Loading...
HomeMy WebLinkAboutPermit M09-088 - RPIItPI 3311 S 120 PL M09 -088 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: doc: IMC -10/06 1023049069 3311 S 120 PL TUKW RPI 3311 S 120 PL , TUKWILA WA SABEY CORPORATION 12201 TUKWILA INTL BLVD 4THFL , SEATTLE WA JENNY ATCHISON 727 KENYON ST , SEATTLE WA EVERGREEN REFRIGERATION LLC 727 S KENYON ST , SEATTLE WA Contractor License No: EVERGRL954R2 DESCRIPTION OF WORK: INSTALL (1) ROOFTOP EXHAUST FAN TO SERVE A PRINTING PRESS, (1) SINGLE PORT EXHAUSRT HOOD, DUCTWORK Value of Mechanical: $4,000.00 Type of Fire Protection: CROW Tukwila Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended/Wall/Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 0 Air Handling Unit <10,000 CFM 0 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 1 Incinerator: Domestic 0 Commercial/Industrial 0 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.lukwila.wa.us MECHANICAL PERMIT EQUIPMENT TYPE AND OUANTITY * * continued on next page ** M09 -088 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 -763 -1744 Phone: 206 763 -1744 Expiration Date: 01/06/2010 M09 -088 08/21/2009 02/17/2010 Fees Collected: $219.24 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 1 Printed: 08 -21 -2009 Permit Center Authorized Signature: Signature: Print Name: doc: IMC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this pe s.'t does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or t •e c= • •rk. I am authoriz d to sign and obtain this mechanical permit. )0,4 • Permit Number: M09 -088 Issue Date: 08/21/2009 Permit Expires On: 02/17/2010 Date: 8P Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M09 -088 Printed: 08 -21 -2009 Parcel No.: 1023049069 Address: 3311 S 120 PL TUKW Suite No: Tenant: RPI 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M09 -088 Status: ISSUED Applied Date: 07/14/2009 Issue Date: 08/21/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 * *continued on next page ** M09 -088 Printed: 08 -21 -2009 ® • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the perform • o •f work. Signature: (� Print Name: 1J �'\ t 610L doc: Cond -10/06 Date: d M09 -088 Printed: 08 -21 -2009 CITY OF TUKWIN Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Site Address: 3 311 S 133 -- Sf Tenant Name: 1 I C MAAA*0 Property Owners Name: s l Project No: MECHANICAL PERMIT APPLICATION comfier Mailing Address: I? t T - lei I tt-t1 i Ai`fIM B IVo( Tl, u' 1 it Cit CONTACT PERSON Who do we contact when your permit is ready to be issued Name: Mailing Address: E -Mail Address: � k1ikt/i S G vi 7 S Nxki &n SY � ulwyPiLvt.l xeark vac . fA wk MECHANICAL CONTRACTOR INFORMATION Company Name: Uvao Ytuk Ii 4Ali ltd h Mailing Address: 1 ? • h"'� ` St Contact Person: J kvi A atA/ i o K E -Mail Address: JJ)A e/ VAL/A Ite/4 V P. .0 1t'1 Contractor Registration Nunnber: E GtJ O H:\Applications \Forms - Applications On Line\2009 Applications \I -2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh Mechanical Permit No. V,O9 o g g S (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: 10 a 3 0 ' b 1 Suite Number: Floor: New Tenant: ❑ Yes R.. No W State _10 1 IYU Zip Day Telephone: R6(1)-103, 1111"l DIANU WA qe[0t City State Zip Fax Number: 04) ? 81 IAA /91611 City State Zip Day Telephone: a tn. 7193 . 17 411 Fax Number: as .7(03. 9381 Expiration Date: / i 1 ti I ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip ENGINEER OF RECORD Allplans must be wet stamped by Engineer of Record Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Page 1 of 2 Unit Type: Qty Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct TgteAkoo - FtrPut 1 Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat/Refrig/Cooling System In erator — Domestic Other Mechanical Equipment — F I Air Handling Unit <10,000 CFM Incinerator — Comm/Ind • 1 Valuation of Project (contractor's bid price): $ "f 1 ua° Scope of Work (please provide detailed information): l VAS 1111 Qi'* C ) 1117 fix' A- t t S al/ G. ri n i (1 YQ SE , � ix C 1) s� Pp � 6 r9 -ex �►.c.rtiS`f 8 0 ; d,ikr - W D IT - Use: Use: Residential: New ❑ Replacement ❑ Commercial: New ® Replacement ❑ Indicate type of mechanical work being installed and the quantity below: Signature: Print Name: BUILDING 0 O AUTHORIZED AGENT: (�S8 h � Mailing Address: 7a1 ?TA Sfi H:\Applications\Forms- Applications On Line \2009 Applications \I -2009 - Mechanical Permit Application.doc Revised: 1.2009 bh Fuel Type: Electric © Gas ❑ Other: PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date: 7'i Nl Day Telephone: 1:111/' 70. 17 S W* R 10 City State Zip I Date Application Accepted: - 7-1 1- f-O7 Date Application Expires: 1 - 1-i - Staff Initials: tt e t ' I Page 2 of 2 Parcel No.: 1023049069 Address: 3311 S 120 PL TUKW Suite No: Applicant: RPI Receipt No.: R09 -01083 • City of Tukwila Payee: EVERGREEN REFRIGERATION Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 003764 219.24 Authorization No. ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES RECEIPT Initials: WER Payment Date: 07/14/2009 10:38 AM User ID: 1655 Balance: $0.00 Account Code Current Pmts 000.322.102.00.0 175.39 000/345.830 43.85 Total: $219.24 Permit Number: M09 -088 Status: PENDING Applied Date: 07/14/2009 Issue Date: Payment Amount: $219.24 PAYM ENT RECEIVEIJ doc: Receiot -06 Printed: 07 -14 -2009 C�FM ENT.S: 1 I; Z A 01 ("' — ( .V (/ ( / L �- Date Called: ,- Z A\ V\ —1�+ 5 " 4.YJ Y VV''' ► -�/ a.m., m. Requester: b� Phone No: - Pro % (L / P hi Ad P ct, a_ Type of Inspection: t f .-- I Jul I Address: 2`5 .. L �- Date Called: ,- Special Instructions: Date Wartted: .- �(— Z� �' a a.m., m. Requester: Phone No: 1 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit V Approved per applicable codes. LJ Corrections required prior to approval. Inspects r: El: 0.00 id a R EINSPECTION FED REQUIRED. (p rior to inspection, fee Ifiust be 6300 Southcenter vd., Suite 10b Call to schedule reinspection. Receipt t No.: 'Date: Pr ct: / PS; Type of Inspection: 11 =+ ti1 ( Addr ss: i 331 l 5 1 2 v PL_._. Date Called: Special Instr I t ions: _.206 Date Wanted: (a.....;71. q — 2 3- aS .m,. Requester: Phone No: -co'7 - 3)57 INSPECTION RECORD Retain a copy with permit INSPECVION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Mb - 6 PERMIT NO. (206)431 -3670 COMMENTS: co Approved per applicable codes. Corrections required prior to approval. El $60.00 EINSPECTION EE RE ' MIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: c1 ?I Type of Inspection: F' - Address: X3 )1 S 12OPL- Date Called: Special Instructions: Date Wanted: Cj Z1— Ci m. Requester: Phone No: e 6 75 -3187 INSPECTION RECORD Retain a copy with permit ' / INSPECTION NO. PERMIT NC>✓ CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -360 Approved per applicable codes. Olt -00° Corrections required prior to approval. - COMMENTS: 0A kiCe1ie Inspector: Date: ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date i INCOMPLETE LTR # , Z FILE COPY STRUCTURAL PLAN AND NOTES FOR RPI VENT TUKWILA, WASHINGTON PREPARED FOR: EVERGREEN REFRIGERATION, LLC AUGUST 9, 2009 CASCADE CREST CONSULTING ENGINEERS. INC. 21902 96TH AVENUE SE SNOHOMISH, WASHINGTON 98296 (296) 909 -7808 PREPARED BY: KEITH MOORE, S.E. EXPIRES MOo 88 REVIEWED FOR CODE COMPLIANCE IAPP tV AUG 2 0 2009 RECEIVED AUG 122009 PERMIT CENTER City of Tukwila BUILDING DIVISION 33 - opEtal L- wor5 I3 -TA 0 FL+ 1Zeorror Ft. O 411-Ifi Z4 X a .c. CASCADE CROW CONSULTING Emanstanas. hGC. PROJECT: f� FE VELLT ENGR: DATE: se, 79 /09 SCALE: SHEET ] MIL io � C t-fG 4 12- 1I 33 - opEtal L- wor5 I3 -TA 0 FL+ 1Zeorror Ft. O 411-Ifi Z4 X a .c. CASCADE CROW CONSULTING Emanstanas. hGC. PROJECT: f� FE VELLT ENGR: DATE: se, 79 /09 SCALE: SHEET GENERAL STRUCTURAL NOTES: 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS AND THE INTERNATIONAL BUILDING CODE (IBC), LATEST EDITION. 2. DESIGN LOADING CRITERIA: ROOF LIVE LOAD 25 PSF MECHANICAL UNITS 340 POUNDS EARTHQUAKE , SDs = 0.90 3. STRUCTURAL SKETCH SHALL BE USED IN CONJUNCTION WITH MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ENGINEER OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. THE EXISTING CONDITIONS SHOWN ON THE DRAWINGS ARE BASED EITHER ON SITE OBSERVATION, ORIGINAL DRAWINGS OR WERE ASSUMED BASED ON EXPECTED CONDITIONS. IF THE EXISTING CONDITIONS DO NOT CLOSELY MATCH THE CONDITIONS SHOWN ON THE DRAWINGS, OR IF THE EXISTING MATERIALS ARE OF QUESTIONABLE OR SUBSTANDARD QUALITY, NOTIFY THE ENGINEER PRIOR TO COMMENCING ANY WORK. 5. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE DRAWINGS. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO COMPLETE THE WORK. 7. FRAMING LUMBER UTILIZED FOR SUPPORT OF THE MECHANICAL UNITS SHALL BE KILN DRIED OR MC -19, AND GRADED AND MARKED IN CONFORMANCE WITH W.C.L.B. STANDARD GRADING RULES FOR WEST COAST LUMBER NO. 17. 4X MEMBERS SHALL BE HEM -FIR NO. 1, MINIMUM BASIC DESIGN STRESS, Fb = 950 PSI, Fv = 150 PSI. IF BLOCKING IS EXPOSED TO THE WEATHER, IT SHALL BE PRESSURE - TREATED WITH COPPER AZOLE CA -B (HEM -FIR ONLY), OR ALKALINE COPPER QUAT (ACQ -C FOR DOUGLAS -FIR, OR ACQ -D FOR HEM -FIR) PRESERVATIVES UNLESS OTHERWISE NOTED. AMMONIACAL COPPER ZINC ARSENATE (ACZA) PRESERVATIVE, OR OTHER PRESERVATIVES WITH AMMONIA CARRIERS, SHALL NOT BE USED. 8. TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, AS SPECIFIED IN THEIR CATALOG NO. C- 2008. INSTALL NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY �3 MANUFACTURER. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. ALL TIMBER JOISTS AND MULTIPLE JOIST BEAMS SHALL BE CONNECTED TO FLUSH BEAMS WITH "HU" SERIES JOIST HANGERS, UNLESS OTHERWISE NOTED. 9. ALL TIMBER FASTENERS IN CONTACT WITH WOOD TREATED WITH ONE OF THE APPROVED PRESERVATIVE CHEMICALS LISTED IN THE NOTES ABOVE, OTHER THAN DOT SODIUM BORATE (SBX) WITHOUT NaSiO SHALL BE POST HOT DIP GALVANIZED PER ASTM A153 OR MECHANICALLY GALVANIZED PER ASTM B695, CLASS 55 OR GREATER. ALL FASTENERS EXPOSED TO THE WEATHER SHALL BE HOT DIP GALVANIZED PER ASTM A153. 10. CUT EXISTING 2X4 SUBPURLIN AS REQUIRED FOR NEW ROOF OPENING. CONNECT EXISTING 2X4 TO HEADER WITH LU24 HANGER. 11. NEW 2X4 HEADER WITH LU24 HANGERS. 12. SISTER NEW 2X4 MEMBERS TO THE SIDE OF THE EXISTING 2X4 SUBPURLINS WITH #8 WOOD SCREWS AT 12" ON- CENTER. 13. LUS24 -2 HANGER. 5/3 CC B EVERGREEN® R e f r i g e r a t i o n 727 SOUTH KENYON ST. • SEATTLE, WA 98108 (206) 763-1744 • FAX (206) 763 -2389 SUBJECT l EVIEWED FOR DE COMPLIANG APPROVED AUG 2 0 2009 City of Tukwila I ILDING DIVISION INCOMP LTR# ETE tioq 088 HVAC & Controls FILE COPY G Lv -LAM TO ext 1;l4wl LJi•' ATTN FAX DATE BY SCALE JOB P Vgr r EVER G R E E ® R e f r i g e r a t e 1r RICHARD BALDWIN richard@evergreenhvac.com CELL: (206) 679 -3172 ((206) 7 63.1744 Exr 233 1 -800- 475 -1744 FAX (206) 763 -2369 727 SOUTH KENYON Sr. • SEATTLE, WA 98108 571 5Pi2k(— TacovA.LS SHEET F __ I <0 X tf6/5T D UG7 Zc7 u � Ducr F-0(z. 14o-7001 $ - w► z ti 2><4/ Sri DESIGN - INSTALLATION - SERVICE RECEBVEP JUL 2 8 2009 PERMIT CENTEr- o on 33X3D gGk v T.0 a2.ovJJit '('(LA NS 't( °' () Design - Installation - Service r f- M09 -o88 INCOMPLETE LTR# Determination of Completeness Memo Date: July 16, 2009 Project Name: RPI Permit #: M09 -088 Plan Review: Allen Johannessen, Plans Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). N r�{If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, I / 'not copied.) 1. Provide details of the hood and show how the hood and ducts are seismically supported to the structure above. 2. Provide a framing detail for the duct penetrating the roof including a roof curb detail. d- heFe .b er y uestions concerning the above requirements, contact the Building Division at 206 - 431 -3670. I�EVIE '� ;• ® Rmments at this time. ODE C • MPLIANCE APPROVED AUG 2 0 2009 City of Tukwila UILDING DIVISION -Citsi 7-�e4, 2,0 c . c . 'T Y t 5 TokiboE ` L RM K waft -\&-g its 'Sf C FILE CUVY \u O. Tukwila Building Division Allen Johannessen, Plan Examiner RECEIVE JUL 2 8 2009 PERMIT CENTEF aE f- I �2 p u c,T f feoD 0 $ oPP B Y 5 Tor44 E 2hc to AT ReZECr 1 n.) 1 CONbENS)6 1► �� Ti Q ti01- .)1 v- 4i,n Cc) PDc, /1 ,- Date: 07/16/2009 To: EVERGREEN REFRIGERATION ATTN: JENNY Address: Coola;r Phone: Fax: Email: JENNY @EVERGREENHVAC.COM Project: RPI EXPANSION Location: SEATTLE, WA Engineer: From: Air Tec Co By: Erik Aploks Address: 85 South Orcas Phone: 206 - 763 -9911 Fax: 206 - 763 -1950 Email: eaploks @airtecco.com FILE COPY PArmit No. -- FAN SUBMITTAL COVER SHEET Page 1 of E Comments: INCOMPLETE LTR #� tel OcV 0 88 REVIEWED FOR CODE COMPLIANCE PPR VED AUG 2 0 2009 City of Tukwila BUILDING DIVISION RECEIVED JUL 2 8 2009 PERMIT CENTER RPI EXPANSION Fan Schedule 1 EXHAUST FAN 1 CRBA30MD8363 Belt 4,000 0.500 485 7.0 0.581 1 1/2 208/230/460V 3PH OPEN BDD PFC1 A/DA/D Accessory Key Item # Abbreviation Description 1 A/D 2 HP MOTOR SUPPLIED IN LIEU OF 1 1/2 HP 1 A/D DAMPER SIZE 32 X 32 1 BDD Gravity Damper 1 PFC1 Roof Curb NOTES: FanSelect Version 6 - July 2008 v6.12 Page 2of5 Sones LwA dBA @ 5' dBA @ 10' dBA @ 20' Octave Band Sound Power LwA) 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 7.0 66 54 48 42 74 73 66 64 60 54 47 40 Type CRBA Belt Drive Centrifugal Power Roof Ventilator AMERICAN COOLAIR CORPORATION Accessories A/D DAMPER SIZE 32 X 32 A/D 2 HP MOTOR SUPPLIED IN LIEU OF 1 1/2 HP BDD Gravity Damper PFC1 Roof Curb Notes: WEIGHT SHOWN BELOW INCLUDES ALL CRATING AND ACCESSORIES Weight: m I a O OUIT •o ooanot gr410/t1Kn• rranernoa•t 10. PROJECT LOCATION SUBMITTED BY APPROVED BY 435 lbs. Amencan Coolair Corporation certifies that the Type CRBA units shown herein are licensed to bear the AMCA seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA certified Ratings Program. (14 Ibs) NET (40 Ibs) WT a` 0.70 0.60 0.50 0.40 01 01 0.30 m 0.20 0.10 0.00 RPI EXPANSION SEATTLE, WA A B 40 l 50 1/4' 36 3/4 I TAG: EXHAUST FAN B DIA C Tip Speed: 3,889 ft/min 0 1,000 2.000 3.000 4.000 5 000 0.000 Volume Flow Rate (CFM) ENGINEER Dimensions in inches unless otherwise noted Outlet Velocity: 489 ft/min 7,000 C 2" 8 000 0.70 • Non- overloading aluminum wheel computer balanced • Force ventilated motor compartment isolated from airstream • Variable pitch motor pulley • Vibration isolators on drive frame • Weatherproof spun aluminum housing • NEMA Standard open drip -proof motors • Overlapping wheel /inlet venturi • Heavy duty self- aligning pillow - block bearings with cast iron housing • 1/2" galvanized mesh birdscreen • UL Listed for Standard 705 (most models) AMCA Licensed for Sound and Air Performance Power (BHP) excludes drives. Beanng losses are included. Performance ratings do not include the effects of y appurtenances in the airstream 0.40 Performance shown is for �• Installation Type 'N . Free inlet, Free outlet 0.30 = The sound ratings shown are loudness values in fan Bones at 5 It (1.5 m) in a hemispherical free 0.20 field calculated per AMCA Standard 301 Values shown are for Installation 0 10 Type 'A' : Free inlet tan sone levels Sound ratings apply to sones only 060 0.50 0 00 CONTRACTOR EVERGREEN REFRIGERATION DATE 7/16/2009 DATE FanSelect Version 6 - July 2008 v6.12 page 3 of 5 Fan Data 1 Motor Data Accessories Qty Model No. CFM inWg RPM BHP MHP RPM Voltage /Ph Hz Encl. BDD PFC1 A/DA/D 1 CRBA30MD8363 4,000 0.500 485 0.581 1 1/2 1,750 208/230/460V 3PH 60 OPEN Type CRBA Belt Drive Centrifugal Power Roof Ventilator AMERICAN COOLAIR CORPORATION Accessories A/D DAMPER SIZE 32 X 32 A/D 2 HP MOTOR SUPPLIED IN LIEU OF 1 1/2 HP BDD Gravity Damper PFC1 Roof Curb Notes: WEIGHT SHOWN BELOW INCLUDES ALL CRATING AND ACCESSORIES Weight: m I a O OUIT •o ooanot gr410/t1Kn• rranernoa•t 10. PROJECT LOCATION SUBMITTED BY APPROVED BY 435 lbs. Amencan Coolair Corporation certifies that the Type CRBA units shown herein are licensed to bear the AMCA seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA certified Ratings Program. (14 Ibs) NET (40 Ibs) WT a` 0.70 0.60 0.50 0.40 01 01 0.30 m 0.20 0.10 0.00 RPI EXPANSION SEATTLE, WA A B 40 l 50 1/4' 36 3/4 I TAG: EXHAUST FAN B DIA C Tip Speed: 3,889 ft/min 0 1,000 2.000 3.000 4.000 5 000 0.000 Volume Flow Rate (CFM) ENGINEER Dimensions in inches unless otherwise noted Outlet Velocity: 489 ft/min 7,000 C 2" 8 000 0.70 • Non- overloading aluminum wheel computer balanced • Force ventilated motor compartment isolated from airstream • Variable pitch motor pulley • Vibration isolators on drive frame • Weatherproof spun aluminum housing • NEMA Standard open drip -proof motors • Overlapping wheel /inlet venturi • Heavy duty self- aligning pillow - block bearings with cast iron housing • 1/2" galvanized mesh birdscreen • UL Listed for Standard 705 (most models) AMCA Licensed for Sound and Air Performance Power (BHP) excludes drives. Beanng losses are included. Performance ratings do not include the effects of y appurtenances in the airstream 0.40 Performance shown is for �• Installation Type 'N . Free inlet, Free outlet 0.30 = The sound ratings shown are loudness values in fan Bones at 5 It (1.5 m) in a hemispherical free 0.20 field calculated per AMCA Standard 301 Values shown are for Installation 0 10 Type 'A' : Free inlet tan sone levels Sound ratings apply to sones only 060 0.50 0 00 CONTRACTOR EVERGREEN REFRIGERATION DATE 7/16/2009 DATE FanSelect Version 6 - July 2008 v6.12 page 3 of 5 Unit Size Roof Curb and Damper Dimensions D E F G H J 06 -10 24 1/2 12 1/2 10 11 1 /4 16 1/2 13 1/4 12 -15 29 1/2 17 1/2 15 16 1/4 21 1 /2 18 1/4 16 -20 36 1/2 24 1/2 22 23 1/4 28 1/2 25 1/4 24 401/2_____28_1/2___ 25 1/2 id 32 1 /2 29 1/4 30 • 46 1/2 521/2 34 1/2 40 2 31 1 /2 33 1/4 38 1/2 44 1/2 35 1/4 41 1/4 391 4 44 62 1/2 50 1/2 47 1/2 49 1/4 54 1/2 51 1 /4 52 71 1/2 591/2 57 581/4 631/2 _ 601/4 ILG Roof Curb and Back Draft Damper Dimensions 1 8" STD. HEIGHT 1 INDUSTRIES DIVISION AMERICAN COOLAIR CORPORATION P.O. Box 2300 Jacksonville, Florida 32203 Phone: (904) 389-3646 Fax: (904) 387 -3449 • (904) 381 -7560 E -mail: fans @coolar.com Internet: www.coolair.com 1 5 /8 1 1 5 /8 D SQ. H O.D. J I.D. Dimensions in inches 1 THICK INSULATION raye U1 INDUSTRIES CRBA WEIGHTS AND DIMENSIONS Page 11 of 20 MODEL HP BOX / UPS / SIZE WGT. CUBIC CRATE TRUCK (INCHES) (LBS) FEET CRBA24H 1/3 CRATE TRUCK 49X49X47 259 CRBA24J 1/2 CRATE TRUCK 49X49X47 267 CRBA24K 3/4 CRATE TRUCK 49X49X47 270 CRBA24L 1 CRATE TRUCK 49X49X47 272 CRBA24M 11/2 CRATE TRUCK 49X49X47 281 CRBA24N 2 CRATE TRUCK 49X49X47 290 CRBA24P 3 CRATE TRUCK 49X49X47 330 CRBA30J 1/2 CRATE TRUCK 54X54X55 310 CRBA3OK 3/4 CRATE TRUCK 54X54X55 313 CRBA3OL 1 CRATE TRUCK 54X54X55 318 CRBA3OM 11/2 CRATE TRUCK 54X54X55 329 CRBA3ON 2 V CRATE TRUCK 54X54X55 334 CRBA3OP 3 CRATE TRUCK 54X54X55 355 CRBA3OQ 5 CRATE TRUCK 54X54X55 364 CRBA36K 3/4 CRATE TRUCK 68X68X64 412 CRBA36L 1 CRATE TRUCK 68X68X64 417 CRBA36M 11/2 CRATE TRUCK 68X68X64 421 CRBA36N 2 CRATE TRUCK 68X68X64 428 CRBA36P 3 CRATE TRUCK 68X68X64 446 CRBA36Q 5 CRATE TRUCK 68X68X64 461 CRBA36R 71/2 CRATE TRUCK 68X68X64 502 CRBA44L 1 CRATE TRUCK 72X72X69 519 CRBA44M 11/2 CRATE TRUCK 72X72X69 529 CRBA44N 2 CRATE TRUCK 72X72X69 540 CRBA44P 3 CRATE TRUCK 72X72X69 560 CRBA44Q 5 CRATE TRUCK 72X72X69 568 CRBA44R 71/2 CRATE TRUCK 72X72X69 607 CRBA52M 11/2 CRATE TRUCK 72X72X69 738 CRBA52N 2 CRATE TRUCK 86X86X73 742 CRBA52P 3 CRATE TRUCK 86X86X73 750 CRBA52Q 5 CRATE TRUCK 86X86X73 761 CRBA52R 71/2 CRATE TRUCK 86X86X73 789 CRBA52S 10 CRATE TRUCK 86X86X73 811 1 56 56 56 56 56 56 56 81 81 81 81 81 81 81 153 153 153 153 153 153 153 186 186 186 186 186 186 186 282 282 282 282 282 July 31, 2009 Jenny Atchison 727 S Kenyon St Seattle, WA 98108 RE: Letter of Incomplete Application # 2 Mechanical Permit Application M09 -088 RPI — 3311 S 120 PI Dear Ms. Atchison, This letter is to inform you that your resubmittal received at the City of Tukwila Permit Center on July 28, 2009 is determined to be incomplete. Before your application can continue the plan review process the following item from the following department needs to be addressed: Building Department: Allen Johannessen at 206 433 -7163 if you have any questions regarding the following memo: Please address the comment above in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenwer service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, fer M. shall P it Technician Enclosures File: M09 -088 • City of Tukwila Department of Community Development Jack Pace, Director W: \Permit Center \Incomplete Letters\2009 \M09 -088 Incomplete Ltr H2.DOC • Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 J Determination of Completeness Memo Date: July 30, 2009 Project Name: RPI Permit #: M09 -088 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen, Johanne`ssen, Plan Examiner. ` zr The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. The structural details provided indicate portions of the structural framing shall be altered to accommodate the new duct. A design for alterations to the structural roof framing shall be provided by a design professional or an engineer. As indicated in general note above, structural calculations and designs shall be originally signed and wet stamped by the design professional providing those drawings. Please provide a structural design by a design professional. Minimum size drawings shall be 11 x 17 ". Should there be questions concerning the above requirements, contact the Building Division at 206 - 431 -3670. No further comments at this time. July 16, 2009 Jenny Atchison 727 S Kenyon St Seattle, WA 98108 Dear Ms. Atchison, Sincerely, `CDIVAS Bill Rambo Permit Technician Enclosures File: M09 -038 • City of 7'CIJlIN1 Department of Community Development RE: Letter of Incomplete Application # 1 Mechanical Permit Application M09 -088 RPI — 3311 S 120 P1 If you have any questions, please contact me at the Permit Center at (206) 431 -3670. W:\Permit Center \Incomplete Letters\2009\1■I09 -088 Incomplete Ltr # 1.DOC wer Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you that your permit application received at the City of Tukwila Permit Center on July 14, 2009 is determined to be incomplete. Before your application can continue the plan review process the following item from the following department needs to be addressed: Building Department: Allen Johannessen at 206 433 -7163 if you have any questions regarding the following memo: Fire Department: Alan Metzler at 206 575 -4407 if you have any questions regarding the following: 1. What is the diameter of the duct? 2. Does duct exhaust flammable and /or combustible liquids? 3. Is the duct round or rectangular? Please address the comment above in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 0 Phone: 206 - 431 -3670 0 Fax: 206 - 431 -3665 • 1 Determination of Completeness Memo Date: July 16, 2009 Project Name: RPI Permit #: M09 -088 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Provide details of the hood and show how the hood and ducts are seismically supported to the structure above. 2. Provide a framing detail for the duct penetrating the roof including a roof curb detail. Should there be questions concerning the above requirements, contact the Building Division at 206 - 431 -3670. No further comments at this time. ACTIVITY NUMBER: M09 -088 DATE: 08 -12 -09 PROJECT NAME: RPI SITE ADDRESS: 3311 S 120 PL Original Plan Submittal X Response to Incomplete Letter # 2 Response to Correction Letter # Revision # After Permit Issued DEPARTN'ENTS: eritoq Building Division Public Works ❑ • PERMIT .. =: 5 i ' PLAN REVIEW /ROUTING SLIP Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ❑ Incomplete ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route n Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions n Notation: REVIEWER'S INITIALS: Documents /routing slip.doc 2 -28 -02 AA A 2 Ire Prevention In n Permit Coordinator DATE: Planning Division DUE DATE: 08 -13 -09 Not Applicable DUE DATE: 09-10-09 n Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DEPA THE TS: 1 Rir Bui ing ivislon Public Works ❑ Complete Documents /routing slip.doc 2 -28 -02 AE111 If • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M09 -088 PROJECT NAME: RPI SITE ADDRESS: 3311 S 120 PL Original Plan Submittal Response to Correction Letter # DATE: 07 -28 -09 X Response to Incomplete Letter # 1 Revision # After Permit Issued Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 07 -30-09 ❑ Incomplete APPROVALS OR CORRECTIONS: Approved n Approved with Conditions 11 Planning Division Permit Coordinator Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: on-(ht i►9 LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials:�17" TUES/THURS ROUTING: Please Route n Structural Review Required ❑ No further Review Required U REVIEWER'S INITIALS: DATE: n DUE DATE: 08 -27 -09 Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: • PLAN ACTIVITY NUMBER: M09 -088 PROJECT NAME: RPI SITE ADDRESS: 3311 S 120 PL X Original Plan Submittal Response to Correction Letter # DATE: 07 -14 -09 Response to Incomplete Letter # Revision # After Permit Issued DEPART ENT : 14"i le uilding ivision ► _� Complete Comments: Documents /routing slip.doc 2 -28 -02 Public Works ❑ Structural APPROVALS OR CORRECTIONS: • W /ROUTING SLIP /4Aik aevilak Fire Prevention 9.r DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n -0/ Planning Division Permit Coordinator DUE DATE: 07 -16 -09 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: 1— I v/ LETTER OF COMPLETENESS MAI.ED: Departments determined incomplete: Bldg Fire' Ping ❑ PW El Staff Initials: "�1� TUES/THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 08-13 -09 U Approved U Approved with Conditions 111 Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 412-(01 ® Response to Incomplete Letter # 2 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner • Project Name: RPI Project Address: 3311 S 120 P1 Contact Person: 1Z1c i . F f t - r , gA -1,w( Phone Number: 2 - 0 1 2 - 6 1 7 9 '3i72 Summary of Revision: Entered in Permits Plus on 8- 0_ \applications \forms - applications on Iine\revision submittal Created: 8-13-2004 Revised: Plan Check/Permit Number: M09-088 tAECEIVE° UP - 1UKVVRA 1 4 2009 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date o revision C Received at the City of Tukwila Permit Center by: 1 REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: ® Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: RPI Project Address: 3311 S 120 PI Contact Person: f- tce41 R 1 wJ Phone Number: - ZO 763 — 1 7 Summau of Revision: >F >E 1f? C /9-C- tfE. A 1 IJ F9 R-Nk A ?c Sheet Number(s): "Cloud" or highlight all areas of revision including date revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on City of Tukwila \applications \forms - applications on Tine \revision submittal Created: 8 -13 -2004 Revised: Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Plan Check/Permit Number: M09-088 Steven M. Mullet, Mayor Steve Lancaster, Director Fxr. Z REfEIlIED CITY OF TUKWILA IJUL 282009 at=. : (.1.3‘4: i• License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status EVERGHH910J0 EVERGREEN HOME HEATING Et ENGY CONSTRUCTION CONTRACTOR GENERAL UNUSED 4/20/2009 4/20/2011 ACTIVE EVERGI *201 D7 EVERGREEN REFRIGERATION INC CONSTRUCTION CONTRACTOR GENERAL UNUSED 3/27/1980 7/31/2006 REREGISTERED Name Role Effective Date Expiration Date EVERGREEN REFRIGERATION LLC PARTNER /MEMBER 12/22/2005 Look Up a Contractor, Electrici , Plumber or Elevator Professional Lice Detail Page 1 of 2 o Other Associated Licenses ® Business Owner Information Information in Spanish Topic Index I Contact Info i Home Safety Claims & Insurance Workplace Rights Trades & Licensing Find a Law (RCW) or Rule (WAC) Get a form or publication Return to List > Start a New Search > II Printer friendly General /Specialty Contractor A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Verify Workers' Comp Premium Status Name Phone No. Address Suite /Apt. City State EVERGREEN REFRIGERATION LLC (206) 763 -1744 727 S KENYON ST SEATTLE WA Zip 98108 County KING Business Type Limited Liability Company Parent Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 Check for Dept. of Revenue Account 602512953 ACTIVE EVERGRL954R2 CONSTRUCTION CONTRACTOR 1/6/2006 1/6/2010 ;+ GENERAL ...J UNUSED o Hide All https://fortress.wa.gov/lni/bbip/Detail.aspx I Search 0 Help 08/21/2009 COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER WA ENERGY CODE (WSEC) SECTION 1416.1. AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER PER WSEC SECTION 1416.2.4,1 ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCE REPORT SHALL BE PROVIDED TO THE OWNER PER WSEC SECTION 14516.2.2.1. FOR WAREHOUSES SEMIHEATED SPACES AND SIMPLE SYSTEMS AS DEFINED IN nS - C 0 .2 :"v Coy •+• ■. r :' T r' ADJUSTED, SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS, AND A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.2.3.2. FOR ALL OTHER SYSTEMS: HVAC CONTROL SYSTEMS SHALL BE TESTED, CALIBRATED AND ADJUSTED, SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS PER WSEC SECTION 1416.2.3.2; NECESSARY TESTS SHALL BE IDENTIFIED PER WSEC SECTION 1416.2.3; A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY PER WSEC SECTION, 1416.2.5.1 AND A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.2.5.2. EXHAUST FAN SCHEDULE MARK MANE. MODEL CFM S.P. VOLTS PHASE Hp /A NOTES EF 1 ILG CRBA 3000 0.5" 460 3 2 HP LOCATED ON ROOF i t lit ill Kii..51 727 SOUTH KENYON SEATTLE WASHINGTON 98108 206 763 - 1744 FAX 206 763 - 2389 3■1 = 0 , C- 0 0 , 0 CD 7° RPI • PROGRESS PRINTS — NOT FOR CONSTRUCTION DATE. 07/13/09 , > M o) 7 c:r) ' 7) 0 0 ' , m < F APPROVED FINAL DRAWINGS DATE: %) HVAC COVER SHEET IL.) 0 CONSTRUCTION DRAWINGS DATE: 1 o - , , , -- ' , :•\ j col , ; m Z 3311 S 120TH s C , ......), 1 , K O 0 AS BUILT DRAWINGS DATE: TUKWILA, WA 98169 , . rrr rri II ■ iii - - r -,„,, , „ oil N a N L =L[ 1 g N y II I SYMBOL LEGEND SYMBOL ABBV. DESCRIPTION `® DUCT SECTION SUPPLY DUCT SECTION - RETURN /EXHAUST r L RECTANGULAR DUCT ROUND DUCT FLEXIBLE DUCT L MVD MANUAL VOLUME DAMPER y BDD BDD BACKDRAFT DAMPER m MD MOTORIZED DAMPER FD FIRE DAMPER � - � FSD FIRE /SMOKE DAMPER (I20V POWER REQ.) CEILING RADIATION DAMPER SD SMOKE DETECTOR 11J T THERMOSTAT S SENSOR - - - -R R REFRIGERANT LINES - G _,..G G NATURAL GAS LINES 11 CEILING DIFFUSER (SUPPLY) to CEILING DIFFUSER (RETURN /EXHAUST) a EXHAUST FAN (CEILING MOUNTED) IGFI INLINE FAN RECEIVEP - U PROPELLER FAN . JUL 14 2009 I r SIDEWALL DIFFUSE I OWN fF L DUCT FITTING B.O.J. 1.2' 2' DATUM . WWI ail E - UNIT TAG DUCT RISER CINITY MAP :NO C FLO OR PLAN SCALE : 1/8" = 1 o O O SEPARATE PERMIT REQUIRED FOR: ©M anicai Iectrical O Plumbing ❑ Gas Piping City of Tukwila BUILDING DIVISION U SCOPE OF WORK O REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal -H r""!',, in,Ilide additional plan r+e ,rin ' e l fr [ REVIEWED FOR E COMPLIANCE Appnovro AUG 2 i 2000 A T . City of Tukwila 3 UILDING DIVISION FILE COPY Permit No Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt if approved Field d conditions Is : cknowledged• Date: ( 1 City of Tukwila BUILDING DIVISION DUCTWORK 1.1 GENERAL NOTES ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2" TO EACH DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 4 "TO EACH DIMENSION IF DUCTWORK IS ON THE EXTERIOR OF BUILDING. 1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND NUMBER IS THE HEIGHT. 1.3 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT RATING LESS THAN 50, PER IMC 602.2.1. 1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN 1/2 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT PRESSURES ABOVE 1/2 INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS -7. 1.5 ALL DUCT GAUGES PER SMACNA, IMC 603-4. 1.6 ALL DUCT SUPPORTS PER SMACNA, IMC 603 -10. 1.7 ATTACH DIFFUSERS AND GRILLES TO T -BAR GRID PER WA STATE & LOCAL CODES. 1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. INSULATION 2.1 INSULATE OR LINE DUCTWORK PER WA. STATE ENERGY AND MECHANICAL CODES. 2.2 INSULATE REFRIGERANT & CONDENSATE PIPING PER STATE & LOCAL ENERGY CODES. GENERAL CON1 °RACTOR 3.1 GENERAL CONTRACTOR TO PROVIDE AND CUT OPENINGS FOR ALL ROOFTOP, CEILING, FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING AND FIRE PROOF LINING PER IMC & IBC. 3.2 GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATION AND DIMENSIONS WITH ERL BEFORE FRAMING OPENINGS. 3.3 GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING AS REQUIRED FOR MECHANICAL WORK. 3.4 GENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS REQUIRED FOR MECHANICAL WORK. 3.5 GENERAL CONTRACTOR TO PROVIDE ADEQUATE ENGINEERING AS REQUIRED FOR MECHANICAL WORK. 3.6 GENERAL COf ITRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL EQUIPMENT, 3.7 GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY ERL PROVIDE ALL CANT STRIPS AND CURB INSULATION, AND SEAL AGAINST LEAKS. 3.8 GENERAL CONTRACTOR TO PROVIDE ALL CUTTING AND PATCHING OF T -BAR CEILING AS REQUIRED FOR HVAC INSTALLATION. 3.9 GENERAL CONTRACTOR TO PROTECT ALL OPENINGS THROUGH FLOORS PROVIDED FOR DUCTWORK INSTALLATION IN ACCORDANCE WITH TABLE 601 OF INTERNATIONAL BUILDING CODE, WHERE REQUIRED BY SECTION 707 OF IBC. ELECTRICAL 4.1 ERL TO INSTALL ALL LOW VOLTAGE CONTROL WIRING, CONDUIT WILL BE PROVIDED BY ELECTRICAL CONTRACTOR. 4.2 ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS, AND STARTERS FOR MECHANICAL EQUIPMENT. 4.3 ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS WITH ERL MECHANICAL PLAN AND WITH FIELD CONDITIONS. 4.4 ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH. 4.5 ERL TO PROVIDE 7 -DAY NIGHT SETBACK, PROGRAMMABLE TYPE T -STAT WITH CAPABILITY OF 5 °F DEADBAND. 4.6 ERL TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER. 4.7 ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL GCFI OUTLET WITHIN 25 FT OF EACH PIECE OF MECHANICAL EQUIPMENT. PLUMBING 5.1 PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL GAS PIPING FOR MECHANICAL EQUIPMENT PER CODE. 5.2 PLUMBING CONTRACTOR OFFSET VENTS 10 FEET MINIMUM FROM ALL HVAC FRESH AIR INTAKES OR 2' ABOVE HIGHEST POINT OF INTAKE, IMC 401.5.1. 5.3 CONDENSATE DRAINS FROM RTU BY ERI TO DRAIN WITHIN 12" OF UNIT. CONDENSATE DRAINS FOR AIR HANDLERS BY PLUMBER. ENERGY CODE COMPLIANCE 6.1 AT A MINIMUM, EACH FLOOR IS TO BE CONSIDERED A SEPARATE ZONE, VERIFY THERMOSTATIC CONTROL FOR EACH ZONE AS INDICATED ON PLANS. 6.2 OUTSIDE AIR INTAKES, EXHAUST OUTLETS, AND RELIEF OUTLETS SERVING CONDITIONEC' SPACES SHALL BE EQUIPPED WITH DAMPERS WHICH CLOSE AUTOMATICALLY WHEN THE SYSTEM IS OFF OR UPON POWER FAILURE, PER WSEC SEC. 1412.4.1. 6.3 AIR ECONOMIZERS WHERE REQUIRED BY CODE ARE INDICATED BY THE EQUIPMENT SCHEDULE AT 100% CAPABILITY, CONTROL AND OPERATION OF THE ECONOMIZER SHALL COMPLY WITH WSEC SEC. 1423. MECHANICAL CODE COMPLIANCE 7.1 WHERE REQUIRED PROVIDE AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS IN EACH SYSTEM DELIVERING HEATING OR COOLING AIR IN EXCESS OF 2000 CFM. DETECTORS BHALL BE LOCATED IN THE MAIN RETURN AIR PER IMC 606. WA2004 #1 U 4 rN w NOT PUBLISHED. ALL RIGHTS RESERVED, THE DRAWING AND SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVE- RGREEN REFRIGERATION INC. NO PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, DISC- LOSED UR DISTRIBUTED TO OTHERS, SOLD, PUB- LISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPEN- SATION TO EVERGREEN REFRIGERATION INC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. rrr rri II ■ iii - - r -,„,, , „ oil N a N L =L[ 1 g N y II I SYMBOL LEGEND SYMBOL ABBV. DESCRIPTION `® DUCT SECTION SUPPLY DUCT SECTION - RETURN /EXHAUST r L RECTANGULAR DUCT ROUND DUCT FLEXIBLE DUCT L MVD MANUAL VOLUME DAMPER y BDD BDD BACKDRAFT DAMPER m MD MOTORIZED DAMPER FD FIRE DAMPER � - � FSD FIRE /SMOKE DAMPER (I20V POWER REQ.) CEILING RADIATION DAMPER SD SMOKE DETECTOR 11J T THERMOSTAT S SENSOR - - - -R R REFRIGERANT LINES - G _,..G G NATURAL GAS LINES 11 CEILING DIFFUSER (SUPPLY) to CEILING DIFFUSER (RETURN /EXHAUST) a EXHAUST FAN (CEILING MOUNTED) IGFI INLINE FAN RECEIVEP - U PROPELLER FAN . JUL 14 2009 I r SIDEWALL DIFFUSE I OWN fF L DUCT FITTING B.O.J. 1.2' 2' DATUM . WWI ail E - UNIT TAG DUCT RISER CINITY MAP :NO C FLO OR PLAN SCALE : 1/8" = 1 o O O SEPARATE PERMIT REQUIRED FOR: ©M anicai Iectrical O Plumbing ❑ Gas Piping City of Tukwila BUILDING DIVISION U SCOPE OF WORK O REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal -H r""!',, in,Ilide additional plan r+e ,rin ' e l fr [ REVIEWED FOR E COMPLIANCE Appnovro AUG 2 i 2000 A T . City of Tukwila 3 UILDING DIVISION FILE COPY Permit No Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt if approved Field d conditions Is : cknowledged• Date: ( 1 City of Tukwila BUILDING DIVISION DUCTWORK 1.1 GENERAL NOTES ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2" TO EACH DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 4 "TO EACH DIMENSION IF DUCTWORK IS ON THE EXTERIOR OF BUILDING. 1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND NUMBER IS THE HEIGHT. 1.3 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT RATING LESS THAN 50, PER IMC 602.2.1. 1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN 1/2 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT PRESSURES ABOVE 1/2 INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS -7. 1.5 ALL DUCT GAUGES PER SMACNA, IMC 603-4. 1.6 ALL DUCT SUPPORTS PER SMACNA, IMC 603 -10. 1.7 ATTACH DIFFUSERS AND GRILLES TO T -BAR GRID PER WA STATE & LOCAL CODES. 1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. INSULATION 2.1 INSULATE OR LINE DUCTWORK PER WA. STATE ENERGY AND MECHANICAL CODES. 2.2 INSULATE REFRIGERANT & CONDENSATE PIPING PER STATE & LOCAL ENERGY CODES. GENERAL CON1 °RACTOR 3.1 GENERAL CONTRACTOR TO PROVIDE AND CUT OPENINGS FOR ALL ROOFTOP, CEILING, FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING AND FIRE PROOF LINING PER IMC & IBC. 3.2 GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATION AND DIMENSIONS WITH ERL BEFORE FRAMING OPENINGS. 3.3 GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING AS REQUIRED FOR MECHANICAL WORK. 3.4 GENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS REQUIRED FOR MECHANICAL WORK. 3.5 GENERAL CONTRACTOR TO PROVIDE ADEQUATE ENGINEERING AS REQUIRED FOR MECHANICAL WORK. 3.6 GENERAL COf ITRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL EQUIPMENT, 3.7 GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY ERL PROVIDE ALL CANT STRIPS AND CURB INSULATION, AND SEAL AGAINST LEAKS. 3.8 GENERAL CONTRACTOR TO PROVIDE ALL CUTTING AND PATCHING OF T -BAR CEILING AS REQUIRED FOR HVAC INSTALLATION. 3.9 GENERAL CONTRACTOR TO PROTECT ALL OPENINGS THROUGH FLOORS PROVIDED FOR DUCTWORK INSTALLATION IN ACCORDANCE WITH TABLE 601 OF INTERNATIONAL BUILDING CODE, WHERE REQUIRED BY SECTION 707 OF IBC. ELECTRICAL 4.1 ERL TO INSTALL ALL LOW VOLTAGE CONTROL WIRING, CONDUIT WILL BE PROVIDED BY ELECTRICAL CONTRACTOR. 4.2 ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS, AND STARTERS FOR MECHANICAL EQUIPMENT. 4.3 ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS WITH ERL MECHANICAL PLAN AND WITH FIELD CONDITIONS. 4.4 ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH. 4.5 ERL TO PROVIDE 7 -DAY NIGHT SETBACK, PROGRAMMABLE TYPE T -STAT WITH CAPABILITY OF 5 °F DEADBAND. 4.6 ERL TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER. 4.7 ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL GCFI OUTLET WITHIN 25 FT OF EACH PIECE OF MECHANICAL EQUIPMENT. PLUMBING 5.1 PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL GAS PIPING FOR MECHANICAL EQUIPMENT PER CODE. 5.2 PLUMBING CONTRACTOR OFFSET VENTS 10 FEET MINIMUM FROM ALL HVAC FRESH AIR INTAKES OR 2' ABOVE HIGHEST POINT OF INTAKE, IMC 401.5.1. 5.3 CONDENSATE DRAINS FROM RTU BY ERI TO DRAIN WITHIN 12" OF UNIT. CONDENSATE DRAINS FOR AIR HANDLERS BY PLUMBER. ENERGY CODE COMPLIANCE 6.1 AT A MINIMUM, EACH FLOOR IS TO BE CONSIDERED A SEPARATE ZONE, VERIFY THERMOSTATIC CONTROL FOR EACH ZONE AS INDICATED ON PLANS. 6.2 OUTSIDE AIR INTAKES, EXHAUST OUTLETS, AND RELIEF OUTLETS SERVING CONDITIONEC' SPACES SHALL BE EQUIPPED WITH DAMPERS WHICH CLOSE AUTOMATICALLY WHEN THE SYSTEM IS OFF OR UPON POWER FAILURE, PER WSEC SEC. 1412.4.1. 6.3 AIR ECONOMIZERS WHERE REQUIRED BY CODE ARE INDICATED BY THE EQUIPMENT SCHEDULE AT 100% CAPABILITY, CONTROL AND OPERATION OF THE ECONOMIZER SHALL COMPLY WITH WSEC SEC. 1423. MECHANICAL CODE COMPLIANCE 7.1 WHERE REQUIRED PROVIDE AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS IN EACH SYSTEM DELIVERING HEATING OR COOLING AIR IN EXCESS OF 2000 CFM. DETECTORS BHALL BE LOCATED IN THE MAIN RETURN AIR PER IMC 606. WA2004 #1 U 4 rN w NOT PUBLISHED. ALL RIGHTS RESERVED, THE DRAWING AND SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVE- RGREEN REFRIGERATION INC. NO PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, DISC- LOSED UR DISTRIBUTED TO OTHERS, SOLD, PUB- LISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPEN- SATION TO EVERGREEN REFRIGERATION INC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. SYMBOL LEGEND SYMBOL ABBV. DESCRIPTION `® DUCT SECTION SUPPLY DUCT SECTION - RETURN /EXHAUST r L RECTANGULAR DUCT ROUND DUCT FLEXIBLE DUCT L MVD MANUAL VOLUME DAMPER y BDD BDD BACKDRAFT DAMPER m MD MOTORIZED DAMPER FD FIRE DAMPER � - � FSD FIRE /SMOKE DAMPER (I20V POWER REQ.) CEILING RADIATION DAMPER SD SMOKE DETECTOR 11J T THERMOSTAT S SENSOR - - - -R R REFRIGERANT LINES - G _,..G G NATURAL GAS LINES 11 CEILING DIFFUSER (SUPPLY) to CEILING DIFFUSER (RETURN /EXHAUST) a EXHAUST FAN (CEILING MOUNTED) IGFI INLINE FAN RECEIVEP - U PROPELLER FAN . JUL 14 2009 I r SIDEWALL DIFFUSE I OWN fF L DUCT FITTING B.O.J. 1.2' 2' DATUM . WWI ail E - UNIT TAG DUCT RISER CINITY MAP :NO C FLO OR PLAN SCALE : 1/8" = 1 o O O SEPARATE PERMIT REQUIRED FOR: ©M anicai Iectrical O Plumbing ❑ Gas Piping City of Tukwila BUILDING DIVISION U SCOPE OF WORK O REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal -H r""!',, in,Ilide additional plan r+e ,rin ' e l fr [ REVIEWED FOR E COMPLIANCE Appnovro AUG 2 i 2000 A T . City of Tukwila 3 UILDING DIVISION FILE COPY Permit No Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt if approved Field d conditions Is : cknowledged• Date: ( 1 City of Tukwila BUILDING DIVISION DUCTWORK 1.1 GENERAL NOTES ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2" TO EACH DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 4 "TO EACH DIMENSION IF DUCTWORK IS ON THE EXTERIOR OF BUILDING. 1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND NUMBER IS THE HEIGHT. 1.3 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT RATING LESS THAN 50, PER IMC 602.2.1. 1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN 1/2 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT PRESSURES ABOVE 1/2 INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS -7. 1.5 ALL DUCT GAUGES PER SMACNA, IMC 603-4. 1.6 ALL DUCT SUPPORTS PER SMACNA, IMC 603 -10. 1.7 ATTACH DIFFUSERS AND GRILLES TO T -BAR GRID PER WA STATE & LOCAL CODES. 1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. INSULATION 2.1 INSULATE OR LINE DUCTWORK PER WA. STATE ENERGY AND MECHANICAL CODES. 2.2 INSULATE REFRIGERANT & CONDENSATE PIPING PER STATE & LOCAL ENERGY CODES. GENERAL CON1 °RACTOR 3.1 GENERAL CONTRACTOR TO PROVIDE AND CUT OPENINGS FOR ALL ROOFTOP, CEILING, FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING AND FIRE PROOF LINING PER IMC & IBC. 3.2 GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATION AND DIMENSIONS WITH ERL BEFORE FRAMING OPENINGS. 3.3 GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING AS REQUIRED FOR MECHANICAL WORK. 3.4 GENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS REQUIRED FOR MECHANICAL WORK. 3.5 GENERAL CONTRACTOR TO PROVIDE ADEQUATE ENGINEERING AS REQUIRED FOR MECHANICAL WORK. 3.6 GENERAL COf ITRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL EQUIPMENT, 3.7 GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY ERL PROVIDE ALL CANT STRIPS AND CURB INSULATION, AND SEAL AGAINST LEAKS. 3.8 GENERAL CONTRACTOR TO PROVIDE ALL CUTTING AND PATCHING OF T -BAR CEILING AS REQUIRED FOR HVAC INSTALLATION. 3.9 GENERAL CONTRACTOR TO PROTECT ALL OPENINGS THROUGH FLOORS PROVIDED FOR DUCTWORK INSTALLATION IN ACCORDANCE WITH TABLE 601 OF INTERNATIONAL BUILDING CODE, WHERE REQUIRED BY SECTION 707 OF IBC. ELECTRICAL 4.1 ERL TO INSTALL ALL LOW VOLTAGE CONTROL WIRING, CONDUIT WILL BE PROVIDED BY ELECTRICAL CONTRACTOR. 4.2 ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS, AND STARTERS FOR MECHANICAL EQUIPMENT. 4.3 ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS WITH ERL MECHANICAL PLAN AND WITH FIELD CONDITIONS. 4.4 ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH. 4.5 ERL TO PROVIDE 7 -DAY NIGHT SETBACK, PROGRAMMABLE TYPE T -STAT WITH CAPABILITY OF 5 °F DEADBAND. 4.6 ERL TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER. 4.7 ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL GCFI OUTLET WITHIN 25 FT OF EACH PIECE OF MECHANICAL EQUIPMENT. PLUMBING 5.1 PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL GAS PIPING FOR MECHANICAL EQUIPMENT PER CODE. 5.2 PLUMBING CONTRACTOR OFFSET VENTS 10 FEET MINIMUM FROM ALL HVAC FRESH AIR INTAKES OR 2' ABOVE HIGHEST POINT OF INTAKE, IMC 401.5.1. 5.3 CONDENSATE DRAINS FROM RTU BY ERI TO DRAIN WITHIN 12" OF UNIT. CONDENSATE DRAINS FOR AIR HANDLERS BY PLUMBER. ENERGY CODE COMPLIANCE 6.1 AT A MINIMUM, EACH FLOOR IS TO BE CONSIDERED A SEPARATE ZONE, VERIFY THERMOSTATIC CONTROL FOR EACH ZONE AS INDICATED ON PLANS. 6.2 OUTSIDE AIR INTAKES, EXHAUST OUTLETS, AND RELIEF OUTLETS SERVING CONDITIONEC' SPACES SHALL BE EQUIPPED WITH DAMPERS WHICH CLOSE AUTOMATICALLY WHEN THE SYSTEM IS OFF OR UPON POWER FAILURE, PER WSEC SEC. 1412.4.1. 6.3 AIR ECONOMIZERS WHERE REQUIRED BY CODE ARE INDICATED BY THE EQUIPMENT SCHEDULE AT 100% CAPABILITY, CONTROL AND OPERATION OF THE ECONOMIZER SHALL COMPLY WITH WSEC SEC. 1423. MECHANICAL CODE COMPLIANCE 7.1 WHERE REQUIRED PROVIDE AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS IN EACH SYSTEM DELIVERING HEATING OR COOLING AIR IN EXCESS OF 2000 CFM. DETECTORS BHALL BE LOCATED IN THE MAIN RETURN AIR PER IMC 606. WA2004 #1 U 4 rN w NOT PUBLISHED. ALL RIGHTS RESERVED, THE DRAWING AND SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVE- RGREEN REFRIGERATION INC. NO PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, DISC- LOSED UR DISTRIBUTED TO OTHERS, SOLD, PUB- LISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPEN- SATION TO EVERGREEN REFRIGERATION INC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. CINITY MAP :NO C FLO OR PLAN SCALE : 1/8" = 1 o O O SEPARATE PERMIT REQUIRED FOR: ©M anicai Iectrical O Plumbing ❑ Gas Piping City of Tukwila BUILDING DIVISION U SCOPE OF WORK O REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal -H r""!',, in,Ilide additional plan r+e ,rin ' e l fr [ REVIEWED FOR E COMPLIANCE Appnovro AUG 2 i 2000 A T . City of Tukwila 3 UILDING DIVISION FILE COPY Permit No Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt if approved Field d conditions Is : cknowledged• Date: ( 1 City of Tukwila BUILDING DIVISION DUCTWORK 1.1 GENERAL NOTES ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2" TO EACH DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 4 "TO EACH DIMENSION IF DUCTWORK IS ON THE EXTERIOR OF BUILDING. 1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND NUMBER IS THE HEIGHT. 1.3 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT RATING LESS THAN 50, PER IMC 602.2.1. 1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN 1/2 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT PRESSURES ABOVE 1/2 INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS -7. 1.5 ALL DUCT GAUGES PER SMACNA, IMC 603-4. 1.6 ALL DUCT SUPPORTS PER SMACNA, IMC 603 -10. 1.7 ATTACH DIFFUSERS AND GRILLES TO T -BAR GRID PER WA STATE & LOCAL CODES. 1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. INSULATION 2.1 INSULATE OR LINE DUCTWORK PER WA. STATE ENERGY AND MECHANICAL CODES. 2.2 INSULATE REFRIGERANT & CONDENSATE PIPING PER STATE & LOCAL ENERGY CODES. GENERAL CON1 °RACTOR 3.1 GENERAL CONTRACTOR TO PROVIDE AND CUT OPENINGS FOR ALL ROOFTOP, CEILING, FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING AND FIRE PROOF LINING PER IMC & IBC. 3.2 GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATION AND DIMENSIONS WITH ERL BEFORE FRAMING OPENINGS. 3.3 GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING AS REQUIRED FOR MECHANICAL WORK. 3.4 GENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS REQUIRED FOR MECHANICAL WORK. 3.5 GENERAL CONTRACTOR TO PROVIDE ADEQUATE ENGINEERING AS REQUIRED FOR MECHANICAL WORK. 3.6 GENERAL COf ITRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL EQUIPMENT, 3.7 GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY ERL PROVIDE ALL CANT STRIPS AND CURB INSULATION, AND SEAL AGAINST LEAKS. 3.8 GENERAL CONTRACTOR TO PROVIDE ALL CUTTING AND PATCHING OF T -BAR CEILING AS REQUIRED FOR HVAC INSTALLATION. 3.9 GENERAL CONTRACTOR TO PROTECT ALL OPENINGS THROUGH FLOORS PROVIDED FOR DUCTWORK INSTALLATION IN ACCORDANCE WITH TABLE 601 OF INTERNATIONAL BUILDING CODE, WHERE REQUIRED BY SECTION 707 OF IBC. ELECTRICAL 4.1 ERL TO INSTALL ALL LOW VOLTAGE CONTROL WIRING, CONDUIT WILL BE PROVIDED BY ELECTRICAL CONTRACTOR. 4.2 ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS, AND STARTERS FOR MECHANICAL EQUIPMENT. 4.3 ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS WITH ERL MECHANICAL PLAN AND WITH FIELD CONDITIONS. 4.4 ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH. 4.5 ERL TO PROVIDE 7 -DAY NIGHT SETBACK, PROGRAMMABLE TYPE T -STAT WITH CAPABILITY OF 5 °F DEADBAND. 4.6 ERL TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER. 4.7 ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL GCFI OUTLET WITHIN 25 FT OF EACH PIECE OF MECHANICAL EQUIPMENT. PLUMBING 5.1 PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL GAS PIPING FOR MECHANICAL EQUIPMENT PER CODE. 5.2 PLUMBING CONTRACTOR OFFSET VENTS 10 FEET MINIMUM FROM ALL HVAC FRESH AIR INTAKES OR 2' ABOVE HIGHEST POINT OF INTAKE, IMC 401.5.1. 5.3 CONDENSATE DRAINS FROM RTU BY ERI TO DRAIN WITHIN 12" OF UNIT. CONDENSATE DRAINS FOR AIR HANDLERS BY PLUMBER. ENERGY CODE COMPLIANCE 6.1 AT A MINIMUM, EACH FLOOR IS TO BE CONSIDERED A SEPARATE ZONE, VERIFY THERMOSTATIC CONTROL FOR EACH ZONE AS INDICATED ON PLANS. 6.2 OUTSIDE AIR INTAKES, EXHAUST OUTLETS, AND RELIEF OUTLETS SERVING CONDITIONEC' SPACES SHALL BE EQUIPPED WITH DAMPERS WHICH CLOSE AUTOMATICALLY WHEN THE SYSTEM IS OFF OR UPON POWER FAILURE, PER WSEC SEC. 1412.4.1. 6.3 AIR ECONOMIZERS WHERE REQUIRED BY CODE ARE INDICATED BY THE EQUIPMENT SCHEDULE AT 100% CAPABILITY, CONTROL AND OPERATION OF THE ECONOMIZER SHALL COMPLY WITH WSEC SEC. 1423. MECHANICAL CODE COMPLIANCE 7.1 WHERE REQUIRED PROVIDE AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS IN EACH SYSTEM DELIVERING HEATING OR COOLING AIR IN EXCESS OF 2000 CFM. DETECTORS BHALL BE LOCATED IN THE MAIN RETURN AIR PER IMC 606. WA2004 #1 U 4 rN w NOT PUBLISHED. ALL RIGHTS RESERVED, THE DRAWING AND SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVE- RGREEN REFRIGERATION INC. NO PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, DISC- LOSED UR DISTRIBUTED TO OTHERS, SOLD, PUB- LISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPEN- SATION TO EVERGREEN REFRIGERATION INC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS.