HomeMy WebLinkAboutPermit 5617 - Boeing - ReroofBUILDIt!i PERMIT
(POST WITH INSPECTION CARD AND PLANS
IN A CONSPICUOUS LOCATION)
CITY OF TUKWILA -
Department of Community Development - Building Division
6200 Southcenter Boulevard, Tukwila WA 98188
(206) 433 -1849
BUILDING
PERMIT NO.
DATE ISSUED:
675-/Fr
505 BAKER BLVD
FEES
DESCRIPTION
AMOUNT
RCPT #
DATE
BUILDING PERMIT FEE
317.00
980W
5 -25 -89
PLAN CHECK FEE
CUSTOM ROOFING, INC.
PHONE 762 -0170
BUILDING SURCHARGE
3.50
9809
5- 25-89
ENERGY SURCHARGE
CUSTOR*291M9
SQUARE
FEET
EXP. DATE 9/30/89
OTHER:
N/A
SQUARE
FEET
OCC.
LOAD
TOTAL -
320.50
SQUARE
FEET
OCC.
LOAD
uI
v
89 -111
34,500.00
PROJECT NAME/TENANT
BOEING FACILITY
ASSESSOR ACCOUNT #022310 -0101
TYPE OF ❑ New Building Addition Tenant Improvement (commercial) Li Demolition (building) CT-Grading/Fill
WORK: ❑ Rack Storage XJ(Rerool ❑ Remodel (residential) ❑ Other:
DESCRIBE WORK TO BE DONE: REMOVE LOOSE GRAVEL FROM EXISTING ROOF AND INSTALL NEW
BUILT UP ROOF AND RELATED SHEET METAL.
PROPERTY OWNER
WILLIAM E. BOEING, JR.
W —
PHONE (206) 624 -4494
ADDRESS
1325 FOURTH AVENUE BLDG
SUITE 1940 SEATTLE, WA
ZIP 98101 -2510
CONTRACTOR
CUSTOM ROOFING, INC.
PHONE 762 -0170
ADDRESS
8001 FIFTH AVENUE SOUTH
SEATTLE, WA
ZIP 98108
WA. ST. CONTRACTOR'S LICENSE #
CUSTOR*291M9
SQUARE
FEET
EXP. DATE 9/30/89
ARCHITECT
N/A
SQUARE
FEET
OCC.
LOAD
PHONE
ADDRESS
SQUARE
FEET
OCC.
LOAD
TOTAL
SQUARE FEET
ZIP
TYPE OF CONSTRUCTION: CM UBC EDITION (yeai)985
SETBACKS: N — S — E —
W —
CODE COMP( DANCE
UTILITY PERMITS REQUIRED? ❑Yes �No
(through
public warm)
ZONING: CM BAR /LAND USE CONDITIONS❑YesX ®No
USE -}
CONDITIONS (other than those noted on or attached to permit/plans):
FLOOR 4
SQUARE
FEET
OCC.
LOAD
SQUARE
FEET
' OCC.
LOAD
SQUARE
FEET
OCC.
LOAD
SQUARE
FEET
OCC.
LOAD
SQUARE
FEET
OCC.
LOAD
TOTAL
SQUARE FEET
TOTAL
OCC. LOAD
TOTAL
TYPE OF CONSTRUCTION: CM UBC EDITION (yeai)985
SETBACKS: N — S — E —
W —
FIRE PROTECTION: ❑Sprinklers ❑ Detectors ❑ N/A
UTILITY PERMITS REQUIRED? ❑Yes �No
(through
public warm)
ZONING: CM BAR /LAND USE CONDITIONS❑YesX ®No
CONDITIONS (other than those noted on or attached to permit/plans):
APPROVED FOR
ISSUANCE BY:
11149
JAW
I hereby cert. y t at I have read and e t ve ed this permit and know the same to be true and correct. All provisions
of law and ordinances governing this • will be complied with, whether specified herein or not. The granting of
this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws
regulating construction or the performance or work. I am authorized to sign for and obtain this building permit.
BUILDING
OFFICIAL
DATE:
SIGNATURE: f
DATE: G -
PRINT NAME: , L� f �i�, G.? COMPANY: S�px. �' t �� -�� ��of�`�
This permit shall become null and void if the work is not commenced within 180 days from the date of
issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection.
DATE ISSUED:
CERTIFICATE OF
OCCUPANCY NO.
t UILVIN.` i PERMIT
(POST WITH INSPEC ION CARD AND PLANS
IN A CONSPICUOUS LOCATION)
CITY OF TUKWILA
Department of Community Development - Building Division
6200 Southcenter Boulevard, Tukwila WA 98188
(206) 433 -1849
BUILDING
PERMIT NO.
DATE ISSUED:
6
y
505 BAKER BLVD
FEES
DESCRIPTION
AMOUNT
RCPT #
DATE
BUILDING PERMIT FEE
317.00
9809
5 -25 -89
PLAN CHECK FEE
CUSTOM ROOFING, INC.
SQUARE
FEET
PHONE 762 -0170
BUILDING SURCHARGE
3.50
9809
5 -25 -89
ENERGY SURCHARGE
/
OCC.
LOAD
EXP. DATE 9/30/89
ARCHITECT
OTHER:
SQUARE
FEET
PHONE
ADDRESS
TOTAL -
320.50
ZIP
uI
v
89 -111
34,500.00
PROJECTNAMERENANT BOEING FACILITY ASSESSOR ACCOUNT 22310 -0101
TYPE OF D New Building Addition Tenant Improvement (commercial) U Demolition (building) U Grading/Fill
WORK: 0 Rack Storage DReroof 0 Remodel (residential) 0 Other:
DESCRIBE WORK TO BE DONE: REMOVE LOOSE GRAVEL FROM EXISTING ROOF AND INSTALL NEW
BUILT UP ROOF AND RELATED SHEET METAL.
PROPERTY OWNER
WILLIAM E. BOEING, JR.
PROTECTION:
Sprinklers Detectors O N/A
PHONE (206) 624 -4494
ADDRESS
1325 FOURTH AVENUE BLDG SUITE 1940
SEATTLE, WA
ZIP 98101 -2510
CONTRACTOR
CUSTOM ROOFING, INC.
SQUARE
FEET
PHONE 762 -0170
ADDRESS
8001 FIFTH AVENUE SOUTH
SEATTLE, WA
ZIP 98108
WA. ST. CONTRACTOR'S LICENSE # CUSTOR*291M9
/
OCC.
LOAD
EXP. DATE 9/30/89
ARCHITECT
N/A
SQUARE
FEET
PHONE
ADDRESS
ZIP
TYPE OF CONSTRUCTION: CM UBC EDITION (yeapig85
SETBACKS: N - S - E -
PROTECTION:
Sprinklers Detectors O N/A
CODE COMET IAr10E
ZONING: CM BAR /LAND USE CONDITIONSEyesX ®No
PRINT NAME: f. (! 1 ,� ...�_« ,
CONDITIONS (other than those noted on or attached to permit/plans):
USE -
/
OCC.
LOAD
SQUARE
FEET
/
OCC
LOAD
SQUARE
FEET
/'
OCC.
LOAD
SQUARE
FEET
OCC.
LOAD
90UARE
FEET
/
OCC.
LOAD
TOTAL
SQUARE FEET
TOTAL
OCC. LOAD
nom 1
SQUARE
FEET
,
TOTAL
TYPE OF CONSTRUCTION: CM UBC EDITION (yeapig85
SETBACKS: N - S - E -
PROTECTION:
Sprinklers Detectors O N/A
AO-ugh
UTILITY PERMITS REQUIRED? (through
O Yes 12 N o Public works)
ZONING: CM BAR /LAND USE CONDITIONSEyesX ®No
PRINT NAME: f. (! 1 ,� ...�_« ,
CONDITIONS (other than those noted on or attached to permit/plans):
APPR(\'FO) FOR 1 BUILDING
ISSUANCE BY: A �, OFFICIAL
DATE: ,{ I
6 ..7c) •
I hereby cert' y t at I have read and e il'rl ed this permit and know the same to be true and correct. All provisions
of law and ordinances governing this • will be complied with, whether specified herein or not. The granting of
this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws
regulating construction or the performance or work. I am authorized to sign for and obtain this building permit.
<—.,`,
SIGNATURE: 27 L' / <,
i
DATE: (-S "" 65 7
PRINT NAME: f. (! 1 ,� ...�_« ,
This permit shall become null and void if the work is not commenced within 180 days from the date oI
issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection.
CERTIFICATE OF
OCCUPANCY NO.
DATE ISSUED:
�.id" :•x3:�tFi.�:a." +F::.....�.. <'rkY'u'Y,nn'.7�ax- ...:
CITY OF TUKWILA
Building Division
6200 Southcenter Boulevard
Tukwila, Washington 98188
(206) 433 -1849
• 6:1L0D
pe of Inspection
te Address s;-d - ,63 a -7 e-et)'e?(
questor
ecial Instructionsir%(�
INSPECT '`N RECORD �.
PERMIT # -6 ( 7
Date `7 - 7-H- 9'3°
Date Wanted %'(.dk /Ct,_, 7-/o-,51 a.m. p.m•
• Project 06
Phone # ‘ - 0 / 7 G
spection Results /Comments:
&iSlom ao
7
901.C.
8001 5TH AVENUE SOUTH SEATTLE, WASH. 98108
PHONE 762-0170
TO: City of Tukwila
6200 Southcenter Blvd.
Tukwila, Washington 98188
SUBJ:. ROOFING
PROJECT: Boeing Facility
GENTLEMEN:
505 Baker Blvd.
DATE:
6/30/89
Tukwila Washin•ton
Custom Roofing has installed a new:built. up. roofing membrane .
in compliance with the following specifications.
OWENS- CORNING SPECIFICATION # 31-IC
INSULATION 314" Fiberglass
Per Owens -Corns g specications t1 is roof ,has a Class
A rating over X7 if4' Fiberglass insulation
Please see copy of specification attached.
Si er _..,y,
Gus om Roofing, Inc.
nwi NS ( () "NINI,
FIBERGLAS
Insula VCap Sheet
33- C / 31-IC
PERMA PLY -R
PERMA PLY -IV
33 -IC All Areas
31 -IC All Areas
Il •3I
1, eauLmun
2" sidelop
Parma Cap
Application of Insulation
Apply roof insulation in accordance with specification requirements.
Insulation joints should be staggered in one direction.
For multiple• layer applications, joints of each layer should be offset a
minimum of 6 inches from all joints of the preceding layer.
Application of Plies
Embed three plies of PERMA PLY in shingle fashion (starter sheets
required), lapping 24-2/3 inches into uniform moppings of hot asphalt,
using a nominal 25 lb /100 ft2 {ter ply. Plies may be left exposed up to
six months without surfacing.
Application of Mineral Surface
Embed 12 -ft. lengths of PERMA CAP (18 -ft, in Area III) with 2 inch sidb
and end laps into a uniform solid mopping of hot steep asphalt, using a
nominal 25 lb/100 ft2. PERMA CAP end laps should be staggered 3 ft.
Interply/
Surfacing/
Slope
Nominal Installed
lb/100 ft2
(Below weights exclude roof
insulation and are provided for
system design consideration)
33 -IC
31 -IC
202
202
Application of Insulation
Apply roof insulation in accordance with specification requirements.
Insulation joints should be staggered in one direction.
For multiple• layer applications, joints of each layer should be offset a
minimum of 6 inches from all joints of the preceding layer.
Application of Plies
Embed three plies of PERMA PLY in shingle fashion (starter sheets
required), lapping 24-2/3 inches into uniform moppings of hot asphalt,
using a nominal 25 lb /100 ft2 {ter ply. Plies may be left exposed up to
six months without surfacing.
Application of Mineral Surface
Embed 12 -ft. lengths of PERMA CAP (18 -ft, in Area III) with 2 inch sidb
and end laps into a uniform solid mopping of hot steep asphalt, using a
nominal 25 lb/100 ft2. PERMA CAP end laps should be staggered 3 ft.
Interply/
Surfacing/
Slope
Bitumen
Type
Materials
per 100 ft2
Interply
Felts
3 plies
Bitumen
0 -1/2"
II, III
75 Ibs
'/2 -3"
III
75 Ibs
3 -6"
IV
60 Ibs
Surfacing
Asphalt
0 -3"
III
25 Ibs
3 -6"
IV
20 Ibs
PERMA CAP
78 Ibs
General
Note
All general instructions contained in the General Requirements
section shall be considered part of this specification.
Drainage
Roof decks must be graded to drain all water freely. Drains shall be
sufficient in number and size to assure rapid elimination of water from
the roof surface.
Nailing
Treated wood nailors aro required on inclines exceeding 2 inches per
foot to help secure insulation and roof membranes to non - nailable
decks or to decks with insulation. Nailers should be the same thickness
as the insulation and should be installed perpendicular to the slope on
8 foot face -to -face for slopes up 10 3 inches per foot and 4 foot face-to-
face for slopes greater than 3 inches per foot. Felts are to run parallel
to the Incline and must be secured at each nailer, 12" in from the back
edge of the felt. Each nail must be covered by succeeding plies High
temperature areas may require nailing on lower slopes.
1110' ,, 1.1' ,, ,•,. I141' I ,,, . I ,,, i. „r 2•
Ply Edpe io
Ply Edgo
-�• -- PEIIMA PLY
Plops
„'�+ -- ." -'^�i �""-.- -i.-.� -�� �,_- '��•- •- -._..� - '��.-- •'�-- 'L.._,,, Back al Ply
to Nail
Flashings
See Flashing Section.
33
25
1� r
UL' Specification Index ( cont'd)
Specifications Slope Insulation,
Class Surfnce Parma PI•IV Maximum Deck Type Min. Thickness Max. Thickness
A Gravel 41.IG 3" NC;C;PL 3/4" FG, P, WINC Deck Only) Unlimited
31 TG 3" NC;C;PL 3" FG, P WINC Duck Only) Unlimited
31 Ili 3" NC;C;PL 3' FG, P WINC Derck Only Unlimited
21 -1(i 3" NC;C;PL 3/4" FO. P WINC Dock Only) Unlimited
41 111 :l" N(:,C,PI 1 3" 0 4"
31I(i 3" NC,C,PL 13 "0 4"
41 Nli 3" NC.C;1'I N'A N A
31•N(i 3" NC,C,PL bb N. A
41•X(.1 3" NC.C;PL N/A N. A
31 XG 3" NC:C;PL N/A N A
Wheal Cep 41 IC 2" NC,C,I'I ba" FO; 1" P, W IMe. %" Slope) Unlimited
'/" NC,C,PL 'A" FG, P, W 4"
31 1C 2" NC,C.PL , 3/4" FO, 1" P IMnx Vr" Slope) Unlimited
NC;C,PL i4" r(i. P, W 4"
31 IC 2" ' NC;C;PL Y." FG, 1" P IMnx '/i" Slope) Unlnnnod
y4:— ...............�,....NC:C 2L....,. '4" Z.,XY. ,.»......,..,,.... 4„
21•TC 2" NC;C;PL V." FG rnt`tea
41•FC 2" NC 13•'0 4"
Vi' NC;C,PL. 1 3" 0 4"
31 •I C 2" NC 1 3" 0 4"
NC;C;PL ' 1 3" 0 4„
41•NC 2" NC MA N,'A
'N" C;PL N/A N/A
31.NC 2" NC N/A IV
' /r" C,PL N•A N/A
41•XC 2" NC N.A N • A
1/4" . C,PL N/A N•A
31XC 2" NC N/A N/A
'h" C;PL N/A N/A
Emulsion 41 .FS 'h" NC 1.3" 0 4"
41•IS 3" NC 3" FG, P 1"
1" NC 3/4" FG, P. W 4"
31.15 3" NC °/." FG, P 1"
%" NC 3h " FG, P,W 4"
31 -TS 3" NC 3" FG 4"
41•NS 3" NC N/A N/A
41•XS 3" C. • N/A N/A
Alumimnn;md 31 15 2" NC 3/4" FG, P 4"
Acrylic 41 ES /r" NC 1 3" 0 4"
41 -IS 2" NC 3/4" FG, P 1"
' /a" NC 3/1' FG, P. W 4"
31.15 2" NC 3/4" FG P 1"
' /r" - NC %" FG, P, W 4"
. Unsurtaced
41•IS 3" NC o /. " FG; ' "P" 1"
31•IS 3„ NC 3/4" FG; 3/4" P 1"
41•NS 3" NC 1 ' N/A N/A
' 41•XS 3" NC N/A N/A
Mmornl Cnp
41.IC 3 NC,C • .. 3/4" r G • Unlimited
2" PL • . 3' FG tlntinulird
:I I IC 3" NC,C .' Y�" I'G • llnlumltrti . •
2" PL . 3/4" FG . Unlimited .
' 21 •TC 3" NC;C 'A" FG • Unlineted
7." PL W FG 'Unhinged '
41 "PC , 3" . . NC .1 3" 0 • • 4,, .
31•FC d" NC 1.3".0
31 "NC 3" . NC,C • • N A N. .A '
1' " PL N.'A N/A
' 31•XC 3" NC,C N/A N.•A
Acrylic • 41 NS h" • NC;C;PL . . N/A N/A
. Aluminum 41 .IS . 3" NC 3" FG; %" P 1"
31 .15 3" NC 14 " FO: s "P
41 -NS V/' NC,C;PL N/A N/A
C Minimal Cap
41•IC 12" NC;C;PL. 3/4" FG Unlimited
31.1C, 127 NC;C;PL 3/4" FG Unlimited
21•TC 12" NC,C;PL %" FG Unlimited
41 -1C 12" NC;C;PL 1.3" 0 4"
31•FC 12" NC;C,PL 1.3" 0 4" •
41•NC 12" NC,C;PL N/A N/A
31•NC 12 ", NC;C,PL N/A N'A'
41 •XC 12" NC;C;PL N/A N/A
31 -XC . 12" - .NC:C;PL N/A N/A
Emulsion
4115 3" . NC;C,PL 3/." FG Unlimited
31 .IS • 3" , NC;C;PL '4" PG Unbnetutl
31•TS 3" NC;C,PL 3/4" FG Unlimited
41.NS 3" NC;C,PL N/A • N/A
41-XS 3" NC;C;PL • N'A N'A
LEGEND .
Duck
NC Non•Cumbusublu,
C Combustible •
PL Plywu0w111/4" Min I
N' A Nei Appltcagle
Roof Insulation
FG .Iiborulaa
D OCF(mn.'
P Petiole
W Wtxxl Egan
• Footnotes •
1 U.L. listinus must be rulurred lo obtain specific modems, uses, .
thicknesses, slopes and acceptable applicapnn methods
2 Par vapor retarder approvals, uses and slopes mler to individual
lJ 1. htainus. ' •
CITY OF TUKWI
APPROV
Mkt
B ILD
1Tt -P r+4
cos-
1• aauwwa
RECEIVED
CITY OF l'UIt: NILA
•
BUILDING Deed .
THE FOLLOWING COMMENTS APPLY TO AND BECOME PART OF THE APPROVED PLANS UNDER
TUKWILA BUILDING PERMIT NUMBER
1. No changes will be made to plans unless approved by Architect and
Tukwila Building Department.
2. All permits to be posted at job site prior to start of any construc-
tion.
3. Fire Retardant Roof Covering is required Per Section 3202(b) WBC.
4. Statement from roofing contractor verifying fire retardancy of
roof will be required prior to final (see attached letter).
5: The issuance or granting of a permit or approval of plans, specifica-
tions and computations shall not be construed to be a permit for, or an
approval of, any violation of the provisions of this code or of any
other ordinance of this jurisdiction. No permit presuming to give
authority to violate or cancel the provisions of this Code shall be
invalid. U.B.C. Sec. 303(c).
BUILDING PERMIT APPLICATION TRACKING
PLAN CHECK
NUMBER
PROJECT NAME
SITE ADD ESS
D�,lak -4
SUITE NO.
INSTRUCTIONS TO STAFF
• Contacts with applicants or requests for information should be summarized in writing by staff so that
any time the status of the project may be ascertained.
• Plan corrections shall be completed and approved prior to sending on to the next department.
• Any conditions or requirements for the permit shall be noted on the plans or summarized concisely
in the form of a formal letter or memo, which will be attached to the permit.
• Please fill out your section of the tracking chart completely. Where information requested is not
applicable, so note by using "N /A ".
BUILDING SQUARE FOOTAGE/OCCUPANCY INFORMATION
(to be filled out by Plan Checker)
SQUARE
FEET
OCC.
LOAD
SQUARE
FEET
OCC.
LOAD
SQUARE
FEET
OCC.
LOAD
SQUARE
FEET
OCC.
LOAD
SQUARE
FEET
OCC.
LOAD
TOTAL
SQUARE FEET
TOTAL
OCC. LOAD
TOTAL
DEPARTMENTAL REVIEW
"X" In box Indicates which departments need to review the project.
DEPARTMENT
ATE. I
DATE
PROVE
UIREME
MTS: / CCMMEK
4UILDING -
initial review
5-25-0
s -z5- C/
(ROUTED)
CONSULTANT: Date Sent -
Date Approved -
O FIRE
INIT:
FIRE PROTECTION: (] Sprinklers (l Detectors /A
FIRE DEPT. LETTER DATED: INSPECTOR:
O PLANNING
INIT:
ZONING: C —yyl IBAR/I.AND USE CONDITIONS? (jYes 60/No
REFERENCE FILE NOS.:
MINIMUM SETBACKS: N- S- E- W-
O PUBLIC
WORKS
UTILITY PERMITS REQUIRED?
INIT:
PUBLIC WORKS LETTER DATED:
Yes (ZNo
O OTHER
BUILDING -
final review
REVIEW COMPLETED
INIT:
P OF CONSTR 10 :
UBC DITION (year):
INIT:
PERMIT NO.
CONTACTED
CA6,210.,— 120-4---1
DATE READY
5-30
�5
DATE NOTIFIED
6 -- ( -- vi
BY:
(init.)
(�
PERMIT EXPIRES
2nd NOTIFICATION
BY:
(Init.)
y
1
AMOUNT OWING
3RD NOTIFICATION
BY:
(init.)
05/0W19
BUILDIk3 PERMIT
APPLICATION
CITY OF TUKWILA
Department of Community Development - Building Division
6200 Southcenter Boulevard, Tukwila WA 98188
(206) 433 -1849
APF'LICA TION Il1UST BL
FILLED OUT COMPLETELY
FEES (for staff use only)
SITE ADDRESS SUITE #
505 Baker Blvd.
VALUE OF CONSTRUCTION - $
34,500.00
PROJECT NAME/TENANT
Boeing Facility
ASSESSOR ACCOUNT # 022 - 310 -0101
( LEGAL DESCRIPTION ATTACHED )
BUILDING PERMIT FEE
317.00
BUILDING USE (office, warehouse, etc.)
Office Facility
NATURE OF BUSINESS:
PLAN CHECK FEE
SQUARE FOOTAGE - Building: • i 5,000 S.F. Tenant Space: SAME Area of Construction: SAME
WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE
BUILDING? ® No 0 Yes IF YES, EXPLAIN:
BUILDING SURCHARGE
PHONE (206) 624 -4494
ADDRESS 1325 Fourth Ave. Bldg., Suite 1940, ;3eattle, WA
ZIP 98101 -2.510
ENERGY SURCHARGE
3.50
ADDRESS 8001 Fifth Avenue South, Seattle, WA
ZIP 98108
OTHER::;;
EXP. DATE 9/30/89
ARCHITECT N/A
PHONE
TOTAL
320.50
SITE ADDRESS SUITE #
505 Baker Blvd.
VALUE OF CONSTRUCTION - $
34,500.00
PROJECT NAME/TENANT
Boeing Facility
ASSESSOR ACCOUNT # 022 - 310 -0101
( LEGAL DESCRIPTION ATTACHED )
TYPE OF UNew Building U Addition L) Tenant Improvement (commercial) U Demolition (building)
WORK: O Rack Storage ® Reroof O Remodel (residential) 0 Other.
DESCRIBE WORK TO BE DONE: Remove loose gravel from existing roof and install new built up
roof and related sheet metal.
BUILDING USE (office, warehouse, etc.)
Office Facility
NATURE OF BUSINESS:
WILL THERE BE A CHANGE IN USE? fix) No U Yes IF YES, EXPLAIN:
Apprx.
SQUARE FOOTAGE - Building: • i 5,000 S.F. Tenant Space: SAME Area of Construction: SAME
WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE
BUILDING? ® No 0 Yes IF YES, EXPLAIN:
PROPERTY OWNER William E. Boeing, Jr.
PHONE (206) 624 -4494
ADDRESS 1325 Fourth Ave. Bldg., Suite 1940, ;3eattle, WA
ZIP 98101 -2.510
CONTRACTOR Custom Roofing, Inc.
PHONE (206) 762 -0170
ADDRESS 8001 Fifth Avenue South, Seattle, WA
ZIP 98108
WA. ST. CONTRACTOR'S LICENSE # CUSTOR*291M9
EXP. DATE 9/30/89
ARCHITECT N/A
PHONE
ADDRESS
ZIP
1 HEREBY CERTIFY:::THAT:I HAV READ ANI EXAMINED THIS APPI,ICAT,ION A
RUE .AND .CORRECT, AND;1 AM: AUTHORIZED TO :APPLY FOR THIS PERMIT
BUILDING OWNER
OR
AUTHORIZED
AGENT
SIGNATURE
PRINT NAME
F.L. Larson
KNOW THESAME TO B
DATE
PHONE (206) 762 -0170
ADDRESS
8001 Fifth Ave. So.
CITY /ZIP Seattle 98108
CONTACT PERSON
Ed Larson
PHONE SAME AS ABOVE
APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill
out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts
are available at the Building counter which provide more detailed information on application and plan submittal
requirements. Application and plans must be complete in order to be accepted for plan review.
VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of
Community Development prior to application submittal. Contact the Permit Coordinator at 433 -1851 prior to
submitting application. In all cases, a valuation amount should be entered by me applicant. This figure will be
reviewed and is subject to possible revision by the Building Division to comply with current fee schedules.
BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or
contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent
to submit this permit application and obtain the permit will be required as part of this submittal.
EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of
application shall expire by limitations. The building official may extend the time for action by the applicant for a
period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform
p it ,09de. (current edition). No application shall be extended more than once.
CITY OF '; t , v,?If..Xou have any questions about our process or plan submittal requirements, please
contact the Department of Community Development Building Division at 433 -1849.
DATE APPLICATION ACCEPTED
DATE APPLICATION EXPIRES
03/30/89'
SlitIMITTAL CHECKLIST
COMMERCIAL
. . .... . .. . „....
NEIIICONNAERCIAL EINILD,141313/ADDITIOP49:
[I] Completed building permit applicethiii:(Onefor. each structuro)
Assessor A000unt Number • :
•
. . . .
„ , , „ „ „ , ...„.............. „.,...... .. .
• . • .." ." "... • ••::
....E.:: ::
Two MIS :the foUowin 1
..
Spe!cifications.
...,....... .
" " •• :•: :: • „
E] Structural celcUlatione stamped by a yv!oninfoOn:!s.!el!opniie,cf.
::: • •„......
„....•
soma report stamped by a WashingtOn•StateliCensitdengineet::::.:::::::::::::
„ .
•
Topographical
Energy CalculatiOns stamped by a Washington State licensed:: E••••
engineer or !architect:
Sin:tura! drawngs
• kiechanical drawngB
Elevations
•••••••••••-•:::: -••••••• • • •• • • .•••••••••••••••:: ••:: •
:::••••••••••••••••••••••••••......•:•-• :•-•••••....••••• ....
••. • • • .
COtripletetlutrlity:PermitappilCatiOnlorifOr entire:,
:".•:•••••••••• •:: ••••• " . . . • . • .
Sii(8)....setsef.c14i1
drawngs
.. .. • .
NOTE Sae utthly permlt appIkaon �id checkhat tOr."'
. •••••-••""•••••••••
RA il+PRAGE •
:•••
ri Completed bing permit Ci(
aPPlica!ispn
n'}34(2) etl!°:1•.::..f,a1; showing ra. cks las!!
Exit sione showing mote plan 6/04
and .1h$"543 s
111!;nitre
Tenant spa 6 al racks "°" State
dimensions pc:: •
by)1,1 mons and
' exit calculations
stamped ral(racii
RESIDENTIAL
Inclu on iations and
• .: . • ••• • • . • ••••• . •.:
• NEW filtIQL,E•FAIMLY D1VEl.t.INCIII/ADDIT10,10 •••:.:.::•••••':•::•• • ••••••• • ••••:•:.'•-••••
. .. ••••••••
COPAMERCIALTENANT111P.ROYEMENT'S.::::::::
r Completed 001009pern.••••• for . structure or
tenant)
Auessor Account Number
.• • •
:Eingandpropo
proposed
. .
80 derTIO, „
„ .
. . . •
Two(2) sets of
tenant footage
.. (common *CI 1!"ere
wall) squ.
c'v7 belled.
adjacent • •:eions or of
DO... tenant space
01 each room
• r ." . • . •
�fflS. • • be
FitrP.:::.••••,•::-:-„ •
• tsPOP"toss. • 11;
•
Tenan egress wa
doorS... • existing • Exit:
66. A•tr14;1. • Washington .. is to m, ••••
•• •
. ,
...• •
''• 10, required be do
Str4ctu to
. .
C°11. .. . . • ty
•:::•••••• . w rate
.."••
en
NOTE:11 ansfidu plans
appllcafion
" -- • ' -...: ' .114 permit aPPllhat19ri•E‘!..:*„ :E•oi6i':%:;--...,..:'''''':::..i."..:.:
• RERO9F........: .•::: : .• .•:„. -...; ... i :.:.•:•'::'•'•••'•.::•••• .• : • . •.:
JT] :......,....,.......:
::.Completed bu ng I no' for each structure)
:MeeSsorAccoUnt Number ' # 022 :310.
... ,......... .... .,:-. .., : ...:::::. ..- . ..,, .: . . . ::: ....... ....:.: ..
Narrative' deicribing existing roof, materiel being removed, and .:•.•••::::::
Matedal being installed:•:Stabinit... on -;Coi4pletion•
,.:::::..-.......•: .......-.. ::::: ....: ::::... .:. :: .-:::: ::::::.- : -. , ••• - : - :-.., :•.. ::: : •:::: '..*:: : ': ...: f::::
..i.NOTE:.EA carrificatlop letter.fs required Prior. to final inipactioti and sign-. ...
....'°11°.f the,. .: .Per., :sill, . .t:"..:.: .. .'...;:....:,:::; :.. :-.-.!...::.:/;'.......: .:.' .'•;.*. :• .... .. . : ... :•:•.''' .::' ...:•:.: .::::. :.;:; . :I..; ..: '.: •••;•: ........ I.::: ..: ..: ..::!:.' ... ...
Completed building permit application (one for each structure) :: •
COMpletect building perrnit'Ei pplisCatori (one for:eachstrUctUre)::
. . • . . „: . " ""
Legal. deicriptiOn : • :.::::.: • ::
, • ...
El Assessor Number::: ••• : .•;.• .
flAssessor Account Number .
• • Two (2) sets of Workingdr*Ingsi which . ' • : • •
1----1.'"'''')4!..."':.'-''.:."g,:-.,..........-:.drawings. ,............!...,..:.::::..1.:1,::::„:,,,,.::::::...,,,,,,,„.„,„...... ...,.. .,..,.. . ','.. • • •-• Floor plan10v..:a00:::•••:.
• . - .. ..
:••••••.::. Foundation plan ...•:::::•••••....• •, . ' --„::-.-41••••ttit)::::::feq Ina.::::.,::.
........:,.Roof.Plan••• '':.:••••:••••••:::::::••:••-•,.-•...::::::::::::::":::::::::•••::::•.::::::::::::::;:::••::•::::••••••:''
• .•••-•••
• StaildIng.olavatiortslall■fiews),::::::::::::::.::::::::::::::::•::::::•:::::
:.• • • . • • • • - • • • :vtft . ....•.......:••••.....::.:::,..:::::::;:1;:''''''''''''...:::'::::•••••••:::::: '''..:'..:'........'...::,....:.::,..:.'',..:..:''.•',::'.'...':'::.,..•':!:.'.F:c.o):joiId i.rlf Foundation
:••••'Pl..•::•••a:4,.....: 1,.i:.'''..:.•4i:::''•••:.:•::.::.';;1;...1....1;si'......;:'....:..:'::::;..:.'....;:,';:;..;..':•••'':::.::......::...:...•:.:.:....::-....:,...•::..:':,:::::::::::,::..:.:1':;:::'•.::;::•;::::.•'.•::,'''::"::........'•:,::••••.:.:••11.:'•.:!..:•:....-'.'...1.1•••:.:::::..?..••••••••!:::,':1:''......;.„....:'...f..1.
- .: .......................
•1•::::•'"••••..: •••:::•:.•:,::,.•• •:,:.".•:.Ouiklg:crosti7s .:. .. .. . .. .. .., ...
..„!;....;•,....,...• ::::•..::::::.••::!Structural framing : plans .::::„..:..„.......•,....... .........
'.•,,,•••:', :: ••• - : : • • • : •
..:...............,Botioing, cfasti.aaaa".........., .:........;•.:',.:':',.:1•.:::::::::. . •.::.:-::.:,:::',?......i.
,.......',....•,:.,-..iii.:::: ':.:;./.0/0TE;. If en}i.iii tiliy.workis:io.$v000 i*o.000.utiii6i00.,.##t...prici4tiof,.:::::::::.:..
. ... '..:.,•!
Structural !ramino:plafik.::::;::::::•...:...„.....:.:,,--..,::::,:::.......-.,..:::::::•,. • ••"- • ••••••••• "••-•••• ••• • • -.... •••••• •••••••••• • ..- •"•••
'•;•."0fid.P10f!04.0!....00::ff0#1111*.t:::::::::',::::••••::::::::::ii•:::.::.•::•:::::::::::::k,;••:P.::,'•q:.'„;•;.••::.:4::::::::•'•••:•••••":'••.;:iik:i:'::::"i:.•:•;•.;•-•,:;•::::.:;': •
E, Washington .State EitergyCociedatal-,i1:::::::::::::::1•:•':::::::••••••:••••••:'::::1'•'•
. • . . . ••••••• : ..,• .. . .. •......-.......,.........,..„.„.....4.,....::
• • ... • - .........:....: . . . : . ...„..................:.•;•::::::;•:::::::::, ••••••• •• : - : .... :: . •.:....„,::::...,„........,.,,.:......„:„.....:::.,.......,..........:............., .: . .
. ....... . .. , . ...................„....,.................:„.i..„....:„.:„..,.,,..........,....„.,..:,.:.....::,,... ........,...::::.:::•,,,......
•••.?.•FEROOFS.•••••i'•••••:•.:•:•,...;:,.:.: ::::::-......:•,...................,.„::.:.:.......:.......,...........„.....,... , ..
. • ...........".. • " " ..,.......•.".•:. . 2....,.......,.....:•."................„.„.•••;::...•••.,.:::..............:,•••.• •••.......„. „: •,.."..,:•••...•...•...,
.... ....,„ . „..... . :.:,,...:: ........: ..„ . .... . ...... .,......,.....,........... ...„ ...,........„ .. .. : ....,:.
corttpieted utility permit application •,---•:::::::::........:•:::::•-:-•••.::::,,...:•::::;•„,::.,
• Completed.bullciihciperrhit.appUCtitiOn.(Cati:1Or.tiach:structure)......:::::,:::::•:.
Six.1.(6): sets of site plans showing utilitiet•"': •:,• ....,..::::::::il.:::,,::::::::.::::.... ' E.Assessor:'Account Number:::;•::•;.-:::::::::,:::::::::::••:•:".....„•::::.........,..:::,•:::::.:•:......:„..„,•.„:„...:....: ..............„.....,,, ..
...... • • .-. ••• •••• • ........••••••• ...••• ...• •••.• • •.." • .• .••••.".„. ,..,.. •..•••••••••.....
NOTE Sulking site plan and utility site plan may be combined See:: • Natratiaivebd3einsorilbisrleeditisting roof, matenal being removedk and
udillYP•rmit aPPlicaticli and checklist for $ r to final Ms action' and sign
peak submittal requirements.: . meter; g n
Adebinal toPoOraPhical and 6011S information may be required if unique NOTE A ceremificafich letter d prto p
she conditions.
. off of the per