Loading...
HomeMy WebLinkAboutPermit PG08-098 - WESTFIELD SOUTHCENTER MALL - KUDO BEANSKUDO BEANS 2600 SOUTHCENTER MALL PG08-098 Parcel No.: 6364200010 Address: Suite No: Cityif Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT 2600 SOUTHCENTER MALL TUKW Permit Number: Issue Date: Permit Expires On: PG08 -098 06/09/2008 12/06/2008 Tenant: Name: Address: Owner: Name: Address: KUDO BEANS 2600 SOUTHCENTER MALL FC -14 , TUKVVILA WA WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA Contact Person: Name: RYAN O'NAN Address: 633 SOUTHCENTER MALL FC -14 , TUKWILA WA Contractor: Name: WOODBURN CONSTRUCTION Address: PO BOX 129 , WOODBURN OR Contractor License No: WOODBC *201PL Phone: Phone: 626 - 216 -6156 Phone: 503 - 981 -9504 Expiration Date: 11/02/2009 DESCRIPTION OF WORK: PLUMBING SYSTEMS FOR FOOD COURT KIOSK Value of Plumbing /Gas Piping: Fees Collected: $10,000.00 $241.00 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND QUANTITY Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 0 Water heater and/or vent 1 0 Industrial waste treatment interceptor, including 1 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and/or water 0 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 0 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 1 0 Medical gas piping (6 +) inlets /outlets 1 6 Gas Piping 0 Gas piping outlets (0 -5) 0 0 Gas piping outlets (6 +) 0 * *continued on next page ** doc: UPC -10/06 PG08 -098 Printed: 06 -09 -2008 City ("Tukwila ement of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http://www.ci.tulcwilawa.us Permit Number: PG08 -098 Issue Date: 06/09/2008 Permit Expires On: 12/06/2008 Permit Center Authorized Signature: -�L Date: (01-‘t-00 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this plumbing /gas piping permit. Signature: Print Name: Date: li " /`- ' O=e/ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -10/06 PG08 -098 Printed: 06-09 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 2600 SOUTHCENTER MALL TUKW KUDO BEANS Permit Number: Status: Applied Date: Issue Date: PG08 -098 ISSUED 03/28/2008 06/09/2008 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 12: ** *PUBLIC WORKS DEPARTMENT CONDITIONS * ** 13: Grease waste line shall connect to the ouside grease interceptor furnished by the mall. * *continued on next page ** doc: Cond -10/06 PG08 -098 Printed: 06-09 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: defiee finny /9GG Date: doc: Cond -10/06 PG08 -098 Printed: 06-09 -2008 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.Wa.us Building Permit No IND -15 B Mechanical Permit No. Plumbing /Gas Permit No. 1360 •-Q q9 Public Works Permit No. Project No. Fate) - 011 (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.; _ 636420 -0010 Site Address: 2600 Southcenter Mall, Space #FC -14 Tukwila, WA 98188 Tenant Name: Property Owners Name: Seong H. Kim Mailing Address: 2340 - 130th Avenue NE, D #150 Kudo Beans Suite Number: New Tenant: Floor: Yes ❑ ..No Bellevue; City WA 98005 State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: Ryan O'nan Mailing Address: E -Mail Address: 633 Southcenter Mall, Trailer #3 Day Telephone: (626) 216 -6156 Tukwila, WA 98188 ronan @us.westfield.com City State Zip Fax Number: GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for:Plumbing and Gas Piping (pg 5)) Company Name: TBD - TO BE FINALIZED BEFORE PERMIT IS PICKED UP Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: ARCHI•TECT OF RECORD — All plans, must bewet stamped by Architect of Record Company Name: Arai Jackson Ellison Murakami Mailing Address: 2300 7th Avenue Seattle, Contact Person: Yuko Kunugi E -Mail Address: ykunugi @araijackson.com WA 98121 City State Zip Day Telephone: (206) 323 -8800 Fax Number: (206) 323-8518 ENGINEER OF 1 ECO 2D — Alhplatis must be wet stamped by, Engmeer„of Record Company Name: Mailing Address: Contact Person: E -Mail Address: N/A Q:\Applications\Forms- Applications On LineO -2006 - Permit Application.doc Revised: 9 -2006 bh City State Zip Day Telephone: Fax Number: Page 1 of 6 • 4� PLUMBING AND GAS PIPING PERMIT INFORIVIATION -- 206- 431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mr Tp b e Z e n Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ /® 0 G d Valuation of Gas Piping work (contractor's bid price): $ Sco e of Work (please provide detailed information): 114 o- 1- b,l 1 Building Use (per Intl Building Code): Occupancy (per Intl Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Wash fountain Qty Fixture Type: Gas piping outlets _ Qty Bathtub or combination bath /shower Drinking fountain or water cooler (per head) Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks c Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer sewer Rain water system — per drain (inside building) Water heater and/or vent % Additional medical gas inlets /outlets — six or more _park Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors _ Repair or alteration of water piping and/or water treating equipment / Repair or alteration of drainage or vent piping I ! Medical gas piping system serving one to five inlets/outlets for specific gas Q:\Applications'P'orms- Applications On Line'3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 5 of 6 • PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW»J R AUTHOR' D AGENT: Signature: //7".4..j, Print Name: 412113 Ls /7,7,01;7. Mailing Address: '9Zt A/2„p1_ p I, ermfrt -,s' j Ale Date: x "' 2 2' Day Telephone: 73Z — 5 99e 6":" 7 z_ City State Zip Date Application Accepted: &- Date Application Expires: - o Staff Initials: Q`.Wpplications\Forms- Applications On Line \32006 - Permit Application.doc Revised: 9 -2006 bh Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: PG08 -098 Address: 2600 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 03/28/2008 Applicant: KUDO BEANS Issue Date: Receipt No.: R08 -02027 Payment Amount: $560.00 Initials: BLH Payment Date: 06/09/2008 12:07 PM User ID: ADMIN Balance: $0.00 Payee: WOODBURN CONSTRUCTION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 2707 560.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES PLUMBING - NONRES 000/345.830 360.00 000.322.103.00.0 200.00 Total: $560.00 3881 06/20 9711 TOTAL 2554.50 doc: Receiot -06 Printed: 06-09 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: PG08 -098 Address: 2600 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 03/28/2008 Applicant: KUDO BEANS Issue Date: Receipt No.: R08 -00962 Payment Amount: $41.00 Initials: WER Payment Date: 03/28/2008 02:38 PM User ID: 1655 Balance: $200.00 Payee: RYAN O'NAN TRANSACTION LIST: Type Method Descriptio Amount Payment Cash 41.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000/345.830 41.00 Total: $41.00 0528 03/28 $711 TOTAL 143.50 doc: Receiot -06 Printed: 03 -28 -2008 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION IR.. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 3 Project: (t 7 (e)o 6 fAA.) S Type of Inspection: ' I-- 1,v A Date Called: \J Address: z &oO wlA11 Special Instructions: Date Wanted: 7 _ Z c{ QE a. p. j Requester: Phone No: Ke/i "i.r Cvd., ® Approved per applicable codes. Corrections required prior to approval. COMMENTS: p Y�f,r r!f' �[,/ n (r �*S1,I !'/ C+R 17A( FlGw- T {-1, : k(# Kitt,- 0ti 1/705/ Ke/i "i.r Cvd., �,1 Q (r.,,,.%,, 1 Inspector: Date: 74g—Pr $60.00 Rf�FLSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit 17170 119 PERMIT NO. h CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project Type of Inspection: L Address: 2.G f Date Called: Special Instructions: Date Wanted: / v Requester: Phone No: 5-0 ?V 34,33 0 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Date: El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 1 INSPECTION NO. INSPECTION RECORD Retain a copy with permit oge PERMIT NO. CITY OF TUKWILA BUILDING DIVISION F. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Type o InspectiPPn: . o !c Address: ' c) in 4- i I Date Called: Special Instructions: Date Wanted: j a.m. Requester: ‘!h 1..11 5 74 rc ,...41 f a Leci PhomNo: %,v3-- 75'3 - ?(33 (( 0 Approved per applicable codes. El Corrections required prior to approval. cOM TS: 0.✓ v o !c j — i e 4I ‘!h 1..11 5 74 rc ,...41 f a Leci 14nn 1" t i+r/ (( (/4 ,rZr Ore Aki rich-t Date: ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: ti BACKFLOW PREVENTION ASSEMBLY TEST_ REPORT 6 ACCOUNT # NAME OF PREMISE 6tid .Ltr `3 �%� G2 /„.--"'efiefr Commercial ❑ Residential ❑ SERVICE ADDRESS _ _v d , e G4% /fl-toft, - CITY /-d- iti ZIP eMLFF CONTACT PERSON LJe i",f t/Aipi''. "�'trHONE (6--a.1) 745- 8' FAX ( ) LOCATION OF ASSEMBLY £ z-r-e I ce ef,®3ei DOWNSTREAM PROCESS 40 c.TGC 4.0 L4S ✓ NEW INSTALLXISTING ❑ REPLACEMENT ❑ OLD SER. # MAKE OF ASSEMBLY DCVA ❑ RPBA lid' PVBA ❑ OTHER PROPER INSTALLATION? YES 2110 ❑ 5 MODEL 4/6? SERIAL NO. #;;Io 3 c7 l0 P SIZE ? N INITIAL TEST PASSED DCVA / RPBA DCVA / RPBA RPBA PVBA /SVBA CHECK VALVE NO.1 CHECK VALVE NO.2 OPENED AT 2'Y PSID AIR INLET OPENED AT PSID , #1 CHECK e--- Z,PSID EAKED • O / O PSIDQ� LEAKED • DID NOT OPEN • AIR GAP OK? PSID FAILED • NEW PARTS AND REPAIRS CLEAN REPLACE PART CLEAN REPLACE PART CLEAN REPLACE PART CHECK VALVE HELD AT PSID • • • • • • • • LEAKED • • • • —_- • • CLEANED • • • • • • • REPAIRED • -- TEST AFTER REPAIRS OPENED AT PSID AIR INLET PSID LEAKED • PSID LEAKED • PSID #1 CHECK PSID CHK VALVE PSID PASSED • FAILED • AIR GAP INSPECTION: Required minimum air gap separation provided? Yes ❑ No ❑ Detector Meter Reading ,.LINE PRESSURE- 6Or PSI CONFINED SPACE? REMARKS: TESTERS SIGNATURE: CERT. NO. B5035 DATE 7,- 17--64.' TESTERS NAME PRINTED: _Kurt Muller TESTERS PHONE # ( 206) 396 -4391 REPAIRED BY: DATE FINAL TEST BY: CERT. NO. DATE CALIBRATION DATE 5 /14 /08 GAUGE # 06041259 MODEL 845 SERVICE RESTORED? YES ❑ NO ❑ I certify that this report is accurate, and I have used WAC 246 -290 -490 approved test methods and test equipment. Joanna Spencer - RE: Westfield tenants thook up to a grease trap and not toanout From: To: Date: Subject: interceptor grease interceptor Page 1 "Marcia Peddicord" <mpeddicord @us.westfield.com> "Joanna Spencer" <jspencer @ci.tukwila.wa.us> 04/04/2008 4:38 pm RE: Westfield tenants that hook up to a grease trap and not toanoutside grease Same situation although Kudo Beans would be connected to Landlord's grease waste vault serving the East side of the Food Court. Kudo Beans is not a "cooker ", so shouldn't generate very much grease, but will still have food prep. Marcia Peddicord Southcenter Expansion - Seattle 633 Southcenter, Trailer #3 Seattle, WA 98188 Phone: 206 - 802 -6071 Fax: 206 - 246 -7043 Cell: 818 -402 -8923 Personal Cell: 724 - 321 -6541 mpeddicord @westfield.com PERMANENT FILE COPS Original Message From: Joanna Spencer [mailto :jspencer @ci.tukwila.wa.us] Sent: Friday. April 04, 2008 4•30 PM To: Marcia Peddicord Subject: RE: Westfield tenants that hook up to a grease trap and not toanoutside grease interceptor Marcia: Thanks, this clarifies my concerns. How about KUDO BEANS @ FC -14 ? Joanna »> "Marcia Peddicord" <mpeddicord @us.westfield.com> 04/04/2008 4:28 pm »> Chicken Now, FC -11, is connecting to the line that runs to Landlord's grease waste vault that serves the west side Tenants of the Food Court and is exterior of the building. I have requested that list (who goes to which grease waste vaults) and should have it for you - hopefully - by next City meeting. But, as a rule, all Restaurants and all Food Court Tenants will connect to one of several grease waste vaults. Also, the Tenants on the east side close to JC Penney's (such as Starbucks 1047 and Auntie Anne's 1120) will be connected to their own Landlord provided grease waste vault. Only a few Tenants, who have very little to no grease, are in -line and not close to a connection point for the grease waste vaults (i.e. 555 Godiva, 546 Auntie Anne's and 856 Teavana) and possibly a few "wet kiosks" will have their own small "under the sink" interceptors. Joanna Spencer - RE: Westfield tenants took up to a grease trap and not toanoutiegrease interceptor Marcia Peddicord Southcenter Expansion - Seattle 633 Southcenter, Trailer #3 Seattle, WA 98188 Phone: 206 - 802 -6071 Fax: 206 - 246 -7043 Cell: 818- 402 -8923 Personal Cell: 724 - 321 -6541 mpeddicord @westfield.com Page 2 Original Message----- - From: Joanna Spencer [mailto :jspencer @ci.tukwila.wa.us] Sent: Friday, April 04, 2008 4:05 PM To: Marcia Peddicord Subject: Westfield tenants that hook up to a grease trap and not to anoutside grease interceptor Marcia: PW is reviewing CHICKEN NOW @ FC -11 plumbing permit PG08 -044. Application shows that they are connecting to the grease line which is connected to the grease trap provided by the landlord. Please confirm that they are hooking up to the grease trap and not to the outside grease interceptor. It would be helpful for us to get a list of "restaurant/tood serv. tenants" not hooking up to existing outside grease interceptor(s). Thanks for your cooperation. Joanna Spencer Development Engineer City of Tukwila Public Works Department 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 -2544 phone: 206 - 431 -2440 fax: 206 - 431 -3665 jspencer @ci.tukwila.wa.us • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG08 -098 DATE: 03 -28 -08 PROJECT NAME: KUDO BEANS SITE ADDRESS: 2600 SOUTHCENTER MALL FC -14 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Bu' • n Division Fire Prevention ❑ Planning Division Public W;p,�ks 'r! Structural ❑ Permit Coordinator t 04 r2 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: ' Incomplete DUE DATE: 04 -01-08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUESITHURS RO TING: Please Route Structural Review Required REVIEWER'S INITIALS: ❑ No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 04 -29 -08 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2-28-02 Look Up a Contractor, Electri or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. License Information License WOODBC *201 PL Licensee Name WOODBURN CONSTRUCTION CO. Licensee Type CONSTRUCTION CONTRACTOR UBI 600377351 Ind. Ins. Account Id #5 Business Type CORPORATION Address 1 PO BOX 129 Address 2 City WOODBURN County OUT OF STATE State OR Zip 97071 Phone 5039819504 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 10/13/1980 Expiration Date 11/2/2009 Suspend Date Separation Date Parent Company Previous License Next License WITHELC044OF Associated License Business Owner Information Name Role Effective Date Expiration Date WITHERS, TERRENCE C Cancel Date 01/01/1980 Bond Amount PARKER, WILLIAM E #5 01/01/1980 6358479 WITHERS, ROBERT L Until Cancelled 01/01/1980 0 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #5 SAFECO INS CO 6358479 10/25/2005 Until Cancelled $12,000.00 09/19/2005 Page 1 of 3 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= WOODBC *201PL 06/09/2008 TO BUILDING MAIN WATER SUPPLY PLUMBING DIAGRAM 3/8" = 1I-0" 0 1 2 3 4 5 NORTH LEGEND: WASTE SUPPLY WASTE LINE GREASE WASTE LINE COLD WATER HOT WATER FOt1 Oqei (E) MAIN WASTE LINE AND (E) 3" VENT PIPE CONNECTION BELOW FLOOR TO MAIN BUILDING SYSTEM (E) GREASE LINE CONNECTION BELOW FLOOR TO MAIN BUILDING SYSTEM, THEN TO (E) LANDLORD PROVIDED GREASE TAW SYSTEM l> L i WASTE PLUMBING DIAGRAM 3/8" = 0 1 2 3 4 5 NORTH PLUMBING PLAN NOTES 1. ALL SUPPLY, WASTE AND VENT PIPING ON THIS PLAN IS SHOWN AS A DIAGRAM AND CONTRACTORS SHALL INSTALL THEM IN ACCORDANCE WITH THE MOST CURRENT CODE PER LOCAL JURISDICTION. 2. SEE KITCHEN SHEETS FOR ADDITIONAL PLUMBING INFORMATION AT KITCHEN EQUIPMENT. V 14-14[- 1 3. GREASE LINE AND GREASES IS PROVIDED BY LANDLORD UNDER SEPARATE PERMIT. Permit No. By REVISIONS " hanpes shall be made to the scnpP , ,vithout prior approval of •l - t. kwi!a Building Division. 7 7: visions will require a new plan submittal r ; : ^v include additional plan revirw fees FILE COPY CS Date: City of Tuimila B DNIS1ON 'P6og -o98 hr ABATE PERMIT REQUIRED FOR: Mechanical Etectricai ❑ Plumbing ❑ Gas Piping City of Tukwila BUIL,= if f DIVISION REVIEWED FOR .h CODE COMPLIANCE APPROVED APR 1 2OgF Of Tukwila BUILDING DIVISION mar review approval is subject to errors and onions. Approval of construction documents does not authorize the violation of any adopted code or order. Receipt of approved Field Copy and conditions is a owdec ed: RECEIVED MAR 2 8 2008 PERMIT CENTER 0 arai jackson unison murakami LLP ARCHITECTURE I URBAN DESIGN I INTERIORS 2300 seventh avenue seattle, washington 98121 phone: 206.323.8800 fax: 206.323.8518 Internet: www.araijackson.com Kudo Beans coffee & tea Westfield Southcenter Mall 2600 Southcenter Mall, Space #FC-14 Tukwila, WA 98188 Owner Innovated Consulting LLC 928 Arnold Avenue Point Pleasant, NJ 08742 Telephone 732.899.8411 Architect ARAI JACKSON ELLISON MURAKAMI 2300 7th Avenue Seattle, WA 98121 Telephone 206.323.8800 Facsimile 206.323.8518 Food Supply & Dgn Bargreen Ellingson, INC. 3627 1st Avenue South Smite, WA 98134 Telephone 206.682.1472 Facsimile 206.682.2367 Electrical Engineering j Omega Engineering, Inc. 815 First Avenue, #333 Seattle, WA 98104 Telephone 206.682.1472 Facsimile 206.6822367 KEY PLAN MCISEN1fl REVISIONS No. Date PLUMBING DIAGRAMS Scale AS NOTED In Charge Drawn By 4393 2DC18008 REGISTERED l ARCHITECT I l STATE OF WASHINGTON Description RM Checked By JO Approved By A201 o CW -COLD WATER • HW -HOT WATER • CLOSED DRAIN - DIRECT WASTE FS 7 � W M REVISIONS # DATE I ? ?/ ? ? / ? ? ?? 2 3 4 5 6 DRAWN BY: M.TABOR PROJECT MANAGER C. ALLERS PROJECT NUMBER: SCALE: 1/4" =1' -0" SHEET TITLE: PLUMBING ROUGH -IN PLAN SHEET NUMBER K...4 4of4 o CW -COLD WATER • HW -HOT WATER • CLOSED DRAIN - DIRECT WASTE FS 12" X 12" FLOOR SINK - INDIRECT WASTE PLU V B I N G LEGE \D F6[02' Ot a pt 1. IT IS THE GENERAL CONTRACTORS RESPONSIBILITY TO SIZE, SUPPLY AND INSTALL A GREASE INTERCEPTOR /TRAP IF ONE IS REQUIRED. PLUv1Bl\ G OTES 3. THE PLUMBING CONNECTIONS, SPECIFICATIONS AND DIMENSIONS SHOWN ON THESE PLANS ARE FOR FOOD SERVICE EQUIPMENT ONLY. SEE ARCHITECTS PLAN SET FOR ALL OTHER PLUMBING REQUIREMENTS FOR THIS PROJECT. 4. ALL PLUMBING ROUGH -IN WORK AND FINAL CONNECT1OINS FOR ALL ITEMS SHOWN AND SPECIFIED ON THESE PLANS BY BARGREEN ELLINGSON SHALL BE PERFORMED BY THE PLUMBING CONTRACTOR. 5. THE PLUMBING CONTRACTOR SHALL PROVIDE AND INSTALLA11OIN MATERIAL ON ALL DRAIN LINES FROM ICE BINS, ICE PANS, ETC., SO AS TO ELMININATE CONDENSATION FORMATION. 6. UNLESS OTHERWISE SPECIFIED IN THESE PLANS OR OTHER WRITTEN CONTRACTS, IT SHALL BE THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR TO PROVIDE ALL PLUMBING -TYPE MATERIALS INCLUDING VALVES, TRAPS, TUNE STRAINERS, FLOOR SINK COVERS, PRESSURE REGULATORS, SIPHON BREAKERS, ETC. REVIEWED FOR CODE COMP APP OVE Opp ; C , , 7. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO VERIFY THAT THE LOCATIONS FOR ALL MECHANICAL REQUIREMENTS WHICH REQUIRE FLOOR PENETRATIONS DO NOT CONFLICT WITH STRUCTURAL MEMBERS IN THE FLOOR. 8. THE GENERAL CONTRACTOR SHALL SUPERVISE THE LOCATION OF ALL FLOOR DRAINS ON THE JOB SITE SO AS TO ENSURE THE BEST SLOPE POSSIBLE OF THE SURROUNDING FLOOR TO THESE DRAINS. 9. ALL DRAIN LINES FROM EQUIPMENT REQUIRING CONDENSATION REMOVAL SHALL BE RUN IN COPPER. 10. PLUMBING CONTRACTOR TO SUPPLY WATER PRESSURE REDUCING VALVE SET AT 20 PSI FOR EACH DISHWASHER AND GLASS WASHER. SE1 p312 5108 ?EIC*11 Z�ON t4 01 FA R CpN RECEIVED MAR 2008 PERMIT CENTER