Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL08-0566 - WESTFIELD SOUTHCENTER MALL - SOLSTICE
SOLSTICE 201 SOUTHCENTER MALL ELO8-566 Cityif Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2623049023 Address: 201 SOUTHCENTER MALL TUKW Suite No: ELECTRICAL PERMIT Permit Number: EL08 -566 Issue Date: 09/18/2008 Permit Expires On: 03/17/2009 Tenant: Name: SOLSTICE Address: 201 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: MARCIA PEDDICORD Phone: 206 -802 -6071 Address: 633 SOUTHCENTER MALL TRAILER #3 , TUKWILA WA Contractor: Name: HAGGARD ELECTRICAL CONTRACTORS LLC Phone: 425- 949 -4004 Address: 16702 65 AV SE , SNOHOMISH WA Contractor License No: HAGGAEC960DA Expiration Date: 03/01/2010 DESCRIPTION OF WORK: PROVIDE AND INSTALL NEW CONDUITS, CONDUCTOR AND ELECTRICAL EQUIPMENT Value of Electrical: $15,000.00 Fees Collected: $410.00 Type of Fire Protection: SPRINKLERS /AFA National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: - Date: 9 Q � ate: 1 1 Zi I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of t does not pres constructio • r the perfo ance of work. Signature: ve authority to violate or cancel the provisions of any other state or local laws regulating thorized to sign and obtain this electrical permit. Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Date: 9 [ 18 l a� doc: EL -4/07 EL08 -566 Printed: 09-18 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2623049023 Address: 201 SOUTHCENTER MALL TUKW Suite No: Tenant: SOLSTICE PERMIT CONDITIONS Permit Number: EL08 -566 Status: ISSUED Applied Date: 05/13/2008 Issue Date: 09/18/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the perfo - •f work. Signature: Print Name: Date: 9 as /oZ doc: Cond -Elec EL08 -566 Printed: 09 -18 -2008 CITY OF TUKWIL1) Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www. ci. tkwila. wa. us Electrical Permit No. E L..0 L - sto RA' I Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 2.62.304_ 9032. Site Address: 2.01 SOUTHGEKTIER t4A L1L TUKW ILA, Suite Number: Tenant Name: WA 98 t88 SOLST ICS Property Owners Name: WEST FIELD Slot +ICE t 4T <r Q Mailing Address: 633 SOUTticFNTER ?AR}($AV, ii)KWILA ANNA City New Tenant: Floor: ❑ Yes ID ..No 8188- 2.8$8- State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: M A RCA A `PG DPI CORD Day Telephone: c200802.- 601- Mailing Address: 633 SOOT K C Ia t T ER, PARKWAY/ E -Mail Address: ry, FeacErGor 1i$. vijestcreLl .C.C)ax Number: 2O 24 4 — 4044 ELECTRICAL CONTRACTOR INFORMATION 7 VKKILLA , WA 9S LS r -2R* * City State Zip Company Name: TO $E, pETERMImE Mailing Address: City State Zip Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: Valuation of Project (contractor's bid price): $ 15, 000 Scope of Work (please provide detailed information): TENANT W 1 LL. CO N I.l EGT TO LA NP LoRIA I= xISTIKG SI4tTCKBoARD. T MAT SHALL PRDYIDE Alsip INSTAL1. ALL NEW CONDUITS, CONUvc1TbR At•1p ELECrRIGAt_ tauirtvia -i- Will service be altered? ❑ Yes 42/No Adding more than 50 amps? .Yes ❑ No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel N2reTenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: .Puget Sound Energy ❑ Seattle City Light H:\Apphcauons \Forms- Apphcaunns On Line\4 -2007 - Electncnl Permit Applicauon.doe hh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ca ❑ Meter /mast repair $65.00 ❑ Low voltage systems 555.00 (alarni, furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fec schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW TIIE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR TIIIS PERMIT. BUILDING OWNER OR ELECTRICAL CONT : CTOR: Signature: Print Name: A2414iC i #) PS:t00/c o �� Mailing Address: X33 e. k- 71'4 ley 4f....3 Day Telephone: tfre Date: S //3 708' City .Dv8'- X62- 607/ 9( State Zip IDate Application Accepted: E t 3 _ 0 8 Date Application Expires: I( 13. Q Staff Initials: H:WpplicaI onsTorms- Applications On Lm64-2007 - Electrical Permit Application.doc bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049023 Permit Number: EL08 -566 Address: 201 SOUTHCENTER MALL TUICW Status: APPROVED Suite No: Applied Date: 05/13/2008 Applicant: SOLSTICE Issue Date: Receipt No.: R08 -03288 Payment Amount: $328.00 Initials: WER Payment Date: 09/18/2008 11:44 AM User ID: 1655 Balance: $0.00 Payee: HAGGARD ELECTRICAL TRANSACTION LIST: Type Method Descriptio Amount Payment Check 14760 328.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 328.00 Total: $328.00 rinr.• Rarnint -OR Printari• f14- 1R -7nnR 3 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit a05g- S(h PERMIT NO. (206)431 -3670 Project: sole ! T1 Ct Type of Inspection: 2/00 Address: Zo, Date Called: --. Special Instructions: Date Wanted: it 01 4:n. Requester: t Phone No: Approved per applicable codes. D Corrections required prior to approval. COMMENTS: OK. ,- ru\lirt Inspector: 1Date: R1/o1 r0\8 El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 1Date: 2 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 'tom 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: 4 ..)61.5rlt� Type of Inspection: 7003 Address: Zo ‘ til Date Called: Special Instructions: Date Wanted: /O /l 4 �a - Requester: Phone No: 'Approved per applicable codes. El Corrections required prior to approval. COMMENTS: -K. , 9to spuzictepAir 1 (14-14.. T 64-1 Inspector: j r 6 (`�, Date: /aro4J ni 'paid REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: t.�...� ,e+e1+.1.204. .is r• • •• • a •rtiw INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: �L DTI Type of Inspection: loot 7 po) Address: } 1.4) �M B 'sVv Date Called: Special Instructions: Date Wanted: 7 /3o cai.t... 'Requester: Phone No: IDApproved per applicable codes. ElCorrections required prior to approval. 7 COMMENTS: r tyctPr STO RF�°'M El$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 2006 Washington State Nonresidential Energy Code Compliance Form t, Project Summary PRJ -SUM 2008 Washington state Nonreadentier Energy Code Compliance Forms Revised July 2009 Project Info Project Address . 201 South Center mail Date 5/8/2008 Tukwila, WA 89188. For Building Department Use Applicant Name: Kelly Hyde Applicant Address: 7330 U. 16th St. suite A110 Phoenix, A2 85020 Applicant Phone: 602- 336 -5231 FILE COPY Permit iiloa pnreval i; subject e err!! am omssien3. fiOL't'.°rpfl$; not authorial 1 11,nf.-'s-% I BCODE COMPLIAN FOR NFPA 70_NEC E MAY 1 b ?008 City Of Tukwi la REVIEWED NG DI RECEIVED ;;TTY OF TUKWILA my 113 2008 'ERNiIT CENTEF GlAB ado 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary LTG ;INT 2006 Washington State Nonresidential Energy Code Compliance Fors Revised July 2007 Project Info Project Address 201 south center Mall Date 5/8/2008 Tukwila, WA ems For Building Departrnent Use Sales Applicant Name: Kelly Hyde AppliCantAddress: 7330 N. 16th St. Suite A110 Phoenix, A2 85020 Applicant Phone: 602- 336 -5231 Project Description ❑ Plans Included requirements.. al New Building ❑ Addition ❑ Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option 0 Prescriptive ® Ughting Power Allowance (See Qualification Checklist (over). Indicate Prescriptive & LPA 0 Systems Analysis • spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) 50.0 al No changes are being made to the lighting ❑ Less than 60% of the fixtures new. installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2 " Area in ft2 Allowed x Area Sales Retail 3.00 595.0 1785.0 Stockroom Retail storage 1.50 136.0 204.0 Raatroom Common area (Restrooa) 0.80 50.0 40.0 rom Table 15-1 (over) - document all exceptions on form LTG -LPA Proposed Lighting Wattage Total Allowed Watts 2029.01 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Sales Type C 20W Metal Halide R4.5 Downlight 18 23.0 414.0 Type G 70W Metal Halide, Par30 Flood Adjustable Downli5 .16 79.0 1264 .0 Type H 50W Halogen Accent Light 2 50.0 100.0 Stockroom Type F2 4' 75 28W Strip Fluorescent 3 68.0 204.0 Restroom Existing Fluorescent Strip 1 31.0 31 .0 otal Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 2013.0 Notes: 1. For proposed Fixture Description, indicate fodure type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if Included). For track lighting, list the length of the track (in.feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplled by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary (back) 2006 Washington State Nonresidential Energy Code Compliance Fame LTG -INT Revised .dy 2007 Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers *Other Qualification Checklist Note: tf occupancy type is other and ri.,ie answer is checked, the number of fi tures in the space Is not limited by Code. Clearly indicate these spaces on plans. If not qualified. do LPA Calculations. Lighting Fixtures: (Section 1521) 0.9 .1 Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non- lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T -1, T-2, T-4, T -5, T-8 lamps, and d) hard -wired elect tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. -1 Unit Lighting Power Allowance (LPA Use' LPA` (W /sf) Use' LPA` (W /sf) Automotive facility • - 0.9 Office buildings, officeladministrative areas in facilities of other use types (including but not limited to schools,, hospitals, institutions, museums, banks, churches) 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire station? 1.0 Cafeterias, fast food establishment?, restaurants/bars5 1.3 Post office 1.1 Dormitory 1.0 Retail's, retail banking, mall.concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia ", assembly space? 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel/motel 1.0 Warehouses ", storage areas 0.5 . Hotel banquet/conference/exhibition halls•' 2.0 .Workshops 1.4 Laboratory spaces (all spaces not classified laboratory' shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 • Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Footnotes for Table 15-1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use Is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceding height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 15062 with full height partitions, a Unit Lighting Power Allowance of 1.10 w/ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W/ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three-quarter- height partitions (transparent or opaque). and lighting for free- standing display where the lighting moves with the display are exempt. An additional 1.5 w/ft' of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -566 DATE: 5 -13 -08 PROJECT NAME: SOLSTICE SITE ADDRESS: 201 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS:6. B g sibn Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete ri DUE DATE: 5-15 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURSR9UTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 6-12-08 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip doc 2 -28 -02 Untitled Page • • Page 1 of 2 Electrical Contractor A business licensed by Lai to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company HAGGARD ELECTRICAL CONTRS LLC 4259494004 16702 65TH AVE SE SNOHOMISH WA 98296 SNOHOMISH LIMITED LIABILITY COMPANY UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 602357747 ACTIVE HAGGAEC960DA ELECTRICAL CONTRACTOR 3/1/2004 3/1/2010 HAGGAR*964CL GENERAL UNUSED ADMINISTRATOR INFORMATION License HAGGAR*964CL Name HAGGARD, RYAN Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date HAGGARD, RYAN L PARTNER /MEMBER 03/01/2004 Bond HAGGARD, ELIZABETH A PARTNER /MEMBER 03/01/2004 Account Bond Information Bond Bond Bond Effective Expiration Cancel Impaired Bond Received Company Account Date Date Date Date Amount Date https: / /fortress.wa. gov /lni/bbip/Detail. aspx ?License= HAGGAEC960DA 09/18/2008 SEPARATE PERMIT REQUIRED FOR: (Mechanical ❑ Electrical Plumbing NI Gas Piping City of Tukwila BUILDING DIVISION ELECTRICAL POWER PLAN 1/4"=1'-0" EXISTING PNLBD —LA REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. GENERAL NOTES: 1. PROVIDE ANY FIRE ALARM INITIATION DEVICES AND /OR NOTIFICATION DEVICES ARE REQUIRED TO MEET LOCAL CODE, CONTRACT AND THE AHJ REQUIREMENTS. POWER PLAN KEYNOTES: DEDICATED ISOLATED GROUND RECEPTACLE AND CIRCUIT FOR POINT OF SALE REGISTER. REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING DETAIL. COMBINATION DATA /TELEPHONE OUTLET. PROVIDE 1" EMPTY CONDUIT WITH PULLSTRING FROM OUTLET TO TELEPHONE BACKBOARD. COORDINATE REQUIREMENTS WITH OWNER AND ARCHITECT PRIOR TO ROUGH —IN. PROVIDE (4) 1 " CONDUIT RUNS IN FLOOR FOR POWER, DATA, AND SECURITY CIRCUITS. SAWCUT AND PATCH SLAB. COORDINATE FLOOR CUTTING WITH LANDLORD PRIOR TO STARTING WORK. 1 2 3 4 PROVIDE 1" CONDUIT WITH PULLSTRING BACK TO TELEPHONE BOARD. 5 1 PROVIDE 1 " CONDUIT WITH PULLSTRING BACK TO SECURITY PANEL. 6 7 8 9 10 11 12 13 14 L5J 16 17 18 19 STUB CONDUIT UP TO JUNCTION BOXES IN WALL ABOVE ACCESSIBLE CEILING. EXISTING J —BOX AND 120V, 10 CIRCUIT FOR STOREFRONT SIGN TO REMAIN. ROUTE CIRCUIT THROUGH TIME SWITCH. COORDINATE EXACT LOCATION WITH ARCHITECT PRIOR TO ROUGH —IN. ELECTRICAL CONTRACTOR SHALL PROVIDE PERMANENT YELLOW TAPE ON FLOOR TO IDENTIFY A WORKING CLEARANCE 3' -0" BY 30" WIDE MINIMUM SPACE PER PANEL. THIS SPACE SHALL BE MARKED "NO STORAGE ". PROVIDE 30A /3P FUSIBLE DISCONNECT SWITCH WITH 20A LPN —RK5 FUSES FOR MECHANICAL UNIT (OU -1). REFER TO MECHANICAL SHEETS FOR ADDITIONAL INFORMATION. PROVIDE TELEPHONE BACKBOARD, 2'X2' WITH THE BOTTOM MOUNTED 48" AFF WITH #4 COPPER GROUND TO EXISTING TTB. DEDICATED RECEPTACLE AND CIRCUIT FOR SECURITY PANEL. SECURITY MASTER PANEL PROVIDED BY OTHERS. FOR EACH SECURITY DEVICE, PROVIDE DEVICE BACKBOXES AND 1 " CONDUIT WITH PULLSTRING BACK TO SECURITY PANEL. REFER TO SECURITY SHOP DRAWINGS FOR ADDITIONAL INFORMATION. REFER TO ARCHITECTURAL SHEETS FOR EXACT MOUNTING HEIGHTS FOR WORKSTATION DEVICES. PROVIDE TIME SWITCH IN NEMA 1 ENCLOSURE. TIME SWITCH SHALL BE A PROGRAMMABLE 8 —POLE, 24 —HOUR, 7 —DAY. PROVIDE 60A /2P FUSIBLE DISCONNECT SWITCH WITH 40A LPN —RK5 FUSES FOR MECHANICAL UNIT (IU -1). REFER TO MECHANICAL SHEETS FOR ADDITIONAL INFORMATION. LOCATION OF SECURITY KEY PAD AND ALARM PUSHBUTTON. SECURITY DEVICES PROVIDED BY OTHERS. COORDINATE WITH ARCHITECT PRIOR TO ROUGH —IN. PROVIDE JUNCTION BOX FOR FUTURE SENSORMATIC EQUIPMENT. COORDINATE EXACT LOCATION WITH ARCHITECT PRIOR TO ROUGH —IN. EXISTING SHOW WINDOW RECEPTACLES MOUNTED FLUSH IN CEILING. COORDINATE FINISH WITH ARCHITECT AND REPLACE AS NECESSARY. ROUTE CIRCUIT THROUGH TIME SWITCH. REFER TO NOTE 13 FOR ADDITIONAL INFORMATION. EXISTING WATER HEATER AND CIRCUIT TO REMAIN. PROVIDE 20A/1P MOTOR RATED TOGGLE SWITCH FOR MOTORIZED DAMPER. CONTROLS PER DIVISION 15. REFER TO MECHANICAL SHEETS FOR ADDITIONAL INFORMATION. FILE C• PY Permit No. Piar review approval is subject to errors and omissions. Approval of construction documents does authorize the violation of any adopted code or �' Hera ,:. Receipt o! epprowr field Copy J $ �.. _ edged: City of Tukwila BUILD1NC DIVISION RECEIVED crri OF TUKWII_.,= MAI 1/213 NOB VCRMrrCENfI~ 1 NOTE: EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS & SITE VISITS AND MAY NOT REFLECT EXACT "AS— BUILT" CONDITIONS. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. FLHENDERSON ENGINEERS= 8325 LENEXA DRIVE LENEXA, KS 66214 TEL 913 742 5000 FAX 913 742 5001 www.hei- eng.com 0750002188 RSP Architects 502 S. College Avenue Suite 203 Tempe, AZ 85281 Certification 480.889.2000 480.889.2099 fax www.rsparch.com RSP Architects, Ltd. with Terry Wobken Washington No. 6634 Location Westfield Southcenter 201 Southcenter Mall Tukwila, WA 98188 Project For Project No. Drawn By 1688.005.02 KH Checked By CL Date 05.06.08 NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of ASP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright ASP Architects 2003. All rights reserved. ELECTRICAL POWER PLAN E101 C: \Solstice \0750002188 Solstice - South Center - Tukwila - WA\000 \Elec \0750002188E102.dwg, Plot, 5/8/2008 12:19:05 PM, kellyhyde, 1:1.00251 0 r LA -22 L LA -24 A -10 SW —'c' G G LA— 6 SW—'b' __________ rj C ELECTRICAL LIGHTING PLAN 1/4 " =1' -0" 2 EXISTING PNLBD —LA GENERAL NOTES: 1. PRIOR TO ROUGH —IN, REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF LIGHT FIXTURES. LIGHTING PLAN NOTES: 2 3 4 5 6 7 8 9 10 11 CIRCUIT SHALL BE CONTROLLED BY TIME SWITCH. REFER TO SHEET E101 FOR ADDITIONAL INFORMATION. NORMAL POWERED AND EMERGENCY DISCHARGE LIGHTING IN THIS AREA IS PROVIDED BY LANDLORD. FIXTURE SHALL ALWAYS BE ON AS NIGHT LIGHTS. PROVIDE OUTLET BOX FOR CONNECTION TO FEATURE CABINET. VERIFY REQUIREMENTS AND MOUNTING HEIGHTS WITH ARCHITECT. HOME RUN CIRCUIT THROUGH SWITCH 'f'. MASTER LIGHTING SWITCHBANK. REFER TO DETAIL 2, THIS SHEET, FOR ADDITIONAL INFORMATION. PROVIDE OUTLET BOX FOR CONNECTION TO FEATURE CABINET. VERIFY REQUIREMENTS AND MOUNTING HEIGHTS WITH ARCHITECT. HOME RUN CIRCUIT THROUGH SWITCH 'g'. PROVIDE UN— SWITCHED HOT FOR EMERGENCY LIGHTING. PROVIDE UNSWITCHED HOT LEG FOR EMERGENCY LIGHTING. LIGHTS SHALL ALWAYS BE ON AS NIGHT LIGHTS. PROVIDE OUTLET BOX FOR CONNECTION TO FEATURE WALL. VERIFY REQUIREMENTS AND MOUNTING HEIGHTS WITH ARCHITECT. HOME RUN CIRCUIT THROUGH SWITCH 'h'. CONTINUATION TO EXISTING RESTROOM LIGHTING CIRCUIT. CONTRACTOR SHALL TIE EXISTING FIXTURES INTO NEW CIRCUIT. COORDINATE EXACT REQUIREMENTS IN FIELD PRIOR TO ROUGH —IN. PROVIDE 20A /1P MOTOR RATED TOGGLE SWITCH FOR NEW RESTROOM EXHAUST FAN. RESTROOM EXHAUST FAN SHALL BE CONTROLLED VIA EXISTING RESTROOM LIGHT SWITCH. REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION. SALES a SALES DISPLAY SALES SALES DISPLAY STOCK SALES 'e' 'f' STOCKROOM FEATURE LIGHTING CASE SALES c SALES GENERAL SALES I1'g, FEATURE CASE SALES � 'd' SALES GENERAL SPARE 'h' FEATURE WALL NOTE: ALL SWITCHES SHALL BE MOUNTED NO HIGHER THAN +43" CENTERLINE AFF. 2 SWITCH NO SCALE BANK DETAIL ELD8 5b0 LIGHT FIXTURE SCHEDULE TYPE MANUFACTURER /MODEL # LAMPS INPUT INPUT DESCRIPTION NO. TYPE VOLT WATTS VA C LIGHTOLIER — CALCULITE 1 20W T4.5 120 23 26 4 -1/2" METAL HALIDE RECESSED WIDE BEAM DOWNLIGHT. HIGH EFFICIENCY ELECTRONIC C4T4VW C420T4E1 CERAMIC METAL BALLAST. UL LISTED. VERIFY FINISH AND REFLECTOR OPTIONS WITH ARCHITECT. HALIDE, 3000K G PATHWAY — COVENTRY SERIES 1 70W MHPAR 30 120 79 84 6" RECESSED DOWN LIGHT WITH PAR 30 LAMP, INTEGRAL BALLAST, CRYSTAL CLEAR 6AMP3070E4 MASTER COLOR PRISMATIC SPREAD LENS, SPECTACULAR ALZAK CLEARER CONE AND WHITE TRIM FINISH. FLOOD 30' CMD35/ PAR30 /FL /3000K H LYTECASTER 1 50W MR16 120 50 50 4" RECESSED ADJUSTABLE DOWNLIGHT. ADJUSTABLE LAMP ASSEMBLY CAPABLE 300MRX WITH 308ALX INCANDESCENT OF 358 DEGREES OF ROTATION AND 30 DEGREES OF TILTING. UL LISTED FOR MAXIMUM WATTAGE OF 50W. SEE NOTE 7. F2 MERCURY LIGHTING 2 28W T5 LINEAR 120 68 70 4' LINEAR FLUORESCENT STRIP LIGHT FIXTURE WITH DIE FORMED HEAVY GAUGE MB- 2- 28— T5— ELB —UNV FLUORESCENT COLD ROLLED STEEL HOUSING AND END PLATE. HIGH EFFICIENCY ELECTRONIC WG— MM -2 -32 BALLAST. UL LISTED. LAMP WATTAGE MUST NOT EXCEED 28W. F2 /EM MERCURY LIGHTING 2 28W T5 LINEAR 120 68 70 4' LINEAR FLUORESCENT STRIP LIGHT FIXTURE WITH DIE FORMED HEAVY GAUGE MB- 2- 28 —T5— ELB — UNV — EMPK /ISL540 FLUORESCENT COLD ROLLED STEEL HOUSING AND END PLATE. HIGH EFFICIENCY ELECTRONIC WG— MM -2 -32 BALLAST. UL LISTED. LAMP WATTAGE MUST NOT EXCEED 28W. PROVIDE WITH 2 —LAMP EMERGENCY BALLAST WITH 90 MINUTE BATTERY BACK —UP AT 1300 LUMENS. EM COOPER SURE —LITES 1 25W INCANDESCENT 120 25 25 8" RECESSED GIMBAL EMERGENCY LIGHT FIXTURE WITH 20 GAUGE DIE — STAMPED RG2 —WH STEEL HOUSING AND POLYCARBONATE LENS. SEALED LEAD CALCIUM BATTERY. UL LISTED. FIXTURE SHALL PROVIDE 318 INITIAL LUMENS OUTPUT. EM2 CONCEALITE 2 35W MR16 LAMPS 120 35 23 RECESSED FLUSH MOUNTED EMERGENCY FIXTURE WITH INTEGRAL 90 MINUTE F5 -35 -90 INCLUDED _ BATTERY PACK. XC CON TECH LED (INCLUDED) 120 5 5 EDGE —LIT CEILING MOUNTED EXIT SIGN WITH INTEGRAL 90 MINUTE BATTERY EXELSFRLEDEM —P BACK —UP. UL LISTED. XW COOPER LED (INCLUDED) 120 5 5 WALL MOUNTED EMERGENCY EXIT SIGN WITH 90 MINUTE BATTERY BACK —UP. AP70R WH NOTES: TYPICAL FOR ALL 1. PROVIDE UNIT — PRICING ALONG WITH MANUFACTURER AND MODEL NUMBER FOR ALL LIGHT FIXTURES. NO PACKAGING OR LUMP SUM PRICING OF LIGHT FIXTURES SHALL BE ALLOWED. AT CONTRACTOR'S OPTION, ALTERNATE LIGHT FIXTURES MAY BE SUBMITTED. HOWEVER, ALTERNATE FIXTURES MUST BE SUBMITTED FOR REVIEW AT BID OPENING, MUST INCLUDE UNIT — PRICING AND INCLUDE ALL APPLICABLE INFORMATION NECESSARY FOR REVIEW AND EVALUATION; REFER TO SPECIFICATION 16500. 2. VERIFY CEILING CONDITIONS AND COORDINATE LIGHT FIXTURE MOUNTING HARDWARE NEEDED TO SUIT CEILING CONDITIONS PRIOR TO ORDERING. 3. VERIFY MODEL NUMBERS AND DESCRIPTIONS WITH MANUFACTURER PRIOR TO PLACING ORDER. 4. VERIFY FINISH AND COLOR WITH ARCHITECT PRIOR TO PLACING ORDER. 5. REFER TO ARCHITECTURAL DRAWINGS AND DETAILS FOR EXACT LOCATIONS, MOUNTING HEIGHTS AND ADDITIONAL MOUNTING INFORMATION. 6. CATALOG NUMBER REPRESENTS MANUFACTURER LISTED FIRST. OTHER MANUFACTURERS LISTED ARE CONSIDERED EQUIVALENT FOR SUBSTITUTION. 7. PROVIDE MAXIMUM WATTAGE LABEL ON INCANDESCENT AND HALOGEN LIGHT FIXTURES THAT CORRESPOND TO THE MAXIMUM WATTAGE INDICATED IN THIS LIGHT FIXTURE SCHEDULE. 8. CONTRACTOR SHALL SUPPLY A COMPLETE AND OPERATIONAL SYSTEM TO COMPLY WITH DESIGN INTENT. 9. DUE TO AESTHETIC OR PERFORMANCE CRITERIA, SPECIFIED MANUFACTURER SHALL BE THE ONLY MANUFACTURER ALLOWED TO BID UNLESS OTHERWISE APPROVED BY ARCHITECT. 10. BURN IN CERAMIC METAL HALIDE LAMPS FDR 100 HOURS PRIOR TO TURNOVER OF PROJECT TO OWNER. 11. REFER TO DIVISION 16 SPECIFICATIONS FOR ACCEPTABLE FLUORESCENT AND HID BALLAST MANUFACTURERS. REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC MAY 1 6 2008 City Of Tukwila B ILDING DIVI I I N Crry OF TUKWIIA MAY X13 BOB pERM1- Gaffey; i 1HENDERSON ENGINEERS 8325 LENEXA DRIVE LENEXA, KS 66214 TEL 913 742 5000 FAX 913 742 5001 www.hei- eng.com 0750002188 RSP Architects 502 S. College Avenue Suite 203 Tempe, AZ 85281 Certification 480.889.2000 480.889.2099 fax www.rsparch.com RSP Architects, Ltd. with Terry Wobken Washington No. 6634 Location Westfield Southcenter 201 Southcenter Mall Tukwila, WA 98188 Project For Project No. Drawn By 1688.005.02 KH Checked By CI_ D ate 05.06.08 NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of ASP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright ASP Architects 2003. All rights reserved. ELECTRICAL LIGHTING PLAN E102 O: \Solstice \0750002188 Solstice - South Center - Tukwila - WA \000 \EIec10750002188E201.dwg, Plot, 5/8/2008 12:18:29 PM, kellyhyde, 1:1.00251 ELECTRICAL SYMBOLS I NOTE' THIS IS A MASTER LEGEND AND NOT ALL SYMBOLS, ABBREVIATIONS, ETC. ARE NECESSARILY USED ON THE DRAWINGS. ELECTRICAL ONE -LINE & RISER 1 800A 3P 1200AS 3P 200AF FRS GFR BS UTILITY METER ©, TVSS ## PAN ELBOARD (SEE SCHEDULES) TRANSFORMER TYPE AND RATINGS AS SHOWN SWITCH RATING AS SHOWN CIRCUITING & WIRING WIRING DEVICES & OUTLETS FUSED SWITCH RATING,POLES AND FUSE TYPE AS SHOWN ; TX# II 1 225A ( 3P MULTI - SECTION PAN ELBOARD (SEE SCHEDULES) SHIELDED TRANSFORMER TYPE AND RATINGS AS SHOWN CIRCUIT BREAKER RATINGS AS SHOWN CIRCUIT IDENTIFICATION - SEE CIRCUIT SCHEDULE GROUND FAULT RELAY SHUNT TRIP UTILITY METER (AS REQUIRED BY UTILITY) CURRENT TRANSFORMER RATING AS SPECIFIED OR REQUIRED TRANSIENT VOLTAGE SURGE SUPPRESSOR GROUND CONNECTION GROUND ROD CONTACT (OPEN OR CLOSED) HEATER MOTOR BLOCK LOAD KW OR KVA 53 P1 OR P1 -3,5,7 SWITCHED HOT CONDUCTORS (SHOWN TRAILING NEUTRAL) NEUTRAL CONDUCTOR UNSWITCHED HOT CONDUCTORS (SHOWN LEADING NEUTRAL) HOMERUN TO PANELBOARD, ARROWS INDICATE NUMBER OF CIRCUITS, HASH MARKS INDICATE NUMBER OF CONDUCTORS. INFORMATION AT ARROWS ARE CIRCUIT NUMBERS AND PANELBOARD. EQUIPMENT GROUNDING CONDUCTOR IN CONDUIT (GREEN INSULATION OR BARE) ISOLATED GROUNDING CONDUCTOR IN CONDUIT (GREEN INSULATION WITH YELLOW TRACER) CONDUIT CONCEALED CONDUIT IN /UNDER FLOOR /GROUND CONSTRUCTION EXPOSED CONDUIT FLEXIBLE CONDUIT LOW VOLTAGE CABLE (NOT ROUTED IN CONDUIT) D CONDUIT TURNING DOWN 0 CONDUIT TURNING UP CONNECTION POINT OR EQUIPMENT TERMINATION : EQUIPMENT TERMINATION LIGHTING SIGNALING SIGNALING BELL SIGNALING BUZZER LV TRANSFORMER ABBREVIATIONS A AMPERES, AIR (COMPRESSED) A/C AIR CONDITIONING AF AMPERE FUSE AFC ABOVE FINISHED CEILING AFC! ARC FAULT CIRCUIT INTERRUPTER AFEA AREA FOR EVACUATION ASSISTANCE AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE Al ANALOG INPUT AIC AMPERE INTERRUPTING CURRENT AL ALUMINUM AO ANALOG OUTPUT AP ACCESS PANEL ATS AUTOMATIC TRANSFER SWITCH AWG AMERICAN WIRE GAUGE BAS BUILDING AUTOMATION SYSTEM BFF BELOW FINISHED FLOOR BFG BELOW FINISHED GRADE BI BINARY INPUT BKR BREAKER BO BINARY OUTPUT C CONDUIT CD CANDELA CT CURRENT TRANSFORMER CAN CABLE TELEVISION SYSTEM CCTV CLOSED CIRCUIT TELEVISION CKT CIRCUIT CPT CONTROL POWER TRANSFORMER CU COPPER, CONDENSING UNIT CVD CUMULATIVE VOLTAGE DROP DDC DIRECT DIGITAL CONTROL DI DIGITAL INPUT, DUCTILE IRON DN DOWN DPDT DOUBLE -POLE, DOUBLE -THROW DPST DOUBLE -POLE, SINGLE -THROW EM EMERGENCY EPO EMERGENCY POWER OFF ETR EXISTING TO REMAIN FACP FIRE ALARM CONTROL PANEL FBO FURNISHED BY OTHERS /OWNER FCA FAULT CURRENT AMPS FF FINISHED FLOOR FLA FULL LOAD AMPS FLR FLOOR FVNR FULL - VOLTAGE, NON- REVERSING GC GENERAL CONTRACTOR GFCI GROUND FAULT CIRCUIT INTERRUPTER GFR GROUND FAULT RELAY G GROUND GND GROUND GRS GALVANIZED RIGID STEEL HOA HAND -OFF- AUTOMATIC IG ISOLATED GROUND ISC SHORT CIRCUIT CURRENT JB JUNCTION BOX J -BOX JUNCTION BOX kcmil 1000 CIRCULAR MILS KK KIRK KEY kV KILOVOLT kVA KILOVOLT -AMPS kVAR KILOVOLT -AMPS REACTIVE kW KILOWATT kWH KILOWATT -HOUR LF LINEAR FEET MAN MASTER ANTENNA TELEVISION SYSTEM MAX MCA MCB MCC MD MDP MFR MG MH MIN MLO MOCP MSB MSWB MS /TP MTD N/A N/C NIC NL N/O OC OS PDU PH, 0 PIV PNL PNLBD MAXIMUM MINIMUM CIRCUIT AMPACITY MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MOTORIZED DAMPER MAIN DISTRIBUTION PANEL MANUFACTURER MOTOR GENERATOR MANHOLE MINIMUM MAIN LUGS ONLY MAXIMUM OVERCURRENT PROTECTION MAIN SWITCHBOARD MAIN SWITCHBOARD MASTER SLAVE /TOKEN PASSING COMMUNICATION TRUNK MOUNTED NOT APPLICABLE NORMALLY CLOSED NOT IN CONTRACT NIGHT LIGHT NORMALLY OPEN ON CENTER OCCUPANCY SENSOR POWER DISTRIBUTION UNIT PHASE POST INDICATOR VALVE PANEL PANELBOARD PROVIDE FURNISH AND INSTALL PT POTENTIAL TRANSFORMER PTZ PAN, TILT, ZOOM QUANTITY RECEPTACLE RUNNING LOAD AMPS ROOFTOP UNIT SMOKE DETECTOR, SUPPLY DUCT SQUARE FEET, SUPPLY FAN SINGLE -POLE, DOUBLE -THROW SINGLE -POLE, SINGLE -THROW STAINLESS STEEL, SANITARY SEWER, SOIL STACK ST SHUNT TRIP, STEAM TRAP SWBD SWITCHBOARD TL TWISTLOCK TR TAMPER RESISTANT TX TRANSFORMER TYP TYPICAL U/F UNDERFLOOR U/C UNDERGROUND UH UNIT HEATER U/S UNDERSLAB UL UNDERWRITERS LABORATORIES, INC. UNLESS NOTED OTHERWISE UNINTERRUPTIBLE POWER SUPPLY VOLT(S) VOLTS ALTERNATING CURRENT VOLTAGE DROP VOLTS DIRECT CURRENT VARIABLE FREQUENCY DRIVE WIRE WEATHERPROOF EXPLOSION -PROOF QTY RCPT RLA RTU SD SF SPDT SPST SS U NO UPS V VAC VD VDC VFD W WP XP A 0 0 a A V FLUORESCENT LIGHT FIXTURE: (SEE LIGHT FIXTURE SCHEDULE) a = SWITCHED BY SWITCH "a" A = LIGHT FIXTURE TYPE "A" FLUORESCENT LIGHT FIXTURE WITH NIGHT LIGHT FLUORESCENT LIGHT FIXTURE WITH EMERGENCY LIGHTING BATTERY PACK FLUORESCENT LIGHT FIXTURE WITH DUAL BALLASTS CIRCUITED SEPARATELY. (SHADING IMPLIES EMERGENCY BALLAST WITH BATTERY PACK) LIGHTING TRACK WITH LIGHT FIXTURE TYPES AS INDICATED 0A LIGHT FIXTURE - CEILING / WALL MOUNTED. y A = LIGHT FIXTURE TYPE "A" O)A WALL WASHER LIGHT FIXTURE - ARROW INDICATES DIRECTION. A = LIGHT FIXTURE TYPE "A" A WALL MOUNTED LIGHT FIXTURE. 8Q A = LIGHT FIXTURE TYPE "A" SITE LIGHTING FIXTURE (SEE LIGHT FIXTURE SCHEDULE) A EXIT SIGN - CEILING / WALL MOUNTED, ARROWS AS INDICATED. (;j A = LIGHT FIXTURE TYPE "A" (SEE LIGHT FIXTURE SCHEDULE) A q=pEMERGENCY BATTERY PACK LIGHT FIXTURE - CEILING /WALL �4 u MOUNTED. (SEE LIGHT FIXTURE SCHEDULE) $2 Oil WP OA m IO ESR SINGLE POLE WALL SWITCH (NO LETTER DESIGNATION) SWITCH LETTER DESIGNATIONS AS FOLLOWS: 2 = TWO POLE WALL SWITCH 3 = THREE -WAY WALL SWITCH 4 = FOUR -WAY WALL SWITCH D = DIMMER TYPE SWITCH OS = OCCUPANCY SENSOR P = SPST PILOT LIGHT SWITCH K = KEYED LIGHT SWITCH M = MOTOR RATED SWITCH WP = WEATHER PROOF CEILING MOUNTED OCCUPANCY SENSOR WITH POWER SUPPLY AND LOAD RELAY AS REQUIRED OR SPECIFIED. SIMPLEX RECEPTACLE - NEMA 5 -20R, UNO DUPLEX RECEPTACLE - NEMA 5 -20R, UNO DOUBLE DUPLEX RECEPTACLE - NEMA 5 -20R, UNO SPECIAL RECEPTACLE - NEMA TYPE AS NOTED TWIST -LOCK TYPE RECEPTACLE GFCI TYPE RECEPTACLE* ISOLATED GROUND TYPE RECEPTACLE* RECEPTACLE INSTALLED RECEPTACLE INSTALLED RECEPTACLE INSTALLED RECEPTACLE INSTALLED 6" ABOVE COUNTER OR BACKSPLASH* IN CEILING* IN FLOOR* VIA DROP CORD* *DUPLEX RECEPTACLE SHOWN, SIMILAR FOR OTHERS RECEPTACLE LETTER DESIGNATIONS AS FOLLOWS: C = CLOCK HANGER TYPE E = EMERGENCY POWER S = SWITCHED IG = ISOLATED GROUND TR = TAMPER RESISTANT WP = WEATHERPROOF MULTI - OUTLET SURFACE RACEWAY WITH NEMA 5 -20R RECEPTACLES 12" ON CENTER, UNO. TELEPHONE OUTLET - FLOOR OR WALL MOUNTED. INSTALL AT SAME ELEVATION AS ADJACENT RECEPTACLE, UNO. DATA OUTLET - FLOOR OR WALL MOUNTED. INSTALL AT SAME ELEVATION AS ADJACENT RECEPTACLE, UNO. MULTI - SERVICE OUTLET - FLOOR OR WALL MOUNTED. INSTALL AT SAME ELEVATION AS ADJACENT RECEPTACLE, UNO. MULTI - SERVICE POWER POLE WITH TELEPHONE, DATA AND POWER OUTLETS A = TYPE, SEE SCHEDULE IN SPECIFICATIONS MULTI - SERVICE FLOOR BOX WITH TELEPHONE, DATA AND POWER OUTLETS A = TYPE, SEE SCHEDULE IN SPECIFICATIONS POKE THROUGH, A = TYPE, SEE SCHEDULE IN SPECIFICATIONS THERMOSTAT JUNCTION BOX /OUTLET BOX JUNCTION BOX /OUTLET BOX BLANK FACE GFCI FEED THROUGH DEVICE EMERGENCY SHUNT RELAY POWER EQUIPMENT & DEVICES STANDARD MOUNTING HEIGHTS (AFF, AFC, UNLESS NOTED OTHERWISE) ELECTRICAL ALARMS ANNUNCIATOR PANELS CLOCK OUTLETS (CENTERLINE) CONTROLS (CENTERLINE) EXIT SIGNS (WALL MOUNTED, BOTTOM) INTERCOM (AFEA ONLY) INTERCOMS PANELS /PANELBOARDS (TOP) PHOTOCELLS RECEPTACLES (CENTERLINE) RECEPTACLES (EXTERIOR) RECEPTACLES (GARAGES) RECEPTACLES IN EQUIPMENT ROOMS REMOTE INDICATING LIGHT (EQUIPMENT ROOMS) REMOTE INDICATING LIGHT (FINISHED AREAS) SAFETY SWITCHES STARTERS SWITCHES (CENTERLINE) TELEPHONES (PUBLIC) TELEPHONE, DATA OUTLETS (CENTERLINE) TELEPHONE TERMINAL BOARD (BOTTOM) TELEVISION OUTLETS 1 © 48 ", 48" 48" 84" 48" 80" 36" 48" 72" 144" 18" 24" 26" 48" 48" CEILING 48" 48" 48" 1 © 36" 18" 6" 18" ANNOTATION 1 ELECTRICAL PLAN NOTE CALLOUT O TECHNOLOGY PLAN CALLOUT 1 EQUIPMENT DESIGNATION (OWNER FURNISHED, CONTRACTOR INSTALLED) CONNECTION POINT OF NEW WORK TO EXISTING DETAIL REFERENCE UPPER NUMBER INDICATES DETAIL NUMBER LOWER NUMBER INDICATES SHEET NUMBER SECTION CUT DESIGNATION e s o » 200/3/150 30/3/15/1 L® ® 2 ll® VFD ELECTRICAL SERVICE PANELBOARD (SURFACE OR FLUSH MOUNT) TERMINAL CABINET (SURFACE OR FLUSH MOUNT), TYPE AS NOTED PLYWOOD TERMINAL BOARD FOR TELEPHONE SYSTEM, UNO. SIZE AS NOTED. ELECTRICAL DISTRIBUTION PANELBOARD SWITCHBOARD OR MOTOR CONTROL CENTER ON HOUSEKEEPING PAD TRANSFORMER MOTOR DISCONNECT SWITCH - "200/3/150" DENOTES AMPERES /POLE /FUSE NF= NON -FUSED CB= CIRCUIT BREAKER (200 /3 /CB) COMBINATION DISCONNECT (SAFETY) SWITCH AND MOTOR STARTER "30/3/15/1" DENOTES AMPERES /POLE /FUSE /NEMA STARTER SIZE NF= NON -FUSED CB= CIRCUIT BREAKER (30/3/CB/1) MAGNETIC MOTOR STARTER, NEMA SIZE AS NOTED. 3 -POLE, UNO. MANUAL STARTER VARIABLE FREQUENCY DRIVE 0 RELAY OR CONTACTOR (IN SCHEMATICS) L PC Fo m MAGNETIC CONTACTOR, SIZE, COIL VOLTAGE AND NUMBER OF POLES AS INDICATED (L= LIGHTING CONTACTOR, P= POWER CONTACTOR) TIME SWITCH PHOTOCELL INDICATING LIGHT PUSH BUTTON STOP -START PUSH BUTTON CONTROL STATION ® HAND -OFF -AUTO PUSH BUTTON CONTROL STATION EH) MUSHROOM -TYPE PUSH BUTTON OVERHEAD PADDLE FAN N,IG N,IG N N, IG N N,IG N,IG E E E E E E PANELBOARD: LA (EXISTING) FAULT CURRENT: REFER TO ONE -LINE DIAGRAM EQUIPMENT GROUND BUS BUS AMPS: 100A AIC RATING: FCA +10% MINIMUM, FULLY RATED MAIN SIZE /TYPE: 100A MCB SERVES: SOLSTICE VOLTS /PHASE: 208Y/120V, 3PH, 4W MOUNTING: SURFACE SECTION: 1 LOCATION: STOCKROOM, ROOM #:101 CKT D DESCRIPTION V VOLTAMPS /PHASE W WIRE B BKR P P P P B BKR W WIRE V VOLTAMPS /PHASE D DESCRIPTION C CKT A B C N A B B C N 1 R RCPT -POS 3 360 % % / % %% /% 1 12 2 20 1 1 1 1 2 20 1 12 2 288 ; ;‘'%&''' Z Z %% L LTG - ETRANCE /EM LTG 2 2 3 R RCPT- CASHWRAP /� / 1 180 / / /// 1 12 2 20 1 1 1 1 2 20 1 12 / / X / /// 6 672 ' '/7///, L LTG-SALES DISPLAY (N) 4 4 5 R RCPT -DESK / /// /,%; % %/ %2' 5 540 1 12 2 20 1 1 1 1 2 20 1 12 / / /% // % %/ 'Z 6 672 L LTG -SALES DISPLAY (S) 6 6 7 R RCPT- COMPUTER 7 720 % % / / /// - -j /% 1 12 20 1 1 1 1 2 20 1 12 3 360 « « X., % %/� R RCPT -SHOW WINDOW 8 8 10 9 R RCPT - GENERAL ; ;/» j 1 1,080 y 11 R RCPT - SECURITY ' ' /' /j) j j/ //// / 360 1 12 2 20 1 1 1 1 2 20 1 12 j j /%%// / ///%1/� 1 156 L LTG - GENERAL SALES (S) 1 12 13 R RCPT -TMB 3 360 % %ii,/ / / 3 12 2 20 1 1 1 1 2 20 1 12 3 VOLTAGE DROP Leg 1 LL's Bus Duct to PNLBD -LA Value Wire size Sets of conductors Circuit Length, ft Conduit Type (S,P) Amps PF Circuit V_ oltage Phases (K) Theta Vdrop %Vdrop Cumulative %Vdrop 3 1 60 S 100 0.9 208 3 0.4510 2.61 1.25 1.25 N,LK N N EX N N N,LK N N N N N,LK N EX EX EX EX EX EX EX EX TENANT ELECTRICAL FEEDER LOAD SUMMARY TENANT OCCUPANCY TYPE: M FEEDER DESCRIPTION: TENANT SQUARE FOOTAGE: 731 208Y/120V, 3PH, 4W LOAD DESCRIPTION Connected Demand Demand KVA FACTOR KVA HVAC - SUMMER 3.64 100% 0.00 HVAC - WINTER 6.01 100% 6.01 LIGHTING (PER NEC -220) 2.90 125% 3.62 RECEPTACLES 3.78 100 %;50% 3.78 MOTOR LOADS 0.54 100% 0.54 LARGEST MOTOR LOAD 0.53 125% 0.66 SUPPLEMENTAL ELECTRIC HEAT 1.50 100% 1.50 MISCELLANEOUS EQUIPMENT 1.70 100% 1.70 DISPLAY CASE /SIGNAGE 1.20 125% 1.50 SHOW WINDOW / TRACK LIGHTING 2.60 PER NEC 3.25 TOTAL LOAD 24.39 KVA 22.56 TOTAL AMPACITY 67.71 AMPS 62.63 FEEDER AMPACITY 100 AMPS 100.00 SPARE CAPACITY AMPS 37 1. VERIFY EXISTING CONDITIONS PRIOR TO BID. 2. VERIFY EXACT REQUIREMENTS FROM LANDLORD PRIOR TO BEGINNING WORK. 3. VERIFY EXACT DISTANCES IN FIELD PRIOR TO BID. 4. COORDINATE WITH LANDLORD'S ELECTRICAL ENGINEER, ELECTRICIAN, AND THE LANDLORD'S DESIGNATED REPRESENTATIVE FOR FINAL APPROVAL AND SUPERVISION OF FINAL CONNECTIONS TO LANDLORD'S SWITCHBOARD. 5. ALL ADDITIONAL CONDUIT AND CONDUCTOR NEEDED FOR CONNECTION TO LANDLORDS ELECTRICAL SERVICE SHALL BE PROVIDED AND INSTALLED BY TENANTS ELECTRICAL CONTRACTOR. VERIFY ALL CONDITIONS IN FIELD PRIOR TO BID. 6. ELECTRICAL CONTACTOR SHALL COORDINATE WITH LOCAL POWER COMPANY FOR ALL ELECTRICAL SERVICE AND METERING INFORMATION. CIRCUIT SCHEDULE: ALL CONDUCTOR SIZES ARE BASED ON 75 DEG C RATED TERMINATION AND COPPER CONDUCTORS WITH TYPE THHN /THWN -2 INSULATION. WHERE ALUMINUM CONDUCTORS ARE ALLOWED PER SPECIFICATIONS AND FOR TERMINATION OR INSULATION TYPES RATED LESS THAN 75 DEG C, MODIFY SIZES ACCORDING TO NFPA 70. EXIST EXISTING TO REMAIN PARTIAL -X I ST \G B�S GTT -R O EXISTING NEUTRAL BUS A EXIST I ( EXISTING GROUND BUS EXIST TO GROUND BAR AT MAIN TELEPHONE BOARD (TTB) TO STRUCTURAL STEEL s TO ABOVE GROUND METAL PIPING s TO WATER SERVICE s TO BUILDING FOOTING (LIFER) • } • • • cn 1- V) 1- w w X w TO GROUND ROD(S) I 1 w 208Y/120V 30 4W LANLDORD ELECTRIC ROOM EXISTING AIC ( 1,/11 EXISTING METER TO REMAIN EXISTING FCA 1.25 %CVD� 60 FEET EXISTING 100A DISCONNECT PROVIDE NEW 100A LPN -RK5 FUSES. caJ Vm J wo ED ELECTRICAL ONE -LINE NO SCALE TENANT CONTRACTOR SHALL ROUTE (1) #8 ISOLATED GROUND FROM TENANT SPACE BACK TO LANDLORD EXISTING BUILDING GROUND. TENANT CONTRACTOR SHALL PROVIDE AND INSTALL NEW ISOLATED GROUND BUS BAR IN EXISTING PANEL BOARD 'LA'. REVIEWED FOR CODE. COMPLIANCE 1�p - NEC � MAY 1 b 2008 , City Of Tukwila UILDI ,DWI RECEIVED CITY OFTUKIViL? MAY i13 2006 PERM x CEN C +- LOB5Wo ,JHENDERSON ENGINEERS 8325 LENEXA DRIVE LENEXA, KS 66214 TEL 913 742 5000 FAX 913 742 5001 www.hei- eng.com 0750002188 RSP Architects 502 S. College Avenue Suite 203 Tempe, AZ 85281 Certification 480.889.2000 480.889.2099 fax www.rsparch.com RSP Architects, Ltd. with Terry Wobken Washington No. 6634 Location Westfield Southcenter 201 Southcenter Mall Tukwila, WA 98188 Project For Project No. Drawn By 1688.005.02 KH C Checked By C L D ate 05.06.08 NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of ASP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright ASP Architects 2003. All rights reserved. SCHEDULES, LEGENDS, AND DIAGRAMS E201 1. VERIFY EXISTING CONDITIONS PRIOR TO BID. 2. VERIFY EXACT REQUIREMENTS FROM LANDLORD PRIOR TO BEGINNING WORK. 3. VERIFY EXACT DISTANCES IN FIELD PRIOR TO BID. 4. COORDINATE WITH LANDLORD'S ELECTRICAL ENGINEER, ELECTRICIAN, AND THE LANDLORD'S DESIGNATED REPRESENTATIVE FOR FINAL APPROVAL AND SUPERVISION OF FINAL CONNECTIONS TO LANDLORD'S SWITCHBOARD. 5. ALL ADDITIONAL CONDUIT AND CONDUCTOR NEEDED FOR CONNECTION TO LANDLORDS ELECTRICAL SERVICE SHALL BE PROVIDED AND INSTALLED BY TENANTS ELECTRICAL CONTRACTOR. VERIFY ALL CONDITIONS IN FIELD PRIOR TO BID. 6. ELECTRICAL CONTACTOR SHALL COORDINATE WITH LOCAL POWER COMPANY FOR ALL ELECTRICAL SERVICE AND METERING INFORMATION. CIRCUIT SCHEDULE: ALL CONDUCTOR SIZES ARE BASED ON 75 DEG C RATED TERMINATION AND COPPER CONDUCTORS WITH TYPE THHN /THWN -2 INSULATION. WHERE ALUMINUM CONDUCTORS ARE ALLOWED PER SPECIFICATIONS AND FOR TERMINATION OR INSULATION TYPES RATED LESS THAN 75 DEG C, MODIFY SIZES ACCORDING TO NFPA 70. EXIST EXISTING TO REMAIN PARTIAL -X I ST \G B�S GTT -R O EXISTING NEUTRAL BUS A EXIST I ( EXISTING GROUND BUS EXIST TO GROUND BAR AT MAIN TELEPHONE BOARD (TTB) TO STRUCTURAL STEEL s TO ABOVE GROUND METAL PIPING s TO WATER SERVICE s TO BUILDING FOOTING (LIFER) • } • • • cn 1- V) 1- w w X w TO GROUND ROD(S) I 1 w 208Y/120V 30 4W LANLDORD ELECTRIC ROOM EXISTING AIC ( 1,/11 EXISTING METER TO REMAIN EXISTING FCA 1.25 %CVD� 60 FEET EXISTING 100A DISCONNECT PROVIDE NEW 100A LPN -RK5 FUSES. caJ Vm J wo ED ELECTRICAL ONE -LINE NO SCALE TENANT CONTRACTOR SHALL ROUTE (1) #8 ISOLATED GROUND FROM TENANT SPACE BACK TO LANDLORD EXISTING BUILDING GROUND. TENANT CONTRACTOR SHALL PROVIDE AND INSTALL NEW ISOLATED GROUND BUS BAR IN EXISTING PANEL BOARD 'LA'. REVIEWED FOR CODE. COMPLIANCE 1�p - NEC � MAY 1 b 2008 , City Of Tukwila UILDI ,DWI RECEIVED CITY OFTUKIViL? MAY i13 2006 PERM x CEN C +- LOB5Wo ,JHENDERSON ENGINEERS 8325 LENEXA DRIVE LENEXA, KS 66214 TEL 913 742 5000 FAX 913 742 5001 www.hei- eng.com 0750002188 RSP Architects 502 S. College Avenue Suite 203 Tempe, AZ 85281 Certification 480.889.2000 480.889.2099 fax www.rsparch.com RSP Architects, Ltd. with Terry Wobken Washington No. 6634 Location Westfield Southcenter 201 Southcenter Mall Tukwila, WA 98188 Project For Project No. Drawn By 1688.005.02 KH C Checked By C L D ate 05.06.08 NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of ASP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright ASP Architects 2003. All rights reserved. SCHEDULES, LEGENDS, AND DIAGRAMS E201 O:1 Solstice \0750002188 Solstice - South Center - Tukwila - WA \000 \Elec \0750002188E301.dwg, Plot, 5/8/2008 12:17:55 PM, kellyhyde, 1:1.00251 SECTION 16A GENERAL ELECTRICAL REQUIREMENTS: 16A 1 GENERAL INSTRUCTIONS 16A 1 -1 GENERAL REQUIREMENTS ALL REQUIREMENTS UNDER DIVISION 1 AND THE GENERAL AND SUPPLEMENTARY CONDITIONS OF THESE SPECIFICATIONS APPLY TO THIS SECTION AND DIVISION. WHERE THE REQUIREMENTS OF THIS SECTION AND DIVISION EXCEED THOSE OF DIVISION 1, THIS SECTION AND DIVISION TAKE PRECEDENCE. BECOME THOROUGHLY FAMILIAR WITH ALL THEIR CONTENTS AS TO REQUIREMENTS THAT AFFECT THIS DIVISION, SECTION OR BOTH. WORK REQUIRED UNDER THIS DIVISION INCLUDES ALL MATERIAL, EQUIPMENT, APPLIANCES, AND LABOR REQUIRED TO COMPLETE THE ENTIRE ELECTRICAL SYSTEM AS REQUIRED BY THE DRAWINGS AND SPECIFICATIONS, OR REASONABLY INFERRED TO BE NECESSARY TO FACILITATE EACH SYSTEM'S FUNCTIONING AS IMPLIED BY THE DESIGN AND THE EQUIPMENT SPECIFIED. THE SPECIFICATIONS AND DRAWINGS FOR THE PROJECT ARE COMPLEMENTARY, AND PORTIONS OF THE WORK DESCRIBED IN ONE, SHALL BE PROVIDED AS IF DESCRIBED IN BOTH. IN THE EVENT OF DISCREPANCIES, NOTIFY THE ENGINEER AN REQUEST CLARIFICATION PRIOR TO PROCEEDING WITH THE WORK INVOLVED. DRAWINGS ARE GRAPHIC REPRESENTATIONS OF THE WORK UPON WHICH THE CONTRACT IS BASED. THEY SHOW THE MATERIALS AND THEIR RELATIONSHIP TO ONE ANOTHER, INCLUDING SIZES, SHAPES, LOCATIONS, AND CONNECTIONS. THEY ALSO CONVEY THE SCOPE OF WORK, INDICATING THE INTENDED GENERAL ARRANGEMENT OF THE EQUIPMENT, FIXTURES, OUTLETS AND CIRCUITS WITHOUT SHOWING ALL OF THE EXACT DETAILS AS TO ELEVATIONS, OFFSETS, CONTROL LINES, AND OTHER INSTALLATION REQUIREMENTS. USE THE DRAWINGS AS A GUIDE WHEN LAYING OUT THE WORK AND TO VERIFY THAT MATERIALS AND EQUIPMENT WILL FIT INTO THE DESIGNATED SPACES, AND WHICH, WHEN INSTALLED PER MANUFACTURERS' REQUIREMENTS, WILL ENSURE A COMPLETE, COORDINATED, SATISFACTORY AND PROPERLY OPERATING SYSTEM. DRAWINGS ARE SCHEMATIC IN NATURE, SHOW THE VARIOUS COMPONENTS OF THE SYSTEMS APPROXIMATELY TO SCALE AND ATTEMPT TO INDICATE HOW THEY SHALL BE INTEGRATED WITH OTHER PARTS OF THE WORK. FIGURED DIMENSIONS TAKE PRECEDENCE TO SCALED DIMENSIONS. DETERMINE EXACT LOCATIONS BY JOB MEASUREMENTS, BY CHECKING THE REQUIREMENTS OF OTHER TRADES, AND BY REVIEWING ALL CONTRACT DOCUMENTS. CORRECT ERRORS THAT COULD HAVE BEEN AVOIDED BY PROPER CHECKING AND INSPECTION, AT NO ADDITIONAL COST TO THE OWNER. SPECIFICATIONS DEFINE THE QUALITATIVE REQUIREMENTS FOR PRODUCTS, MATERIALS, AND WORKMANSHIP UPON WHICH THE CONTRACT IS BASED. 16A 1 -2 DEFINITIONS WHENEVER USED IN THESE SPECIFICATIONS OR DRAWINGS, THE FOLLOWING TERMS SHALL HAVE THE INDICATED MEANINGS: 16A 1 -7 ORDINANCES, CODES, AND STANDARDS COMPLY, AT A MINIMUM, WITH NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) STANDARDS, STATE AND LOCAL BUILDING CODES, AND ALL OTHER APPLICABLE CODES AND ORDINANCES FOR PERFORMANCE, WORKMANSHIP, EQUIPMENT, AND MATERIALS. ADDITIONALLY, COMPLY WITH RULES AND REGULATIONS OF PUBLIC UTILITIES AND MUNICIPAL DEPARTMENTS AFFECTED BY CONNECTION OF SERVICES. WHERE CONFLICTS BETWEEN VARIOUS CODES, ORDINANCES, RULES, AND REGULATIONS EXIST, COMPLY WITH THE MOST STRINGENT. WHEREVER REQUIREMENTS OF THESE SPECIFICATIONS, DRAWINGS, OR BOTH, EXCEED THOSE OF THE ABOVE ITEMS, THE REQUIREMENTS OF THESE SPECIFICATIONS, DRAWINGS, OR BOTH, SHALL GOVERN. CODE COMPLIANCE, AT A MINIMUM, IS MANDATORY. CONSTRUE NOTHING IN THESE CONSTRUCTION DOCUMENTS AS PERMITTING WORK NOT IN COMPLIANCE, AT A MINIMUM, WITH THESE CODES. PROMPTLY BRING ALL CONFLICTS OBSERVED BETWEEN CODES, ORDINANCES, RULES, REGULATIONS, REFERENCED STANDARDS, AND THESE DOCUMENTS TO THE D ENGINEER'S ATTENTION FOR FINAL RESOLUTION. CONTRACTOR WILL BE HELD RESPONSIBLE FOR ANY VIOLATION OF THE LAW. FURNISH: "TO SUPPLY AND DELIVER TO THE PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLING, INSTALLING, AND SIMILAR OPERATIONS." INSTALL: "TO PERFORM ALL OPERATIONS AT THE PROJECT SITE, INCLUDING, BUT NOT LIMITED TO, AND AS REQUIRED: UNLOADING, UNPACKING, ASSEMBLING, ERECTING, PLACING, ANCHORING, APPLYING, WORKING TO DIMENSION, FINISHING, CURING, PROTECTING, CLEANING, TESTING, COMMISSIONING, STARTING UP AND SIMILAR OPERATIONS, COMPLETE, AND READY FOR THE INTENDED USE." PROVIDE: "TO FURNISH AND INSTALL COMPLETE, AND READY FOR THE INTENDED USE." FURNISHED BY OWNER (OR OWNER— FURNISHED) OR FURNISHED BY OTHERS: "AN ITEM FURNISHED BY THE OWNER OR UNDER OTHER DIVISIONS OR CONTRACTS, AND INSTALLED UNDER THE REQUIREMENTS OF THIS DIVISION, COMPLETE, AND READY FOR THE INTENDED USE, INCLUDING ALL ITEMS AND SERVICES INCIDENTAL TO THE WORK NECESSARY FOR PROPER INSTALLATION AND OPERATION. INCLUDE THE INSTALLATION UNDER THE WARRANTY REQUIRED BY THIS DIVISION. ENGINEER: WHERE REFERENCED IN THIS DIVISION, "ENGINEER" IS THE ENGINEER OF RECORD AND THE DESIGN PROFESSIONAL FOR THE WORK UNDER THIS DIVISION, AND IS A CONSULTANT TO, AND AN AUTHORIZED REPRESENTATIVE OF, THE ARCHITECT, AS DEFINED IN THE GENERAL AND /OR SUPPLEMENTARY CONDITIONS. WHEN USED IN THIS DIVISION, IT MEANS INCREASED INVOLVEMENT BY, AND OBLIGATIONS TO, THE ENGINEER, IN ADDITION TO INVOLVEMENT BY, AND OBLIGATIONS TO, THE "ARCHITECT ". AHJ: THE LOCAL CODE AND /OR INSPECTION AGENCY (AUTHORITY) HAVING JURISDICTION OVER THE WORK. NRTL: NATIONALLY RECOGNIZED TESTING LABORATORY, AS DEFINED AND LISTED BY OSHA IN 29 CFR 1910.7 (E.G., UL, ETL, CSA), AND ACCEPTABLE TO THE AHJ OVER THIS PROJECT. THE TERMS "APPROVED EQUAL ", "EQUIVALENT ", OR "EQUAL" ARE USED SYNONYMOUSLY AND SHALL MEAN "ACCEPTED BY OR ACCEPTABLE TO THE ENGINEER AS EQUIVALENT TO THE ITEM OR MANUFACTURER SPECIFIED ". THE TERM "APPROVED" SHALL MEAN LABELED, LISTED, CERTIFIED, OR ALL THREE, BY AN NRTL, AND ACCEPTABLE TO THE AHJ OVER THIS PROJECT. 16A 1 -3 PRE —BID SITE VISIT PERSONALLY INSPECT THE SITE OF THE PROPOSED WORK AND BECOME FULLY INFORMED OF CONDITIONS UNDER WHICH THE WORK IS TO BE DONE. FAILURE TO DO SO WILL NOT BE CONSIDERED SUFFICIENT JUSTIFICATION TO REQUEST OR OBTAIN EXTRA COMPENSATION OVER AND ABOVE THE CONTRACT PRICE. 16A 1 -4 MATERIAL AND WORKMANSHIP PROVIDE ALL MATERIAL AND EQUIPMENT NEW AND IN FIRST CLASS CONDITION. PROVIDE MARKINGS OR A NAMEPLATE FOR ALL MATERIAL AND EQUIPMENT IDENTIFYING THE MANUFACTURER AND PROVIDING SUFFICIENT REFERENCE TO ESTABLISH QUALITY, SIZE AND CAPACITY. ALL WORKMANSHIP SHALL BE OF THE FINEST POSSIBLE BY EXPERIENCED MECHANICS OF THE PROPER TRADE. IN GENERAL, PROVIDE THE FOLLOWING QUALITY GRADE(S) FOR ALL MATERIALS AND EQUIPMENT COMMERCIAL SPECIFICATION GRADE PROVIDE ALL HOISTS, SCAFFOLDS, STAGING, RUNWAYS, TOOLS, MACHINERY AND EQUIPMENT REQUIRED FOR THE PERFORMANCE OF THE ELECTRICAL WORK. STORE AND MAINTAIN MATERIAL AND EQUIPMENT IN CLEAN CONDITION, AND PROTECTED FROM WEATHER, MOISTURE, AND PHYSICAL DAMAGE. FURNISH ONLY MATERIAL AND EQUIPMENT THAT ARE LISTED, LABELED, CERTIFIED, OR ALL THREE, BY A NATIONALLY RECOGNIZED TESTING LABORATORY (NRTL), WHENEVER ANY LISTING OR LABELING EXISTS FOR THE TYPES OF MATERIAL AND EQUIPMENT SPECIFIED. AT A MINIMUM, GENERAL WORK PRACTICES FOR ELECTRICAL CONSTRUCTION SHALL BE IN ACCORDANCE WITH: NECA 1 (LATEST EDITION), "STANDARD PRACTICES FOR GOOD WORKMANSHIP IN ELECTRICAL CONSTRUCTION" 16A 1 -5 MANUFACTURERS IN OTHER ARTICLES WHERE LISTS OF MANUFACTURERS ARE INTRODUCED, SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE MANUFACTURERS SPECIFIED. WHERE A LIST IS PROVIDED, MANUFACTURERS ARE LISTED ALPHABETICALLY AND NOT IN ACCORDANCE WITH ANY RANKING OR PREFERENCE. WHERE MANUFACTURERS ARE NOT LISTED, PROVIDE PRODUCTS SUBJECT TO COMPLIANCE WITH REQUIREMENTS FROM MANUFACTURERS THAT HAVE BEEN ACTIVELY INVOLVED IN MANUFACTURING THE SPECIFIED PRODUCT FOR NO LESS THAN 5 YEARS. 16A 1 -6 COORDINATION COORDINATE ALL WORK WITH OTHER DIVISIONS AND TRADES SO THAT VARIOUS COMPONENTS OF THE ELECTRICAL SYSTEMS ARE INSTALLED AT THE PROPER TIME, FIT THE AVAILABLE SPACE, AND ALLOW PROPER SERVICE ACCESS TO ALL EQUIPMENT. REFER TO ALL DRAWINGS, INCLUDING, BUT NOT LIMITED T0, CIVIL, ARCHITECTURAL, STRUCTURAL, MECHANICAL, AND PLUMBING, AND TO RELEVANT EQUIPMENT SUBMITTALS AND SHOP DRAWINGS TO DETERMINE THE EXTENT OF CLEAR SPACES. MAKE ALL OFFSETS REQUIRED TO CLEAR EQUIPMENT, BEAMS AND OTHER STRUCTURAL MEMBERS, AND TO FACILITATE CONCEALING RACEWAYS IN THE MANNER ANTICIPATED IN THE DESIGN. PROVIDE MATERIALS WITH TRIM THAT WILL FIT PROPERLY THE TYPES OF CEILING, WALL, OR FLOOR FINISHES ACTUALLY INSTALLED. PROVIDE AND MAINTAIN ALL NECESSARY SIGNAL LIGHTS AND GUARDS FOR THE SAFETY OF THE PUBLIC. OBTAIN AND PAY FOR ALL PERMITS FOR WORK IN THIS DIVISION. 16A 1 -8 PROTECTION OF EQUIPMENT AND MATERIALS STORE AND PROTECT FROM DAMAGE EQUIPMENT AND MATERIALS DELIVERED TO JOB SITE, IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS. FOR MATERIALS AND EQUIPMENT SUSCEPTIBLE TO CHANGING WEATHER CONDITIONS, DAMPNESS, OR TEMPERATURE VARIATIONS, STORE INSIDE IN CONDITION SPACES. FOR MATERIALS AND EQUIPMENT NOT SUSCEPTIBLE TO THESE CONDITIONS, COVER WITH WATERPROOF, TEAR — RESISTANT, HEAVY TARP OR POLYETHYLENE PLASTIC AS REQUIRED TO PROTECT FROM PLASTER, DIRT, PAINT, WATER, OR PHYSICAL DAMAGE. EQUIPMENT AND MATERIAL THAT HAS BEEN DAMAGED BY CONSTRUCTION ACTIVITIES WILL BE REJECTED, AND CONTRACTOR SHALL FURNISH NEW EQUIPMENT AND MATERIAL OF A LIKE KIND. PLUG OR CAP OPEN ENDS OF CONDUITS WHILE STORED AND INSTALLED DURING CONSTRUCTION WHEN NOT IN USE TO PREVENT THE ENTRANCE OF DEBRIS INTO THE SYSTEMS. 16A 1 -9 SUBSTITUTIONS INCLUDE IN THE BASE BID THE PRODUCTS SPECIFICALLY NAMED IN THESE SPECIFICATIONS OR ON THE DRAWINGS. SUBMIT, IN THE FORM OF ALTERNATES, WITH BID, PRODUCTS OF ANY OTHER MANUFACTURERS FOR SIMILAR USE, PROVIDED THE DIFFERENCES IN COST, IF ANY, ARE INCLUDED FOR EACH PROPOSED ALTERNATE. PRIOR TO THE BID DATE, SUBSTITUTIONS WILL NOT BE CONSIDERED UNLESS SUBMITTED TO THE ARCHITECT, FOR ENGINEER'S REVIEW, AT LEAST TEN CALENDAR DAYS PRIOR TO THE DATE FOR RECEIPT OF BIDS. INCLUDE THE NAME OF THE MATERIAL OR EQUIPMENT FOR WHICH IT IS TO BE SUBSTITUTED AND A COMPLETE DESCRIPTION OF THE PROPOSED SUBSTITUTE INCLUDING CUTSHEETS, PHOTOMETRIC DATA, AND ALL OTHER INFORMATION NECESSARY FOR AN EVALUATION FOR EACH SUCH REQUEST. PROVIDE FACTORY GENERATED POINT —BY- POINT CALCULATIONS FOR ALL EXTERIOR LIGHT FIXTURES (PHOTOMETRIC FILES SUPPLIED SO THE ENGINEER CAN GENERATE A POINT —BY —POINT DO NOT SUFFICE FOR THE POINT —BY —POINT CALCULATIONS). PROVIDE INTERIOR POINT —BY —POINT CALCULATIONS AT THE DISCRETION OF THE ENGINEER. SUBMIT A $100.00 REVIEW FEE TO THE ENGINEER WITH EACH SUCH POINT —BY —POINT CALCULATION FOR USE OF ELECTRONIC BASE FILES. AFTER THE BID DATE, PROPOSALS TO SUBSTITUTE LIGHT FIXTURES FOR THOSE SHOWN ON THE DRAWINGS OR SPECIFIED HEREIN, WILL ONLY BE CONSIDERED AS A DEDUCT. SUBMIT PROPOSED SUBSTITUTIONS SEPARATELY, IN SUBMITTAL FORM, WITH A LIST OF PROPOSED SUBSTITUTIONS TOGETHER WITH A DEDUCT PRICE FOR EACH SUBSTITUTION. THE ARCHITECT, ENGINEER, OR BOTH, WILL THEN REVIEW PROPOSED SUBSTITUTIONS. THE ENGINEER WILL HAVE THE FINAL AUTHORITY AS TO WHETHER THE LIGHT FIXTURE IS AN ACCEPTABLE REPLACEMENT TO THE SPECIFIED ITEM. THE PROPOSED SUBSTITUTION MAY ALSO BE REJECTED BY THE ARCHITECT FOR AESTHETIC REASONS IF FELT NECESSARY OR DESIRABLE. IN THE EVENT THE PROPOSED SUBSTITUTIONS HEREIN DESCRIBED ARE REJECTED, FURNISH THE SPECIFIED ITEM. 16A 1 -10 SUBMITTALS ASSEMBLE AND SUBMIT TO THE ARCHITECT, FOR ENGINEER'S REVIEW, MANUFACTURERS' PRODUCT LITERATURE FOR MATERIAL AND EQUIPMENT TO BE FURNISHED, INSTALLED, OR BOTH, UNDER THIS DIVISION, INCLUDING SHOP DRAWINGS, MANUFACTURERS' PRODUCT DATA AND PERFORMANCE SHEETS, SAMPLES, AND OTHER SUBMITTALS REQUIRED BY THIS DIVISION. PROVIDE THE NUMBER OF SUBMITTALS REQUIRED BY DIVISION 1; HOWEVER, AT A MINIMUM, SUBMIT SEVEN (7) SETS. BEFORE SUBMITTING, VERIFY THAT ALL MATERIALS AND EQUIPMENT SUBMITTED ARE MUTUALLY COMPATIBLE AND SUITABLE FOR THE INTENDED USE, FIT THE AVAILABLE SPACES, AND ALLOW AMPLE AND CODE — REQUIRED ROOM FOR ACCESS AND MAINTENANCE. SUBMITTALS SHALL CONTAIN THE FOLLOWING INFORMATION. SUBMITTALS NOT SO IDENTIFIED WILL BE RETURNED TO THE CONTRACTOR WITHOUT ACTION: THE PROJECT NAME. THE APPLICABLE SPECIFICATION SECTION AND PARAGRAPH. THE SUBMITTAL DATE. THE CONTRACTOR'S STAMP, WHICH SHALL CERTIFY THAT THE STAMPED DRAWINGS HAVE BEEN CHECKED BY THE CONTRACTOR, COMPLY WITH THE DRAWINGS AND SPECIFICATIONS, AND HAVE BEEN COORDINATED WITH OTHER TRADES. TRANSMIT SUBMITTALS AS EARLY AS REQUIRED TO SUPPORT THE PROJECT SCHEDULE. ALLOW FOR TWO WEEKS ENGINEER REVIEW TIME, PLUS MAILING TIME, PLUS A DUPLICATION OF THIS TIME FOR RESUBMITTALS, IF REQUIRED. TRANSMIT SUBMITTALS AS SOON AS POSSIBLE AFTER NOTICE TO PROCEED AND BEFORE CONSTRUCTION STARTS. THE ENGINEER'S SUBMITTAL REVIEWS WILL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR ERRORS IN DIMENSIONS, DETAILS, SIZE OF MEMBERS, OR QUANTITIES; OR FOR OMITTING COMPONENTS OR FITTINGS; OR FOR NOT COORDINATING ITEMS WITH ACTUAL BUILDING CONDITIONS. 16A 1-11 ELECTRONIC DRAWING FILES IN PREPARATION OF SHOP DRAWINGS, CONTRACTOR MAY, AS AN OPTION, OBTAIN ELECTRONIC DRAWING FILES IN AUTOCAD OR DXF FORMAT FROM THE ENGINEER FOR A SHIPPING AND HANDLING FEE OF $200 FOR A DRAWING SET UP TO 12 SHEETS AND $15 PER SHEET FOR EACH ADDITIONAL SHEET. CONTACT THE ARCHITECT FOR WRITTEN AUTHORIZATION; AND, CONTACT THE ENGINEER TO OBTAIN THE NECESSARY RELEASE AGREEMENT FORM AND TO INDICATE THE DESIRED SHIPPING METHOD AND DRAWING FORMAT. IN ADDITION TO PAYMENT, ARCHITECT'S WRITTEN AUTHORIZATION AND ENGINEER'S RELEASE AGREEMENT FORM MUST BE RECEIVED BEFORE ELECTRONIC DRAWING FILES WILL BE SENT. 16A 1 -12 OPERATION AND MAINTENANCE INSTRUCTIONS SUBMIT TO THE ARCHITECT, FOR ENGINEER'S REVIEW, COPIES EACH OF OPERATIONS AND MAINTENANCE INSTRUCTION MANUALS, APPROPRIATELY BOUND INTO MANUAL FORM INCLUDING APPROVED COPIES OF THE FOLLOWING, REVISED IF NECESSARY TO SHOW SYSTEM AND EQUIPMENT AS ACTUALLY INSTALLED. PROVIDE THE NUMBER OF SUBMITTALS REQUIRED BY DIVISION 1; HOWEVER, AT A MINIMUM, SUBMIT THREE (3) SETS, AND INCLUDE, AT A MINIMUM, THE FOLLOWING INFORMATION: MANUFACTURERS' CATALOGS AND PRODUCT DATA SHEETS WIRING DIAGRAMS MAINTENANCE INSTRUCTIONS OPERATING INSTRUCTIONS PARTS LISTS TEST REPORTS AS DEFINED IN NETA ATS FOR THE SYSTEMS AND EQUIPMENT PROVIDED OR FURNISHED OR INSTALLED UNDER THIS CONTRACT. NAMES, ADDRESSES, TELEPHONE NUMBERS, AND E —MAIL ADDRESSES OF LOCAL CONTACTS FOR WARRANTEE SERVICES AND SPARE PARTS. SUBMIT MANUALS PRIOR TO REQUESTING THE FINAL PUNCH LIST AND BEFORE ANY REQUESTS FOR SUBSTANTIAL COMPLETION. ALSO PROVIDE ADEQUATE VERBAL INSTRUCTIONS OF SYSTEM OPERATIONS TO OWNER'S REPRESENTATIVE AT THE COMPLETION OF, AND BEFORE FINAL ACCEPTANCE OF, THE WORK. 16A 1 -13 TRAINING AT A TIME MUTUALLY AGREED UPON BETWEEN THE OWNER AND CONTRACTOR, PROVIDE THE SERVICES OF A FACTORY TRAINED AND AUTHORIZED REPRESENTATIVE TO TRAIN OWNER'S DESIGNATED PERSONNEL ON THE OPERATION AND MAINTENANCE OF THE EQUIPMENT PROVIDED FOR THIS PROJECT. PROVIDE TRAINING TO INCLUDE BUT NOT BE LIMITED TO AN OVERVIEW OF THE SYSTEM AND /OR EQUIPMENT AS IT RELATES TO THE FACILITY AS A 'NHOLE; OPERATION AND MAINTENANCE PROCEDURES AND SCHEDULES RELATED TO STARTUP AND SHUTDOWN, TROUBLESHOOTING, SERVICING, PREVENTIVE MAINTENANCE AND APPROPRIATE OPERATOR INTERVENTION; AND REVIEW OF DATA INCLUDED IN THE OPERATION AND MAINTENANCE INSTRUCTIONS. SUBMIT A CERTIFICATION LEIIER TO THE ARCHITECT STATING THAT THE OWNER'S DESIGNATED REPRESENTATIVE HAS BEEN TRAINED AS SPECIFIED HEREIN. LETTER SHALL INCLUDE DATE, TIME, ATTENDEES AND SUBJECT OF TRAINING. THE CONTRACTOR AND THE OWNER'S REPRESENTATIVE SHALL SIGN THE CERTIFICATION LETTER INDICATING AGREEMENT THAT THE TRAINING HAS BEEN PROVIDED. SCHEDULE TRAINING WITH OWNER WITH AT LEAST 7 DAYS' ADVANCE NOTICE. 16A 1 -14 WARRANTIES WARRANT EACH SYSTEM AND EACH ELEMENT THEREOF AGAINST ALL DEFECTS DUE TO FAULTY WORKMANSHIP, DESIGN OR MATERIAL FOR A PERIOD OF 12 MONTHS FROM DATE OF SUBSTANTIAL COMPLETION, UNLESS SPECIFIC ITEMS ARE NOTED TO CARRY A LONGER WARRANTY IN THE CONSTRUCTION DOCUMENTS OR MANUFACTURER'S STANDARD WARRANTY EXCEEDS 12 MONTHS. REMEDY ALL DEFECTS, OCCURRING WITHIN THE WARRANTY PERIOD(S), AS STATED IN THE GENERAL CONDITIONS AND DIVISION 1. ALSO WARRANT THE FOLLOWING ADDITIONAL ITEMS: ALL RACEWAYS ARE FREE FROM OBSTRUCTIONS, HOLES, CRUSHING, OR BREAKS OF ANY NATURE. ALL RACEWAY SEALS ARE EFFECTIVE. THE ENTIRE ELECTRICAL SYSTEM IS FREE FROM ALL SHORT CIRCUITS AND UNWANTED OPEN CIRCUITS AND GROUNDS. THE ABOVE WARRANTIES SHALL INCLUDE LABOR AND MATERIAL. MAKE REPAIRS OR REPLACEMENTS WITHOUT ANY ADDITIONAL COSTS TO THE OWNER. PERFORM THE REMEDIAL WORK PROMPTLY, UPON WRITTEN NOTICE FROM THE ENGINEER OR OWNER. AT THE TIME OF SUBSTANTIAL COMPLETION, DELIVER TO THE OWNER ALL WARRANTIES, IN WRITING AND PROPERLY EXECUTED, INCLUDING TERM LIMITS FOR WARRANTIES EXTENDING BEYOND THE ONE YEAR PERIOD, EACH WARRANTY INSTRUMENT BEING ADDRESSED TO THE OWNER AND STATING THE COMMENCEMENT DATE AND TERM. 16A 1 -15 MISCELLANEOUS REMODELING WORK PROVIDE ALL DEMOLITION OF EXISTING ELECTRICAL SYSTEMS AND NEW ELECTRICAL SYSTEM MODIFICATIONS REQUIRED BECAUSE OF BUILDING REMODELING, AS NOTED ON THE DRAWINGS, OR NECESSARY FOR PROPER OPERATION AND NEW CONSTRUCTION. REMOVE ALL ABANDONED CABLES AND WIRING ABOVE ACCESSIBLE CEILINGS AND VENTILATION SHAFTS. 16A 2 ELECTRICAL WORK 16A 2 -1 BUILDING OPERATION COMPLY WITH THE SCHEDULE OF OPERATIONS AS OUTLINED IN THE ARCHITECTURAL PORTIONS OF THIS SPECIFICATION. BUILDING SHALL BE IN CONTINUOUS OPERATION. ACCOMPLISH WORK THAT REQUIRES INTERRUPTION OF BUILDING OPERATION AT A TIME WHEN THE BUILDING IS NOT IN OPERATION, AND ONLY WITH WRITTEN APPROVAL OF BUILDING OWNER AND /OR TENANT. COORDINATE INTERRUPTION OF BUILDING OPERATION WITH THE OWNER AND /OR TENANT A MINIMUM OF 7 DAYS IN ADVANCE OF WORK. 16A 2 -3 COINCIDENTAL DAMAGE REPAIR ALL STREETS, SIDEWALKS, DRIVES, PAVING, WALLS, FINISHES, AND OTHER FACILITIES DAMAGED IN THE COURSE OF THIS WORK. REPAIR MATERIALS SHALL MATCH EXISTING CONSTRUCTION. ALL BACKFILLING AND REPAIRING SHALL MEET ALL REQUIREMENTS OF THE OWNER, CITY AND OTHERS HAVING JURISDICTION. REPAIR WORK SHALL BE THOROUGHLY FIRST CLASS. CONFORM TO ALL REQUIREMENTS OF DIVISION 2 OF THESE SPECIFICATIONS. 16A 2 -4 CUTTING AND PATCHING FOLLOWING THE REQUIREMENTS IN DIVISION 1, CUT WALLS, FLOORS, CEILINGS, AND OTHER PORTIONS OF THE FACILITY AS REQUIRED TO PERFORM WORK UNDER THIS DIVISION. OBTAIN PERMISSION OF THE ENGINEER, OWNER, OR BOTH, BEFORE DOING ANY CUTTING. CUT ALL HOLES AS SMALL AS POSSIBLE. PATCH WALLS, FLOORS, AND OTHER PORTIONS OF THE FACILITY AS REQUIRED BY WORK UNDER THIS DIVISION. ALL PATCHING SHALL BE THOROUGHLY FIRST CLASS AND SHALL MATCH THE ORIGINAL MATERIAL AND CONSTRUCTION, INCLUDING FIRE RATINGS IF APPLICABLE. 16A 2 -5 ROUGH —IN COORDINATE WITHOUT DELAY ALL ROUGHING —IN WITH OTHER DIVISIONS. CONCEAL ALL RACEWAYS EXCEPT IN UNFINISHED AREAS AND WHERE OTHERWISE INDICATED ON THE DRAWINGS. 16A 2 -6 SUPPORT SYSTEMS 1. STEEL SLOTTED SUPPORT SYSTEMS (SLOTTED CHANNEL): COMPLY WITH MFMA -3, FACTORY— FABRICATED COMPONENTS FOR FIELD ASSEMBLY; 12— GAUGE, 1 -5/8 —INCH BY 1 -5/8 —INCH; COOPER B —LINE, ERICO INTERNATIONAL CORPORATION, HILTI, INC., POWER— STRUT, THOMAS & BETTS CORPORATION, UNISTRUT. FINISHES: A. METALLIC COATINGS: HOT —DIP GALVANIZED AFTER FABRICATION AND APPLIED ACCORDING TO MFMA -3. 2. ALUMINUM SLOTTED SUPPORT SYSTEMS (SLOTTED CHANNEL): COMPLY WITH MFMA- 3, TYPE 6063 -16, PER ASTM B221; FACTORY— FABRICATED COMPONENTS FOR FIELD ASSEMBLY; 12— GAUGE, 1 -5/8 —INCH BY 1 -5/8 —INCH; COOPER B —LINE, ERICO INTERNATIONAL CORPORATION, HILTI, INC., POWER— STRUT, THOMAS & BETTS CORPORATION, UNISTRUT. FIELD FABRICATION: WHERE FIELD CUTTING OF STANDARD LENGTHS OF CHANNEL ARE REQUIRED, MAKE CUTS STRAIGHT AND PERPENDICULAR TO MANUFACTURED SURFACES. FOR FIELD —CUT OR DAMAGED SURFACES OF COATED CHANNELS, DRESS CUT ENDS, DAMAGED SURFACES, OR BOTH, WITH AN ABRASIVE MATERIAL (E.G., FILE, GRINDING STONE, OR SIMILAR) AND CLEANSER TO REMOVE OILS, RUST, SHARP EDGES AND SHARDS. FOR CHANNEL WITH A FACTORY— APPLIED COATING, RE— FINISH CUT EDGES WITH A COATING COMPATIBLE WITH THE FACTORY FINISH AND AS RECOMMENDED BY THE MANUFACTURER (E.G., MANUFACTURER'S TOUCH —UP PAINT OR ZINC —RICH COLD— GALVANIZING COMPOUND, AS APPLICABLE). 16A 2 -7 PENETRATIONS COORDINATE SLEEVE SELECTION AND APPLICATION WITH SELECTION AND APPLICATION OF FIRE — STOPPING SPECIFIED IN DIVISION 7 SECTION "THROUGH — PENETRATION FIRESTOP SYSTEMS." ROOFS: COORDINATE ALL ROOF PENETRATIONS WITH ENGINEER, OWNER, AND AS APPLICABLE, THE ROOFING CONTRACTOR PROVIDING A ROOF WARRANTY. KEEP ALL RACEWAY PENETRATIONS WITHIN MECHANICAL EQUIPMENT CURBS WHEREVER POSSIBLE. COORDINATE WITH DIVISION 15 WORK. FLASH AND COUNTERFLASH ALL OPENINGS THROUGH ROOF, AND /OR PROVIDE PRE- FABRICATED MOLDED SEALS COMPATIBLE WITH THE ROOF CONSTRUCTION INSTALLED, OR AS REQUIRED BY THE ENGINEER, OWNER, OR ROOFING CONTRACTOR. ALL ROOF PENETRATIONS SHALL BE LEAKTIGHT AT THE TERMINATION OF THE WORK AND SHALL NOT VOID ANY NEW OR EXISTING ROOF WARRANTIES. WALLS AND FLOORS: SLEEVES FOR RACEWAYS AND CABLES 1. STEEL PIPE SLEEVES: ASTM A 53/A 53M, TYPE E, GRADE B, SCHEDULE 40, GALVANIZED STEEL, PLAIN ENDS AND DRIP RINGS. 2. CAST —IRON PIPE SLEEVES: CAST OR FABRICATED "WALL PIPE," EQUIVALENT TO DUCTILE —IRON PRESSURE PIPE, WITH PLAIN ENDS AND INTEGRAL WATERSTOP, UNLESS OTHERWISE INDICATED. SLEEVES FOR RECTANGULAR OPENINGS: GALVANIZED SHEET STEEL WITH MINIMUM 0.138 INCH THICKNESS AND OF WIDTH AND LENGTH TO SUIT APPLICATION. 16B 2 -8 FIRE — STOPPING THROUGH PENETRATIONS FIRE — RESISTANT THROUGH PENETRATION SEALANTS: TWO —PART, FOAMED —IN- PLACE, SILICONE SEALANT FORMULATED FOR USE IN THROUGH — PENETRATION FIRE — STOPPING AROUND CABLES, RACEWAYS, AND CABLE TRAY PENETRATIONS THROUGH FIRE —RATED WALLS AND FLOORS. SEALANTS AND ACCESSORIES SHALL HAVE FIRE — RESISTANCE RATINGS INDICATED, AS ESTABLISHED BY TESTING IDENTICAL ASSEMBLIES IN ACCORDANCE WITH ASTM E 814, BY UNDERWRITERS' LABORATORIES, INC., OR OTHER NRTL ACCEPTABLE TO AHJ. ACCEPTABLE MANUFACTURERS: HILTI, INC. 3M CORP. RECTORSEAL. SPECIFY TECHNOLOGY INC. UNITED STATES GYPSUM COMPANY. SUBMITTALS SUBMIT PRODUCT DATA, MANUFACTURER'S SPECIFICATIONS AND TECHNICAL DATA FOR EACH MATERIAL INCLUDING THE COMPOSITION AND LIMITATIONS, DOCUMENTATION OF UL FIRESTOP SYSTEMS TO BE USED AND MANUFACTURER'S INSTALLATION INSTRUCTIONS TO COMPLY WITH DIVISION 1. MANUFACTURER'S ENGINEERING JUDGMENT IDENTIFICATION NUMBER AND DRAWING DETAILS WHEN NO UL SYSTEM IS AVAILABLE FOR AN APPLICATION. ENGINEERING JUDGMENT SHALL INCLUDE BOTH PROJECT NAME AND CONTRACTOR'S NAME WHO WILL INSTALL FIRESTOP SYSTEM AS DESCRIBED IN DRAWINGS. SUBMIT MATERIAL SAFETY DATA SHEETS PROVIDED WITH PRODUCT DELIVERED TO JOB —SITE. 16A 2 -9 ACCESS DOORS PROVIDE ACCESS DOORS IN CEILINGS AND WALLS, WHERE INDICATED OR REQUIRED FOR ACCESS OR MAINTENANCE TO CONCEALED EQUIPMENT INSTALLED UNDER THIS SECTION. PROVIDE CONCEALED HINGES, SCREWDRIVER —TYPE LOCK, AND ANCHOR STRAPS. MANUFACTURED BY MILCOR, ZURN, TITUS, OR EQUAL. OBTAIN ARCHITECT'S APPROVAL OF TYPE, SIZE, LOCATION AND COLOR BEFORE ORDERING. 16A 2 -10 EQUIPMENT FURNISHED BY OTHERS PROVIDE NECESSARY EQUIPMENT AND ACCESSORIES THAT ARE NOT PROVIDED BY THE EQUIPMENT SUPPLIER OR OWNER TO COMPLETE INSTALLATION OF EQUIPMENT FURNISHED BY OTHERS, IN LOCATIONS AS INDICATED ON THE DRAWINGS, SPECIFIED HEREIN, OR BOTH. EQUIPMENT AND ACCESSORIES NOT PROVIDED BY THE EQUIPMENT SUPPLIER MAY INCLUDE SUCH ITEMS AS FLEXIBLE CORDS AND PLUGS, AS REQUIRED FOR PROPER OPERATION OF THE COMPLETE SYSTEM, IN ACCORDANCE WITH THE MANUFACTURERS' INSTRUCTIONS. BE RESPONSIBLE FOR CORRECT ROUGH —IN DIMENSIONS, AND VERIFY THEM WITH ENGINEER, OWNER'S REPRESENTATIVE, EQUIPMENT SUPPLIER, OR ALL THREE, PRIOR TO ROUGH —IN AND SERVICE INSTALLATIONS. 16A 2 -11 CLEANING IN ADDITION TO THE REQUIREMENTS OF DIVISION 1, REMOVE FROM THE PREMISES DIRT AND REFUSE RESULTING FROM THE PERFORMANCE OF THE ELECTRICAL WORK, AS REQUIRED, TO PREVENT ACCUMULATION. COOPERATE IN MAINTAINING REASONABLY CLEAN PREMISES AT ALL TIMES. IMMEDIATELY PRIOR TO FINAL INSPECTION, MAKE A FINAL CLEANUP OF DIRT AND REFUSE RESULTING FROM THE WORK. CLEAN ALL MATERIAL AND EQUIPMENT INSTALLED UNDER THIS DIVISION. REMOVE DIRT, DUST, PLASTER, STAINS AND FOREIGN MATTER FROM ALL SURFACES. TOUCH UP AND RESTORE ALL DAMAGED FINISHES TO THEIR ORIGINAL CONDITION. 16A 2 -12 ADJUSTING, ALIGNING AND TESTING ADJUST, ALIGN, AND TEST ALL ELECTRICAL EQUIPMENT ON THIS PROJECT PROVIDED UNDER THIS DIVISION AND ALL ELECTRICAL EQUIPMENT FURNISHED BY OTHERS FOR INSTALLATION OR WIRING UNDER THIS DIVISION, FOR PROPER OPERATION. TEST ALL SYSTEMS AND EQUIPMENT ACCORDING TO THE REQUIREMENTS IN NETA ATS (LATEST EDITION) AND ALL ADDITIONAL REQUIREMENTS SPECIFIED IN FOLLOWING SECTIONS. MAINTAIN THE FOLLOWING ON THE PROJECT PREMISES AT ALL TIMES: A TRUE RMS READING VOLTMETER, A TRUE RMS READING AMMETER, AND A MEGOHMMETER INSULATION RESISTANCE TESTER. PROVIDE TEST DATA READINGS AS REQUESTED OR AS REQUIRED BY THE ENGINEER. 16A 2 -13 EQUIPMENT IDENTIFICATION PROVIDE EQUIPMENT IDENTIFICATION NAMEPLATES: ON ALL PANELBOARDS, SWITCHES, STARTERS, DIMMERS, SWITCHES IN DISTRIBUTION PANELBOARDS AND SWITCHBOARDS. NAMEPLATES: ENGRAVED, CONTRASTING COLOR, THREE — LAYER, LAMINATED PLASTIC INDICATING THE NAME OF THE EQUIPMENT, LOAD, OR CIRCUIT AS DESIGNATED ON THE DRAWINGS AND IN THE SPECIFICATIONS: SELF — ADHERING, WITH A PERMANENT, WEATHERPROOF ADHESIVE. ATTACHED WITH STAINLESS STEEL SCREWS AND HARDWARE. ATTACHMENT METHOD SHALL BE ACCEPTABLE TO THE MANUFACTURERS OF THE EQUIPMENT TO WHICH THE NAMEPLATES ARE BEING APPLIED. COLOR: BLACK BACKGROUND WITH WHITE LETTERS FOR NORMAL POWER; RED BACKGROUND WITH WHITE LETTERS FOR EMERGENCY POWER. LETTER HEIGHT: 1/4 —INCH MINIMUM. 16A 2 -14 SYSTEM START UP PRIOR TO STARTING UP THE ELECTRICAL SYSTEMS: 1. CHECK ALL COMPONENTS AND DEVICES. 2. LUBRICATE ITEMS ACCORDINGLY. 3. TIGHTEN SCREWS AND BOLTS FOR CONNECTORS AND TERMINALS ACCORDING TO MANUFACTURER'S PUBLISHED TORQUE— TIGHTENING VALUES. IF MANUFACTURER'S TORQUE VALUES ARE NOT INDICATED, USE THOSE SPECIFIED IN UL 486A AND UL 486B. 4. ADJUST TAPS ON EACH TRANSFORMER FOR RATED SECONDARY VOLTAGE WHEN THE TRANSFORMER IS AT MINIMUM LOAD. 5. CHECK AND RECORD BUILDING'S SERVICE ENTRANCE VOLTAGE, GROUNDING CONDITIONS, GROUNDING RESISTANCE, AND PROPER PHASING. 6. REPLACE ALL BURNED —OUT LAMPS AND LAMPS USED FOR TEMPORARY CONSTRUCTION LIGHTING IN PERMANENT LIGHT FIXTURES. 7. BALANCE ALL SINGLE —PHASE LOADS AT EACH PANELBOARD, REDISTRIBUTING BRANCH CIRCUIT CONNECTIONS UNTIL BALANCE IS ACHIEVED. DO NOT TYPE UP FINAL PANELBOARD DIRECTORIES UNTIL ALL RE— BALANCING AND REDISTRIBUTION OF CIRCUITS ARE COMPLETE. 8. AFTER ALL SYSTEMS HAVE BEEN INSPECTED AND ADJUSTED, CONFIRM ALL OPERATING FEATURES REQUIRED BY THE DRAWINGS AND SPECIFICATIONS AND MAKE FINAL ADJUSTMENTS AS NECESSARY. 16A 3 EXISTING EQUIPMENT REUSE AND REMOVAL REMOVE ALL EXISTING WIRING, LIGHT FIXTURES, EXPOSED CONDUITS AND OTHER ELECTRICAL INSTALLATIONS NOT REUSED PRIOR TO SUBSTANTIAL COMPLETION OF THE WORK. EXISTING RACEWAYS MAY BE REUSED IF THEIR POINTS OF TERMINATIONS ARE SUITABLE; IF THEY ARE CLEAN INSIDE WITH NO EVIDENCE OF RUST OR BURRS; IF FREE FROM CRACKS, FLATTENED SECTIONS OR SHARP BENDS; AND, IF SUITABLY LOCATED TO AVOID CONFLICTS WITH OTHER TRADES OR INSTALLATIONS. CAREFULLY "FISH" ALL EXISTING CONDUITS REUSED UNDER THIS CONTRACT TO REMOVE ALL DEBRIS AND OBSTRUCTIONS, AND SWAB UNTIL ALL MOISTURE IS REMOVED. CUT, PATCH, AND REPAIR WHERE REQUIRED FOR NEW ELECTRICAL INSTALLATIONS, AND PATCH AND REPAIR ALL SURFACE DAMAGE RESULTING FROM THIS WORK. CUT FLUSH WITH THE FLOOR AND PLUG AT BOTH ENDS, RACEWAYS STUBBED ABOVE THE FLOOR AND NOT USED AT SUBSTANTIAL COMPLETION OF THE WORK. RELOCATE ALL EXISTING ELECTRICAL SYSTEMS REQUIRED TO BE IN OPERATION AT SUBSTANTIAL COMPLETION OF THE CONTRACT, IF REQUIRED, AS A RESULT OF WORK INCLUDED UNDER THIS CONTRACT, EVEN IF NOT SPECIFICALLY INDICATED IN THE DRAWINGS OR SPECIFICATIONS. EXISTING SERVICE ENTRANCE CONDUCTORS AND FEEDER CONDUCTORS MAY BE REUSED IF ALL OF THE FOLLOWING CONDITIONS ARE MET: 1. CONDUCTOR SIZES MEET OR EXCEED THE SIZES SPECIFIED ON THE DRAWINGS. 2. CONDUCTOR INSULATION IS IN GOOD OR BETTER CONDITION. 3. CONDUCTOR INSULATION IS THE CORRECT TYPE FOR THE CONDITIONS. 16A 4 ALTERNATES INCLUDE ALL LABOR, MATERIALS, EQUIPMENT AND SERVICES NECESSARY FOR AND INCIDENTAL TO THE COMPLETION OF ALL WORK UNDER EACH PARTICULAR ALTERNATE. FURNISH SEPARATE BIDS FOR EACH APPLICABLE ALTERNATE, STATING THE AMOUNT TO BE ADDED TO OR DEDUCTED FROM THE BASE BID FOR EACH ALTERNATE ACCEPTED. APPLICABLE SECTIONS OF THE BASE SPECIFICATIONS APPLY TO ALL WORK REQUIRED BY THE ALTERNATES UNLESS OTHERWISE SPECIFIED. REFER TO THE ARCHITECTURAL PORTION OF THE SPECIFICATIONS FOR THE LIST OF ALTERNATES. END OF SECTION 16A REVIEWED FOR 016E COMPLIANCE l;p 0 -N C 1•ir`�iS .�. V 2N3 City-Of TukwtlE I p wypoN RECEIVED cf'ry OF TUKWII A MAY I13 MB Y'.f'diJii$ „s,1R1.L'• ELOB- 5 ‘qp HENDERSON ENGINEERS 8325 LENEXA DRIVE LENEXA, KS 66214 TEL 913 742 5000 FAX 913 742 5001 www.hei- eng.com 0750002188 RSP Architects 502 S. College Avenue Suite 203 Tempe, AZ 85281 Certification 480.889.2000 480.889.2099 fax www.rsparch.com S} j0 e„ RSP Architects, Ltd. with TerripAltihkao Washington No. 6634 Location Westfield Southcenter 201 Southcenter Mall Tukwila, WA 98188 Project For Project No. 1 688.005.02 Drawn By KH Checked By CL Date 05.06.08 NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of ASP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright ASP Architects 2003. All rights reserved. ELECTRICAL SPECIFICATIONS E301 O: \Solstice10750002188 Solstice - South Center - Tukwila - WA10001Elec\0750002188E302.dwg, Plot, 5/8/2008 12:17:23 PM, kellyhyde, 1:1.00251 SECTION 16B BASIC ELECTRICAL MATERIALS AND METHODS: 16B 1 METHODS 16B 1 -1 RACEWAYS METALLIC CONDUIT AND TUBING: ELECTRICAL METALLIC TUBING AND FITTINGS (EMT): ANSI C80.3, UL 797. REDUCED WALL EMT IS NOT ALLOWED. FLEXIBLE METAL CONDUIT (FMC): ZINC - COATED STEEL OR ALUMINUM, UL 1. REDUCED -WALL FMC IS NOT ALLOWED. INTERMEDIATE METAL CONDUIT (IMC): HOT -DIP GALVANIZED RIGID STEEL CONDUIT: ANSI C80.6, UL 1242. LIQUIDTIGHT FLEXIBLE METAL CONDUIT (LFMC): FLEXIBLE STEEL CONDUIT WITH PVC JACKET: UL 360 RIGID METAL CONDUIT (RMC): HOT -DIP GALVANIZED RIGID STEEL CONDUIT (GRS): ANSI C80.1, UL 6. PLASTIC- COATED IMC, RMC, AND FITTINGS: NEMA RN 1, UL LISTED. IMC AND RMC FITTINGS: NEMA FB 1; COMPATIBLE WITH CONDUIT TYPE AND MATERIAL, UL LISTED NON- METALLIC CONDUIT AND TUBING: RIGID NONMETALLIC CONDUIT (RNC): SCHEDULE 40 PVC, 90 DEG C RATED, NEMA TC- 2, UL 651; FITTINGS: NEMA TC 3, TC 6; UL 514, COMPATIBLE WITH CONDUIT /TUBING TYPE AND MATERIAL, UL LISTED. $ PT- 16B 1 -2 RACEWAY INSTALLATION ABOVE GROUND USE INSTALL ALL CIRCULAR RACEWAYS CONCEALED ABOVE SUSPENDED CEILINGS OR CONCEALED IN WALLS OR FLOORS WHEREVER POSSIBLE EXCEPT WHERE OTHERWISE INDICATED. PROVIDE GRS FOR ALL CONDUITS RUN EXPOSED TO WEATHER, OR EXPOSED TO OTHER HAZARDOUS CONDITIONS. ALL OTHER RACEWAY MAY BE EMT WHERE APPROVED BY LOCAL CODE. USE COMPRESSION TYPE FITTINGS FOR EMT, WITH ALL FITTINGS UL LISTED FOR THE ENVIRONMENT IN WHICH THEY ARE USED. UNDERGROUND USE PROVIDE GRS INSTALLED BELOW GRADE WITH A CORROSION RESISTANT BONDED - PLASTIC OR APPROVED MASTIC COATING. THIS SHALL INCLUDE THE 90- DEGREE ELBOW BELOW GRADE AND THE ENTIRE VERTICAL TRANSITION TO ABOVE GRADE. EQUIPMENT CONNECTIONS USE FMC FOR FINAL CONNECTION TO EACH MOTOR AND TRANSFORMER, AND TO ANY DEVICE THAT WOULD OTHERWISE TRANSMIT MOTION, VIBRATION, OR NOISE. USE LFMC WHERE EXPOSED TO LIQUIDS, VAPORS OR SUNLIGHT, AND TO CONNECT TO KITCHEN AND FOOD SERVICE EQUIPMENT. PROVIDE ALL FMC AND LFMC WITH AN INSULATED BONDING CONDUCTOR. USE ONLY METAL RACEWAYS FOR ALL POWER WIRING FROM THE OUTPUT OF VARIABLE FREQUENCY DRIVES TO THEIR RESPECTIVE MOTORS. GENERAL RACEWAY INSTALLATION REQUIREMENTS INSTALL RACEWAYS PARALLEL AND PERPENDICULAR TO BUILDING LINES. INSTALL RACEWAYS TO REQUIREMENTS OF STRUCTURE AND TO REQUIREMENTS OF ALL OTHER WORK ON THE PROJECT; TO CLEAR ALL OPENINGS, DEPRESSIONS, PIPES, DUCTS, REINFORCING STEEL, AND OTHER IMMOVABLE OBSTACLES. INSTALL RACEWAYS SET IN FORMS FOR CONCRETE STRUCTURE IN SUCH A MANNER THAT INSTALLATION WILL NOT AFFECT THE STRENGTH OF THE STRUCTURE. EXCEPT WHERE APPROVED IN WRITING BY THE ENGINEER, INSTALL NO RACEWAY IN A SLAB -ON- GRADE. LOCATE RACEWAY BELOW GRANULAR FILL BELOW SLABS -ON- GRADE. INSTALL RACEWAYS CONTINUOUS BETWEEN CONNECTIONS TO OUTLETS, BOXES AND CABINETS WITH A MINIMUM POSSIBLE NUMBER OF BENDS AND NOT MORE THAN THE EQUIVALENT OF FOUR 90- DEGREE BENDS BETWEEN CONNECTIONS. USE MANUFACTURED ELBOWS FOR ALL 45- AND 90- DEGREE BENDS, UNLESS APPROVED BY THE ENGINEER IN ADVANCE. MAKE OTHER BENDS SMOOTH AND EVEN AND WITHOUT FLATTENING RACEWAY OR FLAKING GALVANIZING OR ENAMEL. RADII OF BENDS SHALL BE AS LONG AS POSSIBLE AND NEVER SHORTER THAN THE CORRESPONDING TRADE ELBOW. USE LONG RADIUS ELBOWS FOR ALL UNDERGROUND INSTALLATIONS, WHERE NECESSARY OR INDICATED. SECURELY FASTEN RACEWAYS IN PLACE WITH APPROVED STRAPS, HANGERS AND STEEL SUPPORTS AS REQUIRED. ATTACH RACEWAY SUPPORTS TO THE BUILDING STRUCTURE. HANG SINGLE RACEWAYS FOR FEEDERS WITH MALLEABLE SPLIT RING HANGERS WITH ROD AND TURNBUCKLE SUSPENSION FROM INSERTS SPACED NOT OVER 10 FEET APART IN CONSTRUCTION ABOVE. CLAMP GROUPS OF HORIZONTAL FEEDER RACEWAYS TO STEEL CHANNELS THAT ARE SUSPENDED FROM INSERTS SPACED NOT OVER 10 FEET APART IN CONSTRUCTION ABOVE. SECURELY CLAMP VERTICAL FEEDER RACEWAYS TO STRUCTURAL STEEL MEMBERS ATTACHED TO STRUCTURE. INSTALL CABLE CLAMPS FOR SUPPORT OF VERTICAL FEEDERS WHERE REQUIRED. ADD RACEWAY SUPPORTS WITHIN 12 INCHES OF ALL BENDS, ON BOTH SIDES OF THE BENDS. DO NOT SUPPORT RACEWAYS FROM SUSPENDED CEILING COMPONENTS. REAM RACEWAY ENDS, THOROUGHLY CLEAN RACEWAYS BEFORE INSTALLATION, AND KEEP CLEAN AFTER INSTALLATION. PLUG OR COVER OPENINGS AND BOXES AS REQUIRED TO KEEP RACEWAYS CLEAN DURING CONSTRUCTION AND FISH ALL RACEWAYS CLEAR OF OBSTRUCTIONS BEFORE PULLING CONDUCTORS WIRES. PROVIDE RACEWAYS OF AMPLE SIZE FOR PULLING OF WIRE AND NOT SMALLER THAN CODE REQUIREMENTS AND NOT LESS THAN 1/2 -INCH IN SIZE, UNLESS INDICATED OTHERWISE ON DRAWINGS. PROTECT ALL RACEWAY INSTALLATIONS AGAINST DAMAGE DURING CONSTRUCTION. REPAIR ALL RACEWAYS DAMAGED OR MOVED OUT OF LINE AFTER ROUGHING -IN TO MEET ENGINEER'S APPROVAL WITHOUT ADDITIONAL COST TO THE OWNER. ALIGN AND INSTALL TRUE AND PLUMB ALL RACEWAY TERMINATIONS AT PANELBOARDS, SWITCHBOARDS, MOTOR CONTROL EQUIPMENT AND JUNCTION BOXES. INSTALL APPROVED EXPANSION /DEFLECTION FITTINGS WHERE RACEWAYS PASS THROUGH (IF EMBEDDED) OR ACROSS (IF EXPOSED) EXPANSION JOINTS. ALSO WHEN USING RNC OR RAC IN EXPOSED ENVIRONMENTS IN ACCORDANCE WITH THE NEC AND EXPANSION /CONTRACTION PROPERTIES OF RNC OR RAC. INSTALL A PULL WIRE IN EACH EMPTY RACEWAY THAT IS LEFT FOR INSTALLATION OF CONDUCTORS OR CABLES UNDER OTHER DIVISIONS OR CONTRACTS. USE POLYPROPYLENE OR MONOFILAMENT PLASTIC LINE WITH NOT LESS THAN 200 -LB TENSILE STRENGTH. LEAVE AT LEAST 24 INCHES OF SLACK AT EACH END OF PULL WIRE. MAKE ALL JOINTS AND CONNECTIONS IN A MANNER THAT WILL ENSURE MECHANICAL STRENGTH AND ELECTRICAL CONTINUITY. EFFECTIVELY SEAL RACEWAYS, BY INSTALLING A CONDUIT FITTING AT THE BOUNDARY OF THE TWO SPACES, AND FILLING IT WITH AN APPROVED PLIABLE MATERIAL, AFTER CONDUCTORS OR CABLES HAVE BEEN INSTALLED AND TESTED, WHEN EVER: RACEWAYS PASS FROM NON- COOLED TO COOLED SPACES. RACEWAYS TRANSITION FROM OUTSIDE A FACILITY OR ENCLOSURE TO INSIDE, WHETHER BURIED OR EXPOSED. 16B 1 -3 BUSHINGS AND LOCKNUTS RIGIDLY TERMINATE CONDUITS ENTERING SHEET METAL ENCLOSURES TO THE ENCLOSURE WITH A BUSHING AND LOCKNUT ON THE INSIDE AND A LOCKNUT OR AN APPROVED HUB ON THE OUTSIDE. CONDUIT SHALL ENTER THE ENCLOSURE SQUARELY. PROVIDE BUSHINGS AND LOCKNUTS MADE OF GALVANIZED MALLEABLE IRON WITH SHARP, CLEAN -CUT THREADS. WHERE EMT ENTERS A BOX, PROVIDE APPROVED EMT COMPRESSION CONNECTORS. USE INSULATED, GROUNDING, OR COMBINATION, BUSHINGS WHEREVER CONNECTION IS SUBJECT TO VIBRATION OR MOISTURE, WHEN REQUIRED BY NFPA 70, OR BOTH. 16B 1 -4 CONDUCTORS AND CABLES CONDUCTOR MATERIAL: 1. ANNEALED (SOFT) COPPER COMPLYING WITH ICEA S -95- 658 /NEMA WC70; A. SOLID CONDUCTOR FOR NO. 10 AWG AND SMALLER; CONCENTRIC, COMPRESSED STRANDED FOR NO. 8 AWG AND LARGER 2. CONDUCTOR INSULATION TYPES: 90- DEGREE C- RATED, TYPE THHN /THWN -2 OR XHHW -2 COMPLYING WITH ICEA S -95- 658 /NEMA WC70. 3. SIZES OF CONDUCTORS AND CABLES INDICATED OR SPECIFIED ARE IN AMERICAN WIRE GAGE (AWG - BROWN AND SHARPE). 4. UNLESS INDICATED OTHERWISE, SPECIAL PURPOSE CONDUCTORS AND CABLES, SUCH AS LOW VOLTAGE CONTROL AND SHIELDED INSTRUMENT WIRING, SHALL BE AS RECOMMENDED BY THE SYSTEM EQUIPMENT MANUFACTURER. ALL FEEDER AND BRANCH CIRCUIT CONDUCTORS NO. 8 AWG AND LARGER: STRANDED, TYPE THWN -2 OR XHHW -2 INSULATION. ALL CONDUCTORS, NO. 10 AWG AND SMALLER, USED FOR POWER AND LIGHTING CIRCUITS: SOLID COPPER, TYPE THWN -2 (WET OR DAMP LOCATIONS, OR IN CONDUIT BELOW GRADE OR SLAB), TYPE THHN (DRY LOCATIONS ONLY AND ABOVE GRADE) INSULATION, OR DUAL -RATED TYPE THHN /THWN -2. ALL BRANCH CIRCUIT WIRING: NOT SMALLER THAN NO. 12 AWG. IF NO CONDUCTOR SIZE IS INDICATED ON THE DRAWINGS FOR A BRANCH CIRCUIT, PROVIDE CONDUCTORS AND CONDUIT SIZED PER NFPA 70 AND BASED ON THE INDICATED BRANCH CIRCUIT OVERCURRENT PROTECTIVE DEVICE (OCPD) RATING AND NUMBER OF POLES. WHERE NO CIRCUIT SIZE (I.E., CONDUCTORS AND OCPD) IS INDICATED ON THE DRAWINGS FOR A BRANCH CIRCUIT, PROVIDE THREE NO. 12 AWG CONDUCTORS, IN 3/4 -INCH RACEWAY, AND A 20A CIRCUIT BREAKER. CONDUCTORS FIELD - INSTALLED WITHIN FLUORESCENT LIGHT FIXTURE CHANNELS: TYPE THHN. CONTROL WIRING: STRANDED COPPER CONDUCTORS, 600V INSULATION, OF THE PROPER TYPE, SIZE AND NUMBER AS REQUIRED TO ACCOMPLISH SPECIFIED FUNCTION. MINIMUM SIZE: NO. 14 AWG, UNLESS NOTED OTHERWISE. TYPE MC CABLE: 600V, UNJACKETED; ANSI E119 AND E814, UL STANDARDS 44 OR 83 (AS APPLICABLE), AND 1569, NFPA 70 ARTICLE 330; ALUMINUM OR GALVANIZED STEEL INTERLOCKED ARMOR; THHN- OR XHHW - INSULATED CONDUCTORS; COLOR CODE: ICEA METHOD 1, WITH GREEN INSULATED GROUNDING CONDUCTOR 16B 1 -5 INSTALLATION OF CONDUCTORS AND CABLES INSTALL ALL WIRING IN APPROVED RACEWAY AND ENCLOSURES. SUPPORT ALL CONDUCTORS AND CABLES IN VERTICAL INSTALLATIONS, AS REQUIRED BY NFPA 70, BY INSTALLING CABLE SUPPORTS OR PLUG -TYPE CONDUIT RISER SUPPORTS, OR WIRE -MESH SAFETY GRIPS. INSTALL ALL CONDUCTORS AND CABLE IN RACEWAYS CONTINUOUS WITHOUT TAPS OR SPLICES. SPLICE OR TAP ONLY IN APPROVED BOXES AND ENCLOSURES WITH APPROVED SOLDERLESS CONNECTORS, OR CRIMP CONNECTORS AND TERMINAL BLOCKS FOR CONTROL WIRING, AND KEEP TO THE MINIMUM REQUIRED. INSULATE ALL SPLICES, TAPS, AND JOINTS AS REQUIRED BY CODES. ALL MATERIALS USED TO TERMINATE, SPLICE OR TAP CONDUCTORS: DESIGNED FOR, PROPERLY SIZED FOR, AND UL LISTED FOR THE SPECIFIC APPLICATION AND CONDUCTORS INVOLVED, AND INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, USING THE MANUFACTURER'S RECOMMENDED TOOLS. WHERE WIRING IS INDICATED AS INSTALLED, BUT THE CONNECTION IS INDICATED "FUTURE" OR "BY OTHER DIVISION, TRADES, OR CONTRACTS ", LEAVE A MINIMUM 3- FOOT "PIGTAIL" AT THE BOX, TAPE THE ENDS OF THE CONDUCTORS, AND COVER THE BOX. THE NUMBER OF CONDUCTORS IN A SPECIFIC RACEWAY "HOME RUN" IS INDICATED WITH CROSS LINES (TICK MARKS) ON EACH "CIRCUIT RUN" ON THE DRAWINGS. IN GENERAL, THE DIRECTION OF BRANCH CIRCUIT "HOME RUN" ROUTING IS INDICATED ON THE DRAWINGS, COMPLETE WITH CIRCUIT NUMBERS AND PANELBOARD DESIGNATION. CONTINUE ALL SUCH "HOME RUN" WIRING TO THE DESIGNATED PANELBOARD, AS THOUGH "CIRCUIT RUNS" WERE INDICATED IN THEIR ENTIRETY. WHEN MULTIPLE HOME RUNS ARE COMBINED INTO A SINGLE RACEWAY SUCH THAT THE NUMBER OF CONDUCTORS EXCEEDS FOUR (CONDUCTOR COUNT IS MADE UP OF ANY COMBINATION OF PHASE AND NEUTRAL CONDUCTORS), THE FOLLOWING RESTRICTIONS APPLY, WHICH ARE IN ADDITION TO THOSE IN NFPA 70: 1. NORMAL OR NON- ESSENTIAL CIRCUITS. A. MAXIMUM OF 16 CONDUCTORS IN A SINGLE RACEWAY. FOR UP TO EIGHT CONDUCTORS IN A RACEWAY, MINIMUM RACEWAY SIZE: 3/4 -INCH. FOR GREATER THAN EIGHT CONDUCTORS, MINIMUM RACEWAY SIZE: 1 -INCH. DO NOT INSTALL ANY OTHER TYPE OF CIRCUIT IN THIS RACEWAY. B. THE MINIMUM WIRE SIZE FOR ALL CONDUCTORS IN THIS RACEWAY: NO. 10 AWG. C. ONLY 15A AND 20A BRANCH CIRCUIT HOMERUNS MAY BE COMBINED INTO ONE RACEWAY. 2. GFCI CIRCUITS. A. DO NOT USE MULTI - CONDUCTOR CIRCUITS, WITH A SHARED NEUTRAL, FOR ANY GFCI CIRCUIT BREAKER OR RECEPTACLE CIRCUIT. FOR BRANCH CIRCUITS FED FROM GFCI CIRCUIT BREAKERS, LIMIT THE ONE -WAY CONDUCTOR LENGTH TO 100 FEET BETWEEN THE PANELBOARD AND THE MOST REMOTE RECEPTACLE OR LOAD ON THE GFCI CIRCUIT. WIRING SHALL HAVE INSULATION OF THE PROPER COLOR TO MATCH COLOR CODE SYSTEM IN THE TABLE BELOW. IN LARGER SIZES, WHERE PROPERLY COLORED INSULATION IS NOT AVAILABLE, USE VINYL PLASTIC ELECTRICAL TAPE OF THE APPROPRIATE COLOR AROUND EACH CONDUCTOR AT ALL TERMINATION POINTS, JUNCTION AND PULL BOXES. System Voltage Conductor Type Color 208Y/120 Phase A Phase B Phase C Neutral Equipment Ground Isolated Ground Black Red Blue White Green Green w /yellow stripe TYPE MC CABLE MAY ONLY BE USED: 1. IN LIEU OF FLEXIBLE CONDUIT AND WIRING FROM LIGHT FIXTURES IN ACCESSIBLE CEILINGS TO JUNCTION BOXES (ATTACHED TO BUILDING STRUCTURE) ABOVE THE CEILING. PROVIDE CABLE WHIPS OF SUFFICIENT LENGTHS TO ALLOW FOR RELOCATING EACH LIGHT FIXTURE WITHIN A 5 -FOOT RADIUS OF ITS INSTALLED LOCATION, BUT NOT EXCEEDING 6 FEET IN UNSUPPORTED LENGTHS. 2. FOR VERTICAL DROPS IN STUD WALLS. 3. IN LIEU OF EMT, ONLY FOR 15A AND 20A BRANCH CIRCUITS (WITH UP TO FOUR CONDUCTORS, NOT INCLUDING GROUND CONDUCTOR), AND ONLY IN DRY CONCEALED LOCATIONS ABOVE GRADE, EXCEPT WHERE SPECIFICALLY NOT PERMITTED BY NFPA 70. 4. A. B. C. D. DO NOT USE MC CABLE FOR THE FOLLOWING: HOMERUNS TO PANELBOARDS. WHERE EXPOSED TO VIEW. WHERE EXPOSED TO DAMAGE. WET LOCATIONS. (4) E. WHEN RESTRICTED OTHERWISE ABOVE, AND WHEN SPECIFICALLY DISALLOWED BY THE LOCAL AHJ, LANDLORD, OR BOTH. PROPERLY IDENTIFY ALL TERMINAL BLOCKS AND WIRE TERMINALS FOR CONTROL WIRING WITH VINYL STICK -ON MARKERS OR EQUIVALENT. PROVICE ENGINEER WITH A LIST OF PROPOSED IDENTIFYING NUMBERS FOR REVIEW PRIOR TO INSTALLING MARKERS. PROVIDE AN EQUIPMENT - GROUNDING CONDUCTOR, OR BONDING JUMPER, AS APPLICABLE, IN ALL BRANCH CIRCUITS AND FEEDERS, SIZED IN ACCORDANCE WITH NFPA 70 TABLES 250.66 OR 250.122, AS APPLICABLE, UNLESS INDICATED AS LARGER ON THE DRAWINGS. VOLTAGE DROP IN BRANCH CIRCUITS SHALL NOT EXCEED 3 PERCENT. 16B 1 -6 JUNCTION BOXES, PULL BOXES, CABINETS AND WIREWAYS PROVIDE JUNCTION BOXES, PULL BOXES, CABINETS AND WIREWAYS WHEREVER NECESSARY FOR PROPER INSTALLATION OF VARIOUS ELECTRICAL SYSTEMS ACCORDING TO NFPA 70 AND WHERE INDICATED ON THE DRAWINGS. SIZE AS REQUIRED FOR THE SPECIFIC FUNCTION OR AS REQUIRED BY NFPA 70, WHICHEVER IS LARGER. CONSTRUCTION SHALL BE OF A NEMA DESIGN SUITABLE FOR THE ENVIRONMENT INSTALLED. JUNCTION BOXES INSTALLED BEHIND WALL CASES, AND IN OR ON OTHER STORE FIXTURES, EXCEPT WHERE OTHERWISE SPECIFIED, SHALL BE 4 -INCH SQUARE OR LARGER, WITH GALVANIZED COVERS. HORIZONTALLY MOUNT JUNCTION BOXES UNDER CENTER FIXTURES (AND CASES), HANDY BOXES OR 4 -INCH SQUARE BOXES WITH TOPS OF BOXES NOT MORE THAN 3- 1 /2 INCHES ABOVE THE FLOOR. SIZE JUNCTION BOXES TO ADEQUATELY CONTAIN ALL REQUIRED CONDUCTORS AND SPLICES. 16B 1 -7 OUTLET BOXES ALL OUTLETS INCLUDING LIGHT FIXTURE, SWITCH, RECEPTACLE, AND SIMILAR OUTLETS: NATIONAL ELECTRICAL, APPLETON, STEEL CITY, RACO, OR APPROVED EQUAL, GALVANIZED STEEL KNOCKOUT BOXES, SUITABLE IN DESIGN TO THE PURPOSE THEY SERVE AND THE SPACE THEY OCCUPY. SIZE AS REQUIRED FOR THE SPECIFIC FUNCTION OR AS REQUIRED BY NFPA 70, WHICHEVER 15 LARGER. SET ALL OUTLET BOXES IN WALLS, COLUMNS, FLOORS, OR CEILINGS SO THEY ARE FLUSH WITH THE FINISHED SURFACE, ACCURATELY SET, AND RIGIDLY SECURED IN POSITION. PROVIDE PLASTER RINGS, EXTENSION RINGS AND /OR MASONRY RINGS AS REQUIRED FOR FLUSH MOUNTING. PROVIDE APPROVED CAST OUTLET BOXES, WITH HUBS AND WEATHERPROOF COVERS, IN ALL AREAS SUBJECT TO DAMP, WET, OR HARSH CONDITIONS. 16B 1 -8 OUTLET LOCATIONS COORDINATE LOCATIONS OF OUTLET BOXES. OUTLETS ARE ONLY APPROXIMATELY LOCATED ON THE SMALL SCALE DRAWINGS. USE GREAT CARE IN THE ACTUAL LOCATION BY CONSULTING THE VARIOUS LARGE SCALE DETAILED DRAWINGS USED BY OTHER DIVISION TRADES, AND BY SECURING DEFINITE LOCATIONS FROM THE ARCHITECT. 16B 1 -9 MOUNTING HEIGHTS UNLESS NOTED OTHERWISE, INSTALL WIRING DEVICES AS INDICATED BELOW (NOTE: ALL DIMENSIONS ARE TO THE BOTTOM OF THE OUTLET BOX UNLESS NOTED OTHERWISE): RECEPTACLES: 1. GENERAL: A. VERTICALLY WITH THE GROUND SLOT MOUNTED AT THE BOTTDM: 16 INCHES ABOVE FINISHED FLOOR. 2. ABOVE COUNTERS: A. FOR 36 -INCH HIGH COUNTER TOPS: 44 INCHES ABOVE FINISHED FLOOR, VERTICALLY. B. FOR 34 -INCH HIGH COUNTER TOPS: 40 INCHES ABOVE FINISHED FLOOR, VERTICALLY. 3. WEATHERPROOF EXTERIOR RECEPTACLES: 24 INCHES ABOVE FINISHED GRADE, VERTICALLY. 4. GFCI RECEPTACLES: SAME AS GENERAL RECEPTACLES. 5. ISOLATED GROUND RECEPTACLES: SAME AS GENERAL RECEPTACLES. SWITCHES: 1. GENERAL: 44 INCHES ABOVE FINISHED FLOOR. 2. ABOVE COUNTERS: SAME AS FOR RECEPTACLES. TELEPHONE /DATA OUTLET BOXES: 1. GENERAL: MATCH MOUNTING HEIGHT OF ADJACENT WIRING DEVICE LISTED ABOVE. 2. WALL - MOUNTED TELEPHONE: 40 INCHES ABOVE FINISHED FLOOR. 3. FOR OTHER THAN WIRING DEVICES, REFER TO PARAGRAPHS, ARTICLES, SECTIONS, DIVISIONS, OR DRAWINGS TO OBTAIN MOUNTING HEIGHTS FOR SPECIFIC EQUIPMENT OR SYSTEMS. 16B 1 -10 WIRING DEVICES THE CATALOG NUMBERS LISTED FOR WIRING DEVICES ARE GENERALLY FOR 20A RATED DEVICES. WHERE 15A RATED DEVICES ARE INDICATED ON THE DRAWINGS OR REQUIRED FOR CIRCUIT RATING LIMITATIONS, PROVIDE WIRING DEVICES EQUIVALENT TO THOSE SPECIFIED FOR 20A, BUT RATED FOR 15A. PROVIDE THE FOLLOWING WIRING DEVICES WHERE SHOWN ON DRAWINGS OR REQUIRED. MINOR CHANGES RELATIVE TO THE LOCATION OF ELECTRICAL EQUIPMENT MAY BE MADE TO COMPLY WITH STRUCTURAL AND BUILDING REQUIREMENTS AS DETERMINED IN THE COURSE OF CONSTRUCTION. PROVIDE ALL WIRING DEVICES OF THE SAME MANUFACTURER AND NOT MIXED ON THE PROJECT, TO THE MAXIMUM EXTENT POSSIBLE. PROVIDE COLOR OF TOGGLES AND RECEPTACLES AS REQUESTED BY THE ENGINEER: Type of Device Hubbell Pass & Seymour Levlton Cooper Wiring Devices Duplex Receptacle CR5352 5352 5352 5352 GFCI Receptacle GF5352 2091 6898/6598 8300 -IG XGF20 IG5362 Isolated Ground (IG) Receptacle IG5362 IG6300 Single Pole Switch CS1221 PS 20 ACI 1221 -2 2221 16B 1 -11 SWITCH AND OUTLET COVER PLATES SWITCH AND OUTLET PLATES: COLORED, SMOOTH NYLON; BY THE SAME MANUFACTURER AS THE WIRING DEVICES, WHEREVER POSSIBLE. VERIFY DESIRED MATERIALS AND COLORS WITH ENGINEER BEFORE INSTALLATION. SWITCH PLATES IN UNFINISHED ROOMS AND SPACES: STAMPED STEEL, CADMIUM PLATED. INSTALL GROUPS OF SWITCHES UNDER ONE GANGED - PLATE, USUALLY HCRIZONTALLY; OR, WHERE REQUIRED BY DETAILS, VERTICALLY. SET ALL COVER PLATES PLUMB, PARALLEL, AND FINISHED FLUSH WITH THE WALL. 16B 1 -12 WEATHERPROOF COVER PLATES PROVIDE GFCI RECEPTACLES FOR DESIGNATED WEATHERPROOF RECEPTACLES, UNLESS INDICATED OTHERWISE ON THE DRAWINGS. FOR EXTERIOR UNATTENDED, WET LOCATIONS OR OTHER LOCATIONS AS INDICATED: IN -USE NEMA 3R RECESSED OR FLUSH MOUNT, UL- LABELED PLATES MOLDED FROM A CLEAR HIGH IMPACT ULTRAVIOLET STABILIZED POLYCARBONATE MATERIAL FOR EASY VERIFICATION THAT CORDS ARE PLUGGED IN AND THAT THE GFCI IS FUNCTIONING. BACK BOX MUST BE SUITABLE FOR CONDUIT CONNECTION. COORDINATE BACK BOX WITH WALL DEPTH. INTERMATIC WP1000RC /HRC OR EQUAL. COVER PLATES: BY THE SAME MANUFACTURER AS THE WIRING DEVICES; COMPLYING WITH NFPA 70 406.8 REQUIREMENTS FOR UNATTENDED USE. 16B 2 ELECTRICAL SERVICE AND GROUNDING 16B 2 -1 ELECTRICAL SERVICE SEE DRAWINGS FOR TYPE, SIZE, VOLTAGE, PHASE, AND OTHER REQUIREMENTS. PROVIDE, OR ARRANGE WITH THE SERVING UTILITY FOR INSTALLATION TO PROVIDE, A RECORDING VOLTMETER AT THE SERVICE POINT, ON THE FIRST DAY THE FACILITY IS OPEN FOR BUSINESS, FOR A 24 -HOUR VOLTAGE TEST. IF VOLTAGE AND REGULATION ARE NOT WITHIN ACCEPTABLE LIMITS, ARRANGE WITH THE UTILITY FOR PROPER VOLTAGE. SUBMIT TO THE OWNER A REPORT OF MAXIMUM AND MINIMUM VOLTAGE AND A COPY OF THE RECORDING VOLTMETER CHART. 16B 2 -2 GROUNDING PERMANENTLY AND EFFECTIVELY GROUND AND BOND THE ELECTRICAL INSTALLATION IN A THOROUGH AND EFFICIENT MANNER, AND IN CONFORMANCE, AT A MINIMUM, WITH NFPA 70, OR THESE DOCUMENTS, WHERE THEY EXCEED CODE REQUIREMENTS. USE BARE OR INSULATED CONDUCTORS, AS SPECIFIED HEREIN, AND OTHER MATERIALS INDICATED ON THE DRAWINGS. 16B 3 DISTRIBUTION AND CONTROL EQUIPMENT 16B 3 -1 LIGHTING AND APPLIANCE PANELBOARDS PANELBOARDS: SQUARE D TYPE NQOD OR NF, AS APPLICABLE, BASED ON VOLTAGE AND AMPERE RATINGS AND REQUIRED SHORT- CIRCUIT INTERRUPTING RATINGS AS SCHEDULED ON THE DRAWINGS, OR APPROVED EQUAL BY SIEMENS, CUTLER HAMMER, OR GENERAL ELECTRIC; COMPLETE WITH BOLT -ON THERMAL MAGNETIC, MOLDED CASE CIRCUIT BREAKERS ASSEMBLED IN A DEAD -FRONT FINISHED CABINET CONTAINING A TYPEWRITTEN CARD DIRECTORY INDICATING EXACTLY WHAT EACH CIRCUIT BREAKER CONTROLS; FULLY -RATED AND WITH THE INTEGRATED SHORT CIRCUIT CURRENT RATINGS INDICATED ON THE DRAWINGS. PLUG -IN TYPE BREAKERS WILL NOT BE ACCEPTABLE. ALL TWO AND THREE POLE BREAKERS: COMMON TRIP TYPE. BREAKERS USED AS SWITCHES FOR 120V OR 277V LIGHTING CIRCUITS: APPROVED FOR THE PURPOSE AND MARKED "SWD ". BREAKERS USED FOR THE PROTECTION OF HVAC AND REFRIGERATION EQUIPMENT: HACR TYPE. 16B 3 -2 DISCONNECT (SAFETY) SWITCHES DISCONNECT (SAFETY) SWITCHES: SQUARE D, SIEMENS, CUTLER HAMMER, OR GENERAL ELECTRIC FUSED OR NON -FUSED (AS INDICATED ON DRAWINGS OR REQUIRED) NEMA KS1, HEAVY DUTY, EXTERNALLY OPERATED, VISIBLE -BLADE SAFETY SWITCHES; NEMA ENCLOSURE TYPE INDICATED ON THE DRAWINGS OR SUITABLE FOR THE ENVIRONMENT IN WHICH INSTALLED. BASED ON FUSIBLE SWITCH AND FUSE SIZES INDICATED, INCLUDE CLASS R, J, OR L FUSE PROVISIONS AS APPLICABLE. WHERE INDICATED, PROVIDE FUSIBLE SWITCHES PERMANENTLY LABELED AS SUITABLE FOR USE AS SERVICE ENTRANCE EQUIPMENT, WITH INTEGRAL AND SEPARATE NEUTRAL AND GROUND ASSEMBLIES, SUITABLE FOR THE SIZES OF CONDUCTORS INDICATED. DO NOT DOUBLE -LUG ANY TERMINATIONS NOT SPECIFICALLY LISTED AS SUITABLE FOR MORE THAN ONE CONDUCTOR. PROVIDE SWITCHES WHERE NOT FURNISHED WITH THE STARTING EQUIPMENT, AT ALL OTHER POINTS REQUIRED BY NFPA 70, AND WHERE INDICATED ON THE DRAWINGS. 16B 3 -3 FUSES PROVIDE EACH CIRCUIT AND SET OF FUSE CLIPS THROUGHOUT THE WORK WITH BUSSMANN, FERRAZ SHAWMUT, OR LITTLEFUSE FUSES, SIZES AND TYPES AS REQUIRED OR INDICATED. ALL FUSES LARGER THAN 600A: UL CLASS L, SIMILAR TO TYPE KRP -C BUSSMANN LOW PEAK OR EQUAL. FUSES USED TO PROTECT MOTORS: UL CLASS RK5, BUSSMANN FUSETRON OR EQUAL. FUSES USED TO PROTECT ALL OTHER ELECTRICAL EQUIPMENT: UL CLASS RK1, DUAL ELEMENT, BUSSMANN LPS /LPN OR EQUAL. ALL FUSED DEVICES SHALL BE LABELED AS TO TYPE AND SIZE OF FUSE REQUIRED. FURNISH THREE SPARE FUSES OF EACH SIZE AND TYPE USED ON THE PROJECT (EXCEPT FOR MAIN SWITCH FUSES, FURNISH ONE SPARE), NEATLY CONTAINED IN A PROPERLY LABELED CABINET. 16B 4 LIGHT FIXTURES. LAMPS AND BALLASTS 16B 4 -1 LIGHT FIXTURE LOCATIONS LIGHT FIXTURES SHOWN ON THE ELECTRICAL DRAWINGS REPRESENT GENERAL ARRANGEMENTS ONLY. REFER TO ARCHITECTURAL DRAWINGS FOR MORE EXACT LOCATIONS. COORDINATE LOCATION WITH ALL OTHER TRADES BEFORE INSTALLATION TO AVOID CONFLICTS. COORDINATE LIGHT FIXTURE LOCATIONS IN MECHANICAL ROOMS WITH FINAL INSTALLED PIPING AND DUCTWORK LAYOUTS. 16B 4 -2 LIGHT FIXTURES PROVIDE LIGHT FIXTURES AS SCHEDULED ON DRAWINGS, INCLUDING ALL LAMPS, ALL NECESSARY ACCESSORIES, MATERIAL AND LABOR TO SECURELY HANG, CLEAN, AND MAKE LIGHT FIXTURES COMPLETELY READY FOR USE. LIGHT FIXTURE MODEL NUMBERS SCHEDULED ON THE DRAWINGS SHOW ONLY THE MANUFACTURER, GRADE AND STYLE OF LIGHT FIXTURES REQUIRED. PROVIDE: ALL HANGERS, SUPPORTS, AND MISCELLANEOUS HARDWARE REQUIRED TO INSTALL LIGHT FIXTURES; PROPER TRIM TO FIT EACH CEILING CONDITION ACTUALLY ENCOUNTERED; ADDITIONAL TIE WIRES CONNECTED TO STRUCTURE TO CONFORM TO SEISMIC REQUIREMENTS WHERE REQUIRED BY THE APPLICABLE BUILDING CODE. PACKAGING OF LIGHT FIXTURES WILL NOT BE ALLOWED. ONLY THOSE LUMINARIES LISTED IN THE LIGHT FIXTURE SCHEDULE, OR APPROVED IN ACCORDANCE WITH SUBSTITUTIONS OF THESE SPECIFICATIONS, WILL BE ACCEPTED. WHERE THE LIGHT FIXTURE SCHEDULE INDICATES AN ALLOWANCE FOR A SPECIFIC LIGHT FIXTURE, THE PRICE IS A CONTRACTOR PRICE. INCLUDE ALL ADDITIONAL COSTS FOR FREIGHT, LAMPS, AND INSTALLATION OF LIGHT FIXTURE AND LAMPS. SURFACE -MOUNT ALL FLUORESCENT LIGHT FIXTURES LOCATED IN AREAS WITHOUT SUSPENDED CEILINGS UNLESS OTHERWISE INDICATED ON THE DRAWINGS. PROVIDE RIGID METAL SPACERS FINISHED IN WHITE ENAMEL BETWEEN THE TOP OF EACH LIGHT FIXTURE AND THE CEILING ABOVE TO MAINTAIN A 1 -1/2 -INCH SPACE. SPACERS SHALL BE APPROVED BEFORE INSTALLATION. INSTALL FLUORESCENT LIGHT FIXTURES HUNG IN CONTINUOUS ROWS ON CHANNEL STRUTS SPECIFICALLY DESIGNED FOR THIS PURPOSE. INSTALL ALL FLUORESCENT LIGHT FIXTURES LOCATED IN AREAS WITHOUT CEILINGS IMMEDIATELY BELOW THE ROOF- FRAMING MEMBERS, OR SUSPENDED FROM CHAIN HANGERS SUITABLE IN LENGTH TO PROVIDE THE INDICATED MOUNTING HEIGHT. HANGERS: "HYDEE" HANGER TYPE FOR OUTLET BOX MOUNTING, COMPLETE WITH GROUNDING RECEPTACLE, PLUG, 3 -WIRE CORD AND NECESSARY CHAIN. THROUGH WIRING OF RECESSED LIGHT FIXTURES, IN SUSPENDED CEILINGS, IS NOT PERMITTED. CONNECT EACH LIGHT FIXTURE BY A WHIP TO A JUNCTION BOX. PROVIDE CABLE WHIPS OF SUFFICIENT LENGTHS TO ALLOW FOR RELOCATING EACH LIGHT FIXTURE WITHIN A 5 -FOOT RADIUS OF ITS INSTALLED LOCATION, BUT NOT EXCEEDING 6 FEET IN UNSUPPORTED LENGTHS. 16B 4 -3 EMERGENCY LIGHTING UNITS AND EXIT SIGNS DESCRIPTION: SELF - CONTAINED UNITS COMPLYING WITH UL 924. BATTERY: SEALED, MAINTENANCE -FREE, LEAD -ACID TYPE. THE BATTERIES SHALL BE OF SUITABLE RATING AND CAPACITY TO SUPPLY AND MAINTAIN AT NOT LESS THAN 87 1/ 2 PERCENT OF THE NOMINAL BATTERY VOLTAGE FOR THE TOTAL LAMP LOAD ASSOCIATED WITH THE UNIT FOR A PERIOD OF AT LEAST 1 1/ 2 HOURS, OR THE UNIT EQUIPMENT SHALL SUPPLY AND MAINTAIN NOT LESS THAN 60 PERCENT OF THE INITIAL EMERGENCY ILLUMINATION FOR A PERIOD OF AT LEAST 1 1/ 2 HOURS. 2. CHARGER: FULLY AUTOMATIC, SOLID -STATE TYPE WITH SEALED TRANSFER RELAY. 3. OPERATION: RELAY AUTOMATICALLY TURNS LAMP ON WHEN POWER SUPPLY CIRCUIT VOLTAGE DROPS TO 80 PERCENT OF NOMINAL VOLTAGE OR BELOW. AUTOMATICALLY DISCONNECTS FROM BATTERY WHEN VOLTAGE APPROACHES DEEP - DISCHARGE LEVEL. WHEN NORMAL VOLTAGE IS RESTORED, RELAY DISCONNECTS LAMPS FROM BATTERY, AND BATTERY IS AUTOMATICALLY RECHARGED AND FLOATED ON CHARGER. TEST PUSH BUTTON: PUSH -TO -TEST TYPE, IN UNIT HOUSING, SIMULATES LOSS OF NORMAL POWER AND DEMONSTRATES UNIT OPERABILITY. LED INDICATOR LIGHT: INDICATES NORMAL POWER ON. NORMAL GLOW INDICATES TRICKLE CHARGE; BRIGHT GLOW INDICATES CHARGING AT END OF DISCHARGE CYCLE. LAMP 4. lighted restrike by INTEGRAL SELF -TEST: FACTORY- INSTALLED ELECTRONIC DEVICE AUTOMATICALLY INITIATES CODE- REQUIRED TEST OF UNIT EMERGENCY OPERATION AT REQUIRED INTERVALS. TEST FAILURE IS ANNUNCIATED BY AN INTEGRAL AUDIBLE ALARM AND FLASHING RED LED. 16B 4 -4 LAMPS PROVIDE LAMPS AS INDICATED ON THE DRAWINGS FOR ALL LIGHT FIXTURES; OR, IF NOT INDICATED, AS RECOMMENDED BY THE LIGHT FIXTURE MANUFACTURER. IN ALL CASES, LAMPS SHALL BE COMPATIBLE WITH THE SPECIFIED LIGHT FIXTURE. ACCEPTABLE LAMP MANUFACTURERS: GENERAL ELECTRIC, OSRAM /SYLVANIA, PHILIPS, OR VENTURE. ALL FLUORESCENT LAMPS SHALL BE MINIMUM OF 3500 DEGREES K, WITH A MINIMUM COLOR- RENDERING INDEX OF 70, UNLESS NOTED OR DIRECTED OTHERWISE. ALL FLUORESCENT LAMPS IN SALES AREAS SHALL BE 3000 DEGREES K WITH A COLOR - RENDERING INDEX OF 80. ALL METAL HALIDE LAMPS IN SALES AREAS SHALL BE COATED, 3000 DEGREES K WITH A COLOR- RENDERING INDEX OF 70. INCANDESCENT LAMPS: TYPE AND WATTAGE AS SHOWN ON THE DRAWINGS; RATED 130V UNLESS OTHERWISE SCHEDULED OR SPECIFIED. 16B 4 -5 BALLASTS FLUORESCENT BALLASTS: LOW HEAT TYPE; THERMALLY PROTECTED AGAINST OVERHEATING; ETL -CBM, CLASS P TO MEET ALL REQUIREMENTS OF SECTION 410 -73 (E) OF THE NFPA 70 AS A MINIMUM; COMPLY WITH THE NATIONAL BALLAST ENERGY LAW; 90- PERCENT POWER FACTOR OR GREATER; SOUND LEVELS NOT EXCEEDING CLASS A AMBIENT NOISE LEVELS. BALLASTS IN INDOOR LOCATIONS SHALL HAVE DISCONNECTING MEANS EITHER INTERNAL OR EXTERNAL TO THE LUMINAIRE. 1. INDOOR FLUORESCENT BALLASTS: ELECTRONIC TYPE SUITABLE FOR OPERATION OF T8 LAMPS; TOTAL HARMONIC DISTORTION LESS THAN 20 PERCENT; FREQUENCY OF OPERATION OF 20 KHZ OR GREATER WITH NO VISIBLE FLICKER; LINE TRANSIENT WITHSTAND RATINGS AS DEFINED IN ANSI /IEEE C62.41, CATEGORY A; MANUFACTURERS: ADVANCE REL /VEL SERIES OR APPROVED EQUAL BY MAGNETEK, MOTOROLA, OR OSRAM. COMPACT FLUORESCENT BALLASTS: SHALL BE THERMALLY PROTECTED AGAINST OVERHEATING; SHALL BE CLASS P; SHALL HAVE A MINIMUM 90 PERCENT POWER FACTOR; SOUND LEVELS SHALL NOT EXCEED CLASS A AMBIENT NOISE LEVELS; AND SHALL BE LOW HEAT TYPE. ALL BALLASTS SHALL BE BY ADVANCE. BALLASTS FOR 36W THRU 55W LAMPS SHALL BE MARK V ELECTRONIC TYPE. HIGH - INTENSITY DISCHARGE (HID) BALLASTS (INCLUDES HIGH PRESSURE SODIUM (HPS) AND METAL HALIDE (MH)): SHALL HAVE A POWER FACTOR GREATER THAN 90 PERCENT; COMPLY WITH UNDERWRITERS LABORATORY (UL) 1029; PROVIDE NORMAL OPERATION AND LIGHT OUTPUT WITH THE INPUT VOLTAGE IS WITHIN 10 PERCENT OF NOMINAL BALLAST RATING (EXCEPT HPS LAMPS SMALLER THAN 250W WHICH MUST HAVE THE INPUT VOLTAGE WITHIN +5 PERCENT); SHALL HAVE A MINIMUM STARTING TEMPERATURE OF -20 DEGREES F. PROVIDE ENCAPSULATED AND REMOTE TYPES WHERE INDICATED ON THE DRAWINGS. EMERGENCY FLUORESCENT BALLASTS: SHALL BE BODINE B50 OR IOTA 1 -232 FOR FOUR -FOOT FLUORESCENT LAMPS; SHALL BE BODINE B30 OR IOTA 1 -160 FOR EIGHT - FOOT FLUORESCENT LAMPS. 16B 5 MISCELLANEOUS ELECTRICAL 16B 5 -1 WIRING OF MECHANICAL EQUIPMENT PROVIDE ALL RACEWAYS AND POWER WIRING FOR ALL DIVISION 15 EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS, INCLUDING, BUT NOT LIMITED TO, PUMPS, WATER HEATERS, AND HVAC EQUIPMENT, AND ALL LINE - VOLTAGE CONTROL AND INTERLOCK WIRING NOT PROVIDED UNDER DIVISION 15. CONNECT PER MANUFACTURERS' WIRING DIAGRAMS. COORDINATE WITH DIVISION 15 FOR DISCONNECTS FURNISHED WITH EQUIPMENT, AND PROVIDE ALL DISCONNECT SWITCHES AS REQUIRED. AFTER INSTALLING WIRING, VERIFY THAT EACH MOTOR LOAD HAS THE CORRECT PHASE ROTATION. VERIFY THE ACTUAL "MAXIMUM OVERCURRENT PROTECTION" (MOCP) DEVICE RATINGS AND "MINIMUM CIRCUIT AMPACITY" (MCA) CONDUCTOR SIZING FOR MECHANICAL EQUIPMENT FROM THE EQUIPMENT NAMEPLATE. BASE ELECTRICAL INSTALLATIONS ON ACTUAL REQUIRED AMPERAGES, WHICH MAY VARY SOMEWHAT FROM THE CONDUCTOR AND EQUIPMENT SIZES SHOWN ON THE DRAWINGS; HOWEVER, IN NO CASE, REDUCE THE SIZE OF CONDUCTORS INDICATED ON THE DRAWINGS WITHOUT AUTHORIZATION FROM THE ENGINEER. PROVIDE PROPERLY SIZED ELECTRICAL WIRING AND EQUIPMENT WITHOUT EXTRA COST TO THE OWNER. NOTIFY THE ENGINEER OF ALL CHANGES REQUIRED IN THE ELECTRICAL INSTALLATION DUE TO EQUIPMENT VARIANCES SO THAT THE EFFECTS ON FEEDERS, BRANCH CIRCUITS, PANELBOARDS, FUSES AND CIRCUIT BREAKERS CAN BE CHECKED PRIOR TO PURCHASING AND INSTALLATION. BE RESPONSIBLE FOR COORDINATING WITH DIVISION 15 TO VERIFY THE ACTUAL AMPACITIES AND CORRECT SIZES OF ALL CONDUCTORS AND OVERCURRENT PROTECTIVE DEVICES FOR ALL EQUIPMENT, AND CORRECT OVERLOAD HEATERS FOR ALL MOTORS, WHEN STARTERS ARE PROVIDED UNDER DIVISION 16. 16B 5 -2 WIRING OF THERMOSTATS, TIME AND TEMPERATURE CONTROLS PROVIDE ALL RACEWAYS, POWER WIRING, AND LINE - VOLTAGE CONTROL AND INTERLOCK WIRING NOT PROVIDED UNDER DIVISION 15, FOR ALL THERMOSTATS, TEMPERATURE CONTROL DEVICES, AND CONTROLS, INCLUDING, BUT NOT LIMITED TO, NIGHT - STATS, WATER HEATER INTERLOCKS, TIME SWITCHES AND OVERRIDE TIMERS. SEE MECHANICAL DRAWINGS FOR LOCATIONS AND TEMPERATURE CONTROL DIAGRAMS. LOW- VOLTAGE CONDUCTORS FOR THERMOSTATS AND TEMPERATURE CONTROL SYSTEM MAY BE RUN EXPOSED ABOVE FINISHED ACCESSIBLE CEILINGS, IF APPROVED AND LISTED FOR THIS PURPOSE, BUT SHALL BE INSTALLED IN CONDUIT WITHIN WALLS AND WHERE EXPOSED IN THE WORK AREAS. 16B 5 -3 TELEPHONE SYSTEM PROVISIONS PROVIDE INCOMING TELEPHONE SERVICE RACEWAYS AS INDICATED ON DRAWINGS OR AS REQUIRED BY THE SERVING TELEPHONE COMPANY. PROVIDE 3/4 -INCH THICK PLYWOOD BOARD, FIRE - RETARDANT - TREATED AND STAMPED FRT, SECURELY ANCHORED TO THE WALL, AT THE LOCATION AND OF THE SIZE AS INDICATED ON THE DRAWINGS. PROVIDE FLUSH MOUNTED TELEPHONE OUTLET BOXES WITH 1 -INCH EMT STUB -UP CONCEALED TO ACCESSIBLE CEILING SPACE AT LOCATIONS AS INDICATED ON THE DRAWINGS. 16B 5 -4 DATA SYSTEM PROVISIONS PROVIDE FLUSH MOUNTED DATA OUTLET BOXES WITH 1 -INCH CONDUIT STUB -UP CONCEALED TO ACCESSIBLE CEILING SPACE AT LOCATIONS AS INDICATED ON THE DRAWINGS. 16B 5 -5 TIME SWITCHES TIME SWITCHES: TYPE INDICATED, WITH MANUAL BYPASS SWITCH, NEMA ENCLOSURE SUITABLE FOR THE ENVIRONMENT INSTALLED; NUMBER AND TYPES OF CONTACTS, SEQUENCE, AND VOLTAGE AS INDICATED ON THE DRAWINGS, OR AS REQUIRED, BASED ON THE TIME SWITCH FUNCTION AND THE NUMBER OF BRANCH CIRCUITS OR CONTACTORS CONTROLLED. PROVIDE WIRING TO PHOTOCELLS, CONTACTORS, RELAYS OR OTHER CONTROL POINTS AS REQUIRED. MANUFACTURERS: INTERMATIC, PARAGON OR TORK. TYPE: 1. ELECTRONIC DIGITAL. TIME SWITCH MUST ALSO COMPLAY WITH SECTION 1513.6.2 OF THE WASHINGTON STATE ENERGEY CODE AS SHOWN ON SHEET E303. 16B 5 -9 MISCELLANEOUS EQUIPMENT AND CONNECTIONS ALL WIRING AND CONNECTIONS TO ILLUMINATED CASES. ALL WIRING AND CONNECTIONS OF EXIT DOOR ALARMS. END OF SECTION 16B IG� ptotTU�yM111.A ovi LLoe-- 5 to (e) f r_ 1HENDERSON ENGINEERS=_ 8325 LENEXA DRIVE LENEXA, KS 66214 TEL 913 742 5000 FAX 913 742 5001 www.hei- eng.com 0750002188 RSP Architects 502 S. College Avenue Suite 203 Tempe, AZ 85281 Certification 480.889.2000 480.889.2099 fax www.rsparch.com RSP Architects, Ltd. with Terry Washington No. 6634 Location Westfield Southcenter 201 Southcenter Mall Tukwila, WA 98188 Project For Project No. Drawn By 1688.005.02 KH -J Checked By C L D ate 05.06.08 NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of ASP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. ® Copyright ASP Architects 2003. All rights reserved. ELECTRICAL SPECIFICATIONS E302 O: \Solstice10750002188 Solstice - South Center - Tukwila - WA \000 \EIec\0750002188E303.dwg, Plot, 518/2008 12:16:40 PM, kellyhyde, 1:1.00251 2006 Washington State Nonresidential Energy Code Compliance Form Instructions for Electronic Forms Revised July 2007 Start-up This file, LTG06.XLS, has electronic versions of the 2006 compliance forms for the lighting system, motors and transformers. Open a working copy of this file and be sure to use Save As to save it to a new file name. Alternatively, you can save the file as a template in the XLSTART subdirectory in the EXCEL directory, and open new copies with the "File New menu command. Look for "LTG06 ". There are three companion templates to this file: ENV06 -1.XLS (climate zone 1 envelope requirements); ENV06- 2.XLS (clirnate zone 2 envelope requirements); MECH06.XLS (Chapter 14 mechanical systems requirements). Overview This workbook file contains multiple worksheets. Each worksheet is indicated by a tab at the bottom of the screen. (If you don't see the tabs, visit menu option "Tools- Options- View -Sheet Tabs ".) You may visit each form by clicking an its tab. Most calculations are automated. The spaces which display the results of calculations are not editable. Some adjustments to formatting have been made to facilitate electronic filling and calculation of the forms. Save Files Each time you open this file and start filling forms, you must save it under a new filename of your choosing using File Save As. The original template file cannot be altered. You may also save your own versions of the forms this way. Getting Around Each form has two pages (front and back). Both pages are available on screen when you click the tab for a form. Use the scroll bars to find the second page. 0 is either to the right, below, or sometimes to the right and below the first page. Filling Fields All project info and the date for all forms is entered once on "PRJ -SUM" and automatically reproduced on the other forms. Always fill in the heading of PRJ -SUM, even if you will not be using that form. The other forms have a reminder to do this. Only fellable fields are accessible. If you try to edit any other field, you'll get an error message. You may use the TAB key to move to the next (liable field. If the TAB doesn't take you where you want to go, use the mouse. Avoid excessively long text strings when entering information. In some cases, text that extends beyond the available space will sirnply not be seen. In most cases, the text will wrap within the cell. This may force part of the form onto a new page To enter the date, use this format: rnm /ddlyyyy. For example, you -would enter 7/1 /2006 or 12/15/2007. Check boxes can be either blank, or checked -off with an "x" shown in the box. To toggle between cases, click the box with your mouse. Radio buttons (circles) are either filled or unfilled. Only one in a set may be filled. Drop -down lists have an arrow at the right side of the space. Click the arrow with your mouse and select the appropriate option. One of the options is a blank. When a form has a space for notes or explanation, click anywhere in the space to edit. Your cursor will become a text editing insertion bar and you can edit as with a word processor. Personal- iZing You can personalize the forms with your company name, address, phone, or any other information. This is done by editing the footer using File Page Setup Header /Footer. You can then save the.file under a new template name and re -use it again. Adding Lines and Removing Many tables, such as for listing equipment types, have a certain number of lines for entering data. There may not always be enough lines for all the entries you need to make. With this electronic version, you can add additional lines to the table. To add additional Iines•where this feature is available, click on the " +" button with your mouse. • This button is located to the right of the sheet. 0 you can't see it. scroll right (or change the View Zoom setting to 83 %). To remove lines that you have added, click on the " -" button with your mouse. You cannot remove lines that were not added; an error appears if you try. 0 you add additional lines with this method, the pagination will usually be affected. The forms will be forced to carry additional lines over to other pages.. Be sure to submit all pages to the plans examiner. Printing The forms should print on any printer supported by Windows. You will need to have the fallowing TrueType fonts installed under Windows: Arial, Times New Roman, Courrier New and Wingdings. These are all standard Windows fonts. If you are losing form or flowchart details when printing, you may have a shortage of printer memory. Try printing problem pages individually. • By default, only selected forms are printed. To select one or more forms, hold down the Ctrl key and click the tabs of the worksheets you need. Issue the File Print Selected Sheets command. To print the entire set, use File Print Entire Workbook. Clean Forms It is possible to print clean, blank versions of these farms for hand filling. To do so, delete all of the heading information at the beginning of PRJ -SUM, and make sure that all finable cells in the forms are empty. Then print the clean forms. For each radio button group, there is a button labeled "Clear'. Clicking this button will clear the other buttons so that they will print as empty circles. The "Clear" button will not print. Partial Form Sets Forms in a workbook may not be deleted, because the file is locked, B3but you need not print all the forms, as explained in "Printing" above. 2006 Washington State Nonresidential Energy Code Compliance Form Exterior Lighting Summary LTG -EXT 2005 Washington State Nonresidential Energy Code Compliance Forms Re ed July 2007 Project Info Proj Addres -201 South center Mall Date 5/2/2008 Tukwila, WA 89188 For Building Department Use Main Entry Name : Kelly Hyde Appl. Name 7330 N. 16th St. Suite 5110 Phoenix, AZ 85020 Appl. Phone 602- 336 -5231 Project Description Q New ❑ Addition ❑ Alteration ❑ Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Coinpliance Option C) Lighting Pourer Allowance Q Systems Analysis Building Grounds (luminaires > 100 Watts) ❑ Efficacy > 60 lumens/VV ❑ Controlled by motion Sensor ❑ Exemption (list) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Tradable Maximum Allowed Lighting Wattage Tradable Locations Description Allowed Watts per ft' or per 0 Area (312), perimeter (If) or # of items Allowed Walls x ft' (or x If) Main Entry Front Door 30 WILF of door widt 18.0 540.0 50W Halogen Accent Light 2 Building Entrances and Exits 50.0 100.0 Other doors 20 W /linear foot of door width Canopies and Overhangs Canopies (free standing and attached and overhangs) 1.25 W /ft2 Tradable Proposed Lighting Wattage Total Allowed Watts 540.0 Use mfgr listed maximum input wattage. For fixtures with hard -wi ed ballasts only, the default table in the NREC Technical Reference Manual may also be used Location Description Fixture Description Number of Fixtures Watts/ Fixture Walkways less than 10 feet wide Watts Proposed main Entry -Front Door Type 8 50W Halogen Accent Light 2 Building Entrances and Exits 50.0 100.0 Other doors 20 W /linear foot of door width Canopies and Overhangs Canopies (free standing and attached and overhangs) 1.25 W /ft2 Outdoor Sales Open areas (including vehicle sales lots) 0.5 W /ft Street frontage for vehicle sales lots in addition t0 "open area" allowance 20 Wllin ar lout Non- Tradable Surfaces (Lighting power density calculations for the following applications can be used only for the specific application and cannot be spaded between slufac d or with other exterior lighting. The following allowances are in addition to any allowance otherwise permitted in the "Tradable Surfaces" section of this table.) Building Facades 0.2 Wife for each illuminated wall or surface or 5.0W /linear foot for each illuminated wall or surface length Automated teller machines and night depositories Total Proposed Watts may not exceed Total Allowed Watts for Exterior Non- Tradable Maximum Allowed Lighting Wattage Total Proposed Watts 100.0 Non - Tradable Locations Description Allowed Watts per ft' or per If Area (52), perimeter (If) or # of items Allowed Watts x ft' (or x If) Walkways less than 10 feet wide 1.0 W /linear foot Walkways 10 feet wide or greater Plaza areas Special feature areas 0.2W/11- Stairways 1.0 W/ft Building Entrances and Exits Main entries 30 W /linear foot of door width Other doors 20 W /linear foot of door width Canopies and Overhangs Canopies (free standing and attached and overhangs) 1.25 W /ft2 Outdoor Sales Non- Tradable Proposed Lighting Wattage Location Fixture Description Number of Fixtures Watts/ . Fixture Watts Proposed Walkways less than 10 feet wide 1.0 W /linear foot Walkways 10 feet wide or greater Plaza areas Special feature areas 0.2W/11- Stairways 1.0 W/ft Building Entrances and Exits Main entries 30 W /linear foot of door width Other doors 20 W /linear foot of door width Canopies and Overhangs Canopies (free standing and attached and overhangs) 1.25 W /ft2 Outdoor Sales Proposed Watts may not exceed Allowed Watts for Category 2006 Washington State Nonresidential Energy Code Compliance Form Instructions for Electronic Forms Revised July 2007 Re -Calcu latiori As this is a large file, it may respond slowly to changes if it is set to automatically re- calculate after every action. To set calculation to manual, visit the " Tools - Options - Calculation" menu item. Then manually recalculate using the F9 key. 2006 Washington State Nonresidential Energy Code Compliance Form Exterior Lighting Summary (back) LTG -EXT 2006 Washington Mato Nonrosidenlial Energy Code Compliance Forms TABLE 15 -2 LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS • 000505 July 2007 Tradable Surfaces (Lighting power densities for uncovered parking areas, building grounds, building enhances and exits, canopies and overhangs and outdoor sales areas may be traded.) Uncovered Parking Areas Parking Tots and drives 0.15 W /110 Building Grounds Walkways less than 10 feet wide 1.0 W /linear foot Walkways 10 feet wide or greater Plaza areas Special feature areas 0.2W/11- Stairways 1.0 W/ft Building Entrances and Exits Main entries 30 W /linear foot of door width Other doors 20 W /linear foot of door width Canopies and Overhangs Canopies (free standing and attached and overhangs) 1.25 W /ft2 Outdoor Sales Open areas (including vehicle sales lots) 0.5 W /ft Street frontage for vehicle sales lots in addition t0 "open area" allowance 20 Wllin ar lout Non- Tradable Surfaces (Lighting power density calculations for the following applications can be used only for the specific application and cannot be spaded between slufac d or with other exterior lighting. The following allowances are in addition to any allowance otherwise permitted in the "Tradable Surfaces" section of this table.) Building Facades 0.2 Wife for each illuminated wall or surface or 5.0W /linear foot for each illuminated wall or surface length Automated teller machines and night depositories 270 W per location piths 90 W per additional ATM per location Entrances and gatehouse inspection stations at guarded facilities z 1.25 W/ft of uncovered area (covered areas are included in the "Canopies and Overhangs" section of "Tradable Surfaces ") Loading areas for law enforcement, fire, ambulance and other emergency service vehicles 0.5 W /112 of uncovered area (covered areas are included in the "Canopies and Overhangs" section of "Tradable Surfaces ") Material handling and associated storage 0.5 W /ft2 Drive -up windows at fast food restaurants 400W per drive - through Parking near 24 -hour retail entrances 800 W per matt entry 2006 Washington Stale Nonresidential Energy Code Compliance Form Project Summary PRJ -SUM 2000 Washington State Nonres.derttiel Energy Code Compliance Fcnrs Revised July 2007 Project Info Project Address 201 South Center Mall Ceiling Height for this room Ceiling Height limit for this exception "" Date 5/2/2008 Sales Tukwila, WA 89180 :3.00 10.0 feet 12 feet For Building Department Use Stockroom Retail Stockroom 1.50 10.0 feet 12 feet Applicant Name: xelly Hyde Restroom 0.00 10.0 feet Applicant Address: 7330 N. 16th St. Suite A110 Phoenix, AZ 05020 Applicant Phone: 802- 336 -5231 33..0 Health care clinic n. a. 2006 Washington State Nonresidential Energy Code Compliance Form Lighting Power Allowance Adjustments LTG -LPA 2000 Washington Mate Nurresidenlal Energy Code Compliance Forms Revised July 2007 Project Address 201 South Center 0211 Date 5/4/2008 Use this Coen if you are claiming any ceiling height adjustments for your Lighting Power Allowances for irterior lighting. The Occupancy Description should agree with the "Use" listed on Code Table 15.1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft'. Carry the Adjusted LPA to the corresponding "Allowed Watts per ft2" location on LTG -SUM. Ad Listed Lighting Power Allowances (Interior Location (floor /room no.) Occupancy Description Allowed Waits per ft, ss Ceiling Height for this room Ceiling Height limit for this exception "" Adjusted LPA Watts per 112 Sales Retail :3.00 10.0 feet 12 feet 3.00 Stockroom Retail Stockroom 1.50 10.0 feet 12 feet 1.50 Restroom Restroom 0.00 10.0 feet 12 feet 0.80 204.0 Restroom Existing Fluorescent Strip 1 31.0 33..0 Health care clinic n. a. Theater, performing arts vertical glazing Indicate vertical glazing on plans 1.2 Transportation n. a. 1 -2 Occupancies overhead glazing Indicate overhead glazing on plans Hotel/motel yes 1513.4 Display /exhib /special Indicate separate controls 0102 Workshops 1.4 1513.5 Exterior shut -off Schedule with type and features, indicate location yes "laboratory" shall meet office and other appropriate categories) (a) timer w /backup Indicate location - E102 Laundries no (1) photocell. Indicate location 1.3 Plans Submitted for Common Areas Only' 1513.6 Inter. auto shut -off Indicate location no 1513.6.1 (a) occup. sensors Schedule with type and locations 0.8 no . 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans no 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes 1514 Max. watts Indicate watts for each exit sign 0102 LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture 0303 yes 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture 0303 MOTORS (Section 1511) yes 1511 Elec motor efficiency MECliMOT or Equipment Schedule with hp, rpm, efficiency 0201 TRANSFORMERS (Section 1540) 21.0. I 1540 'Transformers Ilndicate size and efficiency I " From Table 15 -1 based on exceptions listed in footnotes 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary LTG -INT 2006 Wash:rooton Stale Nonresidential Energy Cede Compliance Forms Revised July 2007 Project Info Project Address- 201 South Center Mall Date 5/4/2008 Tukwila, WA 89168 For Building Department Use Sales Applicant Name: Kelly Hyde Applicant Address: 7330 N. 16027 St. Suite A110 Phoenix, AT 85020 Applicant Phone. 602- 336 -5231 Project Description ❑' New Building ❑ Addition ❑ Alteration ❑ Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Prescriptive 0 Lighting Power Allowance Q Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 6011 of the fixtures new, installed wattage not increased, & space use riot changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft? " Area in ft2 Allowed x Area Sales Retail 3.00 595.0 1785.0 Stockroom Retail storage 1.50 136.0 204.0 Restroom Common area (Restroom) 0.80 50.0 40.0 " From Table 15 -1 (over) - document all exceptions on form LTG -LPA Proposed Lighting Wattage Total Allowed Watts 2029.0 Location (floor/room no.) Fixture Description Number of - Fixtures Watts/ Fixture - Watts Proposed Sales Type C 20W. Metal Halide T4.5 Downlight 19 23.0 419.0 Location on Plans Type 0 70W Metal Halide Par30 Flood Adjustable Downlic 16 79.0 1264.0 Local control /access Type H 5018 Halogen Accent Light 2 50.0 100.0 Stockroom Type F2 4' 15 280 Strip Fluorescent 3 68.0 204.0 Restroom Existing Fluorescent Strip 1 31.0 33..0 Health care clinic n. a. Theater, performing arts vertical glazing Indicate vertical glazing on plans 1.2 Transportation n. a. 1 -2 Occupancies overhead glazing Indicate overhead glazing on plans Hotel/motel yes 1513.4 Display /exhib /special Indicate separate controls 0102 Workshops 1.4 1513.5 Exterior shut -off Schedule with type and features, indicate location yes "laboratory" shall meet office and other appropriate categories) (a) timer w /backup Indicate location - E102 Laundries no Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 2013.0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type Of included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. 2006 Washington State Nonresidential Energy Code Compliance Form Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK Forms Revised July 2007 2008 V.'ustanglon Mato No::res'dertal Energy Code Compliance Project Address 201 South Center Mall Date 5/2/2008 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required . Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control /access Schedule with type, indicate locations E102 Dormitory yes 1513.2 Area controls Maximum limit per switch E201 School buildings (Group E Occupancy only), school classrooms, day care centers n.a. 1513,3 Daylight zone control Schedule with type and features, indicate locations 1.2 Health care clinic n. a. Theater, performing arts vertical glazing Indicate vertical glazing on plans 1.2 Transportation n. a. 1 -2 Occupancies overhead glazing Indicate overhead glazing on plans Hotel/motel yes 1513.4 Display /exhib /special Indicate separate controls 0102 Workshops 1.4 1513.5 Exterior shut -off Schedule with type and features, indicate location yes "laboratory" shall meet office and other appropriate categories) (a) timer w /backup Indicate location - E102 Laundries no (1) photocell. Indicate location 1.3 Plans Submitted for Common Areas Only' 1513.6 Inter. auto shut -off Indicate location no 1513.6.1 (a) occup. sensors Schedule with type and locations 0.8 no . 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans no 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes 1514 Max. watts Indicate watts for each exit sign 0102 LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture 0303 yes 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture 0303 MOTORS (Section 1511) yes 1511 Elec motor efficiency MECliMOT or Equipment Schedule with hp, rpm, efficiency 0201 TRANSFORMERS (Section 1540) 21.0. I 1540 'Transformers Ilndicate size and efficiency I If "no" is circled for any question, provide explanation: 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary (back) LTG -INT 2006 Washington Mate Noruasidenliel Energl'Code Compliance Forms Hoarsest July 2007 Spaces Prescriptive S P P Occupancy: 0 Warehouses, storage areas or aircraft storage hangers (Other Qualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) - ❑Check if 95% or ore of fixtures comply with 1,2 or 3 and rest are ballasted. m 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5 -60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired oleo- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps 0= 150w c) electronic ballasts 3. LED lights. TABLE 15 -1 Unit Lighting Power Allowance (LPA Use LPA2(W /sf) Use Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools] hospitals, institutions, museums, banks, churches) " LPA`(WJsf) 1.0 Automotive facility 0.9 Convention center 1.2 Penitentiary and other Gr 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations 1.0 Cafeterias, fast food establishments , restaurants /barss 1.3 Post office 1.1 Dormitory 1.0 Retail10, retail banking, mall concourses, wholesale stores !pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia", assembly sp- 1.0 .Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1.2 Transportation 1A 1 -2 Occupancies Hotel/motel 1.0 Warehouses ', stogie areas 0.5 Hotel banquet/conference /exhibition hall' 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified , 1.8 Parking garages 0.2 "laboratory" shall meet office and other appropriate categories) ' Laundries 1.2 Libraries° 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum - 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room nosy be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference ,001110 and offices less than 15000 with full height partitions, a Unit Lighting Power Allowance, of 1.10 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Pourer Allowance for the court area is 2.60 W /ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 wift' of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling - mounted back or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). e) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. 2006 Washington State Nonresidential Energy Code Compliance Form Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK 2006 Wahargton Stale Nonresidential Energy Code Compliance Forms - Revised July 2007 Lighting - General Requirements 1513 Lighting Controls: Lighting, including exempt lighting in Section 1512, shall comply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513.6.1. Where automatic lime switches are cited, they shall have the features listed in Section 1513.6.2. 1513.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling - height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of turning off all lights within the space. The controls shall be readily accessible, at the point of entry/exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized In remote locations: 1. Lighting controls for spaces which must be used as a whole. 2. Aulurrrano controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. • 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a 20 ampere circuit loaded to not more than 80 %. A master control may be Installed provided the individual switches retain their capability to function independently. Circuit breakers may not be used as the sole means of Switching. EXCEPTIONS: 1. Industrial or manufacturing process areas, as may be required for production. 2. Areas less than 5 %of the building footprint for footprints over 100,000 tt 6 . 1513.3 Daylight Zone Control: All daylighted zones, as . defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shall be provided with Individual controls, or daylight- or occupant - sensing automatic controls, which control the lights independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (I.e. north, east, south, west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent TIOto Nv: rtD cal ayligh glat zi spaces enclosed by soots or 0011100 height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting. 1513.4 Display, Exhibition and Specialty Lighting Controls: All display, exhibition or specialty lighting shall be 'controlled independently of general area lighting. 1613.6 Automatic Strut -off Controls, Exterior: Lighting for all exterior applications shall have automatic controls capable of turning off exterior lighting when sufficient daylight is available or when the lighting is not required during nighttime hours. Lighting not designated for dusk -to -dawn operation shall be controlled by either: a. A combination of a photosensor and a time switch; or b. An astronomical time switch. Lighting designated for dusk -to -dawn operation shall be controlled by an astronomical time switch or photosensor. All time switches shall be capable of retaining programming and the time setting during loss of power for a period of at least 10 hours. EXCEPTION: Lighting for covered vehicle entrances or exits from buildings or parking structures where required for safely, security, or eye adaptation. 1513.6 Automatic Shut -Off Controls, Interior: Buildings greater than 5,000 ft' and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied) ours. Within these buildings, all office areas less than 300 ft2 enclosed by walls or ceiling - height partitions, and all meeting and conference rooms, and all school classrooms, shall be equipped with occupancy sensors that comply with Section 1513.6.1. For outer spaces, automatic controls may be an occupancy sensor, time switch or other device capable of automatically shutting off lighting. • EXCEPTIONS: 1. Areas that must be continuously illuminated (e.g., 24 -hour convenience stores), or illuminated In a manner requiring manual operation of the lighting. 2. Emergency lighting systems. 3. Switching for industrial or manufacturing process facilities as may be required for production. 4. Hospitals and laboratory spaces. 5. Areas in which medical or dental tasks are performed are exempt from the occupancy sensor requirement. 1513.6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically turning off all the lights in an area, no more than 30 minutes after the area has been vacated. Light fixtures controlled by occupancy sensors shall have a wall - mounted, manual switch Capable of turning off lights when the space is occupied. EXCEPTION: Occupancy sensors in stairwells are allowed to have two step lighting (high -light and low - light) provided the control fails In the high -light position. 1513.6.2 Automatic Time Switches: Automatic tune h a mmu day of being switches set s for all 7 have drftererlt ini day m types 7 per clock week and nbe ad capable incorporate an automatic holiday "shut -off' feature, which turns off all loads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. Automatic time switches shall incorporate an over -ride switching device which: a. is readily accessible; b. Is located so that a person using the device can sae the lights or the areas controlled by the switch, or so that the area being illuminated is annunciated; c. is manually operated; 0. allows the lighting to remain on for no more than 2 hours when an over -ride is initiated; and • e. controls an area not exceeding 5,000 fl' or 5% of the building footprint for footprints over 100,000 ft2, whichever is greater. 1513.7 Commissioning Requirements: For lighting controls which include daylight or occupant sensing automatic controls, automatic shut -off controls, occupancy sensors, or automatic time switches, the lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans arid specifications. A complete report of test procedures and results shall be prepared and fled with the owner. Drawing notes shall require commissioning in accordance with this paragraph. 1514 Exit Signs: Exit signs shall have an input power demand of 5 Watts or less per sign. Motors - General Requirements 1511 Electric Motors: All permanently wired polyphase motors of 1 hp or more, which are not part of an HVAC system, shall comply with Section 1437. EXCEPTIONS: 1. Motors that are an integral part of specialized process equipment. 2. Where the motor is integral to a listed piece of equipment for which no complying motor has been approved. Transformers - General Requirements SECTION 1540 - TRANSFORMERS The minimum efficiency of a low voltage dry-type distribution transformer shall be the Class 1 Efficiency Levels for distribution transformers specified in Table 4 -2 of the "Guide for Determining Energy Efficiency for Distribution Transformers" published by the National Electrical Manufacturers Association (NEMA TP -1- 2002). MEWED FOR CODE COMPLIANCE E NEPA 7 MAY 16 2008 City Of Tukwila ILDIts DIVISION . ELOB s4 V,00ra) 134 art °r 1HENDERSON ENGINEERS= 8325 LENEXA DRIVE LENEXA, KS 66214 TEL 913 742 5000 FAX 913 742 5001 www.hei- eng.com 0750002188 RSP Architects 502 S. College Avenue Suite 203 Tempe, AZ 85281 Certification 480.889.2000 480.889.2099 fax www.rsparch.com RSP Architects, Ltd. with Terry Wobken Washington No. 6634 Location Westfield Southcenter 201 Southcenter Mall Tukwila, WA 98188 Project For Project No. Drawn By 1688.005.02 KH Checked By CL Date 05.06.08 NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of ASP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright ASP Architects 2003. All rights reserved. ELECTRICAL ENERGY CALCULATIONS E303