HomeMy WebLinkAboutPermit D09-145 - B I INC - OFFICES AND LOBBYB I INC 14220 INTERURBAN AV S D09 -145 Tenant: Name: B I, INC. Address: 14220 INTERURBAN AV S , TUKWILA WA Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 3365901881 Permit Number: D09 -145 Address: 14220 INTERURBAN AV S TUKW Issue Date: 08/13/2009 Suite No: Permit Expires On: 02/09/2010 Owner: Name: DBSI FAIRWAY LLC 519999 Address: C/O DDRS TAX DEPT , 12426 W EXPLORER DR #100 83713 Phone: Contact Person: Name: DAVE KEHLE Address: 1916 BONAIR DR SW , SEATTLE WA 98188 Phone: 206 433 -8997 Contractor: Name: BOYCE CONSTRUCTION Address: 270 S HANFORD ST #109 , SEATTLE WA 98134 Phone: 206 - 264 -8085 Contractor License No: BOYCECI066QQ doc: IBC -10/06 City* Tukwila • DEVELOPMENT PERMIT * * continued on next page ** Expiration Date: 01/09/2010 DESCRIPTION OF WORK: DEMOLISH SOME EXISTING NON - BEARING WALLS, INSTALL NEW NON - BEARING WALLS FOR OFFICES AND LOBBY, AND MODIFY CEILING GRID AND LIGHTS PER PLAN. Value of Construction: $8,300.00 Fees Collected: $412.71 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2006 Type of Construction: VB Occupancy per IBC: 0008 D09 -145 Printed: 08 -13 -2009 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: City afnukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us N N Start Time: Volumes: Cut 0 c.y. Number: 0 Size (Inches): 0 End Time: Fill 0 c.y. Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: The granting of this permit does not pre doc: IBC -10106 Permit Number: D09 -145 Issue Date: 08/13/2009 Permit Expires On: 02/09/2010 Date: 0 1.110 I hereby certify that I have read and ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complies whether specified herein or not. e to give authority to violate or cancel the provisions of any other state or local laws regulating construction r th ormance of work. I am authorized to sign and obtain this development permit. Signature: Date: t3 ‘67 Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D09 -145 Printed: 08 -13 -2009 Parcel No.: 3365901881 Address: 14220 INTERURBAN AV S TURIN Suite No: Tenant: B I, INC. 1: * * *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: D09 -145 Status: ISSUED Applied Date: 07/22/2009 Issue Date: 08/13/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: ** *FIRE DEPARTMENT CONDITIONS * ** 14: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: doc: Cond -10/06 D09 -145 Printed: 08 -13 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us 15: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 16: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 17: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 18: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 19: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 20: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 21: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 22: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 23: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 24: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 25: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 26: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 27: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 28: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) doc: Cond -10/06 D09 -145 Printed: 08 -13 -2009 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us 29: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 30: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 31: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 32: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. (IFC 505.1) 33: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 34: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 35: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * * continued on next page ** D09 -145 Printed: 08 -13 -2009 Signature: Print Name: doc: Cond -10/06 eciztea &ybuita— • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Date: 1 3 6 9 D09 -145 Printed: 08 -13 -2009 CITY OF TUKWII Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Site Address: 14220 Interurban Avenue South Tenant Name: B.I., Inc. Mailing Address: 631 Strander Blvd. Suite G Name: Dave Kehle Mailing Address: 1916 Bonair Drive SW E -Mail Address: dkehle @dkehlearch.com Company Name: David Kehle, Architect Mailing Address: 1916 Bonair Drive SW Contact Person: Dave Kehle E -Mail Address: dkehle @dkehlearch.com Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Property Owners Name: do CB Richard Ellis Asset Services E -Mail Address: H:WpplieationsWorms- Applications On Line \2009 Applications \I -2009 - Permit Application.doc Revised: t -2009 bh King Co Assessor's Tax No.: 336590288206 Suite Number: A - RD O Floor: Seattle City 1 New Tenant: ® Yes ❑ ..No 98188 Zip WA State CONTACT PERSON - who do we contact when your permit is ready to be issued Day Telephone: (206) 433 - 8997 Seattle WA 98188 City State Fax Number: (206) 246 -8369 GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: TBD Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Seattle State City State Day Telephone: (206) 433 -8997 Fax Number: (206) 246 -8369 Zip Zip WA 98116 Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: WA Mailing Address: State Zip City Contact Person: Day Telephone: Fax Number: Page 1 of 6 • BUILDING PERMIT INFO TION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ 8,300 Existing Building Valuation: $ 2 Scope of Work (please provide detailed information): Demolish some existing non bearing walls, install new non bearing walls for offices and lobby, modify ceiling grid and lights, per plan. Will there be new rack storage? ❑ Yes .. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If `yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If 'yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: Vµ plicationsWorms- Applications On Line 2009 Applications \I -2009 - Permit Applicationdoc Revised: 1 -2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1 Floor 20,200 1,500 V -B B 2nd Floor 3' Floor Floors thru Basement Accessory Structure' Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck • BUILDING PERMIT INFO TION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ 8,300 Existing Building Valuation: $ 2 Scope of Work (please provide detailed information): Demolish some existing non bearing walls, install new non bearing walls for offices and lobby, modify ceiling grid and lights, per plan. Will there be new rack storage? ❑ Yes .. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If `yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If 'yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: Vµ plicationsWorms- Applications On Line 2009 Applications \I -2009 - Permit Applicationdoc Revised: 1 -2009 bh Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 R O ' / iT ZED AGENT: Signature: �y C � Date: ell IZ 6 1(9 Print Name: David Kehl Day Telephone: (206) 433 - 8997 Mailing Address: 1916 Bonair Drive SW Seattle Date Application Expires: Date Application Accepted: ox(1,11 H:\ Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh City WA 98116 State Staff Initials: j Zip Page 6 of 6 Parcel No.: 3365901881 Permit Number: D09 -145 Address: 14220 INTERURBAN AV S TUICW Status: APPROVED Suite No: Applied Date: 07/22/2009 Applicant: B I, INC. Issue Date: Receipt No.: R09 -01268 Initials: JEM Payment Date: 08/13/2009 11:11 AM User ID: 1165 Balance: $0.00 Payee: BOYCE CONSTRUCTION INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 21232 251.90 Authorization No. ACCOUNT ITEM LIST: Description BUILDING - NONRES STATE BUILDING SURCHARGE • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http : / /www.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000/322.100 247.40 640.237.114 4.50 Total: $251.90 • Payment Amount: $251.90 PAYMENT RECEIVED doc: Receiot -06 Printed: 08 -13 -2009 Parcel No.: 3365901881 Permit Number: D09 -145 Address: 14220 INTERURBAN AV S TUKW Status: PENDING Suite No: Applied Date: 07/22/2009 Applicant: B I, INC. Issue Date: Receipt No.: R09 -01143 Initials: User ID: Payee: JEM 1165 DAVID E. KEHLE ARCHITECT TRANSACTION LIST: Type Method Descriptio Amount Payment Check 18661 160.81 Authorization No. ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000/345.830 160.81 Total: $160.81 Payment Amount: $160.81 Payment Date: 07/22/2009 11:25 AM Balance: $251.90 PAYMENT RECEIVED doc: Receipt -06 Printed: 07 -22 -2009 Pr %'ect:, _ 1 - _ 0. ..1 ll e. Type of Inspection: F-- I YV A+ Addrgss: I '-122.O 1 ^1-4e q t r bA Ni Date Called: Special Instructions: Date anted: as - o9 4. p.m. Requester: Phone No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ,ppproved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: 6 a or: I Rec i t No.: INSPECTION RECORD Regain a copy with permit 111.1 Jr Date: 'Date: .Dc - «Is PERMIT NO. _ O 5 .00 REINSPECTIO FEE REQJI RED. Prior to inspection, fee must be d at 6300 Southcent • r Blvd., uite 100. Call to schedule reinspection. COMMENTS: / TA) S7 v "f • Type of Inspection: .SOS • 6e< < < -Li A- PA C. -,4-rt 4 ( 5, &J; S` uA F-1 6)//-e__ cam - ,' J i1 ti 4 J Ie -e 4 ., A. e J e i d4 J L ( 4-f a-c ,L � ki: it/A-4 ) 1 4 V SLAJ P G 1 .I Project / 6 �i C�i1 �C- Type of Inspection: .SOS • 6e< < < -Li A- PA Addre s: 1 1 T1 0 7 Ju i -i Date Called: ' DO i , i A. /1 Special Instructions: Date Wanted: Oq Y- 21- I'll Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ❑ Approved per applicable codes. 601 -/45 PERMIT NO. (206)431 -3670 orrections required prior to approval. Date: ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Proj : `I`` H ct 1 ._.-. / /V� Type of Inspection: A <7,<_5;c,✓vAO 1 21 %s 1 Address: / 92.2 ....LA./ !?t, A e/ Date Called: '11 Special Instructions: Date Want d: ;rf r i Requester: Phone No: BOG -z ..- 33 9' ( o INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Approved per applicable codes. 'Corrections required prior to approval. COMMENTS: 4 S �r.nl/ G✓ -C dVS - A.40,1S, Ezer, /,- off _ (2.✓o/ 4 1.10 nspect Dat 60 0 REINSPECTION E REQUIff D. Prior to inspection, fee must be at 6300 Southcenter lvd., Suite 100. Call to schedule reinspection. R. - ipt No.: (Date: - Z COMMENTS: (j) �h'JO J — 6 -x', 1,1�,G S i c3W 1 C u✓ ii l sSlw F` ‘ A 51 (-- r) - 44 ( cA A ''PC.OcP.44 x• T .1 N.S 6Pr ¶ tv - vi / i& c l s--i I .'`1 G S E new «: c.N , Ss I'^'� P)(1 Si terrriaR MC'? Asklb , Dade Special Instructions: 8 to �t ulhc4 ow C'c % J • 1 Z. Date Wanted: r I-7- v5 ►( Kic, — Ney..,----) ,? R e q uester: hone No: Project: Q ,r ► 'Jc Type of Inspection: r2 /i iV 6, Address: / Z _1..J ir'/It i/6/ Date Called: Special Instructions: 8 to �t ulhc4 ow C'c % J • 1 Z. Date Wanted: r I-7- v5 a.m. R e q uester: hone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION IQ- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 EI Approved per applicable codes. ECorrections required prior to approval. nspe • rn $60 10 REINSPECTION EE REQUI ID. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ec- ipt No.: IDAte: ►7 - 7 Project: ✓ ` T. J- r► 4 _ `_ Y Type of Inspectiion: r P 4 �i 11 A 1 F1 , - e r 1• hc. 1 Address: / L/ } i c, ./,.1 Al) Suite #: / ice 0 S - i Contact Person: Special Instructions: /v Phone No.: Needs Shift Inspection: Y Sprinklers: Fire Alarm : • 'r A44_ ,.� I Hood & Duct: /v Monitor: 1„.,A- .4 in 1, Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY' OF TUKWILA FIRE DEPARTMENT PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 - 11Approved per applicable codes. Word /Inspection Record Form.Doc 1/13/06 Corrections required prior to approval. COMMENTS: FA F'► t 1/4( Gc ; ' F ; vk Inspector: Date: 5- --,,t5" - Hrs.: • n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 Project: $% Ned ,ZPtheA fir, Type of Inspection: 4 Address: / 1/0 .141 Suite #: /4,0 S Contact Person: - C 1 Special Instructions: Permits: Phone No.: Needs Shift Inspection: • Sprinklers: • Fire Alarm: Hood & Duct: Monitor: Pre -Fire: . Permits: Occupancy Type: INSPECTION NUMBER Inspector: 2. 1,-n1 5 INSPECTION RECORD Retain a copy with permit Word /Inspection Reco r Form .Doc 1/13/06 Dal -14 at - /21 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa: 98188 _ f 206 -575 -4407 I I Approved per applicable codes. Corrections required prior to approval. I COMMENTS: t t°re IN KL oz. n sik.z/ vAt2 — © -- GD(47?. LUwe i f "K .5 1'Pa�n 31 A 'T MoR219 Hrs.: I Datfi: g/ V n $80.00 REINSP CTTON FEE REQUIRED. You will receive an invoice from the City of Tukwila An nce Department. Cell to schedule a reinspection. T.F.D. Form F.P. 113 Project Info Project Address Date0 )n' W +414 i4'z ' i( t2J, I For Building epa tment Use Q yes Semi - Heated Path Q no Applicant Name: ID Vel it, _ v ` v a Applicant Address: p v144 'loft � A h?f Ito Applicant Phone: 4010 '43q •-T1. Space Heat Type Q Electric resistance *All other (see over for definitions) Glazing Area Calculation Note: Below grade walls may be included in the Gross Exterior Wall Area if they are insulated to the level required for opaque walls. Total Glazing Area Electronic version: these values are automatically taken from ENV -UA -1. (rough opening) Gross Exterior (vertical & overhd) divided by Wall Area times 100 equals % Glazing W +414 — X 1 00 = Concrete/Masonry Option 0 yes no Check here if using this option and if project meets all requirements for the Concrete/Masonry Option. See Decision Flowchart (over) for qualifications. Enter requirements for each qualifying assembly below. Q yes Semi - Heated Path Q no Check here if using semi - heated path and if project meets all requirements for semi- heated spaces as defined in section 1310. Requires other fuel heating and qualifying thermostat Only wall insulation requirement is reduced (2006 change). Only available in prescriptive path. 2006 Washington State Nonresidential Energy Code Compliance Form • rWm mw, -. — Envelope- Summary< l one 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Description ❑ New Building ❑ Addition *Iteration ❑ Change of Use Compliance Option ❑ Prescriptive ❑ Component Performance (See Decision Flowchart (over) for qualifications) ❑ Seattle EnvStd ❑ Systems Analysis Envelope Requirements (enter values as applicable) Minimum Insulation R- values Roofs Over Attic All Other Roofs Opaque Walls' Below Grade Walls Floors Over Unconditioned Space Slabs -on -Grade Radiant Floors Opaque Doors Vertical Glazing Overhead Glazing Maximum U- factors Maximum SHGC (or SC) Vertical /Overhead Glazing 1. Assemblies with.metal framing must comply with overall U- factors Notes: 1,10 V.146 latiL004 RECEIVED CITY OF TUK MLA JUL 2 2 2009 PERMIT CENTER Opaque Concrete /Masonry Wall Requirements Wall Maximum U- factor is 0.15 (R5.7 continuous ins) CMU block walls with insulated cores comply If project qualifies for Concrete /Masonry Option, list walls with HC ? 9.0 Btu /ft - °F below (other walls must meet Opaque Wall requirements). Use descriptions and values from Table 10 -9 in the Code. Wall Description U- factor (including insulation R -value & position) EnvelopeFSummay, I imateAZ one 2006 Washington State Nonresidential Energy Code Compliance Forms Decision flowchart for Prescriptive Option Use this flowchart to determine if project qualifies for the optional Prescriptive Option. If not, either the Component Performance or Systems Analysis Options must be used. 1302 Space Heat Type: For the purpose of determining building envelope requirements, the following two categories comprise all space heating types: Other. All other space heating systems including gas, solid fuel, oil, and propane space heating systems and those systems listed in the exception to electric resistance. (continued at right) .a--N All Insulation Instated? Below Grd Wall (ext) Below Grd Wall (oth) Roof Over Attic All Other Roof Raised Floor Slab -On -Grade Radiant Floor Opaque Door R -10 R -19 R -30 R -21 R -19 R -10 R -10 U -0.60 No Above Grade Wall R19 Mass Wall Criteria OK? (below) Yes • AG Mass Wall Insulation Req. Mass Wall U0.15 /R5.7ci CMU Block Ins. Cores Wood Frame R19 (I Metal Framed R19 r No • 2006 Washington State Nonresidential Energy Code Compliance Form Ly Glazing Criteria Met? Glazing Vert OH Area % UVal UVal SHGC 0-30% 0.55 0.70 0.45 30 -45% 0.45 0.60 0.40 >45% Not Allowed No • ( START �) � I i Yes Yes Glazing Area % 0 -30% >30 Prescriptive Path Allowed Component Performance, Systems Analysis, or EnvStd Required Electric Resistance: Space heating systems which use electric resistance elements as the primary heating system including baseboard, radiant, and forced air units where the total electric resistance heat capacity exceeds 1.0 W/ft of the gross conditioned floor area. Exception: Heat pumps and terminal electric resistance heating in variable air volume distribution systems. Yes Yes Glazing Criteria Met? I Yes All Insulation Installed? Wood Metal Below Grd Wall (ext) R -10 R -10 Below Grd Wall (oth) R -19 U -0.062 Roof Over Attic R -38 U -0.031 All Other Roof R -30 U -0.034 Raised Floor R -30 U -0.029 Slab -On -Grade R -10 R -10 Radiant Floor R -10 R -10 0 u Door U-0.60 U-0 60 Yes— Vert OH UVal UVaI SHGC 0.40 0.60 0.40 Not Allowed Yes • AG Mass Wall Insulation Req. Mass Wall U0.15 /R5.7ci CMU Block Ins. Cores Wood Frame R19 Metal Framed U0.062 No Concrete/Masonry Option* Assembly Description Wall Heat Capacity (HC) Assy.Tag HC** Totals Area (sf) Area weighted HC: divide total of (HC x area) by Total Area HC x Area Revised July 2007 No No+ if the area weighted heat capacity (HC) of the total above grade wall is a minimum of 9.0, the Concrete Masonry Option may be used. **For framed walls, assume HC =1.0 unless calculations are provided; for all other walls, use Section 1009. Project Info Project Address Date ID Allowed x Area ,A,� a li y i tZ VA) For Building epar rent Use i Applicant Name:176 Mi t Applicant Address: IA �v W apt W. eti Ociat VD . Q f� H f' Applicant Phone: Mb, 433 , bates* Project Description ❑ New Building ❑ Addition i',1, Alteration ❑ Plans Induded Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Prescriptive Q Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting Less than 60% of the fixtures new, installed wattage not increased, & space use not changed Location (floor /room no.) Occupancy Description Allowed Watts per ft " Area in ft Allowed x Area From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts ntial Energy Code Compliance Forms Maximum Allowed Lighting Wattage Proposed Lighting Wattage 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting. Summary. wstac 4ttt 11C11407 Revised July 2007 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts Watts Proposed Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting note section and exception number, and leave Watts /Fixture blank. Joanna Spencer - Re: BI Inc. TI @ 14220 Interurban Ave S. D09 -145 From: Bryan Still To: Joanna Spencer Date: 07/23/2009 10:01 AM Subject: Re: BI Inc. TI @ 14220 Interurban Ave S. D09 -145 CC: Han Kirkland They are current. RPPA on domestic current. Fire DCDA current. They do need to change FDC to storz connection it currently has dual 2 1/2" siamese. Irrigation DCVA current. Thanks Bryan »> Joanna Spencer 07/22/2009 3:14 PM »> Are they current on their backflows ? Thanks, Joanna PERMANENT FILE COPY Page 1 of 1 file: / /C:\Documents and Settings \joanna.TUKWILA\Local Settings \Temp\XPgrpwise \4A... 07/23/2009 ACTIVITY NUMBER: D09 -145 PROJECT NAME: B 1, INC. SITE ADDRESS: 14220 INTERURBAN AV S X Original Plan Submittal Response to Correction Letter # DATE: 07 -22 -09 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: b"1 'O Birfldm" g Division Public Work/ V "1 O PERMI7 COORD COPY PLAN REVIEW /ROUTING SLIP DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete TEr Comments: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 AM A AK isi--111-67 Fire Prevention Structural n Incomplete DUE DATE: 07 -23-09 Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required n No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 08-20-09 Approved ❑ Approved with Conditions n Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: sM ni14- Planning Division Permit Coordinator Not Applicable Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status BOYCEC *088Q0 BOYCE CONSTRUCTION CONSTRUCTION CONTRACTOR GENERAL UNUSED 11/20/1992 11/ 18/ 1994 ARCHIVED MBCON * *095PS M B CONSTRUCTION CONSTRUCTION CONTRACTOR GENERAL UNUSED 10/10/1991 10/4/1992 ARCHIVED Name Role Effective Date Expiration Date BOWELL, ROBERT Cancel Date 01/01/1980 Bond Amount BOWELL, SHERI 4 01/01/1980 178017C Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 DEVELOPERS SURETY Et INDEM CO 178017C 11/18/2001 Until Cancelled $12,000.00 12/07/2001 3 DEVELOPERS SURETY a 178017C 12/29/200011/18 /2001 $6,000.00 08/17/2001 Untitled Page Other Associated Licenses • • General /Specialty Contractor A business registered as a construction contractor with LEd to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company BOYCE CONSTRUCTION INC 2062648085 270 S HANFORD ST 109 SEATTLE WA 98134 KING Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601538339 ACTIVE BOYCECI066QQ CONSTRUCTION CONTRACTOR 11/18/1994 1/9/2010 GENERAL UNUSED Page 1 of 2 Business Owner Information Bond Information https://fortress.wa.gov/lni/bbip/Detail.aspx 08/13/2009 64 :9' 1 00.92 , Rive= Proi otion Easement X: C.R.N. 63563040 mama SETBACKS FROM THE MEAN NIGH want LNE ARE No UESS THAN 40 M.iai PERMITTED USES WITHIN THAT WY ARE GENERALLY RBCREA N NATURE OR FOR DIKE MANT@IANCE. N TIEA�EA 'BETWEEN 40' AND 100 FROM "(HELEN; i.au WATER Lj I DMfiiB ARE RESTRICTED TO WIN H4EN& RARmia p � AND LOApNQ ARE AU.OW. $G S82'941 -' 8 2.31 0.30 'EASEMENT FOR PUBLIC � RECREATIONAL, TRAI L,_ AND ��� • FACILITIES, RECORD NO. TREES CLI 9V 9803130434 /14514' 46111 • Sp .70 _... --� _ _ PATH HIGH WATER LINE OF LEFT BANK QF DUWA,MISH RIVER DATE OF SUPERIOR COURT CAUSE NQ. 81 -2- 05910 -4 *Kr TO MAKE CUTS AND FLLS K CRR 85 to ` 40 2 . 21'ss' , _ A! 1014.93' N,, ....L 0 , rot N.W. LINE OF RIyW NO. 5 RIGHT TO MAKE CUTS AND RLLS K.CRM. 6557639 0 • MI REPORT Sc TO TION (T .). 379'82?09 "E Z9.x' Ca if • S $6! 6a Z 4 e 19,64' . Z .. / 4 " 6120 and AVE S. RATTLE, WA 98116 40' WIDE) — . ORI NAL.PLATTED LEFT BANK OF IXAVAA9Wi Point of ,8eginn /ng ( Pgrcel :..:A. motif- 21' SETBACK. COULD POTENTIALLY BE COMMEND A : SECONDARY FRONT WITH A 125 SETBACK CONSULT aTY OF TUKIIIJ11MiCIPAL DODO seCipN 1e so la OWNER GREW RIVER CONST N�. 14062 INTERURBAN AVE V S. TIKMOLA WA 98188 ' BUILDING AND SITE STATISTICS 1. BUILDING CODE: 2. ZONING: 3. BUILDING AREA —A: 4. OCCUPANCY GROUP: 5. TYPE OF CONSTRUCTION: 6. TENANT AREA: 7. AREA OF CONSTRUCTION: 8. CONSTRUCTION VALUE: NO CHANGE TO FOOTPRINT OF BUILDING IBC 2006 W /STATE AMENDMENTS C/LI 20,200 SF B OCCUPANCY !!B SPRINKLERED 2,994 SF 1,500 SF $8,300 SEPARATE PERMITS ELECTRICAL, MECHANICAL, PLUMEING AND FIRE PROTECTION WILL BE UNDER SEPARATE PERMIT. LEGAL DESCRIPTION TAX PARCEL #336590188106 HILLMANS SEATTLE GARDEN TRS POR OF LOT 1 AND ALL OF LOTS 2 THRU 7 & POR ADJ IN SE 1/4 OF SECTION 14 -23 -94 DAF — BEG SE COR OF SAID LOT 7 TH NLY ALG ELY LN 315 FT TO LFT BANK OF DUWAMISH RIVER AS ORIGINALLY PLATTED TH CONTG ON NLY PROD OF SD ELY 220 FT M/L TO LFT BANK AS EXISTED UNDER SUPERIOR COURT CAUSE NO 81- 2- 05910 -4 TH WLY ALG SD BANK TO AN INTSN WITH MELY PROD OF SELY LN OF NWLY 72 FT OF SD LOT 1 TH SWLY ALG SD LN PROD 200 FT M/L TO LFT BANK OF DUWAMISH RIVER AS PLATTED IN ORIGINAL PLAT TH CONTG IN SWLY DIRECTION ALG SELY LN OF NWLY 72 FT OF SD LOT 1 DISTANCE OF 55 FT M/L TO SWLY LN OF SD LOT 1 TH SELY ALG SD LN TO INTSN WITH N MGN OF S 145RD ST FIRST AVE TH ELY ALG SD MGN TO TPOB -TGW POR FOSTER JOSEPH DC #39 BEING POR OF ABANDONED PUGET SOUND ELECTRIC RR RNV IN THE SW '/4 IF SE' SF RR R.W BOUNDED ON NE BY MAULE AVE ON SW BY A LN 20 FT NE OF & PLT NELY MGN OF SR 181 UNDER REC #8905231113 ON THE SE BY PJW #5 & ON THE NW BY RNV #6 BOTH R/W DEFINED IN QCD AUD FILE #6557639 — TGW VAC MAULE AVE ADJ. SCOPE OF WORK: INSTALL NEW NON - BEARING WALLS TO CREATE TWO NEW OFFICE AND LOBBY, DEMO EXISTING NON - BEARING WALLS, MODIFY LIGHTING, PER PLANS. NO CHANGES TO BUILDING ENVELOPE AND NO INCREASE IN WATTAGE VIA RELOCATION OF EXISTING LIGHTS. REVISIONS N o changes shall be made to the scope of work without prior approval of Tukwila Building Division. N OTE: Revisions will require a new plan submittal and may include additional plan review fees. I Permit No. FILE COPY Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: Date: _2 - ( 3'0`! City Of TUkwiia BUILDING DIVISION SEPARATE PERMIT REQUIRED FOR: Ei ctrica! n bing C 3as Piping City of Tukwila UI ...1 ING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 8 2009 4 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 2 2 2009 PERMIT CENTER PO°I - ICI 5 00 8 0 W F z 0 5%1 s < 4' C\ =1 \ \Wkst -4 \Documents \CAD \2009 \0908 FAIRWAY CENTER \BUILDING A \SUITE A 160 \TBOi(..dwg, 7/8/2009 11:32:00 AM, DesigNet 500 MAIN.pc3 SUITE A-160 A TENANT IMPROVEMENT FOR: DATE B 06 - 30 - 09 nnE ... _ DESCRIPTION 31da PUTS :<-..< 64 :9' 1 00.92 , Rive= Proi otion Easement X: C.R.N. 63563040 mama SETBACKS FROM THE MEAN NIGH want LNE ARE No UESS THAN 40 M.iai PERMITTED USES WITHIN THAT WY ARE GENERALLY RBCREA N NATURE OR FOR DIKE MANT@IANCE. N TIEA�EA 'BETWEEN 40' AND 100 FROM "(HELEN; i.au WATER Lj I DMfiiB ARE RESTRICTED TO WIN H4EN& RARmia p � AND LOApNQ ARE AU.OW. $G S82'941 -' 8 2.31 0.30 'EASEMENT FOR PUBLIC � RECREATIONAL, TRAI L,_ AND ��� • FACILITIES, RECORD NO. TREES CLI 9V 9803130434 /14514' 46111 • Sp .70 _... --� _ _ PATH HIGH WATER LINE OF LEFT BANK QF DUWA,MISH RIVER DATE OF SUPERIOR COURT CAUSE NQ. 81 -2- 05910 -4 *Kr TO MAKE CUTS AND FLLS K CRR 85 to ` 40 2 . 21'ss' , _ A! 1014.93' N,, ....L 0 , rot N.W. LINE OF RIyW NO. 5 RIGHT TO MAKE CUTS AND RLLS K.CRM. 6557639 0 • MI REPORT Sc TO TION (T .). 379'82?09 "E Z9.x' Ca if • S $6! 6a Z 4 e 19,64' . Z .. / 4 " 6120 and AVE S. RATTLE, WA 98116 40' WIDE) — . ORI NAL.PLATTED LEFT BANK OF IXAVAA9Wi Point of ,8eginn /ng ( Pgrcel :..:A. motif- 21' SETBACK. COULD POTENTIALLY BE COMMEND A : SECONDARY FRONT WITH A 125 SETBACK CONSULT aTY OF TUKIIIJ11MiCIPAL DODO seCipN 1e so la OWNER GREW RIVER CONST N�. 14062 INTERURBAN AVE V S. TIKMOLA WA 98188 ' BUILDING AND SITE STATISTICS 1. BUILDING CODE: 2. ZONING: 3. BUILDING AREA —A: 4. OCCUPANCY GROUP: 5. TYPE OF CONSTRUCTION: 6. TENANT AREA: 7. AREA OF CONSTRUCTION: 8. CONSTRUCTION VALUE: NO CHANGE TO FOOTPRINT OF BUILDING IBC 2006 W /STATE AMENDMENTS C/LI 20,200 SF B OCCUPANCY !!B SPRINKLERED 2,994 SF 1,500 SF $8,300 SEPARATE PERMITS ELECTRICAL, MECHANICAL, PLUMEING AND FIRE PROTECTION WILL BE UNDER SEPARATE PERMIT. LEGAL DESCRIPTION TAX PARCEL #336590188106 HILLMANS SEATTLE GARDEN TRS POR OF LOT 1 AND ALL OF LOTS 2 THRU 7 & POR ADJ IN SE 1/4 OF SECTION 14 -23 -94 DAF — BEG SE COR OF SAID LOT 7 TH NLY ALG ELY LN 315 FT TO LFT BANK OF DUWAMISH RIVER AS ORIGINALLY PLATTED TH CONTG ON NLY PROD OF SD ELY 220 FT M/L TO LFT BANK AS EXISTED UNDER SUPERIOR COURT CAUSE NO 81- 2- 05910 -4 TH WLY ALG SD BANK TO AN INTSN WITH MELY PROD OF SELY LN OF NWLY 72 FT OF SD LOT 1 TH SWLY ALG SD LN PROD 200 FT M/L TO LFT BANK OF DUWAMISH RIVER AS PLATTED IN ORIGINAL PLAT TH CONTG IN SWLY DIRECTION ALG SELY LN OF NWLY 72 FT OF SD LOT 1 DISTANCE OF 55 FT M/L TO SWLY LN OF SD LOT 1 TH SELY ALG SD LN TO INTSN WITH N MGN OF S 145RD ST FIRST AVE TH ELY ALG SD MGN TO TPOB -TGW POR FOSTER JOSEPH DC #39 BEING POR OF ABANDONED PUGET SOUND ELECTRIC RR RNV IN THE SW '/4 IF SE' SF RR R.W BOUNDED ON NE BY MAULE AVE ON SW BY A LN 20 FT NE OF & PLT NELY MGN OF SR 181 UNDER REC #8905231113 ON THE SE BY PJW #5 & ON THE NW BY RNV #6 BOTH R/W DEFINED IN QCD AUD FILE #6557639 — TGW VAC MAULE AVE ADJ. SCOPE OF WORK: INSTALL NEW NON - BEARING WALLS TO CREATE TWO NEW OFFICE AND LOBBY, DEMO EXISTING NON - BEARING WALLS, MODIFY LIGHTING, PER PLANS. NO CHANGES TO BUILDING ENVELOPE AND NO INCREASE IN WATTAGE VIA RELOCATION OF EXISTING LIGHTS. REVISIONS N o changes shall be made to the scope of work without prior approval of Tukwila Building Division. N OTE: Revisions will require a new plan submittal and may include additional plan review fees. I Permit No. FILE COPY Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: Date: _2 - ( 3'0`! City Of TUkwiia BUILDING DIVISION SEPARATE PERMIT REQUIRED FOR: Ei ctrica! n bing C 3as Piping City of Tukwila UI ...1 ING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 8 2009 4 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 2 2 2009 PERMIT CENTER PO°I - ICI 5 00 8 0 W F z 0 5%1 s < 4' C\ =1 \ \Wkst -4 \Documents \CAD \2009 \0908 FAIRWAY CENTER \BUILDING A \SUITE A 160 \TBOi(..dwg, 7/8/2009 11:32:00 AM, DesigNet 500 MAIN.pc3 SUITE A-160 A TENANT IMPROVEMENT FOR: VACANT 1,950 RSF COMMON CORRIDOR VACANT 3,306 RSF COMMON CORRIDOR ,4RE4 OF IMPROVEMENT SCALE: 1 /8 " =1 ' OVERALL FLOOR PLAN :BUIDLING A 4 Do°F- (L(g 9 PER SECTION ion-2 15UILDINCS WITH ONE EXIT, 1:3 OCCUPANCY, 49 ()CC. OR LESS MAX, TRAVEL DISTANCE IN 4 SPRINKLERED BUII,DINC (POOTNOE D) 15 100 LP. OUR OCCUPANT LOAC? IS 46 OGC. REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 8 2009 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 2 2 2009 PERMIT CENTER \ \Wkst -4 \Documents \CAR \2009 \0908 FAIRWAY CENTER \BUILDING A \SUITE A 160 \T- 1.T- 2.dwg, 7/21/2009 3;3 3 6 OO) co al 2 Fr) d N O O v u pf o w en Q 4 z O Li! co t� < r- VI O) W W E z P 0 gip s10 Sgt PROJECT 0908 DRAWN BY DAVE I 60-0S MVO CHECKED BY DAVID 31da NOI1d183S30 - SUISMIT FOR PERMIT 31Va ai 1 r dE ATTACH BOTTOM TRACK TO CONC. FLOOR W/ POWDER DRIVEN ANCHORS AT 24" O.C. HILTI OR APPROVED I" EMBED, 0.131" DIA. 2 1/2" RUBBER BASE 41 CARPET 22" WIDE SOUND BATTS EA. SIDE WALL SOUND WALL tit! ,.� WALL SECTION SCALE: 1 -1/2" = 1' -0" WOOD DOOR HOLLOW METAL DRY WALL FRAME 5/8" GYP. BD. BOTH SIDES STEEL STUDS INTERIOR DOOR JAM 3 SCALE: 1 -1/2" = 1' -0" COUNTER SECTION SCALE: 3/4" = 1 -0" ! FOR WALLS GREATER THAN 8'- 0" IN WIDTH WITHOUT AN INTERSECTING WALL, PROVIDE 12ga. WIRES SPLAYED 6 45 TO AN EYE SCREW 6 ROOF AND TOP OF WALL CONT. METAL TRIM. 5/8" GYP. BD. (TYPE 'X' 9 FIRE RATED WALLS.) ACOUSTICAL BLANKET m SOUND WALL. CAULK GYP. BD. TO FLOOR 6) ALL SOUND AND INSUL. WALLS –2 SECTION SECTION EX. SUSP. CEILING a GYP. BD. WRAPPED � OPENING — PLASTIC LAMINATE C FACES, TOP AND ED (INCLUDING RETURNS FRAME AND PLYWOQ EXPOSED WOOD) GYP. BD PAINTED W LL 1 1 M r lO '� � C► ITAIIIIML m ' �' o�� --..----....mu ow • -1-ffel Armwtmi mow 1 -- IIIa -�-, /MI , -, 1I 1' I II . Imp \I M.� 11 `l III I/ /I I a I I s• 1 II u' Ir I NI■0..■•■1 -CJ CE a OUNTER D ON 2X4 D (PAINT 45' -0" 30' -0" REFLECTED CEILINCa PLAN NORTH • SCALE: 1 /S" = 1' - 0" RIhOCATE 2 LIGHTS, NO CHANGE IN WATTAGE REPAIR EX. GRID, REPLACE TILE AS NECESSARY 225''0" 30' -0" REM L IGI– REL LIGI– / / 2 EXISTING S AND RELOCATE CATS 2 EXISTING 5 LEGEND '\T m cn ct� EX. COMMON CORRIDOR ICAL EX. TELE/ DATA NE - 11T SIGNS ■ EXISTING WALL NEW WALL PER SCHEDULE EXISTING WALL TO BE REMOVED ILLUMINATED EXIT SIGN AND PATHWAY LIGHT W/ BATTERY BACK -UP. NEW PATHWAY LIGHTING W/ BATTERY BACK -UP. COMMON CORRIDOR io NEW DOOR EXISTING DOOR EXISTING DOOR TO BE REMOVED I RELOCATED COMMON MEN ci CE CE EX. COMMON KITCHEN EX. CLOSET EX. OPEN OFFICE 2107 SF = 21 QCC. REPAIR EX. DOOR ELEC. COMMON WOMEN 2,994 RSF EX. OFFICE 74' -7 1/4" WALL TYPES i`dk'I 11 EX. CONFERENCE 287 SF = 19 OCC. REMOVE WALL FOR NEW DOOR REMOVE EX n EXIT SIGN REMOVE EX. WALL, REPAIR GRID EX. OFFICE TENANT FLOOiR PLAN SCALE: 1 /8" = 1'_/7111 SEE T -1 FOR EXIT TRAVEL, SINGLE EXIT TOTAL OCCUPANT LOAD IS 46 OCCUPANTS 0 OPENING SCHEDULE ROOM SCHEDULE 0 DOOR 5C14EDULE 33 33 EX. OFFICE COMMON WOMEN X. WINDOW TO REMAIN I NEW OFFICE 2 — REMOVE EX. WI INFILL WITH STU 31/2"x25 GA STUDS 24" O.C., 5/8" GU I5 EA. SIDE TO UNDERSIDE OF SP. ACOUSTICAL CEILING, PAINT. SOUND INSULATE WALLS 1 NEW 6' - 0" X 3' - 6" At +3' - 6" AFF, GYP. P. WRAPPED, FOR PLASTIC LAM. COUNTER INSTALL NEW LEVER HANDLE HARDWARE IN NEW DOORS. MAX. 1/2" THRESHOLDS 1 NEW 3'- 0 "X7' -0" SOLID CORE DOOR (MATCH EX.), WOOD FRAME (MATCH EX. INTERIOR), LEVER LOCK9ET W/ ELCETRIC STIKE (CONTROL AT COUNTER), CLOSER, SILENCER, WALL STOP. INSIDE HANDLE ALWAYS EXIT FREE. 23,4 NEW 3 0 "Xl' -0" SOLID CARE DOOR (MATCH EX.), WOOD FRAME (MATCH EX. INTERIOR), LEVER HANDLE LOCKSET, SILENCER WALL STOP, ENERGY CODE NOTES: 1. NO CHANGE TO EXISTING BUILDING ENVELOPE 2. LIGHTING CHANGES WILL BE RELOCATING NEW WITI-4 NO INCREASE IN WATTAGE. 3. SWITCHING WILL BE PER NEW ROOM AND NOTE TO EXCEED SO% OF A 20 AMP CIRCUIT GENERAL NOTES: 1. MODIFY EXISITNG HVAC (SEPERATE PERMIT) 2. MODIFY EXISTING LIGHTING AS REQUIRED 3. MODIFY EXISTING SPRINKLERS AS REQUIRED (SEPERATE PERMIT) 4. MATCH EXISTING FINISHES, DOORS, HARDWARE, PROVIDE NEW OUTLET AND MUD RING FOR PI –IONE 30' -0" cg r PRC OUT RI\ -I 45' -0" 30' -0" (5) 225' -0" N FLOOR: PATCH AND REPAIR CARPET THROUGH OUT SPACE WALLS: GWB, NEW PAINT NEW WALLS ONLY AND TOUCH UP (EE) CEILING: EXISTING SUSPENDED ACOUSTICAL CEILING TILE (NO CHANGE) 1 FLOOR: PATCH AND REPAIR CARPET, 4" RUBBER BASE WALLS: GWB, NEW PAINTED NEW WALLS (EE) CEILING: EXISTING SUSPENDED ACOUSTICAL CEILING TILE (NO CHANGE) 2,3 FLOOR: PATCH AND REPAIR CARPET AND RUBBER BASE WALLS: GWB, NEW PAINT NEW WALLS (EE) CEILING: EXISTING SUSPENDED ACOUSTICAL CEILING TILE (NO CHANGE) De- WALL IDE NEW ET AND MUD FOR PHONE 'Igo 1 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 8 2UU9 City of Tukwila BUILDING DIVISION ETC. RECEIVED CITY OF TIJKINILA JUL 2 2 1u1!4 PERMIT CENTER \ \Wkst =4 \Documents \CAD \2009 \0908 FAIRWAY CENTER \BUILDING A \SUITE A 160 \T- 1.T- 2.dwg, 7/21/2009 3: N Os CO 0 CO 0 d N 8 o W E'-+ z W 0 O z s a) C) SUITE A-160 FAIRWAY WASHINGTON AN INTERIOR ALTERATION FOR: