Loading...
HomeMy WebLinkAboutPermit EL08-025 - WESTFIELD SOUTHCENTER MALL - LADY FOOTLOCKERLADY FOOTLOCKER 304 SOUTHCENTER MALL ELO8-025 Parcel No.: Address: Suite No: Cityillf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 304 SOUTHCENTER MALL TUKW ELECTRICAL PERMIT Permit Number: Issue Date: Permit Expires On: EL08 -025 06/04/2008 12/01/2008 Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: LADY FOOTLOCKER 304 SOUTHCENTER MALL , TUKVVILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA MARTHA MARTIN Address: 1327 POST AV, STE H , TORRANCE CA Contractor: Name: HAGGARD ELECTRICAL CONTRACTORS LLC Address: 16702 65 AV SE , SNOHOMISH WA Contractor License No: HAGGAEC960DA Phone: Phone: 310 328 -6300 X 104 Phone: 425 - 949 -4004 Expiration Date: 03/01/2010 DESCRIPTION OF WORK: ELECTRICAL FOR NEW TI Value of Electrical: $18,000.00 Fees Collected: Type of Fire Protection: National Electrical Code Edition: Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: 'RA $471.50 2005 Date: (O'")-( --61 O `--61 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this pe does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the ance of work. .y-uthorized to sign and obtain this electrical permit. Signature: t Name: o Olo "_} Date: (9 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -025 Printed: 06-04 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 304 SOUTHCENTER MALL TUKW LADY FOOTLOCKER PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL08 -025 ISSUED 01/08/2008 06/04/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Soy/ Signature: ame: Mc,�a, -J Date: 6— 9s-08 doc: Cond -Elec EL08 -025 Printed: 06 -04 -2008 JAN,04 /2008 /FRI 05:32 PM CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hrcp: /M'wv.ci.tula ilawa,us 'S:T_E'A'X( FAX No. P, 008 ELECTRICAL PEIz1VMIT APPLICATION Applications and plates must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by tax. *'"Please Print" Site Address: Tenant Name: LCI dk j cci - CSC ¥ er Property Owners Name: W€Sk iel d COY POYCA'tl OYl Mailing Address: 1 f OOY ,,* 1 . t 5 ! :� vd King Co Assessor's' fax No.: Suite Number: 1 S (0 Floor: j New Tenant: ❑ .....Yes El _No •/ ty 6..00.icreon rftiv�iiwi:} +,ti'• rndC�+;i-tpik ti`talteiasiit Name: 11- tq Martin n Mailing Address: r• I • II •� S L MailAddressMa via Meaafizip-xernn 1 ram Slab Zip Day Telephone. 3(0 .32e) .103c X-1-• 1 Oy C City State Zip Fax Number: 31 G • .1 1 Li 2- Company Name 61) Mailing Address: City Contact Person: Day Telephone: E -Mail, Address: Fax Number: Contractor Registration Number. Expiration Date- Slab Zip Valuation of Project (contractor's bid price): $ 1 401 OtlO T Z . f (I/ 600 - rGe44) Scope of Work (please provide detailed information): fQiif/DE %2w NE /?1 •91 /ercg Co/0p1//T 77) s °A J s �,1�(ST /.U�- , MIMArt 19-m014 DLo ' EG6c -�• Will eervice be altered? r Yes ❑ No G Type of use: Type of work: ❑ New 0 Addition ❑ Low Voltage ❑ Generator Property Served to : .k Puget Sound Energy ❑ Scathe City Light 1eert/4 - Slttb Adding more than 50 amps? MYes ❑ No [] Scry ce Cbenge ❑ Remodel •enant Improvement ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service 11'uppfimnoni■Formo- Appli.64. On Ian eU1- 2r'4 -Ekm 1 Ponnia Applcatlaadoc La Page 1 on JAN /04 /2008 /FRI 05:33 PM FAX No, P. 009 R)CSWENTYA% NEW RESIDENTIAL SERVICE [] ticw single funnily dwoJlings 5140.00 (including an attache! garage) ❑ Garages, pools, spas and outbuildings S75.00 ea ❑ Low voltage systems (alann, furnaces thermostat) F5S.00 ea RESIDENTIAL AL 1 ENIODltL, AND SERVICE CHANGES ❑ Service change or tiltemtion $75.00 (nn added/altered circuits) ❑ Service change with added /altered circuits 575.00 number of added circuits S10.00 ea ❑ Circuits added /altered without service. change 550.00 (up to 5 circuits) ❑ Circuits added/altered without service change .... S50.00 (G or more circuits) S7.00 oa ❑ Meter /mast repair 565.00 ❑ Low voltage systems 555.00 (alarm, furnace thermostat) hrut,TI -n,� Mt �� AND COMMERCIAL Fees are based cm the valuation of the oleetricul Contract. MISCELLANEOUS FELLS ❑ Temporary service(residtnttial) S58.0U [� Temporary service (generator) 575.00 ❑ Manufactured/mobile home service S80 00 (excluding garage or outbuilding) ▪ Carnivals $75.00 Number of concessions 510,00 ea Value of Construction — In all cases, a value of conshictioo amount should be catered by the applicant- This figure will be reviewed and is subject to possible revision by the Permit Ccnt r to comply with current too Sohodales. ILxpltrititia M Kati Review — Applications for which no permit it issued within L80 days following the dale of application shall cxptrc by limitation, The Building Official may grant ono extension of time for an additional periutf not to exceed 00 days. The extension shall be tequosted in writing end justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND QED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OR 'PERJURY BY THE LAWS OF TIE STATE OF WASHINGTON, AND [ AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING QVV ER OR ELECT ICAL C fRACTOR? A &iji7 f Signature: Print Name 7;q/11k /11. 1/4/11/1. Mailing Address; s6 2 SfC".4 ■ _/' Day Telephono: City Date: O/d 972 -7/¢ -i 20 7,, Z Sate Zi IDate Application Accepted: [ Date Application E>Lpirets: StaIT Initials: 1 M:Npptlevinut ono.- nrokati m• on Lin u`4 -2001 - L?loi.trionl Minns APldlwoon.Joe L4 Page 2 of 2 4 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -025 Address: 304 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 01/08/2008 Applicant: LADY FOOTLOCKER Issue Date: Receipt No.: R08 -00056 Initials: User ID: Payee: JEM 1165 Payment Amount: $94.30 Payment Date: 01/08/2008 11:05 AM Balance: $377.20 EXPRESS PERMITS TRANSACTION LIST: Type Method Description Amount Payment Check 10668 94.30 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 94.30 Total: $94.30 6966 02./08 9710 TOTAL 94.30 doc: Receiot -06 Printed: 01 -08 -2008 INSPECTION NO. INSPECTION RECORD Retain a copy with permit E PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Loco Type of Inspection: Address: 3AL4 tiviti Date Called: Special Instructions: Date Wanted: "7 it \-e a:m1 Requester: Phone No: 71 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 1;1 &14/41( Date: °It lk El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: $ere4�:W '.tlR'o*. I.4 .y011.-.- ..r .. ___•...a�.._��_..._�_ .a..w��rdsf amekdS .,.±sue- h INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit F,w9i -off PERMIT NO. Project: J( Lp� Type of Inspection: p 1Q1) Address: O Date Called: .---- Special Instructions: Date Wanted: 1111 a:m. m. Requester: Phone No: Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: Inspector: ■Tirl Strdakitc Date: 07f4ok El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be !Q paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Eti3V-off Project ��� Type of Inspection: 01- Address: ; q 11 Date Called: Special Instructions: Date Wanted: 07 b Cy Requester: Phone No: PS1 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: • l s • ma K.a. 5C4-L Kam e 1 t: SGwJtie -c - Inspector: l Date: Cl 14 I(11 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Y INSPECTION RECORD Retain a copy with permit PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 7 Project: +I f, T1 K Type of Inspection: T70J3 1Gd Ae Date Called: Special Instructions: //— / 2. Date Wanted: 6/6;4 p.m. Requester: Phone No: roved per applicable codes. El Corrections required prior to approval. .COMMENTS: in n -- cL_ •L /A) cw -- <; /L f5 A m �l (o Inspect` r. ` de 7401/016g Date: 6h6Ar 1-1$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 3 INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION fit. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: ,Gamy f d 4.-0 Type of Inspection: ype 7Ge)3 Address: 201/ 72161A0Z, Date Called: Special Instructions: Date Wanted: // m. Requester: (/ Phone No: rig proved per applicable codes. Corrections required prior to approval. COMMENTS: p/t) - /n/T -/Ufi POI Li Inspe i/" M/6 /I Date:/_` > /0f r7 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Rard�..k.�i®: . Q. .��aa,: •.. �.s:�r r � if244126• AIWA 6ug -oz( 1 INSPECTION NO. . , INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION t 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: �O Type of Inspection: 7C49.2 Address. 3011 � Date Called: Special Instruction Date Wanted: J� I a p.m. Requester: Phone No: Approved per applicable codes. D Corrections required prior to approval. ' COMMENTS: Vfr Inspector: I0ate/to/ v ri $60.00 REINSPECTION FEE REQU RED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTfON RECORD *CL4V_0 7-0 Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: rt Lo c� 1 Type of Inspection: 7003 Address: 14 Date Called: Special Instrucctirns: Date Wanted: 6t I( a.m Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: OIL - DEA( tA Inspector: Lill &gm, Date: i� a4 j( f ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 1Date: d...Y4w'r�l6e�•� 7�L. iyGled•f..l.a ft. -� �,s..uM �_.2�:.1.��i'= �.b� -�u 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary LTG -INT 2008 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address SOUTHCENTER MALL Date 2/22/2008 633 SOUTHCENTER PKWY For Building Department Use R IE{jyE.D� FFOR CODE rr'��CA�� M'��-1AN( IMEr' 710 - NEC TUKWILA,WA 98188 SPACE# 1560 Applicant Name: LADY FOOT LOCKER Applicant Address: 5 - Fill out this line on PRJ -SUM Applicant Phone: 6 - Fill out this line on PRJ -SUM Project Description RETAIL SALES /FITTING AREA /NOTE #10 DISPLAY U�� ❑ Pla s Indude re uirements. 144 �! New Building Addition AlterationI g ❑ ❑ Refer to WSEC Section 1513 for controls and commissioning AREA #2 Compliance Option 0 QPrescriptive • Lighting Power Allowance t +�a��4� 0 Sy ems An (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces de/ANC/MO Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2"* Area in ft2 Allowed x Area AREA #1 RETAIL SALES /FITTING AREA 1.50 1209.0 1813.5 AREA #1 RETAIL SALES /FITTING AREA /NOTE #10 DISPLAY 1.50 1209.0 1813.5 AREA #2 WAREHOUSE /STOCK RM. ,OFFICE 0.50 888.0 444.0 " From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 4071.0 Proposed Lighting Wattage Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed AREA #1 F2/2 X 2 REC. FLOU. 3 -LAMP (40W) BIAX 16 103.0 1648.0 AREA #1 RD /8" RD REC. FLOU. DNLT 1- LAMP(42W) TT 8 42.0 336.0 AREA #1 A4 -N /TRACK HEAD 1 -LAMP (35W) (44W W/ BALLAST) 3 44.0 132.0 AREA #1 TF2 /TRACK HEAD FLOU. 1- LAMP(40W) BIAX 11 40.0 440.0 AREA #1 A4 /TRACK HEAD 1 -LAMP (25W) MH(30W W /BALLAST) 32 30.0 960.0 AREA #2 F1 /4 FT. STRIP FLOU.1 -LAMP (32W) T8 17 32.0 544.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 4060.0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. INCOMPLETE aoe o& • FILE COPY N FEB 2 2 2008 PE . 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary (back) LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Prescriptive Spaces Occupancy: O Warehouses, storage areas or aircraft storage hangers OOther Qualification Checklist Lighting Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. Note: If occupancy type is 'Other and fixture Fixtures: Convention center answer is checked, the number of factures in (Section 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector the space is not limited by Code. Clearly 1521) or louvers, c) 5 -60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- indicate these spaces on plans. If not Cafeterias, fast food establishments', restaurants /bars5 tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. qualified, do LPA Calculations. 1.1 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 1.0 Retail's, retail banking, mall concourses, wholesale stores (pallet rack shelving) 3. LED lights. LE 15 -1 Unit Lighting Power Allowance (LPA Use' LPA` (W /sf) Use' LPA` (W /sf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches) 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations" 1.0 Cafeterias, fast food establishments', restaurants /bars5 1.3 Post office 1.1 Dormitory 1.0 Retail's, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia", assembly spaces" 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses ', storage areas 0.5 Hotel banquet/conference/exhibition hail''' 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified °laboratory' shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries° 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies° (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used. 8) Reserved. 9) For indoor sport toumament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three- quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling - mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. February 21, 2008 • • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Martha Martin 1327 Post Avenue, Suite H Torrance, CA 90501 RE: Letter of Incomplete Application # 1 Electrical Permit Application EL08 -025 Lady Footlocker — 304 Southcenter Mall Dear Ms. Martin, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on January 8, 2008 is determined to be incomplete. Before your application can continue the plan review process the following item from the following department needs to be addressed: Building Department: Bill Buterbaugh, at 206 973 -4758, if you have any questions concerning the following comments. 1. Provide Washington Sate Energy Code Lighting Budget calculation. Please address the comment above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that three (3) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, Brenda Holt Permit Coordinator Enclosures File: EL08 -025 P:U'ermit Center Incomplete Letters\2008\EL08 -025 Incomplete Ltr # 1.DOC wer 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 - 431 -3665 • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -025 DATE: 06 -09 -08 PROJECT NAME: LADY FOOTLOCKER SITE ADDRESS: 304 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 After Permit Issued DEPARTMENTS: RR 1/� �� Building ivislon Public Works 111 Fire Prevention Structural Planning Division n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 06-1 0-08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required n DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 07 -08 -08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -025 DATE: 02 -22 -08 PROJECT NAME: LADY FOOTLOCKER SITE ADDRESS: 304 SOUTHCENTER PY Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: BGlYding Division Public Works n Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 02 -26 -08 Complete Incomplete Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROIJTING: Please Route Structural Review Required REVIEWER'S INITIALS: nNo further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03-25-08 Approved n Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 OPERM1T COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: ELOS -025 DATE: 01 -08 -08 PROJECT NAME: LADY FOOTLOCKER SITE ADDRESS: 304 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: iffe-0(& ng 'vision Public Works Fire Prevention Structural Planning Division nPermit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete I Comments: Incomplete DUE DATE: 01-10 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: `'-�� LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initial TUES/THURS ROUTING: Please Route j 1 Structural Review Required REVIEWER'S INITIALS: n No further Review Required DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 02 -07 -08 Approved n Approved with Conditions n Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 • • City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http : / /www.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Plan CheckfPermit Number: e1- - 0a 5 Revision # 1 after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: L-A-0't' ' - C ER— Project Address: -3 Oil S,JTN CEATWIZ Contact Person: \AScay i M I .1)Kts Phone Number: So 3 ~3 5 F G g`7, Summary of Revision: A-0 D (T(v>ci C T /N STZZK/2Oz)11-A FOR GE /_itUG- ELECT mover) 34 < j ey /-.e CITY OF TUKWILA ►JUN 0 9 2008 aF1 {11n1 . Sheet Number(s): E I / 3 E X4/ "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: `- 0/ Entered in Permits Plus on() / 9/d ' lapplications\forms- applications on Iine\revision submittal Created: 8-13 -2004 • 1 City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 2 -12-2-41 Plan Check/Permit Number: L D8 - p [� Response to Incomplete Letter # / ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Project Address: 3U 4L! CSU Geri W Tckuh bt Wk 92'/ a Contact Person: /414 r kiar Phone Number: ,..d/0 -31$ • 4344 IC /64( Summary of Revision: 3 C• 4 e s 2-404 4 l.t)/4— S ea ufeQd.. RECEivro CITY OF TIiK\H/ILA 413 22 2008 Sheet Number(s): A/A "Cloud" or highlight all areas of revision including date o revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on � � -0 " \applications \forms - applications on line\revision submittal Created: 8-13 -2004 R.oiavri- NJ2-0( Look Up a Contractor, Electrician or Plumber License Detail 1110 • Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License HAGGAEC960DA Licensee Name HAGGARD ELECTRICAL CONTRS LLC Licensee Type ELECTRICAL CONTRACTOR UBI 602357747 Ind. Ins. Account Id PARTNER/MEMBER Business Type LIMITED LIABILITY COMPANY Address 1 16702 65TH AVE SE Address 2 City SNOHOMISH County SNOHOMISH State WA Zip 98296 Phone 4259494004 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 3/1/2004 Expiration Date 3/1/2010 Suspend Date Separation Date Parent Company Previous License Next License Associated License HAGGAR *964CL Electrical Administrator Information License HAGGAR *964CL Name HAGGARD, RYAN Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date HAGGARD, RYAN L PARTNER/MEMBER 03/01/2004 HAGGARD, ELIZABETH A PARTNER/MEMBER 03/01/2004 Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= HAGGAEC960DA 06/04/2008 Parcel No.: Address: Suite No: Applicant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 304 SOUTHCENTER MALL TUKW LADY FOOTLOCKER RECEIPT Permit Number: Status: Applied Date: Issue Date: EL08 -025 ISSUED 01/08/2008 06/04/2008 Receipt No.: R08 -02542 Initials: BLH User ID: ADMIN Payee: Payment Amount: $58.00 Payment Date: 07/14/2008 12:37 PM Balance: $0.00 MARKET CONTRACTORS TRANSACTION LIST: Type Method Descriptio Amount Payment Cash 58.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 58.00 Total: $58.00 4777 07/14 0711 TOTAL 58.00 rinn. RPCaint -OA Printold 07 -14 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -025 Address: 304 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 01/08/2008 Applicant: LADY FOOTLOCKER Issue Date: Receipt No.: R08 -01943 Payment Amount: $377.20 Initials: WER Payment Date: 06/04/2008 02:40 PM User ID: 1655 Balance: $0.00 Payee: HAGGARD ELECTRIC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 14514 377.20 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 377.20 Total: $377.20 3241 06/04 9711 TOTAL 377.20 doc: Receiot -06 Printed: 06-04 -2008 _ SOUND SYSTEM FOOT LOCKER INC. STORE PLANNING DEPT 112 WEST 34TH STREET NEW YORK, NY 10120 PHONE 4 FAX O COMPUTER O DATA fi- ARCHITECT: JAMES M. HAMILL, A.I.A. , 580 DECKER DRIVE, SUITE 170 , I RVI N G, TEXAS 75062 PHONE: 972 714 -0420 ®� NEW EXIT ALCOV G��pyd��� N. - 4�y�Vyydr NEW .•YOILET r r 1 , WLIKIEW'W QI I ;A U"1 L PWR • -11 A -11 Ili.- _ �� iV A -30 �� 1 J COP ' I _ �' 0 ����������� . --___— ..v____ A -1 � - ..E �. '�:�. �� 1 _ Approval of ��� 1 (U rl� •��@ ��� :� ^ �ir�iYPE 0 J • +u 4lo /1 :, 1`1A D AGEi�'S (T"t PAD / ��fl�3. . +�.�1 n A -9 _- 40 ® EXISTING -/ DISCONNE MOVE AB 12. E,� 1 + h 0 a � TOMANAGy�� \��1� �� 8 -20 -F +---- +- - - ---1 _ __� �:�1 0 PROJECT CO - ORDINATOR: a K r P A U L P A R T N E R S H I P .. TORONTO • CALGARY • VANCO UVE R 0 2660 Sherwood Heights Dr. Suite 200, Oakville, Ontario, L6J 7Y8 1- 888 - 855 -5061 fax 905 337 -1986 ( ) W F DESK 7 -l'i -e 8 ����•�F �,� _ _ A 20 T� = 1 E10 �i A -1 A -19 - V- - � of TukWDa BUILDING DIVISION �, e _ - - - -NEW 0 T 6sr��..�� ©'AV -1 ROOM FITTING AND I �� / BOAEP • L •-iic © / ____ ilisiv,*. A 15 1 1 1 L- - - - -�- -- I - - -- I - - - �CCESSORIkB �� __ '1 ■,~ \ = / NEW - J BAGKWRAP ( rw CQD , • O � /�O /j/ F Q~� 15 A �� ' I - id NEW STOREFRONT C.T. I 3.iT I _I ,,1 I ( AND CASHWRAP /c AND GLASS DOORS r _ 7-1--1 —E -11- 71- 7 YI. 7-7 77-7 —II— T—17T7I --I (TYP . II I I 11 I II I 1 1a I I� I I I I I 1 I II 1 II I I1 1 I1 I��� I I I I I I I I I TAI ,� 11 I 11 11 I 11 1 1 I ['' � ' 0 I ` / �, 1:7 / ENGINEER 1 1 11 I 11 1 11 I 11 11 18 I I I I 11 E4.0 I������������ II ��������������I III LJ ��-11 \ I REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. t�t'at NOTE: Reuisians wilt require a Cepvjew fees. and may include addrtlorlal p '0 I I� /, \ 1 / ` \ \ I 1 ` �fY►' , ►� p _ I I II II I II I I I I I I I I 1 1 i t I 11 1 I II I II I II II I 11 1 I I I I I I I I 1 11 I 11 I 11 I 11 + I CTY1) I I I I I I I I I i I I 11 \ / ` ' i _ 11 I 1 1 I I 11 1 11 I 11 I I I 11 I I I 1 _L _IL J _IL J L J L _J1 L L J I Emphasis On Excellence M. Retail Engineering, Inc. We Broole, Ohio Blvd. Westerville, Ohio 43081 TEL: 614.818.2323 FAX: 614.818.2337 1 . >_ -1 • - T - - -- -- 1 111 11 �- .• .. .- . -, �� Ili (TYP) ® (TYP) ® A -� >� *ED C� � Y� �DR` IN COD 00 co o�E� le 0_ 112 ° °' 1�� +� . %Ala • . s CPGA0rs1 -: 1 ,, r,.; .: , t'T;: ,- '64/0 AL % ¢ __,. 07 i 31 Q vpl> s LL WILL PROVIDE A COMMUNICATION GABLE TRAY LOCATED IN UTILITY CORRIDOR FOR TENANT'S USE. NO CONDUIT WILL BE PROVIDED. LL WILL PROVIDE A COMMUNICATION TERMINAL BOARD WITHIN EACH LL ELECTRICAL ROOM_ TENANT SHALL PROVIDE AND INSTALL A COMPLETE TELEPHONE SERVICE SUPPORT FACILITIES AS REQUIRED BY THE SERVING TELEPHONE COMPANY. ALL TENANT TELEPHONE EQUIPMENT SHALL BE CONTAINED WITHIN THE TENANT'S SPACE. TENANT'S TELEPHONE EQUIPMENT 15 NOT PERMITTED IN LL'S TELEPHONE EQUIPMENT ROOM. TENANT SHALL PROVIDE PLENUM RATED WIRE FROM THE TELEPHONE ROOM TO THE TENANT'S TELEPHONE EQUIPMENT WITHIN THE DEMISED PREMISES UTILIZING THE LANDLORD SUPPLIED CABLE TRAY. ANY CORRIDOR WALL PENETRATIONS WILL NEED TO BE FIRE CAULKED AS REQUIRED. LL SHALL FURNISH AND INSTALL ONE FIRE ALARM JUNCTION BoX INSIDE THE DEMISED PREMISES FOR EACH TENANT'S USE IN CONNECTING THEIR INDIVIDUAL FIRE ALARM SYSTEMS OR COMPONENTS. TENANT SHALL FURNISH AND INSTALL ALL NECESSARY INITIATION DEVICES, ANNUNCIATION DEVICES AND CONTROLS AS REQUIRED BY LOCAL AUTHORITY HAVE JURISDICTION. TENANT SHALL CONTRACT WITH LANDLORD'S DESIGNED FIRE ALARM CONTRACTOR FOR DESIGN, PROGRAMMING AND FINAL CONNECTIONS TO LANDLORD'S FIRE ALARM SYSTEM AT TENANT'S EXPENSE. TENANT SHALL USE ONLY LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR SPECIFIED EQUIPMENT TO ENSURE NOTE: IN 1- 1ANDICAFPED AREAS, THE RECEPTACLES AND TELEPHONE OUTLETS SHALL 5E MOUNTED COMPATIBILITY WITH LANDLORD'S FIRE ALARM SYSTEM. A COPY OF FIRE ALARM REVISIONS NO. DESCRIPTION DATE 1. REVISED AS PER 04/04/8 LANDLORD AND CLIENT COMMENTS 2. REVISED AS PER 06/02/8 CLIENT COMMENTS AT 2411 A_FF.± THE TOGGLE SWITCHES, THERMOSTATS AND MANUAL MOTOR STARTERS DRAWINGS SHALL BE ISSUED TO THE LOCAL FIRE MARSHAL'S OFFICE. SHALL BE MOUNTED AT 4211 AFF. 0 POWER PLAN ALL SYMBOLS DO NOT NECESSARILY APPLY SCALE: 1/4" = 1' -0" DATE: 12/17/07 FIELD VERIFY ALL CONDITIONS SYMBOL DESCRIPTION MOUNTING HGT. TO CENTERLINE UNLESS OTHERWISE NOTED SYMBOL DESCRIPTION MOUNTING HGT. TO CENTERLINE UNLESS OTHERWISE NOTED SYMBOL DESCRIPTION MOUNTING HGT. TO CENTERLINE UNLESS OTHERWISE NOTED SCALE: AS NOTED DESIGN DRAWINGS ARE SGHEMATIG. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. ubrr. q. ���1n� nl,ri..r,.. 0 WIRED JUNCTION BOX SEE DRAWINGS -- MANUAL MOTOR STARTING SWITCH W/ PILOT LIGHT 48" AFF. (TYP) F FIRE ALARM BREAK STATION 48" AFF. (TYP) GROSS AREA: 2,164 SQ. FT. 70 DUPLEX RECEPTACLE, 3 WIRE GRD. TYPE, 20,4 18" APP. (TYP) TELEPHONE OUTLET 18" AFF. (TYP) FIRE ALARM AUDIO /VISUAL SIGNAL DEVICE 00" AFF. (TYP) SALES AREA: 1,272 SQ. FT. OUJP DUPLEX RECEPTACLE, WEATHERPROOF,20A 1S" AFF. (TYP) N 2 TELEPHONE OUTLET - DUPLEX 18" AFF. (TYP) ® SMOKE DETECTOR AT FINISH CEILING PROJECT # : 0712260 GFI GROUND FAULT PROTECTED DUPLEX RECEPTACLE, 204 1S" APP. (TYP) I< DATA OUTLET - CATEGORY 5 18" AFF. (TYP) I# FIRE ALARM VISUAL SIGNAL DEVICE 80" AFF. (TYP) DRAWN BY: i?% QUADRAPLEX WALL RECEPTACLE, 20A 18" AFF. (TYP) 1:12 DATA OUTLET - DUPLEX CATEGORY 5 18" AFF. (TYP) n PANIC EXIT DOOR LOCK GF.I. W /LIGHT 4 SWITCH AS REQUIRED AS REQUIRED N 15" VGA MONITOR I 1-1 SAFETY SWITCH Ld Foot L • PUSHBUTTON STATION 48" AFF. (TYP) ® MAGNETIC MOTOR STARTER AS REQUIRED ® MINI DOME CAMERA 1 LOW VOLTAGE BUZZER TRANSFORMER AS REQUIRED A5 REQUIRED APV MONITOR -A COMBINATION STARTER/SAFETY SWITCH L I� DOOR BUZZER 54" AFF. (TYP) ® MOTOR OUTLET - 1 PHASE AS REQUIRED � 4 TOGGLE SWITCH - SINGLE, 3 -WAY 4 4 -WAY 48" ARE (TYP) ® MOTOR OUTLET - 3 PHASE AS REQUIRED PERMI ERMITNUMBER ELECTRICAL SYMBOLS n n 1. REFER TO MECHANICAL PLAN FOR LOCATION OF MECHANICAL EQUIPMENT. FIELD VERIFY EXACT LOCATIONS. 2. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL AT PANEL 'A' TYPED PANEL DIRECTORY WITH ALL CIRCUITS ACCURATELY DESCRIBED PRIOR TO STORE OPENING. 3. ALL RECEPTACLES AND SWITCH PLATES IN SALES AND NON -SALES AREAS TO MATCH WALL OR CEILING FINISH UNLESS DIRECTED OTHERWISE. TYPICAL MOUNTING TNH HEIGHT IS 18" AFF. EXCEPT AT COUNTERS OR 4. ALL CONDUITS SHALL BE CONGEALED IN WALLS AND OUTLET BOXES SHALL BE FLUSH WITH FINISHED WALL UNLESS OTHERWISE NOTED. 5. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH NATIONAL ELECTRIC CODE AND ALL LOCAL CODES AND ORDINANCES. O 20AMP, 120V_, ISOLATED GROUND /DEDICATED CIRCUIT RECEPTACLE 1 HU SIG -5362) FO GASH GISTERS. DO NOT INSTALL WITH ( BBELL R RE ANY OTHER CIRCUITS. LOCATE RECEPTACLES AT GASH/WRAP COUNTER AS DIRECTED BY OWNER/ARCHITECT. RUN 2 412 THHN AND 2 X12 ISOLATED GRD. PER CIRCUIT IN A COMMON 1" CONDUIT IN FLOOR SLAB TO WALL, UP WALL AND TO PANEL. O NOT USED. 3 NOT USED. 4 SEE DETAIL C /E1.1 FOR TELEPHONE REQUIREMENTS. ® ® 20AMF, 120v., DUPLEX RECEPTACLE AT CASH WRAP COUNTER FOR UTILITY POWER LOCATE RECEPTACLES AT CASH WRAF COUNTER AS DIRECTED BT OWNER. RUN 2 ,*12 THW AND 1 $12 GRD IN 1" CONDUIT IN FLOOR SLAB TO WALL, RUN UP WALL TO JUNCTION BOX AND CONNECT TO CIRCUIT INDICATED. REFER To CABLE BLOCK DIAGRAM ON SHEET E4.0. ® 20AMP, 120V., ISOLATED GROUND /DEDICATED CIRCUIT, RECEPTACLE (HUBBELL 0IG- 53g,2) MOUNTED AT 18" AFF. DO NOT INSTALL WITH ANY OTHER CIRCUITS RUN 2 012 THWN AND 2 412 ISOLATED GRD. IN SINGLE 3/4" CONDUIT BACK TO PANEL FOR COMPUTER TERMINAL. ® SEE DETAIL "C" ON SHEET ELI FOR TELEPHONE RISER DIAGRAM ®3/4" CONDUIT FOR CASH REGISTER WIRELESS ACCESS POINT. RUN 3/4" CONDUIT FROM CASH WRAP COUNTER TO DATA OUTLET /JUNCTION BOX AT MANAGER'S DESK. COORDINATE REQUIREMENTS WITH OWNER/ARCHITECT. REFER TO GABLE BLOCK DIAGRAM "C" ON SHEET E4.0. ® NOT USED. 10 POWER EQUIPMENT: REFER TO POWER RISER ON SHEET E3.0 FOR MORE. INFORMATION ® RECEPTACLES AND GOVERPLATES WITH AN SF DESIGNATION SHALL BE FLUSH MOUNTED IN CEILING AT STOREFRONT, PARALLEL TO STOREFRONT GLASS. CIRCUIT TO PANEL AS INDICATED. (NEC ART. 210 -62) 12 MOUNT SALES AREA DUPLEX RECEPTACLES AND COVERPLATES AT 18" AFF_ WHERE RECEPTACLES ARE LOCATED BEHIND WALL PANELS, MOUNT HORIZONTALLY AT 8" AFF.. CIRCUIT TO PANEL AS INDICATED. 13 NOT USED. 14 NOT USED. 15 sEE DETAIL F/ EI.1 FOR REAR DOOR BUZZER SYSTEM SEE DETAIL B/E 1.1 FOR PANIC EXIT DEVICE. ® 1 1/2" EMPTY CONDUIT WITH PULL STRING FROM AI-1U-1 TO THERMOSTAT. REFER To MECHANICAL DRAWINGS FOR EXACT LOCATION AND DETAILS "I-1" ON SHEET Eli. 0ELECTRICAL REFER TO VAC CONNECTION SCHEDULE FOR WIRING, CONDUIT, AND CIRCUIT Ig H REQUIREMENTS. 19 PROVIDE JUNCTION BOX, TOGGLE DISCONNECT SWITCH IN CONCEALED LOCATION AND FINAL CONNECTION FOR 120 VOLT SIGN. SIGN FURNISHED BY TENANT. COORDINATE EXACT LOCATIONS WITH TENANT'S CONSTRUCTION MANAGER. C, WIRE THROUGH TIME CLOCK REFER TO SHEET E3.0 FOR MORE INFORMATION. TIME CLOCK SHALL BE SET TO MALL'S OPERATIONG HOURS. MOUNT DUPLEX RECEPTACLES HORIZONTALLY BELOW COUNTER COORDINATE EXACT V U IJ Ap.. - ,�% _ D D 4�C �� 21 LOCATION WITH CABINET MANUFACTURER 22 RECEPTACLES AND COVERPLATES IN NON -SALES AREA SHALL BE MOUNTED AT 18 AFF. O UNLESS NOTED OTHERWISE. CIRCUIT TO PANEL AS INDICATED. 23 PROVIDE CONNECTION TO ELECTRIC WATER HEATER PER NEC. 24 DEDICATED RECEPTACLE FOR SOUND SYSTEM MOUNTED ON SHELF. VERIFY EXACT REQUIREMENTS WITH SOUND SYSTEM COMPANY "CROWS NEST" AT (425) 143 -5033. THE ELECTRICAL CONTRACTOR SHALL INCLUDE IN HIS SID THE COST FOR A COMPLETE 25 O OPERATIONAL FIRE ALARM SYSTEM. THIS SYSTEM SHALL INCLUDE, BUT NOT BE LIMITED TO, RELOCATING EXISTING DEVICES, REPLACING DAMAGED DEVICES, AND ADDING ADDITIONAL DEVICES AS REQUIRED TO MEET CODE REQUIREMENTS. A LICENSED FIRE ALARM CONTRACTOR SHALL PREPARE AND SUBMIT, TO THE LANDLORD FOR APPROVAL, A COMPLETE FIRE ALARM SYSTEM DRAWING AND MATERIALS LIST, PRIOR TO COMMENCING ANY WORK FINAL CONNECTIONS TO THE LANDLORD'S BASE SYSTEM SHALL BE BY THE LANDLORD'S FIRE ALARM CONTRACTOR AT TENANT'S EXPENSE. 28 LANDLORD'S JUNCTION BOX WITH 1" CONDUIT ,TO TIE INTO MALL'S CENTRAL FIRE ALARM SYSTEM. SEE FIRE ALARM SYSTEM . VERIFY LOCATION AND EXACT REQUIREMENTS WITH THE LANDLORD. PROVIDE AN EDWARDS SYSTEMS MODEL* 6538 -G5, OR APPOVED EQUAL, CALL FOR 27 ASSISTANCE KIT. KIT SHALL INCLUDE AN AUDIBLE WORNVSTROME, POUER TRANSFORMER, AND PULL CORD STATIONS. PULL CORD STATIONS SHALL BE MOUNTED NEAR THE TOLIET, AS INDICATED. SEE DETAIL F, SHEET E4.0, FOR MORE INFORMATION. 1 PROJECT TITLE SOUTHCENTER MALL 304 SOUTHCENTER PKWY TU KWI LA WA, 98188 > > SPACE #1550 STORE NO. 461 71 x 1" 1 I 1 1" 1 1" " ' ' / / ' ' TEL. CONDUIT 0/ DATA CONDUIT RECEIVED JUN 0 g PERMIT CEN �► ISOLATED GROUND CIRCUIT CONDUIT SHEET TITLE POWER PLAN UTILITY POWER CONDUIT EL 0 8 . 0 25, FILE COPY 1 0 ' GENERAL POWER NOTES (4 �,, POWER CODED NOTES !; TYP. CONDUIT STUB -UP @ CASHWRAP SHEET NO. J -BOX FOR DESK LIGHTING. COORDINATE EXACT LOCATION WITH DESK SUPPLIER STORE PLANNING DEPT 112 WEST 34TH STREET NEW YORK, NY 10120 L ARCHITECT: A -3 RD1 RD1 JAMES M. HAMILL, A.I.A. 580 DECKER DRIVE, SUITE 170 IRVING, TEXAS 75062 PHONE: (972) 714 -0420 PROJECT CO- ORDINATOR: A U L P A R T N E R S H I P O RD 1 NL /EM T O R O N T O • CALGARY • V A N C O U V E R 2660 Sherwood Heights Dr. Suite 200, Oakville, Ontario, L6J 7Y8 1- 888 - 855 -5061 ENGINEER fax (905)337 -1986 Emphasis On Excellence M•Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 TEL: 614.818.2323 FAX: 614.818.2337 PER GOVERNING CODE, FURNISH AND INSTALL SELF- CONTAINED BATTERY PACK EMERGENCY LIGHTING THROUGHOUT THE DEMISED PREMISES INCLUDING THE TOILET ROOMS AND STORAGE AREAS. TENANT'S LIGHTING AND LIGHTING CONTROLS SYSTEM SHALL COMPLY WITH THE WASHINGTON STATE NON - RESIDENTIAL ENERGY CODE. STOREFRONT LIGHTING MUST BE INCANDESCENT OR METAL HALIDE ON A SEPARATE CIRCUIT AND A `1 -DAY TIME CLOCK SET TO MALL'S OPERATING HOURS. COMPACT FLUORESCENT DOWN LIGHTING OR DIRECT FLUORESCENT LIGHTING WILL NOT SE ALLOWED IN STOREFRONT. ALL LIGHT FIXTURES ON PLAN SHALL BE LABELED ON MATCH LIGHT FIXTURE SCHEDULE TYPES. LIGHT FIXTURE SCHEDULE SYMBOL MANUFACTURER DESCRIPTION F1 F1 -4 F2 SIMKAR S IMKAR CH2132S11 -UNV S' - 2 LITE TANDEM FLUORESCENT STRIP C1-1132S11 -UNV 4' - 1 LITE TANDEM FLUORESCENT STRIP NNE MERCURY 54E340- 1=31AX -9 -ELS 2'x2' PARABOLIC ELECTRONIC BALLAST RECESSED FIXTURE PI-12466i 32W TS FLUORESCENT LAMP SYMBOL MANUFACTURER PH24551 32W TS FLUORESCENT LAMP F40BXSPX35 40W BIAX LAMP JBL JBL DESCRIPTION SJ -1: SUB WOOFER 5J -2: SPEAKER MONITOR REFLECTED CEILING PLAN NOTES FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. TI-118 CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS DP THE DESIGN AND 1NCLUDE IN HIS SID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE SY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL NAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDI•G_ THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. F2/EM I Fr MERCURY 54E340- BIAX- 9- ELB /EM NIGHT /EMERGENCY LIGHT 2'x2' PARABOLIC ELECTRONIC BALLAST RECESSED FIXTURE F405XSPX35 40W BIAX LAMP El HIGHLIGHT BP- PLED -S -R LED UNIVERSAL EXIT SIGN RD1 O JUNO TC920- 525C111l -1 DOWNLIGHT, WHITE FINISH PHILIPS #144752, CDM 125w/PAR35 /5P /3K. E3 JUNO CH6 -2260, 650CWH 2 -25W PLK -E COMPACT FLUORESCENT DOWNL IGHT, WHITE FINISH - PHILIPS P1-13402 ' PL -C 26W/3/4P E2 HIGHLIGHT 1-1L -90 -DL SURFACE MOUNTED EMERGENCY LIGHT - COLOR WHITE MOUNTED AT 12' -5' AFF OR MAX ALLOWABLE BY CODE A4 TF2 TF a JUNO CONTECH CON -TECH EMERGENCY LIGHT T294WI -1 PAR3S TRACKHEAD, WHITE FINISH CTL10G12WW -WT WALL WASHER, WHITE FINISH #LTSP (S' LTH) CHANNEL #LTOP (6' LTH) TRACK #LT4P (4' LTH) #LT2P (2' LTH) LIGHT FIXTURE SCHEDULE SPRING LOADED ATTACHMENT MOUNT DIRECTLY TO LAY -IN CEILING PHILIPS #144752, CDM -i 25 /PAR3S/FL /3K PHILIPS #22337, CDM- 10/T6 /S30 SD SUPPLIED AND INSTALLED SMOKE DETECTOR BY TENANT'S' G.C. BANNER TRACK SYSTEM NUTONE QTRN110L RECESSED 110 CFM FAN /LIGHT UNIT WITH (1) 100 W BULB THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS OF ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF T1-11S WORK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 2 LIGHTING SHALL BE CIRCUITED EXACTLY AS SHOWN ON PLANS. 3. GENERAL CONTRACTOR TO INSTALL TENANT FURNISHED CRUSH GUARD SAFETY SLEEVES TO ALL STOCKROOM FLOORESCENT LIGHTING. 4. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION AND QUANTITY OF LIGHTING FIXTURES. S. EMERGENCY AND EXIT LIGHTS SHALL BE INSTALLED AND CIRCUITED PER THE LATEST NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES_ ALL EMERGENCY AND EXIT FIXTURES SHALL BE DUAL VOLTAGE (120/211 VOLT INPUT) WITH BATTERY BACKUP. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. 0 TENANT E.C. TO FURNISH AND INSTALL CONDUIT AND PULL WIRE TO ALL A/V LOCATIONS AS REQUIRED BY A/V VENDOR. CONFIRM REQUIREMENTS AND LOCATIONS WITH OWNER PRIOR TO BID. SEE DETAIL K ON SHEET E1.1. 2 OWIRE THROUGH A 6 POLE CONTACTOR CONTROLLED BY A TIME SWITCH. CONTACTOR AND TIME SWITCH SHALL BE AS SPECIFIED IN SPECIFICATIONS AND MOUNTED ADJACENT TO LIGHTING PANEL. REFER TO SHEET E3.0 AND SPECIFICATIONS FOR MORE INFORMATION. OHOMERUN THROUGH A 2 POLE CONTACTOR CONTROLLED BY SWITCH "c ". CONTACTOR SHALL BE AS SPECIFIED IN SPECIFICATIONS AND MOUNTED ADJACENT TO LIGHTING PANEL. SEE MASTER LIGHTING SWITCH BANK DETAIL ON THIS SHEET AND "POWER RISER" ON SHEET E3.0. HOMERUN THROUGH A 2 POLE CONTACTOR CONTROLLED BY SWITCH "b ". CONTACTOR SHALL OBE AS SPECIFIED IN SPECIFICATIONS AND MOUNTED ADJACENT TO LIGHTING PANEL. SEE MASTER LIGHTING SWITCH BANK DETAIL ON THIS SHEET AND "POWER RISER" ON SHEET E3.0. 5 HOMERUN THROUGH A 4 POLE CONTACTOR CONTROLLED BY SWITCH "c ". CONTACTOR SHALL BE AS SPECIFIED IN SPECIFICATIONS AND MOUNTED ADJACENT TO LIGHTING PANEL. SEE MASTER LIGHTING SWITCH BANK DETAIL ON THIS SHEET AND "POWER RISER" ON SHEET E3.0. HOMERUN THROUGH A 4 POLE CONTACTOR CONTROLLED BY SWITCH "d ". CONTACTOR SHALL OBE AS SPECIFIED IN SPECIFICATIONS AND MOUNTED ADJACENT TO LIGHTING PANEL. SEE MASTER LIGHTING SWITCH BANK DETAIL ON THIS SHEET AND "POWER RISER" ON SHEET E3.0. O OCONNECT EXIT, EMERGENCY, AND NIGHT LIGHTING FIXTURES TO NL /EM /EX CIRCUIT IN NON— SALESAREA #A -28, IN SALES AREA #A- 26(TYPICAL). PROVIDE SCREW TYPE LO'S AT THE BREAKER. CIRCUIT TO UNIT EQUIPMENT EMERGENCY LIGHTING MUST COMPLY WITH N.E.C. ARTICLE 700 -12E. cg) LIGHTING SWITCH BANK TO BE LOCATED AT REAR DOOR TO SALES AREA. SEE DETAIL '5' ON THIS SHEET. EMERGENCY LIGHTS TO BE INSTALLED ON SEPARATE CIRCUIT. SMOKE /HEAT DETECTOR SPACING SHALL COMPLY WITH THE REQUIREMENT OF NFPA 12 -E. THE INSTALLING CONTRACTOR SHALL SUBMIT A CEILING PLAN SHOWING THE LOCATION OF THE DETECTORS TO THE FIRE MARSHALL FOR APPROVAL BEFORE STARTING WORK, IF REQUIRED BY LOCAL AUTHORITIES. REFER TO FINISH SCHEDULE SPEC 4 INTERIOR ELEVATIONS FOR FINISHING 4 PAINTING REQUIREMENTS. THE POSITION OF THE TRACK 15 TYPICALLY SET OUT FROM PERIMETER WALL AS INDICATED. UPON COMPLETION OF JOB, CONTRACTOR SHALL BALANCE THE AIR AND SUBMIT CERTIFIED COPY OF AIR BALANCE REPORT TO THE TENANTS PROJECT MANAGER G_C. TO ADVISE TENANT PROJECT MANAGER OF MAX CLEAR HEIGHT IN STOCK ROOM PRIOR TO PROJECT COMMENCING_ THIS IS TO ALLOW THE HEIGHT OF THE STOCK ROOM SHELVING TO BE MAXIMIZED GC. SHALL FIELD EXAMINE THE CONDITION OF EXISTING TENANT DEMISING PARTITIONS 4 EXTERIOR GLAZING WALLS AND PROVIDE FULL HEIGHT 4 FINISHED PARTITION TO UNDERSIDE OF ROOF DECK AS REQUIRED. ALL EXPOSED PARTITIONS AT SALES AREA MUST SE TAPED, SPACKLED AND PAINTED IN THEIR ENTIRETY. FIRE SPRINKLER SYSTEM: EXISTING SPACE FIRE SPRINKLER SYSTEM TO BE MODIFIED PER NEW TENANT SPACE DRAWINGS AS REQUIRED BY NFPA STANDARDS AND LOCAL CODES. ALL AREAS TO BE ORDINARY HAZARD GROUP II OCCUPANCY WITH FIRE SPRINKLER FABRICATION DRAWINGS TO BE SUBMITTED BY TENANT FIRE PROTECTION CONTRACTOR TO BUILDING DEPARTMENT BEFORE WORK COMMENCES. ALL SPRINKLER HEADS WILL BE SEMI - RECESSED CHROME TYPE CENTERED IN 2X2 CEILING GRID. SPRINKLER HEADS - NOTE: SYMETRICAL PATTERN TO ALIGN W/ CEILING ELEMENTS. REFLECTED CEILING PLAN NOTES L(30‘84 - SALES AREA SALES AREA DATE SALES AREA 04/04/8 SALES AREA CLIENT COMMENTS 2. REVISED AS PER 06/02/8 CLIENT COMMENTS ® (-4-) ® O FLUOR LIGHTS FLUOR LIGHTS ,ibi, TRACK L IGNTS iicii TRACK LIGHTS d 025 REVISION NOj_ RECEIVED JUN 0 9 2008 PERMIT CENTER LIGHTING GENERAL NOTES LIGHTING CODED NOTES MASTER LIGHTING SWITCH BANK PASZ DATE: SCALE: GROSS AREA: SALES AREA: PROJECT # : DRAWN BY: 12/17/07 AS NOTED 2,164 SQ. FT. 1,272 SQ. FT. 0712260 Lady Foot Locker PROJECT TITLE SOUTHCENTER MALL 304 SOUTHCENTER PKWY TUKWILA, WA, 98188 SPACE #1560 STORE No. 46171 SHEET TITLE ELECTRICAL LIGHTING PLAN SHEET NO. E2.0 REVISIONS NO. DESCRIPTION DATE 1. REVISED AS PER 04/04/8 LANDLORD AND CLIENT COMMENTS 2. REVISED AS PER 06/02/8 CLIENT COMMENTS DATE: SCALE: GROSS AREA: SALES AREA: PROJECT # : DRAWN BY: 12/17/07 AS NOTED 2,164 SQ. FT. 1,272 SQ. FT. 0712260 Lady Foot Locker PROJECT TITLE SOUTHCENTER MALL 304 SOUTHCENTER PKWY TUKWILA, WA, 98188 SPACE #1560 STORE No. 46171 SHEET TITLE ELECTRICAL LIGHTING PLAN SHEET NO. E2.0 1 Panel Wiring Schedule (3- Phase) Panel Wiring Schedule (3- Phase) Panelboard "A" Voltage 208Y/120 Phase 3 Options/Notes Panelboard "H" Voltage 480Y/277 Phase 3 Options /Notes FOOT LOCKER INC. STORE PLANNING DEPT 112 WEST 34TH STREET NEW YORK, NY 10120 Panel Type NQOD OCPD 150A M.C.B. Wire 4 Panel Type NQOD OCPD 100A M.C.B. Wire 4 ARCHITECT: JAMES M. HAMILL, A.I.A. 580 DECKER DRIVE, SUITE 170 I RVI N G TEXAS ' 75062 PHONE: (972) 714 --0420 NEMA Type 1 Mounting SURFACE Buss 225A AIC Rating 10,000 NEMA Type 1 • Mounting SURFACE Buss 100A AIC Rating 18,000 Ckt. No. Zone Load Description Brkr. Size * Brkr. Opts. N.E.C. kVA "" Phase N.E.C. kVA ** Brkr. Opts. Brkr. Size * Load Description Zone Ckt. Ckt. No. No. Zone Load Description VAV -1 Brkr. Size * 20/3 Brkr. Opts. N.E.C. kVA ** 3.000 Phase A N.E.C. kVA ** 8.704 Brig. Opts. Brkr. Size * 70/3 Load Description Zone Ckt. No. 2 ELECTRIC LOAD SUMMARY (TRANSFORMER) 208Y/120V LOADS DESCRIPTION N.E.C. CONNECTED kVA NEC DEMAND NOTES N.E.C. DEMAND FACTOR N.E.C. DEMAND kVA 1 SIGN LO 1.200 A 1.200 SALES TRACK 2 1 3 STORE FRONT LTS Lo 1.375 B 1.500 SALES TRACK L 4 3 HACR 3.000 B 8.215 TRANSFORMER / i \ 4 LIGHTING (CONTINUOUS) TRACK LIGHT DEMAND ALLOWANCE SHOW WINDOW DEMAND ALLOWANCE 15.731 - [1] [2] [31 1.25 - 19.664 0.000 2.000 Q 5 NON -SALES LIGHTS 0.74D C 1.200 SALES TRACK 6 5 3.870 C 8.212 6 7 STORE FRONT TRACK 1.$00 A 1.500 SALES TRACK H 7 VAV -1 1.667 A 0.000 8 9 S.F. RECEPTACLES 0.720 B 1.350 SALES TRACK 10 9 20/3 HACK 1.667 B 0.000 10 KIT APPLIANCE 0.000 [4 1.00 0.000 11 N.S. RECEPT. 0.900 C 1.052 SALES LTS 12 11 2.367 C 0.000 12 RECEPTACLES MOTORS 4.700 0.000 [5] [6] - - 4.700 0.000 13 SALES RECEPT. 0.720 A 1.014 SALES LTS , /� 14 13 0.000 A 0.000 14 15 TELEPHONE BOARD 0.100 B 2.300 30/2 WATER HEATER 16 15 0.000 B 0.000 16 FIXED ELECTRIC SPACE HEATING AIR CONDITIONING SYSTEM ELECTRIC WATER HEATER - - MISCELLANEOUS 0.000 0.000 4s00 -- 0.100 25.131 [6],[7] [61•[7] [s[ - - - - - 1.0 - - - 1.0 0.000 0.000 5.750 -- - - 0.100 - - - 32.214 17 PANIC /BUZZER. 0.100 C 2.300 18 17 0.000 C 0.000 18 19 CASH REGISTER 0.360 A 0.100 Lo FIRE ALARM PNL 20 Breaker Options: 21 CASH REGISTER 0.360 B 0.000 SPARE 22 Notes 23 CASH REGISTER 0.360 C 0.000 SPARE 24 * All circuit breakers to be 20 -Amp, 1 -Pole unless otherwise noted. AS Powerlink AS Breaker LO Handle lock -on device ST Shunt Trip Type AUX Auxiliary Contacts PA Handle Padlock Attachment GFCI Ground Fault Circuit Interrupter 25 CASH REGISTER 0.360 A 0.450 LO EM/NUEX LTS 26 '* All Phases to be balanced to within 10% using Actual Load Totals. N.E.C. DEM. KVA X 1000 = MINIMUM FEEDER AMPERAGE /1V ` 27 SOUND SYSTEM 0.360 B 0.150 Lo EM /NUEX LTS Q 28 N.E.C. Connected Totals: Ph A 13.371 A PROJECT CO- ORDINATOR: = •K ' P A U L P A R T N E R S H T P ,; T o Ro NT0 • CALGARY • VANCOUVER _ 2660 Sherwood Heights Dr, Suite 200, Oakville, Ontario, L6J 7Y8 1- 888 - 855 -5061 fax (905)337 -1986 29 MANAGER'S COMPUTER 0.360 C 1.200 Lo SIGN 30 N.E.C. Connected Totals: Ph.B 12.882 kVA SYS. VOLTAGE X 1.732 32.214X1000 = 89.4 AMPS n 31 SPARE 0.000 A 0.000 SPARE 32 N.E.C. Connected Totals: Ph.0 14.449 kVA 33 SPARE 0.000 B 0.000 SPARE 34 Total 40.702 kVA 1 208 X 1.732 35 SPARE 0.000 C 0.000 SPARE 36 E Existing Circuit to remain HACR Heating, A/C & Refrigeration SF Subfeed AFCI Arc Fault Circuit Interrupter ELECTRIC LOAD SUMMARY 480Y/277V SYSTEM ■ Electrical for shall. utilize landlord Rased disconnect switch Io d within the Tenant spacer On befit wok, for temporary. electrical for DdnS17UCtiOft. EI�IC l contractor shall provide temporary r and palm as required Within Tenant ■ tendloi+li.prov deb main dammed means far Tenant hi n Landlord Beotll+ai itoam as well as c ntidult and conductors {feeder) from the matln connect means to a Landlord pror[ded fused dl&conneet switch located within the Tenant space. If needed to accommodate Tenant ten, the Tenant stall ralvciite the Landlord provided discannerct swftdi rid associated feeder. Tenant sha1I.iurnlsh and ill tandult and conductors from fused *Canned switch to Tenants' ,Hain feed disconnect switch or mail I t breaker equipped pr3nelboard. 37 SPARE 0.000 A 0.000 SPARE 38 IG Isolated Ground Circuit Connected Load: 49.0 amps 39 SPARE 0.000 B 0.000 SPARE 40 NEC 2005 Demand Feeder Load: 57.5 amps 41 SPARE 0.000 C 0.000 SPARE 42 DESCRIPTION N.E.C. CONNECTED kVA NEC DEMAND NOTES N.E.C. DEMAND FACTOR N.E.C. DEMAND kVA Notes Breaker Options: LIGHTING (CONTINUOUS) TRACK LIGHT DEMAND ALLOWANCE _. --- -- SHOW WINDOW DEMAND ALLOWANCE 15.731 - [1] (21 [3] 125 - - 19.664(w 0.000 - A 2.000 * All circuit breakers to be 20 -Amp, 1 -Pole unless otherwise noted. AS Powerlink AS Breaker All Phases to be balanced to within 10% using Actual Load Totals. LO Handle lock -on device 1 N.E.C. Connected Totals: Ph.A 8.704 A ST Shunt Trip Type N.E.C. Connected Totals: Ph.B 8.215 kVA AUx Auxiliary Contacts N.E.C. Connected Totals: Ph.0 8.212 kVA PA Handle Padlock Attachment - - - - -- - - - -- - -- - KIT APPLIANCE RECEPTACLES MOTORS FIXED ELECTRIC SPACE HEATING - - --- - -- - 0.000 4.700 O..57 15.571 -- - -- - - [4 [51 - [6] [61.171 - -- - - -- - - -- -- 1.00 - - - 0.000 4.700 - - o.000 15.571 Total 25.131 kVA GFCI Ground Fault Circuit Interrupter E Existing Circuit to remain HACR Heating, A/C & Refrigeration IG Isolated Ground Circuit Connected Load: 69.8 amps SF Subfeed NEC 2005 Demand Feeder Load: 89.4 amps AFCI Arc Fault Circuit Interrupter AIR CONDITIONING SYSTEM 0.000 [6],[7] - 0.000 ELECTRIC WATER HEATER 4.600 [81 1.D 5.750 MISCELLANEOUS 0.100 1.0 0 100 A ENGINEER TOTAL 40.702 TOTAL 47.785 L1 N.E.C. DEM. KVA X 1000 = MINIMUM FEEDER AMPERAGE SYs. VOLTAGE X 1.732 47.785 X 1000 = 57.5 AMPS 480 X 1.732 ■ Landlord provided master rn[etertnp equipment in the Lar diordB Electrical ROOM. The Landlord - Emphasis On Excellence M Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 TEL: 614.818.2323 FAX: 614.818.2337 LOAD SUMMARY NOTES: [1] POWER FACTOR IS ALREADY INCLUDED IN LIGHTING LOAD. [2] 150VA/2FT OF LINE VOLTAGE TRACK + SUM LOW VOLTAGE XFRMS - CONNECTED LOAD [3] 200VA/LF - ACTUAL CONNECTED LOAD [4] KIT APPLIANCE DEMAND FACTOR PER NEC 220-20 [5] 0.0 < 10KW - 100 %, REMAINING - 50% awned network metering system will meter tenant power consumption. • Tenant's Meanitel contractor shall furnish an ide>r ltatkin nameplate on Tenant's main disconnect sywItci1 In Lark/lord's switchboard. 1' amepiates shall be one-eight Inch (1/8') thick plastic, black on White and etched letters, 1tte're nimurf Min shalt be one Inch (V'} with only the Tenant's space number engraved en such, permanently affixed. HVAC CONNECTION SCHEDULE EQUIP. NAME VOLTAGE FLA /HP/KW WIRE CONDUIT DISCONNECT CIRCUIT (6] 125% OF THE LARGEST MOTOR OR COMPRESSOR IN SYSTEM APPLIED ON ONE UNIT. [7] USE GREATER VALUE OF THESE TWO CATEGORIES [8] 125% DEMAND FACTOR FOR TANK TYPE, 100% FOR INSTANT HOT • Tenar►t shell icrrrrlsh end irtdli611 duct 1iet�ctars > renm#a Fkfllts[li and LED [ttdlGil>73T p[lht in ztpply aerod n stern males far each T echo vAAV tallies required 1 Cade and lr clic tathloeity having jurisdiction. , VAV -1 4SIDV 30 NEW gKW HEAT NEW 3#12THWN 4 1#12GRD NEW 3/4" NEW BOA NON -FUS. DISC. SW. H -1/3/5 minimum building wire sib shed be #1Z AWE; etcduding €grrtt>al wiring per, • Ali building wiring strati be capper with typtt'ilhrr TFIW, TWAIN or TWIN II1Btt13C14r1• • No AC or l�hamex type wiring allowed. ■ Na attachment or support tram any roof' deck Is allowed. Hangers, dernps and supports shall be fastened to bar joists or beams only. • All cabling shall be plenum rated. AlI Tenants served by LandIO a conditioning sarong have plenum retuma, Q • IrhstaII a complete type mitten klentlfiteliert directory card for all branch clrxults In the electrical panel door. Na pede:st�il security systems will be a®elwed. Linder type will be acceptable. • Provide complete s �°ns' SFOCt �� N p,1<A�Ce ope .... - 1�0��' WIN 1 u 1U �, 1 ICI* 48mv, 3PH DELTA -�u 1�� 3P1-I, 4W WYE SEC. TO BE VERIFY EXACT Cl G � 15 PRIOR TO BIDS. 2 • S �- Y - ' P�� c F _` � ',NA---4- ' 6611 M1 O 1 �s ' . , . '-� j ��- ��•. _.. �: �4 -4it. toNi,.�' ` °` r r�ti 3 O ,i - VAV -2 480V 30 NEW 5KW HEAT NEW 3 #12T1 -IWN 4 1 012GRD NEUJ 3/4 NEW BOA NON -FUS. DISC. $W. H- 1/9/11 NOTE: VERIFY EXACT OVER CURRENT PROTECTION DISCONNECT REQUIREMENTS (PER NEC #440) WITH EQUIPMENT / � # ) MANUFACTURER NAMEPLATE DATA FURNISHED WITH UNIT /MECHANICAL CONTRACTOR PRIOR TO ELECTRICAL ROUGH -IN. MAKE ALL FINAL ELECTRICAL POWER CONNECTIONS. FURNISHED AND INSTALLED BY LANDLORD. LL'S ELECTRICAL LEASE LINE LADY FOOT LOCKER SPACE ROOM 2 SPACE ..- REFER TO HVA,G CONNECTION SCHEDULE FOR -^ CIRCUITING/WIRE SIZE /CONDUIT SIZE OF ALL HVAC EQUIPMENT_ 45KVA TRANSFORMER REVISIONS NO. DESCRIPTION DATE 1 . REVISED AS PER 04/04/8 LANDLORD AND LL. TO PROVIDE 2" CONDUIT AND 4 #3/0 THWN AND 1 # ' GRD.. - VERIFY EXACT REQUIREMENTS IN FIELr PRIOR TO BIDS. TENANT E.C. TO PROVIDE PRI. 120/20SV, 3 03 THUN AND 1 *8 GRD- RELOCTED. FIELD 7.4ND 1 -1/4" CONDUIT REQUIREMENTS D TENANT CLIENT COMMENTS 2. REVISED AS PER 06/02/8 TENANTS ELEC. CONTRACTOR To PROVIDE J -BOX AS NEEDED. TENANTS ELEC. CONTRACTOR TO O E.G. TO PROVIDE THIN AND 1 0' AND 2° CONDUIT 1 CLIENT COMMENTS E4.0 4 01/0 G. EXTEND PANEL AND TIT 1ECLOCK FOR STOREFRONT LIGHTING-,: TO CIRCUITS INDICATED ON PLANS. C a. LL. TO PROVIDE METER IN LANDLORD PROVIDED METER SOCKET. ~�46.. LANDLORD SHALL PROVIDE 100A/3P CIRCUIT BREAKER IN CONDUIT AND WIRE NEEDED.I AS PANEL 0 -1 277/480V 304W 100A M.C.B. 120/208V 304W 150A M.c.B. v , TENANT EC. TO PROVIDE "6 CaRD- TO BUILDING STEEL PER N.E.C. 1 C f DATE: 12/17/07 JD 100A C c f A SCALE: AS NOTED LANDLORD'S SWITCH GEAR_ EXISTING 2-11/480V, 3?, 4W, LANDLORD METER PANEL ' s GROSS AREA: 2,164 SQ. FT. cn c TO CIRCUITS INDICATED ON PLANS. SALES AREA: 1,272 SQ. FT. PROJECT # : 0712260 BOARD- FIELD VERIFY EXACT REQUIREMENTS PRIOR TO BIDS. --------� FLOOR DRAWN BY: FIELD VERIFY EXACT DISTANCE Lady Foot L EXISTING POWER RISER AND SCHEDULES N.T.S. I 4 y LI E 3 r i a A i 7 r9 i s 3. 1. HVAC CIRCUIT BREAKERS SHALL BE "HACK" TYPE WHERE REQUIRED BY EQUIPMENT NAMEPLATE PER N.E.C. 2. TENANTS ELECTRICAL CONTRACTOR SHALL FIELD VERIFY EXACT A.I.C. RATING OF LANDLORDS DISTRIBUTION EQUIPMENT, FURNISH AND INSTALL TENANTS SYSTEM TO MATCH. 3. ELECTRICAL CONTRACTOR SHALL BALANCE ALL PANELS AND ELECTRICAL EQUIPMENT TO 10% BETWEEN PHASES: A /B, 13/C, A/C REGARDLESS OF CIRCUITING INDICATED. 4. PROPER CLEARANCE MUST BE MAINTAINED ABOUT ELECTRICAL EQUIPMENT PER N.E.G. FIELD VERIFY EXACT MOUNTING SPACE AVAILABLE IN ELECTRICAL ROOM /AREA PRIOR TO INSTALLATION OF ELECTRICAL EQUIPMENT. 5. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL CONNECTIONS FOR A COMPLETE ELECTRICAL DISTRIBUTION SYSTEM. 6. BOND NEUTRAL TO GROUND AT DISCONNECT SWITCH IF NOT BONDED ON LINE SIDE OF DISCONNECT SWITCH. IF NEUTRAL 15 BONDED ON LINE SIDE OF DISCONNECT SWITCH, Do NOT BOND AT DISCONNECT SWITCH. 1. MAXIMUM LENGTH OF TAP CONDUCTORS ON TRANSFORMER SECONDARY SHALL NOT EXCEED lm' -ID" IN LENGTH_ 8. FIELD VERIFY EXACT MOUNTING SPACE AVAILABLE IN ELECTRICAL ROOM /AREA PRIOR TO INSTALLATION OF ELECTRICAL EQUIPMENT. EQUIPMENT NAMEPLATE PER N E.G. PROJECT TITLE SOUTHCENTER MALL 304 SOUTHCENTER PKWY TUKWILA WA 981 88 3 3 SPACE #1560 STORE NO. 46171 FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. T1-115 CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, INTERPRETATIONS AND GLARIi= 1GATDIONIS OF HE DESIGN AND INCLUDE IN HIS Blp ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. •- SHEET TITLE ELECTRICAL POWER RISER & SCHEDULES '� RECEIVED \IQIM Mn . 1 JUN 09 3•0 ; t W POWER RISER GENERAL NOTES NIPIda Phi-Nil �kll�li -- SECONDARY PRIMARY REGISTER REGISTER FOOT LOCKER, INC. STORE PLANNING DEPT WEST 34TH STREET NEW YORK, NY 10120 ARCHITECT: JAMES M. HAMILL, A.I.A. 580 DECKER DRIVE, SUITE 170 IRVING, TEXAS 75062 PHONE: (972) 714 -0420 INSTALL ETHERNET CABLE THRU DATA CONDUIT INTO CASH WRAP. lii RJ -45 (MALE) PROJECT CO- ORDINATOR: 4 `K P A U L P A R T N E R S H I P r u '�` TORONTO • CALGARY • VANCOUVER 2660 Sherwood Heights Dr. Suite 200, Oakville, Ontario, L6J 7Y8 1-888-855-5061 fax(905)337 -1986 - CASH WRAP MANA ER 1 DESK ,e CABLE BLOCK WIRING DIAGRAM 3" GROMMET HOLE 3" GROMMET HOLE 3" GROMMET HOLE 3" GROMMET HOLE CTYP.) (TYP) CTYPJ (TYP.) ENGINEER ■ Emphasis On Excellence M•Retail Engineering, Inc. 750 Brooksedge Blvd, Westerville, Ohio 43081 TEL 614.818.2323 FAX: 614.818.2337 TYPICAL V. QC,�' $G .tip �al��° '' °I�", � �_... w •N. . gyp - <. " .E,-,?," F...'‘;JAl;• ": . 4�4 07 i 11 / ;s9 ate-" SECONDARY REGISTER WELL (3) (4ro84) i PRIMARY RECD ER REGISTER WELL C 1) (46&4) SECONDARY / PRIMARY REGISTER WELL C U / REGISTER WELL \I il (3) wii�rr�r�rrri� ACCESS POINT j (4ro84) (4e,04) `� lv�.►i�i �ii�.r�. / WOOD SHELF G.C. CONNECT 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _ �l 11. _____ 3" GROMMET IN TOP OF COUNTER qIN A FOR 4/V SYSTEM. VERIFY EXACT — PRINTER ACCESS POINT VI PROVIDED LIGHT FIXTURE DUPLEX OUTLET FOR SECURITY B o LOCATION WITH A/V CONTRACTOR. REVISIONS NO. DESCRIPTION DATE 1. REVISED AS PER 04/04/8 JACK A LANDLORD AND RJI1C PHONE JACK RAC PHONE (LINE I) (LINE 1) CONTRACTOR TO FURN. AND INST. CONTRACTOR. TO FURN. AND INST. FOUR (4) 1" CONDUITS TO WRAPPER: FOUR (4) 1" CONDUITS TO WRAPPER= LAMINATED MGR. DESK CLIENT COMMENTS MANAGER'S DUPLEX OUTLET DUPLEX OUTLET RECEPTACLE 2. REVISED AS PER 06/02/8 DESK RECEPTACL � CLIENT COMMENTS 1. FOR TELEPHONE 1. FOR TELEPHONE rrr,,/wri�././s�i�i���e BUZZER 2. FOR ETHERNET CABLE 2. FOR ETHERNET GABLE 3. FOR DEDICATED ELECTRICAL OUTLETS 3. FOR DEDICATED ELECTRICAL OUTLETS o ! 4. FOR GENERAL ELECTRICAL POWER 4. FOR GENERAL ELECTRICAL POWER CONTRACTOR TO FURN. AND INST. ONE CONTRACTOR TO FURN. AND INST. ONE DEDICATED CIRCUIT (SEPERATE HOT, NEUTRAL, DEDICATED CIRCUIT (SEPER4TE HOT, NEUTRAL, 120 VOLT, 20 AMP CIRCUIT WITH QUAD OUTLET 120 VOLT, 20 AMP CIRCUIT WITH QUAD OUTLET �� UNDER EACH WELL, 2 HUBBEL I.G.°53 '2 OR UNDER EACH WELL, 2 HUBBEL I.G. 5352 OR APPROPRIATE EQUIVALENT, WIRED TO PANEL BOARD APPROPRIATE EQUIVALENT, WIRED TO PANEL BOARD CONTRACTOR TO FURN. AND INST. ONE CONTRACTOR TO FURN. AND INST. ONE DATE: 1 �`�- SCALE: AS NOTED NON - DEDICATED DUPLEX OUTLET, WIRED TO NON- DEDICATED DUPLEX OUTLET, WIRED TO PANEL BOARD. PANEL BOARD. RJ11G PHONE JACK (LINE 1) GROSS AREA: 2,164 SQ. FT. SALES AREA: 1 ,272 SQ. FT. DEDICATED QUAD OUTLE 1 RECEPTACLE FOR PRINTER SYSTEM. PROJECT # : 0712260 DRAWN BY: A (2) TWO CASH REGISTER WIRING DETAIL B MANAGER DESK WIRING DETAIL Lady Foot Locker A NVro4BUILT COORDINATE SPACING OF LINTELS IN ORDER THAT THE CHANNELS UNDER THE TRANSFORMER ARE FIRMLY SUPPORTED ON AND ATTACHED SECURELY TO THE -UP LINTELS. �— BUILT –UP LINTELS CONSISTING OF (2)4° 16 PULL CORD STATION SEE FLOOR PLAN FOR LOCATION. EDWARDS #6531 1. CONTRACTOR SHALL INSTALL AN ETHERNET GABLE (TWISTED SHIELDED CABLE) FROM TI-4E MANAGER'S DESK TO CASH WIRAP THRU DATA CONDUIT, AND TERMINATE CABLE IN CASH WRAP. C NOTE DO NOT TERMINATE CABLE NEAR OR ON METAL POLESF ®NC.� OR RACKS. �, �►C °M. ° tleC� 2. LABLE CABLE AT MANACsER'S DESK AS 'ACCESS POINT'. ®��Q�7® �� 3. CONTRACTOR SHALL INSTALL CABLE LEAVING ANY AND ALL ' SLACK COIL IN MANAGER'S AREA WITH A MINIMUM OF 12 SLACK �� ' A/ AT CASH WRAP_ \�a I„ .;i1�. I I ,i�'� `'� I ( I1 !, GA. STUDS ATTACHED AT 12" O.C. TO (2)4" 16 GA. TRACKS. 1" PROVIDE 1 DIAGONAL STEEL STRAP BRACING ATTACHED TO BUILT–UP COLUMNS �� 4. MATERIALS TO BE SUPPLIED BY FOOT LOCKER � 10% NOTE: IF FOOT LOCKER SUPPLIED ETHERNET CABLE EXCEEDS 15' -ID" �.. FROM MANAGER'S DESK TO CASH WRAP, CONTRACTOR TO SUPPLY REPLACEMENT CABLE AS NEEDED, AND RETURN UNUSED GABLE BACK TO CABLE COMPANY. 5. CONTRACTOR SHALL MAINTAIN A MINIMUM CLEARANCE OF 1S INCI -4ES FROM ALL NOISE EMANATING ELECTRICAL EQUIPMENT (e.c�. BALLASTS, POWER FEEDER CABLES, ETC.) FOR ENTIRE CABLE RUN. 6. CONTRACTOR SHALL PERFORM A CONTINUITY CHECK FOR EACH CONDUCTOR TERMINATED AT EACH END OF THE INSTALLED GABLES, INCLUDING CABLE SHIELD. 1. CONTRACTOR 5HALL LEAVE ONE AS BUILT COPT OF THIS PROJECT TITLE SOUTHCENTER MALL 304 SOUTHCENTER PKWY TU KWI LA WA 98188 SPACE # 1560 STORE NO. 461 71 ►� �F ' BUILT –UP COLUMNS CONSTING OF (2)4" 16 GA. STUDS ATTACHED AT 12" O.C. TO • (2)4" 16 GA. TRACKS. . CONNECT TO NEAREST 120V, CONVENIENCE RECEPTACLE CIRCUIT. 24V SEC �:4UIDIBLE ALARM STROBE, 06536 a ,;ilk. 1111 "x4 "x4" ATTACHED N EDWARDS -G5 12IDV TO 24V SYSTEM TRANSFORMER IN NEMA 1 ENCLOSURE. EDWARDS X552 CALL FOR ASSISTANCE NOTE: PROVIDE 4 STEEL ANGLE - A D TO BUILT UP COLUMNS AND NCHORE 41b ■ TO THE FLOOR SLAB. c 3 3 5/8" 16 GA STUDS AND TRACKS CAN BE SUBSTITUTED FOR 4" COMPONENTS IN ORDER TO ENCLOSE THE STRUCTURE WITHIN PARTITION CONSTRUCTION. a ALL MEMBERS OF BUILT -UP LINTELS AND COLUMNS MUST BE ATTACHED AT 12" O.C. AND AT ' ENDS. DRAWING WITH STORE MANAGER(S). .. REvisION NO 1.1-- RECEIVED JUN 9 9 SHEET TITLE M ISCELLANEOUS ELECTRICAL DETAILS INSTALL AN EDWARDS MODEL °ro53S -G5 CALL FOR ASSISTANCE SYSTEM AS SHOWN, INCLUDING EDWARDS *'6531 PULL CORDS AT NEAR THE TOLIETS, *5'92 TRANSFORMER, ''ro536 -G5 HORN /STROBE OUTSIDE THE RESTRODMS WHERE INDICATED. VERIFY MOUNTING HEIGHTS AND REG2UIREMENTS PRIOR TO BIDDING. SHEET NO. • 40 D TRANSFORMER MOUNTING DETAIL CALL FOR ASSISTANCE DETAIL 6 GENERAL NOTES i NEW TOILET NEW EXIT ALCOVE 110 IV FOOT LOCKER, INC. STORE PLANNING DEPT 112 WEST 34TH STREET NEW YORK, NY 10120 ARCHITECT: JAMES M. HAMILL, A.I.A. 580 DECKER DRIVE, SUITE 170 IRVING, TEXAS 75062 PHONE: (972) 714 -0420 Mz.m ROOM init.„„,,,„ are ID LOCATED ABOVE TOILET ROOM IN NIGHER CEILING, • d Ifillaire ,.), ,...., 00 RO' JE C T CO-ORDINATOR: P. KP A U L P A R T N E R S H I P ; - T O R O N T O • C A L G A R Y • V A N C O U V E R s� 2660 Sherwood Heights Dr. Suite 200, Oakville, Ontario, L6J 7Y8 1-888-855-5061 fax (905)337 -1986 -4 ~~ r .,. n • � ■A EW ELECTRICAL PANELS ; I §, 0:::: © E1RG-1 ■ _ ■kili NE ,,,,,6,1195 CONFIRM LOCATION _ ® _ k � 1 I-I _ 0 ~ ■ I ■ ■.a ■I — ~ ° NEW FITTING }ZOOM AND ACCESSORIES —■ �! • I VAV -2 tI • 0 0 ® • 0 01/111 r _ �I 0 . . 1�I11 -1 (* 6 Pm ( I ® 0 ,n O1 S 10 "0 b1hI1•iI• ■�1■ ■11■ 1 I I I I 400 1 -1 a ~ 10 :1 -1 11 _ _� V-12 O 3D 1 �_ P) O r�Tl .-12 .vci..:r sSYii LANDLORD DUCT (13'4," MIN- AFF -) - 4 \ I , • SG \ ■ T� ■ / 175 ■ �� 0 0 rr '�`�N 14/12 DUCT AT 13'0 "° AFF L J 10/12 VAV-1 SD-1 5D 325 325 ENGINEER 10" DUCT AT IV O"' ° a* I a l EW BACKWRAP AND �- V L� _/ 20/12 CASHWRir 0 ���.�� ■ 5G -1 I I 5G -1 • lir 12/12 0 12 0 M2.0 (TyF. 0 �! 1�o NEW STOREFRONT AND GLASS DOORS : — E \NED ��E �9+ COD �' ®�p tiEC A �UL 11 20 ------.100 . $3 0 �® ..� 115 115 0 �1 r,,-2 ���J I ■ ■ lauc • 6" 'l' DUCTWORK AT �' . DUCT AT Ir6 a� Emphasis On Excellence M" Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 TEL 614.818.2323 FAX: 614.818.2337 -I I' 0 • L7 N C\vAV 5 /1400 5D -1 O "� M2.m (TYP) WN , 0 0 0 325 I I I I O C • 1111 I 0 Pe 1 -� 2 ■ M2.0 (TYP) ■ • / RG-1 0 0 SEAL T- `o A , �_ i_ - - ,b__ :354 .- ' ?tee' - LANDLORD DUCT (13' -6" MIN. AFF.) ALL ROOFING WORK SHALL BE PERFORMED BY THE LANDLORD'S CONTRACTOR AT THE TENANT CONTRACTOR'S EXPENSE, IN ORDER TO MAINTAIN THE WARRANTY AND INTEGRITY OF THE ROOF SYSTEM. THIS CONTRACTOR SHALL ENSURE THAT ALL EQUIPMENT, PIPING AND DUCTWORK, NOT SHOWN TO REMAIN 15 FULLY REMOVED AND NOT ABANDONED. C.'crY.K .c:; 07 / 11 / 09 I REVISIONS LANDLORD COMMENTS: TENANT SHALL MAINTAIN A MINIMUM OF 6" UNOBSTRUCTED CLEARANCE HEIGHT IN RETURN AIR PLENUM ABOVE CEILING ALLOWING FOR AIRFLOW BACK TO LANDLORD AIR CONDITIONING SYSTEM. NO EQUIPMENT OR DUCTWORK CAN BE ATTACHED DIRECTLY TO THE SLAB OR ROOF DECK. MAXIMUM LENGTH OF FLEX DUCT IS 5' -0" LANDLORD PROVIDED TENANT FIRE SERVICE MAIN WITH BRANCH PIPING STUBBED INTO EACH TENANT'S SPACE. LANDLORD'S SPRINKLER SYSTEM 15 DESIGNED PER ORDINARY HAZARD GROUP 2 AND THE LATEST REQUIREMENTS OF NFPA -13. NO ISOLATION VALVES WILL BE PROVIDED OR PERMITTED. TENANT SHALL CONNECT A FIRE SPRINKLER SYSTEM TO LANDLORD'S SPRINKLER SYSTEM WITHIN THE DEMISED PREMISES UNSING APPROVED MEC1- IANICAL FITTINGS. TENANT SHALL PROVIDE AND INSTALL ALL BRANCH PIPING AND SPRINKLERS REQUIRED TO COMPLETE THE SPRINKLER SYSTEM WITHIN TENANT SPACE. TENAT'S SPRINKLER SYSTEM DESIGNS SHALL BE BASED UPON THE REQUIREMENTS OF THE STATE OF WASHINGTON, CITY OF TUKWILA FIRE DEPARTMENT. TENANT SHALL ENGAGE THE SERVES OF A LANDLORD PREFERRED FIRE SPRINKLER CONTRACTOR TO DESIGN, PERMIT AND INSTALL TENANT'S FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH THE BASE BUILDING DESIGN SPECIFICATIONS. SPRINKLER LAYOUT AND PIPE SIZING SHALL BE HYDRAUICALLY DESIGNRF ACCORDING TO ORDINARY l- IAZARD GROUP 2 AND THE LATEST REQUIREMENTS OF NFPA -13. ALL SPRINKLER HEADS IN THE FORWARD SELLING AREA ARE TO BE CONGEALED FOP OFF COVER TYPE. TENAT'S CONTRACTOR SHALL INSTALL AN INSPECTORS TEST CONNECTION, PIPED TO A FUNNEL DRAIN, (WITH WET TRAP), MOUNTED 3' -0" APP. INSTALL A 1" CORROSION RESISTANT SHUT -OFF VALVE. SHALL INSTALL A VANE TYPE WATERFLOW DETECTOR IN THE MAIN SPRINKLER LINE IMMEDIATELY AFTER CONNECTION NO. DESCRIPTION DATE 1. REVISED AS PER 04/04/8 LANDLORD AND CLIENT COMMENTS 2. REVISED AS PER 06/02/8 CLIENT COMMENTS DATE: 12/17/07 SCALE: AS NOTED GROSS AREA: 2,164 SQ. FT. SALES AREA: 1,272 SQ. FT. PROJECT # : 0712260 HVAC S''r-STEM IS TO BE NEW, SY MECHANICAL CONTRACTOR, WITI -I NEUJ DUCTWORK HVAC SYSTEM IS TO I5E NEW, BY LANDLORD'S MECHANICAL CONTRACTOR, DUCTWORK BY THIS CONTRACTOR HVAC 51 -STEM 15 EXISTING TO REMAIN, MECHANICAL CONTRACTOR TO fi ROVIDE NEW DUCTWORK I-IVAC SYSTEM 15 EXISTING TO REMAIN, MECHANICAL CONTRACTOR TO MAKE MODIFICATIONS TO EXISTING DUCTWORK DRAWN BY: Lady Foot Locker MECHANICAL PLAN TO LATHE LANDLORD'S MAIN, WHICH IS CONNECTED LANDLORD'S FIRE ALARM SYSTEM. �� _ � �� SCALE: 1/4 — 1 -0 1 1 CONICAL BELLMOUTH FITTINGS WITH MANUAL BALANCING DAMPER TO SE USED FOR ALL ROUND BRANCI -4 TAPS ABOVE ACCESSIBLE LAY -IN CEILINGS. CONICAL BELLMOUTH FITTINGS WITHOUT MANUAL BALANCING DAMPERS TO BE USED FOR ALL ROUND BRANCH TAPS ABOVE INACCESSIBLE DRYWALL CEILINGS WIT1 --I BALANCING REQUIRED WITHIN 2 FT. OF DIFFUSER WITH PLASTER FRAME. 2 ROUND RIGID SUPPLY AIR DUCTS SHALL BE EXTERNALLY INSULATED WITH 1" THICK, 13 LBS. DENSITY FOIL FACED FIBERGLASS INSULATION. 3 FLEX CONNECTIONS TO DIFFUSERS ARE INSULATED FLEX WITI-4 4 MAXIMUM LENGTH OF 5 FT. 4 MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ALL TRADES, LANDLORD REQUIREMENTS, CEILING HEIGHTS AND EXISTING STRUCTURAL CONDITIONS PRIOR TO FABRICATION OF ANY DUCTWORK OR ORDERING OF ANY EQUIPMENT. 5 MECHANICAL CONTRACTOR TO PROVIDE TENANT WITH AS -BUILT DRAWINGS, ALL EQUIPMENT SHOP DRAWINGS, INFORMATION ON THERMOSTATS, CONTROL WIRING DIAGRAMS AND OTHER PERTINENT INFORMATION AT COMPLETION OF PROJECT. C? MECHANICAL CONTRACTOR 15 TO PROVIDE AND INSTALL FIRE DAMPERS IN ANY EXISTING OR NEW DUCTWORK THAT PENETRATES A FIRE RATED PARTITION AS REQUIRED BY CODE- 1 NO FIBERGLASS OR FIBERBOARD DUCTWORK ALLOWED - 0 1 THE MECHANICAL CONTRACTOR SHALL FURNISH 8 GENERAL CONTRACTOR TO UNDER CUT DOOR, 1" FOR TI- ERMOSTATS COMPATIBLE WITH THE VAV BOXES USED. AIR PASSAGE WAY. 2 MECHANICAL CONTRACTOR TO PROVIDE SMOKE VERIFY ALL CONDITIONS IN THE FIELD BEFORE STARTING SYMBOL OL DESCRIPTION SYMBOL DESCRIPTION SUPPLY AIR DIFFUSER SHADING DENOTES BLANK -OFF DUCT MOUNTED DIFFUSER RETURN AIR GRILLE OR DUCT SUPPLY AIR DUCT 815E SIMILAR FOR RETURN AIR SUPPLY AIR DUCT DROP SIMILAR FOR RETURN AIR HIGH SIDE WALL LOW SIDE WALL MECHANICAL CONTRACTOR ELECTRICAL CONTRACTOR ROOT" MOUNTED EQUIPMENT 45 NOTED BROAN MODEL 6Sro COMBINATION LIGHT/ TOILET EXHAUST FAN THERMOSTAT (S- DENOTES SENSOR) TUNING VANES DUCT TRANSITIONS REVIOILAN fliki..t_ BRANCH DUCT SPIN -IN FITTING AND VOLUME DAMPER DUCT SMOKE DETECTORR CE VED JUN 0 9 2008 DETECTOR IN SUPPLY Al R OF VAV BOX. SMOKE WORK L. DETECTOR TO BE CONNECTED TO LANDLORDS SMOKE DETECTION SYSTEM. COORDINATE EXACT REQUIREMENTS WITH LANDLORDS ON SITE REPRESENTATIVE. 3 TOILET EXHAUST FAN (120V., 1 PH., 6>a 1-1Z) COMPLETE WITH INTEGRAL BACK DRAFT DAMPER AND ON -OFF SWITCH, UNIT SHALL BE FURNISHED BY TENANT (WITH LIGHTING PACKAGE). EXHAUST CAPACITY SHALL BE 15 CFM. EXTEND THRU THE ROOF AS REQUIRED. 4 OPENINGS IN DEMISING WA LL PER LANDLORD CRITERIA. COORDINATE ALL RETURN AIR OPENINGS WITH LANDLORD'S ON SITE REPRESENATIVE 5 MECHANICAL CONTRACTOR TO PROVIDE VAV -1 AND 2, PER SCHEDULE ON SHEET M2.0. NEW CONNECTION TO EXISTING LANDLORD MEDIUM PRESSURE DUCT TO BE DONE IN ACCORDANCE WITH LANDLORD CRITERIA- FIELD VERIFY EXACT LOCATION PRIOR T BID- �I GENERAL CONTRACTOR SHALL MAINTAIN A MINIMUM OF 6" UNOBSTRUCTED CLEARANCE HEIGHT IN RETURN AIR PLENUM ABOVE CEILING ALLOWING FO1z AIRFLOW BACK TO LANDLORD AIR CONDITIONING SYSTEM. PROJECT TITLE SOUTHCENTER MALL 304 SOUTHCENTER PKWY TUKWILA, WA , 98188 SPACE #1560 STORE No. 46171 \ t /' 1 / i Ot fi_1 JJ JJ IA t tY SHEET TITLE MECHANICAL PLAN • SHEET NO. M 1 • 0 HSW LSW MC. EC. s MECHANICAL GENERAL NOTES 0 MECHANICAL CODED NOTES 4 SYMBOL SCHEDULE PENIS UWE� FILE COPY . 1: oo/� f'f'�OLIi)T -'e /yore: ` - Mer,,9s /co/Lola- NOT 6 2 Ga bf pg,ov1Df c-4,-/K1111/66 P • SOUND SYST FOOT LOCKER INC. STORE PLANNING DEPT 112 WEST 34TH STREET NEW YORK, NY 10120 PHONE 4 FAX 0 COMPUTER Q 1 -' DATA � -1 �® NEW EXIT ,4LGOVE4$ L7G O 10 NEW ELECTRICAL PANELS _ A -15 ■ - CONFIRM LOCATION A -2 < ~ I I ARCHITECT: JAMES M. HAMILL, A.I.A. 580 DECKER DRIVE, SUITE 170 I RVI N G, TEXAS 75062 PHONE: (972) 714-0420 c NEW TOILET • w�ii�o�L■ -r.rrrrorai rrrrrrrn '� ���; r� V� -1 r' A -29 �► 1 i A -2 MANAGER'S �:r ��40 L_ - -- _I S S` _� S S;_ - - (TYP ' ice■,. _�_ _r��� • II CTYP) / I S S� 1 S G � ` - - I � _ 5 II r 1 VAV -2 I E1rd I � %�� ,4 -221 S _ - PROJECT CO- ORDINATOR: P A U L P A R T N E R S H I P - TORONTO CALGARY • VANCOUVER 2660 Sherwood Heights Dr. Suite 200, Oakville, Ontario, L6J 7Y8 1-888-855-5061 fax (905)337-1986 --- - ---- -- _- ®2 i'i EM � \ �I' 1 �--- �----- �— �- �NWFITTINGI �� ��MN1 + + + ROOM AND I BDAfiR1r L - 1 — _ I I — — CCESSOIS 1 0 i 1 NEW O A ■ 1 SAGKWRAP I H LI If-7 Y Ir—T77T7 11► AND GASNWRAP 1 e- STOREFRONT II 1 AND GLASS DOORS 1 1 _ 7T71— T7IlT71— T-11 -7I — _T 7 I I I I I I I I I I I (TYP,T II 1 1101 11 11 1 I 11 1 11 11 I 1 I H 11 II I I � TT � A-1 1 1 1 1 1 1 II I o 4� HE —H HI— + —I I— — —I I— — H 11 1 H 11 1 1 11 I 11 1 11 1 11 1 I I 11 1 11 1 11 1 1 - I— H— —H I H —-- I— H T + —I I I / _ I I 11 11 1 H 1 11 I 1 H 1 11 1 11 I H 11 I 1 H I H I 11 I II 1 I �TYIl I I 1 1 I H 1 1 1 1 11 1 1� 1 1 11 1 1 ��� / ,/ \/\ I ► �� 0 ENGINEER ) J +r► 1 II 1 H 1 11 I I 1 1 H I 11 1 11 I 11 11 1 I I 1 11 1 11 1LL_LJ_JLL _IL J_J L_1__1 ILJL LJLLJL__1 LJ JL_LJ I - / - ----- 7- - - - 7- 1 F — 7- ----- T. - - - --I I I-- --- - - - --1 — 1 1 (TYP) O (TYP) 12 _ LLD FOR cape e 14EC V% \ 2�, 9 REVISIONS changes shall be made to the scope of wont without p pproval of ®VV s���°° prior a Lt- Tukwila Building @t- ild Division- BU Revisions will require a new plan submittal may include additional plan review fees. Emphasis On Excellence M- Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 TEL: 614.818.2323 FAX: 614.818.2337 OR 18 20 ;-,.,-,,-.‘No . c: ,;v ($V (%\ g - ; - p J r p e, -- J . rbti'19 Q�� - i 1. b7 11 % / 09 and COPY :,- ter.. • REVISIONS NOTE: IN HANDICAPPED AREAS, THE RECEPTACLES AND TELEPHONE OUTLETS SHALL BE MOUNTED SEPARATE PERMIT REQUIRED FOR 11 Mil ❑ Electrical lif Plumbing Vf Gas Piping City of Tukwila LglrilLD1NG DIVISION plan review approval Is subject to eirors ; missions, Approval of caftucthrin documents nail the violation ofwloldapNdcodeolr ordnance. Receipt of approved Reid Copy and melon is - ,_,,s---,-- . -.:,: _,. • a, o„ y l O►' y� �� NO. DESCRIPTION DATE Date: 0 — °e City Tidcwila AT 24" AF.F.± THE TOGGLE SWITCHES, THERMOSTATS AND MANUAL MOTOR STARTERS SHALL BE MOUNTED AT 42" AF_F. BUILDING DIVISION POWER PLAN ALL SYMBOLS DO NOT NECESSARILY APPLY SCALE: 1/4" = 1' -0" DATE: 12/17/07 FIELD VERIFY ALL CONDITIONS SYMBOL DESCRIPTION MOUNTING 1-1GT. TO CENTERLINE UNLESS OTHERWISE NOTED SYMBOL DESCRIPTION MOUNTING HGT. TO CENTERLINE UNLESS OTHERWISE NOTED SYMBOL DESCRIPTION MOUNTING HOT. TO CENTERLINE UNLESS OTHERWISE NOTED SCALE: AS NOTED DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL �/ISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHAL1� INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS_ THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL ESE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. © WIRED JUNCTION BOX SEE DRAWINGS -+ MANUAL MOTOR STARTING SWITCH W/ PILOT LIGHT 48" AFF. (TYP) F FIRE ALARM BREAK STATION 45" AFF. (TYP) GROSS AREA: 2,164 SQ. FT. DUPLEX RECEPTACLE, 3 WIRE GRD. TYPE, 20A 15" AFF. (TYP) I� TELEPHONE OUTLET IS" AFF. (TYP) [4 FIRE ALARM AUDIO /VISUAL SIGNAL DEVICE 80" A.F. (TYP) SALES AREA: 1 ,272 SQ. FT. u1P DUPLEX RECEPTACLE, WEATHERPROOF ,20A 18" AFF. (TYP) 4 2 TELEPHONE OUTLET - DUPLEX 1a" AFF. (TYP) ® SMOKE DETECTOR AT FINISH CEILING PROJECT # : 0712260 rFl GROUND FAULT PROTECTED DUPLEX RECEPTACLE, 204 IS A.F.F. (TYP) 11 DATA OUTLET - CATEGORY 5 15" AFF. (TYP) s FIRE ALARM VISUAL SIGNAL DEVICE 80" AFF. (TYP) DRAWN BY: ,;. QUADRAPI_EX WALL RECEPTACLE, 20A 18" AFF. (TYP) l<2 DATA OUTLET - DUPLEX CATEGORY 5 15" A.F.F. (TYP) L PANIC EXIT DOOR LOCK GF_I. W /LIGHT 4 SWITCH AS REQUIRED SAFETY SWITCH AS REQUIRED .�. �._, 15" VGA MONITOR Lady Foot Locker 1 H • PUSHBUTTON STATION 48" AFF. (TYP) ® MAGNETIC MOTOR STARTER AS REQUIRED ® MINI DOME CAMERA a LOW VOLTAGE BUZZER TRANSFORMER AS REQUIRED ®-' COMBINATION STARTER/SAFETY SWITCH Ae REQUIRED 0 APV MONITOR DOOR BUZZER 54" AFF. (TYP) ® MOTOR OUTLET - 1 PHASE AS REQUIRED � TOGGLE SWITCH - SINGLE, 3 -WAY 4 4 -WAY 48" AFF. (TYP) 0 MOTOR OUTLET - 3 PHASE AS REQUIRED / I ELECTRICAL SYMBOLS 1. REFER TO MECHANICAL PLAN FOR LOCATION OF MECHANICAL EQUIPMENT. FIELD VERIFY EXACT LOCATIONS. 2. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL AT PANEL 'A' TYPED PANEL DIRECTORY WITI --1 ALL CIRCUITS ACCURATELY DESCRIBED PRIOR TO STORE OPENING_ 3. ALL RECEPTACLES AND SWITCH PLATES IN SALES AND NON -SALES AREAS TO MATCH WALL OR CEILING FINISH UNLESS DIRECTED OTHERWISE. TYPICAL MOUNTING HEIGHT IS IS AFF. EXCEPT AT COUNTERS OR IF DIRECTED OTHERWISE 4. ALL CONDUITS SHALL ISE CONCEALED IN WALLS AND OUTLET BOXES SHALL BE FLUSH WITH FINISHED WALL UNLESS OTHERWISE NOTED. 5. ALL WORK 5HALL BE IN STRICT ACCORDANCE WITH NATIONAL ELECTRIC CODE AND ALL LOCAL CODES AND ORDINANCES. 0 20AMP, 120V_, ISOLATED GROUND /DEDICATED CIRCUIT RECEPTACLE (HUBBELL 0IG -5362) FOR CASH REGISTERS. DO NOT INSTALL WITI -1 ANY OTHER CIRCUITS. LOCATE RECEPTACLES AT CASH /WRAP COUNTER x AS DIRECTED BY OWNERIARGHITEGT. RUN 2 12 THHN AND 2 X12 ISOLATED GRD_ PER CIRCUIT IN A COMMON 1" CONDUIT IN FLOOR SLAB TO WALL, UP WALL AND TO PANEL. ® NOT USED. ® NOT USED. ® SEE DETAIL C/E1.1 FOR TELEPHONE REQUIREMENTS. ® 20AMP, 120V., DUPLEX RECEPTACLE ,AT CASH WRAP COUNTER FOR UTILITY POWER- LOCATE RECEPTACLES AT CASH WRAP COUNTER AS DIRECTED BT OWNER. RUN 2 012 THW AND 1 12 GRP IN 1" CONDUIT IN FLOOR SLAB TO WALL, RUN UP WALL TO JUNCTION BOX AND CONNECT TO CIRCUIT INDICATED. REFER TO CABLE BLOCK DIAGRAM ON SHEET E4.0. 20AMP, 120V., ISOLATED GROUND /DEDICATED CIRCUIT, RECEPTACLE (HUBBELL SIG -5362) MOUNTED AT IS" AFF. DO NOT INSTALL WITH ANY OTHER CIRCUITS RUN 2 12 THWN AND 2 12 ISOLATED GRD- IN SINGLE 3/4" CONDUIT SACK TO PANEL FOR COMPUTER TERMINAL. ® SEE DETAIL "C" ON SHEET EL1 FOR TELEPHONE RISER DIAGRAM ® 3/4" CONDUIT FOR CASH REGISTER WIRELESS ACCESS POINT. RUN 3/4" CONDUIT FROM CASH WRAP COUNTER TO DATA OUTLET /JUNCTION BOX AT MANAGER'S DESK COORDINATE REQUIREMENTS WITH OWNER/ARCHITECT. REFER TO CABLE BLOCK DIAGRAM "G" ON SHEET E4.0. ® NOT USED. POWER EQUIPMENT: REFER TO POWER RISER ON SHEET E3.0 FOR MORE. 10 INFORMATION ® RECEPTACLES AND COVERPLATES WITH AN "SF" DESIGNATION SHALL BE FLUSH MOUNTED IN CEILING AT STOREFRONT, PARALLEL TO STOREFRONT GLASS. CIRCUIT TO PANEL AS INDICATED. (NEC AT 210 -62) 12 MOUNT SALES AREA DUPLEX RECEPTACLES AND COVERPLATES AT 18" AFF.. WHERE RECEPTACLES ARE LOCATED BEHIND WALL PANELS, MOUNT HORIZONTALLY AT 5" AFF.. CIRCUIT TO PANEL AS INDICATED. ® NOT USED. 14 NOT USED. 15 SEE DETAIL F/ E1.1 FOR REAR DOOR BUZZER SYSTEM 16 o SEE DETAIL B/E 1.1 FOR PANIC EXIT DEVICE. li 1/2" EMPTY CONDUIT WITH PULL STRING FROM ANU -1 TO THERMOSTAT. REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION AND DETAILS "H" ON SHEET E1_l. IS REFER TO HVAG CONNECTION SCHEDULE FOR WIRING, CONDUIT, AND CIRCUIT REQUIREMENTS. 19 PROVIDE JUNCTION BOX, TOGGLE DISCONNECT SWITCH IN CONCEALED LOCATION AND FINAL CONNECTION FOR 120 VOLT SIGN. SIGN FURNI5I -4ED BY TENANT. COORDINATE EXACT LOCATIONS WITH TENANT'S CONSTRUCTION MANAGER- 0 WIRE THROUGH TIME CLOCK REFER TO SHEET E30 FOR MORE INFORMATION_ 21 MOUNT DUPLEX RECEPTACLES HORIZONTALLY BELOW COUNTER. COORDINATE EXACT LOCATION WITH CABINET MANUFACTURER 2 RECEPTACLES AND CDVERPLATES IN NON -SALES AREA SHALL BE MOUNTED AT IS" AFF. UNLESS NOTED OTHERWISE. CIRCUIT TO PANEL AS INDICATED. 23 PROVIDE CONNECTION TO ELECTRIC WATER HEATER PER NEC. o 24 DEDICATED RECEPTACLE FOR SOUND SYSTEM MOUNTED ON SHELF. VERIFY EXACT REQUIREMENTS WITH SOUND SYSTEM COMPANY "GROWS NEST" AT (425) 643 -5033. THE ELECTRICAL CONTRACTOR SHALL INCLUDE IN HIS BID THE COST FORA COMPLETE 25 OPERATIONAL FIRE ALARM SYSTEM. THIS SYSTEM SHALL INCLUDE, BUT NOT BE LIMITED TD, RELOCATING EXISTING DEVICES, REPLACING DAMAGED DEVICES, AND ADDING ADDITIONAL DEVICES AS REQUIRED TO MEET CODE REQUIREMENTS. A LICENSED FIRE ALARM CONTRACTOR SHALL PREPARE AND SUBMIT, TO TINE LANDLORD FOR APPROVAL, A COMPLETE FIRE ALARM SYSTEM DRAWING AND MATERIALS LIST, PRIOR TO COMMENCING ANY WORK FINAL CONNECTIONS TO THE LANDLORD'S BASE SYSTEM SHALL BE BY THE LANDLORD'S FIRE ALARM CONTRACTOR AT TENANT'S EXPENSE. 26 LANDLORD'S JUNCTION SOX WITH 1" CONDUIT ,TO TIE INTO MALL'S CENTRAL FIRE ALARM SYSTEM. SEE FIRE ALARM SYSTEM . VERIFY LOCATION AND EXACT REQUIREMENTS WITH THE LANDLORD. APPROVEc pl "��^ n n rnrr+,r,,, T, ir, ��,� P•.,r ^„ F,"' ` ',, ,�A. +71,- ,� _. ,,U HOR MODIFIED ORALTE UIL VIIITHOUT ALtTHDR1ZAT10n1 FROM TI1E BUilD,'N(3 DF"Iw:AL, ALL WORK SHALL BE [3CNE IN ACCORDANCl WITH THE APPROVEp p IS x' 12 c�T O FIE D SPECTln�p�3 S RECEIVED CITY OF TUKWILA Public Works, Building Division JAN 0 8 ZOO PERMIT NUMBER 0 PERMIT CENTER 0 8�/ 0 5 Approo,� - fj D - PROJECT TITLE SOUTHCENTER MALL 633 SOUTHCENTER Pf\ V V Y '� /�, /� q /� TU r\ V V I L/�, V V /`1, 98135 SPACE #1560 STORE NO. 46171 -°��� TAG 1 I 1 1 „ 1 1 1 TEL. CONDUIT IV o CONDUIT DATA ISOLATED GROUND CIRCUIT CONDUIT SHEET TITLE ELECTRICAL POWER PLAf�I UTILITY POWER CONDUIT iii0f..._ 02:6 1 r 0 - 1 ' GENERAL POWER NOTES � - -`. 14 ; POWER CODED NOTES TYP. CONDUIT STUB -UP @ CASHWRAP SHEET NO. FILE COPY J -BOX FOR DESK LIGHTING. COORDINATE EXACT LOCATION WITH DESK SUPPLIER 1CL -4 '' S' -0" AFF. CL -1 e 1I'-0" AFF. I —1 CL -1 e 11' -0" AFF. CL-1 e 11' -6" AFF. I A -3 NOTE: 2006 IBC — Sec. 1006 Provide an average of one foot - candle illumination at the .&.? floor along the entire egress pathway and exit discharge LIGHT FIXTURE SCHEDULE AREA TYPE SALES SYMBOL MANUFACTURER DESCRIPTION LAMP TYPE AREA SYMBOL MANUFACTURER DESCRIPTION F1 SIMKAR CH2132B11 -UNV S' - 2 LITE TANDEM FLUORESCENT STRIP P1-12466-1 32W TS FLUORESCENT LAMP SW 0 JBL SJ -I. SUS WOOFER l ® 4 F1 -4 TRACK LIGHTS TRACK LIGHTS II� a SIMKAR CI-1132B11 -UNV 4' - 1 LITE TANDEM FLUORESCENT STRIP 32W T r°7 32W TS FLUORESCENT LAMP SP '� JBL SJ -2: SPEAKER l l F2 MERCURY 54E340- BIAX -9 -ELB 2'x2' PARABOLIC ELECTRONIC BALLAST RECESSED FIXTURE F40 XSPX35 40W BIAX LAMP • � • MONITOR mom ... F2 /EM MERCURY S4E340- BIAX -9- ELEVEN NIGHT/EMERGENCY LIGHT 2'x2' PARABOLIC ELECTRONIC BALLAST RECESSED FIXTURE F40BX5PX35 4011 BIAX LAMP El ® HIGHLIGHT BP- PLED -�a -R LED UNIVERSAL EXIT SfGN !•■em MEM RD 0 JUNO CVS1263242T WHITE TRIM RING S20C -W1-1 CF42DTES35 42 WATT COMPACT FLUOR A4 e CON -TECH CTL503S -P TR4CKI -1E4D IN WHITE PHILIPS GDM -i25W /PAR 38/FL /3K E2 HIGHLIGHT MOUNTED AT 12' - HL -°0 -DL SURFACE MOUNTED EMERGENCY LIGHT - COLOR WHITE 6' AFF OR MAX ALLOWABLE BY CODE TF2 CON-TECH CTL1540 -P B[AX TRACK HEAD W/ CLEAR LOUVER 40W F40BXSPX35 BIAX LAMP SD @ SMOKE DETECTOR SUPPLIED AND INSTALLED BY TENANT'S' G.G- I�----1 44 -N CO AMERILUX IMZ T6 M1-1 TRACKHEAD: SATIN CROME FINISH. PHILIPS CDM35TC /S30 = — —_ — — BANNER TRACK SYSTEM TF CON -TECH l*L.TSP CS' LTH) CHANNEL 1_T6P (6' LTH) SPRING LOADED ATTACHMENT TRACK sl_T4P (4' LTH) MOUNT DIRECTLY TO LAY -IN CEILING 1LT2P (2' LTH) EF NUTONE 163RLN RECESSED 50 CFM FAN /LIGHT UNIT WFTI -1 (1) 100 W BULB r EX = EXISTING LIGHT TO REMAIN - VERIFY EXISTING QUANTITIES RE = EXISTING LIGHT TO SE RELOCATED - VERIFY EXISTING QUANTITIES 2 LIGHT FIXTURE SCHEDULE NL = DENOTES NIGHT/EMERGENCY LIGHT CODE COMPLii-ACE 'NFPfk 70 - NEC 0 IO$ FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BEDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS OF ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL DIVISIONS OF WORK IT IS THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 2. LIGHTING SHALL BE CIRCUITED EXACTLY AS SHOWN ON PLANS. 3. GENERAL CONTRACTOR TO INSTALL TENANT FURNISHED CRUSH GUARD SAFETY SLEEVES TO ALL STOCKROOM FLCURESCENT LIGHTING. LIGHTING GENERAL NOTES 4. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION AND QUANTITY OF LIGHTING FIXTURES. s_ EMERGENCY AND EXIT LIGHTS SHALL BE INSTALLED AND CIRCUITED PER TI-4E LATEST NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES. ALL EMERGENCY AND EXIT FIXTURES SHALL BE DUAL VOLTAGE (120/271 VOLT INPUT) WITH BATTERY BACKUP. e2. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. O TENANT E.C. TO FURNISH AND INSTALL CONDUIT AND PULL WIRE TO ALL A/V LOCATIONS AS REQUIRED BY A/V VENDOR. CONFIRM REQUIREMENTS AND LOCATIONS WITH OWNER PRIOR TO BID. SEE DETAIL K ON SHEET E1.1. /7,\ WIRE THROUGH A 6 POLE CONTACTOR CONTROLLED BY A TIME SWITCH. CONTACTOR AND TIME SWITCH SHALL BE AS SPECIFIED IN SPECIFICATIONS AND MOUNTED ADJACENT TO LIGHTING PANEL. REFER TO SHEET E3.0 AND SPECIFICATIONS FOR MORE INFORMATION. /7A HOMERUN THROUGH A 2 POLE CONTACTOR CONTROLLED BY SWITCH "a ". CONTACTOR SHALL \-/ BE AS SPECIFIED IN SPECIFICATIONS AND MOUNTED ADJACENT TO LIGHTING PANEL. SEE MASTER LIGHTING SWITCH BANK DETAIL ON THIS SHEET AND "POWER RISER" ON SHEET E3.0. HOMERUN THROUGH A 2 POLE CONTACTOR CONTROLLED BY SWITCH "b ". CONTACTOR SHALL BE AS SPECIFIED IN SPECIFICATIONS AND MOUNTED ADJACENT TO LIGHTING PANEL. SEE MASTER LIGHTING SWITCH BANK DETAIL ON THIS SHEET AND "POWER RISER" ON SHEET E3.0. /7.\ HOMERUN THROUGH A 4 POLE CONTACTOR CONTROLLED BY SWITCH "c ". CONTACTOR SHALL BE AS SPECIFIED IN SPECIFICATIONS AND MOUNTED ADJACENT TO LIGHTING PANEL. SEE MASTER LIGHTING SWITCH BANK DETAIL ON THIS SHEET AND "POWER RISER" ON SHEET E3.0. HOMERUN THROUGH A 4 POLE CONTACTOR CONTROLLED BY SWITCH "d ". CONTACTOR SHALL BE AS SPECIFIED IN SPECIFICATIONS AND MOUNTED ADJACENT TO LIGHTING PANEL. SEE MASTER LIGHTING SWITCH BANK DETAIL ON THIS SHEET AND "POWER RISER" ON SHEET E3.0. OCONNECT EXIT, EMERGENCY, AND NIGHT LIGHTING FIXTURES TO NL /EM /EX CIRCUIT IN ±/ NON – SALESAREA #A -28, IN SALES AREA #A- 26(TYPICAL). PROVIDE SCREW TYPE LO'S AT THE BREAKER. CIRCUIT TO UNIT EQUIPMENT EMERGENCY LIGHTING MUST COMPLY WITH N.E.C. ARTICLE 700 -12E. / , MASTER LIGHTING SWITCH BANK TO BE LOCATED AT REAR DOOR TO SALES AREA. SEE �/ DETAIL '5' ON THIS SHEET. LIGHTING CODED NOTES REFLECTED CEILING PLAN NOTES EMERGENCY LIGHTS TO BE INSTALLED ON SEPARATE CIRCUIT. SMOKE /HEAT DETECTOR SPACING SHALL COMPLY WITH THE REQUIREMENT OF NFPA 72 -E. THE INSTALLING CONTRACTOR SHALL SUBMIT A CEILING FLAN SHOWING THE LOCATION OF THE DETECTORS TO THE FIRE MARSHALL FOR APPROVAL BEFORE STARTING WORK, IF REQUIRED BY LOCAL AUTHORITIES. REFER TO FINISH SCHEDULE SPEC 4 INTERIOR ELEVATIONS FOR FINISHING 4 PAINTING REQUIREMENTS. THE POSITION OF THE TRACK IS TYPICALLY SET OUT FROM PERIMETER WALL AS INDICATED. UPON COMPLETION OF JOB, CONTRACTOR SHALL BALANCE THE AIR AND SUBMIT CERTIFIED COPY OF AIR BALANCE REPORT TO THE TENANTS PROJECT MANAGER G.C. TO ADVISE TENANT PROJECT MANAGER OF MAX CLEAR HEIGHT IN STOCK ROOM PRIOR TO PROJECT COMMENCING. THIS IS TO ALLOW THE HEIGHT OF THE STOCK ROOM SHELVING TO BE MAXIMIZED GC. SHALL FIELD EXAMINE THE CONDITION OF EXISTING TENANT DEMISING PARTITIONS 4 EXTERIOR GLAZING WALLS AND PROVIDE FULL HEIGHT 4 FINISHED PARTITION TO UNDERSIDE OF ROOF DECK AS REQUIRED. ALL EXPOSED PARTITIONS AT SALES AREA MUST BE TAPED, 5PACKLED AND PAINTED IN THEIR ENTIRETY. FIRE SPRINKLER SYSTEM: EXISTING SPACE FIRE SPRINKLER SYSTEM TO BE MODIFIED PER NEW TENANT SPACE DRAWINGS AS REQUIRED BY NFPA STANDARDS AND LOCAL CODES. ALL ARI=AS TO BE ORDINARY HAZARD GROUP If OCCUPANCY WITH FIRE SPRINKLER FABRICATION DRAWINGS TO BE SUBMITTED BY TENANT FIRE PROTECTION CONTRACTOR TO BUILDING DEPARTMENT BEFORE WORK COMMENCES. ALL SPRINKLER HEADS WILL BE SEMI - RECESSED CHROME TYPE CENTERED IN 2X2 CEILING GRID. SPRINKLER HEADS - NOTE: SYMETRICAL PATTERN TO ALIGN W/ CEILING ELEMENTS. REFLECTED CEILING PLAN NOTES O SALES AREA SALES AREA SALES AREA GALES AREA ® O ® ® FLUOR. LIGHTS FLUOR- LIGHTS TRACK LIGHTS TRACK LIGHTS II� a 11b 11 IIGII nor RECEIVED CITY OF TUKWILA JAN O87.008 PEHMIT CENTER MASTER LIGHTING SWITCH BANK FOOT LOCKER, INC. STORE PLANNING DEPT 112 WEST 34TH STREET NEW YORK, NY 10120 ARCHITECT: JAMES M. HAMILL, A.I.A. 580 DECKER DRIVE, SUITE 170 IRVING, TEXAS 75062 PHONE: (972) 714 -0420 PROJECT CO- ORDINATOR: P A U L P A R T N E R S H I P T O R O N T O • CALGARY • V A N C O U V E R 2660 Sherwood Heights Dr. Suite 200, Oakville, Ontario, 1,6,1 7Y8 1 -888- 855 -5061 fax (905)337 -1986 ENGINEER Emphasis On Excellence M- Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 TEL: 614.818.2323 FAX: 614.818.2337 REVISIONS NO. DESCRIPTION DATE DATE: SCALE: GROSS AREA: SALES AREA: PROJECT # DRAWN BY: 12/17/07 AS NOTED 2,164 SQ. FT. 1,272 SQ. FT. 0712260 Lady Foot Locker PROJECT TITLE SOUTHCENTER MALL 633 SOUTHCENTER PKWY TUKWILA, WA, 98188 SPACE #1560 STORE No. 46171 SHEET TITLE ELECTRICAL LIGHTING PLAN SHEET NO. E2.O Panel Wiring Schedule (3- Phase) Panel Wiring Schedule (3- Phase) Panelboard "A" Voltage 208Y/120 Phase 3 Options /Notes Panelboard "H" Voltage 480Y /277 Phase 3 Options /Notes FOOT LOCKER, INC. STORE PLANNING DEPT 112 WEST 34TH STREET NEW YORK, NY 10120 Panel Type NQOD OCPD 150A M.C.B. Wire 4 Panel Type NQOD OCPD 100A M.C.B. Wire 4 ARCHITECT: JAMES M. HAMILL, A.I.A. 58D DECKER DRIVE, / SUITE 170 I RVI N G, TEXAS 75062 PHONE: (972) 714-0420 - NEMA Type 1 Mounting SURFACE Buss 225A AIC Rating 10,000 NEMA Type 1 Mounting SURFACE Buss 100A NC Rating 18,000 ELECTRIC LOAD SUMMARY (TRANSFORMER) 208Y/120V LOADS Ckt. No. 1 Zone Load Description STORE FRONT TRACK Brkr. Size * Brkr. Opts. - LO N.E.C. kVA ** 0.312 Phase A N.E.C. kVA ** 1.500 Brkr. Opts. - - Brkr. Size * Load Description - --- -.__ SALES TRACK Zone Ckt. Ckt. No. No. Zone Load Description Brkr. Size * Brkr. Opts. N.E.C. kVA u Phase N.E.C. kVA ** Brie. Opts. Brkr. Size * Load Description Zone Ckt. No, DESCRIPTION N.E.C. CONNECTED kVA NEC DEMAND NOTES N.EC. DEMAND FACTOR N.E.C. DEMAND kVA 2 1 VAV -1 20/3 3.000 A 7.772 TRANSFORMER 2 3 STORE FRONT LTS LO 0.675 B t200 SALES TRACK 4 3 HACR 3.000 B 7.705 70/3 4 LIGHTING (CONTINUOUS) _ -__ -- TRACK LIGHT DEMAND ALLOWANCE 13.033 [1] [2] 1.25 - 16.291 0.000 5 NON -SALES LIGHTS 0/40 C 1.20D SALES TRACK 6 5 3.870 C 6.596 6 7 SIGN 1.200 A 1.500 SALES TRACK 8 7 VAV -1 1.667 A 0.000 8 SHOW WINDOW DEMAND ALLOWANCE - 0.000 [3] [4 - 2.000 0.000 9 S.F. RECEPTACLES 0.360 B 1.350 SALES TRACK 10 9 20/3 HACR 1.667 B 0.000 10 _ KIT APPLIANCE 1.00 11 N.S. RECEPT. 0.900 C 0.636 SALES LTS 12 11 2.367 C 0.000 12 RECEPTACLES MOTORS 4.340 0.000 [5] [6] - - 4.340 0.000 13 SALES RECEPT. 0.720 A 0.720 SALES LTS 14 13 0.000 A 0.000 14 15 TELEPHONE BOARD 0.100 B 2.300 30/2 WATER HEATER 16 15 0.000 B 0.000 16 FIXED Fl FCTRIC SPACE HEATING 0.000 [6],[7] - 0.000 17 PANIC /BUZZER. 0.100 C 2.300 18 17 0.000 C 0.000 18 AIR CONDITIONING SYSTEM 0.000 [61[7] - 0.000 19 CASH REGISTER 0.360 A 0.100 LO FIRE ALARM PNL 20 ELECTRIC WATER HEATER 4.600 [B] 1.0 5.750 21 23 25 CASH REGISTER CASH REGISTER 0.360 0.360 0.360 B 0 0.000 0.000 Lo SPARE SPARE EM /NL /EX LTS 22 Notes Breaker Options: MISCELLANEOUS 0.100 - 1.0 0.100 24 * All circuit breakers to be 20 -Amp, 1 -Pole unless otherwise noted. AS Powerlink AS Breaker 26 ** All Phases to be balanced to within 10% using Actual Load Totals. LO Handle lock -on device 22.073 28.481 - CASH REGISTER A 1.000 N.E.C. OEM. KVA X 1000 = MINIMUM FEEDER AMPERAGE PROJECT CO-ORDINATOR: KPAUL P A R T N E R S H I P TORONTO • CALGARY • VANCOUVER 2660 Sherwood Heights Dr. Suite 200, Oakville, Ontario, L6J 7Y8 1- 888 -$55 -5061 fax (905)337 -1986 27 29 SOUND SYSTEM MANAGER'S COMPUTER -- - 0.360 0 0 1.000 0.000 LO EM NL EX LTS / /- 28 N.E.C. Connected Totals: Ph.A 12.439 kVA ST Shunt Trip Type 30 N.E.C. Connected Totals: Ph.B 12.372 kVA AUX Auxiliary Contacts SYS. VOLTAGE X 1.732 28.481 X 1000 W 79.1 AMPS 208 X 1.732 0.360 SPARE 31 33 SPARE SPARE 0.000 0.000 A B 0.000 0.000 SPARE SPARE 32 N.E.C. Connected Totals: Ph.0 12.833 kVA PA Handle Padlock Attachment 34 Total 37.644 kVA GEC! Ground Fault Circuit Interrupter 35 SPARE 0.000 C O.Q00 SPARE E Existing Circuit to remain HACR Heating, A/C & Refrigeration 36 g> 9 ELECTRIC LOAD SUMMARY 480Y/277V SYSIEM 37 SPARE 0.000 A 0.000 SPARE 38 IG Isolated Ground Circuit Connected Load: 45.3 amps SF Subfeed 39 SPARE 0.000 B 0.000 SPARE 40 NEC 2005 Demand Feeder Load: 53.0 amps AFCI Arc Fault Circuit Interrupter DESCRIPTION N.EC. CONNECTED kVA NEC DEMAND NOTES N.E.C. DEMAND FACTOR N.E.C. DEMAND kVA 41 SPARE 0.000 C 0.000 SPARE 42 Notes Breaker Options: LIGHTING (CONTINUOUS) TRACK LK iT DEMAND ALLOWANCE 13.033 - [1] [2] 1.25 - 16.291 0.000 * All circuit breakers to be 20 -Amp, 1 --Pole unless otherwise noted. AS Powerlink AS Breaker ** All Phases to be balanced to within 10% using Actual Load Totals. LO Handle lock -on device N.E.C. Connected Totals: Ph.A 7.772 kVA ST Shunt Trip Type N.E,C. Connected Totals: Ph.B 7.705 kVA AUX Auxiliary Contacts N.E.C. Connected Totals: Ph.0 6.596 kVA PA Handle Padlock Attachment SHOW WINDOW DEMAND ALLOWANCE - [3] - 2.000 KR APPLIANCE 0.000 [4 1.00 _ - 0.000 RECEPTACLES 4.340 [5] - 4.340 MOTORS 0.000 [6] - 0.000 Total 22.073 kVA GFCI Ground Fault Circuit Interrupter E Existing Circuit to remain HACR Heating, A C & Refrigeration / 9 10 Isolated Ground Circuit Connected Load: 61.3 amps SF Subfeed NEC 2005 Demand Feeder Load: 79.1 omPs AFCI Arc Fault Circuit Interrupter FIXED ELECTRIC SPACE HEATING 15.571 [fi],[7] - 15.571 AIR CONDmONING SYSTEM 0.000 [61[7] 0.000 ELECTRIC WATER HEATER 4.600 [8] 1.0 5.750 ENGINEER MISCELLANEOUS 0.100 - 1.0 0.100 TOTAL 37.644 TOTAL 44.052 N.E.C. DEM. KVA X 1000 = MINIMUM FEEDER AMPERAGE SYS. VOLTAGE X 1.732 44.052 X 1000 = 53.0 AMPS _ 480 X 1.732 Emphasis On Excellence M- Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 TEL: 614.818.2323 FAX: 614.818.2337 LOAD SUMMARY NOTES: [1] POWER FACTOR IS ALREADY INCLUDED IN LIGHTING LOAD. [2] 150VA /2Fr OF LINE VOLTAGE TRACK -I- SUM LOW VOLTAGE XFRMS - CONNECTED LOAD [3] 200VA /LF - ACTUAL CONNECTED LOAD 4 KIT APPLIANCE DEMAND FACTOR PER NEC 220-20 [51 0.0 < 10KW = 100 %, REMAINING - 50% t6 125% OF THE LARGEST MOTOR OR COMPRESSOR IN SYSTEM APPLIED ON ONE UNIT. [1 USE GREATER VALUE OF THESE TWO CATEGORIES [s] 125% DEMAND FACTOR FOR TANK 1YPE, 100% FOR INSTANT HOT HVAC CONNECTION SCHEDULE EQUIP. NAME VOLTAGE FLA /HP /KW WIRE CONDUIT DISCONNECT CIRCUIT VAV -I 400V 30 NEW SKW NEAT NEW 3012TI -1WN 4 10I2GRD NEW 3/4" NEW 30A NON -FUG. DISC. SW. 14-1/3/5 ����'.- �° e�A.�` 10. �� t �f1- 0 ,° a� TO CIRCUITS INDICATED ON A L DEC 1 8 2001 oo;� �jY of vvAls, ..4,c,-1 { e a... C Z 1�'l'4-W 386 '4- _�. O ; _ >r��;_;w:_;. a, , VAV -2 4S0V 30 NEW 'KW NEAT 3 12THWN 4 1 12CzRD NEW 3/4" 30A NON -ELLS. DISC. Sw. H- yen • NOTE: VERIFY EXACT OVER CURRENT PROTECTION /DISCONNECT REQUIREMENTS (PER NEC #440) WITH EQUIPMENT MANUFACTURER NAMEPLATE DATA FURNISHED WITH UNIT /MECHANICAL CONTRACTOR PRIOR TO ELECTRICALS ROUGH -IN. MAKE ALL FINAL ELECTRICAL POWER CONNECTIONS. FURNISHED AND INSTALLED BY LANDLORD. LL'S ELECTRICAL LEASE LINE LADY FOOT LOCKER SAC REVISIONS ` NO. DESCRIPTION DATE . ROOM LL. TO PROVIDE 2" CONDUIT ONLY W/ PULL WIRE ETENANT'S E.C. TO PROVIDE 4 43 /0 THLUN AND 1 06 GRD.. EXACT REQUIREMENTS IN FIELD PRIOR TO SIDS. SPACE TENANTS ELEC. CONTRACTOR TO EXTEND CONDUIT AND WIRE AS NEEDED. L.L. TO PROVIDE 1- METER IN LANDLORD PROVIDED 4 TENANTS ELEC. CONTRACTOR TO PROVIDE J -BOX AS NEEDED. -1 0 1 41 REFER TO HVAC CONNECTION SCHEDULE FOR CIRCUITING/WIRE / SIZE /CONDUIT SIZE OF ALL HVAC EQUIPMENT. PANEL 277/480V 100.0 M.C.B. 1 \ - - /� \ / 1 i 1 \/ 1 \ PANEL 30 O4W 8V 150A M.C.B. METER SOCKET. PLANS. DATE: 12/17/07 LANDLORD SHALL PROVIDE 100A /3P CIRCUIT BREAKER IN LANDLORD'S SWITCH GEAR- EXISTING 2-17/450V, 3 ?, 4W, LANDLORD METER PANEL BOARD. FIELD VERIFY EXACT REQUIREMENTS PRIOR TO 8108. TENANT 3 +3 'NUN AND I'1114 E.C. TO PROVIDE .,�C �A �'� C . SCALE: AS NOTED 100A ' GROSS AREA: 2,164 SQ. FT. TO CIRCUITS INDICATED ON PLANS. TENANT E.G. TO PROVIDE 4 01/m TNLLN AND 1 IV, SALES AREA: 1,272 SQ. FT. PROJECT # : 0712260 DRAWN BY: - I 1 /\ 1 N, AND 1 +'8 C=RD. / \ CsRp. AND 2" GONI;7UIT ;, f/ .;:' 1 1 FLOOR I J /;:: CONDUIT / \ � FIELD VERIFY EXACT DISTANCE ■ TENANT E.G. TO PROVIDE EW 45KVA TRANSFORMER •6 amp. TO WILDING -80V, 3PH DELTA PRI. ,I- PER N.E.C. 20 /20SV, 3PH, 4W WYE SEC. TO - l =E RELOCTED. FIELD VERIFY EXACT REQUIREMENTS PRIOR TO BIDS. Lady Foot Locker • 0 EXISTING POWER RISER AND SCHEDULES N.T.S. 1. HVAC CIRCUIT BREAKERS SHALL BE "I-1ACR" TYPE WHERE REQUIRED BY EQUIPMENT NAMEPLATE PER N.E.C. 2. TENANTS ELECTRICAL CONTRACTOR SHALL FIELD VERIFY EXACT A.I.C. RATING OF LANDLORDS DISTRIBUTION EQUIPMENT, FURNISH AND INSTALL TENANTS SYSTEM TO MATCH. 3. ELECTRICAL CONTRACTOR SHALL BALANCE ALL PANELS AND ELECTRICAL EQUIPMENT TO 10% BETWEEN PHASES: A/S, S IC, A/C REGARDLESS OF CIRCUITING INDICATED, 4. PROPER CLEARANCE MUST BE MAINTAINED ABOUT ELECTRICAL EQUIPMENT PER N.E.C. FIELD VERIFY EXACT MOUNTING SPACE AVAILABLE IN ELECTRICAL ROOM /AREA PRIOR TO INSTALLATION OF ELECTRICAL EQUIPMENT. S. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL CONNECTIONS FOR A COMPLETE ELECTRICAL DISTRIBUTION SYSTEM. 6. BOND NEUTRAL TO GROUND AT DISCONNECT SWITCH IF NOT BONDED ON LINE SIDE OF DISCONNECT SWITCH. IF NEUTRAL IS BONDED ON LINE SIDE OF DISCONNECT SWITCH, DO NOT BOND AT DISCONNECT SWITCH. 1. MAXIMUM LENGTH OF TAP CONDUCTORS ON TRANSFORMER SECONDARY SHALL NOT EXCEED 10' -0" IN LENGTH_ S. FIELD VERIFY EXACT MOUNTING SPACE AVAILABLE IN ELECTRICAL ROOM /AREA PRIOR TO INSTALLATION OF ELECTRICAL EQUIPMENT. `. EQUIPMENT NAMEPLATE PER N.E.G. PROJECT TITLE SOUTHCENTER MALL 633 SOUTHCENTER P K Y V ^' PKWY /� TUKWILA, WA, 98188 SPACE #1560 FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THI5 CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE 4 WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR R SHALL ALERT ARCHITECT, ENGINEER DR OWNER OF ANY APPARENT' DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. RECEIVED cl T'OFTUKWILA STORE NO 461 1 SHEET TITLE ELECTRICAL POWER RISER & SCHEDULES JAN u T 6U6 PERMIT CENTER 3 . 0 SHEET NO. 0 POWER RISER GENERAL NOTES . SECONDARY PRIMARY REGISTER REGISTER F 0 0 T LOCKER INC. STORE PLANNING DEPT 112 WEST 34TH STREET NEW YORK, NY 10120 '"° C� FOB � ANC �� O CODE COQ NFRA 70 _n ARCHITECT: JAMES M. HAMILL, A.I.A. 580 DECKER DRIVE, SUITE 170 IRVING, TEXAS 75062 PHONE: (972) 714 -0420 INSTALL ETHERNET CABLE THRU DATA CONDUIT INTO CASH WRAP. ill RJ_45 (MALE) PROJECT CO- ORDINATOR: -_ _: A U L P A R T N E R S H I P P ¢ =L _ TOROTO • CALGARY • VANCOUVER 2660 Sherwood Heights Dr Suite 200, Oakville, Ontario, L6J 7Y8 1- 888 - 855 -5061 fax (905)3371986 > > nin WRAP MANAGER'S DESK �a Cty Of auk BUILD.IL DIVISION i CABLE BLOCK WIRING DIAGRAM 3" GROMMET HOLE \3HGOMMT HOLE 3" GROMMET HOLE 3" GROMMET LADLE CTYP -)— — — CTYP_) CTYPJ (TYP.) — — — ENGINEER — Emphasis On Excellence M- Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 TEL: 614.818.2323 FAX: 614.818.2337 v///////////// J SEAL DEC 1 8 2007 rr- ship . ?.c ((1;T'\ u . :e °� ,. r r,,,,r,��,l „ _7,I r r ECONDAR ECONDAR J PRIMARY I REGISTER I REGISTER PRIMARY I REGISTER RETER WELL L (3) (3) I I 1 ��������� °���• (4604) J (484) L - - - -J (4 84) /L — — — —J L (4�o84) J� ' 110. ::::::CT 0 0 0 0 u J ACCESS POINT JACK ACCESS POINT JACK LIGHT FIXTURE DUPLEX OUTLET FOR SECURITY A e A A/V CONTRACTOR- 100 REVISIONS NO. DESCRIPTION DATE RJ11C PHONE RJIIC PHONE (LINE 1) CLINE 1) CONTRACTOR- TO FURN. AND INST. CONTRACTOR TO FURN. AND INST_ (4) 1" CONDUITS TO WRAPPER= FOUR (4) 1" CONDUITS TO WRAPPER= LAMINATED MGR DESK MANAGER'S DUPLEX OUTLT DESK RECEPTACLE DUPLEX OUTLET AG1 E RECEPTACLE 1_ FOR TELEPHONE 1. FOR TELEPI -ZONE F BUZZER ®® 2. FOR ETHERNET CABLE 2. FOR ETHERNET CABLE 3. FOR DEDICATED ELECTRICAL OUTLETS 3. FOR DEDICATED ELECTRICAL OUTLETS iiiill ® • Plf 4. FOR GENERAL ELECTRICAL POWER 4. FOR GENERAL. ELECTRICAL POWER CONTRACTOR TO FURN. AND INST. ONE CONTRACTOR TO FURN. AND INST. ONE D 120 VOLT, 20 AMP CIRCUIT WITH QUAD OUTLET 120 VOLT, 20 AMP CIRCUIT WITH QUAD OUTLET CIRCUIT (SEPERATE HOT, NEUTRAL, DEDICATED CIRCUIT (SEPERATE HOT, NEUTRAL, DATE: 1 2/1 7/07 UNDER EACH WELL, 2 HUSSEL I.G.#5352 OR UNDER EACH WELL, 2 HUBBEL I.G.5352 OR APPROPRIATE EQUIVALENT, WIRED TO PANEL BOARD APPROPRIATE EQUIVALENT, WIRED TO PANEL BOARD CONTRACTOR TO FURN. AND INST. ONE CONTRACTOR TO FURN. AND INST. ONE � SCALE: AS NOTED NON - DEDICATED DUPLEX OUTLET, WIRED TO NON - DEDICATED DUPLEX OUTLET, WIRED TO PANEL BOARD. PANEL BOARD. RJ11C PHONE JACK (LINE a DEDICATED QUAD OUTLE RECEPTACLE FOR PRINTER SYSTEM- GROSS AREA: 2,164 SQ. FT. SALES AREA: 1,272 SQ. FT. PROJECT # : 0712260 DRAWN BY: A� (2) TWO CASH REGISTER WIRING DETAIL B ' MANAGER DESK WIRING DETAIL Lady Foot Locker 1. CONTRACTOR SHALL INSTALL AN ETHERNET CABLE (TWISTED SHIELDED CABLE) FROM THE MANAGER'S DESK TO CASH WRAP THRU DATA CONDUIT, AND TERMINATE CABLE IN CASH WRAP. NOTE: DO NOT TERMINATE CABLE NEAR OR ON METAL POLES R RA 2. LASLE CABLE AT MANAGER'S DESK AS 'ACCESS POINT'_ 3. CONTRACTOR SHALL INSTALL CABLE LEAVING ANY AND ALL SLACK COIL IN MANAGER'S AREA WITH A MINIMUM OF 12" SLACK AT CASH WRAP. 4. MATERIALS TO BE SUPPLIED BY FOOT LOCKER. NOT IF FOOT LOCKER SUPPLIED ETHERNET CABLE EXCEEDS 75' -0" FROM MANAGER'S DESK TO CASH WRAP, CONTRACTOR TO SUPPLY REPLACEMENT CABLE AS NEEDED, AND RETURN UNUSED CABLE BACK TO CABLE COMPANY. . CONTRACTOR SHALL MAINTAIN A MINIMUM CLEARANCE OF 15 INCHES FROM ALL NOISE EMANATING ELECTRICAL EQUIPMENT (e.g_ BALLASTS, POWER FEEDER CABLES, ETC.) FOR ENTIRE CABLE RUN. 6. CONTRACTOR SHALL PERFORM 4 CONTINUITY CHECK FOR EACH CONDUCTOR TERMINATED AT EACH END OF THE INSTALLED CABLES, INCLUDING CABLE SHIELD- I. CONTRACTOR SHALL LEAVE ONE AS BUILT COPY OF THIS DRAWING WITH STORE MANAGER(S). , RECEIVED CITY OF TUIM/IL4 JAN 0 8 2003 PEHM1T CENTER PROJECT TITLE SOUTHCENTER MALL 633 SOUTHCENTER VA /Y PKWY TU KV1/I LA WV A 98188 , > SPACE #1560 STORE NO. 461 71 SHEET MISCELLANEOUS ELECTRICAL DETAILS SHEET NO. TITLE • 0 4 )) GENERAL NOTES