Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL08-0220 - WESTFIELD SOUTHCENTER MALL - THAI GO NOODLE ZONE
THAI GO NOODLE ZONE 2600 SC MALL FC 15 08-06-08 ELO8-220 City f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 6364200010 Address: 2600 SOUTHCENTER MALL TUKW Suite No: Permit Number: EL08 -220 Issue Date: 05/06/2008 Permit Expires On: 11/02/2008 Tenant: Name: THAI GO NOODLE ZONE Address: 2600 SOUTHCENETR MALL FC -15 , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: THOMAS LI Phone: 253 - 973 -8500 Address: 16022 12TH AVE SW , BURIEN WA Contractor: Name: BEST ELECTRIC CORP Address: 14027 69 AV SE , SNOHOMISH WA Contractor License No: BESTEC *070M7 Phone: 206 679 -7617 Expiration Date: 08/04/2009 DESCRIPTION OF WORK: INSTALL ONE ELECTRICAL PANEL (200A, 3 PHASE, 120/208V), RECEPTACLES, AND LIGHTS Value of Electrical: $10,000.00 Type of Fire Protection: Fees Collected: National Electrical Code Edition: Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: AV2 $307.50 2005 Date: I lAX I A I hereby certify that I have read and a an 'ned this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit. Signature: Date: CP Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -220 Printed: 05 -06 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 2600 SOUTHCENTER MALL TUKW THAI GO NOODLE ZONE Permit Number: Status: Applied Date: Issue Date: EL08 -220 ISSUED 03/05/2008 05/06/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be m accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change m the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: Date: doc: Cond -Elec EL08 -220 Printed: 05 -06 -2008 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 httn://www.ci.tukwila.wa.us SITE LOCATION Site Address: Tenant Name: Property Owners Name: Mailing Address: Electrical Permit No. E L-0' - Or -O Project No. For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: (193(p 1 0 Suite Numbed "7 F or: New Tenant: IV Yes ❑ ..No �r -_ 01 City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be Mailing Address: e, Day Telephone: 7 3 /ei L-/ � Cl�" /k City �o S ate E -Mail Address: ' � /yj F Fax Number 214 ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): "'— Scope of Work (please provide detailed information): Will service be altered? Type of Use: Type of w tic: New • Low Voltage Property Served by: ❑ P t Sound Energy Seattle City Light ❑ Yes ❑ No ❑ A• ddition ❑ G• enerator ❑ Service Change ❑ Fire Alarm H: W pplications\Forms- Applications On Line\4 -2007 - Electrical Permit Application.doc bh Adding more than 50 amps? ❑ Yes ❑ No ❑ Remodel ]Tenant Improvement ❑ Telecommunication ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings (including an attached garage) ❑ Garages, pools, spas and outbuildings ❑ Low voltage systems (alarm, furnace thermostat) $140.00 $75.00 ea $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Nam ■ Mailing Address: IDate Application Accepted: Date: Day Telephone: City State Zip 1 Date Application Expires: 9.. S .� s Staff Initials: H:Wpplications \Forms - Applications On Line \4-2007 - Electrical Permit Application.doc bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -220 Address: 2600 SOUTHCENTER MALL TUICW Status: APPROVED Suite No: Applied Date: 03/05/2008 Applicant: THAI GO NOODLE ZONE Issue Date: Receipt No.: R08 -01494 Initials: JEM User ID: 1165 Payment Amount: $360.00 Payment Date: 05/06/2008 10:14 AM Balance: $0.00 Payee: WEST COAST PROPERTY MAINTENANCE TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3001 360.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 360.00 Total: $360.00 2062 05/06 9711 TOTAL 360.00 doc: Receiot -06 Printed: 05 -06 -2008 • City of Tukwila • Department of Community Deveiopment 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -220 Address: 2600 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 03/05/2008 Applicant: THAI GO Issue Date: Receipt No.: R08 -00633 Payment Amount: $307.50 Initials: WER Payment Date: 03/05/2008 02:38 PM User ID: 1655 Balance: $0.00 Payee: RACHA THAI TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1028 307.50 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES 000.322.101.00.0 246.00 000.345.832.00.0 61.50 Total: $307.50 doe: Receiot -06 Printed: 03 -05 -2008 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Y' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: 7 14'Prt CIO Type of Inspection: Z/00 Address: ?-6oO Date Called: Special Instructions: 1 Date Wanted: WO b 6...m.. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 04 /ic,A) Inspector: 667vAkis Date: 0,8/04,M ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit &d - PERMIT NO. (206)431 -3 7 Project: , A Mt A l O Type of Inspection: (00 - 4- re.,to-P Mc- c, SE- -145' PebP rogil7 Address: nO0 Date Called: I ;GP f Pti R.001 ----- P e t_ ,._.` Special Instructions: Date Wanted: 2�( p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: (11 ii . V —549 Pa' rt. Cotij - 4- re.,to-P Mc- c, SE- -145' PebP rogil7 -SP Ic.(U 5 - LA set..- DJ Pa•Jt- lb 0\1 rk t (Aire I ;GP f Pti R.001 ----- P e t_ ,._.` - L kt3t -5 o'J e,o0Prze pt r m INDIcpre pri.. - %5- mcLohr.J■LAil arrit CO C-9 Kf GAM./ 1.4 Inspector: 66402,4 Date: 07 (21 to El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: T A/ 2 it4 bI e' Type of Inspection: 7 A dry so Sc Nii9 f, vG Date Called: Special Instructions: Date Wanted: 6 //g... m • Requester: Phone No: proved per applicable codes. Corrections required prior to approval. COMMENTS: 1/4 r.2 /C F/7r -- /AK/ MM bola- s Inspect J /`. / , G / AtMAU6 Date: $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: f INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit Car-no PERMIT NO. (206)431 -3670 Project :� / Type of Inspection: Address: mk, Date Called: 700 Z--- Special Instructions: Co t/'L`1Z-. aeildk5 Date Wanted: a.m. Lit Requester: Phone No: unite 61.. Approved per applicable codes. Corrections required prior to approval. COMMENTS: i looJ D.K. ' Co t/'L`1Z-. aeildk5 — D_K- - unite 61.. o56 7001 Q.i< . - t5reMlle( 1002- CI.o Lit Inspector: ..1■;7 13fAC-g„ Date: 614 ,A3 I ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: ar Adi t% L. - — '' %... ..- _._a._.�..._...._ ... .s..•` ..,e.4`...i__ - A: • • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -220 DATE: 03 -05 -08 PROJECT NAME: THAI GO NOODLE ZONE SITE ADDRESS: 2600 SOUTHCENTER MALL FC -15 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTME�N6TS. 34{kt Division Public Works ❑ Fire Prevention Structural n Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 03-06-08 Complete Incomplete Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUESITHURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04 -03 -08 Approved ❑ Approved with Conditions I Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing sltp.doe 2.28.02 Look Up a Contractor, Elect Electrion or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License BESTEC *070M7 Licensee Name BEST ELECTRIC CORP Licensee Type ELECTRICAL CONTRACTOR UBI 601480887 Ind. Ins. Account Id Business Type CORPORATION Address 1 14027 69TH AVE SE Address 2 City SNOHOMISH County SNOHOMISH State WA Zip 98290 Phone 2066797617 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 7/27/1993 Expiration Date 8/4/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License LEE * *S *973DS Master Electrician Information License LEE * *S *973DS Name LEE, SAM Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date LEE, SAM 01/01/1980 Bond Information No Matching Information 1 Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= BESTEC *070M7 05/06/2008 FILE Penult No. Tan review approval le seitict . Approval of construction dounerds des not aulksize the vb3lathrt of any *Wed code orot . Cbcelpl of Raid ccov and condign is acknowledged: LEASE LINE HOOD EIaAsURE 6 -9' AFF• 75W (1)b% CLASS 1 HOOD 6' -9" A.F. BY OTHER 75W NOTE: 2006 IBC - Sec. 1006 Provide an average of one foot - candle illumination at the floor along the entire egress pathway and exit discharge FLOATING LIGHT TROUGH 7'--6" A.F.F. )) 75W SUSPENDED CYO COLIC s-pr Hr:n' -875• A.F.F HOOD EHCL95URE 6 -9• AF.F. KEF FUSE DISCONNECT SWITCH \ / SWITCH (TYP.) �# 12 THHN (TYP.)� (TYP.) STARTER 120V CONTROL (TYP.) LOCATION BY INSTALLER N F 3P 20 MAU F 3P 20 GAS VALVE INDICATING LITS T.O. PARTITION © 3'8" 16" SNEEZE GUARD (TOTAL HEIGHT 5' A.F.F) COUNTER HEIGHT 36" PAPER TOWEL DISPENSER SOAP DISPENSER PLATE STORAGE BELOW DROP IN RICE WARMER THAI GO DROP IN PREP SINK UNDER COUNTER WATER HEATER PLANTER FOOD WARMER 18" SNEEZE GUARD COUNTER HEIGHT 34" FOOD WARMER 1 CCUNTER HEIGHT 34• AFF. PO POS 15 -1 ■ f i ICE M PLATFORM DINING AREA BY MALL DIGITAL MENU DROP IN COLD PAN THAI GO, NOODLE ZONE LANG PLAN SCALE 1/4 = 1' -0" PANEL "EP" SHUNT TRIPS 1/2"C TYP. 2224,26 29/ 73 28,30,32 2N 3 PANEL EP FIRE SUPPRESS, PANEL E36 HOOD EXHAUST SYSTEM INTERLOCK WIRING DIAGRAM ANSUL KITCHEN HOOD FIRE SUPRESSION CONTROL PANEL INSPECT PANEL AND DETERMINE PRECISE WIRING TERMINATIONS, REQUIPMENTS AND ALARM OPERATION. FIRE ALARM WIRING FOR MONITORING VOLTAGE -FREE ALARM CONTACTS 120VAC CONTROL POWER (E36) /0-x%) M 120VAC OUT TO HOLD NORMALLY- CLOSED GAS VALVE OPEN VALVE CLOSES UPON ALARM CONDITION. 120VAC OUT TO SHUNT - TRIP COIL IN PANEL TO TRIP CIRCUIT BREAKERS UPON ALARM AND DE-ENERGIZE APPLIANCES LOCATED BELOW KITCHEN HOODS, PROVIDE CONNECTIONS TO ALL ASSOCIATED SHUNT - TRIP BREAKER COILS. SHUNT - TRIP BREAKER (TYP) KITCHEN HOOD FIRE SUPRESSION (TYPICAL) COWER HUGH! 34• AFF. RECESSED CUP ACCESS COWS HEIGHT UMW!. NOODLE ZONE COUNTER HEDif 34• AFF. PASS - THROUGH COUNTER DROP IN COLD PAN EQUIPFV EST LIST BY Dale, Tub DIVISION THAI GO, NOODLE ZONE POWER PLAN SCALE 1/4 = 1' -0" PANEL SCHEDULE "EP" SUPPLIER = Cc DESCRIPTION MANUFACTURER MODEL NUMBER ELECTRI UILDIN1 ITEV NO. c3 (_n C_.6 Li O OTHERS LOAD U < dH VOLTS PHASE (__) 1 ►-4 LOCATION (168A) 2 1 FOOD WARMER ATLAS METAL WIH -57, WIH -37 CUSTOM TOP 2.55 10.6 200 240 HALOGEN 11 2 ! 4 4 800 2 SANDWICH COOLER TRUE TPP -93 30.9 CUBIC FT. CAPACITY 9.7 HOOD LIGHT 120 1 DCO 3 ►■ 6 1 SANDWICH COOLER BEVERAGE -AIR SP60 17.1 CUBIC FT. CAPACITY M 6.5 #3 v 115 1 DCO 4 10.-.41 2 RICE WARMER WELLBON (WRS- 1100S) M K UNDERCOUNTER REFRIGERATOR 13 120 7 5 ® 10 1 RICE COOKER RICEMASTER RM -55N K v Q 1000 9 6 ►. 12 1 WOK 8'x41" IMPERIAL (CUSTOM) K SODA MACHINE CI 300 11 11 7 ® 14 300 1 GAS RANGE AMERICAN RANGE AR -6 p6.52 1200 13 20 �, 8 CC 600 FUTURE SPARE EQUIPMENT 1 FRYER VULCAN 1GR45 1300 15 I „ 9 1,--11 K 1 PASTA COOKER ELECTROLUX 200372 17 7.7 208 3 JBOX 10 CCI K 1 WOK RANGE 35 "X39 ") IMPERIAL (,CUSTOM) �, 20 22 1000 11 PP- -11 K 1 ICE MAKER (31 "X30 "X 57.5 ") ICEOMATIC 0400 14.4 I 115 1000 KEF (3HP)* 12 !■ RICE WARMER #1 Q 300 2 HAND SINK KROWNE 28 -1419 I 26 1000 M 13 ' ' ■ 300 25 1 UNDERCOUNTER REFRIGERATOR TUC -119 43.9 CUBIC FT. CAPACITY 20 12.0 1000 115 1 K 14 ►' 27 1 1 COMP PREP SINK ADVANCE DI -1- -2012 30 1000 MAU (3HP)* M K SANDWICH COOLER # 2 Q 15 ►► 1 MOP SINK ADVANCE 9 -OP -20 1000 M K SANDWICH COOLER # 3 \l, 1200 16 ►.A � 1 HAND SINK ADVANCE DI -1 -25 *MICRO WAVE K M *HOT WATER HTR 23 2250 33 17 10,--4 1 3 COMPARTMENT SINK (20 "X16 "X12 ") ADVANCE DI -3 -1612 M M 2250 35 18 10-■ 38 1 UNDER COUNTER REFRIGERATOR TUC -67 20.6 CUBIC FT. CAPACITY K 5.1 1/5 115 1 I 19 CCI 40 1500 3 POS RADIENT SYSTEMS P1220 *DIGITAL MENU BOARD 300 39 I 20 C Z:1 1500 SIGNAGE* 1 SODA MACHINE LANCER 2300 SABRE TOWER v 2.4 41 115 1 21 110-411 2 ICE BIN DRINK DISPLAY ATLAS METAL, CUSTOM I 22 CCI 1 PREP AREA CUSTOM 23 t•■ 1 WATER HEATER (ELECTRIC) PATRIOT PCE 50 2OLSA 50 GALLON CAPACITY 4.5 208 24 ■■ 1 FOOD WARMER ATLAS METAL WIH -57, CUSTOM TOP 4.25 17.7 240 25 10.- Ai 3 PAPER TOWEL DISPENSER BOBRICK B -2621 26 ►► 3 SOAP DISPENSER BOBRICK B -2111 27 ►► SPARE NUMBER 28 ■■ SPARE NUMBER 29 ►■ SPARE NUMBER 30 !■ SPARE NUMBER 31 !► SPARE NUMBER 32 ►■ SPARE NUMBER 33 CC SPARE NUMBER 34 01.-41 SPARE NUMBER 35 CCI SPARE NUMBER THAI GO, NOODLE ZONE POWER PLAN SCALE 1/4 = 1' -0" PANEL SCHEDULE "EP" VOLTAGE: Z120/2O8V., 3 PHASE. 4WIRE..._._❑ 208V., 3 PHASE, 3 WIRE 277/480V., 3 PHASE, 4WIRE 480V., 3PHASE, 3 WARE MOUNTING: 2/FLUSH SURFACE MAIN: LUGS ONLY AMP. TOP n MAIN BREAKER 200 AMP. BOTTOM NEUTRAL 50% 7-100% COVER DOOR WITH LOCK DOOR WITHOUT LOCK ALL BREAKERS 20 AMP. 1 POLE UNLESS NOTED OTHERWISE U/L LISTED BREAKER INTERRUPTING CAPACITY : 12000 MS SYM. AMPS. CONNECTED LOAD_ PHASE A 14,575 W., PHASE B: 14,375 W., PHASE C., 11,724 W., TOTAL 39,674 WATTS (110A) LOCATION LOAD NO. 40W ABC IT1 T1 NO. LOAD LOCATION (168A) 2 1650 ICE MAKER 11 K M CASH REGISTOR #1 (POS) ® 200 1 HALOGEN 11 0 R1 4 800 PASTA COOKER* ® K M #2 HOOD LIGHT 200 3 75W ,1 6 800 K M v #3 v 200 5 8 800 GENERAL PURPOSE M K UNDERCOUNTER REFRIGERATOR 13 1500 7 11 10 SPARE K v Q 1000 9 12 474 UTS (R1 /P1 /TFI) L K SODA MACHINE CI 300 11 11 14 300 LITS (HOOD) (H1) L L HEAT LAMP 1200 13 20 �, �- 16 600 FUTURE SPARE EQUIPMENT K K FOOD WARMER 1300 15 I „ 18 1000 K K 1300 17 20 SPARE K FOOD WARMER 24 2125 19 �, 20 22 1000 M K 2125 21 • I 24 1000 KEF (3HP)* M K RICE WARMER #1 Q 300 23 I 26 1000 M K RICE WARMER #2 Q 300 25 � 20 28 1000 M K SANDWICH COOLER # 1 Q 800 27 �i I 30 1000 MAU (3HP)* M K SANDWICH COOLER # 2 Q 1200 29 I 32 1000 M K SANDWICH COOLER # 3 \l, 1200 31 30 � 34 1500 *MICRO WAVE K M *HOT WATER HTR 23 2250 33 I �' 36 100 HOOD FIRE SUP SYSTEM M M 2250 35 11 38 200 RECEPTACLE@ROOF M K *MICRO WAVE 1500 37 h, 40 1500 SIGNAGE* L L *DIGITAL MENU BOARD 300 39 „ 42 1500 SIGNAGE* L L v 380 41 *FIELD VERIFIED BY INSTALLER LOAD SUMMARY MIS LIGHT1NG KITCHEN TOTAL LOAD AMPARES CONNECTED LOAD 12 800 5,574 • S °7a ofl i i2GIST /'oTm, CODE FACTOR 100% 125% COMPUTER LOAD 12,800 6,967 21,300 39,674 757 65% 13,845 33;61 -2 110A REFERENCES TO 2005 NATIONAL ELECTRICAL CODE LIGHTING FIXTURE SCHEDULE SYMBOL SYM NO. NO. FIXTURE QTY. QTY. MANUFACTURE MODEL NO. WATTS LAMP 0 :1 TF1 RECESSED TRACK FIXTURE 2 40W IT1 T1 RECESSED TRACK LIGHT (6') 1 CAL LIGHTING 2400W HALOGEN P1 PENDANT LIGHT 2 RESOLUTE BEN Y 37W HALOGEN 0 R1 RECESSED DOWN LIGHT WITH GLASS SHEILD 8 CONTRAST LIGHTING T3500D /SM 40W HALOGEN H1 HOOD LIGHT 4 75W SPECIAL NOTES 1. J -BOX FOR CONNECTION TO HOOD SUPPRESSION SYSTEM. PROVIDE CONDUIT AND INTERLOCK WIRING FOR SHUNT TRIP TYPE CIRCUIT BREAKER TO AU_ CIRCUITS SERVING EQUIPMENT UNDER THE KITCHEN HOOD. PROVIDE LOW VOLTAGE WIRING TO INTERFACE FIRE SUPPRESSION SYSTEM WITH THE EXISTING FIRE ALARM SYSTEM. COORDINATE WORK WITH EQUIPMENT SUPPLIER AND SOUTHCENTER MALL FACILIIES FOR LOCATIONS AND REQUIREMENTS. 2, TENANT SHAD_ PROVIDE NORMALLY OPEN AND CLOSED CONTACTS OF KITCHEN EXHAUST FIRE EXIINGGUISHING SYSTEMS TO PROVIDE ALARM SIGNAL FOR BASE BUIUNG FIRE ALARAM SYSTEM. TENANT SHALL EXTEND WIRING IN CONDUIT TO APPROPRIATE FIRE ALARM ZONE PANEL AND DIRECTLY EMPLOY LANDLORD DESIGNATED CONTRACTOR TO MAKE FINAL CONNECTIONS. ALL COMPONENTS MUST BE COMPATIBLE WITH BASE BUILDING SYSTEM. COORDINATE WITH LANDLORD'S FIELD REPRESENTATIVE PRIOP TO THE START OF CONSTUCTION_ 3. PRIOR TO MAKING ANY PIPE OR DUCT ROOF PENETRATION OR CORE DRILL AND OR POSITIONING OF ANY EQUIPMENT ON THE ROOF, AU_ THE PROPOSED LOCATIONS AND /OR PENETRATIONS SHALL MATCH LOCATIONS AS INDICATED ON LANDLORD - APPROVED PLANS AND APPROVED BY LANDLORD'S CONSTRUCTION FIELD COORDINATOR. 4. TENANTS GENERAL CONTRACTOR SHALL PROVIDE A FIRE WATCH AND PORTABLE FIRE EXTINGUISHER (MINIMUM SIZE 2k 20BC), WHEREVER ANY WELDING IS DONE WITH THE DEMISED PREMISED. THE PERSON PERFORMING THE FIRE WATCH SHALL REMAIN IN THE TENANT SPACE FOR AT LEAST ON (1) HOUR AFTER THE COMPLETION OF ANY WELDING. THIS SHALL BE COORDINATED THROUGH THE CITY OF TUKWILA FIRE DEPARTMENT. ELECTRICAL CONTRACTOR TO VERIFY ALL SERVICE EQUIPMENT SIZE AND LOCATION "EP ",200A- 120/208V 3 PHASE, 4W,42CKS 2' 0.0 W/PULL WIRE BY LANDLORD TENANTS CONTRACTOR TO PULL -IN 41/3/0 THHN CU 1#6GROUND. ELECTRICAL CONTRACTOR SHALL FURNISH AND PULL REQUIRED WIRING IN EMPTY CONDUIT PROVIDED BY LANDLORD TO A SPECIFIED LOCATION. TENANT SHALL EMPLOY CONTRACTOR DESIGNATED BY LANDLORD TO COMPLETE ALL CONNECTIONS TO SWITCHGEAR AND FOR FUSE INSTALLATION (COORDINATED W /LANE LORD'S CONTRACTOR) EP 24 HR. 7 -DAY 3 POLE SINGLE THROW TIME CLOCK TEL TEL CONNECTION J-BOX SPACE AT FOOD COURT 75 KVA, 480V- 120/208V LOCATED ELECTRICAL ROOM MAIN Sw_ EXIST TELEPHONE TERMINAL BOARD \---- " C.D. W /PULL WIRE BY LANDLORD TENANTS CONTRACTOR TO PULL -IN TELEPHONE CABUNG PROP OWNER EXIST ELEC. ROOM VERIFY LOCATION RISER DIAGRAM SCALE N.T.S. EXIST SWITCHBOARD VERIFY SIZE AND TYPE SEPARATE PERMIT REQUIRED FOR: p Mechanical ❑ Electrical Plumbing LGas Piping City of Tukwila BUILDING DIVISION THOMAS LI AND JOHN BLACKLAW 1602212TH AVE. SW. BURiEN WA. 98166 TEL 206228.8030 Ik7EEO TOE CODE COMPLIANCE E NFPA MAR 1 0 2888 City Of Tukwila BUILDING QJ 1 ION ELECTRICAL SYMBOLS [ !VISIONS No changes shall be made to the scope of work wilt out prior approval of Tukwila 3uilding Division. NOTE and � require � new plan submittal may plan review fees. EP ELECTRICAL PANEL, 200A, 3PHASE 120/208V.4W. 42CKTS ORECEPTACLE 208V. 1PHASE, 2 POLE (TIP SWITCH (D- DIMMER) DUPLEX RECEPTACLE, 120 -VOLT, 1 PHASE DI MOTOR STARTOR SIZE -0(KEF /MAU) (LOCATED BY INSTALLER) 0 11 JUNCTION BOX AS REVD DENOTES 2 #12- 3 /4"C(ONE NEUTRAL) (THHN,CU) CjkFAN MOTOR W/A 30A DISCONNECT FUSE 3P- WP -30AF KEF > E- 22,24,26 /4-#12-3/4"C 3P- WP -30AF MAU ON ROOF (FIELD VERIFIED) >E-28,30,32 4- #12 -3/4 "C NOTES: 1. JUNCTION BOX SHALL BE INCLUDED WHEREVER NEEDED. ALL WIRE SHALL BE #12 OTHERWISE NOTED & SHALL BE MET CODES REQUIPMENT (THHN,CU) 2. PROVIDE INSULATION GROUND WIRE FOR ALL EQUIPMENTS PER NEC - 250 -95. 3. INTERLOCKING SYSTEM SHALL BE PROVIDE FOR CUT OFF GAS VALVE, MAKE -UP AIR FAN & LEAVE EXHAUST FAN ON. 4. ALL LIGHTING SYSTEM SHALL BE MET LOCAL CODES AND STATE CODES. 5. CONTRACTOR SHALL FINISH WIRED FOR ALL EQUIPMENT INCLUDING EXH, SYSTEM RECEPTACLES, & LITS INSIDE THE HOOD. 6. DISCONNECT SWITCH SHALL BE PROVIDE FOR EXHAUST FAN SYSTEMAND MAKE -UP AIR FAN SYSTEM. 7. CONTRACTOR TO VERIFY THE ACTUAL LOADING OF EQUIPMENT AND SIZE BEFORE INSTALLATION. 8. WIRE COLORS- PHASE A- BLACK, PHASE B -RED PHASE C- BLUE, NEUTRAL - WHITE ELO5zzo PROJECT TITLE: AND WESTFIELD MALLCWILA, WA) SHAT TITLE: ELETRICAL SYSTEM REVISIONS INTERIOR DESIGN: CATCH DESIGN STUDIO DRAWN THOMAS Ll CHECKED DATE: 02 /27/08 SCALE- AS NOTED FILE SI-EET# ,CE,I -- E MAR 0 5 2000 PEWIT GEN t.- .