Loading...
HomeMy WebLinkAboutPermit EL08-0212 - WESTFIELD SOUTHCENTER MALL - ZOUNDS HEARINGZOUNDS HEARING 426 SC MALL 07 -14-08 ELO8-2 12 Parcel No.: Address: Suite No: City Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 426 SOUTHCENTER MALL TUKW ELECTRICAL PERMIT Permit Number: Issue Date: Permit Expires On: EL08 -212 04/29/2008 10/26/2008 Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: ZOUNDS HEARING 426 SOUTHCENTER MALL , TUICWILA WA WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA DEVON REDMAN 1327 POST AVE STE H , TORRANCE CA Contractor: Name: SIGN -TECH ELECTRIC LLC Address: 5113 PACIFIC HWY E, SUITE 12 , Contractor License No: SIGNTEL988BG Phone: Phone: 310 - 328 -6300 X101 Phone: 253 952 6559 Expiration Date: DESCRIPTION OF WORK: INSTALL LIGHTING, RECEPTACLES AND ELECTRICAL PANELS Value of Electrical: $27,000.00 Fees Collected: Type of Fire Protection: National Electrical Code Edition: Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature I hereby certify that I have read an governing this work will be compli $656.00 2005 Date: °Li 10(/ exa ed this permit and know the same to be true and correct. All provisions of law and ordinances wi h, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or th - - • ►- ce of work. I am authorized to sign and obtain this electrical permit. Signature: r Print Name: i�Cl// ihl�/��% Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -212 Printed: 04 -29 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 426 SOUTHCENTER MALL TUKW ZOUNDS HEARING PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL08 -212 ISSUED 03/04/2008 04/29/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Date: S°1 Cr Print Name: doc: Cond -Elec EL08 -212 Printed: 04 -29 -2008 CITY OF TUKWIL4111 Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 nr112.1,4vww c i. tukwila_wa. us Electrical Permit No. Project No. 2r� (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: Tenant Name: �G King Co Assessor's Tax No.: U 3 � - c761 a Suite Number: Floor: 1i �vre q � U New Tenant: Yes ❑..No Property Owners Name: V" 571 �, ) j )r4 /4*_ ✓, c - Mailing Address: 1\ 60 { Ir`�I /� /1r �� / b'!�'lf, t �" •7%r L A C A 900 Z5 City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: Ivy -Q'^-- Day Telephone: Mailing Address: rRO - / ' - f City E -Mail Address: \Je "t°'~` Ce- reSSi2erc •Cr,axNumber: '51' 3 n 3 3 6 ELECTRICAL CONTRACTOR INFORMATION CA- ?o c _a State Zip Company Name: �\ Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ 7: 000 T Scope of Work (plegse provide detailed information): 69 rec vv Will service be altered? ❑ Yes i No Adding more than 50 amps? ❑ Yes �� Type of Use: Jf f Cc -1\- 1 Type of work; New ❑ Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ❑ Puget Sound Energy ❑ Seattle City Light H:\ApplicationsWomu- Applications On Line \4 -21M)7 - Electrical Permit Application doc bh Page I of 2 RESIDENTIAL. NEW RESIDENTIAL SERVICE ❑ New single family dwellings (including an attached garage) ❑ Garages, pools, spas and outbuildings ❑ Low voltage systems (alarm, furnace thermostat) $140.00 $75.00 ca $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CON CTOR: Print Name: %-17 -t e DD nom- Mailing Address: 4,-3,3 Day Telephone: City Date: 3/37d 2. -D $e 2 - E,a 7 ( L A `i8/8- State Zip Date Application Accepted: 3— 9, 08. Date Application Expires: q . s- Staff Initials: )/K K H: Applicalions\Ponns- Apphcabons On ImaW -2007 - Elocbical Pencil Apphcabon.doc bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -212 Address: 426 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 03/04/2008 Applicant: ZOUNDS HEARING Issue Date: Receipt No.: R08 -01396 Payment Amount: $524.80 Initials: JEM Payment Date: 04/29/2008 11:58 AM User ID: 1165 Balance: $0.00 Payee: SIGN -TECH ELECTRIC LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 5641 524.80 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 524.80 Total: $524.80 1768 04/29 9711 TOTAL 524.80 doc: Receipt -06 Printed: 04 -29 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -212 Address: 426 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 03/04/2008 Applicant: ZOUNDS HEARING Issue Date: Receipt No.: R08 -00612 Initials: WER User ID: 1655 Payment Amount: $131.20 Payment Date: 03/04/2008 09:43 AM Balance: $524.80 Payee: EXPRESS PERMITS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 11077 131.20 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 131.20 Total: $131.20 5399 03/04 ''-'.1O TOTAL ;17,80 doc: Receiot -06 Printed: 03 -04 -2008 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION its 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: ©v�•5 Type of Inspection: 2 OQ Address: iii(f ti Date Called: Special Instructions: Date Wanted: '"j f a.m. P.m. Requester: Phone No: Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: K_ Inspector: fr"1 &AI( Date: D"1'14 th ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: -..�. .a..n.� .4.. w..,1aE_7¢ir�.w'�... i— taftieheao _:..a �.. ..:�.lu:lEms_ �N !•�.ss.4W - ��n� I INSPECTION NO. INSPECTION RECORD Retain a copy with permit 64- 212- PERMIT NO. CITY OF TUKWILA BUILDING DIVISION IL 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Z0 v�Dj Type of Inspection: P 00 - %‘,2,E Ft SPA A -r- skit Ai Address: ti �19 lei tivi Date Called: vilakk -n4 kd 9 co ad6ar C, 49 i iskl Cod D tIGTD LL IA I C.aA) V)JiT" Special Instructions: Date Wanted: -7 /07 p.m. Requester: Phone No: ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: -40142--lrer--"V"--1411435,4` - %‘,2,E Ft SPA A -r- skit Ai Dric ar oifelAtAC.4 LI ..41 r 1PJ 1 f r 1)01- 117 CoDE at,, I - 15 Atie B 0 Kf4viUt) wMt( vilakk -n4 kd 9 co ad6ar C, 49 i iskl Cod D tIGTD LL IA I C.aA) V)JiT" Inspector: iith1A16, Date: D7/0/ 1 Q1 • El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: !Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit 409- z,2-1 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 7 Reog. to: i/N c Type of Inspect 703 Addit ! I_ ` 6- Date Called: Special Instructions: Date Wanted: t. /� a.m. � Requester: '' Phone No: proved per applicable codes. Corrections required prior to approval. COMMENTS: C/_ CL! /A)6- c/JIJa, 6A/A G.fiL /NG$ Inspector VIL 130-411--EMN Date: 7,/ /Of D $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit f- GOsf —z/� PERMIT NO. ra.- (206)431 -3670 0gAVA.} //44/1141 � Type of Inspection: 003 gddre ;l/s: 44 All- Date Called: Special Instructions: Date Wanted: �r.• / / _` e" a.m. p.m. Requester: Phone No: A • :roved per applicable codes. EiCorrections required prior to approval. / OMMENTS: /n4 Inspec 1/10 r48% agfr Date: r/2 g/ r ❑ $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 p •ii "�1 /iU ('� f!< Type of InspectjgP� ( — A dre s: „, 11 hAt .giI PiriAlii, ; , iLL Date Called: SpeciAl Instructions: Date Wante / /f � a.m. p.m• Requester: Phone No: proved per applicable codes. Corrections required prior to approval. COMMENTS: ( — cf-41//C-r--- / / ' t/ / / Intyt9rf (brcJ2I7/jf6,f1 Date: .s // /y_ Ej $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Pro elct: ���r - iVot1 5 I /14 ` //ice Type of Inspection: "'� f / Vin:` frke0 „y)eGL �f Date Called: Special Instructions: Date Wanted: / 5-76 Requester: Phone No: roved per applicable codes. .•r Corrections required prior to approval. 7 MMENTS: ?; - N t`(_-1946 Insgf�G 7��4 0G4" 0 $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lig�i'ting Summary; 2006 Washington State Nonresidential Energy Code Compliance Forms Ls LTG -INT Reis ed Ju Project Info Project Address Jr' or Building Applicant Address: Applicant Phone: Project Description. Compliance Option New Building a Addition ® Alteration ® Plans Indud Indicate controls (Sections 1513) including commissioning requirements 10 Prescriptive 0 Lighting Power Allowance 0 Systems Ana (See Qualification Checklist (over). hdicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions �® No changes are being made to the lighting (check appropriate box - sec. 1132.3) ® Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Retail apace merchandise display WALL RETAIL STORE OccupanccDescription Allowed Wang, ner ft2** Area in ft2 Allowed x Area 1.50 1790.0 2685.0 WALL RETAIL STORE 1.50 1532.0 2298.0 From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 4983.0 Vroposea Lignring vvarsage Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed (floor/room n0.1 Retail space A: 2'x2' Parabolic Troffer W/ 3 -T8-u1 lamps i LB 6 96 576.0 Retail apace a: 2'x4' Parabolic Trotter W /3 -T8, 32 watt lamps i E9 4 96 384.0 merchandise C: Lighting Track with 75 watt (max.) PAR-30 head's 12 50 600. 0 display Retail space CL2: Fluor. Cove Lighting W/ 1 -T8, 17 watt lamp i Ee 1 17 17.0 Retail space CL4: Fluor. Cove Lighting W/ 1 -T8, 32 watt lamp i 8B 6 32 192.0 Retail space D: 6" Rec. CF downlight W/ 1- 32watt lamp i EH 9 32 288.0 Retail space 01: 7" rec. incd. downlight W/ 100 watt (max.) lamp 2 100 200.0 merchandise D2: 7" rec. incd. wallwsaher W/ 90 watt (max.) lamp 6 90 540.0 display merchandise D3: HONOPOIIfl W/75 watt (max.) lamp 9 75 675.0 display Retail space F: Fluorescent strip light W/2 -17 watt lamps i ES 1_ 34 34.0 Retail space 71: Fluorescent strip light W/2 -32 watt lamps 6 E9 4 64 256.0 merchandise G: Display light N/3 -18.5 watt LED lamps 2 55.5 111.0 display Retail space S1: Incd. wall sconce W/1 -100 watt (max.) lamp 2 100 200.0 Retail space IC: Incd. pendant light W/4 -60 watt(max.) lamps 1 240 240.0 Retail space 52: Incd. pendant W/1 -100 watt (max.) lamp 2 100 200.0 Retail space T: Bathroom exhaust !an N/1 -100 watt (max.) lamp 1 150 150.0 Tntal Proposed Watts may not exceed Total Allowed Watts for hterior Total Proposed Watts fie. _ FILE COPS 2[11 4 2008 PERMiT (EN -I t. 2006 Washington State Nonresidential Energy Code Compliance Form Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's fisted maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual . may also be used. For track lighting, list the greater of actual Iuminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. kUl f- e rr • ,4R..t� u , q., r.Kt4 � dt/44/0 2 -27 4 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary (back) 2006 Was him ton State Nonresidential Energy Code Compliance For LTG -INT Re 4sed July 2007 Prescriptive Spaces Occupancy. O Warehouses, storage areas or aircraft storage hangers • Other Qualification Checklist Note: If occupancy type is 'Other' and fixture answer is checked, the number of fixtures in the space is not limited by Coda. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) 0.9 Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T -1, T -2, T-4, T -5, T-8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. • Convention center TAt3Lt 1b -1 unti LlgnIng rower fanuwanve k.r.+r LPAZ(Wlsf) Use' LPA (W /sf) Use' Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools hospitals, institutions, museums, banks, churches) 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations 1.0 Cafeterias, fast food establishments5, 1.3 Post office 1.1 restaurants/bars5 Dormitory 1.0 Retail'0 retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gvmnasiae. assembly spaces' 1.0 Theater, motion picture 1.2 Health clinic 1.0 Theater, performing arts 1.6 care Hospital, nursing homes, and other Group 1 -1 and 1 Occupancies 1.2 Transportation 1.0 -2 Hotel /motel 1.0 Warehouses ", storage areas Hotel banauedconference /exhibition hall" 2.0 Workshops 4 Laboratory spaces (all spaces not classified laboratory' shall meet office and other appropriate 1.8 Parking garages 0 categories) Laundries 12 , Libraries5 1.3 Plans Submitted for Common Areas OnIy Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms. elevator lobbies 0.8 Footnotes for Table 15-1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W/ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three- quarter - height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w/ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling - mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. • PER ', IT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -212 DATE: 03 -04 -08 PROJECT NAME: ZOUNDS HEARING SITE ADDRESS: 426 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: j DuTiding' c, Division Public Works n Fire Prevention Structural Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 03 -06 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS R UTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required n DATE: APPROVALS OR CORRECTIONS: Approved Notation: Approved with Conditions DUE DATE: 04 -03 -08 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Look Up a Contractor, Elects an or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License SIGNTEL988BG Licensee Name SIGN -TECH ELECTRIC LLC Licensee Type ELECTRICAL CONTRACTOR UBl 602152490 Ind. Ins. Account Id Business Type LIMITED LIABILITY COMPANY Address 1 5113 PACIFIC HWY E #12 Address 2 City FIFE County PIERCE State WA Zip 98424 Phone 2539222146 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/7/2002 Expiration Date 1/7/2010 Suspend Date Separation Date Parent Company Previous License Next License Associated License MORRIT *943K6 Electrical Administrator Information License MORRIT *943K6 Name MORRISON, TRAVIS Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date MENDENHALL, JOHN C PARTNER/MEMBER 01/07/2002 MENDENHALL, LINDA D PARTNER/MEMBER 01/07/2002 • Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= SIGNTEL988BG 04/29/2008 r t2 CO- r-1- Lighting Plan 4!r ,1f. LA -7 LA -19 VIA T.C. LA -37 �T T011 F.- COM D2 LOUNGE LA-1 ECtRESS CORR. PANEL "LA" I LTG. RELAY PNL. NOTE: ELECTRICAL CONTRACTOR TO VERIFY EXACT LOCATION OF ALL DEVICES BEING INSTALLED BEHIND FIXTURES TO ENSURE THAT DEVICES ARE LOCATED AT CUTOUTS IN BACK OF FIXTURE. NOTE: T.G.C. TO REFER TO SHEET A-4 FOR QUANTFTY AND LOCATION OF LIGHT FIXTURES. THAT SHEET WILL TAKE PRECEDENCE IF THERE ARE ANY DISCREPANCIES BETWEEN SHEET E -1 AND A -4. GRX RS232 INTERFACE NOTE: LIGHTING RELAY PANEL AND CONTROLS SYSTEM SHALL BE "COMMISSIONED" PER WASHINGTON STATE ENERGY CODE REGULATIONS. ;SEE PLAN NOTES 3 & 6. 2 1 4 8 FEET NOTE: 2006 IBC - Sec. 1 006 Provide an average of one foot - candle illumination at the floor along the entire egress pathway and exit discharge 2 Electrical Specification E -1 16000 - ELECTRICAL SPECIFICATION 1. General The General Conditions, Special Conditions, Supplementary Conditions and Electrical Specifications contained in the main mall Specifications, and AIA "General Conditions of the Contract ", current edition, shall apply to all work on this project except as modified herein. This Contractor shall also refer to the Architectural, Structural, and Mechanical Plans and Specifications, which are Contract Documents. Bidders shall visit the site and familiarize themselves with all conditions surrounding the work prior to submitting their bid. Any discrepancies shall be called to the Architect's attention. No subsequent allowance will be made in this connection for any error or negligence on the contractor's part. 2. Requirements All work shall meet the current National Electrical Code or applicable local electrical code, all other applicable codes, all utility requirements, and all Landlord requirements as to construction and insurance. This Contractor shall procure and pay for all required permits and utility service charges required for the execution of this work and shall make any necessary arrangements for electric connections to tenant area as required. Contractor shall obtain rough -in and final electrical inspection approval certificates for all electrical work. Electrical Contractor shall provide circuit directory with typed circuit designation card under plastic cover on the inside of each panel door. Electrical Contractor shall also furnish and install nameplates on all other enclosures, disconnect switches and panelboards. Each nameplate shall be black laminated micarta with 1/4 inch high white letters, describing panel designation and voltage characteristics, and shall be permanently affixed to outside surface of door by means of metal screws. 3. Guarantee This Contractor shall unconditionally guarantee all work under this Contract to be free from defects in workmanship and materials for a period of one year from the date of final acceptance of the work by the Tenant. Contractor shall make good all such faulty items identified to him during this period without cost to Zounds. 4. Plans and Specifications It is the intent of the Plans and Specifications to provide for a complete installation. Everything necessary for the completion and successful operation of the work, whether or not herein definitely specified or indicated shall be furnished and installed as if so specified or indicated without additional cost to Zounds "Provide" means to furnish and install. The drawings are diagrammatic and not intended to show exact locations unless dimensioned. This Contractor shall verify all dimensions and lengths, and shall adjust his equipment and raceway locations to avoid conflicts with other construction or equipment. If any errors, discrepancies or omissions appear in the Plans and Specifications or other Contract Documents, the Contractor shall notify the Engineer, or, failing to do so before construction and /or fabrication of the work, shall be held responsible for the results of any such errors, discrepancies or omissions and the cost of rectifying same. Minor adjustments to the Plans and Specifications, including equipment voltage requirements and outlet locations, may be requested by Zounds during the project. Contractor shall make such adjustments without additional cost to the Tenant, where such adjustments are necessary to the proper installation and operation and within the intent of the Contract Documents. WIRING DIAGRAM NOTES: 1. GRX 3104 DIMMER - FLUSH MOUNTED 48 "A.F.F. AND 16" FROM DOOR FRAME TO CENTERLINE OF UNIT. 2. GRX -FDBI INTERFACE TO BE MOUNTED IN 2 GANG BOX, LOCATED ABOVE THE DROPPED CEILING, IN AN ACCESSIBLE LOCATION. 3. GRX -RS -232 INTERFACE IS HOUSED IN A FLUSH MOUNTED SINGLE GANG BOX BEHIND THE CABINET AT 12" AFF; SEE SHEET TD -1 FOR EXACT LOCATION. 4. DIMMER PACK TO BE INSTALLED IN FOUR FLUSH MOUNTED SINGLE GANG JUNCTION BOXES ATTACHED HORIZONTALLY AT 48" AFF. ELECTRICAL CONTRACTOR TO PROVIDE POWER IN CONDUIT FROM JUNCTION BOXES TO A DEDICATED CIRCUIT WITH HANDLE LOCK ON A 120/208 VOLT PANEL. 5. LUTRON DIMMER SYSTEM IN DEMO ROOM FURNISHED BY TENANT FOR INSTALLATION BY ELECTRICAL CONTRACTOR. ALL WIRING AND CONDUIT PROVIDED BY ELECTRICAL CONTRACTOR. Demo Room Lutron Wiring Diagram NOT TO SCALE 5. Installation All electrical work shown and required shall be by Electrical Contractor, unless otherwise stated, who shall furnish and install all minor items obviously and reasonably necessary for the completion of the work, and make final connections. All cutting and patching of existing conditions required for the work of this Contract shall be by this Contractor. All temporary wiring shall be furnished, installed and removed by this Contractor. 6. Lighting Fixtures All recessed light fixtures must be installed to provide a non- combustible fire rated assembly as specified under ceiling construction. Recessed incandescent fixtures shall be connected by means of flexible conduit and 150 degree centigrade wire run to a branch circuit outlet box independent of the fixture. 7. Wiring Devices Wiring devices shall be specification grade, by architect, side - wired, 20 amp with ground, Hubbell No. 1221 and 1223 series switches, 5362 series receptacles; or equal products of Lutron, Slater, Sierra, or Arrow-Hart. Isolated ground outlets shall be Hubbell No. IG -5362. Plates shall be smooth plastic. Junction boxes, and outlet boxes for light fixtures, receptacles and wall switches shall be galvanized knockout type, except cask waterproof type shall be used in wet locations. Lighting fixture outlets shall not be less than 4" octagonal_ Cover plates to be white(U.N.O.). Electrical contractor to coordinate locations with general contractor and architectural drawings. 8. Conduit and Wire All wiring shall be installed in steel conduit unless otherwise indicated or specified. Conduit shall be EMT, except all conduit in concrete slab or masonry construction or exposed to weather shall be 3/4" minimum galvanized IMC, and short final connections to mechanical equipment, lighting fixtures, and transformers shall be FMC (or LTFMC if in a wet location). Conduit shall be concealed in all finished areas of the space. Fittings shall be set screw or compression type as appropriate, except fittings for IMC shall be threaded waterproof with anti -seize compound. Conduit shall not be run through or attached to HVAC ducts. All wire shall be copper, Type THHN, or as noted, No. 12 AWG stranded minimum, or as shown. Wiring, within light fixtures and other high temperature equipment shall have 150 degree Celsius insulation as required by NEC. All wiring shall be color coded throughout as follows: 277Y/480 volt system Phase A - Brown Phase B - Orange Phase C - Yellow Neutral - Grey 208Y/120 volt system Phase A - Black Phase B - Red Phase C - Blue Neutral - White Color code shall identify the same phase throughout the system from service switch or transformer through all branch circuitry. APPROVED i" , • •ry �.�r �A-nr) e. 7N J p•n' r- •t ' i iLir't:u CR ALTERED WITHOUT AUTHORIT.AT!ON FROM THE BUIN , AU WORK SHALL BE DeNE IN ACCORDANCE WITH THE APPROVED PLANWO 16 TO F;LC !NSPECTTCNa, GRX - FDBI -16A -120 (FLUORESCENT DIMMING BALLAST INTERFACE) LUTRON GRX 3104 -T -WHITE 4 CH. IN WALL DIMMER PACK 2000W TOTAL 800W /CH. MAX. DUAL TWISTED PAIR 18AWG- 1/2"C. GRX RS232 INTERFACE BEHIND CABINET (LOW LEVEL DEVICE) LUTRON CH. 1 CL2 CL4 COVE LIGHTS LUTRON CH. 2 LUTRON CH. 3 ‘8' D3 LUTRON CH. 4 RESERVED 9. Electrical Equipment All equipment shall be new, UL listed, commercial grade, and weatherproof if exposed to weather. This Contractor shall order equipment within ten days of receipt of Contract and submit copies to Engineer of all equipment purchase orders to verify timely ordering of specified equipment. Substitutions after this date will not be approved due to lack of placement or order. This Contractor shall provide the General Contractor with a minimum of five certified copies of all shop and equipment drawings for his approval, two of which shall be retained by the Engineer, the remaining being returned to the Contractor. Electrical Contractor shall coordinate with Mall's electrical requirements Unless otherwise indicated on Plans. Surge protector shall be UEBERT ACCUVAR #ACV - 208 -Y- 111 -RE. All panels, transformers and disconnects shall be identified by means of engraved nameplates with white lettering on a black background. RELAY PANEL SHALL BE LUTRON MODEL: XPS16- 12OFT. LOW VOLTAGE WALL SWITCHES SHALL BE LUTRON MODEL: SO- 4BN- WH -EGN CEILING MOUNTED OCCUPANCY SENSORS SHALL BE LUTRON MODEL: LOS - CDT - 500 -WH INTERCONNECT CABLES BETWEEN SWITCHES, SENSORS AND PANEL SHALL BE LUTRON: GRX - PCBL -46L (Plenum rated). The panel door shall contain a typewritten branch circuit directory. Wires shall be identified for all branch circuits using approved wire markers. Disconnect switches shall be NEMA, Heavy Duty, 3p, fused per equipment manufacturer's specifications and recommendations. Floor box to be Hubbell type PFB1 with adapter ring (PFBA1) and black cover PFBCBL. Provide with duplex receptacle. 10. Telephone Landlord is to supply a 1" conduit to the Zounds space. It is the Electrical Contractor's responsibility to provide a complete telephone system including all power, backboards, term etc. for this installation. See sheet TD -1 for additional information. 1 1 _ Mechanical Equipment Line voltage wiring of HVAC equipment, if required, shall be the responsibility of the Electrical Contractor. The Electrical Contractor shall verify requirements with the Mechanical Contractor. Electrical Contractor to furnish and install conduit in walls for temperature control devices. 12. Door Buzzer System Buzzer System equipment shall be Edwards: Buzzer #340- 4G5- 24VAC, 852 Weatherproof Pushbutton and 592 Transformer. Buzzer system wire need not to be installed in conduit unless required by Landlord. Wiring not in conduit shall be plenum rated. CL4 1 S F. A. AUDIOVISUAL - SIGNAL (IF REQUIRED) - "--- E -z F. A. PULL STATION (IF REQUIRED LIGHT SWITCHES TELE /DATA OUTLETS RECEPTACLES +� FINISHED FLOOR Egress Corridor RELAY PANEL "LC" TO: PANEL LA Rear Entry SLV1 Ceiling Mounted Occupanc Sensor Front Entry SLV2 A A Lutron cable GRX - PCBL -46L (Plenum rated). Low Voltage Wiring Diagram (-g- -1/ NOT TO SCALE Light Fixture Schedule 16000 - LIGHTING SYMBOL QUANTITY DESCRIPTION MFR. STYLE/ VOLTS/ CAT. NO. LAMPS COMMENTS 2'x2' Recessed Fluorescent, w/ Parabolic Troffer Lightolier DPA2G9LF 32U12003 (3)FB031 / 835 120V Sales Area B 2'x4' Recessed Fluorescent, w/ Parabolic Troffer Lightolier DPS2G18L P332- 12003 3 -T8 120V Office, Exam Rooms Track Head Light CA Lightolier 9023-WH, 75W PAR 30 NSP /H -C 120V Soles Area C2 /C4 /C8 Surface Mounted Track Lightolier 6002/6001/ 6000 WHITE Sales Area CL4 CL2 4'- 0 "/2'-0" Recessed Cove Lighting Lightolier CL12 CL14 T8 -F17, F32 Demo Room With Lutron Eco -10 Series Dimmable Ballasts D Recessed Compact Fluorescent Down Light Lightolier 8021 CCDW - 6132BU- 1951 PLT /32/4P/ /D830 Sales Area D1 0 Recessed Downlight - Specular Clear Lightolier 1104IC -- 1144 75W PAR 30S /CAP NFL 120V Restaurant Room D2 Recessed Adjustable Dn. Light Lightolier 1102P1- 1129CL 60W PAR38 Cap /FL 120V Sales Area, Cashwrap, Restaurant Room D3 Track Head Light w/ Monopoint Lightolier 9023 -WH, 6190 -WH 50W PAR 30 NSP /H -C 120V Sales Area 0 N/A D4 4'? Recessed Incandescent Downlight ® EM Recessed Emergency Light with 90 Minute Battery Backup DUAL -UTE EZ -2R 120 Volts 8W Sales Area F Surface Mounted 2' Fluorescent Strip Lightolier SW2S217 HPF12050 2 -20TS 120V Tel /Data Closet Egress Corridor Surface Mounted 4' Fluorescent Strip Lightolier SW4S232 HPF12004 2-4ORS 120V Breakroom Pair of Cabinet Light Fixture Kichler 10566 WH Series 1 22" Long (3) 12V, 18.5W Xenon N/A H1 •' H2 Wall Sconce Wall Sconce Kichler Kichler 6966BK 6520N1 100W 120V • N .4- .3 0 u7 f4 -n (P 1 1 -t (D w t in • M M 0 3 o U) C it X HI CD CV 1- a 0 0 z 0 W U ww 0 5 tx a.. u PROJECT COORDI N ATi ON: a® Ch N c.17,4 CD 0 4 . m g M ea E 1.11 Sales Area Interactive Display, Centered Vertically and Horizontally in Rear Wall of Alcove Install w /Lens Side Up Restaurant Room Center on wall at 7' -O" A.F.F. to bottom Lighting Relay Panel Control Matrix CE �/ 8' -6" OR LOWER 18" AFF F 1 1 42" AFF 48 AFF E X I T 75 PROVIDE OR STRUCTURE IXCEEDS ROVIDE PENDANT WHERE HUNG 8' -6° AFF 6' -8" MIN.46" COUNTER AFF TO CL. DETAIL NOTES: 1. INSTALL DEVICES ON ONE COMMON VERTICAL CENTERLINE. (UNLESS OTHERWISE NOTED) 2. INSTALL DEVICES AT THIS HEIGHT WHEREVER APPLICABLE. (UNLESS OTHERWISE NOTED) 1-4 Typical Device Mounting Height Detail: NOT TO SCALE FILE ' PY Permit No. Plan review approval is subject to errors mid mss. Approval of construction documents does not authorize the violation of any adopted code or ordnance. Receipt of approved Field condtions is acknowledged: By Date: City of Tukwila BUILDING DIVISION N /A N/A N /A �K ®K2 Pendant Mounted Fixture Kichler 2768N1 Demo Room Centered on Ceiling Grid 7' -6" A.F.F. to bottom of fixture Pendant Mounted Fixture Kichler 3030N1 Cashwrap 7' -6" A.F.F. to bottom of fixture Mono -Point Incandescent Wall Washer Lightolier 6422-WH Q150CL DC -ETC 120V REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC T Combination Fan/ Light NUTONE 8664RP 120 Volts 1 -100W Toilet Room MAR 2 6 2008 ji;IF City 1f Tukwila MING DIVISION (2) Head Emergency Light Astralite Breakroom, Demo Room UC Surface Mounted Under Counter Fluorescent LED STYLE Exit Sign Designates Night -light Neon Astralite TP -U -R- W-EM 2.4WATT L.E.D. Ceiling mounted Sales Area, Breakroom NOTE 1: TENANT LIGHT FIXTURE VENDOR IS RESPONSIBLE FOR VERIFYING THE QUANTITIES ON THE LIGHT FIXTURE SCHEDULE WITH THE REFLECTED CEILING PLAN. LIGHT FIXTURES ARE TO BE FURNISHED BY TENANT AND INSTALLED BY T.G.C. Lighting Plan Notes: 1. REFER TO SHEET A -4 FOR LIGHT FIXTURE QUANTITIES. SEPARATE PERMIT ' REQUIRED FOR: Mechanical ❑ Electrical le Plumbing tif Gas Piping 1 City of Tukwila LBUILPIt4Q DIVISION 2. FOR ALL EMERGENCY LIGHTS, EXIT SIGNS AND NIGHT LIGHTS, PROVIDE LOCK -ON AT BREAKER HANDLE. PER NEC ARTICLE 700 -12(F) WIRE EMERGENCY LIGHTS AND EXIT SIGNS AHEAD OF ALL SWITCHES. 3. PROVIDE MANUAL, ELECTRONIC DIMMER SWITCH MOUNTED ON SIDE WALL OF ALCOVE O 54" A.F.F. DIMMER SHALL BE LUTRON, NOVA T SERIES MODEL # NELV -450. DIMMER SHALL CONTROL TYPE "G" FIXTURE ONLY. 4. HARD DECK ON THIS PROJECT IS 17' -6" ABOVE FINISHED FLOOR. ALL SUSPENDED LUMINAIRES SHALL BE PROPERLY SUPPORTED WITH THIS IN MIND. 5. LIGHT FIXTURES "D2 ", "D3' AND ALL TRACK FOR TRACK LIGHT FIXTURES TO BE CENTERED OVER WALL FIXTURES /GRAPHICS UNLESS OTHERWISE NOTED. 6. INSTALL TWO (2) TYPE "G" FIXTURES, ONE AT 60" AFF AND ONE AT 66" AFF. CONNECT WITH MODEL # 10571, 9" INTERCONNECTING CABLE. 7. RESERVED 8. ALL EXIT AND EMERGENCY LIGHTS ARE REQUIRED TO HAVE A 90 MINUTE BATTERY BACK -UP. REVISIONS ^j No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional pan review fees j :G Public Works, Building Dion PERMFI NUMBER ARNEw �ee ELO82iz FILE COPY RECEIVED MAR 0 4 2008 ?ERMIT CENTER SHEET NUMBER E -1 SHEET 17 OF 18 RELAY PANEL CONTROL MATRIX RELAY # PNCIL. R. '� LA" ROOM(S) /AREA(S) O.S. WALL SW. 1 1 CORRIDOR LIGHTING Y LV1, LV2 2 3 EXAM ROOM # 1 N S1 3 3 EXAM ROOM # 2 N 51 4 3 EXAM ROOM # 3 N 51 5 3 CONSULTATION ROOM N 51 6 5 SPARE - - 7 7 RESTAURANT ROOM N SD, SD 8 9 LOUNGE N LV1, LV2 9 11 DEMO ROOM N GSX 10 13 OFFICE Y 51 11 13 BREAK ROOM Y 51 12 13 BATHROOM N 51 13 15 STORE FRONT SIGN N TC 14 17 MERCHANDISE DISPLAYS N LV2 15 19 FRONT OF STORE N TC 16 - SPARE - NOTATIONS: LV1 = LOW VOLTAGE SWITCH AT BACK DOOR (BY- PASSES TIME CLOCK) LV2 = L.V. SW. AT FRONT DOOR (UPPER SW. BY- PASSES TIME CLOCK, LOWER SW. TURNS DISPLAY LIGHTS OFF) Y = YES N = NO TC = TIME CLOCK S1 = STANDARD WALL SWITCH Light Fixture Schedule 16000 - LIGHTING SYMBOL QUANTITY DESCRIPTION MFR. STYLE/ VOLTS/ CAT. NO. LAMPS COMMENTS 2'x2' Recessed Fluorescent, w/ Parabolic Troffer Lightolier DPA2G9LF 32U12003 (3)FB031 / 835 120V Sales Area B 2'x4' Recessed Fluorescent, w/ Parabolic Troffer Lightolier DPS2G18L P332- 12003 3 -T8 120V Office, Exam Rooms Track Head Light CA Lightolier 9023-WH, 75W PAR 30 NSP /H -C 120V Soles Area C2 /C4 /C8 Surface Mounted Track Lightolier 6002/6001/ 6000 WHITE Sales Area CL4 CL2 4'- 0 "/2'-0" Recessed Cove Lighting Lightolier CL12 CL14 T8 -F17, F32 Demo Room With Lutron Eco -10 Series Dimmable Ballasts D Recessed Compact Fluorescent Down Light Lightolier 8021 CCDW - 6132BU- 1951 PLT /32/4P/ /D830 Sales Area D1 0 Recessed Downlight - Specular Clear Lightolier 1104IC -- 1144 75W PAR 30S /CAP NFL 120V Restaurant Room D2 Recessed Adjustable Dn. Light Lightolier 1102P1- 1129CL 60W PAR38 Cap /FL 120V Sales Area, Cashwrap, Restaurant Room D3 Track Head Light w/ Monopoint Lightolier 9023 -WH, 6190 -WH 50W PAR 30 NSP /H -C 120V Sales Area 0 N/A D4 4'? Recessed Incandescent Downlight ® EM Recessed Emergency Light with 90 Minute Battery Backup DUAL -UTE EZ -2R 120 Volts 8W Sales Area F Surface Mounted 2' Fluorescent Strip Lightolier SW2S217 HPF12050 2 -20TS 120V Tel /Data Closet Egress Corridor Surface Mounted 4' Fluorescent Strip Lightolier SW4S232 HPF12004 2-4ORS 120V Breakroom Pair of Cabinet Light Fixture Kichler 10566 WH Series 1 22" Long (3) 12V, 18.5W Xenon N/A H1 •' H2 Wall Sconce Wall Sconce Kichler Kichler 6966BK 6520N1 100W 120V • N .4- .3 0 u7 f4 -n (P 1 1 -t (D w t in • M M 0 3 o U) C it X HI CD CV 1- a 0 0 z 0 W U ww 0 5 tx a.. u PROJECT COORDI N ATi ON: a® Ch N c.17,4 CD 0 4 . m g M ea E 1.11 Sales Area Interactive Display, Centered Vertically and Horizontally in Rear Wall of Alcove Install w /Lens Side Up Restaurant Room Center on wall at 7' -O" A.F.F. to bottom Lighting Relay Panel Control Matrix CE �/ 8' -6" OR LOWER 18" AFF F 1 1 42" AFF 48 AFF E X I T 75 PROVIDE OR STRUCTURE IXCEEDS ROVIDE PENDANT WHERE HUNG 8' -6° AFF 6' -8" MIN.46" COUNTER AFF TO CL. DETAIL NOTES: 1. INSTALL DEVICES ON ONE COMMON VERTICAL CENTERLINE. (UNLESS OTHERWISE NOTED) 2. INSTALL DEVICES AT THIS HEIGHT WHEREVER APPLICABLE. (UNLESS OTHERWISE NOTED) 1-4 Typical Device Mounting Height Detail: NOT TO SCALE FILE ' PY Permit No. Plan review approval is subject to errors mid mss. Approval of construction documents does not authorize the violation of any adopted code or ordnance. Receipt of approved Field condtions is acknowledged: By Date: City of Tukwila BUILDING DIVISION N /A N/A N /A �K ®K2 Pendant Mounted Fixture Kichler 2768N1 Demo Room Centered on Ceiling Grid 7' -6" A.F.F. to bottom of fixture Pendant Mounted Fixture Kichler 3030N1 Cashwrap 7' -6" A.F.F. to bottom of fixture Mono -Point Incandescent Wall Washer Lightolier 6422-WH Q150CL DC -ETC 120V REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC T Combination Fan/ Light NUTONE 8664RP 120 Volts 1 -100W Toilet Room MAR 2 6 2008 ji;IF City 1f Tukwila MING DIVISION (2) Head Emergency Light Astralite Breakroom, Demo Room UC Surface Mounted Under Counter Fluorescent LED STYLE Exit Sign Designates Night -light Neon Astralite TP -U -R- W-EM 2.4WATT L.E.D. Ceiling mounted Sales Area, Breakroom NOTE 1: TENANT LIGHT FIXTURE VENDOR IS RESPONSIBLE FOR VERIFYING THE QUANTITIES ON THE LIGHT FIXTURE SCHEDULE WITH THE REFLECTED CEILING PLAN. LIGHT FIXTURES ARE TO BE FURNISHED BY TENANT AND INSTALLED BY T.G.C. Lighting Plan Notes: 1. REFER TO SHEET A -4 FOR LIGHT FIXTURE QUANTITIES. SEPARATE PERMIT ' REQUIRED FOR: Mechanical ❑ Electrical le Plumbing tif Gas Piping 1 City of Tukwila LBUILPIt4Q DIVISION 2. FOR ALL EMERGENCY LIGHTS, EXIT SIGNS AND NIGHT LIGHTS, PROVIDE LOCK -ON AT BREAKER HANDLE. PER NEC ARTICLE 700 -12(F) WIRE EMERGENCY LIGHTS AND EXIT SIGNS AHEAD OF ALL SWITCHES. 3. PROVIDE MANUAL, ELECTRONIC DIMMER SWITCH MOUNTED ON SIDE WALL OF ALCOVE O 54" A.F.F. DIMMER SHALL BE LUTRON, NOVA T SERIES MODEL # NELV -450. DIMMER SHALL CONTROL TYPE "G" FIXTURE ONLY. 4. HARD DECK ON THIS PROJECT IS 17' -6" ABOVE FINISHED FLOOR. ALL SUSPENDED LUMINAIRES SHALL BE PROPERLY SUPPORTED WITH THIS IN MIND. 5. LIGHT FIXTURES "D2 ", "D3' AND ALL TRACK FOR TRACK LIGHT FIXTURES TO BE CENTERED OVER WALL FIXTURES /GRAPHICS UNLESS OTHERWISE NOTED. 6. INSTALL TWO (2) TYPE "G" FIXTURES, ONE AT 60" AFF AND ONE AT 66" AFF. CONNECT WITH MODEL # 10571, 9" INTERCONNECTING CABLE. 7. RESERVED 8. ALL EXIT AND EMERGENCY LIGHTS ARE REQUIRED TO HAVE A 90 MINUTE BATTERY BACK -UP. REVISIONS ^j No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional pan review fees j :G Public Works, Building Dion PERMFI NUMBER ARNEw �ee ELO82iz FILE COPY RECEIVED MAR 0 4 2008 ?ERMIT CENTER SHEET NUMBER E -1 SHEET 17 OF 18 SECURITY AND DATA SYSTEMS INSTALLED HERE. LA -18 TERMINATE CONDUITS AT JUNCTION BOX FLUSH IN WALL AT 18" AFF. TRENCH FLOOR FOR (2) 1" CONDUITS TO CASHWRAP (1- SPARE). SEE DWG TD -1 FOR ADDITIONAL CONDUITS TO CASHWRAP FOR LOW VOLTAGE WIRING. /-Th LA 12 14 68" AFF; SEE PLAN NOTE #4 �- LB -5 CASHWRAP TRENCH FLOOR AT THIS LOCATION. AUDIOMETRIC EXAM SUITE " TEL /DATA LB -4 LOCATION OF -TELEPHONE BACKBOARD. IG CONNECTIO WATER H ABOVE T OF TER EILING IN AREA <EF> EXHAUST FANS ARE PART OF COMBO LIGHT FIXTURE, BY E.C.. \, AUDIOMETRIC EXAM SUITE LA -14 J J LA--22 f r ESTAURANIT ,,','" SIMULATION ROOM , SALES INTERACTIVE LA-22 LB -2 LA -29 LB -6 LOCATE UNDER SEE POWER PLAN NOTE #8 INTERNALLY ILLUMINATED SIGN LOUNGE TOILET ROOM CONSUL ATION LA -22 EGRESS CORR. 74" AFF; PLAN NOT LA -16 DEMO C.L. LA ---16 SEE POWER LA -28 o. is SEE POWER PLAN - NOTE # 9 LANDLORD'S RELOCATED FUSED DISCONNECT INTERCEPT AND EXTEND EXISTING 200 AMP, 277/480 VOLT 3 PHASE, 4 WIRE ELECTRICAL SERVICE TO NEW LOCATION SHOWN. MATCH EXISTING INCOMING WIRING TO DISCONNECT. RELOCATE DISCONNECT TO NEW LOCATION SHOWN. Loc ers W \ \ LA-42 LA PANEL "LA" PANEL "LB" TRANSFORMER LTG. RELAY PNL. 30A -1P 25AF 24,735 aic EXISTING r * 11 200A -3P I i 60 -AF L ' INSTALL NEW CURRENT LIMITING FUSES 3 #4 AWG PHASE /NEUTRAL 1 #10 AWG GROUND 1" CONDUIT S 20,027 aic 45KVA XFM R * 2 1 L J 31,33,35 SEE POWER PLAN NOTE #15 60A -3P 35AF EXISTING 200 AMP, 277/480 VOLT, ELECTRIC SERVICE FROM MALL ELECTRICAL ROOM. PANEL "LA "; SEE SCHEDULE THIS SHEET 4,394 aic *4 4,551 aic PANEL "LB "; SEE SCHEDULE THIS SHEET *5 4,289 aic LIGHTING RELAY PANEL; SEE SCHEDULE THIS SHEET 32 #10 AWG PHASE /NEUTRAL 2 #10 AWG GROUND 2" CONDUIT E -2 4 #1 /0 AWG PHASE /NEUTRAL 1 #6 AWG GROUND 2" CONDUIT Power Riser Diagram NOT TO SCALE RISER DIAGRAM NOTES: 4 #4 AWG PHASE /NEUTRAL 1 #10 AWG GROUND 1 1/4" CONDUIT 1. ELECTRICAL CONTRACTOR TO BALANCE LOAD AS CLOSE AS POSSIBLE, MAX. 10% IMBALANCE BETWEEN PHASES. CONTRACTOR SHALL FURNISH AND INSTALL ALL BREAKERS AS REQUIRED FOR NEW INSTALLATION. 2. E.C. SHALL VERIFY AND COORDINATE ELECTRICAL SYSTEM COMPONENTS AND CAPACITY WITHIN TENANT SPACE PRIOR TO BID. E.C. SHALL VERIFY THAT ALL EQUIPMENT IS IN GOOD WORKING ORDER AND WILL MEET ALL GOVERNING CODES. ANY DISCREPANCIES SHALL BE IMMEDIATELY BROUGHT TO THE TENANTS ATTENTION. 3. E.C. SHALL PROVIDE NEW EQUIPMENT AS REQUIRED TO MEET LANDLORD AND TENANT DESIGN SPECIFICATIONS. 4. FAULT CURRENT CALCULATIONS BASED UPON THE FOLLOWING INFORMATION: 200 AMP FEEDER TO SPACE BY LANDLORD IS #3/0 COPPER THHN IN STEEL EMT RUN FOR 100 FEET. ASSUMING 100,000 aic AT LANDLORD'S SWITCHGEAR. *1 *2 *3 *4 *5 60 AMP FEEDER TO TRANSFORMER IS BASED UPON 20' OF THHN IN STEEL EMT. 45kVA TRANSFORMER BASED UPON 2.5% IMPEDANCE. 150 AMP TRANSFORMER SECONDARY IS BASED UPON 20' OF #1/0 COPPER THHN IN STEEL EMT. 60 AMP FEEDER TO PANEL "LB" IS BASED UPON 20' OF #4 COPPER THHN IN STEEL EMT. 74" AFF; SEE POWER PLAN NOTE #3 FIRE ALARM SYSTEM SHALL BE DESIGNED AND INSTALLED BY LANDLORD'S CONTRACTOR AT TENANT'S EXPENSE. GRX RS232 INTERFACE SEE DIAGRAM ON DWG E -1. -71 n L. 41 ir NOTE: ELECTRICAL CONTRACTOR TO VERIFY EXACT LOCATION OF ALL DEVICES BEING INSTALLED BEHIND FIXTURES TO ENSURE THAT DEVICES ARE LOCATED AT CUTOUTS IN BACK OF FIXTURE. FIRE ALARM WORK TO BE PERFORMED UNDER SEPARATE PERMIT. ENGINEERED DRAWINGS TO BE SUBMITTED SEPARATELY. 1 Power Plan Notes: 1. COORDINATE MOUNTING HEIGHT IN THE FIELD PRIOR TO CONSTRUCTION. 2. THE CONDUITS FOR TEMPERATURE CONTROLS TO BE PROVIDED BY THE ELECTRICAL CONTRACTOR. 3. OUTLETS BEHIND PLASMA DISPLAY IN THE DEMO ROOM AND LOUNGE SHALL BE CLOCK TYPE, MOUNTED 74" AFF. 4. OUTLETS BEHIND PLASMA DISPLAY IN THE RESTAURANT ROOM SHALL BE CLOCK TYPE, MOUNTED 68" AFF. 5. PROVIDE AND INSTALL SIX (6) FEET OF WIREMOLD #2000 OR APPROVED EQUAL WIREMOLD WITH NEMA 5 -15R RECEPTACLES 6" OC. MOUNT AT 48" AFF (UNLESS OTHERWISE NOTED) AT STOCKROOM FIXTURE. 6. HARD DECK ON THIS PROJECT IS 17' -6" ABOVE FINISHED FLOOR. ANY SUSPENDED EQUIPMENT SHALL BE PROPERLY SUPPORTED WITH THIS IN MIND. 7. RESERVED. 8. JUNCTION BOX FLUSH MOUNTED FOR STORE FRONT SIGN. SEE ARCH. DRAWINGS FOR ADDITIONAL INFORMATION. VERIFY LOCATION WITH SIGN INSTALLER. 9. SEE SPECIFICATIONS FOR DOORBELL SYSTEM REQUIREMENTS. 10. A CLEARANCE OF 36" MUST BE MAINTAINED IN FRONT OF ALL ELECTRICAL PANELS AT ALL TIMES. 11. RESERVED. 12. RESERVED. 13. VERIFY EXACT FIELD LOCATIONS ALONG WITH ACTUAL POWER REQUIREMENTS FOR HVAC UNIT PRIOR TO PURCHASING AND INSTALLING ANY ELECTRICAL EQUIPMENT. 14. OBTAIN HVAC EQUIPMENT DATA SHEETS. VERIFY POWER REQUIREMENTS. IF POWER 15 INSUFFICIENT, NOTIFY ARCHITECT IMMEDIATELY, PRIOR TO ROUGH -IN. 15. SIZE FUSES PER HVAC MANUFACTURERS REQUIREMENTS. g� General Notes: E -2 / 1-5)Symbol Legend: 2 © 125 VOLT, 2 POLE, 3 WIRE, 20 AMP., DUPLEX RECEPTACLE. "2" DENOTES CIRCUIT NUMBER. 2e- 0 h--- W ----1 Sa SLv1 SD 0 AFF GF WP SP 0 12 14 LA 125 VOLT, 2 POLE, 3 WIRE, 20 AMP., SIMPLEX RECEPTACLE. "2" DENOTES CIRCUIT NUMBER. 125 VOLT, 2 POLE, 3 WIRE, 20 AMP., DUPLEX RECEPTACLES, DOUBLE DUPLEX. 125 VOLT, 2 POLE, 3 WIRE, 20 AMP., DUPLEX MOUNTED ABOVE COUNTER. 125 VOLT, 2 POLE, 3 WIRE, 20 AMP., DUPLEX RECEPTACLE. EQUIPPED WITH INTEGRAL GROUND FAULT CIRCUIT INTERRUPTER. 125 VOLT, 2 POLE, 3 WIRE, 20 AMP., DUPLEX CEILING RECEPTACLE. 125 VOLT, 2 POLE, 3 WIRE, 20 AMP., DUPLEX FLUSH, FLOOR RECEPTACLE. SEE SPECIFICATIONS. WIREMOLD WITH RECEPTACLE AS NOTED SINGLE POLE TOGGLE SWITCH SUBSCRIPT DENOTES FIXTURE CONTROLLED LUTRON LOW VOLTAGE SWITCHING STATION. SEE SPECIFICATIONS. DIMMER SWITCH LUTRON NT -600, RATING AS REQUIRED, PROVIDED BY ELECTRICAL CONTRACTOR DENOTES NEW WIRING OR DEVICES DENOTES EXISTING WIRING OR DEVICES LUTRON FEED THROUGH, RELAY TYPE CONTROL PANEL 120Y/208 VOLT, 3 PHASE PANELBOARD JUNCTION AND /OR PULL BOX. SERVICE SWITCH, 20 AMP, 125 VOLT DISCONNECT SWITCH, UNFUSED. DISCONNECT SWITCH, FUSED. ABOVE FINISHED FLOOR TO CENTERLINE OF DEVICE (UNLESS OTHERWISE NOTED) GROUND FAULT CIRCUIT INTERRUPTER WEATHERPROOF TRANSIENT VOLTAGE SURGE SUPPRESSER LUTRON LOW VOLTAGE OCCUPANCY SENSOR, CEILING MOUNTED. SEE SPECIFICATIONS. DOOR BUZZER SYSTEM PUSHBUTTON DOOR BUZZER & TRANSFORMER HOMERUN TO PANEL "LA" FOR CIRCUIT #'s 12 & 14. EACH 120 VOLT CIRCUIT SHALL HAVE IT'S OWN NEUTRAL, NO NETWORKS. HOMERUN TO PANEL "LA" FOR 3 PHASE LA -2,4,6 EQUIPMENT. PROVIDE 3 POLE BREAKER PER SCHEDULE. 1. THE CONTRACTOR SHALL VERIFY EXACT LOCATION OF ALL OUTLETS IN THE FIELD. 2. LOW VOLTAGE WIRING, TEMPERATURE CONTROLS AND THERMOSTAT WIRING MAY BE RUN EXPOSED. ALL EXPOSED CABLE RUNS IN THE CEILING SPACE SHALL BE TYPE FPLP (FIRE RATED PLENUM CABLE) IN ACCORDANCE WITH ARTICLE 760 OF THE NATIONAL ELECTRICAL CODE. ALL CABLES SHOULD BE NEATLY TIED TO STRUCTURE ABOVE. 3. PROVIDE AND INSTALL PLASTER RINGS ON ALL FLUSH OUTLETS, SWITCH AND FIXTURE BOXES. 4. ALL ELECTRICAL WIRING SHALL BE IN CONDUIT (EMT). MC CABLE PERMITTED ONLY WHERE °CONCEALED AND APPROVED BY CODE. 5. SEE DRAWING E -1 FOR SPECIFICATIONS AND MOUNTING HEIGHTS. 6. PROVIDE AND INSTALL ONE GREEN # 6 AWG COPPER GROUNDING CONDUCTOR IN 1/2" CONDUIT TO BUILDING STEEL AND CLAMP WITH BRONZE GROUND CLAMP FOR TELEPHONE TERMINAL BOARD. 7. LOW VOLTAGE WIRING (TELEPHONE, DATA, DOOR BUZZER, ETC.) IS PERMITTED TO BE INSTALLED AS PLENUM RATED CABLE, ONLY WHERE PROPERLY SUPPORTED. TYPE NM CABLE IS NOT PERMITTED. 8. ELECTRICAL CONTRACTOR SHALL INSPECT ANY AND ALL ELECTRICAL WORK BY LANDLORD IN ACCORDANCE WITH ALL APPLICABLE CODES AND LOCAL WIRE INSPECTOR AND BE RESPONSIBLE FOR FINAL INSTALLATION WIRING ETC. 9. ALL RECEPTACLES SHALL BE MOUNTED AT 18 "AFF UNLESS OTHERWISE NOTED. 10. ALL PANELBOARD CIRCUIT BREAKERS SHALL BE SWITCH DUTY RATED. ADDITIONALLY, 2 AND 3 POLE BREAKERS SHALL BE HACR RATED AS WELL. 11. ALL CONDUIT AND FLEXIBLE CONDUIT SYSTEMS SHALL HAVE A SEPARATE EQUIPMENT GROUNDING CONDUCTOR. 12. THE SPACE ABOVE THE DROPPED CEILINGS IS BEING USE AS A RETURN AIR PLENUM. ALL WIRING ABOVE DROPPED CEILINGS SHALL BE PLENUM RATED. 13. ALL WIRING SHALL BE COPPER, # 12 AWG MINIMUM. NON - METALLIC SHEATHED CABLE SHALL NOT BE USED. 14. ALL FIRE ALARM WIRING SHALL BE INSTALLED IN CONDUIT (BY OTHERS). 2005 NEC SERVICE SIZE CALCULATIONS DESCRIPTION CONNECTED ARTICLE DEMAND % DEMAND GENERAL LIGHTING LOAD 6570 220.42 100.00% 6570 OTHER LIGHTING LOAD 810 220.43 100.00% 810 TOTAL LIGHTING LOAD 7380 220.20A 125.00% 9225 RECEPTACLE LOADC 1 OKVA 7220 220.44 100.00% 7200 RECEPTACLE LOAD710KVA 0 220.44 50.00% 0 MULTI-OUTLET ASSLY. 1440 220.14H 100.00% 1440 CONTINUOUS RECEPTACLE LOAD 720 220.14L 125.00% 1440 SPECIAL LOADS 6400 220.10 100.00% 6400 HEATING OR AIR COND. 10000 220"60 100.00% 10000 MOTOR LOADS 1260 220"50 100.00% 1261 LARGEST MOTOR 1260 430.24 25.00% 315 TOTALS VA: 36,456 B KVA: 37 1 MIN. AMPS © 480 VOLTS: 44 LTG: DEMO ROOM SERVICE SIZE (AMPS) W/25% SPARE CAPACITY: 55 * 1 1 0 Net W1► �MNCOOCO �W c c ,... 0 4.0404 �mm 3170 u, u) o X 1-0 REVIEWED Co MPLIN NFPA 70 - NEC MAR 2 6 2008 City Of Tukwila B I .PNG DM ION PANEL LA 120/208 VOLTS, 3 0, 4 W, 150A ❑ MLO ® MCB ® SOLID NEUTRAL ® GROUND BUS SC RATING: 10 kA MOUNTING: ® SURFACE ❑ FLUSH NEMA 1 ENCLOSURE DESCRIPTION LOAD kVA CIRCUIT BREAKER PHASE CIRCUIT BREAKER LOAD kVA DESCRIPTION TRIP POLE NO. NO. TRIP POLE LTG: MAIN STORE .48 20 1 1 A 2 20 1 0 SPARE LTG: CONSULT & EXAM RMS .68 20 1 3 B 4 20 1 "18 RCPT: SHOW WINDOW LTG: FUTURE "10 20 1 5 C 6 20 1 .18 RCPT: SHOW WINDOW LTG: REST. SIM. RM .35 20 1 7 A 8 20 1 .72 RCPT: GENERAL LTG: LOUNGE .33 20 1 9 B 10 20 1 .36 RCPT: REST. SIM. RM LTG: DEMO ROOM .73 20 1 11 C 12 20 1 .18 RCPT: CASHWRAP (IG) LTG: OFFICE, BRK RM, TOILET .44 20 1 13 A 14 20 1 .54 RCPT: CASHWRAP LTG: STRFRNT SIGN VIA TC 1.2 20 1 15 B 16 20 1 .54 RCPT: LOUNGE LTG: MERCHANDISE DISPLAYS 1.25 20 1 17 C 18 20 1 .36 RCPT: TELE /DATA (IG) LTG: STOREFRONT .24 20 1 19 A 20 20 1 .54 RCPT: DEMO ROOM SURGE SUPPRESSOR .24 30 3 21 B 22 20 1 .90 RCPT: GENERAL 23 C 24 20 1 .18 RCPT: BREAKROOM COUNTERTOP 25 A 26 20 1 0 SPARE REFRIGERATOR 1.2 20 1 27 B 28 20 1 1.4 PLUGMOLD WATER COOLER .60 15 1 29 C 30 20 1 1.5 WATER HEATER DUCT HEATER 10.0 35 3 31 A 32 20 1 0 SPARE 33 B 34 20 1 0 SPARE 35 C 36 60 3 1.15 1.62 1.42 PANEL LB LTG: EMERG. LTS, EXITS .3 20 1 37 A 38 SPARE 0 20 1 39 B 40 SPARE 0 30 1 41 C 42 25 1 1.7 VAV FAN (3/4 HP) 8.65kVA + 11.6kVA + 11.3kVA = 31.6 kVA - 87.8A AO= 72.OA, B0= 96.8A, CO= 94.5A SCHEDULE NOTES: BREAKER TO BE PROVIDED WITH HANDLE LOCK. DIRECTORY FOR EACH PANELBOARD. 1. " *" DENOTES PROVIDE CIRCUIT 2. PROVIDE NEW TYPED CIRCUIT PANEL LB 120/208 VOLTS, 3 0, 4 W, 60A ® MLO ❑ MCB ® SOLID NEUTRAL ® GROUND BUS SC RATING: 10 kA MOUNTING: IA SURFACE ❑ FLUSH NEMA 1 ENCLOSURE DESCRIPTION LOAD kVA CIRCUIT BREAKER PHASE cur BREAK LOAD kVA DESCRIPTION TRIP POLE NO. NO. TRIP POLE RCPT: AUDIO EXAM RM 3 .54 20 1 1 A 2 20 1 "25 RCPT: KIOSK RCPT: AUDIO EXAM RM 2 .54 20 1 3 B 4 20 1 .54 RCPT: TELE /DATA RCPT: AUDIO EXAM RM 1 .54 20 1 5 C 6 20 1 "7 RCPT: DISPLAY RCPT: OFFICE .36 20 1 7 A 8 20 1 0 SPARE RCPT: CONSULT ROOM .54 20 1 9 B 10 20 1 0 SPARE RCPT: TOILET .18 20 1 11 C 12 20 1 0 SPARE SPARE 0 20 1 13 A 14 20 1 0 SPARE SPARE 0 20 1 15 B 16 20 1 0 SPARE SPARE 0 20 1 17 C 18 20 1 0 SPARE BUSSED SPACE - - - 19 A 20 - BUSSED SPACE BUSSED SPACE _ - - 21 B 22 - BUSSED SPACE BUSSED SPACE - - - 23 C 24 - --- - BUSSED SPACE 1.15kVA + 1.62kVA + 1.42kVA = 4.19kVA = 12A A0= 9.6A, B0= 13.5A, C0= 11.8A SCHEDULE NOTES: BREAKER TO BE PROVIDED WITH HANDLE LOCK. 1. " *" DENOTES PROVIDE CIRCUIT CO 09<14 * * * * * JOB NO: ZO 1I -Oi -I STORE NO: 1000 DRAWN BY: WSJ CHECKED: -lGG PROJECT COORDINATION: ®® Tel: 781 - 331 -4000 C 0 0 Fax: 781 - 335 -2115 Southcenter CO N -I J -I--a 0 0) CT) i L 0 REVISIONS: RECEP'ED MAR 0 4 2008 PERMIT CENTEh-? SHEET NUMBER E -2 SHEET 18 OF 18