HomeMy WebLinkAboutPermit D09-039 - GAMEFLY - STORAGE RACKSGAMEFLY 12783 GATEWAY DR EXPIRED 10 -12 -09 D09 -039 Parcel No.: 2716000060 Address: 12783 GATEWAY DR TUKW Suite No: Tenant: Name: GAMEFLY Address: 12783 GATEWAY DR , TUKWILA WA Contact Person: Name: JERRY HARRISON Address: 8230 S 192 ST , KENT WA 98032 Phone: 425 - 251 -5700 Contractor: Name: HARRISON EQUIPMENT CO INC Address: 8230 S 192 ST , KENT WA 98032 Phone: 425 - 251 -5700 Contractor License No: HARRIEC101PN DESCRIPTION OF WORK: INSTALL BULK RACK/SHELVING Value of Construction: Type of Fire Protection: Type of Construction: doc: IBC -10/06 Cit34if Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Owner: Name: RREEF AMERICA REIT II CORP/ Address: PO BOX 4900 #207 , SCOTTSDALE AZ 85261 Phone: $59,875.00 DEVELOPMENT PERMIT * *continued on next page ** Permit Number: D09 -039 Issue Date: 04/15/2009 Permit Expires On: 10/12/2009 Expiration Date: Fees Collected: $1,672.67 International Building Code Edition: 2006 Occupancy per IBC: D09 -039 Printed: 04 -15 -2009 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: City (*Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us N N Permit Number: D09 - 039 Issue Date: 04/15/2009 Permit Expires On: 10/12/2009 Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. Start Time: End Time: Fill 0 c.y. End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am aut •rized to sign and obtain this development permit. Signature: t Date: b-4 I SS D doc: IBC -10/06 Print Name: WI U ( � <nL 1 ' ` Qk� U Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D09 -039 Printed: 04 -15 -2009 Parcel No.: 2716000060 Address: 12783 GATEWAY DR TUKW Suite No: Tenant: GAMEFLY 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: D09 -039 Status: ISSUED Applied Date: 03/16/2009 Issue Date: 04/15/2009 2: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 3: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Manufacturers installation instructions shall be available on the job site at the time of inspection. 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ** *FIRE DEPARTMENT CONDITIONS * ** 9: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 10: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 11: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 12: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 13: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) doc: Cond -10/06 D09 -039 Printed: 04 -15 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 14: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 15: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 16: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 17: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 18: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 19: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 20: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 21: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 22: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) The path of egress shall require emergency lighting until exit discharge is accomplished. 23: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 24: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 25: Clearance between ignition sources, such as light fixtures, heaters, and flame - producing devices, and combustible storage shall be maintained in an approved manner. (IFC 305.1) doc: Cond -10/06 D09 -039 Printed: 04 -15 -2009 0 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 26: Storage shall be maintained 2 feet or more below the ceiling in nonsprinldered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.2.1) 27: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 28: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 29: These plans were reviewed by Inspector 511. If you have arty questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10106 * *continued on next page ** D09 -039 Printed: 04 -15 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: f doc: Cond -10/06 D09 -039 Date: O I S - o / ordinances governing or local laws regulating Printed: 04 -15 -2009 • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.atulcwila.wa.us Site Address: I 2 A3 Givatery 02_ SITE LOCATION Tenant Name: GRMCFL- y Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Property Owners Name: Mailing Address: Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: TZ y i-fic,2cIUK/ Mailing Address: eZ 3 d 5. 1 9 d" S r E -Mail Address: Company Name: RtiCK 0ema61✓a G 4% ∎ AJc* *IM6 Mailing Address: 41Z W _ 1 A-Ol v ' t 26 4 Contact Person: ( AQN (k. 0HA-v /4-4 H•\Applications\Forms- Applications On Line \2009 Applications U-2009 - Permit Application.doc Revised: 1 -2009 bh Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) King Co Assessor's Tax No.: X? 000"" Suite Number: Floor: City New Tenant: ® Yes ..No State Day Telephone: (2.-C) Z51 -5 10 0 ICei jr l t ,,vi City State E -Mail Address: Fax Number: <4� 2, / —9 S 7Z GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: Zip State City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: Zip City Contact Person: Day Telephone: Fax Number: 6eLd1J014 : State Zip ENGINEER Q+' RECORD - All plans must be wet stamped by Engtlneer of Record State ►Zo4 Zip City Day Telephone: 0( &,, Z4a .7 a/ 0 E -Mail Address: Fax Number: ` ` " . J6 13 Page 1 of 6 • • L BUDING PERMIT INFORMATION - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 5 81J Existing Building Valuation: $ Scope of Work (please provide detailed information): �]LISPILL.. BU LK RAC tic bieL1110.1(v Will there be new rack storage? ❑ Yes Z. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. li 1Applications \Forms-Applications On Lme12009 Applications \I -21X19 - Permit Application.doc Re,,sed 1 -21)19 bh Page 2or( Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per 1130 l' Floor 2 Floor 3r Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck • • L BUDING PERMIT INFORMATION - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 5 81J Existing Building Valuation: $ Scope of Work (please provide detailed information): �]LISPILL.. BU LK RAC tic bieL1110.1(v Will there be new rack storage? ❑ Yes Z. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. li 1Applications \Forms-Applications On Lme12009 Applications \I -21X19 - Permit Application.doc Re,,sed 1 -21)19 bh Page 2or( Print Name: PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE R AUTHORIZED AGENT: Signature: t-laee isal Mailing Address: BZ G S _ / 9 z6La Sr' H \Applications \Forms-Applications on Line \2009 Applications \I-2009 - Permit Application.doc Reused 1 -2009 hh Date: J//6/0 9 Day Telephone: (4Z0 2....5"(---,5 o "PO 3z City State Zip Date Application Accepted: Date Application Expires: Staff Initials: a4 (2 Page 6 of 6 Receipt No.: R09 - 00578 Initials: User ID: Payee: WER 1655 ACCOUNT ITEM LIST: Description MARY JANE MURPHY Payment Cash Authorization No. PHOTOCOPIES /DUP SERVICES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 2716000060 Permit Number: D09 -039 Address: 12783 GATEWAY DR TUKW Status: APPROVED Suite No: Applied Date: 03/16/2009 Applicant: GAMEFLY Issue Date: TRANSACTION LIST: Type Method Descriptio Amount 2.00 Account Code Current Pmts 000/341.690 2.00 Total: $2.00 Payment Amount: $2.00 Payment Date: 04/15/2009 02:19 PM Balance: $0.00 PAYMENT RECEIVED doc: Receiot -06 Printed: 04 -15 -2009 Parcel No.: 2716000060 Address: 12783 GATEWAY DR TUKW Suite No: Applicant: GAMEFLY Receipt No.: R09 - 00412 Initials: WER User ID: 1655 Payee: HARRISON EQUIPMENT TRANSACTION LIST: Type Method Descriptio Amount Payment Check 46177 1,670.67 ACCOUNT ITEM LIST: Description BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Account Code Current Pmts 000/322.100 000/345.830 640.237.114 RECEIPT Total: $1,670.67 Permit Number: D09 -039 Status: PENDING Applied Date: 03/16/2009 Issue Date: Payment Amount: $1,670.67 Payment Date: 03/16/2009 11:28 AM Balance: $0.00 1,009.80 656.37 4.50 PAYMENT RECEIVED doc: Receiot -06 Printed: 03 -16 -2009 BY....,. G. OHANIAN DATE . 3 -5 -09 SUBJECT STRUCTURAL CALCULATIONS OF SHELVING FOR: GAMEFLY 12783 GATEWAY DRIVE TUKWILA, WA. 98168 PER IBC 2006 EDITION STORAGE SHELVING CAPACITY: 100 # / LEVEL CALCS. 1 THRU 3 DRAWINGS: RD -14005 RAdK DENIdN & ENdINEERINd do. 412 WA fiT BROADWAY, OUITE 204 dLENDALE, CIA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 D09- 039 EXPIRES 12 -26 -09 SHEET NO, 1 JOB NO. RD -14005 Pisirco TO an rAVlew annr ai �►� C E WE ®F AP COMPLI N APR 14 1009 BU ILDING City of Tukwila DI VISION RECEIVED MAR 16 2009 PERMIT CENTER BY G. OHANIAN RACK DEMON Sc ENdINEERIN( CO. DATE 3 - - 09 412 WAOT BROADWAY, QUITE 204 SUBJECT dLENDALE, dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 N N N— an O ro DRB "SRB" BEAM 48" FRONT VIEW W =D.L.+ 3 L.L. W= .13 D.L +.47 L.L. ' K SRR TYP U.N.O. DRB ORB 0 t�.13 I x =.05 S x =.03 FY= 36 KSI. LOAD PER COLUMN L.L.= 2 x 14x.1K =.47 K 3 2 cm_ 100 # / LEVEL 50 # / BEAM S =.99 (USGS WEB SITE, "SITE CLASS D ") 1 =1 NO PUBLIC ACCESS R =4 18 ", I DRB M= 48 "x 05 = .3 "K 8 S R = 2 "K = .02 <.03 SEISMIC DESIGN V Rx1 4 x W IBC 2006 WORKING ASCE 7 -05 (SEC. 15.5.3) PER RMI SPECS. STRESS V .99x1x.6 1 K M — .1 —9 "K 4x1.4 cot. 2 SHEET NO 2 JOB NO.. RD -14005 36" 36" 36" I 36" Y DRB DRB TOP TIES AT" DRB DRB DRB DRB EVERY BAY DRB SIDE VIEW Conterminous 48 States 2005 ASCE 7 Standard Latitude = 47.4884 Longitude = — 122.2755 Spectral Response Accelerations SMs and SM1 SMs = Fa x Ss and SM1 = Fv x S1 Site Class D — Fa = 1.0 ,Fv = 1.5 Period Sa (sec) (g) 0.2 1.477 (SMs, Site Class D) 1.0 0.762 (SM1, Site Class 0) Conterminous 48 States 2005 ASCE 7 Standard Latitude = 47.4884 Longitude = — 122.2755 Design Spectral Response Accelerations SDs and SDI SDs = 2/3 x SMs and SDI = 2/3 x SM1 Site Class D — Fa = 1.0 ,Fv = 1.5 Period Sa (sec) (g) 0.2 0.985 (SDs, Site Class D) 1.0 0.508 (SD1, Site Class D) , BY, , G. OHANIAN RACK DEOI(N & ENdINEERIN( CO. DATE . 3 -5 -09 412 WAOT BROADWAY, QUITE 204 SUBJECT GtLENDALE, CA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 COLUMN ANALYSIS P= 14 2 COL. W =.13 +.7 - .83 K D.L. L.L. COMBINED STRESS RATIO P + M = .83 + 9 = .79 <1.33 P M 3.6 1.6 BASE PLATE T= 0 0 =.7 100% LOAD ANCHOR SHEAR = •t0K= .05K 2 MOMENT AT BEAM CONNECTION M _ .9 +.88 = . CONN. 2 V _ .252x3.14 x80x.4 =1.5 RIVET 4 Ma = 1.5 "x1.33 =3.0 " CONN OVERTURNING 36" DEEP SHELVING F =36KS A =.28 S mtn .07 rmin .52 .10 "x.5x1.15 = 13.8 "K M ST= M = .6 " 21.6 "K NO UPLIFT .25 "0 RIVET F =80 KSI USE CROSS AISLE TIE AT EVERY BAY PER DETAIL DRAWING K1 18 =34 r .52 F 12.8Ks P F =3.6 M =SxF = 1.6 " BEAM - - �f 4 2" 2" OO OO (2)-1/4"� WEDGE ANCHORS, 2" EMB. Tv SHEET NO. 3 JOB NO. RD -14005 POST 18" DEEP SHELVING K x2x120 "x.5x1.15 = 13.8" M •1 MR = .6 "= 10.8 "K UPLIFT = 13.8 "K - 10.8 "K =. 18" 1)09- 039 7_I /.14 c 0 1 re Ce 3" /d sOarr ■1 5 j LA, I 01, / el6 4 ÷.• 7 72: 9 k 7 7 1 4 —4 77 7 4 7 . — 2 2- 4. 0 RECEIVED MAR 16 2009 PE e- PERMIT CENTER _ Lc -1 4d s lte. , • e- 7 6' y *44V. PILE COPY B 4-,n1 an review aorrnvai .et 4110,4 4's "Inag effiC A. I 11 „ 4 '" °774)‘'e''el Doc. 1 .•-•` t> re . -cp r r P 4 5 ,z- C e r 6 e v 6. 7 /V G. '. q 7 -"r" 3S 41 ‘ g 4, 71-G C. 1 0 / ( 36* a /A-- e 7 / 4 Co"f 4 0,0 /5 2 /1 4 r - / -1.- 7 d 4 e 5 e- 7 6 A- - / 7 '0,r a a <:;) DAVIS BACON MATERIAL HANDLING 448WORTH ST, LOS ANGELES, CA oo€3 /16140.1821 G1100632 • FAx 323-227-1928 winutribbaconmh.com JERRY HARRISON 8230 S 192 ST KENT WA 98032 RE: Permit No. D09 -039 12783 GATEWAY DR TUKW Dear Permit Holder: City of Tukwila Department of Community Development Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 10/12/2009. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 10/12/2009, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. D09 -039 8211/1 C....th......f.... D.... - T.t....:f- T11.....1 nnrnn _ nom .,nom ..,. ..�.,.. Jim Haggerton, Mayor March 31, 2009 Re: Permit #D09 -039 • HARRISON EQUIPMENT COMPANY, INC Material Handling, Storage and Packaging Equipment Et Supplies The commodities to be stored on the shelving are all video games in packets set in bin boxes or closed cartons for easy access for distribution. Gamefly is the largest distributor by mail of rented video games similar to Netflix for movies. There is no storage above 12' and the 10' level at the top of the rack is a dust cover with no storage over 10'. cnAFISLA MAR 31 2009 PERMIT CENTER CORRECTION LTR# 8230 South 192 Street * Kent, WA 98032 -1195 • (425) 251 -5700 * (425) 251 -9572 fax w O31 1 March 24, 2009 Jerry Harrison 8230 S 192 St Kent, WA 98032 RE: CORRECTION LETTER #1 Development Permit Application Number D09 -039 Gamefly —12783 Gateway Dr Dear Mr. Harrison, This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building and Fire Departments. At this time the Planning and Public Works Departments have no comments. Building Department: Dave Larson at 206 431 -3678 if you have questions regarding the attached memo. Fire Department: Al Metzler at 206 -575 -4407 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, ifer Marshall it Technician encl File No. D09 -039 • City of 7`i1 la Department of Community Development Jack Pace, Director P:\Permit Center\Correction Letters\2009\D09 -039 Correction Letter #1.DOC jem Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 J Building Division Review Memo • M Date: March 20, 2009 Project Name: Gamefly Permit #: D09 -039 Plan Review: Dave Larson, Senior Plans Examiner Tukwila Building Division Dave Larson, Senior Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. The scale noted on the floor plan may not be correct. It is shown as 1/16 inch = 1 ft. If this were correct all the man doors shown would be 6 ft. wide so I am assuming that this plan was doubled in size without changing the scale. Please submit a floor plan with the correct scale. 2. If the correct scale is 1/8 inch = 1 ft., then the addition of this shelving will increase the travel distance to more than 100 ft. from the most remote point in the space to an exit. This would require two exits per section 1015.1 item 2 IBC and emergency lighting per section 1006.3 item 1. Two exits exist but were not required before the addition of shelving and emergency lighting may not exist. An egress path provided with emergency lighting would solve the problem. This egress path would need to be designed to connect the two provided exits and be routed so that any point in the space is less than 100 ft. travel distance from this egress path. Once a person reaches this egress path they need to have a choice of two distinct paths of travel to two separate exits. This portion of the egress system needs to meet the emergency lighting performance requirements of section 1006.4 IBC. If a cross aisle were added to the middle of the shelving area perpendicular to the other aisles, an emergency lighted means of egress path could be along a straight line between the two exit doors. Please show the chosen path required to be emergency lighted on the floor plan and add notes for the addition of emergency lighting along this path. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. Fire Prevention Bureau Review Memo • Date: March 18, 2009 Project Name: Gamefly Address: 12783 Gateway Dr Permit #: D09 -039 Plan Reviewer: Al Metzler, Fire Project Coordinator 2. Provide a detailed list of commodities to be stored on the racks. Tukwila Fire Prevention Bureau AI Metzler, Fire Project Coordinator The Fire Prevention Bureau conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. 1. Provide a scaled floor plan which shows exact locations of rack placements. Should there be questions concerning the above requirements, contact the Fire Prevention Bureau at 206- 575 -4407. No further comments at this time. PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D09 -039 DATE: 03 -31 -09 PROJECT NAME: GAMEFLY SITE ADDRESS: 12783 GATEWAY DR Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: 4 ilding Division Public Works Complete Comments: Documents/routing slip.doc 2 -2 B -02 V" n • APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Fire Prevention Structural DETERMINATI N OF COMPLETENESS: (Tues., Thurs.) Incomplete U Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS RO/TING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: I DATE: Planning Division Permit Coordinator DUE DATE: 04-02-09 DATE: Not Applicable DUE DATE: 04-30-09 Not Approved (attach comments) ❑ u u Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: � (• y PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D09 -039 PROJECT NAME: GAMEFLY SITE ADDRESS: 12783 GATEWAY DR X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # DATE: 03 -16 -09 Revision # After Permit Issued DEP RTMENTS: Building [vision Public Works ri F Vik ire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS RO T ING: Please Route Structural Review Required ❑ No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 ❑ Permit Coordinator DUE DATE: 03-17 -09 DUE DATE: 04-14 -09 Not Approved (attach comments) DATE: Planning Division Not Applicable Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 3 — 3 i — d 9 Plan Check/Permit Number: D09 -039 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Gamefly Project Address: 12783 Gateway Dr Cfl V ! LA MAR 31 2009 PERM1?C Contact Person: J ��e y' f 7. S o&/ Phone Number: 42J - - Summary of Revision: Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: `7At- Entered in Permits Plus on 0 \applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Name Role Effective Date Expiration Date MUNKO, TAMMY K Cancel Date 01/01/1980 Bond Amount MURPHY, MARY JANE 6 01/01/1980 LPM4046513 HARRISON, SARA J Until Can 01/01/1980 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 6 COLONIAL AM CAS Et SURETY OF MD LPM4046513 07/22/2001 Until Can 07/31/2001 5 COLONIAL AM CAS Et SURETY OF MD LPM4046513 09/13/199907/22 /2001 $6,000.00 4 STAR INS CO SA1108716 10/15/1994 Until Cancelled 09/17/1999 $6,000.00 AMERICAN Untitled Page • General /Specialty Contractor A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company HARRISON EQUIPMENT CO INC 4252515700 8230 S 192ND ST KENT WA 98032 KING Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 600335469 ACTIVE HARRIEC101 PN CONSTRUCTION CONTRACTOR 10/15/1990 5/7/2010 GENERAL UNUSED Business Owner Information Bond Information https://fortress.wa.gov/lni/bbip/Detail.aspx Page 1 of 3 04/15/2009 NORTH SITE PLAN —AREA OF WORK 1ST FLOOR KEY PLAN Ng SCALE: 1"-30' \ \Wkst -4 \documents\ CAD \1987 - 1989 \8704 -7 \ITT \r ap_web_mapquest.gif 9 VICINITY MAP SEPARATE PERMIT REQUIRED FOR: is Mechanical Electrical IS Plumbing 01 Gas Piping City of Tukwila BUILDING DIVISION 1) 2) 3) 4) 5) 6) LEGAL DESCRIPTION 6 GATEWAY CORPRETE CENTER TAX ID. NUMBER 2716000060 - 0060 -08 SCOPE OF WORK CONSTRUCT NEW NONBEARING WALLS. BUILDING ENVELOPE NOT CHANGED. BUILDING & SITE STATISTICS BUILDING CODE: IBC 2004 - ZONING: C /LI - TYPE OF CONSTRUCTION: V -B SPRINKLERED - OVERALL BUILDING FOOTPRINT: 41,077 S.F. - TENANT AREA THIS PERMIT WAREHOUSE: 8,268 S.F. OFFICE: 2,127 S.F. TOTAL: 11,395 S.F. OCCUPANCY GROUP: S -1 & B ENERGY CODE NOTES HEAT IS VIA GAS, NO ELECTRIC HEAT ALLOWED -NO CHANGE TO ENVELOPE PROVIDE VAPOR ON ALL WALL TO THE WARM SIDE CAULK AND SEAL ALL OPENINGS TO OUTSIDE OR UNHEATED SPACES INCLUDING WEATHER - STRIPPING AT ALL EXTERIOR DOORS. MAXIMUM ALLOWABLE LOAD FOR SWITCH IS 80% OF 20 AMP CIRCUIT PROVIDE DUAL LEVEL SWITCHING IN ALL ROOMS ADJACENT TO EXTERIOR WINDOES LESS THAN 60% OF THE FIXTURES ARE NEW INSTALLED WATTAGE NOT INCREASED AND SPACE USE NOT CHANGED, ALTERATION EXPANSION REVISIONS No changes shall be dam a to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal ,- j i'i : .'ter? P,' jt; I EXPIRES /2 _ 2 o l I SIGNED FOR SHELVING ONLY D09- 039 REVIc WED FOR CODE COMPLIANCE PPR VED APR 14 2009 City of J Ir/ila BUILDING DIVISION FILE COPY Permit No. 1 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and condition acknowledged. BY Date: 6 City Oflblkwila BUILDING DIVISION .&LT z-E cS 6- e-fz Y 12-7 6 3 c4 - ►e 7 , it/ 99/C5 DAVIS BACON MATERIAL HANDLING 4438 WORTH ST., LOS ANGELES, CA 90063 323 227 1921. 800432 - 1921 • FAX 323 -227 - 1926 WwW+cllVitbacon t1Acovti" RECEIVED MAR 16 2009 PERMIT CENTEI• SD -1 NEW "MR SLIM" MITSUBISHI WALL _3 3 /8'HVAC 4 NEW NEMA L5 -30R DEDICATED OUTLETS AT +24" AFF SERVER LUNCH VENTILATION. SHUT WINDOW BLINDS BEFORE INSTALLING PLYWOOD. ,IT filliP"'moinias,R.- ' -�� ADD PLYWOOD TO 1 5/8" STL STUD AT INSIDE OF WINDOW SILL AND HEAD, ATTA RM U 78' - gar 1" PLYWOOD TO STUD (PAINT BOTH SIDES La Fj / .— 1 9 SF/ 500 = 17 OCC 3 4 . LEGEND EXISTING WALL NEW STEEL STUD WALL TO UNDERSIDE OF CEILING W/ SOUND INSULATION EXISTING WALL TO BE REMOVED. NEW DOOR EXISTING DOOR FOUR -PLEX OUTLET DUPLEX OUTLET A WAIL TELEPHONE OUTIET AND DMA, MUDRING, CONDUIT AND PULL STRING ONLY. EXHAUST FAN Q J -BOX FOR POWER AND /OR PHONE ILLUMINATED EXIT SIGN W/ PATHWAY UGHTING & BA I ItHY BACKUP v [EXIT I N N D NOT USED 2 3 -1 3 NOT USED RECESSED 2X4 -2 TUBE FLUORESCENT 66 WATT UGHT FIXTURE W/ PARABOUC LENSE RECESSED 2X2 -2 TUEE FLUORESCENT 66 WATT LIGHT FIXTURE W/ PARABOLIC LENSE SURFACE MOUNT 2 TUBE FLUORESCENT 66 WATT UGHT FIXTURE RECESSED COMPACT FLUORESCENT UGHT FIXTURE, 32 WATTS EXISTING NEW DEDICATED SWITCH ROOM SCHEDULE FLOOR: REMOVE EX. CARPET, NEW STATIC GUARD VCT BASE: NEW 4" BASE : CEILING: NEW GYP BD CEILING ( +8'0" AFF) REMOVE EX. SUSPENDED ACOUSTICAL CEIUNG TILE LEAVE . RI' 9' WALL TYPES (SI =SOUND INSULATE) ENERGY CODE NOTES STL STUD Cy 24" O.C. TO ACOUSTICAL CEILING, GYP. BD. BOTH SIDES D 00R SCHEDULE (LEVER HANDLES) EXISTING DOORS NO CHANGES 3' X 7' S.C. WOOD DOOR, WOOD JAMB (STAINED), 1 -1/2 PAIR BUTTS, WALL STOP, LOCKSET 1) HEAT IS VIA GAS, NO ELECTRIC HEAT ALLOWED 2) PROVIDE VAPOR ON ALL WALL TO THE WARM SIDE 3) CAULK AND SEAL ALL OPENINGS TO OUTSIDE OR UNHEATED SPACES INCLUDING WEATHER- STRIPPING AT ALL EXTERIOR DOORS. , MAXIMUM ALLOWABLE LOAD FOR SWITCH IS .80% OF 20 AMP CIRCUIT. PROVIDE DUAL LEVEL SWITCHING IN ALL ROOMS ADJACENT TO EXTERIOR 5) WINDOWS 6) NO CHANGE TO EXTERIOR ENVELOPE FIRE ALARM SYSTEM 1) PROVIDE A FULLY OPERATIONAL AND CODE COMPLYING FIRE ALARM SYSTEM TO INCLUDE, BUT NOT LIMITED TO HORN /STROBES, PULL STATIONS, DUCT SMOKE DETECTORS AND INTERIOR RECESSED ENUNCIATOR PANEL AS REQUIRED BY CITY OF TUKWILA AND CONNECT TO EXISTING . FIRE ALARM PANEL LOCATED IN EX. ELECTRICAL ROOM. REVIEWED FOR CODE COMPLIANCE APPROVE APR 14 2009 City of Tukwila BUILDING DIVISION S� er 4 I EXPIRES �2_0 SIGNED FOR SHELVING ONLY 1 - 2 6 3 ove--Y T'uG� L� 4J J 8 /Gc9 uaL .E `'/'' $ 1 c (f 4 &G - Ct G .J DAVIS BACON MATERIAL HANDLING 4436 WORTH St, LDS ANGELES, CA 90063 323.227 4 •davisbR ��� 11328 oom / T IV! 7 %- J • .. r ajAL 112'. _ 7; . CIT O T LA MAR 3 12009 PE R MR- CENi R CORRECTION LTR# EXPIRES 12 - - 1 . - � v Q 0 � ' s� TI 0 �116P P� TE .1 3/32" 6 � `� i �ili Q u Pd s1' •n INTERMEDIATE POSTS --,_, III II II �� / I 11 . � I I I II I " I I I 1/4"0 RIVET ASTM A576 -90B F, � a II I I 1 , / � I I ASTM A576 -90B C 1 / 4 "0 ASTM 41 ii .. RIVET A576 -90B 1 1 1 1/2 " ,. 1/4T1" I I I ---11--- i g 9 I —1 f— ' g 3 1/4" ; n O 1 O 0 TIE PLATE 3" ,� � t _ < • e e ° e •d ? °, tV CD a 1 3/4" y I I a 'e � a N 2 .— — {tt)-- — 4(Df — III I , END POSTS 1 /4 "0 RIVET ASTM A345 -79 N z / < 1 "SRB" BEAM 1/4"0 RIVET ASTM A345 -79 TIE PLATE ' "SS" BEAM t =14 GA. "TT" (2) -1/4 "0 WEDGE ANCHOR PER BASE PL. (1) -1/4 "0 WEDGE ANCHOR PER BASE PL. 2" EMB. 2" EMB. 14 GA. t =11 GA, 14 GA. SHELVING COLUMN (1 BEAM CONNECTION ( BEAM CONNECTION BASE PLATE DETAIL ( 4 D CI g 0 tl U t , 4/110 \' " a ' t =14 GA. 16 � 3 � 1 e >> 0 , 3 ,,i. 1 ING t V di kr 051 - kr cN IN c RE view ED APR 2009 City of ve BUIL ma L ®I A D�Vj 31oN , TOP TIE 5 48" 18" 36" 36" 36" 36" NO ES: 1— DESIGN OF STEEL STORAGE AND CALCULATIONS OF THE INTERNATIONAL 2 —STEEL FOR ALL SHAPES 3— CONCRETE SLAB 5" 4— STORAGE SHELVING 5 —ALL SHELVING INSTALLATIONS LOCATIONS A PERMANENT IN AREA SHOWING THE SHELVING AS SHOWN BY THESE DRAWINGS ARE IN COMPLIANCE WITH THE REQUIREMENTS BUILDING CODE 2006 EDITION FY =36 KSI. ASTM A570 -85 GR.36 (EXCEPT AS NOTED) THICK 2500 PSI. SOIL BEARING CAPACITY 500 PSF CAPACITY 100 # / LEVEL SHALL DISPLAY IN ONE OR MORE CONSPICUOUS PLAQUE EACH NOT LESS THAN 50 SQUARE INCHES MAXIMUM PERMISSIBLE UNIT LOAD OF 100 #/ LEVEL RECEIVED ' MAR 1 2009 PERMIT CENTER S DRB © DRB DRB DRB ' r 1�z r TOP TIES SRR TYR. • .AT Y BAY EVER U.N.O. j O 5 0 DRB DRB 0 DRB DRB z I. { 0 Q REV. DATE REVISION 1 .. , s A , , , . % 1 RACK DESIGN AND' ENGINEERING 412 WEST BROADWAY, SUITE #204, GLENDALE, CA. 91204 u Q DRB _ DRB DRB _ , � SCALE: NONE DRAWN BY: X U DATE: 3 -5 -09 ` .:. . ' • :• ' • • . • ° .. .. a. . •" .. , ' '' 4%• f' 5956E �Q � � � 4 'crs•r n w 1 '� � �' � s s'ONAL E\' PROJECT: G A. NA E F 9 6 � 12783 GATEWAY DRIVE, TUKWILA, WA. 98168 FRONT VIEW SIDE VIEW STORAGE SHELVING DETAILS J RD OB 14005 SHEET NO. EXPIRES 12 - -