Loading...
HomeMy WebLinkAboutPermit PG09-144 - CARTERS RETAILCARTERS RETAIL INC 17250 SOUTHCENTER PY PGO9-144 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: City.f Tukwila 7888920020 17250 SOUTHCENTER PY TUKW CARTERS RETAIL, INC. 17250 SOUTHCENTER PY, STE 144 , TUKWILA WA WIG PROPERTIES LLC -SS 4811 134TH PL SE , BELLEVUE WA Contact Person: Name: CLAUDINE SIEDLER Address: 4811 134 PL SE , BELLEVUE WA Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /wwwci.tukwila.wa.us Contractor: Name: REYNOLDS CUSTOM PLUMBING LLC Address: 12621 230 STE , GRAHAM WA Contractor License No: R.EYNOCP972B 1 DESCRIPTION OF WORK: LANDLORD PORTION: INSTALL (2) SINKS, (1) MOP SINK, AND (2) WATER CLOSETS. Value of Plumbing /Gas Piping: Fees Collected: Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet doc: UPC -7/07 $8,000.00 $180.00 FIXTURE TYPE AND OUANTITY * * continued on next page ** PLUMBING /GAS PIPING PERMIT Permit Number: Issue Date: Permit Expires On: Phone: Phone: 425 641 -2044 Phone: 360 - 893 -5315 Expiration Date: 02/03/2011 PG09 -144 01/13/2010 07/12/2010 Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 0 Water heater and /or vent 0 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and/or water 0 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 0 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 0 Medical gas piping (6 +) inlets /outlets 0 3 Gas Piping 0 Gas piping outlets (0 -5) 0 2 Gas piping outlets (6 +) 0 PG09 -144 Printed: 01 -13 -2010 Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presu - to give aut ty to violate or cancel the provisions of any other state or local laws regulating construction or : performance of ,0 7 1 i.70 1 1. 1P am autho €d to sign and obtain this plumbing /gas piping permit. Signat -. Date: /� � Print N. e: doc: UPC -7/07 City "Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /wwwci.tukwila.wa.us Permit Number: PG09 -144 Issue Date: 01/13/2010 Permit Expires On: 07/12/2010 Date: HI This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PG09 -144 Printed: 01 -13 -2010 Parcel No.: 7888920020 Address: Suite No: Tenant: 1: ** *PLUMBING AND GAS PIPING * ** doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 17250 SOUTHCENTER PY TUKW CARTERS RETAIL, INC. PERMIT CONDITIONS * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. PG09 -144 ISSUED 12/14/2009 01/13/2010 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. PG09 -144 Printed: 01 -13 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signatur Print Name: doc: Cond -10/06 PG09 -144 Date: ordinances governing or local laws regulating Printed: 01 -13 -2010 Site Address: Tenant Name: Property Owners Name: Wig Properties LLC -SS Mailing Address: 4811 134th Place SE Name: Claudine Siedler Mailing Address: 4811 134th Place SE E -Mail Address: csiedler @wigproperties.com Company Name: Mailing Address: Company Name: Mailing Address: Contact Person: E -Mail Address: Mailing Address: 17250 Southcenter Pkwy, Tukwila, WA 98188 Carter's Retail, INc. CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 lutp://www.eitukwila. us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATIOT. King Co Assessor's Tax No.• 788892 - 0020 -07 Floor: 1 0 Yes ❑ ..No WA 98006 State Zip Suite Number: 144 Bellevue City New Tenant: Contact Person: E -Mail Address: Contractor Registration Number: Kenne - th b �►► ari 61 phi . no+ Day Telephone: (425) 641 -2044 Bellevue WA Contact Person: E -Mail Address: cAOC ipenn 0\or% pear) a OpV1l Fax Number: H:\ Applications\Forms- Applications On Line\2009 Applications \1-2009 - Permit Application.doc Revised: 1 -2009 hh City State Fax Number: (425) 865 -8648 �•- x "`-'' /A-ec- v4 /4 t A e coach -eat I State 98006 Zip Zip City Day Telephone: Fax Number: Expiration Date: City State Zip Day Telephone: /3 tea'cici -4 Fax Number: V4- -t-.45 NGI Company Name:. ‘`PeArl c.iernGot.,4-kno Sr\e" toy �y t 9 ''i �.. j � �,U�J � WC�.�"1/4'"� !, city s e: �� " t � , ' �' � C�`' C..�t��� Day Telephone: 1 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste 1Sinks i Urinals Water Closet y� (i Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and /or vent Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or alteration of water piping and/or water treatment equipment Repair or alteration of drainage or vent piping Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each additional medical gas inlets /outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other thin atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets PLUMBING AND GAS PIPIN PERMIT INFORMATION -- 206 - 431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: 1 _ Mailing Address: City State Zip Contact Person: Day Telephone: E - Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ eiCCO Scope of Work (please provide detailed information): Building Use (per Int'I Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Indicate type of plumbing fixtures and /or gas piping outlets being installed and the quantity below: f-kUP `3► H:\Applications \Forms- Applications On- Line\2009 Applications \I-2009 Permit Application.doc Revised: 1 -2009 bh Sewer: Page 5 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this. application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Manmohan K. Wig Mailing Address: 4811 134th Place SE I Date Application Accepted: 2-11A ItA H:\Applications \Forms - Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Date Application Expires: oceIH l�n Date: Day Telephone: (425) 747 -8540 Bellevue WA 98006 City State Zip Staff Initials: Page 6 of 6 Parcel No.: 7888920020 Permit Number: PG09 -144 Address: 17250 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 12/14/2009 Applicant: CARTERS RETAIL, INC. Issue Date: Receipt No.: R09 -02056 Initials: WER Payment Date: 12/29/2009 10:53 AM User ID: 1655 Balance: $0.00 Payee: WIG PROPERTIES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3785 155.75 Authorization No. ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES PLUMBING - NONRES RECEIPT Payment Amount: $155.75 Account Code Current Pmts 000.345.830 11.75 000.322.103.00.00 144.00 Total: $155.75 PAYME RECEIVE doc: Receiot -06 Printed: 12 -29 -2009 T al RECEIPT NO: R09 -01996 Initials: JEM User ID: 1165 Total Payment: 113.95 Payee: WIG PROPERTIES LLC -SS SET ID: S000001325 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member M09 -158 PG09 -144 TOTAL: ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES Cflk of Tukwila. Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: //www. ci. tukw ila. wa. us Amount 89.70 24.25 89.70 SET RECEIPT Payment Date: 12/14/2009 TRANSACTION LIST: Type Method Description Amount Payment Check 3774 113.95 TOTAL: 113.95 Account Code Current Pmts 000.345.830 TOTAL: 113.95 113.95 PAYMET RECFVED e Project: 7 ms ? ' 5 ,r ,- /A; Type of Inspection: r /v '1 /µ r'h , /47l.2 Address: / "172 U .5 Ctv -i°' J Date Called: Special Instructions: ate Wanted: a Requester: Phone _ t5 - 77 / ' or INSPECTION RECORD Retain a copy with permit INSP ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION • 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. U Corrections required prior to approval. / C , CO M MENTS: / ./P ;A/ / - /)/,i 6. Date: /0 0 REINSPECTION EE REQUIRE . Prior to inspection, fee must be d at 6300 Southcente Blvd., Suite 100. Call to schedule reinspection. Re " ipt No.: / Date: 'L COMMENTS: Type of Inspection: 6, -6 'd'Z Address: / 7250 Sd5/I`tioAdel Date Called:��, 4, j— 5 3 — (e)SG)—(02- 1 1r7 Special Instructions: ./ Date Wanted: / -- / c.) —/0 DG -J J Requester: k. _SJ (AL. .,. Phone No: 2 6 06- °z77 , �r _ n� , >1' \'k ` V ( It-- vK Project: 4 •,0s 'Q Type of Inspection: 6, -6 'd'Z Address: / 7250 Sd5/I`tioAdel Date Called:��, 4, j— Special Instructions: ./ Date Wanted: / -- / c.) —/0 a.m. Requester: Phone No: 2 6 06- °z77 01— /- - ' INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. ) CITY OF TUKWILA BUILDING DIVISION r2, 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. / -Q ' Ins ' ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paidat 6300 Southcenter Blvd., Suite 100. Call to schedte reinspection. Date: Receipt No.: 'Date: DPARTMEENNT_ S: q E E wilding Division P a Publ Wor s Vsic Complete Comments: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 ®ERMIT C r l� l , C Y q ���� PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG09 -144 DATE: 12 -14 -09 PROJECT NAME: CARTER'S RETAIL INC SITE ADDRESS: 17250 SOUTHCENTER PY, STE 144 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route /% Structural Review Required n REVIEWER'S INITIALS: ❑ Planning Division ❑ ❑ Permit Coordinator ❑ DUE DATE: 12 -15-09 No further Review Required ❑ DATE: DATE: Not Applicable DUE DATE: 01-12-10 Approved ❑ Approved with Conditions 141' Not Approved (attach comments) Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date Insurance GREAT Number Date Date Date Date Amount Date 3 CO OF AMER INS 7902865510468 02/08/2008 Until Cancelled $12,000.00 02/08/2008 NY GREAT 2 AMER INS CO OF 7902865510468 02/10/2004 n Cancelled 02/10/2008 $12,000.00 02/17 /2004 NY 1 INS CO B34230224 834230224 01 /13/2003 02/10/200401 /20/2004 $12,000.0001/21/2003 Name Role Effective Date Expiration Date REYNOLDS, WILLIAM D PARTNER /MEMBER 01/21/2003 Untitled Page General /Specialty Contractor A business registered as a construction contractor with L81 to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company REYNOLDS CUSTOM PLUMBING LLC 3608935315 12621 230TH ST E GRAHAM WA 98338 PIERCE Limited Liability Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602263754 ACTIVE REYNOCP972B1 CONSTRUCTION CONTRACTOR 1/21/2003 2/3/2011 GENERAL UNUSED Business Owner Information Bond Information Insurance Information • 0 Page 1 of 2 https: // fortress .wa.gov /lni/bbip/Detail.aspx 01/13/2010 Company Policy Effective Expiration Cancel Impaired Received Insurance Name Number Date Date Date Date Amount Date 7 COUNTRY AM9006488 10/16/200810/16 /2010 $1,000,000.0009 /21/2009 MUTUAL Untitled Page General /Specialty Contractor A business registered as a construction contractor with L81 to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company REYNOLDS CUSTOM PLUMBING LLC 3608935315 12621 230TH ST E GRAHAM WA 98338 PIERCE Limited Liability Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602263754 ACTIVE REYNOCP972B1 CONSTRUCTION CONTRACTOR 1/21/2003 2/3/2011 GENERAL UNUSED Business Owner Information Bond Information Insurance Information • 0 Page 1 of 2 https: // fortress .wa.gov /lni/bbip/Detail.aspx 01/13/2010 -RESPONSIBILITY SCHEDULE NOTES: a' CONS RUCT ON. ANY D SCREPANG ES SHALL BE REPORTED TO TENANT CONSTRUCT O PROJECT MANAGER. BEGINNING DESCRIPTION S.G. GARTERS LANDLORD DESCRIPTION G.G. GARTERS LANDLORG N/A DIVISION 01000 - GENERAL SUPPLY INSTALL SUPPLY INSTALL AS-IS BY LL REMARKS SUPPLY INSTALL SUPPLY INSTALL BY LL REMARKS LANDLORD BUILDING PERMIT SUBMITTAL • DIVISION 15000 - MECHANICAL LANDLORD BUILDING PLAN GHEGK FEES • HVAG EQUIPMENT "ROOF TOP" • LANDLORD BUILDING PERMIT FEES •• • ROOF WORK AND EQUIPMENT CURBS • I • TENANT BUILDING PERMIT SUBMITTAL BY TENANTS PERMIT VENDOR HVAG DISTRIBUTION, DUCTWORK TENANT BUILDING PLAN GHEGK FEES G.G. SHALL PICK UP PERMIT AND PERMIT FEES DIFFUSERS TENANT BUILDING PERMIT FEES • BUILDING PERMIT FEES EXHAUST FANS AND VENTING • DEMOLITION N/A STOCKROOM UNIT HEATER • • LANDLORD GLEAN -UP #I AT TURN -OVER • SMOKE DETECTORS • TENANT 6.G. FINAL CLEAN -UP #I AT TURN -OVER • • FIRE SPRINKLER MAIN • EXISTING TENANT G.G. FINAL GLEAN -UP #2 AT PRE - OPENING • • COORDINATE WITH STORE MANAGER SPRINKLER SYSTEM • EXISTING NEUTRAL PIERS AND MALL BULKHEAD EXISTING SPRINKLER SYSTEM MODIFICATIONS • OTHER PERMITS, FEES, INSURANCE • • PLUMBING FIXTURES (TOILET ROOMS) • TEMPORARY POWER • • IF REQUIRED DRINKING FOUNTAIN N/A TEMPORARY BARRICADES • • FOR STOREFRONT WORK WATER AND SEWER STUB • TEMPORARY BARRICADE GRAPHICS • SANITARY PIPING • TRASH REMOVAL/DISPOSAL AND DUMPSTERS • • DOMESTIC WATER PIPING • DUMPSTER AT TURNOVER • • G.G. TO EMPTY DUMPSTER PRIOR TO MERCHANDISE ARRIVAL '< ACCESS PANELS • FINAL INSPECTIONS AND CERTIFICATE OF OGGUPANGY • • COORDINATED WITH TENANTS ARCHIGTEGT : WATER HEATER • MOP SINK, MOP HANGER AND HOSE • DIVISION 16000 - ELECTRICAL DIVISION 03000 - CONCRETE WORK ELECTRICAL SERVICE CONDUIT TO TENANT SPACE • NEW SERVICE SEE ELECTRICAL DRAWINGS. CONCRETE TRENCH FOR NEW PLUMBING • • ELECTRICAL SERVICE • NEW SERVICE SEE ELECTRICAL DRAWINGS. CONCRETE TRENCH FOR GASHDESK POWER • • ELECTRICAL PANELS • NEW BY LANDLORD CONCRETE POUR BACK FOR LEAVE OUT • • TRANSFORMER • NEW BY LANDLORD FIRE ALARM SYSTEM • DIVISION 05000- METALS EMERGENCY LIGHTING • SEE LIGHT FIXTURE SCHEDULE DEMISING PARTITION FRAMING • • EXIT SIGNS • SEE LIGHT FIXTURE SCHEDULE, RETAIL AREA TO BE GLG MOUNTED DEMISING PARTITION FURRING N/A FLUORESCENT LIGHT FIXTURES • SEE LIGHT FIXTURE SCHEDULE TOILET ROOM WALL FRAMING • FLUORESCENT LAMPS • SEE LIGHT FIXTURE SCHEDULE STOCKROOM WALL FRAMING • ACCENT LIGHT FIXTURES • • SEE LIGHT FIXTURE SCHEDULE OFFICE WALL FRAMING • ACCENT LIGHT LAMPS • • SEE LIGHT FIXTURE SCHEDULE COLUMN ENCLOSURE FRAMING • THERMOSTATS • TENANT SPEC, LIGHTSTAT MODEL THE -POI MASONRY WALL METAL FURRING • EXISTING WIRING, CIRCUITING, RECEPTACLES, SWITCHES • ALL LANDLORD ITEMS SEE E -I AND E -2 WIRING, CIRCUITING, RECEPTACLES, SIN ITCHES • • ALL TENANT ITEMS SEE E -I AND E -2 WIRING AND CONNECTION OF GASHWRAP • • SEE ELECTRICAL DRAWING E -2 DIVISION 06000 - WOOD AND PLASTICS TIME CLOCK, FOR STOREFRONT SIGN • ROUGH CARPENTRY, TENANT WORK, • • ALL LOW VOLTAGE TELEPHONE AND DATA CAT -5 WIRING • • G.G. TO CONTRACT WITH COMM WORKS FOR INSTALL INTERIOR WOOD TRIM, TENANT WORK • • SHOPPER TRACK (J -BOX :# CONDUIT) • • BLOCKING (FIRE RETARDANT LUMBER 4 PLYWD) • • SHOPPER TRACK (GABLE) • • G.G. TO CONTRACT WITH COMM WORKS FOR INSTALL TELEPHONE CONDUIT AND PULL STRING WIRING • • EXISTING, G.G. TO RELOCATE IF REQUIRED TELEPHONE SERVICE • • G.G. TO COORDINATE WITH TENANT FOR PHONE SERVICE TENANT VENDORS: DIVISION 01000 - THERMAL 4 MOISTURE PROTECTION FIBERGLASS BATT INSULATION • • LIGHTING SPECIALTY STORE LIGHTING 35 INDUSTRIAL PARK RD. GENTERB GT Larry De Francesco (860) 167- 0110x204 WOOD FIXTURES LEIDEN CABINET COMPANY 2385 EDISON BOULEVARD TWINSBURS, OH 44087 M ike Ho Hopp (330) 425 -8555 LOCKS / A -OK SECURITY DOOR HDW. (877) 265 -2100 Carl �a- oksecurit g y AIR INFILTRATION BARRIER • EXISTING SEALANT AND CAULKING • • • BY NEW WORK GENERAL WHERE REQUIRED Y FIRE STOPPING • • WHERE ANY NEW REQUIRED ROOFING/FLASHING • WATERPROOF MEMBRANE "WET AREAS" N/A FLOORING SGS FLOORING SYSTEM 530 S. MAIN ST. SUITE 110 O RANGE, GA 012868 BARRY SCHWARTZ (714) 542 -2146 SIGNS IMAGE CONSULTING SERVICES 1115 Donwell S. Euclid, OH 44121 Patrick O'Dea (440) 0151 -gg101 LOW VOLTAGE GOMM- WORKS, LLG CONTRACTOR 3550 ANNAPOLIS LAND N. PLYMOUTH, MN 55441 Tel. 136- 852 -3100 DIVISION 08000 -- DOORS 4 WINDOWS STOREFRONT ENTRY DOORS • STOREFRONT ALUMINUM FRAMING AND GLASS • INTERIOR DOORS, FRAMES. • SEE DOOR SCHEDULE, p PROJECT DATA / DIRECTORY' INTERIOR DOOR LEVER SETS • • • SEE DOOR SCHEDULE, PROJECT NAME: CARTERS, SPACE NO 144 SQUARE PKWY WA .18188 CLOTHING STORE APPAREL SIEDLER LLG PLACE SE wA gSOO6 RETAIL DRIVE LAG, WI 54135 Schainske Manager 332 -0420 PROJECT COORDINATOR: DON KAMM REAR SERVICE DOOR, FRAME 4 HARDWARE • SEE DOOR SCHEDULE, REAR SERVICE DOOR EXIT DEVICE SYSTEM • • SEE DOOR SCHEDULE, AOUTHGENTER 17250 SOUTHCENTER TUKWILA, PROJECT DESCRIPTION: CHILDRENS GADD TECH 225 Oakland Rd., Suite 105 South Windsor, GT 06014 Tel. (860) 183 -5610 TENANTS ARCHITECT: KENNETH L. BUTTS, ARCHITECT A -OK SECURITY LOCKS AND GORES • • SEE DOOR SCHEDULE DIVISION 0 - FINISHES AND RELATED TENANT COORDINATOR: CLAUDINE CEILING SUSPENSION SYSTEMS • 124 STAGE COACH ROAD BELL CANYON, GA 011301 TEL (818) qqq-4212 FAX: (818) - .1.101 -4321 TENANTS ENGINEER: DONN PENN, CONSULTING ENGINEER ACOUSTICAL TILES (SALES) • WIG PROPERTIES 4811 -154TH BELLEVUE, TENANT: CARTERS ACOUSTICAL TILES (NON - SALES) • GYP. BD. CEILING (SALES) N/A GYPSUM WALL BOARD (DEMISING PARTITION) • • BUILDING DEPT.: 635 WESTPORT PARKWAY, SUITE 300 ' GRAPEVINE, TEXAS 16051 Tel. '811 -410 -2858 DEPARTMENT OF COMMUNITY DEVELOPMENT 6300 SOUTHCENTER CLVD, #100 TUKWILA, WA .18188 ATT: BUILDING OFFICIAL (206) 431 -3655 GYPSUM WALL BOARD (H G TOILET ROOM PARTITIONS) • GYPSUM WALL BOARD (STOCK ROOM PARTITION) • GYPSUM WALL BOARD (COLUMN ENCLOSURES) • • W5161 KENNEDY FOND DU Ms. Brenda Project TEL (120) GYPSUM WALL BOARD (OFFICE /HALL) • GYPSUM WALL BOARD (MOP SINK AREA) • SALES AREA FLOORING • • SHEET VINYL FLOORING (TOILET ROOM) • VGT (OFFICE /STOCK /HALL) • WALL BASE (SALES) • • CODE SUMMARY VINYL BASE (OFFICE /STOCK /HALL) • REDUCER STRIPS, ADHESIVE, ETC. • • APPLICABLE CODES. BUILDING CODE: 2006 International Building Code - Chapter 51 -50 WAG MECHANICAL CODE: 2006 International Mechanical Code (IMG 06)- Chapter PLUMBING CODE: 2006 Uniform Plumbing Code (Chapters 51 -56 and 51 ELECTRICAL CODE: 2008 National Electrical Code (NFPA 10) ENERGY CODE: 2006 Washington State Energy Code- Chapter 51 -I1 ACCESSIBILITY: 2 003 IGG /ANSI All1.l CHAPTER 10 MEANS OF EGRESS OCCUPANCY CALCULATIONS: TABLE 1004.1.1 ROOM OCCUPANT OCCUPANT 2 EXITS ROOM DESCRIPTION AREA FACTOR LOAD REQUIRED BUILDING DATA USE GROUP: (M Met 51 -52 WAG CONSTRUCTION TYPE: LIB -51 WAG) GROSS FLOOR AREA 4,000 S.F. WAG OCCUPANCY ' LOAD: 112 = SPRINKLER Yes NFPA I.. FIRE ALARM: Yes NFPA -7 FIRE EXTINGUISHERS: Yes NFPA MINIMUM PLUMBING FIXTURES (EXISTING) 2006 UNIFORM PLUMBING CODE, CHAPTER 4 412.5 Facilities In Mercantile and Business Occupancies Se TABLE "A" OCCUPANT LOAD FACTOR GROUP "M" 200 / 4000 S.F. = 20 PERSONS 10 MALE / 10 FEMALE TABLE 4 -I RETAIL OR WHOLESALE STORES WATER CLOSET: MALE 1:1 PROVIDED FEMALE 1:1-25 PROVIDED I LAVATORY: ONE FOR EVERY TWO WATER CLOS ETS PROVIDED MALE PROVIDED FEMALE : I DRINKING FOUNTAINS: 0:1 -30 NOT REQUIRED SERVICE SINK: NOT REQUIRED PROVIDED: FLOOR PREP, INCLUDING LEVELING • • • FLOOR PROTECTION • • • PAINTING, FINISHING SALES AREA • PAINTING, FINISHING NON -SALES AREA • CORNER GUARDS • • SEE SHEET AI.2 FOR SPECIFICATION DIVISION 10000 SPECIALTIES STOREFRONT ILLUMINATED SIGNS • • TENANT SIGN CONTRACTOR ' BLADE SIGN • • TENANT SIGN CONTRACTOR INTERIOR SIGNS LOGO SIGNS • • INTERIOR GRAPHICS BY TENANT VENDOR "COMING SOON" SIGN • • INTERIOR GRAPHICS BY TENANT VENDOR EMPLOYMENT "NOW HIRING" SIGNS • • TOILET ACCESSORIES (OTHER THAN NOTED BELOW) • TOILET ACCESSORIES : PAPER TOWEL HOLDER, • • LANDLORD TO INSTALL TOILET PAPER HOLDER, SOAP DISP. STORAGE CABINET • • LANDLORD TO INSTALL KOALA CHANGING STATION • • TOILET ROOM UTILITY CABINET • • LANDLORD TO INSTALL H.G. GRAB BARS • ACCESSIBILITY S1GNAGE • • WHERE REQUIRED 100 SALES AREA 3301 S.F. 30 110 YE5 101 HALLWAY 108 S.F. 0 0 NO 102 H.G. TOILET ROOM WOMENS 58 S.F. 0 0 NO 103 H.G. TOILET ROOM MENS 64 S.F. 0 0 NO 104 OFFICE 13 S.F. 100 I NO 105 STOCK ROOM 3q6 S.F. 300 2 NO FIRE EXTINGUISHERS • • DIVISION 11000 - EQUIPMENT SHOPPER TRACK • • INSTALL BY TENANT VENDOR SECURITY SYSTEM • • • G.G. TO COORDINATE WITH CHECKPOINT PO5 EQUIPMENT "CASH REGISTERS" • • • INSTALL BY TENANT VENDOR GOMM WORKS, CONTRACTED BY G.G. COMPUTER SYSTEMS • • • INSTALL BY TENANT VENDOR GOMM WORKS, CONTRACTED BY G.G. TOTAL: 4,000 S.F. 112 YES REFRIGERATOR / MICROWAVE / LOCKERS / BREAK TABLE • • SAFE • • BOLT TO FLOOR WITH EXPANSION ANCHORS EGRESS WIDTH PER OCCUPANT: TABLE 1005.1 INCHES PER PERSON = 11 INCHES (REQUIRED) FRONT: DOORS = 66" CLEAR REAR: = 34" CLEAR =102" CLEAR Exception #2 Not located less than dimension of the area being served. AUDIO EQUIPMENT AND SPEAKERS • • INSTALL BY TENANT VENDOR I.) EGRESS COMPONENTS (WITH SPRINKLERS) 0.15 INCHES PER OCCUPANT x 112 OCCUPANTS 2.) ACTUAL WIDTH PROVIDED THROUGH THROUGH FRONT AREA (PAIR 3' -0:" 3 ACTUAL WIDTH PROVIDED THROUGH THROUGH REAR (I) 3' -0" DOOR TOTAL EGRESS WIDTH' PROVIDED: 1015.2.1 TWO EXIT ACCESS DOORWAYS: one third of the overall diagonal DIVISION 12000 - FURNISHINGS GASHDESK • • FLOOR FIXTURES • • SURFACE MOUNT WALL STANDARDS • • HARDWARE AND BRACKETS FOR STANDARDS • • ROLLING SAFETY LADDER • • HARDARE STORAGE UNIT W • • OFFICE COUNTERS • • 1016.1 MAXIMUM TRAVEL: 250 feet sprinklered 10I .1.1 MINIMUM NUMBER OF EXITS: I -500 Occupants / 2 Exits required 5 O PROJECT PROJECT KEY PLAN GARTERS SOUTHCENTER SQUARE TUKIAIILA, WA Gf&ISS SPACE NO. 144 SEPARATE PERMIT REQUIRED FOR: 4 ethan k:al Electrical ❑ Plumbing ❑ Gas Piping City of Tukwila S I DING DIVISION rving Customers PROVIDED 2 carter' babies and kids SOUTHCENTER SQUARE 17250 SOUTHCENTER PKWY TUKWILA, WA AREA: 4,000 SQ/FT TENANT SPACE No. 144 YOAL; Oa* . 1 r� 49111# N C t Y 5 � :N KottS-EirifiN DRAWING INDEX ARCHITECTURAL GI.I GI.2 M.E.P. ENGINEERING L Permit No. Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize Vol violation of any adopted code or ordina Receipt of approved Fii Id Copy a loons is owledged: /!3 /told City Of Tiukwila BUILDING DIVISION No changes shall be ONS made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions win require a new plan submittal and may include additional plan revir -.tnr fry ^, RESPONSIBILITY SCHEDULE, PROJECT TITLE, INDEX, KEY PLAN, DATA DOOR SCHEDULE, DOOR TYPES AND DOOR HARDWARE, GENERAL CONTRACTOR NOTES A0.1 LEASEOUTL I NE FLOOR AND STRUCTURE PLAN AI.I CONSTRUCTION PLAN (LANDLORD WORK) A I.2 FLOOR FINISH PLAN / FINISH SCHEDULE / ROOM FINISH SCHEDULE A I.3 WALL STANDARDS ` INSTALLATION PLAN AI.4 FLOOR FIXTURING / MILLWORK PLAN A2.I REFLECTED CEILING PLAN A3.I STOREFRONT ELEVATIONS, DETAILS, EXTERIOR SIGNS A3.2 SALES AREA, ELEVATIONS, KEY PLAN A5.3 TOILET ROOM, PART PLAN Et ELEVATIONS A3.4 STOCKROOM OFFICE, PART PLAN, ELEVATIONS A4.I INTERIOR SECTIONS AND DETAILS A4.2 INTERIOR SECTIONS AND DETAILS A5.1 STOCKROOM SHELVING DETAILS A6.I ROOF PLAN / HVAG UNIT INSTALLATION El FLOOR PLAN LIGHTING WORK E2 FLOOR PLAN - MISC. ELECTRICAL WORK E3 ELECTRICAL DETAILS E4 LOW VOLTAGE DIAGRAMS E5 ELECTRICAL SPECIFICATIONS MI FLOOR PLAN - MECHANICAL WORK M2 MECHANICAL SPECIFICATIONS PI FLOOR PLAN PLUMBING WORK REVIEWED F R CODE COMPLIANCE APPROVED DEC 2 2 2009 A-r City of Tukwila - BUILDING DIVISION CIT OF U DEC 14 2009 PERMIT CENTER DATE: 11/I5/09 JOB NO: 09 -066 DRAWN: STA P CHECKED: KB 3405 (ADDTzri D• E S• 1 • G• N 215 OAJCLAND RAOD, SURE 105 TEL: (860) 183 -5610 ECM WINDSOR, CT 0(2014 FAX: (860)183 -5680 W CC cc W pig O z c'o CO woo CC ° W=Qd- Z� • WpQ O T O w 1 - 0 V � N aj o_ t`z.1.-- co KENNETH L. BUTTS ARCHITECT AIA 124 STAGECOACH ROAD BELL CANYON, CA 91307 (818) 999 -4272 KlNNETH L. BUTTS STATE OF WASHINGTON STORE NUMBER %TBD REVISIONS ISSUE: LANDLORD COMMENTS DATE: 12/1/09 'B' -ISSUE DATE 'C' - ISSUE DATE 'D'- ISSUE DATE z SHE SHEET SCALE NONE REGISTERED ARCHITECT. N C A :a SHEET NUMBER 3/4 "_ WC 2" CW 72" CW 1/2" HW EXPANSION TANK CW 7 - /2" /CW 1/27 HW ` 11/2" CW 1/2" HW -NEW 6 GALLON WATER HEATER ON WALL ABOVE MOP SINK COLD WATER PIPING TO SPACE BY LANDLORD NEW COLD WATER PIPING IN SPACE CAPPED BY LANDLORD - CONNECT NEW PIPING TO TOILET ROOMS IN SPACE AS REQUIRED PART PLANS SCALE. 1/4• - r-o• NEW COLD WATER PIPING IN SPACE CAPPED BY LANDLORD - CONNECT NEW PIPING TO TOILET ROOMS IN SPACE AS REQUIRED 3/4" 3/4" EXPANSION TANK 1/2" ALL PLUMBING IS BY THE LANDLORD AND IS SHOWN FOR INFORMATION ONLY ALL PLUMBING IS BY THE LANDLORD AND IS SHOWN FOR INFORMATION ONLY MOP SINK WATER PIPING DIAGRAM NOT TO SCALE PLUMBING WORK DRAIN PAN RELIEF VALVE - WATER HEATER ON WALL ABOVE MOP SINK 1" DRAIN DOWN TO MOP SINK WITH APPROVED AIR GAP \ti\ Z NEW 4" SANITARY PIPE CAPED IN SPACE - CONNECT NEW PIPE AS REQUIRED. NEW 4" SANITARY PIPE TO SPACE BY LANDLORD NEW 4" VTR THROUGH FLOOR (TYPICAL) W.C. J ALL PLUMBING IS BY THE LANDLORD AND IS SHOWN FOR INFORMATION ONLY 1 1/2" NEW 4" SANITARY PIPE TO SPACE BY LANDLORD -0 » 1 1/2" MOP SINK NEW 4" SANITARY PIPE CAPED IN SPACE - CONNECT NEW PIPE AS REQUIRED. WASTE AND VENT PIPING DIAGRAM NOT TO SCALE PLUMBING EQUIPMENT AND MATERIAL LAVATORIES: AMERICAN STANDARD #0124.024 "COMRADE', 20" X 18", WITH #2385.049 FAUCET, SUPPLIES, STOPS, DRAIN, P_TRAP AND WALL HANGER. WATER CLOSETS: TOTO #CST744SL -ADA "DRAKE", 16.5" HIGH, FLOOR MOUNTED, 1.6 GPM FLUSH, WITH SUPPLY, STOP AND WHITE OPEN FRONT SEAT, LESS COVER. MOP SINK: MUSTEE #63M, FLOOR MOUNTED, 24" X 24 ", COMPLETE WITH INTEGRAL 3" BRASS DRAIN, STAINLESS STEEL DOME WITH STRAINER AND SCREWS AND #8344.112 AMERICAN STANDARD FAUCET WITH TOP BRACE, STOPS AND VACUUM BREAKER. BOTTLE WATER COOLER: GE #GXCF25HBS, 5 GALLON BOTTLE OR EQUAL WATER HEATER: STATE #LDE- 6 -10MS, ELECTRIC, 16 GPH ® 100o RISE, 6 GALLON STORAGE, 1,650 WATTS, 120 VOLT, 1 PH, 60 HZ. EXPANSION TANK: STATE, MODEL ETC -2X, COMPLETE WITH TANK FITTING AS REQUIRED. PIPING MATERIALS: DOMESTIC WATER: TYPE L HARD TEMPER COPPER WITH WROUGHT SWEAT FITTINGS. WASTE & VENT: STANDARD WEIGHT CAST IRON WITH HUB AND SPIGOT FITTINGS. PIPE INSULATION: DOMESTIC WATER: 1" THICK, 3/4 LB. DENSITY FIBERGLASS WITH VAPOR BARRIER JACKET. PLUMBING WORK NOTES 1. ENTIRE INSTALLATION SHALL BE MADE IN STRICT ACCORDANCE WITH LANDLORD'S REQUIREMENTS. 2. THE SPACE IS NEW AND HAS NOT PREVIOUSLY BEEN OCCUPIED. REMOVE ALL EQUIPMENT, PIPING, ETC., IN THE SPACE PRESENTLY AND NOT REQUIRED FOR THE NEW INSTALLATION. 3. TWO (2) NEW TOILET ROOMS SHALL BE CONSTRUCTED. FURNISH AND INSTALL NEW PLUMBING FIXTURES, INCLUDING LAVATORIES, WATER CLOSETS, FLOOR DRAINS, ETC., IN THE LOCATIONS SHOWN. CONNECT WATER AND WASTE PIPING TO EXISTING LANDLORD PROVIDED PIPING IN SPACE AND EXTEND TO NEW FIXTURE LOCATIONS. EXTEND NEW VENT PIPE UP THROUGH ROOF. VERIFY EXACT LOCATION OF ALL STUBS AND LENGTH OF NEW PIPING REQUIRED IN FIELD PRIOR TO BID. BASE BID SHALL INCLUDE ALL PIPING NECESSARY FOR A COMPLETE INSTALLATION AND CONNECTION TO ALL PROVIDED STUBS. 4. FURNISH AND INSTALL NEW WATER HEATER THAT WILL BE MOUNTED ON THE WALL ABOVE THE MOP SINK IN ACCORDANCE WITH THE DETAIL ON THE DRAWING - WATER HEATER SHALL NOT BE MOUNTED OR SUPPORTED BY DEMISING WALL, THIS WILL NOT BE ACCEPTED. NEW WATER: HEATER SHALL BE MOUNTED IN A GALVANIZED DRAIN PAN, 6" DEEP. PRESSURE/TEMPERATURE RELIEF VALVE AND THE DRAIN PAN SHALL BE PIPED TO THE MOP SINK WITH APPROVED AIR GAP AS REQUIRED. 5. CUT AND PATCH THE FLOOR TO INSTALL NEW WASTE PIPING, AS REQUIRED. » CO PLUMBING WORK NOTES - GENERAL 1 LANDLORD WORK UNDER LANDLORD PERMIT REMOVED FLOOR DRAINS AND CORRECTED WATER HEATER INSTALLATION NOTES /SCOPE 1. PLUMBING WORK SHALL BE COMPLETE IN EVERY DETAIL AND ALL MISCELLANEOUS ITEMS OF MATERIAL AND LABOR NECESSARY TO COMPLETE THE WORK DESCRIBED, SHOWN OR REASONABLY IMPLIED ON DRAWINGS OR SPECIFICATIONS SHALL BE INCLUDED IN THE CONTRACT. CONTRACTOR SHALL MAKE MINOR ADJUSTMENTS TO THE WORK WHERE REQUESTED BY THE TENANT, WHEN SUCH ADJUSTMENTS ARE NECESSARY TO PROPER OPERATION AND WITHIN THE INTENT OF THE CONTRACT. 2. PLUMBING CONTRACTOR SHALL VISIT THE SITE AND VIEW ALL EXISTING CONDITIONS BEFORE SUBMITTING A PROPOSAL FOR THE WORK AS DESCRIBED AND SHOWN. NO EXTRAS WILL BE ENTERTAINED FOR FAILURE TO MAKE THIS VISIT. 3. PLUMBING CONTRACTOR SHALL ACCEPT SOLE AND COMPLETE RESPONSIBILITY FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. 4. CONFORM TO GENERAL CONTRACTOR'S SCHEDULE AND INSTRUCTIONS THROUGHOUT THE DURATION OF THE PROJECT AS REQUIRED TO COMPLY IN EVERY WAY NECESSARY. 5. CONTRACTOR SHALL NOTIFY THE ARCHITECT AND /OR ENGINEER OF ERRORS, OMMISSIONS OR DISCREPENCIES BEFORE CONSTRUCTION OR FABRICATION OF AFFECTED WORK, OR, FAILING SUCH NOTICE, ; SHALL BE RESPONSIBLE FOR CORRECTING SAME WITHOUT COST TO TENANT, ARCHITECT OR ENGINEER. 6. ORDER EQUIPMENT ON A TIMELY BASIS (WITHIN 5 DAYS OF RECEIPT OF CONTRACT) TO MAINTAIN CONSTRUCTION SCHEDULE. 7. SUBMIT FIVE (5) COPIES OF SHOP DRAWINGS OF ALL EQUIPMENT FOR REVIEW BY THE ENGINEER /ARCHITECT. ONE (1) COPIES WILL BE RETAINED FOR RECORD. ONLY FURNISH SYSTEMS, EQUIPMENT AND MATERIAL IN COMPLIANCE WITH APPROVED SHOP DRAWINGS. 8. WORK SHALL INCLUDE STARTUP OF ALL SYSTEMS, FURNISHING OF OPERATING AND MAINTENANCE INSTRUCTIONS, WARRANTEE FOR ALL EQUIPMENT AND ONE YEAR GUARANTEE OF ALL WORKMANSHIP, COMMENCING ON DATE OF ACCEPTANCE BY THE TENANT. 9. WORK SHALL ALSO INCLUDE FULL ONE (1) YEAR MAINTENANCE, PARTS AND SERVICE CONTRACT FOR ALL EQUIPMENT FURNISHED UNDER THE CONTRACT. 10.FURNISH ALL EQUIPMENT MANUALS AND WARRANTIES TO TENANT AT THE COMPLETION OF THE PROJECT. 11.WHERE APPLICABLE, FURNISH AND INSTALL VIBRATION ISOLATION AS REQUIRED TO REDUCE, LIMIT OR REMOVE ALL VIBRATIONS FOR ALL MOVING EQUIPMENT. VIBRATION ISOLATION SHALL BE IN ACCORDANCE WITH ASHRAE RECOMMENDATIONS. 12.ALL WORK AND EQUIPMENT SHALL BE CLEANED TO THE SATISFACTION OF THE OWNER BEFORE TURNING PROJECT OVER TO THE OWNER. 13.SEAL ALL PENETRATIONS THROUGH WALLS, CEILINGS, FLOORS, ETC. SO THAT THEY ARE AIR, WATER AND FIRE TIGHT. 14.FURNISH AND INSTALL ACCESS PANELS FOR ALL CONCEALED EQUIPMENT, FIRE DAMPERS, PIPING VALVES, CLEANOUTS, ETC. ACCESS PANELS SHALL BE OF SUFFICIENT SIZE TO PROVIDE ADEQUATE WORKING CLEARANCE AND ACCESS. 15.PROVIDE SHUT OFF VALVES IN THE SUPPLY PIPING TO EACH FIXTURE. FURNISH AND INSTALL AN ACCESSIBLE SERVICE VALVE ON ALL BRANCH PIPING. 16.FURNISH AND INSTALL CHAMBER SHOCK ABSORBERS AS SHOWN TO PREVENT NOISE AND DAMAGE DUE TO WATER HAMMER. 17.FURNISH AND INSTALL PRESSURE REGULATOR ON THE INCOMING WATER SERVICE IF SERVICE PRESSURE EXCEEDS 80 PSI. EXPANSION TANK (AMTROL MODEL AST -5 COMPLETE WITH ALL FITTINGS FOR A COMPLETE INSTALLATION) GATE VALVE - 4 4 (TYPICAL) CW 3/4" 3/4" T & P RELIEF VALVE 3 REFER TO ARCHITECTURAL DRAWINGS SHEET A4.1 DETAIL 8 FOR INSTALLATION SPECIFICS, ETC. 18.FURNISH AND INSTALL ALL PIPE HANGERS, CARRIERS, SADDLES, AND SUPPPOTS TO PROPERLY SUPPORT AND PROTECT ALL PIPING IN THE SPACE AS REQUIRED. HANGERS FOR HORIZONTAL PIPING WHERE PIPING IS TO BE INSULATED BE LARGE ENOUGH TO PASS INSULATION AND SHALL BE ELCEN FIG. 12 CLEVIS TYPE, WITH MEANS FOR VERTICAL ADJUSTMENT. INSTALL HANGERS AS FOLLOWS: PIPE SIZE HANGER ROD SIZE MAXIMUM SPACING 1/2" TO 1" 1- 1/4 "TO2" 3/8" 8' -0" O.C. 3/8" 10' -0" O.C. 2-1/2" AND ABOVE 1/2" 10' -0" O.C. 19.VERIFY LOCATION, DEPTH AND SIZE OF EXISTING SANITARY SEWER AT SITE. CONNECT AS REQUIRED. SEWER SHALL BE INSTALLED WITH 1/4" PITCH PER FOOT AND OUTSIDE SEWER SHALL BE INSTALLED WITH MINIMUM OF 3' -0" COVER. 20.FURNISH ALL EQUIPMENT MANUALS AND WARRANTIES TO TENANT AT THE COMPLETION OF THE PROJECT. 21.ALL WORK AND EQUIPMENT SHALL BE CLEANED TO THE SATISFACTION OF THE OWNER BEFORE TURNING PROJECT OVER TO THE OWNER. 22.FURNISH AND INSTALL TRAP PRIMERS ON ALL FLOOR DRAINS. 23.FURNISH ALL MATERIAL AND EQUIPMENT AS SPECIFIED, EXCEPT WHERE SPECIFIC APPROVAL FOR SUBSTITUTION IS GIVEN BY THE TENANT. 24.PROPOSAL SHALL BE BASED ON SPECIFIED MATERIAL AND EQUIPMENT. IN ORDER TO PROMOTE COMPETITION, HOWEVER, BIDDERS ARE ENCOURAGED TO SUBMIT ALTERNATE PROPOSALS ON ANY ALTERNATE MATERIALS AND /OR EQUIPMENT THEY WISH TO PROPOSE, INCLUDING ANY PRICE CHANGES EFFECTED BY ACCEPTANCE OF ALTERNATES. 25.COST OF ANY CHANGES REQUIRED BY OTHER TRADES DUE TO SUBSTITUTION OF ALTERNATE EQUIPMENT SHALL BE INCLUDED IN THE ALTERNATE PROPOSAL. 26.ALTERNATE PROPOSALS WILL BE ACCEPTED OR REJECTED BEFORE ISSUANCE OF CONTRACTS. NO CHANGES WILL BE ALLOWED AFTER THE CONTRACT IS SIGNED. ANY UNAUTHORIZED CHANGES TO THE DESIGN AND LAYOUT MAY BE REQUIRED TO BE REMOVED AT CONTRACTOR'S EXPENSE IF DEEMED NECESSARY BY THE ARCHITECT, ENGINEER OR OWNER'S REPRESENTATIVE. 27.VERIFY LOCAL CONDITIONS AT SITE. 28.COMPLY WITH ALL APPLICABLE CODES. 29.SECURE AND PAY FOR ALL REQUIRED PERMITS. 30.SEE REFLECTED CEILING PLAN FOR EXACT LOCATION OF CEILING GRID, LIGHT FIXTURES, ETC. 31.ALL INSULATION MATERIALS, INCLUDING, BUT NOT LIMITED TOO DUCT INSULATION AND PIPING INSULATION SHALL HAVE A FLAME SPREAD RATING OF 25 OR LESS (ON THE FLAME SPREAD TEST SCALE) AND SMOKE DEVELOPMENT OF 50 OR LESS (ON THE SMOKE TEST SCALE) OR AS DEFINED BY NFPA 255 STANDARD METHOD OF TESTING OF SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS, LOCAL CODES AND LOCAL AUTHORITIES HAVING JURISDICTION. 32.DIELECTRIC UNIONS SHALL BE USED TO CONNECT DISSIMILAR METALS OR METAL PIPING SHALL HAVE METAL CONNECTIONS ON EACH END THREADED TO MATCH THE ADJACENT PIPING. METAL COMPONENTS SHALL BE SEPARATED BY A NYLON INSULATOR TO PREVENT CURRENT FLOW BETWEEN DISSIMILAR METALS. UNIONS SHALL BE SUITABLE FOR THE SYSTEM OPERATING PRESSURES AND TEMPERATURE WELD TYPE: ASTM A -234. VACUUM BREAKER » HW UNION (TYP.) WATER HEATER 2" WIDE 20 GA SHEET METAL BAND, SECURE TO WALL FOR SEISMIC BRACING WHERE REQUIRED BY CODE GALV. DRIP PAN 1" DRAIN TO FLOOR DRAIN WITH APPROVED AIR GAP WATER HEATER PIPING DETAIL NOT TO SCALE :p -- � �y REVIEWED FOR CODE COMPLIANCE APPROVED DEC 2 2 2009 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWLA DEC- 14 2009 PERMIT CENTER DATE: fl/5 /09 JOB NO: OS-066 DRAWN: STAFF CHECKED: DP 'B' -ISSUE DATE 'C -ISSUE DATE WA- M cc oo � Wco 1-1-1 (N 0<f2 O N E V %TBD REVISIONS W -i8 1 �, LANDLORD WORK UNDER LANDLORD PERMIT PATE 12/6/09 SHEET TITLE FLOOR PLAN PLUMBING WORK SCALE 114' -1' -0' SHEET NUMBER P1.0