A $,iAi i t' i A A A Member Code Checks Displayed Loads: LC 1, STATIC LC Results for LC 1, STATIC LC Member Bending Moments (k -ft) Reaction units are k and k -ft Poggemeyer Design Group BSF -268 BEAMS 4 -5 GRID C STATIC LC HVAC GRID 4 -5.2d Code Check No Cale > 1.0 .90-1.0 .75-90 .50 -.75 0. -.50 z l June 18, 2008 at 1:32 PM .X - 1.044k/ft .11WAWAW1 L W1SAAW1WAVAMMAWMA IMAWASAWA itttli 19.8 Member Code Checks Displayed Loads: LC 2, S -SHIFT LC Results for LC 2, S -SHIFT LC Member Bending Moments (k -ft) Reaction units are k and k -ft Poggemeyer Design Group BSF -187.4 k BEAMS 4 -5 GRID C S -SHIFT LC 2,5( Code Check No Calc > 1.0 .90 -1.0 .75 -.90 50- 75 0,50 23.2 June 18, 2008 at 1:32 PM HVAC GRID 4 -5.r2d z3 -1 044k/ft 11. 1,. 1. 1, 11. 1. N► .y.1/,.!S.1.S$15.1.1.W.$SI I MAMA .1.41.4.41.1.$1111AS i.1.1. (1. Member Code Checks Displayed Loads: LC 3, N -SHIFT LC Results for LC 3, N -SHIFT LC Member Bending Moments (k -ft) Reaction units are k and k -ft Poggemeyer Design Group BSF -181.1 BEAMS 4 -5 GRID C N -SHIFT LC Code Check No Cale > 1.0 .90 -1.0 .75 -.90 .50 -.75 0:.50 June 18, 2008 at 1:32 PM HVAC GRID 4 -5.r2d eam. M2 Shape: W24X55 Material: A572 Gr.50 Length: 35 ft I Joint: N2 J Joint: N3 LC 1: STATIC LC Code Check: 0.851 (bending) Report Based On 97 Sections fa ksi 28.075 at 18.229 ft ksi - 28.075 at 18.229 ft ksi A k 29313at0ft - 32.792 at 35 ft - 268.002 at 18.229 ft k -ft -1.514 at 17.5 ft in B AISC ASD 9th Ed. Max Bending Check Location Equation Compact Fy 50 ksi Fa 1.521 ksi Ft 30 ksi Fb 33 ksi Fv 18.829 ksi Cb 1 Code Check 0.851 18.229 ft H1 -1 Cm Lb 35 ft KUr 313.372 Sway No Max Shear Check 0.187 Location 35 ft Max Defl Ratio U277 Out Plane L Comp Flange 3.75 ft In Plane 1 35 ft 46.009 No zq t eam. M2 Shape: W24X55 Material: A572 Gr.50 Length: 35 ft I Joint: N2 J Joint: N3 LC 2: S -SHIFT LC Code Check: 0.595 (bending) Report Based On 97 Sections fa ksi 19.628 at 18.958 ft ksi - 19.628 at 18.958 ft ksi A k 19.777 at 0 ft .,o I ... a���un i m��N p sl - 23.153 at 35 ft - 187.372 at 18.958 ft k -ft o � -1.057 at 17.865 ft in AISC ASD 9th Ed. Max Bending Check Location Equation Compact Fy 50 ksi Fa 1.521 ksi Ft 30 ksi Fb 33 ksi Fv 18.829 ksi Cb 1 Code Check 0.595 18.958 ft H2 -1 Cm Lb KUr Sway Max Shear Check 0.132 Location 35 ft Max Defl Ratio U397 Out Plane 35 ft 313.372 No L Comp Flange 3.75 ft In Plane 1 35 ft 46.009 No t3 eam: M2 Shape: W24X55 Material: A572 Gr.50 Length: 35 ft I Joint: N2 J Joint: N3 LC 3: N -SHIFT LC Code Check: 0.575 (bending) Report Based On 97 Sections fa ksi 18.967 at 18.594 ft ksi - 18.967 at 18.594 ft ksi A k 19.441 at 0 ft I ...., " ,, oulllilllfll {iII11Il - 23.489 at 35 ft - 181.059 at 18.594 ft k -ft - 1.025 at 17.865 ft in AISC ASD 9th Ed. Max Bending Check Location Equation Compact Fy 50 ksi Fa 1.521 ksi Ft 30 ksi Fb 33 ksi Fv 18.829 ksi Cb 1 Code Check 0.575 18.594 ft H1 -1 Max Shear Check 0.134 Location 35 ft Max Defl Ratio L /410 Out Plane Cm Lb 35 ft KL /r 313.372 Sway No L Comp Flange 3.75 ft In Plane 1 35 ft 46.009 No 2 b POGGEMEYER DESIGN GROUP CONSULTING ENGINEERS 512 Sixth Street South, Suite 202 • Kirkland, WA 98033 (425) 827 -5995 • Fax (425) 82814850 Made by l� Dare b I i 0 $ Job No. $o3Y Checked by Date Sheet No. 17 Description Job Name h (Xii* _ ri - _ I "3 -33' r t ti k `3.1 3. ;3k - 3.q`` - 1.1 1 ` 1 (.4 Gt a- v? F 660.4 o5 '5 - 7-) • P,ERAk y - -1, ( w 147e S 5 3o' -.9") L -1 C W2'f c 5 51. 30 -0 ") • 9,e ti t- lµ Olen, oCcid. 2 ?AI r LP' cow,. ct,h 9 i{/ kcv 1.1.0144 14,0et,r mow Gv A O vk = •¢ P4 r Far I 2 =� 3 Si [t L `I 5 O1•" S I (PR = (0.0)4 fi } d OVL 1`F)( 1,041) 1•01 491 f V• V KL , �GI9 MNr■16 If ok tq 5 Eh Pr 4 0/ 0.1e BSF Y z —.x - 1.03k /ft -3k AAAi 4. A A AA A•AA Member Code Checks Displayed Loads: LC 1, STATIC LC Results for LC 1, STATIC LC Member Bending Moments (k -ft) Reaction units are k and k -ft Poggemeyer Design Group -3k -3k -149.5 BEAMS 5 -7 GRID C STATIC LC -117.2 29 Code Check No Calc > 1.0 90-1.0 75- 90 50-.75 0 -.50 15.5 June 18, 2008 at 1:43 PM HVAC GRID 5 -7.r2d Y -0 .Z - -. -3.9k Member Code Checks Displayed Loads: LC 2, S -SHIFT LC Results for LC 2, S -SHIFT LC Member Bending Moments (k -ft) Reaction units are k and k -ft Poggemeyer Design Group BSF -94/ -3.9k •12!• •••411 ■••■■•■■ . BEAMS 5 -7 GRID C S -SHIFT LC HVAC GRID 5 -7.r2d Code Check No Calc > 1.0 .90 -1.0 .75.90 .50 -.75 0 -.50 June 18, 2008 at 1:44 PM iz -. - .528k/ft -2.5k 13. Member Code Checks Displayed Loads: LC 3, N -SHIFT LC Results for LC 3, N -SHIFT LC Member Bending Moments (k -ft) Reaction units are k and k -ft Poggemeyer Design Group BSF -3.9k -3.9k AAA. A AA• A ti•A VA•AAAAAAAALLL 4AA J., AAAAA Ant -96.7 -2.5k - .528k/ft / 23.3\ BEAMS 5 -7 GRID C N -SHIFT LC -61.2 30 Code Check No Calc > 1.0 .90 -1.0 .75- 90 .50-.75 0:.50 June 18, 2008 at 1:44 PM HVAC GRID 5 -7.r2d eam: MI Shape: W24X55 Material: A572 Gr.50 Length: 30 ft I Joint: N1 J Joint: N2 LC 1: STATIC LC Code Check: 0.474 (bending) Report Based On 97 Sections fa ksi 15.657 at 14.375 ft ksi - 15.657 at 14.375 ft ksi A k 20.67 at 0 ft nuII milli1111111111 -19.23 at 30 ft - 149.461 at 14.375 ft k -ft -.623 at 15 ft in B AISC ASD 9th Ed. Code Check Max Bending Check 0.474 Location 14.375 ft Equation H2 -1 Compact Max Shear Check 0.118 Location 0 ft Max Defl Ratio U578 Fy 50 ksi Out Plane In Plane Fa 2.07 ksi Cm 1 Ft 30 ksi Lb 30 ft 30 ft Fb 33 ksi KUr 268.605 39.436 Fv 18.837 ksi Sway No No Cb 1 L Comp Flange 3.75 ft eam. M1 Shape: W24X55 Material: A572 Gr.50 Length: 30 ft I Joint: N1 J Joint: N2 LC 2: S -SHIFT LC Code Check: 0.301 (bending) Report Based On 97 Sections fa ksi 9.921 at 14.063 ft ksi -9.921 at 14.063 ft ksi A k 13.852 at O ft " illiti I (ilIIIIUU►[hI I I I IIIIIII - 12.288 at 30 ft - 94.707 at 14.063 ft k -ft -.399 at 15 ft in B AISC ASD 9th Ed. Code Check Max Bending Check 0.301 Location 14.063 ft Equation H2 -1 Compact Max Shear Check 0.079 Location 0 ft Max Defl Ratio L/901 Fy 50 ksi Out Plane In Plane Fa 2.07 ksi Cm 1 Ft 30 ksi Lb 30 30 ft Fb 33 ksi KUr 268.605 39.436 Fv 18.837 ksi Sway No No Cb 1 L Comp Flange 3.75 ft 3a earn. MI Shape: W24X55 Material: A572 Gr.50 Length: 30 ft I Joint: N1 J Joint: N2 LC 3: N -SHIFT LC Code Check: 0.307 (bending) Report Based On 97 Sections fa ksi 10.129 at 12.813 ft ksi - 10.129 at 12.813 ft ksi A k 13.124 at O ft 1111111111htenkim _ ... � , oi�uo W A III� II � n IUN� - 11.616 at 30 ft - 96.693 at 12.813 ft k -ft -.398 at 15 ft in B AISC ASD 9th Ed. Code Check Max Bending Check 0.307 Location 12.813 ft Equation H1 -1 Compact Max Shear Check 0.075 Location 0 ft Max Defl Ratio L/906 Fy 50 ksi Out Plane In Plane Fa 2.07 ksi Cm 1 Ft 30 ksi Lb 30 ft 30 ft Fb 33 ksi KL /r 268.605 39.436 Fv 18.837 ksi Sway No No Cb 1 L Comp Flange 3.75 ft 33 b eam. M2 Shape: W24X55 Material: A572 Gr.50 Length: 30 ft I Joint: N2 J Joint: N3 LC 1: STATIC LC Code Check: 0.372 (bending) Report Based On 97 Sections fa ksi 12.28 at 15 ft ksi -12.28 at 15 ft ksi A k 18.36 at 0 ft 0 m wI „ I mm , ii iillllli lll ll l l ll1 l -15.54 at 30 ft - 117.225 at15ft k -ft -.486 at 15 ft in A /SC ASD 9th Ed. Max Bending Check Location Equation Compact Fy 50 ksi Fa 2.07 ksi Ft 30 ksi Fb 33 ksi Fv 18.837 ksi Cb 1 Code Check 0.372 15ft H2 -1 Max Shear Check 0.105 Location 0 ft Max Defl Ratio U740 Out Plane Cm Lb 30 ft KUr 268.605 Sway No L Comp Flange 3.75 ft In Plane 1 30 ft 39.436 No t eam. M2 Shape: W24X55 Material: A572 Gr.50 Length: 30 ft I Joint: N2 J Joint: N3 LC 2: S -SHIFT LC Code Check: 0.192 (bending) Report Based On 97 Sections fa ksi 6.34 at 15 ft ksi -6.34 at 15 ft ksi A k 10.345 at 0 ft 1 11 1 1 1 1 1 1 1I l li kaillim innh. ^„ flw -7.995 at 30 ft - 60.525 at 15 ft k -ft -.251 at 15 ft in AISC ASD 9th Ed. Max Bending Check Location Equation Compact Fy 50 ksi Fa 2.07 ksi Ft 30 ksi Fb 33 ksi F■ 18.837 ksi Cb 1 Code Check 0.192 15ft H1 -1 Cm Lb KL/r Sway L Comp Flange Max Shear Check 0.059 Location 0 ft Max Defl Ratio L/1432 Out Plane 30 ft 268.605 No 3.75 ft In Plane 1 30 ft 39.436 No 3s eam: 1V/ Shape: W24X55 Material: A572 Gr.50 Length: 30 ft I Joint: N2 J Joint: N3 LC 3: N -SHIFT LC Code Check: 0.194 (bending) Report Based On 97 Sections fa ksi 6.407 at 14.688 ft ksi -6.407 at 14.688 ft ksi A k 11.703at0ft 111 11111 11i111111111imamith .. uI � m ���ellll�uulIIIIIIIIIIIIIIIIIIII) -8.037 at 30 ft - 61.166 at 14.688 ft k -ft -.254 at 15 ft in B AISC ASD 9th Ed. Code Check Max Bending Check 0.194 Location 14.688 ft Equation H2 -1 Compact Max Shear Check 0.067 Location 0 ft Max Defl Ratio L/1415 Fy 50 ksi Out Plane In Plane Fa 2.07 ksi Cm 1 Ft 30 ksi Lb 30 ft 30 ft Fb 33 ksi KL /r 268.605 39.436 Fv 18.837 ksi Sway No No Cb 1 L Comp Flange 3.75 ft POGGEMEYER DESIGN GROUP CONSULTING ENGINEERS 512 Sixth Street South, Suite 202 • Kirkland, WA 98033 (425) 827 -5995 • Fax (425) 828-4850 Made by $5 `3.1 Date r,/tt(Og Job No. 9o34; Checked by Date Sheet No. 3 c/ Description Job Name Ptct.try0 RODP UJrgt � W4it, ! ,,/ r24%Yo Q r1 RJAfi cAA4 - 3.33 + II k `3.1 "3.;3 -1).(11` - ii. 9K 4ate P Ctfi''o 2-'{) •SEAM 2 -3 (1•0t$x3b' ,t 3o' -O'") ® be M 3 .4 (wt 8)('r 5= 301.0.9 p 2 - � Q L. „A. E'N, L . 961.t = 20 Py it W' gNo vv GoA = ?K piF 11U(b Loh 2`b' -'1 30 - 0 9 piyrntrb. LOA0 n..) P6A (13i -6 ")( 0.02 Kt( 5O✓v% ;Kt Fr 5 Nt pr r/YiA li'^)v 1 ) P, ?1 93 Pq I If W a �, (g1 -$„ `l. ,�., Di. ,�„ � .. fi r. 4'4 (9'1 /o) (22 °0 ('tit lob oZ°M o'- oft Z - 3 = ( 0• o2 I t 0 .02 1 : t2(41My. (A)A0 Oc' bOm 3- 4 •' (5 g`i)(p. o2 (C f a 0.b25 ) (o. f ) e ' + o. to I P) =au kD t o. 15 Kt' BSF Member Code Checks Displayed Loads: LC 1, STATIC LC Results for LC 1, STATIC LC Member Bending Moments (k -ft) Reaction units are k and k -ft Poggemeyer Design Group -118.9 36.9 ` BEAMS 2 -3 AND 3 -4 STATIC LC -144.6 June 17, 2008 at 3:12 PM HVAC GRID 2 -4.r2d Code Check No Calc > 1.0 .90 -1.0 .75.90 50-.75 0. -.50 - 7 .x - .528k/ft 1 •AAAIN A AAAAA AA••: AI • •• AAA AAAAAAA AA IAAAAAA A Member Code Checks Displayed Loads: LC 2, S -SHIFT LC Results for LC 2, S -SHIFT LC Member Bending Moments (k -ft) Reaction units are k and k -ft -4.9k 8.2'` 26 Poggemeyer Design Group BSF -63.9 -3.9k BEAMS 2 -3 AND 3 -4 S -SHIFT LC -4.9k -113.3 -3.9k HVAC GRID 2 -4.r2d 12.4 3g Code Check No Calc > 7.0 .90-1.0 .75 -.s0 50.75 0:.50 June 17, 2008 at 3:16 PM BSF - .528k/ft AAA A• 1A1jAAAA ALL 11A -A •AAAAAA•A••• 8.2 Member Code Checks Displayed Loads: LC 3, N -SHIFT LC Results for LC 3, N -SHIFT LC Member Bending Moments (k -ft) Reaction units are k and k -ft Poggemeyer Design Group -63 -4.9k -3.9k -3.9k 2 A 25.5 BEAMS 2 -3 AND 3 -4 N -SHIFT LC -113.5 j' 12.9 -4.9k Code Check I No Calc > 1.0 90-1.0 .75 -.90 50.75 0 -.50 June 17, 2008 at 3:12 PM HVAC GRID 2 -4.r2d eam. MI Shape: W18X35 Material: A572 Gr.50 Length: 30 ft I Joint: N1 J Joint: N2 LC 1: STATIC LC Code Check: 0.750 (bending) Report Based On 97 Sections fa ksi 24.756 at 15.312 ft ksi - 24.756 at 15.312 ft ksi A k 1565atOft ....,,,,, � uII � iI IIllllll 111 �I��I��l1lli�l -18.58 at 30 ft - 118.884 at 15.312 ft k -ft -1.308 at 15 ft in B AISC ASD 9th Ed. Max Bending Check Location Equation Compact Fy 50 ksi Fa 1.712 ksi Ft 30 ksi Fb 33 ksi Fv 19.142 ksi Cb 1 Code Check 0.750 15.313 ft H1 -1 Max Shear Check 0.183 Location 30 ft Max Defl Ratio L/275 Out Plane In Plane Cm 1 Lb 30 ft 30 ft KL/r 295.376 51.161 Sway No No L Comp Flange 3.75 ft 140 B eam. M1 Shape: W18X35 Material: A572 Gr.50 Length: 30 ft I Joint: N1 J Joint: N2 LC 2: S -SHIFT LC Code Check: 0.403 (bending) Report Based On 97 Sections fa ksi 13.304 at 15.625 ft ksi - 13.304 at 15.625 ft ksi A k 8 214 at 0 ft mannIIIICIIIIIliii(11111I) t - 12.526 at 30 ft -63.891 at 15.625 ft k -ft -.708 at 15.312 ft in AISC ASD 9th Ed. Code Check Max Bending Check 0.403 Location 15.625 ft Equation H2 -1 Compact Fy 50 ksi Fa 1.712 ksi Ft 30 ksi Fb 33 ksi Fv 19.142 ksi Cb 1 Cm Lb 30 ft KUr 295.376 Sway No Max Shear Check 0.123 Location 30 ft Max Defl Ratio U508 Out Plane L Comp Flange 3.75 ft In Plane 1 30 ft 51.161 No II I eam. MI Shape: W18X35 Material: A572 Gr.50 Length: 30 ft I Joint: N1 J Joint: N2 LC 3: N -SHIFT LC Code Check: 0.397 (bending) Report Based On 97 Sections fa ksi 13.11 at 15.312 ft ksi -13.11 at 15.312 ft ksi A k 8 154 at 0 ft IIIIIIIIIIIIIIII���IIIIIIIIIIIIII IIIIIIIIIDIiII�IIIIIIIIII III - 11.586 at 30 ft - 62.957 at 15.312 ft k -ft -.697 at 15 ft in AISC ASD 9th Ed. Max Bending Check Location Equation Compact Fy 50 ksi Fa 1.712 ksi Ft 30 ksi Fb 33 ksi Fv 19.142 ksi Cb 1 Code Check 0.397 15.313 ft H2 -1 Max Shear Check 0.114 Location 30 ft Max Defl Ratio U517 Out Plane Cm Lb 30 ft KUr 295.376 Sway No L Comp Flange In Plane 1 30 ft 51.161 No 3.75 ft B eam. M2 Shape: W18X35 Material: A572 Gr.50 Length: 30 ft I Joint: N2 J Joint: N3 LC 1: STATIC LC Code Check: 0.913 (bending) Report Based On 97 Sections fa ksi 30.117 at 13.437 ft ksi - 30.117 at 13.437 ft ksi A k 18.295 at O ft 111111 - 17.495 at 30 ft - 144.63 at 13.437 ft k -ft - 1.574 at 15 ft in AISC ASD 9th Ed. Max Bending Check Location Equation Compact Fy 50 ksi Fa 1.712 ksi Ft 30 ksi Fb 33 ksi Fv 19.142 ksi Cb 1 Code Check 0.913 13.438 ft H1 -1 Max Shear Check 0.180 Location 0 ft Max Defl Ratio L1229 Out Plane Cm Lb 30 ft KUr 295.376 Sway No L Comp Flange 3.75 ft In Plane 1 30 ft 51.161 No 11 3 eam. M Shape: W18X35 Material: A572 Gr.50 Length: 30 ft I Joint: N2 J Joint: N3 LC 2: S -SHIFT LC Code Check: 0.715 (bending) Report Based On 97 Sections fa ksi 23.6 at 13.437 ft ksi -23.6 at 13.437 ft ksi A k 13.448at0ft - 12.392 at 30 ft - 113.333 at 13.437 ft k -ft -1.206 at 15 ft in B AISC ASD 9th Ed. Max Bending Check Location Equation Compact Fy 50 ksi Fa 1.712 ksi Ft 30 ksi Fb 33 ksi Fv 19.142 ksi Cb 1 Code Check 0.715 13.438 ft H1 -1 Cm Lb 30 ft KUr 295.376 Sway No Max Shear Check 0.132 Location 0 ft Max Defl Ratio L1298 Out Plane L Comp Flange 3.75 ft In Plane 1 30 ft 51.161 No 1/1 eam: M2 Shape: W18X35 Material: A572 Gr.50 Length: 30 ft I Joint: N2 J Joint: N3 LC 3: N -SHIFT LC Code Check: 0.716 (bending) Report Based On 97 Sections fa ksi 23.625 at 13.437 ft ksi - 23.625 at 13.437 ft ksi A k 13.948 at 0 ft 11111111111 IIIIIMM1111111a_...,...mmilimill111111111111 - 12.892 at 30 ft - 113.452 at 13.437 ft k -ft -1.232 at 15 ft in B AISC ASD 9th Ed. Max Bending Check Location Equation Compact Fy 50 ksi Fa 1.712 ksi Ft 30 ksi Fb 33 ksi Fv 19.142 ksi Cb 1 Code Check 0.716 13.438 ft H2 -1 Cm Lb 30 ft KUr 295.376 Sway No Max Shear Check 0.137 Location 0 ft Max Defl Ratio L1292 Out Plane L Comp Flange 3.75 ft In Plane 1 30 ft 51.161 No POGGEMEYER DESIGN GROUP CONSULTING ENGINEERS 512 Sixth Street South. Suite 202 • Kirkland, WA 98033 (425) 827 -5995 • Fax (425) 828 -4850 Made by 80>p Date b/14(D$ Job No. IP 3S" Checked by Date Sheet No. / / / l� Description Job Name t7 (Q(Crtt. 6n641 [toot KJkL kit tit F-1 PtiocoSEQ AM—t— GDR os 3.33k - '1•q'` -3,1t` .- $. -3 .1 1( q. aK . J 156 AM /(/V� /P � C Lti o Y) • BEA'A 'f -Y 6.0 p( S 2. Dl, Pterott pew- = 20 r5 F t,1, ' /Jar., Lc, to4 = 21 4 '4 P P 3t_g11 (o.b2_ to ; t t.025 L = O. o K o f * 0.53. if - N -Skiff PeAnnu,ts, T) DIyt. (,,AO N ( AM 1 -Y g Ca ")(O. t D.ozY' ) f (!3 -6")• .X - 1.03k /ft Loads: LC 1, STATIC LC Results for LC 1, STATIC LC Member Bending Moments (k -ft) Reaction units are k and k -ft Poggemeyer Design Group BSF -183.1 BEAM 4 -5 STATIC LC -3.33k -3.33k June 17, 2008 at 3:11 PM HVAC GRID 4 -5.r2d 1 /7 Section Sets na L/ -4.9k A••4 11••A.A•• Loads: LC 2, S -SHIFT LC Results for LC 2, S -SHIFT LC Member Bending Moments (k -ft) Reaction units are k and k -ft Poggemeyer Design Group BSF -119 BEAM 4 -5 S -SHIFT LC Section Sets na June 17, 2008 at 3:11 PM HVAC GRID 4 -5.r2d - .528k /ft AAAAkAk AvAk.A iAAuAAAAkkA Loads: LC 3, N -SHIFT LC Results for LC 3, N -SHIFT LC Member Bending Moments (k -ft) Reaction units are k and k -ft Poggemeyer Design Group BSF BEAM 4 -5 N -SHIFT LC -3.9k -4.9k June 17, 2008 at 3:16 PM HVAC GRID 4 -5.r2d 49 eam. M2 Shape: W24X55 Material: A572 Gr.50 Length: 35 ft I Joint: N2 J Joint: N3 LC 1: STATIC LC Code Check: 0.581 (bending) Report Based On 97 Sections fa ksi 19.185 at 18.958 ft ksi - 19.185 at 18.958 ft ksi A k 19.424 at 0 ft iHllll 1 �Niwcuq 1 11R111111111111 - 23.286 at 35 ft - 183.139 at 18.958 ft k -ft -1.035 at 17.865 ft in B AISC ASD 9th Ed. Code Check Max Bending Check 0.581 Location 18.958 ft Equation H1 -1 Compact Max Shear Check 0.133 Location 35 ft Max Defl Ratio L/406 Fy 50 ksi Out Plane In Plane Fa 1.521 ksi Cm 1 Ft 30 ksi Lb 35 ft 35 ft Fb 33 ksi KUr 313.372 46.009 Fv 18.829 ksi Sway No No Cb 1 L Comp Flange 3.75 ft 50 eam. M2 Shape: W24X55 Material: A572 Gr.50 Length: 35 ft I Joint: N2 J Joint: N3 LC 2: S -SHIFT LC Code Check: 0.378 (bending) Report Based On 97 Sections fa ksi 12.461 at 21.146 ft ksi - 12.461 at 21.146 ft ksi A k 11.208at0ft llIDDhIIIIIliiIiIIHllhiIIilII!tIHHI1111, ,,..... y��iuilloll�ltlllll��� - 16.072 at 35 ft - 118.956 at 21.146 ft k -ft -.661 at 18.229 ft in B AISC ASD 9th Ed. Max Bending Check Location Equation Compact Fy 50 ksi Fa 1.521 ksi Ft 30 ksi Fb 33 ksi Fv 18.829 ksi Cb 1 Code Check 0.378 21.146 ft H1 -1 Cm Lb 35 ft KL /r 313.372 Sway No Max Shear Check 0.092 Location 35 ft Max Defl Ratio L1636 Out Plane L Comp Flange 3.75 ft In Plane 1 35 ft 46.009 No eam. M2 Shape: W24X55 Material: A572 Gr.50 Length: 35 ft I Joint: N2 J Joint: N3 LC 3: N -SHIFT LC Code Check: 0.362 (bending) Report Based On 97 Sections fa ksi 11.934 at 20.781 ft ksi - 11.934 at 20.781 ft ksi A k 10.968 at 0 ft 111111111111illiiilmomolli.„„„,... - 16.312 at 35 ft - 113.918 at 20.781 ft k -ft -.638 at 17.865 ft in B RISC ASD 9th Ed. Max Bending Check Location Equation Compact Fy 50 ksi Fa 1.521 ksi Ft 30 ksi Fb 33 ksi Fv 18.829 ksi Cb 1 Code Check 0.362 20.781 ft H2 -1 Cm Lb KUr Sway Max Shear Check 0.093 Location 35 ft Max Defl Ratio U659 Out Plane 35 ft 313.372 No L Comp Flange 3.75 ft In Plane 1 35 ft 46.009 No 5Z POGGEMEYER DESIGN GROUP CONSULTING ENGINEERS 512 Sixth Street South, Suite 202 • Kirkland, WA 98033 (425) 827 -5995 • Fax (425) 828 -4850 Made by 35r Date c,/tt/o Job No. % o3S-- Checked by Date Sheet No 53 Description Job Name Pia trt art .4,41 ROOF 10/11. Uetitel r- c'o56Q E {JA' - L.D"pS "3.33`` - `f - - 3•1 t ` 3 -”'` -1).(114. - `f• 1 K 14t� 60-8.09 G (60,1o5 5 - • AM 5 - b (tJ ltb y, 3o' - ") • btR A (o (w18)(3< 5= 3oco - ) Ni P l 2 QL AE - PAL. ce - zoes 1 ,1, yNnuv WO = 7K Pit= „ f too O:c,ra 3 - t,oR o v..1 f*Ann ('1 310.02D p t 0 - 0 24 14 f (113 0.010 K f p.ov s t ! p Kpf 6.51 &F Qt41Mg. GotiO Or► b ►m 3 (5 Icg 4 p.b25 ) 61 ") (D -o2o ct F + o. ttir � = 0.36 if t o.1 g 149 1! 1 711111C/ 2. 3 ( (% °k) 30-o 501mt St4tFr (3' /o) r 3� tiviLilA 5 E4 Pr *„qty■ n)6. l0 5y BSF -3.33k - .86k/ft -3.33k -3.33k AAA • AAA•► ►. / •A—LAALAAA r/ AAAAku ••• £A•L.A4a.L AAAAAAAA••A &A Member Code Checks Displayed Loads: LC 1, STATIC LC Results for LC 1, STATIC LC Member Bending Moments (k -ft) Reaction units are k and k -ft Poggemeyer Design Group -134.1 BEAMS 5 -6 AND 6 -7 STATIC LC Code Check No Cato > 1.0 .90-1.0 .75 -.s0 .50 -.75 0. -.50 June 17, 2008 at 3:04 PM HVAC GRID 5 -7.r2d Y X - .438k/ft -4.9k Member Code Checks Displayed Loads: LC 2, S -SHIFT LC Results for LC 2, S -SHIFT LC Member Bending Moments (k -ft) Reaction units are k and k -ft -4.9k -3.9k -3.9k - .528k/ft -98.7 Poggemeyer Design Group BSF BEAMS 5 -6 AND 6 -7 S -SHIFT LC -61.2 HVAC GRID 5 -7.r2d 55 Code Check No Calc > 1.0 .90 -1.0 .75 -.90 .50-.75 0:.50 June 17, 2008 at 3:05 PM -3.9k -3.9k -.438k/ft 187, Member Code Checks Displayed Loads: LC 3, N -SHIFT LC Results for LC 1, STATIC LC Member Bending Moments (k -ft) Reaction units are k and k -ft Poggemeyer Design Group BSF -4.9k -134.1 -4.9k - .528k/ft N 35.8 BEAMS 5 -6 AND 6 -7 N -SHIFT LC -117.4 HVAC GRID 5 -7.r2d 5 l� Code Check No Cale > 1.0 .90 -1.0 .75 -.90 .50 -.75 0:.50 15.5 June 17, 2008 at 3:15 PM earn. M1 Shape: W18X35 Material: A572 Gr.50 Length: 30 ft, I Joint: N1 J Joint: N2 LC 1: STATIC LC Code Check: 0.846 (bending) Report Based On 97 Sections fa ksi 27.934 at 14.063 ft ksi - 27.934 at 14.063 ft ksi A k 18.694 at 0 ft H011 ifium°Il1111IIIII1111111111 - 17.096 at 30 ft - 134.147 at 14.063 ft k -ft -1.48 at 15 ft in B AISC ASD 9th Ed. Max Bending Check Location Equation Compact Fy 50 ksi Fa 1.712 ksi Ft 30 ksi Fb 33 ksi Fv 19.142 ksi Cb 1 Code Check 0.846 14.063 ft H2 -1 Max Shear Check 0.184 Location 0 ft Max Defl Ratio L1243 Out Plane Cm Lb 30 ft KUr 295.376 Sway No L Comp Flange 3.75 ft In Plane 1 30 ft 51.161 No 57 earn. Ml Shape: W18X35 Material: A572 Gr.50 Length: 30 ft I Joint: N1 J Joint: N2 LC 2: S -SHIFT LC Code Check: 0.623 (bending) Report Based On 97 Sections fa ksi 20.553 at 13.125 ft ksi - 20.553 at 13.125 ft ksi A k 14.486 at 0 ft 11111001111111111111MIIIIIIIIL - 12.354 at 30 ft '' imulmmlii1111111111111111111 - 98.703 at 13.125 ft k -ft -1.097 at 15 ft in B AISC ASD 9th Ed. Code Check Max Bending Check 0.623 Location 13.125 ft Equation H1-1 Compact Max Shear Check 0.143 Location 0 ft Max Defl Ratio L/328 Fy 50 ksi Out Plane In Plane Fa 1.712 ksi Cm 1 Ft 30 ksi Lb 30 ft 30 ft Fb 33 ksi KUr 295.376 51.161 Fv 19.142 ksi Sway No No Cb 1 L Comp Flange 3.75 ft 58 earn. M1 Shape: W18X35 Material: A572 Gr.50 Length: 30 ft I Joint: N1 J Joint: N2 LC 3: N -SHIFT LC Code Check: 0.635 (bending) Report Based On 97 Sections fa ksi 20.962 at 11.875 ft ksi - 20.962 at 11.875 ft ksi A k 13.966 at 0 ft - 11.874 at 30 ft - 100.664 at 11.875 ft k -ft - 1.094 at 14.688 ft in B AISC ASD 9th Ed. Max Bending Check Location Equation Compact Fy 50 ksi Fa 1.712 ksi Ft 30 ksi Fb 33 ksi Fy 19.142 ksi Cb 1 Code Check 0.635 11.875 ft H1 -1 Cm Lb 30 ft KL /r 295.376 Sway No Max Shear Check 0.137 Location 0 ft Max Defl Ratio L1329 Out Plane L Comp Flange 3.75 ft In Plane 1 30 ft 51.161 No 59 Beam. N12 Shape: W18X35 Material: A572 Gr.50 Length: 30 ft I Joint: N2 J Joint: N3 LC 1: STATIC LC Code Check: 0.741 (bending) Report Based On 97 Sections fa ksi 24.441 at 15 ft ksi - 24.441 at 15 ft ksi A k 18.68 at 0 ft h11111111111111101iimommilimun ... � ,,,,,, iumummilimIfIIIllllllilll -15.55 at 30 ft - 117.374 at 15 ft k -ft -1.289 at 15 ft in AISC ASD 9th Ed. Code Check Max Bending Check 0.741 Max Shear Check 0.184 Location 15 ft Location 0 ft Equation H1 -1 Max Defl Ratio U279 Compact Fy 50 ksi Out Plane In Plane Fa 1.712 ksi Cm 1 Ft 30 ksi Lb 30 ft 30 ft Fb 33 ksi KUr 295.376 51.161 Fv 19.142 ksi Sway No No Cb 1 L Comp Flange 3.75 ft b 6 earn: M Shape: W18X35 Material: A572 Gr.50 Length: 30 ft I Joint: N2 J Joint: N3 LC 2: S -SHIFT LC Code Check: 0.386 (bending) Report Based On 97 Sections fa ksi 12.737 at 14.688 ft ksi - 12.737 at 14.688 ft ksi A k 11.703 at O ft IIIIIIl1IItIIllhJIIIIlllIiiiii, 111''1111'lllll�o� hI!III1IIIIIIIIIIIII) -8.037 at 30 ft - 61.166 at 14.688 ft k -ft -.674 at 15 ft in B A /SC ASD 9th Ed. Max Bending Check Location Equation Compact Fy 50 ksi Fa 1.712 ksi Ft 30 ksi Fb 33 ksi Fv 19.142 ksi Cb 1 Code Check 0.386 14.688 ft H2 -1 Cm Lb KL /r Sway Max Shear Check 0.115 Location 0 ft Max Defl Ratio L/534 Out Plane 30 ft 295.376 No L Comp Flange 3.75 ft In Plane 1 30 ft 51.161 No ea m. NJ Shape: W18X35 Material: A572 Gr.50 Length: 30 ft I Joint: N2 J Joint: N3 LC 3: N -SHIFT LC Code Check: 0.389 (bending) Report Based On 97 Sections fa ksi 12.833 at 14.688 ft ksi - 12.833 at 14.688 ft ksi A k 12.673 at 0 ft 1IIIIII III{II111111In l orniIil ...„. e nl !III I m„ m IIIII lH IIIII I ) -8.067 at 30 ft - 61.625 at 14.688 ft k -ft -.68 at 15 ft in AISC ASD 9th Ed. Max Bending Check Location Equation Compact Fy 50 ksi Fa 1.712 ksi Ft 30 ksi Fb 33 ksi Fv 19.142 ksi Cb 1 Code Check 0.389 14.688 ft H1 -1 Max Shear Check 0.125 Location 0 ft Max Defl Ratio L/530 Out Plane Cm Lb 30 ft KUr 295.376 Sway No L Comp Flange 3.75 ft In Plane 1 30 ft 51.161 No JEROD SHEEKS 7717 DETROIT AV SW SEATTLE WA 98106 City qf 7ag='< d ila Department of Community Development Dear Permit Holder: RE: Permit No. M08 -170 12101 TUKWILA INTERNATIONAL BL TUKW In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 08/19/2010. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 08/19/2010, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Bill Rambo Permit Technician File: Permit File No. M08 -170 3„.1,_ Jim Haggerton, Mayor Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 o Phone: 206 - 431 -3670 • Fax: 206- 431 -3665 January 20, 2010 Darla Doll MacDonald - Miller Facility Solutions 7717 Detroit Ave SW Seattle, WA 98106 -1903 RE: Request for Extension #2 Mechanical Permit No. M08 -170 Digital Forest —12101 Tukwila International BI Dear Ms. Doll, This letter is in response to your written request for an extension to Permit Number M08 -170. The Building Official has reviewed your letter and considered your request to extend the above referenced permit. The City of Tukwila Building Division will be extending your permit an additional 180 days from the date of expiration, through August 19, 2010. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, ifer Marshall it Technician File: Permit No. M08 -170 i ty of Tu Department of Community Development W:\Permit Center\Extension Letters\Permits\2008\MO8 -170 Permit Extension #2.doe jem Jim Haggerton, Mayor Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 s Phone: 206 - 431 -3670 o Fax: 206 - 431 -3665 City of Tukwila / Department of Community Development Building Official / Permit Technician RE: Permit No. M08 -170 12101 TUKWILA INTERNATIONAL BL TUK W Permit Technician, Please extend this permit another 180 days. It is set to expire 1/19/2010. 'rhe owner has still not obtained an Electrical permit required for us to finalize our permit. We have our work complete. The owner is aware that this is the issue and is working to resolve it. We are still waiting for them to settle an issue with Puget Sound Energy. If you have any questions please contact me at (206) 768 -4278 or by e-mail Darla.doll @macmiller.com Darla Doll MacDonald Miller , 4Q-ZZ el res D1- 13- 1 -13 -2010 H9-10 RECEIVED JAN .13 2010 PERMIT CENTEF. JEROD SHEEKS 7717 DETROIT AV SW SEATTLE WA 98106 City qf Tukwila Department of Community Development Jack Pace, Director RE: Permit No. M08 -170 12101 TUKWILA INTERNATIONAL BL TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 01/19/2010. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 01/19/2010, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, c Bill Rambo Permit Technician File: Permit File No. M08 -170 Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 06 -03 -2009 JEROD SHEEKS 7717 DETROIT AV SW SEATTLE WA 98106 Department of Community Development Jack Pace, Director RE: Permit No. M08 -170 12101 TUKWILA INTERNATIONAL BL TUKW Dear Permit Holder: Jim Haggerton, Mayor In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 07/24/2009 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician xc: Permit File No. M08 -170 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 January 20, 2009 Darla Doll MacDonald - Miller Facility Solutions 7717 Detroit Ave SW Seattle, WA 98106 -1903 RE: Request for Extension Mechanical Permit No. M08 -170 Digital Forest —12101 Tukwila International BI Dear Ms. This letter is in response to your written request for an extension to Permit Number M08 -170. The Building Official has reviewed your letter and considered your request to extend the above referenced permit. The City of Tukwila Building Division will be extending your permit an additional 180 days from the date of expiration, through July 24, 2009. If you should have any questions, please contact our office at (206) 431 -3670. ifer Marshall it Technician File: Permit No. M08 -170 city of Tukwila Department of Community Development Jack Pace, Director Pea 1.1A P:\Permit Center\Extension Letters \Permits\2008%408 -170 Permit Extension.doc jem Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 • Phone: 206 - 431 -3670 0 Fax: 206 - 431 -3665 MacDonald - Miller FACILITY SOLUTIONS Date: January 16, 2009 To: Bob Benedicto City of Tukwila - Permit Center Fax: (206) 431 -3665 From: Darla Doll • Subject: Permit Extension - M08 -170 Pages: Page, including this cover letter MacDonald - Miller 7717 Detroit Avenue SW Seattle, WA 98106 - 1903 Phone: (206) 768 -3860 Fax: (206) 768 -3861 Please find the attached request to extend mechanical permit M08 -170 another 180 days. Thank you, Darla Doll biAtel /90 ci 0/-24-Z0 �pq oilx •-ti" P Pi , y City of Tukwila Planning & Development Permit Center Subject: Mechanical Permit Extension Thank you, Darla Doll MacDonald- Miller Facility Solutions (206) 768 -4278 Darla.doll@macmiller.com RECEIVED JAN 16 2009 D attuNITY To Bob Benedicto, MacDonald - Miller Facility Solutions is requesting a 180 -day extension of Permit # M08 -170 which will expire on 1 -25 -09 for Digital Forest mechanical work. The reason is that we are currently waiting for the owner to finalize the fire alarm scope and it's interaction with the emergency shutdown of the unit. Please let me know the next expiration datc so that I can note it in my records. Feel fire:: to call or e-mail me with any questions or concerns. 12 -03 -2008 JEROD SHEEKS 7717 DETROIT AV SW SEATTLE WA 98106 RE: Permit No. M08 -170 12101 TUKWILA INTERNATIONAL BL TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a fmal inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or fmal inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in wrttinm and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 01/25/2009 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, 4 (411 fer Marshall, P . 't Technician xc: Permit File No. M08 -170 r A C ity ofTu . la Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 A Tukwila, Washington 98188 ® Phone: 206 - 431 -3670 0 Fax: 206 - 431 -3665 DEPARTMENTS: �G o(t Building Division Public Works Comments: APPROVALS OR CORRECTIONS: Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 PERMIT CORD COPY r PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: MO's -170 • DATE: 06 -20 -08 PROJECT NAME: DIGITAL FOREST SITE ADDRESS: 12101 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued F Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete N Incomplete Permit Center Use Only : • • INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUT NG: Please Route Structural Review Required REVIEWER'S INITIALS: Approved I Approved with Conditions n Planning Division In Permit Coordinator DUE DATE: 06-24-08 Not Applicable n No further Review Required DATE: Not Approved (attach comments) DATE: n DUE DATE: 07-22 -08 Permit Center Use Only • ' ' CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License MACDOFS980RU Licensee Name MACDONALD/MILLER FAC SOL INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602254260 Ind. Ins. Account Id CHIEF OPERATING OFFICER Business Type CORPORATION Address 1 PO BOX 47983 Address 2 City SEATTLE County KING State WA Zip 98106 Phone 2067684180 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 12/31/2002 Expiration Date 12/31/2008 Suspend Date Separation Date Parent Company Previous License DIVCOI *988RC Next License Associated License Business Owner Information Name Role Effective Date Expiration Date TURLEY, DOUGLAS CHIEF EXECUTIVE OFFICER 02/13/2008 TURLEY, DOUGLAS CHIEF OPERATING OFFICER 02/13/2008 SIGMUND, FREDRIC PRESIDENT 12/31/2002 HACK, RICHARD SECRETARY 02/13/2008 KOPET, TYLER TREASURER 12/31/2002 LOVELY, STEVE Look Up a Contractor, Electoan or Plumber License Detail Washington State Depailalent of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. to Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= MACDOFS980RU 07/07/2008 DAMPER LEGEND SYMBOL DESCRIPTION- POWERED SYMBOL DESCRIPTION -NON POWERED 1 1/2 HOUR VERTICAL COMBINATION FIRE /SMOKE 4 FD HFD FD HFD ® ED 1 1/2 HOUR CURTAIN STYLE VERTICAL FIRE DAMPER GREENHECK DFD 150 OR EQUAL 1 1/2 HOUR CURTAIN STYLE HORIZONTAL FIRE DAMPER FSD GREENHECK FSD 212 (2000 FPM) OR EQUAL GREENHECK FSD 312 (3000 FPM) OR EQUAL 1 1/2 HOUR HORIZONTAL COMBINATION FIRE /SMOKE OR EQUAL GREENHECK DFD 150 (HORIZONTAL MOUNT) OR EQUAL 3 HOUR CURTAIN STYLE VERTICAL FIRE DAMPER HFSD ® GREENHECK FSD 212 (2000 FPM) GREENHECK FSD 312 (3000 FPM) OR EQUAL 1 1/2 HOUR TUNNEL CORRIDOR COMBINATION FIRE /SMOKE GREENHECK DFD 350 OR EQUAL 3 HOUR CURTAIN STYLE HORIZONTAL FIRE DAMPER TFSD ® GREENHECK CFSD 212 -1 OR EQUAL • 3 HOUR VERTICAL COMBINATION FIRE /SMOKE GREENHECK DFD 350 (HORIZONTAL MOUNT) OR EQUAL CEILING RADIATION DAMPER FSD GREENHECK FSD 231 OR EQUAL 3 HOUR HORIZONTAL COMBINATION FIRE /SMOKE GREENHECK CRD -2 OR EQUAL BACKDRAFT DAMPER HFSD • GREENHECK FSD 231 OR EQUAL SMOKE DAMPER BDD BAR ® 14/12 SL GREENHECK WD 330 (VERT) OR WD -100 (HORIZONTAL) OR EQUAL BAROMETRIC RELIEF DAMPER (.05 OPNG PRESSURE SHOWN) SD © GREENHECK SMD 202 OR EQUAL MOTORIZED CONTROL DAMPER ' RUSKIN CBD2 NO SUBSTITUTE ALLOWED VOLUME DAMPER SHOP FABRICATED, W/ LOCKING QUADRANT MD © GREENHECK VCD -23 OR EQUAL SMOKE CONTROL MOTORIZED DAMPER GREENHECK SMD 301 OR EQUAL BARE FLAT OVAL SHEETMETAL SCD ® INTERLOCK WITH FIRE ALARM BY ELECTRICAL CONTRACTOR ACCESS DOOR AD > 18"x 18" MINIMUM THROUGH BUILDING CONSTRUCTION BY GENERAL CONTRACTOR GENERAL NOTES: COMBINATION FIRE /SMOKE DAMPER REQUIREMENTS (UNLESS OTHERWISE NOTED): - CLASS II - 165° FUSIBLE LINK - FAIL - CLOSE, 120V ACTUATOR - ACTUATOR BY MECHANICAL CONTRACTOR, WIRING BY ELECTRICAL CONTRACTOR - INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR FIRE DAMPER REQUIREMENTS: - BLADES OUT OF AIRSTREAM ON MEDIUM PRESSURE DUCTS -165 F FUSIBLE LINK - CLASS II o- , " f m ,= DUCT LEGEND DESCRIPTION SYMBOL DESCRIPTION SYMBOL BARE SHEETMETAL EXH FAN ROUND SHEETMETAL WRAPPED W/ INSULATION (2 ") EER/ IPLV 14/12 120W NOTES CFM SOUNDLINE SHEETMETAL (1" LINING) QTY CLEANROOM QUALITY DUCTWORK QTY 14/12 SL 14/12 C HP VOLT /PH SHEETMETAL WRAPPED W/ INSULATION (2 ") AC -1 BARE FLAT OVAL SHEETMETAL 75 14/12 W 14/12$ 2 BARE ROUND SHEETMETAL 2 FLAT OVAL FLAT SHEETMETAL W/ INSULATION (2 ") 6 120 14/ 12e-W 460/3 EXPOSED QUALITY SHEETMETAL 1 DUCTBOARD (1" FIBERGLASS) AAON RN -070 14/1 Q 14/12 DB 2 2 EXAMPLE OF NEW 1000 EXAMPLE OF NOT IN CONTRACT (NIC) - .__ 14/12 i 14/12 3/4 EXAMPLE OF DEMO x x FLEX DUCT 7000 x x x x x xxxxxxx EXAMPLE OF EXISTING 70 FLEX CONNECTOR 2 14/12 3 f 1000 2 PACKAGED ELECTRIC AIR CONDITIONING SCHEDULE UNIT NO. MFG & MODEL NO. NOM TONS SUPPLY FAN OA CFM EXH FAN COND FAN EER/ IPLV ELECTRICAL WT LBS NOTES CFM ESP QTY HP QTY HP QTY HP VOLT /PH MCA AC -1 TRANE SXHFC75 75 2 2 20 6 1 460/3 11000 1 AC -2 AAON RN -070 70 25000 2 2 15 1000 2 3 6 3/4 9.4/10.1 460/3 157 7000 3 AC -3 AAON RN -070 70 25000 2 2 15 1000 2 3 6 3/4 9.4/10.1 460/3 157 7000 3 AC-4 AAON RN-070 70 25000 2.0 2 15 1000 2 3 6 3/4 9.4110.1 460/3 157 7000 2,4,5 AC -5 AAON RN -070 70 25000 2.0 2 15 1000 2 3 6 3/4 9.4/10.1 460/3 157 7000 3 CO 0 0 N 0 N (1) C T rr) Ln NOTES: 1. EXISTING ROOFTOP AIR CONDITIONING UNIT TO REMAIN. 2. NEW ROOFTOP PACKAGED AIR CONDITIONING UNIT WITH THE FOLLOWING FEATURES /ACCESSORIES: R -22 REFRIGERANT (4) SCROLL COMPRESSORS 100% ECONOMIZER WITH DDC ACTUATOR ON OSA DAMPER DUAL SUPPLY FANS WITH VFDS DUAL POWER EXHAUST FANS 4" 65% FILTERS HOT GAS BYPASS ON LEAD COMPRESSOR RETURN AIR SMOKE DETECTOR - CONNECTION TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR 3. FUTURE ROOFTOP PACKAED AIR CONDITIONING UNIT. 4. DISCONNECT BY ELECTRICAL CONTRACTOR. 5. REVERSE MOUNTING POSITION OF RETURN DAMPER ACTUATOR IN THE FIELD SO THAT IT FAILS CLOSED. ABBV FULL NAME A COMPRESSED AIR LINE AC AIR CONDITIONING UNIT AFF ABOVE FINISHED FLOOR AL ALUMINUM BDD BACKDRAFT DAMPER BOB BOTTOM OF BEAM BOD BOTTOM OF DUCT BOTT BOTTOM BTU BRITISH THERMAL UNITS BTUH BRITISH THERMAL UNITS PER HOUR BWG BOTTOM WALL GRILLE BWR BOTTOM WALL REGISTER C CONDENSATE CAP CAPACITY CC CONTROLS CONTRACTOR CFM CUBIC FEET PER MINUTE CHWR CHILLED WATER RETURN CHWS CHILLED WATER SUPPLY COMB COMBUSTION CONN CONNECT CWR CONDENSER WATER RETURN CWS CONDENSER WATER SUPPLY DB DUCT BOARD DIFF DIFFUSER DMPR DAMPER DN DOWN EC ELECTRICAL CONTRACTOR EGC EGGCRATE EER ENERGY EFFICIENCY RATIO ELEV ELEVATION EMS ENERGY MANAGEMENT SYSTEM NAME TITLE TM0.01 SCHEDULES - HVAC TM2.04 4TH FLOOR PLAN - HVAC TM2.05 ROOF PLAN - HVAC TM6.01 DETAILS - HVAC HVAC ABBREVIATIONS ABBV FULL NAME ESP EXTERNAL STATIC PRESSURE EXH EXHAUST EXTR EXTRACTOR FAC FIRE ALARM CONTRACTOR FD FIRE DAMPER FLA FULL LOAD AMPS FOB FLAT ON BOTTOM FOT FLAT ON TOP FSD FIRE SMOKE DAMPER G GAS LINE GALV GALVANIZED GC GENERAL CONTRACTOR GPM GALLONS PER MINUTE GR GRILLE GWB GYPSUM WALL BOARD HG HOT GAS LINE HP HORSE POWER HWR HOT WATER RETURN HWS HOT WATER SUPPLY ID INSIDE DIMENSION INT INTERLOCK LIQ LIQUID LINE M -M MACDONALD- MILLER MBH ONE THOUSAND BTUH MC MECHANICAL CONTRACTOR MCA MINIMUM CIRCUIT AMPACITY MD MOTORIZED DAMPER MIN MINIMUM MT MOUNT MUA MAKE -UP AIR NOM NOMINAL ABBV OSA OBD OD RA REG REQ'D RIO SA SCD SD SL SM SP SS SSSC STL SUC SUSP T'STAT TC TOD TOS TV TWG TWR TYP UNO VD VFD FULL NAME OUTSIDE AIR OPPOSED BLADE DAMPER OUTSIDE DIMENSION RETURN AIR REGISTER (GRILLE WITH DAMPER) REQUIRED ROUGH IN ONLY SUPPLY AIR SMOKE CONTROL DAMPER SMOKE DAMPER SOUND LINING SHEET METAL STATIC PRESSURE START /STOP SOLID STATE SPEED CONTROLLER STEEL SUCTION LINE SUSPENDED THERMOSTAT TEMPERATURE CONTROL TOP OF DUCT TOP OF STEEL TURN VANES TOP WALL GRILLE TOP WALL REGISTER TYPICAL i City of Tukwila UNLESS NOTED OTHERWISE BI)L.DING DIVISI VOLUME DAMPER VARIABLE FREQUENCY DRIVE VOLTAGE PHASE & DUCT DIAMETER DRAWING SHEET INDEX NAME TITLE e are, e�1�►■ rinr ro./{ , approval Is subject to errors and onqssions. Approval of construction documents does not authorize th violation of any adopted axle or ordinance. Reclipt a' Epp, over Field Copy and conditions is actlo wletdged: By Date: of ME wEIa SEPARATE PER ¢ REQUIRED FO Mechanical Electrical Plumbing Gas Piping CONTACT LIST ELI . DING DIVISION TITLE NAME COMPANY PHONE NUMBER E -MAIL PROJECT ENGINEER ACCOUNT EXECUTIVE SHEET METAL FOREMAN JARED SHEEKS STEVE FLINK LARRY HARBISON MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER 206 - 768 -3806 253 -680 -3172 206 - 768 -4294 jared.sheeks(imacmiller.com steve.flink(a),macmiller.com Iarry.harbisonArnacmiller.com SCOPE OF WORK PHASE 1: PROVIDE AND INSTALL (1) ROOFTOP PACKAGED AIR CONDITIONING UNIT TO SERVE DATA CENTER. UNIT TO INCLUDE 100 %° OSA ECONOMIZER CAPABILITY. INSTALL (1) STRUCTURAL STEEL PLATFORM FOR EACH UNIT. INSTALL RETURN AIR DUCTWORK CONNECTING AIR CONDITIONERS TO COMPUTER ROOMS. INSTALL SUPPLY DUCTWORK CONNECTING NC UNITS TO SUPPLY PLENUM. INSTALL (1) TEMPERATURE SENSOR IN SUPPLY DUCTWORK. DUCTWORK AND EQUIPMENT ADDITIONS INSIDE THE DATA CENTERS WILL BE PERMITTED SEPARATELY. REVISIONS shall be made to the scope vithout prior approval of Tukwila Building Division. TE: Revisions will require a new plan submittal and may include additional plan review fees. 1. THE HVAC SYSTEM FOR THIS PROJECT IS BASED ON THE FOLLOWING CRITERIA: ROOF "U" VALUE (BTUH /S.F. °F) = N/A WALL "U" VALUE (BTUH /S.F. °F) = N/A FLOOR "U" VALUE (BTUH /S.F. °F) = N/A GLASS "U" VALUE (BTUH /S.F. °F) = N/A GLASS SHADE COEFF. = N/A LIGHTING (WATTS /S.F.) = N/A MISC. EQUIP. (WATTS /S.F.) = N/A PEOPLE DENSITY (S.F./PERSON) = N/A COOLING INDOOR DESIGN TEMP ( °F) = N/A COOLING OUTDOOR DESIGN TEMP ( °F) = N/A HEATING INDOOR DESIGN TEMP ( °F) = N/A HEATING OUTDOOR DESIGN TEMP ( °F) = N/A HVAC GENERAL NOTES REVIEWED FOR` CODE COMPLIANCE APPROVED JUL 01 008 Ci Of 4 ila B ILDIN D ION 2. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 3. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2006 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 4. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2006 IMC AND WITH CURRENT SMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28" DIA AND LARGER WHICH ARE SUSPENDED MORE THAN 12" BELOW STRUCTURAL SYSTEM. 5. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 6. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2006 WSEC. - DUCT WRAP, WHERE INDICATED, SHALL BE 1 1/2" 0.75 LB /CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER (R-4.2 MIN.). - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB /CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM (R-4.2 MIN.). - DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED El 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT (R-4.3 MIN.). 7. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" FIBERGLASS INSULATION, AND NON - PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 8' IN LENGTH UNLESS NOTED OTHERWISE. 8. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1621 OF THE 2006 IBC. 9. PROVIDE FIRE DAMPERS, SMOKE DAMPERS AND FIRE/SMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.5 OF THE 2006 IBC. PROVIDE CEILING FIRE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.6.2 OF THE 2006 IBC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRE /SMOKE DAMPERS IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, THE TERMS OF THEIR LISTING, AND THE REQUIREMENTS OF THE CODE. 10.PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 11.PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING, COOLING, OR VENTILATION EQUIPMENT MOVING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH SECTION 606 OF THE 2006 IMC. POWER AND INTERLOCK WIi3ING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. 12.HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. 13. HEAT TRACING OF PIPING, WHERE INDICATED, SHALL BE PROVIDED AND INSTALLED BY THE HVAC CONTRACTOR. THE HVAC CONTRACTOR IS TO COORDINATE THE HEAT TRACE POWER WIRING WITH THE ELECTRICAL CONTRACTOR. 14.MOTOR STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. 15. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 16. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 17. COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON ATE ENERGY CODE (WSEC) SECTION 1416 AND WITH LEED NC -2.1 FUNDAMENTAL BUILDING SYSTEMS COMMISSIONING AND ADDITIONAL COMMISSIONING. 18.A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPAREL` AND FILED: WITH THE OWNER. 12101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA VICINITY MAP NO SCALE 19. FOR ALL "SEALED AIR TIGHT" SHAFTS OR ROOMS, THE FOLLOWING MUST OCCUR: - ALL VERTICAL JOINTS INSIDE THE SHAFT SHOULD BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT, INCLUDING THE SHAFT CORNERS (BY GC). - TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC). - ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT SHOULD BE CAULKED. FILLING WITH ROCK WOOL OR FIRESAFING ( "MONOCOAr) IS NOT ACCEPTABLE (BY GC). - ANY PENETRATIONS OF THE SHAFT CONSTRUCTION (DUCTWORK, CONDUIT, PIPING) SHOULD BE SEALED WITH FIRE CAULKING ON BOTH SIDES OF THE PENETRATION. - USE SECTION 909.5 OF THE 2006 IBC FOR MAXIMUM ALLOWABLE LEAKAGE AREA, FOLLOWING THE GUIDELINES FOR SMOKE BARRIER CONSTRUCTION. - ALL DOORS MUST BE PROVIDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF ROOM /SHAFT PRESSURE. 20.DAMPERS USED FOR OUTDOOR AIR INTAKE, EXHAUST, OR RELIEF SHALL HAVE THE FOLLOWING MAXIMUM LEAKAGE RATES AT 1" W.G. (PER AMCA STANDARD 500): MOTORIZED DAMPERS: 10 CFM /S.F. GRAVITY DAMPERS: 20 CFM /S.F. (40 CFM /S.F. FOR DAMPERS SMALLER THAN 24 INCHES IN EITHER DIMENSION). 21.OUTSIDE AIR INTAKE, EXHAUST, AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE MOTORIZED (FAIL CLOSED) PER WSEC 1412.4.1, EXCEPT AS ALLOWED BY WSEC. 22.RETURN AIR SHAFTS TO BE CONSTRUCTED BY THE G.C. TO WITHSTAND A MINIMUM 20 PSF DIFFERENTIAL PRESSURE ACROSS THE WALL. DIFFERENTIAL PRESSURE IS BASED UPON THE MAXIMUM STATIC PRESSURE CAPABILITY OF FAN SYSTEMS SUBJECT TO AUTOMATIC DAMPER CLOSURE. 23.PRESSURIZATION SHAFTS SHALL BE CONSTRUCTED BY THE G.C. AS FOLLOWS: - SHAFTS SERVED BY PRESSURIZATION FANS RATED UP TO 1" STATIC PRESSURE TO BE CONSTRUCTED TO WITHSTAND 10 PSF DIFFERENTIAL PRESSURE. - SHAFTS SERVED BY PRESSURIZATION FANS RATED BETWEEN 1 -2.5" STATIC PRESSURE TO BE CONSTRUCTED TO WITHSTAND 20 PSF DIFFERENTIAL PRESSURE. - FOR SHAFTS SERVED BY PRESSURIZATION FANS RATED ABOVE 2.5" STATIC PRESSURE, CONTACT MECHANICAL ENGINEER. LEGAL DESCRIPTION APN # 0923049309 LEGAL DESCRIPTION: BEGIN NW CORNER OF NE 1/4 OF SE 1/4 TH S 89 -16 -35 E "100 FT TH S 24 -13 -53 E 567.42 FT TO POINT OF BEGINNING TH N 66 -35 -01 E 120.47 FT TH N 20 -23 -23 W 27.58 FT TH N 65 -32 -34 E 165 FT TO POINT ON WLY R/W LINE OF PRIMARY STATE HIGHWAY NO 1 (SR 99) SOUTH 118TH ST TO JCT SSH NO 1 -K APPROVED JULY 23, 1957 TH FOLLOWING SAID WLY R/W LINE S 24 -27 -26 E 110.84 FT TH FOLLOWING SAID WLY RPM LINE N 65 -32 -34 E 10 FT TH FOLLOWING SAID WLY R/W LINE S 24 -27 -26 E 200 FT TH FOLLOWING SAID WLY R/W LINE N 65 -32 -34 E 20 FT TH FOLLOWING SAID WLY R/W LINE S 24 -27 -26 E 126 FT TH FOLLOWING SAID WLY R/W LINE ALONG ARC OF 2805 FOOT RADIUS NON TANGENT CURVE TO RIGHT CENTER BEARING S 65 -32-34 W THRU C/A OF 0 -12 -18 DISTANCE OF 10.03 FT TH S 65 -30 -25 W 199.33 FT TH N 22 -47 -01 W 21.44 FT TH S 63 -32-48 W 62.13 FT TH S 65 -46 -07 W 58.17 FT TH N 24 -13 -53 W 402.19 FT TO POINT OF BEGINNING LOT C OF CITY OF TUKWILA BOUNDARY LINE ADJUSTMENT NO L98 -0033 RECORDING NO 9810059013 SITE MAP NO SCALE MacDonald - Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206 - 763 -9400 Fax: 206 - 767 -6773 www.macmiller.com WA Lic No: MACDOFS980RU I EXPIRES: 07 -06 -08 RECEIVED CITY OF TUKWILA JUN 2 0 2008 REVISIONS PERMIT CENTER DATE DIGITAL FOREST DATA CENTER EXPANSION AC -4 ADDITION 12101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA SCHEDULES & NOTES - HVAC ENGINEER: J SHEEKS CHECKED BY: B GEZON LAST REVISED: CAD: , , P MILLER 06 -20 -08 OTTED: ?0 -08 DRAWING NUMBER: C - 1 490- 7386342 -00 -00 ISSUED FOR PERMIT SHEET NUMBER: TMOD1 0 0 S o I- I- N d M co ( I- I to 0 0 z w 0 0 to r7 I- zz 0 1 I- N LL1 0 L- 0 0 N d c0 CO T 1 cc L ewra:Ry R4. ay., RK,11 FUTURE ) — REVIEWED r011 CODE COMPLIANCE APPROVED JUL 0 1 2008 CO- j 0 T / 4 ) IL I- 0 a I- 0 0 0 ... ,....,,,,..„,,,..,T,,,,..._...,„..,.......„,___,.,_",„,,.,,...=.„,...,.,,, f 42/50 SL/2" RETURN DROP 4TH FLOOR PLAN - HVAC VACANT 4NE14 — FUTURE N ( RETURN DROP CO-LOCATION F- 42‘f".;;. t 7 City Of Tukwila _13MINEMEDIN t 0 8 of " c) MacDonald-Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206-763-9400 Fax: 206-767-6773 www.macmiller.com WA Lic No: MACDOFS980RU REVISIONS: DATE DIGITAL FOREST DATA CENTER EXPANSION AC-4 ADDITION 12101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 4TH FLOOR PLAN - HVAC ENGINEER: LAST REVISED: J SHEEKS 06-20-08 CHECKED BY: DATE PLOTTED: B GEZON 60-20-08 CAD: ISSUE DATE: P MILLER DRAWING NUMBER: C - 1 49 0 - 738 6 3 42 - 0 0 ISSUED FOR PERMIT SHEET NUMBER: TM2.04 E ) RECEIVED CITY OF TUKWILA JUN 2 0 2008 PERMIT CENTER (EXIS ING) (EXISTING) NPCW ON THE R0 PROVID D W/ \ HEAT TAPE, INSULATION ' WEATHER —PROOr JACKET 3/4"NPCW FROM BELOW ROOF (EXISTING) EXISTING) — — ''''' -- 17 ---- 7 -7 77777_7772.1 7 11:117777_7777„ 0 tyv CONDENSATE LINE \ TO ROOF DRAIN 1)/2" PVC EXISTING SCREENWALL EXIS G 3/4"NPCW, CONNECTED HUMI IFIER (TYR) 26"0 DI\ 24"0 DN 48"95 Dlk EX ELECTRICAL \\ PANELS I \ I \1. 1Y2 PVC" 11\SLOPE TO DRAIN \ \ I z 0 (EXISTING) INSTALL TRAP & \ PIPE PRIMARY CNDS TO ROOF DRAIN 1" PVC (BOTH SIDES) \ EF— (EXISTING) I I I I I I 1 1 AC-3 N ftft (EXISTING) 0) z 6'-8" ' ' 7 . . L T ti I 474 I AC-4 — 11 — fw L 8'-4" ri lY2 SLOPE TO RAIN T (f) z ROOF PLAN - HVAC SCALE: Ya" = N ROOFTOP STEEL SUPPORT ir STRUCTURE (SEE STRUCT DRAWINGS) 1 1 '-8" / • go a., I . 0 \ N 6'-8" I \ 4. — 8 — — G-- I 8"0 DU ROOF TO THRU O TO RO F CAP N. EF-2) City Of TukwilR BUILDING QVISIL, REVIEWED FOR CODE COMPLIANCE APPROVED JUL 0 1 2000 8 RECEIVED CITY OF TUKWILA JUN 2 0 2008 PERMIT CENTER MacDonald-Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206-763-9400 Fax: 206-767-6773 wwvv.macmiller.com WA Lic No: MACDOFS980RU REVISIONS: DATE DIGITAL FOREST DATA CENTER EXPANSION AC-4 ADDITION 12101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA ROOF PLAN - HVAC ENGINEER: J SHEIKS CHECKED BY: B GEZON CAD: P MILLER LAST REVISED: 06-20-08 DATE PLOTTED: 06-20-08 ISSUE DATE: DRAWING NUMBER: C— 1490-7386342-00 ISSUED FOR PERMIT SHEET NUMBER: TM2.05 J DUCT DROP (SUPPLY OR RETURN) STORM COLLAR /FLASHING 2x2 NAILER 2x10 CURB FRAMING 16 GA STEEL CURB ROOFING (BY OTHERS) v) CANT STRIP BUILT -UP FOAM INSULATION (BY OTHERS) CORRUGATED STEEL ROOF DECK STEEL ANGLE FOR ROOF DECK SUPPORT 3 ROOF CURB DETAIL AT SUPPLY & RETURN DUCTS KAF n1 1" = 1' to 0 \ \ HEIGHT TO TOP OF STEEL RAILS o W18x71 STEEL RAILS (PER STRUCTURAL DRAWINGS) CHANNEL OR TUBE STEEL PERIMETER SUPPORT W14x43 CROSS MEMBERS (PER STRUCTURAL DRAWINGS) l 4 NEW ROOF CURB FOR SUPPLY AIR DROP (CURB BY M.C.; CUTTING, PATCHING, AND ROOFING BY OTHERS) J L 54" X46" SUPPLY AIR DUCT W/ 2" SOUND LINER li FLEX CONNECTOR QUICK CHANGE W18x71 STEEL RAILS ---\ (PER STRUCTURAL DRAWINGS) ROOF TOP AIR CONDITIONER ROOFTOP UNIT ELEVATION 1/2" = 1' STRUCTURAL STEEL PLATFORM 1/2" = 1' \ _ \ 54" X46" RETURN AIR DUCT W/ 2" SOUND LINER L \ REVIEWED FOR CODE COMPLIANCE APPROVED JUL 01 2008 City Of Tukwila BUILDIN DM ION ROOF DECK OSA INTAKE HOOD CHANGE RETURN DAMPER ACTUATOR POSITION IN THE FIELD SO THAT IT FAILS CLOSED % ^1 W14x43 STRUCTURAL STEEL CROSS MEMBERS (PER STRUCTURAL DRAWINGS) 6" PIPE (PER STRUCTURAL DRAWINGS) 6" SCHEDULE 80 PIPE (PER STRUCTURAL DRAWINGS) W14x43 STRUCTURAL STEEL CROSS MEMBERS (PER STRUCTURAL DRAWINGS) tit 94k17 RECEIVED CITY OF TUKWILA JUN 2 0 2008 PERMIT CENTER MacDonald- Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206 - 763 -9400 Fax: 206- 767 -6773 www.macmiller.com WA Lic No: MACDOFS980RU REVISIONS: DATE DIGITAL FOREST DATA CENTER EXPANSION AC -4 ADDITION' 12101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA DETAILS HVAC ENGINEER: LAST REVISED: J SHEEKS 06 -20 -08 CHECKED BY: DATE PLOTTED: B GEZON 06 -20 -08 CAD: ISSUE DATE: P MILLER DRAWING NUMBER: C 1 490 - 7386342 -00 ISSUED FOR PERMIT SHEET NUMBER: TM6O1 HEIGHT TO TOP OF UNIT Friday, June 20 HEIGHT TO TOP OF FAN SHROUD 09:31:13 AM, r W14x22 STRUCTURAL STEEL CROSS MEMBERS (PER STRUCTURAL DRAWINGS) --I I— T W14x43 STEEL CROSS MEMBERS 16' -10" W14x22 STEEL CROSS MEMBERS (PER STRUCTURAL DRAWINGS) - T L �1 „'b —.8 I-- H I I I — 1 H —(PER STRUCTURAL DRAWINGS) 1 L 7' -1" I I / 3' -1" -1 r . / 27' -0 J DUCT DROP (SUPPLY OR RETURN) STORM COLLAR /FLASHING 2x2 NAILER 2x10 CURB FRAMING 16 GA STEEL CURB ROOFING (BY OTHERS) v) CANT STRIP BUILT -UP FOAM INSULATION (BY OTHERS) CORRUGATED STEEL ROOF DECK STEEL ANGLE FOR ROOF DECK SUPPORT 3 ROOF CURB DETAIL AT SUPPLY & RETURN DUCTS KAF n1 1" = 1' to 0 \ \ HEIGHT TO TOP OF STEEL RAILS o W18x71 STEEL RAILS (PER STRUCTURAL DRAWINGS) CHANNEL OR TUBE STEEL PERIMETER SUPPORT W14x43 CROSS MEMBERS (PER STRUCTURAL DRAWINGS) l 4 NEW ROOF CURB FOR SUPPLY AIR DROP (CURB BY M.C.; CUTTING, PATCHING, AND ROOFING BY OTHERS) J L 54" X46" SUPPLY AIR DUCT W/ 2" SOUND LINER li FLEX CONNECTOR QUICK CHANGE W18x71 STEEL RAILS ---\ (PER STRUCTURAL DRAWINGS) ROOF TOP AIR CONDITIONER ROOFTOP UNIT ELEVATION 1/2" = 1' STRUCTURAL STEEL PLATFORM 1/2" = 1' \ _ \ 54" X46" RETURN AIR DUCT W/ 2" SOUND LINER L \ REVIEWED FOR CODE COMPLIANCE APPROVED JUL 01 2008 City Of Tukwila BUILDIN DM ION ROOF DECK OSA INTAKE HOOD CHANGE RETURN DAMPER ACTUATOR POSITION IN THE FIELD SO THAT IT FAILS CLOSED % ^1 W14x43 STRUCTURAL STEEL CROSS MEMBERS (PER STRUCTURAL DRAWINGS) 6" PIPE (PER STRUCTURAL DRAWINGS) 6" SCHEDULE 80 PIPE (PER STRUCTURAL DRAWINGS) W14x43 STRUCTURAL STEEL CROSS MEMBERS (PER STRUCTURAL DRAWINGS) tit 94k17 RECEIVED CITY OF TUKWILA JUN 2 0 2008 PERMIT CENTER MacDonald- Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206 - 763 -9400 Fax: 206- 767 -6773 www.macmiller.com WA Lic No: MACDOFS980RU REVISIONS: DATE DIGITAL FOREST DATA CENTER EXPANSION AC -4 ADDITION' 12101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA DETAILS HVAC ENGINEER: LAST REVISED: J SHEEKS 06 -20 -08 CHECKED BY: DATE PLOTTED: B GEZON 06 -20 -08 CAD: ISSUE DATE: P MILLER DRAWING NUMBER: C 1 490 - 7386342 -00 ISSUED FOR PERMIT SHEET NUMBER: TM6O1 HEIGHT TO TOP OF UNIT Friday, June 20 HEIGHT TO TOP OF FAN SHROUD 09:31:13 AM,