Loading...
HomeMy WebLinkAboutPermit D10-041 - OTIS ELEVATOR COMPANY - PARTITIONSOTIS ELEVATOR COMPANY 13035 GATEWAY DR SUITE 157 D10 -041 Citygf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 0004800015 Address: 13035 GATEWAY DR TUKW Suite No: DEVELOPMENT PERMIT Permit Number: D10 -041 Issue Date: 03/04/2010 Permit Expires On: 08/31/2010 Tenant: Name: OTIS ELEVATOR COMPANY Address: 13035 GATEWAY DR, STE 157 , TUKWILA WA Owner: Name: RREEF AMERICA REIT II CORP/ Address: PO BOX 4900 #207 , SCOTTSDALE AZ 85261 Phone: Contact Person: Name: JESSE C ZEIGLER Address: PO BOX 995 , CARNATION WA 98014 Phone: 425 681 -1070 Contractor: Name: R C ZEIGLER CO INC Address: PO BOX 995 , CARNATION WA 98014 Phone: 425- 333 -4797 Contractor License No: RCZEICI183MN Expiration Date: 07/25/2011 DESCRIPTION OF WORK: RELOCATION OF (2) INTERIOR NON -LOAD BEARING PARTITIONS TO ENLARGE EXISTING OFFICE SPACE. Value of Construction: $5,000.00 Fees Collected: $306.95 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2006 Type of Construction: VB Occupancy per IBC: 0008 * *continued on next page ** doc: IBC -10/06 D10-041 Printed: 03 -04 -2010 City okukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http://www.citukwila.wa.us Permit Number: D10 -041 Issue Date: 03/04/2010 Permit Expires On: 08/31/2010 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: -J1( Date: ` t O I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction o = •�; • r thorized to sign and obtain this development permit. Signature: ' —� Date: 3 1 a S e55e C This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Print Name: doc: IBC -10/06 D10 -041 Printed: 03 -04 -2010 Parcel No.: 0004800015 Address: Suite No: Tenant: • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 13035 GATEWAY DR TUKW OTIS ELEVATOR COMPANY PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D10-041 ISSUED 02/12/2010 03/04/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. 10: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: ** *FIRE DEPARTMENT CONDITIONS * ** 15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the doc: Cond -10/06 D10 -041 Printed: 03 -04 -2010 following concerns: • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75 or less. (IFC 906.3) (NFPA 10, 3 -2.1) 17: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 18: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 19: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 20: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 21: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 22: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 23: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 24: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 25: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 26: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 nun) high with the principal strokes of the letters not less than 0.75 inch (19.1 min) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) doc: Cond -10/06 D10-041 Printed: 03 -04 -2010 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 27: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 28: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 29: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) The path of egress shall require emergency lighting until exit discharge is accomplished. 30: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 31: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 32: All new sprinlder systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinlder systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 33: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2051. 34: Local U.L. central station supervision is required. (City Ordinance #2051) 35: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 36: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 37: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 38: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 39: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 40: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 41: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 42: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 D10 -041 Printed: 03 -04 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: r' Date: Li , 1 0 Print Name: esse C- ordinances governing or local laws regulating doc: Cond -10!06 D10 -041 Printed: 03 -04 -2010 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hup://lvww.ci.urinvila.Iva.us Building Permit No. V 0 -1) Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: 13035 gateway Drive Tenant Name: Otis Elevator Company King Co Assessor's Tax No.: 000480001502 Suite Number: New Tenant: Property Owners Name: CB Richard Ellis - Gregory D. Coleman 157 Floor: 1 ❑ Yes ®..No 98168 Zip Mailing Address: 12720 Gateway Drive Suite 200 Tukwila Wa City State CONTACT PERSON - who do your permit is ready to be issue Name: R.C. Zeigler Company, Inc. / Jesse C. Zeigler Day Telephone: (425) 681 -1070 Mailing Address: POB 995 Carnation WA 98014 E -Mail Address: zeigler777 @gmail.com City State Fax Number: (425) 549 -0163 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: R.C. Zeigler Company, Inc. Mailing Address: POB 995 Carnation, Wa. 98014 Contact Person: Jesse C. Zeigler E -Mail Address: zeigler777 @gmail.com Contractor Registration Number: RCZEIC1183MN City State Day Telephone: (425) 681 -1070 (425) 549 -0163 Expiration Date: 05/31/2010 Fax Number: Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: none Mailing Address: City Day Telephone: Fax Number: Contact Person: E -Mail Address: State Zip ENGINEER OF RECORD All plans must be wet stamped by Engin r of Record Company Name: none Mailing Address: city Day Telephone: Fax Number: Contact Person: E -Mail Address: H:\ Applications\Forms- Applications On Line\2009 Applications \I -2009 - Permit Application.doc Revised: 1-2009 bh State Zip Page 1 of 6 BUILDING PERMIT INFORMATION - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ '9eTeees 5, coo Existing Building Valuation: $ 0 Scope of Work (please provide detailed information): ' ' ' - Ca9a€4.2aipt tG Relocation of Two (2) interior partitions to enlarge existing office space. Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square, Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes m No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms- Applications On Line\2009 Applications \1-2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1$` Floor 5,155 5,155 0 0 V 13 2°d Floor 3,172 3,172 0 0 3'" Floor 0 0 Floors thru ' Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes m No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms- Applications On Line\2009 Applications \1-2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Signat NT: Date: 02/11/2010 Print Name: .C. eig - ompany, Inc. / Jesse C. Zeigler Day Telephone: (425) 681 -1070 Carnation Mailing Address: POB 995 WA 98014 City State Zip Date Application Accepted: II' l t) Date Application Expires: 011 l �� I Staff Initials: ,/� /1 H:\Applications \Forms- Applications On Line\2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bh Page 6 of 6 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 0004800015 Address: 13035 GATEWAY DR TUKW Suite No: Applicant: OTIS ELEVATOR COMPANY RECEIPT Permit Number: D10-041 Status: APPROVED Applied Date: 02/12/2010 Issue Date: Receipt No.: R10 -00378 Payment Amount: $187.80 Initials: WER Payment Date: 03/04/2010 09:52 AM User ID: 1655 Balance: $0.00 Payee: JESSE ZEIGLER TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA - Authorization No. 095155 ACCOUNT ITEM LIST: Description 187.80 Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 183.30 640.237.114 4.50 Total: $187.80 PYM E NT RECEIJED doc: Receiot -06 Printed: 03 -04 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 0004800015 Address: 13035 GATEWAY DR TUKW Suite No: Applicant: OTIS ELEVATOR COMPANY RECEIPT Permit Number: D10-041 Status: PENDING Applied Date: 02/12/2010 Issue Date: Receipt No.: R10 -00250 Payment Amount: $119.15 Initials: JEM Payment Date: User ID: 1165 Balance: 02/12/2010 11:47 AM $187.80 Payee: JESSE C ZEIGLER TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA - Authorization No. 114704 ACCOUNT ITEM LIST: Description 119.15 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 119.15 Total: $119.15 PAYMENT RECEIVED doc: Receiot -06 Printed: 02 -12 -2010 11S INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 M Project: . v T S e(P ' AZ0 r of Inspection: I'.•nd( ZU I.1 . Address: /3 0 3.5 G s4 Date Call Date Special Instructions: /Deed 60)6_ eff . L e/ rr l to / -7 Date Wanted: a.m. 1 -/4 -I0 Requester: Phone 2sr laY/ " 670 r Approved per applicable codes. Corrections required prior to approval. COMMENTS: (?).04 5-0 0 A.- 10( e)1. ti 24 Inspey>;6r: ' etti k , Date . 1/ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection,"fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: �A. _Mac is maTIWIf9!. .se.•Jelk ._ .2... _u_ ��wSeet• —. _ ..nl..•_ -- INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. 1'� (206)431 -3670 Project: Type of spection: e_..ti /i .....7 Address: (303.5 6 �A----7a& Date Called: Special Instructions: Q3 q 3113 —6( Date Wanted: - 2fi -(�m� P•m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: ctor: j $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Insp Date: 2 _ i 4) Receipt No.: Date: . ate . a..o aver _ *Ina aturlud t� 3 INSPECTION NO. INSPECTION RECORD Retain a copy with permit to -o4/ PERMIT NO. CITY OF TUKWILA BUILDING DIVISION le' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Project: p vkT'1 Type of I spection* _ c ` . fi DC's '' `` o'r- 5 Ciie Address: 1 3035 G �� Date.0 led , ,dc._ = WLI Special Instructions: 03q1 ` 54..E / –�� Date Wanted -I 4 I Q rp Requester: Phone No: bea -5(4– 1116 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: e,� Inspectq : J� Date: ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 2,— INSPECTION NO. INSPECTION RECORD Retain a copy with permit Qlc) -coq! CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (20`6)431 -36j7 Proj ct: 07"...5 � � ( ��'( -P Type of Inspection: Ff A A( coK `To c--au -Q-r or /1/4 e, Address: / 3 o35 G of'"-F..4.4).1-7 ,o4,. Date Called: _ Special Instructions: �3 qi 15 f - di SWPhone ste Date Wanted: 3 '-/Cr-it) ;1 t .m. Requester: ; A J AA aro 6 p e.AI, 3 i) I ._.J 1 e 11 . •) J f f No: / 4 t -s '- / /'7 1 J I Approved per applicable codes. orrections required prior to approval. COMMENTS: coK `To c--au -Q-r or /1/4 e, (-, J e,,,-1- .n-e R 3L, 1 1 ...),-/A4 ( ) 1.1,PJp �v;t Ar`,,; r ?1 ^'c:. 1`,A -: ste .7.57 ^�.k:r 1 A S1� e. tom+ ;1 ,, ,s, e P A. P k--1{ pr. ; A J AA aro 6 p e.AI, 3 i) I ._.J 1 e 11 . •) J f f t' (I' 1, J I . 1 t Inspector: /' Date:3 1g_�J ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: L- INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431 -3670 Project: dT,'S fie t i t Go, Typ of Inspection: 4ie r ,re cdArr - I Address: 136.3S G wai DR Date Called: Special Instructions: 3$ �� (Ale � —GI 4t 4 Date Wanted: ,1 .....q — /v a ri p m Requester: No: Phone S / 1 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Ins(pector: 1' Date G 1 0 El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 0 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit iO O!- PERMIT NUMBERS • CITY OF TUKWILA FIRE DEPARTMENT. 444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 - - Project: .� Sprinklers: -Fire Alarm_ : Type of Inspection: op� S t _ ro u tz! fr' Address:. � 3 35_ Suite #: Goo, i__. ft iZ 1_S 7 Contact Person: Special Instructions: Phone No:: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: -- Sprinklers: -Fire Alarm_ : Hood & Duct: Monitor: .Pre -Fire: Ptermits: - _ Occupancy- Type: — — I Inspector: If'1,, s-9--_ • Date: 3, i /Je . Hrs.: • / n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a. reinspection. Word /Inspection. Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 • R.C. ZEIGLER COMPANY, INC. City of Tukwila Dept. of Community Development 6300 SouthCenter BLVD. Suite #100 Tukwila, Wa. 98188 Attn: Allen Johannessen RE: Permit App. # D10 -041 Building Tradition Since 1982 February 26, 2010 Please find below clarifications regarding the "General Notes" within the Determination of Completeness Memo. 1. Please find attached plans drawn to scale — 1/8" = 1' 2. Area of alterations is highlighted. All other work is existing. The project consists of minor alterations to (2) offices. 3. All new walls shall consist of 31/2" steel studs, acoustical insulation within walls and 5/8" type x sheetrock smooth finished each side. The building is a wood framed structure. All new walls will be securely fastened at the floor and ceiling with wood screws into the structure. 4. Minor lighting and mechanical revisions may occur and will be handled under the appropriate permit. Please feel free to contact the office at 425 - 333 -4797 with any further questions or clarifications. Respectfully, P.O. BOX 995 Carnation, WA 98014 P. 425.333.4797 1 F. 425.549.0163 1 C. 425.681.1070 Construction • Management • Consultation • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director February 18, 2010 Jesse C Zeigler PO Box 995 Carnation, WA 98014 RE: Incomplete Letter #1 Development Permit Application D10 -041 Otis Elevator —13035 Gateway Dr Dear Mr. Zeigler, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on February 12, 2010 is determined to be incomplete. Before your application can continue the plan review process the attached /following items from the following department(s) need(s) to be addressed: Building Department: Allen Johannessen at 206 433 -7163 if you have any questions concerning the attached comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, AILQ et/le\■Q/r Bill Rambo Permit Technician Enclosures File: D10 -041 W: \Permit Center \Incomplete Letters\2010\D10 -041 Incomplete Ltr 4 1.DOC 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • Tukwila Building Division Allen Johannessen, Plan Examiner Determination of Completeness Memo Date: February 18, 2010 Project Name: Otis Elevator Company Permit #: D10 -041 Plan Review: Allen Johannessen, Plans Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) L Provide plans drawn to scale. Reduced plan sheets shall not be sufficient for review. 2. Highlight the area of work. Identify that which is existing and which is new construction. 3. Provide building type of construction information. Include details to identify all elements and materials used in the new construction and show method of securing new construction to existing building floor and ceiling. 4. Identify any alterations that may apply to ceiling systems or other building elements to include lighting, ventilation etc. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. • AERMIT000 COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D10 -041 DATE: 02/26/10 PROJECT NAME: OTIS ELEVATOR SITE ADDRESS: 13035 GATEWAY DR Original Plan Submittal Response to Correction Letter # X Response to Incomplete Letter # 1 Revision # after Permit Issued DEPARTMENT )-1O 4uitding 440on • Public Works ❑ r/1 ire Prevention Structural Planning Division ❑ Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Kt - Comments: Incomplete ❑ DUE DATE: 03/02/10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Building Please Route Structural Review Required _ No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03/30/10 Approved n Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents routing slip.doc 2 -28 -02 f PERMITCOORDCOPYr PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D10 -041 DATE: 02/11/10 PROJECT NAME: OTIS ELEVATOR COMPANY SITE ADDRESS: 13035 GATEWAY DR, STE 157 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPART ENTS• tlTlding i ion 0 Pub lic Wo ks \revention A-,JC, :2-I d Structural alt Plantning DivlJ4 l� nPermit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ❑ Comments: Incomplete xf DUE DATE: 02/16/10 Not Applicable Permit Center Use Only 1 _ 0 INCOMPLETE LETTER MAILED: o" 0 LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Building Please Route ❑ REVIEWER'S INITIALS: Structural Review Required ❑ No further Review Required n DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions ❑ Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DUE DATE: 03/16/10 DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 • City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 9 -d`10. IC) Plan Check/Permit Number: D 10 -041 ® Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Otis Elevator Project Address: 13035 Gateway Dr CITY OF 7'1 JUI FEB 2 6 2010 PERMIT CENTER Contact Person: Ze eX Phone Number: _ 4?-S- Summary of Revision: \ease d cam\ �. C\a r-` ct 'w ' k- cecr. r\ es ArecAS c O e cIv`ic \e 0, -. fp U OL\\ 0 n S 00-‘D "''v(xe—% U : ,`if?`_ Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on 07, \applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Contractors or Tradespeople Peter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name R C Zeigler Co Inc UBI No. 600442150 Phone 4253334797 Status Active Address Pob 995 License No. RCZEICI183MN Suite /Apt. License Type Construction Contractor City Carnation Effective Date 7/15/1982 State Wa Expiration Date 7/25/2011 Zip 98014 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status ZEIGLCC223QB Zeigler Construction Company Construction Contractor General Unused 11/2/1978 7/15/1989 Archived Business Owner Information Name Role Effective Date Expiration Date Zeigler, Richard C President 07/15/1982 Bond Amount Zeigler, Muriel A Vice President 07/15/1982 KC3552 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 TRAVELERS CAS & STY CO OF AMER KC3552 07/15/2006 Until Cancelled $12,000.0004/10 /2006 3 ST PAUL FIRE & MARINE INS CO KC3552 07/15/2002 07/15/2006 $12,000.0007/25 /2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 22 NAVIGATORS SPEC INS SE06CGL00366303 07/15/2007 07/15/2010 $1,000,000.0007 /09/2009 21 NIC INS CO SE06CL003663 00 07/15/2006 07/15/2007 $1,000,000.00 07/13/2006 20 NAVIGATORS INS CO GNW500004 07/15/2005 07/15/2006 $1,000,000.00 07/07/2005 19 OOHIO CAS INS BK0552976522 07/15/2004 07/15/2005 $1,000,000.0007 /15/2004 18 0010 CAS INS BK052976522 07/15/2003 07/15/2004 $1,000,000.0007 /12/2004 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 03/04/2010 -xis' EXIST. WOOD JOiSTS, 00140 E TOPPING PLYWOROet AND Mez cte lir fr.ir SEPARATE PERMIT REQUIRED FOR: jethanioal OlrElectrIcal lumbIng Cirbas Piping City of Tukwila BUILDING DIVISION ON ROLES EXIST, FLOOR TO GEEING CABIN 41. WI SPED/ES FELE C410PY I) • r Penult No Plan review approval is subject t • OfMIS and ongssIons. Approval of construction docum ,nts does not authorize the violation of any adopted cod: or ordinance. Receipt ol approv • - = t ons Is acknowledged: roip Office Resource IMMIN IMMO 11111111111111 1111111111M IMMO 1011/11M IIIIIMM.• nimai MN= MINIM MIME EXIST. 6" IN001 STD, 14!)1/1 %V/ R.19 INSLILA ION EXISTV WOOD I STDAALLS MST. SEED f PANTED WALLS (EXPOSED DEVI SEMI HEATED R No changes shall made to the scope of work witho prior approval of Tukwila Bui ding Division. Will re uirp, a new plan submittal EXIST, Lavv WALT° V.4" C CARPLT Ek*EXIST V=NEIN VCr EP— tot EPDXY PAINT f. PRIOR TO PERFORMING ANY DEMOLMOIV ACTIVITIES ALL CONTRACTORS SHALL VERIFY ALL INTERIOR FIELD CONDITIONS AT THE SITE AND NOTIFY MANAGEMENT OF ANY DISCREPANCIES ON THE DRAWINGS. a COORDINATE ALL DEMOLITION ACTIVITY WITH BUILDING OWNER/MANAGEMENT 9, PROTECT ALL EXISTING WINDOWS AND DOORS DURING DEMOLITION, REPLACE AS REQUIRED IF DAMAGED. 1, COORDINATE ALL DEMOLITION WITH CONSTRUCTION, POWER/TELEPHONE/DATA, AND FURNITURE/EQUIPMENT PLANS, 5.. DEMOLISH EXISTING WALLS, DOORS, DOORFRAMES, COAT RODS, MILLWORK AND ELECTRIC DEVICES IN AREAS DESIGNATED ON DEMOLITION PLAN, 5. PATCH AND R ,EF'AIR ALL CEILING, WALL, COLUMN ENCLOSURES, AND FLOORS AS REQUIRED, MAKE READY FOR NEW FINISHE„S TO MATCH EXISTING ADJACENT FIAIISHES. ?, CONTRACTOR TO PROVIDE FOR CONTINUOUS OPERATION OF ALL, BUILDING SECURITY, FIRE ALARM AND FIRE SUPPRESSION SYSTEMS DURING THE COURSE OF DEMOLITION WORK, 9. ALL EXISTING SURFACES TO REMAIN ARE TO BE PROTECTED THROUGHOUT CONSTRUCTION., 9, RELOCATE GE/LING ITEMS INCLUDING LIGHTING, HVAC DIFFUSERS AND RETURN GRILLS TO PROVIDE A COMPLETE AND COORDINATED PLAN. .01, REMOVE AND DISCARD ALL EXISTING CARPETING THROUGHOUT THE ENTIRE OFFICE AREA.. REMOVE ANY GLUE RESIDUE FROM SUBSTRATE, .FLASH PATCH SUBSTRATE IN AREAS RECEIVING NEW FLOOR FINISH TO CREATE A SMOOTH LEVEL SURFACE FREE OF ANY DEBRIS .AND DEFECTS FOR NEW FINISHES, (1) IN EXISTING BUILT OUT OFFICE AREA REMOVE WALL SECTIONS. REPAIR PERPENDICULAR WALL SURFACES TO !WATCH ADJACENT CONSTRUCTION AND PREPARE FOR NEW FINISHES. SEE GENERAL DEMOLITION NOTE 5. C) REMOVE SAFETY RAILING AT EXISTING MEZZANINE EDGE. 6) IN EXISTING TOILET ROOM, REMOVE EXISTING MILLWORK, AND PLUMBING ":" FIXTURES, PATCH AND REPAIR WALLS, AND FLOOR FOR A PROFESSIONAL FINISH, FOUR !ARM SPRINGS FAluilsoTON, Cv 00082 PRIOR TO PERFORMING ANY CONSTRUCTION ACTIVITIES ALL CONTRACTORS SHALL VERIFY ALL FIELD CONDITIONS AT THE SITE AND NOTIFY TENANT OF ANY DISCREPANCIES ON THE DRAWINGS, 2, REUSE EXISTING DOOR IF POSSIBLE, NEW DOORS SHALL MATCH BUILDING STANDARD AND BE FINISHED TO MATCH EXISTING SURROUNDING CONDITIONS. a PROVIDE AND INSTALL ALLAPPLICABLE HARDWARE TO THOSE DOORS INDICATED AS' HAVING LOOK...PROVIDE SEPARATE KEYING FOR THE OFFICE ANO MEZZANINE/WAREHOUSE. SPACES ON A COMMON MASTER KEY SYSTEM. PROVIDE (2) SETS OF KEYS TO EACH LOCK TO TENANT. TIOCK INDICATES PRIVACY SET 4* REPLACE EXISTING SHEET VINYL FLOORING IN MEN'S AND WOMEN'S ROOM WITH NEW VCT PROVIDE AND INSTALL CARPETING FOR ALL OTHER OFFICE AREA SPACES. TENANT TO SELECT COLORS FOR VCT AND CARPET, 5. MODIFY, REPLACE OR SUPPLEMENT EXISTING HVAC SYSTEM AS REQUIRED • TO ACCOMMODATE NEW SPACE USAGE* PROVIDE ALL NECESSARY DESIGN,ENGINEE13ING SERVICES REWIRED TO EVALUATE EXISTING HVAC SYSTEM IN ORDER TO DELIVER A COMPLETE SOLUTION IN SUPPORT OF THE NEW LAYOUT, ALL WORK SHALL MEET OUTLINE PERFORMANCE SPECIFICATIONS AND ALL APPLICABLE CODES. 6. PROVIDE AND INSTALL ALL NECESSARY WOOD BLOCKING, NAILERS AND FURRING REQUIRED FOR MOUNTING TOILET ACCESSORIES, AND SYSTEMS FURNITURE WHERE REQUIRED, PAINTALL IST FL. EXIST, TOILET RMS, (S. NEW CONSTRUCTION AS SPECIFIED.. 8. CLEAN/REPLACE ANY AGED OR DAMAGED CEILING TILES OR GRID. 9* RELOCATE AND ADD Lia.H7 FIXTURES,. DIFFUSERS, SPRINKLEFI HEADS, ETC., FOR COCOPLETE AND COORDINATED INSTALLATION, 10, EXISTING LIGHT FIXTURES THROUGHOUT INTERIOR BUILDING AND LOADING DOCK AREA TO SE IN GOOD WORKING CONDITION, ADD/REPAIR/REPLACE/RELOCATE OR ADJUST AS NEEDED TO ACCOMMODATE NEW LAYOUT AND MEET ALL APPLICABLE CODE REQUIREMENTS AS WELL AS SPECIFIC.ATIONS. I I. ALL ELECTRICAL, MECHANICAL, PLUMBING, SPRINKLER SYSTEMS TO BE CODE COMPLIANT AND IN GOOD WORKING ORDER. KEYED CONSTRUCTION NOTES: Open Officv Office TAM ARE4 AREA CALCULATIONS: USEABLE TOTAL SF 9,111 WAREHOUSE SF 1,508 OFFICE 1ST FL SF 3,647 OFFICE 2ND FL •SF 2,259 MEZZANINE SF 913 TRAINING $F 730 CAPACITY 37 OFFICE SF/CAP, 160 IMEN4S ROOM AND WOMEN`S ROOM TO BE ADA CONIPLIANT PROVIDE AND INSTALL ADA COMPLIANT FIXTURES, GRAB BARS AND ALL STANDARD ACCESSORIES, FEB 2 6 2010 PERMIT CENTER Suite 157113035 Gateway Dr. Tukwila, WA 981684396 Move Add Change Package 1AT PRIVATE OFFICE 207, RETURN INTERIOR OFFICE PARTITION TO NEAREST EXTERIOFI WIAIDOW MULLION. 1NEW SEPARATION WALLS BETWEEN OFFICE SPACES AND MEZZANINE/WAREHOUSE SPACES SHALL BE EXTENDED TO THE UNDERSIDE OF THE DECK ABOVE WITH SOUND ATTENUATION INSULATION FROM TOP TO BOTTOM, AND CONSTRUCTED TO MEET CODE REQUIREMENTS, REVIEWED FOR CODE COMPLIANCE APPROVED MAR 0 2 2910 ArS City ot Tukwila BUILDING DIVISION PROVIDE AND INSTALL 34-0W X 4P-0"H WINDOW SILL TO BE AT 3*-0" AFF. RELOCATE EXISTING GE/LING SLOT FOR EXISTING RECESSED PROJECTOR SCREEN, MODIF'Y CEILING GRID AND TILES ACCORDINGLY, AREA, Jr113 tir Demolition/Construction J PROVIDE AND INSTALL NEW WALL CONSTRUCTION AT FORMER DOOR OPENING, PROVIDE METAL STUD CONSTRUCTION, INSULATE COMPLETELY AND PROVIDE GYPSUM BOARD BOTH SIDES. 1PROVIDE AND INSTALL 12'Wx12"H VISION PANEL WAREHOUSE 105 DOOR TO OPEN OFFICE 102 PRAWN fAe An etitEtt. CI-IMMO BY: bag: PM 1 2/1) 8)2009