HomeMy WebLinkAboutPermit D10-041 - OTIS ELEVATOR COMPANY - PARTITIONSOTIS ELEVATOR
COMPANY
13035 GATEWAY DR
SUITE 157
D10 -041
Citygf Tukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.ci.tukwila.wa.us
Parcel No.: 0004800015
Address: 13035 GATEWAY DR TUKW
Suite No:
DEVELOPMENT PERMIT
Permit Number: D10 -041
Issue Date: 03/04/2010
Permit Expires On: 08/31/2010
Tenant:
Name: OTIS ELEVATOR COMPANY
Address: 13035 GATEWAY DR, STE 157 , TUKWILA WA
Owner:
Name: RREEF AMERICA REIT II CORP/
Address: PO BOX 4900 #207 , SCOTTSDALE AZ 85261
Phone:
Contact Person:
Name: JESSE C ZEIGLER
Address: PO BOX 995 , CARNATION WA 98014
Phone: 425 681 -1070
Contractor:
Name: R C ZEIGLER CO INC
Address: PO BOX 995 , CARNATION WA 98014
Phone: 425- 333 -4797
Contractor License No: RCZEICI183MN
Expiration Date: 07/25/2011
DESCRIPTION OF WORK:
RELOCATION OF (2) INTERIOR NON -LOAD BEARING PARTITIONS TO ENLARGE EXISTING OFFICE SPACE.
Value of Construction: $5,000.00 Fees Collected: $306.95
Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2006
Type of Construction: VB Occupancy per IBC: 0008
* *continued on next page **
doc: IBC -10/06
D10-041 Printed: 03 -04 -2010
City okukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http://www.citukwila.wa.us
Permit Number: D10 -041
Issue Date: 03/04/2010
Permit Expires On: 08/31/2010
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone:
Hauling: N Start Time: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use: Profit: N Non - Profit: N
Water Main Extension: Private: Public:
Water Meter: N
Permit Center Authorized Signature:
-J1(
Date: ` t O
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction o = •�; • r thorized to sign and obtain this development permit.
Signature: ' —� Date: 3 1 a
S e55e C
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
Print Name:
doc: IBC -10/06
D10 -041 Printed: 03 -04 -2010
Parcel No.: 0004800015
Address:
Suite No:
Tenant:
•
City of Tukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
13035 GATEWAY DR TUKW
OTIS ELEVATOR COMPANY
PERMIT CONDITIONS
Permit Number:
Status:
Applied Date:
Issue Date:
D10-041
ISSUED
02/12/2010
03/04/2010
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design
requirements of ASCE 7.
6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced
to the building structure.
7: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
9: Manufacturers installation instructions shall be available on the job site at the time of inspection.
10: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the
International Building Code and the Washington State Ventilation and Indoor Air Quality Code.
11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila
Permit Center.
12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
14: ** *FIRE DEPARTMENT CONDITIONS * **
15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
doc: Cond -10/06
D10 -041 Printed: 03 -04 -2010
following concerns:
•
City of Tukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
16: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is
calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A,
20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75 or less. (IFC 906.3) (NFPA 10, 3 -2.1)
17: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or
brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation
instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so
that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross
weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the
floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4
inches (102 mm). (IFC 906.7 and IFC 906.9)
18: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot
be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6)
19: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available
for use. These locations shall be along normal paths of travel, unless the fire code official determines that the
hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5)
20: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that
indicates the month and year that the inspection was performed and shall identify the company or person performing the
service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge
procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the
inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these
required surveys. (NFPA 10, 4 -3, 4 -4)
21: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort.
(IFC 1008.1.8.3 subsection 2.2)
22: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle
is engaged from inside the tenant space. (IFC Chapter 10)
23: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the
International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC
1008.1.8.1)
24: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10)
25: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress
travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress
travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access
corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the
nearest visible exit sign. (IFC 1011.1)
26: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 nun) high with
the principal strokes of the letters not less than 0.75 inch (19.1 min) wide. The word "EXIT" shall have letters having
a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be
less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire
Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high
contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not
energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction
cannot be readily changed. (IFC 1011.5.1)
doc: Cond -10/06
D10-041 Printed: 03 -04 -2010
•
City of Tukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
27: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90
minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system
provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3)
28: Aisles leading to required exits shall be provided from all portions of the building and the required width of the
aisles shall be unobstructed. (IFC 1013.4)
29: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means
of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the
floor level. The power supply for the means of egress illumination shall normally be provided by the premise's
electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less
than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2,
1006.3) The path of egress shall require emergency lighting until exit discharge is accomplished.
30: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating
and/or adding sprinkler heads. (IFC 901.4)
31: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate
flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3)
32: All new sprinlder systems and all modifications to existing sprinkler systems shall have fire department review and
approval of drawings prior to installation or modification. New sprinlder systems and all modifications to sprinkler
systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk
Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to
the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050)
33: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and
City Ordinance #2051.
34: Local U.L. central station supervision is required. (City Ordinance #2051)
35: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require
relocation and/or addition of audible /visual notification devices. (City Ordinance #2051)
36: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire
Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC
104.2)
37: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this
project.
38: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70)
39: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth
in Table No. 803.5 of the International Building Code.
40: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and
#2051)
41: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
42: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
doc: Cond -10/06
D10 -041 Printed: 03 -04 -2010
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work
construction or the performance of work.
Signature: r' Date: Li , 1 0
Print Name:
esse C-
ordinances governing
or local laws regulating
doc: Cond -10!06 D10 -041
Printed: 03 -04 -2010
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
hup://lvww.ci.urinvila.Iva.us
Building Permit No. V 0 -1)
Mechanical Permit No.
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
Site Address: 13035 gateway Drive
Tenant Name:
Otis Elevator Company
King Co Assessor's Tax No.: 000480001502
Suite Number:
New Tenant:
Property Owners Name:
CB Richard Ellis - Gregory D. Coleman
157
Floor: 1
❑ Yes ®..No
98168
Zip
Mailing Address: 12720 Gateway Drive Suite 200
Tukwila
Wa
City
State
CONTACT PERSON - who do
your permit is ready to be issue
Name: R.C. Zeigler Company, Inc. / Jesse C. Zeigler
Day Telephone: (425) 681 -1070
Mailing Address: POB 995 Carnation WA 98014
E -Mail Address: zeigler777 @gmail.com
City State
Fax Number: (425) 549 -0163
Zip
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name: R.C. Zeigler Company, Inc.
Mailing Address: POB 995 Carnation, Wa. 98014
Contact Person: Jesse C. Zeigler
E -Mail Address: zeigler777 @gmail.com
Contractor Registration Number: RCZEIC1183MN
City State
Day Telephone: (425) 681 -1070
(425) 549 -0163
Expiration Date: 05/31/2010
Fax Number:
Zip
ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record
Company Name: none
Mailing Address:
City
Day Telephone:
Fax Number:
Contact Person:
E -Mail Address:
State
Zip
ENGINEER OF RECORD All plans must be wet stamped by Engin
r of Record
Company Name: none
Mailing Address:
city
Day Telephone:
Fax Number:
Contact Person:
E -Mail Address:
H:\ Applications\Forms- Applications On Line\2009 Applications \I -2009 - Permit Application.doc
Revised: 1-2009
bh
State
Zip
Page 1 of 6
BUILDING PERMIT INFORMATION - 206 - 431 -3670
Valuation of Project (contractor's bid price): $ '9eTeees 5, coo
Existing Building Valuation: $ 0
Scope of Work (please provide detailed information): ' ' '
- Ca9a€4.2aipt tG Relocation of Two (2) interior partitions to enlarge existing office space.
Will there be new rack storage? ❑ Yes
0.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square, Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling:
Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes ❑ No If "yes ", explain:
FIRE PROTECTION /HAZARDOUS MATERIALS:
❑ Sprinklers Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes m No
If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:Wpplications\Forms- Applications On Line\2009 Applications \1-2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
1$` Floor
5,155
5,155
0
0
V 13
2°d Floor
3,172
3,172
0
0
3'" Floor
0
0
Floors thru '
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling:
Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes ❑ No If "yes ", explain:
FIRE PROTECTION /HAZARDOUS MATERIALS:
❑ Sprinklers Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes m No
If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:Wpplications\Forms- Applications On Line\2009 Applications \1-2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 2 of 6
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING
Signat
NT:
Date: 02/11/2010
Print Name: .C. eig - ompany, Inc. / Jesse C. Zeigler Day Telephone: (425) 681 -1070
Carnation
Mailing Address: POB 995
WA 98014
City
State
Zip
Date Application Accepted:
II' l t)
Date Application Expires: 011
l ��
I
Staff Initials: ,/�
/1
H:\Applications \Forms- Applications On Line\2009 Applications \I -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 6 of 6
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Parcel No.: 0004800015
Address: 13035 GATEWAY DR TUKW
Suite No:
Applicant: OTIS ELEVATOR COMPANY
RECEIPT
Permit Number: D10-041
Status: APPROVED
Applied Date: 02/12/2010
Issue Date:
Receipt No.: R10 -00378
Payment Amount: $187.80
Initials: WER Payment Date: 03/04/2010 09:52 AM
User ID: 1655 Balance: $0.00
Payee: JESSE ZEIGLER
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA -
Authorization No. 095155
ACCOUNT ITEM LIST:
Description
187.80
Account Code Current Pmts
BUILDING - NONRES
STATE BUILDING SURCHARGE
000.322.100 183.30
640.237.114 4.50
Total: $187.80
PYM E NT
RECEIJED
doc: Receiot -06 Printed: 03 -04 -2010
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tukwila.wa.us
Parcel No.: 0004800015
Address: 13035 GATEWAY DR TUKW
Suite No:
Applicant: OTIS ELEVATOR COMPANY
RECEIPT
Permit Number: D10-041
Status: PENDING
Applied Date: 02/12/2010
Issue Date:
Receipt No.: R10 -00250
Payment Amount: $119.15
Initials: JEM Payment Date:
User ID: 1165 Balance:
02/12/2010 11:47 AM
$187.80
Payee: JESSE C ZEIGLER
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA -
Authorization No. 114704
ACCOUNT ITEM LIST:
Description
119.15
Account Code Current Pmts
PLAN CHECK - NONRES
000.345.830 119.15
Total: $119.15
PAYMENT
RECEIVED
doc: Receiot -06
Printed: 02 -12 -2010
11S
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION 1-
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
M
Project: .
v T S e(P ' AZ0 r
of Inspection:
I'.•nd( ZU I.1 .
Address:
/3 0 3.5 G
s4
Date Call
Date
Special Instructions:
/Deed 60)6_ eff . L
e/ rr l to
/
-7
Date Wanted: a.m.
1 -/4 -I0
Requester:
Phone 2sr laY/ " 670
r
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
(?).04 5-0 0 A.- 10( e)1.
ti
24
Inspey>;6r: ' etti k ,
Date . 1/
$60.00 REINSPECTION FEE REQUIRED. Prior to inspection,"fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
�A. _Mac is maTIWIf9!. .se.•Jelk ._ .2... _u_ ��wSeet• —. _ ..nl..•_ --
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
PERMIT NO.
1'�
(206)431 -3670
Project:
Type of spection: e_..ti /i .....7
Address:
(303.5 6 �A----7a&
Date Called:
Special Instructions:
Q3 q 3113 —6(
Date Wanted:
- 2fi -(�m�
P•m.
Requester:
Phone No:
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
ctor: j
$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Insp
Date: 2 _ i 4)
Receipt No.:
Date:
. ate . a..o aver _ *Ina aturlud
t� 3
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
to -o4/
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION le'
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3
Project:
p
vkT'1
Type of I spection* _ c ` . fi
DC's '' ``
o'r- 5 Ciie
Address:
1 3035 G
��
Date.0 led , ,dc._ = WLI
Special Instructions:
03q1 `
54..E
/
–��
Date Wanted -I 4 I Q
rp
Requester:
Phone No:
bea -5(4– 1116
Approved per applicable codes. El Corrections required prior to approval.
COMMENTS:
e,�
Inspectq : J�
Date:
❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
2,—
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
Qlc) -coq!
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
PERMIT NO.
(20`6)431 -36j7
Proj ct:
07"...5 � � ( ��'( -P
Type of Inspection:
Ff A A(
coK `To c--au -Q-r
or /1/4 e,
Address:
/ 3 o35 G of'"-F..4.4).1-7
,o4,.
Date Called:
_
Special Instructions:
�3 qi 15 f - di
SWPhone
ste
Date Wanted:
3 '-/Cr-it)
;1
t
.m.
Requester:
; A J AA aro 6 p
e.AI,
3 i) I ._.J 1 e 11 . •) J f f
No:
/ 4 t -s '- / /'7
1
J
I
Approved per applicable codes.
orrections required prior to approval.
COMMENTS:
coK `To c--au -Q-r
or /1/4 e,
(-, J e,,,-1- .n-e R 3L, 1
1 ...),-/A4
( ) 1.1,PJp �v;t Ar`,,;
r ?1 ^'c:. 1`,A -:
ste
.7.57 ^�.k:r 1 A S1� e. tom+
;1
,, ,s, e P A. P k--1{ pr.
; A J AA aro 6 p
e.AI,
3 i) I ._.J 1 e 11 . •) J f f
t' (I' 1,
J
I
. 1 t
Inspector: /'
Date:3 1g_�J
❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
L-
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
(206)431 -3670
Project:
dT,'S fie t i t
Go,
Typ of Inspection:
4ie r
,re cdArr - I
Address:
136.3S G
wai DR
Date Called:
Special Instructions:
3$
�� (Ale �
—GI 4t
4
Date Wanted: ,1
.....q — /v
a ri
p m
Requester:
No:
Phone S / 1
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
Ins(pector:
1'
Date G 1 0
El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
0
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
iO
O!-
PERMIT NUMBERS
• CITY OF TUKWILA FIRE DEPARTMENT.
444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 - -
Project:
.�
Sprinklers:
-Fire Alarm_ :
Type of Inspection: op�
S t _ ro u tz! fr'
Address:. � 3 35_
Suite #:
Goo, i__.
ft
iZ
1_S 7
Contact Person:
Special Instructions:
Phone No::
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
Needs Shift Inspection: --
Sprinklers:
-Fire Alarm_ :
Hood & Duct:
Monitor:
.Pre -Fire:
Ptermits: - _
Occupancy- Type: — —
I Inspector: If'1,, s-9--_
•
Date: 3, i /Je .
Hrs.: • /
n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a. reinspection.
Word /Inspection. Record Form.Doc 1/13/06
T.F.D. Form F.P. 113
•
R.C. ZEIGLER COMPANY, INC.
City of Tukwila
Dept. of Community Development
6300 SouthCenter BLVD. Suite #100
Tukwila, Wa. 98188
Attn: Allen Johannessen
RE: Permit App. # D10 -041
Building Tradition Since 1982
February 26, 2010
Please find below clarifications regarding the "General Notes" within the Determination of
Completeness Memo.
1. Please find attached plans drawn to scale — 1/8" = 1'
2. Area of alterations is highlighted. All other work is existing. The project consists of minor
alterations to (2) offices.
3. All new walls shall consist of 31/2" steel studs, acoustical insulation within walls and 5/8"
type x sheetrock smooth finished each side. The building is a wood framed structure. All
new walls will be securely fastened at the floor and ceiling with wood screws into the
structure.
4. Minor lighting and mechanical revisions may occur and will be handled under the
appropriate permit.
Please feel free to contact the office at 425 - 333 -4797 with any further questions or clarifications.
Respectfully,
P.O. BOX 995 Carnation, WA 98014 P. 425.333.4797 1 F. 425.549.0163 1 C. 425.681.1070
Construction • Management • Consultation
•
City of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
February 18, 2010
Jesse C Zeigler
PO Box 995
Carnation, WA 98014
RE: Incomplete Letter #1
Development Permit Application D10 -041
Otis Elevator —13035 Gateway Dr
Dear Mr. Zeigler,
This letter is to inform you that your permit application received at the City of Tukwila Permit Center on
February 12, 2010 is determined to be incomplete. Before your application can continue the plan review
process the attached /following items from the following department(s) need(s) to be addressed:
Building Department: Allen Johannessen at 206 433 -7163 if you have any questions
concerning the attached comments.
Please address the comment above in an itemized format with applicable revised plans,
specifications, and /or other documentation. The City requires that four (4) sets of revised plans,
specifications and /or other documentation be resubmitted with the appropriate revision block.
In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every
resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will
not be accepted through the mail or by a messenger service.
If you have any questions, please contact me at the Permit Center at (206) 431 -3670.
Sincerely,
AILQ et/le\■Q/r
Bill Rambo
Permit Technician
Enclosures
File: D10 -041
W: \Permit Center \Incomplete Letters\2010\D10 -041 Incomplete Ltr 4 1.DOC
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
•
Tukwila Building Division
Allen Johannessen, Plan Examiner
Determination of Completeness Memo
Date: February 18, 2010
Project Name: Otis Elevator Company
Permit #: D10 -041
Plan Review: Allen Johannessen, Plans Examiner
The Building Division has deemed the subject permit application incomplete. To assist the applicant in
expediting the Department plan review process, please forward the following comments.
(GENERAL NOTE)
PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size).
(If applicable) Structural Drawings and structural calculations sheets shall be original signed wet
stamped, not copied.)
L Provide plans drawn to scale. Reduced plan sheets shall not be sufficient for review.
2. Highlight the area of work. Identify that which is existing and which is new construction.
3. Provide building type of construction information. Include details to identify all elements and
materials used in the new construction and show method of securing new construction to existing
building floor and ceiling.
4. Identify any alterations that may apply to ceiling systems or other building elements to include
lighting, ventilation etc.
Should there be questions concerning the above requirements, contact the Building Division at 206 -431-
3670. No further comments at this time.
• AERMIT000 COPY
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D10 -041 DATE: 02/26/10
PROJECT NAME: OTIS ELEVATOR
SITE ADDRESS: 13035 GATEWAY DR
Original Plan Submittal
Response to Correction Letter #
X Response to Incomplete Letter # 1
Revision # after Permit Issued
DEPARTMENT )-1O
4uitding 440on •
Public Works ❑
r/1
ire Prevention
Structural
Planning Division
❑ Permit Coordinator
n
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete Kt -
Comments:
Incomplete ❑
DUE DATE: 03/02/10
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES/THURS ROUTING:
Building
Please Route Structural Review Required _ No further Review Required n
REVIEWER'S INITIALS:
DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 03/30/10
Approved n Approved with Conditions Not Approved (attach comments)
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections:
Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents routing slip.doc
2 -28 -02
f PERMITCOORDCOPYr
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D10 -041 DATE: 02/11/10
PROJECT NAME: OTIS ELEVATOR COMPANY
SITE ADDRESS: 13035 GATEWAY DR, STE 157
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # Revision # after Permit Issued
DEPART ENTS•
tlTlding i ion
0
Pub lic Wo ks
\revention
A-,JC, :2-I d
Structural
alt
Plantning DivlJ4 l�
nPermit Coordinator ❑
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete ❑
Comments:
Incomplete xf
DUE DATE: 02/16/10
Not Applicable
Permit Center Use Only 1 _ 0 INCOMPLETE LETTER MAILED: o" 0 LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Building
Please Route ❑
REVIEWER'S INITIALS:
Structural Review Required ❑ No further Review Required n
DATE:
APPROVALS OR CORRECTIONS:
Approved n Approved with Conditions ❑ Not Approved (attach comments) n
Notation:
REVIEWER'S INITIALS:
DUE DATE: 03/16/10
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
•
City of Tukwila
Steven M. Mullet, Mayor
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Steve Lancaster, Director
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
Date: 9 -d`10. IC)
Plan Check/Permit Number: D 10 -041
® Response to Incomplete Letter # 1
❑ Response to Correction Letter #
❑ Revision # after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
Project Name: Otis Elevator
Project Address: 13035 Gateway Dr
CITY OF 7'1 JUI
FEB 2 6 2010
PERMIT CENTER
Contact Person: Ze eX Phone Number: _ 4?-S-
Summary of Revision:
\ease d cam\ �. C\a r-` ct 'w ' k- cecr.
r\ es
ArecAS c O e cIv`ic \e 0, -. fp
U OL\\ 0 n S 00-‘D "''v(xe—%
U : ,`if?`_
Sheet Number(s):
"Cloud" or highlight all areas of revision including date of revision
Received at the City of Tukwila Permit Center by:
Entered in Permits Plus on 07,
\applications \forms- applications on line\revision submittal
Created: 8 -13 -2004
Revised:
Contractors or Tradespeople Peter Friendly Page
•
General /Specialty Contractor
A business registered as a construction contractor with L &I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name R C Zeigler Co Inc UBI No. 600442150
Phone 4253334797 Status Active
Address Pob 995 License No. RCZEICI183MN
Suite /Apt. License Type Construction Contractor
City Carnation Effective Date 7/15/1982
State Wa Expiration Date 7/25/2011
Zip 98014 Suspend Date
County King Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
ZEIGLCC223QB
Zeigler Construction
Company
Construction
Contractor
General
Unused
11/2/1978
7/15/1989
Archived
Business Owner Information
Name
Role
Effective Date
Expiration Date
Zeigler, Richard C
President
07/15/1982
Bond Amount
Zeigler, Muriel A
Vice President
07/15/1982
KC3552
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
4
TRAVELERS CAS &
STY CO OF AMER
KC3552
07/15/2006
Until Cancelled
$12,000.0004/10
/2006
3
ST PAUL FIRE &
MARINE INS CO
KC3552
07/15/2002
07/15/2006
$12,000.0007/25
/2002
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
22
NAVIGATORS
SPEC INS
SE06CGL00366303
07/15/2007
07/15/2010
$1,000,000.0007
/09/2009
21
NIC INS CO
SE06CL003663 00
07/15/2006
07/15/2007
$1,000,000.00
07/13/2006
20
NAVIGATORS
INS CO
GNW500004
07/15/2005
07/15/2006
$1,000,000.00
07/07/2005
19
OOHIO CAS INS
BK0552976522
07/15/2004
07/15/2005
$1,000,000.0007
/15/2004
18
0010 CAS INS
BK052976522
07/15/2003
07/15/2004
$1,000,000.0007
/12/2004
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
https://fortress.wa.gov/lni/bbip/Print.aspx
03/04/2010
-xis'
EXIST. WOOD JOiSTS,
00140 E TOPPING
PLYWOROet AND Mez
cte lir fr.ir
SEPARATE PERMIT
REQUIRED FOR:
jethanioal
OlrElectrIcal
lumbIng
Cirbas Piping
City of Tukwila
BUILDING DIVISION
ON ROLES
EXIST, FLOOR TO GEEING
CABIN 41. WI SPED/ES
FELE C410PY
I) • r
Penult No
Plan review approval is subject t • OfMIS and ongssIons.
Approval of construction docum ,nts does not authorize
the violation of any adopted cod: or ordinance. Receipt
ol approv • - = t ons Is acknowledged:
roip
Office
Resource
IMMIN IMMO
11111111111111 1111111111M
IMMO 1011/11M
IIIIIMM.•
nimai MN=
MINIM MIME
EXIST. 6" IN001
STD, 14!)1/1
%V/ R.19 INSLILA ION
EXISTV WOOD I
STDAALLS
MST. SEED
f PANTED WALLS
(EXPOSED DEVI
SEMI HEATED
R
No changes shall made to the scope
of work witho prior approval of
Tukwila Bui ding Division.
Will re uirp, a new plan submittal
EXIST, Lavv WALT° V.4"
C CARPLT
Ek*EXIST V=NEIN VCr
EP— tot EPDXY PAINT
f. PRIOR TO PERFORMING ANY DEMOLMOIV ACTIVITIES ALL CONTRACTORS
SHALL VERIFY ALL INTERIOR FIELD CONDITIONS AT THE SITE AND NOTIFY
MANAGEMENT OF ANY DISCREPANCIES ON THE DRAWINGS.
a COORDINATE ALL DEMOLITION ACTIVITY WITH BUILDING
OWNER/MANAGEMENT
9, PROTECT ALL EXISTING WINDOWS AND DOORS DURING DEMOLITION,
REPLACE AS REQUIRED IF DAMAGED.
1, COORDINATE ALL DEMOLITION WITH CONSTRUCTION,
POWER/TELEPHONE/DATA, AND FURNITURE/EQUIPMENT PLANS,
5.. DEMOLISH EXISTING WALLS, DOORS, DOORFRAMES, COAT RODS, MILLWORK
AND ELECTRIC DEVICES IN AREAS DESIGNATED ON DEMOLITION PLAN,
5. PATCH AND R ,EF'AIR ALL CEILING, WALL, COLUMN ENCLOSURES, AND FLOORS
AS REQUIRED, MAKE READY FOR NEW FINISHE„S TO MATCH EXISTING
ADJACENT FIAIISHES.
?, CONTRACTOR TO PROVIDE FOR CONTINUOUS OPERATION OF ALL, BUILDING
SECURITY, FIRE ALARM AND FIRE SUPPRESSION SYSTEMS DURING THE
COURSE OF DEMOLITION WORK,
9. ALL EXISTING SURFACES TO REMAIN ARE TO BE PROTECTED THROUGHOUT
CONSTRUCTION.,
9, RELOCATE GE/LING ITEMS INCLUDING LIGHTING, HVAC DIFFUSERS AND
RETURN GRILLS TO PROVIDE A COMPLETE AND COORDINATED PLAN.
.01, REMOVE AND DISCARD ALL EXISTING CARPETING THROUGHOUT THE ENTIRE
OFFICE AREA.. REMOVE ANY GLUE RESIDUE FROM SUBSTRATE, .FLASH PATCH
SUBSTRATE IN AREAS RECEIVING NEW FLOOR FINISH TO CREATE A SMOOTH
LEVEL SURFACE FREE OF ANY DEBRIS .AND DEFECTS FOR NEW FINISHES,
(1) IN EXISTING BUILT OUT OFFICE AREA REMOVE WALL SECTIONS. REPAIR
PERPENDICULAR WALL SURFACES TO !WATCH ADJACENT CONSTRUCTION
AND PREPARE FOR NEW FINISHES. SEE GENERAL DEMOLITION NOTE 5.
C) REMOVE SAFETY RAILING AT EXISTING MEZZANINE EDGE.
6) IN EXISTING TOILET ROOM, REMOVE EXISTING MILLWORK, AND PLUMBING
":" FIXTURES, PATCH AND REPAIR WALLS, AND FLOOR FOR A PROFESSIONAL
FINISH,
FOUR !ARM SPRINGS
FAluilsoTON, Cv 00082
PRIOR TO PERFORMING ANY CONSTRUCTION ACTIVITIES ALL CONTRACTORS
SHALL VERIFY ALL FIELD CONDITIONS AT THE SITE AND NOTIFY TENANT OF
ANY DISCREPANCIES ON THE DRAWINGS,
2, REUSE EXISTING DOOR IF POSSIBLE, NEW DOORS SHALL MATCH BUILDING
STANDARD AND BE FINISHED TO MATCH EXISTING SURROUNDING
CONDITIONS.
a PROVIDE AND INSTALL ALLAPPLICABLE HARDWARE TO THOSE DOORS
INDICATED AS' HAVING LOOK...PROVIDE SEPARATE KEYING FOR THE OFFICE
ANO MEZZANINE/WAREHOUSE. SPACES ON A COMMON MASTER KEY SYSTEM.
PROVIDE (2) SETS OF KEYS TO EACH LOCK TO TENANT. TIOCK INDICATES
PRIVACY SET
4* REPLACE EXISTING SHEET VINYL FLOORING IN MEN'S AND WOMEN'S ROOM
WITH NEW VCT PROVIDE AND INSTALL CARPETING FOR ALL OTHER OFFICE
AREA SPACES. TENANT TO SELECT COLORS FOR VCT AND CARPET,
5. MODIFY, REPLACE OR SUPPLEMENT EXISTING HVAC SYSTEM AS REQUIRED
• TO ACCOMMODATE NEW SPACE USAGE* PROVIDE ALL NECESSARY
DESIGN,ENGINEE13ING SERVICES REWIRED TO EVALUATE EXISTING HVAC
SYSTEM IN ORDER TO DELIVER A COMPLETE SOLUTION IN SUPPORT OF THE
NEW LAYOUT, ALL WORK SHALL MEET OUTLINE PERFORMANCE
SPECIFICATIONS AND ALL APPLICABLE CODES.
6. PROVIDE AND INSTALL ALL NECESSARY WOOD BLOCKING, NAILERS AND
FURRING REQUIRED FOR MOUNTING TOILET ACCESSORIES, AND SYSTEMS
FURNITURE WHERE REQUIRED,
PAINTALL IST FL. EXIST, TOILET RMS, (S. NEW CONSTRUCTION AS SPECIFIED..
8. CLEAN/REPLACE ANY AGED OR DAMAGED CEILING TILES OR GRID.
9* RELOCATE AND ADD Lia.H7 FIXTURES,. DIFFUSERS, SPRINKLEFI HEADS, ETC.,
FOR COCOPLETE AND COORDINATED INSTALLATION,
10, EXISTING LIGHT FIXTURES THROUGHOUT INTERIOR BUILDING AND LOADING
DOCK AREA TO SE IN GOOD WORKING CONDITION,
ADD/REPAIR/REPLACE/RELOCATE OR ADJUST AS NEEDED TO
ACCOMMODATE NEW LAYOUT AND MEET ALL APPLICABLE CODE
REQUIREMENTS AS WELL AS SPECIFIC.ATIONS.
I I. ALL ELECTRICAL, MECHANICAL, PLUMBING, SPRINKLER SYSTEMS TO BE
CODE COMPLIANT AND IN GOOD WORKING ORDER.
KEYED CONSTRUCTION NOTES:
Open Officv
Office
TAM ARE4
AREA CALCULATIONS:
USEABLE TOTAL SF 9,111
WAREHOUSE SF 1,508
OFFICE 1ST FL SF 3,647
OFFICE 2ND FL •SF 2,259
MEZZANINE SF 913
TRAINING $F 730
CAPACITY 37
OFFICE SF/CAP, 160
IMEN4S ROOM AND WOMEN`S ROOM TO BE ADA CONIPLIANT PROVIDE AND
INSTALL ADA COMPLIANT FIXTURES, GRAB BARS AND ALL STANDARD
ACCESSORIES,
FEB 2 6 2010
PERMIT CENTER
Suite 157113035 Gateway Dr.
Tukwila, WA 981684396
Move Add Change Package
1AT PRIVATE OFFICE 207, RETURN INTERIOR OFFICE PARTITION TO NEAREST
EXTERIOFI WIAIDOW MULLION.
1NEW SEPARATION WALLS BETWEEN OFFICE SPACES AND
MEZZANINE/WAREHOUSE SPACES SHALL BE EXTENDED TO THE UNDERSIDE
OF THE DECK ABOVE WITH SOUND ATTENUATION INSULATION FROM TOP TO
BOTTOM, AND CONSTRUCTED TO MEET CODE REQUIREMENTS,
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAR 0 2 2910
ArS
City ot Tukwila
BUILDING DIVISION
PROVIDE AND INSTALL 34-0W X 4P-0"H WINDOW SILL TO BE AT 3*-0" AFF.
RELOCATE EXISTING GE/LING SLOT FOR EXISTING RECESSED PROJECTOR
SCREEN, MODIF'Y CEILING GRID AND TILES ACCORDINGLY,
AREA, Jr113 tir
Demolition/Construction
J PROVIDE AND INSTALL NEW WALL CONSTRUCTION AT FORMER DOOR OPENING, PROVIDE METAL
STUD CONSTRUCTION, INSULATE COMPLETELY AND PROVIDE GYPSUM BOARD BOTH SIDES.
1PROVIDE AND INSTALL 12'Wx12"H VISION PANEL
WAREHOUSE 105 DOOR TO OPEN OFFICE 102
PRAWN fAe
An
etitEtt.
CI-IMMO BY:
bag:
PM
1 2/1) 8)2009