Loading...
HomeMy WebLinkAboutPermit PG08-055 - WESTFIELD SOUTHCENTER MALL - WHITE HOUSEWHITE HOUSE 656 SOUTHCENTER MALL PGO8-055 Parcel No.: Address: Suite No: Citytf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206= 431 =3670 Fax: 206 -431 -3665 Web site: http : / /www.ci.tukwila:wa,us PLUMBING /GAS PIPING PERMIT 6364200010 656 SOUTHCENTER MALL TUKW Permit Number: Issue Date: Permit Expires On: PG08 -055 05/05/2008 11/01/2008 Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: WHITE HOUSE 656 SOUTHCENTER MALL , TUKVVILA WA WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA KATHY KRUSE 10877 WATSON RD , ST LOUIS MO MANZCO PLUMBING PC) BOX 822964 , VANCOUVER WA Contractor License No: MANZCP *926B8 Phone: Phone: 314 - 821 -1100 Phone: 360 772 -8149 Expiration Date: 01/28/2010 DESCRIPTION OF WORK: CONSTRUCTION OF TWO TOILET ROOMS 9INCLUDING DRINKING FOUNTAINS) AND INSTALLATION OF MOP SINK Value of Plumbing /Gas Piping: Fees Collected: $27,000.00 $271.00 Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND OUANTITY Plumbing - -- -- Bathtub or combination bath/shower 0 Bidet 0 Clothes washer, domestic 0 Dental unit, cuspidor 0 Dishwasher, domestic, with independent drain 0 Drinking fountain or water cooler (per head) - - -- - 2 Food -waste grinder, commercial 0 Floor drain 2 Shower, single head trap 0 Lavatory - 2 Wash fountain 0 Receptor, indirect waste 0 Sinks 1 Urinals 0 Water Closet 2 Plumbing (cont,) Building sewer and each trailer park sewer 0 Rain water system - per drain (inside bldg) 0 Water heater and /or vent 1 Industrial waste treatment interceptor, including its trap and vent, except for kitchen type grease interceptors 0 Repair or alteration of water piping and/or water treatment equipment 0 Repair or alteration of drainage or vent piping - 0 Medical gas piping system serving (1 -5) inlets /outlets for a specific gas 1 Medical gas piping (6 +) inlets /outlets 1 Gas Piping Gas piping outlets (0 -5) 0 Gas piping outlets (6 +) 0 * *continued on next page ** doc: UPC -10/06 PG08 -055 Printed: 05 -05 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 -431 -3665 Web site: http : / /www.ci.tukwila.waAis Permit Number: Issue Date: Permit Expires On: PG08 -055 05/05/2008 11/01/2008 Permit Center Authorized Signature: I hereby certify that I have governing thi, • rk will be e•d and e omplied The granting of thi . errnit does construction • e p a ormance o Signature: Print Name: Date: 051 051A ed this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. �t presume to give authority to violate or cancel the provisions of any other state or local laws regulating work. I am authorized to "sign and obtain this plumbing /gas piping permit. f `A.0 h 2�'t �✓ -� Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -10/06 PG08 -055 Printed: 05 -05 -2008 Parcel No.: 6364200010 Address: Suite No Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.ci.tukwila.wa.us 656 SOUTHCENTER MALL TUKW WHITE HOUSE PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG08 -055 ISSUED 02/22/2008 05/05/2008 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be mamtamed at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plambing Inspector. It shall be the duty of the holder of the permit to make sure that the work: Will stand the test prescribed before giving notification that the work is ready for inspections 7: No water, soil, or Waste pipe shall be installed or permitted outside of a building or m an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3s 8: Plastic and copper pi.ping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated Walls or partitions shall be protected in accordance with the requirements of the building code. 11: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. **continued on next page ** doc: Cond -10/06 PG08 -055 Printed: 05 -05 -2008 I hereby certify that I have this work will be complied The granting of this per 't construction or perfo Signature: • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila:wa.us read these conditions and will comply with them as outlined. All provisions of law and with; whether specified herein or not. does not presume to give authority to violate or cancel the provision of any other work ance of work. Print Name: _N ■ Date: 5 S O ordinances governing or local laws regulating doc: Cond -10/06 PG08 -055 Printed: 05 -05 -2008 CITY OF TUKWILA teithibiinity Development Public Works Department 6:100 '8Oulhcenter Blvd., 046'100 ,Tukwila, WA .981E8 Applications and plans must be ,complete in order to be accepted for plan review. Applications will fail beaccepted through the mail or by fax. **Please Print** Site Address: Tenant Nanne:1,el4 1=tte--7 Cl'Ai-b-legt- -- .Property Owners Name: Li r v_,/...tp Kingto A's Tax No.— (,,_.3 ta_ 4 7c L.) C Suite Number: Floor_kr New Tenant: 12-_ Ye S .. No Mailing AddreSS:63,15-5_ tt , & q 6F--) City State Zip f';e4' • 7Erigo N - 341.4 . . . ';04.%;.st, :44,C424904M:P .42" ,.,ft Narne: _ Day Telephone: 4=e,e.-Li= Hoc) , Mailing Address: OED-1 1 3T. Le5Lt (s, 6.23 l 'City , State Zip &MA Addr-gg1 g)20._Lt 6te:5-1:ccet-p, _ Fax Number:_6 14 = 4 ic&8__ _ 540: LE 11: itPntrWattnfoxmptilifia0114:04a.niakiii4if4i;1•, ti0j) Company Name: -rtr Mailing Address: City State Ctintaet Person: Day Telephone:___ AddreSs:__ Fax Number: Expiration Date: Caitfaetor 'Registration Number Zip Company Name: - Mailing Address:A(06:7 4=t-5-1- T. Lob Contact Person&HL"( taLibt... E-Mail Ad dfe3S'.2111') ic5 61z City State Zip Day Telephone: 3 t_ 4- -- FaX Number__,..5_i _4 7_ A- _Ito_ ENOINEER OF ktetiit-Apitit be wet Company Name: Mailing Address'. 1 OP)177 -"? ti_1.1,=T_ oe„.! 1Q.„:0;4_,-±b,____,--r, Lai 1 s,_Hr) 403 ( Z.-2 City State Zip ICOlita,1 PCTSOVI4=1.:2/1.i.TH_LX1 2V_LIZ-1:5_____. _ __ — Day 'ilehlillonc3- 14_- e5C.,' 1 - 110(3 IFMRil Address: ag{66' ''Ci-) ie-0-11..)(6:15--tni-:cobc)_ Fax Nimiber:■:3 IA, '-_ 8 z.: I - ,4 162- z ,„ ,,,,,,,Ii:•,:i....,i.-.„:, 1•. ,,,,.„. ,„,„. ,...,:i., , riT6z.„, . ,T'.11111: 43;.-1-g: 1 Of (.'1 1,-11 • PLUMBING AND GAS PIPING PERMIT INFORMATION — 206 -431 =3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: ( rJ Mailing Address - - -- -- - -- - -- City - -- - — State - -Lip Contact Person: Day Telephone:__ l Mail Address:— - - - Fax Number: _ _ __ Contractor Registration Number: Expiration Date:. _ Valuation of Plun:lbing work (contractor's bid price): $ C_ i,T c ✓ter r , i ..,+11 ` 1 2 1�1:1 Valuation of Gas Piping work (contractor's' bid price): S OC.,+_T J -P i t~, Scope of Work (please provide detailed information) __&c)Lif-r _v1= c - ddU—Tc ( - - 00i-ot C i.i`lC �Lth nic "( S'( ii:A -1-t0 Building Use (per ;lnt'l Building Code): H'^". till l _tom Occupancy (per Int'l Building Code): 13- Utility Purveyor: Water: _- Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: n WOO,: i e ,.._ :. ''.0 , ty �<< F�xtuceType , Qh': �� iFixtiire�I ypez 4 ` .,Qfy,. ,.FixtureTy Q,a; . :; f Pty __ Bathtub or combination bath /shower - Drinking fountain or water cooler (per head) 2 Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic _ _ Floor drain 2 Sinks _ 1 Dental unit, cusI'idor __- -_ Shower, single head trap - _Urinals - Dishwasher, domestic, with inde sendent drain Lavatory Water Closet Building sewer or trailer .ark sewer _ Rain water system - per drain (inside building) Water heater and /or vent - 1 Additional medical gas inlets /outlets - six or more Industrial waste pretreatment interceptor, including its trap and vent; except for kitchen type grease interce tors Repair or alteration of water piping and /or water treating equipment 1 Repair or alteration of drainage or vent piping Medical gas piping system serving one to five- irilets /outlets for specific gas ,,” 1 < ; n n '.r;: -.,a ; , , . _ „i , Fh l';66: 5uic; • • PERMIT APPLICATION NOTES — Applicable,to all permits in this-application Value of Construction In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review Applications for which no pennit is issued within 180 days following the date of application shall expire by limitation. Building a.nd Mechanical Permit The, Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing andjustifiable cause demonstrated: Section 1053.2 International Building Code (current edition). Plurnbing.Perrnit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated: Section 103:4.3 Uniform Plumbing Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING'OWNER OR,f4Uii'HORIZED AGENT: Signatut�1'��_G -S�� Date: _ c �' /0P Print Name: ST Ev ELLSCid Day Telephone: LSI 4 - = 1 Od Mailing Address: I b 37-) x(-300 o o, _ST Lou IS, kb %3127 City State Zip Date Application Accepted: I Date Application Expires: Staff Initials: -)- —0 I( I -d-,)----oe _ n, ni'L �. - ■ 211nn Anpi • 2dUr. hh Pae:(01 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98.188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site http: / /www.ci.tukwila.wa.us RECEIPT Parcel No:: 6364200010 Permit Number: PG08 -055 Address: 656 SOUTHCENTER MALL'TUKW Status: _ Suite No Applied ate: 02/22/2008 Applicant: WHITE HOUSE Issue Date: Receipt No R08 =01482 Payment Amount: $224.00 Initials: User ID: Payee: JEM 1'165 Payment Date: 05/05/2008 11:57 AM Balance: $0.00 GREENWOOD CONSTRUCTION COMPANY TRANSACTION LIST: Type ,Method Descr;iptio Amount Payment Check 95276 224.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLUMBING - NONRES 000:322.103.00.0 224.00 Total: $224.00 1991 05/05 9711 TOTAL 224°00 doc: Receiot -06 Printed: 05 -05 -2008 ® • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206=431 =3665 Web site: http://www.ci.tukrvi/a.wa.us SET RECEIPT RECEIPT NO R08 =00503 Initials: WEE User ID: 1655 Payee: CASCO Payment Date: 02/22/2008 Total Payment: 2,267.55 SET ID: 2008 SET NAME: WHITE HOUSE SET TRANSACTIONS: Set Member Amount 'D08 -100 1,925.30 EL08 -178 205.00 M08 -053 90.25 P,G08C 47:00 TOTAL: 2,267.55 TRANSACTION LIST: Type Method Description Amount Paymett Check 800418 ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES PLAN 'CHECK = NONRES TOTAL: 2,267.55 2,267.55 Account Code Current Pmts 000.345.832.00.0 205.00 000/345:830 2,062.55 TOTAL: 2,267.55 P''73 02/ 22 'C10 TOTAL 2x 67 =55 E� 9 arrerre _s INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD a ASS 1 1) Retain a copy with permit /L2a� PERMIT NO. Projec : Type of Inspection: Address: 656 77?i9 /( Date Called: Special Instructions: Date Wanted:Y 5 • Qu p.m. Requester: PC/ ;of c;),70 ^ zi/i2 7 NApproved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: !`i /Y%O /eJC Inspector: Date: 7/9/Q $60.0 ,NSPECTION FEE REQUIRED. Prior to inspection, fee must be paid t 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: ._ec._ ....a- .,..11ma Rea. 1. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila,•WA 98188 INSPECTION RECORD Retain a copy with permit • PERMIT NO. (206)431 -3670 Pr je t. r i -e 114- Type ns1pectior. — i / /°°��' A dress• Date Calleaad :ll Special Instructions: Date ant22 - jam` • �.p Requester: P.4i I:4ra Li 6Z.7 • m( Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: Inspector: Date: c-4,4 ❑ $58.0 EINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)43 1 -3670 Project: Type oo ction: 4 q t_ AddyelI ps4 K // Date Called: SeecialIns ructions: . Date Wanted: a.m. .5--/3 —ate Requester: Phone No: �o l _ 870 "4/62"7 Approved per applicable codes. 12korrections required prior to approval. /2 COMMENTS: 21/414)/4/41,12b0iMV 4pp/4/1e specto J2,-4 Aieu Date: r4K REINSPECTION FE REQ RED. Prior o inspection, fee must be at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: NAME 1)M 105. City of Tukwila — Public Works Maintenance Department 600 Minkler Blvd, Tukwila, WA 98188 Backflow Assembly Test Report Form u4 '1 1-it=uS2 itioarkcouNT # _ ..... _ SERVICE ADDRESS G,'"--,(4; tri- °I/30 METER # CITY II) '&4411 LA- STATE tA)1■1 _ ZIP CODE ct 6/ ASSEMBLY LOCATION /5' Fi-sok/ca- (A)0P4 R-C-y-'`7 IA/ CROSS-CONNECTION CONTROL FOR? 60/14(377C- - - SIZE 3 / (-1 MAKE kti'1:111-3 MODEL 06 CV fl TYPE 7:A.-..-VKN SN 6Q-.6n4 _ - LINE PRESSURE AT TIME OF TEST? RP DC PV PSI NEW? EXISTING? El REPLACEMENT? 0 BA INITIAL TEST RESULTS TESTS AFTER REPAIR OR CLEANING PSI DROP ACROSS #1 CHECK VALVE RELIEF VALVE OPENED 0 CHECK VALVE CLOSED TIGHT? #1 CHECK VALVE LEAKED? #2 CHECK VALVE CLOSED TIGHT? #2 CHECK VALVE LEAKED? APPROVED AIR GAP PROVIDED? RPBA PASSED TEST? Yes ----- No PSID PSID PSI DROP ACROSS #1 CHECK VALVE PSID PSID RELIEF VALVE OPENED #1 CHECK VALVE CLOSED TIGHT? #1 CHECK VALVE LEAKED? #2 CHECK VALVE CLOSED TIGHT? #2 CHECK VALVE LEAKED? APPROVED AIR GAP PROVIDED? RPBA PASSED TEST? Yes No VA BA $11 CHECK VALVE CLOSED TIGHT? $11 CHECK VALVE LEAKED? h 2 CHECK VALVE CLOSED TIGHT? #2 CHECK VALVE LEAKED? DCVA PASSED TEST? Yes 2 ' ‘f 2_ - . No PSID PSID #1 CHECK VALVE CLOSED TIGHT? #1 CHECK VALVE LEAKED? #2 CHECK VALVE CLOSED TIGHT? #2 CHECK VALVE LEAKED? DCVA PASSED TEST? Yes No PSID PSID fl _ AIR INLET OPENED AT AIR INLET FAILED TO OPEN? CHECK VALVE HELD TIGHT AT CHECK VALVE LEAKED? PVBA PASSED TEST? Yes No PSID PSID AIR INLET OPENED AT AIR INLET FAILED TO OPEN? CHECK VALVE HELD TIGHT AT __ PSID PSID CHECK VALVE LEAKED? PVBA PASSED TEST? Yes No APPROVED ASSEMBLY? REMARKS PROPER INSTALLATION? INSPECTED BY CCS? TEST COMPANY PHONE TEST KIT MAKE (4IPtAJT MODEL a--t'S— SN ()‘°'-'77a, CALIBRATION DATE 2- - -2- Le I certifi, that I used WAC 246-290-490 approved Test Methods and Differential Pressure Test Equipment TESTER'S NAME (PRINTED) -.I CERTIFICATION # -7 - SIGNATURE REPAIRED BY RETESTED BY DATE TESTED REPAIR DATE CERT # DATE TESTED .... PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG08 -055 DATE: 02 -22 -08 PROJIECT NAME: WHITE HOUSE SITE ADDRESS: 656 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: .�&/ Buifdinf Divisionv blic Works ►.r.' NIL. 2 -2�- Fire Prevention Structural Planning Division n Permit Coordinator DE ERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 02 -26 -08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:_ LETTER OF COMPLETENESS MAILED: TUES/THURS RO TING: Please Route Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: _ DUE DATE: 03-25 -08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slipidoc 2 -28 -02 Look Up a Contractor, Electrilp or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance: License Information License MANZCP *926B8 Licensee Name MANZCO PLUMBING Licensee Type CONSTRUCTION CONTRACTOR UBI 602699643 Ind: Ins. Account Id SECRETARY Business Type CORPORATION Address 1 PO BOX 822964 Address 2 City VANCOUVER County CLARK State WA Zip 98682 Phone 3607728149 Status ACTIVE Specialty 1 PLUMBING Specialty 2 UNUSED Effective Date 1/28/2008 Expiration Date 1/28/2010 Suspend Date Separation Date Parent Company RECON, INC Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date MANZHURA, MIKHAIL PRESIDENT 01/28/2008 Bond Amount MANZHURA, VLADIMIR SECRETARY 03/13/2008 MANZHURA, MARGARITA VICE PRESIDENT 01/28/2008 • Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date Page 1 of 2 https:// fortre ss.wa.gov /lni/bbip /printer.aspx ?License= MANZCP *926B8 05/05/2008 ( 50 CFM 6" DIA. NECK 12 50 CFM - 6" DIA. NECK SCALE = 1/2" = 1' -0" 22 "x10" NECK 20x18 ENLARGED PLUMBING PLAN 210 CFM 8" DIA. NECK 410 CFM 10 "DIA. NECK' (8) (13.8 FD -1 v 7 18 x16 D 175 CFM 6" DIA. NECK WHA -1 �. 1/2" CW 3/4" —\ CW 3/4" O 1 210 CFM 8" DIA. NECK 1 O 175CFM 6" DIA. NECK WC -1 WC -1 2 "V 1/2" CW (TYP) 3/4" CW TP -1 3/4" CW LAV -1 1/2" HW (TYP) 1 -1/2" SAN 3/8" CW 3" SAN 2 "V 3/4" HW 1 -1/2" v 4 VENT 3/4" HW 1/2" CW (TYP) LAV -1 1 -1/2" SAN (TYP) FD -1 3/4" CW 1 -1/2 "V 1 -1/2" SAN 3/4" HW DF -1 / 1/2" Cw 4" SAN 3/4" CW 3/4" HW CW 3/4" WH -1 3/4" CW 2 "V MS -1 3" SAN HW WCO -1 3" SAN 3 "V 3" SAN 3/4" CW 4" SAN 4" —\;-- SAN 3 „ SAN 4 „ � - SAN 4" SAN 3/4" CW 2 "V I 3/8" CW 4" SAN 3/4" CW 4" SAN SCALE = N.T.S. CW 4" SAN 2 "V 1/2" CW 4" SAN PLUMBING ISOMETRIC LANDLORD NOTES TENANT'S CONTRACTOR SHALL MAINTAIN A MINIMUM OF 6" UNOBSTRUCTED CLEARANCE HEIGHT IN RETURN AIR PLENUM ABOVE CEILING ALLOWING FOR AIR FLOW BACK TO LANDLORD AIR CONDITIONING UNIT. ALL TENANTS ON THE GROUND FLOOR REQUIRING BELOW GRADE WORK SHALL COORDINATE WITH LANDLORD PRIOR TO ANY SLAB DEMOLITION. TENANT'S CONTRACTOR SHALL COORDINATE WITH LANDLORD TO PROVIDE OPPORTUNITY FOR SPECIAL INSPECTION AND PHOTOGRAPHIC DOCUMENTATION BY LANDLORD OF BELOW GRADE WORK PRIOR TO THE COVERING UP OF SUCH WORK. TENANT'S CONTRACTOR SHALL BE RESPONSIBLE FOR RECONSTRUCTION AND PATCHING OF THE SLAB -ON -GRADE SYSTEM, INCLUDING GRAVEL LAYERS, VAPOR BARRIER, AND CONCRETE. TENANT'S CONTRACTOR SHALL PROVIDE A FIRE WATCH AND PORTABLE FIRE EXTINGUISHER WHERE ANY WELDING IS DONE WITHIN THE DEMISED PREMISES. THE PERSON PERFORMING THE FIRE WATCH SHALL REMAIN IN THE TENANT SPACE FOR AT LEAST 1 HOUR AFTER THE COMPLETION OF ANY WELDING, THIS SHALL BE COORDINATED THROUGH THE CITY OF TUKWILA FIRE DEPARTMENT. WHA -1 2 "V 4" SAN WCO -1 2 3 4 6 7 8 10 11 175 CFM 6" DIA. NECK 175 CFM 6" DIA. NECK OPENING IN CLOSET AREA FOR RETURN AIR. SEE DETAIL 2/A5.2 FOR ADDITIONAL INFORMATION (TYP. OF BOTH CLOSETS). 0 170CFM 6" DIA. NECK 16x10 ECHANICAL KEYED NOTES "®" 51- SUPPLY AIR DEVICE "TITUS" OMNI 24 "X24 ". PROVIDE VOLUME DAMPER AS SHOWN ON DIFFUSER MOUNTING SCHEMATIC (SHEET MP2). FRAME TYPE 3 AND TRM RAPID MOUNT FRAME. WHITE FINISH. S2- SUPPLY AIR DEVICE "TITUS" OMNI 12 "X12 ". PROVIDE VOLUME DAMPER AS SHOWN ON DIFFUSER MOUNTING SCHEMATIC (SHEET MP2). FRAME TYPE 3 AND TRM RAPID MOUNT FRAME. WHITE FINISH. S3- SUPPLY AIR DEVICE "TITUS" OMNI 24 "X24 ". PROVIDE VOLUME DAMPER AS SHOWN ON DIFFUSER MOUNTING SCHEMATIC (SHEET MP2). FRAME TYPE 3. WHITE FINISH. EXHAUST AIR DEVICE "NUTONE" MODEL 672R 9 "X9" LOUVERED FACE. PROVIDE VOLUME DAMPER. EXTEND & CONNECT NEW EXHAUST TO LANDLORD'S EXISTING EXHAUST DUCT. TRANSITION AS REQIURED. CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION AND CONNECTION REQUIREMENTS PRIOR TO SUBMITTING BID. R2- RETURN AIR DEVICE "TITUS" 355RL 24 "X12" LOUVERED FACE. FRAME TYPE 3. WHITE FINISH. CONTRACTOR SHALL INSTALL WITH LOUVER OPENINGS FACING WALL. MOUNT THERMOSTAT ON WALL 48" TO 56" AFF. LOCATE REMOTE SENSORS AT THE DIRECTION OF CHICO'S PROJECT MANAGER. NOTE THAT "I" STAT BY LIGHTSTAT IS CUSTOM PROGRAMMED FOR EACH CHICO'S LOCATION AND MUST BE ORDERED BY CONTRACTOR AT AWARD OF JOB TO ENSURE ON TIME DELIVERY. EXTEND NEW 3" VENT TO 3" VENT STUB -IN. FIELD VERIFY LOCATION OF STUB -IN PRIOR TO INSTALLING ANY PIPING. EXTEND NEW 4" SANITARY PIPING TO EXISTING SANITARY. FIELD VERIFY EXACT LOCATION, SIZE, AND INVERT ELEVATION PRIOR TO INSTALLING PIPING. CONTRACTOR SHALL OBTAIN APPROVAL AND REQUIREMENTS FOR ALL TRENCHING WITH LANDLORD'S ON -SITE REPRESENTATIVE PRIOR TO INSTALLING ANY PIPING. EXTEND NEW 3/4" DOMESTIC WATER TO 3/4" WATER STUB -IN. FIELD VERIFY EXACT LOCATION PRIOR TO INSTALLING NEW PIPING. PROVIDE REDUCED PRESSURE BACKFLOW PREVENTER AND WATER METER WITH REMOTE READER IF REQUIRED. VERIFY REQUIREMENTS WITH LANDLORD'S FIELD REPRESENTATIVE AND LOCAL UTILITY. CONTRACTOR SHALL ROUTE DUCTWORK TO AVOID ALL EXISTING WATER, GAS, SPRINKLER PIPING, BEAMS, JOISTS, ETC. CONTRACTOR SHALL FIELD VERIFY ALL PRIOR TO INSTALLING ANY DUCTWORK. SMOKE DETECTOR IN RETURN AIR TO SHUT DOWN UNIT AND CLOSE ALL DAMPERS ON SIGNAL. WIRE SMOKE DETECTOR TO BUILDING ALARM SYSTEM OR A REMOTE AUDIONISUAL DEVICE WITH MANUAL RESET LOCATED IN A CONSTANTLY MONITORED LOCATION. 12 EXTEND AND CONNECT 8" DIA. EXHAUST DUCT TO EXISTING EXHAUST DUCT. FIELD VERIFY EXACT SIZE AND LOCATION PRIOR TO BID. CONTRACTOR SHALL VERIFY ALL CONNECTION REQUIREMENTS PRIOR TO BID. FILE COPY6 .055 Permit No Pier review approval is subject to errors and orn€s; ices. Approval of construction documents does not authr ri the violation of a : dopted code or ordinance. Peri4n.i of approver • geld Cop and cons Lions is vicr cd! Date71111111P 5 City ofTu ,vg t~ ` t s DIN DI ,, ri LION 175 CFM 6" DIA. NECK 6" DIA. NECK jpo MRR - 20111 t.' �f TU\(M\a BUILDING D ..5I .... A.) B.) C.) D.) E.) F.) G.) H.) 8x10 175 CFM 6" DIA. NECK -� 175 CFM 6" DIA. NECK R ISiOiS No changes sha be made to the scope of work wit prior approval of Tukwila uilding Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. EF GENERAL NOTES SEPARATE PERMIT REQUIRED FOR: ti1 i � t fffElectricaa ik a Plumbing 0 Gas Piping City of Tukwila u$ vtit PGo8 C. #C0018 IRES 07/21/ Ph. 314. 821. 1100 Fax 314. 821. 4162 Email chicos @cascacarp.com HVAC & PLUMBING FLOOR PLAN 0'r /o /o c0n7171 z n , / v',','f ;'', PH( f f f'NUf• S C. ALBERTS drawn by scale of HE L ul•'I� I l,lt; 1 ,15-; Ity111,1tod DUCT SIZES SHOWN ARE SHEET METAL DIMENSIONS. NO DUCT LINER. PROVIDE SINGLE WALL TURNING VANES @ ALL ELBOWS AND TEES PER SMACNA STANDARDS. DO NOT PROVIDE AIR EXTRACTORS OR SPLITTER DAMPERS WHICH PROTRUDE INTO RECTANGULAR TRUNK DUCTS. PROVIDE ROUND SPIN -IN FITTINGS FOR ROUND BRANCH DUCTS. ROUND BRANCH DUCTS ARE SAME SIZE AS DIFFUSER WHICH IT SERVES. CONTRACTOR SHALL FIELD VERIFY THE EXACT SIZE, LOCATION, AND CONDITION OF ALL EXISTING EQUIPMENT, PIPING, DUCTWORK, ETC. TO BE REUSED, RETAINED OR CONNECTED TO. CONTRACTOR SHALL IDENTIFY ROOF MOUNTED EQUIPMENT WITH STORE NAME AND UNIT NUMBER USING PERMANENT, WEATHER PROOF 2" HIGH DIE -CUT LETTERS. CONTRACTOR SHALL COMPLY WITH ALL LANDLORD'S TENANT CRITERIA. COORDINATE AND SCHEDULE ALL WORK WITH LANDLORD'S FIELD REPRESENTATIVE. MAXIMUM FLEXIBLE DUCT LENGTH SHALL NOT EXCEED 5' -0 ". FLEXIBLE DUCTS SHALL BE INSTALLED TO PROVIDE SWEEPING CONFIGURATIONS WITH NOT LESS THAN MANUFACTURER'S RECOMMENDED BEND RADIUS, WITHOUT UNDUE RESTRICTIONS, BUT NOT CREATING UNNECESSARY SAGS OR CURVES. FLAT BANDING MATERIAL NOT LESS THAN 1 -1/2" WIDE SHALL BE USED TO SUSPEND FLEXIBLE DUCTING. DUCTING FURNISHED WITH FACTORY INSTALLED GROMMETS SHALL BE SUSPENDED BY WIRES ATTACHED TO GROMMETS. WHERE CEILING SPACE 15 NOT SUFFICIENT TO PERMIT TOP CONNECTION TO CEILING DIFFUSER WITH PROPER BEND RADIUS FOR FLEXIBLE DUCT, CONTRACTOR SHALL FABRICATE AND /OR PROVIDE AN ADAPTER BOX FOR DIFFUSER TO PERMIT SIDE CONNECTION OF FLEXIBLE DUCT. I.) CONTRACTOR SHALL PROCURE THE SERVICES OF A LANDLORD APPROVED NEBB OR AABC CERTIFIED AIR BALANCE & TESTING AGENCY TO BALANCE, ADJUST & TEST EQUIPMENT. CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING 3 COPIES OF BALANCE/TEST AGENCY'S REPORT TO CHICO'S PROJECT MANAGER AND LANDLORD'S REPRESENTATIVE FOR REVIEW. J.) BALANCING OF AIR DEVICES SHALL BE ACCOMPLISHED BY ADJUSTING BRANCH TAKEOFF DAMPER AT MAIN TRUNK DUCT. DAMPERS IN THE NECKS OF AIR DEVICES SHALL BE USED FOR FINAL TRIM ONLY, AND IN NO CASE FOR GREATER THAN 10% OF THE INDICATED VOLUME FOR THE INDIVIDUAL AIR DEVICE. K.) CONTRACTOR SHALL PROVIDE ALL WATER, WASTE AND VENT PIPING AS REQUIRED TO MAKE A COMPLETE AND WORKING SYSTEM IN EVERY RESPECT. ALL WORK SHALL COMPLY WITH ALL STATE AND LOCAL CODES AND THE STANDARDS AND REQUIREMENTS OF THE LANDLORD. FIELD VERIFY ALL LOCATIONS AND SIZES OF UTILITES. L.) ANY PENETRATION THROUGH THE ROOF SHALL BE COORDINATED WITH THE LANDLORD'S FIELD REPRESENTATIVE AND SHALL BE DONE BY A LANDLORD APPROVED ROOFING CONTRACTOR TO MAINTAIN THE ROOFING WARRANTY. M.) TENANT /MALL CRITERIA DOCUMENTS SHALL BE CONSIDERED A PART OF THE CONSTRUCTION DOCUMENTS. TENANT CONTRACTOR SHALL COMPLY WITH ALL REQUIREMENTS STATED THEREIN WHETHER SPECIFICALLY DESCRIBED ON THE DRAWINGS OR NOT. N.) DO NOT SUSPEND ANY ITEMS FROM DECK OR SLAB ABOVE. ALL ITEMS SHALL SUSPENDED FROM STRUCTURE UNLESS OTHERWISE NOTED. PROVIDE MISCELLANEOUS STEEL AS REQUIRED. FEB 2 2 2008 PE-- �','y SUPPLY FIXTURE UNITS FIXTURE NUMBER WATER SUPPLY FIXTURE UNITS TOTAL COLD HOT DRINKING FOUNTAIN 1 0.25 - -- 0.25 FLOOR DRAIN + -CVIN - -- - -- 1 4 MOP SINK rNIN 2.25 2.25 1.5 3 2 LAVATORY _ 1,5 TANK TYPE WATER CLOSET (1.6GPF) _ 5 - -- 5 TOTAL WATER SUPPLY FIXTURE UNITS TOTAL PEAK DEMAND (GPM) 10.25 15.4 NOTE: THE 2006 IPC, TABLE E103.3(2); "LOAD VALUES DEMAND DETERMINED FROM THE 2006 IPC, ESTIMATING DEMAND." LOAD VALUES TAKEN FROM ASSIGNED TO FIXTURES.+' TOTAL TABLE E103.3(3): "TABLE FOR DRAINAGE FIXTURE UNITS FIXTURE NUMBER DRAINAGE FIXTURE UNITS TOTAL DRINKING FOUNTAIN 57 0.5 FLOOR DRAIN 2 2 MOP SINK + -CVIN I c iN LAVATORY 1 4 TANK TYPE WATER CLOSET (1.6GPF) TOTAL DRAINAGE FIXTURE UNITS MINIMUM PIPE SIZE REQUIRED: 3" PIPE SIZE ON PLAN: 4" 16.5 NOTE: THE 2006 IPC, TABLE 709.1: "DRAINAGE AND GROUPS." PIPE SIZE IPC, TABLE 710.1(2): "HORIZONTAL LOAD VALUES TAKEN FROM FIXTURE UNITS FOR FIXTURES DETERMINED FROM THE 2006 FIXTURE BRANCHES AND STACKS," REQ INLET PRESSURE (IN. W.C.) EXTERNAL STATIC (IN. W.C.) 0.5 FAN BHP 3/4 PRIMARY AIR TEMP F) MAX SUPPI CFN 0.25 57 2500 GENERAL MECHANICAL CONDITIONS 1. THE GENERAL AND SPECIAL CONDITIONS OF THE ARCHITECTURAL DRAWINGS SHALL BE ED AS PART OF THESE DOCUMENTS. 2. ALL MATERIALS SHALL BE NEW, UNUSED, AND THE BEST OF THEIR RESPECTIVE KINDS AND FREE FROM DEFECTS. 3. THE L,L)IN 1 RACTOR SHALL FURNISH AND INSTALL A COMPLETE AIR DISTRIBUTION SYSTEM WITHIN THE TENANT SPACE TO INCLUDE, BUT NOT LIMITED TO ALL DUCTWORK, HANGERS, INSULATION, VAPOR BARRIER, SUPPLY DIFFUSERS, RETURN GRILLES, FLEXIBLE CONNECTIONS, AND CONTROL INSTALLATION AS REQUIRED FOR A COMPLETE AND WORKING SYSTEM. THE CONTRACTOR SHALL PAY ALL FEES, GIVE ALL NOTICES, FILE ALL NECESSARY DRAWINGS AND OBTAIN ALL PERMITS AND CERTIFICATES OF APPROVAL REQUIRED IN CONNECTION WITH ALL WORK UNDER THIS CONTRACT. ALL WORK SHALL BE FURNISHED AND INSTALLED IN FULL ACCORDANCE WITH ALL LOCAL LAWS, ORDINANCES, RULES AND REGULATIONS. 4. DRAWINGS ARE DIAGRAMMATIC ONLY, INTENDING TO SHOW GENERAL RUNS AND LOCATIONS OF THE WORK AND ARE NOT INTENDED TO BE RIGID IN SPECIFIC DETAIL, 5. THE CONTRACTOR SHALL BE HELD TO HAVE EXAMINED THE SITE FOR HIS WORK BEFORE HAVING SUBMITTED HIS PROPOSAL, NO ADDITIONAL COMPENSATION WILL BE ALLOWED FOR CONDITIONS FOUND DURING THE COURSE OF THE CONTRACT. 6. THE CONTRACTOR SHALL VERIFY ALL MEASUREMENTS AT THE SITE AND BE RESPONSIBLE FOR THE CORRECTNESS OF THE SAME. 7. THE CONTRACTOR SHALL COORDINATE THE INSTALLATION OF HIS WORK WITH LIGHTING PLANS, REFLECTED CEILING PLANS, LANDLORD'S SPRINKLER PLANS AND ALL OTHER TRADES, 8. THE INSTALLATION OF ALL EQUIPMENT AND MATERIALS REQUIRING ACCESS SHALL BE MADE IN SUCH MANNER AS TO MAKE THE EQUIPMENT AND MATERIALS READILY ACCESSIBLE FOR OPERATION, MAINTENANCE AND REPAIRS. 9. STORAGE OF CONSTRUCTION EQUIPMENT AND MATERIALS SHALL BE ONLY IN SPACES AS DESIGNATED BY THE ARCHITECT /OWNER. 10. CONSTRUCTION DEBRIS AND RUBBISH GENERATED BY THE CONTRACTOR SHALL BE REMOVED FROM PREMISES DAILY TO MAINTAIN A CLEAN AND WORKABLE AREA. 11. ALL WORK AND EQUIPMENT SHALL BE FULLY GUARANTEED FOR ONE (1) YEAR FROM THE DATE OF FINAL PAYMENT AND ACCEPTANCE. 12. ALL WORK, INCLUDING INSIDE OF SUPPLY AIR DUCTS, AND EQUIPMENT WITHIN THE CONTRACT AREA FURNISHED AND INSTALLED UNDER THIS CONTRACT SHALL BE CLEANED TO THE SATISFACTION OF THE OWNER BEFORE TURNING SAME OVER TO THE OWNER. 13. CONNECT NEW WORK TO EXISTING IN A NEAT AND APPROVED MANNER. 14. INTERRUPTION OF HEATING, POWER AND AUXILIARY SYSTEMS WHERE AND IF REQUIRED SHALL BE COORDINATED AND SHALL OCCUR ONLY DURING PREARRANGED ACCEPTABLE TIMES, 15. ALL DESIGN SHALL INCORPORATE CURRENT ASHRAE METHODS. 16. WHEN EXISTING DUCTWORK IS UTILIZED, SIZES SHALL BE AS SHOWN ON DWGS. AS MINIMUM REQUIREMENT. FIRE PROTECTION STANDARDS 1. THE CONTRACTOR SHALL RETAIN AND PAY FOR A "PROFESSIONAL OF RECORD" FOR ALL FIRE SPRINKLER AND FIRE PROTECTION WORK. 2. THE DRAWINGS AND ALL SPECIFICATIONS FOR ALL FIRE PROTECTION WORK ARE PERFORMANCE IN SCOPE AND INTENT. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MATERIALS, EQUIPMENT, LABOR, DESIGN, LAYOUT, DETAILS, DRAWINGS, DOCUMENTS, AND ALL CRITERIA TO MEET GOVERNING AUTHORITIES, CODES, REGULATIONS, AND UNDERWRITER'S REQUIREMENTS FOR ALL FIRE PROTECTION WORK. 4. CONTRACTOR SHALL VISIT THE SITE TO BECOME FAMILIAR WITH THE EXISTING CONDITIONS PRIOR TO SUBMITTING BID. 5. A COMPLETE SET OF ALL REQUIRED DOCUMENTS SHALL BE PREPARED AND SUBMITTED TO THE PROPER AUTHORITIES WITHIN THIRTY (30) DAYS OF CONTRACT AWARD. 6. THE LANDLORD'S DESIGN CRITERIA SHALL BE CONSIDERED PART OF THESE SPECIFICATIONS. 7. ALL FIRE PROTECTION WORK SHALL BE SCHEDULED IN ADVANCE WITH THE LANDLORD'S FIELD REPRESENTATIVE. FIRE PROTECTION SYSTEM SHALL BE FULLY OPERATIONAL WHEN THE CONTRACTOR IS OFF THE SITE. PLUMBING SPECIFICATION 1. PROVIDE A COMPLETE AND OPERATING PLUMBING SYSTEM AS INDICATED ON THE DRAWINGS. THE INSTALLATION SHALL BE COMPLETE WITH ALL FIXTURES, FITTINGS, TRIM AND ACCESSORIES TO PROVIDE A COMPLETE, FUNCTIONING SYSTEM, PROVIDE FOR ALL CODE REQUIREMENTS AND DISABILITY PROVISIONS. 2. PROVIDE SQUARE TOP CLEANOUT COVERS ON FLOOR CLEANOUTS. SQUARE COVERS SHALL BE ALIGNED WITH BUILDING CONSTRUCTION AND FLUSH WITH FINISHED FLOOR. 3. SUPPLY PIPING SHALL BE TYPE "L" COPPER INSTALLED WITH LEADLESS SOLDER. SANITARY WASTE AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON WITH HUBLESS CONNECTOR FITTINGS ABOVE GRADE. BELOW GRADE SHALL BE SERVICE WEIGHT CAST IRON HUB AND SPIGOT GASKET JOINT. HOT AND COLD WATER SUPPLY PIPING SHALL BE INSULATED WITH A MINIMUM 1/2" FIBERGLASS WITH VAPOR PROOF ALL SERVICE JACKET OR EQUIVALENT CLOSED CELL FOAM INSULATION AS ALLOWED BY LOCAL CODES FOR INSTALLATION IN RETURN AIR PLENUMS. 4. ALL VALVE HANDLES SHALL BE COLOR CODED IN ORDER SO THAT THEY SHALL CORRESPOND AS FOLLOWS: A. BLUE - COLD WATER B. RED - HOT WATER 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PIPING SUPPORTS, HANGERS AND METHODS FOR ATTACHMENT TO WALLS AND PARTITIONS. 6. NO PIPING SHALL RUN THROUGH DUCTWORK. 7, CONTRACTOR SHALL VERIFY ALL DIMENSIONS, SPACES AND CONDITIONS PRIOR TO FABRICATION AND INSTALLATION OF EQUIPMENT AND MATERIAL. 8. CONTRACTOR SHALL GUARANTEE ALL WORK FREE FROM DEFECTS OF WORKMANSHIP AND /OR MATERIAL FOR A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE. 9. DIELECTRIC UNIONS SHALL BE PROVIDED WHEREVER DISSIMILAR METALS ARE JOINED. 10. REFER TO PLUMBING FIXTURE SCHEDULE FOR SPECIFICATIONS FOR NEW FIXTURES AS REQUIRED. MECHANICAL SPECIFICATIONS 1. AIR BALANCING A. CONTRACTOR SHALL PROCURE THE SERVICES OF AN INDEPENDENT NEBB OR AABC CERTIFIED AIR BALANCE AND TESTING AGENCY TO BALANCE, ADJUST & TEST EQUIPMENT. CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING 3 COPIES OF BALANCE/TEST AGENCIES REPORT TO CHICO'S PROJECT MANAGER AND LANDLORD OPERATIONS DIRECTOR FOR REVIEW. MIN. OUTDOOR C.F.M. AND INDOOR FAN C.F.M. SHALL BE PROVIDED AS SHOWN ON RTU SCHEDULE (NOTE: BALANCE MUST BE WITHIN ± 5% OF DESIGN). 2. DUCTWORK A. INSTALL ALL DUCTWORK IN COMPLETE CONFORMANCE WITH RECOMMENDED CONSTRUCTION STANDARDS FOR RECTANGULAR AND ROUND SHEET METAL AND FLEXIBLE DUCTS IN ACCORDANCE WITH SMACNA DUCT CONSTRUCTION STANDARDS AND ALL OTHER AUTHORITIES HAVING JURISDICTION. FLEXIBLE DUCT SHALL NOT EXCEED 5' -0" IN LENGTH. MINIMUM SHEETMETAL THICKNESS SHALL BE 26 GA. B. ALL DUCT JOINTS SHALL BE SEALED PER SMACNA SEAL CLASS "C" USING DUCT SEAL AS MANUFACTURED BY UNITED SHEET METAL, OR EQUAL. GRAY DUCT TAPE SHALL NOT BE ACCEPTED. C. STRAP HANGERS SHALL NOT BE LESS THAN 1" BY 1/8" THICK ON SIX (6) FOOT CENTERS AND ATTACHED TO SIDE OF DUCT WITH SHEET METAL SCREWS. INSULATED FLEXIBLE DUCT MAY BE USED FOR LOW PRESSURE RUNOUTS TO INDIVIDUAL DIFFUSERS IN LENGTHS NOT TO EXCEED FIVE (5) FEET FOR EACH DIFFUSER. SEAL ALL SHEETMETAL SCREW PENETRATIONS. D. ALL RECTANGULAR AND ROUND SUPPLY DUCTWORK SHALL BE EXTERNALLY INSULATED WITH A MINIMUM THICKNESS THAT CONFORMS TO THE STANDARD OF THE GOVERNING CODE AND SHALL IN NO CASE BE LESS THAN 2" AND SHALL HAVE A CONTINUOUS VAPOR BARRIER JACKET W /ALL JOINTS TAPED AND SEALED. E. PROVIDE FLEXIBLE CONNECTION BETWEEN ALL FAN POWERED EQUIPMENT AND CONNECTING DUCTWORK. F. ALL INSULATION, JOINING MATERIALS, SEALER, ETC.. SHALL HAVE A U.L. FLAME SPREAD CLASSIFICATION OF NO MORE THAN 25 AND A SMOKE DEVELOPMENT RATING NOT MORE THAN 50. 3, AIR DEVICES A. SUPPLY DIFFUSERS: (TITUS AS STANDARD) SHALL BE FURNISHED WITH BAKED WHITE ENAMEL FINISH, AND SHALL BE SELECTED FOR NECK VELOCITIES NOT EXCEEDING 800 FPM AND NOISE LEVEL OF NC -35 OR LESS. B. SUPPLY DIFFUSERS SHALL BE ROUND NECK, STEEL, MODEL OMNI, SIZED USING CRITERIA INDICATED ABOVE FOR LAY -IN CEILING GRID TYPE CONSTRUCTION OR DRYWALL CEILING AS INDICATED ON DWG. DIFFUSERS SHALL BE COMPLETE WITH ADJUSTABLE AIR PATTERNS AS REQUIRED (REFER TO HVAC /PLUMBING PLAN, SHEET MP1). C. RETURNS SHALL BE 22 INCH SQUARE NECK (ROUND IN STORAGE) STEEL, PERFORATED FACE MODEL PAR. FACE VELOCITY OF RETURN REGISTERS SHALL NOT EXCEED 500 FPM. VOLUME CONTROL DAMPER NOT REQUIRED FOR RETURN INSTALLATION. D. COORDINATE LOCATION OF AIR DEVICES WITH LIGHTS, SPRINKLERS, SPEAKER, SMOKE DETECTORS, ETC. 4. EQUIPMENT A. REFER TO MECHANICAL PLANS FOR SPECIFICATIONS OF HVAC EQUIPMENT. B. ALL NEW EQUIPMENT SHALL BE EQUIVALENT TO THE SPECIFIED ITEM. ANY ACCOMMODATIONS FOR ALTERNATE MANUFACTURERS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. C. MOUNT NEW EQUIPMENT USING VIBRATION MOUNTS OR HANGERS MOST SUITABLE FOR THE APPLICATION. D. ALL EQUIPMENT SHALL BE INSTALLED ACCORDING TO MANUFACTURERS INSTRUCTIONS. E. EXISTING EQUIPMENT TO REMAIN SHALL BE CLEANED AND SERVICED TO RENDER IT FULLY OPERATIONAL. CONTRACTOR TO ADVISE TENANT OF COMPONENTS AND /OR CONTROLS, WHICH NEED TO BE REPLACED. F. COORDINATE UNIT LOCATION WITH LANDLORD AND SITE CONDITIONS. G. INSTALL GAS PIPING AND CONNECT TO NEW UNITS. FIELD VERIFY GAS METER LOCATION AND SIZE. INSTALL GAS REGULATOR WHERE REQUIRED. H. GAS PIPING SHALL BE SCHEDULE 40 (ASTM -Al20) BLACK STEEL WITH 300 Ib. BLACK FULLY OPERATIONAL. MALLEABLE IRON BANDED SCREWED OR WELD PATTERN FITTINGS AS APPLICABLE. I. ALL PIPING AND FITTINGS LOCATED OUTDOORS AND ABOVE GRADE SHALL BE CLEANED FREE OF RUST AND PAINTED. ALL FITTINGS TO BE MADE WITH PIPE JOINT COMPOUND. TEFLON TAPE NOT ALLOWED. 5. CONTROLS A. PROVIDE CONTROLS AS SPECIFIED. SPECIAL CONTROL METHODS WILL BE ADDRESSED ON AN INDIVIDUAL BASIS. B. THE CONTRACTOR SHALL PROVIDE ALL 24V WIRING INCLUDING CONNECTIONS, CHECK, TEST AND START -UP. C. COORDINATE INTERFACING OF DUCT MOUNTED SMOKE DETECTOR (WHEN SPECIFIED OR REQUIRED) WITH ELECTRICAL CONTRACTOR TO STOP FAN. DOCUMENTATION CONSTRUCTION DOCUMENTS SHALL REQUIRE THAT WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. CONSTRUCTION DOCUMENTS SHALL REQUIRE AN OPERATING MANUAL AND MAINTENANCE MANUAL BE PROVIDED TO THE BUILDING OWNER. THE MANUAL SHALL BE IN ACCORDANCE WITH INDUSTRY ACCEPTED STANDARDS AND SHALL INCLUDE, AT A MINIMUM, THE FOLLOWING: 1. SUBMITTAL DATA STATING EQUIPMENT SIZE AND SELECTED OPTIONS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE. ALL OTHER HVAC CONTROL SYSTEMS, AND OTHER AUTOMATICALLY CONTROLLED SYSTEMS FOR WHICH ENERGY CONSUMPTION, PERFORMANCE, OR MODE OF OPERATION ARE REGULATED BY THIS CODE, SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORD WITH APPROVED PLANS AND SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN ACCORD WITH APPROVED PLANS AND SPECIFICATIONS. 2. OPERATION AND MAINTENANCE MANUALS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE, EXCEPT EQUIPMENT NOT FURNISHED AS PART OF THE PROJECT. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY IDENTIFIED. 3. NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY. 4. HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION, INCLUDING WIRING DIAGRAMS, SCHEMATICS, AND CONTROL SEQUENCE DESCRIPTIONS. DESIRED OR FIELD DETERMINED SET POINTS SHALL BE PERMANENTLY RECORDED ON CONTROL DRAWINGS AT CONTROL DEVICES, OR, FOR DIGITAL CONTROL SYSTEMS, IN PROGRAMMING COMMENTS. DRAWING NOTES SHALL REQUIRE COMMISSIONING IN ACCORDANCE WITH SECTION1416 . DRAWING NOTES MAY REFER TO SPECIFICATIONS FOR FURTHER COMMISSIONING REQUIREMENTS. PLANS AND SPECIFICATIONS SHALL REQUIRE TESTS MANDATED BY THIS SECTION BE PERFORMED AND THE RESULTS RECORDED. PLANS AND SPECIFICATIONS SHALL REQUIRE PREPARATION OF PRELIMINARY AND FINAL REPORTS OF TEST PROCEDURES AND RESULTS AS DESCRIBED IN SECTION 1416.2.3. PLANS AND SPECIFICATIONS SHALL IDENTIFY THE FOLLOWING FOR EACH TEST: 5. A COMPLETE NARRATIVE OF HOW EACH SYSTEM IS INTENDED TO OPERATE INCLUDING SUGGESTED SET POINTS. VAV # MARK WC -1 LAV - 1 MS - 1 FD -1 DF -1 TP -1 WCO -1 WHA -1 MANUFACTURER TITUS DESCRIPTION WATER CLOSET- AMERICAN STANDARD INSTALL FLUSH VALVE ON OPEN SIDE OF WATER CLOSET LAVATORY MOP SINK FLOOR DRAIN DRINKING FOUNTAIN TRAP PRIMER WALL CLEAN OUT WATER HAMMER ARRESTOR ELECTRIC WATER HEATER NOTE: INSTALL ALL PLUMBING FIXTURES TO BE FULLY ACCESSIBLE TO INDIVIDUALS WITH DISABILITIES IN ACCORDANCE WITH THE AMERICANS WITH DISABILITIES ACT OF 1990 (ARCHITECTURAL GUIDELINES). FIXTURES AND THEIR INSTALLATION SHALL ALSO COMPLY WITH AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) PUBLICATION A117.1 - 'PROVIDING ACCESSIBILITY AND USABILITY FOR PHYSICALLY HANDICAPPED PEOPLE' AND /OR GOVERNING CODES. - ALL PLUMBING FIXTURES EQUIPMENT, TRIM, & FITTINGS SHALL COMPLY WITH LOCAL, STATE, AND FEDERAL REGULATIONS AND CODES, INCLUDING, BUT NOT LIMITED TO, WATER AND ENERGY CONSERVATION CODES. THE SCHEDULED AND /OR SPECIFIED PLUMBING FIXTURES AND EQUIPMENT REPRESENT THE MINIMUM CRITERIA AND SHALL BE THE BASIS FOR THE CONTRACTOR'S BASE BID. IF THE SCHEDULED OR SPECIFIED FIXTURES OR EQUIPMENT DO NOT COMPLY WITH GOVERNING CODES OR REGULATIONS IN ALL RESPECTS, THE CONTRACTOR SHALL PROVIDE AN ALTERNATE BID FOR COMPLYING FIXTURES, EQUIPMENT, TRIM, OR FITTINGS. THE ABSENCE OF AN ALTERNATE BID SHALL BE CONSTRUED TO MEAN THAT THE CONTRACTOR'S BID INCLUDES ALL COSTS NECESSA MEET ALL REGULATIONS & CODES. ALL PIPING BELOW LAVATORY SHALL BE INSULATED WITH TRUEBRO LAV GUARDS AND CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORY. \ MP2 G.C. TO PROVIDE REFLECTIVE TAPE MODEL TQP MANUFACTURER AMERICAN STANDARD FIAT ZURN OASIS PRESICION PLUMBING PRODUCTS, INC. ZURN SIOUX CHIEF A.O. SMITH INSULATED ROUND DUCT UNIT SIZE - TO SUPPLY AIR MAIN FLEXIBLE CONNECTION (MAX. 5ft.) SCALE = N.T.S. r _ 1 Skin Loads Lighting Equipment People Partition Cool. Prot. HeaL Prat cod vent. Heat Vent. Coot. Inhl. Heat, Infil. Draw Thru Fan Elow•Thru Fan Reserve Cap Reheat Cap Supply Duct Return Duct MIsc. Supply Misc. Return 9u0ding Totals 7,544 3,000 28 • ventilation NFikration Pretreated An Zone Loads Plenum Loads Fan & Duct Loads Balloting Totals 0 ' Total Budding Supply Air (ba ed on a 17' TD) Total Building Vent Fly CO 00% of Supply): Total Conditioned Atr Space Supply Alr Per Unit Nea' Area Per Cooling Capacity Gaoling Capacity Per Area Healing Capacity Per Ater Total Heeling Required Wllh Outset* N• Total Coding Required Wrth Outside Fir INLET (IN.) 16 WASTE FIXTURE CO VENT MODEL "CADET" #2377.100 "COMRADE" #0124.024 MSB -2424 Z -415 PACSL HI /LOW P2 -500 Z -1441 653 -B DEL -6 SUPPLY AIR DIFFUSER 1 DIFFUSER MOUNTING SCHEMATIC �MP2 / SCALE = N.T.S. CI, F R II etefI' A4es1 Cdeulatm", Pram:arn LPw 0 rppr.4isn Uhf 0 ' 3.4 J 110'32 Buitdino Summary Loads Building peaks In September at 11pm Roof 0 000 Wall 0 0.00 Glass 0 0.00 Floor Slab 0 000 VACUUM RELIEF VOLUME DAMPER VALVE WATTS 36A ffi* 0d aura BaFi 1 0.00 0,00 0.00 0.00 0,00 000 0 00 1 0.00 0.00 0.00 0.00 0,00 0.00 000 0.00 0.00 0.00 0.00 0.00 0 00 0.00 0.00 0,00 0.00 0.00 0.00 3" 1 -1/2" yr 1 -1/2" STRAP CLAMP (TYPICAL) 28.09 10.95 5,544 7.41 0,00 5.544 48,45 dsU ._ 0 0 5,544 46,456 0 0 0 5,544 4 6,458 2,500 CFM 0 CFM 0,155 Sq.H 07899 CFM/SCI.0 720 3 Sq ft/Ton 00014 Tons/&g 000 Btuh/Sq.ft 0 Btuh 4.33 Tons PLASTER FRAME mn E8y'3alnyan 46 !!arrk, 0 FAN POWERED, PARALLEL FLOW TERMINAL UNIT SCHEDULE 2" 1 -1/2" 2" 1 -1/2" DRYWALL CEILING 20,09 10,95 12,95 No wet C.n ❑ 0.00 0.00 0.00 0.00 0.00 52,003 100.00 0 52,003 0 52,003 54,02 21,08 24.92 0.00 0.00 0.00 0.0❑ 0 00 0.00 0.00 0.00 000 0.00 0.00 0 00 0.00 0.00 0.00 0.00 000 0.00 100.00 0 00 0 00 100.00 rnna/ rrrnrary 15:X''9 01 Of PIA HVAC BUILDING LOAD SUMMARY PLUMBING FIXTURE SCHEDULE NNECTIONS CW HW 1/2" 1/2" 3/4" 1/2" 1/2" 3/4" 3/4" 1/2" 3/4 3/4" Y MIN SUPPLY CFM 950 • ELECTRIC HEATER KW 10 VOLTS /PH /HZ 460/3/60 REMARKS MCA 14 MOCP 20 ACCESSORIES 10 KW ELECTRIC HEATER 1.6 GAL PER FLUSH, FLOOR MOUNTED, ELONGATED BOWL, TANK TYPE, CHROME TRIP LEVER, WATER SAVER, VITREOUS CHINA. MEETS ADA AND ANSI REQUIREMENTS WHEN INSTALLED WITH TOP OF SEAT BETWEEN 17" AND 19 ". FURNISH WITH WHITE AMERICAN STANDARD MODEL #5325.024 OPEN FRONT SEAT WITH COVER AND CHROME SUPPLY STOPS. EQUALS BY KOHLER OR CRANE. PROVIDE WITH AMERICAN STANDARD FAUCET "RELIANT" MODEL #2385.0000 WITH POLISHED CHROME FINISH. EQUALS BY KOHLER OR CRANE. MOLDED STONE WITH VINYL BUMPERGUARD. FURNISH WITH AMERICAN STANDARD "COMMERCIAL" MODEL #8344.112 EXPOSED YOKE WALL MOUNT UTILITY FAUCET, TOP BRACE, VACUUM BREAKER, STOPS IN SHANKS, METAL LEVER HANDLES, 6" THREADED SPOUT AND 1/2" NPT FEMALE INLETS. 3" PIPE SIZE WITH TYPE "B" POLISHED NICKEL BRONZE STRAINER AND TRAP PRIMER CONNECTION. EQUALS BY JAY R. SMITH OR WADE. WALL MOUNTED. FURNISH WITH WALL HANGER PLATE, CHROME P -TRAP AND SUPPLY STOP. MOUNT TO ANSI STANDARD FOR HANDICAPPED AT 34 1/2" MAX. FROM FLOOR TO SPOUT OUTLET. ADJUSTABLE FLOW RATE, INTEGRAL VACUUM BREAKER AND INTEGRAL BACKFLOW PREVENTER. MOUNT IN AN ACCESSIBLE LOCATION PER MANUFACTURER'S PRINTED INSTRUCTIONS. PROVIDE WITH TRAP PRIMER DISTRIBUTION UNIT - PRECISION PLUMBING PRODUCTS INC., MODEL #DU -2. SIZE PER PIPING LATERAL, 4" MAX. DURA COATED CAST IRON BODY, WITH GAS WATERTIGHT APS TAPERED PLUG, AND ROUND SMOOTH STAINLESS STEEL ACCESS COVER WITH SECURING SCREW. EQUAL BY PRECISION PLUMBING PRODUCTS, INC. ENERGY SAVER LOWBOY, ELECTRIC WITH GLASS LINED TANK, 6 GALLON, 1,500 W., 120V/1 PH. EQUALS BY RHEEM OR RUUD. PROVIDE HW EXPANSION TANK AMTROL #S7 -12 WHERE REQUIRED BY CODE. 3/4" CW 3/4" HW APPROVED 4" DEEP DRAIN PAN SET ON PLYWOOD PLATFORM R -10 INSULATION UNDER TANK - OcC 3/4" PLYWOOD NOTE: PROVIDE ADEQUATE WALL BRACING TO SUPPORT WATER HEATER & PLATFORM MOUNT WATER HEATER ABOVE FINISHED CEILING. SCALE = N.T.S. SD DIELECTRIC UNION DUCT SMOKE DETECTOR REMOTE SENSOR THERMOSTAT THERMOSTAT AND SUBBASE e EQUIPMENT DESIGNATION 0 KEYED NOTES WH-1 NOTE: SET TEMP. @ 110°F 18 GA. 2" WIDE METAL STRAP WATER HEATER DETAIL 1 1/2" x 1 1/2" x 1/8" STEEL ANGLE FRAME OF ALL WELDED CONSTRUCTION PRIME AND PAINT WHITE. SECURE TO WALL WITH STEEL FASTENERS. 1" DRAIN LINE FROM DRAIN PAN. RUN DRAIN LINE TIGHT TO WALL AND TERMINATE IN MOP SINK. PROVIDE AIR GAP AS REQUIRED BY CODE, THERMOSTAT SET POINTS MODE COOLING HEATING OCCUPIED 75°F 66° F UNOCCUPIED 85° F 55°F THERMOSTATS FOR HEATING AND COOLING SHALL HAVE SET RANGE OF 55° F TO 85°F ADJUSTABLE TO PROVIDE A RANGE OF 10° F BETWEEN FULL HEATING AND FULL COOLING. ALL HEATING AND COOLING THERMOSTATS SHALL BE DESIGNED TO TERMINATE ALL HEATING AT 68° F AND ALL COOLING AT 75° F HVAC EQUIPMENT SHALL COMPLY WITH GOVERNING ENERGY CODE, THERMOSTATIC CONTROLS SHALL BE CAPABLE OF A DEADBAND OF AT LEAST 5°F. SYMBOLS LEGEND T & P RELIEF VALVE (FACTORY INSTALLED) WITH FULL SIZE DRAIN LINE. RUN RELIEF LINE TIGHT TO WALL AND TERMINATE IN MOP SINK. PROVIDE AIR GAP AS REQUIRED BY CODE. R X v s uirAiq C ity Of Tukwila PF .. FEB 2 2 2U08 REVISION NUMBER POINT OF CONNECTION BETWEEN NEW AND EXISTING PIPING (IF APPLICABLE) VOLUME DAMPER SUPPLY AIR DEVICE RETURN OR EXHAUST AIR DEVICE Ph. 314. 821. 1100 Fax 314. 821. 4162 Email chicos @cascocorp.com - P2),LTM ref i i I "\J ) /ill 1 11 C. 1 t1 1 / 1 t date comet project # drawn br checked by scale II'Yvl i n I Ih. LIC. #C0018394 EXPIRES 07/21/09 HVAC Sc PLUMBING SCHEDULES & DETAILS ;i07l;ss DES F.1 N As irtrlit•rti ed 02.01.08 LANDLORD AND OWNER i\A\ WHITE BLACK 02.21.08 PERMIT, LANDLORD & OWNER - ID • t=i L_ HOUSE MARKET _ „ " ww1 7: 1 J r 556 SOUTHCENTER :.;41 0 0 4=6 7 .F.'; STORE #3240 SEATTLE WA 98188 • rev. date re‘•ision descriptions